MIBs Depot

NEXANS-BM-MIB

Registered at
1.3.6.1.4.1.266.20
Last updated
2014-01-29 00:00
Organization
Nexans Advanced Networking Solutions
Revisions
2014-01-29 00:00
Namespace
nexans
Source file
NEXANS-BM-MIB
Digest
sha256:e6411c1394a15bcda57591e09bbe66b182649fc5b30e7c4f7924606072d2ca87

Description

MIB for Nexans switches

Contact

h.theissen@nexans.com

Imports

FromSymbols
NEXANS-MIBnexansANS
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, MacAddress, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

NEXANS-BM-MIB
NEXANS-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
bmTraps
OBJECT-IDENTITY
1.3.6.1.4.1.266.20.0
bmSwitchInfo
OBJECT-IDENTITY
1.3.6.1.4.1.266.20.1
infoDescr
OBJECT-TYPE
The ordering description of the switch
1.3.6.1.4.1.266.20.1.1DisplayString (SIZE(0..40))read-onlycurrent
infoType
OBJECT-TYPE
The infoType indentifies the product familie of this switch. Refer to NEXANS-MIB for the currently defined families
1.3.6.1.4.1.266.20.1.2Integer32read-onlycurrent
infoProductNo
OBJECT-TYPE
The product number of the switch (8830xxxx)
1.3.6.1.4.1.266.20.1.3DisplayString (SIZE(0..8))read-onlycurrent
infoSerie
OBJECT-TYPE
The production series of the switch
1.3.6.1.4.1.266.20.1.4DisplayString (SIZE(1..6))read-onlycurrent
infoSeriesNo
OBJECT-TYPE
The production number of the switch
1.3.6.1.4.1.266.20.1.5DisplayString (SIZE(1..6))read-onlycurrent
infoManufactureDate
OBJECT-TYPE
The manufacturing date of the switch. The display format is dd.mm.jjjj
1.3.6.1.4.1.266.20.1.6DisplayString (SIZE(10))read-onlycurrent
infoSwitchHardwareVersion
OBJECT-TYPE
The hardware version of the base switch.
1.3.6.1.4.1.266.20.1.7DisplayString (SIZE(1..6))read-onlycurrent
infoMgmtHardwareVersion
OBJECT-TYPE
The hardware version of the plug-in management module.
1.3.6.1.4.1.266.20.1.8DisplayString (SIZE(1..6))read-onlycurrent
infoMgmtFirmwareVersion
OBJECT-TYPE
The firmware version of the management module.
1.3.6.1.4.1.266.20.1.9DisplayString (SIZE(1..20))read-onlycurrent
infoNoOfPorts
OBJECT-TYPE
The number of switching ports within the system. This includes all user and uplink ports.
1.3.6.1.4.1.266.20.1.10Integer32read-onlycurrent
infoNoOfReboots
OBJECT-TYPE
The number of reboots since the manufacturing date. This counter can't be cleared by any admin command.
1.3.6.1.4.1.266.20.1.11Counter32read-onlycurrent
infoTemperature
OBJECT-TYPE
The case temperature in degree Celsius of the switch.
1.3.6.1.4.1.266.20.1.12Integer32read-onlycurrent
infoTemperatureMaxAllowed
OBJECT-TYPE
The upper limit of the allowed temperature range in degree Celsius. If the current temperature indicated by infoTemperature exceeds infoTemperatureMaxAllowed, the switch sends an switchOverTemperature alarm trap.
1.3.6.1.4.1.266.20.1.13Integer32read-onlycurrent
infoPowerVoltage2500
OBJECT-TYPE
The 2.5 volt supply voltage in millivolts. The allowed range is 2300...2700 millivolts.
1.3.6.1.4.1.266.20.1.14Integer32read-onlycurrent
infoPowerVoltage3300
OBJECT-TYPE
The 3.3 volt supply voltage in millivolts. The allowed range is 3100...3500 millivolts.
1.3.6.1.4.1.266.20.1.15Integer32read-onlycurrent
infoUnauthIpAddr
OBJECT-TYPE
The source IP address of the station which generated the last authentication failure. The infoUnauthAddr is also reported in the switchMgmtAuthFailure alarm trap.
1.3.6.1.4.1.266.20.1.16IpAddressread-onlycurrent
infoSecurityFailMacAddr
OBJECT-TYPE
The source MAC address of the station which has generated a the last port security failure. The infoSecurityFailMacAddr is also reported in the portSecurityFailure alarm trap.
1.3.6.1.4.1.266.20.1.17DisplayString (SIZE(0..12))read-onlycurrent
infoNewMacAddr
OBJECT-TYPE
The last new source MAC address seen on a port witch has portsecurity enabled. The infoNewMacAddr is also reported in the newMacAddress trap.
1.3.6.1.4.1.266.20.1.18DisplayString (SIZE(0..12))read-onlycurrent
infoPoeInputVoltage
OBJECT-TYPE
The current PoE input voltage delivered from the power supply.
1.3.6.1.4.1.266.20.1.19Integer32read-onlycurrent
infoPoeInputPower
OBJECT-TYPE
The current PoE input power delivered from the power supply.
1.3.6.1.4.1.266.20.1.20Integer32read-onlycurrent
infoAlarmStateM1
OBJECT-TYPE
The current state of the industrial alarm output M1.
1.3.6.1.4.1.266.20.1.21INTEGER {notSupported(1), alarmOff(2), alarmOn(3), alarmOnLinkDown(4), alarmOnForced(5), alarmOffForced(6), alarmOnPowerSupplyS1(7), alarmOnPowerSupplyS2(8), alarmOnPowerSupplyS1orS2(9), alarmOnFunctionInputShorted(10), alarmOnFunctionInputOpen(11), alarmOnRemoteFunctionInput(12), alarmOnRemoteAlarmDestTable(13), alarmOnLocalAlarmDestTable(14), alarmContactForcedShorted(15), alarmContactForcedOpen(16)}read-onlycurrent
infoAlarmStateM2
OBJECT-TYPE
The current state of the industrial alarm output M2.
