NSCRTV-ROOT
- Registered at
- 1.3.6.1.4.1.17409
- Namespace
- nscrtv
- Source file
NSCRTV-ROOT- Digest
sha256:32ee7ce0e36ef3531aeccc9dd7cf1ca0606419ad5667997fa0348a64ae331f37
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
NSCRTV-ROOT SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| nscrtvRoot OBJECT-IDENTITY | 1.3.6.1.4.1.17409 | |||
| nscrtvHFCemsTree OBJECT-IDENTITY | 1.3.6.1.4.1.17409.1 | |||
| propertyIdent OBJECT-IDENTITY | 1.3.6.1.4.1.17409.1.1 | |||
| analogPropertyTable OBJECT-TYPE Attribute Table simulation parameters | 1.3.6.1.4.1.17409.1.1.1 | not-accessible | mandatory | |
| analogPropertyEntry OBJECT-TYPE Attribute Table simulation parameters head. OID purpose as a table index,Its coding method is'length��OID'��OID former two members'1.3'According to '1'and'3'respectively coding,Instead of ordinary OID encoding (0x2B). | 1.3.6.1.4.1.17409.1.1.1.1 | not-accessible | mandatory | |
| analogParameterOID OBJECT-TYPE index | 1.3.6.1.4.1.17409.1.1.1.1.1 | OBJECT IDENTIFIER | read-only | mandatory |
| alarmEnable OBJECT-TYPE Alarm enable control byte, the corresponding position for the'1 'that allow alarm,'0' a ban warning Bit 0: Alarm enable low Bit 1: Alarm enable low Bit 2: Alarm enable high Bit 3: Alarm enable high Bit 4 ~ 7 reservations should be 0 This object should be stored in nonvolatile memory. | 1.3.6.1.4.1.17409.1.1.1.1.2 | OCTET STRING (SIZE(1)) | read-write | mandatory |
| analogAlarmState OBJECT-TYPE The parameters of the current state of alarm. | 1.3.6.1.4.1.17409.1.1.1.1.3 | INTEGER {aasNominal(1), aasHIHI(2), aasHI(3), aasLO(4), aasLOLO(5)} | read-only | mandatory |
| analogAlarmHIHI OBJECT-TYPE Alarm HIHI high threshold value. This object should be stored in non-volatile memory. | 1.3.6.1.4.1.17409.1.1.1.1.4 | INTEGER | read-write | mandatory |
| analogAlarmHI OBJECT-TYPE HI high alarm threshold value. This object should be stored in non-volatile memory. | 1.3.6.1.4.1.17409.1.1.1.1.5 | INTEGER | read-write | mandatory |
| analogAlarmLO OBJECT-TYPE LO low alarm threshold value. This object should be stored in non-volatile memory. | 1.3.6.1.4.1.17409.1.1.1.1.6 | INTEGER | read-write | mandatory |
| analogAlarmLOLO OBJECT-TYPE Alarm LOLO very low threshold value. This object should be stored in non-volatile memory. | 1.3.6.1.4.1.17409.1.1.1.1.7 | INTEGER | read-write | mandatory |
| analogAlarmDeadband OBJECT-TYPE Dead-alarm threshold value. After the warning, parameter values should be restored to the alarm threshold and alarm threshold and the difference between the absolute value greater than the value of dead zone, the alarm can be removed. This object should be stored in nonvolatile memory. | 1.3.6.1.4.1.17409.1.1.1.1.8 | INTEGER | read-write | mandatory |
| discretePropertyTable OBJECT-TYPE Discrete Attribute Table. | 1.3.6.1.4.1.17409.1.1.2 | not-accessible | mandatory | |
| discretePropertyEntry OBJECT-TYPE Attribute Table discrete head. OID coding methods with simulation attribute table | 1.3.6.1.4.1.17409.1.1.2.1 | not-accessible | mandatory | |
| discreteParameterOID OBJECT-TYPE Attribute Table discrete index 1: Parameters OID. | 1.3.6.1.4.1.17409.1.1.2.1.1 | OBJECT IDENTIFIER | read-only | mandatory |
| discreteAlarmValue OBJECT-TYPE Attribute Table discrete index 2: parameter values. When the equipment value of this parameter values, and so will be dealt with a warning. | 1.3.6.1.4.1.17409.1.1.2.1.2 | INTEGER | read-only | mandatory |
| discreteAlarmEnable OBJECT-TYPE When the alarm so that it can open the (2 or 3), this parameter allows for alarm processing. If the alarm so that it can shut down (1), alarm processing will be carried out. This object default values for the disable (1). This object should be stored in non-volatile memory. | 1.3.6.1.4.1.17409.1.1.2.1.3 | INTEGER {disable(1), enableMajor(2), enableMinor(3)} | read-write | mandatory |
