PERLE-MCR-MGT-MIB
- Registered at
- 1.3.6.1.4.1.1966
- Last updated
- 2014-09-03 00:00
- Organization
- Perle Systems Limited
- Revisions
- 2014-09-03 00:00, 2013-03-02 00:00, 2012-11-15 00:00, 2012-02-01 00:00, 2011-01-20 00:00, 2011-01-12 00:00, 2010-09-10 00:00
- Namespace
- perle
- Source file
PERLE-MCR-MGT-MIB- Digest
sha256:4a5571ab3bdf3d6b6029fc4162c82f1fffe04b9ee8978e2cd2897d8cd9a66913
Description
The private MIB module for the Perle Managed Media Converters
Contact
Postal: Perle Systems Limited 60 Renfrew Drive Markham, Ontario Canada L3R 0E1 http://www.perle.com/
Imports
| From | Symbols |
|---|---|
| SNMP-FRAMEWORK-MIB | SnmpEngineID |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Counter64, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, enterprises, iso |
| SNMPv2-TC | DateAndTime, DisplayString, MacAddress, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
PERLE-MCR-MGT-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| AlertSeverityLevel TEXTUAL-CONVENTION The alert severity level of an event. | current | |||
| ContainerStatus TEXTUAL-CONVENTION When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module. 6-Indicates that the changes in the container folder are to be discarded. | current | |||
| EnableDisableValue TEXTUAL-CONVENTION Represents an ON or OFF value. | current | |||
| GenericTableIndex TEXTUAL-CONVENTION An arbitrary value that uniquely identifies the entity. The value should be a small, positive integer. Index values for different entities are not necessarily contiguous. | current | |||
| Ipv4v6Address TEXTUAL-CONVENTION An IPv4 or IPv6 address | current | |||
| OnOffValue TEXTUAL-CONVENTION Represents an ON or OFF value. | current | |||
| SlotNumber TEXTUAL-CONVENTION Chassis slot number. Valid values are 1 to the highest slot number the chassis supports. For example a MCR-1900 chassis the valid slot numbers are 1 to 19 | current | |||
| YesNoValue TEXTUAL-CONVENTION Represents a YES or NO value. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| perle OBJECT-IDENTITY | 1.3.6.1.4.1.1966 | |||
| productId OBJECT-IDENTITY | 1.3.6.1.4.1.1966.20 | |||
| mediaConverter OBJECT-IDENTITY | 1.3.6.1.4.1.1966.20.1 | |||
| mcrMGT OBJECT-IDENTITY | 1.3.6.1.4.1.1966.20.1.1 | |||
| productMIB OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21 | |||
| mediaconverterMIB OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1 | |||
| mcrMGTMIBNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.0 | |||
| mcrMGTMIBObjects OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1 | |||
| mcrChassisGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.1 | |||
| mcrChassisTable OBJECT-TYPE Table of chassis diagnostic type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.1 | not-accessible | current | |
| mcrChassisEntry OBJECT-TYPE Entries of the table, each relating to a separate chassis. | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1 | not-accessible | current | |
| mcrChassisIndex OBJECT-TYPE This object identifies the chassis number. | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.1 | Unsigned32 | accessible-for-notify | current |
| chassisModelName OBJECT-TYPE This object identifies the name of the chassis model. For the 2-slot chassis, this is the product model. | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.2 | DisplayString | read-only | current |
| chassisModelDesc OBJECT-TYPE This object identifies a static description of the chassis. | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.3 | DisplayString | read-only | current |
| chassisSerialNumber OBJECT-TYPE This object identifies the chassis serial number. For the 2-slot chassis, this is writeable (and user-defined). For other chassis, this is read-only (and reflects the chassis' actual serial number). | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.4 | DisplayString (SIZE(0..16)) | read-write | current |
| chassisBootloaderVersion OBJECT-TYPE This object identifies the chassis bootloader version. (Not applicable to 2-slot chassis.) | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.5 | DisplayString | read-only | current |
| chassisFirmwareVersion OBJECT-TYPE This object identifies the chassis firmware version. (Not applicable to 2-slot chassis.) | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.6 | DisplayString | read-only | current |
| chassisOutStandWarnAlarms OBJECT-TYPE This object identifies the number of outstanding warnings and alarms for this chassis. If this value is not zero then user intervention is needed to resolve the outstanding warnings and alarms. (Not applicable to 2-slot chassis.) | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.7 | Unsigned32 | read-only | current |
| chassisDiagStatus OBJECT-TYPE This object identifies the chassis self-test diagnostics result. It will return zero if it passed and non-zero error code if it failed. The following are possible non-zero error codes: 1 - Firmware download required 2 - Temperature sensor not functional (Not applicable to 2-slot chassis.) | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.8 | Unsigned32 | read-only | current |
| chassisTemperature OBJECT-TYPE This object identifies the current temperature of the chassis. The temperature returned will be either Celsius or Fahrenheit based on your current regional display settings. If the temperature returned is -1 then a problem with the temperature sensor has occurred and the current temperature is unknown. (Not applicable to 2-slot chassis.) | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.9 | Integer32 | read-only | current |
| chassisCfgHighTempThreshold OBJECT-TYPE This object identifies the chassis temperature high threshold. If the chassis temperature exceeds this threshold then an alert will be generated. The value read/written will be either Celsius or Fahrenheit based on your current regional display settings. The valid range for this threshold is 0 to 70 degrees Celsius or 32 to 158 degrees Fahrenheit. (Not applicable to 2-slot chassis.) | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.10 | Integer32 | read-write | current |
| chassisReset OBJECT-TYPE This object allows the resetting of the chassis (all modules). Reading this object always returns 0. | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.11 | YesNoValue | read-write | current |
| chassisCfgMgmtSlot OBJECT-TYPE For the 2-slot chassis, this is the configured slot index of the management module. This value only needs to be changed if the management module is physically installed in slot 2, rather than slot 1. The management module should be restarted after changing this value. | 1.3.6.1.4.1.1966.21.1.1.1.1.1.1.12 | Unsigned32 (1..2) | read-write | current |
| mcrPsmuTable OBJECT-TYPE Table of PSMU (Power Supply Monitoring Unit) diagnostic type information. (Not applicable to 2-slot chassis.) | 1.3.6.1.4.1.1966.21.1.1.1.1.2 | not-accessible | current | |
| mcrPsmuEntry OBJECT-TYPE Entries of the table, each relating to a separate PSMU. | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1 | not-accessible | current | |
| mcrPsmuIndex OBJECT-TYPE This object identifies the PSMU bay as either A or B. | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.2 | INTEGER {a(1), b(2)} | accessible-for-notify | current |
| mcrPsmuModelName OBJECT-TYPE This object identifies the PSMU model. | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.3 | DisplayString | read-only | current |
| mcrPsmuModelDesc OBJECT-TYPE This object identifies a static description of the power supply model present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.4 | DisplayString | read-only | current |
| mcrPsmuPsuSerialNumber OBJECT-TYPE This object identifies the PSU serial number. | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.5 | DisplayString (SIZE(0..16)) | read-only | current |
| mcrPsmuBootloaderVersion OBJECT-TYPE This object identifies the PSMU bootloader version. | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.6 | DisplayString | read-only | current |
| mcrPsmuFirmwareVersion OBJECT-TYPE This object identifies the PSMU firmware version. | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.7 | DisplayString | read-only | current |
| mcrPsmuOutStandWarnAlarms OBJECT-TYPE This object identifies the number of outstanding warnings and alarms for this chassis. If this value is not zero then user intervention is needed to resolve the outstanding warnings and alarms | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.8 | Unsigned32 | read-only | current |
| mcrPsmuPsuStatus OBJECT-TYPE This object identifies if the PSMU power supply unit (PSU) status. | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.9 | INTEGER {notPresent(0), good(1), fail(2)} | read-only | current |
| mcrPsmuPsuVoltage OBJECT-TYPE This object identifies the current PSU voltage being supplied. | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.10 | DisplayString | read-only | current |
| mcrPsmuPsuPowerUsage OBJECT-TYPE This object identifies power currently being supplied to the chassis, in milliwatts. A value of 0 indicate that the power supply is not in use | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.11 | DisplayString | read-only | current |
| mcrPsmuFanStatus OBJECT-TYPE This object identifies the fan status. | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.12 | INTEGER {notPresent(0), good(1), fail(2)} | read-only | current |
| mcrPsmuFanSpeed OBJECT-TYPE This object identifies the speed of the fan in RPM. | 1.3.6.1.4.1.1966.21.1.1.1.1.2.1.13 | Unsigned32 | read-only | current |
| mcrChassisSlotTable OBJECT-TYPE Table of chassis slot configuration, status and diagnostic type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.3 | not-accessible | current | |
| mcrChassisSlotEntry OBJECT-TYPE Entries of the table, each relating to a separate slot in a chassis. | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1 | not-accessible | current | |
| mcrChassisSlotIndex OBJECT-TYPE This object identifies the chassis slot number. | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.2 | SlotNumber | accessible-for-notify | current |
| mcrUserDefinedModuleName OBJECT-TYPE This object identifies the user defined name of the module inserted in the slot. The default name is the model name of the media converter module | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.3 | DisplayString | read-only | current |
| mcrModuleModelName OBJECT-TYPE This object identifies the model name of the module inserted in the slot. | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.4 | DisplayString | read-only | current |
| mcrUnManagedModuleSlotName OBJECT-TYPE This object identifies the user defined name for an unmanaged module inserted in the slot. Unmanaged modules include all perle C-1000, C-100, C-1110 and c-110 type modules. | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.5 | DisplayString | read-write | current |
| mcrModuleSerialNumber OBJECT-TYPE This object identifies the serial number of the module inserted in the slot. | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.6 | DisplayString (SIZE(0..16)) | read-only | current |
| mcrModuleBootloaderVersion OBJECT-TYPE This object identifies the bootloader version of the module inserted in the slot. | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.7 | DisplayString | read-only | current |
| mcrModuleFirmwareVersion OBJECT-TYPE This object identifies the firmware version of the module inserted in the slot. | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.8 | DisplayString | read-only | current |
| mcrModuleoOutStandWarnAlarms OBJECT-TYPE This object identifies the number of outstanding warnings and alarms for this module. If this value is not zero then user intervention is needed to resolve the outstanding warnings and alarms | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.9 | Unsigned32 | read-only | current |
| mcrModuleDiagStatus OBJECT-TYPE This object identifies the module's self-test diagnostics result. It will return zero if it passed and non-zero error code if the module has failed.The following are possible non-zero error codes: 1 - Media converter module's PHY is not functional. 2 - Firmware download required | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.10 | Integer32 | read-only | current |
| mcrModuleTypeInserted OBJECT-TYPE This object identifies the module type inserted for this chassis slot. | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.11 | INTEGER {unManaged(-3), mcrMgt(-2), unknown(-1), empty(0), cm1000Fixed(1), cm100Fixed(2), cm1110RateConv(3), cm110RateConv(4), cm100mmFixed(5), cm1000mmFixed(6), cm10gFixed(7), exCM(8), cm10gt(9), cm4gpt(10)} | read-only | current |
| mcrMediaConfigBackupRestore OBJECT-TYPE This object is applicable to media converter modules only. It identifies whether the media configuration will be automatically backed up to or restored from the management card's non-volatile memory | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.12 | INTEGER {disable(0), enable(1), notApplicable(2)} | read-write | current |
| mcrMediaBackedupModuleType OBJECT-TYPE This object identifies the media converter module type of the configuration that was backed up for the slot on the management card's non-volatile memory when the mcrMediaConfigBackupRestore object was enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.13 | INTEGER {none(0), cm1000Fixed(1), cm100Fixed(2), cm1110RateConv(3), cm110RateConv(4), cm100mmFixed(5), cm1000mmFixed(6), cm10gFixed(7), exCM(8), cm10gt(9), cm4gpt(10)} | read-only | current |
| mcrChassisPwrUpSlotPwrState OBJECT-TYPE This object identifies the default power state of the slot when the chassis is initially powered up. The current power state of the slot can be manually changed by writing to mcrCurrentPowerState object or dynamically changed via slot power schedule configuration. (Not applicable to 2-slot chassis.) | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.14 | OnOffValue | read-write | current |
| mcrCurrentPowerState OBJECT-TYPE Writing this object allows the current power state of the slot to be turned on or off. This object is not writable for management modules or the 2-slot chassis. Reading this object will return the current slot power state. | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.15 | OnOffValue | read-write | current |
| mcrPowerScheduleEnable OBJECT-TYPE This object is not applicable to management modules. It identifies if power schedule is enabled for the slot. (Not applicable to 2-slot chassis.) | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.16 | INTEGER {no(0), yes(1), notApplicable(2)} | read-write | current |
| mcrModuleReset OBJECT-TYPE This object allows you to reset the module inserted in the slot. | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.17 | INTEGER {no(0), yes(1), notApplicable(2)} | read-write | current |
| mcrModuleResetToFactory OBJECT-TYPE This object allows you to reset to factory the module inserted in the slot. | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.18 | INTEGER {no(0), yes(1), notApplicable(2)} | read-write | current |
| mcrModuleModelDesc OBJECT-TYPE This object identifies a static description of the media converter module present in the slot. | 1.3.6.1.4.1.1966.21.1.1.1.1.3.1.19 | DisplayString | read-only | current |
| mcrModuleTypes OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.1.4 | |||
| cm1000Fixed OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1 | |||
| cm1000FixedTable OBJECT-TYPE Table of CM-1000 type media converter module's status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1 | not-accessible | current | |
| cm1000FixedEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-1000 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1 | not-accessible | current | |
| cm1000SlotIndex OBJECT-TYPE The Slot number the CM-1000 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.2 | SlotNumber | not-accessible | current |
| cm1000Modelname OBJECT-TYPE This object identifies the model of media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.3 | DisplayString | read-only | current |
| cm1000ModelDesc OBJECT-TYPE This object identifies a static description of the media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.4 | DisplayString | read-only | current |
| cm1000HwJmp5ConfigMode OBJECT-TYPE This object identifies the media converter module's ConfigMode, set by hardware jumper J5 on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media converter module's hardware switches or jumpers. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.5 | INTEGER {hardwareSwitches(0), auto(1)} | read-only | current |
| cm1000HwSw1FiberAutoNeg OBJECT-TYPE Media converter module's current switch setting for fiber Auto-Negotiation. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.6 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| cm1000HwSw2LinkMode OBJECT-TYPE Media converter module's current switch setting for Link Mode. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.7 | INTEGER {swDownSmartLinkPassthrough(0), swUpStandard(1)} | read-only | current |
| cm1000HwSw3FiberFaultAlert OBJECT-TYPE Media converter module's current switch setting for Fiber Fault Alert. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.8 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| cm1000HwSw4Duplex OBJECT-TYPE Media converter module's current switch setting for copper duplex. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.9 | INTEGER {swDownHalf(0), swUpAuto(1)} | read-only | current |
| cm1000HwSw5Pause OBJECT-TYPE Media converter module's current switch setting for copper pause (flow control). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.10 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| cm1000HwSw6Loopback OBJECT-TYPE Media converter module's current switch setting for fiber loopback mode. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.11 | INTEGER {swDownEnabled(0), swUpDisabled(1)} | read-only | current |
| cm1000FiberLinkStatus OBJECT-TYPE Media converter module's current fiber link status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.12 | INTEGER {down(0), up(1)} | read-only | current |
| cm1000FiberConnType OBJECT-TYPE Media converter module's fiber port connector type. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.13 | INTEGER {sc(0), lc(1), st(2), sfp(3), fc(5), mtrj(6)} | read-only | current |
| cm1000FiberAutoNegState OBJECT-TYPE Media converter module's current fiber auto-negotiation state. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.14 | INTEGER {disabled(0), complete(1), inProgress(2)} | read-only | current |
| cm1000FiberSpeed OBJECT-TYPE Media converter module's fiber port speed in megabits per second. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.15 | INTEGER {speed1000Mbps(2)} | read-only | current |
| cm1000FiberDuplex OBJECT-TYPE If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.16 | INTEGER {half(0), full(1)} | read-only | current |
| cm1000FiberPauseEnh OBJECT-TYPE If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.17 | INTEGER {disabled(0), symmetrical(1), asymmetricalTx(2), asymmetricalRx(3)} | read-only | current |
| cm1000FiberLPRFStatus OBJECT-TYPE Media converter module's fiber Link Partner Remote Fault status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.18 | INTEGER {ok(0), offline(1), linkFault(2), autoNegError(3)} | read-only | current |
| cm1000FiberReceiveStatus OBJECT-TYPE This object identifies the status of whether light is being received on the fiber port | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.19 | INTEGER {fault(0), ok(1)} | read-write | current |
| cm1000FiberLoopBack OBJECT-TYPE Media converter module's current fiber loopback mode setting. Writing to this object will change the current settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.20 | EnableDisableValue | read-write | current |
| cm1000CopperLinkStatus OBJECT-TYPE Media converter module's current copper link status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.21 | INTEGER {down(0), up(1)} | read-only | current |
| cm1000CopperConnType OBJECT-TYPE Media converter module's copper connector type. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.22 | INTEGER {rj45(0)} | read-only | current |
| cm1000CopperAutoNegState OBJECT-TYPE Media converter module's current copper auto-negotiation state. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.23 | INTEGER {disabled(0), complete(1), inProgress(2)} | read-only | current |
| cm1000CopperSpeed OBJECT-TYPE Media converter module's copper port speed in megabits per second. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.24 | INTEGER {speed1000Mbps(2)} | read-only | current |
| cm1000CopperDuplex OBJECT-TYPE If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.25 | INTEGER {half(0), full(1)} | read-only | current |
| cm1000CopperCrossOver OBJECT-TYPE If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated MDI/MDI-X setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.26 | INTEGER {mdi(0), mdix(1)} | read-only | current |
| cm1000CopperPauseEnh OBJECT-TYPE If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.27 | INTEGER {disabled(0), symmetrical(1), asymmetricalTx(2), asymmetricalRx(3)} | read-only | current |
| cm1000CopperLPRFStatus OBJECT-TYPE Media converter module's copper Link Partner Remote Fault status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.1.1.28 | INTEGER {ok(0), remoteFault(1)} | read-only | current |
| cm1000ConfigTable OBJECT-TYPE Table of CM-1000 type media converter module's configuration type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2 | not-accessible | current | |
| cm1000ConfigEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-1000 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1 | not-accessible | current | |
| cm1000ConfigSlotIndex OBJECT-TYPE The Slot number the CM-1000 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.2 | SlotNumber | not-accessible | current |
| cm1000ConfigStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.3 | ContainerStatus | read-write | current |
| cm1000ConfigModuleName OBJECT-TYPE This object identifies a user configurable name for the media converter module present in the chassis. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.4 | DisplayString (SIZE(0..63)) | read-write | current |
| cm1000ConfigLinkMode OBJECT-TYPE This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.5 | INTEGER {standard(0), smartLinkPassthrough(1)} | read-write | current |
| cm1000ConfigFiberFaultAlert OBJECT-TYPE This object identifies the Fiber Fault Alert setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.6 | EnableDisableValue | read-write | current |
| cm1000ConfigJumboPackets OBJECT-TYPE This object identifies the Jumbo Packet setting for the media converter module present in the chassis. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.7 | EnableDisableValue | read-write | current |
| cm1000ConfigFiberPortName OBJECT-TYPE This object identifies a user definable name for the fiber port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.8 | DisplayString (SIZE(0..8)) | read-write | current |
| cm1000ConfigFiberPortEnable OBJECT-TYPE This object identifies whether the fiber port is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.9 | YesNoValue | read-write | current |
| cm1000ConfigFiberAutoNeg OBJECT-TYPE This object identifies the wither fiber auto-negotiation is enabled. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.10 | EnableDisableValue | read-write | current |
| cm1000ConfigCopperPortName OBJECT-TYPE This object identifies a user definable name for the copper port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.11 | DisplayString (SIZE(0..8)) | read-write | current |
| cm1000ConfigCopperPortEnable OBJECT-TYPE This object identifies whether the fiber port is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.12 | YesNoValue | read-write | current |
| cm1000ConfigCopperDuplex OBJECT-TYPE This object identifies the duplex settings for the copper port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.13 | INTEGER {half(1), auto(2)} | read-write | current |
| cm1000ConfigCopperPauseEnh OBJECT-TYPE This object identifies the copper pause (flow control) setting that is a advertised. The settings can be disabled, advertise symmetrical, advertise asymmetrical TX or advertise symmetrical and asymmetrical RX. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.14 | INTEGER {disabled(0), symmetrical(1), asymmetricalTx(2), symmAsymRx(3)} | read-write | current |
| cm1000ConfigCopperLowPower OBJECT-TYPE This object identifies the copper low power setting for the media converter module present in the chassis. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.2.1.15 | OnOffValue | read-write | current |
| cm1000LedTable OBJECT-TYPE Table of CM-1000 type media converter module's LED status information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3 | not-accessible | current | |
| cm1000LedEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-1000 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3.1 | not-accessible | current | |
| cm1000LedSlotIndex OBJECT-TYPE The Slot number the CM-1000 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3.1.2 | SlotNumber | not-accessible | current |
| cm1000LedPWR OBJECT-TYPE This object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Fiber loopback enabled | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3.1.3 | INTEGER {off(0), onGreen(1), blinking(2)} | read-only | current |
| cm1000LedLKF OBJECT-TYPE This object identifies the status of the link copper (LKC) LED on the media converter module. Possible status values are: off(0) - No fiber link on(1) - Fiber link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3.1.4 | INTEGER {off(0), on(1)} | read-only | current |
| cm1000LedLKC OBJECT-TYPE This object identifies the status of the link copper (LKC) LED on the media converter module. Possible status values are: off(0) - No copper link on(1) - Copper link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.1.3.1.5 | INTEGER {off(0), on(1)} | read-only | current |
| cm100Fixed OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2 | |||
| cm100FixedTable OBJECT-TYPE Table of CM-100 type media converter module's configuration and status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1 | not-accessible | current | |
| cm100FixedEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-1000 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1 | not-accessible | current | |
| cm100SlotIndex OBJECT-TYPE The Slot number the CM-100 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.2 | SlotNumber | not-accessible | current |
| cm100ModelName OBJECT-TYPE This object identifies the model of media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.3 | DisplayString | read-only | current |
| cm100ModelDesc OBJECT-TYPE This object identifies a static description of the media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.4 | DisplayString | read-only | current |
| cm100HwJmp5ConfigMode OBJECT-TYPE This object identifies the media converter module's ConfigMode, set by hardware switch on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media module's hardware switches or jumpers. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.5 | INTEGER {hardwareSwitches(0), auto(1)} | read-only | current |
| cm100HwJmp6AutoMDI OBJECT-TYPE This object identifies the media converter module's hardware Auto MDIX jumper settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.6 | INTEGER {mdi(0), auto(1)} | read-only | current |
| cm100HwSw1AutoNegotiation OBJECT-TYPE Media converter module's current switch setting for fiber Auto-Negotiation. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.7 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| cm100HwSw2LinkMode OBJECT-TYPE Media converter module's current switch setting for Link Mode. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.8 | INTEGER {swDownStandardMode(0), swUpLinkPassthroughMode(1)} | read-only | current |
| cm100HwSw3FarEndFault OBJECT-TYPE Media converter module's current switch setting for Far End Fault. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.9 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| cm100HwSw5Pause OBJECT-TYPE Media converter module's current switch setting for copper pause (flow control). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.10 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| cm100HwSw6Loopback OBJECT-TYPE Media converter module's current switch setting for fiber loopback mode. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.11 | INTEGER {swDownEnabled(0), swUpDisabled(1)} | read-only | current |
| cm100FiberLinkStatus OBJECT-TYPE Media converter module's current fiber link status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.12 | INTEGER {down(0), up(1)} | read-only | current |
| cm100FiberConnType OBJECT-TYPE Media converter module's fiber port connector type. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.13 | INTEGER {sc(0), lc(1), st(2), sfp(3), fc(5), mtrj(6)} | read-only | current |
| cm100FiberSpeed OBJECT-TYPE Media converter module's fiber port speed in megabits per second. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.14 | INTEGER {speed100Mbps(1)} | read-only | current |
| cm100FiberFarEndFault OBJECT-TYPE Media converter module's current fiber Far End Fault status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.15 | INTEGER {disable(0), ok(1), receivingFEF(2), sendingFEF(3)} | read-only | current |
| cm100FiberReceiveStatus OBJECT-TYPE This object identifies the status of whether light is being received on the fiber port | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.16 | INTEGER {fault(0), ok(1)} | read-write | current |
| cm100FiberLoopBack OBJECT-TYPE This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.17 | EnableDisableValue | read-write | current |
| cm100CopperLinkStatus OBJECT-TYPE Media converter module's current copper link status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.18 | INTEGER {down(0), up(1)} | read-only | current |
| cm100CopperConnType OBJECT-TYPE Media converter module's copper connector type. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.19 | INTEGER {rj45(0)} | read-only | current |
| cm100CopperAutoNegState OBJECT-TYPE Media converter module's current copper auto-negotiation state. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.20 | INTEGER {disabled(0), complete(1), inProgress(2)} | read-only | current |
| cm100CopperSpeed OBJECT-TYPE This object identifies the copper port speed in megabits per second. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.21 | INTEGER {speed100Mbps(1)} | read-only | current |
| cm100CopperDuplex OBJECT-TYPE If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.22 | INTEGER {half(0), full(1)} | read-only | current |
| cm100CopperCrossOver OBJECT-TYPE If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated MDI/MDI-X setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.23 | INTEGER {mdi(0), mdix(1)} | read-only | current |
| cm100CopperPause OBJECT-TYPE If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated pause (flow control) setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.24 | INTEGER {disabled(0), symmetrical(1)} | read-only | current |
| cm100CopperLPRFStatus OBJECT-TYPE Media converter module's copper Link Partner Remote Fault status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.1.1.25 | INTEGER {ok(0), remoteFault(1)} | read-only | current |
| cm100ConfigTable OBJECT-TYPE Table of CM-100 type media converter module's configuration and status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2 | not-accessible | current | |
| cm100ConfigEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-1000 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1 | not-accessible | current | |
| cm100ConfigSlotIndex OBJECT-TYPE The Slot number the CM-1000 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.2 | SlotNumber | not-accessible | current |
| cm100ConfigStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.3 | ContainerStatus | read-write | current |
| cm100ConfigModuleName OBJECT-TYPE This object identifies a user configurable name for the media converter module present in the chassis. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.4 | DisplayString (SIZE(0..63)) | read-write | current |
| cm100ConfigLinkMode OBJECT-TYPE This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.5 | INTEGER {standard(0), linkPassthrough(1)} | read-write | current |
| cm100ConfigFiberFarEndFault OBJECT-TYPE This object identifies the fiber Far End Fault setting for the media module. This setting is always enabled if Link Mode is set to linkPassthrough. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.6 | EnableDisableValue | read-write | current |
| cm100ConfigFiberPortName OBJECT-TYPE This object identifies a user definable name for the fiber port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.7 | DisplayString (SIZE(0..8)) | read-write | current |
| cm100ConfigFiberPortEnable OBJECT-TYPE This object identifies whether the fiber port is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.8 | YesNoValue | read-write | current |
| cm100ConfigCopperPortName OBJECT-TYPE This object identifies a user definable name for the copper port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.9 | DisplayString (SIZE(0..8)) | read-write | current |
| cm100ConfigCopperPortEnable OBJECT-TYPE This object identifies whether the fiber port is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.10 | YesNoValue | read-write | current |
| cm100ConfigCopperAutoNegotiation OBJECT-TYPE This object identifies the whether copper auto-negotiation is enabled. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.11 | EnableDisableValue | read-write | current |
| cm100ConfigCopperCrossOver OBJECT-TYPE This object identifies the copper MDI/MDI-X setting.This object is read-only if the media converter module's ConfigMode jumper is set to | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.12 | INTEGER {auto(0), mdi(1), mdix(2)} | read-write | current |
| cm100ConfigCopperPause OBJECT-TYPE This object identifies the copper's port pause (flow control) settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.2.1.13 | INTEGER {disabled(0), symmetrical(1)} | read-write | current |
| cm100LedTable OBJECT-TYPE Table of CM-100 type media converter module's LED status information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3 | not-accessible | current | |
| cm100LedEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-100 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3.1 | not-accessible | current | |
| cm100LedSlotIndex OBJECT-TYPE The Slot number the CM-100 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3.1.2 | SlotNumber | not-accessible | current |
| cm100LedPWR OBJECT-TYPE This object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Fiber loopback enabled | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3.1.3 | INTEGER {off(0), onGreen(1), blinking(2)} | read-only | current |
| cm100LedLKF OBJECT-TYPE This object identifies the status of the link fiber (LKF) LED on the media converter module. Possible status values are: off(0) - No fiber link on(1) - Fiber link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3.1.4 | INTEGER {off(0), on(1)} | read-only | current |
| cm100LedLKC OBJECT-TYPE This object identifies the status of the link copper (LKC) LED on the media converter module. Possible status values are: off(0) - No copper link on(1) - Copper link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.2.3.1.5 | INTEGER {off(0), on(1)} | read-only | current |
| cm1110RateConv OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3 | |||
| cm1110RateConvTable OBJECT-TYPE Table of CM-1110 type media converter module's configuration and status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1 | not-accessible | current | |
| cm1110RateConvEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-1110 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1 | not-accessible | current | |
| cm1110SlotIndex OBJECT-TYPE The Slot number the CM-1110 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.2 | SlotNumber | not-accessible | current |
| cm1110ModelName OBJECT-TYPE This object identifies the model of media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.3 | DisplayString | read-only | current |
| cm1110ModelDesc OBJECT-TYPE This object identifies a static description of the media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.4 | DisplayString | read-only | current |
| cm1110HwJmp5ConfigMode OBJECT-TYPE This object identifies the media converter module's ConfigMode, set by hardware switch on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media module's hardware switches or jumpers. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.5 | INTEGER {hardwareSwitches(0), auto(1)} | read-only | current |
| cm1110HwJmp6AutoMDIX OBJECT-TYPE This object identifies the media converter module's hardware Auto MDIX jumper settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.6 | INTEGER {mdix(0), auto(1)} | read-only | current |
| cm1110HwSw1TpAutoNegotiation OBJECT-TYPE Media converter module's current switch setting for copper Auto-Negotiation. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.7 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| cm1110HwSw2LinkMode OBJECT-TYPE Media converter module's current switch setting for Link Mode. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.8 | INTEGER {swDownNormalMode(0), swUpSmartLinkPassthroughMode(1)} | read-only | current |
| cm1110HwSw3FiberFaultAlert OBJECT-TYPE Media converter module's current switch setting for Fiber Fault Alert. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.9 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| cm1110HwSw4TpDuplex OBJECT-TYPE Media converter module's current switch setting for copper duplex. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.10 | INTEGER {swDownHalf(0), swUpFull(1)} | read-only | current |
| cm1110HwSw5TpSpeed OBJECT-TYPE Media converter module's current switch setting for Link Mode. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.11 | INTEGER {swDown10Mbps(0), swUp100Mbps(1)} | read-only | current |
| cm1110HwSw6FiberAutoNegotiation OBJECT-TYPE Media converter module's current switch setting for fiber Auto-Ngotiation. This object is not applicable if there is a 100 Mbps SFP modules inserted. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.12 | INTEGER {swDownDisabled(0), swUpEnabled(1), notApplicable(2)} | read-only | current |
| cm1110HwSw6FiberSfp100Duplex OBJECT-TYPE Media converter module's current switch setting for fiber duplex if a 100 Mbps SFP module is inserted. Otherwise this object is not applicable. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.13 | INTEGER {swDownHalfDuplex(0), swUpFullDuplex(1), notApplicable(2)} | read-only | current |
| cm1110HwSw7Loopback OBJECT-TYPE Media converter module's current switch setting for fiber loopback mode. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.14 | INTEGER {swDownEnabled(0), swUpDisabled(1)} | read-only | current |
| cm1110FiberLinkStatus OBJECT-TYPE Media converter module's current fiber link status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.15 | INTEGER {down(0), up(1)} | read-only | current |
| cm1110FiberConnType OBJECT-TYPE Media converter module's fiber port connector type. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.16 | INTEGER {sc(0), lc(1), st(2), sfp(3), fc(5), mtrj(6)} | read-only | current |
| cm1110FiberAutoNegState OBJECT-TYPE Media converter module's current fiber auto-negotiation state. This object is not applicable if the fiber connector type is a 100 Mbps SFP module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.17 | INTEGER {disabled(0), complete(1), inProgress(2), notApplicable(99)} | read-only | current |
| cm1110FiberSpeed OBJECT-TYPE If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.18 | INTEGER {speed100Mbps(1), speed1000Mbps(2)} | read-only | current |
| cm1110FiberDuplex OBJECT-TYPE This object identifies the current fiber port duplex state. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.19 | INTEGER {half(0), full(1)} | read-only | current |
| cm1110FiberPauseEnh OBJECT-TYPE If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.20 | INTEGER {disabled(0), symmetrical(1), asymmetricalTx(2), asymmetricalRx(3)} | read-only | current |
| cm1110FiberLPRFStatus OBJECT-TYPE Media converter module's fiber Link Partner Remote Fault status. This object is not applicable if there is a 100 Mbps SFP module inserted. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.21 | INTEGER {ok(0), offline(1), linkFault(2), autoNegError(3), notApplicable(99)} | read-only | current |
| cm1110FiberSfp100FarEndFault OBJECT-TYPE Media converter module's current fiber Far End Fault status if a 100 Mbps SFP module is inserted. Otherwise this object is not applicable. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.22 | INTEGER {disable(0), ok(1), receivingFEF(2), sendingFEF(3), notApplicable(99)} | read-only | current |
| cm1110FiberReceiveStatus OBJECT-TYPE This object identifies the status of whether light is being received on the fiber port | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.23 | INTEGER {fault(0), ok(1)} | read-write | current |
| cm1110FiberLoopBack OBJECT-TYPE This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.24 | EnableDisableValue | read-write | current |
| cm1110CopperLinkStatus OBJECT-TYPE Media converter module's current copper link status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.25 | INTEGER {down(0), up(1)} | read-only | current |
| cm1110CopperConnType OBJECT-TYPE Media converter module's copper connector type. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.26 | INTEGER {rj45(0)} | read-only | current |
| cm1110CopperAutoNegState OBJECT-TYPE Media converter module's current copper auto-negotiation state. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.27 | INTEGER {disabled(0), complete(1), inProgress(2)} | read-only | current |
| cm1110CopperSpeed OBJECT-TYPE If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated speed setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.28 | INTEGER {speed10Mbs(0), speed100Mbps(1), speed1000Mbps(2)} | read-only | current |
| cm1110CopperDuplex OBJECT-TYPE If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.29 | INTEGER {half(0), full(1)} | read-only | current |
| cm1110CopperCrossOver OBJECT-TYPE If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated MDI/MDI-X setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.30 | INTEGER {mdi(0), mdix(1)} | read-only | current |
| cm1110CopperPauseEnh OBJECT-TYPE If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.31 | INTEGER {disabled(0), symmetrical(1), asymmetricalTx(2), asymmetricalRx(3)} | read-only | current |
| cm1110CopperLPRFStatus OBJECT-TYPE Media converter module's copper Link Partner Remote Fault status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.32 | INTEGER {ok(0), remoteFault(1)} | read-only | current |
| cm1110CopperAutoSpeedDownshift OBJECT-TYPE This object identifies the status of the copper auto speed downshift feature. noDownshift indicates that an automatic downshift of the copper speed has not occurred. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.1.1.33 | INTEGER {noDownshift(0), downshift(1)} | read-only | current |
| cm1110ConfigTable OBJECT-TYPE Table of CM-1110 type media converter module's configuration type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2 | not-accessible | current | |
| cm1110ConfigEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-1110 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1 | not-accessible | current | |
| cm1110ConfigSlotIndex OBJECT-TYPE The Slot number the CM-1110 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.2 | SlotNumber | not-accessible | current |
| cm1110ConfigStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.3 | ContainerStatus | read-write | current |
| cm1110ConfigModuleName OBJECT-TYPE This object identifies a user configurable name for the media converter module present in the chassis. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.4 | DisplayString (SIZE(0..63)) | read-write | current |
| cm1110ConfigLinkMode OBJECT-TYPE This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.5 | INTEGER {standard(0), smartLinkPassthrough(1)} | read-write | current |
| cm1110ConfigFiberFaultAlert OBJECT-TYPE This object identifies the Fiber Fault Alert setting for the media module. For 100 Mbps SFP modules, this setting is always effectively enabled if Link Mode is set to smartLinkPassthrough. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.6 | EnableDisableValue | read-write | current |
| cm1110ConfigMaxPacketsSize OBJECT-TYPE This object identifies the media converter module's maximum packet size setting This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.7 | INTEGER {maxPacket1522(0), maxPacket2048(1), maxPacket10240(2)} | read-write | current |
| cm1110ConfigFiberPortName OBJECT-TYPE This object identifies a user definable name for the fiber port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.8 | DisplayString (SIZE(0..8)) | read-write | current |
| cm1110ConfigFiberPortEnable OBJECT-TYPE This object identifies whether the fiber port is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.9 | YesNoValue | read-write | current |
| cm1110ConfigFiberAutoNegotiation OBJECT-TYPE This object identifies whether fiber auto-negotiation is enabled. This object does not apply if the fiber connector type is a 100 Mbps SFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.10 | EnableDisableValue | read-write | current |
| cm1110ConfigFiberSfp100duplex OBJECT-TYPE If the fiber connector type is SFP and it is a 100 Mbps fiber module then this object identifies the duplex setting for the 100 Mbps fiber port. Duplex for 1000 Mbps has to be auto negotiated. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.11 | INTEGER {full(0), half(1)} | read-write | current |
| cm1110ConfigCopperPortName OBJECT-TYPE This object identifies a user definable name for the copper port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.12 | DisplayString (SIZE(0..8)) | read-write | current |
| cm1110ConfigCopperPortEnable OBJECT-TYPE This object identifies whether the fiber port is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.13 | YesNoValue | read-write | current |
| cm1110ConfigCopperAutoNegotiation OBJECT-TYPE This object identifies the whether copper auto-negotiation is enabled. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.14 | EnableDisableValue | read-write | current |
| cm1110ConfigCopperAutoNegAdv10HDX OBJECT-TYPE This object controls whether or the copper port advertises willingness to connect at 10Mbps, half duplex. This setting is ignored when auto-negotiation is disabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.15 | YesNoValue | read-write | current |
| cm1110ConfigCopperAutoNegAdv10FDX OBJECT-TYPE This object controls whether or the copper port advertises willingness to connect at 10Mbps, full duplex. This setting is ignored when auto-negotiation is disabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.16 | YesNoValue | read-write | current |
| cm1110ConfigCopperAutoNegAdv100HDX OBJECT-TYPE This object controls whether or the copper port advertises willingness to connect at 100Mbps, half duplex. This setting is ignored when auto-negotiation is disabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.17 | YesNoValue | read-write | current |
| cm1110ConfigCopperAutoNegAdv100FDX OBJECT-TYPE This object controls whether or the copper port advertises willingness to connect at 100Mbps, full duplex. This setting is ignored when auto-negotiation is disabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.18 | YesNoValue | read-write | current |
| cm1110ConfigCopperAutoNegAdv1000FDX OBJECT-TYPE This object controls whether or the copper port advertises willingness to connect at 1000Mbps, full duplex. This setting is ignored when auto-negotiation is disabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.19 | YesNoValue | read-write | current |
| cm1110ConfigCopperSpeed OBJECT-TYPE If copper auto-negotiation is disabled then this object identifies the configured cooper speed. 1000 Mbps speed can only be auto negotiated. If copper auto-negotiation is enabled then this object is ignored. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.20 | INTEGER {speed10Mbs(0), speed100Mbps(1)} | read-write | current |
| cm1110ConfigCopperDuplex OBJECT-TYPE If copper auto-negotiation is disabled then this object identifies the duplex setting for 10 & 100 Mbps for the copper port. Duplex for 1000 Mbps has to be auto negotiated. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.21 | INTEGER {full(0), half(1)} | read-write | current |
| cm1110ConfigCopperCrossOver OBJECT-TYPE This object identifies the copper MDI/MDI-X setting.This object is read-only if the media converter module's ConfigMode jumper is set to | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.22 | INTEGER {auto(0), mdi(1), mdix(2)} | read-write | current |
| cm1110ConfigCopperPauseEnh OBJECT-TYPE This object identifies the copper pause (flow control) setting that is a advertised. The settings can be disabled, advertise symmetrical, advertise asymmetrical TX or advertise symmetrical and asymmetrical RX. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.23 | INTEGER {disabled(0), symmetrical(1), asymmetricalTx(2), symmAsymRx(3)} | read-write | current |
| cm1110ConfigCopperAutoSpeedDownshift OBJECT-TYPE This object identifies the number of times the PHY attempts to establish a Gigabit link before the PHY downshift to the next highest speed. A value of 0 indicates the auto downshift is disabled | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.24 | INTEGER (0..8) | read-write | current |
| cm1110ConfigCopper10BaseTDistance OBJECT-TYPE When using cable exceeding 100 meters in 10BASE-T mode this feature should be set to extended(1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.25 | INTEGER {normal(0), extended(1)} | read-write | current |
| cm1110ConfigUnidirectionalEthernet OBJECT-TYPE Restrict the flow of Ethernet traffic to a single direction. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.26 | INTEGER {notApplicable(-1), disabled(0), copperToFiber(1), fiberToCopper(2)} | read-write | current |
| cm1110ConfigPriorityToEgressQueueMap0 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.27 | INTEGER (0..3) | read-write | current |
| cm1110ConfigPriorityToEgressQueueMap1 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.28 | INTEGER (0..3) | read-write | current |
