PDN-DIAGNOSTICS-MIB
- Registered at
- 1.3.6.1.4.1.1795.2.24.2.16.11.3.6.1.4.1.1795.2.24.2.16.2
- Namespace
- zhone
- Source file
PDN-DIAGNOSTICS-MIB- Digest
sha256:508112dc08340370d1b8bdf6690c94eb0e75fc29bad9dd6620ee91f8ba8c8185
Imports
| From | Symbols |
|---|---|
| IF-MIB | ifIndex, ifTestId |
| PDN-HEADER-MIB | pdn-diagnostics |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, iso |
| SNMPv2-TC | AutonomousType, DisplayString, RowStatus, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB IF-MIB PDN-DIAGNOSTICS-MIB PDN-HEADER-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| diagTestMIBObjects OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.16.1 | |||
| diagIfTest OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.16.1.1 | |||
| ifLoopbackTestTable OBJECT-TYPE This table contains input and results of a packet loopback test. This table is indexed by ifIndex. This is a interface related test. There can be only one test running per interface. This table should be used in conjunction with ifTestTable(Rfc 1573) with all the semantics of ifTestTable. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.1 | not-accessible | mandatory | |
| ifLoopbackTestEntry OBJECT-TYPE An entry containing objects for test input and result for packet loopback test | 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1 | not-accessible | mandatory | |
| loopbackTestInputNumCycles OBJECT-TYPE This object corresponds the number of cycles the test to be run for. One cycle corresponds to a 15 second interval. The default value for this object is 40. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.1 | INTEGER | read-write | mandatory |
| loopbackTestResultsPktsSent OBJECT-TYPE This object corresponds to the number of packets sent | 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.2 | INTEGER | read-only | mandatory |
| loopbackTestResultsPktsRcvdOK OBJECT-TYPE This object corresponds to the number of packets which were received without any error | 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.3 | INTEGER | read-only | mandatory |
| loopbackTestResultsPktsRcvdErr OBJECT-TYPE This object corresponds to the number of packets which were received with errors | 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.4 | INTEGER | read-only | mandatory |
| loopbackTestResultsPktsNotRcvd OBJECT-TYPE This object corresponds to the number of packets which were sent but not received | 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.5 | INTEGER | read-only | mandatory |
| loopbackTestResultsPktErrorRate OBJECT-TYPE Reflects the error rate of the loopback test. this string will represent a floating point number of the form [ErrRate][eE][+-][ErrRateBase] where ErrRate and ErrRateBase are integers. In Other Words ErrRate * [10^ -ErrRateBase] shown below are example of the values returned. 123456E-5 = 1.23456 344567e-6 = 0.344567 | 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.6 | DisplayString (SIZE(1..32)) | read-only | mandatory |
| loopbackTestResultsErrSecs OBJECT-TYPE This object corresponds to the number of errored seconds | 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.7 | INTEGER | read-only | mandatory |
| loopbackTestResultsSvrErrSecs OBJECT-TYPE This object corresponds to the number of severely errored seconds | 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.8 | INTEGER | read-only | mandatory |
| loopbackTestResultsElpTime OBJECT-TYPE This object corresponds to the number of seconds elapsed since the start of the test. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.1.1.9 | INTEGER | read-only | mandatory |
| ifBERTObjectsTable OBJECT-TYPE This table contains the objects for Bit Error Rate Test. This table is indexed by ifIndex. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2 | not-accessible | mandatory | |
| ifBERTObjectsEntry OBJECT-TYPE An Entry containing objects of BERT. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1 | not-accessible | mandatory | |
| ifBERTTestDuration OBJECT-TYPE This object represents the test duration in seconds. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.1 | INTEGER | read-write | mandatory |
| ifBERTElapsedTime OBJECT-TYPE This object represents the elapsed time in seconds. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.2 | INTEGER | read-only | mandatory |
| ifBERTDownSyncUP OBJECT-TYPE This object indicates whether Downstream sync is enabled . | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.3 | INTEGER {yes(1), no(2)} | read-only | mandatory |
| ifBERTUpSyncUP OBJECT-TYPE This object indicates whether upstream sync is enabled. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.4 | INTEGER {yes(1), no(2)} | read-only | mandatory |
| ifBERTSegmentsSent OBJECT-TYPE This object represents the number of segments sent during the test | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.5 | INTEGER | read-only | mandatory |
| ifBERTDownMBitsRcvd OBJECT-TYPE This represents the number of million bits rcvd downstream. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.6 | INTEGER | read-only | mandatory |
| ifBERTUpMBitsRcvd OBJECT-TYPE This represents the number of million bits rcvd upstream. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.7 | INTEGER | read-only | mandatory |
| ifBERTDownBitErrDetected OBJECT-TYPE This represents the number of bit errors detected downstream. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.8 | INTEGER | read-only | mandatory |
