PANDUIT-MIB
- Registered at
- 1.3.6.1.4.1.19536
- Last updated
- 2023-07-24 12:00
- Organization
- Panduit
- Revisions
- 2023-07-24 12:00, 2023-06-27 12:00, 2023-03-13 12:00, 2023-02-13 12:00, 2022-12-15 12:00, 2022-10-17 12:00, 2022-07-12 12:00, 2022-02-04 12:00, 2021-02-02 12:00, 2020-06-30 12:00, 2020-03-30 12:00, 2019-02-12 12:00, 2018-01-12 12:00
- Namespace
- panduit
- Source file
PANDUIT-MIB- Digest
sha256:25f5a34a3c51496b5b854e3bdc1c68fb1d2facd59985dcd4b5e6a19dfe01647b
Description
SmartZone G5 iPDU
Contact
Panduit Postal: Panduit 18900 Panduit Drive Tinley Park, IL 60487 USA Tel: +1 708 532-1800/888-506-5400 E-mail: systemsupport@panduit.com
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-MIB | sysDescr |
| SNMPv2-SMI | Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
PANDUIT-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| panduit OBJECT-IDENTITY | 1.3.6.1.4.1.19536 | |||
| pdug5 OBJECT-IDENTITY | 1.3.6.1.4.1.19536.10.1 | |||
| pdug5Ident OBJECT-IDENTITY | 1.3.6.1.4.1.19536.10.1.1 | |||
| pdug5NumberPDU OBJECT-TYPE The number of PDUs detected (in its daisy chain). | 1.3.6.1.4.1.19536.10.1.1.1 | Integer32 (1..4) | read-only | current |
| pdug5IdentTable OBJECT-TYPE Aggregate Object with number of entries equal to pdug5NumberPDU . | 1.3.6.1.4.1.19536.10.1.1.2 | not-accessible | current | |
| pdug5IdentEntry OBJECT-TYPE The Identity table entry containing the name, model, manufacturer, firmware version, part number, etc. | 1.3.6.1.4.1.19536.10.1.1.2.1 | not-accessible | current | |
| pdug5IdentIndex OBJECT-TYPE Index for the pdug5IdentEntry table. | 1.3.6.1.4.1.19536.10.1.1.2.1.1 | Integer32 (1..6) | not-accessible | current |
| pdug5Name OBJECT-TYPE The string identify the device in daisy chain. Example PDU A. | 1.3.6.1.4.1.19536.10.1.1.2.1.2 | DisplayString (SIZE(0..63)) | read-write | current |
| pdug5Model OBJECT-TYPE The Device Model. | 1.3.6.1.4.1.19536.10.1.1.2.1.3 | DisplayString (SIZE(0..63)) | read-only | current |
| pdug5Manufacturer OBJECT-TYPE The Device Manufacturer Name. | 1.3.6.1.4.1.19536.10.1.1.2.1.4 | DisplayString (SIZE(0..63)) | read-only | current |
| pdug5FirmwareVersion OBJECT-TYPE The firmware revision level of the device. | 1.3.6.1.4.1.19536.10.1.1.2.1.5 | DisplayString (SIZE(0..63)) | read-only | current |
| pdug5FirmwareVersionTimeStamp OBJECT-TYPE Timestamp of when the PDU firmware was last updated | 1.3.6.1.4.1.19536.10.1.1.2.1.6 | DisplayString | read-only | current |
| pdug5PartNumber OBJECT-TYPE The device part number. Example P36E09M. | 1.3.6.1.4.1.19536.10.1.1.2.1.7 | DisplayString (SIZE(0..63)) | read-only | current |
| pdug5SerialNumber OBJECT-TYPE The device serial number, 10-digit. | 1.3.6.1.4.1.19536.10.1.1.2.1.8 | DisplayString (SIZE(0..63)) | read-only | current |
| pdug5Status OBJECT-TYPE The overall status of the device. A value of OK(2) indicates the device is operating normally. A value of degraded(3) indicates the device is operating with warning indicators. A value of failed(4) indicates the device is operating with critical indicators. | 1.3.6.1.4.1.19536.10.1.1.2.1.9 | INTEGER {other(1), ok(2), degraded(3), failed(4)} | read-only | current |
| pdug5Controllable OBJECT-TYPE This object indicates whether or not the device is controllable. | 1.3.6.1.4.1.19536.10.1.1.2.1.10 | INTEGER {yes(1), no(2)} | read-only | current |
| pdug5InputPhaseCount OBJECT-TYPE The number of input phase on this pdu 1 or 3. | 1.3.6.1.4.1.19536.10.1.1.2.1.11 | Integer32 (1..3) | read-only | current |
| pdug5GroupCount OBJECT-TYPE The number of groups (breakers) on this pdu. | 1.3.6.1.4.1.19536.10.1.1.2.1.12 | Integer32 (0..12) | read-only | current |
| pdug5OutletCount OBJECT-TYPE The number of outlets in this PDU. | 1.3.6.1.4.1.19536.10.1.1.2.1.13 | Integer32 (1..48) | read-only | current |
| pdug5MACAddress OBJECT-TYPE The assigned MAC address for this PDU. | 1.3.6.1.4.1.19536.10.1.1.2.1.14 | DisplayString | read-only | current |
| pdug5IPv4Address OBJECT-TYPE The current IPv4 Address. A value of 0.0.0.0 indicates an error or an unset option. | 1.3.6.1.4.1.19536.10.1.1.2.1.15 | IpAddress | read-only | current |
| pdug5IPv6Address OBJECT-TYPE The current IPv6 Address. A value of 0.0.0.0.0.0 indicates an error or an unset option. | 1.3.6.1.4.1.19536.10.1.1.2.1.16 | DisplayString | read-only | current |
| pdug5HWVersion OBJECT-TYPE The current Hardware Version. 1.0 - G5 (STM) No Powershare, 1.5 - G5 (STM) with Powershare, 2.0 - G6 Processor | 1.3.6.1.4.1.19536.10.1.1.2.1.17 | DisplayString | read-only | current |
| pdug5ConfigTable OBJECT-TYPE Aggregate Object with number of entries equal to pdug5NumberPDU. | 1.3.6.1.4.1.19536.10.1.1.3 | not-accessible | current | |
| pdug5ConfigEntry OBJECT-TYPE Read Configuration data from the PDU being queried. | 1.3.6.1.4.1.19536.10.1.1.3.1 | not-accessible | current | |
| pdug5ConfigIndex OBJECT-TYPE The index of PDU configuration entry. | 1.3.6.1.4.1.19536.10.1.1.3.1.1 | Integer32 (1..4) | not-accessible | current |
| pdug5ConfigSsh OBJECT-TYPE Setting this OID to off(0) will disable the SSH connection. Setting this OID to on(1) will enable the SSH connection. iNC reboot will be required for the settings to take effect. | 1.3.6.1.4.1.19536.10.1.1.3.1.2 | INTEGER {off(0), on(1)} | read-write | current |
| pdug5ConfigFtps OBJECT-TYPE Setting this OID to off(0) will disable the FTPS connection. Setting this OID to on(1) will enable the FTPS connection. iNC reboot will be required for the settings to take effect | 1.3.6.1.4.1.19536.10.1.1.3.1.3 | INTEGER {off(0), on(1)} | read-write | current |
| pdug5ConfigHttp OBJECT-TYPE Setting this OID to off(0) will disable the HTTP connection. Setting this OID to on(1) will enable the HTTP connection.iNC reboot will be required for the settings to take effect | 1.3.6.1.4.1.19536.10.1.1.3.1.4 | INTEGER {off(0), on(1)} | read-write | current |
| pdug5ConfigHttps OBJECT-TYPE Setting this OID to off(0) will disable the HTTPS connection. Setting this OID to on(1) will enable the HTTPS connection.iNC reboot will be required for the settings to take effect | 1.3.6.1.4.1.19536.10.1.1.3.1.5 | INTEGER {off(0), on(1)} | read-write | current |
| pdug5ConfigIPv4IPv6Switch OBJECT-TYPE Setting this OID to IPv4(1) will enable the IPv4 configuration. Setting this OID to IPv6(2) will enable the IPv6 configuration. Setting this OID to IPv4&IPv6(3) will enable both IPv4 and IPv6 configuration.iNC reboot will be required for the settings to take effect | 1.3.6.1.4.1.19536.10.1.1.3.1.6 | INTEGER {iPv4(1), iPv6(2), iPv4IPv6(3)} | read-write | current |
| pdug5ConfigRedfishAPI OBJECT-TYPE Setting this OID to off(0) will disable the Redfish API. Setting this OID to on(1) will enable the Redfish API.iNC reboot will be required for the settings to take effect | 1.3.6.1.4.1.19536.10.1.1.3.1.7 | INTEGER {off(0), on(1)} | read-write | current |
| pdug5ConfigOledDispalyOrientation OBJECT-TYPE Indicates the intended physical orientation of OLED display. displayNormal(1) indicates normal orientation. displayReverse(2) indicates upside down orientation. | 1.3.6.1.4.1.19536.10.1.1.3.1.8 | INTEGER {displayNormal(1), displayReverse(2)} | read-write | current |
| pdug5ConfigEnergyReset OBJECT-TYPE Setting this OID to reset(2) will cause the device energy meter value to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not supported this feature will respond to this OID with a value of notSupported(3). Attempts to set this OID in these models will fail. | 1.3.6.1.4.1.19536.10.1.1.3.1.9 | INTEGER {noOperation(1), reset(2), notSupported(3)} | read-write | current |
| pdug5ConfigNetworkManagementCardReset OBJECT-TYPE Getting this OID will return noOperation(0). Getting this OID to reset(1) will reset iNC. | 1.3.6.1.4.1.19536.10.1.1.3.1.10 | INTEGER {noOperation(0), reset(1)} | read-write | current |
