2016-02-22 00:00, 2016-02-03 00:00, 2015-11-02 00:00, 2015-10-26 00:00, 2015-10-16 00:00, 2015-10-02 00:00, 2015-06-19 00:00, 2015-03-11 00:00, 2014-04-03 00:00, 2012-03-22 00:00, 2012-03-15 00:00, 2012-03-14 00:00, 2011-11-30 00:00, 2011-11-07 00:00, 2011-10-06 00:00, 2011-05-17 00:00, 2011-05-11 00:00, 2011-04-18 00:00, 2011-02-14 00:00, 2011-01-24 00:00, 2010-11-30 00:00, 2010-11-04 00:00, 2010-07-21 00:00, 2010-07-19 00:00, 2010-07-15 00:00, 2010-07-13 00:00, 2010-06-29 00:00, 2010-06-07 00:00, 2010-05-27 00:00, 2010-05-20 00:00, 2010-05-17 00:00, 2009-06-09 00:00, 2009-04-20 00:00, 2009-02-13 00:00, 2009-02-12 00:00, 2008-12-01 00:00, 2008-10-24 00:00, 2008-09-25 00:00, 2008-09-05 00:00, 2008-06-05 00:00, 2007-11-28 00:00, 2007-06-20 00:00
Namespace
raritan
Source file
PDU-MIB
Digest
sha256:66971f1f2725621ab09f086906c81a3163e17061f7b6c25e040016469bfbe1e2

Description

This mib describes the SNMP functions of the Dominion PX Power Distribution Unit by Raritan Computer.

Contact

Author: Raritan Americas, Inc. postal: Raritan Americas, Inc. 400 Cottontail Lane Somerset, NJ 08873 email: tech@raritan.com phone: +1 732 764 8886

Imports

FromSymbols
INET-ADDRESS-MIBInetAddress, InetAddressType
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, enterprises, iso
SNMPv2-TCDateAndTime, DisplayString, MacAddress, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

INET-ADDRESS-MIB
PDU-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
DegreesCelsius
TEXTUAL-CONVENTION
Data type for reporting thresholds associated with temperature sensors. If the underlying hardware sensor indicates 1 degree Celsius, then the SNMP agent will report a value of 1 degree Celsius. No scaling is performed for this type.
current
EnabledDisabledEnumeration
TEXTUAL-CONVENTION
The status of a PowerCIM
current
EventDirectionEnumeration
TEXTUAL-CONVENTION
The event direction
current
EventTypeEnumeration
TEXTUAL-CONVENTION
The event type
current
Hertz
TEXTUAL-CONVENTION
Data type for reporting sensor readings and thresholds associated with frequency sensors. If the underlying hardware sensor indicates 1 Hertz, then the SNMP agent will report a value of 1 Hertz. No scaling is performed for this type.
current
MilliAmps
TEXTUAL-CONVENTION
Data type for reporting sensor readings and thresholds associated with current sensors. If the underlying hardware sensor indicates 1 amp, then the SNMP agent will report a value of 1000 milliamps. The value is scaled in this manner as a way to deal with floating point types that SNMP does not currently support.
current
MilliVolts
TEXTUAL-CONVENTION
Data type for reporting sensor readings and thresholds associated with voltage sensors. If the underlying hardware sensor indicates 1 volts, then the SNMP agent will report a value of 1000 millivolts. The value is scaled in this manner as a way to deal with floating point types that SNMP does not currently support.
current
Percentage
TEXTUAL-CONVENTION
Data type for reporting values in percentage.
current
PowerCIMStatusEnumeration
TEXTUAL-CONVENTION
The status of a PowerCIM
current
PowerFactorPercentage
TEXTUAL-CONVENTION
Data type for reporting sensor readings and thresholds associated with power factor sensors. The power factor of an AC power system is defined as the ratio of the real or active power to the apparent power and is a number between 0 and 1. A PowerFactorPercentage value is calculated by taking this ratio and multiplying by 100. The power factor is used to indicate how efficiently a particular load is utilizing energy.
current
RelativeHumidity
TEXTUAL-CONVENTION
Data type for reporting sensor readings and thresholds associated with humidity sensors. Relative humidity is expressed as percentage and is defined as the ratio of the partial pressure of water vapor in a gaseous mixture of air and water vapor to the saturated vapor pressure of water at a given temperature.
current
SensorClassEnumeration
TEXTUAL-CONVENTION
The class of sensor in the event
current
SensorStateEnumeration
TEXTUAL-CONVENTION
The states a sensor can be in.This enumeration is deprecated starting with PX 1.3.5
deprecated
SensorTypeEnumeration
TEXTUAL-CONVENTION
The types a sensor can be. This enumeration is deprecated starting with PX 1.3.5
deprecated
SensorUnitsEnumeration
TEXTUAL-CONVENTION
The types a sensor can be.
current
StateOfSensorEnumeration
TEXTUAL-CONVENTION
The states a sensor can be in.
current
TenthDegreesCelsius
TEXTUAL-CONVENTION
Data type for reporting sensor readings associated with temperature sensors. If the underlying hardware sensor indicates 1 degree Celsius, then the SNMP agent will report a value of 10 tenth degrees Celsius. The value is scaled in this manner as a way to deal with floating point types that SNMP does not currently support.
current
TypeOfSensorEnumeration
TEXTUAL-CONVENTION
The types a sensor can be.
current
VoltAmps
TEXTUAL-CONVENTION
Data type for reporting sensor readings and thresholds associated with apparent power sensors. If the underlying hardware sensor indicates 1 volt-amp, then the SNMP agent will report a value of 1 volt-amp. No scaling is performed for this type.
current
WattHours
TEXTUAL-CONVENTION
Data type for reporting the active energy
current
Watts
TEXTUAL-CONVENTION
Data type for reporting sensor readings and thresholds associated with active power sensors. If the underlying hardware sensor indicates 1 watt, then the SNMP agent will report a value of 1 watt. No scaling is performed for this type.
current

Objects

NameOIDSyntaxAccessStatus
pdu
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4
traps
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.0
board
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.1
info
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.1.1
firmwareVersion
OBJECT-TYPE
The current firmware version in the following format: major.minor.dot.buildnumber. Example: 1.3.5.7416
1.3.6.1.4.1.13742.4.1.1.1DisplayStringread-onlycurrent
serialNumber
OBJECT-TYPE
The serial number.
1.3.6.1.4.1.13742.4.1.1.2DisplayStringread-onlycurrent
ipAddress
OBJECT-TYPE
The current IP address. A value of 0.0.0.0 indicates an error or an unset option.
1.3.6.1.4.1.13742.4.1.1.3IpAddressread-onlycurrent
netmask
OBJECT-TYPE
The current Netmask. A value of 0.0.0.0 indicates an error or an unset option.
1.3.6.1.4.1.13742.4.1.1.4IpAddressread-onlycurrent
gateway
OBJECT-TYPE
The current Gateway. A value of 0.0.0.0 indicates an error or an unset option.
1.3.6.1.4.1.13742.4.1.1.5IpAddressread-onlycurrent
mac
OBJECT-TYPE
The current MAC address.
1.3.6.1.4.1.13742.4.1.1.6MacAddressread-onlycurrent
hardwareRev
OBJECT-TYPE
The hardware revision number.
1.3.6.1.4.1.13742.4.1.1.7Integer32 (0..255)read-onlycurrent
userName
OBJECT-TYPE
The login of a user.
1.3.6.1.4.1.13742.4.1.1.10DisplayStringaccessible-for-notifycurrent
objectName
OBJECT-TYPE
The model type of the device
1.3.6.1.4.1.13742.4.1.1.12DisplayStringaccessible-for-notifycurrent
objectInstance
OBJECT-TYPE
The device name.
1.3.6.1.4.1.13742.4.1.1.13DisplayStringaccessible-for-notifycurrent
targetUser
OBJECT-TYPE
The user record being operated on
1.3.6.1.4.1.13742.4.1.1.14DisplayStringaccessible-for-notifycurrent
groupName
OBJECT-TYPE
The group record being operated on
1.3.6.1.4.1.13742.4.1.1.15DisplayStringaccessible-for-notifycurrent
imageVersion
OBJECT-TYPE
The version of the Upgrade image
1.3.6.1.4.1.13742.4.1.1.18DisplayStringaccessible-for-notifycurrent
sensorDescr
OBJECT-TYPE
Sensor description indicating which sensor experienced a threshold event. When applicable, the description will indicate the sensor number.
1.3.6.1.4.1.13742.4.1.1.19DisplayStringaccessible-for-notifycurrent
thresholdDescr
OBJECT-TYPE
Threshold description indicating which configured threshold has been triggered (or cleared).
1.3.6.1.4.1.13742.4.1.1.20DisplayStringaccessible-for-notifycurrent
thresholdSeverity
OBJECT-TYPE
String (Warning, Critical, etc...) indicating the severity of the threshold which has been triggered (or cleared).
1.3.6.1.4.1.13742.4.1.1.21DisplayStringaccessible-for-notifycurrent
thresholdEventType
OBJECT-TYPE
String (triggered, cleared) indicating if the threshold event indicates that a configured threshold has been triggered or cleared.
1.3.6.1.4.1.13742.4.1.1.22DisplayStringaccessible-for-notifycurrent
status
OBJECT-TYPE
The success status of an operation
1.3.6.1.4.1.13742.4.1.1.23DisplayStringaccessible-for-notifycurrent
slaveIpAddress
OBJECT-TYPE
In an outlet grouping configuration, this is the IP address of slave PDU. A value of 0.0.0.0 indicates an error or an unset option.
1.3.6.1.4.1.13742.4.1.1.24IpAddressread-onlycurrent
inputCurrentRating
OBJECT-TYPE
The input current Rating
1.3.6.1.4.1.13742.4.1.1.25MilliAmpsread-onlycurrent
ratedVoltage
OBJECT-TYPE
PDU Rated Voltage
1.3.6.1.4.1.13742.4.1.1.26DisplayStringread-onlycurrent
ratedPower
OBJECT-TYPE
PDU Rated Power
1.3.6.1.4.1.13742.4.1.1.27DisplayStringread-onlycurrent
outletSwitching
OBJECT-TYPE
Outlet switching: enabled/disabled; for non-switched PDUs, this value can be read, but cannot be written
1.3.6.1.4.1.13742.4.1.1.28DisplayStringread-writecurrent
dataLogging
OBJECT-TYPE
Data Retrieval: enabled/disabled
1.3.6.1.4.1.13742.4.1.1.29DisplayStringread-writecurrent
dataLoggingInterval
OBJECT-TYPE
Data Logging periodicity in seconds. This is the periodicity of the data in the buffer. This value must be a multiple of 3 between 3 and 600. For example, 60 is valid, but 64 is not valid This is being deprecated in favor of measurementsPerLogEntry. The mapping is as follows. dataLoggingInterval measurementsPerLogEntry 3n n Example: dataLoggingInterval is 60, so every 60 seconds (or 20th sample) data will be placed in the data log measurementsPerLogEntry is 20, so the data log sill store the minimum, average and maximum of every 20 samples
1.3.6.1.4.1.13742.4.1.1.30Integer32read-writedeprecated
dataCollectionInterval
OBJECT-TYPE
Data Collection periodicity. This is the periodicity of the data collected by the PX. This value is fixed at 3 seconds.
