Description

MIB for the PacketFlux Standby Power Controller

Contact

custsvc@packetflux.com http://www.packetflux.com

Imports

FromSymbols
PACKETFLUX-SMIpacketfluxMgmt
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIGauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

PACKETFLUX-SMI
PACKETFLUX-STANDBYPOWER
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
powercontrollerstate
OBJECT-TYPE
The status of the standby power controller.
1.3.6.1.4.1.32050.2.2.1INTEGER {onprimarypower(1), startingstandby(2), transferringtostandby(3), onstandbypower(4), transferringtoprimary(5)}read-onlycurrent
transferswitchstate
OBJECT-TYPE
The current state in the transfer sequence.
1.3.6.1.4.1.32050.2.2.2INTEGER {primary(1), transfertostandby1(2), transfertostandby2(3), transfertostandby3(4), standby(5), transfertoprimary1(6), transfertoprimary2(7), transfertoprimary3(8)}read-onlycurrent
standbypowerstate
OBJECT-TYPE
The current state in the standby power sequence.
1.3.6.1.4.1.32050.2.2.3INTEGER {stopped(1), prepare1(2), prepare2(3), prepare3(4), startup1(5), startup2(6), startup3(7), checkrun(8), reprepare1(9), reprepare2(10), reprepare3(11), warmup1(12), warmup2(13), warmup3(14), verifyrun(15), running(16), cooldown1(17), cooldown2(18), cooldown3(19), shutdown1(20), shutdown2(21), shutdown3(22), verifystopped(23), postshutdown1(24), postshutdown2(25), postshutdown3(26)}read-onlycurrent
ac1voltage
OBJECT-TYPE
The voltage of the AC input AC1 in 1/10ths of a volt.
1.3.6.1.4.1.32050.2.2.4Gauge32read-onlycurrent
ac1frequency
OBJECT-TYPE
The frequency of the AC input AC1 in 1/100ths of a Hertz.
1.3.6.1.4.1.32050.2.2.5Gauge32read-onlycurrent
ac2voltage
OBJECT-TYPE
The voltage of the AC input AC2 in 1/10ths of a volt.
1.3.6.1.4.1.32050.2.2.6Gauge32read-onlycurrent
ac2frequency
OBJECT-TYPE
The frequency of the AC input AC2 in 1/100ths of a Hertz.
1.3.6.1.4.1.32050.2.2.7Gauge32read-onlycurrent
mtr1voltage
OBJECT-TYPE
The voltage of the DC input Mtr1 in 1/10ths of a volt.
1.3.6.1.4.1.32050.2.2.8Gauge32read-onlycurrent
mtr2voltage
OBJECT-TYPE
The voltage of the DC input Mtr2 in 1/10ths of a volt.
1.3.6.1.4.1.32050.2.2.9Gauge32read-onlycurrent
pwr1voltage
OBJECT-TYPE
The voltage of the DC input Pwr3 in 1/10ths of a volt.
1.3.6.1.4.1.32050.2.2.10Gauge32read-onlycurrent
pwr2voltage
OBJECT-TYPE
The voltage of the DC input Pwr2 in 1/10ths of a volt.
1.3.6.1.4.1.32050.2.2.11Gauge32read-onlycurrent
shuntvoltage
OBJECT-TYPE
The voltage of the DC input Shunt in 1/10ths of a millivolt. Can be negative.
1.3.6.1.4.1.32050.2.2.12Integer32read-onlycurrent
temperature
OBJECT-TYPE
The temperature of the onboard temperature sensor in 1/10ths of a degree centigrade.
1.3.6.1.4.1.32050.2.2.13Gauge32read-onlycurrent
recentunsuccessfulstarts
OBJECT-TYPE
The number of times the standby power source was not successfully started. This counter resets upon a successful start. It can also be reset via the web interface or by writing 0 to this object.
1.3.6.1.4.1.32050.2.2.14Integer32read-writecurrent
totalunsuccessfulstarts
OBJECT-TYPE
The number of times the standby power source was not successfully started. This counter DOES NOT reset upon a successful start. It can be reset via the web interface or by writing 0 to this object.
1.3.6.1.4.1.32050.2.2.15Integer32read-writecurrent
recentstalls
OBJECT-TYPE
The number of times the standby power source has stalled. This counter resets upon a clean shutdown. It can also be reset via the web interface or by writing 0 to this object.
1.3.6.1.4.1.32050.2.2.16Integer32read-writecurrent
totalstalls
OBJECT-TYPE
The number of times the standby power source has stalled. This counter DOES NOT reset upon a clean shutdown. It can be reset via the web interface or by writing 0 to this object.
1.3.6.1.4.1.32050.2.2.17Integer32read-writecurrent
numberofstarts
OBJECT-TYPE
The number of times the secondary power source has started. This counter increments when the standby sequence reaches the running state. This counter can be reset via the web interface or by writing 0 to this object.
1.3.6.1.4.1.32050.2.2.18Integer32read-writecurrent
numberoftransfers
OBJECT-TYPE
The number of times the power has transfered from primary to standby, or back. A complete transfer cycle from primary to standby and back to primary will increment this counter twice. This counter can be reset via the web interface or by writing 0 to this object.