| pdug5ConfigDaisyChainStatus OBJECT-TYPE Setting this OID will change daisychain mode. 0:QNA,1:DNA. | 1.3.6.1.4.1.19536.10.1.1.3.1.11 | INTEGER {daisychain(0), rna(1)} | read-write | current |
| pdug5PowershareTable OBJECT-TYPE Aggregate Object with number of entries equal to number of PDUs and Power share | 1.3.6.1.4.1.19536.10.1.1.4 | not-accessible | current | |
| pdug5PowershareEntry OBJECT-TYPE The Power share entry containing the available, input, output etc. | 1.3.6.1.4.1.19536.10.1.1.4.1 | not-accessible | current | |
| pdug5PowershareIndex OBJECT-TYPE The index of the PDU Power share table entry | 1.3.6.1.4.1.19536.10.1.1.4.1.1 | Integer32 (1..4) | not-accessible | current |
| pdug5PowershareFunctionStatus OBJECT-TYPE Power share function status on PDU. | 1.3.6.1.4.1.19536.10.1.1.4.1.2 | INTEGER {notAvailable(0), available(1)} | read-only | current |
| pdug5PowershareFunctionUpstreamStatus OBJECT-TYPE Power share function status on upstream PDU | 1.3.6.1.4.1.19536.10.1.1.4.1.3 | INTEGER {notAvailable(0), available(1)} | read-only | current |
| pdug5PowershareOutput OBJECT-TYPE Power share output status. | 1.3.6.1.4.1.19536.10.1.1.4.1.4 | INTEGER {off(0), on(1)} | read-only | current |
| pdug5PowershareInput OBJECT-TYPE Power share input status. | 1.3.6.1.4.1.19536.10.1.1.4.1.5 | INTEGER {off(0), on(1)} | read-only | current |
| pdug5PowershareOptMode OBJECT-TYPE Power share operation status of PDU. 0 meaning pdu is using powershare to power the NMC, 1 meaning pdu is using mains power to power the NMC | 1.3.6.1.4.1.19536.10.1.1.4.1.6 | INTEGER {powerByPowershare(0), powerByMains(1)} | read-only | current |
| pdug5PowershareFunc OBJECT-TYPE Enable/Disable Powershare function of PDU. Set 1 to enable powershare. Set 0 to disable powershare | 1.3.6.1.4.1.19536.10.1.1.4.1.7 | INTEGER {disablePowershare(0), enablePowershare(1)} | read-write | current |
| pdug5Input OBJECT-IDENTITY | 1.3.6.1.4.1.19536.10.1.2 | |||
| pdug5InputTable OBJECT-TYPE Aggregate Object with number of entries equal to pdug5NumberPDU . | 1.3.6.1.4.1.19536.10.1.2.1 | not-accessible | current | |
| pdug5InputEntry OBJECT-TYPE The ident table entry containing the VA, Watts, WH, etc. | 1.3.6.1.4.1.19536.10.1.2.1.1 | not-accessible | current | |
| pdug5InputType OBJECT-TYPE Type of input - single phase, split phase, three phase delta, or three phase wye. | 1.3.6.1.4.1.19536.10.1.2.1.1.1 | INTEGER {singlePhase(1), splitPhase(2), threePhaseDelta(3), threePhaseWye(4)} | read-only | current |
| pdug5InputFrequency OBJECT-TYPE The measured input frequency from the PDU meters in tenths of Hz. | 1.3.6.1.4.1.19536.10.1.2.1.1.2 | Integer32 (0..2147483647) | read-only | current |
| pdug5InputFrequencyStatus OBJECT-TYPE Status of the measured input frequency relative to the nominal frequency and the admitted tolerance. | 1.3.6.1.4.1.19536.10.1.2.1.1.3 | INTEGER {good(1), outOfRange(2)} | read-only | current |
| pdug5InputPowerVA OBJECT-TYPE A total input VA of all phases. Units are VA. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.1.1.4 | Integer32 | read-only | current |
| pdug5InputPowerWatts OBJECT-TYPE A total input Watts of all phases. Units are Watts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.1.1.5 | Integer32 | read-only | current |
| pdug5InputTotalEnergy OBJECT-TYPE A total input Watt-Hour value for all phases. Units are KWh. This value is accumulated since PDU in service. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.1.1.6 | Integer32 | read-only | current |
| pdug5InputPowerWattHourTimer OBJECT-TYPE A Timestamp of when the Total Input WH was last reset. | 1.3.6.1.4.1.19536.10.1.2.1.1.7 | DisplayString (SIZE(0..22)) | read-only | current |
| pdug5InputResettableEnergy OBJECT-TYPE A total input Watt-Hour value for all phases. Units are Wh. This value can be reset to 0 using GUI. In that case, the pdug5InputPowerWattHourTimer will be reset as well A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.1.1.8 | Integer32 | read-only | current |
| pdug5InputPowerFactor OBJECT-TYPE An input PF value. Units are in hundredths, for example a power factor of 0.95 would be returned as 95, and 0.92 would be returned as 92. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.1.1.9 | Integer32 | read-only | current |
| pdug5InputPowerVAR OBJECT-TYPE An input VAR value. Units are VAR. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.1.1.10 | Integer32 | read-only | current |
| pdug5InputTotalCurrent OBJECT-TYPE All phases total current value. Units are 0.01 amps. For 3 phase, mathematically add totally 3 phase current together. | 1.3.6.1.4.1.19536.10.1.2.1.1.11 | Integer32 | read-only | current |
| pdug5InputPhaseTable OBJECT-TYPE Aggregate Object with number of entries equal to number of PDUs (pdug5NumberPDU) and number of input phase (pdug5InputPhaseCount). | 1.3.6.1.4.1.19536.10.1.2.2 | not-accessible | current | |
| pdug5InputPhaseEntry OBJECT-TYPE The input table entry containing the voltage, current, frequency, power for each phase. Entries are given with number of pdu and number of input phase 1, 2, or 3. | 1.3.6.1.4.1.19536.10.1.2.2.1 | not-accessible | current | |
| pdug5InputPhaseIndex OBJECT-TYPE Index for the pdug5InputEntry table. | 1.3.6.1.4.1.19536.10.1.2.2.1.1 | Integer32 (1..3) | not-accessible | current |
| pdug5InputPhaseVoltageMeasType OBJECT-TYPE Value indicates what input voltage is being measured in this table row - single phase voltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2, phase 2 to phase 3, or phase 3 to phase 1. | 1.3.6.1.4.1.19536.10.1.2.2.1.2 | INTEGER {singlePhase(1), phase1toN(2), phase2toN(3), phase3toN(4), phase1to2(5), phase2to3(6), phase3to1(7)} | read-only | current |
| pdug5InputPhaseVoltage OBJECT-TYPE An input voltage measurement value. Values is in 0.1 V. | 1.3.6.1.4.1.19536.10.1.2.2.1.3 | Integer32 | read-only | current |
| pdug5InputPhaseVoltageThStatus OBJECT-TYPE Status of the measured input voltage relative to the configured thresholds. | 1.3.6.1.4.1.19536.10.1.2.2.1.4 | INTEGER {good(1), lowWarning(2), lowCritical(3), highWarning(4), highCritical(5)} | read-only | current |
| pdug5InputPhaseVoltageThLowerWarning OBJECT-TYPE Lower warning threshold. Units are 0.1 volts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.5 | Integer32 (-1..500000) | read-write | current |
| pdug5InputPhaseVoltageThLowerCritical OBJECT-TYPE Lower critical threshold. Units are 0.1 volts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.6 | Integer32 (-1..500000) | read-write | current |
| pdug5InputPhaseVoltageThUpperWarning OBJECT-TYPE Upper warning threshold. Units are 0.1 volts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.7 | Integer32 (-1..500000) | read-write | current |
| pdug5InputPhaseVoltageThUpperCritical OBJECT-TYPE Upper critical threshold. Units are 0.1 volts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.8 | Integer32 (-1..500000) | read-write | current |
| pdug5InputPhaseCurrentMeasType OBJECT-TYPE Which input wire is being measured in this table row - single phase, neutral, phase 1, phase 2, or phase 3. | 1.3.6.1.4.1.19536.10.1.2.2.1.9 | INTEGER {singlePhase(1), neutral(2), phase1(3), phase2(4), phase3(5)} | read-only | current |
| pdug5InputPhaseCurrentRating OBJECT-TYPE Rated current capacity of the input. A negative value indicates that the hardware current capacity is unknown. Units are 0.01 amps. | 1.3.6.1.4.1.19536.10.1.2.2.1.10 | Integer32 | read-only | current |
| pdug5InputPhaseCurrent OBJECT-TYPE An input current measurement value. Units are 0.01 amps. | 1.3.6.1.4.1.19536.10.1.2.2.1.11 | Integer32 | read-only | current |
| pdug5InputPhaseCurrentThStatus OBJECT-TYPE Status of the measured input current relative to the configured thresholds. | 1.3.6.1.4.1.19536.10.1.2.2.1.12 | INTEGER {good(1), lowWarning(2), lowCritical(3), highWarning(4), highCritical(5)} | read-only | current |
