MIBs Depot

PT-RADIOLINK-MIB

Registered at
1.3.6.1.4.1.193.223.2.7
Last updated
2017-12-01 16:00
Organization
Ericsson
Revisions
2017-12-01 16:00, 2017-04-05 10:00, 2017-01-18 10:00, 2016-12-06 14:00, 2016-05-22 10:30
Namespace
ericsson
Source file
PT-RADIOLINK-MIB
Digest
sha256:ff546dd6936b46b58b30d036bfec14b6c138b030d7310dc711ea71be2407e05c

Description

This is the MIB for Radio Link specifics in PT

Contact

Anders Ekvall Postal: Ericsson AB, E-Mail: anders.ekvall@ericsson.com

Imports

FromSymbols
IF-MIBifEntry
INET-ADDRESS-MIBInetAddressIPv6
PT-MIBpt
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
INET-ADDRESS-MIB
MINI-LINK-MIB
PT-MIB
PT-RADIOLINK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
AcmTC
TEXTUAL-CONVENTION
An integer which indicates the ACM.
current
EnableStatusTC
TEXTUAL-CONVENTION
An integer which indicates the enabled status.
current
XpicMimoTC
TEXTUAL-CONVENTION
An integer which indicates the XPIC or MIMO status.
current

Objects

NameOIDSyntaxAccessStatus
ctTable
OBJECT-TYPE
A table of CT Table entries.
1.3.6.1.4.1.193.223.2.7.1not-accessiblecurrent
ctEntry
OBJECT-TYPE
An entry of CT application.
1.3.6.1.4.1.193.223.2.7.1.1not-accessiblecurrent
actualInputPower
OBJECT-TYPE
Actual input power of the CT in dBm
1.3.6.1.4.1.193.223.2.7.1.1.1OCTET STRINGread-onlycurrent
actualOutputPower
OBJECT-TYPE
Actual output power of the CT in dBm
1.3.6.1.4.1.193.223.2.7.1.1.2OCTET STRINGread-onlycurrent
actualRxAcm
OBJECT-TYPE
Actual rx modulation and coding
1.3.6.1.4.1.193.223.2.7.1.1.3OCTET STRINGread-onlycurrent
actualTxAcm
OBJECT-TYPE
Actual tx modulation and coding
1.3.6.1.4.1.193.223.2.7.1.1.4OCTET STRINGread-onlycurrent
ctDistinguishedName
OBJECT-TYPE
Unique id/name of the carrier termination, according to FDN (rack/slot/port/class)
1.3.6.1.4.1.193.223.2.7.1.1.5OCTET STRINGread-onlycurrent
description
OBJECT-TYPE
User description of the carrior termination.
1.3.6.1.4.1.193.223.2.7.1.1.6OCTET STRINGread-writecurrent
carrierId
OBJECT-TYPE
Id of the carrier. (A, B, C, D) Used in XPIC & MIMO configurations to check that the carrier termination is connected to the correct far end carrier termination. Should be the same id on both sides of the hop. Defaulted when not MIMO or XPIC. Sometimes also referred to as preamble
1.3.6.1.4.1.193.223.2.7.1.1.7INTEGER {a(1), b(2), c(3), d(4), unknown(5)}read-writecurrent
ctStatus
OBJECT-TYPE
The status of the carrier termination, hop
1.3.6.1.4.1.193.223.2.7.1.1.8INTEGER {down(1), up(2), na(3), unknown(4), degraded(5)}read-onlycurrent
frameId
OBJECT-TYPE
A unique identifier for the radio frame to be used. Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination.
1.3.6.1.4.1.193.223.2.7.1.1.9Integer32 (0..10000)read-writecurrent
txFrequency
OBJECT-TYPE
Selected frequency on the transmitter (kHz). Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination.
1.3.6.1.4.1.193.223.2.7.1.1.10Integer32read-writecurrent
minTxFrequency
OBJECT-TYPE
Minimum Tx frequency possible to use, given by the selected frame-id
1.3.6.1.4.1.193.223.2.7.1.1.11Integer32read-onlycurrent
maxTxFrequency
OBJECT-TYPE
Maximum Tx frequency possible to use, given by the selected frame-id
1.3.6.1.4.1.193.223.2.7.1.1.12Integer32read-onlycurrent
rxFrequency
OBJECT-TYPE
Selected frequency on the receiver (kHz). Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination.
