MIBs Depot

OCCAM-MLT-MIB

Registered at
1.3.6.1.4.1.6066.2.1.1.3
Last updated
2001-04-27 10:51
Organization
Occam Networks
Revisions
2001-04-27 10:51, 2007-04-17 00:00, 2007-02-22 00:00, 2006-09-26 10:00, 2006-02-22 01:35
Namespace
calix
Source file
OCCAM-MLT-MIB
Digest
sha256:ff57c5d90d051390fce9cb588d15414d566a363370bb624d35d29c7e252f3d15

Description

This mib module describes objects used to perform Metallic Line Testing on customer access lines and to provide results.

Contact

email support@occamnetworks.com

Imports

FromSymbols
OCCAM-REG-MODULEoccamGenericMonitorModules
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

OCCAM-MLT-MIB
OCCAM-REG-MODULE
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
MltTestHookState
TEXTUAL-CONVENTION
An mlt test hook state value.
current
MltTestIdentifier
TEXTUAL-CONVENTION
An mlt test selection value.
current
MltTestPassFail
TEXTUAL-CONVENTION
An mlt test pass/fail value.
current
MltTestRingerResult
TEXTUAL-CONVENTION
An mlt ringer test result value.
current
MltTestStatus
TEXTUAL-CONVENTION
An indication of test status: none = no test has been requested. mltbusy = another port is currently being tested. complete = the last requested test has completed. portInUse = the last requested port is in use, the test was not run. Rerunning the test as 'forced' will shut the port and run the test. inProgress = the last requested test is still running. mltError = the mlt program reported an error and aborted the test.Check the mltErrorText object. mltNotResponding = the mlt program didn't return a result.
current
MltTestType
TEXTUAL-CONVENTION
A selection value for requesting or forcing a test. A requested test will only run if the port is not in use. A forced test will immediately shut the port and run the test.
current
MltTestYesNo
TEXTUAL-CONVENTION
An mlt test pass/fail value.
current