1.3.6.1.4.1.32050.2.2.19Integer32read-writecurrent
currenttimeonprimary
OBJECT-TYPE
The amount of time the transfer switch has been in the primary state (position) since the most recent transfer to that state. This timer resets to zero when the transfer switch leaves the primary state (position). This timer can be reset via the web interface or by writing 0 to this object.
1.3.6.1.4.1.32050.2.2.20TimeTicksread-writecurrent
totaltimeonprimary
OBJECT-TYPE
The amount of time the transfer switch has been in the primary state (position) since power on or the last reset of this counter. This timer does not automatically reset. This timer can be reset via the web interface or by writing 0 to this object.
1.3.6.1.4.1.32050.2.2.21TimeTicksread-writecurrent
currenttimeonstandby
OBJECT-TYPE
The amount of time the transfer switch has been in the standby state (position) since the most recent transfer to that state. This timer resets to zero when the transfer switch leaves the primary state (position). This timer can be reset via the web interface or by writing 0 to this object.
1.3.6.1.4.1.32050.2.2.22TimeTicksread-writecurrent
totaltimeonstandby
OBJECT-TYPE
The amount of time the transfer switch has been in the standby state (position) since power on or the last reset of this counter. This timer does not automatically reset. This timer can be reset via the web interface or by writing 0 to this object.
1.3.6.1.4.1.32050.2.2.23TimeTicksread-writecurrent
currentstandbyruntime
OBJECT-TYPE
The amount of time the standby power source has been running during it's current run. This timer resets to zero when the standby power source shuts down. This timer can be reset via the web interface or by writing 0 to this object.
1.3.6.1.4.1.32050.2.2.24TimeTicksread-writecurrent
totalstandbyruntime
OBJECT-TYPE
The amount of time the standby power source has been running since power on or the last reset of this counter. This timer does not automatically reset. This timer can be reset via the web interface or by writing 0 to this object.
1.3.6.1.4.1.32050.2.2.25TimeTicksread-writecurrent
laststandbyrun
OBJECT-TYPE
The amount of time since the standby power source ran last. This timer resets upon start of the standby power source and starts timing upon shutdown of the standby power source. This timer can be reset via the web interface or by writing 0 to this object.
1.3.6.1.4.1.32050.2.2.26TimeTicksread-writecurrent
laststandbygracefulstop
OBJECT-TYPE
The amount of time since standby power source was gracefully shutdown. This timer resets and starts timing upon graceful shutdown of the standby power source. This timer can be reset via the web interface or by writing 0 to this object.
1.3.6.1.4.1.32050.2.2.27TimeTicksread-writecurrent
laststandbyunsuccessfulstart
OBJECT-TYPE
The amount of time since the last failed start of the standby power source . This timer resets and starts timing upon a unsuccessful start of the power source. This timer can be reset via the web interface or by writing 0 to this object.
1.3.6.1.4.1.32050.2.2.28TimeTicksread-writecurrent
laststandbyfailure
OBJECT-TYPE
The amount of time since the stall or failure while running of the standby power source . This timer resets and starts timing upon a stall/failure of the power source. This timer can be reset via the web interface or by writing 0 to this object.
1.3.6.1.4.1.32050.2.2.29TimeTicksread-writecurrent
switch1closed
OBJECT-TYPE
True(1) if the Switch 1 input is closed (shorted/on). False(2) if it is open.
1.3.6.1.4.1.32050.2.2.30TruthValueread-onlycurrent
switch2closed
OBJECT-TYPE
True(1) if the Switch 2 input is closed (shorted/on). False(2) if it is open.
1.3.6.1.4.1.32050.2.2.31TruthValueread-onlycurrent
switch3closed
OBJECT-TYPE
True(1) if the Switch 3 input is closed (shorted/on). False(2) if it is open.
1.3.6.1.4.1.32050.2.2.32TruthValueread-onlycurrent
switch4closed
OBJECT-TYPE
True(1) if the Switch 4 input is closed (shorted/on). False(2) if it is open.
1.3.6.1.4.1.32050.2.2.33TruthValueread-onlycurrent
switch5closed
OBJECT-TYPE
True(1) if the Switch 5 input is closed (shorted/on). False(2) if it is open.
1.3.6.1.4.1.32050.2.2.34TruthValueread-onlycurrent
enabled
OBJECT-TYPE
True(1) if the enable input is closed (shorted/on). False(2) if it is open.
