PEGASUS-SDH-MIB
- Registered at
- 1.3.6.1.4.1.6368.2.8
- Last updated
- 2004-03-18 00:00
- Organization
- Schmid Telecom, Zurich
- Revisions
- 2004-03-18 00:00, 2004-01-07 00:00, 2003-11-17 00:00
- Namespace
- pegasus
- Source file
PEGASUS-SDH-MIB- Digest
sha256:4c511787bf8c2860525918c4bea367e349c6019cce6e666662ca281c1611828c
Description
This MIB applies to the PEGASUS SDSL product manufactured by Schmid Telecom Zurich. The MIB is modelled after the PEM management model, so object hierarchy and individual variables agree with the PEM client. This MIB represents an extension to the DS1-MIB and the SONET-MIB. These three MIB files are used to manage the PEGASUS STM-1 card. The PEGASUS-SDH-MIB contains five tables: - stm1CardTable one entry for each STM-1 card configured. - stm1CardClockTable one entry for each STM-1 card configured. - ethernetIfTable one entry for each Ethernet interface of a configured STM-1 card. - vcTable one entry for each Virtual Container (VC-3/4/12). - tugConfigTable one entry for each Tributary Unit Group (TUG-3). Note - The tables that represent extensions to the DS1-/SINET-MIB use the ifIndex from IF-MIB (ifTable).
Contact
Schmid Telecom AG Binzstrasse 35, CH-8048 Zurich Switzerland Email: xdslsupport@schmid-telecom.ch
Imports
| From | Symbols |
|---|---|
| IF-MIB | InterfaceIndex, InterfaceIndexOrZero, ifIndex |
| PEGASUS-MIB | AvailabilityStatusElem, CommStateEnum, OperStateEnum, pegasusMibModule |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB IF-MIB PEGASUS-MIB PEGASUS-SDH-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ClockModeEnum type | ||||
| ClockPriorityEnum type | ||||
| ClockQualityEnum type | ||||
| ClockSourceEnum type | ||||
| ClockStateEnum type | ||||
| ClockSyncStateEnum type | ||||
| ConcatenationTypeEnum type | ||||
| EthernetIfEncapsulationEnum type | ||||
| LaserOperationModeEnum type | ||||
| LaserStateEnum type | ||||
| MultiplexingModeEnum type | ||||
| OrderLevelEnum type | ||||
| PRBSPatternEnum type | ||||
| STM1SlotNumber type | ||||
| SdhInterfaceEnum type | ||||
| SignalLabel TEXTUAL-CONVENTION Representation of a VC Signal Label. The meaning of the SignalLabel depends on the type of vitual container. VC-12s use the following values: 001b Unequipped 001b Equipped (non specific) 010b Asynchronous 011b Bit Synchronous 100b Byte Synchronous 101b Reserved for future use 110b Test signal (O.181) 111b VC-AIS VC-4 and VC-3 use these values: 00h Unequipped or supervisory-unequipped 01h Equipped - non-specific 02h TUG Structure 03h Locked TU-n 04h Asynch. mapping of 34'386/44'736 kbit/s into Container-3 12h Asynch. mapping of 139'264 kbit/s into Container-4 13h ATM Mapping 14h MAN DQDB (IEEE 802.6 mapping 15h FDDI (ISO 9314) mapping 16h Mapping of HDLC/PPP framed signal 17h Mapping of SDL with SDH self synch. Scrambler 18h Mapping of HDLC/LAP-S framed signals 19h Mapping of SDL with set-reset scrambler 1Ah Mapping of 10 Gbit/s Ethernet frames (IEEE 802.3) CFh Obsolete mapping of HDLC/PPP framed signal E1h-FCh Reserved for national use FEh Test signal, O.181 specific mapping FFh VC-AIS | current | |||
| TUGIndex type | ||||
| TUGIndexOrZero type | ||||
| TraceSizeEnum type | ||||
| VirtualContainerTypeEnum type |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| stm1CardTable OBJECT-TYPE A table containing stm1 card specific information. | 1.3.6.1.4.1.6368.2.8.1 | not-accessible | current | |