1.3.6.1.4.1.13742.4.1.1.31Integer32read-onlycurrent
outletEnergySupport
OBJECT-TYPE
Outlet Energy Support: Yes/No If the value is No, then outletWattHours and dataLogOutletWattHours will be zero
1.3.6.1.4.1.13742.4.1.1.32DisplayStringread-onlycurrent
currentUnbalanceSupport
OBJECT-TYPE
current Unbalance calculations Supported: Yes/No If the value is No, then currentUnbalance will be zero Default is No
1.3.6.1.4.1.13742.4.1.1.33DisplayStringread-writecurrent
externalSensorsZCoordinateUnits
OBJECT-TYPE
External Sensor Z Coordinate units: Freeform or Rack Units (U) Default is U
1.3.6.1.4.1.13742.4.1.1.34DisplayStringread-writecurrent
inlineMeter
OBJECT-TYPE
Is this unit an inline meter? Yes/No If Yes, then the folowing pairings hold: Inlet 1 <-> Outlet 1 Inlet 2 <-> Outlet 2 Inlet 3 <-> Outlet 3 Inlet 4 <-> Outlet 4 Use the inletTable to obtain inlet data Use the inletPoleTable to obtain the line data for an inlet.
1.3.6.1.4.1.13742.4.1.1.35DisplayStringread-onlycurrent
oldSensorState
OBJECT-TYPE
The old sensor state used in Sensor State Transition traps.
1.3.6.1.4.1.13742.4.1.1.36StateOfSensorEnumerationaccessible-for-notifycurrent
externalSensorNumber
OBJECT-TYPE
A unique value for each sensor. Its value ranges between 1 and the value of externalSensorCount.
1.3.6.1.4.1.13742.4.1.1.37Integer32 (1..256)accessible-for-notifycurrent
sensorIdentificationString
OBJECT-TYPE
String that uniquely identifies the external sensor. Format is: SensorType,ChannelNumber,SensorSubtype,SerialNumber Example external temperature sensor: Temperature,,,AEI8160083 Example external smoke detection sensor: onOff,2,contact,AEJ8160085 Example outlet Current: rmsCurrent,,,
1.3.6.1.4.1.13742.4.1.1.38DisplayStringaccessible-for-notifycurrent
lastUpgradeStatus
OBJECT-TYPE
A bit string which indicates which the status of the last upgrade. A value of 1 for a bit position indicates that the corresponding upgrade failed. If all bits are zero, then the upgrade succeeded; otherwise check lastUpgradeErrorDescription for further information.
1.3.6.1.4.1.13742.4.1.1.39Bits {mainController(0), psoc1(1), psoc2(2), psoc3(3), psoc4(4), psoc5(5), psoc6(6)}read-onlycurrent
lastUpgradeTimestamp
OBJECT-TYPE
The time when the last upgrade completed
1.3.6.1.4.1.13742.4.1.1.40DateAndTimeread-onlycurrent
lastUpgradeErrorDescription
OBJECT-TYPE
String that describes the upgrade errror. This is an empty string if the upgrade succeeded. Format is Failed PSOCs: 1[O:1,2,3-7];3[O:6-9,10-12] This indicates that upgrade of psocs 1 and 3 failed and psoc1 affects outlets 1,2, 3-7 and psoc2 affects outlets 6-9,10-12
1.3.6.1.4.1.13742.4.1.1.41DisplayStringread-onlycurrent
powerCIMStatus
OBJECT-TYPE
The status of the Power CIM: on or off
1.3.6.1.4.1.13742.4.1.1.42PowerCIMStatusEnumerationread-writecurrent
measurementsPerLogEntry
OBJECT-TYPE
The number of measurements used for each entry in the log. 1<= Value <= 200 Default is 20 This is related to dataLoggingInterval as shown below dataLoggingInterval measurementsPerLogEntry 3n n Example: dataLoggingInterval is 60, so every 60 seconds (or 20th sample) data will be placed in the data log measurementsPerLogEntry is 20, so the data log sill store the minimum, average and maximum of every 20 samples
1.3.6.1.4.1.13742.4.1.1.43Integer32read-writecurrent
psocNumber
OBJECT-TYPE
The psoc (Outlet Controller) number
1.3.6.1.4.1.13742.4.1.1.44Integer32accessible-for-notifycurrent
altitude
OBJECT-TYPE
The altitude (height above sea level) of the PDU in meters. 0 <= Value <= 3000; default value is 0 meters
1.3.6.1.4.1.13742.4.1.1.45Integer32 (0..3000)read-writecurrent
configureAlerts
OBJECT-TYPE
This is an operation. It has write-only semantics. GET operation will return the empty string. For SET operations, it configures alerts The format is a comma separated list of the following parameters. sensorClass, eventType, eventDirection, policyName For sensorclass: use the SensorClass eumeration For eventType: use the EventType enumeration For eventDirection: use the EventDirection enumeration For Policy Name: use the name of the policy; the Policy Name is case sensitive Note: setting this variable will overwrite the existing policy Example: if the External Temperature upper non-critical threshold is either asserted and deasserted, then execute the policy named multiple destinations the string would be 0,1,2,multiple destinations
1.3.6.1.4.1.13742.4.1.1.46DisplayStringread-writecurrent
fipsMode
OBJECT-TYPE
The fips mode: either enabled or disabled. The mode can be set (changed) only if both of the following conditions hold a) the user is admin b) snmpv3 is being used. Changing this mode will result in a reboot of the PX When the PX is in FIPS mode, the follwing conditions hold. a) FIPS approved algorithms must be used b) snmp v1 & v2c are not supported b) snmp v3 must be used with AES and SHA c) https must be used; http is not supported d) Radius authentication is not supported e) Ldaps must be used; ldap is not supported f) ipmi v2.0 must be used
1.3.6.1.4.1.13742.4.1.1.47EnabledDisabledEnumerationread-writecurrent
synchronizeWithNTPServer
OBJECT-TYPE
Will time be obtained using NTP? Deafault is disabled, i.e. time will not be obtained from NTP servers.
1.3.6.1.4.1.13742.4.1.1.48EnabledDisabledEnumerationread-writecurrent
useDHCPProvidedNTPServer
OBJECT-TYPE
Will the NTP server addresses be provided by DHCP/BOOTP? This is used only if synchronizeWithNTPServer is enabled Default is enabled, i.e. DHCP provided NTP servers will be used
1.3.6.1.4.1.13742.4.1.1.49EnabledDisabledEnumerationread-writecurrent
primaryNTPServerAddressType
OBJECT-TYPE
Represents the type of the corresponding instance of primaryNTPServerAddress object.
1.3.6.1.4.1.13742.4.1.1.50InetAddressTyperead-writecurrent
primaryNTPServerAddress
OBJECT-TYPE
The address of the primary ntp server.
1.3.6.1.4.1.13742.4.1.1.51InetAddressread-writecurrent
secondaryNTPServerAddressType
OBJECT-TYPE
Represents the type of the corresponding instance of secondaryNTPServerAddress object. Default is ipv4
1.3.6.1.4.1.13742.4.1.1.52InetAddressTyperead-writecurrent
secondaryNTPServerAddress
OBJECT-TYPE
The address of the secondary ntp server.
1.3.6.1.4.1.13742.4.1.1.53InetAddressread-writecurrent
daylightSavingsTime
OBJECT-TYPE
Is daylight savings time enabled? Default is disabled
1.3.6.1.4.1.13742.4.1.1.55EnabledDisabledEnumerationread-writecurrent
thresholdValue
OBJECT-TYPE
The value of the threshold that has been triggered (or cleared). It is used in the thresholdAlarm trap for external numeric sensors only.
1.3.6.1.4.1.13742.4.1.1.56DisplayStringaccessible-for-notifycurrent
sensorValue
OBJECT-TYPE
The sensor reading that triggered (or cleared) the threshold. It is used in the thresholdAlarm trap for external numeric sensors only.
1.3.6.1.4.1.13742.4.1.1.57DisplayStringaccessible-for-notifycurrent
ipmiOverLAN
OBJECT-TYPE
IPMI over LAN Mode: either enabled or disabled. It is strongly recommended that SNMPv3 be used to change the mode; SNMPv2c may also be used, but is not recommended. If SNMPv3 is used, then the change can be made only by users belonging to the Admin group. Changing the mode will result in a reboot of the PX.
1.3.6.1.4.1.13742.4.1.1.58EnabledDisabledEnumerationread-writecurrent
outlets
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.1.2
outletCount
OBJECT-TYPE
The number of outlets (regardless of their current state) present on this pdu.
1.3.6.1.4.1.13742.4.1.2.1Integer32read-onlycurrent
outletTable
OBJECT-TYPE
A list of outlet entries. The number of entries is given by the value of outletCount.
1.3.6.1.4.1.13742.4.1.2.2not-accessiblecurrent
outletEntry
OBJECT-TYPE
An outlet entry containing objects at the for a particular outlet.
1.3.6.1.4.1.13742.4.1.2.2.1not-accessiblecurrent
outletIndex
OBJECT-TYPE
A unique value for each outlet. Its value ranges between 1 and the value of outletCount.
1.3.6.1.4.1.13742.4.1.2.2.1.1Integer32 (1..256)not-accessiblecurrent
outletLabel
OBJECT-TYPE
A textual string containing information about the outlet.
1.3.6.1.4.1.13742.4.1.2.2.1.2DisplayStringread-writecurrent
outletOperationalState
OBJECT-TYPE
A value for each outlet which describes the operational state of the outlet. It is also used to set the operational state of the outlet
1.3.6.1.4.1.13742.4.1.2.2.1.3INTEGER {error(-1), off(0), on(1), cycling(2)}read-writecurrent
outletCurrent
OBJECT-TYPE
A unique value for the current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp)
1.3.6.1.4.1.13742.4.1.2.2.1.4MilliAmpsread-onlycurrent
outletMaxCurrent
OBJECT-TYPE
A unique value for the max. current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp)
1.3.6.1.4.1.13742.4.1.2.2.1.5MilliAmpsread-onlycurrent
outletVoltage
OBJECT-TYPE
A unique value for the voltage sensor attached to the outlet.This value is reported in millivolts (1/1000th of a volt)
1.3.6.1.4.1.13742.4.1.2.2.1.6MilliVoltsread-onlycurrent
outletActivePower
OBJECT-TYPE
A unique value for the active power sensor attached to the outlet. This value is reported in Watts.
1.3.6.1.4.1.13742.4.1.2.2.1.7Wattsread-onlycurrent
outletApparentPower
OBJECT-TYPE
A unique value for the apparent power sensor attached to the outlet. This value is reported in Volt-Amps
1.3.6.1.4.1.13742.4.1.2.2.1.8VoltAmpsread-onlycurrent
outletPowerFactor
OBJECT-TYPE
A unique value for the power factor of the outlet. The reading represents a percentage in the range of 0% to 100%.
1.3.6.1.4.1.13742.4.1.2.2.1.9PowerFactorPercentageread-onlycurrent
outletCurrentUpperWarning
OBJECT-TYPE
The value of the upper warning (non-critical) current threshold for the outlet. This value is reported in milliamps (1/1000th of an amp)
1.3.6.1.4.1.13742.4.1.2.2.1.20MilliAmpsread-writecurrent
outletCurrentUpperCritical
OBJECT-TYPE
The value of the upper critical current threshold for the outlet. This value is reported in milliamps (1/1000th of an amp)
1.3.6.1.4.1.13742.4.1.2.2.1.21MilliAmpsread-writecurrent
outletCurrentLowerWarning
OBJECT-TYPE
The value of the lower warning (non-critical) current threshold for the outlet. This value is reported in milliamps (1/1000th of an amp)
1.3.6.1.4.1.13742.4.1.2.2.1.22MilliAmpsread-writecurrent
outletCurrentLowerCritical
OBJECT-TYPE
The value of the lower critical current threshold for the outlet. This value is reported in milliamps (1/1000th of an amp)
1.3.6.1.4.1.13742.4.1.2.2.1.23MilliAmpsread-writecurrent
outletCurrentHysteresis
OBJECT-TYPE
The hysteresis used for deassertions. This value is reported in milliamps (1/1000th of an amp)
1.3.6.1.4.1.13742.4.1.2.2.1.24Unsigned32read-writecurrent
outletCurrentRating
OBJECT-TYPE
The current rating of the outlet. This value is reported in milliamps (1/1000th of an amp)
1.3.6.1.4.1.13742.4.1.2.2.1.30MilliAmpsread-onlycurrent
outletWattHours
OBJECT-TYPE
The value of the cumulative active energy for this outlet. This value is reported in WattHours
1.3.6.1.4.1.13742.4.1.2.2.1.31WattHoursread-onlycurrent
unit
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.1.3
unitReadings
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.1.3.1
unitCurrent
OBJECT-TYPE
The value for the unit's current sensor in millamps.This object is deprecated in favour of lineCurrent corresponding to lineCurrentLabel = L1
1.3.6.1.4.1.13742.4.1.3.1.1MilliAmpsread-onlydeprecated
unitVoltage
OBJECT-TYPE
The value for the unit's voltage sensor in millivolts.This object is deprecated in favour of lineVoltage corresponding to lineVoltageLabel = L1
1.3.6.1.4.1.13742.4.1.3.1.2MilliVoltsread-onlydeprecated
unitActivePower
OBJECT-TYPE
The value for the unit's active power in watts.This object is deprecated in favour of inletTable.inletActivePower
1.3.6.1.4.1.13742.4.1.3.1.3Wattsread-onlydeprecated
unitApparentPower
OBJECT-TYPE
The value for the unit's apparent power in volt-amps. This object is deprecated in favour of inletTable.inletApparentPower
1.3.6.1.4.1.13742.4.1.3.1.4VoltAmpsread-onlydeprecated
unitCpuTemp
OBJECT-TYPE
The value for the unit's CPU temperature sensor in tenth degrees celsius.
