MIBs Depot

ONEACCESS-UPS-MIB

Registered at
1.3.6.1.4.1.13191.10.3.4.1225
Last updated
1994-02-23 00:00
Organization
IETF UPS MIB Working Group
Namespace
oneaccess
Source file
ONEACCESS-UPS-MIB
Digest
sha256:648c5965492246d2063cebefb44c2b845be505d2dacc7ed0cbe64abbbc04e64e

Description

The MIB module to describe Uninterruptible Power Supplies.

Contact

Pascal KESTELOOT Postal: ONE ACCESS 92140 Clamart, France FRANCE Tel: (+33) 01 41 87 70 54 Fax: (+33) 01 41 87 74 39 E-mail: pascal.kesteloot@oneaccess-net.com

Imports

FromSymbols
ONEACCESS-GLOBAL-REGoacExpIMManagement
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCAutonomousType, DisplayString, TEXTUAL-CONVENTION, TestAndIncr, TimeInterval, TimeStamp

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ONEACCESS-GLOBAL-REG
ONEACCESS-UPS-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
oacUpsMIBObjects
OBJECT-IDENTITY
1.3.6.1.4.1.13191.10.3.4.1225.1
oacUpsBattery
OBJECT-IDENTITY
1.3.6.1.4.1.13191.10.3.4.1225.1.1
oacUpsBatteryStatus
OBJECT-TYPE
The indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).
1.3.6.1.4.1.13191.10.3.4.1225.1.1.1INTEGER {unknown(1), batteryNormal(2), batteryLow(3), batteryDepleted(4)}read-onlycurrent
oacUpsAlarm
OBJECT-IDENTITY
1.3.6.1.4.1.13191.10.3.4.1225.1.2
oacUpsAlarmsPresent
OBJECT-TYPE
The present number of active alarm conditions.
1.3.6.1.4.1.13191.10.3.4.1225.1.2.1Gauge32read-onlycurrent
oacUpsAlarmDescr
OBJECT-TYPE
A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.
1.3.6.1.4.1.13191.10.3.4.1225.1.2.2AutonomousTyperead-onlycurrent
oacUpsAlarmTime
OBJECT-TYPE
The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of upsAlarmTime shall equal 0.
1.3.6.1.4.1.13191.10.3.4.1225.1.2.3TimeStampread-onlycurrent
oacUpsTraps
OBJECT-IDENTITY
1.3.6.1.4.1.13191.10.3.4.1225.2

Notifications

NameOIDStatus
oacUpsTrapAlarmEntryAdded
NOTIFICATION-TYPE
This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for upsAlarmOnBattery and upsAlarmTestInProgress.
1.3.6.1.4.1.13191.10.3.4.1225.2.0current
oacUpsTrapAlarmEntryRemoved
NOTIFICATION-TYPE
This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms except for upsAlarmTestInProgress.
1.3.6.1.4.1.13191.10.3.4.1225.2.1current