1.3.6.1.4.1.266.20.1.22INTEGER {notSupported(1), alarmOff(2), alarmOn(3), alarmOnLinkDown(4), alarmOnForced(5), alarmOffForced(6), alarmOnPowerSupplyS1(7), alarmOnPowerSupplyS2(8), alarmOnPowerSupplyS1orS2(9), alarmOnFunctionInputShorted(10), alarmOnFunctionInputOpen(11), alarmOnRemoteFunctionInput(12), alarmOnRemoteAlarmDestTable(13), alarmOnLocalAlarmDestTable(14), alarmContactForcedShorted(15), alarmContactForcedOpen(16)}read-onlycurrent
infoLastTftpMessage
OBJECT-TYPE
The message of the last successful or failed TFTP transfer. This does not include TFTP transfers executed from Device Manager.
1.3.6.1.4.1.266.20.1.23DisplayString (SIZE(0..80))accessible-for-notifycurrent
infoLastSfpEventMessage
OBJECT-TYPE
The last event message from one of the available SFP modules.
1.3.6.1.4.1.266.20.1.24DisplayString (SIZE(0..80))accessible-for-notifycurrent
infoLastInternalMgmtWarning
OBJECT-TYPE
The last internal management warning message.
1.3.6.1.4.1.266.20.1.25DisplayString (SIZE(0..80))accessible-for-notifycurrent
infoFunctionInputStateF1
OBJECT-TYPE
The current state of the function input F1.
1.3.6.1.4.1.266.20.1.26INTEGER {notSupported(1), functionInputShorted(2), functionInputOpen(3)}read-onlycurrent
infoTotalConfigChanges
OBJECT-TYPE
The number of total configurations changes.
1.3.6.1.4.1.266.20.1.27Counter32read-onlycurrent
bmSwitchAdmin
OBJECT-IDENTITY
1.3.6.1.4.1.266.20.2
adminReset
OBJECT-TYPE
Writing this object causes the switch to perform a reset operation. The following reset types are supported. Set Values: resetCounters(2) This action resets all error and statistic counters to zero. This actions will NOT reboot the switch. rebootSwitch(3) This action resets switch and management. All counters, timers and other volatile data are reset to there power-up values stored in flash. This actions will reboot the switch. rebootToFactoryDefaults(4) This action resets switch and management. All volatile and nonvolatile data are reset to there power-up or factory default values. This actions will reboot the switch. renewIpAndVlanParameter(5) This action reinitializes the IP and VLAN module of the switch so that the actually set IP and VLAN parameters will take affect. This actions will NOT reboot the switch. Get values: resetIdle(1) Reading this object will allways return resetIdle(1).
1.3.6.1.4.1.266.20.2.1INTEGER {resetIdle(1), resetCounters(2), rebootSwitch(3), rebootToFactoryDefaults(4), renewIpAndVlanParameter(5)}read-writecurrent
adminAgentDhcp
OBJECT-TYPE
If set to enable(1), the switch tries to get his IP parameter via DHCP. If set to disable(2), the switch uses the IP parameters defined with adminIpAddress, adminDefRouterIpAddress and adminNetmask. Changes of this value will take affect after the next switch reboot or after setting adminReset to renewIpAndVlanParameter(5).
1.3.6.1.4.1.266.20.2.2INTEGER {enable(1), disable(2)}read-writecurrent
adminAgentIpAddress
OBJECT-TYPE
The IP address of the switch agent's ethernet interface. If the value of adminDHCP is enable(1) this value is read-only. Changes of this value will take affect after the next switch reboot or after setting adminReset to renewIpAndVlanParameter(5).
1.3.6.1.4.1.266.20.2.3IpAddressread-writecurrent
adminAgentPhysAddress
OBJECT-TYPE
The Ethernet MAC address of the switch agent.
1.3.6.1.4.1.266.20.2.4MacAddressread-onlycurrent
adminAgentDefRouterIpAddress
OBJECT-TYPE
The IP address of the default Router. If the value of adminDHCP is enable(1) this value is read-only. Changes of this value will take affect after the next switch reboot or after setting adminReset to renewIpAndVlanParameter(5).
1.3.6.1.4.1.266.20.2.5IpAddressread-writecurrent
adminAgentNetmask
OBJECT-TYPE
The IP Netmask of the connected network. If the value of adminDHCP is enable(1) this value is read-only. Changes of this value will take affect after the next switch reboot or after setting adminReset to renewIpAndVlanParameter(5).
1.3.6.1.4.1.266.20.2.6IpAddressread-writecurrent
adminAgentDhcpServerIpAddress
OBJECT-TYPE
The IP address of the last used DHCP server.
1.3.6.1.4.1.266.20.2.7IpAddressread-onlycurrent
adminAgentVlanId
OBJECT-TYPE
The VLAN-ID assigned to the agent. Changes of this value will take affect after the next switch reboot or after setting adminReset to renewIpAndVlanParameter(5).
1.3.6.1.4.1.266.20.2.8Integer32 (1..4095)read-writecurrent
adminAgentPrioValue
OBJECT-TYPE
The IEEE802.1Q priority value and queue assigned to all frames transmitted by the agent. The definition between value, service class and queue are as follows: 0=Best Effort (queue=0), 1=Background (queue=0), 2=Reserved (queue=1), 3=Excellent Effort (queue=1), 4=Controlled Load (queue=2), 5=Video (queue=2), 6=Voice (queue=3), 7=Network Control (queue=3)
1.3.6.1.4.1.266.20.2.9Integer32 (0..7)read-writecurrent
adminAddrAgingTimeMinutes
OBJECT-TYPE
The timeout period in minutes for aging out dynamically learned MAC addresses . The allowed range is 1 minute to 68 minutes.