| pdug5InputPhaseCurrentThLowerWarning OBJECT-TYPE Lower warning threshold. Units are 0.01 amps. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.13 | Integer32 (-1..100000) | read-write | current |
| pdug5InputPhaseCurrentThLowerCritical OBJECT-TYPE Lower critical threshold. Units are 0.01 amps. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.14 | Integer32 (-1..100000) | read-write | current |
| pdug5InputPhaseCurrentThUpperWarning OBJECT-TYPE Upper warning threshold. Units are 0.01 amps. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.15 | Integer32 (-1..100000) | read-write | current |
| pdug5InputPhaseCurrentThUpperCritical OBJECT-TYPE Upper critical threshold. Units are 0.01 amps. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.16 | Integer32 (-1..100000) | read-write | current |
| pdug5InputPhaseCurrentPercentLoad OBJECT-TYPE Current percent load, based on the rated current capacity. Units are percentage, for example 80% will be returned as 80. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.17 | Integer32 | read-only | current |
| pdug5InputPhasePowerMeasType OBJECT-TYPE Which input wire is being measured in this table row - single phase, neutral, phase 1, phase 2, or phase 3. | 1.3.6.1.4.1.19536.10.1.2.2.1.18 | INTEGER {singlePhase(1), neutral(2), phase1(3), phase2(4), phase3(5)} | read-only | current |
| pdug5InputPhasePowerVA OBJECT-TYPE An input VA value. Units are VA. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.19 | Integer32 | read-only | current |
| pdug5InputPhasePowerWatts OBJECT-TYPE An input Watts value. Units are Watts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.20 | Integer32 | read-only | current |
| pdug5InputPhasePowerWattHour OBJECT-TYPE A Watt-Hour value for each Input phase. Units are WH. This value can be reset to 0 using GUI. In that case, the pdug5InputPhasePowerWattHourTimer will be reset as well A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.21 | Integer32 | read-only | current |
| pdug5InputPhasePowerWattHourTimer OBJECT-TYPE Timestamp of when input Watt-hours (inputWh) was last reset. | 1.3.6.1.4.1.19536.10.1.2.2.1.22 | DisplayString (SIZE(0..22)) | read-only | current |
| pdug5InputPhasePowerFactor OBJECT-TYPE An input PF value. Units are in hundredths, for example a power factor of 0.95 would be returned as 95, and 0.92 would be returned as 92. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.23 | Integer32 | read-only | current |
| pdug5InputPhasePowerVAR OBJECT-TYPE An input VAR value. Units are VAR. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.24 | Integer32 | read-only | current |
| pdug5InputPhaseVoltageThResetThld OBJECT-TYPE The Reset threshold is the number of volts the reading needs to fall below the threshold setting for the condition to be cleared. Units are 0.1 volts. | 1.3.6.1.4.1.19536.10.1.2.2.1.25 | Integer32 | read-write | current |
| pdug5InputPhaseVoltageThChangeDelay OBJECT-TYPE The number of consecutive sample that the condition is present before an alarm is raised. | 1.3.6.1.4.1.19536.10.1.2.2.1.26 | Integer32 (0..100) | read-write | current |
| pdug5InputPhaseVoltageThCtrl OBJECT-TYPE Input phase voltage alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable | 1.3.6.1.4.1.19536.10.1.2.2.1.27 | Integer32 | read-write | current |
| pdug5InputPhaseCurrentThResetThld OBJECT-TYPE The Reset threshold is the number of amps the reading needs to fall below the threshold setting for the condition to be cleared. Units are 0.01 amps. | 1.3.6.1.4.1.19536.10.1.2.2.1.28 | Integer32 | read-write | current |
| pdug5InputPhaseCurrentThChangeDelay OBJECT-TYPE The number of consecutive sample that the condition is present before an alarm is raised. | 1.3.6.1.4.1.19536.10.1.2.2.1.29 | Integer32 (0..100) | read-write | current |
| pdug5InputPhaseCurrentThCtrl OBJECT-TYPE Input phase current alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable | 1.3.6.1.4.1.19536.10.1.2.2.1.30 | Integer32 | read-write | current |
| pdug5InputPowerThresholdThLowerWarning OBJECT-TYPE Lower warning Power threshold. Units are in Watts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.31 | Integer32 (-1..500000) | read-write | current |
| pdug5InputPowerThresholdThLowerCritical OBJECT-TYPE Lower critical Power threshold. Units are in Watts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.32 | Integer32 (-1..500000) | read-write | current |
| pdug5InputPowerThresholdThUpperWarning OBJECT-TYPE Upper warning Power threshold. Units are in Watts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.33 | Integer32 (-1..500000) | read-write | current |
| pdug5InputPowerThresholdThUpperCritical OBJECT-TYPE Upper critical Power threshold. Units are in Watts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.34 | Integer32 (-1..500000) | read-write | current |
| pdug5InputPowerThresholdThResetThld OBJECT-TYPE The Reset threshold is the number of watts the reading needs to fall below the threshold setting for the condition to be cleared. Units are watts. | 1.3.6.1.4.1.19536.10.1.2.2.1.35 | Integer32 | read-write | current |
| pdug5InputPowerThresholdThChangeDelay OBJECT-TYPE The number of consecutive sample that the condition is present before an alarm is raised. | 1.3.6.1.4.1.19536.10.1.2.2.1.36 | Integer32 (0..100) | read-write | current |
| pdug5InputPowerThresholdThCtrl OBJECT-TYPE Power alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable | 1.3.6.1.4.1.19536.10.1.2.2.1.37 | Integer32 | read-write | current |
| pdug5InputEnergyThresholdThUpperWarning OBJECT-TYPE Upper warning Energy threshold. Units are in Watts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.38 | Integer32 (-1..500000) | read-write | current |
| pdug5InputEnergyThresholdThUpperCritical OBJECT-TYPE Upper critical Energy threshold. Units are in Watts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.2.1.39 | Integer32 (-1..500000) | read-write | current |
| pdug5InputEnergyThresholdThResetThld OBJECT-TYPE The Reset threshold is the number of watts the reading needs to fall below the threshold setting for the condition to be cleared. Units are watts. | 1.3.6.1.4.1.19536.10.1.2.2.1.40 | Integer32 | read-write | current |
| pdug5InputEnergyThresholdThChangeDelay OBJECT-TYPE The number of consecutive sample that the condition is present before an alarm is raised. | 1.3.6.1.4.1.19536.10.1.2.2.1.41 | Integer32 (0..100) | read-write | current |
| pdug5InputEnergyThresholdThCtrl OBJECT-TYPE Energy alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable | 1.3.6.1.4.1.19536.10.1.2.2.1.42 | Integer32 | read-write | current |
| pdug5InputPhasePowerThStatus OBJECT-TYPE Status of the measured input current relative to the configured thresholds. | 1.3.6.1.4.1.19536.10.1.2.2.1.43 | INTEGER {good(1), lowWarning(2), lowCritical(3), highWarning(4), highCritical(5)} | read-only | current |
| pdug5InputRcmTable OBJECT-TYPE Aggregate Object with number of entries equal to number of PDUs (pdug5NumberPDU) and number of RCM modules per PDU. | 1.3.6.1.4.1.19536.10.1.2.3 | not-accessible | current | |
| pdug5InputRcmEntry OBJECT-TYPE The ident table entry containing the RCM Module status, RCM current, RCM module threshold settings, etc. | 1.3.6.1.4.1.19536.10.1.2.3.1 | not-accessible | current | |
| pdug5InputRcmEnabled OBJECT-TYPE RCM configuration value off(0) if the PDU doesn't have RCM, on(1) if the PDU has RCM. | 1.3.6.1.4.1.19536.10.1.2.3.1.1 | INTEGER {featureNotAvailable(-1), off(0), on(1)} | read-only | current |
| pdug5InputRcmModStatus OBJECT-TYPE RCM module status ok(2) if the PDU can communicate with the RCM module, failed(4) if the PDU cannot communicate with the RCM module, degraded(3) if the PDU can communicate with the RCM module and the last self-test failed. | 1.3.6.1.4.1.19536.10.1.2.3.1.2 | INTEGER {featureNotAvailable(-1), ok(2), degraded(3), failed(4)} | read-only | current |
