MIBs Depot

OLD-CISCO-ENV-MIB

Namespace
cisco
Source file
OLD-CISCO-ENV-MIB
Digest
sha256:4634064ea9a38a05c681cf6d37e3e2eeb856036e6052ab886a4ebc5ecf8531fb

Imports

FromSymbols
CISCO-SMIlocal
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

CISCO-SMI
OLD-CISCO-ENV-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
lenv
OBJECT-IDENTITY
1.3.6.1.4.1.9.2.1
envPresent
OBJECT-TYPE
Is there an environmental monitor card in this box?, 0 - No, 1-AGS card present, wrong firmware, 2-AGS CARD present, firmware ok, 3-7000 support
1.3.6.1.4.1.9.2.1.77INTEGERread-onlymandatory
envTestPt1Descr
OBJECT-TYPE
Description of the test point 1. Typically ambient air or the temperature of air entering the router
1.3.6.1.4.1.9.2.1.78DisplayStringread-onlymandatory
envTestPt1Measure
OBJECT-TYPE
Current value of test point 1. Typically a temperature in centigrade.
1.3.6.1.4.1.9.2.1.79INTEGERread-onlymandatory
envTestPt2Descr
OBJECT-TYPE
Description of the test point 2. Typically airflow or the temperature of air leaving the router
1.3.6.1.4.1.9.2.1.80DisplayStringread-onlymandatory
envTestPt2Measure
OBJECT-TYPE
Current value of test point 2. Typically a temperature in centigrade.
1.3.6.1.4.1.9.2.1.81INTEGERread-onlymandatory
envTestPt3Descr
OBJECT-TYPE
Description of the test point 3. Typically +5 volt
1.3.6.1.4.1.9.2.1.82DisplayStringread-onlymandatory
envTestPt3Measure
OBJECT-TYPE
Current value of test point 3. Typically the value in millivolts of the +5v supply
1.3.6.1.4.1.9.2.1.83INTEGERread-onlymandatory
envTestPt4Descr
OBJECT-TYPE
Description of the test point 4. Typically +12 volt
1.3.6.1.4.1.9.2.1.84DisplayStringread-onlymandatory
envTestPt4Measure
OBJECT-TYPE
Current value of test point 4. Typically the value in millivolts of the +12v supply
1.3.6.1.4.1.9.2.1.85INTEGERread-onlymandatory
envTestPt5Descr
OBJECT-TYPE
Description of the test point 5. Typically -12 volt
1.3.6.1.4.1.9.2.1.86DisplayStringread-onlymandatory
envTestPt5Measure
OBJECT-TYPE
Current value of test point 5. Typically the value in millivolts of the -12v supply
1.3.6.1.4.1.9.2.1.87INTEGERread-onlymandatory
envTestPt6Descr
OBJECT-TYPE
Description of the test point 6. Typically -5 volt
1.3.6.1.4.1.9.2.1.88DisplayStringread-onlymandatory
envTestPt6Measure
OBJECT-TYPE
Current value of test point 6. Typically the value in millivolts of the -5v supply
1.3.6.1.4.1.9.2.1.89INTEGERread-onlymandatory
envTestPt1MarginVal
OBJECT-TYPE
Value at which the router will shutdown. Typically the ambient air temperature that will shut the router down. (e.g. 43)
1.3.6.1.4.1.9.2.1.90INTEGERread-onlymandatory
envTestPt2MarginVal
OBJECT-TYPE
Value at which the router will shutdown. Typically the airflow air temperature that will shut the router down. (e.g. 58)
1.3.6.1.4.1.9.2.1.91INTEGERread-onlymandatory
envTestPt3MarginPercent
OBJECT-TYPE
+/- Percentage that will shut the router down, (e.g. 10%) typically +5 volt
1.3.6.1.4.1.9.2.1.92INTEGERread-onlymandatory
envTestPt4MarginPercent
OBJECT-TYPE
+/- Percentage that will shut the router down, (e.g. 15%) typically +12 volt
1.3.6.1.4.1.9.2.1.93INTEGERread-onlymandatory
envTestPt5MarginPercent
OBJECT-TYPE
+/- Percentage that will shut the router down, (e.g. 15%) typically -12 volt
1.3.6.1.4.1.9.2.1.94INTEGERread-onlymandatory
envTestPt6MarginPercent
OBJECT-TYPE
+/- Percentage that will shut the router down, (e.g. 10%) typically -5 volt
1.3.6.1.4.1.9.2.1.95INTEGERread-onlymandatory
envTestPt1last
OBJECT-TYPE
Value of TestPt1 when last shutdown occurred.
1.3.6.1.4.1.9.2.1.96INTEGERread-onlymandatory
envTestPt2last
OBJECT-TYPE
Value of TestPt2 when last shutdown occurred.
1.3.6.1.4.1.9.2.1.97INTEGERread-onlymandatory
envTestPt3last
OBJECT-TYPE
Value of TestPt3 when last shutdown occurred.
1.3.6.1.4.1.9.2.1.98INTEGERread-onlymandatory
envTestPt4last
OBJECT-TYPE
Value of TestPt4 when last shutdown occurred.
1.3.6.1.4.1.9.2.1.99INTEGERread-onlymandatory
envTestPt5last
OBJECT-TYPE
Value of TestPt5 when last shutdown occurred.
1.3.6.1.4.1.9.2.1.100INTEGERread-onlymandatory
envTestPt6last
OBJECT-TYPE
Value of TestPt6 when last shutdown occurred.
1.3.6.1.4.1.9.2.1.101INTEGERread-onlymandatory
envTestPt1warn
OBJECT-TYPE
Is this test point at a warning level?
1.3.6.1.4.1.9.2.1.102INTEGER {warning(1), noWarning(2)}read-onlymandatory
envTestPt2warn
OBJECT-TYPE
Is this test point at a warning level?
1.3.6.1.4.1.9.2.1.103INTEGER {warning(1), noWarning(2)}read-onlymandatory
envTestPt3warn
OBJECT-TYPE
Is this test point at a warning level?
1.3.6.1.4.1.9.2.1.104INTEGER {warning(1), noWarning(2)}read-onlymandatory
envTestPt4warn
OBJECT-TYPE
Is this test point at a warning level?
1.3.6.1.4.1.9.2.1.105INTEGER {warning(1), noWarning(2)}read-onlymandatory
envTestPt5warn
OBJECT-TYPE
Is this test point at a warning level?
1.3.6.1.4.1.9.2.1.106INTEGER {warning(1), noWarning(2)}read-onlymandatory
envTestPt6warn
OBJECT-TYPE
Is this test point at a warning level?
1.3.6.1.4.1.9.2.1.107INTEGER {warning(1), noWarning(2)}read-onlymandatory
envFirmVersion
OBJECT-TYPE
Description of Environmental Card firmware
1.3.6.1.4.1.9.2.1.108DisplayStringread-onlymandatory
envTechnicianID
OBJECT-TYPE
Technician ID
1.3.6.1.4.1.9.2.1.109DisplayStringread-onlymandatory
envType
OBJECT-TYPE
The type of environmental card
1.3.6.1.4.1.9.2.1.110DisplayStringread-onlymandatory
envBurnDate
OBJECT-TYPE
The calibration / burn in date
1.3.6.1.4.1.9.2.1.111DisplayStringread-onlymandatory
envSerialNumber
OBJECT-TYPE
Serial Number of environmental monitor card
1.3.6.1.4.1.9.2.1.112DisplayStringread-onlymandatory