| discreteAlarmState OBJECT-TYPE The parameters of the current state of alarm. | 1.3.6.1.4.1.17409.1.1.2.1.4 | INTEGER {dasNominal(1), dasDiscreteMajor(6), dasDiscreteMinor(7)} | read-only | mandatory |
| currentAlarmTable OBJECT-TYPE The current warning Table. | 1.3.6.1.4.1.17409.1.1.3 | not-accessible | mandatory | |
| currentAlarmEntry OBJECT-TYPE The current warning Table Head. OID coding methods with simulation attribute table. | 1.3.6.1.4.1.17409.1.1.3.1 | not-accessible | mandatory | |
| currentAlarmOID OBJECT-TYPE NE, currently in a state of alarm parameters OID Index, and attribute the alarm in the table corresponding parameters OID. | 1.3.6.1.4.1.17409.1.1.3.1.1 | OBJECT IDENTIFIER | read-only | mandatory |
| currentAlarmState OBJECT-TYPE Warning parameters of the current state of alarm. | 1.3.6.1.4.1.17409.1.1.3.1.2 | INTEGER {caasHIHI(2), caasHI(3), caasLO(4), caasLOLO(5), caasDiscreteMajor(6), caasDiscreteMinor(7)} | read-only | mandatory |
| currentAlarmValue OBJECT-TYPE Alarm parameter's value. | 1.3.6.1.4.1.17409.1.1.3.1.3 | INTEGER | read-only | mandatory |
| alarmsIdent OBJECT-IDENTITY | 1.3.6.1.4.1.17409.1.2 | |||
| alarmLogNumberOfEntries OBJECT-TYPE Alarm record number of records in the table. | 1.3.6.1.4.1.17409.1.2.1 | INTEGER | read-only | mandatory |
| alarmLogLastIndex OBJECT-TYPE Recently a warning the index of the records. | 1.3.6.1.4.1.17409.1.2.2 | INTEGER | read-only | mandatory |
| alarmLogTable OBJECT-TYPE Alarm record form, at least support 16 record. Each table in the registration of a new record, the management agent (transponder) managers should send traps news. | 1.3.6.1.4.1.17409.1.2.3 | not-accessible | mandatory | |
| alarmLogEntry OBJECT-TYPE Alarm Sheet Head. | 1.3.6.1.4.1.17409.1.2.3.1 | not-accessible | mandatory | |
| alarmLogIndex OBJECT-TYPE The only logo Alarm Index recorded a record in the table, the index value increased from 1 start of each new record, plus 1 until 32,767, a record index of the re-starts at 1. Acting under the management of storage capacity can be the first choice to delete those records, the specific details in this not to achieve provisions. | 1.3.6.1.4.1.17409.1.2.3.1.1 | INTEGER (1..32767) | read-only | mandatory |
| alarmLogInformation OBJECT-TYPE Alarm record information, multi-byte strings, defined as follows: Byte 1 ~ 4: Alarm in time (POSIX format, the previous maximum byte) Byte 5: Alarm types (enumeration, definitions see behind) Byte 6: Alarm value after commonNeStatus Byte 7 ~ m: Alarm parameters object identifier (Basic Encoding Rules (ASN.1)) Byte n ~ z: Alarm parameter values (Basic Encoding Rules (ASN.1)) Alarm enumerated types: 1 NOMINAL 2 HIHI 3 HI 4 LO 5 LOLO 6 Discrete Major 7 Discrete Minor | 1.3.6.1.4.1.17409.1.2.3.1.2 | OCTET STRING (SIZE(17..255)) | read-only | mandatory |
| alarmText OBJECT-TYPE This trap targets for the needs of information contained in a text field transponder information is achievable. The field contains the text of the object depends on the definition of alarm parameters, it is uncertain, This object can not access provisions. | 1.3.6.1.4.1.17409.1.2.4 | DisplayString | not-accessible | optional |
| commonIdent OBJECT-IDENTITY | 1.3.6.1.4.1.17409.1.3 | |||
| commonAdminGroup OBJECT-IDENTITY | 1.3.6.1.4.1.17409.1.3.1 | |||
| commonNELogicalID OBJECT-TYPE The logic of the designated NE identifier (LogicID), the values and attributes of other unrelated NE. This target value should be stored in non-volatile memory. | 1.3.6.1.4.1.17409.1.3.1.1 | OCTET STRING (SIZE(0..40)) | read-write | mandatory |
