MIBs Depot

NETLINK-SPECIFIC-MIB

Registered at
1.3.6.1.2.1.41.1.2.1
1.3.6.1.4.1.173
Namespace
netlink
Source file
NETLINK-SPECIFIC-MIB
Digest
sha256:4614fcb779cfceb632824e8421ca96692b1706ef17c98cdbe4df9bbff2752262

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Gauge32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, enterprises, iso, mgmt, mib-2
SNMPv2-TCDisplayString, MacAddress, PhysAddress, RowStatus, TEXTUAL-CONVENTION, TimeInterval

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

NETLINK-SPECIFIC-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
NlSubscriberAddress
type

Objects

NameOIDSyntaxAccessStatus
snaDLC
OBJECT-IDENTITY
1.3.6.1.2.1.41
sdlc
OBJECT-IDENTITY
1.3.6.1.2.1.41.1
sdlcLSGroup
OBJECT-IDENTITY
1.3.6.1.2.1.41.1.2
sdlcLSAdminTable
OBJECT-IDENTITY
1.3.6.1.2.1.41.1.2.1
sdlcLSAdminEntry
OBJECT-IDENTITY
1.3.6.1.2.1.41.1.2.1.1
sdlcLSAddress
OBJECT-TYPE
This value is the poll address of the secondary link station for this SDLC link. It uniquely identifies the SDLC link station within a single SDLC port.
1.3.6.1.2.1.41.1.2.1.1.1INTEGER (1..255)read-onlymandatory
network
OBJECT-IDENTITY
1.3.6.1.4.1.173.6
netstat
OBJECT-IDENTITY
1.3.6.1.4.1.173.6.1
nsMaxNeigh
OBJECT-TYPE
Maximum number of neighbor nodes. This value is currently always 64 for FRX8000 and 20 for an N7400 or 7500. A neighbor is the closest node in a path from the local node.
1.3.6.1.4.1.173.6.1.1INTEGERread-onlymandatory
nsThisNode
OBJECT-TYPE
This nodes number. (1-250)
1.3.6.1.4.1.173.6.1.2INTEGERread-onlymandatory
nsNodTable
OBJECT-TYPE
A table showing all nodes known to this node along with status and neighbor information.
1.3.6.1.4.1.173.6.1.3not-accessiblemandatory
nsEntry
OBJECT-TYPE
Each entry of the node table is indexed by node number.
1.3.6.1.4.1.173.6.1.3.1not-accessiblemandatory
nsNodNum
OBJECT-TYPE
The node number of the desired node. This is the index into the node table.
1.3.6.1.4.1.173.6.1.3.1.1INTEGERread-onlymandatory
nsStatus
OBJECT-TYPE
The operational status of the node. The status is given as: 1 = Node is defined in the database; 9 = Node is operational;
1.3.6.1.4.1.173.6.1.3.1.2INTEGERread-onlymandatory
nsNumNeigh
OBJECT-TYPE
Current number of neighbor nodes to this node.
1.3.6.1.4.1.173.6.1.3.1.3INTEGERread-onlymandatory
nsNeighTable
OBJECT-TYPE
The neighbor table lists the status of a nodes neighbors.
1.3.6.1.4.1.173.6.1.4not-accessiblemandatory
nsNeighEntry
OBJECT-TYPE
The table entries are indexed by the node number and the neighbors node number.
1.3.6.1.4.1.173.6.1.4.1not-accessiblemandatory
nsNTNode
OBJECT-TYPE
The node number of the node whose neighbor's status is being sought.
1.3.6.1.4.1.173.6.1.4.1.1INTEGERread-onlymandatory
nsNTNeigh
OBJECT-TYPE
The node number of the neighbor whose status is being sought.
1.3.6.1.4.1.173.6.1.4.1.2INTEGERread-onlymandatory
nsNTNeighStat
OBJECT-TYPE
The status of the neighbor node given as: 1 = previously, but not currently, connected; 2 = Currently connected;
1.3.6.1.4.1.173.6.1.4.1.3INTEGER {notConnected(1), connected(2)}read-onlymandatory
local
OBJECT-IDENTITY
1.3.6.1.4.1.173.7
node
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.1
nodeCfgTable
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.1.1
nodeAlmTable
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.1.2
nodeSNMPGroup
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.1.3
nodeModel
OBJECT-TYPE
Describes the unit model
1.3.6.1.4.1.173.7.1.3.1INTEGER {model1(1), model2(2), rackmount(3), highavail(4), netfrad(5), frx4000(6), ss1800(7)}read-onlymandatory
nodeTrapText
OBJECT-TYPE
Text of the last alarm generated
1.3.6.1.4.1.173.7.1.3.2DisplayStringread-onlymandatory
nodeTrapAdrTable
OBJECT-TYPE
A table used to define the IP address of end-nodes to receive alarms generated by this node. Up to 16 addresses can be specified.
1.3.6.1.4.1.173.7.1.3.3not-accessiblemandatory
tpAdrEntry
OBJECT-TYPE
A Trap entry containing objects relating to SNMP traps.
1.3.6.1.4.1.173.7.1.3.3.1not-accessiblemandatory
tpAdrIdx
OBJECT-TYPE
The index into the trap configuration table
1.3.6.1.4.1.173.7.1.3.3.1.1INTEGERread-onlymandatory
tpAddress
OBJECT-TYPE
The IP Address of the end-station to send alarms
1.3.6.1.4.1.173.7.1.3.3.1.2IpAddressread-writemandatory
tpAdrFlag
OBJECT-TYPE
Defines the state of this entry as: 0 = Do not send traps to the Address; 1 = Send traps to the Address; 2 = This Address entry is deleted from the table;
1.3.6.1.4.1.173.7.1.3.3.1.3INTEGER {disableTraps(1), enableTraps(2), delete(3)}read-writemandatory
tpAdrSLev
OBJECT-TYPE
Lowest severity level traps that will be sent to this Address; 1 is the highest, 4 is the lowest.
1.3.6.1.4.1.173.7.1.3.3.1.4INTEGER {critical(1), major(2), minor(3), informational(4)}read-writemandatory
nodeBagTable
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.1.4
hwcard
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.2
rlpMaxProtos
OBJECT-TYPE
Maximum number of protocols allowed on each RLP. This value is currently 11 for FRX4000s, 9 for FRX6000s, and 5 for FRX7000s and FRX8000s.
1.3.6.1.4.1.173.7.2.1INTEGERread-onlymandatory
rlpConfigTable
OBJECT-TYPE
A Table to describe each RLP on the node
1.3.6.1.4.1.173.7.2.2not-accessiblemandatory
rlpEntry
OBJECT-TYPE
An RLP entry containing objects relating to RLPs.
1.3.6.1.4.1.173.7.2.2.1not-accessiblemandatory
rlpIndex
OBJECT-TYPE
The RLP number on the node
1.3.6.1.4.1.173.7.2.2.1.1INTEGERread-onlymandatory
rlpStatus
OBJECT-TYPE
The current state of this RLP
1.3.6.1.4.1.173.7.2.2.1.2INTEGER {installed(1), configured(2), load-failed(3), loading(4), ipl-failed(5), ipl-in-progress(6), failed(7), operational(8), power-off(9), power-on(10)}read-onlymandatory
rlpMemorySize
OBJECT-TYPE
The amount of memory installed on this RLP
1.3.6.1.4.1.173.7.2.2.1.3INTEGERread-onlymandatory
rlpLIC1Type
OBJECT-TYPE
The Type of Line Interface card in the first position
1.3.6.1.4.1.173.7.2.2.1.4INTEGER {none(1), rs232(2), rs422(3), v35(4), hs-rs232(5), x21(6), rs449(7), universal(8), t1(10), e1(11), voice(13)}read-onlymandatory
rlpLIC2Type
OBJECT-TYPE
The Type of Line Interface card in the second position
1.3.6.1.4.1.173.7.2.2.1.5INTEGER {none(1), rs232(2), rs422(3), v35(4), hs-rs232(5), x21(6), rs449(7), universal(8), t1(10), e1(11), voice(13)}read-onlymandatory
rlpProtocol
OBJECT-TYPE
The protocols configured on this RLP. This is an OCTET STRING where each octet represents a protocol type. The size of this is the maximum number of protocols allowed on an RLP (rlpMaxProtos). The protocol types are defined as: 00 = none 01 = X.25 02 = Frame Relay 03 = Async 04 = SDLC 05 = BSC Interactive 07 = IP 08 = SNMP 09 = RIP 0A = LLC2 0B = Trunk 0C = IPX 0D = Config 0E = LLC2-R 0F = IP-R 10 = NVSP 11 = Bridge
1.3.6.1.4.1.173.7.2.2.1.6OCTET STRINGread-writemandatory
rlpGroupNumber
OBJECT-TYPE
The group to which this RLP belongs- always 1 if not FRX7000.
1.3.6.1.4.1.173.7.2.2.1.7INTEGER (1..4)read-onlymandatory
rlpGroupResponsibility
OBJECT-TYPE
The responsibility of this RLP within its group, always primary if not FRX7000.
1.3.6.1.4.1.173.7.2.2.1.8INTEGER {primary(1), secondary(2)}read-onlymandatory
port
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.3
portX25Group
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.3.1
portPhyX25AdminTable
OBJECT-TYPE
This table contains Netlink Enterprise specific objects to manage an X25 port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation. Most of the objects in this read-write table have corresponding read-only objects in the portX25OperTable that return the current operating value. The operating values may be different from these configured values if a configured parameter was configured after the interface was started.
1.3.6.1.4.1.173.7.3.1.1not-accessiblemandatory
portPhyX25AdminEntry
OBJECT-TYPE
A list of configured values for an X25 port.
1.3.6.1.4.1.173.7.3.1.1.1not-accessiblemandatory
portPhyX25AdminConnector
OBJECT-TYPE
Physical port interface connector type.
1.3.6.1.4.1.173.7.3.1.1.1.1INTEGER {rs232(3), v35(5), rs449(6), rs530(7), x21(8), t1(10), e1(11)}read-writemandatory
portPhyX25AdminSpeed
OBJECT-TYPE
This object defines the speed of the X25 port. The speed may only be set to one of a series of reasonable values, and if an attempt is made to set the speed to a value which is within the valid range but not equal to one of these values, the speed will be rounded up. If the connector type of the port is RS232, the port could be a standard port or a high speed port. If the port is a high speed RS232 port, the maximum valid speed is 256000. If the port is a standard RS232 port, the maximum valid speed is 64000 on the FRX4000/SS1840 and 19200 on all other products. It may be possible to set the speed of a standard RS232 port to a speed which is valid for a high speed RS232 port but invalid for a standard RS232 port. In this case, the port may not end up having the invalid speed. The default speed for a standard RS232 port on the FRX6000 is 19200.
1.3.6.1.4.1.173.7.3.1.1.1.2INTEGERread-writemandatory
portPhyX25AdminGenerateClock
OBJECT-TYPE
Specifies whether the port will generate the clock necessary to synchronize traffic over the link.
1.3.6.1.4.1.173.7.3.1.1.1.3INTEGER {no(1), yes(2)}read-writemandatory
portPhyX25AdminRcvClockFromDTE
OBJECT-TYPE
This object defines whether the receive clock will be used from the DTE.
1.3.6.1.4.1.173.7.3.1.1.1.4INTEGER {no(1), yes(2)}read-writemandatory
portPhyX25AdminDialOut
OBJECT-TYPE
This flag indicates whether the port is connected to a dial modem, and whethter connections will be initiated through dial-in or dial-out calls.
1.3.6.1.4.1.173.7.3.1.1.1.5INTEGER {none(1), dialIn(2), dialOut(3)}read-writemandatory
portPhyX25AdminInactivityTimer
OBJECT-TYPE
This timer defines in minutes, the period of inactivity allowed between calls. Once the timer expires, the port is disabled untill the next call is placed, if a Dial out port, or the Disconnect Timer expires, if a Dial in port. This variable is only meaningful if the port is a Dial port.
1.3.6.1.4.1.173.7.3.1.1.1.6INTEGER (1..30)read-writemandatory
portPhyX25AdminDisconnectTimer
OBJECT-TYPE
This timer defines, in seconds, the length of time a dial-in port will remain disabled after expiration of the InActivity Timer.
1.3.6.1.4.1.173.7.3.1.1.1.7INTEGER (1..255)read-writemandatory
portPhyX25AdminSetupTimer
OBJECT-TYPE
This timer determines the length of time, in seconds, that a response must be received by the port, after entering the Linkup state. If a response is not received, the port enters a Failed state.
1.3.6.1.4.1.173.7.3.1.1.1.8INTEGER (1..255)read-writemandatory
portPhyX25AdminTrunkFlag
OBJECT-TYPE
This flag, when set, indicates the port is associated with a network trunk group. It will be disabled/enabled if the network trunk is not operational.
1.3.6.1.4.1.173.7.3.1.1.1.9INTEGER {no(1), yes(2)}read-writemandatory
portPhyX25AdminTrunkGroup
OBJECT-TYPE
This variable contains a string of 8 bytes, with each byte indicating 8 ports on an RLP that may be a part of a trunk group. Since a TurboFrad has only 1 RLP, only the first byte is valid if the node is an FRX4000. Each port is represented by a single bit within the RLP byte. The bit position represents the port number...for example, if port 2 on RLP 0 was in a trunk group, the first byte of the string would contain x04 and all other bytes would be 0.
1.3.6.1.4.1.173.7.3.1.1.1.10OCTET STRINGread-writemandatory
portPhyX25AdminRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the portPhyX25AdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device, and which is supplied by a management station wishing to exercise an on-line update of the existing conceptual row. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.3.1.1.1.11RowStatusread-writemandatory
portPhyX25OperTable
OBJECT-TYPE
This table contains Netlink Enterprise specific objects to manage an X25 port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation. All of the objects in this table are read-only. The operating values may be different from these configured values if a configured parameter was configured after the interface was started.
1.3.6.1.4.1.173.7.3.1.2not-accessiblemandatory
portPhyX25OperEntry
OBJECT-TYPE
A list of configured values for an X25 port.
1.3.6.1.4.1.173.7.3.1.2.1not-accessiblemandatory
portPhyX25OperConnector
OBJECT-TYPE
Physical port interface connector type.
1.3.6.1.4.1.173.7.3.1.2.1.1INTEGER {rs232(3), v35(5), rs449(6), rs530(7), x21(8), t1(10), e1(11)}read-onlymandatory
portPhyX25OperSpeed
OBJECT-TYPE
This object defines the speed of the X25 port. The speed may only be set to one of a series of reasonable values, and if an attempt is made to set the speed to a value which is within the valid range but not equal to one of these values, the speed will be rounded up. If the connector type of the port is RS232, the port could be a standard port or a high speed port. If the port is a high speed RS232 port, the maximum valid speed is 256000. If the port is a standard RS232 port, the maximum valid speed is 64000 on the FRX4000/SS1840 and 19200 on all other products. It may be possible to set the speed of a standard RS232 port to a speed which is valid for a high speed RS232 port but invalid for a standard RS232 port. In this case, the port may not end up having the invalid speed. The default speed for a standard RS232 port on the FRX6000 is 19200.
1.3.6.1.4.1.173.7.3.1.2.1.2INTEGERread-onlymandatory
portPhyX25OperGenerateClock
OBJECT-TYPE
Specifies whether the port will generate the clock necessary to synchronize traffic over the link.
1.3.6.1.4.1.173.7.3.1.2.1.3INTEGER {no(1), yes(2)}read-onlymandatory
portPhyX25OperRcvClockFromDTE
OBJECT-TYPE
This object defines whether the receive clock will be used from the DTE.
1.3.6.1.4.1.173.7.3.1.2.1.4INTEGER {no(1), yes(2)}read-onlymandatory
portPhyX25OperDialOut
OBJECT-TYPE
This flag indicates whether the port is connected to a dial modem, and whethter connections will be initiated through dial-in or dial-out calls.
1.3.6.1.4.1.173.7.3.1.2.1.5INTEGER {none(1), dialIn(2), dialOut(3)}read-onlymandatory
portPhyX25OperInactivityTimer
OBJECT-TYPE
This timer defines in minutes, the period of inactivity allowed between calls. Once the timer expires, the port is disabled untill the next call is placed, if a Dial out port, or the Disconnect Timer expires, if a Dial in port. This variable is only meaningful if the port is a Dial port.
1.3.6.1.4.1.173.7.3.1.2.1.6INTEGER (1..30)read-onlymandatory
portPhyX25OperDisconnectTimer
OBJECT-TYPE
This timer defines, in seconds, the length of time a dial-in port will remain disabled after expiration of the InActivity Timer.
1.3.6.1.4.1.173.7.3.1.2.1.7INTEGER (1..255)read-onlymandatory
portPhyX25OperSetupTimer
OBJECT-TYPE
This timer determines the length of time, in seconds, that a response must be received by the port, after entering the Linkup state. If a response is not received, the port enters a Failed state.