1.3.6.1.4.1.193.223.2.7.1.1.13Integer32read-writecurrent
minRxFrequency
OBJECT-TYPE
Minimum Rx frequency possible to use, given by the selected frame-id
1.3.6.1.4.1.193.223.2.7.1.1.14Integer32read-onlycurrent
maxRxFrequency
OBJECT-TYPE
Maximum Rx frequency possible to use, given by the selected frame-id
1.3.6.1.4.1.193.223.2.7.1.1.15Integer32read-onlycurrent
frequencyStepSize
OBJECT-TYPE
Frequency step size in kHz
1.3.6.1.4.1.193.223.2.7.1.1.16Integer32read-onlycurrent
duplexDistance
OBJECT-TYPE
Distance between Tx and Rx frequencies (kHz)
1.3.6.1.4.1.193.223.2.7.1.1.17Integer32read-onlycurrent
duplexType
OBJECT-TYPE
The duplex type is given by the equipment (Fixed,Variable)
1.3.6.1.4.1.193.223.2.7.1.1.18INTEGER {variable(1), fixed(2), unknown(3)}read-onlycurrent
duplexConfig
OBJECT-TYPE
Enabling or disabling configuration of Rx freq using duplex distance
1.3.6.1.4.1.193.223.2.7.1.1.19EnableStatusTCread-writecurrent
autoFreqSelection
OBJECT-TYPE
Automatic frequency selection mode
1.3.6.1.4.1.193.223.2.7.1.1.20INTEGER {disabled(1), master(2), slave(3), unknown(4)}read-writecurrent
autoFreqSelectedChannel
OBJECT-TYPE
Automatic frequency selected channel
1.3.6.1.4.1.193.223.2.7.1.1.21Integer32read-writecurrent
autoFreqSelectionStatus
OBJECT-TYPE
Automatic frequency status
1.3.6.1.4.1.193.223.2.7.1.1.22INTEGER {idle(1), searchingForSlave(2), requestingInfoFromSlave(3), waitingForMaster(4), waitingForChannelInfoRequest(5), inProgress(6), initializing(7), finished(8), failed(9), unknown(10)}read-onlycurrent
channelSpacing
OBJECT-TYPE
Channel spacing
1.3.6.1.4.1.193.223.2.7.1.1.23INTEGER {cs7MHz(1), cs10MHz(2), cs14MHz(3), cs20MHz(4), cs28MHz(5), cs30MHz(6), cs40MHz(7), cs50MHz(8), cs56MHz(9), cs250MHz(10), cs60MHz(11), cs500MHz(12), cs750MHz(13), cs100MHz(14), cs150MHz(15), cs200MHz(16), cs125MHz(17), cs80MHz(18), cs112MHz(19), cs1000MHz(20), cs1250MHz(21), cs1500MHz(22), cs62p5MHz(23), cs2000MHz(24), unknown(25)}read-onlycurrent
polarization
OBJECT-TYPE
Antenna polarization
1.3.6.1.4.1.193.223.2.7.1.1.24INTEGER {notSpecified(1), horizontal(2), vertical(3), unknown(4)}read-writecurrent
txOperStatus
OBJECT-TYPE
Operative status of the transmitter
1.3.6.1.4.1.193.223.2.7.1.1.25INTEGER {unknown(1), off(2), on(3), standby(4)}read-onlycurrent
txAdminStatus
OBJECT-TYPE
Administrative status of the transmitter
1.3.6.1.4.1.193.223.2.7.1.1.26INTEGER {off(1), on(2), unknown(3)}read-writecurrent
selectedOutputPowerType
OBJECT-TYPE
Selected output power type
1.3.6.1.4.1.193.223.2.7.1.1.27INTEGER {standard(1), high(2), unknown(3)}read-writecurrent
availableOutputPowerType
OBJECT-TYPE
Available output power type
1.3.6.1.4.1.193.223.2.7.1.1.28INTEGER {standard(1), high(2), unknown(3)}read-writecurrent
selectedMinOutputPower
OBJECT-TYPE
Selected min output power. Selected min & max output power should be set to the same value for RTPC mode, otherwise the hop operates in ATPC mode.