| commonNEVendor OBJECT-TYPE NE equipment manufacturers. | 1.3.6.1.4.1.17409.1.3.1.2 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| commonNEModelNumber OBJECT-TYPE NE equipment models. | 1.3.6.1.4.1.17409.1.3.1.3 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| commonNESerialNumber OBJECT-TYPE NE equipment serial numbers. | 1.3.6.1.4.1.17409.1.3.1.4 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| commonNEVendorInfo OBJECT-TYPE NE equipment suppliers other special designated information. | 1.3.6.1.4.1.17409.1.3.1.5 | DisplayString (SIZE(0..255)) | read-only | optional |
| commonNEStatus OBJECT-TYPE With 7.5.4 STATRESP PDU parameters in the corresponding Status Bit 0: CHNLRQST Bit 1: CNTNRM Bit 2: CNTCUR Bit 3: MAJOR ALARMS Bit 4: MINOR ALARMS Bit 5: RSVD1 Bit 6: RSVD2 Bit 7: RSVD3 | 1.3.6.1.4.1.17409.1.3.1.6 | OCTET STRING (SIZE(1)) | read-only | mandatory |
| commonReset OBJECT-TYPE Write'1 'will be reset NE equipment, the value will be included in other non-functional. Reading this object return value'1 ', had no effect on equipment. | 1.3.6.1.4.1.17409.1.3.1.7 | INTEGER {reset(1)} | read-write | mandatory |
| commonAlarmDetectionControl OBJECT-TYPE This object used to control the Alarm Detection NE. | 1.3.6.1.4.1.17409.1.3.1.8 | INTEGER {detectionDisabled(1), detectionEnabled(2), detectionEnabledAndRegenerate(3)} | read-write | mandatory |
| commonNetworkAddress OBJECT-TYPE NE network IP address, NE produce Trap should include this address. This value should be stored in nonvolatile memory. This value can be registered through the MAC order or through local vendors to set up Interface. | 1.3.6.1.4.1.17409.1.3.1.9 | IpAddress | read-only | mandatory |
| commonCheckCode OBJECT-TYPE This target for the detection transponder code configuration of the report. The calculation includes detection code transponder (including management equipment) and the physical configuration parameters stored in non-volatile memory of all the parameters. The detection algorithm calculated by the vendor code provisions. The object should be kept in the value of non-volatile memory, the response thinks highly activated, will be recalculated and re-testing code and the value prior to the commencement of comparison to determine whether or should haveһ��hfcColdStart hfcWarmStart traps. When write this object (SetRequest), the detection code will be recalculated and fill the SetRequest in response to the GetResponse. At this time, will not produce or hfcWarmStart traps hfcColdStart. | 1.3.6.1.4.1.17409.1.3.1.10 | INTEGER | read-write | mandatory |
| commonTrapCommunityString OBJECT-TYPE Definition of Community Trap string. The default value is' public '. The value of this object should be stored in non-volatile memory. | 1.3.6.1.4.1.17409.1.3.1.11 | OCTET STRING (SIZE(0..64)) | read-write | mandatory |
| commonTamperStatus OBJECT-TYPE The safety report NE switching equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in the table. Intact that normal, expressed alarm compromised. | 1.3.6.1.4.1.17409.1.3.1.12 | INTEGER {intact(1), compromised(2)} | read-only | optional |
| commonInternalTemperature OBJECT-TYPE NE equipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table. | 1.3.6.1.4.1.17409.1.3.1.13 | INTEGER (-128..127) | read-only | optional |
| commonTime OBJECT-TYPE NE of the POSIX said that the current time (since at 0:00 on January 1, 1970 since the seconds). | 1.3.6.1.4.1.17409.1.3.1.14 | INTEGER | read-write | optional |
| commonVarBindings OBJECT-TYPE This object can be said to receive SNMP information NE variables bundled the largest number of tables. Value: 0 indicated no restrictions on the maximum number bundled. | 1.3.6.1.4.1.17409.1.3.1.15 | INTEGER | read-only | mandatory |
