MIBs Depot

PACKETFRONT-DRG-MIB

Registered at
1.3.6.1.4.1.9303.4.3
Last updated
2009-03-23 15:38
Organization
PacketFront Systems AB
Revisions
2009-03-23 15:38, 2008-04-11 00:00
Namespace
waystream
Source file
PACKETFRONT-DRG-MIB
Digest
sha256:14844879c8a6e849d5576e49eb114d009d108eed80c444b466261a79497099e2

Description

The MIB module for managing Packetfront DRG devices

Contact

PacketFront Systems AB Customer Service Mail : Isafjordsgatan 35 SE-164 28 Kista Sweden Tel : +46 8 5090 1500 E-mail: snmp@packetfront.com Web : http://www.packetfront.com

Imports

FromSymbols
PACKETFRONT-SMIpfMgmt
PACKETFRONT-TCPortList
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, MacAddress, RowStatus, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

PACKETFRONT-DRG-MIB
PACKETFRONT-SMI
PACKETFRONT-TC
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
drgNotification
OBJECT-IDENTITY
1.3.6.1.4.1.9303.4.3.0
drgConfig
OBJECT-IDENTITY
1.3.6.1.4.1.9303.4.3.1
productInfo
OBJECT-IDENTITY
1.3.6.1.4.1.9303.4.3.1.1
productName
OBJECT-TYPE
The name of the product.
1.3.6.1.4.1.9303.4.3.1.1.1OCTET STRING (SIZE(0..16))read-onlycurrent
productSerialNo
OBJECT-TYPE
The unique serial number programmed into the device in the factory.
1.3.6.1.4.1.9303.4.3.1.1.2OCTET STRING (SIZE(0..10))read-onlycurrent
productProductionWeek
OBJECT-TYPE
The week and year in which this device was manufactured.
1.3.6.1.4.1.9303.4.3.1.1.3OCTET STRING (SIZE(0..8))read-onlycurrent
productSwImageRev
OBJECT-TYPE
The revision of the software in the device. This may be upgraded. E.g DMA0081-R2K123.
1.3.6.1.4.1.9303.4.3.1.1.4OCTET STRING (SIZE(0..32))read-onlycurrent
productFwImageRev
OBJECT-TYPE
The revision of the firmware in the device. This describes the bootloader revision, e.g. cxc_132_4098-R3A18.
1.3.6.1.4.1.9303.4.3.1.1.5OCTET STRING (SIZE(0..32))read-onlycurrent
productDefaultRevision
OBJECT-TYPE
The revision of the default configuration in the device. This describes the revision of information loaded during manufacture.
1.3.6.1.4.1.9303.4.3.1.1.6OCTET STRING (SIZE(0..8))read-onlycurrent
productOpDefRev
OBJECT-TYPE
The revision of the operator default information (the .ini file). The syntax is operator specific.Operator default revision ( INI file ).
1.3.6.1.4.1.9303.4.3.1.1.7OCTET STRING (SIZE(0..32))read-onlycurrent
productHardwareRev
OBJECT-TYPE
Manufacturing hardware information regarding the revision of the hardware.
1.3.6.1.4.1.9303.4.3.1.1.8OCTET STRING (SIZE(0..32))read-onlycurrent
productPlatform
OBJECT-TYPE
This provides a predefined string for each product family - this differs from productName in that this cannot be configured by the operator, therefore will be constant across all platforms of the same type irrespective of the operator-specific name for the platform. This is useful for network operators managing a heterogeneous mix of platforms from different service providers
1.3.6.1.4.1.9303.4.3.1.1.9OCTET STRING (SIZE(0..16))read-onlycurrent
productHardwarePCBARevision
OBJECT-TYPE
PCBA revision - this is a coded value read from the PCBA hardware.
1.3.6.1.4.1.9303.4.3.1.1.10Integer32read-onlycurrent
productFunctionIdentity
OBJECT-TYPE
Describes the functionality offered by the device.
1.3.6.1.4.1.9303.4.3.1.1.11OCTET STRING (SIZE(0..32))read-onlycurrent
productMacAddress
OBJECT-TYPE
The device MAC address - this is used in various alert messages to uniquely identify the specific device. The MAC address used is the MAC of the management entity of the device
1.3.6.1.4.1.9303.4.3.1.1.12MacAddressread-onlycurrent
productIdentity
OBJECT-TYPE
This object provides a unique identity for the device. By default this will be the same as the productMacAddress, however, if a hostname has been defined or provided by a DHCP server, then this will be used instead. In the former case, therefore, the identity is guaranteed to be unique, while in the latter it is the operator's responsibility to ensure that the identity is unique.