Objects

NameOIDSyntaxAccessStatus
mltTestConfig
OBJECT-IDENTITY
1.3.6.1.4.1.6066.2.1.1.3.1
mltTestIdentifier
OBJECT-TYPE
Selects the mlt test to be run. Setting this value starts a test. This is a required parameter. Approximate expected test durations are as follows: statusSuite 1 second mltSuite 1 minute activeModeVoltages 3 seconds highImpedanceModeVoltages 9 seconds dcResistance 18 seconds capacitance 18 seconds loopDetect 9 seconds loopLength 9 seconds.
1.3.6.1.4.1.6066.2.1.1.3.1.1MltTestIdentifierread-writecurrent
mltTestType
OBJECT-TYPE
Selects if a test is requested (only run if port is not in use) or forced. This is an optional parameter. If not specified, the request option is used.
1.3.6.1.4.1.6066.2.1.1.3.1.2MltTestTyperead-writecurrent
mltTestPort
OBJECT-TYPE
Selects voice channel on which test will be run. This is a required parameter.
1.3.6.1.4.1.6066.2.1.1.3.1.3Integer32 (1..48)read-writecurrent
mltDcResistanceRange
OBJECT-TYPE
Selects DC Resistance range value. This is an optional paramater. Default is 0 (auto mode).
1.3.6.1.4.1.6066.2.1.1.3.1.4Integer32 (0..3)read-writecurrent
mltLoopLengthMultiplier
OBJECT-TYPE
Selects loop length multiplier in nf. This is an optional parameter. If not specified an internal default value of 83nF/mile is used.
1.3.6.1.4.1.6066.2.1.1.3.1.5Integer32 (10..200)read-writecurrent
mltLoopDetectThreshold
OBJECT-TYPE
Selects the detection threshold in nF. This is an optional parameter. If not supplied, a loop detection threshold of 10nF is used.
1.3.6.1.4.1.6066.2.1.1.3.1.6Integer32 (5..200)read-writecurrent
mltTestStatus
OBJECT-IDENTITY
1.3.6.1.4.1.6066.2.1.1.3.2
mltLastTestStatus
OBJECT-TYPE
Indicates the status of the last run mlt test. Given that the various mlt tests take several seconds to 1 1/2 minutes to run, it is suggested that status polls be spaced 10-20 seconds apart. Additionally, a monitoring application could wait for the testComplete notification.
1.3.6.1.4.1.6066.2.1.1.3.2.1MltTestStatusread-onlycurrent
mltErrorText
OBJECT-TYPE
Indicates the textual error in the case of an aborted test.
1.3.6.1.4.1.6066.2.1.1.3.2.2OCTET STRINGread-onlycurrent
mltTestResults
OBJECT-IDENTITY
1.3.6.1.4.1.6066.2.1.1.3.3
mltStatusResultsTable
OBJECT-TYPE
This table provides result of the status test suite.
1.3.6.1.4.1.6066.2.1.1.3.3.1not-accessiblecurrent
mltStatusResultsEntry
OBJECT-TYPE
Entry holding information about results of status suite tests. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured.
1.3.6.1.4.1.6066.2.1.1.3.3.1.1not-accessiblecurrent
mltStatusAlarm
OBJECT-TYPE
Indicates GNK and/or OTEMP alarms active when status test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.1.1.1OCTET STRINGread-onlycurrent
mltStatusHookState
OBJECT-TYPE
Indicates line hook state when status test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.1.1.2MltTestHookStateread-onlycurrent
mltStatusTransversalCurrent
OBJECT-TYPE
Indicates transversal current when status test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.1.1.3Integer32read-onlycurrent
mltStatusLongitudinalCurrent
OBJECT-TYPE
Indicates Longitudinal current when status test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.1.1.4Integer32read-onlycurrent
mltStatusTipVoltage
OBJECT-TYPE
Indicates tip voltage when status test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.1.1.5Integer32read-onlycurrent
mltStatusRingVoltage
OBJECT-TYPE
Indicates ring voltage when status test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.1.1.6Integer32read-onlycurrent
mltStatusTipRingVoltage
OBJECT-TYPE
Indicates tip-ring voltage when status test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.1.1.7Integer32read-onlycurrent
mltStatusVdd
OBJECT-TYPE
Indicates Vdd when status test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.1.1.8Integer32read-onlycurrent
mltTestResultsTable
OBJECT-TYPE
This table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. Also, a resistance value of 9999 means that the result was greater than 1000 kOhms, but the exact value could not be measured.
1.3.6.1.4.1.6066.2.1.1.3.3.2not-accessiblecurrent
mltTestResultsEntry
OBJECT-TYPE
Entry holding information about results of mlt suite tests.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1not-accessiblecurrent
mltTestAlarm
OBJECT-TYPE
GNK and OTEMP bits set by the DuSLIC will be reported as alarms. GNK is typically cause by ground fault or foreign voltage condition. OTEMP is set when the DuSLIC is experiencing thermal overload. This parameter is non-intrusive.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.1OCTET STRINGread-onlycurrent