1.3.6.1.4.1.173.7.3.1.2.1.8INTEGER (1..255)read-onlymandatory
portPhyX25OperTrunkFlag
OBJECT-TYPE
This flag, when set, indicates the port is associated with a network trunk group. It will be disabled/enabled if the network trunk is not operational.
1.3.6.1.4.1.173.7.3.1.2.1.9INTEGER {no(1), yes(2)}read-onlymandatory
portPhyX25OperTrunkGroup
OBJECT-TYPE
This variable contains a string of 8 bytes, with each byte indicating a port on this RLP that may be a part of a trunk group.
1.3.6.1.4.1.173.7.3.1.2.1.10OCTET STRINGread-onlymandatory
portLogicalX25AdminTable
OBJECT-TYPE
This table contains Netlink Enterprise specific objects to manage an X25 Logical port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation. The operating values may be different from these configured values if a configured parameter was configured after the interface was started.
1.3.6.1.4.1.173.7.3.1.3not-accessiblemandatory
portLogicalX25AdminEntry
OBJECT-TYPE
A list of configured values for an X25 logical port.
1.3.6.1.4.1.173.7.3.1.3.1not-accessiblemandatory
portLogicalX25AdminFrDlci
OBJECT-TYPE
The DLCI number used to identify the entry in the table. The range is 16-991.
1.3.6.1.4.1.173.7.3.1.3.1.1INTEGER (16..991)read-writemandatory
portLogicalX25AdminCxnPriority
OBJECT-TYPE
This field sets the priority of the connection among others on the physical port. The range is 0 for lowest priority to 9 for the highest priority.
1.3.6.1.4.1.173.7.3.1.3.1.2INTEGER (0..9)read-writemandatory
portLogicalX25AdminRfc1490
OBJECT-TYPE
This field indicates the encapsulation method used
1.3.6.1.4.1.173.7.3.1.3.1.3INTEGER {annexG(1), rfc1490(2)}read-writemandatory
portLogicalX25AdminBAG
OBJECT-TYPE
Assigns this DLCI to one of sixteen groups whose parameters regulate bandwidth usage. A 0 value indicates the DLCI does not use BAGs
1.3.6.1.4.1.173.7.3.1.3.1.4INTEGER (0..16)read-writemandatory
portLogicalX25AdminRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the portLogicalX25AdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device, and which is supplied by a management station wishing to exercise an on-line update of the existing conceptual row. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.3.1.3.1.5RowStatusread-writemandatory
portLogicalX25OperTable
OBJECT-TYPE
This table contains Netlink Enterprise specific objects to manage an X25 Logical port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation. The operating values may be different from these configured values if a configured parameter was configured after the interface was started.
1.3.6.1.4.1.173.7.3.1.4not-accessiblemandatory
portLogicalX25OperEntry
OBJECT-TYPE
A list of configured values for an X25 port.
1.3.6.1.4.1.173.7.3.1.4.1not-accessiblemandatory
portLogicalX25OperFrDlci
OBJECT-TYPE
The DLCI number used to identify the entry in the table. The range is 16-991.
1.3.6.1.4.1.173.7.3.1.4.1.1INTEGER (1..255)read-onlymandatory
portLogicalX25OperCxnPriority
OBJECT-TYPE
This field sets the priority of the connection among others on the physical port. The range is 0 for lowest priority to 9 for the highest priority.
1.3.6.1.4.1.173.7.3.1.4.1.2INTEGER (0..9)read-onlymandatory
portLogicalX25OperRfc1490
OBJECT-TYPE
This field indicates the encapsulation method used
1.3.6.1.4.1.173.7.3.1.4.1.3INTEGER {annexG(1), rfc1490(2)}read-onlymandatory
portLogicalX25OperBAG
OBJECT-TYPE
Assigns this DLCI to one of sixteen groups whose parameters regulate bandwidth usage.
1.3.6.1.4.1.173.7.3.1.4.1.4INTEGER (1..16)read-onlymandatory
portX25AdminTable
OBJECT-TYPE
This table contains Netlink Enterprise specific objects to manage an X25 port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation. Most of the objects in this read-write table have corresponding read-only objects in the portX25OperTable that return the current operating value. The operating values may be different from these configured values if a configured parameter was configured after the interface was started.
1.3.6.1.4.1.173.7.3.1.5not-accessiblemandatory
portX25AdminEntry
OBJECT-TYPE
A list of configured values for an X25 port.
1.3.6.1.4.1.173.7.3.1.5.1not-accessiblemandatory
portX25AdminBlockedFlag
OBJECT-TYPE
A flag which when set, means the port should not be enabled after a boot-up of the node.
1.3.6.1.4.1.173.7.3.1.5.1.1INTEGER {no(1), yes(2)}read-writemandatory
portX25AdminFlowCtrlNeg
OBJECT-TYPE
A flag which if set, permits negotiation of the flow control parameters on a per call basis. If N is selected, the default packet and window sizes will be used. If Y is selected, the packet or window size in a call packet (up to the configured Max Packet Size or Max Window Size) is used.
1.3.6.1.4.1.173.7.3.1.5.1.2INTEGER {no(1), yes(2)}read-writemandatory
portX25AdminThruptClassNeg
OBJECT-TYPE
A flag which ,if set, permists negotiation of the throughput class for either direction of data transmission on a per call basis. If N is selected, the configured Max Throughput Class value is used. If Y, any throughput class in a call packet (up to the Max Thruput Class) is used.
1.3.6.1.4.1.173.7.3.1.5.1.3INTEGER {no(1), yes(2)}read-writemandatory
portX25AdminLocChgPrev
OBJECT-TYPE
If Y is selected, no calls can be charged to port. Incoming calls from the network with reverse charge specified will be rejected. Outgoing calls will insert reverse charge in the call packet if not already included.
1.3.6.1.4.1.173.7.3.1.5.1.4INTEGER {no(1), yes(2)}read-writemandatory
portX25AdminRevChgAccpt
OBJECT-TYPE
A flag, if set, that authorizes transmission of incoming calls that request the reverse charge facility. If N is selected, and a call requests it, it will not be transmitted.
1.3.6.1.4.1.173.7.3.1.5.1.5INTEGER {no(1), yes(2)}read-writemandatory
portX25AdminFastSelAccpt
OBJECT-TYPE
A flag, if set, that authorizes transmission of incoming calls that request the Fast Select facility.
1.3.6.1.4.1.173.7.3.1.5.1.6INTEGER {no(1), yes(2)}read-writemandatory
portX25AdminInCallBar
OBJECT-TYPE
An X25 facility that prevents transmission of incoming calls to the local DTE.
1.3.6.1.4.1.173.7.3.1.5.1.7INTEGER {no(1), yes(2)}read-writemandatory
portX25AdminOutCallBar
OBJECT-TYPE
An X25 facility that prevents transmission of incoming calls to the local DTE.
1.3.6.1.4.1.173.7.3.1.5.1.8INTEGER {no(1), yes(2)}read-writemandatory
portX25AdminMaxPktSize
OBJECT-TYPE
The maximum data packet size that will be allowed to pass through this port.
1.3.6.1.4.1.173.7.3.1.5.1.9INTEGER (128..4096)read-writemandatory
portX25AdminDefPktSize
OBJECT-TYPE
This is the size that will be assigned to an incoming call setup packet if the packet does not request a packet size.
1.3.6.1.4.1.173.7.3.1.5.1.10INTEGER (16..4096)read-writemandatory
portX25AdminMaxWinSize
OBJECT-TYPE
This is the maximum number of unacknowledged packets per logical channel that can pass through this port.
1.3.6.1.4.1.173.7.3.1.5.1.11INTEGER (2..7)read-writemandatory
portX25AdminDefWinSize
OBJECT-TYPE
This size will be assigned to an incoming call setup packet if the packet doesn't request a window size.
1.3.6.1.4.1.173.7.3.1.5.1.12INTEGER (1..7)read-writemandatory
portX25AdminMaxThruptClass
OBJECT-TYPE
This specifies the default throughput class that will be inserted into a Call Request packet if Thruput Class negotiation is not enabled or if a thruput class is not requested in the call request.
1.3.6.1.4.1.173.7.3.1.5.1.13INTEGER (3..13)read-writemandatory
portX25AdminCUGPref
OBJECT-TYPE
This flag, if set, indicates the port belongs to at least one CUG.
1.3.6.1.4.1.173.7.3.1.5.1.14INTEGER {no(1), yes(2)}read-writemandatory
portX25AdminCUGIndex
OBJECT-TYPE
This number is an index into a Closed User Group table which identifies the default Closed User Group for the port.
1.3.6.1.4.1.173.7.3.1.5.1.15INTEGER (1..100)read-writemandatory
portX25AdminCUGIncAccess
OBJECT-TYPE
This flag, when set, indicates whether this port will be allowed to receive calls from outside its CUGs.
1.3.6.1.4.1.173.7.3.1.5.1.16INTEGER {no(1), yes(2)}read-writemandatory
portX25AdminCUGOutAccess
OBJECT-TYPE
This flag, when set, indicates whether this port will be allowed to make calls outside its CUGs.
1.3.6.1.4.1.173.7.3.1.5.1.17INTEGER {no(1), yes(2)}read-writemandatory
portX25OperTable
OBJECT-TYPE
This table contains Netlink Enterprise specific objects to manage an X25 port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation. The objects in this read-only table corresponding read-only objects in the portX25OperTable that return the current operating value. The operating values may be different from these configured values if a configured parameter was configured after the interface was started.
1.3.6.1.4.1.173.7.3.1.6not-accessiblemandatory
portX25OperEntry
OBJECT-TYPE
A list of configured values for an X25 port.
1.3.6.1.4.1.173.7.3.1.6.1not-accessiblemandatory
portX25OperBlockedFlag
OBJECT-TYPE
A flag which when set, means the port should not be enabled after a boot-up of the node.
1.3.6.1.4.1.173.7.3.1.6.1.1INTEGER {no(1), yes(2)}read-onlymandatory
portX25OperFlowCtrlNeg
OBJECT-TYPE
A flag which if set, permits negotiation of the flow control parameters on a per call basis. If N is selected, the default packet and window sizes will be used. If Y is selected, the packet or window size in a call packet (up to the configured Max Packet Size or Max Window Size) is used.
1.3.6.1.4.1.173.7.3.1.6.1.2INTEGER {no(1), yes(2)}read-onlymandatory
portX25OperThruptClassNeg
OBJECT-TYPE
A flag which ,if set, permists negotiation of the throughput class for either direction of data transmission on a per call basis. If N is selected, the configured Max Throughput Class value is used. If Y, any throughput class in a call packet (up to the Max Thruput Class) is used.
1.3.6.1.4.1.173.7.3.1.6.1.3INTEGER {no(1), yes(2)}read-onlymandatory
portX25OperLocChgPrev
OBJECT-TYPE
If Y is selected, no calls can be charged to port. Incoming calls from the network with reverse charge specified will be rejected. Outgoing calls will insert reverse charge in the call packet if not already included.
1.3.6.1.4.1.173.7.3.1.6.1.4INTEGER {no(1), yes(2)}read-onlymandatory
portX25OperRevChgAccpt
OBJECT-TYPE
A flag, if set, that authorizes transmission of incoming calls that request the reverse charge facility. If N is selected, and a call requests it, it will not be transmitted.
1.3.6.1.4.1.173.7.3.1.6.1.5INTEGER {no(1), yes(2)}read-onlymandatory
portX25OperFastSelAccpt
OBJECT-TYPE
A flag, if set, that authorizes transmission of incoming calls that request the Fast Select facility.
1.3.6.1.4.1.173.7.3.1.6.1.6INTEGER {no(1), yes(2)}read-onlymandatory
portX25OperInCallBar
OBJECT-TYPE
An X25 facility that prevents transmission of incoming calls to the local DTE.
1.3.6.1.4.1.173.7.3.1.6.1.7INTEGER {no(1), yes(2)}read-onlymandatory
portX25OperOutCallBar
OBJECT-TYPE
An X25 facility that prevents transmission of incoming calls to the local DTE.
1.3.6.1.4.1.173.7.3.1.6.1.8INTEGER {no(1), yes(2)}read-onlymandatory
portX25OperMaxPktSize
OBJECT-TYPE
The maximum data packet size that will be allowed to pass through this port.
1.3.6.1.4.1.173.7.3.1.6.1.9INTEGER (128..4096)read-onlymandatory
portX25OperDefPktSize
OBJECT-TYPE
This is the size that will be assigned to an incoming call setup packet if the packet does not request a packet size.
1.3.6.1.4.1.173.7.3.1.6.1.10INTEGER (16..4096)read-onlymandatory
portX25OperMaxWinSize
OBJECT-TYPE
This is the maximum number of unacknowledged packets per logical channel that can pass through this port.
1.3.6.1.4.1.173.7.3.1.6.1.11INTEGER (2..7)read-onlymandatory
portX25OperDefWinSize
OBJECT-TYPE
This size will be assigned to an incoming call setup packet if the packet doesn't request a window size.
1.3.6.1.4.1.173.7.3.1.6.1.12INTEGER (1..7)read-onlymandatory
portX25OperMaxThruptClass
OBJECT-TYPE
This specifies the default throughput class that will be inserted into a Call Request packet if Thruput Class negotiation is not enabled or if a thruput class is not requested in the call request.
1.3.6.1.4.1.173.7.3.1.6.1.13INTEGER (3..13)read-onlymandatory
portX25OperCUGPref
OBJECT-TYPE
This flag, if set, indicates the port belongs to at least one CUG.
1.3.6.1.4.1.173.7.3.1.6.1.14INTEGER {no(1), yes(2)}read-onlymandatory
portX25OperCUGIndex
OBJECT-TYPE
This number is an index into a Closed User Group table which identifies the default Closed User Group for the port.
1.3.6.1.4.1.173.7.3.1.6.1.15INTEGER (1..100)read-onlymandatory
portX25OperCUGIncAccess
OBJECT-TYPE
This flag, when set, indicates whether this port will be able to receive calls from outside its CUGs.
1.3.6.1.4.1.173.7.3.1.6.1.16INTEGER {no(1), yes(2)}read-onlymandatory
portX25OperCUGOutAccess
OBJECT-TYPE
This flag, when set, indicates whether this port will be able to make calls outside its CUGs.
1.3.6.1.4.1.173.7.3.1.6.1.17INTEGER {no(1), yes(2)}read-onlymandatory
portFrGroup
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.3.2
portFrConfigTable
OBJECT-TYPE
A list of Frame Relay ports . The number of entries will be the number of Frame Relay ports on the node.
1.3.6.1.4.1.173.7.3.2.1not-accessiblemandatory
portFrEntry
OBJECT-TYPE
An Frame Relay Port entry containing objects relating to the port that are configurable by the user.
1.3.6.1.4.1.173.7.3.2.1.1not-accessiblemandatory
portFrRlpIndex
OBJECT-TYPE
The RLP number of the Frame Relay port. It will be in the range 1-8.
1.3.6.1.4.1.173.7.3.2.1.1.1INTEGERread-onlymandatory
portFrPortIndex
OBJECT-TYPE
The Port number of the Frame Relay port. It will be in the range 1-8 for a physical port. It will be in the range 9-64 for a Frame Relay logical port.
1.3.6.1.4.1.173.7.3.2.1.1.2INTEGERread-onlymandatory
portFrBlockedFlag
OBJECT-TYPE
A flag which when set, means the port should not be enabled after a boot-up of the node.
1.3.6.1.4.1.173.7.3.2.1.1.3INTEGER {no(1), yes(2)}read-writemandatory
portFrMaxBytesPerFrame
OBJECT-TYPE
The maximum number of bytes allowed in an I Frame for this Frame Relay port.
1.3.6.1.4.1.173.7.3.2.1.1.4INTEGER (16..4096)read-writemandatory
portFrT392Timer
OBJECT-TYPE
This timer indicates how long the network will wait between Status Enquiry messages before recording an error. It should be greater than or equal to the frDlcmiPollingInterval variable in the RFC1315 Mib.
1.3.6.1.4.1.173.7.3.2.1.1.5INTEGER (5..30)read-writemandatory
portFrOutgoingRateControl
OBJECT-TYPE
This is a flag which, when set, enables the enforcement of the Outgoing Rate Control parameters.
1.3.6.1.4.1.173.7.3.2.1.1.6INTEGER {no(1), yes(2)}read-writemandatory
portFrBandwidthAllocation
OBJECT-TYPE
This is a flag which, when set, enables whether the bandwidth allocation will be enforced.
1.3.6.1.4.1.173.7.3.2.1.1.7INTEGER {no(1), yes(2)}read-writemandatory
portFrConnector
OBJECT-TYPE
This defines the connector type of the Frame Relay port.
1.3.6.1.4.1.173.7.3.2.1.1.8INTEGER {rs232(3), v35(5), rs449(6), rs530(7), x21(8), t1(10), e1(11)}read-writemandatory
portFrLogicalDCE
OBJECT-TYPE
This defines the port as logical DCE or DTE.
