OPT-IF-MIB
- Registered at
- 1.3.6.1.2.1.10.133
- Last updated
- 2003-08-13 00:00
- Organization
- IETF AToM MIB Working Group
- Revisions
- 2003-08-13 00:00
- Namespace
- standard
- Source file
OPT-IF-MIB- Digest
sha256:03054f8c7605311b078042a0fc94282fed56d2105822844515d464d550610654
Description
The MIB module to describe pre-OTN and OTN interfaces. Copyright (C) The Internet Society (2003). This version of this MIB module is part of RFC 3591; see the RFC itself for full legal notices.
Contact
WG charter: http://www.ietf.org/html.charters/atommib-charter.html Mailing Lists: General Discussion: atommib@research.telcordia.com To Subscribe: atommib-request@research.telcordia.com Editor: Hing-Kam Lam Postal: Lucent Technologies, Room 4C-616 101 Crawfords Corner Road Holmdel, NJ 07733 Tel: +1 732 949 8338 Email: hklam@lucent.com
Imports
| From | Symbols |
|---|---|
| IF-MIB | ifIndex |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso, transmission |
| SNMPv2-TC | DisplayString, RowPointer, RowStatus, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB IF-MIB OPT-IF-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| OptIfAcTI TEXTUAL-CONVENTION The trace identifier (TI) accepted at the receiver. | current | |||
| OptIfBitRateK TEXTUAL-CONVENTION Indicates the index 'k' that is used to represent a supported bit rate and the different versions of OPUk, ODUk and OTUk. Allowed values of k are defined in ITU-T G.709. Currently allowed values in G.709 are: k=1 represents an approximate bit rate of 2.5 Gbit/s, k=2 represents an approximate bit rate of 10 Gbit/s, k=3 represents an approximate bit rate of 40 Gbit/s. | current | |||
| OptIfDEGM TEXTUAL-CONVENTION Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if OptIfDEGM consecutive bad PM Seconds are detected. | current | |||
| OptIfDEGThr TEXTUAL-CONVENTION Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to OptIfDEGThr. | current | |||
| OptIfDirectionality TEXTUAL-CONVENTION Indicates the directionality of an entity. | current | |||
| OptIfExDAPI TEXTUAL-CONVENTION The Destination Access Point Identifier (DAPI) expected by the receiver. | current | |||
| OptIfExSAPI TEXTUAL-CONVENTION The Source Access Point Identifier (SAPI) expected by the receiver. | current | |||
| OptIfIntervalNumber TEXTUAL-CONVENTION Uniquely identifies a 15-minute interval. The interval identified by 1 is the most recently completed interval, and the interval identified by n is the interval immediately preceding the one identified by n-1. | current | |||
| OptIfSinkOrSource TEXTUAL-CONVENTION Indicates the directionality of an entity that is allowed only to be a source or sink. | current | |||
| OptIfTIMDetMode TEXTUAL-CONVENTION Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. | current | |||
| OptIfTxTI TEXTUAL-CONVENTION The trace identifier (TI) transmitted. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| optIfObjects OBJECT-IDENTITY | 1.3.6.1.2.1.10.133.1 | |||
| optIfOTMn OBJECT-IDENTITY | 1.3.6.1.2.1.10.133.1.1 | |||
| optIfOTMnTable OBJECT-TYPE A table of OTMn structure information. | 1.3.6.1.2.1.10.133.1.1.1 | not-accessible | current | |
| optIfOTMnEntry OBJECT-TYPE A conceptual row that contains the OTMn structure information of an optical interface. | 1.3.6.1.2.1.10.133.1.1.1.1 | not-accessible | current | |
| optIfOTMnOrder OBJECT-TYPE This object indicates the order of the OTM, which represents the maximum number of wavelengths that can be supported at the bit rate(s) supported on the interface. | 1.3.6.1.2.1.10.133.1.1.1.1.1 | Unsigned32 (1..900) | read-only | current |
| optIfOTMnReduced OBJECT-TYPE This object indicates whether a reduced or full functionality is supported at the interface. A value of true means reduced. A value of false means full. | 1.3.6.1.2.1.10.133.1.1.1.1.2 | TruthValue | read-only | current |
| optIfOTMnBitRates OBJECT-TYPE This attribute is a bit map representing the bit rate or set of bit rates supported on the interface. The meaning of each bit position is as follows: bitRateK1(0) is set if the 2.5 Gbit/s rate is supported bitRateK2(1) is set if the 10 Gbit/s rate is supported bitRateK3(2) is set if the 40 Gbit/s rate is supported Note that each bit position corresponds to one possible value of the type OptIfBitRateK. The default value of this attribute is system specific. | 1.3.6.1.2.1.10.133.1.1.1.1.3 | Bits {bitRateK1(0), bitRateK2(1), bitRateK3(2)} | read-only | current |
| optIfOTMnInterfaceType OBJECT-TYPE This object identifies the type of interface. The value of this attribute will affect the behavior of the OTM with respect to presence/absence of OTM Overhead Signal (OOS) processing and TCM activation. For an IrDI interface, there is no OOS processing and TCM activation is limited to n levels as specified by a TCM level threshold. This object contains two fields that are separated by whitespace. The possible values are: field 1: one of the 4-character ASCII strings 'IrDI' or 'IaDI' field 2: free-form text consisting of printable UTF-8 encoded characters Note that field 2 is optional. If it is not present then there is no requirement for trailing whitespace after field 1. The default values are as follows: field 1: 'IaDI' field 2: an empty string. | 1.3.6.1.2.1.10.133.1.1.1.1.4 | SnmpAdminString | read-only | current |
| optIfOTMnTcmMax OBJECT-TYPE This object identifies the maximum number of TCM levels allowed for any Optical Channel contained in this OTM. A new TCM activation will be rejected if the requested level is greater than the threshold. If InterfaceType object specifies a type of 'IaDI' for this OTM, then this attribute is irrelevant. Possible values: unsigned integers in the range from 0 to 6 inclusive. Default value: 3. | 1.3.6.1.2.1.10.133.1.1.1.1.5 | Unsigned32 (0..6) | read-write | current |
| optIfOTMnOpticalReach OBJECT-TYPE This object indicates the length the optical signal may travel before requiring termination or regeneration. The meaning of the enumeration are: intraOffice(1) - intra-office (as defined in ITU-T G.957) shortHaul(2) - short haul (as defined in ITU-T G.957) longHaul(3) - long haul (as defined in ITU-T G.957) veryLongHaul(4) - very long haul (as defined in ITU-T G.691) ultraLongHaul(5)- ultra long haul (as defined in ITU-T G.691) | 1.3.6.1.2.1.10.133.1.1.1.1.6 | INTEGER {intraOffice(1), shortHaul(2), longHaul(3), veryLongHaul(4), ultraLongHaul(5)} | read-only | current |
| optIfPerfMon OBJECT-IDENTITY | 1.3.6.1.2.1.10.133.1.2 | |||
| optIfPerfMonIntervalTable OBJECT-TYPE A table of 15-minute performance monitoring interval information. | 1.3.6.1.2.1.10.133.1.2.1 | not-accessible | current | |
| optIfPerfMonIntervalEntry OBJECT-TYPE A conceptual row that contains 15-minute performance monitoring interval information of an interface. | 1.3.6.1.2.1.10.133.1.2.1.1 | not-accessible | current | |
| optIfPerfMonCurrentTimeElapsed OBJECT-TYPE Number of seconds elapsed in the current 15-minute performance monitoring interval. If, for some reason, such as an adjustment in the NE's time-of-day clock, the number of seconds elapsed exceeds the maximum value, then the maximum value will be returned. | 1.3.6.1.2.1.10.133.1.2.1.1.1 | Gauge32 (0..900) | read-only | current |
| optIfPerfMonCurDayTimeElapsed OBJECT-TYPE Number of seconds elapsed in the current 24-hour interval performance monitoring period. If, for some reason, such as an adjustment in the NE's time-of-day clock, the number of seconds elapsed exceeds the maximum value, then the maximum value will be returned. | 1.3.6.1.2.1.10.133.1.2.1.1.2 | Gauge32 (0..86400) | read-only | current |
| optIfPerfMonIntervalNumIntervals OBJECT-TYPE The number of 15-minute intervals for which performance monitoring data is available. The number is the same for all the associated sub layers of the interface. An optical interface must be capable of supporting at least n intervals, where n is defined as follows: The minimum value of n is 4. The default of n is 32. The maximum value of n is 96. The value of this object will be n unless performance monitoring was (re-)started for the interface within the last (n*15) minutes, in which case the value will be the number of complete 15-minute intervals since measurement was (re-)started. | 1.3.6.1.2.1.10.133.1.2.1.1.3 | Unsigned32 (0..96) | read-only | current |
| optIfPerfMonIntervalNumInvalidIntervals OBJECT-TYPE The number of intervals in the range from 0 to optIfPerfMonIntervalNumIntervals for which no performance monitoring data is available and/or the data is invalid. | 1.3.6.1.2.1.10.133.1.2.1.1.4 | Unsigned32 (0..96) | read-only | current |
| optIfOTSn OBJECT-IDENTITY | 1.3.6.1.2.1.10.133.1.3 | |||
| optIfOTSnConfigTable OBJECT-TYPE A table of OTSn configuration information. | 1.3.6.1.2.1.10.133.1.3.1 | not-accessible | current | |
| optIfOTSnConfigEntry OBJECT-TYPE A conceptual row that contains OTSn configuration information of an interface. | 1.3.6.1.2.1.10.133.1.3.1.1 | not-accessible | current | |
| optIfOTSnDirectionality OBJECT-TYPE Indicates the directionality of the entity. | 1.3.6.1.2.1.10.133.1.3.1.1.1 | OptIfDirectionality | read-only | current |
| optIfOTSnAprStatus OBJECT-TYPE This attribute indicates the status of the Automatic Power Reduction (APR) function of the entity. Valid values are 'on' and 'off'. | 1.3.6.1.2.1.10.133.1.3.1.1.2 | SnmpAdminString | read-only | current |
| optIfOTSnAprControl OBJECT-TYPE This object is a UTF-8 encoded string that specifies Automatic Power Reduction (APR) control actions requested of this entity (when written) and that returns the current APR control state of this entity (when read). The values are implementation-defined. Any implementation that instantiates this object must document the set of values that it allows to be written, the set of values that it will return, and what each of those values means. | 1.3.6.1.2.1.10.133.1.3.1.1.3 | SnmpAdminString | read-write | current |
| optIfOTSnTraceIdentifierTransmitted OBJECT-TYPE The trace identifier transmitted. This object is applicable when optIfOTSnDirectionality has the value source(2) or bidirectional(3). This object does not apply to reduced-capability systems (i.e., those for which optIfOTMnReduced has the value true(1)) or at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1 has the value 'IrDI'). If no value is ever set by a management entity for the object optIfOTSnTraceIdentifierTransmitted, system-specific default value will be used. Any implementation that instantiates this object must document the system-specific default value or how it is derived. | 1.3.6.1.2.1.10.133.1.3.1.1.4 | OptIfTxTI | read-write | current |
| optIfOTSnDAPIExpected OBJECT-TYPE The DAPI expected by the receiver. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(3). It has no effect if optIfOTSnTIMDetMode has the value off(1) or sapi(3). This object does not apply to reduced-capability systems (i.e., those for which optIfOTMnReduced has the value true(1)) or at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1 has the value 'IrDI'). | 1.3.6.1.2.1.10.133.1.3.1.1.5 | OptIfExDAPI | read-write | current |
| optIfOTSnSAPIExpected OBJECT-TYPE The SAPI expected by the receiver. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(3). It has no effect if optIfOTSnTIMDetMode has the value off(1) or dapi(2). This object does not apply to reduced-capability systems (i.e., those for which optIfOTMnReduced has the value true(1)) or at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1 has the value 'IrDI'). | 1.3.6.1.2.1.10.133.1.3.1.1.6 | OptIfExSAPI | read-write | current |
| optIfOTSnTraceIdentifierAccepted OBJECT-TYPE The actual trace identifier received. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(3). Its value is unspecified if optIfOTSnCurrentStatus has either or both of the losO(5) and los(6) bits set. This object does not apply to reduced-capability systems (i.e., those for which optIfOTMnReduced has the value true(1)) or at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1 has the value 'IrDI'). | 1.3.6.1.2.1.10.133.1.3.1.1.7 | OptIfAcTI | read-only | current |
| optIfOTSnTIMDetMode OBJECT-TYPE Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(3). The default value is off(1). This object does not apply to reduced-capability systems (i.e., those for which optIfOTMnReduced has the value true(1)) or at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1 has the value 'IrDI'). The default value of this object is off(1). | 1.3.6.1.2.1.10.133.1.3.1.1.8 | OptIfTIMDetMode | read-write | current |
| optIfOTSnTIMActEnabled OBJECT-TYPE Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(3). It has no effect when the value of optIfOTSnTIMDetMode is off(1). This object does not apply to reduced-capability systems (i.e., those for which optIfOTMnReduced has the value true(1)) or at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1 has the value 'IrDI'). The default value of this object is false(2). | 1.3.6.1.2.1.10.133.1.3.1.1.9 | TruthValue | read-write | current |
| optIfOTSnCurrentStatus OBJECT-TYPE Indicates the defect condition of the entity, if any. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(3). In reduced-capability systems or at IrDI interfaces the only bit position that may be set is los(6). | 1.3.6.1.2.1.10.133.1.3.1.1.10 | Bits {bdiP(0), bdiO(1), bdi(2), tim(3), losP(4), losO(5), los(6)} | read-only | current |
| optIfOTSnSinkCurrentTable OBJECT-TYPE A table of OTSn sink performance monitoring information for the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.3.2 | not-accessible | current | |
| optIfOTSnSinkCurrentEntry OBJECT-TYPE A conceptual row that contains OTSn sink performance monitoring information of an interface for the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.3.2.1 | not-accessible | current | |
| optIfOTSnSinkCurrentSuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.3.2.1.1 | TruthValue | read-only | current |
| optIfOTSnSinkCurrentInputPower OBJECT-TYPE The optical power monitored at the input. | 1.3.6.1.2.1.10.133.1.3.2.1.2 | Integer32 | read-only | current |
| optIfOTSnSinkCurrentLowInputPower OBJECT-TYPE The lowest optical power monitored at the input during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.3.2.1.3 | Integer32 | read-only | current |
| optIfOTSnSinkCurrentHighInputPower OBJECT-TYPE The highest optical power monitored at the input during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.3.2.1.4 | Integer32 | read-only | current |
