PT-RADIOLINK-MIB
- Registered at
- 1.3.6.1.4.1.193.223.2.7
- Last updated
- 2017-12-01 16:00
- Organization
- Ericsson
- Revisions
- 2017-12-01 16:00, 2017-04-05 10:00, 2017-01-18 10:00, 2016-12-06 14:00, 2016-05-22 10:30
- Namespace
- ericsson
- Source file
PT-RADIOLINK-MIB- Digest
sha256:ff546dd6936b46b58b30d036bfec14b6c138b030d7310dc711ea71be2407e05c
Description
This is the MIB for Radio Link specifics in PT
Contact
Anders Ekvall Postal: Ericsson AB, E-Mail: anders.ekvall@ericsson.com
Imports
| From | Symbols |
|---|---|
| IF-MIB | ifEntry |
| INET-ADDRESS-MIB | InetAddressIPv6 |
| PT-MIB | pt |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB IF-MIB INET-ADDRESS-MIB MINI-LINK-MIB PT-MIB PT-RADIOLINK-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| AcmTC TEXTUAL-CONVENTION An integer which indicates the ACM. | current | |||
| EnableStatusTC TEXTUAL-CONVENTION An integer which indicates the enabled status. | current | |||
| XpicMimoTC TEXTUAL-CONVENTION An integer which indicates the XPIC or MIMO status. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ctTable OBJECT-TYPE A table of CT Table entries. | 1.3.6.1.4.1.193.223.2.7.1 | not-accessible | current | |
| ctEntry OBJECT-TYPE An entry of CT application. | 1.3.6.1.4.1.193.223.2.7.1.1 | not-accessible | current | |
| actualInputPower OBJECT-TYPE Actual input power of the CT in dBm | 1.3.6.1.4.1.193.223.2.7.1.1.1 | OCTET STRING | read-only | current |
| actualOutputPower OBJECT-TYPE Actual output power of the CT in dBm | 1.3.6.1.4.1.193.223.2.7.1.1.2 | OCTET STRING | read-only | current |
| actualRxAcm OBJECT-TYPE Actual rx modulation and coding | 1.3.6.1.4.1.193.223.2.7.1.1.3 | OCTET STRING | read-only | current |
| actualTxAcm OBJECT-TYPE Actual tx modulation and coding | 1.3.6.1.4.1.193.223.2.7.1.1.4 | OCTET STRING | read-only | current |
| ctDistinguishedName OBJECT-TYPE Unique id/name of the carrier termination, according to FDN (rack/slot/port/class) | 1.3.6.1.4.1.193.223.2.7.1.1.5 | OCTET STRING | read-only | current |
| description OBJECT-TYPE User description of the carrior termination. | 1.3.6.1.4.1.193.223.2.7.1.1.6 | OCTET STRING | read-write | current |
| carrierId OBJECT-TYPE Id of the carrier. (A, B, C, D) Used in XPIC & MIMO configurations to check that the carrier termination is connected to the correct far end carrier termination. Should be the same id on both sides of the hop. Defaulted when not MIMO or XPIC. Sometimes also referred to as preamble | 1.3.6.1.4.1.193.223.2.7.1.1.7 | INTEGER {a(1), b(2), c(3), d(4), unknown(5)} | read-write | current |
| ctStatus OBJECT-TYPE The status of the carrier termination, hop | 1.3.6.1.4.1.193.223.2.7.1.1.8 | INTEGER {down(1), up(2), na(3), unknown(4), degraded(5)} | read-only | current |
| frameId OBJECT-TYPE A unique identifier for the radio frame to be used. Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination. | 1.3.6.1.4.1.193.223.2.7.1.1.9 | Integer32 (0..10000) | read-write | current |
| txFrequency OBJECT-TYPE Selected frequency on the transmitter (kHz). Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination. | 1.3.6.1.4.1.193.223.2.7.1.1.10 | Integer32 | read-write | current |
| minTxFrequency OBJECT-TYPE Minimum Tx frequency possible to use, given by the selected frame-id | 1.3.6.1.4.1.193.223.2.7.1.1.11 | Integer32 | read-only | current |