1.3.6.1.4.1.173.7.3.2.1.1.9INTEGER {no(1), yes(2)}read-writemandatory
portFrGenClock
OBJECT-TYPE
This specifies whether the port will generate the clock necessary to synchronize traffic over the link.
1.3.6.1.4.1.173.7.3.2.1.1.10INTEGER {no(1), yes(2)}read-writemandatory
portFrRcvClkFrmDTE
OBJECT-TYPE
This allows the clock to be looped back from the DTE using the TT (Terminal Timing) signal, which can be helpful on high-speed lines.
1.3.6.1.4.1.173.7.3.2.1.1.11INTEGER {no(1), yes(2)}read-writemandatory
portFrLLM
OBJECT-TYPE
This determines whether, and what type of, configurable network management (status enquiries) will be allowed.
1.3.6.1.4.1.173.7.3.2.1.1.12INTEGER {none(1), lmi(2), annexd(3)}read-writemandatory
portFrRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the portFrConfigTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device, and which is supplied by a management station wishing to exercise an on-line update of the existing conceptual row. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.3.2.1.1.13RowStatusread-writemandatory
portFrSpeed
OBJECT-TYPE
This object defines the speed of the Frame Relay port. The speed may only be set to one of a series of reasonable values, and if an attempt is made to set the speed to a value which is within the valid range but not equal to one of these values, the speed will be rounded up. If the connector type of the port is RS232, the port could be a standard port or a high speed port. If the port is a high speed RS232 port, the maximum valid speed is 256000. If the port is a standard RS232 port, the maximum valid speed is 64000 on the FRX4000/SS1840 and 19200 on all other products. It may be possible to set the speed of a standard RS232 port to a speed which is valid for a high speed RS232 port but invalid for a standard RS232 port. In this case, the port may not end up having the invalid speed. The default speed for a standard RS232 port on the FRX6000 is 19200.
1.3.6.1.4.1.173.7.3.2.1.1.14INTEGER (75..2048000)read-writemandatory
portFrBackupUseOnly
OBJECT-TYPE
This object determines whether all DLCIs on the port will be reserved exclusively as backups for other DLCIs in the same node. If yes is specified for this object, the port will remain disabled until needed for backup.
1.3.6.1.4.1.173.7.3.2.1.1.15INTEGER {no(1), yes(2)}read-writemandatory
portDLCIConfigTable
OBJECT-TYPE
A list of DLCI's on Frame Relay ports . The number of entries will be the number of DLCIs on all the Frame Relay ports on a node.
1.3.6.1.4.1.173.7.3.2.2not-accessiblemandatory
portDLCIEntry
OBJECT-TYPE
An Frame Relay Port DLCI entry relating to the Rate Control Information that is configurable by the user.
1.3.6.1.4.1.173.7.3.2.2.1not-accessiblemandatory
portDLCIRlpIndex
OBJECT-TYPE
The RLP number on which the DLCI is located. The range for this is 1-8.
1.3.6.1.4.1.173.7.3.2.2.1.1INTEGERread-onlymandatory
portDLCIPortIndex
OBJECT-TYPE
The port number on which the DLCI is located. The range for this is 1-8 for a physical FR port and 9-64 for a logical FR port.
1.3.6.1.4.1.173.7.3.2.2.1.2INTEGERread-onlymandatory
portDLCIIndex
OBJECT-TYPE
The DLCI number used to identify the entry in the table. The range is 16-991.
1.3.6.1.4.1.173.7.3.2.2.1.3INTEGERread-onlymandatory
portDLCIIncomingCIR
OBJECT-TYPE
The committed information rate that is supported on the DLCI for incoming data.
1.3.6.1.4.1.173.7.3.2.2.1.4INTEGER (0..2000)read-writemandatory
portDLCIOutgoingCIR
OBJECT-TYPE
The committed information rate that is supported on the DLCI for outgoing data.
1.3.6.1.4.1.173.7.3.2.2.1.5INTEGER (0..2000)read-writemandatory
portDLCIIncomingBc
OBJECT-TYPE
The committed burst size is the maximum amount of data to be transmitted under normal conditions within the time period defined by Bc/Cir that is supported on the DLCI for incoming data.
1.3.6.1.4.1.173.7.3.2.2.1.6INTEGERread-writemandatory
portDLCIOutgoingBc
OBJECT-TYPE
The committed burst size is the maximum amount of data to be transmitted under normal conditions within the time period defined by Bc/Cir that is supported on the DLCI for Outgoing data.
1.3.6.1.4.1.173.7.3.2.2.1.7INTEGERread-writemandatory
portDLCIIncomingBe
OBJECT-TYPE
The excess burst size is the maximum amount of incoming data in excess of the committed burst size that the network will try to transfer during the time interval determined by Bc/Cir on this DLCI.
1.3.6.1.4.1.173.7.3.2.2.1.8INTEGER (0..32767)read-writemandatory
portDLCIOutgoingBe
OBJECT-TYPE
The excess burst size is the maximum amount of incoming data in excess of the committed burst size that the network will try to transfer during the time interval determined by Bc/Cir on this DLCI.
1.3.6.1.4.1.173.7.3.2.2.1.9INTEGER (0..32767)read-writemandatory
portDLCIBecnRecoveryCnt
OBJECT-TYPE
The BECN recovery Count is a method of controlling the rate of return to max traffic flow after it has been reduced due to congestion. The value determines the number of packets received sequentially without BECN set, before increasing the Excess Burst Size by 1/8 of it's configured value.
1.3.6.1.4.1.173.7.3.2.2.1.10INTEGER (0..255)read-writemandatory
portDLCIPriority
OBJECT-TYPE
This field sets the priority of the DLCI among others on the physical port. The range is 0 for lowest priority to 4 for the highest priority.
1.3.6.1.4.1.173.7.3.2.2.1.11INTEGER (0..4)read-writemandatory
portDLCIRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the portDLCIConfigTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. Also note that deleting a DLCI entry will only remove it from the database file, and it's existence will still be known by the protocol until the node is rebooted.
1.3.6.1.4.1.173.7.3.2.2.1.12RowStatusread-writemandatory
portDLCIBackupGroup
OBJECT-TYPE
This object specifies (if configured as any number other than zero) that this is a primary DLCI, and identifies the backup DLCI(s) (in a Frame Relay backup group) that will take over if this DLCI fails. This is applicable only on an initiating node, which is the node that will initiate the switchover to a backup DLCI. At switchover, the initiating node notifies the remote node of the change.
1.3.6.1.4.1.173.7.3.2.2.1.13INTEGERread-writemandatory
portDLCIBackupProtEnb
OBJECT-TYPE
This object specifies whether the DLCI will be used as a non-initiating backup DLCI. The DLCI will wait for a backup protocol message from the initiating end, telling the backup where to send the rest of the messages.
1.3.6.1.4.1.173.7.3.2.2.1.14INTEGER {no(1), yes(2)}read-writemandatory
portFrBackupGroupTable
OBJECT-TYPE
A Table describes the Frame Relay Backup MIB .
1.3.6.1.4.1.173.7.3.2.3not-accessiblemandatory
portFrBackupEntry
OBJECT-TYPE
This Entry contains the SNMP objects that are used for configurating the Frame Relay Backup.
1.3.6.1.4.1.173.7.3.2.3.1not-accessiblemandatory
portFrBackupRLP
OBJECT-TYPE
This RLP number identifies the RLP containing the primary and backup DLCIs.
1.3.6.1.4.1.173.7.3.2.3.1.1INTEGER (1..8)read-onlymandatory
portFrBackupPort
OBJECT-TYPE
This Port number is the physical port on which the backup DLCI is being configured.
1.3.6.1.4.1.173.7.3.2.3.1.2INTEGER (1..8)read-onlymandatory
portFrBackupDLCI
OBJECT-TYPE
This DLCI number is the backup being configured.
1.3.6.1.4.1.173.7.3.2.3.1.3INTEGER (16..991)read-onlymandatory
portFrBackupGroup
OBJECT-TYPE
This Group number is the backup being configured.
1.3.6.1.4.1.173.7.3.2.3.1.4INTEGER (1..255)read-onlymandatory
portFrBackupWaitTimer
OBJECT-TYPE
This is the time after a primary DLCI failure that the software will wait for this DLCI to become active before checking the next backup DLCI. If the backup does not become active before the timer expires, the software will search the backup group for the next available backup.
1.3.6.1.4.1.173.7.3.2.3.1.5INTEGER (0..65535)read-writemandatory
portFrBackupProtEnab
OBJECT-TYPE
This enables or disables the backup protocol on the specified DLCI. It should be set to yes if and only if the remote device is an FRX4000 or FRX6000 with the backup protocol enabled on the remote DLCI connected to this backup group entry.
1.3.6.1.4.1.173.7.3.2.3.1.6INTEGER {no(1), yes(2)}read-writemandatory
portFrBackupRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the portFrBackupGroupTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.3.2.3.1.7RowStatusread-writemandatory
portBsciGroup
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.3.4
portBsciAdminTable
OBJECT-TYPE
A list of BSC Interactive ports . The number of entries will be the number of BSC Interactive ports on the node.
1.3.6.1.4.1.173.7.3.4.1not-accessiblemandatory
portBsciAdminEntry
OBJECT-TYPE
A BSCI Interactive Port entry containing objects relating to the port that are configurable by the user.
1.3.6.1.4.1.173.7.3.4.1.1not-accessiblemandatory
portBsciAdminBlockedFlag
OBJECT-TYPE
Causes the port to be enabled or disabled at node IPL.
1.3.6.1.4.1.173.7.3.4.1.1.1INTEGER {disabled(1), enabled(2)}read-writemandatory
portBsciAdminConnector
OBJECT-TYPE
Physical port interface connector type.
1.3.6.1.4.1.173.7.3.4.1.1.2INTEGER {rs232(3), v35(5), rs449(6), rs530(7), x21(8), t1(10)}read-writemandatory
portBsciAdminSpeed
OBJECT-TYPE
Data transmission rate in bits per second.
1.3.6.1.4.1.173.7.3.4.1.1.3INTEGER (75..19200)read-writemandatory
portBsciAdminRetransmitInterval
OBJECT-TYPE
Length of time before the node will transmit an I-frame if the previous transmission is not acknowledged.
1.3.6.1.4.1.173.7.3.4.1.1.4INTEGER (1..9999)read-writemandatory
portBsciAdminMAXRetransmits
OBJECT-TYPE
Maximum number of times the node will attempt to send an I-frame after a retransmission period expiration.
1.3.6.1.4.1.173.7.3.4.1.1.5INTEGER (1..99)read-writemandatory
portBsciAdminMaxBytesPerFrame
OBJECT-TYPE
Maximum frame size that will be transmitted on the port.
1.3.6.1.4.1.173.7.3.4.1.1.6INTEGER (25..4105)read-writemandatory
portBsciAdminGenerateClock
OBJECT-TYPE
Specifies whether the port will generate the clock necessary to synchronize traffic over the link.
1.3.6.1.4.1.173.7.3.4.1.1.7INTEGER {no(1), yes(2)}read-writemandatory
portBsciAdminRcvClockFromDTE
OBJECT-TYPE
Allows the clock to be looped back from the DTE using the TT (Terminal Timing) signal.
1.3.6.1.4.1.173.7.3.4.1.1.8INTEGER {no(1), yes(2)}read-writemandatory
portBsciAdminPadType
OBJECT-TYPE
BSCI Pad Type
1.3.6.1.4.1.173.7.3.4.1.1.9INTEGER {tpad(1), hpad(2)}read-writemandatory
portBsciAdminUseEBCDIC
OBJECT-TYPE
Specifies whether all devices on a line use the same character set for successive session polls.
1.3.6.1.4.1.173.7.3.4.1.1.10INTEGER {no(1), yes(2)}read-writemandatory
portBsciAdminCallInfoInRequestPacket
OBJECT-TYPE
Specifies whether the user will have the option of including call information in a call request packet.
1.3.6.1.4.1.173.7.3.4.1.1.11INTEGER {no(1), yes(2)}read-writemandatory
portBsciAdminClearVCOnLastDeviceDown
OBJECT-TYPE
Causes the virtual circuit to be cleared when no terminals are using it.
1.3.6.1.4.1.173.7.3.4.1.1.12INTEGER {no(1), yes(2)}read-writemandatory
portBsciAdminTransTextSupported
OBJECT-TYPE
Causes all characters transmitted to be treated as data.
1.3.6.1.4.1.173.7.3.4.1.1.13INTEGER {no(1), yes(2)}read-writemandatory
portBsciAdminEndToEndAck
OBJECT-TYPE
Allows management of acknowledgments end to end across the network rather than locally at each end.
1.3.6.1.4.1.173.7.3.4.1.1.14INTEGER {no(1), yes(2)}read-writemandatory
portBsciAdminFullDuplex
OBJECT-TYPE
Specifies full-duplex transmission.
1.3.6.1.4.1.173.7.3.4.1.1.15INTEGER {no(1), yes(2)}read-writemandatory
portBsciAdminMultidrop
OBJECT-TYPE
Specifies whether transmission will be multidrop.
1.3.6.1.4.1.173.7.3.4.1.1.16INTEGER {no(1), yes(2)}read-writemandatory
portBsciAdminSlowPollRetryCount
OBJECT-TYPE
Specifies how many times the control unit will be polled before it is put on the slow poll list.
1.3.6.1.4.1.173.7.3.4.1.1.17INTEGER (10..150)read-writemandatory
portBsciAdminSlowPollRetryFreq
OBJECT-TYPE
Specifies the number of times active control units will be polled between pollings on the slow poll list.
1.3.6.1.4.1.173.7.3.4.1.1.18INTEGER (1..200)read-writemandatory
portBsciAdminStartSynchChars
OBJECT-TYPE
Specifies the number of synchronization characters that will be added to the beginning of each frame.
1.3.6.1.4.1.173.7.3.4.1.1.19INTEGER (2..10)read-writemandatory
portBsciAdminEndPadChars
OBJECT-TYPE
Specifies the number of padding characters that will be added to the end of each frame.
1.3.6.1.4.1.173.7.3.4.1.1.20INTEGER (1..10)read-writemandatory
portBsciAdminPollInterval
OBJECT-TYPE
Specifies the time between passes through the polling list.
1.3.6.1.4.1.173.7.3.4.1.1.21INTEGER (100..1000)read-writemandatory
portBsciAdminNoResponseTimer
OBJECT-TYPE
Activated after transmission of a general poll or a data frame.
1.3.6.1.4.1.173.7.3.4.1.1.22INTEGER (2..10)read-writemandatory
portBsciAdminNoResponseRetryCount
OBJECT-TYPE
Specifies how many times the user device will be polled before control is passed on the next cluster.
1.3.6.1.4.1.173.7.3.4.1.1.23INTEGER (1..255)read-writemandatory
portBsciAdminErrorRetransmitCount
OBJECT-TYPE
Specifies the number of times the Netlink device will resend a block of data after the receiving device has detected an error in that block.
1.3.6.1.4.1.173.7.3.4.1.1.24INTEGER (1..255)read-writemandatory
portBsciAdminNAKRetryCount
OBJECT-TYPE
Specifies the number of times the Netlink device will send a frame when the receiving device is unable to acknowledge.
1.3.6.1.4.1.173.7.3.4.1.1.25INTEGER (1..255)read-writemandatory
portBsciAdminBlockCheck
OBJECT-TYPE
Sets the redundancy check parameter.
1.3.6.1.4.1.173.7.3.4.1.1.26INTEGER {crc16(1), even-lrc(2), odd-lrc(3)}read-writemandatory
portBsciAdminDataMode
OBJECT-TYPE
Sets the parity parameter.
1.3.6.1.4.1.173.7.3.4.1.1.27INTEGER {odd-7bit(1), even-7bit(2), none-8bit(3)}read-writemandatory
portBsciAdminRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the portBsciAdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device, and which is supplied by a management station wishing to exercise an on-line update of the existing conceptual row. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.3.4.1.1.28RowStatusread-writemandatory
portBsciAdminAnswerNonConfigured
OBJECT-TYPE
Only valid if pad type is HPAD. If yes, the HPAD will respond to all devices on the line. If no, the HPAD will respond only to those devices that are configured on the node.
1.3.6.1.4.1.173.7.3.4.1.1.29INTEGER {no(1), yes(2)}read-writemandatory
portBsciAdminActivateConnectionWithoutPoll
OBJECT-TYPE
Only valid if pad type is TPAD. If yes, will active the TPAD connection without a poll of the connected device.
1.3.6.1.4.1.173.7.3.4.1.1.30INTEGER {no(1), yes(2)}read-writemandatory
portBsciOperTable
OBJECT-TYPE
A list of BSC Interactive ports . The number of entries will be the number of BSC Interactive ports on the node.
1.3.6.1.4.1.173.7.3.4.2not-accessiblemandatory
portBsciOperEntry
OBJECT-TYPE
A BSCI Interactive Port entry containing objects relating to the port that are configurable by the user.
1.3.6.1.4.1.173.7.3.4.2.1not-accessiblemandatory
portBsciOperBlockedFlag
OBJECT-TYPE
Causes the port to be enabled or disabled at node IPL.
