Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| lenv OBJECT-IDENTITY | 1.3.6.1.4.1.9.2.1 | |||
| envPresent OBJECT-TYPE Is there an environmental monitor card in this box?, 0 - No, 1-AGS card present, wrong firmware, 2-AGS CARD present, firmware ok, 3-7000 support | 1.3.6.1.4.1.9.2.1.77 | INTEGER | read-only | mandatory |
| envTestPt1Descr OBJECT-TYPE Description of the test point 1. Typically ambient air or the temperature of air entering the router | 1.3.6.1.4.1.9.2.1.78 | DisplayString | read-only | mandatory |
| envTestPt1Measure OBJECT-TYPE Current value of test point 1. Typically a temperature in centigrade. | 1.3.6.1.4.1.9.2.1.79 | INTEGER | read-only | mandatory |
| envTestPt2Descr OBJECT-TYPE Description of the test point 2. Typically airflow or the temperature of air leaving the router | 1.3.6.1.4.1.9.2.1.80 | DisplayString | read-only | mandatory |
| envTestPt2Measure OBJECT-TYPE Current value of test point 2. Typically a temperature in centigrade. | 1.3.6.1.4.1.9.2.1.81 | INTEGER | read-only | mandatory |
| envTestPt3Descr OBJECT-TYPE Description of the test point 3. Typically +5 volt | 1.3.6.1.4.1.9.2.1.82 | DisplayString | read-only | mandatory |
| envTestPt3Measure OBJECT-TYPE Current value of test point 3. Typically the value in millivolts of the +5v supply | 1.3.6.1.4.1.9.2.1.83 | INTEGER | read-only | mandatory |
| envTestPt4Descr OBJECT-TYPE Description of the test point 4. Typically +12 volt | 1.3.6.1.4.1.9.2.1.84 | DisplayString | read-only | mandatory |
| envTestPt4Measure OBJECT-TYPE Current value of test point 4. Typically the value in millivolts of the +12v supply | 1.3.6.1.4.1.9.2.1.85 | INTEGER | read-only | mandatory |
| envTestPt5Descr OBJECT-TYPE Description of the test point 5. Typically -12 volt | 1.3.6.1.4.1.9.2.1.86 | DisplayString | read-only | mandatory |
| envTestPt5Measure OBJECT-TYPE Current value of test point 5. Typically the value in millivolts of the -12v supply | 1.3.6.1.4.1.9.2.1.87 | INTEGER | read-only | mandatory |
| envTestPt6Descr OBJECT-TYPE Description of the test point 6. Typically -5 volt | 1.3.6.1.4.1.9.2.1.88 | DisplayString | read-only | mandatory |
| envTestPt6Measure OBJECT-TYPE Current value of test point 6. Typically the value in millivolts of the -5v supply | 1.3.6.1.4.1.9.2.1.89 | INTEGER | read-only | mandatory |
| envTestPt1MarginVal OBJECT-TYPE Value at which the router will shutdown. Typically the ambient air temperature that will shut the router down. (e.g. 43) | 1.3.6.1.4.1.9.2.1.90 | INTEGER | read-only | mandatory |
| envTestPt2MarginVal OBJECT-TYPE Value at which the router will shutdown. Typically the airflow air temperature that will shut the router down. (e.g. 58) | 1.3.6.1.4.1.9.2.1.91 | INTEGER | read-only | mandatory |
| envTestPt3MarginPercent OBJECT-TYPE +/- Percentage that will shut the router down, (e.g. 10%) typically +5 volt | 1.3.6.1.4.1.9.2.1.92 | INTEGER | read-only | mandatory |
| envTestPt4MarginPercent OBJECT-TYPE +/- Percentage that will shut the router down, (e.g. 15%) typically +12 volt | 1.3.6.1.4.1.9.2.1.93 | INTEGER | read-only | mandatory |
| envTestPt5MarginPercent OBJECT-TYPE +/- Percentage that will shut the router down, (e.g. 15%) typically -12 volt | 1.3.6.1.4.1.9.2.1.94 | INTEGER | read-only | mandatory |
| envTestPt6MarginPercent OBJECT-TYPE +/- Percentage that will shut the router down, (e.g. 10%) typically -5 volt | 1.3.6.1.4.1.9.2.1.95 | INTEGER | read-only | mandatory |
| envTestPt1last OBJECT-TYPE Value of TestPt1 when last shutdown occurred. | 1.3.6.1.4.1.9.2.1.96 | INTEGER | read-only | mandatory |
| envTestPt2last OBJECT-TYPE Value of TestPt2 when last shutdown occurred. | 1.3.6.1.4.1.9.2.1.97 | INTEGER | read-only | mandatory |
| envTestPt3last OBJECT-TYPE Value of TestPt3 when last shutdown occurred. | 1.3.6.1.4.1.9.2.1.98 | INTEGER | read-only | mandatory |
| envTestPt4last OBJECT-TYPE Value of TestPt4 when last shutdown occurred. | 1.3.6.1.4.1.9.2.1.99 | INTEGER | read-only | mandatory |
| envTestPt5last OBJECT-TYPE Value of TestPt5 when last shutdown occurred. | 1.3.6.1.4.1.9.2.1.100 | INTEGER | read-only | mandatory |
| envTestPt6last OBJECT-TYPE Value of TestPt6 when last shutdown occurred. | 1.3.6.1.4.1.9.2.1.101 | INTEGER | read-only | mandatory |
| envTestPt1warn OBJECT-TYPE Is this test point at a warning level? | 1.3.6.1.4.1.9.2.1.102 | INTEGER {warning(1), noWarning(2)} | read-only | mandatory |
| envTestPt2warn OBJECT-TYPE Is this test point at a warning level? | 1.3.6.1.4.1.9.2.1.103 | INTEGER {warning(1), noWarning(2)} | read-only | mandatory |
| envTestPt3warn OBJECT-TYPE Is this test point at a warning level? | 1.3.6.1.4.1.9.2.1.104 | INTEGER {warning(1), noWarning(2)} | read-only | mandatory |
| envTestPt4warn OBJECT-TYPE Is this test point at a warning level? | 1.3.6.1.4.1.9.2.1.105 | INTEGER {warning(1), noWarning(2)} | read-only | mandatory |
| envTestPt5warn OBJECT-TYPE Is this test point at a warning level? | 1.3.6.1.4.1.9.2.1.106 | INTEGER {warning(1), noWarning(2)} | read-only | mandatory |
| envTestPt6warn OBJECT-TYPE Is this test point at a warning level? | 1.3.6.1.4.1.9.2.1.107 | INTEGER {warning(1), noWarning(2)} | read-only | mandatory |
| envFirmVersion OBJECT-TYPE Description of Environmental Card firmware | 1.3.6.1.4.1.9.2.1.108 | DisplayString | read-only | mandatory |
| envTechnicianID OBJECT-TYPE Technician ID | 1.3.6.1.4.1.9.2.1.109 | DisplayString | read-only | mandatory |
| envType OBJECT-TYPE The type of environmental card | 1.3.6.1.4.1.9.2.1.110 | DisplayString | read-only | mandatory |
| envBurnDate OBJECT-TYPE The calibration / burn in date | 1.3.6.1.4.1.9.2.1.111 | DisplayString | read-only | mandatory |
| envSerialNumber OBJECT-TYPE Serial Number of environmental monitor card | 1.3.6.1.4.1.9.2.1.112 | DisplayString | read-only | mandatory |