1.3.6.1.4.1.9303.4.3.1.1.13OCTET STRING (SIZE(0..32))read-onlycurrent
systemConfig
OBJECT-IDENTITY
1.3.6.1.4.1.9303.4.3.1.2
systemConfigRestartControl
OBJECT-TYPE
Setting this object to restartNow(2) causes the device to reboot immediately. Note that this will cause any unsave configuration changes to be lost, therefore configuration changes should be saved before using this value if the changes are required. The device returns running(1) in all other cases.
1.3.6.1.4.1.9303.4.3.1.2.1INTEGER {running(1), restartNow(2)}read-writecurrent
systemConfigRestartControlNotify
OBJECT-TYPE
This object controls the operation of the notifyRestart alert. The notifyRestart is sent repeatedly when the object is equal to notifying(2). The notifyRestart is not sent when the object is equal to silent(1).
1.3.6.1.4.1.9303.4.3.1.2.2INTEGER {silent(1), notifying(2)}read-writecurrent
systemConfigSave
OBJECT-TYPE
Setting the object to save(1) causes the running configuration to be saved. The object responds with changed(2) if the running configuration differs from the initial configuration. The object responds with notChanged(3) if no configuration changes have occurred since the last save or boot.
1.3.6.1.4.1.9303.4.3.1.2.3INTEGER {save(1), changed(2), notChanged(3)}read-writecurrent
systemConfigFactoryReset
OBJECT-TYPE
Setting this object to factoryReset(2) causes the device to return to its factory default settings, and reboot. This means that any operator or user configuration changes will be deleted, and the device will appear as if it has not previously been installed and configured. When read this object will return running(1) unless it is currently in the process of performing a factory reset.
1.3.6.1.4.1.9303.4.3.1.2.4INTEGER {running(1), factoryReset(2)}read-writecurrent
systemConfigSaveNotify
OBJECT-TYPE
Setting this object to always(2) will cause the device to send a notifyConfigSaveResult alert each time the configuration is saved. Setting this object to onlyErrors(3) will cause the device to send a notifyConfigSaveResult if an error occurs during a configuration save procedure. Setting this object to silent(1) causes the device to not send notifyConfigSaveResult alerts.
1.3.6.1.4.1.9303.4.3.1.2.5INTEGER {silent(1), always(2), onlyErrors(3)}read-writecurrent
downloadConfig
OBJECT-IDENTITY
1.3.6.1.4.1.9303.4.3.1.3
downloadServer
OBJECT-TYPE
The address of the server that contains the file to be loaded. This may take the form of an IP address or FQDN.
1.3.6.1.4.1.9303.4.3.1.3.1OCTET STRING (SIZE(0..32))read-writecurrent
downloadFile
OBJECT-TYPE
The file name to be downloaded from the download server or a URL to be downloaded via http. This value is set to the zero length string when no file name has been specified.
1.3.6.1.4.1.9303.4.3.1.3.2OCTET STRING (SIZE(0..80))read-writecurrent
downloadAction
OBJECT-TYPE
When this object is set to startDownload(2), the system will attempt to connect to the server specified in downloadServer (or the host part of downloadFile if a URL has been specified there), using the method defined in downloadMethod. If the file is found and verified, it will be downloaded to the device and stored. When the download process is completed, the device will restart the newly loaded application. When the device is not downloading, this object will have a value of notDownloading(1).
1.3.6.1.4.1.9303.4.3.1.3.3INTEGER {notDownloading(1), startDownload(2)}read-writecurrent
downloadMethod
OBJECT-TYPE
Defines the method to be used for the file download. This may be a specific protocol, or auto(3) which will cycle through the available methods to find one which works.
1.3.6.1.4.1.9303.4.3.1.3.4INTEGER {tftp(1), http(2), auto(3)}read-writecurrent
