OCCAM-MLT-MIB
- Registered at
- 1.3.6.1.4.1.6066.2.1.1.3
- Last updated
- 2001-04-27 10:51
- Organization
- Occam Networks
- Revisions
- 2001-04-27 10:51, 2007-04-17 00:00, 2007-02-22 00:00, 2006-09-26 10:00, 2006-02-22 01:35
- Namespace
- calix
- Source file
OCCAM-MLT-MIB- Digest
sha256:ff57c5d90d051390fce9cb588d15414d566a363370bb624d35d29c7e252f3d15
Description
This mib module describes objects used to perform Metallic Line Testing on customer access lines and to provide results.
Contact
email support@occamnetworks.com
Imports
| From | Symbols |
|---|---|
| OCCAM-REG-MODULE | occamGenericMonitorModules |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
OCCAM-MLT-MIB OCCAM-REG-MODULE SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| MltTestHookState TEXTUAL-CONVENTION An mlt test hook state value. | current | |||
| MltTestIdentifier TEXTUAL-CONVENTION An mlt test selection value. | current | |||
| MltTestPassFail TEXTUAL-CONVENTION An mlt test pass/fail value. | current | |||
| MltTestRingerResult TEXTUAL-CONVENTION An mlt ringer test result value. | current | |||
| MltTestStatus TEXTUAL-CONVENTION An indication of test status: none = no test has been requested. mltbusy = another port is currently being tested. complete = the last requested test has completed. portInUse = the last requested port is in use, the test was not run. Rerunning the test as 'forced' will shut the port and run the test. inProgress = the last requested test is still running. mltError = the mlt program reported an error and aborted the test.Check the mltErrorText object. mltNotResponding = the mlt program didn't return a result. | current | |||
| MltTestType TEXTUAL-CONVENTION A selection value for requesting or forcing a test. A requested test will only run if the port is not in use. A forced test will immediately shut the port and run the test. | current | |||
| MltTestYesNo TEXTUAL-CONVENTION An mlt test pass/fail value. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| mltTestConfig OBJECT-IDENTITY | 1.3.6.1.4.1.6066.2.1.1.3.1 | |||
| mltTestIdentifier OBJECT-TYPE Selects the mlt test to be run. Setting this value starts a test. This is a required parameter. Approximate expected test durations are as follows: statusSuite 1 second mltSuite 1 minute activeModeVoltages 3 seconds highImpedanceModeVoltages 9 seconds dcResistance 18 seconds capacitance 18 seconds loopDetect 9 seconds loopLength 9 seconds. | 1.3.6.1.4.1.6066.2.1.1.3.1.1 | MltTestIdentifier | read-write | current |
| mltTestType OBJECT-TYPE Selects if a test is requested (only run if port is not in use) or forced. This is an optional parameter. If not specified, the request option is used. | 1.3.6.1.4.1.6066.2.1.1.3.1.2 | MltTestType | read-write | current |
| mltTestPort OBJECT-TYPE Selects voice channel on which test will be run. This is a required parameter. | 1.3.6.1.4.1.6066.2.1.1.3.1.3 | Integer32 (1..48) | read-write | current |
| mltDcResistanceRange OBJECT-TYPE Selects DC Resistance range value. This is an optional paramater. Default is 0 (auto mode). | 1.3.6.1.4.1.6066.2.1.1.3.1.4 | Integer32 (0..3) | read-write | current |
| mltLoopLengthMultiplier OBJECT-TYPE Selects loop length multiplier in nf. This is an optional parameter. If not specified an internal default value of 83nF/mile is used. | 1.3.6.1.4.1.6066.2.1.1.3.1.5 | Integer32 (10..200) | read-write | current |
| mltLoopDetectThreshold OBJECT-TYPE Selects the detection threshold in nF. This is an optional parameter. If not supplied, a loop detection threshold of 10nF is used. | 1.3.6.1.4.1.6066.2.1.1.3.1.6 | Integer32 (5..200) | read-write | current |
| mltTestStatus OBJECT-IDENTITY | 1.3.6.1.4.1.6066.2.1.1.3.2 | |||
| mltLastTestStatus OBJECT-TYPE Indicates the status of the last run mlt test. Given that the various mlt tests take several seconds to 1 1/2 minutes to run, it is suggested that status polls be spaced 10-20 seconds apart. Additionally, a monitoring application could wait for the testComplete notification. | 1.3.6.1.4.1.6066.2.1.1.3.2.1 | MltTestStatus | read-only | current |
| mltErrorText OBJECT-TYPE Indicates the textual error in the case of an aborted test. | 1.3.6.1.4.1.6066.2.1.1.3.2.2 | OCTET STRING | read-only | current |