| pdug5InputRcmThUpperWarning OBJECT-TYPE RCM Current Upper warning threshold. Units are 0.01 amps. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.3.1.3 | Integer32 (15..300) | read-write | current |
| pdug5InputRcmThUpperCritical OBJECT-TYPE RCM Current Upper critical threshold. Units are 0.01 amps. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.2.3.1.4 | Integer32 (15..300) | read-write | current |
| pdug5InputRcmThResetThld OBJECT-TYPE The Reset threshold is the number of amps the reading needs to fall below the threshold setting for the condition to be cleared. Units are 0.01 amps. | 1.3.6.1.4.1.19536.10.1.2.3.1.5 | Integer32 (0..16) | read-write | current |
| pdug5InputRcmThChangeDelay OBJECT-TYPE The number of consecutive sample that the condition is present before an alarm is raised. | 1.3.6.1.4.1.19536.10.1.2.3.1.6 | Integer32 (0..100) | read-write | current |
| pdug5InputRcmThCtrl OBJECT-TYPE Rcm current alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable. | 1.3.6.1.4.1.19536.10.1.2.3.1.7 | Integer32 | read-write | current |
| pdug5InputRcmThStatus OBJECT-TYPE Status of the measured Rcm current relative to the configured thresholds. | 1.3.6.1.4.1.19536.10.1.2.3.1.8 | INTEGER {featureNotAvailable(-1), good(1), highWarning(4), highCritical(5)} | read-only | current |
| pdug5InputRcmCurrent OBJECT-TYPE Rcm module current reading. Units are milliAmps. | 1.3.6.1.4.1.19536.10.1.2.3.1.9 | Integer32 | read-only | current |
| pdug5InputRcmSelfTestTable OBJECT-TYPE Aggregate Object with number of entries equal to number of PDUs (pdug5NumberPDU) and number of Rcm modules per PDU. | 1.3.6.1.4.1.19536.10.1.2.4 | not-accessible | current | |
| pdug5InputRcmSelfTestEntry OBJECT-TYPE The ident table entry containing the Rcm Module Self Test Enable, Schedule, LastRunTime,LastRunStatus etc. | 1.3.6.1.4.1.19536.10.1.2.4.1 | not-accessible | current | |
| pdug5InputRcmSelfTestEnable OBJECT-TYPE Rcm Self Test configuration value Disable(0) if the self test is disabled on the PDU, Enable(1) if self test is enabled on the PDU . | 1.3.6.1.4.1.19536.10.1.2.4.1.1 | INTEGER {featureNotAvailable(-1), disable(0), enable(1)} | read-write | current |
| pdug5InputRcmSelfTestFreq OBJECT-TYPE Rcm module self test run frequency , the time for the test is set from Pdug5RcmSelfTestNextRunTime, the self test will be repeated based on the setting as Daily(1),Weekly(2),First Day Of Month(3),Yearly(4) | 1.3.6.1.4.1.19536.10.1.2.4.1.2 | INTEGER {featureNotAvailable(-1), daily(1), weekly(2), monthly(3), yearly(4)} | read-write | current |
| pdug5InputRcmSelfTestHour OBJECT-TYPE Rcm module self test schedule hour setting,-1 means feature not available | 1.3.6.1.4.1.19536.10.1.2.4.1.3 | Integer32 (-1..23) | read-write | current |
| pdug5InputRcmSelfTestMinute OBJECT-TYPE Rcm module self test schedule minute setting,-1 means feature not available | 1.3.6.1.4.1.19536.10.1.2.4.1.4 | Integer32 (-1..59) | read-write | current |
| pdug5InputRcmSelfTestDay OBJECT-TYPE Rcm module self test schedule day setting,-1 means feature not available | 1.3.6.1.4.1.19536.10.1.2.4.1.5 | INTEGER {featureNotAvailable(-1), sunday(0), monday(1), tuesday(2), wednesday(3), thursday(4), friday(5), saturday(6)} | read-write | current |
| pdug5InputRcmSelfTestMonth OBJECT-TYPE Rcm module self test schedule month setting,-1 means feature not available | 1.3.6.1.4.1.19536.10.1.2.4.1.6 | INTEGER {featureNotAvailable(-1), january(0), february(1), march(2), april(3), may(4), june(5), july(6), august(7), september(8), october(9), november(10), december(11)} | read-write | current |
| pdug5InputRcmSelfTestNextRunTime OBJECT-TYPE next run date and Time for self test. | 1.3.6.1.4.1.19536.10.1.2.4.1.7 | DisplayString | read-only | current |
| pdug5InputRcmSelfTestLastRunTime OBJECT-TYPE Date and Time when the self test run previously | 1.3.6.1.4.1.19536.10.1.2.4.1.8 | DisplayString | read-only | current |
| pdug5InputRcmSelfTestLastRunStatus OBJECT-TYPE Status of the lastest self test run | 1.3.6.1.4.1.19536.10.1.2.4.1.9 | INTEGER {featureNotAvailable(-1), passed(1), failed(2), pending(3)} | read-only | current |
| pdug5Group OBJECT-IDENTITY | 1.3.6.1.4.1.19536.10.1.3 | |||
| pdug5GroupTable OBJECT-TYPE Aggregate Object with number of entries equal to number of PDUs and number of breakers (pdug5GroupCount). | 1.3.6.1.4.1.19536.10.1.3.1 | not-accessible | current | |
| pdug5GroupEntry OBJECT-TYPE The input table entry containing the name, voltages, currents, power, etc. | 1.3.6.1.4.1.19536.10.1.3.1.1 | not-accessible | current | |
| pdug5GroupIndex OBJECT-TYPE Index for the pdug5GroupEntry table. | 1.3.6.1.4.1.19536.10.1.3.1.1.1 | Integer32 (0..12) | not-accessible | current |
| pdug5GroupName OBJECT-TYPE A descriptive name for the group. | 1.3.6.1.4.1.19536.10.1.3.1.1.2 | DisplayString (SIZE(1..31)) | read-write | current |
| pdug5GroupType OBJECT-TYPE The type of the group. (5) has no breaker | 1.3.6.1.4.1.19536.10.1.3.1.1.3 | INTEGER {breaker1pole(2), breaker2pole(3), breaker3pole(4), outletSection(5)} | read-only | current |
| pdug5GroupVoltageMeasType OBJECT-TYPE Value indicates what input voltage is being measured in this table row - single phase voltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2, phase 2 to phase 3, or phase 3 to phase 1. | 1.3.6.1.4.1.19536.10.1.3.1.1.4 | INTEGER {singlePhase(1), phase1toN(2), phase2toN(3), phase3toN(4), phase1to2(5), phase2to3(6), phase3to1(7)} | read-only | current |
| pdug5GroupVoltage OBJECT-TYPE Units are 0.1 volts. | 1.3.6.1.4.1.19536.10.1.3.1.1.5 | Integer32 | read-only | current |
| pdug5GroupVoltageThStatus OBJECT-TYPE Status of the measured group voltage relative to the configured thresholds. | 1.3.6.1.4.1.19536.10.1.3.1.1.6 | INTEGER {good(1), lowWarning(2), lowCritical(3), highWarning(4), highCritical(5)} | read-only | current |
| pdug5GroupVoltageThLowerWarning OBJECT-TYPE Lower warning threshold. Units are 0.1 volts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.3.1.1.7 | Integer32 (-1..500000) | read-only | current |
| pdug5GroupVoltageThLowerCritical OBJECT-TYPE Lower critical threshold. Units are 0.1 volts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.3.1.1.8 | Integer32 (-1..500000) | read-only | current |
| pdug5GroupVoltageThUpperWarning OBJECT-TYPE Upper warning threshold. Units are 0.1 volts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.3.1.1.9 | Integer32 (-1..500000) | read-only | current |
| pdug5GroupVoltageThUpperCritical OBJECT-TYPE Upper critical threshold. Units are 0.1 volts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.3.1.1.10 | Integer32 (-1..500000) | read-only | current |
| pdug5groupCurrentRating OBJECT-TYPE Rated current capacity of the group. Units are 0.01 amps. A negative value indicates that the hardware current capacity is unknown (it will always be unknown for custom groups). | 1.3.6.1.4.1.19536.10.1.3.1.1.11 | Integer32 | read-only | current |
| pdug5GroupCurrent OBJECT-TYPE A group current measurement value. Units are 0.01 amps. | 1.3.6.1.4.1.19536.10.1.3.1.1.12 | Integer32 | read-only | current |
| pdug5GroupCurrentThStatus OBJECT-TYPE Status of the measured group current relative to the configured thresholds. | 1.3.6.1.4.1.19536.10.1.3.1.1.13 | INTEGER {good(1), lowWarning(2), lowCritical(3), highWarning(4), highCritical(5), cbOff(6)} | read-only | current |
| pdug5GroupCurrentThLowerWarning OBJECT-TYPE Lower warning threshold. Units are 0.01 amps. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.3.1.1.14 | Integer32 (-1..100000) | read-write | current |
