PM8ECCMIB
- Registered at
- 1.3.6.1.4.1.3833
- Namespace
- schneider
- Source file
PM8ECCMIB- Digest
sha256:e381414a375eb840a498a70ffb8ce5774a4edaae364dbf2afebc0d673a67ae06
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
PM8ECCMIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| AlarmLabel type | ||||
| AlarmType type | ||||
| IOPointLabel type | ||||
| IOPointType type |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| schneiderElectric OBJECT-IDENTITY | 1.3.6.1.4.1.3833 | |||
| transparentFactoryEthernet OBJECT-IDENTITY | 1.3.6.1.4.1.3833.1 | |||
| equipmentProfile OBJECT-IDENTITY | 1.3.6.1.4.1.3833.1.7 | |||
| tfProducts OBJECT-IDENTITY | 1.3.6.1.4.1.3833.1.7.255 | |||
| ecc OBJECT-IDENTITY | 1.3.6.1.4.1.3833.1.7.255.15 | |||
| pm8ecc OBJECT-IDENTITY | 1.3.6.1.4.1.3833.1.7.255.15.1 | |||
| metering OBJECT-IDENTITY | 1.3.6.1.4.1.3833.1.7.255.15.1.1 | |||
| systemWiringTypeTable OBJECT-TYPE The wiring system type of the host meter. | 1.3.6.1.4.1.3833.1.7.255.15.1.1.1 | not-accessible | mandatory | |
| systemWiringTypeEntry OBJECT-TYPE Host Meter System Wiring Type | 1.3.6.1.4.1.3833.1.7.255.15.1.1.1.1 | not-accessible | mandatory | |
| swtIndex OBJECT-TYPE System Wiring Type Table Index | 1.3.6.1.4.1.3833.1.7.255.15.1.1.1.1.1 | INTEGER (1..255) | read-only | mandatory |
| swtWiringType OBJECT-TYPE Single Phase Line to Neutral 2 Wire 1CT 1PT is '10' Single Phase Line to Line 2 Wire 1CT 1PT is '11' Single Phase 3-Wire 3 wire 2CT 2PT is '12' Three Phase 3 Wire 2CT 2PT is '30' Three Phase 3 Wire 3CT 2PT is '31' Three Phase 3 Wire 1CT 2PT is '32' Three Phase 4 Wire 3CT 3PT is '40' Three Phase 4 Wire 3CT 2PT is '42' Three Phase 4 Wire 1CT 3PT is '44' | 1.3.6.1.4.1.3833.1.7.255.15.1.1.1.1.2 | INTEGER (10 | 11 | 12 | 30 | 31 | 32 | 40 | 42 | 44) | read-only | mandatory |
| loadCurrentTable OBJECT-TYPE Host Meter Load Current Table | 1.3.6.1.4.1.3833.1.7.255.15.1.1.2 | not-accessible | mandatory | |
| loadCurrentEntry OBJECT-TYPE Host Meter Load Current Table | 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1 | not-accessible | mandatory | |
| lcIndex OBJECT-TYPE Load Current Table Index | 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1.1 | INTEGER (1..255) | read-only | mandatory |
| lcIa OBJECT-TYPE Host Meter Load Current Phase A Units = A (Amps) | 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1.2 | OCTET STRING | read-only | mandatory |
| lcIb OBJECT-TYPE Host Meter Load Current Phase B Units = A (Amps) | 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1.3 | OCTET STRING | read-only | mandatory |
| lcIc OBJECT-TYPE Host Meter Load Current Phase C Units = A (Amps) | 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1.4 | OCTET STRING | read-only | mandatory |
| lcIAvg OBJECT-TYPE Host Meter Load Current 3 Phase Average Units = A (Amps) | 1.3.6.1.4.1.3833.1.7.255.15.1.1.2.1.5 | OCTET STRING | read-only | mandatory |
| powerTable OBJECT-TYPE Host Meter Power Table | 1.3.6.1.4.1.3833.1.7.255.15.1.1.3 | not-accessible | mandatory | |
| powerEntry OBJECT-TYPE Host Meter Power Table | 1.3.6.1.4.1.3833.1.7.255.15.1.1.3.1 | not-accessible | mandatory | |
| pIndex OBJECT-TYPE Power Table Index | 1.3.6.1.4.1.3833.1.7.255.15.1.1.3.1.1 | INTEGER (1..255) | read-only | mandatory |
| pReal OBJECT-TYPE Host Meter Real Power Units = kW | 1.3.6.1.4.1.3833.1.7.255.15.1.1.3.1.2 | OCTET STRING | read-only | mandatory |