1.3.6.1.4.1.266.20.2.10Integer32 (1..68)read-writecurrent
adminSwitchPortMirror
OBJECT-TYPE
If set to enable(1), the switch doesn't use address learning. This affects that any received packet will be forwarded to all ports of the particular VLAN. The switch acts like a hub within each VLAN.
1.3.6.1.4.1.266.20.2.11INTEGER {enable(1), disable(2)}read-writecurrent
adminMgmtAccessList
OBJECT-TYPE
If set to enableForNexManAccess(2) or enableForAllAccess(3), the switch only accepts read or write requests from IP addresses which are listed in the management accesslist.
1.3.6.1.4.1.266.20.2.12INTEGER {disable(1), enableForNexManAccess(2), enableForAllAccess(3), enableForSnmpAccess(4)}read-writecurrent
adminSwitchPoEPowerLimit
OBJECT-TYPE
The limit for the POE input power from the power supply in VA. If the current power exceeds this value a overload conditions occurs and the inline power for the highest port number will be switched off.
1.3.6.1.4.1.266.20.2.13Integer32read-writecurrent
adminSwitchVlanTableMode
OBJECT-TYPE
If set to staticMode(1) or staticModeVlans64(3) any existing VLAN table entry must be removed manually by management. With staticMode(1) total 16 VLAN-ID's and with staticModeVlans64(3) total 64 VLAN-ID's are supported. If set to dynamicMode(2) all unused VLAN-ID's are removed automatically by the switch. This means, that all VLAN-ID's not assigned to a port Default-VLAND or to the Unsecure-VLAN will be removed.
1.3.6.1.4.1.266.20.2.14INTEGER {staticMode(1), dynamicMode(2), staticModeVlans64(3), staticModePortBased(4)}read-writecurrent
adminUnsecureVlanId
OBJECT-TYPE
The VLAN-ID of the unsecure VLAN
1.3.6.1.4.1.266.20.2.15Integer32 (1..4095)read-writecurrent
adminDot1xAuthFailureVlanId
OBJECT-TYPE
The VLAN-ID in the case of an IEEE802.1X authentication failure. Setting the VLAN-ID to 0 disables the authentication failure VLAN.
1.3.6.1.4.1.266.20.2.16Integer32 (0..4095)read-writecurrent
adminTftpAccess
OBJECT-TYPE
If 'TFTP authentication via SNMP' is disabled, this value is allways tftpAccessDisable(1). If 'TFTP authentication via SNMP' is read/only or read/write, an this object is read, the value is tftpAccessReadOnly(2) and the agent allowes a single TFTP read access of the switch configuration. If 'TFTP authentication via SNMP' is read/write, this value can be set to tftpAccessReadWrite(3) and the agent allowes a single TFTP read or write access to the configuration or a single firmware upgrade. After finishing the TFTP transfer, this value will return to ftpAccessDisable(1) automatically. Note: If the 'NexMan authentication mode' is set to 'none', TFTP read and write access is allways allowed.
1.3.6.1.4.1.266.20.2.17INTEGER {tftpAccessDisable(1), tftpAccessReadOnly(2), tftpAccessReadWrite(3)}read-writecurrent
adminSnmpMacTableMode
OBJECT-TYPE
If set to listAllPorts(1) the BRIDGE-MIBs dot1dTpFdbTable lits MAC address of all ports. If set to listUserPortsOnly(2) the BRIDGE-MIBs dot1dTpFdbTable lits only MAC addresses of user ports. MAC addresses of uplink/downlink ports are ignored.
1.3.6.1.4.1.266.20.2.18INTEGER {listAllPorts(1), listUserPortsOnly(2)}read-writecurrent
adminAlarmM1
OBJECT-TYPE
The current setup of the industrial alarm output M1.
1.3.6.1.4.1.266.20.2.19INTEGER {notSupported(1), alarmLinkDown(2), alarmOnForced(3), alarmOffForced(4), alarmPowerSupply1Failure(5), alarmPowerSupply2Failure(6), alarmPowerSupply1or2Failure(7), alarmLocalFunctionInputShorted(8), alarmLocalFunctionInputOpen(9), alarmRemoteFunctionInput(10), alarmRemoteAlarmDestination(11), alarmLocalAlarmDestination(12), alarmForceContactShorted(13), alarmForceContactOpen(14), alarmForceContactOpenShorted(15)}read-writecurrent
adminAlarmM2
OBJECT-TYPE
The current setup of the industrial alarm output M2.
1.3.6.1.4.1.266.20.2.20INTEGER {notSupported(1), alarmLinkDown(2), alarmOnForced(3), alarmOffForced(4), alarmPowerSupply1Failure(5), alarmPowerSupply2Failure(6), alarmPowerSupply1or2Failure(7), alarmLocalFunctionInputShorted(8), alarmLocalFunctionInputOpen(9), alarmRemoteFunctionInput(10), alarmRemoteAlarmDestination(11), alarmLocalAlarmDestination(12), alarmForceContactShorted(13), alarmForceContactOpen(14), alarmForceContactOpenShorted(15)}read-writecurrent
adminMemoryCardMode
OBJECT-TYPE
If set to mcDisabled(2), the memory card is disabled but may be re-enabled later by writing mcEnabled(1). If set to mcPermanentDisabled(3), the memory card is disabled permanently and can't be re-enabled by management or any kind of hardware reset.
1.3.6.1.4.1.266.20.2.21INTEGER {notSupported(1), mcEnabled(2), mcDisabled(3), mcPermanentDisabled(4)}read-writecurrent
adminAlarmNameM1
OBJECT-TYPE
An administratively assigned name for alarm output M1. The configured name will be send as part of alarm message switchIndustrialAlarmM1.