| ifBERTUpBitErrDetected OBJECT-TYPE This represents the number of bit errors detected upstream. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.9 | INTEGER | read-only | mandatory |
| ifBERTDownBitErrRate OBJECT-TYPE This string will represent a floating point number of the form [Er rRate] [eE] [+-] [ErrRatebase] where ErrTare and errRateBase are integers. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.10 | DisplayString (SIZE(1..32)) | read-only | mandatory |
| ifBERTUpBitErrRate OBJECT-TYPE This object reflects the error rate of BERT in Upstream direction. This string will represent a floating point number of the form [ErrRate] [eE] [+-] [ErrRatebase] where ErrTare and errRateBase are integers. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.11 | DisplayString (SIZE(1..32)) | read-only | mandatory |
| ifBERTDownErroredSecs OBJECT-TYPE This represents number of errored seconds downstream. Errored second is a second in which there is at least 1 block error. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.12 | INTEGER | read-only | mandatory |
| ifBERTUpErroredSecs OBJECT-TYPE This represents number of errored seconds upstream. Errored second is a second in which there is at least 1 block error. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.13 | INTEGER | read-only | mandatory |
| ifBERTDownLineRate OBJECT-TYPE This represents the downstream line rate in KBPS | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.14 | INTEGER | read-only | mandatory |
| ifBERTUpLineRate OBJECT-TYPE This represents the Upstream line rate in KBPS | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.15 | INTEGER | read-only | mandatory |
| ifBERTDownMargin OBJECT-TYPE This represents the Downstream margin in decibels (DB). | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.16 | INTEGER | read-only | mandatory |
| ifBERTUpMargin OBJECT-TYPE This represents the upstream margin in decibels (DB). | 1.3.6.1.4.1.1795.2.24.2.16.1.1.2.1.17 | INTEGER | read-only | mandatory |
| ifBLERTObjectsTable OBJECT-TYPE This table contains the objects for Block Error Rate Test (BLERT). This table is indexed by ifIndex. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.3 | not-accessible | mandatory | |
| ifBLERTObjectsEntry OBJECT-TYPE An Entry containing objects of BLERT. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1 | not-accessible | mandatory | |
| ifBLERTTestDuration OBJECT-TYPE This object represents the test duration in seconds. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.1 | INTEGER | read-write | mandatory |
| ifBLERTElapsedTime OBJECT-TYPE This object represents the elapsed time in seconds since the test started. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.2 | INTEGER | read-only | mandatory |
| ifBLERTTxSeqCount OBJECT-TYPE This object indicates the next Tx sequence. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.3 | INTEGER | read-only | mandatory |
| ifBLERTRxSeqCount OBJECT-TYPE This object indicates the next Rx sequence. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.4 | INTEGER | read-only | mandatory |
| ifBLERTRxGoodFrames OBJECT-TYPE This object indicates the number of good frames received. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.5 | INTEGER | read-only | mandatory |
| ifBLERTTxGoodFrames OBJECT-TYPE This object indicates the number of good frames transmitted. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.6 | INTEGER | read-only | mandatory |
| ifBLERTRxBadFrames OBJECT-TYPE This object indicates the number of bad frames received. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.7 | INTEGER | read-only | mandatory |
| ifBLERTTxBadFrames OBJECT-TYPE This object indicates the number of bad frames transmitted. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.8 | INTEGER | read-only | mandatory |
| ifBLERTDnLineRate OBJECT-TYPE This object indicates the downstream line rate. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.9 | INTEGER | read-only | mandatory |
| ifBLERTUpLineRate OBJECT-TYPE This object indicates the upstream line rate. | 1.3.6.1.4.1.1795.2.24.2.16.1.1.3.1.10 | INTEGER | read-only | mandatory |
| diagApplTest OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.16.1.2 | |||
| applMaxNumberOfTests OBJECT-TYPE This object identifies the maximum number of application based tests that can be simultaneously instantiated on the device. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.1 | INTEGER | read-only | mandatory |
| applCurrentNumberOfTests OBJECT-TYPE This object identifies the current number of application based tests that are running on the device. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.2 | INTEGER | read-only | mandatory |
| applStopAllTests OBJECT-TYPE The value of this object corresponds to stop all application based tests on the device. noOp -- no operation stop -- all the application tests will be stopped but current test results are still available stopAndClear -- all the application tests will be stoped and the results are cleared also | 1.3.6.1.4.1.1795.2.24.2.16.1.2.3 | INTEGER {noOp(1), stop(2), stopAndClear(3)} | read-write | mandatory |
| applNewTestId OBJECT-TYPE This value of this object corresponds to getting a magic number to start an application based test. The magic number is used as an index to create a row for the diagApplTestTable. If no new rows can be created, this object will have a value of 0. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.4 | INTEGER | read-only | mandatory |