| pReactive OBJECT-TYPE Host Meter Reactive Power Units = kVAR | 1.3.6.1.4.1.3833.1.7.255.15.1.1.3.1.3 | OCTET STRING | read-only | mandatory |
| pApparent OBJECT-TYPE Host Meter Apparent Power Units = kVA | 1.3.6.1.4.1.3833.1.7.255.15.1.1.3.1.4 | OCTET STRING | read-only | mandatory |
| powerFactorTable OBJECT-TYPE Host Meter Power Factor Table | 1.3.6.1.4.1.3833.1.7.255.15.1.1.4 | not-accessible | mandatory | |
| powerFactorEntry OBJECT-TYPE Host Meter Power Factor Table | 1.3.6.1.4.1.3833.1.7.255.15.1.1.4.1 | not-accessible | mandatory | |
| pfIndex OBJECT-TYPE Power Factor Table Index | 1.3.6.1.4.1.3833.1.7.255.15.1.1.4.1.1 | INTEGER (1..255) | read-only | mandatory |
| pfPowerFactorTotal OBJECT-TYPE Host Meter 3 Phase Total Power Factor | 1.3.6.1.4.1.3833.1.7.255.15.1.1.4.1.2 | OCTET STRING | read-only | mandatory |
| pfPowerFactorDescription OBJECT-TYPE Describes the current power factor Lead/Lag for IEEE mode Cap/Ind for IEC mode | 1.3.6.1.4.1.3833.1.7.255.15.1.1.4.1.3 | OCTET STRING | read-only | mandatory |
| voltageTable OBJECT-TYPE Host Meter Voltage Table | 1.3.6.1.4.1.3833.1.7.255.15.1.1.5 | not-accessible | mandatory | |
| voltageEntry OBJECT-TYPE Host Meter Voltage Table | 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1 | not-accessible | mandatory | |
| vIndex OBJECT-TYPE Voltage Table Index | 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.1 | INTEGER (1..255) | read-only | mandatory |
| vVab OBJECT-TYPE Host Meter Voltage Line A to Line B Units = V (Volts) | 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.2 | OCTET STRING | read-only | mandatory |
| vVbc OBJECT-TYPE Host Meter Voltage Line B to Line C Units = V (Volts) | 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.3 | OCTET STRING | read-only | mandatory |
| vVca OBJECT-TYPE Host Meter Voltage Line C to Line A Units = V (Volts) | 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.4 | OCTET STRING | read-only | mandatory |
| vVllAvg OBJECT-TYPE Host Meter Voltage Line to Line Average Voltage Units = V (Volts) | 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.5 | OCTET STRING | read-only | mandatory |
| vVan OBJECT-TYPE Host Meter Voltage Line A to Neutral Units = V (Volts) | 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.6 | OCTET STRING | read-only | mandatory |
| vVbn OBJECT-TYPE Host Meter Voltage Line B to Neutral Units = V (Volts) | 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.7 | OCTET STRING | read-only | mandatory |
| vVcn OBJECT-TYPE Host Meter Voltage Line C to Neutral Units = V (Volts) | 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.8 | OCTET STRING | read-only | mandatory |
| vVlnAvg OBJECT-TYPE Host Meter Voltage Line to Neutral 3 Phase Average Units = V (Volts) | 1.3.6.1.4.1.3833.1.7.255.15.1.1.5.1.9 | OCTET STRING | read-only | mandatory |
| frequencyTable OBJECT-TYPE Host Meter Frequency Table | 1.3.6.1.4.1.3833.1.7.255.15.1.1.6 | not-accessible | mandatory | |
| frequencyEntry OBJECT-TYPE Host Meter Frequency Table | 1.3.6.1.4.1.3833.1.7.255.15.1.1.6.1 | not-accessible | mandatory | |
| fIndex OBJECT-TYPE Frequency Table Index | 1.3.6.1.4.1.3833.1.7.255.15.1.1.6.1.1 | INTEGER (1..255) | read-only | mandatory |
| fFrequency OBJECT-TYPE Host Meter Frequency Units = Hz | 1.3.6.1.4.1.3833.1.7.255.15.1.1.6.1.2 | OCTET STRING | read-only | mandatory |