| stm1CardEntry OBJECT-TYPE Row and index definition for stm1 card table. | 1.3.6.1.4.1.6368.2.8.1.1 | not-accessible | current | |
| stm1CardSlotNumber OBJECT-TYPE Slot number for stm1 card. | 1.3.6.1.4.1.6368.2.8.1.1.1 | STM1SlotNumber | not-accessible | current |
| stm1CardName OBJECT-TYPE Name of the PEGASUS device. | 1.3.6.1.4.1.6368.2.8.1.1.2 | DisplayString | read-only | current |
| stm1CardHardwareVersion OBJECT-TYPE Hardware version of the STM-1 card. This is also called CHM-number (it always starts with the letters 'CHM'). The number '404' after 'CHM' identifies the card as a STM-1 card. | 1.3.6.1.4.1.6368.2.8.1.1.3 | DisplayString | read-only | current |
| stm1CardFirmwareVersion OBJECT-TYPE Version number and build date of the firmware running on the line card. The format is 'major.minor YYYYMMDD hh:mm'. | 1.3.6.1.4.1.6368.2.8.1.1.4 | DisplayString | read-only | current |
| stm1CardManufacturer OBJECT-TYPE Manufacturer of the STM-1 card. | 1.3.6.1.4.1.6368.2.8.1.1.5 | DisplayString | read-only | current |
| stm1CardSerialNumber OBJECT-TYPE Serial number of the line card. Also called HM-number, as it always starts with 'HM'. Example: HMVSS014810294. | 1.3.6.1.4.1.6368.2.8.1.1.6 | DisplayString | read-only | current |
| stm1CardMultiplexingMode OBJECT-TYPE Selects the SDH multiplexing mode. Either it is STM1-AU3-VC3 or STM1-AU4-VC4. | 1.3.6.1.4.1.6368.2.8.1.1.7 | MultiplexingModeEnum | read-write | current |
| stm1CardJ0TraceMonitoring OBJECT-TYPE If trace monitoring is disable no alarm is propagated to PEM and also no RDI/AIS is inserted. | 1.3.6.1.4.1.6368.2.8.1.1.8 | OperStateEnum | read-write | current |
| stm1CardJ1TraceMonitoring OBJECT-TYPE If trace monitoring is disable no alarm is propagated to PEM and also no RDI/AIS is inserted. | 1.3.6.1.4.1.6368.2.8.1.1.9 | OperStateEnum | read-write | current |
| stm1CardJ2TraceMonitoring OBJECT-TYPE If trace monitoring is disable no alarm is propagated to PEM and also no RDI/AIS is inserted. | 1.3.6.1.4.1.6368.2.8.1.1.10 | OperStateEnum | read-write | current |
| stm1CardJ0PathTraceSize OBJECT-TYPE Size of the Regenerator Section Trace Message. | 1.3.6.1.4.1.6368.2.8.1.1.11 | TraceSizeEnum | read-write | current |
| stm1CardJ0PathTraceSend OBJECT-TYPE Configurable Regenerator Section (RS) Trace Message. | 1.3.6.1.4.1.6368.2.8.1.1.12 | DisplayString | read-write | current |
| stm1CardJ0PathTraceExpected OBJECT-TYPE Regenerator Section (RS) Trace Message that should be received. | 1.3.6.1.4.1.6368.2.8.1.1.13 | DisplayString | read-write | current |
| stm1CardJ0PathTraceReceive OBJECT-TYPE Regenerator Section (RS) Trace Message that is be received. | 1.3.6.1.4.1.6368.2.8.1.1.14 | DisplayString | read-only | current |
| stm1CardLaserOperationMode OBJECT-TYPE Configuration of the 'Automatic Laser Shutdown' feature. | 1.3.6.1.4.1.6368.2.8.1.1.15 | LaserOperationModeEnum | read-write | current |
| stm1CardLaserState OBJECT-TYPE Actual state of the laser. | 1.3.6.1.4.1.6368.2.8.1.1.16 | LaserStateEnum | read-only | current |