| maxTxFrequency OBJECT-TYPE Maximum Tx frequency possible to use, given by the selected frame-id | 1.3.6.1.4.1.193.223.2.7.1.1.12 | Integer32 | read-only | current |
| rxFrequency OBJECT-TYPE Selected frequency on the receiver (kHz). Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination. | 1.3.6.1.4.1.193.223.2.7.1.1.13 | Integer32 | read-write | current |
| minRxFrequency OBJECT-TYPE Minimum Rx frequency possible to use, given by the selected frame-id | 1.3.6.1.4.1.193.223.2.7.1.1.14 | Integer32 | read-only | current |
| maxRxFrequency OBJECT-TYPE Maximum Rx frequency possible to use, given by the selected frame-id | 1.3.6.1.4.1.193.223.2.7.1.1.15 | Integer32 | read-only | current |
| frequencyStepSize OBJECT-TYPE Frequency step size in kHz | 1.3.6.1.4.1.193.223.2.7.1.1.16 | Integer32 | read-only | current |
| duplexDistance OBJECT-TYPE Distance between Tx and Rx frequencies (kHz) | 1.3.6.1.4.1.193.223.2.7.1.1.17 | Integer32 | read-only | current |
| duplexType OBJECT-TYPE The duplex type is given by the equipment (Fixed,Variable) | 1.3.6.1.4.1.193.223.2.7.1.1.18 | INTEGER {variable(1), fixed(2), unknown(3)} | read-only | current |
| duplexConfig OBJECT-TYPE Enabling or disabling configuration of Rx freq using duplex distance | 1.3.6.1.4.1.193.223.2.7.1.1.19 | EnableStatusTC | read-write | current |
| autoFreqSelection OBJECT-TYPE Automatic frequency selection mode | 1.3.6.1.4.1.193.223.2.7.1.1.20 | INTEGER {disabled(1), master(2), slave(3), unknown(4)} | read-write | current |
| autoFreqSelectedChannel OBJECT-TYPE Automatic frequency selected channel | 1.3.6.1.4.1.193.223.2.7.1.1.21 | Integer32 | read-write | current |
| autoFreqSelectionStatus OBJECT-TYPE Automatic frequency status | 1.3.6.1.4.1.193.223.2.7.1.1.22 | INTEGER {idle(1), searchingForSlave(2), requestingInfoFromSlave(3), waitingForMaster(4), waitingForChannelInfoRequest(5), inProgress(6), initializing(7), finished(8), failed(9), unknown(10)} | read-only | current |
| channelSpacing OBJECT-TYPE Channel spacing | 1.3.6.1.4.1.193.223.2.7.1.1.23 | INTEGER {cs7MHz(1), cs10MHz(2), cs14MHz(3), cs20MHz(4), cs28MHz(5), cs30MHz(6), cs40MHz(7), cs50MHz(8), cs56MHz(9), cs250MHz(10), cs60MHz(11), cs500MHz(12), cs750MHz(13), cs100MHz(14), cs150MHz(15), cs200MHz(16), cs125MHz(17), cs80MHz(18), cs112MHz(19), cs1000MHz(20), cs1250MHz(21), cs1500MHz(22), cs62p5MHz(23), cs2000MHz(24), unknown(25)} | read-only | current |
| polarization OBJECT-TYPE Antenna polarization | 1.3.6.1.4.1.193.223.2.7.1.1.24 | INTEGER {notSpecified(1), horizontal(2), vertical(3), unknown(4)} | read-write | current |
| txOperStatus OBJECT-TYPE Operative status of the transmitter | 1.3.6.1.4.1.193.223.2.7.1.1.25 | INTEGER {unknown(1), off(2), on(3), standby(4)} | read-only | current |
| txAdminStatus OBJECT-TYPE Administrative status of the transmitter | 1.3.6.1.4.1.193.223.2.7.1.1.26 | INTEGER {off(1), on(2), unknown(3)} | read-write | current |
| selectedOutputPowerType OBJECT-TYPE Selected output power type | 1.3.6.1.4.1.193.223.2.7.1.1.27 | INTEGER {standard(1), high(2), unknown(3)} | read-write | current |
| availableOutputPowerType OBJECT-TYPE Available output power type | 1.3.6.1.4.1.193.223.2.7.1.1.28 | INTEGER {standard(1), high(2), unknown(3)} | read-write | current |