| currentDemandTable OBJECT-TYPE Host Meter Current Demand Table | 1.3.6.1.4.1.3833.1.7.255.15.1.1.7 | not-accessible | mandatory | |
| currentDemandEntry OBJECT-TYPE Host Meter Current Demand Table | 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1 | not-accessible | mandatory | |
| cdIndex OBJECT-TYPE Demand Current Table Index | 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.1 | INTEGER (1..255) | read-only | mandatory |
| cdPhase OBJECT-TYPE Host Meter Current Demand Phase Name | 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.2 | OCTET STRING (SIZE(2)) | read-only | mandatory |
| cdPresentCurrentDemand OBJECT-TYPE Host Meter Present Demand Current Units = A (Amps) | 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.3 | OCTET STRING | read-only | mandatory |
| cdPeakCurrentDemand OBJECT-TYPE Host Meter Peak Current Demand Units = A (Amps) | 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.4 | OCTET STRING | read-only | mandatory |
| cdLastCurrentDemand OBJECT-TYPE Host Meter Current Demand Last Interval Units = A (Amps) | 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.5 | OCTET STRING | read-only | mandatory |
| cdPeakDateTime OBJECT-TYPE Host Meter Peak Current Demand Date and Time | 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.6 | OCTET STRING | read-only | mandatory |
| cdResetDateTime OBJECT-TYPE Host Meter Date and Time of Demand Current Reset | 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.7 | OCTET STRING | read-only | mandatory |
| cdPhaseEnum OBJECT-TYPE Host Meter Current Demand Phase | 1.3.6.1.4.1.3833.1.7.255.15.1.1.7.1.8 | INTEGER {currentPhaseA(1), currentPhaseB(2), currentPhaseC(3)} | read-only | mandatory |
| powerDemandTable OBJECT-TYPE Host Meter Power Demand | 1.3.6.1.4.1.3833.1.7.255.15.1.1.8 | not-accessible | mandatory | |
| powerDemandEntry OBJECT-TYPE Host Meter Power Demand Table | 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1 | not-accessible | mandatory | |
| pdIndex OBJECT-TYPE Power Demand Table Index | 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.1 | INTEGER (1..255) | read-only | mandatory |
| pdComponent OBJECT-TYPE Host Meter Power Demand Component Units: Real = kW Reacitve = kVAR Apparent = kVA | 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.2 | OCTET STRING (SIZE(4..8)) | read-only | mandatory |
| pdPresentPowerDemand OBJECT-TYPE Host Meter Present Demand Power | 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.3 | OCTET STRING | read-only | mandatory |
| pdPeakPowerDemand OBJECT-TYPE Host Meter Peak Power Demand | 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.4 | OCTET STRING | read-only | mandatory |
| pdLastPowerDemand OBJECT-TYPE Host Meter Power Demand Last Interval | 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.5 | OCTET STRING | read-only | mandatory |
| pdPeakDateTime OBJECT-TYPE Host Meter Peak Power Demand Date and Time | 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.6 | OCTET STRING | read-only | mandatory |
| pdResetDateTime OBJECT-TYPE Host Meter Date and Time of Power Demand Reset | 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.7 | OCTET STRING | read-only | mandatory |
| pdComponentEnum OBJECT-TYPE Host Meter Power Demand Component | 1.3.6.1.4.1.3833.1.7.255.15.1.1.8.1.8 | INTEGER {realPower(1), reactivePower(2), apparentPower(3)} | read-only | mandatory |