| pdug5GroupCurrentThLowerCritical OBJECT-TYPE Lower critical threshold. Units are 0.01 amps. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.3.1.1.15 | Integer32 (-1..100000) | read-write | current |
| pdug5GroupCurrentThUpperWarning OBJECT-TYPE Upper warning threshold. Units are 0.01 amps. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.3.1.1.16 | Integer32 (-1..100000) | read-write | current |
| pdug5GroupCurrentThUpperCritical OBJECT-TYPE Upper critical threshold. Units are 0.01 amps. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.3.1.1.17 | Integer32 (-1..100000) | read-write | current |
| pdug5GroupCurrentPercentLoad OBJECT-TYPE Current percent load, based on the rated current capacity. Units are percentage, for example 80% will be returned as 80. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.3.1.1.18 | Integer32 | read-only | current |
| pdug5GroupPowerVA OBJECT-TYPE A group VA value. Units are VA. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.3.1.1.19 | Integer32 | read-only | current |
| pdug5GroupPowerWatts OBJECT-TYPE A group power value. Units are Watts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.3.1.1.20 | Integer32 | read-only | current |
| pdug5GroupPowerWattHour OBJECT-TYPE A Watt-Hour value for each section. Units are WH. This value can be reset to 0 using GUI. In that case, the pdug5GroupPowerWattHourTimer will be reset as well. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.3.1.1.21 | Integer32 | read-only | current |
| pdug5GroupPowerWattHourTimer OBJECT-TYPE Timestamp of when group Watt-hours (groupWh) was last reset. | 1.3.6.1.4.1.19536.10.1.3.1.1.22 | DisplayString (SIZE(0..22)) | read-only | current |
| pdug5GroupPowerFactor OBJECT-TYPE A group PF value. Units are in hundredths, for example a power factor of 0.95 would be returned as 95, and 0.92 would be returned as 92. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.3.1.1.23 | Integer32 | read-only | current |
| pdug5GroupPowerVAR OBJECT-TYPE A group VAR value. Units are VAR. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.3.1.1.24 | Integer32 | read-only | current |
| pdug5GroupOutletCount OBJECT-TYPE The number of outlets in each group (breaker). | 1.3.6.1.4.1.19536.10.1.3.1.1.25 | Integer32 (0..48) | read-only | current |
| pdug5GroupBreakerStatus OBJECT-TYPE Only applicable to groups with breaker. Indicates whether a breaker is turned off or on. | 1.3.6.1.4.1.19536.10.1.3.1.1.26 | INTEGER {notApplicable(1), breakerOn(2), breakerOff(3)} | read-only | current |
| pdug5GroupVoltageThCtrl OBJECT-TYPE Circuit Breaker voltage alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable | 1.3.6.1.4.1.19536.10.1.3.1.1.27 | Integer32 | read-only | current |
| pdug5GroupCurrentThCtrl OBJECT-TYPE Circuit Breaker current alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable | 1.3.6.1.4.1.19536.10.1.3.1.1.28 | Integer32 | read-write | current |
| pdug5Environment OBJECT-IDENTITY | 1.3.6.1.4.1.19536.10.1.4 | |||
| pdug5EnvProbeTable OBJECT-TYPE A list of environment probe (1 per PDU) for temperature, humidity, and contacts. The number of entries is given by number of PDUs in daisy chain. | 1.3.6.1.4.1.19536.10.1.4.1 | not-accessible | current | |
| pdug5EnvProbeEntry OBJECT-TYPE Aggregate entries equal to number of PDUs. | 1.3.6.1.4.1.19536.10.1.4.1.1 | not-accessible | current | |
| pdug5TemperatureScale OBJECT-TYPE Scale used to return temperature objects. | 1.3.6.1.4.1.19536.10.1.4.1.1.1 | INTEGER {celsius(1), fahrenheit(2)} | read-write | current |
| pdug5TemperatureCount OBJECT-TYPE The number of temperature measurements.The MAX is 6 (1 per probe). | 1.3.6.1.4.1.19536.10.1.4.1.1.2 | Integer32 | read-only | current |
| pdug5HumidityCount OBJECT-TYPE The number of humidity measurements.The MAX is 6(1 per probe). | 1.3.6.1.4.1.19536.10.1.4.1.1.3 | Integer32 | read-only | current |
| pdug5DoorCount OBJECT-TYPE The number of door sensors.The MAX is 6(1 per probe). | 1.3.6.1.4.1.19536.10.1.4.1.1.4 | Integer32 | read-only | current |
| pdug5DryCount OBJECT-TYPE The number of dry sensors.The MAX is 2(1 per probe). | 1.3.6.1.4.1.19536.10.1.4.1.1.5 | Integer32 | read-only | current |
| pdug5SpotCount OBJECT-TYPE The number of spot sensors.The MAX is 2(1 per probe). | 1.3.6.1.4.1.19536.10.1.4.1.1.6 | Integer32 | read-only | current |
| pdug5RopeCount OBJECT-TYPE The number of rope sensors.The MAX is 2(1 per probe). | 1.3.6.1.4.1.19536.10.1.4.1.1.7 | Integer32 | read-only | current |
| pdug5HidCount OBJECT-TYPE The number of hid sensors. The MAX is 2(1 per probe). | 1.3.6.1.4.1.19536.10.1.4.1.1.10 | Integer32 | read-only | current |
| pdug5TemperatureTable OBJECT-TYPE A list of temperature probe measurements. The number of entries are given by number of pdu and pdug5TemperatureCount. | 1.3.6.1.4.1.19536.10.1.4.2 | not-accessible | current | |
| pdug5TemperatureEntry OBJECT-TYPE An entry for a temperature measurement. | 1.3.6.1.4.1.19536.10.1.4.2.1 | not-accessible | current | |
| pdug5TemperatureIndex OBJECT-TYPE A unique value for each temperature probe measurement. Its value ranges from 1 to temperatureCount. | 1.3.6.1.4.1.19536.10.1.4.2.1.1 | Integer32 (1..6) | not-accessible | current |
| pdug5TemperatureName OBJECT-TYPE A descriptive name for the temperature probe. | 1.3.6.1.4.1.19536.10.1.4.2.1.2 | DisplayString (SIZE(1..15)) | read-write | current |
| pdug5TemperatureProbeStatus OBJECT-TYPE Indicates whether a probe is connected or not. | 1.3.6.1.4.1.19536.10.1.4.2.1.3 | INTEGER {disconnected(1), connected(2), bad(3)} | read-only | current |
| pdug5TemperatureValue OBJECT-TYPE Units are degree(either Fahrenheit or Celsius). | 1.3.6.1.4.1.19536.10.1.4.2.1.4 | Integer32 | read-only | current |
| pdug5TemperatureThStatus OBJECT-TYPE Status of the measured temperature relative to the configured thresholds. | 1.3.6.1.4.1.19536.10.1.4.2.1.5 | INTEGER {good(1), lowWarning(2), lowCritical(3), highWarning(4), highCritical(5)} | read-only | current |
| pdug5TemperatureThLowerWarning OBJECT-TYPE Lower warning threshold. Units are degrees. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.4.2.1.6 | Integer32 (-1..150000) | read-write | current |
| pdug5TemperatureThLowerCritical OBJECT-TYPE Lower critical threshold. Units are degrees. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.4.2.1.7 | Integer32 (-1..150000) | read-write | current |
| pdug5TemperatureThUpperWarning OBJECT-TYPE Upper warning threshold. Units are degrees. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.4.2.1.8 | Integer32 (-1..150000) | read-write | current |
| pdug5TemperatureThUpperCritical OBJECT-TYPE Upper critical threshold. Units are degrees. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.4.2.1.9 | Integer32 (-1..150000) | read-write | current |
| pdug5TemperatureThCtrl OBJECT-TYPE Temperature alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable | 1.3.6.1.4.1.19536.10.1.4.2.1.10 | Integer32 | read-write | current |
| pdug5HumidityTable OBJECT-TYPE A list of humidity probe measurements. The number of entries are given by number of pdu and pdug5HumidityCount. | 1.3.6.1.4.1.19536.10.1.4.3 | not-accessible | current | |
| pdug5HumidityEntry OBJECT-TYPE An entry for a humidity measurement. | 1.3.6.1.4.1.19536.10.1.4.3.1 | not-accessible | current | |
| pdug5HumidityIndex OBJECT-TYPE A unique value for each humidity probe measurement. Its value ranges from 1 to pdug5HumidityCount per PDU. | 1.3.6.1.4.1.19536.10.1.4.3.1.1 | Integer32 (1..6) | not-accessible | current |
| pdug5HumidityName OBJECT-TYPE A descriptive name for the humidity probe. | 1.3.6.1.4.1.19536.10.1.4.3.1.2 | DisplayString (SIZE(1..15)) | read-write | current |
| pdug5HumidityProbeStatus OBJECT-TYPE Indicates whether a probe is connected or not. | 1.3.6.1.4.1.19536.10.1.4.3.1.3 | INTEGER {disconnected(1), connected(2), bad(3)} | read-only | current |