1.3.6.1.4.1.13742.4.1.3.1.5TenthDegreesCelsiusread-onlycurrent
unitVoltageLowerWarning
OBJECT-TYPE
The value of the lower warning (non-critical) unit level voltage threshold.This object is deprecated in favour of unitOrLineVoltageLowerWarning
1.3.6.1.4.1.13742.4.1.3.1.60MilliVoltsread-writedeprecated
unitVoltageLowerCritical
OBJECT-TYPE
The value of the lower critical unit level voltage threshold.This object is deprecated in favour of unitOrLineVoltageLowerCritical
1.3.6.1.4.1.13742.4.1.3.1.61MilliVoltsread-writedeprecated
unitVoltageUpperWarning
OBJECT-TYPE
The value of the upper warning (non-critical) unit level voltage threshold.This object is deprecated in favour of unitOrLineVoltageUpperWarning
1.3.6.1.4.1.13742.4.1.3.1.62MilliVoltsread-writedeprecated
unitVoltageUpperCritical
OBJECT-TYPE
The value of the upper critical unit level voltage threshold.This object is deprecated in favour of unitOrLineVoltageUpperCritical
1.3.6.1.4.1.13742.4.1.3.1.63MilliVoltsread-writedeprecated
unitCurrentUpperWarning
OBJECT-TYPE
The value of the upper warning (non-critical) unit level current threshold.This object is deprecated in favour of unitOrLineCurrentUpperWarning
1.3.6.1.4.1.13742.4.1.3.1.70MilliAmpsread-writedeprecated
unitCurrentUpperCritical
OBJECT-TYPE
The value of the upper critical unit level current threshold. NOTE: This particular threshold is NOT settable. This object is deprecated in favour of unitOrLineCurrentUpperCritica
1.3.6.1.4.1.13742.4.1.3.1.71MilliAmpsread-onlydeprecated
unitTempLowerWarning
OBJECT-TYPE
The value of the lower warning (non-critical) unit level temperature threshold.
1.3.6.1.4.1.13742.4.1.3.1.80DegreesCelsiusread-writecurrent
unitTempLowerCritical
OBJECT-TYPE
The value of the lower critical unit level temperature threshold.
1.3.6.1.4.1.13742.4.1.3.1.81DegreesCelsiusread-writecurrent
unitTempUpperWarning
OBJECT-TYPE
The value of the upper warning (non-critical) unit level temperature threshold.
1.3.6.1.4.1.13742.4.1.3.1.82DegreesCelsiusread-writecurrent
unitTempUpperCritical
OBJECT-TYPE
The value of the upper critical unit level temperature threshold.
1.3.6.1.4.1.13742.4.1.3.1.83DegreesCelsiusread-writecurrent
currentUnbalance
OBJECT-TYPE
A string displaying the current unbalance in percent. It will have the value NA if the PX is not a 3-phase unit (inletPoleCount = 1),or the feature is disabled (currentUnbalanceSupport = 'No'), or the average of the line currents is zero (inletPoleCurrent = 0 for 1 <= inlePoleIndex <= 3)
1.3.6.1.4.1.13742.4.1.3.1.84DisplayStringread-onlycurrent
currentUnbalanceUpperWarning
OBJECT-TYPE
The value of the upper warning (non-critical) current unbalance threshold.
1.3.6.1.4.1.13742.4.1.3.1.85Percentageread-writecurrent
currentUnbalanceUpperCritical
OBJECT-TYPE
The value of the upper critical current Unbalance threshold.
1.3.6.1.4.1.13742.4.1.3.1.86Percentageread-writecurrent
unitOrLineVoltageLowerWarning
OBJECT-TYPE
The value of the lower warning (non-critical) unit level voltage threshold.
1.3.6.1.4.1.13742.4.1.3.1.90MilliVoltsread-writecurrent
unitOrLineVoltageLowerCritical
OBJECT-TYPE
The value of the lower critical unit level voltage threshold.
1.3.6.1.4.1.13742.4.1.3.1.91MilliVoltsread-writecurrent
unitOrLineVoltageUpperWarning
OBJECT-TYPE
The value of the upper warning (non-critical) unit level voltage
1.3.6.1.4.1.13742.4.1.3.1.92MilliVoltsread-writecurrent
unitOrLineVoltageUpperCritical
OBJECT-TYPE
The value of the upper critical unit level voltage threshold.
1.3.6.1.4.1.13742.4.1.3.1.93MilliVoltsread-writecurrent
unitOrLineCurrentUpperWarning
OBJECT-TYPE
The value of the upper warning (non-critical) unit level current threshold
1.3.6.1.4.1.13742.4.1.3.1.94MilliAmpsread-writecurrent
unitOrLineCurrentUpperCritical
OBJECT-TYPE
The value of the upper critical unit level current threshold.
1.3.6.1.4.1.13742.4.1.3.1.95MilliAmpsread-writecurrent
neutralCurrentUpperWarning
OBJECT-TYPE
This object has an invalid value if inletPoleCount is not equal to 4. If inletPoleCount = 4, then it is the value of the upper warning (non-critical) threshold for the neutral current
1.3.6.1.4.1.13742.4.1.3.1.96MilliAmpsread-writecurrent
neutralCurrentUpperCritical
OBJECT-TYPE
This object has an invalid value if inletPoleCount is not equal to 4. If inletPoleCount = 4, then it is the value of the upper critical threshold for the neutral current.
1.3.6.1.4.1.13742.4.1.3.1.97MilliAmpsread-writecurrent
unitOrLineCurrentHysteresis
OBJECT-TYPE
The hysteresis used for deassertions. This value is reported in milliamps (1/1000th of an amp)
1.3.6.1.4.1.13742.4.1.3.1.98Unsigned32read-writecurrent
unitOrLineVoltageHysteresis
OBJECT-TYPE
The hysteresis used for deassertions. This value is reported in millivolts (1/1000th of a volt)
1.3.6.1.4.1.13742.4.1.3.1.99Unsigned32read-writecurrent
unitTempHysteresis
OBJECT-TYPE
The hysteresis used for deassertions
1.3.6.1.4.1.13742.4.1.3.1.100Unsigned32read-writecurrent
currentUnbalanceHysteresis
OBJECT-TYPE
The hysteresis used for deassertions
1.3.6.1.4.1.13742.4.1.3.1.101Unsigned32read-writecurrent
lineCurrents
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.1.4
lineCurrentCount
OBJECT-TYPE
The number of line currents (1 for single phase, 3 for 3 phase Delta-wired, 4 for 3 phase WYE wired).This object is deprecated in favour of inletPoleTable
1.3.6.1.4.1.13742.4.1.4.1Integer32read-onlydeprecated
lineCurrentTable
OBJECT-TYPE
A list of line input entries. The number of entries is given by the value of lineInputCount. This object is deprecated in favour of inletPoleTable
1.3.6.1.4.1.13742.4.1.4.2not-accessibledeprecated
lineCurrentEntry
OBJECT-TYPE
An entry containing values and threshold settings for a particular line input.This object is deprecated in favour of inletPoleTable
1.3.6.1.4.1.13742.4.1.4.2.1not-accessibledeprecated
lineCurrentIndex
OBJECT-TYPE
A unique value for each line input. Its value ranges between 1 and lineInputCount. This object is deprecated in favour of inletPoleTable
1.3.6.1.4.1.13742.4.1.4.2.1.1Integer32 (1..256)not-accessibledeprecated
lineCurrentLabel
OBJECT-TYPE
A string identifying the Line For Single Phase: L1 For 3phase Delta wired outlets: L1, L2, L3 For 3phase WYE Wired Outlets: L1, L2, L3, N This object is deprecated in favour of inletPoleTable
1.3.6.1.4.1.13742.4.1.4.2.1.2DisplayStringread-onlydeprecated
lineCurrent
OBJECT-TYPE
The value of the current reported in MilliAmps. This object is deprecated in favour of inletPoleTable
1.3.6.1.4.1.13742.4.1.4.2.1.3MilliAmpsread-onlydeprecated
circuitBreaker
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.1.5
circuitBreakerCount
OBJECT-TYPE
The number of circuit breakers.
1.3.6.1.4.1.13742.4.1.5.1Integer32read-onlycurrent
circuitBreakerTable
OBJECT-TYPE
A list of line input entries. The number of entries is given by the value of lineInputCount.
1.3.6.1.4.1.13742.4.1.5.2not-accessiblecurrent
circuitBreakerEntry
OBJECT-TYPE
An entry containing values and threshold settings for a particular line input.
1.3.6.1.4.1.13742.4.1.5.2.1not-accessiblecurrent
circuitBreakerIndex
OBJECT-TYPE
A unique value for each circuit breaker. Its value ranges between 1 and circuitBreakerCount.
1.3.6.1.4.1.13742.4.1.5.2.1.1Integer32 (1..256)not-accessiblecurrent
circuitBreakerLabel
OBJECT-TYPE
A string identifying the circuit breaker
1.3.6.1.4.1.13742.4.1.5.2.1.2DisplayStringread-onlycurrent
circuitBreakerState
OBJECT-TYPE
The value for the circuit breaker state .
1.3.6.1.4.1.13742.4.1.5.2.1.3INTEGER {ok(0), tripped(1)}read-onlycurrent
circuitBreakerCurrentRating
OBJECT-TYPE
The value of the circuit breaker current rating in MilliAmps.
1.3.6.1.4.1.13742.4.1.5.2.1.4MilliAmpsread-onlycurrent
circuitBreakerCurrent
OBJECT-TYPE
The value of the current reported in MilliAmps.
1.3.6.1.4.1.13742.4.1.5.2.1.5MilliAmpsread-onlycurrent
circuitBreakerCurrentUpperWarning
OBJECT-TYPE
The value of the upper warning (non-critical) threshold.
1.3.6.1.4.1.13742.4.1.5.2.1.7MilliAmpsread-writecurrent
circuitBreakerCurrentUpperCritical
OBJECT-TYPE
The value of the upper critical threshold.
