PDN-CONFIG-MIB
- Registered at
- 1.3.6.1.4.1.1795.2.24.2.7.11.3.6.1.4.1.1795.2.24.2.7.21.3.6.1.4.1.1795.2.24.2.7.31.3.6.1.4.1.1795.2.24.2.7.41.3.6.1.4.1.1795.2.24.2.7.51.3.6.1.4.1.1795.2.24.2.7.61.3.6.1.4.1.1795.2.24.2.7.71.3.6.1.4.1.1795.2.24.2.7.81.3.6.1.4.1.1795.2.24.2.7.91.3.6.1.4.1.1795.2.24.2.7.10
- Namespace
- zhone
- Source file
PDN-CONFIG-MIB- Digest
sha256:0078d8f3f3daefbd56d01dd64ce4905e814deabc70f32505e6705e02913ac32a
Imports
| From | Symbols |
|---|---|
| IF-MIB | ifIndex |
| PDN-HEADER-MIB | pdn-devConfig |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Gauge32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, iso |
| SNMPv2-TC | DateAndTime, DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB IF-MIB PDN-CONFIG-MIB PDN-HEADER-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| devConfigArea OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.7.1 | |||
| devConfigAreaCopy OBJECT-TYPE This object is used to copy the entire contents of one configuration area into another configuration area. The supported number of factory configuration areas depends on the device model. The value read from this object is always noOp(1). | 1.3.6.1.4.1.1795.2.24.2.7.1.1 | INTEGER {noOp(1), active-to-customer1(2), active-to-customer2(3), customer1-to-active(4), customer1-to-customer2(5), customer2-to-active(6), customer2-to-customer1(7), factory1-to-active(8), factory1-to-customer1(9), factory1-to-customer2(10), factory2-to-active(11), factory2-to-customer1(12), factory2-to-customer2(13), factory3-to-active(14), factory3-to-customer1(15), factory3-to-customer2(16), factory4-to-active(17), factory4-to-customer1(18), factory4-to-customer2(19), factory5-to-active(20), factory5-to-customer1(21), factory5-to-customer2(22), factory6-to-active(23), factory6-to-customer1(24), factory6-to-customer2(25), factory7-to-active(26), factory7-to-customer1(27), factory7-to-customer2(28), factory8-to-active(29), factory8-to-customer1(30), factory8-to-customer2(31), factory9-to-active(32), factory9-to-customer1(33), factory9-to-customer2(34)} | read-write | mandatory |
| devConfigTestTimer OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.7.2 | |||
| devConfigTestTimeout OBJECT-TYPE This object specifies whether tests are to be terminated after a defined duration. If the value is enable(2), the duration is defined by devConfigTestDuration. | 1.3.6.1.4.1.1795.2.24.2.7.2.1 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| devConfigTestDuration OBJECT-TYPE This object specifies the duration that a test will be allowed to run before it is automatically terminated. Tests will only be terminated if devConfigTestTimeout is set to enable. | 1.3.6.1.4.1.1795.2.24.2.7.2.2 | INTEGER | read-write | mandatory |
| devConfigClockSrc OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.7.3 | |||
| devConfigClockSrcTable OBJECT-TYPE The clock source table. | 1.3.6.1.4.1.1795.2.24.2.7.3.1 | not-accessible | mandatory | |
| devConfigClockSrcEntry OBJECT-TYPE An entry in the clock source table. | 1.3.6.1.4.1.1795.2.24.2.7.3.1.1 | not-accessible | mandatory | |
| devCfgClkWhichSrc OBJECT-TYPE The clock source to which this entry is applicable. | 1.3.6.1.4.1.1795.2.24.2.7.3.1.1.1 | INTEGER {primary(1), secondary(2)} | read-only | mandatory |
| devCfgClkSource OBJECT-TYPE This object is used to select the source for the master clock for the device. The source selected provides synchronization for all the timing within the device, and the clocks for all of the external interfaces. If this object is interface(3), the specific interface used as the master clock source is specified using devCfgClkIfIndex. If this object is external(2), or external2(5), the clock rate can be specified using devCfgClkRate. | 1.3.6.1.4.1.1795.2.24.2.7.3.1.1.2 | INTEGER {internal(1), external(2), interface(3), dbm(4), external2(5)} | read-write | mandatory |