| cm1110ConfigPriorityToEgressQueueMap2 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.29 | INTEGER (0..3) | read-write | current |
| cm1110ConfigPriorityToEgressQueueMap3 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.30 | INTEGER (0..3) | read-write | current |
| cm1110ConfigPriorityToEgressQueueMap4 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.31 | INTEGER (0..3) | read-write | current |
| cm1110ConfigPriorityToEgressQueueMap5 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.32 | INTEGER (0..3) | read-write | current |
| cm1110ConfigPriorityToEgressQueueMap6 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.33 | INTEGER (0..3) | read-write | current |
| cm1110ConfigPriorityToEgressQueueMap7 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.34 | INTEGER (0..3) | read-write | current |
| cm1110ConfigCopper8021pPriority OBJECT-TYPE Use 802.1p tag priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.35 | OnOffValue | read-write | current |
| cm1110ConfigCopperIpTosPriority OBJECT-TYPE Use IP TOS priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.36 | OnOffValue | read-write | current |
| cm1110ConfigCopperPriorityPrecedence OBJECT-TYPE Configure priority precedence. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.37 | INTEGER {notApplicable(-1), priority8021p(0), priorityIpTos(1)} | read-write | current |
| cm1110ConfigCopperCongestionPolicy OBJECT-TYPE Configure priority congestion policy. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.38 | INTEGER {notApplicable(-1), strict(0), weighted(1)} | read-write | current |
| cm1110ConfigCopperPriorityMap0 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.39 | INTEGER (0..7) | read-write | current |
| cm1110ConfigCopperPriorityMap1 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.40 | INTEGER (0..7) | read-write | current |
| cm1110ConfigCopperPriorityMap2 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.41 | INTEGER (0..7) | read-write | current |
| cm1110ConfigCopperPriorityMap3 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.42 | INTEGER (0..7) | read-write | current |
| cm1110ConfigCopperPriorityMap4 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.43 | INTEGER (0..7) | read-write | current |
| cm1110ConfigCopperPriorityMap5 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.44 | INTEGER (0..7) | read-write | current |
| cm1110ConfigCopperPriorityMap6 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.45 | INTEGER (0..7) | read-write | current |
| cm1110ConfigCopperPriorityMap7 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.46 | INTEGER (0..7) | read-write | current |
| cm1110ConfigCopperIngressLimit OBJECT-TYPE Set a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.47 | INTEGER {notApplicable(-1), rateUnlimited(0), rate64kbps(1), rate128kbps(2), rate192kbps(3), rate256kbps(4), rate320kbps(5), rate384kbps(6), rate512kbps(7), rate768kbps(8), rate1mbps(9), rate2mbps(10), rate3mbps(11), rate4mbps(12), rate5mbps(13), rate6mbps(14), rate7mbps(15), rate8mbps(16), rate9mbps(17), rate10mbps(18), rate20mbps(19), rate30mbps(20), rate40mbps(21), rate50mbps(22), rate60mbps(23), rate70mbps(24), rate80mbps(25), rate90mbps(26), rate100mbps(27), rate200mbps(28), rate300mbps(29), rate400mbps(30), rate500mbps(31), rate600mbps(32), rate700mbps(33), rate800mbps(34), rate900mbps(35)} | read-write | current |
| cm1110ConfigCopperEgressLimit OBJECT-TYPE Set a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.48 | INTEGER {notApplicable(-1), rateUnlimited(0), rate64kbps(1), rate128kbps(2), rate192kbps(3), rate256kbps(4), rate320kbps(5), rate384kbps(6), rate512kbps(7), rate768kbps(8), rate1mbps(9), rate2mbps(10), rate3mbps(11), rate4mbps(12), rate5mbps(13), rate6mbps(14), rate7mbps(15), rate8mbps(16), rate9mbps(17), rate10mbps(18), rate20mbps(19), rate30mbps(20), rate40mbps(21), rate50mbps(22), rate60mbps(23), rate70mbps(24), rate80mbps(25), rate90mbps(26), rate100mbps(27), rate200mbps(28), rate300mbps(29), rate400mbps(30), rate500mbps(31), rate600mbps(32), rate700mbps(33), rate800mbps(34), rate900mbps(35)} | read-write | current |
| cm1110ConfigCopperDiscardTaggedFrames OBJECT-TYPE Enable discarding of tagged frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.49 | OnOffValue | read-write | current |
| cm1110ConfigCopperDiscardUntaggedFrames OBJECT-TYPE Enable discarding of untagged frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.50 | OnOffValue | read-write | current |
| cm1110ConfigCopperDefaultVlanId OBJECT-TYPE Set the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.51 | INTEGER (0..4095) | read-write | current |
| cm1110ConfigCopperDefaultPriority OBJECT-TYPE Set the default frame priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.52 | INTEGER (0..7) | read-write | current |
| cm1110ConfigCopperVlanTaggingAction OBJECT-TYPE Set the default tagging action. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.53 | INTEGER {notApplicable(-1), none(0), untag(1), tag(2), doubleTag(3)} | read-write | current |
| cm1110ConfigCopperFilterUnknownMulticast OBJECT-TYPE Enable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.54 | OnOffValue | read-write | current |
| cm1110ConfigCopperFilterUnknownUnicast OBJECT-TYPE Enable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.55 | OnOffValue | read-write | current |
| cm1110ConfigFiber8021pPriority OBJECT-TYPE Use 802.1p tag priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.56 | OnOffValue | read-write | current |
| cm1110ConfigFiberIpTosPriority OBJECT-TYPE Use IP TOS priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.57 | OnOffValue | read-write | current |
| cm1110ConfigFiberPriorityPrecedence OBJECT-TYPE Configure priority precedence. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.58 | INTEGER {notApplicable(-1), priority8021p(0), priorityIpTos(1)} | read-write | current |
| cm1110ConfigFiberCongestionPolicy OBJECT-TYPE Configure priority congestion policy. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.59 | INTEGER {notApplicable(-1), strict(0), weighted(1)} | read-write | current |
| cm1110ConfigFiberPriorityMap0 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.60 | INTEGER (0..7) | read-write | current |
| cm1110ConfigFiberPriorityMap1 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.61 | INTEGER (0..7) | read-write | current |
| cm1110ConfigFiberPriorityMap2 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.62 | INTEGER (0..7) | read-write | current |
| cm1110ConfigFiberPriorityMap3 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.63 | INTEGER (0..7) | read-write | current |
| cm1110ConfigFiberPriorityMap4 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.64 | INTEGER (0..7) | read-write | current |
| cm1110ConfigFiberPriorityMap5 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.65 | INTEGER (0..7) | read-write | current |
| cm1110ConfigFiberPriorityMap6 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.66 | INTEGER (0..7) | read-write | current |
| cm1110ConfigFiberPriorityMap7 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.67 | INTEGER (0..7) | read-write | current |
| cm1110ConfigFiberIngressLimit OBJECT-TYPE Set a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.68 | INTEGER {notApplicable(-1), rateUnlimited(0), rate64kbps(1), rate128kbps(2), rate192kbps(3), rate256kbps(4), rate320kbps(5), rate384kbps(6), rate512kbps(7), rate768kbps(8), rate1mbps(9), rate2mbps(10), rate3mbps(11), rate4mbps(12), rate5mbps(13), rate6mbps(14), rate7mbps(15), rate8mbps(16), rate9mbps(17), rate10mbps(18), rate20mbps(19), rate30mbps(20), rate40mbps(21), rate50mbps(22), rate60mbps(23), rate70mbps(24), rate80mbps(25), rate90mbps(26), rate100mbps(27), rate200mbps(28), rate300mbps(29), rate400mbps(30), rate500mbps(31), rate600mbps(32), rate700mbps(33), rate800mbps(34), rate900mbps(35)} | read-write | current |
| cm1110ConfigFiberEgressLimit OBJECT-TYPE Set a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.69 | INTEGER {notApplicable(-1), rateUnlimited(0), rate64kbps(1), rate128kbps(2), rate192kbps(3), rate256kbps(4), rate320kbps(5), rate384kbps(6), rate512kbps(7), rate768kbps(8), rate1mbps(9), rate2mbps(10), rate3mbps(11), rate4mbps(12), rate5mbps(13), rate6mbps(14), rate7mbps(15), rate8mbps(16), rate9mbps(17), rate10mbps(18), rate20mbps(19), rate30mbps(20), rate40mbps(21), rate50mbps(22), rate60mbps(23), rate70mbps(24), rate80mbps(25), rate90mbps(26), rate100mbps(27), rate200mbps(28), rate300mbps(29), rate400mbps(30), rate500mbps(31), rate600mbps(32), rate700mbps(33), rate800mbps(34), rate900mbps(35)} | read-write | current |
| cm1110ConfigFiberDiscardTaggedFrames OBJECT-TYPE Enable discarding of tagged frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.70 | OnOffValue | read-write | current |
| cm1110ConfigFiberDiscardUntaggedFrames OBJECT-TYPE Enable discarding of untagged frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.71 | OnOffValue | read-write | current |
| cm1110ConfigFiberDefaultVlanId OBJECT-TYPE Set the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.72 | INTEGER (0..4095) | read-write | current |
| cm1110ConfigFiberDefaultPriority OBJECT-TYPE Set the default frame priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.73 | INTEGER (0..7) | read-write | current |
| cm1110ConfigFiberVlanTaggingAction OBJECT-TYPE Set the default tagging action. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.74 | INTEGER {notApplicable(-1), none(0), untag(1), tag(2), doubleTag(3)} | read-write | current |
| cm1110ConfigFiberFilterUnknownMulticast OBJECT-TYPE Enable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.75 | OnOffValue | read-write | current |
| cm1110ConfigFiberFilterUnknownUnicast OBJECT-TYPE Enable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.76 | OnOffValue | read-write | current |
| cm1110ConfigFiberSgmiiInterface OBJECT-TYPE This object identifies whether fiber SGMII interface is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.2.1.77 | EnableDisableValue | read-write | current |
| cm1110LedTable OBJECT-TYPE Table of CM-1110 type media converter module's LED status information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3 | not-accessible | current | |
| cm1110LedEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-1110 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1 | not-accessible | current | |
| cm1110LedSlotIndex OBJECT-TYPE The Slot number the CM-1110 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.2 | SlotNumber | not-accessible | current |
| cm1110LedPWR OBJECT-TYPE This object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Fiber loopback enabled | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.3 | INTEGER {off(0), onGreen(1), blinking(2)} | read-only | current |
| cm1110LedFDF OBJECT-TYPE This object identifies the status of the Full Duplex Fiber (FDF) LED on the media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.4 | INTEGER {offHalfDuplex(0), onFullDuplex(1)} | read-only | current |
| cm1110LedLKF OBJECT-TYPE This object identifies the status of the link fiber (LKF) LED on the media converter module. Possible status values are: off(0) - No fiber link on(1) - Fiber link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.5 | INTEGER {off(0), on(1)} | read-only | current |
| cm1110LedCopperSpeed OBJECT-TYPE This object identifies the status of the link copper speed (100/1000) LED on the management module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.6 | INTEGER {off10Mbps(0), onYellow100Mbps(1), onGreen1000Mbps(2)} | read-only | current |
| cm1110LedFDC OBJECT-TYPE This object identifies the status of the Full Duplex Copper (FDC) LED on the media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.7 | INTEGER {offHalfDuplex(0), onFullDuplex(1)} | read-only | current |
| cm1110LedLKC OBJECT-TYPE This object identifies the status of the link copper (LKC) LED on the media converter module. Possible status values are: off(0) - No copper link on(1) - Copper link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.3.1.8 | INTEGER {off(0), on(1)} | read-only | current |
| cm1110RateConvStatsTable OBJECT-TYPE Table of CM-1110 type media converter module's configuration and status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4 | not-accessible | current | |
| cm1110RateConvStatsEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-1110 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1 | not-accessible | current | |
| cm1110StatsSlotIndex OBJECT-TYPE The Slot number the CM-1110 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.2 | SlotNumber | not-accessible | current |
| cm1110MediaPortIndex OBJECT-TYPE Media converter module port index indicating which media port the statistical counters are associated with. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.3 | INTEGER {copper(1), fiber(2)} | not-accessible | current |
| cm1110PortInDiscards OBJECT-TYPE A counter that counts the number of good, non-filtered frames that normally would have been forwarded, but could not due to lack of buffer space. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.4 | Counter32 | read-only | current |
| cm1110PortInFiltered OBJECT-TYPE A counter that counts the number of good frames that were filtered due to ingress switch policy rules. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.5 | INTEGER (0..65535) | read-only | current |
| cm1110PortInGoodOctets OBJECT-TYPE An ingress counter that is the sum of lengths of all good Ethernet frames received on the media port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.6 | Counter32 | read-only | current |
| cm1110PortHCInGoodOctets OBJECT-TYPE An ingress counter that is the sum of lengths of all good Ethernet frames received on the media port. This object is a 64-bit version of cm1110PortInGoodOctets. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.7 | Counter64 | read-only | current |
| cm1110PortInBadOctets OBJECT-TYPE An ingress counter that is the sum of lengths of all bad Ethernet frames received on the media port.. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.8 | Counter32 | read-only | current |
| cm1110PortInUnicasts OBJECT-TYPE An ingress counter that counts the number of good frames received that have a Unicast destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.9 | Counter32 | read-only | current |
| cm1110PortInBroadcasts OBJECT-TYPE An ingress counter that counts the number of good frames received that have a Broadcast destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.10 | Counter32 | read-only | current |
| cm1110PortInMulticasts OBJECT-TYPE An ingress counter that counts the number of good frames received that have a Multicast destination MAC address. This count does not include frames counted in the cm1110PortInPauses or the cm1110PortInBroadcasts objects. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.11 | Counter32 | read-only | current |
| cm1110PortInPauses OBJECT-TYPE An ingress counter that counts the number of good frames reachieved that have a Pause destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.12 | Counter32 | read-only | current |
| cm1110PortInUnderSizes OBJECT-TYPE An ingress counter that counts the number of frames received with a length less that 64 octets but with a valid FCS. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.13 | Counter32 | read-only | current |
| cm1110PortInFragments OBJECT-TYPE An ingress counter that counts the number of frames received with a length less that 64 octets and an invalid FCS. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.14 | Counter32 | read-only | current |
| cm1110PortInOversizes OBJECT-TYPE An ingress counter that counts the number of frames received with a length more than the maximum packet size but with a valid FCS. The maximum packet size can be set using the cm1110ConfigMaxPacketsSize object. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.15 | Counter32 | read-only | current |
| cm1110PortInJabbers OBJECT-TYPE An ingress counter that counts the number of frames received with a length more than the maximum packet size but with a invalid FCS. The maximum packet size can be set using the cm1110ConfigMaxPacketsSize object. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.16 | Counter32 | read-only | current |
| cm1110PortInRxErrs OBJECT-TYPE An ingress counter that counts the number of frames received with an RxErr signal from the PHY. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.17 | Counter32 | read-only | current |
| cm1110PortInFcsErrs OBJECT-TYPE An ingress counter that counts the number of frames received with a CRC error not counted in the cm1110PortInFragments, cm1110PortInFcsErr, or the cm1110PortInRxErr objects. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.18 | Counter32 | read-only | current |
| cm1110PortPkts64Octets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of exactly 64 Octets, including those with errors. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.19 | Counter32 | read-only | current |
| cm1110PortPkts65to127Octets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of between 65 and 127 Octets inclusive, including those with errors. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.20 | Counter32 | read-only | current |
| cm1110PortPkts128to255Octets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of between 128 and 255 Octets inclusive, including those with errors. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.21 | Counter32 | read-only | current |
| cm1110PortPkts256to511Octets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of between 256 and 511 Octets inclusive, including those with errors. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.22 | Counter32 | read-only | current |
| cm1110PortPkts512to1023Octets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of between 512 and 1023 Octets inclusive, including those with errors. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.23 | Counter32 | read-only | current |
| cm1110PortPkts1024toMaxOctets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of between 1024 and maximum packet size octets inclusive, including those with errors. The maximum packet size can be set using the cm1110ConfigMaxPacketsSize object. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.24 | Counter32 | read-only | current |
| cm1110PortOutOctets OBJECT-TYPE An Egress counter that is the sum of lengths of all good Ethernet frames sent on the media port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.25 | Counter32 | read-only | current |
| cm1110PortHCOutOctets OBJECT-TYPE An Egress counter that is the sum of lengths of all good Ethernet frames sent on the media port. This object is a 64-bit version of cm1110PortOutOctets. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.26 | Counter64 | read-only | current |
| cm1110PortOutFiltered OBJECT-TYPE A counter that counts the number of good frames that were filtered due to egress switch policy rules. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.27 | INTEGER (0..65535) | read-only | current |
| cm1110PortOutUnicasts OBJECT-TYPE An Egress counter that counts the number of good frames sent that have a Unicast destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.28 | Counter32 | read-only | current |
| cm1110PortOutBroadcasts OBJECT-TYPE An Egress counter that counts the number of good frames sent that have a Broadcast destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.29 | Counter32 | read-only | current |
| cm1110PortOutMulticasts OBJECT-TYPE An Egress counter that counts the number of good frames sent that have a Multicast destination MAC address. This count does not include frames counted in the cm1110PortOutPauses or the cm1110PortOutBroadcasts objects. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.30 | Counter32 | read-only | current |
| cm1110PortOutPauses OBJECT-TYPE An Egress counter that counts the number of good frames reachieved that have a Pause destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.31 | Counter32 | read-only | current |
| cm1110PortDeferreds OBJECT-TYPE An Egress counter that counts the number of successfully transmitted frames that experienced no collisions but are delayed because the medium was busy during the first attempt. This counter is applicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.32 | Counter32 | read-only | current |
| cm1110PortCollisions OBJECT-TYPE An Egress counter that counts the number of collision events seen by the MAC not including those counted in cm1110PortSingles, cm1110PortMultiple , cm1110PortExcessives or cm1110PortLates objects. This counter is applicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.33 | Counter32 | read-only | current |
| cm1110PortSingles OBJECT-TYPE An Egress counter that counts the number of successfully transmitted frames that experienced exactly one collision. This counter is applicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.34 | Counter32 | read-only | current |
| cm1110PortMultiples OBJECT-TYPE An Egress counter that counts the number of successfully transmitted frames that experienced more than one collision. This counter is aplicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.35 | Counter32 | read-only | current |
| cm1110PortExcessives OBJECT-TYPE An Egress counter that counts the number frames dropped in the transmit MAC because the frame experienced 16 consecutive collisions. This counter is applicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.36 | Counter32 | read-only | current |
| cm1110PortLates OBJECT-TYPE An Egress counter that counts the number times a collision is detected later than 512 bits-times into the transmission of a frame. This counter is applicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.37 | Counter32 | read-only | current |
| cm1110PortOutFcsErrs OBJECT-TYPE An Egress counter that counts the number frames transmitted with an invalid FCS. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.38 | Counter32 | read-only | current |
| cm1110PortResetCounters OBJECT-TYPE Allows the resetting of all cm1110RateConvStats statistical counters for this port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.4.1.39 | YesNoValue | read-write | current |
| cm1110RateConvAvctTable OBJECT-TYPE Table of CM-1110 type media converter module's | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5 | not-accessible | current | |
| cm1110RateConvAvctEntry OBJECT-TYPE Entries of the table, each relating to a separate fiber or copper port on the CM-1110 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1 | not-accessible | current | |
| cm1110AvctSlotIndex OBJECT-TYPE The Slot number the CM-1110 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.2 | SlotNumber | not-accessible | current |
| cm1110AvctStart OBJECT-TYPE Set this self-clearing variable to yes initiate the Advanced Virtual Cable Test. Note: During the test, no network data will be passed. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.3 | YesNoValue | read-write | current |
| cm1110AvctStatus OBJECT-TYPE This object identifies the state of the Advanced Virtual Cable Tester. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.4 | INTEGER {notStarted(0), inProgress(1), testComplete(2)} | read-only | current |
| cm1110AvctTxRxPair1Results OBJECT-TYPE Test result code returned from Virtual Cable Test of the Tx/Rx pair one. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.5 | INTEGER {normal(0), shortDetected(1), openDetected(2), testFailed(3)} | read-only | current |
| cm1110AvctTxRxPair1Amplitude OBJECT-TYPE Amplitude of Tx/Rx pair one in millivolts when test result codes is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.6 | DisplayString (SIZE(0..20)) | read-only | current |
| cm1110AvctTxRxPair1Distance OBJECT-TYPE Distance in meters to fault when test result codes for Tx/Rx pair one is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.7 | DisplayString (SIZE(0..20)) | read-only | current |
| cm1110AvctTxRxPair2Results OBJECT-TYPE Test result code returned from Virtual Cable Test of the Tx/Rx pair two. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.8 | INTEGER {normal(0), shortDetected(1), openDetected(2), testFailed(3)} | read-only | current |
| cm1110AvctTxRxPair2Amplitude OBJECT-TYPE Amplitude of Tx/Rx pair two in millivolts when test result codes is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.9 | DisplayString (SIZE(0..20)) | read-only | current |
| cm1110AvctTxRxPair2Distance OBJECT-TYPE Distance in meters to fault when test result codes for Tx/Rx pair two is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.10 | DisplayString (SIZE(0..20)) | read-only | current |
| cm1110AvctTxRxPair3Results OBJECT-TYPE Test result code returned from Virtual Cable Test of the Tx/Rx pair three. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.11 | INTEGER {normal(0), shortDetected(1), openDetected(2), testFailed(3)} | read-only | current |
| cm1110AvctTxRxPair3Amplitude OBJECT-TYPE Amplitude of Tx/Rx pair three in millivolts when test result codes is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.12 | DisplayString (SIZE(0..20)) | read-only | current |
| cm1110AvctTxRxPair3Distance OBJECT-TYPE Distance in meters to fault when test result codes for Tx/Rx pair three is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.13 | DisplayString (SIZE(0..20)) | read-only | current |
| cm1110AvctTxRxPair4Results OBJECT-TYPE Test result code returned from Virtual Cable Test of Tx/Rx pair four. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.14 | INTEGER {normal(0), shortDetected(1), openDetected(2), testFailed(3)} | read-only | current |
| cm1110AvctTxRxPair4Amplitude OBJECT-TYPE Amplitude of Tx/Rx pair four in millivolts when test result codes is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.15 | DisplayString (SIZE(0..20)) | read-only | current |
| cm1110AvctTxRxPair4Distance OBJECT-TYPE Distance in meters to fault when test result codes for Tx/Rx pair four is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.3.5.1.16 | DisplayString (SIZE(0..20)) | read-only | current |
| cm110RateConv OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4 | |||
| cm110RateConvTable OBJECT-TYPE Table of CM-110 type media converter module's configuration and status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1 | not-accessible | current | |
| cm110RateConvEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-110 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1 | not-accessible | current | |
| cm110SlotIndex OBJECT-TYPE The Slot number the CM-110 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.2 | SlotNumber | not-accessible | current |
| cm110Modelname OBJECT-TYPE This object identifies the model of media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.3 | DisplayString | read-only | current |
| cm110ModelDesc OBJECT-TYPE This object identifies a static description of the media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.4 | DisplayString | read-only | current |
| cm110HwJmp5ConfigMode OBJECT-TYPE This object identifies the media converter module's ConfigMode, set by hardware switch on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media module's hardware switches or jumpers. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.5 | INTEGER {hardwareSwitches(0), auto(1)} | read-only | current |
| cm110HwJmp6AutoMDIX OBJECT-TYPE This object identifies the media converter module's hardware Auto MDIX jumper settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.6 | INTEGER {mdix(0), auto(1)} | read-only | current |
| cm110HwSw1TpAutoNegotiation OBJECT-TYPE Media converter module's current switch setting for copper auto-negotiation. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.7 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| cm110HwSw2LinkMode OBJECT-TYPE Media converter module's current switch setting for Link Mode. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.8 | INTEGER {swDownNormalMode(0), swUpSmartLinkPassthroughMode(1)} | read-only | current |
| cm110HwSw3FarEndFault OBJECT-TYPE Media converter module's current switch setting for Far End Fault. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.9 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| cm110HwSw4TpDuplex OBJECT-TYPE Media converter module's current switch setting for copper duplex. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.10 | INTEGER {swDownHalf(0), swUpFull(1)} | read-only | current |
| cm110HwSw5TpSpeed OBJECT-TYPE Media converter module's current switch setting for Link Mode. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.11 | INTEGER {swDown10Mbps(0), swUp100Mbps(1)} | read-only | current |
| cm110HwSw6FiberDuplex OBJECT-TYPE Media converter module's current switch setting for fiber duplex. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.12 | INTEGER {swDownHalf(0), swUpFull(1)} | read-only | current |
| cm110HwSw7Loopback OBJECT-TYPE Media converter module's current switch setting for fiber loopback mode. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.13 | INTEGER {swDownEnabled(0), swUpDisabled(1)} | read-only | current |
| cm110FiberLinkStatus OBJECT-TYPE Media converter module's current fiber link status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.14 | INTEGER {down(0), up(1)} | read-only | current |
| cm110FiberConnType OBJECT-TYPE Media converter module's fiber port connector type. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.15 | INTEGER {sc(0), lc(1), st(2), sfp(3), fc(5), mtrj(6)} | read-only | current |
| cm110FiberSpeed OBJECT-TYPE Media converter module's fiber port speed in megabits per second. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.16 | INTEGER {speed100Mbps(1)} | read-only | current |
| cm110FiberFarEndFault OBJECT-TYPE Media converter module's current fiber Far End Fault status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.17 | INTEGER {disable(0), ok(1), receivingFEF(2), sendingFEF(3)} | read-only | current |
| cm110FiberReceiveStatus OBJECT-TYPE This object identifies the status of whether light is being received on the fiber port | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.18 | INTEGER {fault(0), ok(1)} | read-write | current |
| cm110FiberLoopBack OBJECT-TYPE This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.19 | EnableDisableValue | read-write | current |
| cm110CopperLinkStatus OBJECT-TYPE Media converter module's current copper link status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.20 | INTEGER {down(0), up(1)} | read-only | current |
| cm110CopperConnType OBJECT-TYPE Media converter module's copper connector type. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.21 | INTEGER {rj45(0)} | read-only | current |
| cm110CopperAutoNegState OBJECT-TYPE Media converter module's current copper auto-negotiation state. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.22 | INTEGER {disabled(0), complete(1), inProgress(2)} | read-only | current |
| cm110CopperSpeed OBJECT-TYPE If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated speed setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.23 | INTEGER {speed10Mbs(0), speed100Mbps(1)} | read-only | current |
| cm110CopperDuplex OBJECT-TYPE If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.24 | INTEGER {half(0), full(1)} | read-only | current |
| cm110CopperCrossOver OBJECT-TYPE If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated MDI/MDI-X setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.25 | INTEGER {mdi(0), mdix(1)} | read-only | current |
| cm110CopperPause OBJECT-TYPE If copper auto-negotiation state is complete then this object indicates the media converter module's current copper auto-negotiated pause (flow control) setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.26 | INTEGER {disabled(0), symmetrical(1)} | read-only | current |
| cm110CopperLPRFStatus OBJECT-TYPE Media converter module's fiber Link Partner Remote Fault status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.1.1.27 | INTEGER {ok(0), remoteFault(1)} | read-only | current |
| cm110ConfigTable OBJECT-TYPE Table of CM-110 type media converter module's configuration and status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2 | not-accessible | current | |
| cm110ConfigEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-110 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1 | not-accessible | current | |
| cm110ConfigSlotIndex OBJECT-TYPE The Slot number the CM-110 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.2 | SlotNumber | not-accessible | current |
| cm110ConfigStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.3 | ContainerStatus | read-write | current |
| cm110ConfigModuleName OBJECT-TYPE This object identifies a user configurable name for the media converter module present in the chassis. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.4 | DisplayString (SIZE(0..63)) | read-write | current |
| cm110ConfigLinkMode OBJECT-TYPE This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.5 | INTEGER {standard(0), linkPassthrough(1)} | read-write | current |
| cm110ConfigFiberFarEndFault OBJECT-TYPE This object identifies the Fiber Fault Alert setting for the media module. This setting is always enabled if Link Mode is set to linkPassthrough. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.6 | INTEGER {disable(0), enable(1)} | read-write | current |
| cm110ConfigMaxPacketSize OBJECT-TYPE This object identifies the media converter module's maximum packet size setting This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.7 | INTEGER {maxpacket1522(0), maxpacket2048(1)} | read-write | current |
| cm110ConfigFiberPortName OBJECT-TYPE This object identifies a user definable name for the fiber port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.8 | DisplayString (SIZE(0..8)) | read-write | current |
| cm110ConfigFiberPortEnable OBJECT-TYPE This object identifies whether the fiber port is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.9 | YesNoValue | read-write | current |
| cm110ConfigFiberDuplex OBJECT-TYPE This object identifies the fiber port duplex setting. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.10 | INTEGER {full(0), half(1)} | read-only | current |
| cm110ConfigCopperPortName OBJECT-TYPE This object identifies a user definable name for the copper port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.11 | DisplayString (SIZE(0..8)) | read-write | current |
| cm110ConfigCopperPortEnable OBJECT-TYPE This object identifies whether the fiber port is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.12 | YesNoValue | read-write | current |
| cm110ConfigCopperAutoNegotiation OBJECT-TYPE This object identifies the whether copper auto-negotiation is enabled. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.13 | INTEGER {disable(0), enable(1)} | read-write | current |
| cm110ConfigCopperAutoNegAdv10HDX OBJECT-TYPE This object controls whether or the copper port advertises willingness to connect at 10Mbps, half duplex. This setting is ignored when auto-negotiation is disabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.14 | YesNoValue | read-write | current |
| cm110ConfigCopperAutoNegAdv10FDX OBJECT-TYPE This object controls whether or the copper port advertises willingness to connect at 10Mbps, full duplex. This setting is ignored when auto-negotiation is disabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.15 | YesNoValue | read-write | current |
| cm110ConfigCopperAutoNegAdv100HDX OBJECT-TYPE This object controls whether or the copper port advertises willingness to connect at 100Mbps, half duplex. This setting is ignored when auto-negotiation is disabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.16 | YesNoValue | read-write | current |
| cm110ConfigCopperAutoNegAdv100FDX OBJECT-TYPE This object controls whether or the copper port advertises willingness to connect at 100Mbps, full duplex. This setting is ignored when auto-negotiation is disabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.17 | YesNoValue | read-write | current |
| cm110ConfigCopperSpeed OBJECT-TYPE This object identifies the current copper speed in megabits per second. This object is ignored if auto-negotiation is enabled. This object is ignored if auto-negotiation is enabled | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.18 | INTEGER {speed10Mbs(0), speed100Mbps(1)} | read-write | current |
| cm110ConfigCopperDuplex OBJECT-TYPE This object identifies the copper duplex setting. This object is ignored if auto-negotiation is enabled This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.19 | INTEGER {full(0), half(1)} | read-write | current |
| cm110ConfigCopperCrossOver OBJECT-TYPE This object identifies the copper MDI/MDI-X setting.This object is read-only if the media converter module's ConfigMode jumper is set to | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.20 | INTEGER {auto(0), mdi(1), mdix(2)} | read-write | current |
| cm110ConfigCopperPause OBJECT-TYPE This object identifies the copper's pause (flow control) settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.21 | INTEGER {disabled(0), enable(1)} | read-write | current |
| cm110ConfigCopperExtendDistance OBJECT-TYPE When using cable exceeding 100 meters, the 10BASE-T this feature should be enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.22 | EnableDisableValue | read-write | current |
| cm110ConfigUnidirectionalEthernet OBJECT-TYPE Restrict the flow of Ethernet traffic to a single direction. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.23 | INTEGER {notApplicable(-1), disabled(0), copperToFiber(1), fiberToCopper(2)} | read-write | current |
| cm110ConfigPriorityToEgressQueueMap0 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.24 | INTEGER (0..3) | read-write | current |
| cm110ConfigPriorityToEgressQueueMap1 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.25 | INTEGER (0..3) | read-write | current |
| cm110ConfigPriorityToEgressQueueMap2 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.26 | INTEGER (0..3) | read-write | current |
| cm110ConfigPriorityToEgressQueueMap3 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.27 | INTEGER (0..3) | read-write | current |
| cm110ConfigPriorityToEgressQueueMap4 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.28 | INTEGER (0..3) | read-write | current |
| cm110ConfigPriorityToEgressQueueMap5 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.29 | INTEGER (0..3) | read-write | current |
| cm110ConfigPriorityToEgressQueueMap6 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.30 | INTEGER (0..3) | read-write | current |
| cm110ConfigPriorityToEgressQueueMap7 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.31 | INTEGER (0..3) | read-write | current |
| cm110ConfigCopper8021pPriority OBJECT-TYPE Use 802.1p tag priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.32 | OnOffValue | read-write | current |
| cm110ConfigCopperIpTosPriority OBJECT-TYPE Use IP TOS priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.33 | OnOffValue | read-write | current |
| cm110ConfigCopperPriorityPrecedence OBJECT-TYPE Configure priority precedence. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.34 | INTEGER {notApplicable(-1), priority8021p(0), priorityIpTos(1)} | read-write | current |
| cm110ConfigCopperCongestionPolicy OBJECT-TYPE Configure priority congestion policy. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.35 | INTEGER {notApplicable(-1), strict(0), weighted(1)} | read-write | current |
| cm110ConfigCopperPriorityMap0 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.36 | INTEGER (0..7) | read-write | current |
| cm110ConfigCopperPriorityMap1 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.37 | INTEGER (0..7) | read-write | current |
| cm110ConfigCopperPriorityMap2 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.38 | INTEGER (0..7) | read-write | current |
| cm110ConfigCopperPriorityMap3 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.39 | INTEGER (0..7) | read-write | current |
| cm110ConfigCopperPriorityMap4 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.40 | INTEGER (0..7) | read-write | current |
| cm110ConfigCopperPriorityMap5 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.41 | INTEGER (0..7) | read-write | current |
| cm110ConfigCopperPriorityMap6 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.42 | INTEGER (0..7) | read-write | current |
| cm110ConfigCopperPriorityMap7 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.43 | INTEGER (0..7) | read-write | current |
| cm110ConfigCopperIngressLimit OBJECT-TYPE Set a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.44 | INTEGER {notApplicable(-1), rateUnlimited(0), rate64kbps(1), rate128kbps(2), rate192kbps(3), rate256kbps(4), rate320kbps(5), rate384kbps(6), rate512kbps(7), rate768kbps(8), rate1mbps(9), rate2mbps(10), rate3mbps(11), rate4mbps(12), rate5mbps(13), rate6mbps(14), rate7mbps(15), rate8mbps(16), rate9mbps(17), rate10mbps(18), rate20mbps(19), rate30mbps(20), rate40mbps(21), rate50mbps(22), rate60mbps(23), rate70mbps(24), rate80mbps(25), rate90mbps(26)} | read-write | current |
| cm110ConfigCopperEgressLimit OBJECT-TYPE Set a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.45 | INTEGER {notApplicable(-1), rateUnlimited(0), rate64kbps(1), rate128kbps(2), rate192kbps(3), rate256kbps(4), rate320kbps(5), rate384kbps(6), rate512kbps(7), rate768kbps(8), rate1mbps(9), rate2mbps(10), rate3mbps(11), rate4mbps(12), rate5mbps(13), rate6mbps(14), rate7mbps(15), rate8mbps(16), rate9mbps(17), rate10mbps(18), rate20mbps(19), rate30mbps(20), rate40mbps(21), rate50mbps(22), rate60mbps(23), rate70mbps(24), rate80mbps(25), rate90mbps(26)} | read-write | current |
| cm110ConfigCopperDiscardTaggedFrames OBJECT-TYPE Enable discarding of tagged frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.46 | OnOffValue | read-write | current |
| cm110ConfigCopperDiscardUntaggedFrames OBJECT-TYPE Enable discarding of untagged frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.47 | OnOffValue | read-write | current |
| cm110ConfigCopperDefaultVlanId OBJECT-TYPE Set the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.48 | INTEGER (0..4095) | read-write | current |
| cm110ConfigCopperDefaultPriority OBJECT-TYPE Set the default frame priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.49 | INTEGER (0..7) | read-write | current |
| cm110ConfigCopperVlanTaggingAction OBJECT-TYPE Set the default tagging action. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.50 | INTEGER {notApplicable(-1), none(0), untag(1), tag(2), doubleTag(3)} | read-write | current |
| cm110ConfigCopperFilterUnknownMulticast OBJECT-TYPE Enable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.51 | OnOffValue | read-write | current |
| cm110ConfigCopperFilterUnknownUnicast OBJECT-TYPE Enable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.52 | OnOffValue | read-write | current |
| cm110ConfigFiber8021pPriority OBJECT-TYPE Use 802.1p tag priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.53 | OnOffValue | read-write | current |
| cm110ConfigFiberIpTosPriority OBJECT-TYPE Use IP TOS priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.54 | OnOffValue | read-write | current |
| cm110ConfigFiberPriorityPrecedence OBJECT-TYPE Configure priority precedence. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.55 | INTEGER {notApplicable(-1), priority8021p(0), priorityIpTos(1)} | read-write | current |
| cm110ConfigFiberCongestionPolicy OBJECT-TYPE Configure priority congestion policy. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.56 | INTEGER {notApplicable(-1), strict(0), weighted(1)} | read-write | current |
| cm110ConfigFiberPriorityMap0 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.57 | INTEGER (0..7) | read-write | current |
| cm110ConfigFiberPriorityMap1 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.58 | INTEGER (0..7) | read-write | current |
| cm110ConfigFiberPriorityMap2 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.59 | INTEGER (0..7) | read-write | current |
| cm110ConfigFiberPriorityMap3 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.60 | INTEGER (0..7) | read-write | current |
| cm110ConfigFiberPriorityMap4 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.61 | INTEGER (0..7) | read-write | current |
| cm110ConfigFiberPriorityMap5 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.62 | INTEGER (0..7) | read-write | current |
| cm110ConfigFiberPriorityMap6 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.63 | INTEGER (0..7) | read-write | current |
| cm110ConfigFiberPriorityMap7 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.64 | INTEGER (0..7) | read-write | current |
| cm110ConfigFiberIngressLimit OBJECT-TYPE Set a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.65 | INTEGER {notApplicable(-1), rateUnlimited(0), rate64kbps(1), rate128kbps(2), rate192kbps(3), rate256kbps(4), rate320kbps(5), rate384kbps(6), rate512kbps(7), rate768kbps(8), rate1mbps(9), rate2mbps(10), rate3mbps(11), rate4mbps(12), rate5mbps(13), rate6mbps(14), rate7mbps(15), rate8mbps(16), rate9mbps(17), rate10mbps(18), rate20mbps(19), rate30mbps(20), rate40mbps(21), rate50mbps(22), rate60mbps(23), rate70mbps(24), rate80mbps(25), rate90mbps(26)} | read-write | current |
| cm110ConfigFiberEgressLimit OBJECT-TYPE Set a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.66 | INTEGER {notApplicable(-1), rateUnlimited(0), rate64kbps(1), rate128kbps(2), rate192kbps(3), rate256kbps(4), rate320kbps(5), rate384kbps(6), rate512kbps(7), rate768kbps(8), rate1mbps(9), rate2mbps(10), rate3mbps(11), rate4mbps(12), rate5mbps(13), rate6mbps(14), rate7mbps(15), rate8mbps(16), rate9mbps(17), rate10mbps(18), rate20mbps(19), rate30mbps(20), rate40mbps(21), rate50mbps(22), rate60mbps(23), rate70mbps(24), rate80mbps(25), rate90mbps(26)} | read-write | current |
| cm110ConfigFiberDiscardTaggedFrames OBJECT-TYPE Enable discarding of tagged frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.67 | OnOffValue | read-write | current |
| cm110ConfigFiberDiscardUntaggedFrames OBJECT-TYPE Enable discarding of untagged frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.68 | OnOffValue | read-write | current |
| cm110ConfigFiberDefaultVlanId OBJECT-TYPE Set the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.69 | INTEGER (0..4095) | read-write | current |
| cm110ConfigFiberDefaultPriority OBJECT-TYPE Set the default frame priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.70 | INTEGER (0..7) | read-write | current |
| cm110ConfigFiberVlanTaggingAction OBJECT-TYPE Set the default tagging action. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.71 | INTEGER {notApplicable(-1), none(0), untag(1), tag(2), doubleTag(3)} | read-write | current |
| cm110ConfigFiberFilterUnknownMulticast OBJECT-TYPE Enable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.72 | OnOffValue | read-write | current |
| cm110ConfigFiberFilterUnknownUnicast OBJECT-TYPE Enable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.2.1.73 | OnOffValue | read-write | current |
| cm110LedTable OBJECT-TYPE Table of CM-110 type media converter module's LED status information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3 | not-accessible | current | |
| cm110LedEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-110 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1 | not-accessible | current | |
| cm110LedSlotIndex OBJECT-TYPE The Slot number the CM-110 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.2 | SlotNumber | not-accessible | current |
| cm110LedPWR OBJECT-TYPE This object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Fiber loopback enabled | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.3 | INTEGER {off(0), onGreen(1), blinking(2)} | read-only | current |
| cm110LedFDF OBJECT-TYPE This object identifies the status of the Full Duplex Fiber (FDF) LED on the media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.4 | INTEGER {offHalfDuplex(0), onFullDuplex(1)} | read-only | current |
| cm110LedLKF OBJECT-TYPE This object identifies the status of the link fiber (LKF) LED on the media converter module. Possible status values are: off(0) - No fiber link on(1) - Fiber link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.5 | INTEGER {off(0), on(1)} | read-only | current |
| cm110LedCopperSpeed OBJECT-TYPE This object identifies the status of the link copper speed (100/1000) LED on the media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.6 | INTEGER {off10Mbps(0), onGreen100Mbps(1)} | read-only | current |
| cm110LedFDC OBJECT-TYPE This object identifies the status of the Full Duplex Copper (FDC) LED on the media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.7 | INTEGER {offHalfDuplex(0), onFullDuplex(1)} | read-only | current |
| cm110LedLKC OBJECT-TYPE This object identifies the status of the link copper (LKC) LED on the media converter module. Possible status values are: off(0) - No copper link on(1) - Copper link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.3.1.8 | INTEGER {off(0), on(1)} | read-only | current |
| cm110RateConvStatsTable OBJECT-TYPE Table of CM-110 media converter module's configuration and status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4 | not-accessible | current | |
| cm110RateConvStatsEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-110 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1 | not-accessible | current | |
| cm110StatsSlotIndex OBJECT-TYPE The Slot number the CM-110 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.2 | SlotNumber | not-accessible | current |
| cm110MediaPortIndex OBJECT-TYPE Media converter module port index indicating which media port the statistical counters are associated with. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.3 | INTEGER {copper(1), fiber(2)} | not-accessible | current |
| cm110PortRxErrors OBJECT-TYPE Total number of bad frames received. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.4 | INTEGER (0..65535) | read-only | current |
| cm110PortTxCollisions OBJECT-TYPE Total number of TX collisions encountered. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.5 | INTEGER (0..65535) | read-only | current |
| cm110PortInFiltered OBJECT-TYPE A counter that counts the number of good frames that were filtered due to ingress switch policy rules. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.6 | INTEGER (0..65535) | read-only | current |
| cm110PortInGoodOctets OBJECT-TYPE An ingress counter that is the sum of lengths of all good Ethernet frames received on the media port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.7 | Counter32 | read-only | current |
| cm110PortInBadOctets OBJECT-TYPE An ingress counter that is the sum of lengths of all bad Ethernet frames received on the media port.. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.8 | Counter32 | read-only | current |