downloadRetryCount
OBJECT-TYPE
Controls the number of attempts which will be made to perform a download before terminating the download attempt.
1.3.6.1.4.1.9303.4.3.1.3.5Integer32 (1..10)read-writecurrent
downloadResultCode
OBJECT-TYPE
This object returns the status of the last download procedure. If no downloads have occurred, none(0) is returned, or if there is currently a download in progress, inProgress(1) is returned.
1.3.6.1.4.1.9303.4.3.1.3.6INTEGER {none(0), inProgress(1), success(2), failureHostNotFound(3), failureFileNotFound(4), failureFileIncorrectSize(5), failureFileVerifyFailure(6), failureFileIncompatible(7), failureUnknownError(8)}read-onlycurrent
downloadResultNotify
OBJECT-TYPE
Setting the object to always(2) cause the system to send downloadResultCodeTrap after every download no matter the result. Setting the object to onlyErrors(3) cause the system to send downloadResultCodeTrap when an error occurs during the download. Setting the object to silent(1) cause the system to not send any downloadResultNotify notifications.
1.3.6.1.4.1.9303.4.3.1.3.7INTEGER {silent(1), always(2), onError(3)}read-writecurrent
hostConfig
OBJECT-IDENTITY
1.3.6.1.4.1.9303.4.3.1.4
hostIfMax
OBJECT-TYPE
The maximum numbers of entries (and layer 3 interfaces) in the hostIfTable.
1.3.6.1.4.1.9303.4.3.1.4.1Integer32read-onlycurrent
hostIfDefined
OBJECT-TYPE
The current number of defined host interfaces, i.e. the number of entries in the hostIfTable.
1.3.6.1.4.1.9303.4.3.1.4.2Integer32read-onlycurrent
hostIfTable
OBJECT-TYPE
A table holding a list of interfaces.
1.3.6.1.4.1.9303.4.3.1.4.3not-accessiblecurrent
hostIfEntry
OBJECT-TYPE
One row of the table.
1.3.6.1.4.1.9303.4.3.1.4.3.1not-accessiblecurrent
hostIfIndex
OBJECT-TYPE
A unique index for this IP interface entry.
1.3.6.1.4.1.9303.4.3.1.4.3.1.1Integer32 (1..4)read-onlycurrent
hostIfMode
OBJECT-TYPE
The operational mode of the interface, e.g. DHCP, PPPoE.
1.3.6.1.4.1.9303.4.3.1.4.3.1.2INTEGER {dhcp(1), static(2), pppoe(3), pppoeFixed(4)}read-writecurrent
hostIfHostName
OBJECT-TYPE
The name of the host interface. If the DHCP client is enabled this object reports the host name from the DHCP negotiation.
1.3.6.1.4.1.9303.4.3.1.4.3.1.3OCTET STRING (SIZE(0..32))read-writecurrent
hostIfAddress
OBJECT-TYPE
The IP address for this interface entry.
1.3.6.1.4.1.9303.4.3.1.4.3.1.4IpAddressread-createcurrent
hostIfSubnetMask
OBJECT-TYPE
The subnet mask for this interface entry.
1.3.6.1.4.1.9303.4.3.1.4.3.1.5IpAddressread-writecurrent
hostIfDefaultRouter
OBJECT-TYPE
The default router for this interface entry.
1.3.6.1.4.1.9303.4.3.1.4.3.1.6IpAddressread-writecurrent
hostIfDomainName
OBJECT-TYPE
The name of the domain name. If the DHCP client is enabled this object reports the domain name from the DHCP negotiation.
1.3.6.1.4.1.9303.4.3.1.4.3.1.7OCTET STRING (SIZE(0..32))read-writecurrent
hostIfDnsServer1
OBJECT-TYPE
The primary DNS server for this interface entry.
1.3.6.1.4.1.9303.4.3.1.4.3.1.8IpAddressread-writecurrent
hostIfDnsServer2
OBJECT-TYPE
The secondary DNS server for this interface entry.
1.3.6.1.4.1.9303.4.3.1.4.3.1.9IpAddressread-writecurrent
hostIfDhcpClientID
OBJECT-TYPE
Setting this object causes the system to use a proprietary client identifier to identify itself to the DHCP server. By default the productMacAddress value of the device is used. This object thus allows the definition of the DHCP option 61 value.
1.3.6.1.4.1.9303.4.3.1.4.3.1.10OCTET STRING (SIZE(0..32))read-writecurrent
hostIfDhcpVendorClassID
OBJECT-TYPE
Setting this object causes the system to use the defined value as the DHCP vendor identifier in communication with the DHCP server. By default the value used is of the form 'drg-$productName$-$productSwImageRev$'. This object thus allows the definition of the DHCP option 60 value.