| commonResetCause OBJECT-TYPE NE said the reasons for the recent reduction. | 1.3.6.1.4.1.17409.1.3.1.16 | INTEGER {other(1), powerup(2), command(3), watchdog(4), craft(5)} | read-only | mandatory |
| commonCraftStatus OBJECT-TYPE NE local object that this interface (such as RS232 or RS485 interface) state. NE does not necessarily have to support the local interface. NE local interface without affecting the state of its MAC interface functions; If we do not support the local interface, and its value is disconnected. | 1.3.6.1.4.1.17409.1.3.1.17 | INTEGER {disconnected(1), connected(2)} | read-only | mandatory |
| commonDeviceOID OBJECT-TYPE This OID object as a pointer, the equipment was used at MIB (such as Node, two-way amplifier, etc). | 1.3.6.1.4.1.17409.1.3.1.18 | OBJECT IDENTIFIER | read-only | optional |
| commonDeviceId OBJECT-TYPE The contents of this object by the designated by the equipment vendors, manufacturers and products it contains special ASCII text messages. | 1.3.6.1.4.1.17409.1.3.1.19 | OCTET STRING (SIZE(32)) | read-only | optional |
| commondownload OBJECT-TYPE | 1.3.6.1.4.1.17409.1.3.1.20 | INTEGER {reset(1)} | read-write | mandatory |
| commonAdminUseRf OBJECT-IDENTITY | 1.3.6.1.4.1.17409.1.3.2 | |||
| commonMACGroup OBJECT-IDENTITY | 1.3.6.1.4.1.17409.1.3.2.1 | |||
| commonMacAddress OBJECT-IDENTITY | 1.3.6.1.4.1.17409.1.3.2.1.1 | |||
| commonPhysAddress OBJECT-TYPE NE MAC (physical) address. | 1.3.6.1.4.1.17409.1.3.2.1.1.1 | OCTET STRING | read-only | mandatory |
| commonMaxMulticastAddresses OBJECT-TYPE NE equipment to support the greatest number of multicast addresses. | 1.3.6.1.4.1.17409.1.3.2.1.1.2 | INTEGER (4..255) | read-only | mandatory |
| commonMulticastAddressTable OBJECT-TYPE Multicast addresses Table, the value of this object should be stored in nonvolatile memory. | 1.3.6.1.4.1.17409.1.3.2.1.1.3 | not-accessible | mandatory | |
| commonMulticastAddressEntry OBJECT-TYPE Multicast addresses Table Head. | 1.3.6.1.4.1.17409.1.3.2.1.1.3.1 | not-accessible | mandatory | |
| commonMulticastAddressIndex OBJECT-TYPE Multicast addresses Index. | 1.3.6.1.4.1.17409.1.3.2.1.1.3.1.1 | INTEGER (1..255) | read-only | mandatory |
| commonMulticastAddressNumber OBJECT-TYPE Multicast addresses,I/Gbit | 1.3.6.1.4.1.17409.1.3.2.1.1.3.1.2 | OCTET STRING (SIZE(6)) | read-write | mandatory |
| commonBackoffParams OBJECT-IDENTITY | 1.3.6.1.4.1.17409.1.3.2.1.2 | |||
| commonBackoffPeriod OBJECT-TYPE Backoff algorithm benchmark time (ms), initialize the default value of 6 ms. The value of this object should be stored in non-volatile memory. | 1.3.6.1.4.1.17409.1.3.2.1.2.1 | INTEGER (0..16383) | read-write | mandatory |
| commonACKTimeoutWindow OBJECT-TYPE NE awaiting HE overtime to send ACK response time (ms), initialize the default value is 19 ms. The value of this object should be stored in non-volatile memory. | 1.3.6.1.4.1.17409.1.3.2.1.2.2 | INTEGER (0..255) | read-write | mandatory |
| commonMaximumMACLayerRetries OBJECT-TYPE NE data packets sent the greatest number of re-examination. Initialize the default value is 16. The value of this object should be stored in non-volatile memory. | 1.3.6.1.4.1.17409.1.3.2.1.2.3 | INTEGER (0..255) | read-write | mandatory |
| commonMaxPayloadSize OBJECT-TYPE From top to bottom line channel packet supported by the largest payload (payload) the length of. | 1.3.6.1.4.1.17409.1.3.2.1.2.4 | INTEGER | read-only | mandatory |