| cm110PortInUnicasts OBJECT-TYPE An ingress counter that counts the number of good frames received that have a Unicast destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.9 | Counter32 | read-only | current |
| cm110PortInBroadcasts OBJECT-TYPE An ingress counter that counts the number of good frames received that have a Broadcast destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.10 | Counter32 | read-only | current |
| cm110PortInMulticasts OBJECT-TYPE An ingress counter that counts the number of good frames received that have a Multicast destination MAC address. This count does not include frames counted in the cm1110PortInPauses or the cm1110PortInBroadcasts objects. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.11 | Counter32 | read-only | current |
| cm110PortInPauses OBJECT-TYPE An ingress counter that counts the number of good frames received that have a Pause destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.12 | Counter32 | read-only | current |
| cm110PortInUnderSizes OBJECT-TYPE An ingress counter that counts the number of frames received with a length less that 64 octets but with a valid FCS. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.13 | Counter32 | read-only | current |
| cm110PortInFragments OBJECT-TYPE An ingress counter that counts the number of frames received with a length less that 64 octets and an invalid FCS. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.14 | Counter32 | read-only | current |
| cm110PortInOversizes OBJECT-TYPE An ingress counter that counts the number of frames received with a length more than the maximum packet size but with a valid FCS. The maximum packet size can be set using the cm110ConfigMaxPacketsSize object. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.15 | Counter32 | read-only | current |
| cm110PortInJabbers OBJECT-TYPE An ingress counter that counts the number of frames received with a length more than the maximum packet size but with a invalid FCS. The maximum packet size can be set using the cm110ConfigMaxPacketsSize object. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.16 | Counter32 | read-only | current |
| cm110PortInMACRcvErrs OBJECT-TYPE An ingress counter of the number of Rx errors on the receive side of the MAC | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.17 | Counter32 | read-only | current |
| cm110PortInFcsErrs OBJECT-TYPE An ingress counter of the number of FCS Errors. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.18 | Counter32 | read-only | current |
| cm110PortPkts64Octets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of exactly 64 Octets, including those with errors. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.19 | Counter32 | read-only | current |
| cm110PortPkts65to127Octets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of between 65 and 127 Octets inclusive, including those with errors. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.20 | Counter32 | read-only | current |
| cm110PortPkts128to255Octets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of between 128 and 255 Octets inclusive, including those with errors. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.21 | Counter32 | read-only | current |
| cm110PortPkts256to511Octets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of between 256 and 511 Octets inclusive, including those with errors. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.22 | Counter32 | read-only | current |
| cm110PortPkts512to1023Octets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of between 512 and 1023 Octets inclusive, including those with errors. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.23 | Counter32 | read-only | current |
| cm110PortPkts1024toMaxOctets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of between 1024 and maximum packet size octets inclusive, including those with errors. The maximum packet size can be set using the cm1110ConfigMaxPacketsSize object. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.24 | Counter32 | read-only | current |
| cm110PortOutOctets OBJECT-TYPE An Egress counter that is the sum of lengths of all good Ethernet frames sent on the media port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.25 | Counter32 | read-only | current |
| cm110PortOutUnicasts OBJECT-TYPE An Egress counter that counts the number of good frames sent that have a Unicast destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.26 | Counter32 | read-only | current |
| cm110PortOutBroadcasts OBJECT-TYPE An Egress counter that counts the number of good frames sent that have a Broadcast destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.27 | Counter32 | read-only | current |
| cm110PortOutMulticasts OBJECT-TYPE An Egress counter that counts the number of good frames sent that have a Multicast destination MAC address. This count does not include frames counted in the cm1110PortOutPauses or the cm1110PortOutBroadcasts objects. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.28 | Counter32 | read-only | current |
| cm110PortOutPauses OBJECT-TYPE An Egress counter that counts the number of good frames received that have a Pause destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.29 | Counter32 | read-only | current |
| cm110PortDeferreds OBJECT-TYPE An Egress counter that counts the number of successfully transmitted frames that experienced no collsions but are delayed because the medium was busy during the first attempt. This counter is applicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.30 | Counter32 | read-only | current |
| cm110PortCollisions OBJECT-TYPE An Egress counter that counts the number of collision events seen by the MAC not including those counted in cm110PortSingles, cm110PortMultiple , cm1110PortExcessives or cm110PortLates objects. This counter is applicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.31 | Counter32 | read-only | current |
| cm110PortSingles OBJECT-TYPE An Egress counter that counts the number of successfully transmitted frames that experienced exactly one collision. This counter is applicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.32 | Counter32 | read-only | current |
| cm110PortMultiples OBJECT-TYPE An Egress counter that counts the number of successfully transmitted frames that experienced more than one collision. This counter is aplicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.33 | Counter32 | read-only | current |
| cm110PortExcessives OBJECT-TYPE An Egress counter that counts the number frames dropped in the transmit MAC because the frame experienced 16 consecutive collisions. This counter is applicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.34 | Counter32 | read-only | current |
| cm110PortLates OBJECT-TYPE An Egress counter that counts the number times a collision is detected later than 512 bits-times into the transmission of a frame. This counter is applicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.35 | Counter32 | read-only | current |
| cm110PortOutFcsErrs OBJECT-TYPE An Egress counter that counts the number frames transmitted with an invalid FCS. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.36 | Counter32 | read-only | current |
| cm110PortResetCounters OBJECT-TYPE Allows the resetting of all cm110RateConvStats statistical counters for this port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.4.1.37 | YesNoValue | read-write | current |
| cm110RateConvVctTable OBJECT-TYPE Table of CM-110 type media converter module's | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5 | not-accessible | current | |
| cm110RateConvVctEntry OBJECT-TYPE Entries of the table, each relating to a separate fiber or copper port on the CM-110 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1 | not-accessible | current | |
| cm110VctSlotIndex OBJECT-TYPE The Slot number the CM-1110 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.2 | SlotNumber | not-accessible | current |
| cm110VctStart OBJECT-TYPE Set this self-clearing variable to yes initiate the Advanced Virtual Cable Test. Note: During the test, no network data will be passed. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.3 | YesNoValue | read-write | current |
| cm110VctStatus OBJECT-TYPE This object identifies the stat of the Advanced Virtual Cable Test. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.4 | INTEGER {notStarted(0), inProgress(1), testComplete(2)} | read-only | current |
| cm110VctTxPairResults OBJECT-TYPE Test result code returned from Virtual Cable Test of the Tx pair. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.5 | INTEGER {normal(0), shortDetected(1), openDetected(2), testFailed(3)} | read-only | current |
| cm110VctTxPairAmplitude OBJECT-TYPE Amplitude of Tx pair in Volts. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.6 | DisplayString (SIZE(0..20)) | read-only | current |
| cm110VctTxPairDistance OBJECT-TYPE Distance in meters to fault when test result codes is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.7 | DisplayString (SIZE(0..20)) | read-only | current |
| cm110VctRxPairResults OBJECT-TYPE Test result code returned from Virtual Cable Test of the Rx pair. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.8 | INTEGER {normal(0), shortDetected(1), openDetected(2), testFailed(3)} | read-only | current |
| cm110VctRxPairAmplitude OBJECT-TYPE Amplitude of Rx pair in Volts. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.9 | DisplayString (SIZE(0..20)) | read-only | current |
| cm110VctRxPairDistance OBJECT-TYPE Distance in meters to fault when test result codes is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.4.5.1.10 | DisplayString (SIZE(0..20)) | read-only | current |
| mcrMgt OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5 | |||
| mcrMgtTable OBJECT-TYPE Table of MCR-MGT management module status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1 | not-accessible | current | |
| mcrMgtEntry OBJECT-TYPE Entries of the table, each relating to a separate MCR-MGT type management module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1 | not-accessible | current | |
| mcrMgtSlotIndex OBJECT-TYPE The Slot number the MCR-MGT module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.2 | SlotNumber | not-accessible | current |
| mcrMgtModelName OBJECT-TYPE This object identifies the model name of management module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.3 | DisplayString | read-only | current |
| mcrMgtModelDesc OBJECT-TYPE This object identifies a static description of the management module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.4 | DisplayString | read-only | current |
| mcrMgtFailSafeBootLoaderVer OBJECT-TYPE This object identifies the fail-safe bootloader version of the management module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.5 | DisplayString | read-only | current |
| mcrMgtUpTime OBJECT-TYPE This object identifies the time (in hundredths of a second) since the management module was last re-initialized. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.6 | TimeTicks | read-only | current |
| mcrMgtConsoleDSR OBJECT-TYPE This object identifies the current status of the DSR signal, (active or inactive) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.1.1.7 | OnOffValue | read-only | current |
| mcrMgtConfigTable OBJECT-TYPE Table of MCR-MGT management module Hardware configuration type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2 | not-accessible | current | |
| mcrMgtConfigEntry OBJECT-TYPE Entries of the table, each relating to a separate MCR-MGT type management module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1 | not-accessible | current | |
| mcrMgtConfigSlotIndex OBJECT-TYPE The Slot number the MCR-MGT module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.2 | SlotNumber | not-accessible | current |
| mcrMgtConfigStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.3 | ContainerStatus | read-write | current |
| mcrMgtConfigEthSpeedDuplex OBJECT-TYPE Define the Ethernet connection speed/duplex of the twisted pair interface. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.4 | INTEGER {auto(0), speed10Half(1), speed10Full(2), speed100Half(3), speed100Full(4), speed1000(7)} | read-write | current |
| mcrMgtConfigEthCrossover OBJECT-TYPE Define the Ethernet connection crossover TX/RX Pair orientation of the twisted pair interface as auto(0), mdi(1) (straight through) or mdix(2) (crossed over). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.5 | INTEGER {auto(0), mdi(1), mdix(2)} | read-write | current |
| mcrMgtConfigConsolePortEnabled OBJECT-TYPE Determines whether the management module's console port is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.6 | YesNoValue | read-write | current |
| mcrMgtConfigConsoleSpeed OBJECT-TYPE Specifies the baud rate of the console port; keep in mind that speed is affected by the length of the cable. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.7 | INTEGER {b9600(13), b19200(14), b38400(15), b57600(16), b115200(17)} | read-write | current |
| mcrMgtConfigConsoleDataBits OBJECT-TYPE Specifies the number of bits in a byte. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.8 | INTEGER {d7(2), d8(3)} | read-write | current |
| mcrMgtConfigConsoleParity OBJECT-TYPE Specifies if you are using Even, Odd, or No parity on the console. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.9 | INTEGER {none(0), odd(1), even(2)} | read-write | current |
| mcrMgtConfigConsoleStopBits OBJECT-TYPE Specifies the number of stop bits that follow a byte. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.10 | INTEGER {s1(0), s2(1)} | read-write | current |
| mcrMgtConfigConsoleFlowControl OBJECT-TYPE Defines whether the data flow is handled by the software (Soft), hardware (Hard), both or None. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.11 | INTEGER {none(0), soft(1), hard(2), both(3)} | read-write | current |
| mcrMgtConfigConsoleMonitorDSR OBJECT-TYPE Specifies whether the RS-232 signal DSR (Data Set Ready) should be monitored, for the console port. When DSR is monitored and the management module detects the DSR signal go inactive then the current console management session will be reset. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.2.1.12 | OnOffValue | read-write | current |
| mcrMgtLedTable OBJECT-TYPE Table of MCR-MGT management module LED information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3 | not-accessible | current | |
| mcrMgtLedEntry OBJECT-TYPE Entries of the table, each relating to a separate MCR-MGT type management module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1 | not-accessible | current | |
| mcrMgtLedSlotIndex OBJECT-TYPE The Slot number the MCR-MGT module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1.2 | SlotNumber | not-accessible | current |
| mcrMgtLedPWR OBJECT-TYPE This object identifies the status of the power (PWR) LED on the management module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1.3 | INTEGER {off(0), onGreen(1)} | read-only | current |
| mcrMgtLedALM OBJECT-TYPE This object identifies the status of the alarm (ALM) LED on the management module. Possible status values are: offNoAlarms(0) - Normal operating condition onRedAlarmsPresent(1) - System hardware or software alarms present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1.4 | INTEGER {offNoAlarms(0), onRedAlarmsPresent(1)} | read-only | current |
| mcrMgtLedLKC OBJECT-TYPE This object identifies the status of the link copper (LKC) LED on the management module. Possible status values are: offLinkDown(0) - Copper link status is DOWN onGreenLinkUp(1) - Copper link status is UP | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1.5 | INTEGER {offLinkDown(0), onGreenLinkUp(1)} | read-only | current |
| mcrMgtLedCopperSpeed OBJECT-TYPE This object identifies the status of the link copper speed (100/1000) LED on the management module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.3.1.6 | INTEGER {off10Mbps(0), onYellow100Mbps(1), onGreen1000Mbps(2)} | read-only | current |
| mcrMgtEthStatsTable OBJECT-TYPE Table of MCR-MGT management module Ethernet status and statistics information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4 | not-accessible | current | |
| mcrMgtEthStatsEntry OBJECT-TYPE An entry in the Ethernet statistics table, each relating to an Ethernet interface. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1 | not-accessible | current | |
| mgtEthSlotIndex OBJECT-TYPE The Slot number the MCR-MGT module is currently inserted. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.2 | SlotNumber | not-accessible | current |
| mgtEthStatsIfIndex OBJECT-TYPE The Ethernet interface number. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.3 | GenericTableIndex | not-accessible | current |
| mgtEthStatsName OBJECT-TYPE Displays Ethernet interface name. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.4 | DisplayString | read-only | current |
| mgtEthStatsMacAddress OBJECT-TYPE Displays the MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.5 | MacAddress | read-only | current |
| mgtEthStatsStatus OBJECT-TYPE Displays the Ethernet link status - down(0) or up(1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.6 | INTEGER {down(0), up(1)} | read-only | current |
| mgtEthStatsSpeedDuplex OBJECT-TYPE Current status of the Ethernet connection speed/duplex twisted pair interface. When the management module does not know the pair speed/duplex, this variable has the value unknown(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.7 | INTEGER {unknown(0), speed10Half(1), speed10Full(2), speed100Half(3), speed100Full(4), speed1000Half(5), speed1000Full(6)} | read-only | current |
| mgtEthStatsBroadcast OBJECT-TYPE The management module's Ethernet Broadcast Flags status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.8 | YesNoValue | read-only | current |
| mgtEthStatsDebug OBJECT-TYPE The management module's Ethernet Debug Flags status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.9 | YesNoValue | read-only | current |
| mgtEthStatsLoopback OBJECT-TYPE The management module's Ethernet Loopback Flags status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.10 | YesNoValue | read-only | current |
| mgtEthStatsPointtoPoint OBJECT-TYPE The management module's Ethernet Point to Point Flags status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.11 | YesNoValue | read-only | current |
| mgtEthStatsNoTrailers OBJECT-TYPE The management module's Ethernet No Trailers Flags status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.12 | YesNoValue | read-only | current |
| mgtEthStatsRunning OBJECT-TYPE The management module's Ethernet Running Flags status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.13 | YesNoValue | read-only | current |
| mgtEthStatsNoArp OBJECT-TYPE The management module's Ethernet No Arp Protocol Flags status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.14 | YesNoValue | read-only | current |
| mgtEthStatsPromiscuous OBJECT-TYPE The management module's Ethernet Promiscuous Flags status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.15 | YesNoValue | read-only | current |
| mgtEthStatsRxMulticast OBJECT-TYPE The management module's Ethernet Receive all Multicast Flags status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.16 | YesNoValue | read-only | current |
| mgtEthStatsMasterLoadBalancer OBJECT-TYPE The management module's Ethernet Master Load Balancer Flags status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.17 | YesNoValue | read-only | current |
| mgtEthStatsSlaveLoadBalancer OBJECT-TYPE The management module's Ethernet Slave Load Balancer Flags status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.18 | YesNoValue | read-only | current |
| mgtEthStatsMulticast OBJECT-TYPE The management module's Ethernet Multicast Flags status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.19 | YesNoValue | read-only | current |
| mgtEthStatsSetMedia OBJECT-TYPE The management module's Ethernet Set Media Flags status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.20 | YesNoValue | read-only | current |
| mgtEthStatsAutoMedia OBJECT-TYPE The management module's Ethernet Auto Media Flags status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.21 | YesNoValue | read-only | current |
| mgtEthStatsDynamic OBJECT-TYPE The management module's Ethernet Dynamic Flags status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.22 | YesNoValue | read-only | current |
| mgtEthStatsLocalAddress OBJECT-TYPE The management module's Ethernet local IPv4 address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.23 | IpAddress | read-only | current |
| mgtEthStatsSubnetMask OBJECT-TYPE The management module's Ethernet IPv4 subnet mask. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.24 | IpAddress | read-only | current |
| mgtEthStatsBroadcastAddress OBJECT-TYPE The management module's Ethernet Broadcast address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.25 | IpAddress | read-only | current |
| mgtEthStatsMtu OBJECT-TYPE The management module's Ethernet MTU. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.26 | Unsigned32 | read-only | current |
| mgtEthStatsTxQLen OBJECT-TYPE The management module's Ethernet TX Queue Length. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.27 | Unsigned32 | read-only | current |
| mgtEthStatsRxBytes OBJECT-TYPE The management module's Ethernet RX Bytes count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.28 | Counter32 | read-only | current |
| mgtEthStatsTxBytes OBJECT-TYPE The management module's Ethernet TX Bytes count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.29 | Counter32 | read-only | current |
| mgtEthStatsRxPackets OBJECT-TYPE The management module's Ethernet RX Packets count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.30 | Counter32 | read-only | current |
| mgtEthStatsTxPackets OBJECT-TYPE The management module's Ethernet TX Packets count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.31 | Counter32 | read-only | current |
| mgtEthStatsRxErrors OBJECT-TYPE The management module's Ethernet RX Packets Errors count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.32 | Counter32 | read-only | current |
| mgtEthStatsTxPktErrors OBJECT-TYPE The management module's Ethernet TX Packets Errors count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.33 | Counter32 | read-only | current |
| mgtEthStatsRxDroppedPkts OBJECT-TYPE The management module's Ethernet RX Dropped packets count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.34 | Counter32 | read-only | current |
| mgtEthStatsTxDroppedPkts OBJECT-TYPE The management module's Ethernet TX Dropped packets count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.35 | Counter32 | read-only | current |
| mgtEthStatsRxOverruns OBJECT-TYPE The management module's Ethernet RX Overruns count | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.36 | Counter32 | read-only | current |
| mgtEthStatsTxOverruns OBJECT-TYPE The management module's Ethernet TX Overruns count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.37 | Counter32 | read-only | current |
| mgtEthStatsRxFrameErrs OBJECT-TYPE The management module's Ethernet RX Frame Errors count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.38 | Counter32 | read-only | current |
| mgtEthStatsTxCarrierErrs OBJECT-TYPE The management module's Ethernet TX Carrier Errors count | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.39 | Counter32 | read-only | current |
| mgtEthStatsCollisions OBJECT-TYPE The management module's Ethernet Collisions count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.5.4.1.40 | Counter32 | read-only | current |
| cm1000mmFixed OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6 | |||
| cm1000mmFixedTable OBJECT-TYPE Table of CM-1000MM type media converter module's status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1 | not-accessible | current | |
| cm1000mmFixedEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-1000MM type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1 | not-accessible | current | |
| cm1000mmSlotIndex OBJECT-TYPE The Slot number the CM-1000MM type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.2 | SlotNumber | not-accessible | current |
| cm1000mmModelname OBJECT-TYPE This object identifies the model of media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.3 | DisplayString | read-only | current |
| cm1000mmModelDesc OBJECT-TYPE This object identifies a static description of the media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.4 | DisplayString | read-only | current |
| cm1000mmHwJmp5ConfigMode OBJECT-TYPE This object identifies the media converter module's ConfigMode, set by hardware jumper J5 on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media converter module's hardware switches or jumpers. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.5 | INTEGER {hardwareSwitches(0), auto(1)} | read-only | current |
| cm1000mmHwSw1FiberAutoNeg OBJECT-TYPE Media converter module's current switch setting for fiber Auto-Negotiation. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.6 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| cm1000mmHwSw2LinkMode OBJECT-TYPE Media converter module's current switch setting for Link Mode. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.7 | INTEGER {swDownSmartLinkPassthrough(0), swUpStandard(1)} | read-only | current |
| cm1000mmHwSw3FiberFaultAlert OBJECT-TYPE Media converter module's current switch setting for Fiber Fault Alert. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.8 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| cm1000mmHwSw4Loopback1 OBJECT-TYPE Media converter module's current switch setting for loopback (fiber port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.9 | INTEGER {swDownEnabled(0), swUpDisabled(1)} | read-only | current |
| cm1000mmHwSw5Loopback2 OBJECT-TYPE Media converter module's current switch setting for loopback (fiber port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.10 | INTEGER {swDownEnabled(0), swUpDisabled(1)} | read-only | current |
| cm1000mmFiber1LinkStatus OBJECT-TYPE Media converter module's current fiber link status (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.12 | INTEGER {down(0), up(1)} | read-only | current |
| cm1000mmFiber1ConnType OBJECT-TYPE Media converter module's fiber port connector type (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.13 | INTEGER {sc(0), lc(1), st(2), sfp(3), fc(5), mtrj(6)} | read-only | current |
| cm1000mmFiber1AutoNegState OBJECT-TYPE Media converter module's current fiber auto-negotiation state (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.14 | INTEGER {disabled(0), complete(1), inProgress(2)} | read-only | current |
| cm1000mmFiber1Speed OBJECT-TYPE Media converter module's fiber port speed in megabits per second (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.15 | INTEGER {speed1000Mbps(2)} | read-only | current |
| cm1000mmFiber1Duplex OBJECT-TYPE If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.16 | INTEGER {half(0), full(1)} | read-only | current |
| cm1000mmFiber1PauseEnh OBJECT-TYPE If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.17 | INTEGER {disabled(0), symmetrical(1), asymmetricalTx(2), asymmetricalRx(3)} | read-only | current |
| cm1000mmFiber1LPRFStatus OBJECT-TYPE Media converter module's fiber Link Partner Remote Fault status (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.18 | INTEGER {ok(0), offline(1), linkFault(2), autoNegError(3)} | read-only | current |
| cm1000mmFiber1ReceiveStatus OBJECT-TYPE This object identifies the status of whether light is being received on the fiber port (port 1) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.19 | INTEGER {fault(0), ok(1)} | read-write | current |
| cm1000mmFiber2LinkStatus OBJECT-TYPE Media converter module's current fiber link status (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.20 | INTEGER {down(0), up(1)} | read-only | current |
| cm1000mmFiber2ConnType OBJECT-TYPE Media converter module's fiber port connector type (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.21 | INTEGER {sc(0), lc(1), st(2), sfp(3), fc(5), mtrj(6)} | read-only | current |
| cm1000mmFiber2AutoNegState OBJECT-TYPE Media converter module's current fiber auto-negotiation state (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.22 | INTEGER {disabled(0), complete(1), inProgress(2)} | read-only | current |
| cm1000mmFiber2Speed OBJECT-TYPE Media converter module's fiber port speed in megabits per second (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.23 | INTEGER {speed1000Mbps(2)} | read-only | current |
| cm1000mmFiber2Duplex OBJECT-TYPE If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.24 | INTEGER {half(0), full(1)} | read-only | current |
| cm1000mmFiber2PauseEnh OBJECT-TYPE If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.25 | INTEGER {disabled(0), symmetrical(1), asymmetricalTx(2), asymmetricalRx(3)} | read-only | current |
| cm1000mmFiber2LPRFStatus OBJECT-TYPE Media converter module's fiber Link Partner Remote Fault status (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.26 | INTEGER {ok(0), offline(1), linkFault(2), autoNegError(3)} | read-only | current |
| cm1000mmFiber2ReceiveStatus OBJECT-TYPE This object identifies the status of whether light is being received on the fiber port (port 2) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.27 | INTEGER {fault(0), ok(1)} | read-write | current |
| cm1000mmFiberLoopBack OBJECT-TYPE Media converter module's current fiber loopback mode setting. Writing to this object will change the current settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.1.1.28 | INTEGER {disabled(0), port1(1), port2(2)} | read-write | current |
| cm1000mmConfigTable OBJECT-TYPE Table of CM-1000MM type media converter module's configuration type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2 | not-accessible | current | |
| cm1000mmConfigEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-1000MM type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1 | not-accessible | current | |
| cm1000mmConfigSlotIndex OBJECT-TYPE The Slot number the CM-1000MM type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.2 | SlotNumber | not-accessible | current |
| cm1000mmConfigStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.3 | ContainerStatus | read-write | current |
| cm1000mmConfigModuleName OBJECT-TYPE This object identifies a user configurable name for the media converter module present in the chassis. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.4 | DisplayString (SIZE(0..63)) | read-write | current |
| cm1000mmConfigLinkMode OBJECT-TYPE This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.5 | INTEGER {standard(0), smartLinkPassthrough(1)} | read-write | current |
| cm1000mmConfigFiberFaultAlert OBJECT-TYPE This object identifies the Fiber Fault Alert setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.6 | EnableDisableValue | read-write | current |
| cm1000mmConfigJumboPackets OBJECT-TYPE This object identifies the Jumbo Packet setting for the media converter module present in the chassis. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.7 | EnableDisableValue | read-write | current |
| cm1000mmConfigFiberAutoNeg OBJECT-TYPE This object identifies the wither fiber auto-negotiation is enabled for both ports. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.8 | EnableDisableValue | read-write | current |
| cm1000mmConfigFiber1PortName OBJECT-TYPE This object identifies a user definable name for the fiber port (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.9 | DisplayString (SIZE(0..8)) | read-write | current |
| cm1000mmConfigFiber1PortEnable OBJECT-TYPE This object identifies whether the fiber port is enabled (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.10 | YesNoValue | read-write | current |
| cm1000mmConfigFiber2PortName OBJECT-TYPE This object identifies a user definable name for the fiber port (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.11 | DisplayString (SIZE(0..8)) | read-write | current |
| cm1000mmConfigFiber2PortEnable OBJECT-TYPE This object identifies whether the fiber port is enabled (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.2.1.12 | YesNoValue | read-write | current |
| cm1000mmLedTable OBJECT-TYPE Table of CM-1000MM type media converter module's LED status information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3 | not-accessible | current | |
| cm1000mmLedEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-1000MM type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3.1 | not-accessible | current | |
| cm1000mmLedsSlotIndex OBJECT-TYPE The Slot number the CM-1000 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3.1.2 | SlotNumber | not-accessible | current |
| cm1000mmLedPWR OBJECT-TYPE This object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Fiber loopback enabled | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3.1.3 | INTEGER {off(0), onGreen(1), blinking(2)} | read-only | current |
| cm1000mmLedLK1 OBJECT-TYPE This object identifies the status of the link fiber port 1 (LK1) LED on the media converter module. Possible status values are: off(0) - No fiber link on(1) - Fiber link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3.1.4 | INTEGER {off(0), on(1)} | read-only | current |
| cm1000mmLedLK2 OBJECT-TYPE This object identifies the status of the link fiber port 2 (LK2) LED on the media converter module. Possible status values are: off(0) - No fiber link on(1) - Fiber link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.6.3.1.5 | INTEGER {off(0), on(1)} | read-only | current |
| cm100mmFixed OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7 | |||
| cm100mmFixedTable OBJECT-TYPE Table of CM-100MM type media converter module's configuration and status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1 | not-accessible | current | |
| cm100mmFixedEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-100MM type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1 | not-accessible | current | |
| cm100mmSlotIndex OBJECT-TYPE The Slot number the CM-100MM type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.2 | SlotNumber | not-accessible | current |
| cm100mmModelName OBJECT-TYPE This object identifies the model of media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.3 | DisplayString | read-only | current |
| cm100mmModelDesc OBJECT-TYPE This object identifies a static description of the media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.4 | DisplayString | read-only | current |
| cm100mmHwJmp5ConfigMode OBJECT-TYPE This object identifies the media converter module's ConfigMode, set by hardware switch on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media module's hardware switches or jumpers. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.5 | INTEGER {hardwareSwitches(0), auto(1)} | read-only | current |
| cm100mmHwSw1LinkPassthrough OBJECT-TYPE Media converter module's current switch setting for Link Passthrough. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.6 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| cm100mmHwSw2FarEndFault OBJECT-TYPE Media converter module's current switch setting for Far-End Fault. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.7 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| cm100mmHwSw3Loopback1 OBJECT-TYPE Media converter module's current switch setting for Loopback (fiber port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.8 | INTEGER {swDownEnabled(0), swUpDisabled(1)} | read-only | current |
| cm100mmHwSw4Loopback2 OBJECT-TYPE Media converter module's current switch setting for Loopback (fiber port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.9 | INTEGER {swDownEnabled(0), swUpDisabled(1)} | read-only | current |
| cm100mmFiber1LinkStatus OBJECT-TYPE Media converter module's current fiber link status (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.12 | INTEGER {down(0), up(1)} | read-only | current |
| cm100mmFiber1ConnType OBJECT-TYPE Media converter module's fiber port connector type (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.13 | INTEGER {sc(0), lc(1), st(2), sfp(3), fc(5), mtrj(6)} | read-only | current |
| cm100mmFiber1Speed OBJECT-TYPE Media converter module's fiber port speed in megabits per second (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.14 | INTEGER {speed100Mbps(1)} | read-only | current |
| cm100mmFiber1FarEndFault OBJECT-TYPE Media converter module's current fiber Far End Fault status (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.15 | INTEGER {disable(0), ok(1), receivingFEF(2), sendingFEF(3)} | read-only | current |
| cm100mmFiber1ReceiveStatus OBJECT-TYPE This object identifies the status of whether light is being received on the fiber port (port 1) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.16 | INTEGER {fault(0), ok(1)} | read-write | current |
| cm100mmFiber2LinkStatus OBJECT-TYPE Media converter module's current fiber link status (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.17 | INTEGER {down(0), up(1)} | read-only | current |
| cm100mmFiber2ConnType OBJECT-TYPE Media converter module's fiber port connector type (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.18 | INTEGER {sc(0), lc(1), st(2), sfp(3), fc(5), mtrj(6)} | read-only | current |
| cm100mmFiber2Speed OBJECT-TYPE Media converter module's fiber port speed in megabits per second (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.19 | INTEGER {speed100Mbps(1)} | read-only | current |
| cm100mmFiber2FarEndFault OBJECT-TYPE Media converter module's current fiber Far End Fault status (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.20 | INTEGER {disable(0), ok(1), receivingFEF(2), sendingFEF(3)} | read-only | current |
| cm100mmFiber2ReceiveStatus OBJECT-TYPE This object identifies the status of whether light is being received on the fiber port (port 2) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.21 | INTEGER {fault(0), ok(1)} | read-write | current |
| cm100mmFiberLoopBack OBJECT-TYPE This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.1.1.22 | INTEGER {disabled(0), port1(1), port2(2)} | read-write | current |
| cm100mmConfigTable OBJECT-TYPE Table of CM-100MM type media converter module's configuration and status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2 | not-accessible | current | |
| cm100mmConfigEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-100MM type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1 | not-accessible | current | |
| cm100mmConfigSlotIndex OBJECT-TYPE The Slot number the CM-100MM type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.2 | SlotNumber | not-accessible | current |
| cm100mmConfigStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.3 | ContainerStatus | read-write | current |
| cm100mmConfigModuleName OBJECT-TYPE This object identifies a user configurable name for the media converter module present in the chassis. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.4 | DisplayString (SIZE(0..63)) | read-write | current |
| cm100mmConfigLinkMode OBJECT-TYPE This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.5 | INTEGER {standard(0), linkPassthrough(1)} | read-write | current |
| cm100mmConfigFiberFarEndFault OBJECT-TYPE This object identifies the fiber Far End Fault setting for the media module. This setting is always enabled if Link Mode is set to linkPassthrough. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.6 | EnableDisableValue | read-write | current |
| cm100mmConfigFiber1PortName OBJECT-TYPE This object identifies a user definable name for the fiber port (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.7 | DisplayString (SIZE(0..8)) | read-write | current |
| cm100mmConfigFiber1PortEnable OBJECT-TYPE This object identifies whether the fiber port is enabled (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.8 | YesNoValue | read-write | current |
| cm100mmConfigFiber2PortName OBJECT-TYPE This object identifies a user definable name for the fiber port (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.9 | DisplayString (SIZE(0..8)) | read-write | current |
| cm100mmConfigFiber2PortEnable OBJECT-TYPE This object identifies whether the fiber port is enabled (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.2.1.10 | YesNoValue | read-write | current |
| cm100mmLedTable OBJECT-TYPE Table of CM-100MM type media converter module's LED status information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3 | not-accessible | current | |
| cm100mmLedEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-100MM type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3.1 | not-accessible | current | |
| cm100mmLedSlotIndex OBJECT-TYPE The Slot number the CM-100MM type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3.1.2 | SlotNumber | not-accessible | current |
| cm100mmLedPWR OBJECT-TYPE This object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Fiber loopback enabled | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3.1.3 | INTEGER {off(0), onGreen(1), blinking(2)} | read-only | current |
| cm100mmLedLK1 OBJECT-TYPE This object identifies the status of the link fiber port 1 (LK1) LED on the media converter module. Possible status values are: off(0) - No fiber link on(1) - Fiber link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3.1.4 | INTEGER {off(0), on(1)} | read-only | current |
| cm100mmLedLK2 OBJECT-TYPE This object identifies the status of the link fiber port 2 (LK2) LED on the media converter module. Possible status values are: off(0) - No fiber link on(1) - Fiber link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.7.3.1.5 | INTEGER {off(0), on(1)} | read-only | current |
| cm10gFixed OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8 | |||
| cm10gFixedTable OBJECT-TYPE Table of CM-10G type media converter module's status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1 | not-accessible | current | |
| cm10gFixedEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-10G type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1 | not-accessible | current | |
| cm10gSlotIndex OBJECT-TYPE The Slot number the CM-10G type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.2 | SlotNumber | not-accessible | current |
| cm10gModelname OBJECT-TYPE This object identifies the model of media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.3 | DisplayString | read-only | current |
| cm10gModelDesc OBJECT-TYPE This object identifies a static description of the media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.4 | DisplayString | read-only | current |
| cm10gHwJmp5ConfigMode OBJECT-TYPE This object identifies the media converter module's ConfigMode, set by hardware jumper J5 on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media converter module's hardware switches or jumpers. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.5 | INTEGER {hardwareSwitches(0), auto(1)} | read-only | current |
| cm10gHwSw1OperationMode OBJECT-TYPE Media converter module's current switch setting for operation mode. Data mode is for normal data transmission. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.6 | INTEGER {test(0), data(1)} | read-only | current |
| cm10gHwSw2LinkMode OBJECT-TYPE Media converter module's current switch setting for Link Mode. If the Operation switch is set to Test, then this object indicates whether the port is in loopback or performing the build in link-test. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.7 | INTEGER {swDownSmartLinkPassthrough(0), swUpStandard(1)} | read-only | current |
| cm10gHwSw3FiberFaultAlert OBJECT-TYPE Media converter module's current switch setting for Fiber Fault Alert. If the Operation switch is set to Test, then this object indicates which port is in test mode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.8 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| cm10gHwSw4Port1EdcMode OBJECT-TYPE This oject indicates the current switch setting for EDC auto mode for port 1. This object only applies to SFP moudles. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.9 | INTEGER {disabled(0), enabled(1)} | read-only | current |
| cm10gHwSw5Port2EdcMode OBJECT-TYPE This oject indicates the current switch setting for EDC auto mode for port 2. This object only applies to SFP moudles. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.10 | INTEGER {disabled(0), enabled(1)} | read-only | current |
| cm10gPort1LinkStatus OBJECT-TYPE Media converter module's current fiber link status (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.11 | INTEGER {down(0), up(1), shutdown(2)} | read-only | current |
| cm10gPort1ConnType OBJECT-TYPE Media converter module's fiber port connector type (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.12 | INTEGER {sc(0), lc(1), st(2), sfp(3), fc(5), mtrj(6), xfp(7), sfpPlus(8)} | read-only | current |
| cm10gPort1AutoNegState OBJECT-TYPE Media converter module's current fiber auto-negotiation state (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.13 | INTEGER {disabled(0), complete(1), inProgress(2)} | read-only | current |
| cm10gPort1Speed OBJECT-TYPE Media converter module's fiber port speed in megabits per second (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.14 | INTEGER {speed10Mbps(0), speed100Mbps(1), speed1000Mbps(2), speed10Gbps(3)} | read-only | current |
| cm10gPort1Duplex OBJECT-TYPE If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.15 | INTEGER {half(0), full(1)} | read-only | current |
| cm10gPort1PauseEnh OBJECT-TYPE If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.16 | INTEGER {disabled(0), symmetrical(1), asymmetricalTx(2), asymmetricalRx(3)} | read-only | current |
| cm10gPort1ReceiveStatus OBJECT-TYPE This object identifies the status of whether light is being received on the fiber port (port 1) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.17 | INTEGER {fault(0), ok(1)} | read-only | current |
| cm10gPort2LinkStatus OBJECT-TYPE Media converter module's current fiber link status (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.18 | INTEGER {down(0), up(1), shutdown(2)} | read-only | current |
| cm10gPort2ConnType OBJECT-TYPE Media converter module's fiber port connector type (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.19 | INTEGER {sc(0), lc(1), st(2), sfp(3), fc(5), mtrj(6), xfp(7), sfpPlus(8)} | read-only | current |
| cm10gPort2AutoNegState OBJECT-TYPE Media converter module's current fiber auto-negotiation state (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.20 | INTEGER {disabled(0), complete(1), inProgress(2)} | read-only | current |
| cm10gPort2Speed OBJECT-TYPE Media converter module's fiber port speed in megabits per second (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.21 | INTEGER {speed10Mbps(0), speed100Mbps(1), speed1000Mbps(2), speed10Gbps(3)} | read-only | current |
| cm10gPort2Duplex OBJECT-TYPE If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.22 | INTEGER {half(0), full(1)} | read-only | current |
| cm10gPort2PauseEnh OBJECT-TYPE If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.23 | INTEGER {disabled(0), symmetrical(1), asymmetricalTx(2), asymmetricalRx(3)} | read-only | current |
| cm10gPort2ReceiveStatus OBJECT-TYPE This object identifies the status of whether light is being received on the fiber port (port 2) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.24 | INTEGER {fault(0), ok(1)} | read-only | current |
| cm10gPortLoopBack OBJECT-TYPE Media converter module's current port loopback mode setting. Writing to this object will change the current settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.25 | INTEGER {disabled(0), port1(1), port2(2)} | read-write | current |
| cm10gPortTestMode OBJECT-TYPE Media converter module's current port test mode setting. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.1.1.26 | INTEGER {disabled(0), port1(1), port2(2)} | read-only | current |
| cm10gConfigTable OBJECT-TYPE Table of CM-10G type media converter module's configuration type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2 | not-accessible | current | |
| cm10gConfigEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-10G type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1 | not-accessible | current | |
| cm10gConfigSlotIndex OBJECT-TYPE The Slot number the CM-10G type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.2 | SlotNumber | not-accessible | current |
| cm10gConfigStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.3 | ContainerStatus | read-write | current |
| cm10gConfigModuleName OBJECT-TYPE This object identifies a user configurable name for the media converter module present in the chassis. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.4 | DisplayString (SIZE(0..63)) | read-write | current |
| cm10gConfigLinkMode OBJECT-TYPE This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.5 | INTEGER {standard(0), smartLinkPassthrough(1)} | read-write | current |
| cm10gConfigFiberFaultAlert OBJECT-TYPE This object identifies the Fiber Fault Alert setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.6 | EnableDisableValue | read-write | current |
| cm10gConfigFiberAutoNeg OBJECT-TYPE This object identifies the wither fiber auto-negotiation is enabled for both ports. This only applies if 1G SFP modules are in use. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.7 | EnableDisableValue | read-write | current |
| cm10gConfigPort1Name OBJECT-TYPE This object identifies a user definable name for port 1. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.8 | DisplayString (SIZE(0..8)) | read-write | current |
| cm10gConfigPort1Enable OBJECT-TYPE This object identifies whether port 1 is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.9 | YesNoValue | read-write | current |
| cm10gConfigPort1EdcMode OBJECT-TYPE This object identifies the EDC mode for this port. This config option only applies for an SFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.10 | INTEGER {auto(0), alternate(1), linear(2), limiting(3), cx1(4)} | read-write | current |
| cm10gConfigPort1FecEnable OBJECT-TYPE This object identifies the whether FEC control is enabled for this port. This config option only applies for an XFP module. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.11 | YesNoValue | read-write | current |
| cm10gConfigPort1FecAmplitude OBJECT-TYPE This object identifies the FEC Amplitude value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.12 | INTEGER (-128..127) | read-write | current |
| cm10gConfigPort1FecPhase OBJECT-TYPE This object identifies the FEC phase value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.13 | INTEGER (-128..127) | read-write | current |
| cm10gConfigPort1WavelengthEnable OBJECT-TYPE This object identifies whether Wavelength fine tuning is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.14 | YesNoValue | read-write | current |