1.3.6.1.4.1.9303.4.3.1.4.3.1.11OCTET STRING (SIZE(0..48))read-writecurrent
hostIfDiffservCodePoint
OBJECT-TYPE
Defines the IP DSCP value used by default for this interface.
1.3.6.1.4.1.9303.4.3.1.4.3.1.12Integer32 (0..63)read-writecurrent
hostIfVlan
OBJECT-TYPE
Values 1..4094 define the default IEEE802.1Q VLAN tag used by this interface. By convention, this is used as the management VLAN when VLANs are enabled on this interface. The value 0 disables the use of management VLANs on this interface.
1.3.6.1.4.1.9303.4.3.1.4.3.1.13Integer32 (0..4094)read-writecurrent
hostIfVlanPriority
OBJECT-TYPE
Defines the default IEEE802.1p priority tag used by this interface. By convention, this is used as the management priority when VLANs are enabled on this interface.
1.3.6.1.4.1.9303.4.3.1.4.3.1.14Integer32 (0..7)read-writecurrent
hostIfSecurePing
OBJECT-TYPE
Setting this object to enabled(1) causes the device to silently drop ICMP echo (ping) requests. This is a simple way to cloak the presence of a device from ping sweeps.
1.3.6.1.4.1.9303.4.3.1.4.3.1.15INTEGER {enabled(1), disabled(2)}read-writecurrent
snmpConfig
OBJECT-IDENTITY
1.3.6.1.4.1.9303.4.3.1.7
snmpTrapDestHostsMax
OBJECT-TYPE
The maximum number of trap hosts which may be defined
1.3.6.1.4.1.9303.4.3.1.7.1Integer32read-onlycurrent
snmpTrapDestHostsDefined
OBJECT-TYPE
Current number of configured trap destinations.
1.3.6.1.4.1.9303.4.3.1.7.2Integer32read-onlycurrent
snmpTrapDestinationTable
OBJECT-TYPE
A table of transport addresses to be used in the generation of SNMP messages.
1.3.6.1.4.1.9303.4.3.1.7.3not-accessiblecurrent
snmpTrapDestinationEntry
OBJECT-TYPE
A transport address to be used in the generation of SNMP operations. Entries in the trapDestinationTable are created and deleted using the snmpTrapDestRowStatus object.
1.3.6.1.4.1.9303.4.3.1.7.3.1not-accessiblecurrent
snmpTrapDestIndex
OBJECT-TYPE
The locally arbitrary, but unique identifier associated with this trapDestinationEntry.
1.3.6.1.4.1.9303.4.3.1.7.3.1.1Integer32 (1..6)read-createcurrent
snmpTrapDestName
OBJECT-TYPE
This object contains a human readable name for the trap destination.
1.3.6.1.4.1.9303.4.3.1.7.3.1.2OCTET STRING (SIZE(0..32))read-createcurrent
snmpTrapDestAddress
OBJECT-TYPE
This object contains the address of the trap destination.
1.3.6.1.4.1.9303.4.3.1.7.3.1.3IpAddressread-createcurrent
snmpTrapDestTagList
OBJECT-TYPE
This object contains a list of tag values which are used to select target addresses for a particular operation.
1.3.6.1.4.1.9303.4.3.1.7.3.1.4OCTET STRING (SIZE(0..16))read-createcurrent
snmpTrapDestRowStatus
OBJECT-TYPE
The status of this conceptual row. To create a row in this table, a manager must set this object to either createAndGo(4) or createAndWait(5). Until instances of all corresponding columns are appropriately configured, the value of the corresponding instance of the trapDestRowStatus column is 'notReady'.
1.3.6.1.4.1.9303.4.3.1.7.3.1.5RowStatusread-createcurrent
snmpReadCommunityName
OBJECT-TYPE
The read community string for the device.
1.3.6.1.4.1.9303.4.3.1.7.4OCTET STRING (SIZE(1..16))read-writecurrent
snmpWriteCommunityName
OBJECT-TYPE
The write community string for the device.
1.3.6.1.4.1.9303.4.3.1.7.5OCTET STRING (SIZE(1..16))read-writecurrent
snmpTrapCommunityName
OBJECT-TYPE
The notification community string for the device.
1.3.6.1.4.1.9303.4.3.1.7.6OCTET STRING (SIZE(1..16))read-writecurrent
snmpDiffservCodePoint
OBJECT-TYPE
Defines the IP DSCP value used by the SNMP agent.
1.3.6.1.4.1.9303.4.3.1.7.7Integer32 (0..63)read-writecurrent
snmpAtomicSet
OBJECT-TYPE