| energyTable OBJECT-TYPE Host Meter Energy Table | 1.3.6.1.4.1.3833.1.7.255.15.1.1.9 | not-accessible | mandatory | |
| energyEntry OBJECT-TYPE Host Meter Energy Table | 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1 | not-accessible | mandatory | |
| eIndex OBJECT-TYPE Energy Table Index | 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.1 | INTEGER (1..255) | read-only | mandatory |
| eRealEnergy OBJECT-TYPE Host Meter Real Energy Units = Wh | 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.2 | OCTET STRING | read-only | mandatory |
| eDateTimeRealEnergyReset OBJECT-TYPE Host Meter Date and Time Real Energy Accumulation was reset | 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.3 | OCTET STRING | read-only | mandatory |
| eReactiveEnergy OBJECT-TYPE Host Meter Reactive Energy Units = VARh | 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.4 | OCTET STRING | read-only | mandatory |
| eDateTimeReactiveEnergyReset OBJECT-TYPE Host Meter Date and Time Reative Energy Accumulation was reset | 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.5 | OCTET STRING | read-only | mandatory |
| eApparentEnergy OBJECT-TYPE Host Meter Apparent Energy Units = VAh | 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.6 | OCTET STRING | read-only | mandatory |
| eDateTimeApparentEnergyReset OBJECT-TYPE Host Meter Date and Time Reactive Energy Accumulation was reset | 1.3.6.1.4.1.3833.1.7.255.15.1.1.9.1.7 | OCTET STRING | read-only | mandatory |
| alarms OBJECT-IDENTITY | 1.3.6.1.4.1.3833.1.7.255.15.1.2 | |||
| alarmConfigurationTable OBJECT-TYPE Displays the current configuration of the Host Meter On-board alarms | 1.3.6.1.4.1.3833.1.7.255.15.1.2.1 | not-accessible | mandatory | |
| alarmConfigurationEntry OBJECT-TYPE Contains configuration information for the Host Meter On-board Alarms | 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1 | not-accessible | mandatory | |
| acIndex OBJECT-TYPE Alarm Configuration Table Index | 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.1 | INTEGER (1..255) | read-only | mandatory |
| acPosition OBJECT-TYPE Indicates the position of the alarm. 1 - 74 | 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.2 | INTEGER (1..74) | read-only | mandatory |
| acAlarmLabel OBJECT-TYPE The name of the alarm (user configurable) | 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.3 | AlarmLabel | read-only | mandatory |
| acEnabled OBJECT-TYPE Indicates whether the alarm is enabled or not. 0 = Disabled 255 = Enabled | 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.4 | INTEGER (0 | 255) | read-only | mandatory |
| acStatus OBJECT-TYPE Indicates whether the alarm is active. 0 = Inactive 1 = Active | 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.5 | INTEGER (0..1) | read-only | mandatory |
| acCounter OBJECT-TYPE Indicates the number of times the alarm has been activated. Note: This counter resets at 32767 | 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.6 | INTEGER (0..32767) | read-only | mandatory |
| acPriority OBJECT-TYPE The priority of the alarm. 0 = No Priority 1 = Low Priority 2 = Medium Priority 3 = High Priority | 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.7 | INTEGER (0..3) | read-only | mandatory |
| acType OBJECT-TYPE Indicates the type of the alarm. | 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.8 | AlarmType | read-only | mandatory |