1.3.6.1.4.1.173.7.3.4.2.1.1INTEGER {disabled(1), enabled(2)}read-onlymandatory
portBsciOperConnector
OBJECT-TYPE
Physical port interface connector type.
1.3.6.1.4.1.173.7.3.4.2.1.2INTEGER {rs232(3), v35(5), rs449(6), rs530(7), x21(8), t1(10)}read-onlymandatory
portBsciOperSpeed
OBJECT-TYPE
Data transmission rate in bits per second.
1.3.6.1.4.1.173.7.3.4.2.1.3INTEGERread-onlymandatory
portBsciOperRetransmitInterval
OBJECT-TYPE
Length of time before the node will transmit an I-frame if the previous transmission is not acknowledged.
1.3.6.1.4.1.173.7.3.4.2.1.4INTEGER (1..9999)read-onlymandatory
portBsciOperMAXRetransmits
OBJECT-TYPE
Maximum number of times the node will attempt to send an I-frame after a retransmission period expiration.
1.3.6.1.4.1.173.7.3.4.2.1.5INTEGER (1..99)read-onlymandatory
portBsciOperMaxBytesPerFrame
OBJECT-TYPE
Maximum frame size that will be transmitted on the port.
1.3.6.1.4.1.173.7.3.4.2.1.6INTEGER (25..4105)read-onlymandatory
portBsciOperGenerateClock
OBJECT-TYPE
Specifies whether the port will generate the clock necessary to synchronize traffic over the link.
1.3.6.1.4.1.173.7.3.4.2.1.7INTEGER {no(1), yes(2)}read-onlymandatory
portBsciOperRcvClockFromDTE
OBJECT-TYPE
Allows the clock to be looped back from the DTE using the TT (Terminal Timing) signal.
1.3.6.1.4.1.173.7.3.4.2.1.8INTEGER {no(1), yes(2)}read-onlymandatory
portBsciOperPadType
OBJECT-TYPE
BSCI Pad Type
1.3.6.1.4.1.173.7.3.4.2.1.9INTEGER {tpad(1), hpad(2)}read-onlymandatory
portBsciOperUseEBCDIC
OBJECT-TYPE
Specifies whether all devices on a line use the same character set for successive session polls.
1.3.6.1.4.1.173.7.3.4.2.1.10INTEGER {no(1), yes(2)}read-onlymandatory
portBsciOperCallInfoInRequestPacket
OBJECT-TYPE
Specifies whether the user will have the option of including call information in a call request packet.
1.3.6.1.4.1.173.7.3.4.2.1.11INTEGER {no(1), yes(2)}read-onlymandatory
portBsciOperClearVCOnLastDeviceDown
OBJECT-TYPE
Causes the virtual circuit to be cleared when no terminals are using it.
1.3.6.1.4.1.173.7.3.4.2.1.12INTEGER {no(1), yes(2)}read-onlymandatory
portBsciOperTransTextSupported
OBJECT-TYPE
Causes all characters transmitted to be treated as data.
1.3.6.1.4.1.173.7.3.4.2.1.13INTEGER {no(1), yes(2)}read-onlymandatory
portBsciOperEndToEndAck
OBJECT-TYPE
Allows management of acknowledgments end to end across the network rather than locally at each end.
1.3.6.1.4.1.173.7.3.4.2.1.14INTEGER {no(1), yes(2)}read-onlymandatory
portBsciOperFullDuplex
OBJECT-TYPE
Specifies full-duplex transmission.
1.3.6.1.4.1.173.7.3.4.2.1.15INTEGER {no(1), yes(2)}read-onlymandatory
portBsciOperMultidrop
OBJECT-TYPE
Specifies whether transmission will be multidrop.
1.3.6.1.4.1.173.7.3.4.2.1.16INTEGER {no(1), yes(2)}read-onlymandatory
portBsciOperSlowPollRetryCount
OBJECT-TYPE
Specifies how many times the control unit will be polled before it is put on the slow poll list.
1.3.6.1.4.1.173.7.3.4.2.1.17INTEGER (10..150)read-onlymandatory
portBsciOperSlowPollRetryFreq
OBJECT-TYPE
Specifies the number of times active control units will be polled between pollings on the slow poll list.
1.3.6.1.4.1.173.7.3.4.2.1.18INTEGER (1..200)read-onlymandatory
portBsciOperStartSynchChars
OBJECT-TYPE
Specifies the number of synchronization characters that will be added to the beginning of each frame.
1.3.6.1.4.1.173.7.3.4.2.1.19INTEGER (2..10)read-onlymandatory
portBsciOperEndPadChars
OBJECT-TYPE
Specifies the number of padding characters that will be added to the end of each frame.
1.3.6.1.4.1.173.7.3.4.2.1.20INTEGER (1..10)read-onlymandatory
portBsciOperPollInterval
OBJECT-TYPE
Specifies the time between passes through the polling list.
1.3.6.1.4.1.173.7.3.4.2.1.21INTEGER (100..1000)read-onlymandatory
portBsciOperNoResponseTimer
OBJECT-TYPE
Activated after transmission of a general poll or a data frame.
1.3.6.1.4.1.173.7.3.4.2.1.22INTEGER (2..10)read-onlymandatory
portBsciOperNoResponseRetryCount
OBJECT-TYPE
Specifies how many times the user device will be polled before control is passed on the next cluster.
1.3.6.1.4.1.173.7.3.4.2.1.23INTEGER (1..255)read-onlymandatory
portBsciOperErrorRetransmitCount
OBJECT-TYPE
Specifies the number of times the Netlink device will resend a block of data after the receiving device has detected an error in that block.
1.3.6.1.4.1.173.7.3.4.2.1.24INTEGER (1..255)read-onlymandatory
portBsciOperNAKRetryCount
OBJECT-TYPE
Specifies the number of times the Netlink device will send a frame when the receiving device is unable to acknowledge.
1.3.6.1.4.1.173.7.3.4.2.1.25INTEGER (1..255)read-onlymandatory
portBsciOperBlockCheck
OBJECT-TYPE
Sets the redundancy check parameter.
1.3.6.1.4.1.173.7.3.4.2.1.26INTEGER {crc16(1), even-lrc(2), odd-lrc(3)}read-onlymandatory
portBsciOperDataMode
OBJECT-TYPE
Sets the parity parameter.
1.3.6.1.4.1.173.7.3.4.2.1.27INTEGER {odd-7bit(1), even-7bit(2), none-8bit(3)}read-onlymandatory
portBsciOperAnswerNonConfigured
OBJECT-TYPE
Only valid if pad type is HPAD. If yes, the HPAD will respond to all devices on the line. If no, the HPAD will respond only to those devices that are configured on the node.
1.3.6.1.4.1.173.7.3.4.2.1.28INTEGER {no(1), yes(2)}read-onlymandatory
portBsciOperActivateConnectionWithoutPoll
OBJECT-TYPE
Only valid if pad type is TPAD. If yes, will active the TPAD connection without a poll of the connected device.
1.3.6.1.4.1.173.7.3.4.2.1.29INTEGER {no(1), yes(2)}read-onlymandatory
bsciSubscrAdminTable
OBJECT-TYPE
A list of BSC Interactive port subscribers.
1.3.6.1.4.1.173.7.3.4.3not-accessiblemandatory
bsciSubscrAdminEntry
OBJECT-TYPE
A BSCI Interactive Port Subscriber entry containing objects relating to the port that are configurable by the user.
1.3.6.1.4.1.173.7.3.4.3.1not-accessiblemandatory
bsciSubscrAdminSequence
OBJECT-TYPE
Subscriber index for a specific BSCI port subscriber.
1.3.6.1.4.1.173.7.3.4.3.1.1INTEGER (1..16)read-onlymandatory
bsciSubscrAdminLocalID
OBJECT-TYPE
Subscriber address of the local end of a BSCI connection.
1.3.6.1.4.1.173.7.3.4.3.1.2NlSubscriberAddressread-writemandatory
bsciSubscrAdminRemoteID
OBJECT-TYPE
Subscriber address of the remote end of a BSCI connection.
1.3.6.1.4.1.173.7.3.4.3.1.3NlSubscriberAddressread-writemandatory
bsciSubscrAdminAutocall
OBJECT-TYPE
Causes a BSCI TPAD to automatically call its HPAD when the controller becomes active.
1.3.6.1.4.1.173.7.3.4.3.1.4INTEGER {no(1), yes(2)}read-writemandatory
bsciSubscrAdminAutocallRtyTimer
OBJECT-TYPE
Time between autocall retries.
1.3.6.1.4.1.173.7.3.4.3.1.5INTEGER (15..255)read-writemandatory
bsciSubscrAdminAutocallMaxRtry
OBJECT-TYPE
Maximum number of times an autocall will be sent.
1.3.6.1.4.1.173.7.3.4.3.1.6INTEGER (0..255)read-writemandatory
bsciSubscrAdminConnectionID
OBJECT-TYPE
Identifier that will link the BSCI port with a device configured in the BSCI Devices Table.
1.3.6.1.4.1.173.7.3.4.3.1.7INTEGER (0..255)read-writemandatory
bsciSubscrAdminRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the bsciDevAdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.3.4.3.1.8RowStatusread-writemandatory
bsciSubscrOperTable
OBJECT-TYPE
A list of BSC Interactive port subscribers.
1.3.6.1.4.1.173.7.3.4.4not-accessiblemandatory
bsciSubscrOperEntry
OBJECT-TYPE
A BSCI Interactive Port Subscriber entry containing objects relating to the port that are configurable by the user.
1.3.6.1.4.1.173.7.3.4.4.1not-accessiblemandatory
bsciSubscrOperSequence
OBJECT-TYPE
Subscriber index for a specific BSCI port subscriber.
1.3.6.1.4.1.173.7.3.4.4.1.1INTEGER (1..16)read-onlymandatory
bsciSubscrOperLocalID
OBJECT-TYPE
Subscriber address of the local end of a BSCI connection.
1.3.6.1.4.1.173.7.3.4.4.1.2NlSubscriberAddressread-onlymandatory
bsciSubscrOperRemoteID
OBJECT-TYPE
Subscriber address of the remote end of a BSCI connection.
1.3.6.1.4.1.173.7.3.4.4.1.3NlSubscriberAddressread-onlymandatory
bsciSubscrOperAutocall
OBJECT-TYPE
Causes a BSCI TPAD to automatically call its HPAD when the controller becomes active.
1.3.6.1.4.1.173.7.3.4.4.1.4INTEGER {no(1), yes(2)}read-onlymandatory
bsciSubscrOperAutocallRtyTimer
OBJECT-TYPE
Time between autocall retries.
1.3.6.1.4.1.173.7.3.4.4.1.5INTEGER (15..255)read-onlymandatory
bsciSubscrOperAutocallMaxRtry
OBJECT-TYPE
Maximum number of times an autocall will be sent.
1.3.6.1.4.1.173.7.3.4.4.1.6INTEGER (0..255)read-onlymandatory
bsciSubscrOperConnectionID
OBJECT-TYPE
Identifier that will link the BSCI port with a device configured in the BSCI Devices Table.
1.3.6.1.4.1.173.7.3.4.4.1.7INTEGER (0..255)read-onlymandatory
bsciDevAdminTable
OBJECT-TYPE
A list of BSC Interactive devices.
1.3.6.1.4.1.173.7.3.4.5not-accessiblemandatory
bsciDevAdminEntry
OBJECT-TYPE
A BSCI Interactive Device entry containing objects relating to the device that are configurable by the user.
1.3.6.1.4.1.173.7.3.4.5.1not-accessiblemandatory
bsciDevAdminControlUnitID
OBJECT-TYPE
Control Unit identifier.
1.3.6.1.4.1.173.7.3.4.5.1.1INTEGER (0..31)read-onlymandatory
bsciDevAdminDeviceUnitID
OBJECT-TYPE
Device Unit identifier.
1.3.6.1.4.1.173.7.3.4.5.1.2INTEGER (0..31)read-onlymandatory
bsciDevAdminConnectionID
OBJECT-TYPE
The BSCI port connection ID for the device.
1.3.6.1.4.1.173.7.3.4.5.1.3INTEGER (0..255)read-writemandatory
bsciDevAdminSingleUserVC
OBJECT-TYPE
Specifies whether each end of the connection is within a same Control Unit/Device Type pair.
1.3.6.1.4.1.173.7.3.4.5.1.4INTEGER {no(1), yes(2)}read-writemandatory
bsciDevAdminTransTextSupported
OBJECT-TYPE
Causes all characters transmitted to be treated as data.
1.3.6.1.4.1.173.7.3.4.5.1.5INTEGER {no(1), yes(2)}read-writemandatory
bsciDevAdminPrinterAttached
OBJECT-TYPE
Specifies whether the device has a printer attached.
1.3.6.1.4.1.173.7.3.4.5.1.6INTEGER {no(1), yes(2)}read-writemandatory
bsciDevAdminRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the bsciDevAdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.3.4.5.1.7RowStatusread-writemandatory
bsciDevAdminDisableStatusRequest
OBJECT-TYPE
Determines how the BSCI port will report the status of the attached device. Normal status- the port will report what the device reports. No status- the port will report status only if the device is active. Always active status- the port will always report the device as active.
1.3.6.1.4.1.173.7.3.4.5.1.8INTEGER {normal(1), none(2), always-active(3)}read-writemandatory
bsciDevOperTable
OBJECT-TYPE
A list of BSC Interactive devices.
1.3.6.1.4.1.173.7.3.4.6not-accessiblemandatory
bsciDevOperEntry
OBJECT-TYPE
A BSCI Interactive Device entry containing objects relating to the device that are configurable by the user.
1.3.6.1.4.1.173.7.3.4.6.1not-accessiblemandatory
bsciDevOperControlUnitID
OBJECT-TYPE
Control Unit identifier.
1.3.6.1.4.1.173.7.3.4.6.1.1INTEGER (0..31)read-onlymandatory
bsciDevOperDeviceUnitID
OBJECT-TYPE
Device Unit identifier.
1.3.6.1.4.1.173.7.3.4.6.1.2INTEGER (0..31)read-onlymandatory
bsciDevOperConnectionID
OBJECT-TYPE
The BSCI port connection ID for the device.
1.3.6.1.4.1.173.7.3.4.6.1.3INTEGER (0..255)read-onlymandatory
bsciDevOperSingleUserVC
OBJECT-TYPE
Specifies whether each end of the connection is within a same Control Unit/Device Type pair.
1.3.6.1.4.1.173.7.3.4.6.1.4INTEGER {no(1), yes(2)}read-onlymandatory
bsciDevOperTransTextSupported
OBJECT-TYPE
Causes all characters transmitted to be treated as data.
1.3.6.1.4.1.173.7.3.4.6.1.5INTEGER {no(1), yes(2)}read-onlymandatory
bsciDevOperPrinterAttached
OBJECT-TYPE
Specifies whether the device has a printer attached.
1.3.6.1.4.1.173.7.3.4.6.1.6INTEGER {no(1), yes(2)}read-onlymandatory
bsciDevOperDisableStatusRequest
OBJECT-TYPE
Determines how the BSCI port will report the status of the attached device. Normal status- the port will report what the device reports. No status- the port will report status only if the device is active. Always active status- the port will always report the device as active.
1.3.6.1.4.1.173.7.3.4.6.1.7INTEGER {normal(1), none(2), always-active(3)}read-onlymandatory
portSdlcGroup
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.3.5
portSdlcAdminTable
OBJECT-TYPE
This table contains Netlink Enterprise specific objects to manage SDLC port. Changing on of the these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation. Most of the objects in this read-write table have corresponding read-only objects in the portSdlcOperTable that return the current operating value. The operating values may be different from these configured values if a configured parameter was configured afterthe interface was started.
1.3.6.1.4.1.173.7.3.5.1not-accessiblemandatory
portSdlcAdminEntry
OBJECT-TYPE
A list of configured values for an SDLC port.
1.3.6.1.4.1.173.7.3.5.1.1not-accessiblemandatory
portSdlcAdminCommit
OBJECT-TYPE
Writing a value to this object commits the the SDLC port related modified configuration values to the database.
1.3.6.1.4.1.173.7.3.5.1.1.1INTEGERread-writeobsolete
portSdlcAdminMAXRetries
OBJECT-TYPE
This object defines the max. number of retries to a non-responding Link station, before putting the Link station to slow-poll list if it is not Normal response Mode OR disconnecting the link station if it is data txfr state.
1.3.6.1.4.1.173.7.3.5.1.1.2INTEGER (0..99)read-writemandatory
portSdlcAdminMAXOut
OBJECT-TYPE
This object defines the number of outstanding frames for triggering window full condition.
1.3.6.1.4.1.173.7.3.5.1.1.3INTEGER (1..7)read-writemandatory
portSdlcAdminPadType
OBJECT-TYPE
This object defines the SNA PAD types.
1.3.6.1.4.1.173.7.3.5.1.1.4INTEGER {xpad(1), tpad(2), hpad(3), npad(4)}read-writemandatory
portSdlcAdminGenerateClock
OBJECT-TYPE
This object defines if the port would generate clock.