| optIfOTSnSinkCurrentLowerInputPowerThreshold OBJECT-TYPE The lower limit threshold on input power. If optIfOTSnSinkCurrentInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.3.2.1.5 | Integer32 | read-write | current |
| optIfOTSnSinkCurrentUpperInputPowerThreshold OBJECT-TYPE The upper limit threshold on input power. If optIfOTSnSinkCurrentInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.3.2.1.6 | Integer32 | read-write | current |
| optIfOTSnSinkCurrentOutputPower OBJECT-TYPE The optical power monitored at the output. | 1.3.6.1.2.1.10.133.1.3.2.1.7 | Integer32 | read-only | current |
| optIfOTSnSinkCurrentLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.3.2.1.8 | Integer32 | read-only | current |
| optIfOTSnSinkCurrentHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.3.2.1.9 | Integer32 | read-only | current |
| optIfOTSnSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE The lower limit threshold on output power. If optIfOTSnSinkCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.3.2.1.10 | Integer32 | read-write | current |
| optIfOTSnSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE The upper limit threshold on output power. If optIfOTSnSinkCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.3.2.1.11 | Integer32 | read-write | current |
| optIfOTSnSinkIntervalTable OBJECT-TYPE A table of historical OTSn sink performance monitoring information. | 1.3.6.1.2.1.10.133.1.3.3 | not-accessible | current | |
| optIfOTSnSinkIntervalEntry OBJECT-TYPE A conceptual row that contains OTSn sink performance monitoring information of an interface during a particular historical interval. | 1.3.6.1.2.1.10.133.1.3.3.1 | not-accessible | current | |
| optIfOTSnSinkIntervalNumber OBJECT-TYPE Uniquely identifies the interval. | 1.3.6.1.2.1.10.133.1.3.3.1.1 | OptIfIntervalNumber | not-accessible | current |
| optIfOTSnSinkIntervalSuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.3.3.1.2 | TruthValue | read-only | current |
| optIfOTSnSinkIntervalLastInputPower OBJECT-TYPE The last optical power monitored at the input during the interval. | 1.3.6.1.2.1.10.133.1.3.3.1.3 | Integer32 | read-only | current |
| optIfOTSnSinkIntervalLowInputPower OBJECT-TYPE The lowest optical power monitored at the input during the interval. | 1.3.6.1.2.1.10.133.1.3.3.1.4 | Integer32 | read-only | current |
| optIfOTSnSinkIntervalHighInputPower OBJECT-TYPE The highest optical power monitored at the input during the interval. | 1.3.6.1.2.1.10.133.1.3.3.1.5 | Integer32 | read-only | current |
| optIfOTSnSinkIntervalLastOutputPower OBJECT-TYPE The last optical power monitored at the output during the interval. | 1.3.6.1.2.1.10.133.1.3.3.1.6 | Integer32 | read-only | current |
| optIfOTSnSinkIntervalLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the interval. | 1.3.6.1.2.1.10.133.1.3.3.1.7 | Integer32 | read-only | current |
| optIfOTSnSinkIntervalHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the interval. | 1.3.6.1.2.1.10.133.1.3.3.1.8 | Integer32 | read-only | current |
| optIfOTSnSinkCurDayTable OBJECT-TYPE A table of OTSn sink performance monitoring information for the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.4 | not-accessible | current | |
| optIfOTSnSinkCurDayEntry OBJECT-TYPE A conceptual row that contains OTSn sink performance monitoring information of an interface for the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.4.1 | not-accessible | current | |
| optIfOTSnSinkCurDaySuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.3.4.1.1 | TruthValue | read-only | current |
| optIfOTSnSinkCurDayLowInputPower OBJECT-TYPE The lowest optical power monitored at the input during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.4.1.2 | Integer32 | read-only | current |
| optIfOTSnSinkCurDayHighInputPower OBJECT-TYPE The highest optical power monitored at the input during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.4.1.3 | Integer32 | read-only | current |
| optIfOTSnSinkCurDayLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.4.1.4 | Integer32 | read-only | current |
| optIfOTSnSinkCurDayHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.4.1.5 | Integer32 | read-only | current |
| optIfOTSnSinkPrevDayTable OBJECT-TYPE A table of OTSn sink performance monitoring information for the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.5 | not-accessible | current | |
| optIfOTSnSinkPrevDayEntry OBJECT-TYPE A conceptual row that contains OTSn sink performance monitoring information of an interface for the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.5.1 | not-accessible | current | |
| optIfOTSnSinkPrevDaySuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.3.5.1.1 | TruthValue | read-only | current |
| optIfOTSnSinkPrevDayLastInputPower OBJECT-TYPE The last optical power monitored at the input during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.5.1.2 | Integer32 | read-only | current |
| optIfOTSnSinkPrevDayLowInputPower OBJECT-TYPE The lowest optical power monitored at the input during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.5.1.3 | Integer32 | read-only | current |
| optIfOTSnSinkPrevDayHighInputPower OBJECT-TYPE The highest optical power monitored at the input during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.5.1.4 | Integer32 | read-only | current |
| optIfOTSnSinkPrevDayLastOutputPower OBJECT-TYPE The last optical power monitored at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.5.1.5 | Integer32 | read-only | current |
| optIfOTSnSinkPrevDayLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.5.1.6 | Integer32 | read-only | current |
| optIfOTSnSinkPrevDayHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.5.1.7 | Integer32 | read-only | current |
| optIfOTSnSrcCurrentTable OBJECT-TYPE A table of OTSn source performance monitoring information for the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.3.6 | not-accessible | current | |
| optIfOTSnSrcCurrentEntry OBJECT-TYPE A conceptual row that contains OTSn source performance monitoring information of an interface for the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.3.6.1 | not-accessible | current | |
| optIfOTSnSrcCurrentSuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.3.6.1.1 | TruthValue | read-only | current |
| optIfOTSnSrcCurrentOutputPower OBJECT-TYPE The optical power monitored at the output. | 1.3.6.1.2.1.10.133.1.3.6.1.2 | Integer32 | read-only | current |
| optIfOTSnSrcCurrentLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.3.6.1.3 | Integer32 | read-only | current |
| optIfOTSnSrcCurrentHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.3.6.1.4 | Integer32 | read-only | current |
| optIfOTSnSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE The lower limit threshold on output power. If optIfOTSnSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.3.6.1.5 | Integer32 | read-write | current |
| optIfOTSnSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE The upper limit threshold on output power. If optIfOTSnSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.3.6.1.6 | Integer32 | read-write | current |
| optIfOTSnSrcCurrentInputPower OBJECT-TYPE The optical power monitored at the input. | 1.3.6.1.2.1.10.133.1.3.6.1.7 | Integer32 | read-only | current |
| optIfOTSnSrcCurrentLowInputPower OBJECT-TYPE The lowest optical power monitored at the input during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.3.6.1.8 | Integer32 | read-only | current |
| optIfOTSnSrcCurrentHighInputPower OBJECT-TYPE The highest optical power monitored at the input during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.3.6.1.9 | Integer32 | read-only | current |
| optIfOTSnSrcCurrentLowerInputPowerThreshold OBJECT-TYPE The lower limit threshold on input power. If optIfOTSnSrcCurrentInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.3.6.1.10 | Integer32 | read-write | current |
| optIfOTSnSrcCurrentUpperInputPowerThreshold OBJECT-TYPE The upper limit threshold on input power. If optIfOTSnSrcCurrentInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.3.6.1.11 | Integer32 | read-write | current |
| optIfOTSnSrcIntervalTable OBJECT-TYPE A table of historical OTSn source performance monitoring information. | 1.3.6.1.2.1.10.133.1.3.7 | not-accessible | current | |
| optIfOTSnSrcIntervalEntry OBJECT-TYPE A conceptual row that contains OTSn source performance monitoring information of an interface during a particular historical interval. | 1.3.6.1.2.1.10.133.1.3.7.1 | not-accessible | current | |
| optIfOTSnSrcIntervalNumber OBJECT-TYPE Uniquely identifies the interval. | 1.3.6.1.2.1.10.133.1.3.7.1.1 | OptIfIntervalNumber | not-accessible | current |
| optIfOTSnSrcIntervalSuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.3.7.1.2 | TruthValue | read-only | current |
| optIfOTSnSrcIntervalLastOutputPower OBJECT-TYPE The last optical power monitored at the output during the interval. | 1.3.6.1.2.1.10.133.1.3.7.1.3 | Integer32 | read-only | current |
| optIfOTSnSrcIntervalLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the interval. | 1.3.6.1.2.1.10.133.1.3.7.1.4 | Integer32 | read-only | current |
| optIfOTSnSrcIntervalHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the interval. | 1.3.6.1.2.1.10.133.1.3.7.1.5 | Integer32 | read-only | current |
| optIfOTSnSrcIntervalLastInputPower OBJECT-TYPE The last optical power monitored at the input during the interval. | 1.3.6.1.2.1.10.133.1.3.7.1.6 | Integer32 | read-only | current |
| optIfOTSnSrcIntervalLowInputPower OBJECT-TYPE The lowest optical power monitored at the input during the interval. | 1.3.6.1.2.1.10.133.1.3.7.1.7 | Integer32 | read-only | current |
| optIfOTSnSrcIntervalHighInputPower OBJECT-TYPE The highest optical power monitored at the input during the interval. | 1.3.6.1.2.1.10.133.1.3.7.1.8 | Integer32 | read-only | current |
| optIfOTSnSrcCurDayTable OBJECT-TYPE A table of OTSn source performance monitoring information for the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.8 | not-accessible | current | |
| optIfOTSnSrcCurDayEntry OBJECT-TYPE A conceptual row that contains OTSn source performance monitoring information of an interface for the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.8.1 | not-accessible | current | |
| optIfOTSnSrcCurDaySuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.3.8.1.1 | TruthValue | read-only | current |
| optIfOTSnSrcCurDayLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.8.1.2 | Integer32 | read-only | current |
| optIfOTSnSrcCurDayHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.8.1.3 | Integer32 | read-only | current |
| optIfOTSnSrcCurDayLowInputPower OBJECT-TYPE The lowest optical power monitored at the input during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.8.1.4 | Integer32 | read-only | current |
| optIfOTSnSrcCurDayHighInputPower OBJECT-TYPE The highest optical power monitored at the input during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.8.1.5 | Integer32 | read-only | current |
| optIfOTSnSrcPrevDayTable OBJECT-TYPE A table of OTSn source performance monitoring information for the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.9 | not-accessible | current | |
| optIfOTSnSrcPrevDayEntry OBJECT-TYPE A conceptual row that contains OTSn source performance monitoring information of an interface for the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.9.1 | not-accessible | current | |
| optIfOTSnSrcPrevDaySuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.3.9.1.1 | TruthValue | read-only | current |
| optIfOTSnSrcPrevDayLastOutputPower OBJECT-TYPE The last optical power monitored at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.9.1.2 | Integer32 | read-only | current |
| optIfOTSnSrcPrevDayLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.9.1.3 | Integer32 | read-only | current |
| optIfOTSnSrcPrevDayHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.9.1.4 | Integer32 | read-only | current |
| optIfOTSnSrcPrevDayLastInputPower OBJECT-TYPE The last optical power monitored at the input during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.9.1.5 | Integer32 | read-only | current |
| optIfOTSnSrcPrevDayLowInputPower OBJECT-TYPE The lowest optical power monitored at the input during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.9.1.6 | Integer32 | read-only | current |
| optIfOTSnSrcPrevDayHighInputPower OBJECT-TYPE The highest optical power monitored at the input during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.3.9.1.7 | Integer32 | read-only | current |
| optIfOMSn OBJECT-IDENTITY | 1.3.6.1.2.1.10.133.1.4 | |||
| optIfOMSnConfigTable OBJECT-TYPE A table of OMSn configuration information. | 1.3.6.1.2.1.10.133.1.4.1 | not-accessible | current | |
| optIfOMSnConfigEntry OBJECT-TYPE A conceptual row that contains OMSn configuration information of an interface. | 1.3.6.1.2.1.10.133.1.4.1.1 | not-accessible | current | |
| optIfOMSnDirectionality OBJECT-TYPE Indicates the directionality of the entity. | 1.3.6.1.2.1.10.133.1.4.1.1.1 | OptIfDirectionality | read-only | current |
| optIfOMSnCurrentStatus OBJECT-TYPE Indicates the defect condition of the entity, if any. This object is applicable only to full capability systems whose interface type is IaDI and for which optIfOMSnDirectionality has the value sink(1) or bidirectional(3). | 1.3.6.1.2.1.10.133.1.4.1.1.2 | Bits {ssfP(0), ssfO(1), ssf(2), bdiP(3), bdiO(4), bdi(5), losP(6)} | read-only | current |
| optIfOMSnSinkCurrentTable OBJECT-TYPE A table of OMSn sink performance monitoring information for the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.4.2 | not-accessible | current | |
| optIfOMSnSinkCurrentEntry OBJECT-TYPE A conceptual row that contains OMSn sink performance monitoring information of an interface for the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.4.2.1 | not-accessible | current | |
| optIfOMSnSinkCurrentSuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.4.2.1.1 | TruthValue | read-only | current |
| optIfOMSnSinkCurrentAggregatedInputPower OBJECT-TYPE The aggregated optical power of all the DWDM input channels. | 1.3.6.1.2.1.10.133.1.4.2.1.2 | Integer32 | read-only | current |