| pdug5HumidityValue OBJECT-TYPE Units are %RH. | 1.3.6.1.4.1.19536.10.1.4.3.1.4 | Integer32 | read-only | current |
| pdug5HumidityThStatus OBJECT-TYPE Status of the measured humidity relative to the configured thresholds. | 1.3.6.1.4.1.19536.10.1.4.3.1.5 | INTEGER {good(1), lowWarning(2), lowCritical(3), highWarning(4), highCritical(5)} | read-only | current |
| pdug5HumidityThLowerWarning OBJECT-TYPE Lower warning threshold. Units are %RH. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.4.3.1.6 | Integer32 (-1..1000) | read-write | current |
| pdug5HumidityThLowerCritical OBJECT-TYPE Lower critical threshold. Units are %RH. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.4.3.1.7 | Integer32 (-1..1000) | read-write | current |
| pdug5HumidityThUpperWarning OBJECT-TYPE Upper warning threshold. Units are %RH. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.4.3.1.8 | Integer32 (-1..1000) | read-write | current |
| pdug5HumidityThUpperCritical OBJECT-TYPE Upper critical threshold. Units are %RH. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.4.3.1.9 | Integer32 (-1..1000) | read-write | current |
| pdug5HumidityThCtrl OBJECT-TYPE Humidity alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable | 1.3.6.1.4.1.19536.10.1.4.3.1.10 | Integer32 | read-write | current |
| pdug5DoorTable OBJECT-TYPE A list of door sensors. The number of entries are given by number of PDU and pdug5DoorCount. | 1.3.6.1.4.1.19536.10.1.4.4 | not-accessible | current | |
| pdug5DoorEntry OBJECT-TYPE An entry for a door sensor | 1.3.6.1.4.1.19536.10.1.4.4.1 | not-accessible | current | |
| pdug5DoorIndex OBJECT-TYPE A unique value for each door sensor. Its value ranges from 1 to doorCount. | 1.3.6.1.4.1.19536.10.1.4.4.1.1 | Integer32 (1..2) | not-accessible | current |
| pdug5DoorName OBJECT-TYPE A descriptive name for the door sensor. | 1.3.6.1.4.1.19536.10.1.4.4.1.2 | DisplayString (SIZE(1..15)) | read-write | current |
| pdug5DoorProbeStatus OBJECT-TYPE Indicates whether a probe is connected or not. Will not be returned if the door sensor is internal to the ePDU, in that case only doorState should be read. | 1.3.6.1.4.1.19536.10.1.4.4.1.3 | INTEGER {disconnected(1), connected(2), bad(3)} | read-only | current |
| pdug5DoorState OBJECT-TYPE The state of the door sensor. | 1.3.6.1.4.1.19536.10.1.4.4.1.4 | INTEGER {doorOpen(1), doorClosed(2), badDoorSensor(3)} | read-only | current |
| pdug5DryTable OBJECT-TYPE A list of dry sensors. The number of entries are given by number of pdu and pdug5DryCount. | 1.3.6.1.4.1.19536.10.1.4.5 | not-accessible | current | |
| pdug5DryEntry OBJECT-TYPE An entry for a contact sensor | 1.3.6.1.4.1.19536.10.1.4.5.1 | not-accessible | current | |
| pdug5DryIndex OBJECT-TYPE A unique value for each dry sensor. Its value ranges from 1 to dryCount. | 1.3.6.1.4.1.19536.10.1.4.5.1.1 | Integer32 (1..2) | not-accessible | current |
| pdug5DryName OBJECT-TYPE A descriptive name for the dry sensor. | 1.3.6.1.4.1.19536.10.1.4.5.1.2 | DisplayString (SIZE(1..15)) | read-write | current |
| pdug5DryProbeStatus OBJECT-TYPE Indicates whether a probe is connected or not. | 1.3.6.1.4.1.19536.10.1.4.5.1.3 | INTEGER {disconnected(1), connected(2), bad(3)} | read-only | current |
| pdug5DryState OBJECT-TYPE The state of the dry sensor. | 1.3.6.1.4.1.19536.10.1.4.5.1.4 | INTEGER {good(1), alarmed(2)} | read-only | current |
| pdug5SpotTable OBJECT-TYPE A list of contact sensors. The number of entries are given by number of pdu and pdug5SpotCount. | 1.3.6.1.4.1.19536.10.1.4.6 | not-accessible | current | |
| pdug5SpotEntry OBJECT-TYPE An entry for a contact sensor | 1.3.6.1.4.1.19536.10.1.4.6.1 | not-accessible | current | |
| pdug5SpotIndex OBJECT-TYPE A unique value for each spot sensor. Its value ranges from 1 to spotCount. | 1.3.6.1.4.1.19536.10.1.4.6.1.1 | Integer32 (1..3) | not-accessible | current |
| pdug5SpotName OBJECT-TYPE A descriptive name for the spot sensor. | 1.3.6.1.4.1.19536.10.1.4.6.1.2 | DisplayString (SIZE(1..15)) | read-write | current |
| pdug5SpotProbeStatus OBJECT-TYPE Indicates whether a probe is connected or not. | 1.3.6.1.4.1.19536.10.1.4.6.1.3 | INTEGER {disconnected(1), connected(2), bad(3)} | read-only | current |
| pdug5SpotState OBJECT-TYPE The state of the spot sensor. | 1.3.6.1.4.1.19536.10.1.4.6.1.4 | INTEGER {noleak(1), leak(2)} | read-only | current |
| pdug5RopeTable OBJECT-TYPE A list of rope sensors. The number of entries are given by number of pdu and pdug5RopeCount. | 1.3.6.1.4.1.19536.10.1.4.7 | not-accessible | current | |
| pdug5RopeEntry OBJECT-TYPE An entry for a contact sensor | 1.3.6.1.4.1.19536.10.1.4.7.1 | not-accessible | current | |
| pdug5RopeIndex OBJECT-TYPE A unique value for each rope sensor. Its value ranges from 1 to ropeCount. | 1.3.6.1.4.1.19536.10.1.4.7.1.1 | Integer32 (1..3) | not-accessible | current |
| pdug5RopeName OBJECT-TYPE A descriptive name for the rope sensor. | 1.3.6.1.4.1.19536.10.1.4.7.1.2 | DisplayString (SIZE(1..15)) | read-write | current |
| pdug5RopeProbeStatus OBJECT-TYPE Indicates whether a probe is connected or not. | 1.3.6.1.4.1.19536.10.1.4.7.1.3 | INTEGER {disconnected(1), connected(2), bad(3)} | read-only | current |
| pdug5RopeState OBJECT-TYPE The state of the rope sensor. | 1.3.6.1.4.1.19536.10.1.4.7.1.4 | INTEGER {noleak(1), leak(2)} | read-only | current |
| pdug5EnvHID OBJECT-IDENTITY | 1.3.6.1.4.1.19536.10.1.4.10 | |||
| pdug5EnvHidTable OBJECT-TYPE A list of contact sensors. The number of entries are given by number of pdu and pdug5HidCount. | 1.3.6.1.4.1.19536.10.1.4.10.1 | not-accessible | current | |
| pdug5EnvHidEntry OBJECT-TYPE An entry for a contact sensor | 1.3.6.1.4.1.19536.10.1.4.10.1.1 | not-accessible | current | |
| pdug5HIDIndex OBJECT-TYPE The index of the PDU HID table entry | 1.3.6.1.4.1.19536.10.1.4.10.1.1.1 | Integer32 (1..2) | not-accessible | current |
| pdug5HidAisle OBJECT-TYPE Aisle of HID handle. | 1.3.6.1.4.1.19536.10.1.4.10.1.1.2 | INTEGER {cold(1), hot(2)} | read-only | current |
| pdug5HidHandleOperation OBJECT-TYPE HID handle control operations | 1.3.6.1.4.1.19536.10.1.4.10.1.1.3 | INTEGER {unlock(1), lock(2)} | read-write | current |
| pduHIDVer OBJECT-TYPE The firmware revision level of the HID | 1.3.6.1.4.1.19536.10.1.4.10.1.1.4 | DisplayString (SIZE(0..63)) | read-only | current |
| pdug5MechanicalLock OBJECT-TYPE HID Mechanical operations | 1.3.6.1.4.1.19536.10.1.4.10.1.1.5 | INTEGER {unlock(1), lock(2)} | read-only | current |
| pduHIDSerial OBJECT-TYPE The Serial Number of the HID | 1.3.6.1.4.1.19536.10.1.4.10.1.1.6 | DisplayString (SIZE(0..63)) | read-only | current |
| pduHIDHwVer OBJECT-TYPE The hardware revision level of the HID | 1.3.6.1.4.1.19536.10.1.4.10.1.1.7 | DisplayString (SIZE(0..63)) | read-only | current |
| pdug5HIDAutoLockTime OBJECT-TYPE HID Electronic Latch Autolock Time in seconds, Value ranges (0-999) | 1.3.6.1.4.1.19536.10.1.4.10.1.1.8 | Integer32 | read-write | current |
| pdug5HIDDoorOpenTime OBJECT-TYPE HID Door Open Time in seconds, Value ranges (0-999) | 1.3.6.1.4.1.19536.10.1.4.10.1.1.9 | Integer32 | read-write | current |
| pdug5HIDMaxDoorOpenTime OBJECT-TYPE HID Max Door Open Time in seconds, Value ranges (0-32400), critical alarm will be raised if door is left open past this time | 1.3.6.1.4.1.19536.10.1.4.10.1.1.10 | Integer32 | read-write | current |
| pdug5HIDUserPinLength OBJECT-TYPE Rack Access User minimum PIN Length, value ranges(0-16) | 1.3.6.1.4.1.19536.10.1.4.10.1.1.11 | Integer32 | read-write | current |
| pdug5HIDUserPinMode OBJECT-TYPE Rack Access User PIN mode setting | 1.3.6.1.4.1.19536.10.1.4.10.1.1.12 | INTEGER {visible(1), hidden(2)} | read-write | current |