| applTestStatusTable OBJECT-TYPE This table controls all the application tests. It defines a test type, starts a test, and clears a test. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.5 | not-accessible | mandatory | |
| applTestStatusEntry OBJECT-TYPE An entry containing objects for invoking application based tests | 1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1 | not-accessible | mandatory | |
| applTestId OBJECT-TYPE A unique ID to identify each application test. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.1 | INTEGER | read-only | mandatory |
| applTestType OBJECT-TYPE This object defines the application test type. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.2 | AutonomousType | read-write | mandatory |
| applTestStatus OBJECT-TYPE This object shows the current status of an application test. none - indicates waiting for test parameters. inProgress - indicates the test is in process. success - indicates the test is completed. failed - indicates the test is failed. abort - indicates the test was aborted | 1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.3 | INTEGER {none(1), inProgress(2), success(3), failed(4), abort(5)} | read-only | mandatory |
| applTestErrorCode OBJECT-TYPE This object shows the reason for a test failure. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.4 | INTEGER {none(1), timeout(2), icmpError(3), systemError(4)} | read-only | mandatory |
| applTestOwner OBJECT-TYPE The network manager who has started the test | 1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.5 | DisplayString (SIZE(1..40)) | read-write | mandatory |
| applTestRowStatus OBJECT-TYPE This object is used to create a new row or delete an existing row for an application test. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.5.1.6 | RowStatus | read-write | mandatory |
| applPingTestTable OBJECT-TYPE This table contains objects which allow network manager to ping a destination. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.6 | not-accessible | mandatory | |
| applPingTestEntry OBJECT-TYPE This table contains the input parameters for a ping test and the results of the ping test. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1 | not-accessible | mandatory | |
| applPingTestId OBJECT-TYPE A unique ID to identify each application test. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.1 | INTEGER | read-only | mandatory |
| applPingTestIpAddress OBJECT-TYPE The IP address to be pinged. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.2 | IpAddress | read-write | mandatory |
| applPingTestSourceIpAddr OBJECT-TYPE The Source IP address where we are pinging from. This is an optional object for some devices. See operational specification for its use. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.3 | IpAddress | read-write | mandatory |
| applPingTestPacketSize OBJECT-TYPE This object corresponds to the size of the packet (in bytes) which will be sent during the Ping test. The default value for this object is 64 bytes | 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.4 | INTEGER | read-write | mandatory |
| applPingTestTimeout OBJECT-TYPE This object corresponds to a timeout value (in seconds) between Pings. The default value for this object is 5 seconds | 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.5 | INTEGER | read-write | mandatory |
| applPingTestMaxPings OBJECT-TYPE This object corresponds to the maximum number of times the device should Ping for the destination. The default value for this object is 10 | 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.6 | INTEGER | read-write | mandatory |
| applPingTestPktsSent OBJECT-TYPE This object corresponds to the total number of packets sent. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.7 | INTEGER | read-only | mandatory |
| applPingTestPktsRecv OBJECT-TYPE This object corresponds to the total number of packets received without error | 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.8 | INTEGER | read-only | mandatory |
| applPingTestMinTime OBJECT-TYPE The minimum round trip time. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.9 | INTEGER | read-only | mandatory |
| applPingTestMaxTime OBJECT-TYPE The maximum round trip time. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.10 | INTEGER | read-only | mandatory |
| applPingTestAvgTime OBJECT-TYPE The average round trip time. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.11 | INTEGER | read-only | mandatory |
| applPingTestDomain OBJECT-TYPE This object specifies the destination ip address's domain. The Default is service domain. Not allowed if source ip address is entered. This is an optional object for some devices. See operational specification its use. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.12 | INTEGER {noop(1), mgmt(2), service(3)} | read-write | mandatory |
| applPingTestIfIndex OBJECT-TYPE This object specifies the interface over which the ping test will take place. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.6.1.13 | INTEGER | read-write | mandatory |
| applTracerouteConfigTable OBJECT-TYPE This table contains objects which allow network manager to enter the parameters of a traceroute test. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.7 | not-accessible | mandatory | |