| acAlarmList1 OBJECT-TYPE Used for combinatorial type alarms - The position of the first alarm that is used to evaluate the alarm state. | 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.9 | INTEGER | read-only | mandatory |
| acAlarmList2 OBJECT-TYPE Used for combinatorial type alarms - The position of the second alarm that is used to evaluate the alarm state. | 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.10 | INTEGER | read-only | mandatory |
| acAlarmList3 OBJECT-TYPE Used for combinatorial type alarms - The position of the third alarm that is used to evaluate the alarm state. | 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.11 | INTEGER | read-only | mandatory |
| acAlarmList4 OBJECT-TYPE Used for combinatorial type alarms - The position of the fourth alarm that is used to evaluate the alarm state. | 1.3.6.1.4.1.3833.1.7.255.15.1.2.1.1.12 | INTEGER | read-only | mandatory |
| alarmSummaryBitmapsTable OBJECT-TYPE Indicates the state of the Host Meter On-Board Alarms | 1.3.6.1.4.1.3833.1.7.255.15.1.2.2 | not-accessible | mandatory | |
| alarmSummaryBitmapsEntry OBJECT-TYPE Indicates the status of the Host Meter On-Board Alarms | 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1 | not-accessible | mandatory | |
| alSumIndex OBJECT-TYPE Alarm Summary Bitmap Table Index | 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.1 | INTEGER (1..255) | read-only | mandatory |
| alSumAlarms1to16 OBJECT-TYPE Indicates the status of Alarms 1 - 16 (16-bits, bit-0 = Alarm 1) | 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.2 | OCTET STRING (SIZE(16)) | read-only | mandatory |
| alSumAlarms17to32 OBJECT-TYPE Indicates the status of Alarms 17 - 32 (16-bits, bit-0 = Alarm 17) | 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.3 | OCTET STRING (SIZE(16)) | read-only | mandatory |
| alSumAlarms33to48 OBJECT-TYPE Indicates the status of Alarms 33 - 48 (16-bits, bit-0 = Alarm 33) | 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.4 | OCTET STRING (SIZE(16)) | read-only | mandatory |
| alSumAlarms49to64 OBJECT-TYPE Indicates the status of Alarms 49 - 64 (16-bits, bit-0 = Alarm 49) | 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.5 | OCTET STRING (SIZE(16)) | read-only | mandatory |
| alSumAlarms65to74 OBJECT-TYPE Indicates the status of Alarms 65 - 74 (16-bits, bit-0 = Alarm 65, bit-9 = Alarm 74) | 1.3.6.1.4.1.3833.1.7.255.15.1.2.2.1.6 | OCTET STRING (SIZE(16)) | read-only | mandatory |
| alarmCountersTable OBJECT-TYPE Host Meter On-Board Alarm Counters | 1.3.6.1.4.1.3833.1.7.255.15.1.2.3 | not-accessible | mandatory | |
| alarmCountersEntry OBJECT-TYPE Host Meter On-Board Alarm Counters | 1.3.6.1.4.1.3833.1.7.255.15.1.2.3.1 | not-accessible | mandatory | |
| alCntIndex OBJECT-TYPE Alarm Counters Table Index | 1.3.6.1.4.1.3833.1.7.255.15.1.2.3.1.1 | INTEGER (1..255) | read-only | mandatory |
| alCntAlarmPosition OBJECT-TYPE The Host Meter Alarm Position | 1.3.6.1.4.1.3833.1.7.255.15.1.2.3.1.2 | INTEGER (1..74) | read-only | mandatory |
| alCntCount OBJECT-TYPE The number of times the Host Meter On-Board alarm has transitioned from an inactive state to an active state | 1.3.6.1.4.1.3833.1.7.255.15.1.2.3.1.3 | INTEGER (0..65535) | read-only | mandatory |
| io OBJECT-IDENTITY | 1.3.6.1.4.1.3833.1.7.255.15.1.3 | |||