| mltTestResults OBJECT-IDENTITY | 1.3.6.1.4.1.6066.2.1.1.3.3 | |||
| mltStatusResultsTable OBJECT-TYPE This table provides result of the status test suite. | 1.3.6.1.4.1.6066.2.1.1.3.3.1 | not-accessible | current | |
| mltStatusResultsEntry OBJECT-TYPE Entry holding information about results of status suite tests. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1 | not-accessible | current | |
| mltStatusAlarm OBJECT-TYPE Indicates GNK and/or OTEMP alarms active when status test was run. | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.1 | OCTET STRING | read-only | current |
| mltStatusHookState OBJECT-TYPE Indicates line hook state when status test was run. | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.2 | MltTestHookState | read-only | current |
| mltStatusTransversalCurrent OBJECT-TYPE Indicates transversal current when status test was run. | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.3 | Integer32 | read-only | current |
| mltStatusLongitudinalCurrent OBJECT-TYPE Indicates Longitudinal current when status test was run. | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.4 | Integer32 | read-only | current |
| mltStatusTipVoltage OBJECT-TYPE Indicates tip voltage when status test was run. | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.5 | Integer32 | read-only | current |
| mltStatusRingVoltage OBJECT-TYPE Indicates ring voltage when status test was run. | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.6 | Integer32 | read-only | current |
| mltStatusTipRingVoltage OBJECT-TYPE Indicates tip-ring voltage when status test was run. | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.7 | Integer32 | read-only | current |
| mltStatusVdd OBJECT-TYPE Indicates Vdd when status test was run. | 1.3.6.1.4.1.6066.2.1.1.3.3.1.1.8 | Integer32 | read-only | current |
| mltTestResultsTable OBJECT-TYPE This table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. Also, a resistance value of 9999 means that the result was greater than 1000 kOhms, but the exact value could not be measured. | 1.3.6.1.4.1.6066.2.1.1.3.3.2 | not-accessible | current | |
| mltTestResultsEntry OBJECT-TYPE Entry holding information about results of mlt suite tests. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1 | not-accessible | current | |
| mltTestAlarm OBJECT-TYPE GNK and OTEMP bits set by the DuSLIC will be reported as alarms. GNK is typically cause by ground fault or foreign voltage condition. OTEMP is set when the DuSLIC is experiencing thermal overload. This parameter is non-intrusive. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.1 | OCTET STRING | read-only | current |
| mltTestHookState OBJECT-TYPE Hook state reflects the DuSLIC hook bit (offhook/onhook). This parameter is non-intrusive. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.2 | MltTestHookState | read-only | current |
| mltTestVdd OBJECT-TYPE On HDPOTS, internal Voltage VDD will be reported and compared to statistically derived thresholds. This parameter is intrusive during offhook but will be available during onhook. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.3 | Integer32 | read-only | current |
| mltTestActiveModeVoltagesVdctr OBJECT-TYPE Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.4 | Integer32 | read-only | current |
| mltTestActiveModeVoltagesVdctg OBJECT-TYPE Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.5 | Integer32 | read-only | current |
| mltTestActiveModeVoltagesVdcrg OBJECT-TYPE Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.6 | Integer32 | read-only | current |
| mltTestActiveModeVoltagesVactr OBJECT-TYPE Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.7 | Integer32 | read-only | current |
| mltTestActiveModeVoltagesVactg OBJECT-TYPE Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.8 | Integer32 | read-only | current |
| mltTestActiveModeVoltagesVacrg OBJECT-TYPE Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.9 | Integer32 | read-only | current |
| mltTestHighImpedanceModeVoltagesVdctr OBJECT-TYPE High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.10 | Integer32 | read-only | current |
| mltTestHighImpedanceModeVoltagesVdctg OBJECT-TYPE High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.11 | Integer32 | read-only | current |