1.3.6.1.4.1.266.20.2.22DisplayString (SIZE(0..32))read-writecurrent
adminAlarmNameM2
OBJECT-TYPE
An administratively assigned name for alarm output M1. The configured name will be send as part of alarm message switchIndustrialAlarmM2.
1.3.6.1.4.1.266.20.2.23DisplayString (SIZE(0..32))read-writecurrent
adminFunctionInputNameF1
OBJECT-TYPE
An administratively assigned name for function input F1. The configured name will be send as part of alarm message switchFunctionInputAlarm.
1.3.6.1.4.1.266.20.2.24DisplayString (SIZE(0..32))read-writecurrent
adminLedGlobalMode
OBJECT-TYPE
Set the global mode for all front side LEDs.
1.3.6.1.4.1.266.20.2.25INTEGER {ledGlobalModeNotSupported(1), ledGlobalModeStandard(2), ledGlobalModeAllOff(3), ledGlobalModeAllOn(4), ledGlobalModeMgmtOnly(5)}read-writecurrent
bmSwitchPort
OBJECT-IDENTITY
1.3.6.1.4.1.266.20.3
bmSwitchPortTable
OBJECT-TYPE
A list of port entries for the switch. The number of entries is defined by ifNumber.
1.3.6.1.4.1.266.20.3.1not-accessiblecurrent
bmSwitchPortEntry
OBJECT-TYPE
A port entry in the table containing information about a port in the switch.
1.3.6.1.4.1.266.20.3.1.1not-accessiblecurrent
portIndex
OBJECT-TYPE
A unique value for each port. Its value ranges between 1 and the value of ifNumber. The port identified by a particular value of this index is the same port as identified by the same value of ifIndex.
1.3.6.1.4.1.266.20.3.1.1.1Integer32 (1..64)read-onlycurrent
portDescr
OBJECT-TYPE
A textual string containing information about the interface. Same as ifDescr.
1.3.6.1.4.1.266.20.3.1.1.2DisplayString (SIZE(0..255))read-onlycurrent
portName
OBJECT-TYPE
An administratively assigned name for this port.
1.3.6.1.4.1.266.20.3.1.1.3DisplayString (SIZE(0..15))read-writecurrent
portAdminState
OBJECT-TYPE
A value indicating the current state of the port. A SET to this object enables (2) or disables (3) the port. The possible values returned by GET are: allwaysEnable(1) The port is always enabled (usually the uplink port). enable(2) The port is active to transmit or receive data. disable(3) The port is inactive and unable to transmit or receive data. securityDisable(4) The port has been automatically disabled because of security violation. loopDisable(5) The port has been automatically disabled because of the active loop protection. bpduDisable(6) The port has been automatically disabled because a BPDU has been received on a Spanning Tree disabled port. udldDisable(7) The port has been automatically disabled because of the UDLD function. linkFlapDisable(8) The port has been automatically disabled because of the link flap protection. errorCountDisable(9) The port has been automatically disabled because of the error counter incrementation detection. sfpErrorDisable(10) The port has been automatically disabled because of wromg SFP inserted or SFP malfunction. redundanyLoopDisable(11) The port has been automatically disabled because of loop detection while spannung tree was enabled
1.3.6.1.4.1.266.20.3.1.1.4INTEGER {allwaysEnable(1), enable(2), adminDisable(3), securityDisable(4), loopDisable(5), bpduDisable(6), udldDisable(7), linkFlapDisable(8), errorCountDisable(9), sfpErrorDisable(10), redundanyLoopDisable(11)}read-writecurrent
portSpeedDuplexSetup
OBJECT-TYPE
A value indicating the current speed and duplex link setup. Independent of portSpeedDuplexSetup the port may be disabled by portAdminState.
1.3.6.1.4.1.266.20.3.1.1.5INTEGER {autoneg(1), fix10Hdx(2), fix10Fdx(3), fix100Hdx(4), fix100Fdx(5), fix1000Hdx(7), fix1000Fdx(8), eco(9), ecoOverTemp(10), ecoPowerSave(11), fix1000fdxNoAutoneg(12)}read-writecurrent
portLinkState
OBJECT-TYPE
A value indicating the current link state.
1.3.6.1.4.1.266.20.3.1.1.6INTEGER {down(1), up10Hdx(2), up10Fdx(3), up100Hdx(4), up100Fdx(5), up1000Hdx(6), up1000Fdx(7)}read-onlycurrent
portErrorCounter
OBJECT-TYPE
Errors are usually caused by a FDX/HDX mismatch between the switch port and the connected port. If the switch detects a incrementation of this counter, he will send a portErrorCountFailure trap. The counted errors are depending on the switch type. For BM-A, BM+ and Access Switches: - Received packets with bad CRC, - Received packets with bad alignment, - Late collisions (only valid if Link State is 10HDX or 100HDX). For old BM Switches: - Received packets with bad CRC
1.3.6.1.4.1.266.20.3.1.1.7Counter32read-onlycurrent
portRemoteFault
OBJECT-TYPE
If portRemoteFault is enabled for this port, the port transmitter will be only enabled if the port receiver has a valid link (portLinkState must not be down).
1.3.6.1.4.1.266.20.3.1.1.8INTEGER {notSupported(1), enable(2), disable(3)}read-writecurrent
portDefaultVlanId
OBJECT-TYPE
The Default-VLAN-ID assigned to this port. This Default-VLAN-ID has differnt affects depending on received or transmited frames: a) All received frames, which have no VLAN-tag, will be assigned to the Default-VLAN-ID. b) All transmited frames, which belong to the Default-VLAN, are send without a VLAN-tag. If portTrunkingMode is set to dot1qTagging, all frames are transmited with a VLAN-tag, except frames which belong to the Default-VLAN-ID. Changes of this value will take affect after the next switch reboot or after setting adminReset to renewIpAndVlanParameter(5). Setting this value to 0 for a port with dot1qTagging will disable the Default-VLAN. This means, that all frames are send tagged.