1.3.6.1.4.1.193.223.2.7.1.1.29Integer32read-writecurrent
selectedMaxOutputPower
OBJECT-TYPE
Selected max output power. Selected min & max output power should be set to the same value for RTPC mode, otherwise the hop operates in ATPC mode.
1.3.6.1.4.1.193.223.2.7.1.1.30Integer32read-writecurrent
availableMinOutputPower
OBJECT-TYPE
The minimum output power supported (dBm). The system shows a value if the equipment is available and a frame id has been selected.
1.3.6.1.4.1.193.223.2.7.1.1.31Integer32read-onlycurrent
availableMaxOutputPower
OBJECT-TYPE
The maximum output power supported (dBm). The system shows a value if the equipment is available and a frame id has been selected.
1.3.6.1.4.1.193.223.2.7.1.1.32Integer32read-onlycurrent
referenceSec
OBJECT-TYPE
Each modulation is compliant to a Reference Spectrum Efficiency Class (RSEC). When running Adaptive Coding/Modulation, one SEC has to be selected for all the coding/modulations between selectedMinACM and selectedMaxACM. This parameter is called Reference SEC. This setting will affect availableMaxOutputPower, in order to fulfill spectrum requirements. Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination.
1.3.6.1.4.1.193.223.2.7.1.1.33INTEGER {noAvailable(1), sec2(2), sec4L(4), sec4H(5), sec5B(7), sec6B(9), sec5LB(10), sec5HB(11), sec6LB(12), sec6HB(13), sec7B(14), unknown(15)}read-writecurrent
targetInputPowerFarEnd
OBJECT-TYPE
The wanted input power at far end (dBm), when running ATPC
1.3.6.1.4.1.193.223.2.7.1.1.34Integer32read-writecurrent
berAlarmThreshold
OBJECT-TYPE
Threshold for the BER alarm
1.3.6.1.4.1.193.223.2.7.1.1.35INTEGER {tenExpMinus6(1), tenExpMinus3(2)}read-writecurrent
inputPowerAlarmThreshold
OBJECT-TYPE
Threshold for the input power alarm
1.3.6.1.4.1.193.223.2.7.1.1.36Integer32read-writecurrent
plannedAlignmentInputPower
OBJECT-TYPE
The planned received input power (dBm) dependent upon selected minimum ACM and corresponding output power. Used when doing alignment
1.3.6.1.4.1.193.223.2.7.1.1.37Integer32read-writecurrent
atpcFallback
OBJECT-TYPE
Enable or disable the output power fall back function
1.3.6.1.4.1.193.223.2.7.1.1.38EnableStatusTCread-writecurrent
atpcFallbackTimer
OBJECT-TYPE
Specifies the timer for output power fall back (# of seconds)
1.3.6.1.4.1.193.223.2.7.1.1.39Integer32read-writecurrent
atpcFallbackOutputPower
OBJECT-TYPE
The ATPC fallback output power
1.3.6.1.4.1.193.223.2.7.1.1.40Integer32read-writecurrent
xpicStatus
OBJECT-TYPE
Status of the XPIC function.
1.3.6.1.4.1.193.223.2.7.1.1.41XpicMimoTCread-onlycurrent
mimoStatus
OBJECT-TYPE
Status of the MIMO function.
1.3.6.1.4.1.193.223.2.7.1.1.42XpicMimoTCread-onlycurrent
actualSnir
OBJECT-TYPE
Actual signal to noise plus interference ratio (dB).
1.3.6.1.4.1.193.223.2.7.1.1.43OCTET STRINGread-onlycurrent
actualXpi
OBJECT-TYPE
The carrier to cross-polar interference level (dBc).
1.3.6.1.4.1.193.223.2.7.1.1.44OCTET STRINGread-onlycurrent
actualSi
OBJECT-TYPE
Spatial interference between the CTs when MIMO is configured.
1.3.6.1.4.1.193.223.2.7.1.1.45OCTET STRINGread-onlycurrent
actualTxCapacity
OBJECT-TYPE
Actual capacity supported by the carrier termination.
1.3.6.1.4.1.193.223.2.7.1.1.46Integer32read-onlycurrent
licensedCapacity
OBJECT-TYPE
Wanted or installed license for the capacity allowed for the carrier termination.
