PDN-ATMSTATS-MIB
- Registered at
- 1.3.6.1.4.1.1795.2.24.2.6.11.3
- Last updated
- 1900-02-28 12:00
- Organization
- Paradyne Networks MIB Working Group
- Revisions
- 1902-03-28 00:00, 1900-04-13 00:00, 1999-05-26 00:00
- Namespace
- zhone
- Source file
PDN-ATMSTATS-MIB- Digest
sha256:5259b22bd3d831a0856f1ad450890721d0ed00aee2b5f967409907cd3a172c7d
Description
This MIB Module supports ATM Statistics
Contact
Paradyne Networks 331 Newman Springs Road Red Bank, NJ 07701 www.paradyne.com General Comments to: mibwg_team@eng.paradyne.com
Imports
| From | Symbols |
|---|---|
| ATM-MIB | atmVclVci, atmVclVpi |
| IF-MIB | ifIndex |
| PDN-HEADER-MIB | pdnAtm |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, RowStatus, TEXTUAL-CONVENTION, TimeInterval |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
ATM-MIB ATM-TC-MIB IANAifType-MIB IF-MIB PDN-ATMSTATS-MIB PDN-HEADER-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| pdnAtmVplStat OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.6.11.3.1 | |||
| pdnAtmVplStatTable OBJECT-TYPE This table contains all statistic counters per VPL. It is used to monitor the usage of the VPL in terms of incoming cells and outgoing cells. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.1.1 | not-accessible | current | |
| pdnAtmVplStatEntry OBJECT-TYPE Each entry in this table represents a VPL. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.1.1.1 | not-accessible | current | |
| pdnAtmVplStatIfIndex OBJECT-TYPE A unique value for each interface. Its value ranges between 1 and the value of ifNumber. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.1.1.1.1 | Integer32 | read-only | current |
| pdnAtmVplStatVpi OBJECT-TYPE The VPI value of the VPL. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.1.1.1.2 | Integer32 | read-only | current |
| pdnAtmVplStatTotalCellIns OBJECT-TYPE The total number of valid ATM cells received by this VPL including both CLP=0 and CLP=1 cells. The cells are counted prior to the application of the traffic policing. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.1.1.1.3 | Counter32 | read-only | current |
| pdnAtmVplStatClp0CellIns OBJECT-TYPE The number of valid ATM cells received by this VPL with CLP=0. The cells are counted prior to the application of the traffic policing. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.1.1.1.4 | Counter32 | read-only | current |
| pdnAtmVplStatTotalDiscards OBJECT-TYPE The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.1.1.1.5 | Counter32 | read-only | current |
| pdnAtmVplStatClp0Discards OBJECT-TYPE The total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.1.1.1.6 | Counter32 | read-only | current |
| pdnAtmVplStatTotalCellOuts OBJECT-TYPE The total number of valid ATM cells transmitted by this VPL. This includes both CLP=0 and CLP=1 cells. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.1.1.1.7 | Counter32 | read-only | current |
| pdnAtmVplStatClp0CellOuts OBJECT-TYPE The total number of valid ATM cells transmitted with CLP=0 by this VPL. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.1.1.1.8 | Counter32 | read-only | current |
| pdnAtmVplStatTaggedOuts OBJECT-TYPE The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VPL. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.1.1.1.9 | Counter32 | read-only | current |
| pdnAtmVclStat OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2 | |||
| pdnAtmVclStatTable OBJECT-TYPE This table contains all statistic counters per VCL. It is used to monitor the usage of the VCL in terms of incoming cells and outgoing cells. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.2 | not-accessible | current | |
| pdnAtmVclStatEntry OBJECT-TYPE Each entry in this table represents a VCL. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.2.1 | not-accessible | current | |
| pdnAtmVclStatIfIndex OBJECT-TYPE A unique value for each interface. Its value ranges between 1 and the value of ifNumber. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.2.1.1 | Integer32 | read-only | current |
| pdnAtmVclStatVpi OBJECT-TYPE The VPI value of the VCL. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.2.1.2 | Integer32 | read-only | current |
| pdnAtmVclStatVci OBJECT-TYPE The VCI value of the VCL. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.2.1.3 | Integer32 | read-only | current |
| pdnAtmVclStatTotalCellIns OBJECT-TYPE The total number of valid ATM cells received by this VCL including both CLP=0 and CLP=1 cells. The cells are counted prior to the application of the traffic policing. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.2.1.4 | Counter32 | read-only | current |
| pdnAtmVclStatClp0CellIns OBJECT-TYPE The number of valid ATM cells received by this VCL with CLP=0. The cells are counted prior to the application of the traffic policing. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.2.1.5 | Counter32 | read-only | current |
| pdnAtmVclStatTotalDiscards OBJECT-TYPE The total number of valid ATM cells discarded by the traffic policing entity. This includes cells originally received with CLP=0 and CLP=1. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.2.1.6 | Counter32 | read-only | current |
| pdnAtmVclStatClp0Discards OBJECT-TYPE The total number of valid ATM cells received with CLP=0 an discarded by the traffic policing entity. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.2.1.7 | Counter32 | read-only | current |
| pdnAtmVclStatTotalCellOuts OBJECT-TYPE The total number of valid ATM cells transmitted by this VCL. This includes both CLP=0 and CLP=1 cells. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.2.1.8 | Counter32 | read-only | current |