1.3.6.1.4.1.173.7.3.5.1.1.5INTEGER {no(1), yes(2)}read-writemandatory
portSdlcAdminRcvClockFromDTE
OBJECT-TYPE
This object defines if the rcv clock will be used from DTE.
1.3.6.1.4.1.173.7.3.5.1.1.6INTEGER {no(1), yes(2)}read-writemandatory
portSdlcAdminNrz
OBJECT-TYPE
This object defines the data encoding at the physical layer
1.3.6.1.4.1.173.7.3.5.1.1.7INTEGER {no(1), yes(2)}read-writemandatory
portSdlcAdminPacketSize
OBJECT-TYPE
This object defines the packet size of the X25 layer used by SNA PAD
1.3.6.1.4.1.173.7.3.5.1.1.8INTEGER (16..4096)read-writemandatory
portSdlcAdminDisableRequestDisconnect
OBJECT-TYPE
This object defines if a Request To Disconnect(RD) will be sent when remote PAD clear the connection
1.3.6.1.4.1.173.7.3.5.1.1.9INTEGER {no(1), yes(2)}read-writemandatory
portSdlcAdminLPDASupport
OBJECT-TYPE
This object defines the type LPDA support on SDLC port.
1.3.6.1.4.1.173.7.3.5.1.1.10INTEGER {none(1), lpda-1(2), lpda-2(3)}read-writemandatory
portSdlcAdminConnector
OBJECT-TYPE
This object defines the connector type of the SDLC port.
1.3.6.1.4.1.173.7.3.5.1.1.11INTEGER {rs232(3), v35(5), rs449(6), rs530(7), x21(8), t1(10)}read-writemandatory
portSdlcAdminSpeed
OBJECT-TYPE
This object defines the speed of the SDLC port. The speed may only be set to one of a series of reasonable values, and if an attempt is made to set the speed to a value which is within the valid range but not equal to one of these values, the speed will be rounded up. If the connector type of the port is RS232, the port could be a standard port or a high speed port. If the port is a high speed RS232 port, the maximum valid speed is 256000. If the port is a standard RS232 port, the maximum valid speed is 64000 on the FRX4000/SS1840 and 19200 on all other products. It may be possible to set the speed of a standard RS232 port to a speed which is valid for a high speed RS232 port but invalid for a standard RS232 port. In this case, the port may not end up having the invalid speed. The default speed for a standard RS232 port on the FRX6000 is 19200.
1.3.6.1.4.1.173.7.3.5.1.1.12INTEGER (75..2048000)read-writemandatory
portSdlcAdminRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the portSdlcAdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device, and which is supplied by a management station wishing to exercise an on-line update of the existing conceptual row. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.3.5.1.1.13RowStatusread-writemandatory
portSdlcAdminIdleFillChar
OBJECT-TYPE
This object specifies a character that wll be inserted into the stream when the SNA link is idle.
1.3.6.1.4.1.173.7.3.5.1.1.14INTEGER {hex-ff(1), hex-7e(2)}read-writemandatory
portSdlcAdminInactivityTimer
OBJECT-TYPE
This object determines how long the node will wait with no activity on the port before it will declare the attached device down.
1.3.6.1.4.1.173.7.3.5.1.1.15INTEGER (15..250)read-writemandatory
portSdlcAdminL1Duplex
OBJECT-TYPE
This object determines whether level-1 (physical layer) transmission can be in one (half duplex) or both (full duplex) directions at once.
1.3.6.1.4.1.173.7.3.5.1.1.16INTEGER {full-duplex(1), half-duplex(2)}read-writemandatory
portSdlcOperTable
OBJECT-TYPE
This table contains current Netlink enterprise specific port parameters
1.3.6.1.4.1.173.7.3.5.2not-accessiblemandatory
portSdlcOperEntry
OBJECT-TYPE
A list of operational values for an SDLC port.
1.3.6.1.4.1.173.7.3.5.2.1not-accessiblemandatory
portSdlcOperCommit
OBJECT-TYPE
This object is not used.
1.3.6.1.4.1.173.7.3.5.2.1.1INTEGERread-onlyobsolete
portSdlcOperMAXRetries
OBJECT-TYPE
This object defines the max. number of retries to a non-responding Link station, before putting the Link station to slow-poll list if it is not Normal response Mode OR disconnecting the link station if it is data txfr state.
1.3.6.1.4.1.173.7.3.5.2.1.2INTEGER (0..99)read-onlymandatory
portSdlcOperMAXOut
OBJECT-TYPE
This object defines the number of outstanding frames for triggering window full condition.
1.3.6.1.4.1.173.7.3.5.2.1.3INTEGER (1..7)read-onlymandatory
portSdlcOperPadType
OBJECT-TYPE
This object defines the SNA PAD type
1.3.6.1.4.1.173.7.3.5.2.1.4INTEGER {xpad(1), tpad(2), hpad(3), npad(4)}read-onlymandatory
portSdlcOperGenerateClock
OBJECT-TYPE
This object defines if the port would generate clock.
1.3.6.1.4.1.173.7.3.5.2.1.5INTEGER {no(1), yes(2)}read-onlymandatory
portSdlcOperRcvClockFromDTE
OBJECT-TYPE
This object defines if the rcv clock will be used from DTE.
1.3.6.1.4.1.173.7.3.5.2.1.6INTEGER {no(1), yes(2)}read-onlymandatory
portSdlcOperNrz
OBJECT-TYPE
This object defines the data encoding at the physical layer
1.3.6.1.4.1.173.7.3.5.2.1.7INTEGER {no(1), yes(2)}read-onlymandatory
portSdlcOperPacketSize
OBJECT-TYPE
This object defines the packet size of the X25 layer used by SNA PAD
1.3.6.1.4.1.173.7.3.5.2.1.8INTEGER (16..4096)read-onlymandatory
portSdlcOperDisableRequestDisconnect
OBJECT-TYPE
This object defines if a Request To Disconnect(RD) will be sent when remote PAD clear the connection
1.3.6.1.4.1.173.7.3.5.2.1.9INTEGER {no(1), yes(2)}read-onlymandatory
portSdlcOperLPDASupport
OBJECT-TYPE
This object defines the type LPDA support on SDLC port.
1.3.6.1.4.1.173.7.3.5.2.1.10INTEGER {none(1), lpda-1(2), lpda-2(3)}read-onlymandatory
portSdlcOperConnector
OBJECT-TYPE
This object defines the operational connector type of the SDLC port.
1.3.6.1.4.1.173.7.3.5.2.1.11INTEGER {rs232(3), v35(5), rs449(6), rs530(7), x21(8), t1(10)}read-onlymandatory
portSdlcOperSpeed
OBJECT-TYPE
This object defines the operational speed of the SDLC port.
1.3.6.1.4.1.173.7.3.5.2.1.12INTEGERread-onlymandatory
portSdlcOperIdleFillChar
OBJECT-TYPE
This object specifies a character that wll be inserted into the stream when the SNA link is idle.
1.3.6.1.4.1.173.7.3.5.2.1.13INTEGER {hex-ff(1), hex-7e(2)}read-onlymandatory
portSdlcOperInactivityTimer
OBJECT-TYPE
This object determines how long the node will wait with no activity on the port before it will declare the attached device down.
1.3.6.1.4.1.173.7.3.5.2.1.14INTEGER (15..250)read-onlymandatory
portSdlcOperL1Duplex
OBJECT-TYPE
This object determines whether level-1 (physical layer) transmission can be in one (half duplex) or both (full duplex) directions at once.
1.3.6.1.4.1.173.7.3.5.2.1.15INTEGER {full-duplex(1), half-duplex(2)}read-onlymandatory
lSSdlcAdminTable
OBJECT-TYPE
This table contains Enterprise specific Link station configurable parameters to manage the link stations.
1.3.6.1.4.1.173.7.3.5.3not-accessiblemandatory
lSSdlcAdminEntry
OBJECT-TYPE
A list of configured values for an SDLC port.
1.3.6.1.4.1.173.7.3.5.3.1not-accessiblemandatory
lSSdlcAdminLocalSub
OBJECT-TYPE
This object defines the local subscriber ID of the Link Station
1.3.6.1.4.1.173.7.3.5.3.1.1NlSubscriberAddressread-writemandatory
lSSdlcAdminRemoteSub
OBJECT-TYPE
This object defines the remote subscriber ID used to connect to remote Link Station
1.3.6.1.4.1.173.7.3.5.3.1.2NlSubscriberAddressread-writemandatory
lSSdlcAdminAutoCall
OBJECT-TYPE
This object defines if auto call is enabled for the link station. If enabled, the link station will initiate connection establishment, when appropriate. Else, it will passively listen to the connection request for establish a connection with the remote PAD
1.3.6.1.4.1.173.7.3.5.3.1.3INTEGER {no(1), yes(2)}read-writemandatory
lSSdlcAdminRetryTime
OBJECT-TYPE
This object is used, only when lSSdlcAdminAutoCall object is yes. This defines the time interval measured in seconds in which the connection request is retried
1.3.6.1.4.1.173.7.3.5.3.1.4INTEGER (15..225)read-writemandatory
lSSdlcAdminRetryCount
OBJECT-TYPE
This object is used, only when lSSdlcAdminAutoCall object is yes. This defines the number of times the connection initiation is retried before given up. The value of Zero(0) means to try indefinitely
1.3.6.1.4.1.173.7.3.5.3.1.5INTEGER (0..255)read-writemandatory
lSSdlcAdminLlc2Conversion
OBJECT-TYPE
This object defines if this link station connects to a LLC2 device/host.
1.3.6.1.4.1.173.7.3.5.3.1.6INTEGER {no(1), yes(2)}read-writemandatory
lSSdlcAdminLPDAResourceID
OBJECT-TYPE
This objects the resource ID used during LPDA command support
1.3.6.1.4.1.173.7.3.5.3.1.7INTEGER (0..255)read-writemandatory
lSSdlcAdminRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the lSSdlcAdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. Also note that deleting a PU entry will only remove it from the database file, and it's existence will still be known by the protocol until the node is rebooted or until an online update of the port is performed.
1.3.6.1.4.1.173.7.3.5.3.1.8RowStatusread-writemandatory
lSSdlcAdminL2DatMode
OBJECT-TYPE
This object determines whether transmission can be in one (alternate) or two (simultaneous) directions at the same time.
1.3.6.1.4.1.173.7.3.5.3.1.9INTEGER {two-way-alternate(1), two-way-simultaneous(2)}read-writemandatory
lSSdlcOperTable
OBJECT-TYPE
This table contains the operational parameters of the SDLC port
1.3.6.1.4.1.173.7.3.5.4not-accessiblemandatory
lSSdlcOperEntry
OBJECT-TYPE
A list of configured values for an SDLC port.
1.3.6.1.4.1.173.7.3.5.4.1not-accessiblemandatory
lSSdlcOperLocalSub
OBJECT-TYPE
This object defines the local subscriber ID of the Link Station
1.3.6.1.4.1.173.7.3.5.4.1.1NlSubscriberAddressread-onlymandatory
lSSdlcOperRemoteSub
OBJECT-TYPE
This object defines the remote subscriber ID used to connect to remote Link Station
1.3.6.1.4.1.173.7.3.5.4.1.2NlSubscriberAddressread-onlymandatory
lSSdlcOperAutoCall
OBJECT-TYPE
This object defines if auto call is enabled for the link station. If enabled, the link station will initiate connection establishment, when appropriate. Else, it will passively listen to the connection request for establish a connection with the remote PAD
1.3.6.1.4.1.173.7.3.5.4.1.3INTEGER {no(1), yes(2)}read-onlymandatory
lSSdlcOperRetryTime
OBJECT-TYPE
This object is valid, only when lSSdlcAdminAutoCall object is yes. This defines the time interval measured in seconds in which the connection request is retried
1.3.6.1.4.1.173.7.3.5.4.1.4INTEGER (15..225)read-onlymandatory
lSSdlcOperRetryCount
OBJECT-TYPE
This object is used, only when lSSdlcAdminAutoCall object is yes. This defines the number of times the connection initiation is retried before given up. The value of Zero(0) means to try indefinitely
1.3.6.1.4.1.173.7.3.5.4.1.5INTEGER (0..255)read-onlymandatory
lSSdlcOperLlc2Conversion
OBJECT-TYPE
This object defines if this link station connects to a LLC2 device/host.
1.3.6.1.4.1.173.7.3.5.4.1.6INTEGER {no(1), yes(2)}read-onlymandatory
lSSdlcOperLPDAResourceID
OBJECT-TYPE
This objects the resource ID used during LPDA command support
1.3.6.1.4.1.173.7.3.5.4.1.7INTEGER (0..255)read-onlymandatory
lSSdlcOperL2DatMode
OBJECT-TYPE
This object determines whether transmission can be in one (alternate) or two (simultaneous) directions at the same time.
1.3.6.1.4.1.173.7.3.5.4.1.8INTEGER {two-way-alternate(1), two-way-simultaneous(2)}read-onlymandatory
lSSdlcLlc2AdminTable
OBJECT-TYPE
This table contains the LLC2 related parameters used to configure LLC2 session, when the SDLC station is connected to a LLC2 device at the remote end
1.3.6.1.4.1.173.7.3.5.5not-accessiblemandatory
lSSdlcLlc2AdminEntry
OBJECT-TYPE
A list of configured values for an SDLC port.
1.3.6.1.4.1.173.7.3.5.5.1not-accessiblemandatory
lSSdlcLlc2AdminLocalSap
OBJECT-TYPE
This object defines Local SAP address (multiple of 4)
1.3.6.1.4.1.173.7.3.5.5.1.1INTEGER (0..252)read-writemandatory
lSSdlcLlc2AdminLocalMac
OBJECT-TYPE
This object defines the local MAC address
1.3.6.1.4.1.173.7.3.5.5.1.2PhysAddressread-writemandatory
lSSdlcLlc2AdminIdblk
OBJECT-TYPE
This object defines idblk used in XID
1.3.6.1.4.1.173.7.3.5.5.1.3INTEGER (0..4095)read-writemandatory
lSSdlcLlc2AdminIdnum
OBJECT-TYPE
This object defines idnum used in XID
1.3.6.1.4.1.173.7.3.5.5.1.4INTEGER (0..1048575)read-writemandatory
lSSdlcLlc2AdminLanTi
OBJECT-TYPE
This object defines LLC2 inactivity timer measured in units of seconds
1.3.6.1.4.1.173.7.3.5.5.1.5INTEGER (1..50)read-writemandatory
lSSdlcLlc2AdminLanT1
OBJECT-TYPE
This object defines LLC2 reply timer measured in units of 100 milliseconds
1.3.6.1.4.1.173.7.3.5.5.1.6INTEGER (1..250)read-writemandatory
lSSdlcLlc2AdminLanT2
OBJECT-TYPE
This object defines Receiver Ack Timer measured in units of milliseconds
1.3.6.1.4.1.173.7.3.5.5.1.7INTEGER (100..5000)read-writemandatory
lSSdlcLlc2AdminLanN2
OBJECT-TYPE
This object defines Maximum Retransmissions
1.3.6.1.4.1.173.7.3.5.5.1.8INTEGER (0..255)read-writemandatory
lSSdlcLlc2AdminLanN3
OBJECT-TYPE
This object defines count of I-format LPDU's before sending Ack
1.3.6.1.4.1.173.7.3.5.5.1.9INTEGER (1..127)read-writemandatory
lSSdlcLlc2AdminLanTw
OBJECT-TYPE
This object defines Outstanding Frames
1.3.6.1.4.1.173.7.3.5.5.1.10INTEGER (1..127)read-writemandatory
lSSdlcLlc2AdminBAG
OBJECT-TYPE
This object defines bandwidth allocation group
1.3.6.1.4.1.173.7.3.5.5.1.11INTEGER (0..16)read-writemandatory
lSSdlcLlc2AdminPriority
OBJECT-TYPE
This object defines priority for traffic within the node
1.3.6.1.4.1.173.7.3.5.5.1.12INTEGER (0..9)read-writemandatory
lSSdlcLlc2AdminRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the lSSdlcLlc2AdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. Also note that deleting a PU entry will only remove it from the database file, and it's existence will still be known by the protocol until the node is rebooted or until an online update of the port is performed.
1.3.6.1.4.1.173.7.3.5.5.1.13RowStatusread-writemandatory
lSSdlcLlc2AdminSuppressXID
OBJECT-TYPE
This object prevents (if yes) the returning of an XID in response to a null XID. This might be desirable if the remote TPAD is not running PU 2.1. It should be noted that even if an XID is sent, an SNRM (Set Normal Response Mode) immediately follows, so the connection will be established.
1.3.6.1.4.1.173.7.3.5.5.1.14INTEGER {no(1), yes(2)}read-writemandatory
lSSdlcLlc2OperTable
OBJECT-TYPE
This table contains operartional parameters related to LLC2 session of this link station.