| cm10gConfigPort1WavelengthValue OBJECT-TYPE This object identifies Wavelength fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.15 | INTEGER (0..65535) | read-write | current |
| cm10gConfigPort1ChannelEnable OBJECT-TYPE This object identifies whether channel number fine tuning is enabled for this port. This config option only applies for an XFP module. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.16 | YesNoValue | read-write | current |
| cm10gConfigPort1ChannelNumber OBJECT-TYPE This object identifies the channel number fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.17 | INTEGER (1..65535) | read-write | current |
| cm10gConfigPort1TxDitherEnable OBJECT-TYPE This object identifies the whether TX Dither control is enabled on this port. If not enabled the default TX Dither value will be used. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.18 | YesNoValue | read-write | current |
| cm10gConfigPort1TxDitherValue OBJECT-TYPE This object identifies the whether TX Dither is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.19 | EnableDisableValue | read-write | current |
| cm10gConfigPort2Name OBJECT-TYPE This object identifies a user definable name for port 2. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.20 | DisplayString (SIZE(0..8)) | read-write | current |
| cm10gConfigPort2Enable OBJECT-TYPE This object identifies whether port 2 is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.21 | YesNoValue | read-write | current |
| cm10gConfigPort2EdcMode OBJECT-TYPE This object identifies the EDC mode for this port. This config option only applies for an SFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.22 | INTEGER {auto(0), alternate(1), linear(2), limiting(3), cx1(4)} | read-write | current |
| cm10gConfigPort2FecEnable OBJECT-TYPE This object identifies the whether FEC control is enabled for this port. This config option only applies for an XFP module. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.23 | YesNoValue | read-write | current |
| cm10gConfigPort2FecAmplitude OBJECT-TYPE This object identifies the FEC Amplitude value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.24 | INTEGER (-128..127) | read-write | current |
| cm10gConfigPort2FecPhase OBJECT-TYPE This object identifies the FEC phase value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.25 | INTEGER (-128..127) | read-write | current |
| cm10gConfigPort2WavelengthEnable OBJECT-TYPE This object identifies whether Wavelength fine tuning is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.26 | YesNoValue | read-write | current |
| cm10gConfigPort2WavelengthValue OBJECT-TYPE This object identifies Wavelength fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.27 | INTEGER (0..65535) | read-write | current |
| cm10gConfigPort2ChannelEnable OBJECT-TYPE This object identifies whether channel number fine tuning is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.28 | YesNoValue | read-write | current |
| cm10gConfigPort2ChannelNumber OBJECT-TYPE This object identifies the channel number fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.29 | INTEGER (1..65535) | read-write | current |
| cm10gConfigPort2TxDitherEnable OBJECT-TYPE This object identifies the whether TX Dither control is enabled on this port. If not enabled the default TX Dither value will be used. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.30 | YesNoValue | read-write | current |
| cm10gConfigPort2TxDitherValue OBJECT-TYPE This object identifies the whether TX Dither is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.2.1.31 | EnableDisableValue | read-write | current |
| cm10gLedTable OBJECT-TYPE Table of CM-10G type media converter module's LED status information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3 | not-accessible | current | |
| cm10gLedEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-10G type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3.1 | not-accessible | current | |
| cm10gLedsSlotIndex OBJECT-TYPE The Slot number the CM-10G type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3.1.2 | SlotNumber | not-accessible | current |
| cm10gLedPWR OBJECT-TYPE This object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Loopback or Link-Test enabled | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3.1.3 | INTEGER {off(0), onGreen(1), blinking(2)} | read-only | current |
| cm10gLedLK1 OBJECT-TYPE This object identifies the status of the port 1 link (LK1) LED on the media converter module. Possible status values are: off(0) - No link on(1) - Port link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3.1.4 | INTEGER {off(0), on(1)} | read-only | current |
| cm10gLedLK2 OBJECT-TYPE This object identifies the status of the port 2 link (LK2) LED on the media converter module. Possible status values are: off(0) - No link on(1) - Port link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.8.3.1.5 | INTEGER {off(0), on(1)} | read-only | current |
| exCM OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9 | |||
| exCMTable OBJECT-TYPE Table of CM-1110 type media converter module's configuration and status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1 | not-accessible | current | |
| exCMEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-1110 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1 | not-accessible | current | |
| exCMSlotIndex OBJECT-TYPE The Slot number the CM-1110 type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.2 | SlotNumber | not-accessible | current |
| exCMModelName OBJECT-TYPE This object identifies the model of media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.3 | DisplayString | read-only | current |
| exCMModelDesc OBJECT-TYPE This object identifies a static description of the media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.4 | DisplayString | read-only | current |
| exCMHwJmp5ConfigMode OBJECT-TYPE This object identifies the media converter module's ConfigMode, set by hardware switch on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media module's hardware switches or jumpers. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.5 | INTEGER {hardwareSwitches(0), auto(1)} | read-only | current |
| exCMHwSw1AutoLocalRemote OBJECT-TYPE Media converter module's current switch setting for VDSL role. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.6 | INTEGER {swDownRemote(0), swUpAutoLocal(1)} | read-only | current |
| exCMHwSw2Rate OBJECT-TYPE Media converter module's current switch setting for VDSL rate/reach. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.7 | INTEGER {swDownLongRange(0), swUpHighSpeed(1)} | read-only | current |
| exCMHwSw3SymmetricAsymmetric OBJECT-TYPE Media converter module's current switch setting for VDSL band plan. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.8 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| exCMHwSw4SnrRatio OBJECT-TYPE Media converter module's current switch setting for VDSL signal-to-noise ratio. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.9 | INTEGER {swDown6db(0), swUp9db(1)} | read-only | current |
| exCMHwSw5Loopback OBJECT-TYPE Media converter module's current switch setting for VDSL loopback. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.10 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| exCMHwSw6EthAutoNeg OBJECT-TYPE Media converter module's current switch setting for ethernet auto-negotiation. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.11 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| exCMHwSw7EthSpeed OBJECT-TYPE Media converter module's current switch setting for ethernet speed (when auto-negotiation is disabled). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.12 | INTEGER {swDown10Mbps(0), swUp100Mbps(1)} | read-only | current |
| exCMHwSw8EthDuplex OBJECT-TYPE Media converter module's current switch setting for ethernet duplex (when auto-negotiation is disabled). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.13 | INTEGER {swDownHalf(0), swUpFull(1)} | read-only | current |
| exCMHwSw9LinkMode OBJECT-TYPE Media converter module's current switch setting for link mode. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.14 | INTEGER {swDownLinkPassthrough(0), swUpStandard(1)} | read-only | current |
| exCMHwSw10InterlinkFaultFeedback OBJECT-TYPE Media converter module's current switch setting for interlink fault feedback. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.15 | INTEGER {swDownEnabled(0), swUpDisabled(1)} | read-only | current |
| exCMVdslLinkStatus OBJECT-TYPE Media converter module's current VDSL link status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.16 | INTEGER {idle(0), handshake(1), training(2), up(3), upLogicallyDown(4)} | read-only | current |
| exCMVdslConnType OBJECT-TYPE Media converter module's VDSL port connector type. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.17 | INTEGER {rj45(9), terminalBlock(10), bnc(11)} | read-only | current |
| exCMVdslLoopBack OBJECT-TYPE This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.18 | EnableDisableValue | read-write | current |
| exCMVdslRole OBJECT-TYPE This object identifies the VDSL port's current role. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.19 | INTEGER {local(0), remote(1)} | read-only | current |
| exCMVdslProfile OBJECT-TYPE This object identifies the VDSL port's current profile. This value has no meaning when the VDSL role is remote. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.20 | INTEGER {notApplicable(0), profile1-AnnexA-R-POTS-D-32-EU-32-30a(1), profile2-AnnexA-R-POTS-D-32-EU-32-17a(2), profile3-AnnexA-R-POTS-D-32-EU-32-12b(3), profile4-AnnexA-R-POTS-D-32-EU-32-12a(4), profile5-AnnexA-R-POTS-D-32-EU-32-8a(5), profile6-AnnexA-R-POTS-D-32-EU-32-8b(6), profile7-AnnexA-R-POTS-D-32-EU-32-8c(7), profile8-AnnexA-R-POTS-D-32-EU-32-8d(8), profile9-AnnexA-R-POTS-D-64-EU-64-30a-NUS0(9), profile10-AnnexA-R-POTS-D-64-EU-64-17a(10), profile11-AnnexB-B7-3-997-M1x-M(11), profile12-AnnexB-B7-4-997-M2x-M-8(12), profile13-AnnexB-B7-5-997-M2x-A(13), profile14-AnnexB-B7-6-997-M2x-M(14), profile15-AnnexB-B7-9-997E17-M2x-A(15), profile16-AnnexB-B7-10-997E30-M2x-NUS0(16), profile17-AnnexB-B8-1-998-M1x-A(17), profile18-AnnexB-B8-2-998-M1x-B(18), profile19-AnnexB-B8-4-998-M2x-A(19), profile20-AnnexB-B8-5-998-M2x-M(20), profile21-AnnexB-B8-6-998-M2x-B(21), profile22-AnnexB-B8-8-998E17-M2x-NUS0(22), profile23-AnnexB-B8-9-998E17-M2x-NUS0-M(23), profile24-AnnexB-B8-10-998ADE17-M2x-NUS0-M(24), profile25-AnnexB-B8-11-998E17-M2x-A(25), profile26-AnnexB-B8-12-998E17-M2x-B(26), profile27-AnnexB-B8-13-998E30-M2x-NUS0(27), profile28-AnnexB-B8-14-998E30-M2x-NUS0-M(28), profile29-AnnexB-B8-15-998ADE30-M2x-NUS0-M(29), profile30-AnnexB-B8-16-998ADE30-M2x-NUS0-A(30), profile31-AnnexC-POTS-25-138-b(31), profile32-AnnexC-POTS-25-276-b(32), profile33-AnnexC-TMC-ISDN(33)} | read-only | current |
| exCMVdslBitswapping OBJECT-TYPE This object identifies the VDSL port's current bitswapping status. This value has no meaning when the VDSL role is remote. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.21 | INTEGER {notApplicable(-1), off(0), on(1)} | read-only | current |
| exCMVdslStatusAttainableDataRateUp OBJECT-TYPE This object identifies the VDSL port's attainable data rate (upstream) in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.22 | Integer32 | read-only | current |
| exCMVdslStatusAttainableDataRateDown OBJECT-TYPE This object identifies the VDSL port's attainable data rate (downstream) in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.23 | Integer32 | read-only | current |
| exCMVdslStatusActualDataRateUp OBJECT-TYPE This object identifies the VDSL port's actual data rate (upstream) in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.24 | Integer32 | read-only | current |
| exCMVdslStatusActualDataRateDown OBJECT-TYPE This object identifies the VDSL port's actual data rate (downstream) in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.25 | Integer32 | read-only | current |
| exCMVdslStatusPrevDataRateUp OBJECT-TYPE This object identifies the VDSL port's previous data rate (upstream) in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.26 | Integer32 | read-only | current |
| exCMVdslStatusPrevDataRateDown OBJECT-TYPE This object identifies the VDSL port's previous data rate (downstream) in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.27 | Integer32 | read-only | current |
| exCMVdslStatusActualSnrUp OBJECT-TYPE This object identifies the VDSL port's actual signal-to-noise ratio (upstream) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.28 | Integer32 | read-only | current |
| exCMVdslStatusActualSnrDown OBJECT-TYPE This object identifies the VDSL port's actual signal-to-noise ratio (downstream) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.29 | Integer32 | read-only | current |
| exCMVdslStatusActualSnrUs0 OBJECT-TYPE This object identifies the VDSL port's actual signal-to-noise ratio (upstream 0) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.30 | Integer32 | read-only | current |
| exCMVdslStatusActualSnrUs1 OBJECT-TYPE This object identifies the VDSL port's actual signal-to-noise ratio (upstream 1) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.31 | Integer32 | read-only | current |
| exCMVdslStatusActualSnrDs1 OBJECT-TYPE This object identifies the VDSL port's actual signal-to-noise ratio (downstream 1) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.32 | Integer32 | read-only | current |
| exCMVdslStatusActualSnrUs2 OBJECT-TYPE This object identifies the VDSL port's actual signal-to-noise ratio (upstream 2) in 0.2 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.33 | Integer32 | read-only | current |
| exCMVdslStatusActualSnrDs2 OBJECT-TYPE This object identifies the VDSL port's actual signal-to-noise ratio (downstream 2) in 0.2 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.34 | Integer32 | read-only | current |
| exCMVdslStatusActualSnrUs3 OBJECT-TYPE This object identifies the VDSL port's actual signal-to-noise ratio (upstream 3) in 0.3 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.35 | Integer32 | read-only | current |
| exCMVdslStatusActualSnrDs3 OBJECT-TYPE This object identifies the VDSL port's actual signal-to-noise ratio (downstream 3) in 0.3 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.36 | Integer32 | read-only | current |
| exCMVdslStatusActualSnrUs4 OBJECT-TYPE This object identifies the VDSL port's actual signal-to-noise ratio (upstream 4) in 0.4 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.37 | Integer32 | read-only | current |
| exCMVdslStatusActualSnrDs4 OBJECT-TYPE This object identifies the VDSL port's actual signal-to-noise ratio (downstream 4) in 0.4 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.38 | Integer32 | read-only | current |
| exCMVdslStatusActualSignalAttenuationUp OBJECT-TYPE This object identifies the VDSL port's actual signal attenuation (upstream) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.39 | Integer32 | read-only | current |
| exCMVdslStatusActualSignalAttenuationDown OBJECT-TYPE This object identifies the VDSL port's actual signal attenuation (downstream) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.40 | Integer32 | read-only | current |
| exCMVdslStatusActualSignalAttenuationUs0 OBJECT-TYPE This object identifies the VDSL port's actual signal attenuation (upstream 0) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.41 | Integer32 | read-only | current |
| exCMVdslStatusActualSignalAttenuationUs1 OBJECT-TYPE This object identifies the VDSL port's actual signal attenuation (upstream 1) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.42 | Integer32 | read-only | current |
| exCMVdslStatusActualSignalAttenuationDs1 OBJECT-TYPE This object identifies the VDSL port's actual signal attenuation (downstream 1) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.43 | Integer32 | read-only | current |
| exCMVdslStatusActualSignalAttenuationUs2 OBJECT-TYPE This object identifies the VDSL port's actual signal attenuation (upstream 2) in 0.2 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.44 | Integer32 | read-only | current |
| exCMVdslStatusActualSignalAttenuationDs2 OBJECT-TYPE This object identifies the VDSL port's actual signal attenuation (downstream 2) in 0.2 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.45 | Integer32 | read-only | current |
| exCMVdslStatusActualSignalAttenuationUs3 OBJECT-TYPE This object identifies the VDSL port's actual signal attenuation (upstream 3) in 0.3 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.46 | Integer32 | read-only | current |
| exCMVdslStatusActualSignalAttenuationDs3 OBJECT-TYPE This object identifies the VDSL port's actual signal attenuation (downstream 3) in 0.3 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.47 | Integer32 | read-only | current |
| exCMVdslStatusActualSignalAttenuationUs4 OBJECT-TYPE This object identifies the VDSL port's actual signal attenuation (upstream 4) in 0.4 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.48 | Integer32 | read-only | current |
| exCMVdslStatusActualSignalAttenuationDs4 OBJECT-TYPE This object identifies the VDSL port's actual signal attenuation (downstream 4) in 0.4 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.49 | Integer32 | read-only | current |
| exCMVdslStatusActualLineAttenuationUp OBJECT-TYPE This object identifies the VDSL port's actual line attenuation (upstream) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.50 | Integer32 | read-only | current |
| exCMVdslStatusActualLineAttenuationDown OBJECT-TYPE This object identifies the VDSL port's actual line attenuation (downstream) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.51 | Integer32 | read-only | current |
| exCMVdslStatusActualLineAttenuationUs0 OBJECT-TYPE This object identifies the VDSL port's actual line attenuation (upstream 0) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.52 | Integer32 | read-only | current |
| exCMVdslStatusActualLineAttenuationUs1 OBJECT-TYPE This object identifies the VDSL port's actual line attenuation (upstream 1) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.53 | Integer32 | read-only | current |
| exCMVdslStatusActualLineAttenuationDs1 OBJECT-TYPE This object identifies the VDSL port's actual line attenuation (downstream 1) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.54 | Integer32 | read-only | current |
| exCMVdslStatusActualLineAttenuationUs2 OBJECT-TYPE This object identifies the VDSL port's actual line attenuation (upstream 2) in 0.2 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.55 | Integer32 | read-only | current |
| exCMVdslStatusActualLineAttenuationDs2 OBJECT-TYPE This object identifies the VDSL port's actual line attenuation (downstream 2) in 0.2 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.56 | Integer32 | read-only | current |
| exCMVdslStatusActualLineAttenuationUs3 OBJECT-TYPE This object identifies the VDSL port's actual line attenuation (upstream 3) in 0.3 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.57 | Integer32 | read-only | current |
| exCMVdslStatusActualLineAttenuationDs3 OBJECT-TYPE This object identifies the VDSL port's actual line attenuation (downstream 3) in 0.3 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.58 | Integer32 | read-only | current |
| exCMVdslStatusActualLineAttenuationUs4 OBJECT-TYPE This object identifies the VDSL port's actual line attenuation (upstream 4) in 0.4 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.59 | Integer32 | read-only | current |
| exCMVdslStatusActualLineAttenuationDs4 OBJECT-TYPE This object identifies the VDSL port's actual line attenuation (downstream 4) in 0.4 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.60 | Integer32 | read-only | current |
| exCMVdslStatusActualInterleaveDelayUp OBJECT-TYPE This object identifies the VDSL port's actual interleave delay (upstream) in ms. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.61 | Integer32 | read-only | current |
| exCMVdslStatusActualInterleaveDelayDown OBJECT-TYPE This object identifies the VDSL port's actual interleave delay (downstream) in ms. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.62 | Integer32 | read-only | current |
| exCMVdslStatusActualInpUp OBJECT-TYPE This object identifies the VDSL port's actual INP (impulse noise protection) (upstream). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.63 | Integer32 | read-only | current |
| exCMVdslStatusActualInpDown OBJECT-TYPE This object identifies the VDSL port's actual INP (impulse noise protection) (downstream) in ms. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.64 | Integer32 | read-only | current |
| exCMVdslStatusActualInterleavingDepthUp OBJECT-TYPE This object identifies the VDSL port's actual interleaving depth (upstream). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.65 | Integer32 | read-only | current |
| exCMVdslStatusActualInterleavingDepthDown OBJECT-TYPE This object identifies the VDSL port's actual interleaving depth (impulse noise protection) (downstream) in ms. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.66 | Integer32 | read-only | current |
| exCMVdslStatusActualInterleavingBlockUp OBJECT-TYPE This object identifies the VDSL port's actual interleaving block (upstream). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.67 | Integer32 | read-only | current |
| exCMVdslStatusActualInterleavingBlockDown OBJECT-TYPE This object identifies the VDSL port's actual interleaving block (impulse noise protection) (downstream) in ms. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.68 | Integer32 | read-only | current |
| exCMVdslStatusActualTransmitPowerUp OBJECT-TYPE This object identifies the VDSL port's actual transmit power (upstream) in 0.1 dBm. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.69 | Integer32 | read-only | current |
| exCMVdslStatusActualTransmitPowerDown OBJECT-TYPE This object identifies the VDSL port's actual transmit power (downstream) in 0.1 dBm. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.70 | Integer32 | read-only | current |
| exCMVdslStatusMaxDataRateUp OBJECT-TYPE This object identifies the VDSL port's maximum data rate (upstream) in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.71 | Integer32 | read-only | current |
| exCMVdslStatusMaxDataRateDown OBJECT-TYPE This object identifies the VDSL port's maximum data rate (downstream) in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.72 | Integer32 | read-only | current |
| exCMVdslStatusMinDataRateUp OBJECT-TYPE This object identifies the VDSL port's minimum data rate (upstream) in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.73 | Integer32 | read-only | current |
| exCMVdslStatusMinDataRateDown OBJECT-TYPE This object identifies the VDSL port's minimum data rate (downstream) in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.74 | Integer32 | read-only | current |
| exCMVdslStatusTargetSnrUp OBJECT-TYPE This object identifies the VDSL port's target signal-to-noise ratio (upstream) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.75 | Integer32 | read-only | current |
| exCMVdslStatusTargetSnrDown OBJECT-TYPE This object identifies the VDSL port's target signal-to-noise ratio (downstream) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.76 | Integer32 | read-only | current |
| exCMVdslStatusMaxInterleaveDelayUp OBJECT-TYPE This object identifies the VDSL port's maximum interleave delay (upstream) in ms. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.77 | Integer32 | read-only | current |
| exCMVdslStatusMaxInterleaveDelayDown OBJECT-TYPE This object identifies the VDSL port's maximum interleave delay (downstream) in ms. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.78 | Integer32 | read-only | current |
| exCMVdslStatusMinInpUp OBJECT-TYPE This object identifies the VDSL port's minimum INP (impulse noise protection) (upstream). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.79 | Integer32 | read-only | current |
| exCMVdslStatusMinInpDown OBJECT-TYPE This object identifies the VDSL port's minimum INP (impulse noise protection) (downstream) in ms. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.80 | Integer32 | read-only | current |
| exCMVdslRemoteLoopback OBJECT-TYPE Write remoteLoopbackOff(1) or remoteLoopbackOn(2) to this object to set the loopback state of the remote VDSL peer. This object's value represents the last loopback command sent to the peer. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.81 | INTEGER {none(0), remoteLoopbackOff(1), remoteLoopbackOn(2)} | read-write | current |
| exCMVdslRemoteReset OBJECT-TYPE Write resetRemotePeer(1) to this object to reset the remote VDSL peer. This object's value has no meaning | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.82 | INTEGER {notApplicable(0), resetRemotePeer(1)} | read-write | current |
| exCMEthernetLinkStatus OBJECT-TYPE Media converter module's current Ethernet link status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.83 | INTEGER {down(0), up(1)} | read-only | current |
| exCMEthernetConnType OBJECT-TYPE Media converter module's Ethernet connector type. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.84 | INTEGER {rj45(0)} | read-only | current |
| exCMEthernetAutoNegState OBJECT-TYPE Media converter module's current Ethernet auto-negotiation state. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.85 | INTEGER {disabled(0), complete(1), inProgress(2)} | read-only | current |
| exCMEthernetSpeed OBJECT-TYPE If Ethernet auto-negotiation state is complete then this object indicates the media converter module's current Ethernet auto-negotiated speed setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.86 | INTEGER {speed10Mbs(0), speed100Mbps(1), speed1000Mbps(2)} | read-only | current |
| exCMEthernetDuplex OBJECT-TYPE If Ethernet auto-negotiation state is complete then this object indicates the media converter module's current Ethernet auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.87 | INTEGER {half(0), full(1)} | read-only | current |
| exCMEthernetCrossOver OBJECT-TYPE If Ethernet auto-negotiation state is complete then this object indicates the media converter module's current Ethernet auto-negotiated MDI/MDI-X setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.88 | INTEGER {mdi(0), mdix(1)} | read-only | current |
| exCMEthernetPauseEnh OBJECT-TYPE If Ethernet auto-negotiation state is complete then this object indicates the media converter module's current Ethernet auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.89 | INTEGER {disabled(0), symmetrical(1), asymmetricalTx(2), asymmetricalRx(3)} | read-only | current |
| exCMEthernetLPRFStatus OBJECT-TYPE Media converter module's Ethernet Link Partner Remote Fault status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.90 | INTEGER {ok(0), remoteFault(1)} | read-only | current |
| exCMEthernetAutoSpeedDownshift OBJECT-TYPE This object identifies the status of the Ethernet auto speed downshift feature. noDownshift indicates that an automatic downshift of the Ethernet speed has not occurred. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.91 | INTEGER {noDownshift(0), downshift(1)} | read-only | current |
| exCMEthernetMDI OBJECT-TYPE This object identifies the Ethernet port's crossover status: MDI or MDI-X. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.92 | INTEGER {mdi(0), mdix(1)} | read-only | current |
| exCMVdslFirmwareVersion OBJECT-TYPE This object identifies the version of the VDSL firmware. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.93 | DisplayString | read-only | current |
| exCMVdslFirmwareDate OBJECT-TYPE This object identifies the date of the VDSL firmware | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.94 | DateAndTime | read-only | current |
| exCMVdslFirmwareDateString OBJECT-TYPE This object identifies the version of the VDSL firmware, in human-readable format. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.1.1.95 | DisplayString | read-only | current |
| exCMConfigTable OBJECT-TYPE Table of CM-1110 type media converter module's configuration type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2 | not-accessible | current | |
| exCMConfigEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-1110 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1 | not-accessible | current | |
| exCMConfigSlotIndex OBJECT-TYPE The Slot number the ex-CM type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.2 | SlotNumber | not-accessible | current |
| exCMConfigStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.3 | ContainerStatus | read-write | current |
| exCMConfigModuleName OBJECT-TYPE This object identifies a user configurable name for the media converter module present in the chassis. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.4 | DisplayString (SIZE(0..63)) | read-write | current |
| exCMConfigLinkMode OBJECT-TYPE This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.5 | INTEGER {standard(0), smartLinkPassthrough(1)} | read-write | current |
| exCMConfigInterlinkFaultFeedback OBJECT-TYPE This object identifies the interlink fault feedback setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.6 | EnableDisableValue | read-write | current |
| exCMConfigVdslPortName OBJECT-TYPE This object identifies a user definable name for the VDSL port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.7 | DisplayString (SIZE(0..8)) | read-write | current |
| exCMConfigVdslPortEnable OBJECT-TYPE This object identifies whether the VDSL port is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.8 | YesNoValue | read-write | current |
| exCMConfigVdslProfileMode OBJECT-TYPE This object specifies how the VDSL profile is selected. Auto: select through exCMConfigVdslRate and exCMConfigVdslSymmetry Manual: select through exCMConfigVdslProfile. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.9 | INTEGER {auto(0), manual(1)} | read-write | current |
| exCMConfigVdslRole OBJECT-TYPE This object specifies the VDSL role: auto, local (CO), or remote (CPE). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.10 | INTEGER {auto(0), local(1), remote(2)} | read-write | current |
| exCMConfigVdslRate OBJECT-TYPE This object specifies the VDSL rate/reach. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.11 | INTEGER {highSpeed(0), longRange(1)} | read-write | current |
| exCMConfigVdslSymmetry OBJECT-TYPE This object specifies the VDSL band plan or symmetry. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.12 | INTEGER {asymmetric(0), symmetric(1)} | read-write | current |
| exCMConfigVdslProfile OBJECT-TYPE This object specifies the VDSL profile. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.13 | INTEGER {profile1-AnnexA-R-POTS-D-32-EU-32-30a(1), profile2-AnnexA-R-POTS-D-32-EU-32-17a(2), profile3-AnnexA-R-POTS-D-32-EU-32-12b(3), profile4-AnnexA-R-POTS-D-32-EU-32-12a(4), profile5-AnnexA-R-POTS-D-32-EU-32-8a(5), profile6-AnnexA-R-POTS-D-32-EU-32-8b(6), profile7-AnnexA-R-POTS-D-32-EU-32-8c(7), profile8-AnnexA-R-POTS-D-32-EU-32-8d(8), profile9-AnnexA-R-POTS-D-64-EU-64-30a-NUS0(9), profile10-AnnexA-R-POTS-D-64-EU-64-17a(10), profile11-AnnexB-B7-3-997-M1x-M(11), profile12-AnnexB-B7-4-997-M2x-M-8(12), profile13-AnnexB-B7-5-997-M2x-A(13), profile14-AnnexB-B7-6-997-M2x-M(14), profile15-AnnexB-B7-9-997E17-M2x-A(15), profile16-AnnexB-B7-10-997E30-M2x-NUS0(16), profile17-AnnexB-B8-1-998-M1x-A(17), profile18-AnnexB-B8-2-998-M1x-B(18), profile19-AnnexB-B8-4-998-M2x-A(19), profile20-AnnexB-B8-5-998-M2x-M(20), profile21-AnnexB-B8-6-998-M2x-B(21), profile22-AnnexB-B8-8-998E17-M2x-NUS0(22), profile23-AnnexB-B8-9-998E17-M2x-NUS0-M(23), profile24-AnnexB-B8-10-998ADE17-M2x-NUS0-M(24), profile25-AnnexB-B8-11-998E17-M2x-A(25), profile26-AnnexB-B8-12-998E17-M2x-B(26), profile27-AnnexB-B8-13-998E30-M2x-NUS0(27), profile28-AnnexB-B8-14-998E30-M2x-NUS0-M(28), profile29-AnnexB-B8-15-998ADE30-M2x-NUS0-M(29), profile30-AnnexB-B8-16-998ADE30-M2x-NUS0-A(30), profile31-AnnexC-POTS-25-138-b(31), profile32-AnnexC-POTS-25-276-b(32), profile33-AnnexC-TMC-ISDN(33)} | read-write | current |
| exCMConfigVdslOverrideProfile OBJECT-TYPE This object specifies whether to override advanced VDSL profile settings (e.g exCMConfigVdslSignalToNoiseRatioUp). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.14 | EnableDisableValue | read-write | current |
| exCMConfigVdslSignalToNoiseRatioUp OBJECT-TYPE This object represents the advanced VDSL profile setting signal-to-noise ratio (upstream) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.15 | Integer32 (30..240) | read-write | current |
| exCMConfigVdslMinDataRateUp OBJECT-TYPE This object represents the advanced VDSL profile setting minimum data rate (upstream) in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.16 | Integer32 (128..101064) | read-write | current |
| exCMConfigVdslMaxDataRateUp OBJECT-TYPE This object represents the advanced VDSL profile setting maximum data rate (upstream) in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.17 | Integer32 (128..101064) | read-write | current |
| exCMConfigVdslMaxInterleaveDelayUp OBJECT-TYPE This object represents the advanced VDSL profile setting maximum delay (upstream) in ms. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.18 | Integer32 (0..16) | read-write | current |
| exCMConfigVdslMinInpUp OBJECT-TYPE This object represents the advanced VDSL profile setting minimum INP (impulse noise protection) (upstream). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.19 | Integer32 (1..18) | read-write | current |
| exCMConfigVdslSignalToNoiseRatioDown OBJECT-TYPE This object represents the advanced VDSL profile setting signal-to-noise ratio (downstream) in 0.1 dB. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.20 | Integer32 (30..240) | read-write | current |
| exCMConfigVdslMinDataRateDown OBJECT-TYPE This object represents the advanced VDSL profile setting minimum data rate (downstream) in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.21 | Integer32 (128..101064) | read-write | current |
| exCMConfigVdslMaxDataRateDown OBJECT-TYPE This object represents the advanced VDSL profile setting maximum data rate (downstream) in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.22 | Integer32 (128..101064) | read-write | current |
| exCMConfigVdslMaxInterleaveDelayDown OBJECT-TYPE This object represents the advanced VDSL profile setting maximum delay (downstream) in ms. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.23 | Integer32 (0..16) | read-write | current |
| exCMConfigVdslMinInpDown OBJECT-TYPE This object represents the advanced VDSL profile setting minimum INP (impulse noise protection) (downstream). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.24 | Integer32 (1..18) | read-write | current |
| exCMConfigVdslBitswapping OBJECT-TYPE This object represents the advanced VDSL profile setting bitswapping. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.25 | EnableDisableValue | read-write | current |
| exCMConfigVdslLowBandwidthAlarmUp OBJECT-TYPE This object represents the VDSL low bandwidth alarm threshold (upstream) in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.26 | Integer32 (0..90000) | read-write | current |
| exCMConfigVdslLowBandwidthAlarmDown OBJECT-TYPE This object represents the VDSL low bandwidth alarm threshold (downstream) in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.27 | Integer32 (0..90000) | read-write | current |
| exCMConfigEthernetPortName OBJECT-TYPE This object identifies a user definable name for the ethernet port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.28 | DisplayString (SIZE(0..8)) | read-write | current |
| exCMConfigEthernetPortEnable OBJECT-TYPE This object identifies whether the VDSL port is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.29 | YesNoValue | read-write | current |
| exCMConfigEthernetAutoNegotiation OBJECT-TYPE This object identifies the whether ethernet auto-negotiation is enabled. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.30 | EnableDisableValue | read-write | current |
| exCMConfigEthernetAutoNegAdv10HDX OBJECT-TYPE This object controls whether or the ethernet port advertises willingness to connect at 10Mbps, half duplex. This setting is ignored when auto-negotiation is disabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.31 | YesNoValue | read-write | current |
| exCMConfigEthernetAutoNegAdv10FDX OBJECT-TYPE This object controls whether or the ethernet port advertises willingness to connect at 10Mbps, full duplex. This setting is ignored when auto-negotiation is disabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.32 | YesNoValue | read-write | current |
| exCMConfigEthernetAutoNegAdv100HDX OBJECT-TYPE This object controls whether or the ethernet port advertises willingness to connect at 100Mbps, half duplex. This setting is ignored when auto-negotiation is disabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.33 | YesNoValue | read-write | current |
| exCMConfigEthernetAutoNegAdv100FDX OBJECT-TYPE This object controls whether or the ethernet port advertises willingness to connect at 100Mbps, full duplex. This setting is ignored when auto-negotiation is disabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.34 | YesNoValue | read-write | current |
| exCMConfigEthernetAutoNegAdv1000FDX OBJECT-TYPE This object controls whether or the ethernet port advertises willingness to connect at 1000Mbps, full duplex. This setting is ignored when auto-negotiation is disabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.35 | YesNoValue | read-write | current |
| exCMConfigEthernetSpeed OBJECT-TYPE If ethernet auto-negotiation is disabled then this object identifies the configured cooper speed. 1000 Mbps speed can only be auto negotiated. If ethernet auto-negotiation is enabled then this object is ignored. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.36 | INTEGER {speed10Mbs(0), speed100Mbps(1)} | read-write | current |
| exCMConfigEthernetDuplex OBJECT-TYPE If ethernet auto-negotiation is disabled then this object identifies the duplex setting for 10 & 100 Mbps for the ethernet port. Duplex for 1000 Mbps has to be auto negotiated. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.37 | INTEGER {full(0), half(1)} | read-write | current |
| exCMConfigEthernetCrossOver OBJECT-TYPE This object identifies the ethernet MDI/MDI-X setting.This object is read-only if the media converter module's ConfigMode jumper is set to | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.38 | INTEGER {auto(0), mdi(1), mdix(2)} | read-write | current |
| exCMConfigEthernetPauseEnh OBJECT-TYPE This object identifies the ethernet pause (flow control) setting that is a advertised. The settings can be disabled, advertise symmetrical, advertise asymmetrical TX or advertise symmetrical and asymmetrical RX. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.39 | INTEGER {disabled(0), symmetrical(1), asymmetricalTx(2), symmAsymRx(3)} | read-write | current |
| exCMConfigEthernetAutoSpeedDownshift OBJECT-TYPE This object identifies the number of times the PHY attempts to establish a Gigabit link before the PHY downshift to the next highest speed. A value of 0 indicates the auto downshift is disabled | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.40 | INTEGER (0..8) | read-write | current |
| exCMConfigEthernet10BaseTDistance OBJECT-TYPE When using cable exceeding 100 meters in 10BASE-T mode this feature should be set to extended(1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.41 | INTEGER {normal(0), extended(1)} | read-write | current |
| exCMConfigUnidirectionalEthernet OBJECT-TYPE Restrict the flow of Ethernet traffic to a single direction. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.42 | INTEGER {notApplicable(-1), disabled(0), ethernetToVdsl(1), vdslToEthernet(2)} | read-write | current |
| exCMConfigPriorityToEgressQueueMap0 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.43 | INTEGER (0..3) | read-write | current |
| exCMConfigPriorityToEgressQueueMap1 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.44 | INTEGER (0..3) | read-write | current |
| exCMConfigPriorityToEgressQueueMap2 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.45 | INTEGER (0..3) | read-write | current |
| exCMConfigPriorityToEgressQueueMap3 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.46 | INTEGER (0..3) | read-write | current |
| exCMConfigPriorityToEgressQueueMap4 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.47 | INTEGER (0..3) | read-write | current |
| exCMConfigPriorityToEgressQueueMap5 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.48 | INTEGER (0..3) | read-write | current |
| exCMConfigPriorityToEgressQueueMap6 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.49 | INTEGER (0..3) | read-write | current |
| exCMConfigPriorityToEgressQueueMap7 OBJECT-TYPE Set the egress queue of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.50 | INTEGER (0..3) | read-write | current |
| exCMConfigEthernet8021pPriority OBJECT-TYPE Use 802.1p tag priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.51 | OnOffValue | read-write | current |
| exCMConfigEthernetIpTosPriority OBJECT-TYPE Use IP TOS priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.52 | OnOffValue | read-write | current |
| exCMConfigEthernetPriorityPrecedence OBJECT-TYPE Configure priority precedence. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.53 | INTEGER {notApplicable(-1), priority8021p(0), priorityIpTos(1)} | read-write | current |
| exCMConfigEthernetCongestionPolicy OBJECT-TYPE Configure priority congestion policy. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.54 | INTEGER {notApplicable(-1), strict(0), weighted(1)} | read-write | current |
| exCMConfigEthernetPriorityMap0 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.55 | INTEGER (0..7) | read-write | current |
| exCMConfigEthernetPriorityMap1 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.56 | INTEGER (0..7) | read-write | current |
| exCMConfigEthernetPriorityMap2 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.57 | INTEGER (0..7) | read-write | current |
| exCMConfigEthernetPriorityMap3 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.58 | INTEGER (0..7) | read-write | current |
| exCMConfigEthernetPriorityMap4 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.59 | INTEGER (0..7) | read-write | current |
| exCMConfigEthernetPriorityMap5 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.60 | INTEGER (0..7) | read-write | current |
| exCMConfigEthernetPriorityMap6 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.61 | INTEGER (0..7) | read-write | current |
| exCMConfigEthernetPriorityMap7 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.62 | INTEGER (0..7) | read-write | current |
| exCMConfigEthernetIngressLimit OBJECT-TYPE Set a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.63 | INTEGER {notApplicable(-1), rateUnlimited(0), rate64kbps(1), rate128kbps(2), rate192kbps(3), rate256kbps(4), rate320kbps(5), rate384kbps(6), rate512kbps(7), rate768kbps(8), rate1mbps(9), rate2mbps(10), rate3mbps(11), rate4mbps(12), rate5mbps(13), rate6mbps(14), rate7mbps(15), rate8mbps(16), rate9mbps(17), rate10mbps(18), rate20mbps(19), rate30mbps(20), rate40mbps(21), rate50mbps(22), rate60mbps(23), rate70mbps(24), rate80mbps(25), rate90mbps(26)} | read-write | current |
| exCMConfigEthernetEgressLimit OBJECT-TYPE Set a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.64 | INTEGER {notApplicable(-1), rateUnlimited(0), rate64kbps(1), rate128kbps(2), rate192kbps(3), rate256kbps(4), rate320kbps(5), rate384kbps(6), rate512kbps(7), rate768kbps(8), rate1mbps(9), rate2mbps(10), rate3mbps(11), rate4mbps(12), rate5mbps(13), rate6mbps(14), rate7mbps(15), rate8mbps(16), rate9mbps(17), rate10mbps(18), rate20mbps(19), rate30mbps(20), rate40mbps(21), rate50mbps(22), rate60mbps(23), rate70mbps(24), rate80mbps(25), rate90mbps(26)} | read-write | current |
| exCMConfigEthernetDiscardTaggedFrames OBJECT-TYPE Enable discarding of tagged frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.65 | OnOffValue | read-write | current |
| exCMConfigEthernetDiscardUntaggedFrames OBJECT-TYPE Enable discarding of untagged frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.66 | OnOffValue | read-write | current |
| exCMConfigEthernetDefaultVlanId OBJECT-TYPE Set the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.67 | INTEGER (0..4095) | read-write | current |
| exCMConfigEthernetDefaultPriority OBJECT-TYPE Set the default frame priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.68 | INTEGER (0..7) | read-write | current |
| exCMConfigEthernetVlanTaggingAction OBJECT-TYPE Set the default tagging action. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.69 | INTEGER {notApplicable(-1), none(0), untag(1), tag(2), doubleTag(3)} | read-write | current |
| exCMConfigEthernetFilterUnknownMulticast OBJECT-TYPE Enable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.70 | OnOffValue | read-write | current |
| exCMConfigEthernetFilterUnknownUnicast OBJECT-TYPE Enable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.71 | OnOffValue | read-write | current |
| exCMConfigVdsl8021pPriority OBJECT-TYPE Use 802.1p tag priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.72 | OnOffValue | read-write | current |
| exCMConfigVdslIpTosPriority OBJECT-TYPE Use IP TOS priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.73 | OnOffValue | read-write | current |
| exCMConfigVdslPriorityPrecedence OBJECT-TYPE Configure priority precedence. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.74 | INTEGER {notApplicable(-1), priority8021p(0), priorityIpTos(1)} | read-write | current |
| exCMConfigVdslCongestionPolicy OBJECT-TYPE Configure priority congestion policy. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.75 | INTEGER {notApplicable(-1), strict(0), weighted(1)} | read-write | current |
| exCMConfigVdslPriorityMap0 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 0. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.76 | INTEGER (0..7) | read-write | current |
| exCMConfigVdslPriorityMap1 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 1. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.77 | INTEGER (0..7) | read-write | current |
| exCMConfigVdslPriorityMap2 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 2. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.78 | INTEGER (0..7) | read-write | current |
| exCMConfigVdslPriorityMap3 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 3. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.79 | INTEGER (0..7) | read-write | current |
| exCMConfigVdslPriorityMap4 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 4. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.80 | INTEGER (0..7) | read-write | current |
| exCMConfigVdslPriorityMap5 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 5. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.81 | INTEGER (0..7) | read-write | current |
| exCMConfigVdslPriorityMap6 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 6. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.82 | INTEGER (0..7) | read-write | current |
| exCMConfigVdslPriorityMap7 OBJECT-TYPE Change the priority of frames tagged with 802.1p priority 7. A value of -1 signifies that this feature is not supported by the current media converter module firmware. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.83 | INTEGER (0..7) | read-write | current |
| exCMConfigVdslIngressLimit OBJECT-TYPE Set a limit on the rate of incoming packets. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.84 | INTEGER {notApplicable(-1), rateUnlimited(0), rate64kbps(1), rate128kbps(2), rate192kbps(3), rate256kbps(4), rate320kbps(5), rate384kbps(6), rate512kbps(7), rate768kbps(8), rate1mbps(9), rate2mbps(10), rate3mbps(11), rate4mbps(12), rate5mbps(13), rate6mbps(14), rate7mbps(15), rate8mbps(16), rate9mbps(17), rate10mbps(18), rate20mbps(19), rate30mbps(20), rate40mbps(21), rate50mbps(22), rate60mbps(23), rate70mbps(24), rate80mbps(25), rate90mbps(26)} | read-write | current |
| exCMConfigVdslEgressLimit OBJECT-TYPE Set a limit on the rate of outgoing packets. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.85 | INTEGER {notApplicable(-1), rateUnlimited(0), rate64kbps(1), rate128kbps(2), rate192kbps(3), rate256kbps(4), rate320kbps(5), rate384kbps(6), rate512kbps(7), rate768kbps(8), rate1mbps(9), rate2mbps(10), rate3mbps(11), rate4mbps(12), rate5mbps(13), rate6mbps(14), rate7mbps(15), rate8mbps(16), rate9mbps(17), rate10mbps(18), rate20mbps(19), rate30mbps(20), rate40mbps(21), rate50mbps(22), rate60mbps(23), rate70mbps(24), rate80mbps(25), rate90mbps(26)} | read-write | current |
| exCMConfigVdslDiscardTaggedFrames OBJECT-TYPE Enable discarding of tagged frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.86 | OnOffValue | read-write | current |
| exCMConfigVdslDiscardUntaggedFrames OBJECT-TYPE Enable discarding of untagged frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.87 | OnOffValue | read-write | current |
| exCMConfigVdslDefaultVlanId OBJECT-TYPE Set the default VLAN ID to insert when tagging frames. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.88 | INTEGER (0..4095) | read-write | current |
| exCMConfigVdslDefaultPriority OBJECT-TYPE Set the default frame priority. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.89 | INTEGER (0..7) | read-write | current |
| exCMConfigVdslVlanTaggingAction OBJECT-TYPE Set the default tagging action. (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.90 | INTEGER {notApplicable(-1), none(0), untag(1), tag(2), doubleTag(3)} | read-write | current |
| exCMConfigVdslFilterUnknownMulticast OBJECT-TYPE Enable filtering of multicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.91 | OnOffValue | read-write | current |
| exCMConfigVdslFilterUnknownUnicast OBJECT-TYPE Enable filtering of unicast frames with an unknown destination (This feature may require a media converter module firmware upgrade). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.92 | OnOffValue | read-write | current |
| exCMConfigVdslFastMode OBJECT-TYPE This object represents the VDSL fast mode setting. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.2.1.93 | EnableDisableValue | read-write | current |
| exCMLedTable OBJECT-TYPE Table of CM-1110 type media converter module's LED status information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3 | not-accessible | current | |
| exCMLedEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-1110 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1 | not-accessible | current | |
| exCMLedSlotIndex OBJECT-TYPE The Slot number of the module | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.2 | SlotNumber | not-accessible | current |