1.3.6.1.4.1.266.20.3.1.1.9Integer32 (0..4095)read-writecurrent
portTrunkingMode
OBJECT-TYPE
If portTrunkingMode is set to dot1qTagging, all frames are transmited with a VLAN-tag, except frames which belong to portNativeVlanId. If portTrunkingMode is set to enableWithoutTagging, all frames are transmited without a VLAN-tag. Changes of this value will take affect after the next switch reboot or after setting adminReset to renewIpAndVlanParameter(5).
1.3.6.1.4.1.266.20.3.1.1.10INTEGER {dot1qTagging(1), disable(2), enableWithoutTagging(3)}read-writecurrent
portDot1qDefaultPrioValue
OBJECT-TYPE
The default IEEE802.1Q priority and queue assigned all frames received on this port, for which no other priorisation applies (IEEE801.1q Tag or IPv4/IPv6). The definition between value, service class and queue are as follows: 0=Best Effort (queue=0), 1=Background (queue=0), 2=Reserved (queue=1), 3=Excellent Effort (queue=1), 4=Controlled Load (queue=2), 5=Video (queue=2), 6=Voice (queue=3), 7=Network Control (queue=3)
1.3.6.1.4.1.266.20.3.1.1.11Integer32 (0..7)read-writecurrent
portDefaultPrioQueue
OBJECT-TYPE
The default priority queue assigned all frames received on this port, for which no other priorisation applies (IEEE801.1q Tag or IPv4/IPv6). A value of 0 means the lowest priority level. A value of 3 means the highest priority level. To change this default queue use object portDot1qDefaultPrioValue.
1.3.6.1.4.1.266.20.3.1.1.12Integer32 (0..3)read-onlycurrent
portLEDGreen
OBJECT-TYPE
The function of the green port LED. Only supported for user ports
1.3.6.1.4.1.266.20.3.1.1.13INTEGER {notSupported(1), showLinkState(2), blink(3), allwaysOff(4), allwaysOn(5), showLinkSpeedDuplex(6)}read-writecurrent
portLEDYellow
OBJECT-TYPE
The function of the yellow port LED. Only supported for user ports
1.3.6.1.4.1.266.20.3.1.1.14INTEGER {notSupported(1), showDuplexState(2), blink(3), allwaysOff(4), allwaysOn(5), showPoeEnabled(6), showSpeed(7)}read-writecurrent
portBandwidthLimitRxd
OBJECT-TYPE
The bandwidth limiter for received packets. If set to disable(2) the limiter will be disabled.
1.3.6.1.4.1.266.20.3.1.1.15INTEGER {notSupported(1), disable(2), limit128k(3), limit256k(4), limit512k(5), limit1M(6), limit2M(7), limit4M(8), limit8M(9), limit16M(10), limit32M(11), limit64M(12), limit128M(13), limit256M(14)}read-writecurrent
portBandwidthLimitTxd
OBJECT-TYPE
The bandwidth limiter for transmitted packets. If set to disable(2) the limiter will be disabled.
1.3.6.1.4.1.266.20.3.1.1.16INTEGER {notSupported(1), disable(2), limit128k(3), limit256k(4), limit512k(5), limit1M(6), limit2M(7), limit4M(8), limit8M(9), limit16M(10), limit32M(11), limit64M(12), limit128M(13), limit256M(14)}read-writecurrent
portSecurityAdminState
OBJECT-TYPE
Enables the port security feature for that port. A value of notSupported(1) means, that port security ist not supported or disabled for that port (i.e. uplink port). The command renew(10) clears all learned MAC addresses and enables the port if it is disabled. See documentation for more details.
1.3.6.1.4.1.266.20.3.1.1.17INTEGER {notSupported(1), disable(2), manualSettingMacAddr(3), autoAllowOneMacAddr(4), autoAllowTwoMacAddr(5), autoAllowThreeMacAddr(6), radiusAllowOneMacAddr(7), radiusAllowTwoMacAddr(8), radiusAllowThreeMacAddr(9), renew(10), ieee802AllowOneMacAddr(11), vendorSettingMacAddr(12), ieee802AllowMultiMacAddr(13), ieee802OrRadiusOneMac(14), ieee802AndRadiusTwoMac(15), learnOneMacAddr(16), learnTwoMacAddr(17)}read-writecurrent
portSecurityMacAddr1
OBJECT-TYPE
The first MAC address used for port security. If portSecurityAdminState has the value disable(2), portSecurityManualSettingMacAddr(3) or vendorSettingMacAddr(12) then this object will be read-write. In any other mode this object will be read-only and shows the first automatically learned MAC addresses for that port.
1.3.6.1.4.1.266.20.3.1.1.18MacAddressread-writecurrent
portSecurityMacAddr2
OBJECT-TYPE
The second MAC address used for port security. If portSecurityAdminState has the value disable(2), portSecurityManualSettingMacAddr(3) or vendorSettingMacAddr(12) then this object will be read-write. In any other mode this object will be read-only and shows the second automatically learned MAC addresses for that port.
1.3.6.1.4.1.266.20.3.1.1.19MacAddressread-writecurrent
portSecurityMacAddr3
OBJECT-TYPE
The third MAC address used for port security. If portSecurityAdminState has the value disable(2), portSecurityManualSettingMacAddr(3) or vendorSettingMacAddr(12) then this object will be read-write. In any other mode this object will be read-only and shows the third automatically learned MAC addresses for that port.