| selectedMinOutputPower OBJECT-TYPE Selected min output power. Selected min & max output power should be set to the same value for RTPC mode, otherwise the hop operates in ATPC mode. | 1.3.6.1.4.1.193.223.2.7.1.1.29 | Integer32 | read-write | current |
| selectedMaxOutputPower OBJECT-TYPE Selected max output power. Selected min & max output power should be set to the same value for RTPC mode, otherwise the hop operates in ATPC mode. | 1.3.6.1.4.1.193.223.2.7.1.1.30 | Integer32 | read-write | current |
| availableMinOutputPower OBJECT-TYPE The minimum output power supported (dBm). The system shows a value if the equipment is available and a frame id has been selected. | 1.3.6.1.4.1.193.223.2.7.1.1.31 | Integer32 | read-only | current |
| availableMaxOutputPower OBJECT-TYPE The maximum output power supported (dBm). The system shows a value if the equipment is available and a frame id has been selected. | 1.3.6.1.4.1.193.223.2.7.1.1.32 | Integer32 | read-only | current |
| referenceSec OBJECT-TYPE Each modulation is compliant to a Reference Spectrum Efficiency Class (RSEC). When running Adaptive Coding/Modulation, one SEC has to be selected for all the coding/modulations between selectedMinACM and selectedMaxACM. This parameter is called Reference SEC. This setting will affect availableMaxOutputPower, in order to fulfill spectrum requirements. Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination. | 1.3.6.1.4.1.193.223.2.7.1.1.33 | INTEGER {noAvailable(1), sec2(2), sec4L(4), sec4H(5), sec5B(7), sec6B(9), sec5LB(10), sec5HB(11), sec6LB(12), sec6HB(13), sec7B(14), unknown(15)} | read-write | current |
| targetInputPowerFarEnd OBJECT-TYPE The wanted input power at far end (dBm), when running ATPC | 1.3.6.1.4.1.193.223.2.7.1.1.34 | Integer32 | read-write | current |
| berAlarmThreshold OBJECT-TYPE Threshold for the BER alarm | 1.3.6.1.4.1.193.223.2.7.1.1.35 | INTEGER {tenExpMinus6(1), tenExpMinus3(2)} | read-write | current |
| inputPowerAlarmThreshold OBJECT-TYPE Threshold for the input power alarm | 1.3.6.1.4.1.193.223.2.7.1.1.36 | Integer32 | read-write | current |
| plannedAlignmentInputPower OBJECT-TYPE The planned received input power (dBm) dependent upon selected minimum ACM and corresponding output power. Used when doing alignment | 1.3.6.1.4.1.193.223.2.7.1.1.37 | Integer32 | read-write | current |
| atpcFallback OBJECT-TYPE Enable or disable the output power fall back function | 1.3.6.1.4.1.193.223.2.7.1.1.38 | EnableStatusTC | read-write | current |
| atpcFallbackTimer OBJECT-TYPE Specifies the timer for output power fall back (# of seconds) | 1.3.6.1.4.1.193.223.2.7.1.1.39 | Integer32 | read-write | current |
| atpcFallbackOutputPower OBJECT-TYPE The ATPC fallback output power | 1.3.6.1.4.1.193.223.2.7.1.1.40 | Integer32 | read-write | current |
| xpicStatus OBJECT-TYPE Status of the XPIC function. | 1.3.6.1.4.1.193.223.2.7.1.1.41 | XpicMimoTC | read-only | current |
| mimoStatus OBJECT-TYPE Status of the MIMO function. | 1.3.6.1.4.1.193.223.2.7.1.1.42 | XpicMimoTC | read-only | current |
| actualSnir OBJECT-TYPE Actual signal to noise plus interference ratio (dB). | 1.3.6.1.4.1.193.223.2.7.1.1.43 | OCTET STRING | read-only | current |
| actualXpi OBJECT-TYPE The carrier to cross-polar interference level (dBc). | 1.3.6.1.4.1.193.223.2.7.1.1.44 | OCTET STRING | read-only | current |