| stm1CardOperState OBJECT-TYPE The operational state is a status property indicating whether or not a device is physically installed and working. enabled The device is partially or fully operable and available for use. disabled The device is totally inoperable and unavailable to provide service. | 1.3.6.1.4.1.6368.2.8.1.1.17 | OperStateEnum | read-only | current |
| stm1CardAvailabilityState OBJECT-TYPE The availability status gives more detailed information about failures within a device. An empty status set means that no error exists. Possible status are: in test The device is under test. failed The device has an internal fault that prevents it from operating. power off The device requires power to be applied and is not powered on. off line The device requires a routine operation to be performed to place it online and make it available for use. off duty The device has been made inactive by an internal control process in accordance with a predetermined time schedule. dependency The device can not operate because some other resource on which it depends is unavailable. degraded The device is partially defective but still operable. not installed The device is not present, or incomplete. log full The log is full. | 1.3.6.1.4.1.6368.2.8.1.1.18 | AvailabilityStatusElem | read-only | current |
| stm1CardMgmtCommState OBJECT-TYPE The Management Comm State indicates the state of the management connection between the PEM Server and the STM-1 card. disconnected No connection has been established. init A connection has freshly been established on the underlying protocol, but no management information has been transmitted so far. identification The connected device is being identified. check hardware The connected hardware is compared to the one stored in the configuration. hardware adaptation If the configured and the existing device do not match, an adoption is made. The behaviour in this case can be configured with the 'HW Adaptation Policy' option. check program version The program version of the connected hardware is compared to the one stored in the configuration. check config version The configuration version of the connected hardware is compared to the one stored in the configuration. download config If a configuration version mismatch has been detected and the 'Config Priority' of 'PEGASUS system' is set to 'Device', the configuration is downloaded from the device to the PEM Server. upload config If a configuration version mismatch has been detected and the 'Config Priority' of 'PEGASUS system' is set to 'Server', the configuration is uploaded from the PEM Server to the device. status synch The values of the status properties are being synchronised. resetting The device is resetting. inactive The device is connected, but it is inactive, that is not operational. This may be due to a hardware mismatch. active The management connection between the device and the PEM Server is fully established and the device is active. | 1.3.6.1.4.1.6368.2.8.1.1.19 | CommStateEnum | read-only | current |
| stm1CardPRBSGeneratorSink OBJECT-TYPE Determines, whether the PRBS Generator should be used on the optical or on the E1 links. | 1.3.6.1.4.1.6368.2.8.1.1.20 | SdhInterfaceEnum | read-write | current |
| stm1CardPRBSAnalyzerSource OBJECT-TYPE Determines, whether the PRBS Analyzer should be used on the optical or on the E1 links. | 1.3.6.1.4.1.6368.2.8.1.1.21 | SdhInterfaceEnum | read-write | current |