| commonBackoffMinimumExponent OBJECT-TYPE The standards body of the MAC layer specification definition of the smallest backoff algorithm index value, default values for 6. This value may not exceed commonBackoffMaximumValue value. The value of this object should be stored in non-volatile memory. | 1.3.6.1.4.1.17409.1.3.2.1.2.5 | INTEGER (0..15) | read-write | mandatory |
| commonBackoffMaximumExponent OBJECT-TYPE The body of the MAC layer standard definition of backoff algorithm for standardizing the largest index value, the default value is 15. This value shall be not less than commonBackoffMinimum value. The value of this object should be stored in non-volatile memory. | 1.3.6.1.4.1.17409.1.3.2.1.2.6 | INTEGER (0..15) | read-write | mandatory |
| commonMacStats OBJECT-IDENTITY | 1.3.6.1.4.1.17409.1.3.2.1.3 | |||
| commonForwardPathLOSEvents OBJECT-TYPE LOS downlink channel in the number of reset to 0. | 1.3.6.1.4.1.17409.1.3.2.1.3.1 | Counter | read-write | optional |
| commonForwardPathFramingErrors OBJECT-TYPE Downlink Channel frames wrong number reset to 0. | 1.3.6.1.4.1.17409.1.3.2.1.3.2 | Counter | read-write | optional |
| commonForwardPathCRCErrors OBJECT-TYPE CRC errors down the number of reset to 0. | 1.3.6.1.4.1.17409.1.3.2.1.3.3 | Counter | read-write | optional |
| commonInvalidMacCmds OBJECT-TYPE Invalid MAC layer order wrong number reset to 0. | 1.3.6.1.4.1.17409.1.3.2.1.3.4 | Counter | read-write | optional |
| commonBackwardPathCollisionTimes OBJECT-TYPE Uplink Packet collision frequency, reset to 0. | 1.3.6.1.4.1.17409.1.3.2.1.3.5 | Counter | read-write | optional |
| commonRfGroup OBJECT-IDENTITY | 1.3.6.1.4.1.17409.1.3.2.2 | |||
| commonReturnPathFrequency OBJECT-TYPE Channel uplink frequency units Hz. The value of this object should be stored in non-volatile memory. | 1.3.6.1.4.1.17409.1.3.2.2.1 | INTEGER (0..1000000000) | read-only | mandatory |
| commonForwardPathFrequency OBJECT-TYPE Downlink frequency channel, flat Hz. The value of this object should be stored in non-volatile memory. | 1.3.6.1.4.1.17409.1.3.2.2.2 | INTEGER (0..1000000000) | read-only | mandatory |
| commonProvisionedReturnPowerLevel OBJECT-TYPE Upstream channel power levels and units for dBuV. When the internal use of this value will be rounded to the nearest support value. Reading return to this subject when the actual value rather than rounding value. The value of this object should be stored in non-volatile memory. | 1.3.6.1.4.1.17409.1.3.2.2.3 | INTEGER (0..127) | read-write | mandatory |
| commonForwardPathReceiveLevel OBJECT-TYPE Downlink Channel receive power levels, units dBuV. | 1.3.6.1.4.1.17409.1.3.2.2.4 | INTEGER (0..127) | read-only | optional |
| commonMaxReturnPower OBJECT-TYPE The largest upstream channel power levels and units for dBuV. The value of this object should be stored in non-volatile memory. | 1.3.6.1.4.1.17409.1.3.2.2.5 | INTEGER (0..127) | read-write | mandatory |
| commonAdminUseEthernet OBJECT-IDENTITY | 1.3.6.1.4.1.17409.1.3.3 | |||
| commonAgentGroup OBJECT-IDENTITY | 1.3.6.1.4.1.17409.1.3.3.1 | |||
| commonAgentBootWay OBJECT-TYPE Starting Method Acting | 1.3.6.1.4.1.17409.1.3.3.1.1 | INTEGER {bootDefault(1), bootBOOTP(2), bootTFTP(3)} | read-write | mandatory |
| commonAgentReset OBJECT-TYPE Acting Restart, write'1 'will enable agents to restart, the value will be included in other non-functional. Reading this object return value'1 ', the agent had no effect on. | 1.3.6.1.4.1.17409.1.3.3.1.2 | INTEGER {reset(1)} | read-write | mandatory |
| commonAgentMaxTraps OBJECT-TYPE Acting detected alarm when sent to the management of the largest number of TRAP, 0 that manufacturers use the default default values. | 1.3.6.1.4.1.17409.1.3.3.1.3 | INTEGER | read-write | mandatory |