mltTestHookState
OBJECT-TYPE
Hook state reflects the DuSLIC hook bit (offhook/onhook). This parameter is non-intrusive.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.2MltTestHookStateread-onlycurrent
mltTestVdd
OBJECT-TYPE
On HDPOTS, internal Voltage VDD will be reported and compared to statistically derived thresholds. This parameter is intrusive during offhook but will be available during onhook.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.3Integer32read-onlycurrent
mltTestActiveModeVoltagesVdctr
OBJECT-TYPE
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.4Integer32read-onlycurrent
mltTestActiveModeVoltagesVdctg
OBJECT-TYPE
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.5Integer32read-onlycurrent
mltTestActiveModeVoltagesVdcrg
OBJECT-TYPE
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.6Integer32read-onlycurrent
mltTestActiveModeVoltagesVactr
OBJECT-TYPE
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.7Integer32read-onlycurrent
mltTestActiveModeVoltagesVactg
OBJECT-TYPE
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.8Integer32read-onlycurrent
mltTestActiveModeVoltagesVacrg
OBJECT-TYPE
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.9Integer32read-onlycurrent
mltTestHighImpedanceModeVoltagesVdctr
OBJECT-TYPE
High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.10Integer32read-onlycurrent
mltTestHighImpedanceModeVoltagesVdctg
OBJECT-TYPE
High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.11Integer32read-onlycurrent
mltTestHighImpedanceModeVoltagesVdcrg
OBJECT-TYPE
High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.12Integer32read-onlycurrent
mltTestHighImpedanceModeVoltagesVactr
OBJECT-TYPE
High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.13Integer32read-onlycurrent
mltTestHighImpedanceModeVoltagesVactg
OBJECT-TYPE
High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.14Integer32read-onlycurrent
mltTestHighImpedanceModeVoltagesVacrg
OBJECT-TYPE
High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.15Integer32read-onlycurrent
mltTestDcCurrentsItransversal
OBJECT-TYPE
Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.16Integer32read-onlycurrent
mltTestDcCurrentsIlongitudinal
OBJECT-TYPE
Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.17Integer32read-onlycurrent
mltTestDcCurrentsItip
OBJECT-TYPE
Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.18Integer32read-onlycurrent
mltTestDcCurrentsIring
OBJECT-TYPE
Four DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.19Integer32read-onlycurrent
mltTestCapacitanceCeqtr
OBJECT-TYPE
Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.20Integer32read-onlycurrent
mltTestCapacitanceCeqtg
OBJECT-TYPE
Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.21Integer32read-onlycurrent
mltTestCapacitanceCeqrg
OBJECT-TYPE
Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.22Integer32read-onlycurrent
mltTestResistanceRtr
OBJECT-TYPE
DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state ` only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.23Integer32read-onlycurrent
mltTestResistanceRtg
OBJECT-TYPE
DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.24Integer32read-onlycurrent
mltTestResistanceRrg
OBJECT-TYPE
DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.25Integer32read-onlycurrent
mltTestGr909HazardousPotentialTestResult
OBJECT-TYPE
This test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fail. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.26MltTestPassFailread-onlycurrent
mltTestGr909ForeignEmfTestResult
OBJECT-TYPE
This test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fail. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.27MltTestPassFailread-onlycurrent
mltTestGr909FuseTestTipFuse
OBJECT-TYPE
This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. This object is obsolete. Object name was changed.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.28MltTestPassFailread-onlyobsolete
mltTestGr909FuseTestRingFuse
OBJECT-TYPE
This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. This object is obsolete. Object name was changed.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.29MltTestPassFailread-onlyobsolete
mltTestGr909ResistiveFaultTestResult
OBJECT-TYPE
This test fails if the T-R, T-G or R-G dc resistance is less than 150k ohm. This test will not be performed if fuse test fails or alarm is present. This test will return pass/fail. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.30MltTestPassFailread-onlycurrent