1.3.6.1.4.1.13742.4.1.5.2.1.9MilliAmpsread-writecurrent
circuitBreakerCurrentHysteresis
OBJECT-TYPE
The hysteresis used for deassertions reported in milliamps (1/1000th of an amp)
1.3.6.1.4.1.13742.4.1.5.2.1.10Unsigned32read-writecurrent
lineVoltages
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.1.6
lineVoltageCount
OBJECT-TYPE
The number of line voltages (1 for single phase, 3 for 3 phase. This object is deprecated in favour of inletPoleTable
1.3.6.1.4.1.13742.4.1.6.1Integer32read-onlydeprecated
lineVoltageTable
OBJECT-TYPE
A list of line input entries. The number of entries is given by the value of lineInputCount. This object is deprecated in favour of linletPoleTable
1.3.6.1.4.1.13742.4.1.6.2not-accessibledeprecated
lineVoltageEntry
OBJECT-TYPE
An entry containing values and threshold settings for a particular line input. This object is deprecated in favour of inletPoleTable
1.3.6.1.4.1.13742.4.1.6.2.1not-accessibledeprecated
lineVoltageIndex
OBJECT-TYPE
A unique value for each line input. Its value ranges between 1 and lineInputCount. This object is deprecated in favour of inletPoleTable
1.3.6.1.4.1.13742.4.1.6.2.1.1Integer32 (1..256)not-accessibledeprecated
lineVoltageLabel
OBJECT-TYPE
A string identifying the Line For Single Phase: L1 For 3phase Delta-wired: L1-L2, L2-L3, L3-L1 For 3phase Wye-wired: L1-N, L2-N, L3-N This object is deprecated in favour of inletPoleTable
1.3.6.1.4.1.13742.4.1.6.2.1.2DisplayStringread-onlydeprecated
lineVoltage
OBJECT-TYPE
The value of the voltage reported in MilliVolts. This object is deprecated in favour of inletPoleTable
1.3.6.1.4.1.13742.4.1.6.2.1.3MilliVoltsread-onlydeprecated
dataLog
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.1.7
dataLogCount
OBJECT-TYPE
The number of entries in the dataLog table which is a circular buffer.
1.3.6.1.4.1.13742.4.1.7.1Integer32read-onlycurrent
dataLogLatestIndex
OBJECT-TYPE
The index of the latest (most recent) entry in dataLogTable .
1.3.6.1.4.1.13742.4.1.7.2Integer32 (1..256)read-onlycurrent
dataLogTable
OBJECT-TYPE
A list of data log entries. The number of entries is given by the value of dataLogCount.
1.3.6.1.4.1.13742.4.1.7.3not-accessiblecurrent
dataLogEntry
OBJECT-TYPE
An entry in the dataLog buffer containing the unit data collected at the instant specified by dataLogTimeStamp
1.3.6.1.4.1.13742.4.1.7.3.1not-accessiblecurrent
dataLogIndex
OBJECT-TYPE
A unique value for each data sample. Its value ranges between 1 and dataLogCount .
1.3.6.1.4.1.13742.4.1.7.3.1.1Integer32 (1..256)not-accessiblecurrent
dataLogTimeStamp
OBJECT-TYPE
The time when the data was collected. It is measured in seconds relative to January 1, 1970 (midnight UTC/GMT), i.e a value of 0 indicates January 1, 1970 (midnight UTC/GMT)
1.3.6.1.4.1.13742.4.1.7.3.1.2Unsigned32read-onlycurrent
dataLogActivePower
OBJECT-TYPE
The value for the pdu's active power sensor in watts. This has been deprecated in favor of dataLogAvgActivePower, dataLogMaxActivePower,dataLogMinActivePower
1.3.6.1.4.1.13742.4.1.7.3.1.3Wattsread-onlydeprecated
dataLogApparentPower
OBJECT-TYPE
The value for the pdu's apparent power sensor in volt-amps. This has been deprecated in favor of dataLogAvgApparentPower, dataLogMaxApparentPower,dataLogMinApparentPower
1.3.6.1.4.1.13742.4.1.7.3.1.4VoltAmpsread-onlydeprecated
dataLogAvgActivePower
OBJECT-TYPE
The average active power for this measurement period
1.3.6.1.4.1.13742.4.1.7.3.1.5Wattsread-onlycurrent
dataLogMaxActivePower
OBJECT-TYPE
The maximum active power for this measurement period
1.3.6.1.4.1.13742.4.1.7.3.1.6Wattsread-onlycurrent
dataLogMinActivePower
OBJECT-TYPE
The minimum active power for this measurement period
1.3.6.1.4.1.13742.4.1.7.3.1.7Wattsread-onlycurrent
dataLogAvgApparentPower
OBJECT-TYPE
The average apparent power for this measurement period
1.3.6.1.4.1.13742.4.1.7.3.1.8VoltAmpsread-onlycurrent
dataLogMaxApparentPower
OBJECT-TYPE
The maximum apparent power for this measurement period
1.3.6.1.4.1.13742.4.1.7.3.1.9VoltAmpsread-onlycurrent
dataLogMinApparentPower
OBJECT-TYPE
The minimum apparent power for this measurement period
1.3.6.1.4.1.13742.4.1.7.3.1.10VoltAmpsread-onlycurrent
dataLogOutlet
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.1.10
dataLogOutletTable
OBJECT-TYPE
A list of outlet entries. The number of entries is given by the value of outletCount.
1.3.6.1.4.1.13742.4.1.10.1not-accessiblecurrent
dataLogOutletEntry
OBJECT-TYPE
An entry in the data log containing outlet level data for a particular outlet.
1.3.6.1.4.1.13742.4.1.10.1.1not-accessiblecurrent
dataLogOutletIndex
OBJECT-TYPE
A unique value for each outlet. Its value ranges between 1 and the value of outletCount.
1.3.6.1.4.1.13742.4.1.10.1.1.1Integer32 (1..256)not-accessiblecurrent
dataLogOutletCurrent
OBJECT-TYPE
A unique value for the current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp) This has been deprecated in favor of dataLogAvgOutletCurrent , dataLogMaxOutletCurrent ,dataLogMinOutletCurrent
1.3.6.1.4.1.13742.4.1.10.1.1.2MilliAmpsread-onlydeprecated
dataLogOutletVoltage
OBJECT-TYPE
A unique value for the voltage sensor attached to the outlet.This value is reported in millivolts (1/1000th of a volt) This has been deprecated in favor of dataLogAvgOutletVoltage , dataLogMaxOutletVoltage ,dataLogMinOutletVoltage
1.3.6.1.4.1.13742.4.1.10.1.1.3MilliVoltsread-onlydeprecated
dataLogOutletPowerFactor
OBJECT-TYPE
A unique value for the power factor of the outlet. The reading represents a percentage in the range of 0% to 100%. This has been deprecated in favor of dataLogAvgOutletPowerFactor, dataLogMaxOutletPowerFactor,dataLogMinOutletPowerFactor
1.3.6.1.4.1.13742.4.1.10.1.1.4PowerFactorPercentageread-onlydeprecated
dataLogOutletOnTime
OBJECT-TYPE
The amount of time since this outlet was last switched on. This value is reported in seconds.
1.3.6.1.4.1.13742.4.1.10.1.1.5Unsigned32read-onlycurrent
dataLogOutletWattHours
OBJECT-TYPE
The cumulative Active Energy for this outlet. This value is reported in WattHours This has been deprecated in favor of dataLogAvgOutletWattHours , dataLogMaxOutletWattHours ,dataLogMinOutletWattHours
1.3.6.1.4.1.13742.4.1.10.1.1.6WattHoursread-onlydeprecated
dataLogAvgOutletCurrent
OBJECT-TYPE
The Average value for the measurement period: A unique value for the current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp)
1.3.6.1.4.1.13742.4.1.10.1.1.7MilliAmpsread-onlycurrent
dataLogMaxOutletCurrent
OBJECT-TYPE
The Maximum value for the measurement period: A unique value for the current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp)
1.3.6.1.4.1.13742.4.1.10.1.1.8MilliAmpsread-onlycurrent
dataLogMinOutletCurrent
OBJECT-TYPE
The Minimum value for the measurement period: A unique value for the current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp)
1.3.6.1.4.1.13742.4.1.10.1.1.9MilliAmpsread-onlycurrent
dataLogAvgOutletVoltage
OBJECT-TYPE
The Average value for the measurement period: A unique value for the voltage sensor attached to the outlet.This value is reported in millivolts (1/1000th of a volt)
1.3.6.1.4.1.13742.4.1.10.1.1.10MilliVoltsread-onlycurrent
dataLogMaxOutletVoltage
OBJECT-TYPE
The Maximum value for the measurement period: A unique value for the voltage sensor attached to the outlet.This value is reported in millivolts (1/1000th of a volt)
1.3.6.1.4.1.13742.4.1.10.1.1.11MilliVoltsread-onlycurrent
dataLogMinOutletVoltage
OBJECT-TYPE
The Minimum value for the measurement period: A unique value for the voltage sensor attached to the outlet.This value is reported in millivolts (1/1000th of a volt)
1.3.6.1.4.1.13742.4.1.10.1.1.12MilliVoltsread-onlycurrent
dataLogAvgOutletPowerFactor
OBJECT-TYPE
The Average value for the measurement period: A unique value for the power factor of the outlet. The reading represents a percentage in the range of 0% to 100%
1.3.6.1.4.1.13742.4.1.10.1.1.13PowerFactorPercentageread-onlycurrent
dataLogMaxOutletPowerFactor
OBJECT-TYPE
The Maximum value for the measurement period: A unique value for the power factor of the outlet. The reading represents a percentage in the range of 0% to 100%
1.3.6.1.4.1.13742.4.1.10.1.1.14PowerFactorPercentageread-onlycurrent
dataLogMinOutletPowerFactor
OBJECT-TYPE
The Minimum value for the measurement period: A unique value for the power factor of the outlet. The reading represents a percentage in the range of 0% to 100%
1.3.6.1.4.1.13742.4.1.10.1.1.15PowerFactorPercentageread-onlycurrent
dataLogAvgOutletWattHours
OBJECT-TYPE
The Average value for the measurement period: The cumulative Active Energy for this outlet. This value is reported in WattHours
1.3.6.1.4.1.13742.4.1.10.1.1.16WattHoursread-onlycurrent
dataLogMaxOutletWattHours
OBJECT-TYPE
The Maximum value for the measurement period: The cumulative Active Energy for this outlet. This value is reported in WattHours
1.3.6.1.4.1.13742.4.1.10.1.1.17WattHoursread-onlycurrent
dataLogMinOutletWattHours
OBJECT-TYPE
The Minimum value for the measurement period: The cumulative Active Energy for this outlet. This value is reported in WattHours
1.3.6.1.4.1.13742.4.1.10.1.1.18WattHoursread-onlycurrent
dataLogInlet
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.1.12
dataLogInletTable
OBJECT-TYPE
A list of inlet entries. The number of entries is given by the value of inletCount.
1.3.6.1.4.1.13742.4.1.12.2not-accessiblecurrent
dataLogInletEntry
OBJECT-TYPE
An inlet entry containing objects at the for a particular outlet.
1.3.6.1.4.1.13742.4.1.12.2.1not-accessiblecurrent
dataLogInletIndex
OBJECT-TYPE
A unique value for each inlet. Its value ranges between 1 and the value of inletCount.
