Description

The Paradyne enterprise DS1/G.703 extension MIB. This MIB provides additional DS1 and G.703 (E1) configuration objects not provided by rfc2495.

Contact

Paradyne Networks, Inc. 8545, 126th Ave. N., Largo, FL 33779 www.paradyne.com General Comments to: mibwg_team@paradyne.com Editors: Vic Sperry

Imports

FromSymbols
IF-MIBifIndex
PDN-HEADER-MIBent-ds1
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
PDN-DS1EXT-MIB
PDN-HEADER-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
pdnDs1ExtObjects
OBJECT-IDENTITY
1.3.6.1.4.1.1795.2.24.2.6.5.5.1
pdnDs1ExtConfTable
OBJECT-TYPE
The Paradyne DS1/G.703 extension configuration table. This table is used for configuring extensions to DS1 and G.703 interfaces.
1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1not-accessiblecurrent
pdnDs1ExtConfEntry
OBJECT-TYPE
An entry in the Paradyne DS1/G.703 extension configuration table. Note: The objects used depend on the type of interface. For DS1: use pdnDs1ExtConfLineLengthType and one of (pdnDs1ExtConfLineLength or pdnDs1ExtConfLineBuildOut) For G.703: use pdnDs1ExtConfLineLengthType and pdnDs1ExtConfConnector
1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1not-accessiblecurrent
pdnDs1ExtConfLineLengthType
OBJECT-TYPE
This entry specifies the type of loop length for the interface. short-haul is intended for intra-building use. long-haul is intended for inter-building use.
1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1.1INTEGER {shortHaul(1), longHaul(2)}read-writecurrent
pdnDs1ExtConfLineLength
OBJECT-TYPE
This entry specifies the loop length, in feet, for a short-haul DS1 line. This object only applies to DS1 interfaces. Note: This object shares a mutually exclusive relationship with the pdnDs1ExtConfLineBuildOut object i.e. only one of the two can be used for configuration at one time, based on the pdnDs1ExtConfLineLengthType object.
1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1.2INTEGER {feet000To133(1), feet134To266(2), feet267To399(3), feet400To533(4), feet534To655(5)}read-writecurrent
pdnDs1ExtConfLineBuildOut
OBJECT-TYPE
This entry specifies the line build out, in decibels, for a long-haul DS1 line. dB0Pnt0 = 0.0 dB dB7Pnt5 = -7.5 dB dB15Pnt0 = -15.0 dB dB22Pnt5 = -22.5 dB This object only applies to DS1 interfaces. Note: This object shares a mutually exclusive relationship with the pdnDs1ExtConfLineLength object i.e. only one of the two can be used for configuration at one time, based on the pdnDs1ExtConfLineLengthType object.
1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1.3INTEGER {dB0Pnt0(1), dB7Pnt5(2), dB15Pnt0(3), dB22Pnt5(4)}read-writecurrent
pdnDs1ExtConfConnector
OBJECT-TYPE
This entry specifies the type of connector to be used. This object only applies to G.703 interfaces. bnc: 75-Ohm connector supporting only short-haul. rj48: 120-Ohm connector supporting both short-haul and long-haul.
1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1.4INTEGER {bnc(1), rj48(2)}read-writecurrent
pdnDs1ExtConformance
OBJECT-IDENTITY
1.3.6.1.4.1.1795.2.24.2.6.5.5.2
pdnDs1ExtGroups
OBJECT-IDENTITY
1.3.6.1.4.1.1795.2.24.2.6.5.5.2.1
pdnDs1ExtCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.1795.2.24.2.6.5.5.2.2

Conformance

NameOIDStatus
pdnDs1ExtT1ConfigGroup
OBJECT-GROUP
A collection of configuration objects required for configuring a T1 interface.
1.3.6.1.4.1.1795.2.24.2.6.5.5.2.1.1current
pdnDs1ExtE1ConfigGroup
OBJECT-GROUP
A collection of configuration objects required for configuring a G.703 (E1) interface.
1.3.6.1.4.1.1795.2.24.2.6.5.5.2.1.2current
pdnDs1ExtCompliance
MODULE-COMPLIANCE
Compliance statement for using this MIB for configuring DS1 interfaces.
1.3.6.1.4.1.1795.2.24.2.6.5.5.2.2.1current
pdnDs1ExtG703Compliance
MODULE-COMPLIANCE
Compliance statement for using this MIB for configuring G.703 interfaces.
1.3.6.1.4.1.1795.2.24.2.6.5.5.2.2.2current