| pdug5HIDAisleControl OBJECT-TYPE Rack Access Aisle Control setting, when set to standalone each aisle will controlled separately, when set to combined opposite aisle can be controlled with authenticated control action on either aisle | 1.3.6.1.4.1.19536.10.1.4.10.1.1.13 | INTEGER {combined(1), standalone(2)} | read-write | current |
| pdug5HIDBeaconFuncControl OBJECT-TYPE Beacon Function Control | 1.3.6.1.4.1.19536.10.1.4.10.1.1.14 | INTEGER {locate(0), standby(1)} | read-write | current |
| pdug5HidBeaconColorControl OBJECT-TYPE Beacon Color Control | 1.3.6.1.4.1.19536.10.1.4.10.1.1.15 | INTEGER {red(0), green(1), blue(2), yellow(3), magenta(4), aqua(5), white(6), beaconoff(7)} | read-write | current |
| pdug5EnvHidControlTable OBJECT-TYPE A list of smartcard. The number of entries are given by number of pdu and pdug5HidCount. | 1.3.6.1.4.1.19536.10.1.4.10.2 | not-accessible | current | |
| pdug5EnvHidControlEntry OBJECT-TYPE The smart card table entry containing the username, cardid, cardaisle etc. | 1.3.6.1.4.1.19536.10.1.4.10.2.1 | not-accessible | current | |
| pdug5HidControlIndex OBJECT-TYPE The index of the PDU smartcard table entry | 1.3.6.1.4.1.19536.10.1.4.10.2.1.1 | Integer32 (1..200) | not-accessible | current |
| pdug5HidControlUserName OBJECT-TYPE User name of smartcard. Use #delete# to delete the HID user | 1.3.6.1.4.1.19536.10.1.4.10.2.1.2 | DisplayString | read-write | current |
| pdug5HidControlCardID OBJECT-TYPE HID smartcard ID. | 1.3.6.1.4.1.19536.10.1.4.10.2.1.3 | Integer32 | read-write | current |
| pdug5HidControlTimestamp OBJECT-TYPE Indicates the date and time of accessing | 1.3.6.1.4.1.19536.10.1.4.10.2.1.4 | DisplayString | read-only | current |
| pdug5HidControlCardAisle OBJECT-TYPE Aisle of authorized card | 1.3.6.1.4.1.19536.10.1.4.10.2.1.5 | INTEGER {cold(1), hot(2), both(3)} | read-write | current |
| pdug5HidControlStartTime OBJECT-TYPE Indicates the start date and time Rack access user is given access | 1.3.6.1.4.1.19536.10.1.4.10.2.1.6 | DisplayString | read-write | current |
| pdug5HidControlExpireTime OBJECT-TYPE Indicates the date and time when the access of user card will expire, To set expire time first set user as temporary user | 1.3.6.1.4.1.19536.10.1.4.10.2.1.7 | DisplayString | read-write | current |
| pdug5HidControlTempUser OBJECT-TYPE Indicates if the card user has temporary access | 1.3.6.1.4.1.19536.10.1.4.10.2.1.8 | INTEGER {no(1), yes(2)} | read-write | current |
| pdug5HidControlPin OBJECT-TYPE Rack access control entry keypad PIN | 1.3.6.1.4.1.19536.10.1.4.10.2.1.9 | DisplayString | read-write | current |
| pdug5HidControlCardIdStr OBJECT-TYPE Smartrack Access Card ID String | 1.3.6.1.4.1.19536.10.1.4.10.2.1.10 | DisplayString | read-write | current |
| pdug5Outlet OBJECT-IDENTITY | 1.3.6.1.4.1.19536.10.1.5 | |||
| pdug5OutletTable OBJECT-TYPE Aggregate Object with number of entries equal to Number of PDU (pdug5IdentIndex) and Number of outlet per PDU (pdug5OutletIndex). | 1.3.6.1.4.1.19536.10.1.5.1 | not-accessible | current | |
| pdug5OutletEntry OBJECT-TYPE The Outlet table entry containing the type, voltage, current etc. | 1.3.6.1.4.1.19536.10.1.5.1.1 | not-accessible | current | |
| pdug5OutletIndex OBJECT-TYPE Index for each outlet, value from 1 to the number of outlets per PDU. | 1.3.6.1.4.1.19536.10.1.5.1.1.1 | Integer32 (0..48) | not-accessible | current |
| pdug5OutletName OBJECT-TYPE A descriptive name for the outlet. | 1.3.6.1.4.1.19536.10.1.5.1.1.2 | DisplayString (SIZE(1..31)) | read-write | current |
| pdug5OutletType OBJECT-TYPE Type of this outlet - C13, C19, 5-20R, iecC13/C15 COMBO, iecC13/C15/C19 COMBO... | 1.3.6.1.4.1.19536.10.1.5.1.1.3 | INTEGER {iecC13(1), iecC19(2), nema5-20R(3), iecC13iecC15combo(4), iecC13iecC15iec19combo(5), uk(10), french(11), schuko(12), nema515(20), nema51520(21), nema520(22), nemaL520(23), nemaL530(24), nema615(25), nema620(26), nemaL620(27), nemaL630(28), nemaL715(29), rf203p277(30)} | read-only | current |
| pdug5OutletCurrentRating OBJECT-TYPE Rated current capacity of this outlet. Units are 0.01 amps. A negative value indicates that the hardware current capacity is unknown. | 1.3.6.1.4.1.19536.10.1.5.1.1.4 | Integer32 | read-only | current |
| pdug5OutletCurrent OBJECT-TYPE A outlet current measurement value. Units are 0.01 amps. | 1.3.6.1.4.1.19536.10.1.5.1.1.5 | Integer32 | read-only | current |
| pdug5OutletActivePowerThStatus OBJECT-TYPE Status of the measured outlet active power relative to the configured thresholds. | 1.3.6.1.4.1.19536.10.1.5.1.1.6 | INTEGER {good(1), lowWarning(2), lowCritical(3), highWarning(4), highCritical(5)} | read-only | current |
| pdug5OutletActivePowerThLowerWarning OBJECT-TYPE Lower warning threshold. Units are Watts(W). A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.5.1.1.7 | Integer32 (-1..10000) | read-write | current |
| pdug5OutletActivePowerThLowerCritical OBJECT-TYPE Lower critical threshold. Units are Watts(W). A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.5.1.1.8 | Integer32 (-1..10000) | read-write | current |
| pdug5OutletActivePowerThUpperWarning OBJECT-TYPE Upper warning threshold. Units are Watts(W). A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.5.1.1.9 | Integer32 (-1..10000) | read-write | current |
| pdug5OutletActivePowerThUpperCritical OBJECT-TYPE Upper critical threshold. Units are Watts(W). A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.5.1.1.10 | Integer32 (-1..10000) | read-write | current |
| pdug5OutletCurrentPercentLoad OBJECT-TYPE Current percent load, based on the rated current capacity. Units are percentage, for example 80% will be returned as 80. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.5.1.1.11 | Integer32 | read-only | current |
| pdug5OutletVA OBJECT-TYPE A outlet VA value. Units are VA. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.5.1.1.12 | Integer32 | read-only | current |
| pdug5OutletWatts OBJECT-TYPE A outlet Watts value. Units are Watts. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.5.1.1.13 | Integer32 | read-only | current |
| pdug5OutletWh OBJECT-TYPE A Watt-Hour value for each outlet. Units are WH. This object is writable so that it can be reset to 0. When it is written to, the pdug5OutletWhTimer will be reset updated as well A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.5.1.1.14 | Integer32 | read-only | current |
| pdug5OutletWhTimer OBJECT-TYPE Timestamp (date and time) of outlet Watt-hours was last reset. | 1.3.6.1.4.1.19536.10.1.5.1.1.15 | DisplayString (SIZE(0..22)) | read-only | current |
| pdug5OutletPowerFactor OBJECT-TYPE An outlet PF value. Units are in hundredths, for example a power factor of 0.95 would be returned as 95, and 0.92 would be returned as 92. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.5.1.1.16 | Integer32 | read-only | current |
| pdug5OutletVAR OBJECT-TYPE An outlet VAR value. Units are VAR. A negative value indicates that this object is not available. | 1.3.6.1.4.1.19536.10.1.5.1.1.17 | Integer32 | read-only | current |
| pdug5OutletBranch OBJECT-TYPE The branch number outlet located. | 1.3.6.1.4.1.19536.10.1.5.1.1.18 | Integer32 | read-only | current |
| pdug5OutletActivePowerThResetThld OBJECT-TYPE The Reset threshold is the number of watss the reading needs to fall below the threshold setting for the condition to be cleared. Units are watts. | 1.3.6.1.4.1.19536.10.1.5.1.1.19 | Integer32 (-1..10000) | read-write | current |
| pdug5OutletActivePowerThChangeDelay OBJECT-TYPE The number of consecutive sample that the condition is present before an alarm is raised. | 1.3.6.1.4.1.19536.10.1.5.1.1.20 | Integer32 (0..100) | read-write | current |
| pdug5OutletActivePowerThCtrl OBJECT-TYPE Outlet Active Power alarm threshold control: bit 0: up critical alarm control bit, 0 - enable, 1 - disable bit 1: up warning alarm control bit, 0 - enable, 1 - disable bit 2: low warning alarm control bit, 0 - enable, 1 - disable bit 3: low critical alarm control bit, 0 - enable, 1 - disable | 1.3.6.1.4.1.19536.10.1.5.1.1.21 | Integer32 | read-write | current |