| applTracerouteConfigEntry OBJECT-TYPE This table contains the input parameters for a traceroute test. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1 | not-accessible | mandatory | |
| applTracerouteTestId OBJECT-TYPE A unique ID to identify each application test. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.1 | INTEGER | read-only | mandatory |
| applTracerouteIpAddress OBJECT-TYPE The destination IP address of a traceroute test. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.2 | IpAddress | read-write | mandatory |
| applTracerouteSourceIpAddr OBJECT-TYPE The source IP address of where the traceroute test started. This is an optional object for some devices. See operational specification for its use. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.3 | IpAddress | read-write | mandatory |
| applTraceroutePktsSize OBJECT-TYPE This object corresponds to the size of the packet (in bytes) which will be sent during the traceroute test. Please refer to product specific documentation for the default values supported | 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.4 | INTEGER | read-write | mandatory |
| applTracerouteTimeout OBJECT-TYPE This object corresponds to a timeout value (in seconds) of a traceroute test. The default value for this object is 5 seconds | 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.5 | INTEGER | read-write | mandatory |
| applTracerouteMaxHops OBJECT-TYPE This object corresponds to the maximum number of hops to reach the destination. The default value for this object is device specific. See Operational Specifications | 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.6 | INTEGER | read-write | mandatory |
| applTracerouteDomain OBJECT-TYPE This object specifies the destination ip address's domain. The Default is service domain. Not allowed if source ip address is entered. This is an optional object for some devices. See operational specification its use. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.7 | INTEGER {noop(1), mgmt(2), service(3)} | read-write | mandatory |
| applTracerouteIfIndex OBJECT-TYPE This object specifies the interface over which the trace-route test will take place. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.7.1.8 | INTEGER | read-write | mandatory |
| applTracerouteResultTable OBJECT-TYPE This table contains results of traceroute test. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.8 | not-accessible | mandatory | |
| applTracerouteResultEntry OBJECT-TYPE An entry contains the objects for the traceroute test. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1 | not-accessible | mandatory | |
| applTracerouteResultTestId OBJECT-TYPE A unique ID to identify each application test. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.1 | INTEGER | read-only | mandatory |
| applTracerouteHopCount OBJECT-TYPE This object contains the number of hops to reach the gateway. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.2 | INTEGER | read-only | mandatory |
| applTracerouteIpAddr OBJECT-TYPE This object contains the IP address of the gateway. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.3 | IpAddress | read-only | mandatory |
| applTraceroutePktSize OBJECT-TYPE This object corresponds to the size of the packet (in bytes) which will be sent during the traceroute test. Please refer to product specific documentation for the default values supported | 1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.4 | INTEGER | read-only | mandatory |
| applTracerouteProbe1RTT OBJECT-TYPE This object contains the round trip time (rtt) of the first probe sent to the gateway. If the probe has a timeout the rtt is set to -1. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.5 | INTEGER | read-only | mandatory |
| applTracerouteProbe2RTT OBJECT-TYPE This object contains the round trip time (rtt) of the second probe sent to the gateway. If the probe has a timeout the rtt is set to -1. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.6 | INTEGER | read-only | mandatory |
| applTracerouteProbe3RTT OBJECT-TYPE This object contains the round trip time (rtt) of the third probe sent to the gateway. If the probe has a timeout the rtt is set to -1. | 1.3.6.1.4.1.1795.2.24.2.16.1.2.8.1.7 | INTEGER | read-only | mandatory |
| diagTest OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.16.1.3 | |||
| diagTestTrapEnable OBJECT-TYPE This object is used to disable or enable TestOver and TestStart trap for all tests. It is bit sum and possible bit positions are 1 TestStart trap 2 TestOver trap | 1.3.6.1.4.1.1795.2.24.2.16.1.3.1 | INTEGER | read-write | mandatory |
| diagTestMIBTraps OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.16.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| diagApplTestStart NOTIFICATION-TYPE This trap signifies that an application test has been initiated. | 1.3.6.1.4.1.1795.2.24.2.16.2.0.1 | |
| diagIfTestStart NOTIFICATION-TYPE This trap signifies that a diagnostic test has been initiated. | 1.3.6.1.4.1.1795.2.24.2.16.2.0.2 | |
| diagApplTestStop NOTIFICATION-TYPE This trap signifies that an application test has completed. This trap compliments the diagApplTestStart trap. | 1.3.6.1.4.1.1795.2.24.2.16.2.0.101 | |
| diagIfTestOver NOTIFICATION-TYPE This trap signifies that a diagnostic test has completed. This trap compliments the diagIfTestStart trap | 1.3.6.1.4.1.1795.2.24.2.16.2.0.102 |