| stm1CardPRBSPattern OBJECT-TYPE Determines the PRBS Pattern to be used. | 1.3.6.1.4.1.6368.2.8.1.1.22 | PRBSPatternEnum | read-write | current |
| stm1CardAlarmStatus OBJECT-TYPE This variable indicates the status of STM-1 card, regenerator section and multiplex section. It's a bitmap represented as a sum. Therefore multiple alarms can be displayed simultaneously. The value noAlarm is only set if there isn't any alarm active. The various bit positions are: 1 No alarm present -- STM-1 card -- 2 Initialization failure 4 Firmware Version Mismatch 8 Maintenance -- regenerator section RS -- 16 Loss of Signal (LOS) 32 Loss of Frame (LOF) 64 Trace ID Mismatch (RS-TIM) -- multiplex section MS -- 128 Alarm Indication Signal (MS-AIS) 256 Remote Defect Indication (MS-RDI, former FERF) | 1.3.6.1.4.1.6368.2.8.1.1.23 | Integer32 (1..511) | read-only | current |
| stm1CardClockTable OBJECT-TYPE A table containing stm1 card specific clock information. | 1.3.6.1.4.1.6368.2.8.2 | not-accessible | current | |
| stm1CardClockEntry OBJECT-TYPE Row and index definition for stm1 card clock table. | 1.3.6.1.4.1.6368.2.8.2.1 | not-accessible | current | |
| stm1CardActiveClockSource OBJECT-TYPE Displays which clock sourceis active and used as sync source. | 1.3.6.1.4.1.6368.2.8.2.1.1 | ClockSourceEnum | read-only | current |
| stm1CardClockSyncState OBJECT-TYPE Sync status is OK if RX or Reference clock is valid and used as active sync source. | 1.3.6.1.4.1.6368.2.8.2.1.2 | ClockSyncStateEnum | read-only | current |
| stm1CardTxLineClockQuality OBJECT-TYPE This is the clock quality of the outgoing SDH signal. The default sets the outgoing quality to the incoming quality. Sometime it may be useful to set a fix outgoing quality. | 1.3.6.1.4.1.6368.2.8.2.1.3 | ClockQualityEnum | read-write | current |
| stm1CardRxClockMode OBJECT-TYPE If enabled the RX line clock can be used as sync source. | 1.3.6.1.4.1.6368.2.8.2.1.4 | ClockModeEnum | read-write | current |
| stm1CardRxClockPriority OBJECT-TYPE This value has always the opposite value of Reference Clock Priority. | 1.3.6.1.4.1.6368.2.8.2.1.5 | ClockPriorityEnum | read-write | current |
| stm1CardRxClockQuality OBJECT-TYPE This is the clock quality of the incoming SDH signal. | 1.3.6.1.4.1.6368.2.8.2.1.6 | ClockQualityEnum | read-only | current |
| stm1CardRxClockState OBJECT-TYPE Clock status is valid if a good clock can be found on input (clock checker). | 1.3.6.1.4.1.6368.2.8.2.1.7 | ClockStateEnum | read-only | current |
| stm1CardReferenceClockMode OBJECT-TYPE If enabled the Reference clock (V5 card input) can be used as sync source. | 1.3.6.1.4.1.6368.2.8.2.1.8 | ClockModeEnum | read-write | current |
| stm1CardReferenceClockPriority OBJECT-TYPE This value has always the opposite value of Rx Clock Priority. | 1.3.6.1.4.1.6368.2.8.2.1.9 | ClockPriorityEnum | read-write | current |
| stm1CardReferenceClockQuality OBJECT-TYPE Defines the quality of the reference clock input. This value will be transmitted in SDH-TX if reference clock is used as active sync source. | 1.3.6.1.4.1.6368.2.8.2.1.10 | ClockQualityEnum | read-write | current |
| stm1CardReferenceClockState OBJECT-TYPE Clock status is valid if a good clock can be found on input (clock checker). | 1.3.6.1.4.1.6368.2.8.2.1.11 | ClockStateEnum | read-only | current |