1.3.6.1.4.1.193.223.2.7.1.1.47Integer32read-onlycurrent
availableMinCapacity
OBJECT-TYPE
Minimum capacity possible to use. Given by the selected frame-id (kbit/s)
1.3.6.1.4.1.193.223.2.7.1.1.48Integer32read-onlycurrent
availableMaxCapacity
OBJECT-TYPE
Maximum capacity possible to use. Given by the selected frame-id (kbit/s)
1.3.6.1.4.1.193.223.2.7.1.1.49Integer32read-onlycurrent
selectedMinCapacity
OBJECT-TYPE
Selected minimum capacity, derived from selected minimum ACM (kbit/s)
1.3.6.1.4.1.193.223.2.7.1.1.50Integer32read-onlycurrent
selectedMaxCapacity
OBJECT-TYPE
Selected maximum capacity, derived from selected maximum ACM (kbit/s)
1.3.6.1.4.1.193.223.2.7.1.1.51Integer32read-onlycurrent
wantedLicensedCapacity
OBJECT-TYPE
Wanted licensed capacity and creation of LRF for the carrier termination (kbit/s)
1.3.6.1.4.1.193.223.2.7.1.1.52Integer32read-writecurrent
availableMinAcm
OBJECT-TYPE
Minimum ACM possible to use, given by the selected frame id.
1.3.6.1.4.1.193.223.2.7.1.1.53AcmTCread-onlycurrent
availableMaxAcm
OBJECT-TYPE
Maximum ACM possible to use, given by the selected frame id
1.3.6.1.4.1.193.223.2.7.1.1.54AcmTCread-onlycurrent
selectedMinAcm
OBJECT-TYPE
Selected minimum coding/modulation. If selectedMinACM = selectedMaxACM, then the modulation is fixed
1.3.6.1.4.1.193.223.2.7.1.1.55AcmTCread-writecurrent
selectedMaxAcm
OBJECT-TYPE
Selected maximum coding/modulation. If selectedMinACM = selectedMaxACM, then the modulation is fixed
1.3.6.1.4.1.193.223.2.7.1.1.56AcmTCread-writecurrent
actualRxAcmTC
OBJECT-TYPE
Actual rx modulation and coding
1.3.6.1.4.1.193.223.2.7.1.1.57AcmTCread-onlycurrent
actualTxAcmTC
OBJECT-TYPE
Actual tx modulation and coding
1.3.6.1.4.1.193.223.2.7.1.1.58AcmTCread-onlycurrent
alignmentMode
OBJECT-TYPE
Enable or disable the alignment mode
1.3.6.1.4.1.193.223.2.7.1.1.59EnableStatusTCread-writecurrent
rfLoop
OBJECT-TYPE
Enable or disable the rf loop
1.3.6.1.4.1.193.223.2.7.1.1.60EnableStatusTCread-writecurrent
ptRadioLinkConformance
OBJECT-IDENTITY
1.3.6.1.4.1.193.223.2.7.2
ptRadioLinkCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.193.223.2.7.2.1
ptRadioLinkGroups
OBJECT-IDENTITY
1.3.6.1.4.1.193.223.2.7.2.2
rltTable
OBJECT-TYPE
A table of RLT Table entries.
1.3.6.1.4.1.193.223.2.7.3not-accessiblecurrent
rltEntry
OBJECT-TYPE
An entry of RLT application.