| devCfgClkIfIndex OBJECT-TYPE This object is used to select the interface to be used as the source for the master clock for the device, if devCfgClkSource is set to interface(3). The interface selected provides synchronization for all the timing within the device, and the clocks for all of the external interfaces. NOTE: if a synchronous data port is selected and the EDL is enabled for that synchronous data port, then the external device must provide a clock 8 Kbps less than the expected data port rate. For example, if the data port rate is set at 64 Kbps, the external clock source needs to supply a 56 Kbps clock signal. If devCfgClkSource is not interface(3), the value of this object is meaningless. | 1.3.6.1.4.1.1795.2.24.2.7.3.1.1.3 | INTEGER | read-write | mandatory |
| devCfgClkRate OBJECT-TYPE This object is used to specify the clock signal rate associated with the external source selected by the devCfgClkSource object. | 1.3.6.1.4.1.1795.2.24.2.7.3.1.1.4 | INTEGER {rate400Hz(1), rate8KHz(2), rate64KHz(3), rate1544KHz(4), rate2048KHz(5)} | read-write | mandatory |
| devConfigTrap OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.7.4 | |||
| devConfigTrapEnable OBJECT-TYPE Which trap types will be sent by the entity. This object is a bit map represented as a sum, therefore, multiple trap types can be enabled simultaneously. This objects sets flag (enable/disable) value on entity level. If trap enable/disable flags are set per interface level by some other object this object will read 'enabled' if any one of the interfaces is enabled. If any of the traps below are set to enabled by this object it will enable that trap on all interfaces on the entity. The various bit positions are: 1 warmStart traps 2 authenticationFailure traps 4 enterpriseSpecific traps 8 LinkUp trap 16 LinkDown Trap 32 path Trap 64 Latency Trap. | 1.3.6.1.4.1.1795.2.24.2.7.4.1 | INTEGER | read-write | mandatory |
| cCNTrapEnable OBJECT-TYPE This object is used to enable or disable configuration change trap. It is a bit sequence sum with only accepted values 1 or 2. Setting the bit sequence to 2 would mean enabling the trap and 1 would mean disabling it. | 1.3.6.1.4.1.1795.2.24.2.7.4.2 | INTEGER | read-write | mandatory |
| devConfigAlarm OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.7.5 | |||
| devConfigAlarmRelayCutoff OBJECT-TYPE Writing off(2) to this object will turn off the System Alarm Relay. Reading this object will always return noOp(1). | 1.3.6.1.4.1.1795.2.24.2.7.5.6 | INTEGER {noOp(1), off(2)} | read-write | mandatory |
| devConfigCardType OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.7.6 | |||
| devConfigCardTypeTable OBJECT-TYPE The Paradyne Card Type Table. | 1.3.6.1.4.1.1795.2.24.2.7.6.7 | not-accessible | mandatory | |
| devConfigCardTypeEntry OBJECT-TYPE An entry in the Paradyne Card Type Table. | 1.3.6.1.4.1.1795.2.24.2.7.6.7.1 | not-accessible | mandatory | |
| devCfgCardSlot OBJECT-TYPE The slot number which this card occupies in the chassis. | 1.3.6.1.4.1.1795.2.24.2.7.6.7.1.1 | INTEGER | read-only | mandatory |
| devCfgCardConfig OBJECT-TYPE The type of card which has been configured for this slot. | 1.3.6.1.4.1.1795.2.24.2.7.6.7.1.2 | INTEGER {emptySlot(1), unsupportedAPM(2), t1NAM(3), syncDataAPM(4), voiceFxsAPM(5), voiceEmAPM(6), voiceFxoAPM(7), dsxAPM(8), t1NoDsxNAM(9), misconfiguredAPM(10), ocu2APM(11), ocu6APM(12), dce6APM(13), sruAPM(14), ocu4APM(15), pktVoiceAPM(16), acceptingAPM(17), failedAPM(18), dpNAM(19), stNAM(20), ddsNAM(21), dualDsxNniNAM(22), t3NniNAM(23), t3NAM(24), dslNAM(25)} | read-only | mandatory |
| devCfgCardActual OBJECT-TYPE The type of card which is present in this slot. | 1.3.6.1.4.1.1795.2.24.2.7.6.7.1.3 | INTEGER {emptySlot(1), unsupportedAPM(2), t1NAM(3), syncDataAPM(4), voiceFxsAPM(5), voiceEmAPM(6), voiceFxoAPM(7), voiceDsxAPM(8), t1NoDsxNAM(9), misconfigured(10), ocu2APM(11), ocu6APM(12), dce6APM(13), sruAPM(14), ocu4APM(15), pktVoiceAPM(16), acceptingAPM(17), failedAPM(18), dpNAM(19), stNAM(20), ddsNAM(21), dualDsxNniNAM(22), t3NniNAM(23), t3NAM(24), dslNAM(25)} | read-only | mandatory |
| devCfgCardAction OBJECT-TYPE Writing accept(2) to this object changes the configured card type to match the type of card currently present in the slot. Reading this object always returns noOp(1). | 1.3.6.1.4.1.1795.2.24.2.7.6.7.1.4 | INTEGER {noOp(1), accept(2)} | read-write | mandatory |