| pdug5OutletControlTable OBJECT-TYPE Aggregate Object with number of entries equal to Number of PDU (pdug5IdentIndex) and Number of outlets per PDU (pdug5OutletIndex). | 1.3.6.1.4.1.19536.10.1.5.2 | not-accessible | current | |
| pdug5OutletControlEntry OBJECT-TYPE The Outlet table entry containing the type, voltage, current etc. | 1.3.6.1.4.1.19536.10.1.5.2.1 | not-accessible | current | |
| pdug5OutletControlStatus OBJECT-TYPE current state of a control outlet. | 1.3.6.1.4.1.19536.10.1.5.2.1.1 | INTEGER {off(1), on(2), pendingOff(3), pendingOn(4)} | read-only | current |
| pdug5OutletControlOffCmd OBJECT-TYPE When write, once issued, the outlet will turn Off immediately. 0-n: Time in seconds until the outlet command is issued -1: Cancel a pending outlet Off command When read, returns -1 if no command is pending, or the current downcount in seconds of a pending command. | 1.3.6.1.4.1.19536.10.1.5.2.1.2 | Integer32 (-1..99999) | read-write | current |
| pdug5OutletControlOnCmd OBJECT-TYPE When write, once issued, the outlet will turn On immediately. 0-n: Time in seconds until the outlet command is issued -1: Cancel a pending outlet On command When read, returns -1 if no command is pending, or the current downcount in seconds of a pending command. | 1.3.6.1.4.1.19536.10.1.5.2.1.3 | Integer32 (-1..99999) | read-write | current |
| pdug5OutletControlRebootCmd OBJECT-TYPE When write, for outlets that are On prior to this Reboot command, they will switch Off immediately when the command is issued, remain Off for outletControlRebootOffTime seconds, and then turn back On. For outlets that are Off prior to the Reboot command, they will turn On after a delay of outletControlRebootOffTime seconds from when the command is issued. 0-n : Time in seconds until the Reboot command is issued -1 : Cancel a pending outlet Reboot command When read, returns -1 if no command is pending, or the current downcount in seconds of a pending command. | 1.3.6.1.4.1.19536.10.1.5.2.1.4 | Integer32 (-1..99999) | read-write | current |
| pdug5OutletControlPowerOnState OBJECT-TYPE Determines the outlet state when power is applied to the unit. 1 : not restart at device startup 2 : should sequence back ON in line with outletControlSequenceTime 3 : should take the state the outlet had when power was lost. If the state was ON, should sequence back ON in line with outletControlSequenceTime. | 1.3.6.1.4.1.19536.10.1.5.2.1.5 | INTEGER {off(1), on(2), lastState(3)} | read-write | current |
| pdug5OutletControlSequenceDelay OBJECT-TYPE Time delay in seconds from when a Global Sequence On command is issued to when the command is executed on this outlet. This delay is also used as a power-on delay. | 1.3.6.1.4.1.19536.10.1.5.2.1.6 | Integer32 (-1..7200) | read-write | current |
| pdug5OutletControlRebootOffTime OBJECT-TYPE Time delay in seconds that the outlet should remain in the Off state when executing a Reboot command. | 1.3.6.1.4.1.19536.10.1.5.2.1.7 | Integer32 (5..60) | read-write | current |
| pdug5OutletControlSwitchable OBJECT-TYPE Determines the outlet capability to be controlled On/Off from the communication channels. 1 : control On/Off enabled 2 : control On/Off disabled. | 1.3.6.1.4.1.19536.10.1.5.2.1.8 | INTEGER {switchable(1), notSwitchable(2)} | read-write | current |
| pdug5OutletControlShutoffDelay OBJECT-TYPE Time delay in seconds that could be taken in account before shutting of the outlet. An application which need to shutoff properly an outlet will read this parameter first then write it to the command pdug5OutletControlOffCmd. | 1.3.6.1.4.1.19536.10.1.5.2.1.9 | Integer32 (-1..7200) | read-write | current |
| pdug5OutletControlCommand OBJECT-TYPE Getting this variable will return the outlet state. If the outlet is on, the immediateOn (2) value will be returned. If the outlet is off, the immediateOff (1) value will be returned. If the state of the outlet cannot be determined, the outletUnknown (7) value will be returned. If the outletUnknown condition should occur, all devices powered by the PDU should be shut down. The PDU's power should then be cycled to clear this condition. Setting this variable to immediateOn (2) will immediately turn the outlet on. Setting this variable to immediateOff (1) will immediately turn the outlet off. Setting this variable to immediateReboot (5) will cause the Switched PDU to perform an immediateOff command, wait the pdug5OutletControlRebootOffTime OID time, and then perform an immediateOn command. Setting this variable to delayedOn (4) will turn the outlet on after the pdug5OutletControlSequenceDelay OID time has elapsed. Setting this variable to delayedOff (3) will turn the outlet off after the pdug5OutletControlShutoffDelay OID time has elapsed. Setting this variable to delayedReboot (6) will cause the Switched PDU to perform a delayedOff command, wait the pdug5OutletControlRebootOffTime OID time, and then perform a delayedOn command. | 1.3.6.1.4.1.19536.10.1.5.2.1.10 | INTEGER {immediateOff(1), immediateOn(2), delayedOff(3), delayedOn(4), immediateReboot(5), delayedReboot(6), outletUnknown(7)} | read-write | current |
| pdug5Traps OBJECT-IDENTITY | 1.3.6.1.4.1.19536.10.1.6 | |||
| pdug5TrapInfo OBJECT-IDENTITY | 1.3.6.1.4.1.19536.10.1.7 | |||
| pdug5TrapInfoEntry OBJECT-IDENTITY | 1.3.6.1.4.1.19536.10.1.7.1 | |||
| trapCode OBJECT-TYPE A number identifying the event for the trap that was sent. | 1.3.6.1.4.1.19536.10.1.7.1.1 | Integer32 | read-only | current |
| trapDescription OBJECT-TYPE A string identifying the event for that last trap that was sent. | 1.3.6.1.4.1.19536.10.1.7.1.2 | DisplayString (SIZE(0..255)) | read-only | current |
| pdug5Conformance OBJECT-IDENTITY | 1.3.6.1.4.1.19536.10.1.8 | |||
| pdug5Compliances OBJECT-IDENTITY | 1.3.6.1.4.1.19536.10.1.8.1 | |||
| pdug5Groups OBJECT-IDENTITY | 1.3.6.1.4.1.19536.10.1.8.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| trapCritical NOTIFICATION-TYPE A critical alarm has occurred. | 1.3.6.1.4.1.19536.10.1.6.1 | current |
| trapWarning NOTIFICATION-TYPE A warning alarm has occurred. | 1.3.6.1.4.1.19536.10.1.6.2 | current |
| trapInformation NOTIFICATION-TYPE An informational alarm has occurred. | 1.3.6.1.4.1.19536.10.1.6.3 | current |
| trapCleared NOTIFICATION-TYPE An alarm has cleared. | 1.3.6.1.4.1.19536.10.1.6.4 | current |
| trapTest NOTIFICATION-TYPE Test trap sent to a trap receiver to check proper reception of traps | 1.3.6.1.4.1.19536.10.1.6.5 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| pdug5FullCompliance MODULE-COMPLIANCE Compliance statement | 1.3.6.1.4.1.19536.10.1.8.1.1 | current |
| pdug5IdentGroup OBJECT-GROUP the pdug5Identity defines objects which aid PDU system level configuration | 1.3.6.1.4.1.19536.10.1.8.2.1 | current |
| pdug5InputGroup OBJECT-GROUP the pdug5InputGroup defines objects which aid Input level configuration and monitoring | 1.3.6.1.4.1.19536.10.1.8.2.2 | current |
| pdug5GroupGroup OBJECT-GROUP the pdug5GroupGroup defines objects which aid Breaker level configuration and monitoring | 1.3.6.1.4.1.19536.10.1.8.2.3 | current |
| pdug5EnvironmentGroup OBJECT-GROUP the pdug5Environmental defines objects which aid Environmental level configuration and monitoring | 1.3.6.1.4.1.19536.10.1.8.2.4 | current |
| pdug5OutletGroup OBJECT-GROUP the pdug5OutletGroup defines objects which aid Outlet level configuration and monitoring | 1.3.6.1.4.1.19536.10.1.8.2.5 | current |
| pdug5TrapGroup NOTIFICATION-GROUP the pdug5TrapGroup defines Traps. | 1.3.6.1.4.1.19536.10.1.8.2.6 | current |
| pdug5TrapInfoGroup OBJECT-GROUP the pdug5TrapInfoGroup defines Traps Information. | 1.3.6.1.4.1.19536.10.1.8.2.7 | current |