| actualSi OBJECT-TYPE Spatial interference between the CTs when MIMO is configured. | 1.3.6.1.4.1.193.223.2.7.1.1.45 | OCTET STRING | read-only | current |
| actualTxCapacity OBJECT-TYPE Actual capacity supported by the carrier termination. | 1.3.6.1.4.1.193.223.2.7.1.1.46 | Integer32 | read-only | current |
| licensedCapacity OBJECT-TYPE Wanted or installed license for the capacity allowed for the carrier termination. | 1.3.6.1.4.1.193.223.2.7.1.1.47 | Integer32 | read-only | current |
| availableMinCapacity OBJECT-TYPE Minimum capacity possible to use. Given by the selected frame-id (kbit/s) | 1.3.6.1.4.1.193.223.2.7.1.1.48 | Integer32 | read-only | current |
| availableMaxCapacity OBJECT-TYPE Maximum capacity possible to use. Given by the selected frame-id (kbit/s) | 1.3.6.1.4.1.193.223.2.7.1.1.49 | Integer32 | read-only | current |
| selectedMinCapacity OBJECT-TYPE Selected minimum capacity, derived from selected minimum ACM (kbit/s) | 1.3.6.1.4.1.193.223.2.7.1.1.50 | Integer32 | read-only | current |
| selectedMaxCapacity OBJECT-TYPE Selected maximum capacity, derived from selected maximum ACM (kbit/s) | 1.3.6.1.4.1.193.223.2.7.1.1.51 | Integer32 | read-only | current |
| wantedLicensedCapacity OBJECT-TYPE Wanted licensed capacity and creation of LRF for the carrier termination (kbit/s) | 1.3.6.1.4.1.193.223.2.7.1.1.52 | Integer32 | read-write | current |
| availableMinAcm OBJECT-TYPE Minimum ACM possible to use, given by the selected frame id. | 1.3.6.1.4.1.193.223.2.7.1.1.53 | AcmTC | read-only | current |
| availableMaxAcm OBJECT-TYPE Maximum ACM possible to use, given by the selected frame id | 1.3.6.1.4.1.193.223.2.7.1.1.54 | AcmTC | read-only | current |
| selectedMinAcm OBJECT-TYPE Selected minimum coding/modulation. If selectedMinACM = selectedMaxACM, then the modulation is fixed | 1.3.6.1.4.1.193.223.2.7.1.1.55 | AcmTC | read-write | current |
| selectedMaxAcm OBJECT-TYPE Selected maximum coding/modulation. If selectedMinACM = selectedMaxACM, then the modulation is fixed | 1.3.6.1.4.1.193.223.2.7.1.1.56 | AcmTC | read-write | current |
| actualRxAcmTC OBJECT-TYPE Actual rx modulation and coding | 1.3.6.1.4.1.193.223.2.7.1.1.57 | AcmTC | read-only | current |
| actualTxAcmTC OBJECT-TYPE Actual tx modulation and coding | 1.3.6.1.4.1.193.223.2.7.1.1.58 | AcmTC | read-only | current |
| alignmentMode OBJECT-TYPE Enable or disable the alignment mode | 1.3.6.1.4.1.193.223.2.7.1.1.59 | EnableStatusTC | read-write | current |
| rfLoop OBJECT-TYPE Enable or disable the rf loop | 1.3.6.1.4.1.193.223.2.7.1.1.60 | EnableStatusTC | read-write | current |
| ptRadioLinkConformance OBJECT-IDENTITY | 1.3.6.1.4.1.193.223.2.7.2 | |||
| ptRadioLinkCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.193.223.2.7.2.1 | |||
| ptRadioLinkGroups OBJECT-IDENTITY | 1.3.6.1.4.1.193.223.2.7.2.2 | |||
| rltTable OBJECT-TYPE A table of RLT Table entries. | 1.3.6.1.4.1.193.223.2.7.3 | not-accessible | current | |
| rltEntry OBJECT-TYPE An entry of RLT application. | 1.3.6.1.4.1.193.223.2.7.3.1 | not-accessible | current | |
| rltDistinguishedName OBJECT-TYPE Unique id/name of the radio link termination, according to FDN (rack/slot/port/class) | 1.3.6.1.4.1.193.223.2.7.3.1.1 | OCTET STRING | read-only | current |