| mltTestHighImpedanceModeVoltagesVdcrg OBJECT-TYPE High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.12 | Integer32 | read-only | current |
| mltTestHighImpedanceModeVoltagesVactr OBJECT-TYPE High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.13 | Integer32 | read-only | current |
| mltTestHighImpedanceModeVoltagesVactg OBJECT-TYPE High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.14 | Integer32 | read-only | current |
| mltTestHighImpedanceModeVoltagesVacrg OBJECT-TYPE High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.15 | Integer32 | read-only | current |
| mltTestDcCurrentsItransversal OBJECT-TYPE Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.16 | Integer32 | read-only | current |
| mltTestDcCurrentsIlongitudinal OBJECT-TYPE Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.17 | Integer32 | read-only | current |
| mltTestDcCurrentsItip OBJECT-TYPE Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.18 | Integer32 | read-only | current |
| mltTestDcCurrentsIring OBJECT-TYPE Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.19 | Integer32 | read-only | current |
| mltTestCapacitanceCeqtr OBJECT-TYPE Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.20 | Integer32 | read-only | current |
| mltTestCapacitanceCeqtg OBJECT-TYPE Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.21 | Integer32 | read-only | current |
| mltTestCapacitanceCeqrg OBJECT-TYPE Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.22 | Integer32 | read-only | current |
| mltTestResistanceRtr OBJECT-TYPE DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state ` only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.23 | Integer32 | read-only | current |
| mltTestResistanceRtg OBJECT-TYPE DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.24 | Integer32 | read-only | current |
| mltTestResistanceRrg OBJECT-TYPE DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.25 | Integer32 | read-only | current |
| mltTestGr909HazardousPotentialTestResult OBJECT-TYPE This test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fail. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.26 | MltTestPassFail | read-only | current |
| mltTestGr909ForeignEmfTestResult OBJECT-TYPE This test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fail. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.27 | MltTestPassFail | read-only | current |
| mltTestGr909FuseTestTipFuse OBJECT-TYPE This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. This object is obsolete. Object name was changed. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.28 | MltTestPassFail | read-only | obsolete |
| mltTestGr909FuseTestRingFuse OBJECT-TYPE This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. This object is obsolete. Object name was changed. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.29 | MltTestPassFail | read-only | obsolete |
| mltTestGr909ResistiveFaultTestResult OBJECT-TYPE This test fails if the T-R, T-G or R-G dc resistance is less than 150k ohm. This test will not be performed if fuse test fails or alarm is present. This test will return pass/fail. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.30 | MltTestPassFail | read-only | current |
| mltTestGr909ReceiverOffhookTestResult OBJECT-TYPE This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.31 | MltTestPassFail | read-only | current |
| mltTestGr909ReceiverOffhookTestResistance1 OBJECT-TYPE This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.32 | Integer32 | read-only | current |
| mltTestGr909ReceiverOffhookTestResistance2 OBJECT-TYPE This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.33 | Integer32 | read-only | current |
| mltTestGr909ReceiverOffhookTestDifference OBJECT-TYPE This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.34 | Integer32 | read-only | current |
| mltTestGr909RingerTestResult OBJECT-TYPE This test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or alarm is present. This test will report passed/fail and the REN number. This parameter is intrusive and will be available in shutdown state shutdown only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.35 | MltTestRingerResult | read-only | current |