1.3.6.1.4.1.193.223.2.7.3.1not-accessiblecurrent
rltDistinguishedName
OBJECT-TYPE
Unique id/name of the radio link termination, according to FDN (rack/slot/port/class)
1.3.6.1.4.1.193.223.2.7.3.1.1OCTET STRINGread-onlycurrent
neIpAddress
OBJECT-TYPE
NE IP address
1.3.6.1.4.1.193.223.2.7.3.1.2IpAddressread-onlycurrent
neIpv6Address
OBJECT-TYPE
NE IP V6 address
1.3.6.1.4.1.193.223.2.7.3.1.3InetAddressIPv6read-onlycurrent
neName
OBJECT-TYPE
NE Name
1.3.6.1.4.1.193.223.2.7.3.1.4OCTET STRINGread-onlycurrent
neType
OBJECT-TYPE
NE Type
1.3.6.1.4.1.193.223.2.7.3.1.5INTEGER {unknown(1), mle(2), xfMle(3), tn(4), cn(5), pt(6)}read-onlycurrent
id
OBJECT-TYPE
User defined id of the radio link terminal
1.3.6.1.4.1.193.223.2.7.3.1.6OCTET STRINGread-writecurrent
rltStatus
OBJECT-TYPE
The status of the radio link terminal
1.3.6.1.4.1.193.223.2.7.3.1.7INTEGER {down(1), up(2), na(3), unknown(4), degraded(5)}read-onlycurrent
mode
OBJECT-TYPE
The status of the radio link terminal
1.3.6.1.4.1.193.223.2.7.3.1.8INTEGER {mode1plus0(1), mode1plus1CSB(2), mode1plus1RLP(3), mode2plus0RLB(4), mode2plus1CSB(5), mode2plus1RLP(6), mode2plus2CSB(7), mode2plus2RLP(8), mode3plus0RLB(9), mode4plus0RLB(10), notAvailable11(11), notAvailable12(12), notAvailable13(13), notAvailable14(14), mode3plus1RLP(15), mode3plus2RLP(16), mode3plus3RLP(17), mode4plus1RLP(18), mode4plus2RLP(19), mode4plus3RLP(20), mode4plus4RLP(21), notAvailable22(22), notAvailable23(23), notAvailable24(24), notAvailable25(25), notAvailable26(26), notAvailable27(27), mode3plus1CSB(28), mode3plus2CSB(29), mode3plus3CSB(30), mode4plus1CSB(31), mode4plus2CSB(32), mode4plus3CSB(33), mode4plus4CSB(34), unknown(35)}read-writecurrent
actualTxTotalCapacity
OBJECT-TYPE
Actual aggregated total (packet + TDM) transmitter capacity for the radio link termination. Limited by licenses & configuration (=nearEndLimitedCapacity) and depending on actual modulation/coding used at the moment.
1.3.6.1.4.1.193.223.2.7.3.1.9Integer32read-onlycurrent
limitedTotalCapacity
OBJECT-TYPE
Maximum total capacity allowed by the current configuration and installed licenses. Aggregated from the constituent carrier termination values.
1.3.6.1.4.1.193.223.2.7.3.1.10Integer32read-onlycurrent
protectionStatus
OBJECT-TYPE
Status of a protected node.
1.3.6.1.4.1.193.223.2.7.3.1.11INTEGER {unprotected(1), protected(2), unableToProtect(3), unknown(4)}read-onlycurrent
revertiveWaitToRestore
OBJECT-TYPE
The time, in number of seconds, to wait before switching back to the preferred Tx.
1.3.6.1.4.1.193.223.2.7.3.1.12Integer32read-writecurrent
revertivePreferredTx
OBJECT-TYPE
The preferred carrier termination transmitter.
1.3.6.1.4.1.193.223.2.7.3.1.13INTEGER {ct11(1), ct12(2), ct21(3), ct22(4), notApplicable(5), unknown(6)}read-writecurrent
protectionSwitchMode
OBJECT-TYPE
.The mode in which the switching mechanism is configured
1.3.6.1.4.1.193.223.2.7.3.1.14INTEGER {auto(1), manual(2), autoAndRevertive(3), unknown(4), notApplicable(5)}read-writecurrent
fadeNotificationTimer
OBJECT-TYPE
Notification is sent if fading is longer than this timer, applicable for protection.
1.3.6.1.4.1.193.223.2.7.3.1.15Integer32read-writecurrent
expectedFarEndId
OBJECT-TYPE
Expected id of far-end terminal
1.3.6.1.4.1.193.223.2.7.3.1.16OCTET STRINGread-writecurrent
farEndIdCheck
OBJECT-TYPE
Enabling of far end id check.
1.3.6.1.4.1.193.223.2.7.3.1.17INTEGER {enabled(1), disabled(2), unknown(3)}read-writecurrent
cpriMode
OBJECT-TYPE
Set the mode of the CPRI front-haul product.
1.3.6.1.4.1.193.223.2.7.3.1.18INTEGER {master(1), slave(2), notApplicable(3), unknown(4)}read-writecurrent
cpriStatus
OBJECT-TYPE
The status of the CPRI front-haul product.