1.3.6.1.4.1.266.20.3.1.1.20MacAddressread-writecurrent
portPoeAdminState
OBJECT-TYPE
If no POE adapter is installed this object is read-only and will always report notSupported(1). The possible values are: notSupported(1): No adapter installed or not supported for that port (i.e. uplink port). off(2): Adapter installed but inline power for that port is switched off. forcedOn(3): Adapter installed and inline power is asserted permanently. In the case of an IEEE802.3af adapter this setting will disable the IEEE802.3af automatic detection. autoOn(4): This setting is only supported if a IEEE802.3af adapter is installed. The adapter automatically detects if the connected device is IEEE802.3af compliant and will assert the power if possible. overloadFail(5): Adapter installed but inline power for that port is automatically switched off because of a overload condition at that port.
1.3.6.1.4.1.266.20.3.1.1.21INTEGER {notSupported(1), off(2), forcedOn(3), autoOn(4), overloadFail(5), reset(6), afHighPower(7), atHighPower(8)}read-writecurrent
portPoeVoltage
OBJECT-TYPE
The current PoE output voltage at this port in volts.
1.3.6.1.4.1.266.20.3.1.1.22Integer32read-onlycurrent
portPoeCurrent
OBJECT-TYPE
The current PoE output current at this port in milliampere.
1.3.6.1.4.1.266.20.3.1.1.23Integer32read-onlycurrent
portPoePower
OBJECT-TYPE
The current PoE output power at this port in milliwatt. The output power is the product of portPoeVoltage and portPoeCurrent.
1.3.6.1.4.1.266.20.3.1.1.24Integer32read-onlycurrent
portSecurityForwardingState
OBJECT-TYPE
The port security forwarding state of that port. See documentation for details.
1.3.6.1.4.1.266.20.3.1.1.25INTEGER {notSupported(1), portAdminDisabled(2), waitingForLink(3), unsecureVLAN(4), portAuthenticated(5), portSecurityDisabled(6), portLoopDisabled(7), authFailureVLAN(8), securityWarning(9), authenticatingClients(10), waitingForMacAddress(11), allRadiusServersDown(12), portBpduDisabled(13), portUdldDisabled(14), portLinkFlapDisabled(15), portErrorCountDisabled(16), portSfpErrorDisabled(17), portRedundanyLoopDisable(18)}read-onlycurrent
portPoePowerLimit
OBJECT-TYPE
The limit for the POE output power at this port in VA. If the current power exceeds this value a overload conditions occurs and the inline power for that port will be switched off.
1.3.6.1.4.1.266.20.3.1.1.26Integer32read-writecurrent
portLimiterPacketType
OBJECT-TYPE
The packet type for bandwidth limiter. If set to limitAllPacktes(2) then all packets are limited. If set to limitLoppBcastPackets(3) only flooted loop- and broadcast-pakets are limited.
1.3.6.1.4.1.266.20.3.1.1.27INTEGER {notSupported(1), limitAllPackets(2), limitLoopBcastPackets(3), limitAllPacketsBurstsAllowed(4)}read-writecurrent
portAcApSetup
OBJECT-TYPE
If portAcApSetup is enabled, the switch will perform Autocrossover and Autopolarity for this port. This function should only be enabled if portSpeedDuplexSetup ist set to autoneg.
1.3.6.1.4.1.266.20.3.1.1.28INTEGER {notSupported(1), allwaysEnable(2), enable(3), disable(4)}read-writecurrent
portLinkType
OBJECT-TYPE
The link type of that port. If set to upDownlink(3) the portAdminState will be forced to enable.
1.3.6.1.4.1.266.20.3.1.1.29INTEGER {user(1), userWithLoopProtection(2), upDownlink(3)}read-writecurrent
portVoiceVlanId
OBJECT-TYPE
The Voide-VLAN-ID assigned to this port. Packets of this Voice-VLAN are allway send with a VLAN-Tag, because IP-Phones normaly need a tagged VLAN. If portTrunkingMode is set to dot1qTagging, ALL frames are transmited with a VLAN-tag, except frames which belong to the Default-VLAN-ID. In this case the Voice-VLAN-ID has no effect. Changes of this value will take affect after the next switch reboot or after setting adminReset to renewIpAndVlanParameter(5). Setting this value to 0 will disable the Voice-VLAN.
1.3.6.1.4.1.266.20.3.1.1.30Integer32 (0..4095)read-writecurrent
portPrioDot1p
OBJECT-TYPE
Defines whether port prioritisation for IEEE802.1p packets is enabled.
1.3.6.1.4.1.266.20.3.1.1.31INTEGER {prioDot1pDisabled(1), prioDot1pEnabled(2)}read-writecurrent
portPrioIp
OBJECT-TYPE
Defines whether port prioritisation for IPv4/IPv6 packets is enabled.
1.3.6.1.4.1.266.20.3.1.1.32INTEGER {prioIpDisabled(1), prioIpEnabled(2)}read-writecurrent
bmSwitchVlan
OBJECT-IDENTITY
1.3.6.1.4.1.266.20.4
bmSwitchVlanTable
OBJECT-TYPE
A list of Virtual LAN instances.
1.3.6.1.4.1.266.20.4.1not-accessiblecurrent
bmSwitchVlanEntry
OBJECT-TYPE
VLAN entry.
1.3.6.1.4.1.266.20.4.1.1not-accessiblecurrent
vlanIndex
OBJECT-TYPE
A unique value for each VLAN entry. Its value ranges between 1 and 16.
1.3.6.1.4.1.266.20.4.1.1.1Integer32 (1..16)read-onlycurrent
vlanId
OBJECT-TYPE
The VLAN-ID assigned to this entry. Only entries with a VLAN-ID greater then 0 are valid entries. Setting a valid VLAN-ID to 0 will disable that entry and also delete the vlanDescr To add a new VLAN-ID first set an valid or non valid entry to the desired VLAN-ID. In a second step you may set the vlanDescr. Only VLAN-ID's listed in the vlanTable are forwarded by the switch.
1.3.6.1.4.1.266.20.4.1.1.2Integer32 (0..4095)read-writecurrent
vlanDescr
OBJECT-TYPE
A textual string containing information about the VLAN.