| exCMLedILNK OBJECT-TYPE This object identifies the status of the ILNK (InterLink) LED on the media converter module. Possible status values are: slowBlinkingGreen(1) - ILNK port is idle or handshaking fastBlinkingGreen(2) - ILNK port is training green(3) - ILNK port is up | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.3 | INTEGER {off(0), slowBlinkingGreen(1), fastBlinkingGreen(2), green(3)} | read-only | current |
| exCMLedLOC OBJECT-TYPE This object identifies the status of the Local (LOC) LED on the media converter module. When this LED is green, it indicates that the InterLink port's VDSL role is local. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.4 | INTEGER {off(0), green(1)} | read-only | current |
| exCMLedPWR OBJECT-TYPE This object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - InterLink loopback enabled | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.5 | INTEGER {off(0), onGreen(1), blinking(2)} | read-only | current |
| exCMLedETH OBJECT-TYPE This object identifies the status of the ETH (Ethernet) LED on the media converter module. Possible status values are: off(0) - ETH port is down slowBlinkingGreen(1) - ETH port is down, due to the VDSL port or peer copper ethernet port being down green(2) - ETH port is up | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.6 | INTEGER {off(0), slowBlinkingGreen(1), green(2)} | read-only | current |
| exCMLedRMT OBJECT-TYPE This object identifies the status of the Remote (RMT) LED on the media converter module. When this LED is green, it indicates that the InterLink port's VDSL role is remote. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.3.1.7 | INTEGER {off(0), green(1)} | read-only | current |
| exCMStatsTable OBJECT-TYPE Table of CM-1110 type media converter module's configuration and status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4 | not-accessible | current | |
| exCMStatsEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-1110 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1 | not-accessible | current | |
| exCMStatsSlotIndex OBJECT-TYPE The Slot number the ex-1CM type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.2 | SlotNumber | not-accessible | current |
| exCMMediaPortIndex OBJECT-TYPE Media converter module port index indicating which media port the statistical counters are associated with. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.3 | INTEGER (1..2) | not-accessible | current |
| exCMPortInDiscards OBJECT-TYPE A counter that counts the number of good, non-filtered frames that normally would have been forwarded, but could not due to lack of buffer space. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.4 | Counter32 | read-only | current |
| exCMPortInFiltered OBJECT-TYPE A counter that counts the number of good frames that were filtered due to ingress switch policy rules. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.5 | INTEGER (0..65535) | read-only | current |
| exCMPortInGoodOctets OBJECT-TYPE An ingress counter that is the sum of lengths of all good Ethernet frames received on the media port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.6 | Counter32 | read-only | current |
| exCMPortHCInGoodOctets OBJECT-TYPE An ingress counter that is the sum of lengths of all good Ethernet frames received on the media port. This object is a 64-bit version of exCMPortInGoodOctets. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.7 | Counter64 | read-only | current |
| exCMPortInBadOctets OBJECT-TYPE An ingress counter that is the sum of lengths of all bad Ethernet frames received on the media port.. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.8 | Counter32 | read-only | current |
| exCMPortInUnicasts OBJECT-TYPE An ingress counter that counts the number of good frames received that have a Unicast destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.9 | Counter32 | read-only | current |
| exCMPortInBroadcasts OBJECT-TYPE An ingress counter that counts the number of good frames received that have a Broadcast destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.10 | Counter32 | read-only | current |
| exCMPortInMulticasts OBJECT-TYPE An ingress counter that counts the number of good frames received that have a Multicast destination MAC address. This count does not include frames counted in the exCMPortInPauses or the exCMPortInBroadcasts objects. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.11 | Counter32 | read-only | current |
| exCMPortInPauses OBJECT-TYPE An ingress counter that counts the number of good frames reachieved that have a Pause destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.12 | Counter32 | read-only | current |
| exCMPortInUnderSizes OBJECT-TYPE An ingress counter that counts the number of frames received with a length less that 64 octets but with a valid FCS. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.13 | Counter32 | read-only | current |
| exCMPortInFragments OBJECT-TYPE An ingress counter that counts the number of frames received with a length less that 64 octets and an invalid FCS. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.14 | Counter32 | read-only | current |
| exCMPortInOversizes OBJECT-TYPE An ingress counter that counts the number of frames received with a length more than the maximum packet size but with a valid FCS. The maximum packet size can be set using the exCMConfigMaxPacketsSize object. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.15 | Counter32 | read-only | current |
| exCMPortInJabbers OBJECT-TYPE An ingress counter that counts the number of frames received with a length more than the maximum packet size but with a invalid FCS. The maximum packet size can be set using the exCMConfigMaxPacketsSize object. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.16 | Counter32 | read-only | current |
| exCMPortInRxErrs OBJECT-TYPE An ingress counter that counts the number of frames received with an RxErr signal from the PHY. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.17 | Counter32 | read-only | current |
| exCMPortInFcsErrs OBJECT-TYPE An ingress counter that counts the number of frames received with a CRC error not counted in the exCMPortInFragments, exCMPortInFcsErr, or the exCMPortInRxErr objects. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.18 | Counter32 | read-only | current |
| exCMPortPkts64Octets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of exactly 64 Octets, including those with errors. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.19 | Counter32 | read-only | current |
| exCMPortPkts65to127Octets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of between 65 and 127 Octets inclusive, including those with errors. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.20 | Counter32 | read-only | current |
| exCMPortPkts128to255Octets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of between 128 and 255 Octets inclusive, including those with errors. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.21 | Counter32 | read-only | current |
| exCMPortPkts256to511Octets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of between 256 and 511 Octets inclusive, including those with errors. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.22 | Counter32 | read-only | current |
| exCMPortPkts512to1023Octets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of between 512 and 1023 Octets inclusive, including those with errors. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.23 | Counter32 | read-only | current |
| exCMPortPkts1024toMaxOctets OBJECT-TYPE A Histogram counter that counts the number of frames received and transmitted with a length of between 1024 and maximum packet size octets inclusive, including those with errors. The maximum packet size can be set using the exCMConfigMaxPacketsSize object. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.24 | Counter32 | read-only | current |
| exCMPortOutOctets OBJECT-TYPE An Egress counter that is the sum of lengths of all good Ethernet frames sent on the media port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.25 | Counter32 | read-only | current |
| exCMPortHCOutOctets OBJECT-TYPE An Egress counter that is the sum of lengths of all good Ethernet frames sent on the media port. This object is a 64-bit version of exCMPortOutOctets. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.26 | Counter64 | read-only | current |
| exCMPortOutFiltered OBJECT-TYPE A counter that counts the number of good frames that were filtered due to egress switch policy rules. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.27 | INTEGER (0..65535) | read-only | current |
| exCMPortOutUnicasts OBJECT-TYPE An Egress counter that counts the number of good frames sent that have a Unicast destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.28 | Counter32 | read-only | current |
| exCMPortOutBroadcasts OBJECT-TYPE An Egress counter that counts the number of good frames sent that have a Broadcast destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.29 | Counter32 | read-only | current |
| exCMPortOutMulticasts OBJECT-TYPE An Egress counter that counts the number of good frames sent that have a Multicast destination MAC address. This count does not include frames counted in the exCMPortOutPauses or the exCMPortOutBroadcasts objects. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.30 | Counter32 | read-only | current |
| exCMPortOutPauses OBJECT-TYPE An Egress counter that counts the number of good frames reachieved that have a Pause destination MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.31 | Counter32 | read-only | current |
| exCMPortDeferreds OBJECT-TYPE An Egress counter that counts the number of successfully transmitted frames that experienced no collisions but are delayed because the medium was busy during the first attempt. This counter is applicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.32 | Counter32 | read-only | current |
| exCMPortCollisions OBJECT-TYPE An Egress counter that counts the number of collision events seen by the MAC not including those counted in exCMPortSingles, exCMPortMultiple , exCMPortExcessives or exCMPortLates objects. This counter is applicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.33 | Counter32 | read-only | current |
| exCMPortSingles OBJECT-TYPE An Egress counter that counts the number of successfully transmitted frames that experienced exactly one collision. This counter is applicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.34 | Counter32 | read-only | current |
| exCMPortMultiples OBJECT-TYPE An Egress counter that counts the number of successfully transmitted frames that experienced more than one collision. This counter is aplicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.35 | Counter32 | read-only | current |
| exCMPortExcessives OBJECT-TYPE An Egress counter that counts the number frames dropped in the transmit MAC because the frame experienced 16 consecutive collisions. This counter is applicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.36 | Counter32 | read-only | current |
| exCMPortLates OBJECT-TYPE An Egress counter that counts the number times a collision is detected later than 512 bits-times into the transmission of a frame. This counter is applicable in half-duplex only. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.37 | Counter32 | read-only | current |
| exCMPortOutFcsErrs OBJECT-TYPE An Egress counter that counts the number frames transmitted with an invalid FCS. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.38 | Counter32 | read-only | current |
| exCMPortResetCounters OBJECT-TYPE Allows the resetting of all exCMStats statistical counters for this port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.4.1.39 | YesNoValue | read-write | current |
| exCMVdslStatsTable OBJECT-TYPE Table of CM-1110 type media converter module's configuration and status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5 | not-accessible | current | |
| exCMVdslStatsEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-1110 type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1 | not-accessible | current | |
| exCMVdslStatsSlotIndex OBJECT-TYPE The Slot number the ex-1CM type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.2 | SlotNumber | not-accessible | current |
| exCMVdslStatsMediaPortIndex OBJECT-TYPE Media converter module port index indicating which media port the statistical counters are associated with. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.3 | Unsigned32 | not-accessible | current |
| exCMVdslStatsTimePeriod OBJECT-TYPE Media converter module port index indicating which media port the statistical counters are associated with. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.4 | INTEGER {sinceLinkup(1), current15Minutes(2), previous15Minutes(3), current24Hours(4), previous24Hours(5)} | read-only | current |
| exCMVdslStatsFullInitLocal OBJECT-TYPE The VDSL port's fully initialized (local) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.5 | Integer32 | read-only | current |
| exCMVdslStatsCodeViolationLocal OBJECT-TYPE The VDSL port's code violation (local) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.6 | Integer32 | read-only | current |
| exCMVdslStatsCorrectedLocal OBJECT-TYPE The VDSL port's corrected (local) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.7 | Integer32 | read-only | current |
| exCMVdslStatsFecSecsLocal OBJECT-TYPE The VDSL port's forward error correction seconds (local) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.8 | Integer32 | read-only | current |
| exCMVdslStatsErroredSecsLocal OBJECT-TYPE The VDSL port's errored seconds (local) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.9 | Integer32 | read-only | current |
| exCMVdslStatsSeverelyErroredSecsLocal OBJECT-TYPE The VDSL port's severely errored seconds (local) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.10 | Integer32 | read-only | current |
| exCMVdslStatsLossOfSignalSecsLocal OBJECT-TYPE The VDSL port's loss of signal seconds (local) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.11 | Integer32 | read-only | current |
| exCMVdslStatsUnavailableSecsLocal OBJECT-TYPE The VDSL port's unavailable seconds (local) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.12 | Integer32 | read-only | current |
| exCMVdslStatsTimeElapsedLocal OBJECT-TYPE The VDSL port's elapsed time in seconds (local) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.13 | Integer32 | read-only | current |
| exCMVdslStatsFullInitRemote OBJECT-TYPE The VDSL port's fully initialized (remote) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.14 | Integer32 | read-only | current |
| exCMVdslStatsCodeViolationRemote OBJECT-TYPE The VDSL port's code violation (remote) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.15 | Integer32 | read-only | current |
| exCMVdslStatsCorrectedRemote OBJECT-TYPE The VDSL port's corrected (remote) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.16 | Integer32 | read-only | current |
| exCMVdslStatsFecSecsRemote OBJECT-TYPE The VDSL port's forward error correction seconds (remote) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.17 | Integer32 | read-only | current |
| exCMVdslStatsErroredSecsRemote OBJECT-TYPE The VDSL port's errored seconds (remote) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.18 | Integer32 | read-only | current |
| exCMVdslStatsSeverelyErroredSecsRemote OBJECT-TYPE The VDSL port's severely errored seconds (remote) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.19 | Integer32 | read-only | current |
| exCMVdslStatsLossOfSignalSecsRemote OBJECT-TYPE The VDSL port's loss of signal seconds (remote) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.20 | Integer32 | read-only | current |
| exCMVdslStatsUnavailableSecsRemote OBJECT-TYPE The VDSL port's unavailable seconds (remote) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.21 | Integer32 | read-only | current |
| exCMVdslStatsTimeElapsedRemote OBJECT-TYPE The VDSL port's elapsed time in seconds (remote) count. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.5.1.22 | Integer32 | read-only | current |
| exCMAvctTable OBJECT-TYPE Table of ex-CM media converter modules. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6 | not-accessible | current | |
| exCMAvctEntry OBJECT-TYPE Entries of the table, each relating to a copper Ethernet port on the eX-CM type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1 | not-accessible | current | |
| exCMAvctSlotIndex OBJECT-TYPE The Slot number the eX-CM type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.2 | SlotNumber | not-accessible | current |
| exCMAvctStart OBJECT-TYPE Set this self-clearing variable to yes initiate the Advanced Virtual Cable Test. Note: During the test, no network data will be passed. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.3 | YesNoValue | read-write | current |
| exCMAvctStatus OBJECT-TYPE This object identifies the state of the Advanced Virtual Cable Tester. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.4 | INTEGER {notStarted(0), inProgress(1), testComplete(2)} | read-only | current |
| exCMAvctTxRxPair1Results OBJECT-TYPE Test result code returned from Virtual Cable Test of the Tx/Rx pair one. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.5 | INTEGER {normal(0), shortDetected(1), openDetected(2), testFailed(3)} | read-only | current |
| exCMAvctTxRxPair1Amplitude OBJECT-TYPE Amplitude of Tx/Rx pair one in millivolts when test result codes is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.6 | DisplayString (SIZE(0..20)) | read-only | current |
| exCMAvctTxRxPair1Distance OBJECT-TYPE Distance in meters to fault when test result codes for Tx/Rx pair one is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.7 | DisplayString (SIZE(0..20)) | read-only | current |
| exCMAvctTxRxPair2Results OBJECT-TYPE Test result code returned from Virtual Cable Test of the Tx/Rx pair two. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.8 | INTEGER {normal(0), shortDetected(1), openDetected(2), testFailed(3)} | read-only | current |
| exCMAvctTxRxPair2Amplitude OBJECT-TYPE Amplitude of Tx/Rx pair two in millivolts when test result codes is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.9 | DisplayString (SIZE(0..20)) | read-only | current |
| exCMAvctTxRxPair2Distance OBJECT-TYPE Distance in meters to fault when test result codes for Tx/Rx pair two is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.10 | DisplayString (SIZE(0..20)) | read-only | current |
| exCMAvctTxRxPair3Results OBJECT-TYPE Test result code returned from Virtual Cable Test of the Tx/Rx pair three. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.11 | INTEGER {normal(0), shortDetected(1), openDetected(2), testFailed(3)} | read-only | current |
| exCMAvctTxRxPair3Amplitude OBJECT-TYPE Amplitude of Tx/Rx pair three in millivolts when test result codes is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.12 | DisplayString (SIZE(0..20)) | read-only | current |
| exCMAvctTxRxPair3Distance OBJECT-TYPE Distance in meters to fault when test result codes for Tx/Rx pair three is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.13 | DisplayString (SIZE(0..20)) | read-only | current |
| exCMAvctTxRxPair4Results OBJECT-TYPE Test result code returned from Virtual Cable Test of Tx/Rx pair four. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.14 | INTEGER {normal(0), shortDetected(1), openDetected(2), testFailed(3)} | read-only | current |
| exCMAvctTxRxPair4Amplitude OBJECT-TYPE Amplitude of Tx/Rx pair four in millivolts when test result codes is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.15 | DisplayString (SIZE(0..20)) | read-only | current |
| exCMAvctTxRxPair4Distance OBJECT-TYPE Distance in meters to fault when test result codes for Tx/Rx pair four is short or open. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.9.6.1.16 | DisplayString (SIZE(0..20)) | read-only | current |
| cm10gt OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10 | |||
| cm10gtTable OBJECT-TYPE Table of CM-10G type media converter module's status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1 | not-accessible | current | |
| cm10gtEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-10G type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1 | not-accessible | current | |
| cm10gtSlotIndex OBJECT-TYPE The Slot number the CM-10G type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.2 | SlotNumber | not-accessible | current |
| cm10gtModelname OBJECT-TYPE This object identifies the model of media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.3 | DisplayString | read-only | current |
| cm10gtModelDesc OBJECT-TYPE This object identifies a static description of the media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.4 | DisplayString | read-only | current |
| cm10gtHwJmp5ConfigMode OBJECT-TYPE This object identifies the media converter module's ConfigMode, set by hardware jumper J5 on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media converter module's hardware switches or jumpers. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.5 | INTEGER {hardwareSwitches(0), auto(1)} | read-only | current |
| cm10gtHwSw1OperationMode OBJECT-TYPE Media converter module's current switch setting for operation mode. Data mode is for normal data transmission. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.6 | INTEGER {test(0), data(1)} | read-only | current |
| cm10gtHwSw2LinkMode OBJECT-TYPE Media converter module's current switch setting for Link Mode. If the Operation switch is set to Test, then this object indicates whether the port is in loopback or performing the build in link-test. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.7 | INTEGER {swDownSmartLinkPassthrough(0), swUpStandard(1)} | read-only | current |
| cm10gtHwSw3FiberFaultAlert OBJECT-TYPE Media converter module's current switch setting for Fiber Fault Alert. If the Operation switch is set to Test, then this object indicates which port is in test mode | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.8 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| cm10gtHwSw4EnergyEfficentEthernet OBJECT-TYPE This object indicates the current switch setting for Energy Efficient Ethernet on port 2. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.9 | INTEGER {disabled(0), enabled(1)} | read-only | current |
| cm10gtHwSw5Unused OBJECT-TYPE This object indicates the current switch setting for dip switch 5, which is unused. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.10 | INTEGER {disabled(0), enabled(1)} | read-only | current |
| cm10gtPort1LinkStatus OBJECT-TYPE Media converter module's current fiber link status (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.11 | INTEGER {down(0), up(1), shutdown(2)} | read-only | current |
| cm10gtPort1ConnType OBJECT-TYPE Media converter module's fiber port connector type (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.12 | INTEGER {sc(0), lc(1), st(2), sfp(3), fc(5), mtrj(6), xfp(7), sfpPlus(8)} | read-only | current |
| cm10gtPort1AutoNegState OBJECT-TYPE Media converter module's current fiber auto-negotiation state (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.13 | INTEGER {disabled(0), complete(1), inProgress(2)} | read-only | current |
| cm10gtPort1Speed OBJECT-TYPE Media converter module's fiber port speed in megabits per second (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.14 | INTEGER {speed10Mbps(0), speed100Mbps(1), speed1000Mbps(2), speed10Gbps(3)} | read-only | current |
| cm10gtPort1Duplex OBJECT-TYPE If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.15 | INTEGER {half(0), full(1)} | read-only | current |
| cm10gtPort1PauseEnh OBJECT-TYPE If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 1) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.16 | INTEGER {disabled(0), symmetrical(1), asymmetricalTx(2), asymmetricalRx(3)} | read-only | current |
| cm10gtPort1ReceiveStatus OBJECT-TYPE This object identifies the status of whether light is being received on the fiber port (port 1) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.17 | INTEGER {fault(0), ok(1)} | read-only | current |
| cm10gtPort1LPRFStatus OBJECT-TYPE Media converter module's Link Partner Remote Fault status (port 1). This object only applies to SFP modules running at 1G, with auto-negotiation enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.18 | INTEGER {notApplicable(-1), ok(0), offline(1), linkFault(2), autoNegError(3)} | read-only | current |
| cm10gtPort2LinkStatus OBJECT-TYPE Media converter module's current fiber link status (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.19 | INTEGER {down(0), up(1), shutdown(2)} | read-only | current |
| cm10gtPort2ConnType OBJECT-TYPE Media converter module's fiber port connector type (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.20 | INTEGER {rj45(4)} | read-only | current |
| cm10gtPort2AutoNegState OBJECT-TYPE Media converter module's current fiber auto-negotiation state (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.21 | INTEGER {disabled(0), complete(1), inProgress(2)} | read-only | current |
| cm10gtPort2Speed OBJECT-TYPE Media converter module's fiber port speed in megabits per second (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.22 | INTEGER {speed10Mbps(0), speed100Mbps(1), speed1000Mbps(2), speed10Gbps(3)} | read-only | current |
| cm10gtPort2Duplex OBJECT-TYPE If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated duplex setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.23 | INTEGER {half(0), full(1)} | read-only | current |
| cm10gtPort2PauseEnh OBJECT-TYPE If fiber auto-negotiation state is complete then this object indicates the media converter module's current fiber auto-negotiated pause setting. If auto-negotiation is not complete then the value returned should be ignored. (Port 2) | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.24 | INTEGER {disabled(0), symmetrical(1), asymmetricalTx(2), asymmetricalRx(3)} | read-only | current |
| cm10gtPort2LPRFStatus OBJECT-TYPE Media converter module's copper Link Partner Remote Fault status. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.25 | INTEGER {ok(0), remoteFault(1)} | read-only | current |
| cm10gtPortLoopBack OBJECT-TYPE Media converter module's current port loopback mode setting. Writing to this object will change the current settings. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.26 | INTEGER {disabled(0), port1(1), port2(2)} | read-write | current |
| cm10gtPortTestMode OBJECT-TYPE Media converter module's current port test mode setting. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.1.1.27 | INTEGER {disabled(0), port1(1)} | read-only | current |
| cm10gtConfigTable OBJECT-TYPE Table of CM-10G type media converter module's configuration type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2 | not-accessible | current | |
| cm10gtConfigEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-10G type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1 | not-accessible | current | |
| cm10gtConfigSlotIndex OBJECT-TYPE The Slot number the CM-10G type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.2 | SlotNumber | not-accessible | current |
| cm10gtConfigStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.3 | ContainerStatus | read-write | current |
| cm10gtConfigModuleName OBJECT-TYPE This object identifies a user configurable name for the media converter module present in the chassis. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.4 | DisplayString (SIZE(0..63)) | read-write | current |
| cm10gtConfigLinkMode OBJECT-TYPE This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.5 | INTEGER {standard(0), smartLinkPassthrough(1)} | read-write | current |
| cm10gtConfigFiberFaultAlert OBJECT-TYPE This object identifies the Fiber Fault Alert setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.6 | EnableDisableValue | read-write | current |
| cm10gtConfigFiberAutoNeg OBJECT-TYPE This object identifies the wither fiber auto-negotiation is enabled for both ports. This only applies if 1G SFP modules are in use. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.7 | EnableDisableValue | read-write | current |
| cm10gtConfigPort1Name OBJECT-TYPE This object identifies a user definable name for port 1. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.8 | DisplayString (SIZE(0..8)) | read-write | current |
| cm10gtConfigPort1Enable OBJECT-TYPE This object identifies whether port 1 is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.9 | YesNoValue | read-write | current |
| cm10gtConfigPort1FecEnable OBJECT-TYPE This object identifies the whether FEC control is enabled for this port. This config option only applies for an XFP module. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.10 | YesNoValue | read-write | current |
| cm10gtConfigPort1FecAmplitude OBJECT-TYPE This object identifies the FEC Amplitude value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.11 | INTEGER (-128..127) | read-write | current |
| cm10gtConfigPort1FecPhase OBJECT-TYPE This object identifies the FEC phase value for this port. This config option only applies for an XFP module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.12 | INTEGER (-128..127) | read-write | current |
| cm10gtConfigPort1WavelengthEnable OBJECT-TYPE This object identifies whether Wavelength fine tuning is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.13 | YesNoValue | read-write | current |
| cm10gtConfigPort1WavelengthValue OBJECT-TYPE This object identifies Wavelength fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.14 | INTEGER (0..65535) | read-write | current |
| cm10gtConfigPort1ChannelEnable OBJECT-TYPE This object identifies whether channel number fine tuning is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.15 | YesNoValue | read-write | current |
| cm10gtConfigPort1ChannelNumber OBJECT-TYPE This object identifies the channel number fine tuning value for this port. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.16 | INTEGER (1..65535) | read-write | current |
| cm10gtConfigPort1TxDitherEnable OBJECT-TYPE This object identifies the whether TX Dither control is enabled on this port. If not enabled the default TX Dither value will be used. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.17 | YesNoValue | read-write | current |
| cm10gtConfigPort1TxDitherValue OBJECT-TYPE This object identifies the whether TX Dither is enabled for this port. This object is read-only if the media module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.18 | EnableDisableValue | read-write | current |
| cm10gtConfigPort2Name OBJECT-TYPE This object identifies a user definable name for port 2. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.19 | DisplayString (SIZE(0..8)) | read-write | current |
| cm10gtConfigPort2Enable OBJECT-TYPE This object identifies whether port 2 is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.20 | YesNoValue | read-write | current |
| cm10gtConfigPort2CopperDuplex OBJECT-TYPE This object identifies the duplex settings for the copper port. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.21 | INTEGER {half(1), auto(2)} | read-write | current |
| cm10gtConfigPort2CopperPauseEnh OBJECT-TYPE This object identifies the copper pause (flow control) setting that is a advertised. The settings can be disabled, advertise symmetrical, advertise asymmetrical TX or advertise symmetrical and asymmetrical RX. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.22 | INTEGER {disabled(0), symmetrical(1), asymmetricalTx(2), symmAsymRx(3)} | read-write | current |
| cm10gtConfigPort2CopperEnergyEfficientEthernet OBJECT-TYPE This object identifies the copper Energy-Efficient Ethernet setting for the media converter module present in the chassis. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.2.1.23 | OnOffValue | read-write | current |
| cm10gtLedTable OBJECT-TYPE Table of CM-10G type media converter module's LED status information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3 | not-accessible | current | |
| cm10gtLedEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-10G type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3.1 | not-accessible | current | |
| cm10gtLedsSlotIndex OBJECT-TYPE The Slot number the CM-10G type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3.1.2 | SlotNumber | read-only | current |
| cm10gtLedPWR OBJECT-TYPE This object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Loopback or Link-Test enabled | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3.1.3 | INTEGER {off(0), onGreen(1), blinking(2)} | read-only | current |
| cm10gtLedLK1 OBJECT-TYPE This object identifies the status of the port 1 link (LK1) LED on the media converter module. Possible status values are: off(0) - No link on(1) - Port link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3.1.4 | INTEGER {off(0), on(1)} | read-only | current |
| cm10gtLedLK2 OBJECT-TYPE This object identifies the status of the port 2 link (LK2) LED on the media converter module. Possible status values are: off(0) - No link on(1) - Port link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.10.3.1.5 | INTEGER {off(0), on(1)} | read-only | current |
| cm4gpt OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11 | |||
| cm4gptTable OBJECT-TYPE Table of CM-4GPT type media converter module's status type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1 | not-accessible | current | |
| cm4gptEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-4GPT type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1 | not-accessible | current | |
| cm4gptSlotIndex OBJECT-TYPE The Slot number the CM-4GPT type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.2 | SlotNumber | not-accessible | current |
| cm4gptModelname OBJECT-TYPE This object identifies the model of media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.3 | DisplayString | read-only | current |
| cm4gptModelDesc OBJECT-TYPE This object identifies a static description of the media converter module present in the chassis | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.4 | DisplayString | read-only | current |
| cm4gptHwJmp5ConfigMode OBJECT-TYPE This object identifies the media converter module's ConfigMode, set by hardware jumper J5 on the media converter module. When this object is set to hardwareSwitches(0), the media converter module will disable configuration control from the management module's software and all configuration control comes from the media converter module's hardware switches or jumpers. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.5 | INTEGER {hardwareSwitches(0), auto(1)} | read-only | current |
| cm4gptHwSw1LinkMode OBJECT-TYPE Media converter module's current switch setting for Link Mode. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.6 | INTEGER {swDownSmartLinkPassthrough(0), swUpStandard(1)} | read-only | current |
| cm4gptHwSw2FiberFaultAlert OBJECT-TYPE Media converter module's current switch setting for Fiber Fault Alert. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.7 | INTEGER {swDownDisabled(0), swUpEnabled(1)} | read-only | current |
| cm4gptHwSw3RateSelect OBJECT-TYPE Media converter module's current switch setting for Rate Select. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.8 | INTEGER {swDownLow(0), swUpHigh(1)} | read-only | current |
| cm4gptHwSw4Unused OBJECT-TYPE This object indicates the current switch setting for the 4th, unused switch. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.9 | INTEGER {disabled(0), enabled(1)} | read-only | current |
| cm4gptPort1LinkStatus OBJECT-TYPE Media converter module's current fiber link status (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.10 | INTEGER {down(0), up(1)} | read-only | current |
| cm4gptPort1ConnType OBJECT-TYPE Media converter module's fiber port connector type (port 1). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.11 | INTEGER {sc(0), lc(1), st(2), sfp(3), fc(5), mtrj(6), xfp(7), sfpPlus(8)} | read-only | current |
| cm4gptPort2LinkStatus OBJECT-TYPE Media converter module's current fiber link status (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.12 | INTEGER {down(0), up(1)} | read-only | current |
| cm4gptPort2ConnType OBJECT-TYPE Media converter module's fiber port connector type (port 2). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.1.1.13 | INTEGER {sc(0), lc(1), st(2), sfp(3), fc(5), mtrj(6), xfp(7), sfpPlus(8)} | read-only | current |
| cm4gptConfigTable OBJECT-TYPE Table of CM-4GPT type media converter module's configuration type information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2 | not-accessible | current | |
| cm4gptConfigEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-4GPT type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1 | not-accessible | current | |
| cm4gptConfigSlotIndex OBJECT-TYPE The Slot number the CM-4GPT type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.2 | SlotNumber | not-accessible | current |
| cm4gptConfigStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module, verified and and saved to flash. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.3 | ContainerStatus | read-write | current |
| cm4gptConfigModuleName OBJECT-TYPE This object identifies a user configurable name for the media converter module present in the chassis. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.4 | DisplayString (SIZE(0..63)) | read-write | current |
| cm4gptConfigLinkMode OBJECT-TYPE This object identifies the Link Mode for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.5 | INTEGER {standard(0), smartLinkPassthrough(1)} | read-write | current |
| cm4gptConfigFiberFaultAlert OBJECT-TYPE This object identifies the Fiber Fault Alert setting for the media module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.6 | EnableDisableValue | read-write | current |
| cm4gptConfigRateSelect OBJECT-TYPE This object identifies the Rate Select setting for the media converter module. This object is read-only if the media converter module's ConfigMode jumper is set to hardwareSwitches(0). | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.7 | INTEGER {low(0), high(1)} | read-write | current |
| cm4gptConfigPort1Name OBJECT-TYPE This object identifies a user definable name for port 1. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.8 | DisplayString (SIZE(0..8)) | read-write | current |
| cm4gptConfigPort1Enable OBJECT-TYPE This object identifies whether port 1 is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.9 | YesNoValue | read-write | current |
| cm4gptConfigPort2Name OBJECT-TYPE This object identifies a user definable name for port 2. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.10 | DisplayString (SIZE(0..8)) | read-write | current |
| cm4gptConfigPort2Enable OBJECT-TYPE This object identifies whether port 2 is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.2.1.11 | YesNoValue | read-write | current |
| cm4gptLedTable OBJECT-TYPE Table of CM-4GPT type media converter module's LED status information. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3 | not-accessible | current | |
| cm4gptLedEntry OBJECT-TYPE Entries of the table, each relating to a separate CM-4GPT type media converter module. | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3.1 | not-accessible | current | |
| cm4gptLedsSlotIndex OBJECT-TYPE The Slot number the CM-4GPT type module is currently inserted | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3.1.2 | SlotNumber | not-accessible | current |
| cm4gptLedPWR OBJECT-TYPE This object identifies the status of the power (PWR) LED on the media converter module. Possible status values are: off(0) - No power to the module onGreen(1) - Power being applied to module blinking(2) - Loopback or Link-Test enabled | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3.1.3 | INTEGER {off(0), onGreen(1), blinking(2)} | read-only | current |
| cm4gptLedLK1 OBJECT-TYPE This object identifies the status of the port 1 link (LK1) LED on the media converter module. Possible status values are: off(0) - No link on(1) - Port link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3.1.4 | INTEGER {off(0), on(1)} | read-only | current |
| cm4gptLedLK2 OBJECT-TYPE This object identifies the status of the port 2 link (LK2) LED on the media converter module. Possible status values are: off(0) - No link on(1) - Port link present | 1.3.6.1.4.1.1966.21.1.1.1.1.4.11.3.1.5 | INTEGER {off(0), on(1)} | read-only | current |
| mcrSfpDmiModuleTable OBJECT-TYPE Table of SFP Diagnostic Monitoring Interface information for Optical Transceivers | 1.3.6.1.4.1.1966.21.1.1.1.1.5 | not-accessible | current | |
| mcrSfpDmiModuleEntry OBJECT-TYPE Entries of the table, each relating to a separate SFP module. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1 | not-accessible | current | |
| sfpDmiSlotIndex OBJECT-TYPE The Slot number of the media converter module containing this SFP/XFP | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.2 | SlotNumber | not-accessible | current |
| sfpDmiMediaPortIndex OBJECT-TYPE Media converter module port index. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.3 | Unsigned32 | not-accessible | current |
| sfpDmiStatus OBJECT-TYPE This object identifies the status of the SFP module. If sfpCommFailed bit is set then the rest of the data in this entry is invalid | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.4 | Bits {sfpModuleInserted(24), sfpCommFailed(25), sfpDmiSupported(26)} | read-only | current |
| sfpDmiConnectorType OBJECT-TYPE This object identifies the SFP DMI connector type. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.5 | INTEGER {unknownUnspecified(0), sc(1), fiberChannelStyle1Copper(2), fiberChannelStyle2Copper(3), bncTnc(4), fiberChannelCoaxHeader(5), fiberJack(6), lc(7), mtrj(8), mu(9), sg(10), opticalPigtail(11), hssdcII(32), copperPigtail(33)} | read-only | current |
| sfpDmiNominalBitRate OBJECT-TYPE This object identifies the SFP DMI nominal bit rate of fiber interface, in megabits per second. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.6 | Unsigned32 | read-only | current |
| sfpDmiLinkReach9125 OBJECT-TYPE This object identifies the SFP DMI maximum length in meters of media supported by the fiber transceiver for 9 micron (125 micron jacket) single-mode fiber. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.7 | Integer32 | read-only | current |
| sfpDmiLinkReach50125 OBJECT-TYPE This object identifies the SFP DMI maximum length in meters of media supported by the fiber transceiver for 50 micron (125 micron jacket) multi-mode fiber. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.8 | Integer32 | read-only | current |
| sfpDmiLinkReach625125 OBJECT-TYPE This object identifies the SFP DMI maximum length in meters of media supported by the fiber transceiver for 62.5 micron (125 micron jacket) multi-mode fiber. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.9 | Integer32 | read-only | current |
| sfpDmiFiberWaveLength OBJECT-TYPE This object identifies the wavelength of the fiber interface's optical transceiver, in nanometers. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.10 | Unsigned32 | read-only | current |
| sfpDmiCurrentTempState OBJECT-TYPE This object identifies the current alarm status for SFP DMI internally measured temperature. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.11 | INTEGER {invalid(0), notSupported(1), normal(2), highWarn(3), highAlarm(4), lowWarn(5), lowAlarm(6)} | read-only | current |
| sfpDmiRealTimeTemp OBJECT-TYPE This object identifies the SFP DMI real time temperature. The value displayed will be either Celsius or Fahrenheit based on your current regional display settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.12 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiHighTempWarn OBJECT-TYPE This object identifies the SFP DMI high temperature warning threshold. The value displayed will be either Celsius or Fahrenheit based on your current regional display settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.13 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiHighTempAlarm OBJECT-TYPE This object identifies the SFP DMI high temperature warning threshold. The value displayed will be either Celsius or Fahrenheit based on your current regional display settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.14 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiLowTempWarn OBJECT-TYPE This object identifies the SFP DMI high temperature warning threshold. The value displayed will be either Celsius or Fahrenheit based on your current regional display settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.15 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiLowTempAlarm OBJECT-TYPE This object identifies the SFP DMI high temperature warning threshold. The value displayed will be either Celsius or Fahrenheit based on your current regional display settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.16 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiCurrentVoltState OBJECT-TYPE This object identifies current alarm status for SFP DMI internally measured voltage. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.17 | INTEGER {invalid(0), notSupported(1), normal(2), highWarn(3), highAlarm(4), lowWarn(5), lowAlarm(6)} | read-only | current |
| sfpDmiRealTimeVolt OBJECT-TYPE This object identifies the SFP DMI real time voltage in Volts. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.18 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiHighVoltWarn OBJECT-TYPE This object identifies the SFP DMI high voltage warning threshold in Volts | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.19 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiHighVoltAlarm OBJECT-TYPE This object identifies the SFP DMI high voltage warning threshold in Volts | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.20 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiLowVoltWarn OBJECT-TYPE This object identifies the SFP DMI high voltage warning threshold in Volts | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.21 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiLowVoltAlarm OBJECT-TYPE This object identifies the SFP DMI high voltage warning threshold in Volts | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.22 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiCurrentTxBiasState OBJECT-TYPE This object identifies current alarm status for SFP DMI internally measured transmit bias current in milliamps. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.23 | INTEGER {invalid(0), notSupported(1), normal(2), highWarn(3), highAlarm(4), lowWarn(5), lowAlarm(6)} | read-only | current |
| sfpDmiRealTimeTxBias OBJECT-TYPE This object identifies the SFP DMI high TX Bias current in milliamps. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.24 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiHighTxBiasWarn OBJECT-TYPE This object identifies the SFP DMI high TX Bias current warning threshold in milliamps. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.25 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiHighTxBiasAlarm OBJECT-TYPE This object identifies the SFP DMI high TX Bias current alarm threshold in milliamps. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.26 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiLowTxBiasWarn OBJECT-TYPE This object identifies the SFP DMI low TX Bias current warning threshold in milliamps. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.27 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiLowTxBiasAlarm OBJECT-TYPE This object identifies the SFP DMI low TX Bias current alarm threshold in milliamps. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.28 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiCurrentTxPowerState OBJECT-TYPE This object identifies current alarm status for SFP DMI internally measured transmit power. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.29 | INTEGER {invalid(0), notSupported(1), normal(2), highWarn(3), highAlarm(4), lowWarn(5), lowAlarm(6)} | read-only | current |
| sfpDmiRealTimeTxPower OBJECT-TYPE This object identifies the SFP DMI real time TX output power. The value displayed will be either millwatts or Dbm based on your current regional display settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.30 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiHighTxPowerWarn OBJECT-TYPE This object identifies the SFP DMI high TX output power warning threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.31 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiHighTxPowerAlarm OBJECT-TYPE This object identifies the SFP DMI high TX output power alarm threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.32 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiLowTxPowerWarn OBJECT-TYPE This object identifies the SFP DMI low TX output power warning threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.33 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiLowTxPowerAlarm OBJECT-TYPE This object identifies the SFP DMI low TX output power alarm threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.34 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiCurrentRxPowerState OBJECT-TYPE This object identifies current alarm status for SFP DMI internally measured receive power. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.35 | INTEGER {invalid(0), notSupported(1), normal(2), highWarn(3), highAlarm(4), lowWarn(5), lowAlarm(6)} | read-only | current |
| sfpDmiRealTimeRxPower OBJECT-TYPE This object identifies the SFP DMI real time RX received optical power. The value displayed will be either millwatts or Dbm based on your current regional display settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.36 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiHighRxPowerWarn OBJECT-TYPE This object identifies the SFP DMI high RX received optical warning threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.37 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiHighRxPowerAlarm OBJECT-TYPE This object identifies the SFP DMI high RX received optical alarm threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.38 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiLowRxPowerWarn OBJECT-TYPE This object identifies the SFP DMI low RX received optical warning threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.39 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiLowRxPowerAlarm OBJECT-TYPE This object identifies the SFP DMI low RX received optical alarm threshold. The value displayed will be either millwatts or Dbm based on your current regional display settings. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.40 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiStatus2 OBJECT-TYPE This object identifies the status of the SFP module. If sfpCommFailed value is set then the rest of the data in this entry is invalid 0x80 - sfpModuleInserted 0x40 - sfpCommFailed 0x20 - sfpDmiSupported | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.41 | Unsigned32 | read-only | current |