1.3.6.1.4.1.13742.4.1.12.2.1.1Integer32 (1..256)not-accessiblecurrent
dataLogInletCurrentUnbalance
OBJECT-TYPE
A string displaying the current unbalance in percent. It will have the value NA if the feature is disabled, the PX is not a 3-phase unit,or the average of the line currents is zero This has been deprecated in favor of dataLogAvgInletCurrentUnbalance, dataLogMaxInletCurrentUnbalance, dataLogMinInletCurrentUnbalance
1.3.6.1.4.1.13742.4.1.12.2.1.10DisplayStringread-onlydeprecated
dataLogInletActivePower
OBJECT-TYPE
The active power for the inlet This value is reported in Watts. This has been deprecated in favor of dataLogAvgInletActivePower, dataLogMaxInletActivePower, dataLogMinInletActivePower
1.3.6.1.4.1.13742.4.1.12.2.1.11Wattsread-onlydeprecated
dataLogInletApparentPower
OBJECT-TYPE
The apparent power for the inlet. This value is reported in Volt-Amps This has been deprecated in favor of dataLogAvgInletApparentPower, dataLogMaxInletApparentPower, dataLogMinInletApparentPower
1.3.6.1.4.1.13742.4.1.12.2.1.12VoltAmpsread-onlydeprecated
dataLogInletActiveEnergy
OBJECT-TYPE
The value of the cumulative active energy for this inlet. This value is reported in WattHours This has been deprecated in favor of dataLogAvgInletActiveEnergy, dataLogMaxInletActiveEnergy, dataLogMinInletActiveEnergy
1.3.6.1.4.1.13742.4.1.12.2.1.13WattHoursread-onlydeprecated
dataLogAvgInletCurrentUnbalance
OBJECT-TYPE
The average value of the current unbalance for this measurement period A string displaying the current unbalance in percent. It will have the value NA if the feature is disabled, the PX is not a 3-phase unit,or the average of the line currents is zero
1.3.6.1.4.1.13742.4.1.12.2.1.14DisplayStringread-onlycurrent
dataLogMaxInletCurrentUnbalance
OBJECT-TYPE
The Maximum value for the measurement period: A string displaying the current unbalance in percent. It will have the value NA if the feature is disabled, the PX is not a 3-phase unit,or the average of the line currents is zero
1.3.6.1.4.1.13742.4.1.12.2.1.15DisplayStringread-onlycurrent
dataLogMinInletCurrentUnbalance
OBJECT-TYPE
The Minimum value for the measurement period: A string displaying the current unbalance in percent. It will have the value NA if the feature is disabled, the PX is not a 3-phase unit,or the average of the line currents is zero
1.3.6.1.4.1.13742.4.1.12.2.1.16DisplayStringread-onlycurrent
dataLogAvgInletActivePower
OBJECT-TYPE
The Average value for the measurement period: The active power for the inlet This value is reported in Watts.
1.3.6.1.4.1.13742.4.1.12.2.1.17Wattsread-onlycurrent
dataLogMaxInletActivePower
OBJECT-TYPE
The Maximum value for the measurement period: The active power for the inlet This value is reported in Watts.
1.3.6.1.4.1.13742.4.1.12.2.1.18Wattsread-onlycurrent
dataLogMinInletActivePower
OBJECT-TYPE
The Minimum value for the measurement period: The active power for the inlet This value is reported in Watts.
1.3.6.1.4.1.13742.4.1.12.2.1.19Wattsread-onlycurrent
dataLogAvgInletApparentPower
OBJECT-TYPE
The Average value for the measurement period: The apparent power for the inlet. This value is reported in Volt-Amps
1.3.6.1.4.1.13742.4.1.12.2.1.20VoltAmpsread-onlycurrent
dataLogMaxInletApparentPower
OBJECT-TYPE
The Maximum value for the measurement period: The apparent power for the inlet. This value is reported in Volt-Amps
1.3.6.1.4.1.13742.4.1.12.2.1.21VoltAmpsread-onlycurrent
dataLogMinInletApparentPower
OBJECT-TYPE
The Minimum value for the measurement period: The apparent power for the inlet. This value is reported in Volt-Amps
1.3.6.1.4.1.13742.4.1.12.2.1.22VoltAmpsread-onlycurrent
dataLogAvgInletActiveEnergy
OBJECT-TYPE
The Average value for the measurement period: The value of the cumulative active energy for this inlet. This value is reported in WattHours
1.3.6.1.4.1.13742.4.1.12.2.1.23WattHoursread-onlycurrent
dataLogMaxInletActiveEnergy
OBJECT-TYPE
The Maximum value for the measurement period: The value of the cumulative active energy for this inlet. This value is reported in WattHours
1.3.6.1.4.1.13742.4.1.12.2.1.24WattHoursread-onlycurrent
dataLogMinInletActiveEnergy
OBJECT-TYPE
The Minimum value for the measurement period: The value of the cumulative active energy for this inlet. This value is reported in WattHours
1.3.6.1.4.1.13742.4.1.12.2.1.25WattHoursread-onlycurrent
dataLogInletPole
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.1.13
dataLogInletPoleTable
OBJECT-TYPE
A list of line input entries. The number of entries is given by the value of dataLoginletTable(dataLogInletIndex).inletPoleCount.
1.3.6.1.4.1.13742.4.1.13.1not-accessiblecurrent
dataLogInletPoleEntry
OBJECT-TYPE
An entry in the data log containing input line values for a particular input line.
1.3.6.1.4.1.13742.4.1.13.1.1not-accessiblecurrent
dataLogInletPoleIndex
OBJECT-TYPE
A unique value for each line input. Its value ranges between 1 and lineCurrentCount.
1.3.6.1.4.1.13742.4.1.13.1.1.1Integer32 (1..256)not-accessiblecurrent
dataLogInletPoleCurrent
OBJECT-TYPE
The value of the current reported in MilliAmps. For Single Phase: Input Line Current For 3phase Delta-wired: Current for L1, L2, L3 For 3phase WYE-wired: Current for L1, L2, L3, N This has been deprecated in favor of dataLogAvgInletPoleCurrent, dataLogMaxInletPoleCurrent, dataLogMinInletPoleCurrent
1.3.6.1.4.1.13742.4.1.13.1.1.2MilliAmpsread-onlydeprecated
dataLogInletPoleVoltage
OBJECT-TYPE
The value of the voltage reported in MilliVolts. For Single Phase: Input Line Voltage For 3phase Delta-wired: Voltages for L1-L2, L2-L3, L3-L1 For 3phase WYE-wired: Voltages for L1-N, L2-N, L3-N This has been deprecated in favor of dataLogAvgInletPoleVoltage, dataLogMaxInletPoleVoltage, dataLogMinInletPoleVoltage
1.3.6.1.4.1.13742.4.1.13.1.1.3MilliVoltsread-onlydeprecated
dataLogAvgInletPoleCurrent
OBJECT-TYPE
The Average value for the measurement period: The value of the current reported in MilliAmps. For Single Phase: Input Line Current For 3phase Delta-wired: Current for L1, L2, L3 For 3phase WYE-wired: Current for L1, L2, L3, N
1.3.6.1.4.1.13742.4.1.13.1.1.4MilliAmpsread-onlycurrent
dataLogMaxInletPoleCurrent
OBJECT-TYPE
The Maximum value for the measurement period: The value of the current reported in MilliAmps. For Single Phase: Input Line Current For 3phase Delta-wired: Current for L1, L2, L3 For 3phase WYE-wired: Current for L1, L2, L3, N
1.3.6.1.4.1.13742.4.1.13.1.1.5MilliAmpsread-onlycurrent
dataLogMinInletPoleCurrent
OBJECT-TYPE
The Minimum value for the measurement period: The value of the current reported in MilliAmps. For Single Phase: Input Line Current For 3phase Delta-wired: Current for L1, L2, L3 For 3phase WYE-wired: Current for L1, L2, L3, N
1.3.6.1.4.1.13742.4.1.13.1.1.6MilliAmpsread-onlycurrent
dataLogAvgInletPoleVoltage
OBJECT-TYPE
The Average value for the measurement period: The value of the voltage reported in MilliVolts. For Single Phase: Input Line Voltage For 3phase Delta-wired: Voltages for L1-L2, L2-L3, L3-L1 For 3phase WYE-wired: Voltages for L1-N, L2-N, L3-N
1.3.6.1.4.1.13742.4.1.13.1.1.7MilliVoltsread-onlycurrent
dataLogMaxInletPoleVoltage
OBJECT-TYPE
The Maximum value for the measurement period: The value of the voltage reported in MilliVolts. For Single Phase: Input Line Voltage For 3phase Delta-wired: Voltages for L1-L2, L2-L3, L3-L1 For 3phase WYE-wired: Voltages for L1-N, L2-N, L3-N
1.3.6.1.4.1.13742.4.1.13.1.1.8MilliVoltsread-onlycurrent
dataLogMinInletPoleVoltage
OBJECT-TYPE
The Minimum value for the measurement period: The value of the voltage reported in MilliVolts. For Single Phase: Input Line Voltage For 3phase Delta-wired: Voltages for L1-L2, L2-L3, L3-L1 For 3phase WYE-wired: Voltages for L1-N, L2-N, L3-N
1.3.6.1.4.1.13742.4.1.13.1.1.9MilliVoltsread-onlycurrent
dataLogAvgInletPoleActivePower
OBJECT-TYPE
This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Average value of the active power for the measurement period. The value is reported in Watts.
1.3.6.1.4.1.13742.4.1.13.1.1.10Wattsread-onlycurrent
dataLogMaxInletPoleActivePower
OBJECT-TYPE
This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Maximum value of the active power for the measurement period. The value is reported in Watts.
1.3.6.1.4.1.13742.4.1.13.1.1.11Wattsread-onlycurrent
dataLogMinInletPoleActivePower
OBJECT-TYPE
This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Minimum value of the active power for the measurement period. The value is reported in Watts.
1.3.6.1.4.1.13742.4.1.13.1.1.12Wattsread-onlycurrent
dataLogAvgInletPoleApparentPower
OBJECT-TYPE
This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Average value of the apparent power for the measurement period. The value is reported in Volt-Amps
1.3.6.1.4.1.13742.4.1.13.1.1.13VoltAmpsread-onlycurrent
dataLogMaxInletPoleApparentPower
OBJECT-TYPE
This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Maximum value of the apparent power for the measurement period. The value is reported in Volt-Amps
1.3.6.1.4.1.13742.4.1.13.1.1.14VoltAmpsread-onlycurrent
dataLogMinInletPoleApparentPower
OBJECT-TYPE
This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Minimum value of the apparent power for the measurement period. The value is reported in Volt-Amps
1.3.6.1.4.1.13742.4.1.13.1.1.15VoltAmpsread-onlycurrent
dataLogAvgInletPoleActiveEnergy
OBJECT-TYPE
This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Average value of the active energy for the measurement period. The value is reported in WattHours
1.3.6.1.4.1.13742.4.1.13.1.1.16WattHoursread-onlycurrent
dataLogMaxInletPoleActiveEnergy
OBJECT-TYPE
This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Maximum value of the active energy for the measurement period. The value is reported in WattHours
1.3.6.1.4.1.13742.4.1.13.1.1.17WattHoursread-onlycurrent
dataLogMinInletPoleActiveEnergy
OBJECT-TYPE
This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the the Minimum value of the active energy for the measurement period. The value is reported in WattHours
1.3.6.1.4.1.13742.4.1.13.1.1.18WattHoursread-onlycurrent
dataLogInputLine
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.1.14
dataLogInputLineTable
OBJECT-TYPE
A list of line input entries. The number of entries is given by the value of lineCurrentCount. This object is deprecated in favour of dataLogInletLineTable
1.3.6.1.4.1.13742.4.1.14.1not-accessibledeprecated
dataLogInputLineEntry
OBJECT-TYPE
An entry in the data log containing input line values for a particular input line. This object is deprecated in favour of dataLogInletLineTable
1.3.6.1.4.1.13742.4.1.14.1.1not-accessibledeprecated
dataLogInputLineIndex
OBJECT-TYPE
A unique value for each line input. Its value ranges between 1 and inletTable(inletIndex).inletPoleCount. This object is deprecated in favour of dataLogInletLineTable
1.3.6.1.4.1.13742.4.1.14.1.1.1Integer32 (1..256)not-accessibledeprecated
dataLogInputLineCurrent
OBJECT-TYPE
The value of the current reported in MilliAmps. For Single Phase: Input Line Current For 3phase Delta-wired: Current for L1, L2, L3 For 3phase WYE-wired: Current for L1, L2, L3, N This object is deprecated in favour of dataLogInletLineTable
1.3.6.1.4.1.13742.4.1.14.1.1.2MilliAmpsread-onlydeprecated
dataLogInputLineVoltage
OBJECT-TYPE
The value of the voltage reported in MilliVolts. For Single Phase: Input Line Voltage For 3phase Delta-wired: Voltages for L1-L2, L2-L3, L3-L1 For 3phase WYE-wired: Voltages for L1-N, L2-N, L3-N This object is deprecated in favour of dataLogInletLineTable
1.3.6.1.4.1.13742.4.1.14.1.1.3MilliVoltsread-onlydeprecated
dataLogCircuitBreaker
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.1.15
dataLogCircuitBreakerTable
OBJECT-TYPE
A list of circuit breaker entries. The number of entries is given by the value of circuitBreakerCount.