1.3.6.1.4.1.266.20.4.1.1.3DisplayString (SIZE(0..50))read-writecurrent
bmSwitchSfp
OBJECT-IDENTITY
1.3.6.1.4.1.266.20.5
bmSwitchSfpTable
OBJECT-TYPE
A list of SFP entries for the switch. The number of entries is defined by ifNumber.
1.3.6.1.4.1.266.20.5.1not-accessiblecurrent
bmSwitchSfpEntry
OBJECT-TYPE
A SFP entry in the table containing information about a SFP in the switch.
1.3.6.1.4.1.266.20.5.1.1not-accessiblecurrent
sfpPortIndex
OBJECT-TYPE
A unique value for each port. Its value ranges between 1 and the value of ifNumber. The port identified by a particular value of this index is the same port as identified by the same value of ifIndex.
1.3.6.1.4.1.266.20.5.1.1.1Integer32 (1..64)read-onlycurrent
sfpState
OBJECT-TYPE
A value indicating the current state of the SFP module. The possible values returned are: notSupported(1) The port has no SFP slot. noSfpInserted(2) The port has a SFP slot but there is no valid SFP module inserted. validSfpNoDiagnostic(3) A valid SFP module is inserted but the module doesn't supports diagnostic values. validSfpWithDiagnostic(4) A valid SFP module which supports diagnostic is inserted.
1.3.6.1.4.1.266.20.5.1.1.2INTEGER {notSupported(1), noSfpInserted(2), validSfpNoDiagnostic(3), validSfpWithDiagnostic(4)}read-onlycurrent
sfpInfoVendorName
OBJECT-TYPE
A textual string containing the vendor name of the SFP module.
1.3.6.1.4.1.266.20.5.1.1.3DisplayString (SIZE(0..17))read-onlycurrent
sfpInfoPartNumber
OBJECT-TYPE
A textual string containing the part number of the SFP module.
1.3.6.1.4.1.266.20.5.1.1.4DisplayString (SIZE(0..17))read-onlycurrent
sfpInfoRevisionNumber
OBJECT-TYPE
A textual string containing the revision number of the SFP module.
1.3.6.1.4.1.266.20.5.1.1.5DisplayString (SIZE(0..17))read-onlycurrent
sfpInfoSerialNumber
OBJECT-TYPE
A textual string containing the serial number of the SFP module.
1.3.6.1.4.1.266.20.5.1.1.6DisplayString (SIZE(0..17))read-onlycurrent
sfpInfoDateCode
OBJECT-TYPE
A textual string containing the date code of the SFP module.
1.3.6.1.4.1.266.20.5.1.1.7DisplayString (SIZE(0..17))read-onlycurrent
sfpInfoBitRate
OBJECT-TYPE
A textual string containing the bit rate of the SFP module. The unit is Mbit/s
1.3.6.1.4.1.266.20.5.1.1.8DisplayString (SIZE(0..17))read-onlycurrent
sfpInfoWavelength
OBJECT-TYPE
A textual string containing the wavelength of the SFP module. The unit is nm.
1.3.6.1.4.1.266.20.5.1.1.9DisplayString (SIZE(0..17))read-onlycurrent
sfpInfoLength9um
OBJECT-TYPE
A textual string containing the typically supported fiber length for 9um fiber cable. The unit is meters.
1.3.6.1.4.1.266.20.5.1.1.10DisplayString (SIZE(0..17))read-onlycurrent
sfpInfoLength50um
OBJECT-TYPE
A textual string containing the typically supported fiber length for 50um fiber cable. The unit is meters.
1.3.6.1.4.1.266.20.5.1.1.11DisplayString (SIZE(0..17))read-onlycurrent
sfpInfoLength62um
OBJECT-TYPE
A textual string containing the typically supported fiber length for 62.5um fiber cable. The unit is meters.
1.3.6.1.4.1.266.20.5.1.1.12DisplayString (SIZE(0..17))read-onlycurrent
sfpInfoConnectorDescr
OBJECT-TYPE
A textual string containing the connector description of the SFP module.
1.3.6.1.4.1.266.20.5.1.1.13DisplayString (SIZE(0..17))read-onlycurrent
sfpDiagTemperature
OBJECT-TYPE
The current temperature of the SFP module in degree celsius.
1.3.6.1.4.1.266.20.5.1.1.14Integer32read-onlycurrent
sfpDiagSupplyVoltage
OBJECT-TYPE
The current supply voltage of the SFP module in millivolt.
1.3.6.1.4.1.266.20.5.1.1.15Integer32read-onlycurrent
sfpDiagTxBiasCurrent
OBJECT-TYPE
The current transmitter bias current of the SFP module in milliampere.
1.3.6.1.4.1.266.20.5.1.1.16Integer32read-onlycurrent
sfpDiagTxOutputPower
OBJECT-TYPE
The current transmitter output power of the SFP module in microwatt.
1.3.6.1.4.1.266.20.5.1.1.17Integer32read-onlycurrent
sfpDiagTxOutputPowerDbm
OBJECT-TYPE
The current transmitter output power of the SFP module in dbm.
1.3.6.1.4.1.266.20.5.1.1.18Integer32read-onlycurrent
sfpDiagRxIntputPower
OBJECT-TYPE
The current receiver input power of the SFP module in microwatt.
1.3.6.1.4.1.266.20.5.1.1.19Integer32read-onlycurrent
sfpDiagRxInputPowerDbm
OBJECT-TYPE
The current receiver input power of the SFP module in dbm.
1.3.6.1.4.1.266.20.5.1.1.20Integer32read-onlycurrent
sfpAlarmTxBiasCurrentUpperLimit
OBJECT-TYPE
The maximum allowed transmitter bias current in milliampere. If the current value indicated by sfpDiagTxBiasCurrent exceeds sfpAlarmTxBiasCurrentUpperLimit, the switch sends an sfpEvent alarm trap. If the value of this limit is 0 no alarm will be send.