1.3.6.1.4.1.32050.2.2.35TruthValueread-onlycurrent
relay1on
OBJECT-TYPE
True(1) if the Relay 1 ouput is on (C and NO connected). False(2) if it is off (C and NC connected).
1.3.6.1.4.1.32050.2.2.36TruthValueread-onlycurrent
relay2on
OBJECT-TYPE
True(1) if the Relay 2 ouput is on (C and NO connected). False(2) if it is off (C and NC connected).
1.3.6.1.4.1.32050.2.2.37TruthValueread-onlycurrent
relay3on
OBJECT-TYPE
True(1) if the Relay 3 ouput is on (C and NO connected). False(2) if it is off (C and NC connected).
1.3.6.1.4.1.32050.2.2.38TruthValueread-onlycurrent
relay4on
OBJECT-TYPE
True(1) if the Relay 4 ouput is on (C and NO connected). False(2) if it is off (C and NC connected).
1.3.6.1.4.1.32050.2.2.39TruthValueread-onlycurrent
relay5on
OBJECT-TYPE
True(1) if the Relay 5 output is on (C and NO connected). False(2) if it is off (C and NC connected).
1.3.6.1.4.1.32050.2.2.40TruthValueread-onlycurrent
relay6on
OBJECT-TYPE
True(1) if the Relay 6 output is on (C and NO connected). False(2) if it is off (C and NC connected).
1.3.6.1.4.1.32050.2.2.41TruthValueread-onlycurrent
relay7on
OBJECT-TYPE
True(1) if the Relay 7 output is on (C and NO connected). False(2) if it is off (C and NC connected).
1.3.6.1.4.1.32050.2.2.42TruthValueread-onlycurrent
ruleswitchstandby
OBJECT-TYPE
True(1) if the switch to standby rule is true. False(2) if it is not.
1.3.6.1.4.1.32050.2.2.43TruthValueread-onlycurrent
rulereturnprimary
OBJECT-TYPE
True(1) if the return to primary rule is true. False(2) if it is not.
1.3.6.1.4.1.32050.2.2.44TruthValueread-onlycurrent
rulestandbygood
OBJECT-TYPE
True(1) if the standby power good rule is true. False(2) if it is not.
1.3.6.1.4.1.32050.2.2.45TruthValueread-onlycurrent
rulestopstandby
OBJECT-TYPE
True(1) if the stop standby and consider it failed rule is true. False(2) if it is not.
1.3.6.1.4.1.32050.2.2.46TruthValueread-onlycurrent
ruleexercisestandby
OBJECT-TYPE
True(1) if the exercise standby without transfer rule is true. False(2) if it is not.
1.3.6.1.4.1.32050.2.2.47TruthValueread-onlycurrent
webcontrol1
OBJECT-TYPE
True(1) if the webcontrol 1 virtual toggle switch is in the on position. False(2) if it is not. This value can be written to affect the position of the toggle switch.
1.3.6.1.4.1.32050.2.2.48TruthValueread-writecurrent
webcontrol2
OBJECT-TYPE
True(1) if the webcontrol 2 virtual toggle switch is in the on position. False(2) if it is not. This value can be written to affect the position of the toggle switch.
1.3.6.1.4.1.32050.2.2.49TruthValueread-writecurrent
webcontrol3
OBJECT-TYPE
True(1) if the webcontrol 3 virtual toggle switch is in the on position. False(2) if it is not. This value can be written to affect the position of the toggle switch.
1.3.6.1.4.1.32050.2.2.50TruthValueread-writecurrent
webcontrol4
OBJECT-TYPE
True(1) if the webcontrol 4 virtual toggle switch is in the on position. False(2) if it is not. This value can be written to affect the position of the toggle switch.
1.3.6.1.4.1.32050.2.2.51TruthValueread-writecurrent
webcontrol5
OBJECT-TYPE
True(1) if the webcontrol 5 virtual toggle switch is in the on position. False(2) if it is not. This value can be written to affect the position of the toggle switch.
1.3.6.1.4.1.32050.2.2.52TruthValueread-writecurrent
webcontrol6
OBJECT-TYPE
True(1) if the webcontrol 6 virtual toggle switch is in the on position. False(2) if it is not. This value can be written to affect the position of the toggle switch.
1.3.6.1.4.1.32050.2.2.53TruthValueread-writecurrent
webcontrol7
OBJECT-TYPE
True(1) if the webcontrol 7 virtual toggle switch is in the on position. False(2) if it is not. This value can be written to affect the position of the toggle switch.
1.3.6.1.4.1.32050.2.2.54TruthValueread-writecurrent
webcontrol8
OBJECT-TYPE
True(1) if the webcontrol 8 virtual toggle switch is in the on position. False(2) if it is not. This value can be written to affect the position of the toggle switch.
1.3.6.1.4.1.32050.2.2.55TruthValueread-writecurrent
standbypowerConformance
OBJECT-IDENTITY
1.3.6.1.4.1.32050.2.2.256
standbypowerGroups
OBJECT-IDENTITY
1.3.6.1.4.1.32050.2.2.256.1

Conformance

NameOIDStatus
packetfluxStandbypowerAllObjects
OBJECT-GROUP
This automatically created object group contains all those objects that do not belong to any other OBJECT-GROUP
1.3.6.1.4.1.32050.2.2.256.1.1current