1.3.6.1.4.1.173.7.3.5.6not-accessiblemandatory
lSSdlcLlc2OperEntry
OBJECT-TYPE
A list of configured values for an SDLC port.
1.3.6.1.4.1.173.7.3.5.6.1not-accessiblemandatory
lSSdlcLlc2OperLocalSap
OBJECT-TYPE
This object defines Local SAP address (multiple of 4)
1.3.6.1.4.1.173.7.3.5.6.1.1INTEGER (0..252)read-onlymandatory
lSSdlcLlc2OperLocalMac
OBJECT-TYPE
This object defines the local MAC address
1.3.6.1.4.1.173.7.3.5.6.1.2PhysAddressread-onlymandatory
lSSdlcLlc2OperIdblk
OBJECT-TYPE
This object defines idblk used in XID
1.3.6.1.4.1.173.7.3.5.6.1.3INTEGER (0..4095)read-onlymandatory
lSSdlcLlc2OperIdnum
OBJECT-TYPE
This object defines idnum used in XID
1.3.6.1.4.1.173.7.3.5.6.1.4INTEGER (0..1048575)read-onlymandatory
lSSdlcLlc2OperLanTi
OBJECT-TYPE
This object defines LLC2 inactivity timer measured in units of seconds
1.3.6.1.4.1.173.7.3.5.6.1.5INTEGER (1..50)read-onlymandatory
lSSdlcLlc2OperLanT1
OBJECT-TYPE
This object defines LLC2 reply timer measured in units of 100 milliseconds
1.3.6.1.4.1.173.7.3.5.6.1.6INTEGER (1..250)read-onlymandatory
lSSdlcLlc2OperLanT2
OBJECT-TYPE
This object defines Receiver Ack Timer measured in units of milliseconds
1.3.6.1.4.1.173.7.3.5.6.1.7INTEGER (100..5000)read-onlymandatory
lSSdlcLlc2OperLanN2
OBJECT-TYPE
This object defines Maximum Retransmissions
1.3.6.1.4.1.173.7.3.5.6.1.8INTEGER (0..255)read-onlymandatory
lSSdlcLlc2OperLanN3
OBJECT-TYPE
This object defines count of I-format LPDU's before sending Ack
1.3.6.1.4.1.173.7.3.5.6.1.9INTEGER (1..127)read-onlymandatory
lSSdlcLlc2OperLanTw
OBJECT-TYPE
This object defines Outstanding Frames
1.3.6.1.4.1.173.7.3.5.6.1.10INTEGER (1..127)read-onlymandatory
lSSdlcLlc2OperBAG
OBJECT-TYPE
This object defines bandwidth allocation group
1.3.6.1.4.1.173.7.3.5.6.1.11INTEGER (0..16)read-onlymandatory
lSSdlcLlc2OperPriority
OBJECT-TYPE
This object defines priority for traffic within the node
1.3.6.1.4.1.173.7.3.5.6.1.12INTEGER (0..9)read-onlymandatory
lSSdlcLlc2OperSuppressXID
OBJECT-TYPE
This object prevents (if yes) the returning of an XID in response to a null XID. This might be desirable if the remote TPAD is not running PU 2.1. It should be noted that even if an XID is sent, an SNRM (Set Normal Response Mode) immediately follows, so the connection will be established.
1.3.6.1.4.1.173.7.3.5.6.1.13INTEGER {no(1), yes(2)}read-onlymandatory
portT1Group
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.3.7
portT1AdminTable
OBJECT-TYPE
The configuration information pertaining to a T1 port. T1 ports can operate at full T1 bandwidth or DS0A channelized which provides 24 separate channels.
1.3.6.1.4.1.173.7.3.7.1not-accessiblemandatory
portT1AdminEntry
OBJECT-TYPE
A T1 port entry containing objects relating to T1 ports.
1.3.6.1.4.1.173.7.3.7.1.1not-accessiblemandatory
portT1AdminBlockedPortFlag
OBJECT-TYPE
1.3.6.1.4.1.173.7.3.7.1.1.1INTEGER {no(1), yes(2)}read-writemandatory
portT1AdminGenerateClock
OBJECT-TYPE
1.3.6.1.4.1.173.7.3.7.1.1.2INTEGER {no(1), yes(2)}read-writemandatory
portT1AdminFramingMode
OBJECT-TYPE
Specifies how this T1 port is to function. ds0AT1 specifies a 24 channelized T1.
1.3.6.1.4.1.173.7.3.7.1.1.3INTEGER {fullT1(1), ds0aT1(2)}read-writemandatory
portT1AdminFrameModelSelect
OBJECT-TYPE
1.3.6.1.4.1.173.7.3.7.1.1.4INTEGER {d4(1), esf(2)}read-writemandatory
portT1AdminLineEncoding
OBJECT-TYPE
1.3.6.1.4.1.173.7.3.7.1.1.5INTEGER {b8zs(1), ami(2)}read-writemandatory
portT1AdminLineBuildOut
OBJECT-TYPE
1.3.6.1.4.1.173.7.3.7.1.1.6INTEGER {zerodb(1), x133-266ft(2), x266-399ft(3), x399-533ft(4), x533-655ft(5), minus7p5db(6), minus15db(7), minus22p5db(8)}read-writemandatory
portT1AdminRowStatus
OBJECT-TYPE
1.3.6.1.4.1.173.7.3.7.1.1.7RowStatusread-writemandatory
portT1AdminProtocolFraming
OBJECT-TYPE
1.3.6.1.4.1.173.7.3.7.1.1.8INTEGER {sync(1), bisync(2)}read-writemandatory
portT1AdminNRZI
OBJECT-TYPE
1.3.6.1.4.1.173.7.3.7.1.1.9INTEGER {no(1), yes(2)}read-writemandatory
portT1OperTable
OBJECT-TYPE
The configuration information pertaining to a T1 port. T1 ports can operate at full T1 bandwidth or DS0A channelized which provides 24 separate channels.
1.3.6.1.4.1.173.7.3.7.2not-accessiblemandatory
portT1OperEntry
OBJECT-TYPE
A T1 port entry containing objects relating to T1 ports.
1.3.6.1.4.1.173.7.3.7.2.1not-accessiblemandatory
portT1OperBlockedPortFlag
OBJECT-TYPE
1.3.6.1.4.1.173.7.3.7.2.1.1INTEGER {no(1), yes(2)}read-onlymandatory
portT1OperGenerateClock
OBJECT-TYPE
1.3.6.1.4.1.173.7.3.7.2.1.2INTEGER {no(1), yes(2)}read-onlymandatory
portT1OperFramingMode
OBJECT-TYPE
Specifies how this T1 port is to function. ds0AT1 specifies a 24 channelized T1.
1.3.6.1.4.1.173.7.3.7.2.1.3INTEGER {fullT1(1), ds0aT1(2)}read-onlymandatory
portT1OperFrameModelSelect
OBJECT-TYPE
1.3.6.1.4.1.173.7.3.7.2.1.4INTEGER {d4(1), esf(2)}read-onlymandatory
portT1OperLineEncoding
OBJECT-TYPE
1.3.6.1.4.1.173.7.3.7.2.1.5INTEGER {b8zs(1), ami(2)}read-onlymandatory
portT1OperLineBuildOut
OBJECT-TYPE
1.3.6.1.4.1.173.7.3.7.2.1.6INTEGER {zerodb(1), x133-266ft(2), x266-399ft(3), x399-533ft(4), x533-655ft(5), minus7p5db(6), minus15db(7), minus22p5db(8)}read-onlymandatory
portT1OperProtocolFraming
OBJECT-TYPE
1.3.6.1.4.1.173.7.3.7.2.1.7INTEGER {sync(1), bisync(2)}read-onlymandatory
portT1OperNRZI
OBJECT-TYPE
1.3.6.1.4.1.173.7.3.7.2.1.8INTEGER {no(1), yes(2)}read-onlymandatory
portVoiceGroup
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.3.8
portVoiceAdminTable
OBJECT-TYPE
A list of Voice ports. The number of entries will be the number of Voice ports on the node.
1.3.6.1.4.1.173.7.3.8.1not-accessiblemandatory
portVoiceAdminEntry
OBJECT-TYPE
A Voice Port entry containing objects relating to the port that are configurable by the user.
1.3.6.1.4.1.173.7.3.8.1.1not-accessiblemandatory
portVoiceAdminRlpIndex
OBJECT-TYPE
The RLP number of the Voice port.
1.3.6.1.4.1.173.7.3.8.1.1.1INTEGERread-onlymandatory
portVoiceAdminPortIndex
OBJECT-TYPE
The Port number of the Voice port.
1.3.6.1.4.1.173.7.3.8.1.1.2INTEGERread-onlymandatory
portVoiceAdminBlockedFlag
OBJECT-TYPE
The flag which causes the port to be enabled or disabled at node IPL. The port will remain in that state until this flag is changed and the node is rebooted, or until an on- line enable or disable is performed.
1.3.6.1.4.1.173.7.3.8.1.1.3INTEGER {disabled(1), enabled(2)}read-writemandatory
portVoiceAdminSpeed
OBJECT-TYPE
The speed of the port which is transmitted as part of a Call Setup frame. A Voice call will be established if there is enough bandwidth at each end to provide the minimum configured rate.
1.3.6.1.4.1.173.7.3.8.1.1.4INTEGER {bps-4800(1), bps-8000(2), bps-32000(3), bps-64000(4)}read-writemandatory
portVoiceAdminDTMF
OBJECT-TYPE
The flag to enable, disable, or specify a time span over which DTMF (Dual Tone Multi Frequency) tones will be regenerated. 0 = pass tones transparently to the remote device. 1 = detect incoming tones and regenerate as received. 2-255 = regenerate tones for the specified seconds.
1.3.6.1.4.1.173.7.3.8.1.1.5INTEGER (0..255)read-writemandatory
portVoiceAdminInterface
OBJECT-TYPE
The type of interface (in conjunction with the Telephony Interface Type) that will be used by the Voice channel. This requires rebooting for the change to take effect. Telephony Type Interface Type -------------- -------------- OPX (FXO) Loop Start SLT (FXS) Loop Start E&M 4W E&M, 4W E&M TE, 2W E&M, 2W E&M TE AC15 AC15A, AC15C
1.3.6.1.4.1.173.7.3.8.1.1.6INTEGER {em-4w(1), em-2w(2), loop-start(3), ac15-a(4), ac15-b(6), em-4w-te(10), em-2w-te(11)}read-writemandatory
portVoiceAdminTETimer
OBJECT-TYPE
The delay at which the E&M 'E' lead follows the 'M' lead.
1.3.6.1.4.1.173.7.3.8.1.1.7INTEGER (0..255)read-writemandatory
portVoiceAdminLevelIn
OBJECT-TYPE
The local voice level into the voice port. This adjusts the sensitivity of the local voice channel to the signal from the attached device. The purpose of this is to match the voice channel dB level to the input signal. A more negative setting produces a higher input gain. If the level is reduced, the voice channel will be more sensitive to the input. This will also cause the voice output at the remote device to sound louder.
1.3.6.1.4.1.173.7.3.8.1.1.8INTEGER (-22..7)read-writemandatory
portVoiceAdminLevelOut
OBJECT-TYPE
The local voice level out of the voice port. A more positive setting produces a higher volume.
1.3.6.1.4.1.173.7.3.8.1.1.9INTEGER (-22..7)read-writemandatory
portVoiceAdminCallTimer
OBJECT-TYPE
The amount of time the node will wait for a response to a Call Connect or Call Clear request. When the node issues a request, it will set a timer to the value configured here. If that timer expires with no response from the destination, the node will generate a busy tone.
1.3.6.1.4.1.173.7.3.8.1.1.10INTEGER (1..30)read-writemandatory
portVoiceAdminHuntGroup
OBJECT-TYPE
The hunt group that includes the voice channel.
1.3.6.1.4.1.173.7.3.8.1.1.11INTEGER {none(1), a(2), b(3)}read-writemandatory
portVoiceAdminLongDialPrefix
OBJECT-TYPE
The character that will be required preceeding calls using the long call format. When the user at an attached device dials a long form number, it must be preceeded by the prefix character specified here.
1.3.6.1.4.1.173.7.3.8.1.1.12OCTET STRING (SIZE(1))read-writemandatory
portVoiceAdminSLTTimeout
OBJECT-TYPE
The time the local port will wait before an actual fax transmission begins. If there is no fax tone when this timer expires, the connection will be terminated.
1.3.6.1.4.1.173.7.3.8.1.1.13INTEGER (1..99)read-writemandatory
portVoiceAdminLinkDownBusy
OBJECT-TYPE
This flag enables or disables automatic busy-out of channels when the link is down. When enabled, the system will automatically busy-out channels when the composite link is down. When disabled, channels remain on-hook when the link is down. If your application is connected to a PBX that can route calls to another alternate source based on an all busy condition, enable this so the PBX will recognize this condition and reroute the calls while the composite link is down.
1.3.6.1.4.1.173.7.3.8.1.1.14INTEGER {disabled(1), enabled(2)}read-writemandatory
portVoiceAdminFaxSupported
OBJECT-TYPE
The flag to indicate whether or not faxes will be transmitted on the port. If no, all calls will be treated as voice. If yes, both voice and fax will be transmitted.
1.3.6.1.4.1.173.7.3.8.1.1.15INTEGER {no(1), yes(2)}read-writemandatory
portVoiceAdminTelephonyType
OBJECT-TYPE
The type of interface (in conjunction with the Interface Type) that will be used by the Voice channel. This requires rebooting for the change to take effect. Telephony Type Interface Type -------------- -------------- OPX (FXO) Loop Start SLT (FXS) Loop Start E&M 4W E&M, 4W E&M TE, 2W E&M, 2W E&M TE AC15 AC15A, AC15C
1.3.6.1.4.1.173.7.3.8.1.1.16INTEGER {opx(1), slt(2), em(3), ac15(4)}read-writemandatory
portVoiceAdminJitter
OBJECT-TYPE
The amount of jitter delay.
1.3.6.1.4.1.173.7.3.8.1.1.17INTEGER (10..255)read-writemandatory
portVoiceAdminSampleDelay
OBJECT-TYPE
The amount of sample delay.
1.3.6.1.4.1.173.7.3.8.1.1.18INTEGER (0..255)read-writemandatory
portVoiceAdminDialTimer
OBJECT-TYPE
The delay the node will use to determine when variable length dialing is complete. (Variable length dialing allows the user to place a call without entering the configured number of digits for the speed dial number.)
1.3.6.1.4.1.173.7.3.8.1.1.19INTEGER (0..10)read-writemandatory
portVoiceAdminAutoDial
OBJECT-TYPE
The flag to enable or disable the auto dial feature. Note that enabling this feature will disable the variable length dialing feature for this channel.
1.3.6.1.4.1.173.7.3.8.1.1.20INTEGER {disabled(1), enabled(2)}read-writemandatory
portVoiceAdminSuppression
OBJECT-TYPE
The silence suppression level. A larger silence suppression level allows more data channels to operate simultaneously with the voice channels.
1.3.6.1.4.1.173.7.3.8.1.1.21INTEGER {very-low(1), low(2), medium(3), high(4), very-high(5)}read-writemandatory
portVoiceAdminAutoDialNumber
OBJECT-TYPE
The number to which the node will attempt to connect when the handset attached to this port is taken off-hook. This is applicable only when the Auto Dial feature is enabled.
1.3.6.1.4.1.173.7.3.8.1.1.22OCTET STRING (SIZE(0..4))read-writemandatory
portVoiceAdminAutoPoll
OBJECT-TYPE
The flag to enable or disable auto polling. This is applicable only when the Auto Dial feature is enabled. When enabled, the node periodically polls the destination. If the poll is not acknowledged, the node will busy-out the channel. This can be useful in situations where the destination is an emergency number that must always be available. If the destination does not answer the automatic poll, the busy-out condition will notify an attached PBX that the emergency call should be routed to another call routing device.
1.3.6.1.4.1.173.7.3.8.1.1.23INTEGER {disabled(1), enabled(2)}read-writemandatory
portVoiceAdminAutoPollTimer
OBJECT-TYPE
The frequency with which an Auto Poll will be sent. This is applicable only when auto poll is enabled.
1.3.6.1.4.1.173.7.3.8.1.1.24INTEGER (5..30)read-writemandatory
portVoiceAdminExtDigitsSource
OBJECT-TYPE
The source of the extended digits when the user of attached equipment dials a speed dial number. This is applicable only when the number of extended dial digits is greater than zero. When map is specified, extended digits are taken from the extended digits field in the map table. When user is specified, extended digits are taken from the user of attached equipment.
1.3.6.1.4.1.173.7.3.8.1.1.25INTEGER {map(1), user(2)}read-writemandatory
portVoiceAdminNumDigitsDelete
OBJECT-TYPE
The number of leading dial digits that will be deleted before a dial string is forwarded. This is primarily used to delete leading dial digits that may be inserted by an attached PBX.