| devConfigNetSync OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.7.7 | |||
| devConfigNetSyncRole OBJECT-TYPE Network Time Synchronization role item for a device in the network. none - Device will ignore network time synchronization messages. tributary - Update the network reference time each time the device receives an update massage. controller - The device will generate the synchronization message and Time of Day clock will be the same as the Network Reference Time. | 1.3.6.1.4.1.1795.2.24.2.7.7.1 | INTEGER {none(1), tributary(2), controller(3)} | read-write | mandatory |
| devConfigTime OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.7.8 | |||
| devConfigTimeOfDay OBJECT-TYPE This is standard definition of Device Time of Day (DateAndTime) SYNTAX. The only difference is that our group is defining timezone filed (8) optional. Display format-> 2d-1d-1d,1d:1d:1d.1d,1a1d:1d Fields description field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Timezone information (fileds 8-10) is optional. Note that if only local time is known, then timezone information (fields 8-10) is not present. | 1.3.6.1.4.1.1795.2.24.2.7.8.1 | DateAndTime | read-write | mandatory |
| devConfigChangeKeys OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.7.9 | |||
| devConfigChangeKeysTable OBJECT-TYPE The Paradyne Configuration Change Key Table. This table is in place to allow a Network Manager to know when the configuration on the device changes. Configuration can be found in several databases that may each have a unique access method. For this reason, the keys are in the form of a table. | 1.3.6.1.4.1.1795.2.24.2.7.9.1 | not-accessible | mandatory | |
| devConfigChangeKeysEntry OBJECT-TYPE An entry in the Paradyne Configuration Change Key Table. | 1.3.6.1.4.1.1795.2.24.2.7.9.1.1 | not-accessible | mandatory | |
| devConfigChangeKeysDbType OBJECT-TYPE The type of database that is being keyed. If a specific type is not supported by the device, noSuchName should be returned. | 1.3.6.1.4.1.1795.2.24.2.7.9.1.1.1 | INTEGER {generalConfig(1), rmonAlarm(2), rmonUserHistory(3), routerConfig(4)} | read-only | mandatory |
| devConfigChangeKeysDbKey OBJECT-TYPE A unique value that will change each time the database is altered. Effort should be made to increase the number of times the database can change without seeing the same key. | 1.3.6.1.4.1.1795.2.24.2.7.9.1.1.2 | Gauge | read-only | mandatory |
| devConfiguration OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.7.10 | |||
| devConfigComDiscTime OBJECT-TYPE This object is used to specify how long to wait before disconnecting. Inactivity is defined as no keyboard activity within a given period of time. The time is kept in seconds. The default is 300 seconds. | 1.3.6.1.4.1.1795.2.24.2.7.10.1 | INTEGER | read-write | mandatory |
| devConfigPortNumDisplayFormat OBJECT-TYPE This object is used to set display format for the port numbers. The default is unit/port number. sle(1) - this method is to use Single Logical Entity interface numbers. For example, if sle is confiugred the sle numbers range from 1 to 384 for a stack of 8 units with 48 ports each. unitport(2) - this method uses unitnumber/portnumber For previous example the numbers would be from 1/1 to 8/48. name(3) - This method allowes user to assign character strings (names) to each interface and to view the interfaces by names. | 1.3.6.1.4.1.1795.2.24.2.7.10.2 | INTEGER {sle(1), unitport(2), name(3)} | read-write | mandatory |
| devConfigDateDisplayFormat OBJECT-TYPE This object is used to specify which format will date be displayed in.The default is 'mmddyy' | 1.3.6.1.4.1.1795.2.24.2.7.10.3 | INTEGER {ddmmyy(1), mmddyy(2)} | read-write | mandatory |
| devAcceptRemoteResetFrame OBJECT-TYPE This object is used to enable/disable acceptance of remote reset frame which would result in hardware reset. The default setting is disabled. | 1.3.6.1.4.1.1795.2.24.2.7.10.4 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
Notifications
| Name | OID | Status |
|---|---|---|
| cCN NOTIFICATION-TYPE This trap signifies a Configuration change or software upgrade. This trap is of 'warning' class | 1.3.6.1.4.1.1795.2.24.2.7.4.0.7 |