| commonAgentTrapMinInterval OBJECT-TYPE Acting TRAP send the minimum spacing units for s. | 1.3.6.1.4.1.17409.1.3.3.1.4 | INTEGER | read-write | mandatory |
| commonAgentTrapMaxInterval OBJECT-TYPE Acting TRAP send the largest spacing units for s. | 1.3.6.1.4.1.17409.1.3.3.1.5 | INTEGER | read-write | mandatory |
| commonTrapAck OBJECT-TYPE The variables used to notify Snmp agents, it issued the warning Trap has received information management console, do not have to re-hair. The content of the variables in alarmLogInformation MIB and the same warning. Agents received after the adoption of alarmLogInformation management can clearly know the host response is a warning which Trap information, thereby stop the alarm information re the Trap. | 1.3.6.1.4.1.17409.1.3.3.1.6 | OCTET STRING (SIZE(17..255)) | read-write | optional |
| commonAgentTrapTable OBJECT-TYPE Acting Information Table TRAP. | 1.3.6.1.4.1.17409.1.3.3.1.7 | not-accessible | mandatory | |
| commonAgentTrapEntry OBJECT-TYPE Acting Head TRAP Information Table. | 1.3.6.1.4.1.17409.1.3.3.1.7.1 | not-accessible | mandatory | |
| commonAgentTrapIndex OBJECT-TYPE TRAP Table Index. | 1.3.6.1.4.1.17409.1.3.3.1.7.1.1 | INTEGER | read-only | mandatory |
| commonAgentTrapIP OBJECT-TYPE When the purpose of the TRAP host's IP address. | 1.3.6.1.4.1.17409.1.3.3.1.7.1.2 | IpAddress | read-write | mandatory |
| commonAgentTrapCommunity OBJECT-TYPE Send the Community string TRAP. | 1.3.6.1.4.1.17409.1.3.3.1.7.1.3 | DisplayString (SIZE(0..64)) | read-write | mandatory |
| commonAgentTrapStatus OBJECT-TYPE It said the opening of the TRAP. | 1.3.6.1.4.1.17409.1.3.3.1.7.1.4 | INTEGER {commonAgentTrapEnable(1), commonAgentTrapDisable(2)} | read-write | mandatory |
| commonDeviceGroup OBJECT-IDENTITY | 1.3.6.1.4.1.17409.1.3.3.2 | |||
| commonDeviceNum OBJECT-TYPE The agent said that the current management is the number of devices. | 1.3.6.1.4.1.17409.1.3.3.2.1 | INTEGER | read-write | mandatory |
| commonDeviceInfoTable OBJECT-TYPE Acting is currently public information management equipment List. | 1.3.6.1.4.1.17409.1.3.3.2.2 | not-accessible | mandatory | |
| commonDeviceInfoEntry OBJECT-TYPE Acting is currently public information management equipment list Table Head. | 1.3.6.1.4.1.17409.1.3.3.2.2.1 | not-accessible | mandatory | |
| commonDeviceSlot OBJECT-TYPE Acting is currently under the management of the equipment list of public information table Index. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.1 | INTEGER | read-only | mandatory |
| commonDevicesID OBJECT-TYPE Designated equipment manufacturers logo. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.2 | OCTET STRING (SIZE(0..40)) | read-only | mandatory |
| commonDeviceVendor OBJECT-TYPE Equipment manufacturers. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.3 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| commonDeviceModelNumber OBJECT-TYPE Equipment Model. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.4 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| commonDeviceSerialNumber OBJECT-TYPE The string of equipment. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.5 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| commonDeviceVendorInfo OBJECT-TYPE Equipment suppliers of other special designated information. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.6 | DisplayString (SIZE(0..255)) | read-only | optional |
| commonDeviceStatus OBJECT-TYPE The state equipment Bit 0: RSVD0 Bit 1: RSVD1 Bit 2: RSVD2 Bit 3: MAJOR ALARMS Bit 4: MINOR ALARMS Bit 5: RSVD5 Bit 6: RSVD6 Bit 7: RSVD7 | 1.3.6.1.4.1.17409.1.3.3.2.2.1.7 | OCTET STRING (SIZE(1)) | read-only | mandatory |