mltTestGr909ReceiverOffhookTestResult
OBJECT-TYPE
This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.31MltTestPassFailread-onlycurrent
mltTestGr909ReceiverOffhookTestResistance1
OBJECT-TYPE
This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.32Integer32read-onlycurrent
mltTestGr909ReceiverOffhookTestResistance2
OBJECT-TYPE
This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.33Integer32read-onlycurrent
mltTestGr909ReceiverOffhookTestDifference
OBJECT-TYPE
This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.34Integer32read-onlycurrent
mltTestGr909RingerTestResult
OBJECT-TYPE
This test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or alarm is present. This test will report passed/fail and the REN number. This parameter is intrusive and will be available in shutdown state shutdown only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.35MltTestRingerResultread-onlycurrent
mltTestGr909RingerTestRen
OBJECT-TYPE
This test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or alarm is present. This test will report passed/fail and the REN number. This parameter is intrusive and will be available in shutdown state shutdown only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.36Integer32read-onlycurrent
mltTestErrors
OBJECT-TYPE
Indicates GNK and/or OTEMP alarms active when test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.37OCTET STRINGread-onlycurrent
mltTestFuseTestTipFuse
OBJECT-TYPE
This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.38MltTestPassFailread-onlycurrent
mltTestFuseTestRingFuse
OBJECT-TYPE
This test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.2.1.39MltTestPassFailread-onlycurrent
mltActiveModeVoltagesResultsTable
OBJECT-TYPE
This table provides results of the mlt active mode voltages test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured.
1.3.6.1.4.1.6066.2.1.1.3.3.3not-accessiblecurrent
mltActiveModeVoltagesResultsEntry
OBJECT-TYPE
Entry holding information about results of mlt active mode voltages test.
1.3.6.1.4.1.6066.2.1.1.3.3.3.1not-accessiblecurrent
mltActiveModeVoltagesVdctr
OBJECT-TYPE
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.3.1.1Integer32read-onlycurrent
mltActiveModeVoltagesVdctg
OBJECT-TYPE
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.3.1.2Integer32read-onlycurrent
mltActiveModeVoltagesVdcrg
OBJECT-TYPE
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.3.1.3Integer32read-onlycurrent
mltActiveModeVoltagesVactr
OBJECT-TYPE
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.3.1.4Integer32read-onlycurrent
mltActiveModeVoltagesVactg
OBJECT-TYPE
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.3.1.5Integer32read-onlycurrent
mltActiveModeVoltagesVacrg
OBJECT-TYPE
Active Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.3.1.6Integer32read-onlycurrent
mltActiveModeVoltagesErrors
OBJECT-TYPE
Indicates GNK and/or OTEMP alarms active when test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.3.1.7OCTET STRINGread-onlycurrent
mltHighImpedanceModeVoltagesResultsTable
OBJECT-TYPE
This table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured.
1.3.6.1.4.1.6066.2.1.1.3.3.4not-accessiblecurrent
mltHighImpedanceModeVoltagesResultsEntry
OBJECT-TYPE
Entry holding information about results of mlt high impedance mode voltages test.
1.3.6.1.4.1.6066.2.1.1.3.3.4.1not-accessiblecurrent
mltHighImpedanceModeVoltagesVdctr
OBJECT-TYPE
High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.4.1.1Integer32read-onlycurrent
mltHighImpedanceModeVoltagesVdctg
OBJECT-TYPE
High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.4.1.2Integer32read-onlycurrent
mltHighImpedanceModeVoltagesVdcrg
OBJECT-TYPE
High Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.4.1.3Integer32read-onlycurrent
mltHighImpedanceModeVoltagesVactr
OBJECT-TYPE
High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.4.1.4Integer32read-onlycurrent
mltHighImpedanceModeVoltagesVactg
OBJECT-TYPE
High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.4.1.5Integer32read-onlycurrent
mltHighImpedanceModeVoltagesVacrg
OBJECT-TYPE
High Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.4.1.6Integer32read-onlycurrent
mltHighImpedanceModeVoltagesErrors
OBJECT-TYPE
Indicates GNK and/or OTEMP alarms active when test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.4.1.7OCTET STRINGread-onlycurrent
mltDcResistanceResultsTable