| mltTestGr909RingerTestRen OBJECT-TYPE This test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or alarm is present. This test will report passed/fail and the REN number. This parameter is intrusive and will be available in shutdown state shutdown only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.36 | Integer32 | read-only | current |
| mltTestErrors OBJECT-TYPE Indicates GNK and/or OTEMP alarms active when test was run. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.37 | OCTET STRING | read-only | current |
| mltTestFuseTestTipFuse OBJECT-TYPE This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.38 | MltTestPassFail | read-only | current |
| mltTestFuseTestRingFuse OBJECT-TYPE This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.2.1.39 | MltTestPassFail | read-only | current |
| mltActiveModeVoltagesResultsTable OBJECT-TYPE This table provides results of the mlt active mode voltages test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. | 1.3.6.1.4.1.6066.2.1.1.3.3.3 | not-accessible | current | |
| mltActiveModeVoltagesResultsEntry OBJECT-TYPE Entry holding information about results of mlt active mode voltages test. | 1.3.6.1.4.1.6066.2.1.1.3.3.3.1 | not-accessible | current | |
| mltActiveModeVoltagesVdctr OBJECT-TYPE Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.1 | Integer32 | read-only | current |
| mltActiveModeVoltagesVdctg OBJECT-TYPE Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.2 | Integer32 | read-only | current |
| mltActiveModeVoltagesVdcrg OBJECT-TYPE Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.3 | Integer32 | read-only | current |
| mltActiveModeVoltagesVactr OBJECT-TYPE Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.4 | Integer32 | read-only | current |
| mltActiveModeVoltagesVactg OBJECT-TYPE Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.5 | Integer32 | read-only | current |
| mltActiveModeVoltagesVacrg OBJECT-TYPE Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.6 | Integer32 | read-only | current |
| mltActiveModeVoltagesErrors OBJECT-TYPE Indicates GNK and/or OTEMP alarms active when test was run. | 1.3.6.1.4.1.6066.2.1.1.3.3.3.1.7 | OCTET STRING | read-only | current |
| mltHighImpedanceModeVoltagesResultsTable OBJECT-TYPE This table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. | 1.3.6.1.4.1.6066.2.1.1.3.3.4 | not-accessible | current | |
| mltHighImpedanceModeVoltagesResultsEntry OBJECT-TYPE Entry holding information about results of mlt high impedance mode voltages test. | 1.3.6.1.4.1.6066.2.1.1.3.3.4.1 | not-accessible | current | |
| mltHighImpedanceModeVoltagesVdctr OBJECT-TYPE High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.1 | Integer32 | read-only | current |
| mltHighImpedanceModeVoltagesVdctg OBJECT-TYPE High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.2 | Integer32 | read-only | current |
| mltHighImpedanceModeVoltagesVdcrg OBJECT-TYPE High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.3 | Integer32 | read-only | current |
| mltHighImpedanceModeVoltagesVactr OBJECT-TYPE High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.4 | Integer32 | read-only | current |
| mltHighImpedanceModeVoltagesVactg OBJECT-TYPE High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.5 | Integer32 | read-only | current |
| mltHighImpedanceModeVoltagesVacrg OBJECT-TYPE High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.6 | Integer32 | read-only | current |
| mltHighImpedanceModeVoltagesErrors OBJECT-TYPE Indicates GNK and/or OTEMP alarms active when test was run. | 1.3.6.1.4.1.6066.2.1.1.3.3.4.1.7 | OCTET STRING | read-only | current |
| mltDcResistanceResultsTable OBJECT-TYPE This table provides result of the DC resistance test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. Also, a resistance value of 9999 means that the result was greater than 1000 kOhms, but the exact value could not be measured. | 1.3.6.1.4.1.6066.2.1.1.3.3.5 | not-accessible | current | |
| mltDcResistanceResultsEntry OBJECT-TYPE Entry holding information about results of mlt DC resistance test. | 1.3.6.1.4.1.6066.2.1.1.3.3.5.1 | not-accessible | current | |
| mltDcResistanceRtr OBJECT-TYPE DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.5.1.1 | Integer32 | read-only | current |