1.3.6.1.4.1.13742.4.1.15.1not-accessiblecurrent
dataLogCircuitBreakerEntry
OBJECT-TYPE
An entry in the data log containing circuit breaker values
1.3.6.1.4.1.13742.4.1.15.1.1not-accessiblecurrent
dataLogCircuitBreakerIndex
OBJECT-TYPE
A unique value for each circuit breaker. Its value ranges between 1 and circuitBreakerCount.
1.3.6.1.4.1.13742.4.1.15.1.1.1Integer32 (1..256)not-accessiblecurrent
dataLogCircuitBreakerCurrent
OBJECT-TYPE
The value of the current reported in MilliAmps. This has been deprecated in favor of dataLogAvgCircuitBreakerCurrent, dataLogMaxOutletCircuitBreakerCurrent, dataLogMinCircuitBreakerCurrent
1.3.6.1.4.1.13742.4.1.15.1.1.2MilliAmpsread-onlydeprecated
dataLogAvgCircuitBreakerCurrent
OBJECT-TYPE
The Average value for the measurement period: The value of the current reported in MilliAmps.
1.3.6.1.4.1.13742.4.1.15.1.1.3MilliAmpsread-onlycurrent
dataLogMaxCircuitBreakerCurrent
OBJECT-TYPE
The Maximum value for the measurement period: The value of the current reported in MilliAmps.
1.3.6.1.4.1.13742.4.1.15.1.1.4MilliAmpsread-onlycurrent
dataLogMinCircuitBreakerCurrent
OBJECT-TYPE
The Minimum value for the measurement period: The value of the current reported in MilliAmps.
1.3.6.1.4.1.13742.4.1.15.1.1.5MilliAmpsread-onlycurrent
dataLogExternalSensor
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.1.16
dataLogExternalSensorTable
OBJECT-TYPE
A list of external sensor entries. The number of entries is given by the value of externalSensorCount.
1.3.6.1.4.1.13742.4.1.16.1not-accessiblecurrent
dataLogExternalSensorEntry
OBJECT-TYPE
An entry in the data log containing external sensor values
1.3.6.1.4.1.13742.4.1.16.1.1not-accessiblecurrent
dataLogExternalSensorIndex
OBJECT-TYPE
A unique value for each external sensor. Its value ranges between 1 and externalSensorCount.
1.3.6.1.4.1.13742.4.1.16.1.1.1Integer32 (1..256)not-accessiblecurrent
dataLogExternalSensorChanged
OBJECT-TYPE
Indicates whether there has been a change in the sensor type/subtype/channel number for this sensorID. This can occur if sensorIDs have been reassigned as a result of a GUI operation or a SET operation on reorderexternalSensorTableEntries. Format: SerialNumber=xxxxxxxx; SensorType=dd; SensorSubType=d; ChannelNumber=d SensorSubType and ChannelNumber are present only if NewSensorType=onOff If there was no change from the previous sample, then this string is empty. Examples: Sensor changed to Temperature: SerialNumber=AEI8160083; SensorType=10; Sensor changed to onOff/SmokeDetection: SerialNumber=AEI8160083; SensorType=14; SensorSubType= 18; ChannelNumber=1 Sensor Channel Number changed: SerialNumber=AEI8160083; SensorType=14; SensorSubType= 18; ChannelNumber=2 Sensor SubType changed: SerialNumber=AEI8160083; SensorType=14; SensorSubType= 19; ChannelNumber=2
1.3.6.1.4.1.13742.4.1.16.1.1.2DisplayStringread-onlycurrent
dataLogExternalSensorState
OBJECT-TYPE
The sensor state.
1.3.6.1.4.1.13742.4.1.16.1.1.3StateOfSensorEnumerationread-onlycurrent
dataLogAvgExternalSensorValue
OBJECT-TYPE
The Average of the sensor values Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors. This value is not valid if dataLogExternalSensorState is unavailable(-1).
1.3.6.1.4.1.13742.4.1.16.1.1.4Integer32read-onlycurrent
dataLogMaxExternalSensorValue
OBJECT-TYPE
The Maximum of the sensor values Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors This value is not valid if dataLogExternalSensorState is unavailable(-1).
1.3.6.1.4.1.13742.4.1.16.1.1.5Integer32read-onlycurrent
dataLogMinExternalSensorValue
OBJECT-TYPE
The Minimum of the sensor values. Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors This value is not valid if dataLogExternalSensorState is unavailable(-1).
1.3.6.1.4.1.13742.4.1.16.1.1.6Integer32read-onlycurrent
inlets
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.1.20
inletCount
OBJECT-TYPE
The number of inlets present on this pdu.
1.3.6.1.4.1.13742.4.1.20.1Integer32read-onlycurrent
inletTable
OBJECT-TYPE
A list of inlet entries. The number of entries is given by the value of inletCount.
1.3.6.1.4.1.13742.4.1.20.2not-accessiblecurrent
inletEntry
OBJECT-TYPE
An inlet entry containing objects for each inlet
1.3.6.1.4.1.13742.4.1.20.2.1not-accessiblecurrent
inletIndex
OBJECT-TYPE
A unique value for each inlet. Its value ranges between 1 and the value of inletCount.
1.3.6.1.4.1.13742.4.1.20.2.1.1Integer32 (1..256)not-accessiblecurrent
inletPoleCount
OBJECT-TYPE
The number of poles for an inlet (1 for single phase, 3 for 3 phase Delta-wired, 4 for 3 phase WYE wired).
1.3.6.1.4.1.13742.4.1.20.2.1.3Integer32read-onlycurrent
inletCurrentRating
OBJECT-TYPE
The input current Rating
1.3.6.1.4.1.13742.4.1.20.2.1.4MilliAmpsread-onlycurrent
inletCurrent
OBJECT-TYPE
A unique value for the current sensor attached to the inlet. This value is reported in milliamps (1/1000th of an amp). This OID does not apply to 3 phase systems; a value of 0 will be reported for same.
1.3.6.1.4.1.13742.4.1.20.2.1.7MilliAmpsread-onlycurrent
inletVoltage
OBJECT-TYPE
A unique value for the voltage sensor attached to the intlet.This value is reported in millivolts (1/1000th of a volt). This OID does not apply to 3 phase systems; a value of 0 will be reported for same.
1.3.6.1.4.1.13742.4.1.20.2.1.8MilliVoltsread-onlycurrent
inletActivePower
OBJECT-TYPE
The active power for the inlet This value is reported in Watts.
1.3.6.1.4.1.13742.4.1.20.2.1.9Wattsread-onlycurrent
inletApparentPower
OBJECT-TYPE
The apparent power for the inlet. This value is reported in Volt-Amps
1.3.6.1.4.1.13742.4.1.20.2.1.10VoltAmpsread-onlycurrent
inletPowerFactor
OBJECT-TYPE
A unique value for the power factor of the inlet. The reading represents a percentage in the range of 0% to 100%.
1.3.6.1.4.1.13742.4.1.20.2.1.11PowerFactorPercentageread-onlycurrent
inletActiveEnergy
OBJECT-TYPE
This object has an invalid value if outletEnergySupport = 'No'; In all other cases, it is the value of the cumulative active energy for this inlet. This value is reported in WattHours
1.3.6.1.4.1.13742.4.1.20.2.1.12WattHoursread-onlycurrent
inletCurrentUnbalance
OBJECT-TYPE
A string displaying the current unbalance in percent. It will have the value NA if the feature is disabled, the PX is not a 3-phase unit,or the average of the line currents is zero
1.3.6.1.4.1.13742.4.1.20.2.1.15DisplayStringread-onlycurrent
inletCurrentUpperWarning
OBJECT-TYPE
The value of the upper warning (non-critical) current threshold for the inlet. This value is reported in milliamps (1/1000th of an amp)
1.3.6.1.4.1.13742.4.1.20.2.1.20MilliAmpsread-writecurrent
inletCurrentUpperCritical
OBJECT-TYPE
The value of the upper critical current threshold for the inlet. This value is reported in milliamps (1/1000th of an amp)
1.3.6.1.4.1.13742.4.1.20.2.1.21MilliAmpsread-writecurrent
inletCurrentLowerWarning
OBJECT-TYPE
The value of the lower warning (non-critical) current threshold for the inlet. This value is reported in milliamps (1/1000th of an amp). This OID is valid for inline meter PDU's. only
1.3.6.1.4.1.13742.4.1.20.2.1.22MilliAmpsread-writecurrent
inletCurrentLowerCritical
OBJECT-TYPE
The value of the lower critical current threshold for the inlet. This value is reported in milliamps (1/1000th of an amp). This OID is valid for inline meter PDU's only.
1.3.6.1.4.1.13742.4.1.20.2.1.23MilliAmpsread-writecurrent
inletVoltageUpperWarning
OBJECT-TYPE
The value of the upper warning (non-critical) current threshold for the inlet. This value is reported in millivolts (1/1000th of a volt)
1.3.6.1.4.1.13742.4.1.20.2.1.24MilliVoltsread-writecurrent
inletVoltageUpperCritical
OBJECT-TYPE
The value of the upper critical current threshold for the inlet. This value is reported in millivolts (1/1000th of a volt)
1.3.6.1.4.1.13742.4.1.20.2.1.25MilliVoltsread-writecurrent
inletVoltageLowerWarning
OBJECT-TYPE
The value of the lower warning (non-critical) current threshold for the inlet. This value is reported in millivolts (1/1000th of a volt)
1.3.6.1.4.1.13742.4.1.20.2.1.26MilliVoltsread-writecurrent
inletVoltageLowerCritical
OBJECT-TYPE
The value of the lower critical current threshold for the inlet. This value is reported in millivolts (1/1000th of a volt)
1.3.6.1.4.1.13742.4.1.20.2.1.27MilliVoltsread-writecurrent
inletCurrentUnbalanceUpperCritical
OBJECT-TYPE
The value of the upper critical current Unbalance threshold.
1.3.6.1.4.1.13742.4.1.20.2.1.28Percentageread-writecurrent
inletCurrentUnbalanceUpperWarning
OBJECT-TYPE
The value of the upper warning current Unbalance threshold.
1.3.6.1.4.1.13742.4.1.20.2.1.29Percentageread-writecurrent
inletCurrentHysteresis
OBJECT-TYPE
The hysteresis used for deassertions. This value is reported in milliamps (1/1000th of an amp)
1.3.6.1.4.1.13742.4.1.20.2.1.30Unsigned32read-writecurrent
inletVoltageHysteresis
OBJECT-TYPE
The hysteresis used for deassertions. This value is reported in millivolts (1/1000th of a volt)
1.3.6.1.4.1.13742.4.1.20.2.1.31Unsigned32read-writecurrent
inletCurrentUnbalanceHysteresis
OBJECT-TYPE
The hysteresis used for deassertions. This value is reported in percent
1.3.6.1.4.1.13742.4.1.20.2.1.32Unsigned32read-writecurrent
inletPole
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.1.21
inletPoleTable
OBJECT-TYPE
A list of line input entries. The number of entries is given by the value of inletTable(inletIndex).inletPoleCount.
1.3.6.1.4.1.13742.4.1.21.2not-accessiblecurrent
inletPoleEntry
OBJECT-TYPE
An entry in the data log containing input line values for a particular input line.