| ioOptionIDTable OBJECT-TYPE I/O Option Module Installed on the Host Meter | 1.3.6.1.4.1.3833.1.7.255.15.1.3.1 | not-accessible | mandatory | |
| ioOptionIDEntry OBJECT-TYPE I/O Option Card Installed On-board the Host Meter | 1.3.6.1.4.1.3833.1.7.255.15.1.3.1.1 | not-accessible | mandatory | |
| ioIDIndex OBJECT-TYPE I/O Installed Option ID Table Index | 1.3.6.1.4.1.3833.1.7.255.15.1.3.1.1.1 | INTEGER (1..255) | read-only | mandatory |
| ioIDInstalledOptionSlot1 OBJECT-TYPE 0 = Not Installed 1 = Unused 2 = IO22 3 = IO26 4 = IO 2222 | 1.3.6.1.4.1.3833.1.7.255.15.1.3.1.1.2 | INTEGER {unused(1), io-22(2), io-26(3), io-2222(4)} | read-only | mandatory |
| ioIDInstalledOptionSlot2 OBJECT-TYPE 0 = Not Installed 1 = Unused 2 = IO22 3 = IO26 4 = IO 2222 | 1.3.6.1.4.1.3833.1.7.255.15.1.3.1.1.3 | INTEGER {unused(1), io-22(2), io-26(3), io-2222(4)} | read-only | mandatory |
| ioConfigurationTable OBJECT-TYPE Displays the current I/O configuration for each I/O point | 1.3.6.1.4.1.3833.1.7.255.15.1.3.2 | not-accessible | mandatory | |
| ioConfigurationEntry OBJECT-TYPE Contains configuration information for the Host Meter On-board I/O | 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1 | not-accessible | mandatory | |
| iocIndex OBJECT-TYPE I/O Configuration Table Index | 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.1 | INTEGER (1..255) | read-only | mandatory |
| iocPointNumber OBJECT-TYPE The point number for this I/O Point | 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.2 | INTEGER (1..18) | read-only | mandatory |
| iocLabel OBJECT-TYPE The name of the I/O Point (user configurable) | 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.3 | IOPointLabel | read-only | mandatory |
| iocStateOrValue OBJECT-TYPE Displays the current value for the I/O Point Digial I/O: 1 = Active or 0 = Inactive Analog I/O: Scaled input/output value | 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.4 | OCTET STRING | read-only | mandatory |
| iocPointType OBJECT-TYPE The type of I/O at this point | 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.5 | IOPointType | read-only | mandatory |
| iocMode OBJECT-TYPE For Digital Inputs and Outputs this object is always 0 indicating “Discrete”. For Analog Inputs and Outputs this object indicates the range of analog I/O values (used without units) 0 = 0 – 1 1 = 0 – 5 2 = 0 – 10 3 = 0 – 20 4 = 1 – 5 5 = 4 – 20 6 = -5 – 5 7 = -10 – 10 8 = -100 – 100 9 = User defined (values default to 0) | 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.6 | INTEGER (0..9) | read-only | mandatory |
| iocType OBJECT-TYPE For Digital Inputs this object indicates input type 1 = Unused 2 = AC/DC For Digital Outputs this object indicates output type 1 = solid state relay 2 = electromechanical relay For Analog Inputs and Outputs this object indicates the digital resolution of the I/O hardware. 0 = 8-Bit, unipolar 1 = 10-Bit, unipolar 2 = 12-Bit, unipolar 3 = 14-Bit, unipolar 4 = 16-Bit, unipolar 5 = 16-Bit, bipolar with sign 6 = reserved 7 = reserved 8 = Resolution for IO2222 Voltage range 0 - 4000 9 = Resolution for IO2222 Current range 800 - 4000 | 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.7 | INTEGER | read-only | mandatory |
| iocCount OBJECT-TYPE Number of times digital I/O point has transitioned from OFF to ON | 1.3.6.1.4.1.3833.1.7.255.15.1.3.2.1.8 | OCTET STRING (SIZE(8)) | read-only | mandatory |