| optIfOMSnSinkCurrentLowAggregatedInputPower OBJECT-TYPE The lowest aggregated optical power of all the DWDM input channels during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.4.2.1.3 | Integer32 | read-only | current |
| optIfOMSnSinkCurrentHighAggregatedInputPower OBJECT-TYPE The highest aggregated optical power of all the DWDM input channels during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.4.2.1.4 | Integer32 | read-only | current |
| optIfOMSnSinkCurrentLowerInputPowerThreshold OBJECT-TYPE The lower limit threshold on aggregated input power. If optIfOMSnSinkCurrentAggregatedInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.4.2.1.5 | Integer32 | read-write | current |
| optIfOMSnSinkCurrentUpperInputPowerThreshold OBJECT-TYPE The upper limit threshold on aggregated input power. If optIfOMSnSinkCurrentAggregatedInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.4.2.1.6 | Integer32 | read-write | current |
| optIfOMSnSinkCurrentOutputPower OBJECT-TYPE The optical power monitored at the output. | 1.3.6.1.2.1.10.133.1.4.2.1.7 | Integer32 | read-only | current |
| optIfOMSnSinkCurrentLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.4.2.1.8 | Integer32 | read-only | current |
| optIfOMSnSinkCurrentHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.4.2.1.9 | Integer32 | read-only | current |
| optIfOMSnSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE The lower limit threshold on output power. If optIfOMSnSinkCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.4.2.1.10 | Integer32 | read-write | current |
| optIfOMSnSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE The upper limit threshold on output power. If optIfOMSnSinkCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.4.2.1.11 | Integer32 | read-write | current |
| optIfOMSnSinkIntervalTable OBJECT-TYPE A table of historical OMSn sink performance monitoring information. | 1.3.6.1.2.1.10.133.1.4.3 | not-accessible | current | |
| optIfOMSnSinkIntervalEntry OBJECT-TYPE A conceptual row that contains OMSn sink performance monitoring information of an interface during a particular historical interval. | 1.3.6.1.2.1.10.133.1.4.3.1 | not-accessible | current | |
| optIfOMSnSinkIntervalNumber OBJECT-TYPE Uniquely identifies the interval. | 1.3.6.1.2.1.10.133.1.4.3.1.1 | OptIfIntervalNumber | not-accessible | current |
| optIfOMSnSinkIntervalSuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.4.3.1.2 | TruthValue | read-only | current |
| optIfOMSnSinkIntervalLastAggregatedInputPower OBJECT-TYPE The last aggregated optical power of all the DWDM input channels during the interval. | 1.3.6.1.2.1.10.133.1.4.3.1.3 | Integer32 | read-only | current |
| optIfOMSnSinkIntervalLowAggregatedInputPower OBJECT-TYPE The lowest aggregated optical power of all the DWDM input channels during the interval. | 1.3.6.1.2.1.10.133.1.4.3.1.4 | Integer32 | read-only | current |
| optIfOMSnSinkIntervalHighAggregatedInputPower OBJECT-TYPE The highest aggregated optical power of all the DWDM input channels during the interval. | 1.3.6.1.2.1.10.133.1.4.3.1.5 | Integer32 | read-only | current |
| optIfOMSnSinkIntervalLastOutputPower OBJECT-TYPE The last optical power at the output during the interval. | 1.3.6.1.2.1.10.133.1.4.3.1.6 | Integer32 | read-only | current |
| optIfOMSnSinkIntervalLowOutputPower OBJECT-TYPE The lowest optical power at the output during the interval. | 1.3.6.1.2.1.10.133.1.4.3.1.7 | Integer32 | read-only | current |
| optIfOMSnSinkIntervalHighOutputPower OBJECT-TYPE The highest optical power at the output during the interval. | 1.3.6.1.2.1.10.133.1.4.3.1.8 | Integer32 | read-only | current |
| optIfOMSnSinkCurDayTable OBJECT-TYPE A table of OMSn sink performance monitoring information for the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.4 | not-accessible | current | |
| optIfOMSnSinkCurDayEntry OBJECT-TYPE A conceptual row that contains OMSn sink performance monitoring information of an interface for the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.4.1 | not-accessible | current | |
| optIfOMSnSinkCurDaySuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.4.4.1.1 | TruthValue | read-only | current |
| optIfOMSnSinkCurDayLowAggregatedInputPower OBJECT-TYPE The lowest aggregated optical power of all the DWDM input channels during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.4.1.2 | Integer32 | read-only | current |
| optIfOMSnSinkCurDayHighAggregatedInputPower OBJECT-TYPE The highest aggregated optical power of all the DWDM input channels during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.4.1.3 | Integer32 | read-only | current |
| optIfOMSnSinkCurDayLowOutputPower OBJECT-TYPE The lowest optical power at the output during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.4.1.4 | Integer32 | read-only | current |
| optIfOMSnSinkCurDayHighOutputPower OBJECT-TYPE The highest optical power at the output during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.4.1.5 | Integer32 | read-only | current |
| optIfOMSnSinkPrevDayTable OBJECT-TYPE A table of OMSn sink performance monitoring information for the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.5 | not-accessible | current | |
| optIfOMSnSinkPrevDayEntry OBJECT-TYPE A conceptual row that contains OMSn sink performance monitoring information of an interface for the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.5.1 | not-accessible | current | |
| optIfOMSnSinkPrevDaySuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.4.5.1.1 | TruthValue | read-only | current |
| optIfOMSnSinkPrevDayLastAggregatedInputPower OBJECT-TYPE The last aggregated optical power of all the DWDM input channels during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.5.1.2 | Integer32 | read-only | current |
| optIfOMSnSinkPrevDayLowAggregatedInputPower OBJECT-TYPE The lowest aggregated optical power of all the DWDM input channels during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.5.1.3 | Integer32 | read-only | current |
| optIfOMSnSinkPrevDayHighAggregatedInputPower OBJECT-TYPE The highest aggregated optical power of all the DWDM input channels during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.5.1.4 | Integer32 | read-only | current |
| optIfOMSnSinkPrevDayLastOutputPower OBJECT-TYPE The last optical power at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.5.1.5 | Integer32 | read-only | current |
| optIfOMSnSinkPrevDayLowOutputPower OBJECT-TYPE The lowest optical power at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.5.1.6 | Integer32 | read-only | current |
| optIfOMSnSinkPrevDayHighOutputPower OBJECT-TYPE The highest optical power at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.5.1.7 | Integer32 | read-only | current |
| optIfOMSnSrcCurrentTable OBJECT-TYPE A table of OMSn source performance monitoring information for the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.4.6 | not-accessible | current | |
| optIfOMSnSrcCurrentEntry OBJECT-TYPE A conceptual row that contains OMSn source performance monitoring information of an interface for the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.4.6.1 | not-accessible | current | |
| optIfOMSnSrcCurrentSuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.4.6.1.1 | TruthValue | read-only | current |
| optIfOMSnSrcCurrentOutputPower OBJECT-TYPE The optical power monitored at the output. | 1.3.6.1.2.1.10.133.1.4.6.1.2 | Integer32 | read-only | current |
| optIfOMSnSrcCurrentLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.4.6.1.3 | Integer32 | read-only | current |
| optIfOMSnSrcCurrentHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.4.6.1.4 | Integer32 | read-only | current |
| optIfOMSnSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE The lower limit threshold on output power. If optIfOMSnSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.4.6.1.5 | Integer32 | read-write | current |
| optIfOMSnSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE The upper limit threshold on output power. If optIfOMSnSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.4.6.1.6 | Integer32 | read-write | current |
| optIfOMSnSrcCurrentAggregatedInputPower OBJECT-TYPE The aggregated optical power at the input. | 1.3.6.1.2.1.10.133.1.4.6.1.7 | Integer32 | read-only | current |
| optIfOMSnSrcCurrentLowAggregatedInputPower OBJECT-TYPE The lowest aggregated optical power at the input during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.4.6.1.8 | Integer32 | read-only | current |
| optIfOMSnSrcCurrentHighAggregatedInputPower OBJECT-TYPE The highest aggregated optical power at the input during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.4.6.1.9 | Integer32 | read-only | current |
| optIfOMSnSrcCurrentLowerInputPowerThreshold OBJECT-TYPE The lower limit threshold on aggregated input power. If optIfOMSnSrcCurrentAggregatedInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.4.6.1.10 | Integer32 | read-write | current |
| optIfOMSnSrcCurrentUpperInputPowerThreshold OBJECT-TYPE The upper limit threshold on aggregated input power. If optIfOMSnSrcCurrentAggregatedInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.4.6.1.11 | Integer32 | read-write | current |
| optIfOMSnSrcIntervalTable OBJECT-TYPE A table of historical OMSn source performance monitoring information. | 1.3.6.1.2.1.10.133.1.4.7 | not-accessible | current | |
| optIfOMSnSrcIntervalEntry OBJECT-TYPE A conceptual row that contains OMSn source performance monitoring information of an interface during a particular historical interval. | 1.3.6.1.2.1.10.133.1.4.7.1 | not-accessible | current | |
| optIfOMSnSrcIntervalNumber OBJECT-TYPE Uniquely identifies the interval. | 1.3.6.1.2.1.10.133.1.4.7.1.1 | OptIfIntervalNumber | not-accessible | current |
| optIfOMSnSrcIntervalSuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.4.7.1.2 | TruthValue | read-only | current |
| optIfOMSnSrcIntervalLastOutputPower OBJECT-TYPE The last optical power monitored at the output during the interval. | 1.3.6.1.2.1.10.133.1.4.7.1.3 | Integer32 | read-only | current |
| optIfOMSnSrcIntervalLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the interval. | 1.3.6.1.2.1.10.133.1.4.7.1.4 | Integer32 | read-only | current |
| optIfOMSnSrcIntervalHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the interval. | 1.3.6.1.2.1.10.133.1.4.7.1.5 | Integer32 | read-only | current |
| optIfOMSnSrcIntervalLastAggregatedInputPower OBJECT-TYPE The last aggregated optical power at the input during the interval. | 1.3.6.1.2.1.10.133.1.4.7.1.6 | Integer32 | read-only | current |
| optIfOMSnSrcIntervalLowAggregatedInputPower OBJECT-TYPE The lowest aggregated optical power at the input during the interval. | 1.3.6.1.2.1.10.133.1.4.7.1.7 | Integer32 | read-only | current |
| optIfOMSnSrcIntervalHighAggregatedInputPower OBJECT-TYPE The highest aggregated optical power at the input during the interval. | 1.3.6.1.2.1.10.133.1.4.7.1.8 | Integer32 | read-only | current |
| optIfOMSnSrcCurDayTable OBJECT-TYPE A table of OMSn source performance monitoring information for the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.8 | not-accessible | current | |
| optIfOMSnSrcCurDayEntry OBJECT-TYPE A conceptual row that contains OMSn source performance monitoring information of an interface for the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.8.1 | not-accessible | current | |
| optIfOMSnSrcCurDaySuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.4.8.1.1 | TruthValue | read-only | current |
| optIfOMSnSrcCurDayLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.8.1.2 | Integer32 | read-only | current |
| optIfOMSnSrcCurDayHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.8.1.3 | Integer32 | read-only | current |
| optIfOMSnSrcCurDayLowAggregatedInputPower OBJECT-TYPE The lowest aggregated optical power at the input during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.8.1.4 | Integer32 | read-only | current |
| optIfOMSnSrcCurDayHighAggregatedInputPower OBJECT-TYPE The highest aggregated optical power at the input during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.8.1.5 | Integer32 | read-only | current |
| optIfOMSnSrcPrevDayTable OBJECT-TYPE A table of OMSn source performance monitoring information for the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.9 | not-accessible | current | |
| optIfOMSnSrcPrevDayEntry OBJECT-TYPE A conceptual row that contains OMSn source performance monitoring information of an interface for the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.9.1 | not-accessible | current | |
| optIfOMSnSrcPrevDaySuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.4.9.1.1 | TruthValue | read-only | current |
| optIfOMSnSrcPrevDayLastOutputPower OBJECT-TYPE The last optical power monitored at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.9.1.2 | Integer32 | read-only | current |
| optIfOMSnSrcPrevDayLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.9.1.3 | Integer32 | read-only | current |
| optIfOMSnSrcPrevDayHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.9.1.4 | Integer32 | read-only | current |
| optIfOMSnSrcPrevDayLastAggregatedInputPower OBJECT-TYPE The last aggregated optical power at the input during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.9.1.5 | Integer32 | read-only | current |
| optIfOMSnSrcPrevDayLowAggregatedInputPower OBJECT-TYPE The lowest aggregated optical power at the input during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.9.1.6 | Integer32 | read-only | current |
| optIfOMSnSrcPrevDayHighAggregatedInputPower OBJECT-TYPE The highest aggregated optical power at the input during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.4.9.1.7 | Integer32 | read-only | current |
| optIfOChGroup OBJECT-IDENTITY | 1.3.6.1.2.1.10.133.1.5 | |||
| optIfOChGroupConfigTable OBJECT-TYPE A table of OChGroup configuration information. | 1.3.6.1.2.1.10.133.1.5.1 | not-accessible | current | |
| optIfOChGroupConfigEntry OBJECT-TYPE A conceptual row that contains OChGroup configuration information of an interface. | 1.3.6.1.2.1.10.133.1.5.1.1 | not-accessible | current | |
| optIfOChGroupDirectionality OBJECT-TYPE Indicates the directionality of the entity. | 1.3.6.1.2.1.10.133.1.5.1.1.1 | OptIfDirectionality | read-only | current |
| optIfOChGroupSinkCurrentTable OBJECT-TYPE A table of OChGroup sink performance monitoring information for the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.5.2 | not-accessible | current | |