1.3.6.1.4.1.13742.4.1.21.2.1not-accessiblecurrent
inletPoleIndex
OBJECT-TYPE
A unique value for each line input. Its value ranges between 1 and of inletTable(inletIndex).inletPoleCount.
1.3.6.1.4.1.13742.4.1.21.2.1.1Integer32 (1..256)not-accessiblecurrent
inletPoleLabel
OBJECT-TYPE
A string identifying the Line For Single Phase: L1 For 3phase Delta wired outlets: L1, L2, L3 For 3phase WYE Wired Outlets: L1, L2, L3
1.3.6.1.4.1.13742.4.1.21.2.1.2DisplayStringread-onlycurrent
inletPoleCurrent
OBJECT-TYPE
The value of the line current reported in MilliAmps. inletPoleIndex = 1; For Single Phase, Input Line Current; For 3-phase, L1 Current inletPoleIndex = 2; For 3-phase, L2 Current inletPoleIndex = 3; For 3-phase, L3 Current
1.3.6.1.4.1.13742.4.1.21.2.1.3MilliAmpsread-onlycurrent
inletPoleVoltage
OBJECT-TYPE
The value of the line-line voltage reported in MilliVolts. inletPoleIndex = 1; Single Phase Input Line Voltage 3-phase, L1-L2 Voltage or L1-N voltage inletPoleIndex = 2; 3-phase L2-L3 Voltage or L2-N voltage inletPoleaIndex = 3; 3-phase L3-L1 Voltage or L3-N voltage
1.3.6.1.4.1.13742.4.1.21.2.1.4MilliVoltsread-onlycurrent
inletPoleMaxCurrent
OBJECT-TYPE
This object has an invalid value for a single-phase PDU. If inletPoleCount = 1, then the value is invalid; In all other cases, it is the value of the max. current sensor attached to the inlet Pole. This value is reported in milliamps (1/1000th of an amp)
1.3.6.1.4.1.13742.4.1.21.2.1.5MilliAmpsread-onlycurrent
inletPoleActivePower
OBJECT-TYPE
This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the active power for the line/pole. The value is reported in Watts.
1.3.6.1.4.1.13742.4.1.21.2.1.7Wattsread-onlycurrent
inletPoleApparentPower
OBJECT-TYPE
This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the apparent power for the line/pole. The value is reported in Volt-Amps
1.3.6.1.4.1.13742.4.1.21.2.1.8VoltAmpsread-onlycurrent
inletPolePowerFactor
OBJECT-TYPE
This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the power factor for the line/pole The reading represents a percentage in the range of 0% to 100%.
1.3.6.1.4.1.13742.4.1.21.2.1.9PowerFactorPercentageread-onlycurrent
inletPoleActiveEnergy
OBJECT-TYPE
This object has a valid value only for inline meters. If inlineMeter = 'No', then the value is invalid; In all other cases, it is the cumulative active energy for the line/pole. The value is reported in WattHours
1.3.6.1.4.1.13742.4.1.21.2.1.11WattHoursread-onlycurrent
environmental
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.2
tempSensorCount
OBJECT-TYPE
The number of external temperature sensors (regardless of their current state) present on this pdu. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.1Integer32read-onlydeprecated
tempSensorTable
OBJECT-TYPE
A list of temperature sensor entries. The number of entries is given by the value of tempSensorCount. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.2not-accessibledeprecated
tempSensorEntry
OBJECT-TYPE
An entry containing sensor reading and threshold settings for a particular temperature sensor. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.2.1not-accessibledeprecated
tempSensorIndex
OBJECT-TYPE
A unique value for each temperature sensor. Its value ranges between 1 and tempSensorCount. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.2.1.1Integer32 (1..256)not-accessibledeprecated
tempSensorLabel
OBJECT-TYPE
A settable human-readable label for the external temperature sensor. One possible use for this label is to convey sensor location. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.2.1.2DisplayStringread-writedeprecated
temperature
OBJECT-TYPE
The value of the external temperature sensor reported in tenth degrees celsius. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.2.1.3TenthDegreesCelsiusread-onlydeprecated
tempLowerWarning
OBJECT-TYPE
The value of the lower warning (non-critical) threshold. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.2.1.4DegreesCelsiusread-writedeprecated
tempUpperWarning
OBJECT-TYPE
The value of the upper warning (non-critical) threshold. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.2.1.5DegreesCelsiusread-writedeprecated
tempLowerCritical
OBJECT-TYPE
The value of the lower critical threshold. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.2.1.6DegreesCelsiusread-writedeprecated
tempUpperCritical
OBJECT-TYPE
The value of the upper critical threshold. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.2.1.7DegreesCelsiusread-writedeprecated
tempXCoordinate
OBJECT-TYPE
The value of X coordinate in freeform with number of characters <= 24 This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.2.1.8DisplayStringread-writedeprecated
tempYCoordinate
OBJECT-TYPE
The value of Y coordinate in freeform with number of characters <= 24 This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.2.1.9DisplayStringread-writedeprecated
tempZCoordinate
OBJECT-TYPE
The value of Z coordinate in one of two formats: either freeform with number of characters <= 24 or in Z units so that 0 =< integer value <= 60 This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.2.1.10DisplayStringread-writedeprecated
humiditySensorCount
OBJECT-TYPE
The number of external humidity sensors (regardless of their current state) present on this pdu. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.3Integer32read-onlydeprecated
humiditySensorTable
OBJECT-TYPE
A list of humidity sensor entries. The number of entries is given by the value of humiditySensorCount. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.4not-accessibledeprecated
humiditySensorEntry
OBJECT-TYPE
An entry containing sensor reading and threshold settings for a particular humidity sensor. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.4.1not-accessibledeprecated
humiditySensorIndex
OBJECT-TYPE
A unique value for each humidity sensor. Its value ranges between 1 and humiditySensorCount. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.4.1.1Integer32 (1..256)not-accessibledeprecated
humiditySensorLabel
OBJECT-TYPE
A settable human-readable label for the external humidity sensor. One possible use for this label is to convey sensor location. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.4.1.2DisplayStringread-writedeprecated
humidity
OBJECT-TYPE
The value of the external humidity sensor reported as relative humidity (a percentage). This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.4.1.3RelativeHumidityread-onlydeprecated
humidityLowerWarning
OBJECT-TYPE
The value of the lower warning (non-critical) threshold. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.4.1.4RelativeHumidityread-writedeprecated
humidityUpperWarning
OBJECT-TYPE
The value of the upper warning (non-critical) threshold. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.4.1.5RelativeHumidityread-writedeprecated
humidityLowerCritical
OBJECT-TYPE
The value of the lower critical threshold. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.4.1.6RelativeHumidityread-writedeprecated
humidityUpperCritical
OBJECT-TYPE
The value of the upper critical threshold. This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.4.1.7RelativeHumidityread-writedeprecated
humidityXCoordinate
OBJECT-TYPE
The value of X coordinate in freeform with number of characters <= 24 This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.4.1.8DisplayStringread-writedeprecated
humidityYCoordinate
OBJECT-TYPE
The value of Y coordinate in freeform with number of characters <= 24 This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.4.1.9DisplayStringread-writedeprecated
humidityZCoordinate
OBJECT-TYPE
The value of Z coordinate in one of two formats: either freeform with number of characters <= 24 or in Z units so that 0 =< integer value <= 60 This is deprecated in favor of externalSensors
1.3.6.1.4.1.13742.4.2.4.1.10DisplayStringread-writedeprecated
externalSensors
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.3
externalSensorCount
OBJECT-TYPE
The number of external sensors
1.3.6.1.4.1.13742.4.3.1Integer32 (0..255)read-onlycurrent
reorderexternalSensorTableEntries
OBJECT-TYPE
This is an operation. It has write-only semantics. GET operation will return the empty string. For SET operations, it specifies the new order of the externalSensorTable entries. a) The list must contain entries for each managed sensor, even if the sensor is not being moved. b) The list must not have more than 16 entries. c) 1 <= Valid sensorID <= 16 d) The length of the list is the value of the largest sensorID in the original (before the move) list of managed sensors. e) Each sensorID must appear only once in the list. f) If there are missing numbers in the original list of sensorIDs, then each missing number must be indicated by a comma. EXAMPLE 1: Managed sensors have IDs 1,2,3,4,5 Move 1 to 13; 2 to 8; 3 to 9; 4 is not moved; 5 moves to 2 Existing Position New Position 1 --> 13 2 --> 8 3 --> 9 4 --> 4 5 --> 2 Since the largest sensorID before the move is 5, the length of the list is 5 Comma separated list is 13,8,9,4,2 EXAMPLE 2: Managed sensors have IDs 2,5,6,7,11 Sensor IDs 1,3,4,8,9,10 do not appear in the list. These positions must be indicated by commas. Move 2 to 13; 5 to 8; 6 to 9; 7 to 16; 11 does not move Existing Position New Position 2 --> 13 5 --> 8 6 --> 9 7 --> 16 11 --> 11 Since the largest sensorID before the move is 11, the length of the list is 11 Comma separated list is ,13,,,8,9,16,,,,11
1.3.6.1.4.1.13742.4.3.2DisplayStringread-writecurrent
externalSensorTable
OBJECT-TYPE
A list of externalSensor entries. The number of entries is given by the value of externalSensorCount for the pdu.
1.3.6.1.4.1.13742.4.3.3not-accessiblecurrent
externalSensorEntry
OBJECT-TYPE
An externalSensor entry containing objects at the for a particular PDU.
1.3.6.1.4.1.13742.4.3.3.1not-accessiblecurrent
sensorID
OBJECT-TYPE
A unique value for each sesnor. Its value ranges between 1 and the value of externalSensorCount.
1.3.6.1.4.1.13742.4.3.3.1.1Integer32 (1..256)not-accessiblecurrent
externalSensorType
OBJECT-TYPE
The type of sensor
1.3.6.1.4.1.13742.4.3.3.1.2TypeOfSensorEnumerationread-onlycurrent
externalSensorSerialNumber
OBJECT-TYPE
The sensor serial number
1.3.6.1.4.1.13742.4.3.3.1.3DisplayStringread-onlycurrent
externalSensorName
OBJECT-TYPE
The user given name
1.3.6.1.4.1.13742.4.3.3.1.4DisplayStringread-writecurrent
externalSensorChannelNumber
OBJECT-TYPE
The channel number, applies only to contact sensors; -1 for other sensors
1.3.6.1.4.1.13742.4.3.3.1.5Integer32read-onlycurrent
externalSensorXCoordinate
OBJECT-TYPE
The X coordinate
1.3.6.1.4.1.13742.4.3.3.1.6DisplayStringread-writecurrent
externalSensorYCoordinate
OBJECT-TYPE
The Y coordinate
1.3.6.1.4.1.13742.4.3.3.1.7DisplayStringread-writecurrent
externalSensorZCoordinate
OBJECT-TYPE
The Z coordinate
1.3.6.1.4.1.13742.4.3.3.1.8DisplayStringread-writecurrent
externalBinarySensorSubtype
OBJECT-TYPE
The subtype of the binary sensor This OID is valid for discrete sensors only.