| mltDcResistanceRtg OBJECT-TYPE DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.5.1.2 | Integer32 | read-only | current |
| mltDcResistanceRrg OBJECT-TYPE DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.5.1.3 | Integer32 | read-only | current |
| mltDcResistanceErrors OBJECT-TYPE Indicates GNK and/or OTEMP alarms active when test was run. | 1.3.6.1.4.1.6066.2.1.1.3.3.5.1.4 | OCTET STRING | read-only | current |
| mltCapacitanceResultsTable OBJECT-TYPE This table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. | 1.3.6.1.4.1.6066.2.1.1.3.3.6 | not-accessible | current | |
| mltCapacitanceResultsEntry OBJECT-TYPE Entry holding information about results of mlt capacitance test. | 1.3.6.1.4.1.6066.2.1.1.3.3.6.1 | not-accessible | current | |
| mltCapacitanceCeqtr OBJECT-TYPE Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.6.1.1 | Integer32 | read-only | current |
| mltCapacitanceCeqtg OBJECT-TYPE Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.6.1.2 | Integer32 | read-only | current |
| mltCapacitanceCeqrg OBJECT-TYPE Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.6.1.3 | Integer32 | read-only | current |
| mltCapacitanceErrors OBJECT-TYPE Indicates GNK and/or OTEMP alarms active when test was run. | 1.3.6.1.4.1.6066.2.1.1.3.3.6.1.4 | OCTET STRING | read-only | current |
| mltLoopDetectResultsTable OBJECT-TYPE This table provides result of the mlt loop detect test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. | 1.3.6.1.4.1.6066.2.1.1.3.3.7 | not-accessible | current | |
| mltLoopDetectResultsEntry OBJECT-TYPE Entry holding information about results of mlt loop detect test. | 1.3.6.1.4.1.6066.2.1.1.3.3.7.1 | not-accessible | current | |
| mltLoopDetectLoopCapacitance OBJECT-TYPE Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied,loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.7.1.1 | Integer32 | read-only | current |
| mltLoopDetectDetectionThreshold OBJECT-TYPE Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied, loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.7.1.2 | Integer32 | read-only | current |
| mltLoopDetectLoopDetected OBJECT-TYPE Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied, loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.7.1.3 | MltTestYesNo | read-only | current |
| mltLoopDetectErrors OBJECT-TYPE Indicates GNK and/or OTEMP alarms active when test was run. | 1.3.6.1.4.1.6066.2.1.1.3.3.7.1.4 | OCTET STRING | read-only | current |
| mltLoopLengthResultsTable OBJECT-TYPE This table provides result of the mlt loop length test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. | 1.3.6.1.4.1.6066.2.1.1.3.3.8 | not-accessible | current | |
| mltLoopLengthResultsEntry OBJECT-TYPE Entry holding information about results of mlt loop length test. | 1.3.6.1.4.1.6066.2.1.1.3.3.8.1 | not-accessible | current | |
| mltLoopLengthCapacitanceFactor OBJECT-TYPE Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.1 | Integer32 | read-only | current |
| mltLoopLengthLoopCapacitance OBJECT-TYPE Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.2 | Integer32 | read-only | current |
| mltLoopLengthLoopLength OBJECT-TYPE Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. | 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.3 | Integer32 | read-only | current |
| mltLoopLengthUncompensatedLoopCapacitance OBJECT-TYPE Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. This value has no DSL correction. | 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.4 | Integer32 | read-only | current |
| mltLoopLengthUncompensatedLoopLength OBJECT-TYPE Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. This value has no DSL correction. | 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.5 | Integer32 | read-only | current |
| mltLoopLengthErrors OBJECT-TYPE Indicates GNK and/or OTEMP alarms active when test was run. | 1.3.6.1.4.1.6066.2.1.1.3.3.8.1.6 | OCTET STRING | read-only | current |
| mltTestNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.6066.2.1.1.3.4 |
Notifications
| Name | OID | Status |
|---|---|---|
| mltTestCompletedNotification NOTIFICATION-TYPE This notification is sent to the requesting host when the requested mlt test has completed. | 1.3.6.1.4.1.6066.2.1.1.3.4.1 | current |