| optIfOChGroupSinkCurrentEntry OBJECT-TYPE A conceptual row that contains OChGroup sink performance monitoring information of an interface for the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.5.2.1 | not-accessible | current | |
| optIfOChGroupSinkCurrentSuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.5.2.1.1 | TruthValue | read-only | current |
| optIfOChGroupSinkCurrentAggregatedInputPower OBJECT-TYPE The aggregated optical power of all the DWDM input channels in the OChGroup. | 1.3.6.1.2.1.10.133.1.5.2.1.2 | Integer32 | read-only | current |
| optIfOChGroupSinkCurrentLowAggregatedInputPower OBJECT-TYPE The lowest aggregated optical power of all the DWDM input channels in the OChGroup during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.5.2.1.3 | Integer32 | read-only | current |
| optIfOChGroupSinkCurrentHighAggregatedInputPower OBJECT-TYPE The highest aggregated optical power of all the DWDM input channels in the OChGroup during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.5.2.1.4 | Integer32 | read-only | current |
| optIfOChGroupSinkCurrentLowerInputPowerThreshold OBJECT-TYPE The lower limit threshold on aggregated input power. If optIfOChGroupSinkCurrentAggregatedInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.5.2.1.5 | Integer32 | read-write | current |
| optIfOChGroupSinkCurrentUpperInputPowerThreshold OBJECT-TYPE The upper limit threshold on aggregated input power. If optIfOChGroupSinkCurrentAggregatedInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.5.2.1.6 | Integer32 | read-write | current |
| optIfOChGroupSinkCurrentOutputPower OBJECT-TYPE The optical power monitored at the output in the OChGroup. | 1.3.6.1.2.1.10.133.1.5.2.1.7 | Integer32 | read-only | current |
| optIfOChGroupSinkCurrentLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output in the OChGroup during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.5.2.1.8 | Integer32 | read-only | current |
| optIfOChGroupSinkCurrentHighOutputPower OBJECT-TYPE The highest optical power monitored at the output in the OChGroup during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.5.2.1.9 | Integer32 | read-only | current |
| optIfOChGroupSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE The lower limit threshold on the output power. If optIfOChGroupSinkCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.5.2.1.10 | Integer32 | read-write | current |
| optIfOChGroupSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE The upper limit threshold on the output power. If optIfOChGroupSinkCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.5.2.1.11 | Integer32 | read-write | current |
| optIfOChGroupSinkIntervalTable OBJECT-TYPE A table of historical OChGroup sink performance monitoring information. | 1.3.6.1.2.1.10.133.1.5.3 | not-accessible | current | |
| optIfOChGroupSinkIntervalEntry OBJECT-TYPE A conceptual row that contains OChGroup sink performance monitoring information of an interface during a particular historical interval. | 1.3.6.1.2.1.10.133.1.5.3.1 | not-accessible | current | |
| optIfOChGroupSinkIntervalNumber OBJECT-TYPE Uniquely identifies the interval. | 1.3.6.1.2.1.10.133.1.5.3.1.1 | OptIfIntervalNumber | not-accessible | current |
| optIfOChGroupSinkIntervalSuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.5.3.1.2 | TruthValue | read-only | current |
| optIfOChGroupSinkIntervalLastAggregatedInputPower OBJECT-TYPE The last aggregated optical power of all the DWDM input channels in the OChGroup during the interval. | 1.3.6.1.2.1.10.133.1.5.3.1.3 | Integer32 | read-only | current |
| optIfOChGroupSinkIntervalLowAggregatedInputPower OBJECT-TYPE The lowest aggregated optical power of all the DWDM input channels in the OChGroup during the interval. | 1.3.6.1.2.1.10.133.1.5.3.1.4 | Integer32 | read-only | current |
| optIfOChGroupSinkIntervalHighAggregatedInputPower OBJECT-TYPE The highest aggregated optical power of all the DWDM input channels in the OChGroup during the interval. | 1.3.6.1.2.1.10.133.1.5.3.1.5 | Integer32 | read-only | current |
| optIfOChGroupSinkIntervalLastOutputPower OBJECT-TYPE The last optical power monitored at the output in the OChGroup during the interval. | 1.3.6.1.2.1.10.133.1.5.3.1.6 | Integer32 | read-only | current |
| optIfOChGroupSinkIntervalLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output in the OChGroup during the interval. | 1.3.6.1.2.1.10.133.1.5.3.1.7 | Integer32 | read-only | current |
| optIfOChGroupSinkIntervalHighOutputPower OBJECT-TYPE The highest optical power monitored at the output in the OChGroup during the interval. | 1.3.6.1.2.1.10.133.1.5.3.1.8 | Integer32 | read-only | current |
| optIfOChGroupSinkCurDayTable OBJECT-TYPE A table of OChGroup sink performance monitoring information for the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.4 | not-accessible | current | |
| optIfOChGroupSinkCurDayEntry OBJECT-TYPE A conceptual row that contains OChGroup sink performance monitoring information of an interface for the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.4.1 | not-accessible | current | |
| optIfOChGroupSinkCurDaySuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.5.4.1.1 | TruthValue | read-only | current |
| optIfOChGroupSinkCurDayLowAggregatedInputPower OBJECT-TYPE The lowest aggregated optical power of all the DWDM input channels in the OChGroup during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.4.1.2 | Integer32 | read-only | current |
| optIfOChGroupSinkCurDayHighAggregatedInputPower OBJECT-TYPE The highest aggregated optical power of all the DWDM input channels in the OChGroup during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.4.1.3 | Integer32 | read-only | current |
| optIfOChGroupSinkCurDayLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output in the OChGroup during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.4.1.4 | Integer32 | read-only | current |
| optIfOChGroupSinkCurDayHighOutputPower OBJECT-TYPE The highest optical power monitored at the output in the OChGroup during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.4.1.5 | Integer32 | read-only | current |
| optIfOChGroupSinkPrevDayTable OBJECT-TYPE A table of OChGroup sink performance monitoring information for the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.5 | not-accessible | current | |
| optIfOChGroupSinkPrevDayEntry OBJECT-TYPE A conceptual row that contains OChGroup sink performance monitoring information of an interface for the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.5.1 | not-accessible | current | |
| optIfOChGroupSinkPrevDaySuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.5.5.1.1 | TruthValue | read-only | current |
| optIfOChGroupSinkPrevDayLastAggregatedInputPower OBJECT-TYPE The last aggregated optical power of all the DWDM input channels in the OChGroup during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.5.1.2 | Integer32 | read-only | current |
| optIfOChGroupSinkPrevDayLowAggregatedInputPower OBJECT-TYPE The lowest aggregated optical power of all the DWDM input channels in the OChGroup during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.5.1.3 | Integer32 | read-only | current |
| optIfOChGroupSinkPrevDayHighAggregatedInputPower OBJECT-TYPE The highest aggregated optical power of all the DWDM input channels in the OChGroup during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.5.1.4 | Integer32 | read-only | current |
| optIfOChGroupSinkPrevDayLastOutputPower OBJECT-TYPE The last optical power monitored at the output in the OChGroup during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.5.1.5 | Integer32 | read-only | current |
| optIfOChGroupSinkPrevDayLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output in the OChGroup during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.5.1.6 | Integer32 | read-only | current |
| optIfOChGroupSinkPrevDayHighOutputPower OBJECT-TYPE The highest optical power monitored at the output in the OChGroup during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.5.1.7 | Integer32 | read-only | current |
| optIfOChGroupSrcCurrentTable OBJECT-TYPE A table of OChGroup source performance monitoring information for the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.5.6 | not-accessible | current | |
| optIfOChGroupSrcCurrentEntry OBJECT-TYPE A conceptual row that contains OChGroup source performance monitoring information of an interface for the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.5.6.1 | not-accessible | current | |
| optIfOChGroupSrcCurrentSuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.5.6.1.1 | TruthValue | read-only | current |
| optIfOChGroupSrcCurrentOutputPower OBJECT-TYPE The optical power monitored at the output. | 1.3.6.1.2.1.10.133.1.5.6.1.2 | Integer32 | read-only | current |
| optIfOChGroupSrcCurrentLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.5.6.1.3 | Integer32 | read-only | current |
| optIfOChGroupSrcCurrentHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.5.6.1.4 | Integer32 | read-only | current |
| optIfOChGroupSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE The lower limit threshold on output power. If optIfOChGroupSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.5.6.1.5 | Integer32 | read-write | current |
| optIfOChGroupSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE The upper limit threshold on output power. If optIfOChGroupSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.5.6.1.6 | Integer32 | read-write | current |
| optIfOChGroupSrcCurrentAggregatedInputPower OBJECT-TYPE The aggregated optical power monitored at the input. | 1.3.6.1.2.1.10.133.1.5.6.1.7 | Integer32 | read-only | current |
| optIfOChGroupSrcCurrentLowAggregatedInputPower OBJECT-TYPE The lowest aggregated optical power monitored at the input during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.5.6.1.8 | Integer32 | read-only | current |
| optIfOChGroupSrcCurrentHighAggregatedInputPower OBJECT-TYPE The highest aggregated optical power monitored at the input during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.5.6.1.9 | Integer32 | read-only | current |
| optIfOChGroupSrcCurrentLowerInputPowerThreshold OBJECT-TYPE The lower limit threshold on input power. If optIfOChGroupSrcCurrentAggregatedInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.5.6.1.10 | Integer32 | read-write | current |
| optIfOChGroupSrcCurrentUpperInputPowerThreshold OBJECT-TYPE The upper limit threshold on input power. If optIfOChGroupSrcCurrentAggregatedInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.5.6.1.11 | Integer32 | read-write | current |
| optIfOChGroupSrcIntervalTable OBJECT-TYPE A table of historical OChGroup source performance monitoring information. | 1.3.6.1.2.1.10.133.1.5.7 | not-accessible | current | |
| optIfOChGroupSrcIntervalEntry OBJECT-TYPE A conceptual row that contains OChGroup source performance monitoring information of an interface during a particular historical interval. | 1.3.6.1.2.1.10.133.1.5.7.1 | not-accessible | current | |
| optIfOChGroupSrcIntervalNumber OBJECT-TYPE Uniquely identifies the interval. | 1.3.6.1.2.1.10.133.1.5.7.1.1 | OptIfIntervalNumber | not-accessible | current |
| optIfOChGroupSrcIntervalSuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.5.7.1.2 | TruthValue | read-only | current |
| optIfOChGroupSrcIntervalLastOutputPower OBJECT-TYPE The last optical power monitored at the output during the interval. | 1.3.6.1.2.1.10.133.1.5.7.1.3 | Integer32 | read-only | current |
| optIfOChGroupSrcIntervalLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the interval. | 1.3.6.1.2.1.10.133.1.5.7.1.4 | Integer32 | read-only | current |
| optIfOChGroupSrcIntervalHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the interval. | 1.3.6.1.2.1.10.133.1.5.7.1.5 | Integer32 | read-only | current |
| optIfOChGroupSrcIntervalLastAggregatedInputPower OBJECT-TYPE The last aggregated optical power monitored at the input during the interval. | 1.3.6.1.2.1.10.133.1.5.7.1.6 | Integer32 | read-only | current |
| optIfOChGroupSrcIntervalLowAggregatedInputPower OBJECT-TYPE The lowest aggregated optical power monitored at the input during the interval. | 1.3.6.1.2.1.10.133.1.5.7.1.7 | Integer32 | read-only | current |
| optIfOChGroupSrcIntervalHighAggregatedInputPower OBJECT-TYPE The highest aggregated optical power monitored at the input during the interval. | 1.3.6.1.2.1.10.133.1.5.7.1.8 | Integer32 | read-only | current |
| optIfOChGroupSrcCurDayTable OBJECT-TYPE A table of OChGroup source performance monitoring information for the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.8 | not-accessible | current | |
| optIfOChGroupSrcCurDayEntry OBJECT-TYPE A conceptual row that contains OChGroup source performance monitoring information of an interface for the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.8.1 | not-accessible | current | |
| optIfOChGroupSrcCurDaySuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.5.8.1.1 | TruthValue | read-only | current |
| optIfOChGroupSrcCurDayLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.8.1.2 | Integer32 | read-only | current |
| optIfOChGroupSrcCurDayHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.8.1.3 | Integer32 | read-only | current |
| optIfOChGroupSrcCurDayLowAggregatedInputPower OBJECT-TYPE The lowest aggregated optical power monitored at the input during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.8.1.4 | Integer32 | read-only | current |
| optIfOChGroupSrcCurDayHighAggregatedInputPower OBJECT-TYPE The highest aggregated optical power monitored at the input during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.8.1.5 | Integer32 | read-only | current |
| optIfOChGroupSrcPrevDayTable OBJECT-TYPE A table of OChGroup source performance monitoring information for the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.9 | not-accessible | current | |
| optIfOChGroupSrcPrevDayEntry OBJECT-TYPE A conceptual row that contains OChGroup source performance monitoring information of an interface for the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.9.1 | not-accessible | current | |
| optIfOChGroupSrcPrevDaySuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.5.9.1.1 | TruthValue | read-only | current |