| ethernetIfTable OBJECT-TYPE This table contains additional information concerning the ethernet interfaces of a STM-1 card. It represents an extension of the if(X)Table (see IF-MIB). | 1.3.6.1.4.1.6368.2.8.3 | not-accessible | current | |
| ethernetIfEntry OBJECT-TYPE Row and index definition for the ethernetIfTable. | 1.3.6.1.4.1.6368.2.8.3.1 | not-accessible | current | |
| etherIfConcatenationOption OBJECT-TYPE Configuration of the Link Capacity Adjustment Scheme. | 1.3.6.1.4.1.6368.2.8.3.1.1 | ConcatenationTypeEnum | read-write | current |
| etherIfEncapsulation OBJECT-TYPE This attribute shows the used Ethernet encapsulation protocol. | 1.3.6.1.4.1.6368.2.8.3.1.2 | EthernetIfEncapsulationEnum | read-only | current |
| etherIfOrderLevel OBJECT-TYPE Only relevant, if SDH Multiplexing Mode (see STM-1 card propertied) is set to VC3. | 1.3.6.1.4.1.6368.2.8.3.1.3 | OrderLevelEnum | read-only | current |
| etherIfAlarmStatus OBJECT-TYPE This variable indicates the status of an Ethernet Interface. It's a bitmap represented as a sum. Therefore multiple defects can be displayed simultaneously. The value noAlarm is only set if there isn't any alarm. The various bit positions are (LO = LowOrder, HO = HighOrder): 1 No alarm 2 LO LCAS group identifier mismatch (Rx) 4 HO LCAS group identifier mismatch (Rx) 8 LO VCG exceeds max. differential delay (Rx) 16 HO VCG exceeds max. differential delay (Rx) 32 LO VCG exceeds max. differential delay, calculated over all containers (Rx) 64 HO VCG exceeds max. differential delay, calculated over all containers (Rx) 128 Transmit FIFO overflow (Tx) 256 Rx head-of-line blocking FIFO overflow | 1.3.6.1.4.1.6368.2.8.3.1.4 | Integer32 (1..511) | read-only | current |
| vcTable OBJECT-TYPE This table contains additional information for VC concerning the multiplexing configuration. It's an extension of the ifTable (IF-MIB) and the tables of the SONET/SDH-MIB. | 1.3.6.1.4.1.6368.2.8.4 | not-accessible | current | |
| vcEntry OBJECT-TYPE Row and index definition for the vcConfigTable. | 1.3.6.1.4.1.6368.2.8.4.1 | not-accessible | current | |
| vcType OBJECT-TYPE Type of Virtual Container (VC). In Pegasus VC-4, VC-3 or VC-12. | 1.3.6.1.4.1.6368.2.8.4.1.1 | VirtualContainerTypeEnum | read-only | current |
| vcRelatedTUG OBJECT-TYPE Represents the index of the Tributary Unit Group within the tugConfigTable to which this VC is assigned to. The value depends also on the multiplexing mode. If the value is 0, there doesn't exist the relation VC-x to TUG-3. Possible values: 1) multiplexing mode = AU-4: VC-4: vcRelatedTUG = 0 VC-3/12: vcRelatedTUG = 1..3 2) multiplexing mode = AU-3: vcRelatedTUG = 0 (no dependency on VC type) | 1.3.6.1.4.1.6368.2.8.4.1.2 | TUGIndexOrZero | read-only | current |
| vcRelatedVC OBJECT-TYPE Represents the index of the Virtual Container within the ifTable to which this VC is assigned to. The value depends also on the multiplexing mode. If the value is 0, there doesn't exist the relation VC-x to VC-x. Possible values: 1) multiplexing mode = AU-4: vcRelatedVC = 0 (no dependency on VC type) 2) multiplexing mode = AU-3: VC-3: vcRelatedVC = 0 VC-12: vcRelatedVC = 2031..2033 (example for slot 2) | 1.3.6.1.4.1.6368.2.8.4.1.3 | InterfaceIndexOrZero | read-only | current |