1.3.6.1.4.1.193.223.2.7.3.1.19INTEGER {idle(1), waitingOnRtcSync(2), waitingOnCpri(3), waitingOnRxRequest(4), waitingOnTxRequest(5), inSync(6), unknown(7)}read-onlycurrent
manualSwitch
OBJECT-TYPE
Manual switch of protected carrier termination transmitter.
1.3.6.1.4.1.193.223.2.7.3.1.20INTEGER {ct11(1), ct12(2), ct21(3), ct22(4), notApplicable(5), unknown(6)}read-writecurrent
mlhcOperStatus
OBJECT-TYPE
Operative status of multi layer header compression.
1.3.6.1.4.1.193.223.2.7.3.1.21INTEGER {up(1), down(2), unknown(3)}read-onlycurrent
mlhcAdminStatus
OBJECT-TYPE
Administrative status of multi layer header compression.
1.3.6.1.4.1.193.223.2.7.3.1.22INTEGER {off(1), on(2), unknown(3)}read-writecurrent
mlhcMplsConfig
OBJECT-TYPE
MLHC/MPLS configuration.
1.3.6.1.4.1.193.223.2.7.3.1.23INTEGER {controlWord(1), l2(2), l3(3), mplsOnly(4), unknown(5)}read-writecurrent
plcOperStatus
OBJECT-TYPE
Operative status of payload compression.
1.3.6.1.4.1.193.223.2.7.3.1.24INTEGER {up(1), down(2), unknown(3)}read-onlycurrent
plcAdminStatus
OBJECT-TYPE
Administrative status of payload compression.
1.3.6.1.4.1.193.223.2.7.3.1.25INTEGER {off(1), on(2), unknown(3)}read-writecurrent
ctPerformance
OBJECT-IDENTITY
1.3.6.1.4.1.193.223.2.7.4
ctG826ContinuousTable
OBJECT-TYPE
A table of CT G826 Performance Continuous counters entries. The counters are reset by ctG826Reset
1.3.6.1.4.1.193.223.2.7.4.1not-accessiblecurrent
ctG826ContinuousEntry
OBJECT-TYPE
An entry of CT G826 Performance Continuous counters.
1.3.6.1.4.1.193.223.2.7.4.1.1not-accessiblecurrent
ctG826TimeElapsed
OBJECT-TYPE
Time elapsed in seconds since last PMReset
1.3.6.1.4.1.193.223.2.7.4.1.1.1Counter32read-onlycurrent
ctBBE
OBJECT-TYPE
Background Block Errors
1.3.6.1.4.1.193.223.2.7.4.1.1.2Counter32read-onlycurrent
ctBBER
OBJECT-TYPE
Background Block Errors Ratio
1.3.6.1.4.1.193.223.2.7.4.1.1.3OCTET STRINGread-onlycurrent
ctES
OBJECT-TYPE
Error seconds
1.3.6.1.4.1.193.223.2.7.4.1.1.4Counter32read-onlycurrent
ctESR
OBJECT-TYPE
Error seconds Ratio
1.3.6.1.4.1.193.223.2.7.4.1.1.5OCTET STRINGread-onlycurrent
ctSES
OBJECT-TYPE
Severely error seconds
1.3.6.1.4.1.193.223.2.7.4.1.1.6Counter32read-onlycurrent
ctSESR
OBJECT-TYPE
Severely error seconds Ratio
1.3.6.1.4.1.193.223.2.7.4.1.1.7OCTET STRINGread-onlycurrent
ctBB
OBJECT-TYPE
Background blocks
1.3.6.1.4.1.193.223.2.7.4.1.1.8OCTET STRINGread-onlycurrent
ctUAS
OBJECT-TYPE
Unavailable seconds
1.3.6.1.4.1.193.223.2.7.4.1.1.9Counter32read-onlycurrent
ctG826Reset
OBJECT-TYPE
Reset the continuous PM counters
1.3.6.1.4.1.193.223.2.7.4.1.1.10INTEGER {other(1), noReset(2), reset(3)}read-writecurrent
ctG826Current15mTable
OBJECT-TYPE
A table of CT Performance G826 15 m current counters Table entries.
1.3.6.1.4.1.193.223.2.7.4.2not-accessiblecurrent
ctG826Current15mEntry
OBJECT-TYPE
An entry of CT Performance G826 15 m current Table counters.