| optIfOChGroupSrcPrevDayLastOutputPower OBJECT-TYPE The last optical power monitored at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.9.1.2 | Integer32 | read-only | current |
| optIfOChGroupSrcPrevDayLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.9.1.3 | Integer32 | read-only | current |
| optIfOChGroupSrcPrevDayHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.9.1.4 | Integer32 | read-only | current |
| optIfOChGroupSrcPrevDayLastAggregatedInputPower OBJECT-TYPE The last aggregated optical power monitored at the input during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.9.1.5 | Integer32 | read-only | current |
| optIfOChGroupSrcPrevDayLowAggregatedInputPower OBJECT-TYPE The lowest aggregated optical power monitored at the input during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.9.1.6 | Integer32 | read-only | current |
| optIfOChGroupSrcPrevDayHighAggregatedInputPower OBJECT-TYPE The highest aggregated optical power monitored at the input during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.5.9.1.7 | Integer32 | read-only | current |
| optIfOCh OBJECT-IDENTITY | 1.3.6.1.2.1.10.133.1.6 | |||
| optIfOChConfigTable OBJECT-TYPE A table of OCh configuration information. | 1.3.6.1.2.1.10.133.1.6.1 | not-accessible | current | |
| optIfOChConfigEntry OBJECT-TYPE A conceptual row that contains OCh configuration information of an interface. | 1.3.6.1.2.1.10.133.1.6.1.1 | not-accessible | current | |
| optIfOChDirectionality OBJECT-TYPE Indicates the directionality of the entity. | 1.3.6.1.2.1.10.133.1.6.1.1.1 | OptIfDirectionality | read-only | current |
| optIfOChCurrentStatus OBJECT-TYPE Indicates the defect condition of the entity, if any. This object is applicable when optIfOChDirectionality has the value sink(1) or bidirectional(3). In full-capability systems the bit position los(1) is not used. In reduced-capability systems or at IrDI interfaces only the bit positions los(1) and ssfP(3) are used. | 1.3.6.1.2.1.10.133.1.6.1.1.2 | Bits {losP(0), los(1), oci(2), ssfP(3), ssfO(4), ssf(5)} | read-only | current |
| optIfOChSinkCurrentTable OBJECT-TYPE A table of OCh sink performance monitoring information for the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.6.2 | not-accessible | current | |
| optIfOChSinkCurrentEntry OBJECT-TYPE A conceptual row that contains OCh sink performance monitoring information for an interface for the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.6.2.1 | not-accessible | current | |
| optIfOChSinkCurrentSuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.6.2.1.1 | TruthValue | read-only | current |
| optIfOChSinkCurrentInputPower OBJECT-TYPE The optical power monitored at the input. | 1.3.6.1.2.1.10.133.1.6.2.1.2 | Integer32 | read-only | current |
| optIfOChSinkCurrentLowInputPower OBJECT-TYPE The lowest optical power monitored at the input during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.6.2.1.3 | Integer32 | read-only | current |
| optIfOChSinkCurrentHighInputPower OBJECT-TYPE The highest optical power monitored at the input during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.6.2.1.4 | Integer32 | read-only | current |
| optIfOChSinkCurrentLowerInputPowerThreshold OBJECT-TYPE The lower limit threshold on input power. If optIfOChSinkCurrentInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.6.2.1.5 | Integer32 | read-write | current |
| optIfOChSinkCurrentUpperInputPowerThreshold OBJECT-TYPE The upper limit threshold on input power. If optIfOChSinkCurrentInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.6.2.1.6 | Integer32 | read-write | current |
| optIfOChSinkIntervalTable OBJECT-TYPE A table of historical OCh sink performance monitoring information. | 1.3.6.1.2.1.10.133.1.6.3 | not-accessible | current | |
| optIfOChSinkIntervalEntry OBJECT-TYPE A conceptual row that contains OCh sink performance monitoring information of an interface during a particular historical interval. | 1.3.6.1.2.1.10.133.1.6.3.1 | not-accessible | current | |
| optIfOChSinkIntervalNumber OBJECT-TYPE Uniquely identifies the interval. | 1.3.6.1.2.1.10.133.1.6.3.1.1 | OptIfIntervalNumber | not-accessible | current |
| optIfOChSinkIntervalSuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.6.3.1.2 | TruthValue | read-only | current |
| optIfOChSinkIntervalLastInputPower OBJECT-TYPE The last optical power monitored at the input during the interval. | 1.3.6.1.2.1.10.133.1.6.3.1.3 | Integer32 | read-only | current |
| optIfOChSinkIntervalLowInputPower OBJECT-TYPE The lowest optical power monitored at the input during the interval. | 1.3.6.1.2.1.10.133.1.6.3.1.4 | Integer32 | read-only | current |
| optIfOChSinkIntervalHighInputPower OBJECT-TYPE The highest optical power monitored at the input during the interval. | 1.3.6.1.2.1.10.133.1.6.3.1.5 | Integer32 | read-only | current |
| optIfOChSinkCurDayTable OBJECT-TYPE A table of OCh sink performance monitoring information for the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.4 | not-accessible | current | |
| optIfOChSinkCurDayEntry OBJECT-TYPE A conceptual row that contains OCh sink performance monitoring information of an interface for the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.4.1 | not-accessible | current | |
| optIfOChSinkCurDaySuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.6.4.1.1 | TruthValue | read-only | current |
| optIfOChSinkCurDayLowInputPower OBJECT-TYPE The lowest optical power monitored at the input during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.4.1.2 | Integer32 | read-only | current |
| optIfOChSinkCurDayHighInputPower OBJECT-TYPE The highest optical power monitored at the input during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.4.1.3 | Integer32 | read-only | current |
| optIfOChSinkPrevDayTable OBJECT-TYPE A table of OCh sink performance monitoring information for the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.5 | not-accessible | current | |
| optIfOChSinkPrevDayEntry OBJECT-TYPE A conceptual row that contains OCh sink performance monitoring information of an interface for the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.5.1 | not-accessible | current | |
| optIfOChSinkPrevDaySuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.6.5.1.1 | TruthValue | read-only | current |
| optIfOChSinkPrevDayLastInputPower OBJECT-TYPE The last optical power monitored at the input during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.5.1.2 | Integer32 | read-only | current |
| optIfOChSinkPrevDayLowInputPower OBJECT-TYPE The lowest optical power monitored at the input during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.5.1.3 | Integer32 | read-only | current |
| optIfOChSinkPrevDayHighInputPower OBJECT-TYPE The highest optical power monitored at the input during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.5.1.4 | Integer32 | read-only | current |
| optIfOChSrcCurrentTable OBJECT-TYPE A table of OCh source performance monitoring information for the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.6.6 | not-accessible | current | |
| optIfOChSrcCurrentEntry OBJECT-TYPE A conceptual row that contains OCh source performance monitoring information of an interface for the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.6.6.1 | not-accessible | current | |
| optIfOChSrcCurrentSuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.6.6.1.1 | TruthValue | read-only | current |
| optIfOChSrcCurrentOutputPower OBJECT-TYPE The optical power monitored at the output. | 1.3.6.1.2.1.10.133.1.6.6.1.2 | Integer32 | read-only | current |
| optIfOChSrcCurrentLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.6.6.1.3 | Integer32 | read-only | current |
| optIfOChSrcCurrentHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the current 15-minute interval. | 1.3.6.1.2.1.10.133.1.6.6.1.4 | Integer32 | read-only | current |
| optIfOChSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE The lower limit threshold on output power. If optIfOChSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.6.6.1.5 | Integer32 | read-write | current |
| optIfOChSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE The upper limit threshold on output power. If optIfOChSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. | 1.3.6.1.2.1.10.133.1.6.6.1.6 | Integer32 | read-write | current |
| optIfOChSrcIntervalTable OBJECT-TYPE A table of historical OCh source performance monitoring information. | 1.3.6.1.2.1.10.133.1.6.7 | not-accessible | current | |
| optIfOChSrcIntervalEntry OBJECT-TYPE A conceptual row that contains OCh source performance monitoring information of an interface during a particular historical interval. | 1.3.6.1.2.1.10.133.1.6.7.1 | not-accessible | current | |
| optIfOChSrcIntervalNumber OBJECT-TYPE Uniquely identifies the interval. | 1.3.6.1.2.1.10.133.1.6.7.1.1 | OptIfIntervalNumber | not-accessible | current |
| optIfOChSrcIntervalSuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.6.7.1.2 | TruthValue | read-only | current |
| optIfOChSrcIntervalLastOutputPower OBJECT-TYPE The last optical power monitored at the output during the interval. | 1.3.6.1.2.1.10.133.1.6.7.1.3 | Integer32 | read-only | current |
| optIfOChSrcIntervalLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the interval. | 1.3.6.1.2.1.10.133.1.6.7.1.4 | Integer32 | read-only | current |
| optIfOChSrcIntervalHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the interval. | 1.3.6.1.2.1.10.133.1.6.7.1.5 | Integer32 | read-only | current |
| optIfOChSrcCurDayTable OBJECT-TYPE A table of OCh source performance monitoring information for the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.8 | not-accessible | current | |
| optIfOChSrcCurDayEntry OBJECT-TYPE A conceptual row that contains OCh source performance monitoring information of an interface for the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.8.1 | not-accessible | current | |
| optIfOChSrcCurDaySuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.6.8.1.1 | TruthValue | read-only | current |
| optIfOChSrcCurDayLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.8.1.2 | Integer32 | read-only | current |
| optIfOChSrcCurDayHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the current 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.8.1.3 | Integer32 | read-only | current |
| optIfOChSrcPrevDayTable OBJECT-TYPE A table of OCh source performance monitoring information for the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.9 | not-accessible | current | |
| optIfOChSrcPrevDayEntry OBJECT-TYPE A conceptual row that contains OCh source performance monitoring information of an interface for the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.9.1 | not-accessible | current | |
| optIfOChSrcPrevDaySuspectedFlag OBJECT-TYPE If true, the data in this entry may be unreliable. | 1.3.6.1.2.1.10.133.1.6.9.1.1 | TruthValue | read-only | current |
| optIfOChSrcPrevDayLastOutputPower OBJECT-TYPE The last optical power monitored at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.9.1.2 | Integer32 | read-only | current |
| optIfOChSrcPrevDayLowOutputPower OBJECT-TYPE The lowest optical power monitored at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.9.1.3 | Integer32 | read-only | current |
| optIfOChSrcPrevDayHighOutputPower OBJECT-TYPE The highest optical power monitored at the output during the previous 24-hour interval. | 1.3.6.1.2.1.10.133.1.6.9.1.4 | Integer32 | read-only | current |
| optIfOTUk OBJECT-IDENTITY | 1.3.6.1.2.1.10.133.1.7 | |||
| optIfOTUkConfigTable OBJECT-TYPE A table of OTUk configuration information. | 1.3.6.1.2.1.10.133.1.7.1 | not-accessible | current | |
| optIfOTUkConfigEntry OBJECT-TYPE A conceptual row that contains OTUk configuration information of an interface. | 1.3.6.1.2.1.10.133.1.7.1.1 | not-accessible | current | |
| optIfOTUkDirectionality OBJECT-TYPE Indicates the directionality of the entity. | 1.3.6.1.2.1.10.133.1.7.1.1.1 | OptIfDirectionality | read-only | current |
| optIfOTUkBitRateK OBJECT-TYPE Indicates the bit rate of the entity. | 1.3.6.1.2.1.10.133.1.7.1.1.2 | OptIfBitRateK | read-only | current |
| optIfOTUkTraceIdentifierTransmitted OBJECT-TYPE The trace identifier transmitted. This object is applicable when optIfOTUkDirectionality has the value source(2) or bidirectional(3). It must not be instantiated in rows where optIfOTUkDirectionality has the value sink(1). If no value is ever set by a management entity for this object, system-specific default value will be used. Any implementation that instantiates this object must document the system-specific default value or how it is derived. | 1.3.6.1.2.1.10.133.1.7.1.1.3 | OptIfTxTI | read-write | current |
| optIfOTUkDAPIExpected OBJECT-TYPE The DAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfOTUkDirectionality has the value source(2). This object has no effect when optIfOTUkTIMDetMode has the value off(1). | 1.3.6.1.2.1.10.133.1.7.1.1.4 | OptIfExDAPI | read-write | current |
| optIfOTUkSAPIExpected OBJECT-TYPE The SAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfOTUkDirectionality has the value source(2). This object has no effect when optIfOTUkTIMDetMode has the value off(1). | 1.3.6.1.2.1.10.133.1.7.1.1.5 | OptIfExSAPI | read-write | current |
| optIfOTUkTraceIdentifierAccepted OBJECT-TYPE The actual trace identifier accepted. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfOTUkDirectionality has the value source(2). The value of this object is unspecified when optIfOTUkCurrentStatus indicates a near-end defect (i.e., ssf(3), lof(4), ais(5), lom(6)) that prevents extraction of the trace message. | 1.3.6.1.2.1.10.133.1.7.1.1.6 | OptIfAcTI | read-only | current |
| optIfOTUkTIMDetMode OBJECT-TYPE Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfOTUkDirectionality has the value source(2). The default value of this object is off(1). | 1.3.6.1.2.1.10.133.1.7.1.1.7 | OptIfTIMDetMode | read-write | current |
| optIfOTUkTIMActEnabled OBJECT-TYPE Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfOTUkDirectionality has the value source(2). This object has no effect when optIfOTUkTIMDetMode has the value off(1). The default value of this object is false(2). | 1.3.6.1.2.1.10.133.1.7.1.1.8 | TruthValue | read-write | current |