OBJECT-TYPE
This table provides result of the DC resistance test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. Also, a resistance value of 9999 means that the result was greater than 1000 kOhms, but the exact value could not be measured.
1.3.6.1.4.1.6066.2.1.1.3.3.5not-accessiblecurrent
mltDcResistanceResultsEntry
OBJECT-TYPE
Entry holding information about results of mlt DC resistance test.
1.3.6.1.4.1.6066.2.1.1.3.3.5.1not-accessiblecurrent
mltDcResistanceRtr
OBJECT-TYPE
DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.5.1.1Integer32read-onlycurrent
mltDcResistanceRtg
OBJECT-TYPE
DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.5.1.2Integer32read-onlycurrent
mltDcResistanceRrg
OBJECT-TYPE
DC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.5.1.3Integer32read-onlycurrent
mltDcResistanceErrors
OBJECT-TYPE
Indicates GNK and/or OTEMP alarms active when test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.5.1.4OCTET STRINGread-onlycurrent
mltCapacitanceResultsTable
OBJECT-TYPE
This table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured.
1.3.6.1.4.1.6066.2.1.1.3.3.6not-accessiblecurrent
mltCapacitanceResultsEntry
OBJECT-TYPE
Entry holding information about results of mlt capacitance test.
1.3.6.1.4.1.6066.2.1.1.3.3.6.1not-accessiblecurrent
mltCapacitanceCeqtr
OBJECT-TYPE
Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.6.1.1Integer32read-onlycurrent
mltCapacitanceCeqtg
OBJECT-TYPE
Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.6.1.2Integer32read-onlycurrent
mltCapacitanceCeqrg
OBJECT-TYPE
Capacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.6.1.3Integer32read-onlycurrent
mltCapacitanceErrors
OBJECT-TYPE
Indicates GNK and/or OTEMP alarms active when test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.6.1.4OCTET STRINGread-onlycurrent
mltLoopDetectResultsTable
OBJECT-TYPE
This table provides result of the mlt loop detect test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured.
1.3.6.1.4.1.6066.2.1.1.3.3.7not-accessiblecurrent
mltLoopDetectResultsEntry
OBJECT-TYPE
Entry holding information about results of mlt loop detect test.
1.3.6.1.4.1.6066.2.1.1.3.3.7.1not-accessiblecurrent
mltLoopDetectLoopCapacitance
OBJECT-TYPE
Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied,loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.7.1.1Integer32read-onlycurrent
mltLoopDetectDetectionThreshold
OBJECT-TYPE
Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied, loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.7.1.2Integer32read-onlycurrent
mltLoopDetectLoopDetected
OBJECT-TYPE
Loop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied, loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.7.1.3MltTestYesNoread-onlycurrent
mltLoopDetectErrors
OBJECT-TYPE
Indicates GNK and/or OTEMP alarms active when test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.7.1.4OCTET STRINGread-onlycurrent
mltLoopLengthResultsTable
OBJECT-TYPE
This table provides result of the mlt loop length test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured.
1.3.6.1.4.1.6066.2.1.1.3.3.8not-accessiblecurrent
mltLoopLengthResultsEntry
OBJECT-TYPE
Entry holding information about results of mlt loop length test.
1.3.6.1.4.1.6066.2.1.1.3.3.8.1not-accessiblecurrent
mltLoopLengthCapacitanceFactor
OBJECT-TYPE
Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.8.1.1Integer32read-onlycurrent
mltLoopLengthLoopCapacitance
OBJECT-TYPE
Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.8.1.2Integer32read-onlycurrent
mltLoopLengthLoopLength
OBJECT-TYPE
Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.
1.3.6.1.4.1.6066.2.1.1.3.3.8.1.3Integer32read-onlycurrent
mltLoopLengthUncompensatedLoopCapacitance
OBJECT-TYPE
Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. This value has no DSL correction.
1.3.6.1.4.1.6066.2.1.1.3.3.8.1.4Integer32read-onlycurrent
mltLoopLengthUncompensatedLoopLength
OBJECT-TYPE
Loop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. This value has no DSL correction.
1.3.6.1.4.1.6066.2.1.1.3.3.8.1.5Integer32read-onlycurrent
mltLoopLengthErrors
OBJECT-TYPE
Indicates GNK and/or OTEMP alarms active when test was run.
1.3.6.1.4.1.6066.2.1.1.3.3.8.1.6OCTET STRINGread-onlycurrent
mltTestNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.6066.2.1.1.3.4

Notifications

NameOIDStatus
mltTestCompletedNotification
NOTIFICATION-TYPE
This notification is sent to the requesting host when the requested mlt test has completed.
1.3.6.1.4.1.6066.2.1.1.3.4.1current