| sfpDmiVendorSerialNumber OBJECT-TYPE This object identifies the SFP DMI serial number. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.42 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiVendorName OBJECT-TYPE This object identifies the SFP DMI serial number. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.43 | DisplayString (SIZE(0..32)) | read-only | current |
| sfpDmiVendorPartNumber OBJECT-TYPE This object identifies the SFP DMI serial number. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.44 | DisplayString (SIZE(0..32)) | read-only | current |
| xfpDmiAux1Type OBJECT-TYPE This object identifies the type of value that is being measured by the Auxillary 1 registers on the XFP | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.45 | INTEGER {notSupported(0), apdBiasVoltmv(1), tecCurrentma(3), laserTemperature(4), laserWavelength(5), p5Voltv(6), p33Voltv(7), p18Voltv(8), m52Voltv(9), p5vCurrentma(10), p33vCurrentma(13), p18vCurrentma(14), m52vCurrentma(15)} | read-only | current |
| xfpDmiAux1State OBJECT-TYPE This object identifies current alarm status for the XFP Aux1 registers | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.46 | INTEGER {invalid(0), notSupported(1), normal(2), highWarn(3), highAlarm(4), lowWarn(5), lowAlarm(6)} | read-only | current |
| xfpDmiRealTimeAux1 OBJECT-TYPE This object identifies the XFP DMI real time values for the Aux1 registers | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.47 | DisplayString (SIZE(0..32)) | read-only | current |
| xfpDmiHighAux1Warn OBJECT-TYPE This object identifies the XFP DMI high warning threshold for Aux1 | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.48 | DisplayString (SIZE(0..32)) | read-only | current |
| xfpDmiHighAux1Alarm OBJECT-TYPE This object identifies the XFP DMI alarm alarm threshold for Aux1 | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.49 | DisplayString (SIZE(0..32)) | read-only | current |
| xfpDmiLowAux1Warn OBJECT-TYPE This object identifies the XFP DMI low warning threshold for Aux1 | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.50 | DisplayString (SIZE(0..32)) | read-only | current |
| xfpDmiLowAux1Alarm OBJECT-TYPE This object identifies the XFP DMI low alarm threshold for Aux1 | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.51 | DisplayString (SIZE(0..32)) | read-only | current |
| xfpDmiAux2Type OBJECT-TYPE This object identifies the type of value that is being measured by the Auxillary 1 registers on the XFP | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.52 | INTEGER {notSupported(0), apdBiasVoltmv(1), tecCurrentma(3), laserTemperature(4), laserWavelength(5), p5Voltv(6), p33Voltv(7), p18Voltv(8), m52Voltv(9), p5vCurrentma(10), p33vCurrentma(13), p18vCurrentma(14), m52vCurrentma(15)} | read-only | current |
| xfpDmiAux2State OBJECT-TYPE This object identifies current alarm status for the XFP Aux2 registers | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.53 | INTEGER {invalid(0), notSupported(1), normal(2), highWarn(3), highAlarm(4), lowWarn(5), lowAlarm(6)} | read-only | current |
| xfpDmiRealTimeAux2 OBJECT-TYPE This object identifies the SFP DMI real time values for the Aux2 registers | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.54 | DisplayString (SIZE(0..32)) | read-only | current |
| xfpDmiHighAux2Warn OBJECT-TYPE This object identifies the XFP DMI high warning threshold for Aux2 | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.55 | DisplayString (SIZE(0..32)) | read-only | current |
| xfpDmiHighAux2Alarm OBJECT-TYPE This object identifies the XFP DMI alarm alarm threshold for Aux2 | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.56 | DisplayString (SIZE(0..32)) | read-only | current |
| xfpDmiLowAux2Warn OBJECT-TYPE This object identifies the XFP DMI low warning threshold for Aux2 | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.57 | DisplayString (SIZE(0..32)) | read-only | current |
| xfpDmiLowAux2Alarm OBJECT-TYPE This object identifies the XFP DMI low alarm threshold for Aux2 | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.58 | DisplayString (SIZE(0..32)) | read-only | current |
| xfpDmiMinBitRate OBJECT-TYPE This object specifies the XFP minimum bit rate. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.59 | Integer32 | read-only | current |
| xfpDmiMaxBitRate OBJECT-TYPE This object specifies the XFP maximum bit rate. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.60 | Integer32 | read-only | current |
| xfpDmiReachEBW50125 OBJECT-TYPE This object specifies the link length that is supported by the fiber transceiver using extended bandwidth 50 micron core (125 micron jacket) multimode fiber | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.61 | Integer32 | read-only | current |
| sfpDmiReachCopper OBJECT-TYPE This object identifies the maximum length in meters that is supported by the SFP/XFP interface using copper cable. | 1.3.6.1.4.1.1966.21.1.1.1.1.5.1.62 | Integer32 | read-only | current |
| mcrAlarmsWarningsTable OBJECT-TYPE Table of outstanding alarms and warnings. | 1.3.6.1.4.1.1966.21.1.1.1.1.6 | not-accessible | current | |
| mcrAlarmsWarningsEntry OBJECT-TYPE Entries of the table, each relating to a separate alarm or warning. | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1 | not-accessible | current | |
| alarmWarnSequenceIndex OBJECT-TYPE This object identifies the sequence in which the alarms or warnings were generated. Gaps in the sequence numbers are normal. | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.2 | Unsigned32 | not-accessible | current |
| alarmWarnType OBJECT-TYPE This object identifies the alert/Trap number associated with this alarm/warning. | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.3 | Unsigned32 | read-only | current |
| alarmWarnSeverity OBJECT-TYPE This object identifies the severity level of the alarm/warning. Value will be one of the top three levels. | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.4 | Unsigned32 | read-only | current |
| alarmWarnFlags OBJECT-TYPE This object identifies the flags defining the alarm/warning. 0x00000002 - chassis type alert 0x00000004 - Power Supply Monitoring Unit type alert 0x00000008 - PSMU power supply type alert 0x00000010 - PSMU fan type alert 0x00000020 - Management module type alert 0x00000040 - Media converter module type alert 0x00000080 - Media converter module SFP module type alert. | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.5 | Unsigned32 | read-only | current |
| alarmWarnChassisNum OBJECT-TYPE This object identifies the chassis number associated with this alarm/warning. | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.6 | Unsigned32 | read-only | current |
| alarmWarnDeviceNum OBJECT-TYPE This object identifies the Hardware slot/bay location of the hardware associated with this alarm or warning. - 0 indicates alarm/warning occurred on the chassis backplane. - If AlarmWarnFlags indicates a power supply then this value the power supply bay number. - Otherwise it is the chassis slot number. | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.7 | Unsigned32 | read-only | current |
| alarmWarnTimeStamp OBJECT-TYPE This object identifies the time stamp of when the alarm/warning was reported. (in seconds since the Epoch, defined as 0:00:00 UTC on the morning of January 1, 1970), that the alert was reported on the MCR-MGT.) | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.8 | TimeTicks | read-only | current |
| alarmWarnMessage OBJECT-TYPE This object identifies the alarm/warning message string which will contain any values of bound variables. | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.9 | DisplayString | read-only | current |
| alarmWarnPortNum OBJECT-TYPE This object identifies the location of the media port associated with this alarm or warning. | 1.3.6.1.4.1.1966.21.1.1.1.1.6.1.10 | Unsigned32 | read-only | current |
| mcrMediaPortTable OBJECT-TYPE Table of general port status information. | 1.3.6.1.4.1.1966.21.1.1.1.1.7 | not-accessible | current | |
| mcrMediaPortEntry OBJECT-TYPE Entries of the table, each relating to a separate media converter module port. | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1 | not-accessible | current | |
| mediaPortSlotIndex OBJECT-TYPE Slot number for the media converter module containing this port. | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.2 | Unsigned32 | not-accessible | current |
| mediaPortPortIndex OBJECT-TYPE Port number on media card. Valid values are 1 to the highest number of ports available on a media card. There are usually two ports | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.3 | Unsigned32 | not-accessible | current |
| moduleModel OBJECT-TYPE This object identifies the model name of the module containing this port. | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.4 | DisplayString | read-only | current |
| portName OBJECT-TYPE This object identifies the name configured for this port. | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.5 | DisplayString | read-only | current |
| portEnable OBJECT-TYPE This object indicates whether the port has been enabled. | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.6 | INTEGER {disabled(0), enable(1)} | read-only | current |
| portType OBJECT-TYPE The type of port (copper, fiber, etc.) . | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.7 | INTEGER {copper(0), fiber(1), sfp(2), xfp(3), sfpPlus(4)} | read-only | current |
| portLinkStatus OBJECT-TYPE The port's current link status. | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.8 | INTEGER {down(0), up(1), shutdown(2)} | read-only | current |
| portConnType OBJECT-TYPE The port's connector type | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.9 | INTEGER {rj45(0), sc(1), lc(2), st(3), sfp(4), fc(5), mtrj(6), xfp(7), sfpPlus(8)} | read-only | current |
| portAutoNegState OBJECT-TYPE The port's auto-negotiation state | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.10 | INTEGER {notApplicable(-1), disabled(0), complete(1), inProgress(2)} | read-only | current |
| portSpeed OBJECT-TYPE If the port auto-negotiation state is complete then this object indicates the ports current auto-negotiated speed setting. If auto-negotiation is not complete then the value returned should be ignored | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.11 | INTEGER {notApplicable(-1), speed10Mbs(0), speed100Mbps(1), speed1000Mbps(2), speed10Gbps(3)} | read-only | current |
| portDuplex OBJECT-TYPE If port auto-negotiation state is complete then this object indicates the media converter module's current auto-negotiated duplex setting for this port. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.12 | INTEGER {notApplicable(-1), half(0), full(1)} | read-only | current |
| portPause OBJECT-TYPE If port auto-negotiation state is complete then this object indicates the media converter module's current auto-negotiated pause setting for this port. If auto-negotiation is not complete then the value returned should be ignored. | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.13 | INTEGER {notApplicable(-1), disabled(0), symmetrical(1), asymmetricalTx(2), asymmetricalRx(3)} | read-only | current |
| portRemoteStatus OBJECT-TYPE This port's Link Partner Remote Fault status or Far End Fault status | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.14 | INTEGER {notApplicable(-1), ok(0), remoteFault(1), offline(2), linkFault(3), autoNegError(4), disable(5), receivingFEF(6), sendingFEF(7)} | read-only | current |
| portMediaType OBJECT-TYPE The type of port (copper, fiber, etc.) . | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.15 | INTEGER {unknown(-1), copper(0), fiber(1)} | read-only | current |
| portPhysicalProtocol OBJECT-TYPE The physical networking protocol used by the port. | 1.3.6.1.4.1.1966.21.1.1.1.1.7.1.16 | INTEGER {unknown(0), ethernet(1), vdsl(2)} | read-only | current |
| mcrManagementGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2 | |||
| mgtNetworkGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.1 | |||
| systemGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1 | |||
| systemStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.1 | ContainerStatus | read-write | current |
| systemName OBJECT-TYPE The name of the system management module. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.2 | DisplayString (SIZE(1..63)) | read-write | current |
| systemDomainName OBJECT-TYPE The domain name of the management module. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.3 | DisplayString (SIZE(0..32)) | read-write | current |
| systemIpAddress OBJECT-TYPE The management module's unique IPv4 network IP address. If you are using the management module in an IPv6 network, this field can be left blank. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.4 | IpAddress | read-write | current |
| systemSubnetBits OBJECT-TYPE The number of bits in the subnet mask. For example, a subnet mask of 255.255.0.0 has 16 subnet/prefix bits. Valid values are 0-32. The default is 0. When the value is 0, the correct value is determined based on the class of the IP Address. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.5 | Integer32 (0..32) | read-write | current |
| systemDHCPUpdateDNS OBJECT-TYPE If enabled, the DNS system will be updated after the management module gets the IP address via DHCP. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.6 | OnOffValue | read-write | current |
| systemAutoObtainDNS OBJECT-TYPE If on, the DNS server IP address will be obtained automatically automatically via DHCP. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.7 | OnOffValue | read-write | current |
| systemAutoObtainGW OBJECT-TYPE If enabled, the default gateway IP address will be get automatically via DHCP. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.8 | OnOffValue | read-write | current |
| systemDomainPrefix OBJECT-TYPE The domain prefix for primary Ethernet interface of the management module. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.9 | DisplayString (SIZE(0..7)) | read-write | current |
| systemTFTPRetry OBJECT-TYPE The number of times the management module will attempt to transfer (using TFTP) a file to/from a host. Default is 5. A value of 0 (zero) means that the management module will not attempt a retry should TFTP fail. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.10 | Integer32 (0..5) | read-write | current |
| systemTFTPTimeOut OBJECT-TYPE The time, in seconds, that the management module will wait for a successful transmit or receipt of TFTP packets before retrying a TFTP transfer. Default is 3 seconds. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.1.11 | Integer32 (3..10) | read-write | current |
| gatewayTable OBJECT-TYPE Table of configured gateway. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2 | not-accessible | current | |
| gatewayEntry OBJECT-TYPE Entries of the table, each relating to a separate configured gateway. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1 | not-accessible | current | |
| gatewayIndex OBJECT-TYPE gatewayIndex | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.1 | GenericTableIndex | not-accessible | current |
| gatewayStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.2 | ContainerStatus | read-write | current |
| gatewayHost OBJECT-TYPE You can specify up to twenty hosts to act as gateways in your network. Each gateway host must be defined in the management module host table. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.3 | DisplayString (SIZE(0..14)) | read-write | current |
| gatewayType OBJECT-TYPE Specify the type of gateway: Default-A gateway which provides general access beyond your local network. Host-A gateway reserved for accessing a specific host external to your local network. Network-A gateway reserved for accessing a specific network external to your local network. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.4 | INTEGER {host(0), network(1), default(2)} | read-write | current |
| gatewayIpAddress OBJECT-TYPE When the gateway is a Host or Network gateway, you must specify the IP address of the target host machine/network. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.5 | Ipv4v6Address | read-write | current |
| gatewaySubnetBits OBJECT-TYPE When the gateway is a Network gateway, you must specify the subnet/prefix bits for that network. If the IP address is IPv4, then the Subnet/Prefix Bits range is 0-32. If the IP address is IPv6, then the Subnet/Prefix Bits range is 0-128. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.6 | Integer32 (0..128) | read-write | current |
| gatewayInterface OBJECT-TYPE The interface that the management module is going to use to access the Remote Host. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.2.1.7 | DisplayString (SIZE(0..20)) | read-write | current |
| hostTable OBJECT-TYPE The hosts Group table. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.3 | not-accessible | current | |
| hostEntry OBJECT-TYPE An entry in the host table, each relating to a separate host. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1 | not-accessible | current | |
| hostIndex OBJECT-TYPE The table entry number for this host. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1.1 | GenericTableIndex | not-accessible | current |
| hostStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1.2 | ContainerStatus | read-write | current |
| hostName OBJECT-TYPE The host name used for this host entry. To delete an entry, blank out this field. If blank, this entry is currently unused. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1.3 | DisplayString (SIZE(0..14)) | read-write | current |
| hostIpAddr OBJECT-TYPE The host IP address used for this entry. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1.4 | Ipv4v6Address | read-write | current |
| hostFqdn OBJECT-TYPE The host full qualified domain name for the host entry. If blank, this entry is currently unused. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.3.1.5 | DisplayString (SIZE(0..255)) | read-write | current |
| dnsTable OBJECT-TYPE Table of DNS hosts | 1.3.6.1.4.1.1966.21.1.1.1.2.1.4 | not-accessible | current | |
| dnsEntry OBJECT-TYPE Entries of the table, each relating to a separate DNS host. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.4.1 | not-accessible | current | |
| dnsIndex OBJECT-TYPE DNS host index | 1.3.6.1.4.1.1966.21.1.1.1.2.1.4.1.1 | GenericTableIndex | not-accessible | current |
| dnsStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.4.1.2 | ContainerStatus | read-write | current |
| dnsIpAddress OBJECT-TYPE You can specify the IP addresses for up to two DNS (Domain Name Servers) hosts in your network. The first DNS entry in the list is the primary DNS and the second DNS entry is the secondary server. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.4.1.3 | Ipv4v6Address | read-write | current |
| dnsActive OBJECT-TYPE Activates/deactivates a DNS entry. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.4.1.4 | OnOffValue | read-write | current |
| dynamicDNSGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5 | |||
| dynamicDNSStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.1 | ContainerStatus | read-write | current |
| dynamicDNS OBJECT-TYPE Enable/disable dynamic DNS. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.2 | OnOffValue | read-write | current |
| dynamicDNSHostname OBJECT-TYPE Host name. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.3 | DisplayString (SIZE(1..14)) | read-write | current |
| dynamicDNSUserName OBJECT-TYPE User name. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.4 | DisplayString (SIZE(1..16)) | read-write | current |
| dynamicDNSPassword OBJECT-TYPE This object identifies the dynamic DNS password. Reading of this object will always return a blank string | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.5 | DisplayString (SIZE(1..16)) | read-write | current |
| dynamicDNSSystemType OBJECT-TYPE System type. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.6 | INTEGER {dynamic(0), static(1), custom(2)} | read-write | current |
| dynamicDNSWildCard OBJECT-TYPE Specifies whether to add a alias such as * to your registered host name. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.7 | INTEGER {enable(0), disable(1), nochange(2)} | read-write | current |
| dynamicDNSConnectionMethod OBJECT-TYPE Specifies how the management module is going to connection to the DynDNS.org server. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.8 | INTEGER {http(0), httpport8245(1), https(2)} | read-write | current |
| dynamicDNSSSLVerifyPeerCertificate OBJECT-TYPE Enable this option when you want the Validation Criteria to match the Peer Certificate for authentication to pass. If you enable this option, you need to download an SSL/TLS certificate authority (CA) list file to the management module. Any values that are entered in the validation criteria must match the peer certificate for an SSL connection; any fields left blank will not be validated against the peer certificate. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.9 | OnOffValue | read-write | current |
| dynamicDNSSSLCountry OBJECT-TYPE A two character country code; for example, US. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.10 | DisplayString (SIZE(0..2)) | read-write | current |
| dynamicDNSSSLStateProv OBJECT-TYPE Up to a 128 character entry for the state/province; for example, IL. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.11 | DisplayString (SIZE(0..128)) | read-write | current |
| dynamicDNSSSLLocality OBJECT-TYPE Up to a 128 character entry for the location; for example, a city. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.12 | DisplayString (SIZE(0..128)) | read-write | current |
| dynamicDNSSSLOrganisation OBJECT-TYPE Up to a 64 character entry for the organization; for example, Accounting. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.13 | DisplayString (SIZE(0..64)) | read-write | current |
| dynamicDNSSSLOrganisationUnit OBJECT-TYPE Up to a 64 character entry for the unit in the organization; for example, Payroll. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.14 | DisplayString (SIZE(0..64)) | read-write | current |
| dynamicDNSSSLCommonName OBJECT-TYPE Up to a 64 character entry for common name; for example, the host name or fully qualified domain name. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.15 | DisplayString (SIZE(0..64)) | read-write | current |
| dynamicDNSSSLEmail OBJECT-TYPE Up to a 64 character entry for an email address; for example, acct@anycompany.com. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.16 | DisplayString (SIZE(0..128)) | read-write | current |
| dynamicDNSStatusString OBJECT-TYPE Dynamic DNS statistics | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.17 | OCTET STRING (SIZE(0..1024)) | read-only | current |
| dynamicDNSSSLCipherTable OBJECT-TYPE SSL Cipher. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18 | not-accessible | current | |
| dynamicDNSSSLCipherEntry OBJECT-TYPE An entry in the dynamicDNSSSLCipherTable, each relating to a cipher entry. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1 | not-accessible | current | |
| dynamicDNSSSLCipherPriority OBJECT-TYPE The cipher priority. 1- highest 5 - lowest. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.1 | Integer32 (1..5) | not-accessible | current |
| dynamicDNSSSLCipherStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.2 | ContainerStatus | read-write | current |
| dynamicDNSSSLCipherEncryption OBJECT-TYPE SSL Encryption. None is not allowed for priority 1. Any will use the first encryption format that can be negotiated. The default is any. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.3 | INTEGER {none(0), any(1), aes(2), tripledes(3), des(4), arctwo(5), arcfour(6)} | read-write | current |
| dynamicDNSSSLCipherKeySizeMin OBJECT-TYPE The minimum key size value that will be used for the specified encryption type. The default is 40. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.4 | INTEGER {min40(0), min56(1), min64(2), min128(3), min168(4), min256(5)} | read-write | current |
| dynamicDNSSSLCipherKeySizeMax OBJECT-TYPE The maximum key size value that will be used for the specified encryption type. The default is 256. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.5 | INTEGER {max40(0), max56(1), max64(2), max128(3), max168(4), max256(5)} | read-write | current |
| dynamicDNSSSLCipherKeyExchange OBJECT-TYPE The type of key to exchange for the encryption format: Any-Any key exchange that is valid is used (this does not, however, include ADH keys). RSA-This is an RSA key exchange using an RSA key and certificate. EDHRSA-This is an EDH key exchange using an RSA key and certificate. EDHDSS-This is an EDH key exchange using a DSA key and certificate. ADH-This is an anonymous key exchange which does not require a private key or certificate. Choose this key if you do not want to authenticate the peer device, but you want the data encrypted on the SSL/TLS connection. The default is Any. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.6 | INTEGER {any(0), rsa(1), edhrsa(2), edhdss(3), adh(4)} | read-write | current |
| dynamicDNSSSLCipherHMAC OBJECT-TYPE Select the key-hashing for message authentication method for your encryption type: Any, MD5, or SHA1. The default is Any. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.5.18.1.7 | INTEGER {any(0), sha(1), md5(2)} | read-write | current |
| ipv6Group OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6 | |||
| ipv6ServicesGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1 | |||
| ipv6serviceStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.1 | ContainerStatus | read-write | current |
| serviceAutoDiscovery OBJECT-TYPE When on, the management module will send out a Router Solicitation message. If a Router Advertisement message is received, the management module will configure the IPv6 address(es) and configuration parameters based on the information contained in the advertisement. If no Router Advertisement message is received, the management module will attempt to connect to a DHCPv6 server to obtain IPv6 addresses and other configuration parameters. Default on. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.2 | OnOffValue | read-write | current |
| serviceDHCPv6 OBJECT-TYPE When on, requests IPv6 address(es) and configuration information from the DHCPv6 server. Default off. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.3 | OnOffValue | read-write | current |
| serviceDHCPv6IPAddresses OBJECT-TYPE When on, the management module will accept IPv6 address(es) from the DHCPv6 server. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.4 | OnOffValue | read-write | current |
| serviceDHCPv6NetworkPrefix OBJECT-TYPE When on, the management module will accept the network prefix from the DHCPv6 server. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.5 | OnOffValue | read-write | current |
| serviceDHCPv6AutoObtainDNS OBJECT-TYPE If on, the DNS server IP address will be obtained automatically automatically via DHCP. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.1.6 | OnOffValue | read-write | current |
| ipv6AddressTable OBJECT-TYPE IPv6 custom address table. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2 | not-accessible | current | |
| ipv6AddressEntry OBJECT-TYPE IPv6 custom entry. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1 | not-accessible | current | |
| ipv6AddressIndex OBJECT-TYPE Custom IPv6 address index. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.1 | GenericTableIndex | not-accessible | current |
| ipv6AddressStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.2 | ContainerStatus | read-write | current |
| ipv6AddressAddr OBJECT-TYPE Either enter a network prefix that the Device Server will use to derive an IPv6 address using the Device Server's MAC address (must turn ipv6AddressAuto1 on) or enter a specific IPv6 address. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.3 | Ipv4v6Address | read-write | current |
| ipv6AddressPrefixBits OBJECT-TYPE The IPv6 prefix bits of either the network or IPv6 address. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.4 | Integer32 (0..128) | read-write | current |
| ipv6AddressAuto OBJECT-TYPE When on, the management module will derive an IPv6 address from the entered network prefix and the management module's MAC address. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.5 | OnOffValue | read-write | current |
| ipv6AddressSendAdvertise OBJECT-TYPE When on, the management module will include the IPv6 address in router advertisements. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.2.1.6 | OnOffValue | read-write | current |
| interfacev6StatsTable OBJECT-TYPE The interface IPv6 Group table. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3 | not-accessible | current | |
| interfacev6StatsEntry OBJECT-TYPE An entry in the interface IPv6 table | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1 | not-accessible | current | |
| interfacev6Index OBJECT-TYPE The IPv6 interface index. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1.1 | GenericTableIndex | not-accessible | current |
| interfacev6Name OBJECT-TYPE The IPv6 interface name. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1.2 | DisplayString | read-only | current |
| interfacev6Address OBJECT-TYPE The IPv6 interface IP address. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1.3 | DisplayString | read-only | current |
| interfacev6PrefixBits OBJECT-TYPE The IPv6 interface Prefix bits | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1.4 | Integer32 (0..128) | read-only | current |
| interfacev6Scope OBJECT-TYPE The IPv6 interface scope. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.3.1.5 | INTEGER {global(0), host(1), link(2), site(3), compatv4(4), unknown(5)} | read-only | current |
| ipv6TunnelTable OBJECT-TYPE IPv6 tunnel table. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4 | not-accessible | current | |
| ipv6TunnelEntry OBJECT-TYPE IPv6 tunnel entry. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1 | not-accessible | current | |
| ipv6TunnelIndex OBJECT-TYPE The IPv6 tunnel index. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1.1 | GenericTableIndex | not-accessible | current |
| ipv6TunnelStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1.2 | ContainerStatus | read-write | current |
| ipv6TunnelName OBJECT-TYPE The name of the IPv6 tunnel. Maximum 16 alphanumeric characters. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1.3 | DisplayString | read-write | current |
| ipv6TunnelMode OBJECT-TYPE The method or protocol that is used to create the IPv6 tunnel. o Manual-When specified, the management module will manually create the IPv6 tunnel to the specified Remote Host through the specified Interface. o ip6to4-When specified, the MCR-MGT will broadcast to the multicast address 192.88.99.1 through the specified Interface. When the closest ip6to4 router responds, it will create the IPv6 tunnel, encapsulating and decapsulating IPv6 traffic sent to and from the management module. o Teredo-When specified, the Teredo protocol encapsulates the IPv6 packet as an IPv4 UDP message, allowing it to pass through most network address translator (NAT) boxes and create an IPv6 tunnel to the specified Remote Host (a Teredo server) through the specified Interface. Default is Manual. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1.4 | INTEGER {manual(0), ip6to4(1), teredo(2)} | read-write | current |
| ipv6TunnelRemoteHost OBJECT-TYPE The IPv4 host that can access the IPv6 network when the Mode is Manual. The Teredo server when the Mode is Teredo. | 1.3.6.1.4.1.1966.21.1.1.1.2.1.6.4.1.5 | DisplayString | read-write | current |
| mgtAccessGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.2 | |||
| mgtAcessServicesGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1 | |||
| accessServicesStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.1 | ContainerStatus | read-write | current |
| accessServicesSessInactTimeout OBJECT-TYPE The amount of time, in seconds, that the management session inactivity timer will run. When the timer expires, becuase no activity on the management session within the specified time, the management module will reset the management session. A value of 0 (zero), means that the inactivity timer will not expire (the session is open permanently, or until the user logs out). | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.2 | Integer32 (0..4294967) | read-write | current |
| accessServiceHTTPD OBJECT-TYPE Turn on/off the HTTPD Service | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.3 | OnOffValue | read-write | current |
| accessServiceHTTPSD OBJECT-TYPE Turn on/off the HTTPSD Service | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.4 | OnOffValue | read-write | current |
| accessServiceTelnetD OBJECT-TYPE Turn on/off the TelnetD Service | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.5 | OnOffValue | read-write | current |
| acessServiceSSHD OBJECT-TYPE Turn on/off the SSHD Service | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.6 | OnOffValue | read-write | current |
| acessServiceSnmpD OBJECT-TYPE Turn on/off the SnmpD Service | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.7 | OnOffValue | read-write | current |
| acessServiceSetIP OBJECT-TYPE Turn on/off the SetIP Service | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.8 | OnOffValue | read-write | current |
| acessIncomingPings OBJECT-TYPE Allow incoming ping requests. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.1.9 | EnableDisableValue | read-write | current |
| webManagerGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.2.2 | |||
| webManagerStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.2.1 | ContainerStatus | read-write | current |
| httpsPassphrase OBJECT-TYPE This object identifies the HTTPS SSL certificate passphrase. Reading of this object will always return a blank string | 1.3.6.1.4.1.1966.21.1.1.1.2.2.2.2 | DisplayString (SIZE(1..16)) | read-write | current |
| sshServerGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3 | |||
| sshServerStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.1 | ContainerStatus | read-write | current |
| sshServerAuthRSA OBJECT-TYPE When a client SSH session requests RSA authentication, the management module's SSH server will authenticate the user via RSA. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.2 | OnOffValue | read-write | current |
| sshServerAuthDSA OBJECT-TYPE When a client SSH session requests DSA authentication, the management module's SSH server will authenticate the user via DSA | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.3 | OnOffValue | read-write | current |
| sshServerAuthKeyboard OBJECT-TYPE The user types in a password for authentication. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.4 | OnOffValue | read-write | current |
| sshServerAuthPassword OBJECT-TYPE The user types in a password for authentication. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.5 | OnOffValue | read-write | current |
| sshServerCipher3Des OBJECT-TYPE The management module SSH server's 3DES encryption is enable/disabled. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.6 | OnOffValue | read-write | current |
| sshServerCipherBlowfish OBJECT-TYPE The management module SSH server's Blowfish encryption is enabled/disabled. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.7 | OnOffValue | read-write | current |
| sshServerCipherCipherAES OBJECT-TYPE The management module SSH server's AES encryption is enabled/disabled | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.8 | OnOffValue | read-write | current |
| sshServerCipherCAST OBJECT-TYPE The management module SSH server's CAST encryption is enabled/disabled | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.9 | OnOffValue | read-write | current |
| sshServerCipherArcfour OBJECT-TYPE The management module SSH server's Arcfour encryption is enabled/disabled. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.10 | OnOffValue | read-write | current |
| sshServerVerbose OBJECT-TYPE Displays debug messages on the terminal. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.11 | OnOffValue | read-write | current |
| sshServerCompression OBJECT-TYPE Requests compression of all data. Compression is desirable on slow connections, but will only slow down things on fast networks. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.12 | OnOffValue | read-write | current |
| sshServerSSH1 OBJECT-TYPE Enable/Disable SSH-1 on the server. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.3.13 | OnOffValue | read-write | current |
| snmpAgentGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4 | |||
| snmpAgentStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.1 | ContainerStatus | read-write | current |
| snmpContact OBJECT-TYPE The name and contract information of the person who manages this SMNP node. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.2 | DisplayString (SIZE(0..14)) | read-write | current |
| snmpLocation OBJECT-TYPE The physical location of the SNMP node. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.3 | DisplayString (SIZE(0..32)) | read-write | current |
| snmpCommunityTable OBJECT-TYPE Table of SNMP communities configured for the MCR-MGT agent | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4 | not-accessible | current | |
| snmpCommunityEntry OBJECT-TYPE Entries of the table, each relating to a separate SNMP community definition | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1 | not-accessible | current | |
| snmpCommunityIndex OBJECT-TYPE The MCR-MGT agent community index | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1.1 | GenericTableIndex | not-accessible | current |
| snmpCommunityStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1.2 | ContainerStatus | read-write | current |
| snmpCommunityName OBJECT-TYPE A name that will be sent to the management module from an SNMP manager. This name will define the permissions of the manager. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1.3 | DisplayString (SIZE(0..14)) | read-write | current |
| snmpCommunityIpAddress OBJECT-TYPE The IP address of the SNMP manager that will send requests to the management module. If the address is 0.0.0.0, any SNMP manager with the Community Name can access the management module. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1.4 | Ipv4v6Address | read-write | current |
| snmpCommunityPermission OBJECT-TYPE Permits the management module to respond to SNMP requests by: None -There is no response to requests from SNMP. Readonly -Responds only to Read requests from SNMP. Readwrite -Responds to both Read and Write requests from SNMP. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.4.1.5 | INTEGER {none(0), readonly(1), readwrite(2)} | read-write | current |
| snmpV3ReadOnlyUser OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5 | |||
| snmpV3ReadOnlyStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.1 | ContainerStatus | read-write | current |
| snmpV3ReadOnlyUserName OBJECT-TYPE SNMP v3 read-only user name. This SNMP v3 user will have read-only S SNMP access permissions. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.2 | DisplayString (SIZE(0..16)) | read-write | current |
| snmpV3ReadOnlySecurityLevel OBJECT-TYPE Specifies the SNMP v3 read-only user security level. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.3 | INTEGER {none(0), authNoPriv(1), authPriv(2)} | read-write | current |
| snmpV3ReadOnlyAuthAlgorithm OBJECT-TYPE Specifies the SNMP v3 read-only user authentication method. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.4 | INTEGER {md5(0), sha(1)} | read-write | current |
| snmpV3ReadOnlyAuthPasswd OBJECT-TYPE Specifies the SNMP v3 read-only user authentication password. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.5 | DisplayString (SIZE(0..128)) | read-write | current |
| snmpV3ReadOnlyPrivacyAlgorithm OBJECT-TYPE Specifies the SNMP v3 read-only user privacy algorithm. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.6 | INTEGER {des(0), aes(1)} | read-write | current |
| snmpV3ReadOnlyPrivacyPasswd OBJECT-TYPE Specifies the SNMP v3 read-only user privacy password. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.5.7 | DisplayString (SIZE(0..128)) | read-write | current |
| snmpV3ReadWriteUser OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6 | |||
| snmpV3ReadWriteStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.1 | ContainerStatus | read-write | current |
| snmpV3ReadWriteUserName OBJECT-TYPE Specifies the SNMP v3 read-write user name. This SNMP v3 user will have read-write SNMP access permissions. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.2 | DisplayString (SIZE(0..16)) | read-write | current |
| snmpV3ReadWriteSecurityLevel OBJECT-TYPE Specifies the SNMP v3 read-write user security level. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.3 | INTEGER {none(0), authNoPriv(1), authPriv(2)} | read-write | current |
| snmpV3ReadWriteAuthAlgorithm OBJECT-TYPE Specifies the SNMP v3 read-write user authentication method. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.4 | INTEGER {md5(0), sha(1)} | read-write | current |
| snmpV3ReadWriteAuthPasswd OBJECT-TYPE Specifies the SNMP v3 read-write user authentication password. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.5 | DisplayString (SIZE(0..128)) | read-write | current |
| snmpV3ReadWritePrivacyAlgorithm OBJECT-TYPE Specifies the SNMP v3 read-write user privacy algorithm. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.6 | INTEGER {des(0), aes(1)} | read-write | current |
| snmpV3ReadWritePrivacyPasswd OBJECT-TYPE Specifies the SNMP v3 read-write user privacy password. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.4.6.7 | DisplayString (SIZE(0..128)) | read-write | current |
| authorizedHostGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5 | |||
| authHostsStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.1 | ContainerStatus | read-write | current |
| authHostOnly OBJECT-TYPE Determines whether only authorized hosts are allowed to access the management module. If set to yes then the management module will only respond to, and allow access to and from, the IP or MAC addresses of hosts configured in the authorized IP and MAC hosts tables. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.2 | YesNoValue | read-write | current |
| authIpHostTable OBJECT-TYPE The hosts Group table. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3 | not-accessible | current | |
| authIpHostEntry OBJECT-TYPE An entry in the AuthIpHostTable, each relating to a IP host. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3.1 | not-accessible | current | |
| authHostIpIndex OBJECT-TYPE The table entry number for this host. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3.1.1 | GenericTableIndex | not-accessible | current |
| authHostIpStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3.1.2 | ContainerStatus | read-write | current |
| authHostIpAddr OBJECT-TYPE The host IP address used for this entry. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3.1.3 | Ipv4v6Address | read-write | current |
| authHostIpDescr OBJECT-TYPE The host IP entry description. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.3.1.4 | DisplayString (SIZE(0..21)) | read-write | current |
| authMacHostTable OBJECT-TYPE The hosts Group table. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4 | not-accessible | current | |
| authMacHostEntry OBJECT-TYPE An entry in the AuthIpHostTable, each relating to a host. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4.1 | not-accessible | current | |
| authHostMacIndex OBJECT-TYPE The table entry number for this host. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4.1.1 | GenericTableIndex | not-accessible | current |
| authHostMacStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4.1.2 | ContainerStatus | read-write | current |
| authHostMacAddr OBJECT-TYPE The host MAC address used for this entry. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4.1.3 | MacAddress | read-write | current |
| authHostMacDescr OBJECT-TYPE The host MAC address entry description. | 1.3.6.1.4.1.1966.21.1.1.1.2.2.5.4.1.4 | DisplayString (SIZE(0..21)) | read-write | current |
| mgtAlertGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.3 | |||
| alertLocalEventGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.3.1 | |||
| localEventLogStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.1.1 | ContainerStatus | read-write | current |
| localEventLogEnabled OBJECT-TYPE Determines whether alert events are logged to the internal local event log. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.1.2 | YesNoValue | read-write | current |
| localEventLogAlertLevel OBJECT-TYPE Choose the alert level that will trigger a local event being stored in the local event log. When you select an alert level, all alerts that appear above it in the list will also trigger a local event log message. For example, if you select oneTimeError, all oneTimeError, persistantError, moduleLevelFault, and systemLevelFault alert events will be generate a local event message. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.1.3 | AlertSeverityLevel | read-write | current |
| localEventLogClear OBJECT-TYPE Writing a yes(1) to this object will clear the local event log on the management module. Reading of this object will always return 0 | 1.3.6.1.4.1.1966.21.1.1.1.2.3.1.4 | YesNoValue | read-write | current |
| alertSyslogGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.3.2 | |||
| syslogStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.2.1 | ContainerStatus | read-write | current |
| syslogEnabled OBJECT-TYPE Determines whether syslog is enabled. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.2.2 | YesNoValue | read-write | current |
| syslogSeverityLevel OBJECT-TYPE Choose the severity level that will trigger a syslog message: Emergency, Alert, Critical, Error, Warning, Notice, Info, Debug When you select a severity level, all the levels that appear above it in the list will also trigger a syslog message. For example, if you select Error, all Error, Critical, Alert, and Emergency events will generate a syslog message. NOTE: In addition to alert events, syslog message will also be generated for several non-alert system events | 1.3.6.1.4.1.1966.21.1.1.1.2.3.2.3 | INTEGER {emergency(0), alert(1), critical(2), error(3), warning(4), notice(5), informational(6), debug(7)} | read-write | current |
| syslogPrimaryHost OBJECT-TYPE The first preconfigured host that the management module will attempt to send system log messages to; messages will be displayed on the host's monitor. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.2.4 | DisplayString (SIZE(0..14)) | read-write | current |
| syslogSecondaryHost OBJECT-TYPE If the management module cannot communicate with the primary host, then the management module will attempt to send system log messages to this preconfigured host; messages will be displayed on the host's monitor. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.2.5 | DisplayString (SIZE(0..14)) | read-write | current |
| alertSnmpTrapGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3 | |||
| snmpTrapStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.1 | ContainerStatus | read-write | current |
| snmpTrapEnabled OBJECT-TYPE Determines whether SNMP Traps are enabled. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.2 | YesNoValue | read-write | current |
| snmpTrapAlertLevel OBJECT-TYPE Choose the alert level that will trigger a SNMP trap message to be sent if SNMP traps is enabled. When you select an alert level, all alerts that appear above it in the list will also trigger a local event log message. For example, if you select oneTimeError, all oneTimeError, persistantError, moduleLevelFault, and systemLevelFault alert events will be generate a SNMP trap message. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.3 | AlertSeverityLevel | read-write | current |
| snmpTrapHostTable OBJECT-TYPE Table of SNMP Trap Hosts information. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4 | not-accessible | current | |
| snmpTrapHostEntry OBJECT-TYPE Entries of the table, each relating to a separate SNMP trap host. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1 | not-accessible | current | |
| snmpTrapHostIndex OBJECT-TYPE This object identifies the SNMP trap host index. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.1 | GenericTableIndex | accessible-for-notify | current |
| snmpTrapHostStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.2 | ContainerStatus | read-write | current |
| snmpTrapHostIpAddress OBJECT-TYPE Defines the hosts (by IP address) that will receive trap messages generated by the management module. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.3 | Ipv4v6Address | read-write | current |
| snmpTrapHostUdpPort OBJECT-TYPE Defines the UDP port number the SNMP trap host will listen on to receive trap messages generated by the management module. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.4 | Integer32 (1..65535) | read-write | current |
| snmpTrapHostVersion OBJECT-TYPE Defines the SNMP version of the traps sent to this host. If snmpTrapV3 is selected then the SNMP trap v3 user | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.5 | INTEGER {snmpTrapV1(0), snmpTrapV2c(1), snmpTrapV3(2)} | read-write | current |
| snmpTrapHostType OBJECT-TYPE If set to snmpInform(1) the management module will send traps via an INFORM-PDU, expecting a response from the trap host, retransmitting if required. Otherwise it will send them via a TRAP-PDU or TRAP2-PDU. This object is ignored for for SNMP v1 | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.6 | INTEGER {snmpTrap(0), snmpInform(1)} | read-write | current |
| snmpTrapHostCommunity OBJECT-TYPE An arbitrary trap community name. This object is ignored for SNMP v3 | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.7 | DisplayString (SIZE(0..14)) | read-write | current |
| snmpTrapHostEnable OBJECT-TYPE If set to No, the management module will not use this table entry to send traps. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.4.1.8 | YesNoValue | read-write | current |
| snmpV3TrapUser OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5 | |||
| snmpV3TrapUserStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.1 | ContainerStatus | read-write | current |
| snmpV3TrapUserUserName OBJECT-TYPE SNMP trap v3 user name. This user will be used for every SNMP trap host that is using snmpTrapHostVersion of snmpTrapV3(2) | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.2 | DisplayString (SIZE(0..16)) | read-write | current |