1.3.6.1.4.1.13742.4.3.3.1.9TypeOfSensorEnumerationread-onlycurrent
externalSensorUnits
OBJECT-TYPE
The base units. Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors
1.3.6.1.4.1.13742.4.3.3.1.16SensorUnitsEnumerationread-onlycurrent
externalSensorDecimalDigits
OBJECT-TYPE
The number of digits displayed to the right of the decimal point. Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors
1.3.6.1.4.1.13742.4.3.3.1.17Unsigned32read-onlycurrent
externalSensorLowerCriticalThreshold
OBJECT-TYPE
The lower critical threshold The value of this OID variable should be scaled by externalSensorDecimalDigits. For example, if the value is 1 and externalSensorDecimalDigits is 2, then actual value is .01 Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors
1.3.6.1.4.1.13742.4.3.3.1.31Integer32read-writecurrent
externalSensorLowerWarningThreshold
OBJECT-TYPE
The lower non-critical (warning) threshold The value of this OID variable should be scaled by externalSensorDecimalDigits. For example, if the value is 1 and externalSensorDecimalDigits is 2, then actual value is .01 Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors
1.3.6.1.4.1.13742.4.3.3.1.32Integer32read-writecurrent
externalSensorUpperCriticalThreshold
OBJECT-TYPE
The upper critical threshold The value of this OID variable should be scaled by externalSensorDecimalDigits. For example, if the value is 1 and externalSensorDecimalDigits is 2, then actual value is .01 Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors
1.3.6.1.4.1.13742.4.3.3.1.33Integer32read-writecurrent
externalSensorUpperWarningThreshold
OBJECT-TYPE
The upper non-critical (warning) threshold The value of this OID variable should be scaled by externalSensorDecimalDigits. For example, if the value is 1 and externalSensorDecimalDigits is 2, then actual value is .01 Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors
1.3.6.1.4.1.13742.4.3.3.1.34Integer32read-writecurrent
externalSensorHysteresis
OBJECT-TYPE
The hysteresis used for deassertions The value of this OID variable should be scaled by externalSensorDecimalDigits. For example, if the value is 1 and externalSensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to onOff, trip, vibration, waterDetection, smokeDetection sensors.
1.3.6.1.4.1.13742.4.3.3.1.35Unsigned32read-writecurrent
externalSensorState
OBJECT-TYPE
The sensor state
1.3.6.1.4.1.13742.4.3.3.1.40StateOfSensorEnumerationread-onlycurrent
externalSensorValue
OBJECT-TYPE
The sensor reading Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensors
1.3.6.1.4.1.13742.4.3.3.1.41Integer32read-onlycurrent
conformance
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.9
compliances
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.9.1
groups
OBJECT-IDENTITY
1.3.6.1.4.1.13742.4.9.2

Notifications

NameOIDStatus
rebootStarted
NOTIFICATION-TYPE
The reboot process has started
1.3.6.1.4.1.13742.4.0.1current
rebootCompleted
NOTIFICATION-TYPE
The reboot process is complete
1.3.6.1.4.1.13742.4.0.2current
userLogin
NOTIFICATION-TYPE
A user logged in
1.3.6.1.4.1.13742.4.0.3current
userLogout
NOTIFICATION-TYPE
A user logged out
1.3.6.1.4.1.13742.4.0.4current
userAuthenticationFailure
NOTIFICATION-TYPE
A user authentication attempt failed
1.3.6.1.4.1.13742.4.0.5current
userSessionTimeout
NOTIFICATION-TYPE
A user timed out from the device
1.3.6.1.4.1.13742.4.0.8current
userAdded
NOTIFICATION-TYPE
A user was added to the system
1.3.6.1.4.1.13742.4.0.11current
userModified
NOTIFICATION-TYPE
A user account was modified
1.3.6.1.4.1.13742.4.0.12current
userDeleted
NOTIFICATION-TYPE
A user was deleted from the system
1.3.6.1.4.1.13742.4.0.13current
groupAdded
NOTIFICATION-TYPE
A group was added to the system
1.3.6.1.4.1.13742.4.0.14current
groupModified
NOTIFICATION-TYPE
A group was modified
1.3.6.1.4.1.13742.4.0.15current
groupDeleted
NOTIFICATION-TYPE
A group was deleted from the system
1.3.6.1.4.1.13742.4.0.16current
deviceUpdateStarted
NOTIFICATION-TYPE
The device update has started
1.3.6.1.4.1.13742.4.0.20current
userBlocked
NOTIFICATION-TYPE
A blocked user tried to log in
1.3.6.1.4.1.13742.4.0.22current
powerControl
NOTIFICATION-TYPE
An outlet has been switched
1.3.6.1.4.1.13742.4.0.23current
userPasswordChanged
NOTIFICATION-TYPE
A user password was changed
1.3.6.1.4.1.13742.4.0.24current
passwordSettingsChanged
NOTIFICATION-TYPE
Strong password settings changed
1.3.6.1.4.1.13742.4.0.28current
firmwareFileDiscarded
NOTIFICATION-TYPE
A firmware file discarded
1.3.6.1.4.1.13742.4.0.36current
firmwareValidationFailed
NOTIFICATION-TYPE
A firmware validation failed
1.3.6.1.4.1.13742.4.0.38current
securityViolation
NOTIFICATION-TYPE
Security violation.
1.3.6.1.4.1.13742.4.0.39current
logFileCleared
NOTIFICATION-TYPE
The log file has been cleared.
1.3.6.1.4.1.13742.4.0.41current
thresholdAlarm
NOTIFICATION-TYPE
Configured sensor theshold event. The 'thresholdEventType' variable will indicate whether or not the threshold triggered or cleared. thresholdValue and sensorValue have valid values only for external temperature and humidity sensors.
1.3.6.1.4.1.13742.4.0.45current
outletGroupingConnectivityLost
NOTIFICATION-TYPE
Master PDU lost contact with the slave PDU in an outlet grouping configuration.
1.3.6.1.4.1.13742.4.0.50current
circuitBreakerTripped
NOTIFICATION-TYPE
Circuit Breaker Tripped.
1.3.6.1.4.1.13742.4.0.51current
circuitBreakerRecovered
NOTIFICATION-TYPE
Circuit Breaker Recovered.
1.3.6.1.4.1.13742.4.0.52current
bulkConfigurationSaved
NOTIFICATION-TYPE
Bulk Configuration saved.
1.3.6.1.4.1.13742.4.0.53current
bulkConfigurationCopied
NOTIFICATION-TYPE
Bulk Configuration saved.
1.3.6.1.4.1.13742.4.0.54current
environmentalSensorsConnectivityLost
NOTIFICATION-TYPE
lost connectivity to environmental Sensors
1.3.6.1.4.1.13742.4.0.55current
externalOnOffSensorStateChange
NOTIFICATION-TYPE
External OnOff Sensor State Change.
1.3.6.1.4.1.13742.4.0.56current
environmentalSensorsConnectivityRestored
NOTIFICATION-TYPE
connectivity to environmental Sensor was restored
1.3.6.1.4.1.13742.4.0.57current
voltageMeasurementError
NOTIFICATION-TYPE
voltage measurement error, a Psoc (Outlet Controller) reported zero voltage and non-zero current. Voltage, power and energy measurements may be in error
1.3.6.1.4.1.13742.4.0.58current
fipsModeEnabled
NOTIFICATION-TYPE
FIPS Mode Enabled
1.3.6.1.4.1.13742.4.0.59current
fipsModeDisabled
NOTIFICATION-TYPE
FIPS Mode Disabled
1.3.6.1.4.1.13742.4.0.60current
managingenvironmentalSensor
NOTIFICATION-TYPE
begin managing environmental Sensor
1.3.6.1.4.1.13742.4.0.61current
unmanagingenvironmentalSensor
NOTIFICATION-TYPE
cease managing environmental Sensor
1.3.6.1.4.1.13742.4.0.62current
ipmiOverLANEnabled
NOTIFICATION-TYPE
IPMI Over LAN Mode has been Enabled
1.3.6.1.4.1.13742.4.0.63current
ipmiOverLANDisabled
NOTIFICATION-TYPE
IPMI Over LAN Mode has been Disabled
1.3.6.1.4.1.13742.4.0.64current

Conformance

NameOIDStatus
compliance
MODULE-COMPLIANCE
The requirements for conformance to the PDU-MIB. This is deprecated and the new compliance ComplianceRev1 has been added
1.3.6.1.4.1.13742.4.9.1.1deprecated
complianceRev1
MODULE-COMPLIANCE
The requirements for conformance to the PDU-MIB. This is deprecated and the new compliance ComplianceRev2 has been added
1.3.6.1.4.1.13742.4.9.1.2deprecated
complianceRev2
MODULE-COMPLIANCE
The requirements for conformance to the PDU-MIB. This is deprecated and the new compliance ComplianceRev3 has been added
1.3.6.1.4.1.13742.4.9.1.3deprecated
complianceRev3
MODULE-COMPLIANCE
The requirements for conformance to the PDU-MIB.This is deprecated and the new compliance ComplianceRev4 has been added
1.3.6.1.4.1.13742.4.9.1.4deprecated
complianceRev4
MODULE-COMPLIANCE
The requirements for conformance to the PDU-MIB. This is deprecated and the new compliance ComplianceRev5 has been added
1.3.6.1.4.1.13742.4.9.1.5deprecated
complianceRev5
MODULE-COMPLIANCE
The requirements for conformance to the PDU-MIB.
1.3.6.1.4.1.13742.4.9.1.6current
infoGroup
OBJECT-GROUP
A collection of objects providing basic information about the pdu.
1.3.6.1.4.1.13742.4.9.2.1deprecated
outletsGroup
OBJECT-GROUP
A collection of objects providing basic information about the outlets, including sensor readings.
1.3.6.1.4.1.13742.4.9.2.2current
unitSensorsGroup
OBJECT-GROUP
A collection of objects providing unit level sensor readings.This group is deprecated in favor of unitSensorsGroupRev
1.3.6.1.4.1.13742.4.9.2.4deprecated
externalTemperatureGroup
OBJECT-GROUP
A collection of objects providing external temperature sensor readings and threshold settings. This group is deprecated in favor of the externalSensorsGroup
1.3.6.1.4.1.13742.4.9.2.6deprecated
externalHumidityGroup
OBJECT-GROUP
A collection of objects providing external humidity sensor readings and threshold settings. This group is deprecated in favor of the externalSensorsGroup
1.3.6.1.4.1.13742.4.9.2.7deprecated
trapsGroup
NOTIFICATION-GROUP
A collection of traps.
1.3.6.1.4.1.13742.4.9.2.9current
lineCurrentGroup
OBJECT-GROUP
A collection of objects describing the line inputs. This group is deprecated in favor of inletPoleGroup
1.3.6.1.4.1.13742.4.9.2.10deprecated
circuitBreakerGroup
OBJECT-GROUP
A collection of objects describing the circuit breakers.
1.3.6.1.4.1.13742.4.9.2.11current
lineVoltageGroup
OBJECT-GROUP
A collection of objects describing the line voltages. This group is deprecated in favor of inletPoleGroup
1.3.6.1.4.1.13742.4.9.2.12deprecated
unitSensorsGroupRev
OBJECT-GROUP
A collection of objects providing unit level sensor readings.This group is deprecated in favor of unitSensorsGroupRev2
1.3.6.1.4.1.13742.4.9.2.13deprecated
dataLogGroup
OBJECT-GROUP
A collection of objects describing the pdu data. This group is being deprecated in favor of dataLogGroupRev
1.3.6.1.4.1.13742.4.9.2.14deprecated
inletPoleGroup
OBJECT-GROUP
A collection of objects describing the inlet poles.
1.3.6.1.4.1.13742.4.9.2.15current
inletsGroup
OBJECT-GROUP
A collection of objects providing basic information about the inlets, including sensor readings.
1.3.6.1.4.1.13742.4.9.2.16current
dataLogGroupRev
OBJECT-GROUP
A collection of objects describing the pdu data. This group is being deprecated in favor of dataLogGroupRev2
1.3.6.1.4.1.13742.4.9.2.17deprecated
unitSensorsGroupRev2
OBJECT-GROUP
A collection of objects providing unit level sensor readings.
1.3.6.1.4.1.13742.4.9.2.18current
externalSensorsGroup
OBJECT-GROUP
A collection of objects providing external sensor readings and configuration settings.
1.3.6.1.4.1.13742.4.9.2.20current
dataLogGroupRev2
OBJECT-GROUP
A collection of objects describing the pdu data.
1.3.6.1.4.1.13742.4.9.2.21current
infoGroupRev2
OBJECT-GROUP
A collection of objects providing basic information about the pdu.
1.3.6.1.4.1.13742.4.9.2.22current