| commonDeviceReset OBJECT-TYPE Write'1 'will be reset equipment, other values will be written into the non-functional. Reading this object return value'1 ', had no effect on equipment. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.8 | INTEGER {reset(1)} | read-write | mandatory |
| commonDeviceAlarmDetectionControl OBJECT-TYPE This object used to control equipment Alarm Detection. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.9 | INTEGER {detectionDisabled(1), detectionEnabled(2), detectionEnabledAndRegenerate(3)} | read-write | mandatory |
| commonDeviceMACAddress OBJECT-TYPE Equipment MAC address. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.10 | IpAddress | read-only | mandatory |
| commonDeviceTamperStatus OBJECT-TYPE Report of the safety switch equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in the table. Intact that normal, expressed alarm compromised. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.11 | INTEGER {intact(1), compromised(2)} | read-only | optional |
| commonDeviceInternalTemperature OBJECT-TYPE Equipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.12 | INTEGER (-128..127) | read-only | optional |
| commonDeviceResetCause OBJECT-TYPE Equipment that the reasons for the recent reduction. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.13 | INTEGER {other(1), powerup(2), command(3), watchdog(4), craft(5)} | read-only | mandatory |
| commonDeviceCraftStatus OBJECT-TYPE This object interface that local equipment (such as RS232 or RS485 interface) state. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.14 | INTEGER {disconnected(1), connected(2)} | read-only | mandatory |
| commonDevicesOID OBJECT-TYPE Goals identifier string, point to a concrete realization of the equipment. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.15 | OBJECT IDENTIFIER | read-only | mandatory |
| commonDeviceAcct OBJECT-TYPE Equipment that the accumulated work time, units of s. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.16 | Counter | read-only | optional |
| commonDeviceName OBJECT-TYPE Equipment Name. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.17 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| commonDeviceMFD OBJECT-TYPE Date of production equipment. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.18 | DisplayString (SIZE(10)) | read-only | mandatory |
| commonDeviceFW OBJECT-TYPE Firmware information equipment. | 1.3.6.1.4.1.17409.1.3.3.2.2.1.19 | DisplayString (SIZE(0..255)) | read-only | mandatory |
| oaIdent OBJECT-IDENTITY | 1.3.6.1.4.1.17409.1.11 | |||
| oaVendorOID OBJECT-TYPE This object provides manufacturers of optical amplifier MIB expansion. Without the expansion, this should be targeting at the optical amplifier nodes oaIdent. | 1.3.6.1.4.1.17409.1.11.1 | OBJECT IDENTIFIER | read-only | optional |
| oaOutputOpticalPower OBJECT-TYPE The output optical power units to 0.1 dBm, the object attributes required to register an entry MIB. | 1.3.6.1.4.1.17409.1.11.2 | INTEGER (0..65535) | read-only | mandatory |
| oaInputOpticalPower OBJECT-TYPE Input optical power units to 0.1 dBm, the object attributes required to register an entry MIB. | 1.3.6.1.4.1.17409.1.11.3 | INTEGER (-128..127) | read-only | mandatory |
| oaPumpTable OBJECT-TYPE EDFA laser pump Information Table. | 1.3.6.1.4.1.17409.1.11.4 | not-accessible | mandatory | |
| oaPumpEntry OBJECT-TYPE Each laser-pumped optical amplifier Information Table Head. | 1.3.6.1.4.1.17409.1.11.4.1 | not-accessible | mandatory | |
| oaPumpIndex OBJECT-TYPE Laser-pumped optical amplifier index value. | 1.3.6.1.4.1.17409.1.11.4.1.1 | INTEGER | read-only | mandatory |