| neIpAddress OBJECT-TYPE NE IP address | 1.3.6.1.4.1.193.223.2.7.3.1.2 | IpAddress | read-only | current |
| neIpv6Address OBJECT-TYPE NE IP V6 address | 1.3.6.1.4.1.193.223.2.7.3.1.3 | InetAddressIPv6 | read-only | current |
| neName OBJECT-TYPE NE Name | 1.3.6.1.4.1.193.223.2.7.3.1.4 | OCTET STRING | read-only | current |
| neType OBJECT-TYPE NE Type | 1.3.6.1.4.1.193.223.2.7.3.1.5 | INTEGER {unknown(1), mle(2), xfMle(3), tn(4), cn(5), pt(6)} | read-only | current |
| id OBJECT-TYPE User defined id of the radio link terminal | 1.3.6.1.4.1.193.223.2.7.3.1.6 | OCTET STRING | read-write | current |
| rltStatus OBJECT-TYPE The status of the radio link terminal | 1.3.6.1.4.1.193.223.2.7.3.1.7 | INTEGER {down(1), up(2), na(3), unknown(4), degraded(5)} | read-only | current |
| mode OBJECT-TYPE The status of the radio link terminal | 1.3.6.1.4.1.193.223.2.7.3.1.8 | INTEGER {mode1plus0(1), mode1plus1CSB(2), mode1plus1RLP(3), mode2plus0RLB(4), mode2plus1CSB(5), mode2plus1RLP(6), mode2plus2CSB(7), mode2plus2RLP(8), mode3plus0RLB(9), mode4plus0RLB(10), notAvailable11(11), notAvailable12(12), notAvailable13(13), notAvailable14(14), mode3plus1RLP(15), mode3plus2RLP(16), mode3plus3RLP(17), mode4plus1RLP(18), mode4plus2RLP(19), mode4plus3RLP(20), mode4plus4RLP(21), notAvailable22(22), notAvailable23(23), notAvailable24(24), notAvailable25(25), notAvailable26(26), notAvailable27(27), mode3plus1CSB(28), mode3plus2CSB(29), mode3plus3CSB(30), mode4plus1CSB(31), mode4plus2CSB(32), mode4plus3CSB(33), mode4plus4CSB(34), unknown(35)} | read-write | current |
| actualTxTotalCapacity OBJECT-TYPE Actual aggregated total (packet + TDM) transmitter capacity for the radio link termination. Limited by licenses & configuration (=nearEndLimitedCapacity) and depending on actual modulation/coding used at the moment. | 1.3.6.1.4.1.193.223.2.7.3.1.9 | Integer32 | read-only | current |
| limitedTotalCapacity OBJECT-TYPE Maximum total capacity allowed by the current configuration and installed licenses. Aggregated from the constituent carrier termination values. | 1.3.6.1.4.1.193.223.2.7.3.1.10 | Integer32 | read-only | current |
| protectionStatus OBJECT-TYPE Status of a protected node. | 1.3.6.1.4.1.193.223.2.7.3.1.11 | INTEGER {unprotected(1), protected(2), unableToProtect(3), unknown(4)} | read-only | current |
| revertiveWaitToRestore OBJECT-TYPE The time, in number of seconds, to wait before switching back to the preferred Tx. | 1.3.6.1.4.1.193.223.2.7.3.1.12 | Integer32 | read-write | current |
| revertivePreferredTx OBJECT-TYPE The preferred carrier termination transmitter. | 1.3.6.1.4.1.193.223.2.7.3.1.13 | INTEGER {ct11(1), ct12(2), ct21(3), ct22(4), notApplicable(5), unknown(6)} | read-write | current |
| protectionSwitchMode OBJECT-TYPE .The mode in which the switching mechanism is configured | 1.3.6.1.4.1.193.223.2.7.3.1.14 | INTEGER {auto(1), manual(2), autoAndRevertive(3), unknown(4), notApplicable(5)} | read-write | current |
| fadeNotificationTimer OBJECT-TYPE Notification is sent if fading is longer than this timer, applicable for protection. | 1.3.6.1.4.1.193.223.2.7.3.1.15 | Integer32 | read-write | current |
| expectedFarEndId OBJECT-TYPE Expected id of far-end terminal | 1.3.6.1.4.1.193.223.2.7.3.1.16 | OCTET STRING | read-write | current |