1.3.6.1.4.1.173.7.3.8.1.1.26INTEGER (0..4)read-writemandatory
portVoiceAdminForwardDelay
OBJECT-TYPE
The length of a pause that can be inserted in an extended dial string that is being forwarded. This is applicable only when forwarded output digits is all or extended. When a comma is encountered in an extended digits string, the node will pause for the length of time specified here before additional extended digits are forwarded.
1.3.6.1.4.1.173.7.3.8.1.1.27INTEGER (0..40)read-writemandatory
portVoiceAdminForwardedType
OBJECT-TYPE
The method how the dial digits will be forwarded. This is applicable only when forwarded output digits is all or extended.
1.3.6.1.4.1.173.7.3.8.1.1.28INTEGER {dtmf(1), pulse(2)}read-writemandatory
portVoiceAdminForwardedDigits
OBJECT-TYPE
The flag indicating which dial digits, if any, to forward. If none, dial digits are not forwarded to the destination device when a call is initiated on this channel. If all, the dialed speed dial number and associated extended digits are forwarded to the destination device. If extended, only the extended digit string is forwarded.
1.3.6.1.4.1.173.7.3.8.1.1.29INTEGER {none(1), all(2), extended(3)}read-writemandatory
portVoiceAdminMakeRatio
OBJECT-TYPE
The make ratio of each digit pulse that is forwarded. This is applicable only when forwarded output digits is all or extended and forwarded digit type is pulse.
1.3.6.1.4.1.173.7.3.8.1.1.30INTEGER (20..80)read-writemandatory
portVoiceAdminBreakRatio
OBJECT-TYPE
The break ratio of each digit pulse that is forwarded. This is applicable only when forwarded output digits is all or extended and forwarded digit type is pulse.
1.3.6.1.4.1.173.7.3.8.1.1.31INTEGER (20..80)read-writemandatory
portVoiceAdminDTMFOnDuration
OBJECT-TYPE
The length of a tone that will be used to produce a single DTMF digit. This is applicable only when forwarded output digits is all or extended and forwarded digit type is DTMF.
1.3.6.1.4.1.173.7.3.8.1.1.32INTEGER (30..1000)read-writemandatory
portVoiceAdminDTMFOffDuration
OBJECT-TYPE
The length of silence between DTMF tones in a dial digit string. This is applicable only when forwarded output digits is all or extended and forwarded digit type is DTMF.
1.3.6.1.4.1.173.7.3.8.1.1.33INTEGER (30..1000)read-writemandatory
portVoiceAdminToneType
OBJECT-TYPE
The tone type to detect/regenerate for forwarding DTMF/MF.
1.3.6.1.4.1.173.7.3.8.1.1.34INTEGER {dtmf(1), mf(2)}read-writemandatory
portVoiceAdminRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the portVoiceAdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device, and which is supplied by a management station wishing to exercise an on-line update of the existing conceptual row. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.3.8.1.1.35RowStatusread-writemandatory
portVoiceOperTable
OBJECT-TYPE
A list of Voice ports. The number of entries will be the number of Voice ports on the node.
1.3.6.1.4.1.173.7.3.8.2not-accessiblemandatory
portVoiceOperEntry
OBJECT-TYPE
A Voice Port entry containing objects relating to the port that are configurable by the user.
1.3.6.1.4.1.173.7.3.8.2.1not-accessiblemandatory
portVoiceOperRlpIndex
OBJECT-TYPE
The RLP number of the Voice port.
1.3.6.1.4.1.173.7.3.8.2.1.1INTEGERread-onlymandatory
portVoiceOperPortIndex
OBJECT-TYPE
The Port number of the Voice port.
1.3.6.1.4.1.173.7.3.8.2.1.2INTEGERread-onlymandatory
portVoiceOperBlockedFlag
OBJECT-TYPE
The flag which causes the port to be enabled or disabled at node IPL. The port will remain in that state until this flag is changed and the node is rebooted, or until an on- line enable or disable is performed.
1.3.6.1.4.1.173.7.3.8.2.1.3INTEGER {disabled(1), enabled(2)}read-onlymandatory
portVoiceOperSpeed
OBJECT-TYPE
The speed of the port which is transmitted as part of a Call Setup frame. A Voice call will be established if there is enough bandwidth at each end to provide the minimum configured rate.
1.3.6.1.4.1.173.7.3.8.2.1.4INTEGER {bps-4800(1), bps-8000(2), bps-32000(3), bps-64000(4)}read-onlymandatory
portVoiceOperDTMF
OBJECT-TYPE
The flag to enable, disable, or specify a time span over which DTMF (Dual Tone Multi Frequency) tones will be regenerated. 0 = pass tones transparently to the remote device. 1 = detect incoming tones and regenerate as received. 2-255 = regenerate tones for the specified seconds.
1.3.6.1.4.1.173.7.3.8.2.1.5INTEGER (0..255)read-onlymandatory
portVoiceOperInterface
OBJECT-TYPE
The type of interface (in conjunction with the Telephony Interface Type) that will be used by the Voice channel. This requires rebooting for the change to take effect. Telephony Type Interface Type -------------- -------------- OPX (FXO) Loop Start SLT (FXS) Loop Start E&M 4W E&M, 4W E&M TE, 2W E&M, 2W E&M TE AC15 AC15A, AC15C
1.3.6.1.4.1.173.7.3.8.2.1.6INTEGER {em-4w(1), em-2w(2), loop-start(3), ac15-a(4), ac15-b(6), em-4w-te(10), em-2w-te(11)}read-onlymandatory
portVoiceOperTETimer
OBJECT-TYPE
The delay at which the E&M 'E' lead follows the 'M' lead.
1.3.6.1.4.1.173.7.3.8.2.1.7INTEGER (0..255)read-onlymandatory
portVoiceOperLevelIn
OBJECT-TYPE
The local voice level into the voice port. This adjusts the sensitivity of the local voice channel to the signal from the attached device. The purpose of this is to match the voice channel dB level to the input signal. A more negative setting produces a higher input gain. If the level is reduced, the voice channel will be more sensitive to the input. This will also cause the voice output at the remote device to sound louder.
1.3.6.1.4.1.173.7.3.8.2.1.8INTEGER (-22..7)read-onlymandatory
portVoiceOperLevelOut
OBJECT-TYPE
The local voice level out of the voice port. A more positive setting produces a higher volume.
1.3.6.1.4.1.173.7.3.8.2.1.9INTEGER (-22..7)read-onlymandatory
portVoiceOperCallTimer
OBJECT-TYPE
The amount of time the node will wait for a response to a Call Connect or Call Clear request. When the node issues a request, it will set a timer to the value configured here. If that timer expires with no response from the destination, the node will generate a busy tone.
1.3.6.1.4.1.173.7.3.8.2.1.10INTEGER (1..30)read-onlymandatory
portVoiceOperHuntGroup
OBJECT-TYPE
The hunt group that includes the voice channel.
1.3.6.1.4.1.173.7.3.8.2.1.11INTEGER {none(1), a(2), b(3)}read-onlymandatory
portVoiceOperLongDialPrefix
OBJECT-TYPE
The character that will be required preceeding calls using the long call format. When the user at an attached device dials a long form number, it must be preceeded by the prefix character specified here.
1.3.6.1.4.1.173.7.3.8.2.1.12OCTET STRING (SIZE(1))read-onlymandatory
portVoiceOperSLTTimeout
OBJECT-TYPE
The time the local port will wait before an actual fax transmission begins. If there is no fax tone when this timer expires, the connection will be terminated.
1.3.6.1.4.1.173.7.3.8.2.1.13INTEGER (1..99)read-onlymandatory
portVoiceOperLinkDownBusy
OBJECT-TYPE
This flag enables or disables automatic busy-out of channels when the link is down. When enabled, the system will automatically busy-out channels when the composite link is down. When disabled, channels remain on-hook when the link is down. If your application is connected to a PBX that can route calls to another alternate source based on an all busy condition, enable this so the PBX will recognize this condition and reroute the calls while the composite link is down.
1.3.6.1.4.1.173.7.3.8.2.1.14INTEGER {disabled(1), enabled(2)}read-onlymandatory
portVoiceOperFaxSupported
OBJECT-TYPE
The flag to indicate whether or not faxes will be transmitted on the port. If no, all calls will be treated as voice. If yes, both voice and fax will be transmitted.
1.3.6.1.4.1.173.7.3.8.2.1.15INTEGER {no(1), yes(2)}read-onlymandatory
portVoiceOperTelephonyType
OBJECT-TYPE
The type of interface (in conjunction with the Interface Type) that will be used by the Voice channel. This requires rebooting for the change to take effect. Telephony Type Interface Type -------------- -------------- OPX (FXO) Loop Start SLT (FXS) Loop Start E&M 4W E&M, 4W E&M TE, 2W E&M, 2W E&M TE AC15 AC15A, AC15C
1.3.6.1.4.1.173.7.3.8.2.1.16INTEGER {opx(1), slt(2), em(3), ac15(4)}read-onlymandatory
portVoiceOperJitter
OBJECT-TYPE
The amount of jitter delay.
1.3.6.1.4.1.173.7.3.8.2.1.17INTEGER (10..255)read-onlymandatory
portVoiceOperSampleDelay
OBJECT-TYPE
The amount of sample delay.
1.3.6.1.4.1.173.7.3.8.2.1.18INTEGER (0..255)read-onlymandatory
portVoiceOperDialTimer
OBJECT-TYPE
The delay the node will use to determine when variable length dialing is complete. (Variable length dialing allows the user to place a call without entering the configured number of digits for the speed dial number.)
1.3.6.1.4.1.173.7.3.8.2.1.19INTEGER (0..10)read-onlymandatory
portVoiceOperAutoDial
OBJECT-TYPE
The flag to enable or disable the auto dial feature. Note that enabling this feature will disable the variable length dialing feature for this channel.
1.3.6.1.4.1.173.7.3.8.2.1.20INTEGER {disabled(1), enabled(2)}read-onlymandatory
portVoiceOperSuppression
OBJECT-TYPE
The silence suppression level. A larger silence suppression level allows more data channels to operate simultaneously with the voice channels.
1.3.6.1.4.1.173.7.3.8.2.1.21INTEGER {very-low(1), low(2), medium(3), high(4), very-high(5)}read-onlymandatory
portVoiceOperAutoDialNumber
OBJECT-TYPE
The number to which the node will attempt to connect when the handset attached to this port is taken off-hook. This is applicable only when the Auto Dial feature is enabled.
1.3.6.1.4.1.173.7.3.8.2.1.22OCTET STRING (SIZE(0..4))read-onlymandatory
portVoiceOperAutoPoll
OBJECT-TYPE
The flag to enable or disable auto polling. This is applicable only when the Auto Dial feature is enabled. When enabled, the node periodically polls the destination. If the poll is not acknowledged, the node will busy-out the channel. This can be useful in situations where the destination is an emergency number that must always be available. If the destination does not answer the automatic poll, the busy-out condition will notify an attached PBX that the emergency call should be routed to another call routing device.
1.3.6.1.4.1.173.7.3.8.2.1.23INTEGER {disabled(1), enabled(2)}read-onlymandatory
portVoiceOperAutoPollTimer
OBJECT-TYPE
The frequency with which an Auto Poll will be sent. This is applicable only when auto poll is enabled.
1.3.6.1.4.1.173.7.3.8.2.1.24INTEGER (5..30)read-onlymandatory
portVoiceOperExtDigitsSource
OBJECT-TYPE
The source of the extended digits when the user of attached equipment dials a speed dial number. This is applicable only when the number of extended dial digits is greater than zero. When map is specified, extended digits are taken from the extended digits field in the map table. When user is specified, extended digits are taken from the user of attached equipment.
1.3.6.1.4.1.173.7.3.8.2.1.25INTEGER {map(1), user(2)}read-onlymandatory
portVoiceOperNumDigitsDelete
OBJECT-TYPE
The number of leading dial digits that will be deleted before a dial string is forwarded. This is primarily used to delete leading dial digits that may be inserted by an attached PBX.
1.3.6.1.4.1.173.7.3.8.2.1.26INTEGER (0..4)read-onlymandatory
portVoiceOperForwardDelay
OBJECT-TYPE
The length of a pause that can be inserted in an extended dial string that is being forwarded. This is applicable only when forwarded output digits is all or extended. When a comma is encountered in an extended digits string, the node will pause for the length of time specified here before additional extended digits are forwarded.
1.3.6.1.4.1.173.7.3.8.2.1.27INTEGER (0..40)read-onlymandatory
portVoiceOperForwardedType
OBJECT-TYPE
The method how the dial digits will be forwarded. This is applicable only when forwarded output digits is all or extended.
1.3.6.1.4.1.173.7.3.8.2.1.28INTEGER {dtmf(1), pulse(2)}read-onlymandatory
portVoiceOperForwardedDigits
OBJECT-TYPE
The flag indicating which dial digits, if any, to forward. If none, dial digits are not forwarded to the destination device when a call is initiated on this channel. If all, the dialed speed dial number and associated extended digits are forwarded to the destination device. If extended, only the extended digit string is forwarded.
1.3.6.1.4.1.173.7.3.8.2.1.29INTEGER {none(1), all(2), extended(3)}read-onlymandatory
portVoiceOperMakeRatio
OBJECT-TYPE
The make ratio of each digit pulse that is forwarded. This is applicable only when forwarded output digits is all or extended and forwarded digit type is pulse.
1.3.6.1.4.1.173.7.3.8.2.1.30INTEGER (20..80)read-onlymandatory
portVoiceOperBreakRatio
OBJECT-TYPE
The break ratio of each digit pulse that is forwarded. This is applicable only when forwarded output digits is all or extended and forwarded digit type is pulse.
1.3.6.1.4.1.173.7.3.8.2.1.31INTEGER (20..80)read-onlymandatory
portVoiceOperDTMFOnDuration
OBJECT-TYPE
The length of a tone that will be used to produce a single DTMF digit. This is applicable only when forwarded output digits is all or extended and forwarded digit type is DTMF.
1.3.6.1.4.1.173.7.3.8.2.1.32INTEGER (30..1000)read-onlymandatory
portVoiceOperDTMFOffDuration
OBJECT-TYPE
The length of silence between DTMF tones in a dial digit string. This is applicable only when forwarded output digits is all or extended and forwarded digit type is DTMF.
1.3.6.1.4.1.173.7.3.8.2.1.33INTEGER (30..1000)read-onlymandatory
portVoiceOperToneType
OBJECT-TYPE
The tone type to detect/regenerate for forwarding DTMF/MF.
1.3.6.1.4.1.173.7.3.8.2.1.34INTEGER {dtmf(1), mf(2)}read-onlymandatory
nlInterfaces
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.4
nlIfTable
OBJECT-TYPE
A Table to describe each interface on a node. This table is indexed by RLP and Port number and can be used to identify the corresponding MIB-II ifIndex of a Port as well as additional port information maintained by Netlink.
1.3.6.1.4.1.173.7.4.1not-accessiblemandatory
nlIfEntry
OBJECT-TYPE
An Interface entry containing objects relating to interfaces.
1.3.6.1.4.1.173.7.4.1.1not-accessiblemandatory
nlIfRlp
OBJECT-TYPE
The RLP number on the node. RLP numbers 1-8 are Physical RLP cards, and RLP number 250, 251 and 252 define IP, IPX and LLC2 interfaces respectively.
1.3.6.1.4.1.173.7.4.1.1.1INTEGERread-onlymandatory
nlIfPort
OBJECT-TYPE
The Port number on the RLP. Port numbers 1-8 are known to be physical ports, and 9-64 are logical ports. If the RLP number identifies an IP, IPX or LLC2 interface, then the port number can be 1-257 (IP), 1-64 (IPX), or 1-96 (LLC2).
1.3.6.1.4.1.173.7.4.1.1.2INTEGERread-onlymandatory
nlIfType
OBJECT-TYPE
The type of interface
1.3.6.1.4.1.173.7.4.1.1.3INTEGER {other(1), regular1822(2), hdh1822(3), ddnX25(4), rfc877x25(5), ethernetCsmacd(6), iso88023Csmacd(7), iso88024TokenBus(8), iso88025TokenRing(9), iso88026Man(10), starLan(11), proteon10Mbit(12), proteon80Mbit(13), hyperchannel(14), fddi(15), lapb(16), sdlc(17), ds1(18), e1(19), basicISDN(20), primaryISDN(21), propPointToPointSerial(22), ppp(23), softwareLoopback(24), eon(25), ethernet3Mbit(26), nsip(27), slip(28), ultra(29), ds3(30), sip(31), frameRelay(32), rs232(33), para(34), arcnet(35), arcnetPlus(36), atm(37), miox25(38), sonet(39), x25ple(40), iso88022llc(41), localTalk(42), smdsDxi(43), frameRelayService(44), v35(45), hssi(46), hippi(47), modem(48), aal5(49), sonetPath(50), sonetVT(51), smdsIcip(52), propVirtual(53), propMultiplexor(54), trunk(200), async(201), bsci(202), logicalPort(203), t1(204), ip(205), ipx(206), llc2(207), voice(208)}read-onlymandatory
nlIfIndex
OBJECT-TYPE
The associated index into the MIB-II ifTable for this port
1.3.6.1.4.1.173.7.4.1.1.4INTEGERread-onlymandatory
nlIfTableIndex
OBJECT-TYPE
The associated index into an enterprise table used to describe additional information for this port. See nlIfTableOid as the pointer to the actual table.