| snmpV3TrapUserSecurityLevel OBJECT-TYPE SNMP trap v3 user security level. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.3 | INTEGER {none(0), authNoPriv(1), authPriv(2)} | read-write | current |
| snmpV3TrapUserAuthAlgorithm OBJECT-TYPE SNMP trap v3 user authentication method. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.4 | INTEGER {md5(0), sha(1)} | read-write | current |
| snmpV3TrapUserAuthPasswd OBJECT-TYPE SNMP trap v3 user authentication password. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.5 | DisplayString (SIZE(0..128)) | read-write | current |
| snmpV3TrapUserPrivacyAlgorithm OBJECT-TYPE SNMP trap v3 user privacy algorithm. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.6 | INTEGER {des(0), aes(1)} | read-write | current |
| snmpV3TrapUserPrivacyPasswd OBJECT-TYPE SNMP trap v3 user privacy password. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.5.7 | DisplayString (SIZE(0..128)) | read-write | current |
| snmpTrapGlbHostTimeout OBJECT-TYPE Defines the timeout in miliseconds between retries of sending the SNMP INFORM-PDU if no response is received for the trap host. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.6 | Integer32 (0..65535) | read-write | current |
| snmpTapGlobHostRetries OBJECT-TYPE Defines the number of retries to send the SNMP INFORM-PDU trap if no response is received from the trap host. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.7 | Integer32 (0..65535) | read-write | current |
| snmpV3LocalEngineID OBJECT-TYPE An SNMPv3 engine ID used by the MCR-MGT for identification when sending SNMP v3 traps. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.8 | SnmpEngineID | read-only | current |
| snmpV3LocalEngineIDTextSuffix OBJECT-TYPE This configured text is used to build the suffix of the SNMPv3 engine ID | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.9 | DisplayString (SIZE(0..27)) | read-write | current |
| snmpTrapVarsGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10 | |||
| mgtAccessMethod OBJECT-TYPE Defines the management protocol used to access the management module | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.1 | INTEGER {mgtConsole(1), mgtSnmp(2), mgtTelnet(3), mgtSSH(4), mgtHTTP(5), mgtHTTPS(6)} | accessible-for-notify | current |
| remoteMgtIpAddress OBJECT-TYPE Defines the remote IP address accessing the management module | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.2 | DisplayString | accessible-for-notify | current |
| remoteTftpHost OBJECT-TYPE Defines the remote TFTP server IP address or host name performing the TFP file transfer | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.3 | DisplayString (SIZE(0..64)) | accessible-for-notify | current |
| remoteTftpFileName OBJECT-TYPE Defines the remote TFTP file name | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.4 | DisplayString (SIZE(0..64)) | accessible-for-notify | current |
| networkIpAddress OBJECT-TYPE Defines the IP address assigned to the management module | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.5 | Ipv4v6Address | accessible-for-notify | current |
| mcrMediaPortNum OBJECT-TYPE This object identifies the media converter module port number. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.6 | Unsigned32 (1..2) | accessible-for-notify | current |
| mcrMediaPortDescr OBJECT-TYPE A description of the media port that consists of the user defined media port name, followed by the system name for the port. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.7 | DisplayString | accessible-for-notify | current |
| eventSeverityLevel OBJECT-TYPE The severity level of the event that generated this trap. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.8 | AlertSeverityLevel | accessible-for-notify | current |
| xfpDmiRealTimeAux OBJECT-TYPE This object identifies the XFP DMI real time values for one of the auxillary register sets. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.9 | DisplayString (SIZE(0..32)) | read-only | current |
| xfpDmiHighAuxWarn OBJECT-TYPE This object identifies the XFP DMI high warning threshold for one of the auxillary register sets. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.10 | DisplayString (SIZE(0..32)) | read-only | current |
| xfpDmiHighAuxAlarm OBJECT-TYPE This object identifies the XFP DMI alarm alarm threshold for one of the auxillary register sets. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.11 | DisplayString (SIZE(0..32)) | read-only | current |
| xfpDmiLowAuxWarn OBJECT-TYPE This object identifies the XFP DMI low warning threshold for one of the auxillary register sets. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.12 | DisplayString (SIZE(0..32)) | read-only | current |
| xfpDmiLowAuxAlarm OBJECT-TYPE This object identifies the XFP DMI low alarm threshold for one of the auxillary register sets. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.13 | DisplayString (SIZE(0..32)) | read-only | current |
| mcrModuleSubTypeInserted OBJECT-TYPE This object identifies the module sub-type inserted in the slot. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.14 | INTEGER {blank(-1), sts(0), xts(1), xtsh(2), xtx(3), xtxh(4)} | read-only | current |
| mcrMediaBackedupModuleSubType OBJECT-TYPE This object identifies the module sub-type of the backup configuration. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.15 | INTEGER {blank(-1), sts(0), xts(1), xtsh(2), xtx(3), xtxh(4)} | read-only | current |
| mcrMediaPortBandwidth OBJECT-TYPE This object identifies the media converter module port's current bandwith in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.16 | Unsigned32 | accessible-for-notify | current |
| mcrMediaPortBandwidthThreshold OBJECT-TYPE This object identifies the media converter module port's bandwith threshold in kbps. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.3.10.17 | Unsigned32 | accessible-for-notify | current |
| alertEmailGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4 | |||
| emailStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.1 | ContainerStatus | read-write | current |
| emailEnabled OBJECT-TYPE Determines whether or not email notification is turned on. Default is Off. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.2 | YesNoValue | read-write | current |
| emailAlertLevel OBJECT-TYPE Choose the alert level that will trigger a email message to be sent if alert email is enabled. When you select an alert level, all alerts that appear above it in the list will also trigger a local event log message. For example, if you select oneTimeError, all oneTimeError, persistantError, moduleLevelFault, and systemLevelFault alert events will be generate a email message. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.3 | AlertSeverityLevel | read-write | current |
| emailTo OBJECT-TYPE An email address or list of email addresses that will receive the email notification. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.4 | DisplayString (SIZE(0..64)) | read-write | current |
| emailFrom OBJECT-TYPE This field can contain an email address that might identify the management module name or some other value. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.5 | DisplayString (SIZE(0..32)) | read-write | current |
| emailSMTPHost OBJECT-TYPE The SMTP host (email server) that will process the email notification request. This can be either a host name defined in the management module host table or the SMTP host IP address. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.6 | DisplayString (SIZE(0..64)) | read-write | current |
| emailReply OBJECT-TYPE The email address to whom all replies to the email notification should go. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.7 | DisplayString (SIZE(0..32)) | read-write | current |
| emailSubject OBJECT-TYPE A text string, which can contain spaces, that will display in the Subject field of the email notification. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.8 | DisplayString (SIZE(0..48)) | read-write | current |
| emailSMTPUsername OBJECT-TYPE The user name for the SMTP server, if the server requires authentication. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.9 | DisplayString (SIZE(0..64)) | read-write | current |
| emailSMTPPassword OBJECT-TYPE The password for the SMTP server, if the server requires authentication. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.10 | DisplayString (SIZE(0..64)) | read-write | current |
| emailSMTPEncryption OBJECT-TYPE The encryption method for the SMTP server. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.11 | INTEGER {none(1), tls(2), ssl(3)} | read-write | current |
| emailSMTPValidatePeerCertificate OBJECT-TYPE Validate peer SSL/TLS certificate, when SSL or TLS encryption is used. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.12 | OnOffValue | read-write | current |
| emailSMTPTcpPort OBJECT-TYPE The TCP port used for communicating with the SMTP server. For no encryption or TLS encryption, use port 25. For SSL encryption, use port 465. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.13 | Integer32 (1..65535) | read-write | current |
| emailSMTPDomain OBJECT-TYPE The domain for NTLM authentication with the SMTP server, if applicable. | 1.3.6.1.4.1.1966.21.1.1.1.2.3.4.14 | DisplayString (SIZE(0..32)) | read-write | current |
| mgtUsersGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.4 | |||
| mgtUsersStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.1 | ContainerStatus | read-write | current |
| mgtUsersByPassLoginEnabled OBJECT-TYPE Indicates whether by pass login is enabled. When enable users will be automatically login as admin user. The will not be prompted for a user ID or password when accessing the management module. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.2 | OnOffValue | read-write | current |
| mgtUsersPrimaryAuthMethod OBJECT-TYPE The first authentication method that the management module attempts. Some type of authentication must be done by the management module. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.3 | INTEGER {local(1), radius(2), kerberos(3), ldap(4), tacacs(5), securid(6), nis(7)} | read-write | current |
| mgtUsersSecondaryAuthMethod OBJECT-TYPE If the Primary Authentication Method fails, the next authentication method that the management module attempts. You can choose to use authentication methods in combination. For example, you can specify the Primary Authentication Method as Local and the Secondary Authentication Method as RADIUS. Therefore, some users can be defined in the Device Server (Local) others in RADIUS. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.4 | INTEGER {none(1), local(2), radius(3), kerberos(4), ldap(5), tacacs(6), securid(7), nis(8)} | read-write | current |
| mgtUsersAlwaysAttemptSecond OBJECT-TYPE If enabled, the secondary authentication method will always be used. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.5 | OnOffValue | read-write | current |
| localUserAccountsTable OBJECT-TYPE Table of locally defined user information | 1.3.6.1.4.1.1966.21.1.1.1.2.4.6 | not-accessible | current | |
| localUserAccountsEntry OBJECT-TYPE Entries of the table, each relating to separate user defined locally. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1 | not-accessible | current | |
| userIndex OBJECT-TYPE The table entry number for this user. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1.1 | GenericTableIndex | not-accessible | current |
| userStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1.2 | ContainerStatus | read-write | current |
| userName OBJECT-TYPE The user name. To delete a user, set this field to blank. If blank, this entry is currently unused. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1.3 | DisplayString (SIZE(0..16)) | read-write | current |
| userPassword OBJECT-TYPE The password for the local user. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1.4 | DisplayString (SIZE(0..64)) | read-write | current |
| userLevel OBJECT-TYPE Admin: Total access to the management module. More than one admin user account can exist, but we recommend that you only have one. operator: Full read only access to configuration and limited control commands | 1.3.6.1.4.1.1966.21.1.1.1.2.4.6.1.5 | INTEGER {admin(0), operator(1)} | read-write | current |
| localUsersStatusTable OBJECT-TYPE Table of locally defined user information | 1.3.6.1.4.1.1966.21.1.1.1.2.4.7 | not-accessible | current | |
| localUsersStatusEntry OBJECT-TYPE Entries of the table, each relating to separate user defined locally. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1 | not-accessible | current | |
| userStatusIndex OBJECT-TYPE The table entry number for this user status. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.1 | GenericTableIndex | not-accessible | current |
| userStatusName OBJECT-TYPE The user name. To delete a user, set this field to blank. If blank, this entry is currently unused. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.2 | DisplayString (SIZE(0..16)) | read-only | current |
| userStatusMgtAccessType OBJECT-TYPE Defines the management protocol used to access the management module | 1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.3 | INTEGER {mgtAccessHTTP(1), mgtAccessHTTPS(2), mgtAccessTelnet(3), mgtAccessSSH(4), mgtAccessConsole(5)} | not-accessible | current |
| userStatusRemoteIPAddress OBJECT-TYPE This object specifies the remote IP address user management session. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.4 | Ipv4v6Address | read-only | current |
| userStatusStartTime OBJECT-TYPE This object identifies the date and time that the current user's management session started. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.5 | DisplayString | read-only | current |
| userStatusLevel OBJECT-TYPE Admin: Total access to the management module. More than one admin user account can exist, but we recommend that you only have one. operator: Full read only access to configuration and limited control commands | 1.3.6.1.4.1.1966.21.1.1.1.2.4.7.1.6 | INTEGER {admin(0), operator(1)} | read-only | current |
| radiusGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8 | |||
| radiusStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.1 | ContainerStatus | read-write | current |
| radiusPrimaryAuthHost OBJECT-TYPE Primary Radius Authentication Host | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.2 | DisplayString (SIZE(0..14)) | read-write | current |
| radiusSecondaryAuthHost OBJECT-TYPE Secondary Radius Authentication Host | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.3 | DisplayString (SIZE(0..14)) | read-write | current |
| radiusAuthenticationPort OBJECT-TYPE The port that the RADIUS host listens to for authentication requests. The default port is 1812. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.4 | Integer32 (0..65535) | read-write | current |
| radiusAccounting OBJECT-TYPE Radius Accounting | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.5 | OnOffValue | read-write | current |
| radiusPrimaryAcctHost OBJECT-TYPE Name of the primary RADIUS authentication host. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.6 | DisplayString (SIZE(0..14)) | read-write | current |
| radiusSecondaryAcctHost OBJECT-TYPE Name of the secondary RADIUS authentication host. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.7 | DisplayString (SIZE(0..14)) | read-write | current |
| radiusAccountingPort OBJECT-TYPE The port that the RADIUS host listens to for accounting requests. The default port is 1813. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.8 | Integer32 (0..65535) | read-write | current |
| radiusAcctAuth OBJECT-TYPE Radius Accounting Authenticator | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.9 | OnOffValue | read-write | current |
| radiusRetryLimit OBJECT-TYPE The number of times the management module tries to connect to the RADIUS server before erroring out. Valid values are 0-255. The default is 5. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.10 | Integer32 (0..255) | read-write | current |
| radiusTimeout OBJECT-TYPE The time, in seconds, that the management module waits to receive a reply after sending out a request to a RADIUS accounting or authentication host. If no reply is received before the timeout period expires, the management module will retry the same host up to and including the number of retry attempts. Valid values are 1-255. The default is 3 seconds. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.11 | Integer32 (1..255) | read-write | current |
| radiusNasIdentifier OBJECT-TYPE The NAS identifier name. To delete this , set this field to blank. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.12 | DisplayString (SIZE(0..32)) | read-write | current |
| radiusNasIpAddress OBJECT-TYPE When on, the NAS Identifier obtains ipv4 address automatically. Default is on. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.13 | OnOffValue | read-write | current |
| radiusNasSpecifyIpAddress OBJECT-TYPE Specify the unique IPv4 address that NAS Identifier will use | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.14 | IpAddress | read-write | current |
| radiusNasIpv6Address OBJECT-TYPE When on, the NAS Identifier obtains ipv6 address automatically. Default is on. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.15 | OnOffValue | read-write | current |
| radiusNasSpecifyIpv6Address OBJECT-TYPE Specify the unique IPv6 address that NAS Identifier will use | 1.3.6.1.4.1.1966.21.1.1.1.2.4.8.16 | DisplayString | read-write | current |
| kerberosGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.4.9 | |||
| kerberosStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.9.1 | ContainerStatus | read-write | current |
| kerberosRealm OBJECT-TYPE The Kerberos realm is the Kerberos host domain name, in upper-case letters. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.9.2 | DisplayString (SIZE(0..32)) | read-write | current |
| kerberosDomain OBJECT-TYPE The name of a host running the KDC (Key Distribution Center) for the specified realm. The host name that you specify must either be defined in the management module's host Table before the last reboot or be resolved by DNS. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.9.3 | DisplayString (SIZE(0..32)) | read-write | current |
| kerberosPort OBJECT-TYPE The port that the Kerberos server listens to for authentication requests. If no port is specified, the default port 88 is used. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.9.4 | Integer32 (0..65535) | read-write | current |
| ldapGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10 | |||
| ldapStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.1 | ContainerStatus | read-write | current |
| ldapHost OBJECT-TYPE The name or IP address of the LDAP host. If you use a host name, that host must either have been defined in the management module's Host Table before the last reboot or be resolved by DNS. If you are using TLS, you must enter the same string you used to create the LDAP certificate. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.2 | DisplayString (SIZE(0..64)) | read-write | current |
| ldapPort OBJECT-TYPE The port that the LDAP host listens to for authentication requests. The default port is 389. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.3 | Integer32 (0..65535) | read-write | current |
| ldapBase OBJECT-TYPE The domain component (dc) that is the starting point for the search for user authentication. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.4 | DisplayString (SIZE(0..64)) | read-write | current |
| ldapEnableTLS OBJECT-TYPE Enables/disables the Transport Layer Security (TLS) with the LDAP host. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.5 | OnOffValue | read-write | current |
| ldapTLSPort OBJECT-TYPE Specify the port number that LDAP will use for TLS. The default is port 636. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.6 | Integer32 (0..65535) | read-write | current |
| ldapUID OBJECT-TYPE LDAP user attribute. e.g. uid (OpenLDAP) sAMAccountName (Active Directory) The default is 'uid'. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.7 | DisplayString (SIZE(0..32)) | read-write | current |
| ldapPasswordEncryption OBJECT-TYPE LDAP password encryption method. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.8 | INTEGER {none(1), md5(2)} | read-write | current |
| ldapClientAuth OBJECT-TYPE LDAP client authentication. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.9 | OnOffValue | read-write | current |
| ldapClientName OBJECT-TYPE LDAP client name. Identifies the unit to the LDAP server, when client authentication is . | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.10 | DisplayString (SIZE(0..64)) | read-write | current |
| ldapClientAppendBase OBJECT-TYPE Append base to LDAP client name. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.11 | OnOffValue | read-write | current |
| ldapClientPassword OBJECT-TYPE LDAP client password. Identifies the unit to the LDAP server, when client authentication is . | 1.3.6.1.4.1.1966.21.1.1.1.2.4.10.12 | DisplayString (SIZE(0..64)) | read-write | current |
| tacacsGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11 | |||
| tacacsStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.1 | ContainerStatus | read-write | current |
| tacacsPrimaryHost OBJECT-TYPE The primary TACACS+ host that is used for authentication. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.2 | DisplayString (SIZE(0..14)) | read-write | current |
| tacacsSecondaryHost OBJECT-TYPE The secondary TACACS+ host that is used for authentication, should the primary TACACS+ host fail to respond. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.3 | DisplayString (SIZE(0..14)) | read-write | current |
| tacacsPort OBJECT-TYPE The port number that TACACS+ listens to for authentication requests. The default port number is 49. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.4 | Integer32 (0..65535) | read-write | current |
| tacacsAccounting OBJECT-TYPE Enable/Disable TACACS+ accounting | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.5 | OnOffValue | read-write | current |
| tacacsAccountingPrimaryHost OBJECT-TYPE The primary TACACS+ accounting host that is used for. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.6 | DisplayString (SIZE(0..14)) | read-write | current |
| tacacsAccountingSecondaryHost OBJECT-TYPE The secondary TACACS+ accounting host that is used for , should the primary TACACS+ host fail to respond. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.7 | DisplayString (SIZE(0..14)) | read-write | current |
| tacacsAccountingPort OBJECT-TYPE The port number that TACACS+ listens to for accounting requests. The default port number is 49. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.8 | Integer32 (0..65535) | read-write | current |
| tacacsAuthorization OBJECT-TYPE Enable/Disable TACACS+ authorization | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.9 | OnOffValue | read-write | current |
| tacacsAlternateServiceNames OBJECT-TYPE Enable alternate service names for TACACS+. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.11.10 | OnOffValue | read-write | current |
| securidGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.4.12 | |||
| securidStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.12.1 | ContainerStatus | read-write | current |
| securidMasterHost OBJECT-TYPE The first SecurID server that is tried for user authentication. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.12.2 | DisplayString (SIZE(0..14)) | read-write | current |
| securidSlaveHost OBJECT-TYPE If the first SecurID server does not respond to an authentication request, this is the next SecurID server that is tried for user authentication. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.12.3 | DisplayString (SIZE(0..14)) | read-write | current |
| securidPort OBJECT-TYPE The port number that SecurID listens to for authentication requests. The default port number is 5500. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.12.4 | Integer32 (0..65535) | read-write | current |
| securidType OBJECT-TYPE You can specify either SDI or DES encryption for SecurID server communication. The default is SDI encryption. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.12.5 | INTEGER {des(1), sdi(2)} | read-write | current |
| securidLegacy OBJECT-TYPE If you are running SecurID 3.x or 4.x, you need to run in Legacy Mode. If you are running SecurID 5.x or above, do not select Legacy Mode. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.12.6 | YesNoValue | read-write | current |
| nisGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.4.13 | |||
| nisStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.13.1 | ContainerStatus | read-write | current |
| nisDomain OBJECT-TYPE The NIS domain name. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.13.2 | DisplayString (SIZE(0..32)) | read-write | current |
| nisPrimaryHost OBJECT-TYPE The primary NIS host that is used for authentication. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.13.3 | DisplayString (SIZE(0..14)) | read-write | current |
| nisSecondaryHost OBJECT-TYPE The secondary NIS host that is used for authentication, should the primary NIS host fail to respond. | 1.3.6.1.4.1.1966.21.1.1.1.2.4.13.4 | DisplayString (SIZE(0..14)) | read-write | current |
| mgtDateTimeGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.5 | |||
| mgtDateTimeStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.1 | ContainerStatus | read-write | current |
| systemDate OBJECT-TYPE The system date. Format dd/mm/yyyy. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.2 | DisplayString | read-write | current |
| systemTime OBJECT-TYPE The system time (local time). Format hh:mm:ss. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.3 | DisplayString | read-write | current |
| systemDateTimeAndOffset OBJECT-TYPE This read only object identifies the current system date, time and GMT offset. The date and time will be displayed in the regional time format configured. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.4 | DisplayString | read-only | current |
| timeZoneListEnable OBJECT-TYPE When the time zone list is enabled then the time zone being use is the one selected form the predefined list of time zones. If not enabled then the customTimeZoneGroup will define the time zone being used | 1.3.6.1.4.1.1966.21.1.1.1.2.5.5 | OnOffValue | read-write | current |
| selectionFromTimeZoneList OBJECT-TYPE This object identifies the predefined time zone selected. This time zone will be used if timeZoneListEnable object is set to yes. configured. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.6 | INTEGER {tzAfricaAbidjan(0), tzAfricaAccra(1), tzAfricaAddisAbaba(2), tzAfricaAlgiers(3), tzAfricaAsmera(4), tzAfricaBamako(5), tzAfricaBangui(6), tzAfricaBanjul(7), tzAfricaBissau(8), tzAfricaBlantyre(9), tzAfricaBrazzaville(10), tzAfricaBujumbura(11), tzAfricaCairo(12), tzAfricaCasablanca(13), tzAfricaCeuta(14), tzAfricaConakry(15), tzAfricaDakar(16), tzAfricaDaresSalaam(17), tzAfricaDjibouti(18), tzAfricaDouala(19), tzAfricaElAaiun(20), tzAfricaFreetown(21), tzAfricaGaborone(22), tzAfricaHarare(23), tzAfricaJohannesburg(24), tzAfricaKampala(25), tzAfricaKhartoum(26), tzAfricaKigali(27), tzAfricaKinshasa(28), tzAfricaLagos(29), tzAfricaLibreville(30), tzAfricaLome(31), tzAfricaLuanda(32), tzAfricaLubumbashi(33), tzAfricaLusaka(34), tzAfricaMalabo(35), tzAfricaMaputo(36), tzAfricaMaseru(37), tzAfricaMbabane(38), tzAfricaMogadishu(39), tzAfricaMonrovia(40), tzAfricaNairobi(41), tzAfricaNdjamena(42), tzAfricaNiamey(43), tzAfricaNouakchott(44), tzAfricaOuagadougou(45), tzAfricaPortoNovo(46), tzAfricaSaoTome(47), tzAfricaTimbuktu(48), tzAfricaTripoli(49), tzAfricaTunis(50), tzAfricaWindhoek(51), tzAmericaAdak(52), tzAmericaAnchorage(53), tzAmericaAnguilla(54), tzAmericaAntigua(55), tzAmericaAraguaina(56), tzAmericaAruba(57), tzAmericaAsuncion(58), tzAmericaAtka(59), tzAmericaBarbados(60), tzAmericaBelem(61), tzAmericaBelize(62), tzAmericaBoaVista(63), tzAmericaBogota(64), tzAmericaBoise(65), tzAmericaBuenosAires(66), tzAmericaCambridgeBay(67), tzAmericaCancun(68), tzAmericaCaracas(69), tzAmericaCatamarca(70), tzAmericaCayenne(71), tzAmericaCayman(72), tzAmericaChicago(73), tzAmericaChihuahua(74), tzAmericaCordoba(75), tzAmericaCostaRica(76), tzAmericaCuiaba(77), tzAmericaCuracao(78), tzAmericaDanmarkshavn(79), tzAmericaDawson(80), tzAmericaDawsonCreek(81), tzAmericaDenver(82), tzAmericaDetroit(83), tzAmericaDominica(84), tzAmericaEdmonton(85), tzAmericaEirunepe(86), tzAmericaElSalvador(87), tzAmericaEnsenada(88), tzAmericaFortWayne(89), tzAmericaFortaleza(90), tzAmericaGlaceBay(91), tzAmericaGodthab(92), tzAmericaGooseBay(93), tzAmericaGrandTurk(94), tzAmericaGrenada(95), tzAmericaGuadeloupe(96), tzAmericaGuatemala(97), tzAmericaGuayaquil(98), tzAmericaGuyana(99), tzAmericaHalifax(100), tzAmericaHavana(101), tzAmericaHermosillo(102), tzAmericaIndianaIndianapolis(103), tzAmericaIndianaKnox(104), tzAmericaIndianaMarengo(105), tzAmericaIndianaVevay(106), tzAmericaIndianapolis(107), tzAmericaInuvik(108), tzAmericaIqaluit(109), tzAmericaJamaica(110), tzAmericaJujuy(111), tzAmericaJuneau(112), tzAmericaKentuckyLouisville(113), tzAmericaKentuckyMonticello(114), tzAmericaKnoxIN(115), tzAmericaLaPaz(116), tzAmericaLima(117), tzAmericaLosAngeles(118), tzAmericaLouisville(119), tzAmericaMaceio(120), tzAmericaManagua(121), tzAmericaManaus(122), tzAmericaMartinique(123), tzAmericaMazatlan(124), tzAmericaMendoza(125), tzAmericaMenominee(126), tzAmericaMerida(127), tzAmericaMexicoCity(128), tzAmericaMiquelon(129), tzAmericaMonterrey(130), tzAmericaMontevideo(131), tzAmericaMontreal(132), tzAmericaMontserrat(133), tzAmericaNassau(134), tzAmericaNewYork(135), tzAmericaNipigon(136), tzAmericaNome(137), tzAmericaNoronha(138), tzAmericaNorthDakotaCenter(139), tzAmericaPanama(140), tzAmericaPangnirtung(141), tzAmericaParamaribo(142), tzAmericaPhoenix(143), tzAmericaPortofSpain(144), tzAmericaPortauPrince(145), tzAmericaPortoAcre(146), tzAmericaPortoVelho(147), tzAmericaPuertoRico(148), tzAmericaRainyRiver(149), tzAmericaRankinInlet(150), tzAmericaRecife(151), tzAmericaRegina(152), tzAmericaRioBranco(153), tzAmericaRosario(154), tzAmericaSantiago(155), tzAmericaSantoDomingo(156), tzAmericaSaoPaulo(157), tzAmericaScoresbysund(158), tzAmericaShiprock(159), tzAmericaStJohns(160), tzAmericaStKitts(161), tzAmericaStLucia(162), tzAmericaStThomas(163), tzAmericaStVincent(164), tzAmericaSwiftCurrent(165), tzAmericaTegucigalpa(166), tzAmericaThule(167), tzAmericaThunderBay(168), tzAmericaTijuana(169), tzAmericaTortola(170), tzAmericaVancouver(171), tzAmericaVirgin(172), tzAmericaWhitehorse(173), tzAmericaWinnipeg(174), tzAmericaYakutat(175), tzAmericaYellowknife(176), tzAntarcticaCasey(177), tzAntarcticaDavis(178), tzAntarcticaDumontDUrville(179), tzAntarcticaMawson(180), tzAntarcticaMcMurdo(181), tzAntarcticaPalmer(182), tzAntarcticaSouthPole(183), tzAntarcticaSyowa(184), tzAntarcticaVostok(185), tzArcticLongyearbyen(186), tzAsiaAden(187), tzAsiaAlmaty(188), tzAsiaAmman(189), tzAsiaAnadyr(190), tzAsiaAqtau(191), tzAsiaAqtobe(192), tzAsiaAshgabat(193), tzAsiaAshkhabad(194), tzAsiaBaghdad(195), tzAsiaBahrain(196), tzAsiaBaku(197), tzAsiaBangkok(198), tzAsiaBeirut(199), tzAsiaBishkek(200), tzAsiaBrunei(201), tzAsiaCalcutta(202), tzAsiaChoibalsan(203), tzAsiaChongqing(204), tzAsiaChungking(205), tzAsiaColombo(206), tzAsiaDacca(207), tzAsiaDamascus(208), tzAsiaDhaka(209), tzAsiaDili(210), tzAsiaDubai(211), tzAsiaDushanbe(212), tzAsiaGaza(213), tzAsiaHarbin(214), tzAsiaHongKong(215), tzAsiaHovd(216), tzAsiaIrkutsk(217), tzAsiaIstanbul(218), tzAsiaJakarta(219), tzAsiaJayapura(220), tzAsiaJerusalem(221), tzAsiaKabul(222), tzAsiaKamchatka(223), tzAsiaKarachi(224), tzAsiaKashgar(225), tzAsiaKatmandu(226), tzAsiaKrasnoyarsk(227), tzAsiaKualaLumpur(228), tzAsiaKuching(229), tzAsiaKuwait(230), tzAsiaMacao(231), tzAsiaMagadan(232), tzAsiaManila(233), tzAsiaMuscat(234), tzAsiaNicosia(235), tzAsiaNovosibirsk(236), tzAsiaOmsk(237), tzAsiaPhnomPenh(238), tzAsiaPontianak(239), tzAsiaPyongyang(240), tzAsiaQatar(241), tzAsiaRangoon(242), tzAsiaRiyadh(243), tzAsiaSaigon(244), tzAsiaSakhalin(245), tzAsiaSamarkand(246), tzAsiaSeoul(247), tzAsiaShanghai(248), tzAsiaSingapore(249), tzAsiaTaipei(250), tzAsiaTashkent(251), tzAsiaTbilisi(252), tzAsiaTehran(253), tzAsiaTelAviv(254), tzAsiaThimbu(255), tzAsiaThimphu(256), tzAsiaTokyo(257), tzAsiaUjungPandang(258), tzAsiaUlaanbaatar(259), tzAsiaUlanBator(260), tzAsiaUrumqi(261), tzAsiaVientiane(262), tzAsiaVladivostok(263), tzAsiaYakutsk(264), tzAsiaYekaterinburg(265), tzAsiaYerevan(266), tzAtlanticAzores(267), tzAtlanticBermuda(268), tzAtlanticCanary(269), tzAtlanticCapeVerde(270), tzAtlanticFaeroe(271), tzAtlanticJanMayen(272), tzAtlanticMadeira(273), tzAtlanticReykjavik(274), tzAtlanticSouthGeorgia(275), tzAtlanticStHelena(276), tzAtlanticStanley(277), tzAustraliaACT(278), tzAustraliaAdelaide(279), tzAustraliaBrisbane(280), tzAustraliaBrokenHill(281), tzAustraliaCanberra(282), tzAustraliaDarwin(283), tzAustraliaHobart(284), tzAustraliaLHI(285), tzAustraliaLindeman(286), tzAustraliaLordHowe(287), tzAustraliaMelbourne(288), tzAustraliaNSW(289), tzAustraliaNorth(290), tzAustraliaPerth(291), tzAustraliaQueensland(292), tzAustraliaSouth(293), tzAustraliaSydney(294), tzAustraliaTasmania(295), tzAustraliaVictoria(296), tzAustraliaWest(297), tzAustraliaYancowinna(298), tzBrazilDeNoronha(299), tzBrazilEast(300), tzBrazilWest(301), tzCanadaAtlantic(302), tzCanadaCentral(303), tzCanadaEastSaskatchewan(304), tzCanadaEastern(305), tzCanadaMountain(306), tzCanadaNewfoundland(307), tzCanadaPacific(308), tzCanadaSaskatchewan(309), tzCanadaYukon(310), tzChileContinental(311), tzChileEasterIsland(312), tzCuba(313), tzEgypt(314), tzEire(315), tzEuropeAmsterdam(316), tzEuropeAndorra(317), tzEuropeAthens(318), tzEuropeBelfast(319), tzEuropeBelgrade(320), tzEuropeBerlin(321), tzEuropeBratislava(322), tzEuropeBrussels(323), tzEuropeBucharest(324), tzEuropeBudapest(325), tzEuropeChisinau(326), tzEuropeCopenhagen(327), tzEuropeDublin(328), tzEuropeGibraltar(329), tzEuropeHelsinki(330), tzEuropeIstanbul(331), tzEuropeKaliningrad(332), tzEuropeKiev(333), tzEuropeLisbon(334), tzEuropeLjubljana(335), tzEuropeLondon(336), tzEuropeLuxembourg(337), tzEuropeMadrid(338), tzEuropeMalta(339), tzEuropeMinsk(340), tzEuropeMonaco(341), tzEuropeMoscow(342), tzEuropeNicosia(343), tzEuropeOslo(344), tzEuropeParis(345), tzEuropePrague(346), tzEuropeRiga(347), tzEuropeRome(348), tzEuropeSamara(349), tzEuropeSanMarino(350), tzEuropeSarajevo(351), tzEuropeSimferopol(352), tzEuropeSkopje(353), tzEuropeSofia(354), tzEuropeStockholm(355), tzEuropeTallinn(356), tzEuropeTirane(357), tzEuropeTiraspol(358), tzEuropeUzhgorod(359), tzEuropeVaduz(360), tzEuropeVatican(361), tzEuropeVienna(362), tzEuropeVilnius(363), tzEuropeWarsaw(364), tzEuropeZagreb(365), tzEuropeZaporozhye(366), tzEuropeZurich(367), tzGreatBritainEire(368), tzGreatBritainGreatBritain(369), tzHongKong(370), tzIceland(371), tzIndianAntananarivo(372), tzIndianChagos(373), tzIndianChristmas(374), tzIndianCocos(375), tzIndianComoro(376), tzIndianKerguelen(377), tzIndianMahe(378), tzIndianMaldives(379), tzIndianMauritius(380), tzIndianMayotte(381), tzIndianReunion(382), tzIran(383), tzIsrael(384), tzJamaica(385), tzJapan(386), tzKwajalein(387), tzLibya(388), tzMexicoBajaNorte(389), tzMexicoBajaSur(390), tzMexicoGeneral(391), tzNavajo(392), tzNewZealandChatham(393), tzNewZealandNewZealand(394), tzPacificApia(395), tzPacificAuckland(396), tzPacificChatham(397), tzPacificEaster(398), tzPacificEfate(399), tzPacificEnderbury(400), tzPacificFakaofo(401), tzPacificFiji(402), tzPacificFunafuti(403), tzPacificGalapagos(404), tzPacificGambier(405), tzPacificGuadalcanal(406), tzPacificGuam(407), tzPacificHonolulu(408), tzPacificJohnston(409), tzPacificKiritimati(410), tzPacificKosrae(411), tzPacificKwajalein(412), tzPacificMajuro(413), tzPacificMarquesas(414), tzPacificMidway(415), tzPacificNauru(416), tzPacificNiue(417), tzPacificNorfolk(418), tzPacificNoumea(419), tzPacificPagoPago(420), tzPacificPalau(421), tzPacificPitcairn(422), tzPacificPonape(423), tzPacificPortMoresby(424), tzPacificRarotonga(425), tzPacificSaipan(426), tzPacificSamoa(427), tzPacificTahiti(428), tzPacificTarawa(429), tzPacificTongatapu(430), tzPacificTruk(431), tzPacificWake(432), tzPacificWallis(433), tzPacificYap(434), tzPoland(435), tzPortugal(436), tzSingapore(437), tzTurkey(438), tzUSAlaska(439), tzUSAleutian(440), tzUSArizona(441), tzUSCentral(442), tzUSEastIndiana(443), tzUSEastern(444), tzUSHawaii(445), tzUSIndianaStarke(446), tzUSMichigan(447), tzUSMountain(448), tzUSPacific(449), tzUSSamoa(450)} | read-write | current |
| timeZoneAdjustForDST OBJECT-TYPE This object identifies if the time will be adjusted for DST (Daylight Savings Time) or not. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.7 | YesNoValue | read-write | current |
| customTimeZoneGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8 | |||
| customTimeZoneStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.1 | ContainerStatus | read-write | current |
| timeZoneName OBJECT-TYPE The name of the time zone when using standard time. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.2 | DisplayString (SIZE(0..4)) | read-write | current |
| timeOffset OBJECT-TYPE The offset of summer time from standard time in minutes. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.3 | Integer32 (-720..840) | read-write | current |
| timeSummerName OBJECT-TYPE The name of the time zone when using summer time. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.4 | DisplayString (SIZE(0..4)) | read-write | current |
| timeSummerOffset OBJECT-TYPE The offset of summer time from standard time in minutes. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.5 | Integer32 (0..180) | read-write | current |
| timeSummerMode OBJECT-TYPE You can configure the summer time to take effect: None-No summer time change. Fixed-The summer time change goes into effect at the specified time every year. For example, April 15 at 1:00 pm. Recurring-The summer time changes goes into effect every year at same relative time. For example, on the third week in April on a Tuesday at 1:00 pm. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.6 | INTEGER {disabled(0), fixed(1), recurring(2)} | read-write | current |
| timeSummerRecStartMonth OBJECT-TYPE The recurring summer time start month. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.7 | INTEGER {january(0), february(1), march(2), april(3), may(4), june(5), july(6), august(7), september(8), october(9), november(10), december(11)} | read-write | current |
| timeSummerRecStartWeek OBJECT-TYPE The recurring summer time start week. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.8 | INTEGER {first(0), second(1), third(2), fourth(3), last(4)} | read-write | current |
| timeSummerRecStartDay OBJECT-TYPE The recurring summer time start day. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.9 | INTEGER {sunday(0), monday(1), tuesday(2), wednesday(3), thursday(4), friday(5), saturday(6)} | read-write | current |
| timeSummerRecStartHour OBJECT-TYPE The recurring summer time start hour. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.10 | Integer32 (0..23) | read-write | current |
| timeSummerRecStartMin OBJECT-TYPE The recurring summer time start minute | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.11 | Integer32 (0..59) | read-write | current |
| timeSummerRecEndMonth OBJECT-TYPE The recurring summer time end month. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.12 | INTEGER {january(0), february(1), march(2), april(3), may(4), june(5), july(6), august(7), september(8), october(9), november(10), december(11)} | read-write | current |
| timeSummerRecEndWeek OBJECT-TYPE The recurring summer time end week. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.13 | INTEGER {first(0), second(1), third(2), fourth(3), last(4)} | read-write | current |
| timeSummerRecEndDay OBJECT-TYPE The recurring summer time end day. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.14 | INTEGER {sunday(0), monday(1), tuesday(2), wednesday(3), thursday(4), friday(5), saturday(6)} | read-write | current |
| timeSummerRecEndHour OBJECT-TYPE The recurring summer time end hour | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.15 | Integer32 (0..23) | read-write | current |
| timeSummerRecEndMin OBJECT-TYPE The recurring summer time end minute | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.16 | Integer32 (0..59) | read-write | current |
| timeSummerFixStartMonth OBJECT-TYPE The fixed summer time start month | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.17 | INTEGER {january(0), february(1), march(2), april(3), may(4), june(5), july(6), august(7), september(8), october(9), november(10), december(11)} | read-write | current |
| timeSummerFixStartDay OBJECT-TYPE The fixed summer time start day | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.18 | Integer32 (1..31) | read-write | current |
| timeSummerFixStartHour OBJECT-TYPE The fixed summer time start hour | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.19 | Integer32 (0..23) | read-write | current |
| timeSummerFixStartMinute OBJECT-TYPE The fixed summer time start minute | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.20 | Integer32 (0..59) | read-write | current |
| timeSummerFixEndMonth OBJECT-TYPE The fixed summer time End month | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.21 | INTEGER {january(0), february(1), march(2), april(3), may(4), june(5), july(6), august(7), september(8), october(9), november(10), december(11)} | read-write | current |
| timeSummerFixEndDay OBJECT-TYPE The fixed summer time End day | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.22 | Integer32 (1..31) | read-write | current |
| timeSummerFixEndHour OBJECT-TYPE The fixed summer time End hour | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.23 | Integer32 (0..23) | read-write | current |
| timeSummerFixEndMinute OBJECT-TYPE The fixed summer time End minute | 1.3.6.1.4.1.1966.21.1.1.1.2.5.8.24 | Integer32 (0..59) | read-write | current |
| networkTimeGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9 | |||
| timeStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.1 | ContainerStatus | read-write | current |
| timeSntpMode OBJECT-TYPE The SNTP client mode. Valid modes are Disabled, Unicast, Multicast or Anycast | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.2 | INTEGER {disabled(0), unicast(1), multicast(2), anycast(3)} | read-write | current |
| timeSntpVersion OBJECT-TYPE The sntp client version. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.3 | INTEGER {version1(0), version2(1), version3(2), version4(3)} | read-write | current |
| timeSntpHost1 OBJECT-TYPE The first remote SNTP host name that the device server communicates with. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.4 | DisplayString (SIZE(0..14)) | read-write | current |
| timeSntpHost2 OBJECT-TYPE The second remote SNTP host name that the device server communicates with. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.5 | DisplayString (SIZE(0..14)) | read-write | current |
| sntpStatGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6 | |||
| sntpStatAddress OBJECT-TYPE The address of the remote SNMP host that updated the time. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.1 | DisplayString | read-only | current |
| sntpStatLastUpdate OBJECT-TYPE The time of the last update. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.2 | DisplayString | read-only | current |
| sntpStatLeapIndicator OBJECT-TYPE The leap year indicator. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.3 | INTEGER {noWarning(0), minutes61(1), minutes59(2), alarm(3)} | read-only | current |
| sntpStatVersion OBJECT-TYPE The SNTP version. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.4 | INTEGER {ipV4(3), ipv4ipv6osi(4)} | read-only | current |
| sntpStatMode OBJECT-TYPE The current SNTP mode | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.5 | INTEGER {reserved(0), symmetricActive(1), symmetricPassive(2), client(3), server(4), broadcast(5), reservedNTP(6), reserved2(7)} | read-only | current |
| sntpStatStratum OBJECT-TYPE The SNTP stratum. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.6 | Integer32 (0..15) | read-only | current |
| sntpStatRefId OBJECT-TYPE The SNTP reference ID. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.7 | Unsigned32 | read-only | current |
| sntpStatOffset OBJECT-TYPE The SNTP offset | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.6.8 | Unsigned32 | read-only | current |
| timeSntpServerAuthentication OBJECT-TYPE Specifies whether to authenticate with the ntp time server. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.7 | INTEGER {off(1), on(2)} | read-write | current |
| timeSntpKeyID OBJECT-TYPE Specifies the key ID to use for host 1 during server authentication. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.8 | INTEGER | read-write | current |
| timeSntpKeyID2 OBJECT-TYPE Specifies the key ID to use for host 2 during server authentication. | 1.3.6.1.4.1.1966.21.1.1.1.2.5.9.9 | INTEGER | read-write | current |
| mgtFilesGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.6 | |||
| mgtBootFilesGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.6.1 | |||
| bootFileStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.1.1 | ContainerStatus | read-write | current |
| fileFirmwareHost OBJECT-TYPE The host name or IP address of the server that contains the firmware file. If you use a host name, it must exist in the management module's host table or be resolved by DNS. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.1.2 | DisplayString (SIZE(0..46)) | read-write | current |
| fileFirmwareName OBJECT-TYPE The path and file name (do not use a drive letter), relative to the default path of your TFTP server software, of the update software for the management module that will be loaded when the management module is rebooted. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.1.3 | DisplayString (SIZE(0..64)) | read-write | current |
| fileConfigurationHost OBJECT-TYPE The host name or IP address of the server that contains the configuration file. If you use a host name, it must exist in the management module's host table or be resolved by DNS. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.1.4 | DisplayString (SIZE(0..46)) | read-write | current |
| fileConfigurationName OBJECT-TYPE The path and file name (do not use a drive letter), relative to the default path of your TFTP server software, of the new configuration file for the Device Server that will be loaded when the management module is rebooted. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.1.5 | DisplayString (SIZE(0..64)) | read-write | current |
| mgtfirmwareUpdatesGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2 | |||
| firmwareUpdateStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.1 | ContainerStatus | read-write | current |
| firmwareUpdateAuto OBJECT-TYPE Enable automatic updates of installed media converter modules from firmware bundle on management module.. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.2 | OnOffValue | read-write | current |
| firmwareUpdateBundleVersionCm100 OBJECT-TYPE This object identifies the bundled firmware version for CM-100 modules. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.3 | DisplayString | read-only | current |
| firmwareUpdateBundleVersionCm110 OBJECT-TYPE This object identifies the bundled firmware version for CM-110 modules. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.4 | DisplayString | read-only | current |
| firmwareUpdateBundleVersionCm1000OrCm1000Sfp OBJECT-TYPE This object identifies the bundled firmware version for CM-1000 or CM-1000-SFP modules. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.5 | DisplayString | read-only | current |
| firmwareUpdateBundleVersionCm1110 OBJECT-TYPE This object identifies the bundled firmware version for CM-1110 modules. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.6 | DisplayString | read-only | current |
| firmwareUpdateBundleVersionCm1110Sfp OBJECT-TYPE This object identifies the bundled firmware version for CM-1110-SFP modules. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.7 | DisplayString | read-only | current |
| firmwareUpdateBundleVersionCm100mm OBJECT-TYPE This object identifies the bundled firmware version for CM-100MM modules. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.8 | DisplayString | read-only | current |
| firmwareUpdateBundleVersionCm1000mm OBJECT-TYPE This object identifies the bundled firmware version for CM-1000MM modules. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.9 | DisplayString | read-only | current |
| firmwareUpdateBundleVersionCm10g OBJECT-TYPE This object identifies the bundled firmware version for CM-10G modules. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.2.10 | DisplayString | read-only | current |
| nettxfrTable OBJECT-TYPE Table of snmp file transfer sessions. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3 | not-accessible | current | |
| nettxfrEntry OBJECT-TYPE Entries of the table, each relating to a SNMP file transfer session. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1 | not-accessible | current | |
| nettxfrSessionID OBJECT-TYPE This indicates if the net transfer is to be loaded to the management module or saved from the management module. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.1 | Unsigned32 | not-accessible | current |
| nettxfrStatus OBJECT-TYPE This field indicates the status of the nettxfr process. A value of start(1) should be written to this field to start the nettxfr process with the specified parameters in the rest of this group. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.2 | INTEGER {fileNotFound(-3), busy(-2), error(-1), idle(0), start(1), transferringFile(2), erassingFlash(3), programmingFlash(4), verifyingFlash(5), moduleReset(6), processingScriptFile(7), finished(8)} | read-write | current |
| nettxfrDirection OBJECT-TYPE This indicates if the net transfer is to be loaded to the management module or saved from the management module. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.3 | INTEGER {load(0), save(1)} | read-write | current |
| nettxfrFileType OBJECT-TYPE This indicates the type of file to be transfered to/from the management module. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.4 | INTEGER {configuration(0), firmware(1), media-converter(2), script(3), serialt-buf(4), ssh-server(5), ssl(6), text-config(7), diagnostic-file(8), sntp-keys(9)} | read-write | current |