| optIfOTUkDEGThr OBJECT-TYPE Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to optIfOTUkDEGThr. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfOTUkDirectionality has the value source(2). The default value of this object is Severely Errored Second (SES) Estimator (See ITU-T G.7710). | 1.3.6.1.2.1.10.133.1.7.1.1.9 | OptIfDEGThr | read-write | current |
| optIfOTUkDEGM OBJECT-TYPE Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if optIfOTUkDEGM consecutive bad PM Seconds are detected. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfOTUkDirectionality has the value source(2). The default value of this object is 7 (See ITU-T G.7710). | 1.3.6.1.2.1.10.133.1.7.1.1.10 | OptIfDEGM | read-write | current |
| optIfOTUkSinkAdaptActive OBJECT-TYPE Indicates whether the sink adaptation function is activated or not. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfOTUkDirectionality has the value source(2). The default value of this object is false(2). | 1.3.6.1.2.1.10.133.1.7.1.1.11 | TruthValue | read-write | current |
| optIfOTUkSourceAdaptActive OBJECT-TYPE Indicates whether the source adaptation function is activated or not. This object is only applicable to the source function, i.e., only when optIfOTUkDirectionality has the value source(2) or bidirectional(3). It must not be instantiated in rows where optIfOTUkDirectionality has the value sink(1). The default value of this object is false(2). | 1.3.6.1.2.1.10.133.1.7.1.1.12 | TruthValue | read-write | current |
| optIfOTUkSinkFECEnabled OBJECT-TYPE If Forward Error Correction (FEC) is supported, this object indicates whether FEC at the OTUk sink adaptation function is enabled or not. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfOTUkDirectionality has the value source(2). The default value of this object is true(1). | 1.3.6.1.2.1.10.133.1.7.1.1.13 | TruthValue | read-write | current |
| optIfOTUkCurrentStatus OBJECT-TYPE Indicates the defect condition of the entity, if any. This object is only applicable to the sink function, i.e., only when optIfOTUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfOTUkDirectionality has the value source(2). | 1.3.6.1.2.1.10.133.1.7.1.1.14 | Bits {tim(0), deg(1), bdi(2), ssf(3), lof(4), ais(5), lom(6)} | read-only | current |
| optIfGCC0ConfigTable OBJECT-TYPE A table of GCC0 configuration information. | 1.3.6.1.2.1.10.133.1.7.2 | not-accessible | current | |
| optIfGCC0ConfigEntry OBJECT-TYPE A conceptual row that contains GCC0 configuration information of an interface. Each instance must correspond to an instance of optIfOTUkConfigEntry. Separate source and/or sink instances may exist for a given ifIndex value, or a single bidirectional instance may exist, but a bidirectional instance may not coexist with a source or sink instance. Instances of this conceptual row persist across agent restarts. | 1.3.6.1.2.1.10.133.1.7.2.1 | not-accessible | current | |
| optIfGCC0Directionality OBJECT-TYPE Indicates the directionality of the entity. The values source(2) and bidirectional(3) are not allowed if the corresponding instance of optIfOTUkDirectionality has the value sink(1). The values sink(1) and bidirectional(3) are not allowed if the corresponding instance of optIfOTUkDirectionality has the value source(2). | 1.3.6.1.2.1.10.133.1.7.2.1.1 | OptIfDirectionality | not-accessible | current |
| optIfGCC0Application OBJECT-TYPE Indicates the application transported by the GCC0 entity. Example applications are ECC, User data channel. The value of this object may not be changed when optIfGCC0RowStatus has the value active(1). | 1.3.6.1.2.1.10.133.1.7.2.1.2 | SnmpAdminString | read-create | current |
| optIfGCC0RowStatus OBJECT-TYPE This columnar object is used for creating and deleting a conceptual row of the optIfGCC0 config table. It is used to model the addGCC0Access and removeGCC0Access operations of an OTUk_TTP for GCC0 access control as defined in G.874.1. Setting RowStatus to createAndGo or createAndWait implies addGCC0Access. Setting RowStatus to destroy implies removeGCC0Access. | 1.3.6.1.2.1.10.133.1.7.2.1.3 | RowStatus | read-create | current |
| optIfODUk OBJECT-IDENTITY | 1.3.6.1.2.1.10.133.1.8 | |||
| optIfODUkConfigTable OBJECT-TYPE A table of ODUk configuration information. | 1.3.6.1.2.1.10.133.1.8.1 | not-accessible | current | |
| optIfODUkConfigEntry OBJECT-TYPE A conceptual row that contains ODUk configuration information of an interface. | 1.3.6.1.2.1.10.133.1.8.1.1 | not-accessible | current | |
| optIfODUkDirectionality OBJECT-TYPE Indicates the directionality of the entity. | 1.3.6.1.2.1.10.133.1.8.1.1.1 | OptIfDirectionality | read-only | current |
| optIfODUkBitRateK OBJECT-TYPE Indicates the bit rate of the entity. | 1.3.6.1.2.1.10.133.1.8.1.1.2 | OptIfBitRateK | read-only | current |
| optIfODUkTcmFieldsInUse OBJECT-TYPE Indicates the TCM field(s) that are currently in use. The positions of the bits correspond to the TCM fields. A bit that is set to 1 means that the corresponding TCM field is used. This object will be updated when rows are created in or deleted from the optIfODUkTConfigTable, or the optIfODUkTNimConfigTable. | 1.3.6.1.2.1.10.133.1.8.1.1.3 | Bits {tcmField1(0), tcmField2(1), tcmField3(2), tcmField4(3), tcmField5(4), tcmField6(5)} | read-only | current |
| optIfODUkPositionSeqCurrentSize OBJECT-TYPE This variable indicates the current size of the position sequence (i.e., number of TCM function and/or GCC12 access that have been created in the ODUk interface). When the value of this variable is greater than zero, it means that one or more TCM function and/or GCC12 access have been created in the ODUk interface. In this case, there will be as many rows in the optIfODUkPositionSeqTable as the value of optIfODUkPositionSeqCurrentSize corresponding to this ODUk interface, one row for each TCM function or GCC12 access. The position of the TCM function and/or GCC12 access within the sequence is indicated by the optIfODUkPositionSeqPosition variable in optIfODUkPositionSeqTable. The optIfODUkPositionSeqTable also provides pointers to the corresponding TCM function (optIfODUkT) and GCC12 access (optIfGCC12) entities. | 1.3.6.1.2.1.10.133.1.8.1.1.4 | Unsigned32 | read-only | current |
| optIfODUkTtpPresent OBJECT-TYPE This object has the value true(1) if the ifEntry under which it is instantiated contains an ODUk Trail Termination Point, i.e., is the endpoint of an ODUk path. In that case there will be a corresponding row in the ODUk TTP config table and it will not be possible to create corresponding rows in the ODUk NIM config table. This object has the value false(2) if the ifEntry under which it is instantiated contains an intermediate ODUk Connection Termination Point. In that case there is no corresponding row in the ODUk TTP config table, but it will be possible to create corresponding rows in the ODUk NIM config table. This object also affects the allowable options in rows created in the GCC12 config table and in the ODUkT config table, as specified in the DESCRIPTION clauses of the columns in those tables. | 1.3.6.1.2.1.10.133.1.8.1.1.5 | TruthValue | read-only | current |
| optIfODUkTtpConfigTable OBJECT-TYPE A table of ODUk TTP configuration information. | 1.3.6.1.2.1.10.133.1.8.2 | not-accessible | current | |
| optIfODUkTtpConfigEntry OBJECT-TYPE A conceptual row that contains ODUk TTP configuration information of an interface. | 1.3.6.1.2.1.10.133.1.8.2.1 | not-accessible | current | |
| optIfODUkTtpTraceIdentifierTransmitted OBJECT-TYPE The trace identifier transmitted. This object is applicable when optIfODUkDirectionality has the value source(2) or bidirectional(3). It must not be instantiated in rows where optIfODUkDirectionality has the value sink(1). If no value is ever set by a management entity for this object, system-specific default value will be used. Any implementation that instantiates this object must document the system-specific default value or how it is derived. | 1.3.6.1.2.1.10.133.1.8.2.1.1 | OptIfTxTI | read-write | current |
| optIfODUkTtpDAPIExpected OBJECT-TYPE The DAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfODUkDirectionality has the value source(2). This object has no effect when optIfODUkTtpTIMDetMode has the value off(1). | 1.3.6.1.2.1.10.133.1.8.2.1.2 | OptIfExDAPI | read-write | current |
| optIfODUkTtpSAPIExpected OBJECT-TYPE The SAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfODUkDirectionality has the value source(2). This object has no effect when optIfODUkTtpTIMDetMode has the value off(1). | 1.3.6.1.2.1.10.133.1.8.2.1.3 | OptIfExSAPI | read-write | current |
| optIfODUkTtpTraceIdentifierAccepted OBJECT-TYPE The actual trace identifier accepted. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfODUkDirectionality has the value source(2). The value of this object is unspecified when optIfODUkTtpCurrentStatus indicates a near-end defect (i.e., oci(0), lck(1), ssf(5)) that prevents extraction of the trace message. | 1.3.6.1.2.1.10.133.1.8.2.1.4 | OptIfAcTI | read-only | current |
| optIfODUkTtpTIMDetMode OBJECT-TYPE Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfODUkDirectionality has the value source(2). The default value of this object is off(1). | 1.3.6.1.2.1.10.133.1.8.2.1.5 | OptIfTIMDetMode | read-write | current |
| optIfODUkTtpTIMActEnabled OBJECT-TYPE Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfODUkDirectionality has the value source(2). This object has no effect when optIfODUkTtpTIMDetMode has the value off(1). The default value of this object is false(2). | 1.3.6.1.2.1.10.133.1.8.2.1.6 | TruthValue | read-write | current |
| optIfODUkTtpDEGThr OBJECT-TYPE Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to optIfODUkDEGThr. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfODUkDirectionality has the value source(2). The default value of this object is Severely Errored Second (SES) Estimator (See ITU-T G.7710). | 1.3.6.1.2.1.10.133.1.8.2.1.7 | OptIfDEGThr | read-write | current |
| optIfODUkTtpDEGM OBJECT-TYPE Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if optIfODUkDEGM consecutive bad PM Seconds are detected. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfODUkDirectionality has the value source(2). The default value of this object is 7 (See ITU-T G.7710). | 1.3.6.1.2.1.10.133.1.8.2.1.8 | OptIfDEGM | read-write | current |
| optIfODUkTtpCurrentStatus OBJECT-TYPE Indicates the defect condition of the entity, if any. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfODUkDirectionality has the value source(2). | 1.3.6.1.2.1.10.133.1.8.2.1.9 | Bits {oci(0), lck(1), tim(2), deg(3), bdi(4), ssf(5)} | read-only | current |
| optIfODUkPositionSeqTable OBJECT-TYPE A table of ODUk Position Sequence information. | 1.3.6.1.2.1.10.133.1.8.3 | not-accessible | current | |
| optIfODUkPositionSeqEntry OBJECT-TYPE A conceptual row that contains ODUk position sequence information of an ODUk interface. The ODUk interface is identified by the ifIndex. Associated with each ODUk interface there may be one of more conceptual rows in the optIfODUkPositionSeqTable. Each row represents a TCM or GCC12 access function within the associated ODUk interface. Rows of the optIfODUkPositionSeqTable table are created/deleted as the result of the creation/deletion of the optIfODUkT or optIfGCC12 entities. | 1.3.6.1.2.1.10.133.1.8.3.1 | not-accessible | current | |
| optIfODUkPositionSeqIndex OBJECT-TYPE This variable identifies a row in the optIfODUkPositionSeqTable Table. Each row of the optIfODUkPositionSeqTable Table represents a TCM or GCC12 access function within the associated ODUk interface. | 1.3.6.1.2.1.10.133.1.8.3.1.1 | Unsigned32 (1..4294967295) | not-accessible | current |
| optIfODUkPositionSeqPosition OBJECT-TYPE This variable indicates the position of the TCM or GCC12 access function within the sequence of TCMs & GCC12 access functions of the associated ODUk interface. The TCM or GCC12 presented by this row is referenced by the optIfODUkPositionSeqPointer variable. | 1.3.6.1.2.1.10.133.1.8.3.1.2 | Unsigned32 | read-only | current |
| optIfODUkPositionSeqPointer OBJECT-TYPE This variable identifies the TCM or GCC12 access function by pointing to the corresponding optIfODUkT or optIfGCC12 entity. | 1.3.6.1.2.1.10.133.1.8.3.1.3 | RowPointer | read-only | current |
| optIfODUkNimConfigTable OBJECT-TYPE A table of ODUkNim configuration information. | 1.3.6.1.2.1.10.133.1.8.4 | not-accessible | current | |
| optIfODUkNimConfigEntry OBJECT-TYPE A conceptual row that contains ODUkNim configuration information of an interface. Each instance must correspond to an instance of optIfODUkConfigEntry for which optIfODUkTtpPresent has the value false(2). Instances of this conceptual row persist across agent restarts, and read-create columns other than the status column may be modified while the row is active. | 1.3.6.1.2.1.10.133.1.8.4.1 | not-accessible | current | |
| optIfODUkNimDirectionality OBJECT-TYPE Specifies the monitor point for the ODUk Path non-intrusive monitoring function. The value source(2) is not allowed if the corresponding instance of optIfODUkDirectionality has the value sink(1), and the value sink(1) is not allowed if the corresponding instance of optIfODUkDirectionality has the value source(2). Either the value sink(1) or source(2) is allowed if the corresponding instance of optIfODUkDirectionality has the value bidirectional(3). The value sink(1) means monitoring at the sink direction path signal of the ODUk CTP. The value source(2) means monitoring at the source direction path signal of the ODUk CTP. Monitoring the source direction of an ODUk CTP is necessary in those cases where the ODUk CTP is at an SNCP (Subnetwork Connection Protection) end (e.g., see Figure I.1.2/G.874.1). If one would like to get the performance of the protected connection, one cannot use the NIM function at both ODUk CTP sinks (before the matrix), instead one should monitor the signal at the source ODUk CTP after the matrix. | 1.3.6.1.2.1.10.133.1.8.4.1.1 | OptIfSinkOrSource | not-accessible | current |
| optIfODUkNimDAPIExpected OBJECT-TYPE The DAPI expected by the receiver. This object has no effect if optIfODUkNimTIMDetMode has the value off(1) or sapi(3). | 1.3.6.1.2.1.10.133.1.8.4.1.2 | OptIfExDAPI | read-create | current |
| optIfODUkNimSAPIExpected OBJECT-TYPE The SAPI expected by the receiver. This object has no effect if optIfODUkNimTIMDetMode has the value off(1) or dapi(2). | 1.3.6.1.2.1.10.133.1.8.4.1.3 | OptIfExSAPI | read-create | current |