| farEndIdCheck OBJECT-TYPE Enabling of far end id check. | 1.3.6.1.4.1.193.223.2.7.3.1.17 | INTEGER {enabled(1), disabled(2), unknown(3)} | read-write | current |
| cpriMode OBJECT-TYPE Set the mode of the CPRI front-haul product. | 1.3.6.1.4.1.193.223.2.7.3.1.18 | INTEGER {master(1), slave(2), notApplicable(3), unknown(4)} | read-write | current |
| cpriStatus OBJECT-TYPE The status of the CPRI front-haul product. | 1.3.6.1.4.1.193.223.2.7.3.1.19 | INTEGER {idle(1), waitingOnRtcSync(2), waitingOnCpri(3), waitingOnRxRequest(4), waitingOnTxRequest(5), inSync(6), unknown(7)} | read-only | current |
| manualSwitch OBJECT-TYPE Manual switch of protected carrier termination transmitter. | 1.3.6.1.4.1.193.223.2.7.3.1.20 | INTEGER {ct11(1), ct12(2), ct21(3), ct22(4), notApplicable(5), unknown(6)} | read-write | current |
| mlhcOperStatus OBJECT-TYPE Operative status of multi layer header compression. | 1.3.6.1.4.1.193.223.2.7.3.1.21 | INTEGER {up(1), down(2), unknown(3)} | read-only | current |
| mlhcAdminStatus OBJECT-TYPE Administrative status of multi layer header compression. | 1.3.6.1.4.1.193.223.2.7.3.1.22 | INTEGER {off(1), on(2), unknown(3)} | read-write | current |
| mlhcMplsConfig OBJECT-TYPE MLHC/MPLS configuration. | 1.3.6.1.4.1.193.223.2.7.3.1.23 | INTEGER {controlWord(1), l2(2), l3(3), mplsOnly(4), unknown(5)} | read-write | current |
| plcOperStatus OBJECT-TYPE Operative status of payload compression. | 1.3.6.1.4.1.193.223.2.7.3.1.24 | INTEGER {up(1), down(2), unknown(3)} | read-only | current |
| plcAdminStatus OBJECT-TYPE Administrative status of payload compression. | 1.3.6.1.4.1.193.223.2.7.3.1.25 | INTEGER {off(1), on(2), unknown(3)} | read-write | current |
| ctPerformance OBJECT-IDENTITY | 1.3.6.1.4.1.193.223.2.7.4 | |||
| ctG826ContinuousTable OBJECT-TYPE A table of CT G826 Performance Continuous counters entries. The counters are reset by ctG826Reset | 1.3.6.1.4.1.193.223.2.7.4.1 | not-accessible | current | |
| ctG826ContinuousEntry OBJECT-TYPE An entry of CT G826 Performance Continuous counters. | 1.3.6.1.4.1.193.223.2.7.4.1.1 | not-accessible | current | |
| ctG826TimeElapsed OBJECT-TYPE Time elapsed in seconds since last PMReset | 1.3.6.1.4.1.193.223.2.7.4.1.1.1 | Counter32 | read-only | current |
| ctBBE OBJECT-TYPE Background Block Errors | 1.3.6.1.4.1.193.223.2.7.4.1.1.2 | Counter32 | read-only | current |
| ctBBER OBJECT-TYPE Background Block Errors Ratio | 1.3.6.1.4.1.193.223.2.7.4.1.1.3 | OCTET STRING | read-only | current |
| ctES OBJECT-TYPE Error seconds | 1.3.6.1.4.1.193.223.2.7.4.1.1.4 | Counter32 | read-only | current |
| ctESR OBJECT-TYPE Error seconds Ratio | 1.3.6.1.4.1.193.223.2.7.4.1.1.5 | OCTET STRING | read-only | current |
| ctSES OBJECT-TYPE Severely error seconds | 1.3.6.1.4.1.193.223.2.7.4.1.1.6 | Counter32 | read-only | current |
| ctSESR OBJECT-TYPE Severely error seconds Ratio | 1.3.6.1.4.1.193.223.2.7.4.1.1.7 | OCTET STRING | read-only | current |
| ctBB OBJECT-TYPE Background blocks | 1.3.6.1.4.1.193.223.2.7.4.1.1.8 | OCTET STRING | read-only | current |
| ctUAS OBJECT-TYPE Unavailable seconds | 1.3.6.1.4.1.193.223.2.7.4.1.1.9 | Counter32 | read-only | current |
| ctG826Reset OBJECT-TYPE Reset the continuous PM counters | 1.3.6.1.4.1.193.223.2.7.4.1.1.10 | INTEGER {other(1), noReset(2), reset(3)} | read-write | current |