1.3.6.1.4.1.266.20.5.1.1.21Integer32read-writecurrent
sfpAlarmTxOutputPowerLowerLimit
OBJECT-TYPE
The minimum required transmitter output power in microwatt. If the power value indicated by sfpDiagTxOutputPower falls below sfpAlarmTxOutputPowerLowerLimit, the switch sends an sfpEvent alarm trap. If the value of this limit is 0 no alarm will be send.
1.3.6.1.4.1.266.20.5.1.1.22Integer32read-writecurrent
sfpAlarmRxInputPowerLowerLimit
OBJECT-TYPE
The minimum required received input power in microwatt. If the power value indicated by sfpDiagRxInputPower falls below sfpAlarmRxInputPowerLowerLimit, the switch sends an sfpEvent alarm trap. If the value of this limit is 0 no alarm will be send.
1.3.6.1.4.1.266.20.5.1.1.23Integer32read-writecurrent

Notifications

NameOIDStatus
switchTemperatureFailure
NOTIFICATION-TYPE
A TemperatureFailure signifies that the switch hardware has detected under- or overtemperature condition.
1.3.6.1.4.1.266.20.0.1current
portLinkChange
NOTIFICATION-TYPE
The trap is sent whenever the link state of a port changes from link-up to link-down or from link-down to link-up
1.3.6.1.4.1.266.20.0.2current
portNewMacAddress
NOTIFICATION-TYPE
A new source MAC address has been detected on a switch port. This trap is only send for ports which have port-security enabled with the setting autoAllowOneMacAddr, autoAllowTwoMacAddr or autoAllowThreeMacAddr.
1.3.6.1.4.1.266.20.0.3current
portSecurityFailure
NOTIFICATION-TYPE
An unauthorized source MAC address has accessed a port which has port-security enabled.
1.3.6.1.4.1.266.20.0.4current
portErrorCountFailure
NOTIFICATION-TYPE
The port error counter has incremented by 2 or more within a timewindow of two seconds. An counter increment by 1 ist not reported because single increments often may result because of link-changes.
1.3.6.1.4.1.266.20.0.5current
switchMgmtAuthFailure
NOTIFICATION-TYPE
A station has tried to access the switch management with a wrong authentication. This includes wrong user/password for telnet, wrong community for SNMP read/write and wrong accessrights in the accesslist.
1.3.6.1.4.1.266.20.0.6current
radiusMgmtAuthReject
NOTIFICATION-TYPE
A station has tried to access the switch management with radius authentication enabled and the radius server has rejected the request.
1.3.6.1.4.1.266.20.0.7current
radiusPortSecurityReject
NOTIFICATION-TYPE
A station has tried to access the switch with radius port security authentication enabled and the radius server has rejected the request.
1.3.6.1.4.1.266.20.0.8current
portLoopBcastFailure
NOTIFICATION-TYPE
The port broadcast/multicast counter has incremented by 25 packets/second for more then 10 successive seconds. Excessive multicast or broadcast packets may result in case of a loop between two port of the switch.
1.3.6.1.4.1.266.20.0.9current
switchPoeVoltageFailure
NOTIFICATION-TYPE
The switch has detected a PoE over- or undervoltage conditions.
1.3.6.1.4.1.266.20.0.10current
switchPoeOverloadFailure
NOTIFICATION-TYPE
The switch has detected a overload for the PoE power supply.
1.3.6.1.4.1.266.20.0.11current
portPoeOverloadFailure
NOTIFICATION-TYPE
The switch has detected a PoE overload condition at the port.
1.3.6.1.4.1.266.20.0.12current
portActiveLoopDetectionFailure
NOTIFICATION-TYPE
The active loop protection has disabled the port.
1.3.6.1.4.1.266.20.0.13current
switchIndustrialAlarmM1
NOTIFICATION-TYPE
The alarm state of the industrial alarm output M1 has changed.
1.3.6.1.4.1.266.20.0.14current
switchIndustrialAlarmM2
NOTIFICATION-TYPE
The alarm state of the industrial alarm output M2 has changed.
1.3.6.1.4.1.266.20.0.15current
switchInternalVoltageFailure
NOTIFICATION-TYPE
The switch has detected a internal over- or undervoltage conditions.
1.3.6.1.4.1.266.20.0.16current
tftpMessage
NOTIFICATION-TYPE
An successful or failed TFTP transfer has been occured. This does not include TFTP transfers executed from Nexan Manager.
1.3.6.1.4.1.266.20.0.17current
sfpEvent
NOTIFICATION-TYPE
The switch has detected one of the following SFP events: - a SFP module has been inserted - a SFP module has been removed - the optical receive power has fallen below the configured threshold - the optical transmit power has fallen below the configured threshold - the laser bias current has exceeded the configured threshold In the case of a threshold event, the trap will only send out every five minutes.
1.3.6.1.4.1.266.20.0.18current
clientRemoved
NOTIFICATION-TYPE
The client on this port has been removed because the link down time has exceeded the configured 'Link Down Timeout'.
1.3.6.1.4.1.266.20.0.19current
internalMgmtWarning
NOTIFICATION-TYPE
An internal management warning has been detected. Please consult Nexans for further informations regarding the reported warning code.
1.3.6.1.4.1.266.20.0.20current
switchFunctionInputAlarm
NOTIFICATION-TYPE
The state of the function input has changed.
1.3.6.1.4.1.266.20.0.21current
switchConfigurationChanged
NOTIFICATION-TYPE
The configuration of the switch has been changed.
1.3.6.1.4.1.266.20.0.22current
portErrorDisabled
NOTIFICATION-TYPE
The port has been error disabled.
1.3.6.1.4.1.266.20.0.23current