| vcAssignedIfIndex OBJECT-TYPE Represents the index of the interface within the ifTable (IF-MIB) that transmits to this VC. | 1.3.6.1.4.1.6368.2.8.4.1.4 | InterfaceIndexOrZero | read-write | current |
| vcPathTraceSend OBJECT-TYPE The value of the outgoing J1 Byte VC Path Trace byte message. | 1.3.6.1.4.1.6368.2.8.4.1.5 | DisplayString | read-write | current |
| vcPathTraceExpected OBJECT-TYPE The value of the expected J1 Byte VC Path Trace byte message. | 1.3.6.1.4.1.6368.2.8.4.1.6 | DisplayString | read-write | current |
| vcPathTraceReceive OBJECT-TYPE The value of the incoming J1 Byte VC Path Trace byte message. | 1.3.6.1.4.1.6368.2.8.4.1.7 | DisplayString | read-only | current |
| vcSignalLabelSend OBJECT-TYPE The outgoing C2 VC Signal Label (0x02 = TUG structure). | 1.3.6.1.4.1.6368.2.8.4.1.8 | SignalLabel | read-write | current |
| vcSignalLabelExpected OBJECT-TYPE The expected C2 VC Signal Label (0x02 = TUG structure). | 1.3.6.1.4.1.6368.2.8.4.1.9 | SignalLabel | read-write | current |
| vcSignalLabelReceive OBJECT-TYPE The incoming C2 VC Signal Label (0x02 = TUG structure). | 1.3.6.1.4.1.6368.2.8.4.1.10 | SignalLabel | read-only | current |
| vcAlarmStatus OBJECT-TYPE This variable indicates the status of the VC. It's a bitmap represented as a sum. Therefore multiple defects can be displayed simultaneously. The value noDefect should only be set if there is no other defect. Some alarms can't occur actually. The various bit positions are: 1 vcNoDefect 2 vcAlarmAIS 4 vcAlarmLOP 8 vcAlarmRDI 16 vcAlarmUnequipped 32 vcAlarmPLM 64 vcAlarmTIM 128 vcAlarmLOM 256 vcAlarmRFI 512 vcgTxAddTimeout -- not used (deprecated) 1024 vcgTxAdd -- not used (deprecated) 2048 vcgTxRemove -- not used (deprecated) 4096 vcgTxDnu -- not used (deprecated) 8192 vcgDnuOk -- not used (deprecated) 16384 vcgRxAdd -- not used (deprecated) 32768 vcgRxRemove -- not used (deprecated) 65536 vcgRxFail -- not used (deprecated) 131072 vcgLcasCrcError 262144 vcgNonLcasSeqError | 1.3.6.1.4.1.6368.2.8.4.1.11 | Integer32 (1..524287) | read-only | current |
| tugConfigTable OBJECT-TYPE This table contains information concerning Tributary Unit Groups. If AU-3 structure is used, this table is empty. | 1.3.6.1.4.1.6368.2.8.5 | not-accessible | current | |
| tugConfigEntry OBJECT-TYPE Row and index definition for the tugConfigTable. | 1.3.6.1.4.1.6368.2.8.5.1 | not-accessible | current | |
| tugIndex OBJECT-TYPE Number of the TUG. Range 1..3 | 1.3.6.1.4.1.6368.2.8.5.1.1 | TUGIndex | not-accessible | current |
| tugRelatedVC4 OBJECT-TYPE | 1.3.6.1.4.1.6368.2.8.5.1.2 | InterfaceIndex | read-only | current |
| tugOrderLevel OBJECT-TYPE Individual Order Level of this TUG. If high order is used, the TUG has exactly one VC-3 and no VC-12s. If low order is used, the TUG has exactly 21 VC-12 and no VC-3. | 1.3.6.1.4.1.6368.2.8.5.1.3 | OrderLevelEnum | read-write | current |
| sdhMibRevision OBJECT-TYPE The version number assigned by the version control system. You can query this from the agent, to find out with which version of the MIB was built into the agent. The value is also present in copies of the MIB to feed into SNMP managers. Comparing the version numbers from both sources can help to detect mismatches. The revision string for this version is: $Workfile: PEGASUS-SDH-MIB.txt $ $Revision: 14 $ $Date: 3/18/04 6:40p $ | 1.3.6.1.4.1.6368.2.8.6 | DisplayString | read-only | current |