| oaPumpBIAS OBJECT-TYPE The pump laser bias current, flat mA, this attribute MIB objects require an entry in the register. | 1.3.6.1.4.1.17409.1.11.4.1.2 | INTEGER (0..65535) | read-only | mandatory |
| oaPumpTEC OBJECT-TYPE Current laser pump refrigeration unit is 0.01 A, this attribute MIB objects require an entry in the register. | 1.3.6.1.4.1.17409.1.11.4.1.3 | INTEGER (-32768..32767) | read-only | optional |
| oaPumpTemp OBJECT-TYPE Laser pump temperature, units of 0.10 C, this attribute MIB objects require an entry in the register. | 1.3.6.1.4.1.17409.1.11.4.1.4 | INTEGER (0..32768) | read-only | mandatory |
| oaNumberDCPowerSupply OBJECT-TYPE The number of internal DC power supply, 0 expressed transponder does not support this function. | 1.3.6.1.4.1.17409.1.11.5 | INTEGER (0..16) | read-only | mandatory |
| oaDCPowerSupplyMode OBJECT-TYPE Power supply mode: load sharing, standby switching or an independent power supply. | 1.3.6.1.4.1.17409.1.11.6 | INTEGER {loadsharing(1), switchedRedundant(2), aloneSupply(3)} | read-only | optional |
| oaDCPowerTable OBJECT-TYPE DC Power Information Table. | 1.3.6.1.4.1.17409.1.11.7 | not-accessible | mandatory | |
| oaDCPowerEntry OBJECT-TYPE DC Power Information Table Head. | 1.3.6.1.4.1.17409.1.11.7.1 | not-accessible | mandatory | |
| oaDCPowerIndex OBJECT-TYPE DC Power Index. | 1.3.6.1.4.1.17409.1.11.7.1.1 | INTEGER | read-only | mandatory |
| oaDCPowerVoltage OBJECT-TYPE Supply voltage, the unit is 0.1 V. This attribute MIB objects require an entry in the register. | 1.3.6.1.4.1.17409.1.11.7.1.2 | INTEGER (-32768..32767) | read-only | mandatory |
| oaDCPowerCurrent OBJECT-TYPE Electricity power supply unit is 0.01 A. This attribute MIB objects require an entry in the register. | 1.3.6.1.4.1.17409.1.11.7.1.3 | INTEGER (0..65535) | read-only | mandatory |
| oaDCPowerName OBJECT-TYPE Indicate the name of the power supply, for example: 24 V DC power supply. This field value by the user, should at least be marked with a number of power supply voltage and distinguish between each other. When the object of this table have a warning, that this object should be put into the name of alarmText hfcAlarmEvent traps in the target. | 1.3.6.1.4.1.17409.1.11.7.1.4 | DisplayString | read-only | mandatory |
| oaOutputOpticalPowerSet OBJECT-TYPE The output optical power control ,units to 0.1 dBm | 1.3.6.1.4.1.17409.1.11.11 | INTEGER (0..65535) | read-write | mandatory |
| oaGainSet OBJECT-TYPE units to 0.1 dB | 1.3.6.1.4.1.17409.1.11.12 | INTEGER (0..65535) | read-write | mandatory |
| powerSupplyStatusA OBJECT-TYPE Returns the operating status of power supply A. | 1.3.6.1.4.1.17409.1.11.32 | INTEGER {undefined(0), nominal(1), failure(2), notInstalled(3)} | read-only | current |
| powerSupplyStatusB OBJECT-TYPE Returns the operating status of power supply B. | 1.3.6.1.4.1.17409.1.11.33 | INTEGER {undefined(0), nominal(1), failure(2), notInstalled(3)} | read-only | current |
Notifications
| Name | OID | Status |
|---|---|---|
| hfcColdStart NOTIFICATION-TYPE HfcColdStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement may have changed. This trap only after the success of transponder sent registration. | 1.3.6.1.4.1.17409.1.0.0 | |
| hfcAlarmEvent NOTIFICATION-TYPE When detected in the event of alarm information sent this trap, whether bundled alarmText variable parameter under warning object to determine. Some of the parameters only need to bind the alarm first three variables. | 1.3.6.1.4.1.17409.1.0.1 | |
| hfcWarmStart NOTIFICATION-TYPE HfcWarmStart traps that are sent to re-initialization protocol entities, and entities agent configuration or agreement has not changed. This trap only after the completion of transponder sent registration. | 1.3.6.1.4.1.17409.1.0.2 |