Complex operations involving numerous set commands can cause problems due to the lack of atomic operation by the network management system. This object may be used to ensure that all required changes for this MIB are made in a single atomic operation. This can be achieved by setting this object to stage(2), then setting all required objects, and then setting this object to apply(3). The object value will return to idle(1) once the atomic set operation has been completed.
1.3.6.1.4.1.9303.4.3.1.7.8INTEGER {idle(1), stage(2), apply(3)}read-writecurrent
vlanConfig
OBJECT-IDENTITY
1.3.6.1.4.1.9303.4.3.1.8
vlanBase
OBJECT-IDENTITY
1.3.6.1.4.1.9303.4.3.1.8.1
vlanVersionNumber
OBJECT-TYPE
The version number of IEEE802.1Q that this device supports.
1.3.6.1.4.1.9303.4.3.1.8.1.1INTEGER {version1(1), version2(2)}read-onlycurrent
vlanMaxVlanId
OBJECT-TYPE
The maximum IEEE802.1Q VLAN ID that this device supports.
1.3.6.1.4.1.9303.4.3.1.8.1.2Integer32 (1..4094)read-onlycurrent
vlanMaxSupportedVlans
OBJECT-TYPE
The maximum number of IEEE802.1Q VLANs that this device supports.
1.3.6.1.4.1.9303.4.3.1.8.1.3Unsigned32read-onlycurrent
vlanNumVlans
OBJECT-TYPE
The current number of IEEE802.1Q VLANs that are configured in this device.
1.3.6.1.4.1.9303.4.3.1.8.1.4Unsigned32read-onlycurrent
vlanTp
OBJECT-IDENTITY
1.3.6.1.4.1.9303.4.3.1.8.2
vlanFdbTable
OBJECT-TYPE
A table that contains configuration and control information for each Filtering Database currently operating on this device. Entries in this table appear automatically when VLANs are assigned FDB IDs in the vlanVlanCurrentTable.
1.3.6.1.4.1.9303.4.3.1.8.2.1not-accessiblecurrent
vlanFdbEntry
OBJECT-TYPE
Information about a specific Filtering Database.
1.3.6.1.4.1.9303.4.3.1.8.2.1.1not-accessiblecurrent
vlanFdbId
OBJECT-TYPE
The identity of this Filtering Database.
1.3.6.1.4.1.9303.4.3.1.8.2.1.1.1Unsigned32not-accessiblecurrent
vlanFdbDynamicCount
OBJECT-TYPE
The current number of dynamic entries in this Filtering Database.
1.3.6.1.4.1.9303.4.3.1.8.2.1.1.2Counter32read-onlycurrent
vlanTpFdbTable
OBJECT-TYPE
A table that contains information about unicast entries for which the device has forwarding and/or filtering information. This information is used by the transparent bridging function in determining how to propagate a received frame.
1.3.6.1.4.1.9303.4.3.1.8.2.2not-accessiblecurrent
vlanTpFdbEntry
OBJECT-TYPE
Information about a specific unicast MAC address for which the device has some forwarding and/or filtering information.
1.3.6.1.4.1.9303.4.3.1.8.2.2.1not-accessiblecurrent
vlanTpFdbAddress
OBJECT-TYPE
A unicast MAC address for which the device has forwarding and/or filtering information.
1.3.6.1.4.1.9303.4.3.1.8.2.2.1.1MacAddressnot-accessiblecurrent
vlanTpFdbPort
OBJECT-TYPE
Either the value '0', or the port number of the port on which a frame having a source address equal to the value of the corresponding instance of vlanTpFdbAddress has been seen. A value of '0' indicates that the port number has not been learned but that the device does have some forwarding/filtering information about this address (e.g. in the vlanStaticUnicastTable). Implementors are encouraged to assign the port value to this object whenever it is learned even for addresses for which the corresponding value of vlanTpFdbStatus is not learned(3).
1.3.6.1.4.1.9303.4.3.1.8.2.2.1.2Integer32 (0..65535)read-onlycurrent
vlanTpFdbStatus
OBJECT-TYPE
The status of this entry. The meanings of the values are: other(1) - none of the following. This may include the case where some other MIB object (not the corresponding instance of vlanTpFdbPort, nor an entry in the vlanStaticUnicastTable) is being used to determine if and how frames addressed to the value of the corresponding instance of vlanTpFdbAddress are being forwarded. invalid(2) - this entry is no longer valid (e.g., it was learned but has since aged out), but has not yet been flushed from the table. learned(3) - the value of the corresponding instance of vlanTpFdbPort was learned and is being used. self(4) - the value of the corresponding instance of vlanTpFdbAddress represents one of the device's addresses. The corresponding instance of vlanTpFdbPort indicates which of the device's ports has this address. mgmt(5) - the value of the corresponding instance of vlanTpFdbAddress is also the value of an existing instance of vlanStaticAddress.
