MIBs Depot

PDN-LINK-FAULT-MGMT-MIB

Registered at
1.3.6.1.4.1.1795.2.24.2.40.1
Last updated
2003-04-03 19:00
Organization
Paradyne Corporation MIB Working Group
Revisions
2003-04-23 18:00
Namespace
zhone
Source file
PDN-LINK-FAULT-MGMT-MIB
Digest
sha256:ad0dcce025415cbf6eec61ccb37b3a649933be7f17c3ff4f5de36167e03c7710

Description

This management information module supports the objects to be used for fault management configuration on primary and secondary links.

Contact

Paradyne Networks Inc. Postal: 8545, 126th Ave. N. Largo, FL 33779 US Editor: Jesus Pinto Email: mibwg_team@eng.paradyne.com

Imports

FromSymbols
IF-MIBifIndex
PDN-HEADER-MIBpdnLinkFaultMgmt
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
PDN-HEADER-MIB
PDN-LINK-FAULT-MGMT-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
pdnLinkFaultMgmtMIBObjects
OBJECT-IDENTITY
1.3.6.1.4.1.1795.2.24.2.40.1.1
pdnLinkFaultMgmtApsSelection
OBJECT-TYPE
This object is used to enable or disable the Automatic Protection Switching (Aps) feature on this device. This object can not be enabled if the -Switchover due to link failures- is enabled.
1.3.6.1.4.1.1795.2.24.2.40.1.1.1INTEGER {enabled(1), disabled(2)}read-writecurrent
pdnLinkFaultMgmtSwitchoverSelection
OBJECT-TYPE
This object is used to enable or disable the Switchover Due to link failures feature on on this device. This object can not be enabled if the APS feature is enabled.
1.3.6.1.4.1.1795.2.24.2.40.1.1.2INTEGER {enabled(1), disabled(2)}read-writecurrent
pdnLinkFailureConfigTable
OBJECT-TYPE
This table contains one row per link being monitored for link failures.
1.3.6.1.4.1.1795.2.24.2.40.1.1.3not-accessiblecurrent
pdnLinkFailureConfigEntry
OBJECT-TYPE
Configuration information about a particular interface being monitored for link failured.
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1not-accessiblecurrent
pdnLinkFailureLOSPeriodBeforeSwitching
OBJECT-TYPE
This object allows users to configure the amount of time a LOS condition shall exist on this uplink before initiating a switchover. Switchover due to LOS condition on this uplink will not be valid if any of the APS (Automatic Protection Switching) is enabled.
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.1Integer32 (0..300)read-writecurrent
pdnLinkFailureLOFPeriodBeforeSwitching
OBJECT-TYPE
This object allows users to configure the amount of time a LOF condition shall exist on this uplink before initiating a switchover. Switchover due to LOF condition on this uplink will not be valid if any of the APS (Automatic Protection Switching) is enabled.
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.2Integer32 (0..300)read-writecurrent
pdnLinkFailureAISLPeriodBeforeSwitching
OBJECT-TYPE
This object allows users to configure the amount of time a AIS-L condition shall exist on this uplink before initiating a switchover. Switchover due to AIS-L condition on this uplink will not be valid if any of the APS (Automatic Protection Switching) is enabled.
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.3Integer32 (0..300)read-writecurrent
pdnLinkFailureSdPeriodBeforeSwitching
OBJECT-TYPE
This object allows users to configure the amount of time a Signal Degraded (Sd) condition shall exist on this uplink before initiating a switchover. Switchover due to Sd condition on this uplink will not be valid if any of the APS (Automatic Protection Switching) is enabled.
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.4Integer32 (0..300)read-writecurrent
pdnLinkFailureSfPeriodBeforeSwitching
OBJECT-TYPE
This object allows users to configure the amount of time a Signal Failure Bit (Sf) condition shall exist on this uplink before initiating a switchover. Switchover due to Sf condition on this uplink will not be valid if any of the APS (Automatic Protection Switching) is enabled.
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.5Integer32 (0..300)read-writecurrent
pdnLinkFailureSdBerThreshold
OBJECT-TYPE
This object allows users to configure the threshold for the Signal Degrade Bit Error Rate (Sd). The negated value of this number is used as the exponent of 10 for computing the threshold value for the Bit Error Rate (BER). For example, a value of 5 indicates a BER threshold of 10^-5.
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.6Integer32 (5..9)read-writecurrent
pdnLinkFailureSfBerThreshold
OBJECT-TYPE
This object allows users to configure the threshold for the Signal Failure Bit Error Rate (Sf). The negated value of this number is used as the exponent of 10 for computing the threshold value for the Bit Error Rate (BER). For example, a value of 5 indicates a BER threshold of 10^-5.
1.3.6.1.4.1.1795.2.24.2.40.1.1.3.1.7Integer32 (3..5)read-writecurrent
pdnDualLinkSelection
OBJECT-TYPE
This object is used to enable or disable the ability to split traffic among dual links.
1.3.6.1.4.1.1795.2.24.2.40.1.1.4INTEGER {enabled(1), disabled(2)}read-writecurrent
pdnLinkFaultMgmtMIBConformance
OBJECT-IDENTITY
1.3.6.1.4.1.1795.2.24.2.40.1.2
pdnLinkFaultMgmtCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.1795.2.24.2.40.1.2.1
pdnLinkFaultMgmtGroups
OBJECT-IDENTITY
1.3.6.1.4.1.1795.2.24.2.40.1.2.2

Conformance

NameOIDStatus
pdnLinkFaultMgmtCompliance
MODULE-COMPLIANCE
The compliance statement for SNMP entities capable of configuring link fault conditions.
1.3.6.1.4.1.1795.2.24.2.40.1.2.1.1current
pdnLinkFaultMgmtGeneralGroup
OBJECT-GROUP
A collection of configuration objects applicable to link fault mgmt implementation.
1.3.6.1.4.1.1795.2.24.2.40.1.2.2.1current
pdnLinkSwitchoverGroup
OBJECT-GROUP
A collection of configuration objects applicable to all redundancy implementations.
1.3.6.1.4.1.1795.2.24.2.40.1.2.2.2current