| ctG826Current15mTable OBJECT-TYPE A table of CT Performance G826 15 m current counters Table entries. | 1.3.6.1.4.1.193.223.2.7.4.2 | not-accessible | current | |
| ctG826Current15mEntry OBJECT-TYPE An entry of CT Performance G826 15 m current Table counters. | 1.3.6.1.4.1.193.223.2.7.4.2.1 | not-accessible | current | |
| ctG826Current15mTimeElapsed OBJECT-TYPE Time elapsed in seconds since last PMReset | 1.3.6.1.4.1.193.223.2.7.4.2.1.1 | Counter32 | read-only | current |
| ctCurrent15mBBE OBJECT-TYPE Background Block Errors | 1.3.6.1.4.1.193.223.2.7.4.2.1.2 | Counter32 | read-only | current |
| ctCurrent15mBBER OBJECT-TYPE Background Block Errors Ratio | 1.3.6.1.4.1.193.223.2.7.4.2.1.3 | OCTET STRING | read-only | current |
| ctCurrent15mES OBJECT-TYPE Error seconds | 1.3.6.1.4.1.193.223.2.7.4.2.1.4 | Counter32 | read-only | current |
| ctCurrent15mESR OBJECT-TYPE Error seconds Ratio | 1.3.6.1.4.1.193.223.2.7.4.2.1.5 | OCTET STRING | read-only | current |
| ctCurrent15mSES OBJECT-TYPE Severely error seconds | 1.3.6.1.4.1.193.223.2.7.4.2.1.6 | Counter32 | read-only | current |
| ctCurrent15mSESR OBJECT-TYPE Severely error seconds Ratio | 1.3.6.1.4.1.193.223.2.7.4.2.1.7 | OCTET STRING | read-only | current |
| ctCurrent15mBB OBJECT-TYPE Background blocks | 1.3.6.1.4.1.193.223.2.7.4.2.1.8 | Counter32 | read-only | current |
| ctCurrent15mUAS OBJECT-TYPE Unavailable seconds | 1.3.6.1.4.1.193.223.2.7.4.2.1.9 | Counter32 | read-only | current |
| ctG826Current24hTable OBJECT-TYPE A table of CT Performance G826 Current 24h counters entries. | 1.3.6.1.4.1.193.223.2.7.4.3 | not-accessible | current | |
| ctG826Current24hEntry OBJECT-TYPE An entry of CT Performance G826 Current 24 h counters. | 1.3.6.1.4.1.193.223.2.7.4.3.1 | not-accessible | current | |
| ctG826Current24hTimeElapsed OBJECT-TYPE Time elapsed in seconds since last PMReset | 1.3.6.1.4.1.193.223.2.7.4.3.1.1 | Counter32 | read-only | current |
| ctCurrent24hBBE OBJECT-TYPE Background Block Errors | 1.3.6.1.4.1.193.223.2.7.4.3.1.2 | Counter32 | read-only | current |
| ctCurrent24hBBER OBJECT-TYPE Background Block Errors Ratio | 1.3.6.1.4.1.193.223.2.7.4.3.1.3 | OCTET STRING | read-only | current |
| ctCurrent24hES OBJECT-TYPE Error seconds | 1.3.6.1.4.1.193.223.2.7.4.3.1.4 | Counter32 | read-only | current |
| ctCurrent24hESR OBJECT-TYPE Error seconds Ratio | 1.3.6.1.4.1.193.223.2.7.4.3.1.5 | OCTET STRING | read-only | current |
| ctCurrent24hSES OBJECT-TYPE Severely error seconds | 1.3.6.1.4.1.193.223.2.7.4.3.1.6 | Counter32 | read-only | current |
| ctCurrent24hSESR OBJECT-TYPE Severely error seconds Ratio | 1.3.6.1.4.1.193.223.2.7.4.3.1.7 | OCTET STRING | read-only | current |
| ctCurrent24hBB OBJECT-TYPE Background blocks | 1.3.6.1.4.1.193.223.2.7.4.3.1.8 | Counter32 | read-only | current |
| ctCurrent24hUAS OBJECT-TYPE Unavailable seconds | 1.3.6.1.4.1.193.223.2.7.4.3.1.9 | Counter32 | read-only | current |
Conformance
| Name | OID | Status |
|---|---|---|
| ptRadioLinkFullCompliance MODULE-COMPLIANCE The compliance statement for SNMP entities which implement everything. | 1.3.6.1.4.1.193.223.2.7.2.1.1 | current |
| ptRadioLinkCompleteGroup OBJECT-GROUP A collection of all current objects in this MIB module. | 1.3.6.1.4.1.193.223.2.7.2.2.1 | current |