| ioStatusBitmapsTable OBJECT-TYPE Host Meter I/O Status Bitmaps | 1.3.6.1.4.1.3833.1.7.255.15.1.3.3 | not-accessible | mandatory | |
| ioStatusBitmapsEntry OBJECT-TYPE Host Meter On-Board I/O Status Bitmaps | 1.3.6.1.4.1.3833.1.7.255.15.1.3.3.1 | not-accessible | mandatory | |
| ioStatIndex OBJECT-TYPE I/O Summary Bitmaps Table Index | 1.3.6.1.4.1.3833.1.7.255.15.1.3.3.1.1 | INTEGER (1..255) | read-only | mandatory |
| ioStatSummaryBitmap OBJECT-TYPE Indicates the Status of the Host Meter I/O Points Bit-0 = I/O Point 1 Bit-1 = I/O Point 2 ... Bit-17 = I/O Point 18 | 1.3.6.1.4.1.3833.1.7.255.15.1.3.3.1.2 | OCTET STRING (SIZE(18)) | read-only | mandatory |
| meterSystem OBJECT-IDENTITY | 1.3.6.1.4.1.3833.1.7.255.15.1.4 | |||
| meterIdentificationTable OBJECT-TYPE Host Meter Identification | 1.3.6.1.4.1.3833.1.7.255.15.1.4.1 | not-accessible | mandatory | |
| meterIdentificationEntry OBJECT-TYPE Host Meter Identification | 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1 | not-accessible | mandatory | |
| midIndex OBJECT-TYPE Meter Identification Table Index | 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1.1 | INTEGER (1..255) | read-only | mandatory |
| midSerialNumber OBJECT-TYPE Host meter 32 bit Serial Number | 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1.2 | INTEGER | read-only | mandatory |
| midFirmwareVersion OBJECT-TYPE Host Meter Firmware Version | 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1.3 | OCTET STRING | read-only | mandatory |
| midModelNumber OBJECT-TYPE Host Meter Model Number | 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1.4 | OCTET STRING | read-only | mandatory |
| midDeviceName OBJECT-TYPE Host Meter Label plus Nameplate | 1.3.6.1.4.1.3833.1.7.255.15.1.4.1.1.5 | OCTET STRING | read-only | mandatory |
| trapVariables OBJECT-IDENTITY | 1.3.6.1.4.1.3833.1.7.255.15.1.5 | |||
| alarmDateAndTime OBJECT-TYPE The Date and Time of the alarm state change. | 1.3.6.1.4.1.3833.1.7.255.15.1.5.1 | OCTET STRING | read-only | mandatory |
| alarmLabel OBJECT-TYPE The Descriptive Label given to the alarm | 1.3.6.1.4.1.3833.1.7.255.15.1.5.2 | OCTET STRING | read-only | mandatory |
| alarmState OBJECT-TYPE The state of the Alarm - pickup, dropout, unary, diagnostic | 1.3.6.1.4.1.3833.1.7.255.15.1.5.3 | OCTET STRING | read-only | mandatory |
| alarmValue OBJECT-TYPE The value of the alarm when it changed state. | 1.3.6.1.4.1.3833.1.7.255.15.1.5.4 | INTEGER | read-only | mandatory |
| alarmPriority OBJECT-TYPE The priority defined for the alarm. | 1.3.6.1.4.1.3833.1.7.255.15.1.5.5 | INTEGER {highPriority(1), mediumPriority(2), lowPriority(3)} | read-only | mandatory |
| mibVersion OBJECT-TYPE This is the current version of the MIB | 1.3.6.1.4.1.3833.1.7.255.15.1.6 | OCTET STRING | read-only | mandatory |
Notifications
| Name | OID | Status |
|---|---|---|
| pm8OnBoardAlarmP1 NOTIFICATION-TYPE Indicates the Host Meter On-Board Alarm system has detected a state change of an enabled alarm with a priority of 1 | 1.3.6.1.4.1.3833.1.7.255.15.1.0.1 | |
| pm8OnBoardAlarmP2 NOTIFICATION-TYPE Indicates the Host Meter On-Board Alarm system has detected a state change of an enabled alarm with a priority of 2 | 1.3.6.1.4.1.3833.1.7.255.15.1.0.2 | |
| pm8OnBoardAlarmP3 NOTIFICATION-TYPE Indicates the Host Meter On-Board Alarm system has detected a state change of an enabled alarm with a priority of 3 | 1.3.6.1.4.1.3833.1.7.255.15.1.0.3 |