| optIfODUkNimTraceIdentifierAccepted OBJECT-TYPE The actual trace identifier accepted. The value of this object is unspecified if optIfODUkNimCurrentStatus has any of the bit positions oci(0), lck(1), or ssf(5) set or if optIfODUkNimRowStatus has any value other than active(1). | 1.3.6.1.2.1.10.133.1.8.4.1.4 | OptIfAcTI | read-only | current |
| optIfODUkNimTIMDetMode OBJECT-TYPE Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. | 1.3.6.1.2.1.10.133.1.8.4.1.5 | OptIfTIMDetMode | read-create | current |
| optIfODUkNimTIMActEnabled OBJECT-TYPE Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. | 1.3.6.1.2.1.10.133.1.8.4.1.6 | TruthValue | read-create | current |
| optIfODUkNimDEGThr OBJECT-TYPE Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to optIfODUkNimDEGThr. | 1.3.6.1.2.1.10.133.1.8.4.1.7 | OptIfDEGThr | read-create | current |
| optIfODUkNimDEGM OBJECT-TYPE Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if optIfODUkNimDEGM consecutive bad PM Seconds are detected. | 1.3.6.1.2.1.10.133.1.8.4.1.8 | OptIfDEGM | read-create | current |
| optIfODUkNimCurrentStatus OBJECT-TYPE Indicates the defect condition of the entity, if any. The value of this object is unspecified if optIfODUkNimRowStatus has any value other than active(1). | 1.3.6.1.2.1.10.133.1.8.4.1.9 | Bits {oci(0), lck(1), tim(2), deg(3), bdi(4), ssf(5)} | read-only | current |
| optIfODUkNimRowStatus OBJECT-TYPE This columnar object is used for creating and deleting a conceptual row of the optIfODUkNim config table. It is used to model the activateNim and deactivateNim operations of an OTUk_CTP for non-intrusive monitoring control as defined in G.874.1. Setting RowStatus to createAndGo or createAndWait implies activateNim. Setting RowStatus to destroy implies deactivateNim. | 1.3.6.1.2.1.10.133.1.8.4.1.10 | RowStatus | read-create | current |
| optIfGCC12ConfigTable OBJECT-TYPE A table of GCC12 configuration information. The GCC function processes the GCC overhead bytes passing through them but leave the remainder of the ODUk overhead and payload data alone. | 1.3.6.1.2.1.10.133.1.8.5 | not-accessible | current | |
| optIfGCC12ConfigEntry OBJECT-TYPE A conceptual row that contains GCC12 configuration information of an interface. Each instance must correspond to an instance of optIfODUkConfigEntry. Separate instances providing GCC1-only access and GCC2-only access may exist for a given ifIndex value, or a single instance providing GCC1 + GCC2 may exist, but a GCC1 + GCC2 instance may not coexist with a GCC1-only or GCC2-only instance. Instances of this conceptual row persist across agent restarts. | 1.3.6.1.2.1.10.133.1.8.5.1 | not-accessible | current | |
| optIfGCC12Codirectional OBJECT-TYPE Indicates the directionality of the GCC12 termination with respect to the associated ODUk CTP. The value true(1) means that the sink part of the GCC12 extracts COMMS data from the signal at the input to the ODUk CTP sink and the source part of the GCC12 inserts COMMS data into the signal at the output of the ODUk CTP source. The value false(2) means that the sink part of the GCC12 extracts COMMS data from the signal at the output of the ODUk CTP source and the source part of the GCC12 inserts COMMS data into the signal at the input of the ODUk CTP sink. This attribute may assume either value when the corresponding instance of optIfODUkTtpPresent has the value false(2). When the value of the corresponding instance of optIfODUkTtpPresent is true(1) then the only value allowed for this attribute is true(1). | 1.3.6.1.2.1.10.133.1.8.5.1.1 | TruthValue | not-accessible | current |
| optIfGCC12GCCAccess OBJECT-TYPE Indicates the GCC access represented by the entity. | 1.3.6.1.2.1.10.133.1.8.5.1.2 | INTEGER {gcc1(1), gcc2(2), gcc1and2(3)} | not-accessible | current |
| optIfGCC12GCCPassThrough OBJECT-TYPE Controls whether the selected GCC overhead bytes are passed through or modified. The value true(1) means that the selected GCC overhead bytes are passed through unmodified from the ODUk CTP input to the ODUk CTP output. The value false(2) means that the selected GCC overhead bytes are set to zero at the ODUk CTP output after the extraction of the COMMS data. This object has no effect if the corresponding instance of optIfODUkTtpPresent has the value true(1). The value of this object may not be changed when optIfGCC12RowStatus has the value active(1). | 1.3.6.1.2.1.10.133.1.8.5.1.3 | TruthValue | read-create | current |
| optIfGCC12Application OBJECT-TYPE Indicates the application transported by the GCC12 entity. Example applications are ECC, User data channel. The value of this object may not be changed when optIfGCC12RowStatus has the value active(1). | 1.3.6.1.2.1.10.133.1.8.5.1.4 | SnmpAdminString | read-create | current |
| optIfGCC12RowStatus OBJECT-TYPE This columnar object is used for creating and deleting a conceptual row of the optIfGCC12 config table. It is used to model the addGCC12Access and removeGCC12Access operations of an ODUk_CTP or ODUk_TTP for GCC12 access control as defined in G.874.1. Setting RowStatus to createAndGo or createAndWait implies addGCC12Access. Setting RowStatus to destroy implies removeGCC12Access. Successful addition/removal of the GCC12 access function will result in updating the optIfODUkPositionSeqCurrentSize variable and the optIfODUkPositionSeqTable table of the associated ODUk entry in the optIfODUkConfigTable. | 1.3.6.1.2.1.10.133.1.8.5.1.5 | RowStatus | read-create | current |
| optIfODUkT OBJECT-IDENTITY | 1.3.6.1.2.1.10.133.1.9 | |||
| optIfODUkTConfigTable OBJECT-TYPE A table of ODUkT configuration information. | 1.3.6.1.2.1.10.133.1.9.1 | not-accessible | current | |
| optIfODUkTConfigEntry OBJECT-TYPE A conceptual row that contains ODUkT configuration information of an interface. Each instance must correspond to an instance of optIfODUkConfigEntry. Rows in this table are mutually exclusive with rows in the ODUkT NIM config table -- in other words, this row object may not be instantiated for a given pair of ifIndex and TCM field values if a corresponding instance of optIfODUkTNimConfigEntry already exists. Instances of this conceptual row persist across agent restarts. Except where noted otherwise, read-create columns other than the status column may be modified while the row is active. | 1.3.6.1.2.1.10.133.1.9.1.1 | not-accessible | current | |
| optIfODUkTTcmField OBJECT-TYPE Indicates the tandem connection monitoring field of the ODUk OH. Valid values are integers from 1 to 6. | 1.3.6.1.2.1.10.133.1.9.1.1.1 | Unsigned32 (1..6) | not-accessible | current |
| optIfODUkTCodirectional OBJECT-TYPE Indicates the directionality of the ODUkT termination point with respect to the associated ODUk CTP. The value true(1) means that the sink part of the ODUkT TP extracts TCM data from the signal at the input to the ODUk CTP sink and the source part of the ODUkT TP inserts TCM data into the signal at the output of the ODUk CTP source. The value false(2) means that the sink part of the ODUkT TP extracts TCM data from the signal at the output of the ODUk CTP source and the source part of the ODUkT TP inserts TCM data into the signal at the input of the ODUk CTP sink. This attribute may assume either value when the corresponding instance of optIfODUkTtpPresent has the value false(2). When the value of the corresponding instance of optIfODUkTtpPresent is true(1) then the only value allowed for this attribute is true(1). | 1.3.6.1.2.1.10.133.1.9.1.1.2 | TruthValue | not-accessible | current |
| optIfODUkTTraceIdentifierTransmitted OBJECT-TYPE The trace identifier transmitted. This object is applicable only to the following three cases. (i) optIfODUkDirectionality has the value bidirectional(3), or (ii) optIfODUkDirectionality has the value sink(1) and optIfODUkTCodirectional has the value false(2), or (iii) optIfODUkDirectionality has the value source(3) and optIfODUkTCodirectional has the value true(1). It must not be instantiated in rows for all other cases. | 1.3.6.1.2.1.10.133.1.9.1.1.3 | OptIfTxTI | read-create | current |
| optIfODUkTDAPIExpected OBJECT-TYPE The DAPI expected by the receiver. This object is applicable only to the following three cases. (i) optIfODUkDirectionality has the value bidirectional(3), or (ii) optIfODUkDirectionality has the value sink(1) and optIfODUkTCodirectional has the value true(1), or (iii) optIfODUkDirectionality has the value source(3) and optIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. This object has no effect when optIfODUkTTIMDetMode has the value off(1). | 1.3.6.1.2.1.10.133.1.9.1.1.4 | OptIfExDAPI | read-create | current |
| optIfODUkTSAPIExpected OBJECT-TYPE The SAPI expected by the receiver. This object is applicable only to the following three cases. (i) optIfODUkDirectionality has the value bidirectional(3), or (ii) optIfODUkDirectionality has the value sink(1) and optIfODUkTCodirectional has the value true(1), or (iii) optIfODUkDirectionality has the value source(3) and optIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. This object has no effect when optIfODUkTTIMDetMode has the value off(1). | 1.3.6.1.2.1.10.133.1.9.1.1.5 | OptIfExSAPI | read-create | current |
| optIfODUkTTraceIdentifierAccepted OBJECT-TYPE The actual trace identifier accepted. This object is applicable only to the following three cases. (i) optIfODUkDirectionality has the value bidirectional(3), or (ii) optIfODUkDirectionality has the value sink(1) and optIfODUkTCodirectional has the value true(1), or (iii) optIfODUkDirectionality has the value source(3) and optIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. The value of this object is unspecified when optIfODUkTCurrentStatus indicates a near-end defect (i.e., oci(0), lck(1), ssf(5)) that prevents extraction of the trace message. | 1.3.6.1.2.1.10.133.1.9.1.1.6 | OptIfAcTI | read-only | current |
| optIfODUkTTIMDetMode OBJECT-TYPE Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is applicable only to the following three cases. (i) optIfODUkDirectionality has the value bidirectional(3), or (ii) optIfODUkDirectionality has the value sink(1) and optIfODUkTCodirectional has the value true(1), or (iii) optIfODUkDirectionality has the value source(3) and optIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. The default value of this object is off(1). | 1.3.6.1.2.1.10.133.1.9.1.1.7 | OptIfTIMDetMode | read-create | current |
| optIfODUkTTIMActEnabled OBJECT-TYPE Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is applicable only to the following three cases. (i) optIfODUkDirectionality has the value bidirectional(3), or (ii) optIfODUkDirectionality has the value sink(1) and optIfODUkTCodirectional has the value true(1), or (iii) optIfODUkDirectionality has the value source(3) and optIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. This object has no effect when optIfODUkTTIMDetMode has the value off(1). The default value of this object is false(2). | 1.3.6.1.2.1.10.133.1.9.1.1.8 | TruthValue | read-create | current |
| optIfODUkTDEGThr OBJECT-TYPE Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to optIfODUkTDEGThr. This object is applicable only to the following three cases. (i) optIfODUkDirectionality has the value bidirectional(3), or (ii) optIfODUkDirectionality has the value sink(1) and optIfODUkTCodirectional has the value true(1), or (iii) optIfODUkDirectionality has the value source(3) and optIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. The default value of this object is Severely Errored Second (SES) Estimator (See ITU-T G.7710). | 1.3.6.1.2.1.10.133.1.9.1.1.9 | OptIfDEGThr | read-create | current |
| optIfODUkTDEGM OBJECT-TYPE Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if optIfODUkTDEGM consecutive bad PM Seconds are detected. This object is applicable only to the following three cases. (i) optIfODUkDirectionality has the value bidirectional(3), or (ii) optIfODUkDirectionality has the value sink(1) and optIfODUkTCodirectional has the value true(1), or (iii) optIfODUkDirectionality has the value source(3) and optIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. The default value of this object is 7 (See ITU-T G.7710). | 1.3.6.1.2.1.10.133.1.9.1.1.10 | OptIfDEGM | read-create | current |
| optIfODUkTSinkMode OBJECT-TYPE This variable specifies the TCM mode at the entity. The value operational(1) means that TCM Overhead (TCMOH) processes (see ITU-T G.798) shall be performed and consequent actions for AIS, Trail Signal Fail (TSF), Trail Signal Degraded (TSD) shall be initiated in case of defects. The value monitor(2) means that TCMOH processes shall be performed but consequent actions for AIS, Trail Server Failure (TSF), Trail Server Degraded (TSD) shall _not_ be initiated in case of defects. This object is applicable only when the value of optIfODUkTtpPresent is false(2) and also either one of the following three cases holds: (i) optIfODUkDirectionality has the value bidirectional(3), or (ii) optIfODUkDirectionality has the value sink(1) and optIfODUkTCodirectional has the value true(1), or (iii) optIfODUkDirectionality has the value source(3) and optIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. | 1.3.6.1.2.1.10.133.1.9.1.1.11 | INTEGER {operational(1), monitor(2)} | read-create | current |
| optIfODUkTSinkLockSignalAdminState OBJECT-TYPE Provides the capability to provision the LOCK signal, which is one of the ODUk maintenance signals, at the ODUKT sink. When a Tandem Connection endpoint is set to admin state locked, it inserts the ODUk-LCK signal in the sink direction. This object is applicable only when the value of optIfODUkTtpPresent is false(2) and also either one of the following three cases holds: (i) optIfODUkDirectionality has the value bidirectional(3), or (ii) optIfODUkDirectionality has the value sink(1) and optIfODUkTCodirectional has the value true(1), or (iii) optIfODUkDirectionality has the value source(3) and optIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. | 1.3.6.1.2.1.10.133.1.9.1.1.12 | INTEGER {locked(1), normal(2)} | read-create | current |