1.3.6.1.4.1.193.223.2.7.4.2.1not-accessiblecurrent
ctG826Current15mTimeElapsed
OBJECT-TYPE
Time elapsed in seconds since last PMReset
1.3.6.1.4.1.193.223.2.7.4.2.1.1Counter32read-onlycurrent
ctCurrent15mBBE
OBJECT-TYPE
Background Block Errors
1.3.6.1.4.1.193.223.2.7.4.2.1.2Counter32read-onlycurrent
ctCurrent15mBBER
OBJECT-TYPE
Background Block Errors Ratio
1.3.6.1.4.1.193.223.2.7.4.2.1.3OCTET STRINGread-onlycurrent
ctCurrent15mES
OBJECT-TYPE
Error seconds
1.3.6.1.4.1.193.223.2.7.4.2.1.4Counter32read-onlycurrent
ctCurrent15mESR
OBJECT-TYPE
Error seconds Ratio
1.3.6.1.4.1.193.223.2.7.4.2.1.5OCTET STRINGread-onlycurrent
ctCurrent15mSES
OBJECT-TYPE
Severely error seconds
1.3.6.1.4.1.193.223.2.7.4.2.1.6Counter32read-onlycurrent
ctCurrent15mSESR
OBJECT-TYPE
Severely error seconds Ratio
1.3.6.1.4.1.193.223.2.7.4.2.1.7OCTET STRINGread-onlycurrent
ctCurrent15mBB
OBJECT-TYPE
Background blocks
1.3.6.1.4.1.193.223.2.7.4.2.1.8Counter32read-onlycurrent
ctCurrent15mUAS
OBJECT-TYPE
Unavailable seconds
1.3.6.1.4.1.193.223.2.7.4.2.1.9Counter32read-onlycurrent
ctG826Current24hTable
OBJECT-TYPE
A table of CT Performance G826 Current 24h counters entries.
1.3.6.1.4.1.193.223.2.7.4.3not-accessiblecurrent
ctG826Current24hEntry
OBJECT-TYPE
An entry of CT Performance G826 Current 24 h counters.
1.3.6.1.4.1.193.223.2.7.4.3.1not-accessiblecurrent
ctG826Current24hTimeElapsed
OBJECT-TYPE
Time elapsed in seconds since last PMReset
1.3.6.1.4.1.193.223.2.7.4.3.1.1Counter32read-onlycurrent
ctCurrent24hBBE
OBJECT-TYPE
Background Block Errors
1.3.6.1.4.1.193.223.2.7.4.3.1.2Counter32read-onlycurrent
ctCurrent24hBBER
OBJECT-TYPE
Background Block Errors Ratio
1.3.6.1.4.1.193.223.2.7.4.3.1.3OCTET STRINGread-onlycurrent
ctCurrent24hES
OBJECT-TYPE
Error seconds
1.3.6.1.4.1.193.223.2.7.4.3.1.4Counter32read-onlycurrent
ctCurrent24hESR
OBJECT-TYPE
Error seconds Ratio
1.3.6.1.4.1.193.223.2.7.4.3.1.5OCTET STRINGread-onlycurrent
ctCurrent24hSES
OBJECT-TYPE
Severely error seconds
1.3.6.1.4.1.193.223.2.7.4.3.1.6Counter32read-onlycurrent
ctCurrent24hSESR
OBJECT-TYPE
Severely error seconds Ratio
1.3.6.1.4.1.193.223.2.7.4.3.1.7OCTET STRINGread-onlycurrent
ctCurrent24hBB
OBJECT-TYPE
Background blocks
1.3.6.1.4.1.193.223.2.7.4.3.1.8Counter32read-onlycurrent
ctCurrent24hUAS
OBJECT-TYPE
Unavailable seconds
1.3.6.1.4.1.193.223.2.7.4.3.1.9Counter32read-onlycurrent

Conformance

NameOIDStatus
ptRadioLinkFullCompliance
MODULE-COMPLIANCE
The compliance statement for SNMP entities which implement everything.
1.3.6.1.4.1.193.223.2.7.2.1.1current
ptRadioLinkCompleteGroup
OBJECT-GROUP
A collection of all current objects in this MIB module.
1.3.6.1.4.1.193.223.2.7.2.2.1current