| nettxfrFileHost OBJECT-TYPE The host name or IP address of the server that contains the file to be transfered to/from the management module.. If you use a host name, it must exist in the management module's host table or be resolved by DNS. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.5 | DisplayString (SIZE(0..46)) | read-write | current |
| nettxfrFileName OBJECT-TYPE The path and file name (do not use a drive letter), relative to the default path of your TFTP server software, of the file to be transfered to/from the management module. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.6 | DisplayString (SIZE(0..64)) | read-write | current |
| nettxfrMCSlotNumber OBJECT-TYPE Specifies the slot number of the Media Converter Module to which the firmware will be transfered. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.7 | SlotNumber | read-write | current |
| nettxfrUserName OBJECT-TYPE Specifies the user login name who owns the ssh public key that is to be transfered to the management module. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.8 | DisplayString (SIZE(0..64)) | read-write | current |
| nettxfrSSHKeyType OBJECT-TYPE Specifies the authentication method used by the ssh-server public key that is to be transfered to/from the management module | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.9 | INTEGER {dsa(0), rsa(1)} | read-write | current |
| nettxfrSSLType OBJECT-TYPE Specifies the type of SSL file to be transfered to the management module. These files are needed if you are using the secure version of the WebManager (HTTPS), or LDAP authentication with TLS. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.10 | INTEGER {ca-list(0), certificate(1), private-key(2)} | read-write | current |
| nettxfrSessionInUse OBJECT-TYPE Specifies whether this net transfer session entry is in use. If a manager tries to write a 1 to this field and the session is already in use, then an error is returned. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.11 | INTEGER {idle(0), in-use(1)} | read-write | current |
| nettxfrTftpPort OBJECT-TYPE Specifies a UDP port number for the TFTP host server. Default is 69. | 1.3.6.1.4.1.1966.21.1.1.1.2.6.3.1.12 | Unsigned32 (1..65536) | read-write | current |
| mgtAdminGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.7 | |||
| adminFunction OBJECT-TYPE Perform a specific function on the management module. If you want to save all the changes that have been submitted to the management module, you need to expand the adminGroup container folder and SET the adminFunction to 1 to write to FLASH. To make the configuration changes take effect, SET the adminFunction to 3 to reboot the management module. | 1.3.6.1.4.1.1966.21.1.1.1.2.7.1 | INTEGER {writeToFlash(1), resetToFactoryDefaults(2), reboot(3), resetSecurIDNodeSecret(4)} | read-write | current |
| adminLastFunction OBJECT-TYPE The last function requested | 1.3.6.1.4.1.1966.21.1.1.1.2.7.2 | INTEGER {writeToFlash(1), resetToFactoryDefaults(2), reboot(3), resetSecurIDNodeSecret(4)} | read-only | current |
| adminStatus OBJECT-TYPE The status of the last function performed. | 1.3.6.1.4.1.1966.21.1.1.1.2.7.3 | INTEGER {successful(0), error(1), inProgress(2)} | read-only | current |
| adminbootReason OBJECT-TYPE The reason(s) why the management module last rebooted. | 1.3.6.1.4.1.1966.21.1.1.1.2.7.4 | Bits {bootCrash(29), bootWarmStart(30), bootNormal(31)} | read-only | current |
| adminDiagFileAvailable OBJECT-TYPE This object indicates that a diagnostic file is available. | 1.3.6.1.4.1.1966.21.1.1.1.2.7.5 | YesNoValue | read-only | current |
| mgtDisplayFormatGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.8 | |||
| displayFormatStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.8.1 | ContainerStatus | read-write | current |
| cfgTemperatureUnits OBJECT-TYPE This object identifies the units to display any internally measured temperature. The units can be Celsius or Fahrenheit. | 1.3.6.1.4.1.1966.21.1.1.1.2.8.2 | INTEGER {celsius(0), fahrenheit(1)} | read-write | current |
| cfgSfpPowerUnits OBJECT-TYPE This object identifies the units to display any SFP DMI internally measured transmit/receive power. The units can be milliwatts (mW) or Decibel milliwatts (dBm). | 1.3.6.1.4.1.1966.21.1.1.1.2.8.3 | INTEGER {milliwats(0), decibelmilliwatts(1)} | read-write | current |
| cfgTimeFormat OBJECT-TYPE This object identifies the format to display the time. | 1.3.6.1.4.1.1966.21.1.1.1.2.8.4 | INTEGER {time12HourFmt(0), time24HourFmt(1)} | read-write | current |
| cfgDateFormat OBJECT-TYPE This object identifies the format to display date. | 1.3.6.1.4.1.1966.21.1.1.1.2.8.5 | INTEGER {dateMonthDayYearFmt(0), dateDayMonthYearFmt(1), dateYearMonthDayFmt(2)} | read-write | current |
| mgtChassisCfgGroup OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.1.2.9 | |||
| mgtChassisSlotPowerScheduleTable OBJECT-TYPE Table of power schedule configuration for chassis slots. (Not applicable to 2-slot chassis.) | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1 | not-accessible | current | |
| mgtChassisSlotPowerScheduleEntry OBJECT-TYPE Entries of the table, each relating to a separate slot in a chassis. | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1 | not-accessible | current | |
| powerSchedSlotIndex OBJECT-TYPE This object identifies the chassis slot number. | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.2 | SlotNumber | not-accessible | current |
| powerSchedDayOfWeek OBJECT-TYPE This object identifies the day of the week. | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.3 | INTEGER {sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7)} | not-accessible | current |
| powerSchedConifgStatus OBJECT-TYPE When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the management module. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the management module and verified. To save the changes to flash a write of writeToFlash(1) in the adminFunction object is required. 6-Indicates that the changes in the container folder are to be discarded. | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.4 | ContainerStatus | read-write | current |
| powerSchedOnHour OBJECT-TYPE This object identifies the hour (0-23) of the day to schedule a power on of the chassis slot | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.5 | INTEGER (0..23) | read-write | current |
| powerSchedOnMinute OBJECT-TYPE This object identifies the minute (0-59) of the hour to schedule a power on of the chassis slot | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.6 | INTEGER (0..59) | read-write | current |
| powerSchedOffHour OBJECT-TYPE This object identifies the hour (0-23) of the day to schedule a power off of the chassis slot | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.7 | INTEGER (0..23) | read-write | current |
| powerSchedOffMinute OBJECT-TYPE This object identifies the minute (0-59) of the hour to schedule a power off of the chassis slot | 1.3.6.1.4.1.1966.21.1.1.1.2.9.1.1.8 | INTEGER (0..59) | read-write | current |
| mcrMGTMIBConformance OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.2 | |||
| mcrMGTMIBCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.2.1 | |||
| mcrMGTMIBGroups OBJECT-IDENTITY | 1.3.6.1.4.1.1966.21.1.1.2.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| mcrMgtModuleInserted NOTIFICATION-TYPE Trap being sent indicates that a management module has been inserted int the chassis. | 1.3.6.1.4.1.1966.21.1.1.0.1 | current |
| mcrMgtSystemBoot NOTIFICATION-TYPE Trap being sent indicates that the management module's system firmware is being booted up and has completed system initialization. In some case this alert will indicate a cold start like a user resetting the management module or warm start if the module automatically resets because of a detected crash. | 1.3.6.1.4.1.1966.21.1.1.0.2 | current |
| mcrMgtReset NOTIFICATION-TYPE Trap being sent indicates that the management module has been manually reset via the reset button or one of the managers. | 1.3.6.1.4.1.1966.21.1.1.0.3 | current |
| mcrMgtResetFactory NOTIFICATION-TYPE Trap being sent indicates that the management module has been manually reset to factory by holding the reset button for 3 or more seconds, or one of the managers. This means that any files downloaded to the management module will be erase and the management configuration file is reset back to the default configuration. | 1.3.6.1.4.1.1966.21.1.1.0.4 | current |
| mcrMgtEtheLinkUp NOTIFICATION-TYPE Trap being sent indicates that the current link status of the Ethernet port on the management module is up. | 1.3.6.1.4.1.1966.21.1.1.0.5 | current |
| mcrMgtEtheLinkDown NOTIFICATION-TYPE Trap being sent indicates that the current link status of the Ethernet port on the management module is down. | 1.3.6.1.4.1.1966.21.1.1.0.6 | current |
| mcrMgtConMonDSRSigChg NOTIFICATION-TYPE Trap being sent indicates that monitor console DSR is configured and the status of one of these signal has changed on the console port. | 1.3.6.1.4.1.1966.21.1.1.0.7 | current |
| mcrMgtAuthFail NOTIFICATION-TYPE Trap being sent indicates that a user failed authentication via Telnet, SSH, WebManager, SNMP or the serial console. | 1.3.6.1.4.1.1966.21.1.1.0.8 | current |
| mcrMgtAuthSuccess NOTIFICATION-TYPE Trap being sent indicates that a user failed authentication via Telnet, SSH, WebManager or the serial console. | 1.3.6.1.4.1.1966.21.1.1.0.9 | current |
| mcrMgtDateTimeChg NOTIFICATION-TYPE Trap being sent indicates that the system date and/or time has been changed. | 1.3.6.1.4.1.1966.21.1.1.0.10 | current |
| mcrMgtSntpServFail NOTIFICATION-TYPE Trap being sent indicates that SNTP is configured and the management module can not communicate with the configured SNTP server. | 1.3.6.1.4.1.1966.21.1.1.0.11 | current |
| mcrMgtSntpServRec NOTIFICATION-TYPE Trap being sent indicates that the SNTP is configured and the management module has recovered communications with the configured SNTP server. | 1.3.6.1.4.1.1966.21.1.1.0.12 | current |
| mcrMgtSnmpTrapHostFail NOTIFICATION-TYPE Trap being sent indicates that SNMP traps is and the management module can not communicate with the configured SNMP trap host. This trap will only be sent for SNMP trap hosts configured for 'Inform' type traps. | 1.3.6.1.4.1.1966.21.1.1.0.13 | current |
| mcrMgtSnmpTrapHostRec NOTIFICATION-TYPE Trap being sent indicates that SNMP traps is and the management module has recovered communications with the configured SNMP trap host. | 1.3.6.1.4.1.1966.21.1.1.0.14 | current |
| mcrMgtEmailServFail NOTIFICATION-TYPE Trap being sent indicates that an alert email server is configured and the management module can not communicate with the configured email server. | 1.3.6.1.4.1.1966.21.1.1.0.15 | current |
| mcrMgtEmailServRec NOTIFICATION-TYPE Trap being sent indicates that an alert email server is configured and the management module has recovered communications with the configured email server. | 1.3.6.1.4.1.1966.21.1.1.0.16 | current |
| mcrMgtConfSavedFlash NOTIFICATION-TYPE Trap being sent indicates that the configuration has been saved to flash on the management module. | 1.3.6.1.4.1.1966.21.1.1.0.17 | current |
| mcrMgtIpAddrDynChg NOTIFICATION-TYPE Trap being sent indicates that the system IP address has been dynamically changed. | 1.3.6.1.4.1.1966.21.1.1.0.18 | current |
| mcrMgtTftpUploadFail NOTIFICATION-TYPE Trap being sent indicates that an attempt to transfer a file via TFTP, off the management module to a remote host has failed. | 1.3.6.1.4.1.1966.21.1.1.0.19 | current |
| mcrMgtTftpUploadSuccess NOTIFICATION-TYPE Trap being sent indicates that an attempt to transfer a file via TFTP, off the management module to a remote host was successful. | 1.3.6.1.4.1.1966.21.1.1.0.20 | current |
| mcrMgtTftpDownloadFail NOTIFICATION-TYPE Trap being sent indicates that an attempt to transfer a file via TFTP, from a remote host to the management module has failed. | 1.3.6.1.4.1.1966.21.1.1.0.21 | current |
| mcrMgtTftpDownloadSuccess NOTIFICATION-TYPE Trap being sent indicates that an attempt to transfer a file via TFTP, from a remote host to the management module was successful. | 1.3.6.1.4.1.1966.21.1.1.0.22 | current |
| mcrMgtChassisMismatch NOTIFICATION-TYPE Trap being sent indicates that the management module has been inserted into a chassis that does not match it's Backup media converter module configuration. Backup media module configurations will be reset to factory default. | 1.3.6.1.4.1.1966.21.1.1.0.23 | current |
| mcrChassisAdd NOTIFICATION-TYPE Trap being sent indicates that a new chassis as been added to the chain of chassis. | 1.3.6.1.4.1.1966.21.1.1.0.24 | current |
| mcrChassisRemove NOTIFICATION-TYPE Trap being sent indicates that that a chassis has been removed from the chain of chassis. | 1.3.6.1.4.1.1966.21.1.1.0.25 | current |
| mcrChassisReset NOTIFICATION-TYPE Trap being sent indicates that the chassis back-plane has been manually reset by a user managing the unit. | 1.3.6.1.4.1.1966.21.1.1.0.26 | current |
| mcrChassisTemperatureAlarm NOTIFICATION-TYPE Trap being sent indicates that the chassis temperature has exceeded the configured high temperature threshold temperature. | 1.3.6.1.4.1.1966.21.1.1.0.27 | current |
| mcrChassisTemperatureRecover NOTIFICATION-TYPE Trap being sent indicates that the chassis temperature has recovered back to normal operating temperature. | 1.3.6.1.4.1.1966.21.1.1.0.28 | current |
| mcrChassisSlotPoweredOn NOTIFICATION-TYPE Trap being sent indicates that the chassis slot has been powered off either manually or through the configured chassis slot power schedule. | 1.3.6.1.4.1.1966.21.1.1.0.29 | current |
| mcrChassisSlotPoweredOff NOTIFICATION-TYPE Trap being sent indicates that the chassis slot has been powered on either manually or through the configured chassis slot power schedule. | 1.3.6.1.4.1.1966.21.1.1.0.30 | current |
| mcrChassisFail NOTIFICATION-TYPE Trap being sent indicates that the management module has detected a failure condition in the chassis. | 1.3.6.1.4.1.1966.21.1.1.0.31 | current |
| mcrChassisOk NOTIFICATION-TYPE Trap being sent indicates that the chassis has recovered from a failure and is now operating normally. | 1.3.6.1.4.1.1966.21.1.1.0.32 | current |
| mcrPsmuInserted NOTIFICATION-TYPE Trap being sent indicates that a power supply has been inserted into the chassis. | 1.3.6.1.4.1.1966.21.1.1.0.33 | current |
| mcrPsmuRemoved NOTIFICATION-TYPE Trap being sent indicates that a power supply's has been removed from the chassis. | 1.3.6.1.4.1.1966.21.1.1.0.34 | current |
| mcrPsmuPsuFail NOTIFICATION-TYPE Trap being sent indicates that the power supply has failed it's self-test diagnostics. | 1.3.6.1.4.1.1966.21.1.1.0.35 | current |
| mcrPsmuPsuOk NOTIFICATION-TYPE Trap being sent indicates that the power supply has passed it's self-test diagnostics. | 1.3.6.1.4.1.1966.21.1.1.0.36 | current |
| mcrPsmuPsuVoltageFail NOTIFICATION-TYPE Trap being sent indicates that the voltage being supplied by the indicated power supply is insufficient. | 1.3.6.1.4.1.1966.21.1.1.0.37 | current |
| mcrPsmuPsuVoltageOk NOTIFICATION-TYPE Trap being sent indicates that the voltage being supplied by the indicated power supply is now in the normal operating range. | 1.3.6.1.4.1.1966.21.1.1.0.38 | current |
| mcrPsmuFanFail NOTIFICATION-TYPE Trap being sent indicates that the fan has failed. | 1.3.6.1.4.1.1966.21.1.1.0.39 | current |
| mcrPsmuFanOk NOTIFICATION-TYPE Trap being sent indicates that the fan currently operating normally. | 1.3.6.1.4.1.1966.21.1.1.0.40 | current |
| mcrMediaInserted NOTIFICATION-TYPE Trap being sent indicates that a media converter module has been inserted into the chassis. | 1.3.6.1.4.1.1966.21.1.1.0.42 | current |
| mcrMediaRemoved NOTIFICATION-TYPE Trap being sent indicates that a media converter module has been removed from the chassis. | 1.3.6.1.4.1.1966.21.1.1.0.43 | current |
| mcrMediaReset NOTIFICATION-TYPE Trap being sent indicates that the media converter module has been manually reset by a user managing the unit. | 1.3.6.1.4.1.1966.21.1.1.0.44 | current |
| mcrMediaLostCommunication NOTIFICATION-TYPE Trap being sent indicates that the management module can no longer communicate with the media converter module | 1.3.6.1.4.1.1966.21.1.1.0.45 | current |
| mcrMediaRecovCommunication NOTIFICATION-TYPE Trap being sent indicates that the management module recovered communication with a media converter module | 1.3.6.1.4.1.1966.21.1.1.0.46 | current |
| mcrMediaFail NOTIFICATION-TYPE Trap being sent indicates that the media converter module has failed its self-test diagnostics | 1.3.6.1.4.1.1966.21.1.1.0.47 | current |
| mcrMediaOk NOTIFICATION-TYPE Trap being sent indicates that the media converter module has passed its self-test diagnostics | 1.3.6.1.4.1.1966.21.1.1.0.48 | current |
| mcrMediaLinkUp NOTIFICATION-TYPE Trap being sent indicates that the current link status of the Fiber or Copper port on the media converter module is up. | 1.3.6.1.4.1.1966.21.1.1.0.49 | current |
| mcrMediaLinkDown NOTIFICATION-TYPE Trap being sent indicates that the current link status of the Fiber or Copper port on the media converter module is down. | 1.3.6.1.4.1.1966.21.1.1.0.50 | current |
| mcrMediaConfUpdateFail NOTIFICATION-TYPE Trap being sent indicates that the configuration update on the media converter module has failed. | 1.3.6.1.4.1.1966.21.1.1.0.51 | current |
| mcrMediaConfUpdateSuccess NOTIFICATION-TYPE Trap being sent indicates that the configuration update on the media converter module was successful. The media converter module configuration can be updated manually or automatically. | 1.3.6.1.4.1.1966.21.1.1.0.52 | current |
| mcrMediaConfMismatch NOTIFICATION-TYPE Trap being sent indicates that a chassis slot is configured with Backup/Restore and the media converter module type configured for the slot does not match the media converter module type inserted into the slot. | 1.3.6.1.4.1.1966.21.1.1.0.53 | current |
| mcrMediaConfMismatchResolv NOTIFICATION-TYPE Trap being sent indicates that a user has taken action to resolved media converter module configuration mismatch | 1.3.6.1.4.1.1966.21.1.1.0.54 | current |
| mcrMediaFirmwareUpdateFail NOTIFICATION-TYPE Trap being sent indicates that an attempt to update a media converter module's firmware has Failed. | 1.3.6.1.4.1.1966.21.1.1.0.55 | current |
| mcrMediaFirmwareUpdateSuccess NOTIFICATION-TYPE Trap being sent indicates that an attempt to update a media converter module's firmware was successful. | 1.3.6.1.4.1.1966.21.1.1.0.56 | current |
| mcrSfpInserted NOTIFICATION-TYPE Trap being sent indicates that a SFP module has been inserted into a media converter module | 1.3.6.1.4.1.1966.21.1.1.0.57 | current |
| mcrSfpRemoved NOTIFICATION-TYPE Trap being sent indicates that a SFP module has been removed from a media converter module | 1.3.6.1.4.1.1966.21.1.1.0.58 | current |
| mcrSfpHighTempWarn NOTIFICATION-TYPE Trap being sent indicates that a SFP module's temperature has exceeded the high temperature warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.59 | current |
| mcrSfpHighTempWarnRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's temperature has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.60 | current |
| mcrSfpHighTempAlarm NOTIFICATION-TYPE Trap being sent indicates that a SFP module's temperature has exceeded the high temperature alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.61 | current |
| mcrSfpHighTempAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's temperature has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.62 | current |
| mcrSfpLowTempWarn NOTIFICATION-TYPE Trap being sent indicates that a SFP module's temperature has gone below the low temperature warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.63 | current |
| mcrSfpLowTempWarnRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's temperature has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.64 | current |
| mcrSfpLowTempAlarm NOTIFICATION-TYPE Trap being sent indicates that a SFP module's temperature has gone below the low temperature alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.65 | current |
| mcrSfpLowTempAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's temperature has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.66 | current |
| mcrSfpHighVoltWarn NOTIFICATION-TYPE Trap being sent indicates that a SFP module's voltage has exceeded the high voltage warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.67 | current |
| mcrSfpHighVoltWarnRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's voltage has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.68 | current |
| mcrSfpHighVoltAlarm NOTIFICATION-TYPE Trap being sent indicates that a SFP module's voltage has exceeded the high voltage alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.69 | current |
| mcrSfpHighVoltAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's voltage has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.70 | current |
| mcrSfpLowVoltWarn NOTIFICATION-TYPE Trap being sent indicates that a SFP module's voltage has gone below the low voltage warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.71 | current |
| mcrSfpLowVoltWarnRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's voltage has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.72 | current |
| mcrSfpLowVoltAlarm NOTIFICATION-TYPE Trap being sent indicates that a SFP module's voltage has gone below the low voltage alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.73 | current |
| mcrSfpLowVoltAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's voltage has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.74 | current |
| mcrSfpHighTxBiasWarn NOTIFICATION-TYPE Trap being sent indicates that a SFP module's TX Bias current has exceeded the high TX Bias current warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.75 | current |
| mcrSfpHighTxBiasWarnRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's TX Bias current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.76 | current |
| mcrSfpHighTxBiasAlarm NOTIFICATION-TYPE Trap being sent indicates that a SFP module's TX Bias current has exceeded the high TX Bias current alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.77 | current |
| mcrSfpHighTxBiasAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's TX Bias current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.78 | current |
| mcrSfpLowTxBiasWarn NOTIFICATION-TYPE Trap being sent indicates that a SFP module's TX Bias current has gone below the low Tx Bias current warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.79 | current |
| mcrSfpLowTxBiasWarnRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's TX Bias current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.80 | current |
| mcrSfpLowTxBiasAlarm NOTIFICATION-TYPE Trap being sent indicates that a SFP module's TX Bias current has gone below the low Tx Bias current alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.81 | current |
| mcrSfpLowTxBiasAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's TX Bias current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.82 | current |
| mcrSfpHighTxPowerWarn NOTIFICATION-TYPE Trap being sent indicates that a SFP module's TX power has exceeded the high TX power warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.83 | current |
| mcrSfpHighTxPowerWarnRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's TX power has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.84 | current |
| mcrSfpHighTxPowerAlarm NOTIFICATION-TYPE Trap being sent indicates that a SFP module's TX power has exceeded the high TX power alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.85 | current |
| mcrSfpHighTxPowerAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's TX power has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.86 | current |
| mcrSfpLowTxPowerWarn NOTIFICATION-TYPE Trap being sent indicates that a SFP module's TX power has gone below the low TX power warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.87 | current |
| mcrSfpLowTxPowerWarnRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's TX power has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.88 | current |
| mcrSfpLowTxPowerAlarm NOTIFICATION-TYPE Trap being sent indicates that a SFP module's TX power has gone below the low TX power alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.89 | current |
| mcrSfpLowTxPowerAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's TX power has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.90 | current |
| mcrSfpHighRxPowerWarn NOTIFICATION-TYPE Trap being sent indicates that a SFP module's RX power has exceeded the high RX power warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.91 | current |
| mcrSfpHighRxPowerWarnRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's RX power has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.92 | current |
| mcrSfpHighRxPowerAlarm NOTIFICATION-TYPE Trap being sent indicates that a SFP module's RX power has exceeded the high RX power alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.93 | current |
| mcrSfpHighRxPowerAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's RX power has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.94 | current |
| mcrSfpLowRxPowerWarn NOTIFICATION-TYPE Trap being sent indicates that a SFP module's RX power has gone below the low RX power warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.95 | current |
| mcrSfpLowRxPowerWarnRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's RX power has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.96 | current |
| mcrSfpLowRxPowerAlarm NOTIFICATION-TYPE Trap being sent indicates that a SFP module's RX power has gone below the low RX power alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.97 | current |
| mcrSfpLowRxPowerAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that a SFP module's RX power has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.98 | current |
| mcrChassisCommTempSensorFail NOTIFICATION-TYPE Trap being sent indicates that communication with the chassis temperature sensor has failed. The current chassis temperature reading will be unknown | 1.3.6.1.4.1.1966.21.1.1.0.99 | current |
| mcrChassisCommTempSensorRecov NOTIFICATION-TYPE Trap being sent indicates that communication with the chassis temperature sensor has recovered. | 1.3.6.1.4.1.1966.21.1.1.0.100 | current |
| mcrMediaDetectFail NOTIFICATION-TYPE Trap being sent indicates that the indicated media card is being powered down due to the detection of a hardware failure. | 1.3.6.1.4.1.1966.21.1.1.0.101 | current |
| mcrMediaBadImage NOTIFICATION-TYPE Trap being sent indicates that the CRC of the media converter module firmware is incorrect. This can be caused if there is no image on the module or the image is corrupt. | 1.3.6.1.4.1.1966.21.1.1.0.102 | current |
| mcrSfpLostComm NOTIFICATION-TYPE Trap being sent indicates that the media converter module's microcode can no longer communicate with the SFP module. | 1.3.6.1.4.1.1966.21.1.1.0.103 | current |
| mcrSfpRecovComm NOTIFICATION-TYPE Trap being sent indicates that the media converter module's microcode had previously lost communication with, but has now regained communication with the SFP module. | 1.3.6.1.4.1.1966.21.1.1.0.104 | current |
| mcrModuleNotSupported NOTIFICATION-TYPE Trap being sent indicates that the media converter module is not fully supported by the management module. Update the management module firmware to rectify this issue. | 1.3.6.1.4.1.1966.21.1.1.0.105 | current |
| mcrModuleFirmwareUpdate NOTIFICATION-TYPE Trap being sent indicates that the media converter module firmware is being updated. | 1.3.6.1.4.1.1966.21.1.1.0.106 | current |
| mcrSfpPortShutdown NOTIFICATION-TYPE Trap being sent indicates that the Sfp/Xfp port has been shutdown due to high temperature. | 1.3.6.1.4.1.1966.21.1.1.0.107 | current |
| mcrSfpPortShutdownRecov NOTIFICATION-TYPE Trap being sent indicates that the Sfp/Xfp port shutdown has recovered. | 1.3.6.1.4.1.1966.21.1.1.0.108 | current |
| mcrXfpHighApdBiasWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's APD Bias Current has exceeded the high APD Bias warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.109 | current |
| mcrXfpHighApdBiasWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's APD Bias Current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.110 | current |
| mcrXfpHighApdBiasAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's APD Bias Current has exceeded the high APD Bias alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.111 | current |
| mcrXfpHighApdBiasAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's APD Bias Current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.112 | current |
| mcrXfpLowApdBiasWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's APD Bias Current has gone below the low APD Bias warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.113 | current |
| mcrXfpLowApdBiasWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's APD Bias Current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.114 | current |
| mcrXfpLowApdBiasAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's APD Bias Current has gone below the low APD Bias alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.115 | current |
| mcrXfpLowApdBiasAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's APD Bias Current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.116 | current |
| mcrXfpHighTecCurrentWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's TEC Current has exceeded the high TEC Current warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.117 | current |
| mcrXfpHighTecCurrentWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's TEC Current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.118 | current |
| mcrXfpHighTecCurrentAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's TEC Current has exceeded the high TEC Current alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.119 | current |
| mcrXfpHighTecCurrentAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's TEC Current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.120 | current |
| mcrXfpLowTecCurrentWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's TEC Current has gone below the low TEC Current warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.121 | current |
| mcrXfpLowTecCurrentWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's TEC Current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.122 | current |
| mcrXfpLowTecCurrentAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's TEC Current has gone below the low TEC Current alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.123 | current |
| mcrXfpLowTecCurrentAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's TEC Current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.124 | current |
| mcrXfpHighLaserTempWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's Laser Temperature has exceeded the high Laser Temperature warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.125 | current |
| mcrXfpHighLaserTempWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's Laser Temperature has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.126 | current |
| mcrXfpHighLaserTempAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's Laser Temperature has exceeded the high Laser Temperature alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.127 | current |
| mcrXfpHighLaserTempAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's Laser Temperature has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.128 | current |
| mcrXfpLowLaserTempWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's Laser Temperature has gone below the low Laser Temperature warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.129 | current |
| mcrXfpLowLaserTempWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's Laser Temperature has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.130 | current |
| mcrXfpLowLaserTempAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's Laser Temperature has gone below the low Laser Temperature alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.131 | current |
| mcrXfpLowLaserTempAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's Laser Temperature has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.132 | current |
| mcrXfpHighLaserWavelengthWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's Laser Wavelength has exceeded the high Laser Wavelength warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.133 | current |
| mcrXfpHighLaserWavelengthWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's Laser Wavelength has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.134 | current |
| mcrXfpHighLaserWavelengthAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's Laser Wavelength has exceeded the high Laser Wavelength alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.135 | current |
| mcrXfpHighLaserWavelengthAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's Laser Wavelength has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.136 | current |
| mcrXfpLowLaserWavelengthWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's Laser Wavelength has gone below the low Laser Wavelength warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.137 | current |
| mcrXfpLowLaserWavelengthWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's Laser Wavelength has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.138 | current |
| mcrXfpLowLaserWavelengthAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's Laser Wavelength has gone below the low Laser Wavelength alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.139 | current |
| mcrXfpLowLaserWavelengthAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's Laser Wavelength has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.140 | current |
| mcrXfpHigh5VoltWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply has exceeded the high +5v supply warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.141 | current |
| mcrXfpHigh5VoltWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.142 | current |
| mcrXfpHigh5VoltAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply has exceeded the high +5v supply alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.143 | current |
| mcrXfpHigh5VoltAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.144 | current |
| mcrXfpLow5VoltWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply has gone below the low +5v supply warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.145 | current |
| mcrXfpLow5VoltWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.146 | current |
| mcrXfpLow5VoltAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply has gone below the low +5v supply alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.147 | current |
| mcrXfpLow5VoltAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.148 | current |
| mcrXfpHigh33VoltWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply has exceeded the high +3.3v supply warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.149 | current |
| mcrXfpHigh33VoltWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.150 | current |
| mcrXfpHigh33VoltAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply has exceeded the high +3.3v supply alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.151 | current |
| mcrXfpHigh33VoltAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.152 | current |
| mcrXfpLow33VoltWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply has gone below the low +3.3v supply warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.153 | current |
| mcrXfpLow33VoltWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.154 | current |
| mcrXfpLow33VoltAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply has gone below the low +3.3v supply alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.155 | current |
| mcrXfpLow33VoltAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.156 | current |
| mcrXfpHigh18VoltWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply has exceeded the high +1.8v supply warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.157 | current |
| mcrXfpHigh18VoltWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.158 | current |
| mcrXfpHigh18VoltAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply has exceeded the high +1.8v supply alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.159 | current |
| mcrXfpHigh18VoltAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.160 | current |
| mcrXfpLow18VoltWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply has gone below the low +1.8v supply warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.161 | current |
| mcrXfpLow18VoltWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.162 | current |
| mcrXfpLow18VoltAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply has gone below the low +1.8v supply alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.163 | current |
| mcrXfpLow18VoltAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.164 | current |
| mcrXfpHighM52VoltWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply has exceeded the high -5.2v supply warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.165 | current |
| mcrXfpHighM52VoltWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.166 | current |
| mcrXfpHighM52VoltAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply has exceeded the high -5.2v supply alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.167 | current |
| mcrXfpHighM52VoltAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.168 | current |
| mcrXfpLowM52VoltWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply has gone below the low -5.2v supply warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.169 | current |
| mcrXfpLowM52VoltWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.170 | current |
| mcrXfpLowM52VoltAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply has gone below the low -5.2v supply alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.171 | current |
| mcrXfpLowM52VoltAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.172 | current |
| mcrXfpHigh5VCurrentWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply current has exceeded the high +5v supply current warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.173 | current |
| mcrXfpHigh5VCurrentWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.174 | current |
| mcrXfpHigh5VCurrentAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply current has exceeded the high +5v supply current alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.175 | current |
| mcrXfpHigh5VCurrentAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.176 | current |
| mcrXfpLow5VCurrentWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply current has gone below the low +5v supply current warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.177 | current |
| mcrXfpLow5VCurrentWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.178 | current |
| mcrXfpLow5VCurrentAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply current has gone below the low +5v supply current alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.179 | current |
| mcrXfpLow5VCurrentAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.180 | current |
| mcrXfpHigh33VCurrentWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply current has exceeded the high +3.3v supply current warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.181 | current |
| mcrXfpHigh33VCurrentWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.182 | current |
| mcrXfpHigh33VCurrentAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply current has exceeded the high +3.3v supply current alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.183 | current |
| mcrXfpHigh33VCurrentAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.184 | current |
| mcrXfpLow33VCurrentWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply current has gone below the low +3.3v supply current warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.185 | current |
| mcrXfpLow33VCurrentWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.186 | current |
| mcrXfpLow33VCurrentAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply current has gone below the low +3.3v supply current alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.187 | current |
| mcrXfpLow33VCurrentAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.188 | current |
| mcrXfpHigh18VCurrentWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply current has exceeded the high +1.8v supply current warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.189 | current |
| mcrXfpHigh18VCurrentWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.190 | current |
| mcrXfpHigh18VCurrentAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply current has exceeded the high +1.8v supply current alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.191 | current |
| mcrXfpHigh18VCurrentAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.192 | current |
| mcrXfpLow18VCurrentWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply current has gone below the low +1.8v supply current warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.193 | current |
| mcrXfpLow18VCurrentWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.194 | current |
| mcrXfpLow18VCurrentAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply current has gone below the low +1.8v supply current alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.195 | current |
| mcrXfpLow18VCurrentAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.196 | current |
| mcrXfpHighM52VCurrentWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply current has exceeded the high -5.2v supply current warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.197 | current |
| mcrXfpHighM52VCurrentWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.198 | current |
| mcrXfpHighM52VCurrentAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply current has exceeded the high -5.2v supply current alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.199 | current |
| mcrXfpHighM52VCurrentAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.200 | current |
| mcrXfpLowM52VCurrentWarn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply current has gone below the low -5.2v supply current warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.201 | current |
| mcrXfpLowM52VCurrentWarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.202 | current |
| mcrXfpLowM52VCurrentAlarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply current has gone below the low -5.2v supply current alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.203 | current |
| mcrXfpLowM52VCurrentAlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply current has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.204 | current |
| mcrXfpHighVCC5Warn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply has exceeded the high +5v supply warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.205 | current |
| mcrXfpHighVCC5WarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.206 | current |
| mcrXfpHighVCC5Alarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply has exceeded the high +5v supply alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.207 | current |
| mcrXfpHighVCC5AlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.208 | current |
| mcrXfpLowVCC5Warn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply has gone below the low +5v supply warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.209 | current |
| mcrXfpLowVCC5WarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.210 | current |
| mcrXfpLowVCC5Alarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply has gone below the low +5v supply alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.211 | current |
| mcrXfpLowVCC5AlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +5v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.212 | current |
| mcrXfpHighVCC3Warn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply has exceeded the high +3.3v supply warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.213 | current |
| mcrXfpHighVCC3WarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.214 | current |
| mcrXfpHighVCC3Alarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply has exceeded the high +3.3v supply alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.215 | current |
| mcrXfpHighVCC3AlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.216 | current |
| mcrXfpLowVCC3Warn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply has gone below the low +3.3v supply warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.217 | current |
| mcrXfpLowVCC3WarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.218 | current |
| mcrXfpLowVCC3Alarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply has gone below the low +3.3v supply alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.219 | current |
| mcrXfpLowVCC3AlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +3.3v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.220 | current |
| mcrXfpHighVCC2Warn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply has exceeded the high +1.8v supply warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.221 | current |
| mcrXfpHighVCC2WarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.222 | current |
| mcrXfpHighVCC2Alarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply has exceeded the high +1.8v supply alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.223 | current |
| mcrXfpHighVCC2AlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.224 | current |
| mcrXfpLowVCC2Warn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply has gone below the low +1.8v supply warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.225 | current |
| mcrXfpLowVCC2WarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.226 | current |
| mcrXfpLowVCC2Alarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply has gone below the low +1.8v supply alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.227 | current |
| mcrXfpLowVCC2AlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's +1.8v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.228 | current |
| mcrXfpHighVEE5Warn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply has exceeded the high -5.2v supply warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.229 | current |
| mcrXfpHighVEE5WarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.230 | current |
| mcrXfpHighVEE5Alarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply has exceeded the high -5.2v supply alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.231 | current |
| mcrXfpHighVEE5AlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.232 | current |
| mcrXfpLowVEE5Warn NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply has gone below the low -5.2v supply warning threshold. | 1.3.6.1.4.1.1966.21.1.1.0.233 | current |
| mcrXfpLowVEE5WarnRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.234 | current |
| mcrXfpLowVEE5Alarm NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply has gone below the low -5.2v supply alarm threshold. | 1.3.6.1.4.1.1966.21.1.1.0.235 | current |
| mcrXfpLowVEE5AlarmRecov NOTIFICATION-TYPE Trap being sent indicates that an XFP module's -5.2v supply has recovered to normal operating level. | 1.3.6.1.4.1.1966.21.1.1.0.236 | current |
| mcrSfpSpeedMismatch NOTIFICATION-TYPE Trap being sent indicates that there is a speed mismatch between the two SFP modules installed in the media converter. | 1.3.6.1.4.1.1966.21.1.1.0.237 | current |
| mcrSfpSpeedMismatchRecov NOTIFICATION-TYPE Trap being sent indicates that the speed mismatch between the two SFP modules has recovered. | 1.3.6.1.4.1.1966.21.1.1.0.238 | current |
| mcrXfpPowerExceeded NOTIFICATION-TYPE Trap being sent indicates that an XFP module's power requirements has exceeded card capacity. | 1.3.6.1.4.1.1966.21.1.1.0.239 | current |
| mcrXfpPowerExceededRecov NOTIFICATION-TYPE Trap being sent indicates that the XFP excessive power alarm has recovered. | 1.3.6.1.4.1.1966.21.1.1.0.240 | current |
| mcrLinkTestError NOTIFICATION-TYPE Trap being sent indicates that the link test running on the media converter has detected errors. | 1.3.6.1.4.1.1966.21.1.1.0.241 | current |
| mcrAlarmRelayEngaged NOTIFICATION-TYPE Trap being sent indicates that the chassis alarm relay has engaged | 1.3.6.1.4.1.1966.21.1.1.0.242 | current |
| mcrAlarmRelayDisengaged NOTIFICATION-TYPE Trap being sent indicates that the chassis alarm relay has disengaged | 1.3.6.1.4.1.1966.21.1.1.0.243 | current |
| mcrBandwidthLevelUpstreamLow NOTIFICATION-TYPE Trap being sent indicates the media port is in a low upstream bandwidth condition. This happens when the bandwidth is below the configured threshold. | 1.3.6.1.4.1.1966.21.1.1.0.244 | current |
| mcrBandwidthLevelUpstreamRecov NOTIFICATION-TYPE Trap being sent indicates the media port has recovered from a low upstream bandwidth condition. | 1.3.6.1.4.1.1966.21.1.1.0.245 | current |
| mcrBandwidthLevelDownstreamLow NOTIFICATION-TYPE Trap being sent indicates the media port is in a low downstream bandwidth condition. This happens when the bandwidth is below the configured threshold. | 1.3.6.1.4.1.1966.21.1.1.0.246 | current |
| mcrBandwidthLevelDownstreamRecov NOTIFICATION-TYPE Trap being sent indicates the media port has recovered from a low downstream bandwidth condition. | 1.3.6.1.4.1.1966.21.1.1.0.247 | current |
| mcrMediaRemoteReset NOTIFICATION-TYPE Trap being sent indicates that the media converter module's peer has been manually reset by a user managing the unit. | 1.3.6.1.4.1.1966.21.1.1.0.248 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| mcrMGTMIBCompliance MODULE-COMPLIANCE The compliance statement for mcrMGT which implement the Perle Managed Media Converters MIB. | 1.3.6.1.4.1.1966.21.1.1.2.1.1 | current |
| mcrMGTMIBChassisGroup OBJECT-GROUP The group of objects for identifying and determining the configuration and current timeliness values of the Perle Managed Media Converters chassis. | 1.3.6.1.4.1.1966.21.1.1.2.2.1 | current |
| mcrMGTMIBMediaGroup OBJECT-GROUP The group of objects for identifying and determining the configuration and current timeliness values of the Perle Managed Media Converters media converter modules | 1.3.6.1.4.1.1966.21.1.1.2.2.2 | current |
| mcrMGTMIBMgtGroup OBJECT-GROUP The group of objects for identifying and determining the configuration and current timeliness values of the Perle Managed Media Converters media converter modules | 1.3.6.1.4.1.1966.21.1.1.2.2.3 | current |
| mcrMGTMIBNotificationsGroup NOTIFICATION-GROUP The group of notifications (traps) which is implemented for the Perle Managed Media Converters. | 1.3.6.1.4.1.1966.21.1.1.2.2.4 | current |