| optIfODUkTSourceLockSignalAdminState OBJECT-TYPE Provides the capability to provision the LOCK signal, which is one of the ODUk maintenance signals, at the source. When a Tandem Connection endpoint is set to admin state locked, it inserts the ODUk-LCK signal in the source direction. This object is applicable only when either one of the following three cases holds: (i) optIfODUkDirectionality has the value bidirectional(3), or (ii) optIfODUkDirectionality has the value sink(1) and optIfODUkTCodirectional has the value false(2), or (iii) optIfODUkDirectionality has the value source(3) and optIfODUkTCodirectional has the value true(1). It must not be instantiated in rows for all other cases. | 1.3.6.1.2.1.10.133.1.9.1.1.13 | INTEGER {locked(1), normal(2)} | read-create | current |
| optIfODUkTCurrentStatus OBJECT-TYPE Indicates the defect condition of the entity, if any. This object is applicable only when either one of the following three cases holds: (i) optIfODUkDirectionality has the value bidirectional(3), or (ii) optIfODUkDirectionality has the value sink(1) and optIfODUkTCodirectional has the value true(1), or (iii) optIfODUkDirectionality has the value source(3) and optIfODUkTCodirectional has the value false(2). It must not be instantiated in rows for all other cases. | 1.3.6.1.2.1.10.133.1.9.1.1.14 | Bits {oci(0), lck(1), tim(2), deg(3), bdi(4), ssf(5)} | read-only | current |
| optIfODUkTRowStatus OBJECT-TYPE This columnar object is used for creating and deleting a conceptual row of the optIfODUkT config table. It is used to model the addTCM and removeTCM operations of an ODUk_CTP or ODUk_TTP for Tandem connection monitoring as defined in ITU-T G.874.1. Setting RowStatus to createAndGo or createAndWait implies addTCM. Setting RowStatus to destroy implies removeTCM. Successful addition/removal of TCM will result in updating the optIfODUkTcmFieldsInUse and optIfODUkPositionSeqCurrentSize variables and the optIfODUkPositionSeqTable table of the associated ODUk entry in the optIfODUkConfigTable. | 1.3.6.1.2.1.10.133.1.9.1.1.15 | RowStatus | read-create | current |
| optIfODUkTNimConfigTable OBJECT-TYPE A table of ODUkTNim configuration information. | 1.3.6.1.2.1.10.133.1.9.2 | not-accessible | current | |
| optIfODUkTNimConfigEntry OBJECT-TYPE A conceptual row that contains ODUkTNim configuration information of an interface. Each instance must correspond to an instance of optIfODUkConfigEntry. Rows in this table are mutually exclusive with rows in the ODUkT config table -- in other words, this row object may not be instantiated for a given pair of ifIndex and TCM field values if a corresponding instance of optIfODUkTConfigEntry already exists. Instances of this conceptual row persist across agent restarts, and read-create columns other than the status column may be modified while the row is active. | 1.3.6.1.2.1.10.133.1.9.2.1 | not-accessible | current | |
| optIfODUkTNimTcmField OBJECT-TYPE Indicates the tandem connection monitoring field of the ODUk OH on which non-intrusive monitoring is performed. Valid values are integers from 1 to 6. | 1.3.6.1.2.1.10.133.1.9.2.1.1 | Unsigned32 (1..6) | not-accessible | current |
| optIfODUkTNimDirectionality OBJECT-TYPE Specifies the monitor point for the ODUk TCM non-intrusive monitoring function. The value source(2) is not allowed if the corresponding instance of optIfODUkDirectionality has the value sink(1), and the value sink(1) is not allowed if the corresponding instance of optIfODUkDirectionality has the value source(2). Either the value sink(1) or source(2) is allowed if the corresponding instance of optIfODUkDirectionality has the value bidirectional(3). The value sink(1) means monitoring at the sink direction TCM signal of the ODUk CTP. The value source(2) means monitoring at the source direction path signal of the ODUk CTP. | 1.3.6.1.2.1.10.133.1.9.2.1.2 | OptIfSinkOrSource | not-accessible | current |
| optIfODUkTNimDAPIExpected OBJECT-TYPE The DAPI expected by the receiver. This object has no effect if optIfODUkTNimTIMDetMode has the value off(1) or sapi(3). | 1.3.6.1.2.1.10.133.1.9.2.1.3 | OptIfExDAPI | read-create | current |
| optIfODUkTNimSAPIExpected OBJECT-TYPE The SAPI expected by the receiver. This object has no effect if optIfODUkTNimTIMDetMode has the value off(1) or dapi(2). | 1.3.6.1.2.1.10.133.1.9.2.1.4 | OptIfExSAPI | read-create | current |
| optIfODUkTNimTraceIdentifierAccepted OBJECT-TYPE The actual trace identifier accepted. The value of this object is unspecified if optIfODUkTNimCurrentStatus has any of the bit positions oci(0), lck(1), or ssf(5) set or if optIfODUkTNimRowStatus has any value other than active(1). | 1.3.6.1.2.1.10.133.1.9.2.1.5 | OptIfAcTI | read-only | current |
| optIfODUkTNimTIMDetMode OBJECT-TYPE Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. | 1.3.6.1.2.1.10.133.1.9.2.1.6 | OptIfTIMDetMode | read-create | current |
| optIfODUkTNimTIMActEnabled OBJECT-TYPE Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. | 1.3.6.1.2.1.10.133.1.9.2.1.7 | TruthValue | read-create | current |
| optIfODUkTNimDEGThr OBJECT-TYPE Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to optIfODUkTNimDEGThr. | 1.3.6.1.2.1.10.133.1.9.2.1.8 | OptIfDEGThr | read-create | current |
| optIfODUkTNimDEGM OBJECT-TYPE Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if optIfODUkTNimDEGM consecutive bad PM Seconds are detected. | 1.3.6.1.2.1.10.133.1.9.2.1.9 | OptIfDEGM | read-create | current |
| optIfODUkTNimCurrentStatus OBJECT-TYPE Indicates the defect condition of the entity, if any. The value of this object is unspecified if optIfODUkTNimRowStatus has any value other than active(1). | 1.3.6.1.2.1.10.133.1.9.2.1.10 | Bits {oci(0), lck(1), tim(2), deg(3), bdi(4), ssf(5)} | read-only | current |
| optIfODUkTNimRowStatus OBJECT-TYPE This columnar object is used for creating and deleting a conceptual row of the optIfODUkTNim config table. It is used to model the addTCM and removeTCM operations of an ODUk_CTP or ODUk_TTP for non-intrusive Tandem connection monitoring as defined in ITU-T G.874.1. Setting RowStatus to createAndGo or createAndWait implies addTCM. Setting RowStatus to destroy implies removeTCM. Successful addition/removal of Nim TCM will result in updating the optIfODUkPositionSeqCurrentSize variable and the optIfODUkPositionSeqTable table of the associated ODUk entry in the optIfODUkConfigTable. | 1.3.6.1.2.1.10.133.1.9.2.1.11 | RowStatus | read-create | current |
| optIfConfs OBJECT-IDENTITY | 1.3.6.1.2.1.10.133.2 | |||
| optIfGroups OBJECT-IDENTITY | 1.3.6.1.2.1.10.133.2.1 | |||
| optIfCompl OBJECT-IDENTITY | 1.3.6.1.2.1.10.133.2.2 |
Conformance
| Name | OID | Status |
|---|---|---|
| optIfOTMnGroup OBJECT-GROUP A collection of OTMn structure information objects. | 1.3.6.1.2.1.10.133.2.1.1 | current |
| optIfPerfMonGroup OBJECT-GROUP A collection of performance monitoring interval objects. | 1.3.6.1.2.1.10.133.2.1.2 | current |
| optIfOTSnCommonGroup OBJECT-GROUP A collection of configuration objects applicable to all OTSn interfaces. | 1.3.6.1.2.1.10.133.2.1.3 | current |
| optIfOTSnSourceGroupFull OBJECT-GROUP A collection of configuration objects applicable to full-functionality/IaDI OTSn interfaces that support source functions. | 1.3.6.1.2.1.10.133.2.1.4 | current |
| optIfOTSnAPRStatusGroup OBJECT-GROUP A collection of objects applicable to OTSn interfaces that support Automatic Power Reduction functions. | 1.3.6.1.2.1.10.133.2.1.5 | current |
| optIfOTSnAPRControlGroup OBJECT-GROUP A collection of objects applicable to OTSn interfaces that provide Automatic Power Reduction control functions. | 1.3.6.1.2.1.10.133.2.1.6 | current |
| optIfOTSnSinkGroupBasic OBJECT-GROUP A collection of configuration objects applicable to all OTSn interfaces that support sink functions. | 1.3.6.1.2.1.10.133.2.1.7 | current |
| optIfOTSnSinkGroupFull OBJECT-GROUP A collection of configuration objects applicable to full-functionality/IaDI OTSn interfaces that support sink functions. | 1.3.6.1.2.1.10.133.2.1.8 | current |
| optIfOTSnSinkPreOtnPMGroup OBJECT-GROUP A collection of pre-OTN performance monitoring objects applicable to OTSn interfaces that support sink functions. | 1.3.6.1.2.1.10.133.2.1.9 | current |
| optIfOTSnSinkPreOtnPMThresholdGroup OBJECT-GROUP A collection of pre-OTN performance monitoring threshold objects applicable to OTSn interfaces that support sink functions. | 1.3.6.1.2.1.10.133.2.1.10 | current |
| optIfOTSnSourcePreOtnPMGroup OBJECT-GROUP A collection of pre-OTN performance monitoring objects applicable to OTSn interfaces that support source functions. | 1.3.6.1.2.1.10.133.2.1.11 | current |
| optIfOTSnSourcePreOtnPMThresholdGroup OBJECT-GROUP A collection of pre-OTN performance monitoring threshold objects applicable to OTSn interfaces that support source functions. | 1.3.6.1.2.1.10.133.2.1.12 | current |
| optIfOMSnCommonGroup OBJECT-GROUP A collection of configuration objects applicable to all OMSn interfaces. | 1.3.6.1.2.1.10.133.2.1.13 | current |
| optIfOMSnSinkGroupBasic OBJECT-GROUP A collection of configuration objects applicable to all OMSn interfaces that support sink functions. | 1.3.6.1.2.1.10.133.2.1.14 | current |
| optIfOMSnSinkPreOtnPMGroup OBJECT-GROUP A collection of pre-OTN performance monitoring objects applicable to OMSn interfaces that support sink functions. | 1.3.6.1.2.1.10.133.2.1.15 | current |
| optIfOMSnSinkPreOtnPMThresholdGroup OBJECT-GROUP A collection of pre-OTN performance monitoring threshold objects applicable to OMSn interfaces that support sink functions. | 1.3.6.1.2.1.10.133.2.1.16 | current |
| optIfOMSnSourcePreOtnPMGroup OBJECT-GROUP A collection of pre-OTN performance monitoring objects applicable to OMSn interfaces that support source functions. | 1.3.6.1.2.1.10.133.2.1.17 | current |
| optIfOMSnSourcePreOtnPMThresholdGroup OBJECT-GROUP A collection of pre-OTN performance monitoring threshold objects applicable to OMSn interfaces that that support source functions. | 1.3.6.1.2.1.10.133.2.1.18 | current |
| optIfOChGroupCommonGroup OBJECT-GROUP A collection of configuration objects applicable to all OChGroup interfaces. | 1.3.6.1.2.1.10.133.2.1.19 | current |
| optIfOChGroupSinkPreOtnPMGroup OBJECT-GROUP A collection of pre-OTN performance monitoring objects applicable to OChGroup interfaces that support sink functions. | 1.3.6.1.2.1.10.133.2.1.20 | current |
| optIfOChGroupSinkPreOtnPMThresholdGroup OBJECT-GROUP A collection of pre-OTN performance monitoring threshold objects applicable to OChGroup interfaces that support sink functions. | 1.3.6.1.2.1.10.133.2.1.21 | current |
| optIfOChGroupSourcePreOtnPMGroup OBJECT-GROUP A collection of pre-OTN performance monitoring objects applicable to OChGroup interfaces that support source functions. | 1.3.6.1.2.1.10.133.2.1.22 | current |
| optIfOChGroupSourcePreOtnPMThresholdGroup OBJECT-GROUP A collection of pre-OTN performance monitoring threshold objects applicable to OChGroup interfaces that that support source functions. | 1.3.6.1.2.1.10.133.2.1.23 | current |
| optIfOChCommonGroup OBJECT-GROUP A collection of configuration objects applicable to all OCh interfaces. | 1.3.6.1.2.1.10.133.2.1.24 | current |
| optIfOChSinkGroupBasic OBJECT-GROUP A collection of configuration objects applicable to all OCh interfaces that support sink functions. | 1.3.6.1.2.1.10.133.2.1.25 | current |
| optIfOChSinkPreOtnPMGroup OBJECT-GROUP A collection of pre-OTN performance monitoring objects applicable to OCh interfaces that support sink functions. | 1.3.6.1.2.1.10.133.2.1.26 | current |
| optIfOChSinkPreOtnPMThresholdGroup OBJECT-GROUP A collection of pre-OTN performance monitoring threshold objects applicable to OCh interfaces that support sink functions. | 1.3.6.1.2.1.10.133.2.1.27 | current |
| optIfOChSourcePreOtnPMGroup OBJECT-GROUP A collection of pre-OTN performance monitoring objects applicable to OCh interfaces that support source functions. | 1.3.6.1.2.1.10.133.2.1.28 | current |
| optIfOChSourcePreOtnPMThresholdGroup OBJECT-GROUP A collection of pre-OTN performance monitoring threshold objects applicable to OCh interfaces that support source functions. | 1.3.6.1.2.1.10.133.2.1.29 | current |
| optIfOTUkCommonGroup OBJECT-GROUP A collection of configuration objects applicable to all OTUk interfaces. | 1.3.6.1.2.1.10.133.2.1.30 | current |
| optIfOTUkSourceGroup OBJECT-GROUP A collection of configuration objects applicable to OTUk interfaces that support source functions. | 1.3.6.1.2.1.10.133.2.1.31 | current |
| optIfOTUkSinkGroup OBJECT-GROUP A collection of configuration objects applicable to OTUk interfaces that support sink functions. | 1.3.6.1.2.1.10.133.2.1.32 | current |
| optIfGCC0Group OBJECT-GROUP A collection of GCC0 configuration objects. | 1.3.6.1.2.1.10.133.2.1.33 | current |
| optIfODUkGroup OBJECT-GROUP A collection of configuration objects applicable to all ODUk interfaces. | 1.3.6.1.2.1.10.133.2.1.34 | current |
| optIfODUkTtpSourceGroup OBJECT-GROUP A collection of configuration objects applicable to all interfaces that support ODUk trail termination source functions. | 1.3.6.1.2.1.10.133.2.1.35 | current |
| optIfODUkTtpSinkGroup OBJECT-GROUP A collection of ODUk configuration objects applicable to all interfaces that support ODUk trail termination sink functions. | 1.3.6.1.2.1.10.133.2.1.36 | current |
| optIfODUkNimGroup OBJECT-GROUP A collection of ODUk Nim configuration objects. | 1.3.6.1.2.1.10.133.2.1.37 | current |
| optIfGCC12Group OBJECT-GROUP A collection of GCC12 configuration objects. | 1.3.6.1.2.1.10.133.2.1.38 | current |
| optIfODUkTCommonGroup OBJECT-GROUP A collection of configuration objects applicable to all ODUkT instances. | 1.3.6.1.2.1.10.133.2.1.39 | current |
| optIfODUkTSourceGroup OBJECT-GROUP A collection of configuration objects applicable to all ODUkT instances that provide source functions. | 1.3.6.1.2.1.10.133.2.1.40 | current |
| optIfODUkTSinkGroup OBJECT-GROUP A collection of configuration objects applicable to all ODUkT instances that provide sink functions. | 1.3.6.1.2.1.10.133.2.1.41 | current |
| optIfODUkTSinkGroupCtp OBJECT-GROUP A collection of configuration objects applicable to ODUkT instances not colocated with an ODUk TTP that provide sink functions. | 1.3.6.1.2.1.10.133.2.1.42 | current |
| optIfODUkTNimGroup OBJECT-GROUP A collection of ODUkT Nim configuration objects. | 1.3.6.1.2.1.10.133.2.1.43 | current |
| optIfOtnConfigCompl MODULE-COMPLIANCE Implementation requirements for the OTN configuration functions defined in this MIB module. | 1.3.6.1.2.1.10.133.2.2.1 | current |
| optIfPreOtnPMCompl MODULE-COMPLIANCE Implementation requirements for Pre-OTN performance monitoring functions defined in this MIB module. | 1.3.6.1.2.1.10.133.2.2.2 | current |