1.3.6.1.4.1.9303.4.3.1.8.2.2.1.3INTEGER {other(1), invalid(2), learned(3), self(4), mgmt(5)}read-onlycurrent
vlanStatic
OBJECT-IDENTITY
1.3.6.1.4.1.9303.4.3.1.8.3
vlanStaticTable
OBJECT-TYPE
A table containing static configuration information for each VLAN configured on the device. All entries are permanent and will be restored after the device is reset.
1.3.6.1.4.1.9303.4.3.1.8.3.1not-accessiblecurrent
vlanStaticEntry
OBJECT-TYPE
Static information for a VLAN configured in the device.
1.3.6.1.4.1.9303.4.3.1.8.3.1.1not-accessiblecurrent
vlanStaticIndex
OBJECT-TYPE
The locally arbitrary, but unique identifier associated with this vlanStaticEntry.
1.3.6.1.4.1.9303.4.3.1.8.3.1.1.1Integer32 (1..16)read-createcurrent
vlanStaticName
OBJECT-TYPE
An administratively assigned string, which may be used to identify the VLAN
1.3.6.1.4.1.9303.4.3.1.8.3.1.1.2OCTET STRING (SIZE(0..16))read-writecurrent
vlanStaticVlanId
OBJECT-TYPE
The VLAN identifier associated with this VLAN entry
1.3.6.1.4.1.9303.4.3.1.8.3.1.1.3Integer32 (1..4094)read-writecurrent
vlanStaticPriority
OBJECT-TYPE
The IEEE802.1p priority value associated with this VLAN entry - this information may be used for policing priority where supported
1.3.6.1.4.1.9303.4.3.1.8.3.1.1.4Integer32 (0..7)read-writecurrent
vlanStaticEgressPorts
OBJECT-TYPE
The set of ports which are permanently assigned to the egress list for this VLAN by management. The default value of this object is a string of zeros of appropriate length, indicating not fixed.
1.3.6.1.4.1.9303.4.3.1.8.3.1.1.5PortListread-writecurrent
vlanStaticUntaggedPorts
OBJECT-TYPE
Describes the set of ports which should transmit egress packets for this VLAN untagged. If a device agent cannot support the set of ports being set then it will reject the set operation with an error. An example might be if a manager attempts to set more than one VLAN to be untagged on egress where the device does not support this IEEE 802.1Q option.
1.3.6.1.4.1.9303.4.3.1.8.3.1.1.6PortListread-writecurrent
vlanStaticUnmodifiedPorts
OBJECT-TYPE
Describes the set of ports which should transmit egress packets for this VLAN unmodified. If a device agent cannot support the set of ports being set then it will reject the set operation with an error. Note that if this behaviour is supported and the bit is set for a port, the value of the same bit in vlanStaticUntaggedPorts is ignored.
1.3.6.1.4.1.9303.4.3.1.8.3.1.1.7PortListread-writecurrent
vlanStaticRowStatus
OBJECT-TYPE
This object indicates the status of this entry.
1.3.6.1.4.1.9303.4.3.1.8.3.1.1.8RowStatusread-createcurrent
drgConformance
OBJECT-IDENTITY
1.3.6.1.4.1.9303.4.3.2
drgGroups
OBJECT-IDENTITY
1.3.6.1.4.1.9303.4.3.2.1
drgCompliance
OBJECT-IDENTITY
1.3.6.1.4.1.9303.4.3.2.2
drgCompatibility
OBJECT-IDENTITY
1.3.6.1.4.1.9303.4.3.2.3

Notifications

NameOIDStatus
notifyRestart
NOTIFICATION-TYPE
After booting the system sends this notification repeatedly with an increasing time delay until a valid management station reads or writes an object.
1.3.6.1.4.1.9303.4.3.0.1current
notifyDownloadResult
NOTIFICATION-TYPE
When the device has downloaded a new firmware image or configuration file, the device sends this notification to inform the management system of the result.
1.3.6.1.4.1.9303.4.3.0.2current
notifyConfigSaveResult
NOTIFICATION-TYPE
When a save event occurs, the device sends this notification to inform the management system of the result.
1.3.6.1.4.1.9303.4.3.0.3current