| pdnAtmVclStatClp0CellOuts OBJECT-TYPE The total number of valid ATM cells transmitted with CLP=0 by this VCL. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.2.1.9 | Counter32 | read-only | current |
| pdnAtmVclStatTaggedOuts OBJECT-TYPE The total number of valid ATM cells tagged by the traffic policing entity from CLP=0 to CLP=1 and transmitted by this VCL. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.2.1.10 | Counter32 | read-only | current |
| pdnAtmVclStatRowStatus OBJECT-TYPE This object is used to create a new row or delete an existing row in this table. When a new row is added, statistics are collected for the VCL. Statistics collection is terminated by deletion of the row. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.2.1.11 | RowStatus | read-write | current |
| pdnAtmVclCurrTable OBJECT-TYPE This table maintains per-TP statistics for the fifteen-minute interval currently being collected. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.3 | not-accessible | current | |
| pdnAtmVclCurrEntry OBJECT-TYPE An entry in this table for VCL termination points. Each VCL Termination Point automatically has an entry in this table associated with it. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.3.1 | not-accessible | current | |
| pdnAtmVclCurrElapsedTime OBJECT-TYPE Amount of time, measured in seconds, that statistics for this entry (the current interval) have been counted. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.3.1.1 | TimeInterval | read-only | current |
| pdnAtmVclCurrTotalCellIns OBJECT-TYPE The total number of valid ATM cells received by this VCL. This number corresponds to that of toal cells recieved from CPE if this interface is a DSL ATM interface | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.3.1.2 | Gauge32 | read-only | current |
| pdnAtmVclCurrTotalInDiscards OBJECT-TYPE The number of discarded received cells. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.3.1.3 | Gauge32 | read-only | current |
| pdnAtmVclCurrTotalCellOuts OBJECT-TYPE The number of cells that have been successfully sent. This number corresponds to that of toal cells transmitted to CPE if this interface is a DSL ATM interface | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.3.1.4 | Gauge32 | read-only | current |
| pdnAtmVclCurrTotalOutDiscards OBJECT-TYPE The number of discarded transmitted cells since this interval. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.3.1.5 | Gauge32 | read-only | current |
| pdnAtmVclHistTable OBJECT-TYPE This table maintains per-interface statistics for previous fifteen-minute intervals. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.4 | not-accessible | current | |
| pdnAtmVclHistEntry OBJECT-TYPE An entry in History Data table for VCL termination points. Each VCL Termination Point automatically has an entry in this table associated with it. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.4.1 | not-accessible | current | |
| pdnAtmVclHistIndex OBJECT-TYPE A number between 1 and 96, which identifies the interval for which the set of statistics in this entry was collected. The interval identified by 1 is the most recently completed 15 minute interval, and the interval identified by N is the interval immediately preceding the one identified by N-1. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.4.1.1 | Integer32 (1..96) | not-accessible | current |
| pdnAtmVclHistElapsedTime OBJECT-TYPE Amount of Time, measured in units of 0.01 second, that statistics for this entry(the current interval) have been counted. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.4.1.2 | TimeInterval | read-only | current |
| pdnAtmVclHistTotalCellIns OBJECT-TYPE The total number of valid ATM cells received by this VCL during this interval. This number corresponds to that of toal cells recieved from CPE if this interface is a DSL ATM interface | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.4.1.3 | Gauge32 | read-only | current |
| pdnAtmVclHistTotalInDiscards OBJECT-TYPE The number of discarded received cells during this interval. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.4.1.4 | Gauge32 | read-only | current |
| pdnAtmVclHistTotalCellOuts OBJECT-TYPE The number of cells that have been successfully sent during this interval. This number corresponds to that of toal cells transmitted to CPE if this interface is a DSL ATM interface | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.4.1.5 | Gauge32 | read-only | current |
| pdnAtmVclHistTotalOutDiscards OBJECT-TYPE The number of discarded transmitted cells during this interval. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.2.4.1.6 | Gauge32 | read-only | current |
| pdnAtmStat OBJECT-IDENTITY | 1.3.6.1.4.1.1795.2.24.2.6.11.3.3 | |||
| pdnAtmStatTable OBJECT-TYPE This table contains all statistic counters per interface. It is used to monitor the errors in terms of incoming cells. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.3.1 | not-accessible | current | |
| pdnAtmStatEntry OBJECT-TYPE Each entry in this table represents a error count per interface. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.3.1.1 | not-accessible | current | |
| pdnAtmStatHECErrors OBJECT-TYPE The total number of ATM cells discarded on this interface due to a HEC violation. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.3.1.1.1 | Counter32 | read-only | current |
| pdnAtmStatLCDErrors OBJECT-TYPE The total number of Loss of Cell Delineataion events (LCD) that occured on this interface. | 1.3.6.1.4.1.1795.2.24.2.6.11.3.3.1.1.2 | Counter32 | read-only | current |