1.3.6.1.4.1.173.7.4.1.1.5INTEGERread-onlymandatory
nlIfTableOid
OBJECT-TYPE
The OID of the table Entry that contains additional information about this port. The OID will point to a specific table depending on the type of port.
1.3.6.1.4.1.173.7.4.1.1.6OBJECT IDENTIFIERread-onlymandatory
nlIfConnectorType
OBJECT-TYPE
The physical connector type used for this port. Valid for ports 1-8 only.
1.3.6.1.4.1.173.7.4.1.1.7INTEGER {none(2), rs232(3), v25bis-dial(4), v35(5), rs449(6), rs530(7), x21(8), csudsu(9), t1(10), e1(11), voice(13)}read-onlymandatory
nlIfPortStatus
OBJECT-TYPE
The status of this port state. Valid for ports 1-64 only.
1.3.6.1.4.1.173.7.4.1.1.8INTEGER {linkUp(1), restarting(2), operational(3), disabled(4), disconnect(5), configured(6), dialReady(7), quiesced(8), failed(9), hardwareFault(10), other(11), ipl(12), na(13), remoteLoopback(14), blueAlarm(15), yellowAlarm(16), redAlarm(17), onHook(18), offHook(19), dialing(20), activeVoiceCall(21), onHookPending(22)}read-onlymandatory
nlIfPhyPort
OBJECT-TYPE
The Underlying Physical Port number on the RLP of this logical port. Port numbers 1-8 are valid, but this field is only applicable if the nlIfPort field is 9-64.
1.3.6.1.4.1.173.7.4.1.1.9INTEGERread-onlymandatory
nlIfLlc2Interfaces
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.4.2
nlIfLlc2LANTable
OBJECT-TYPE
A Table to define LLC2 interfaces over LAN.
1.3.6.1.4.1.173.7.4.2.1not-accessiblemandatory
nlIfLlc2LANEntry
OBJECT-TYPE
An LLC2 LAN Interface entry containing objects relating to LLC2 LAN interfaces.
1.3.6.1.4.1.173.7.4.2.1.1not-accessiblemandatory
nlIfLlc2LANRlp
OBJECT-TYPE
The RLP number on the node. For LLC2 LAN interfaces, this must be 252.
1.3.6.1.4.1.173.7.4.2.1.1.1INTEGERread-onlymandatory
nlIfLlc2LANPort
OBJECT-TYPE
The Port number on the RLP. For LLC2 LAN interfaces, this corresponds to the LAN card number.
1.3.6.1.4.1.173.7.4.2.1.1.2INTEGERread-onlymandatory
nlIfLlc2LANType
OBJECT-TYPE
The type of the LLC2 interface- either ethernet or token ring.
1.3.6.1.4.1.173.7.4.2.1.1.3INTEGER {ethernet(1), token-ring(2)}read-writemandatory
nlIfLlc2LANCard
OBJECT-TYPE
The LAN card that the LLC2 interface is running on.
1.3.6.1.4.1.173.7.4.2.1.1.4INTEGER (1..2)read-onlymandatory
nlIfLlc2LANID
OBJECT-TYPE
Valid only if the type of the LLC2 LAN interface is token ring. Identifies the token ring adapter to the network.
1.3.6.1.4.1.173.7.4.2.1.1.5INTEGER (0..4095)read-writemandatory
nlIfLlc2LANInterface
OBJECT-TYPE
The LLC2 interface number.
1.3.6.1.4.1.173.7.4.2.1.1.6INTEGER (1..2)read-onlymandatory
nlIfLlc2LANRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the nlIfLlc2LANTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.4.2.1.1.7RowStatusread-writemandatory
nlIfLlc2LANPriority
OBJECT-TYPE
Interface priority- allows setting a priority for traffic within the node. The higher the number, the higher the priority relative to other intra-nodal traffic.
1.3.6.1.4.1.173.7.4.2.1.1.8INTEGER (0..9)read-writemandatory
nlIfLlc2LANBlockedPortFlag
OBJECT-TYPE
The blocked port flag.
1.3.6.1.4.1.173.7.4.2.1.1.9INTEGER {no(1), yes(2)}read-writemandatory
nlIfLlc2FrTable
OBJECT-TYPE
A Table to define LLC2 interfaces over Frame Relay.
1.3.6.1.4.1.173.7.4.2.2not-accessiblemandatory
nlIfLlc2FrEntry
OBJECT-TYPE
An LLC2 FR Interface entry containing objects relating to LLC2 FR interfaces.
1.3.6.1.4.1.173.7.4.2.2.1not-accessiblemandatory
nlIfLlc2FrRlp
OBJECT-TYPE
The RLP number on the node.
1.3.6.1.4.1.173.7.4.2.2.1.1INTEGER (1..8)read-onlymandatory
nlIfLlc2FrPort
OBJECT-TYPE
The Port number on the RLP. Port numbers 1-8 are known to be physical ports, and channels are 193-241.
1.3.6.1.4.1.173.7.4.2.2.1.2INTEGER (1..255)read-onlymandatory
nlIfLlc2FrDLCI
OBJECT-TYPE
The DLCI number used to identify the entry in the table. The range is 16-991.
1.3.6.1.4.1.173.7.4.2.2.1.3INTEGER (16..991)read-onlymandatory
nlIfLlc2FrFormat
OBJECT-TYPE
The RFC1490 encapsulation method used for LLC2 traffic.
1.3.6.1.4.1.173.7.4.2.2.1.4INTEGER {native-llc2(1), tb-8023(2), srb-8025(3)}read-onlymandatory
nlIfLlc2FrPriority
OBJECT-TYPE
Interface priority- allows setting a priority for traffic within the node. The higher the number, the higher the priority relative to other intra-nodal traffic.
1.3.6.1.4.1.173.7.4.2.2.1.5INTEGER (0..9)read-writemandatory
nlIfLlc2FrBAG
OBJECT-TYPE
Assigns the interface to one of sixteen groups whose parameters regulate bandwidth usage.
1.3.6.1.4.1.173.7.4.2.2.1.6INTEGER (1..16)read-writemandatory
nlIfLlc2FrHostMACAddress
OBJECT-TYPE
The MAC address of the host or workstation to which the remote device needs to connect. Valid only if the format is native-llc2.
1.3.6.1.4.1.173.7.4.2.2.1.7MacAddressread-writemandatory
nlIfLlc2FrSessionType
OBJECT-TYPE
If originated, means that LLC2 connects from the configured Host MAC address can use this interface. If terminated, connections to the configured address can use this interface. Valid only if the format is native-llc2.
1.3.6.1.4.1.173.7.4.2.2.1.8INTEGER {terminated(1), originated(2), not-applicable(3)}read-writemandatory
nlIfLlc2FrLANID
OBJECT-TYPE
Identifies the ring number used by a frame relay-compliant source-route bridge at the other end of this PVC. Valid only if the format is srb-8025.
1.3.6.1.4.1.173.7.4.2.2.1.9INTEGER (0..4095)read-writemandatory
nlIfLlc2FrInterface
OBJECT-TYPE
LLC2 interface number.
1.3.6.1.4.1.173.7.4.2.2.1.10INTEGERread-onlymandatory
nlIfLlc2FrRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the nlIfLlc2FrTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.4.2.2.1.11RowStatusread-writemandatory
nlIfLlc2FrBlockedPortFlag
OBJECT-TYPE
The blocked port flag.
1.3.6.1.4.1.173.7.4.2.2.1.12INTEGER {no(1), yes(2)}read-writemandatory
ipxConfig
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.4.3
ipxConfigRouting
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.4.3.1
ipxStaticRouteConfigTable
OBJECT-TYPE
The IPX Static Route Configuration Table
1.3.6.1.4.1.173.7.4.3.1.1not-accessiblemandatory
ipxStaticRouteConfigEntry
OBJECT-TYPE
Each entry corresponds to one instance of IPX Static Routing on the system
1.3.6.1.4.1.173.7.4.3.1.1.1not-accessiblemandatory
ipxStaticRouteConfigCircIndex
OBJECT-TYPE
The unique identifier of the circuit used to reach the first hop in the static route
1.3.6.1.4.1.173.7.4.3.1.1.1.1INTEGER (1..65535)read-onlymandatory
ipxStaticRouteConfigNetNum
OBJECT-TYPE
The IPX network number of the route's destination
1.3.6.1.4.1.173.7.4.3.1.1.1.2OCTET STRING (SIZE(4))read-onlymandatory
ipxStaticRouteConfigRouter
OBJECT-TYPE
The hex value of the node address of the router that will forward a packet when this route is used. If Novell's IPXWAN is used on the interface, this field will be ignored
1.3.6.1.4.1.173.7.4.3.1.1.1.3OCTET STRING (SIZE(6))read-writemandatory
ipxStaticRouteConfigRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the ipxStaticRouteTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.4.3.1.1.1.4RowStatusread-writemandatory
ipxServConfigTable
OBJECT-TYPE
The IPX Static Route Configuration Table
1.3.6.1.4.1.173.7.4.3.1.2not-accessiblemandatory
ipxServConfigEntry
OBJECT-TYPE
Each entry corresponds to one instance of IPX Static Routing on the system
1.3.6.1.4.1.173.7.4.3.1.2.1not-accessiblemandatory
ipxServConfigServiceType
OBJECT-TYPE
The Service Type, a SAP service code
1.3.6.1.4.1.173.7.4.3.1.2.1.1INTEGER (1..65535)read-onlymandatory
ipxServConfigServName
OBJECT-TYPE
The Sercice Name, identifies a specific server in the IPX network.
1.3.6.1.4.1.173.7.4.3.1.2.1.2OCTET STRING (SIZE(1..48))read-onlymandatory
ipxServConfigServNetworkAddress
OBJECT-TYPE
The IPX network number portion of the IPX address of the server identified by ServName
1.3.6.1.4.1.173.7.4.3.1.2.1.3INTEGERread-writemandatory
ipxServConfigServNodeAddress
OBJECT-TYPE
The node portion of the IPX address of the service
1.3.6.1.4.1.173.7.4.3.1.2.1.4OCTET STRING (SIZE(6))read-writemandatory
ipxServConfigServSocketNumber
OBJECT-TYPE
The socket portion of the IPX address of the service
1.3.6.1.4.1.173.7.4.3.1.2.1.5INTEGER (0..65535)read-writemandatory
ipxServConfigInterveningNetworks
OBJECT-TYPE
The number of routers that a packet must pass through t reach the server
1.3.6.1.4.1.173.7.4.3.1.2.1.6INTEGER (1..65535)read-writemandatory
ipxServConfigGatewayAddress
OBJECT-TYPE
The node address of the router thar will forward a packet
1.3.6.1.4.1.173.7.4.3.1.2.1.7OCTET STRING (SIZE(6))read-writemandatory
ipxServConfigInterface
OBJECT-TYPE
The IPX network number assigned to the interface used to send packets that are destined for this server
1.3.6.1.4.1.173.7.4.3.1.2.1.8INTEGER (0..65535)read-writemandatory
ipxServConfigRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the ipxServTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.4.3.1.2.1.9RowStatusread-writemandatory
ipxConfigInterface
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.4.3.2
ipxInterfaceTable
OBJECT-TYPE
The IPX Interface Table
1.3.6.1.4.1.173.7.4.3.2.6not-accessiblemandatory
ipxInterfaceEntry
OBJECT-TYPE
1.3.6.1.4.1.173.7.4.3.2.6.1not-accessiblemandatory
ipxInterfaceNumber
OBJECT-TYPE
The Interface Number, a sequential number to identify the interface
1.3.6.1.4.1.173.7.4.3.2.6.1.1INTEGER (1..64)read-onlymandatory
ipxInterfaceBlockedPortFlag
OBJECT-TYPE
This flag causes the IPX interface to be enabled (N) or disabled (Y) at node IPL. The port will remain in that state until this parameter is changed
1.3.6.1.4.1.173.7.4.3.2.6.1.2INTEGER {no(1), yes(2)}read-writemandatory
ipxInterfaceType
OBJECT-TYPE
The interface type. 802.5 is not valid on FRX4000
1.3.6.1.4.1.173.7.4.3.2.6.1.3INTEGER {ethernet(1), eight025(2), x25(3), frl(4)}read-writemandatory
ipxInterfaceFrameType
OBJECT-TYPE
The frame type - depends on the interfece type. Valid combinations are: Ethernet, 802.5 - typeII, raw, llc, snap Frame relay, X25 - typeII
1.3.6.1.4.1.173.7.4.3.2.6.1.4INTEGER {typeII(1), raw(2), llc(3), snap(4)}read-writemandatory
ipxInterfaceMaxTransUnit
OBJECT-TYPE
Maximum frame size that can be transmitted or received over the IPX interface.: Valid ranges are: Ethernet - (45-1518) 802.5 - (48-4096) Frame relay, X25 - (31-4096)
1.3.6.1.4.1.173.7.4.3.2.6.1.5INTEGERread-writemandatory
ipxInterfaceNetworkAddress
OBJECT-TYPE
Identifies the local interface to the Novell Network
1.3.6.1.4.1.173.7.4.3.2.6.1.6INTEGERread-writemandatory
ipxInterfaceBandwidthAllocGroup
OBJECT-TYPE
Assigns the IPX interface to one of sixteen groups whose parameters regulate bandwidth usage
1.3.6.1.4.1.173.7.4.3.2.6.1.7INTEGER (1..16)read-writemandatory
ipxInterfacePortDiagEnabled
OBJECT-TYPE
Enables/Disables the IPX interface's ability to handle Novell diagonistics packets
1.3.6.1.4.1.173.7.4.3.2.6.1.8INTEGER {no(1), yes(2)}read-writemandatory
ipxInterfaceNetBIOSEnabled
OBJECT-TYPE
Determines whether Novell-encapsulated NetBIOS frames received on the interface will be processed
1.3.6.1.4.1.173.7.4.3.2.6.1.9INTEGER {no(1), yes(2)}read-writemandatory
ipxInterfaceNetBIOSHops
OBJECT-TYPE
Maximum number of hops allowed for routing a Novell-encapsulated NetBIOS frame
1.3.6.1.4.1.173.7.4.3.2.6.1.10INTEGER (0..255)read-writemandatory
ipxInterfacePeriodicRIPEnabled
OBJECT-TYPE
Determines whether the node will originate periodic IPX Routing Information Protocol messages from this interface to inform the network that the route through this interface is viable
1.3.6.1.4.1.173.7.4.3.2.6.1.11INTEGER {no(1), yes(2)}read-writemandatory
ipxInterfacePeriodicRIPTimer
OBJECT-TYPE
This is the interval between the periodic IPX RIP broadcasts from this interface
1.3.6.1.4.1.173.7.4.3.2.6.1.12INTEGER (1..65535)read-writemandatory
ipxInterfacePeriodicSAPEnabled
OBJECT-TYPE
Determines whether the node will originate periodic IPX SAP messages from this interface to inform the network which SAP entries in the routing table are viable
1.3.6.1.4.1.173.7.4.3.2.6.1.13INTEGER {no(1), yes(2)}read-writemandatory
ipxInterfacePeriodicSAPTimer
OBJECT-TYPE
The interval between the periodic SAP broadcasts from this interface
1.3.6.1.4.1.173.7.4.3.2.6.1.14INTEGER (1..65535)read-writemandatory
ipxInterfaceRIPEnabled
OBJECT-TYPE
Datermines whether this interface will support RIP proceswsing
1.3.6.1.4.1.173.7.4.3.2.6.1.15INTEGER {no(1), yes(2)}read-writemandatory
ipxInterfaceRIPAgeTimer
OBJECT-TYPE
This is used to delete route entries in the routing information table. The timer starts/restarts each time an entry is created/updated. If the timer expires, the router will assume that the entry is no longer valid and the entry will be deleteda from the table
1.3.6.1.4.1.173.7.4.3.2.6.1.16INTEGER (0..65535)read-writemandatory
ipxInterfaceRIPMaxSize
OBJECT-TYPE
Maximum possible RIP packet size
1.3.6.1.4.1.173.7.4.3.2.6.1.17INTEGER (54..446)read-writemandatory
ipxInterfaceSAPEnabled
OBJECT-TYPE
Determines whether the interface will support SAP or not
1.3.6.1.4.1.173.7.4.3.2.6.1.18INTEGER {no(1), yes(2)}read-writemandatory
ipxInterfaceSAPAgeTimer
OBJECT-TYPE
This is used to delete route entries from the router information table. The timer starts/restars each time an entry is created/updated. If the timer expires, the router will assume that the entry is no longer valid and the entry will be deleted from the table
1.3.6.1.4.1.173.7.4.3.2.6.1.19INTEGER (0..65535)read-writemandatory
ipxInterfaceTransportTime
OBJECT-TYPE
is the time (in 55 milliseconds unit) that will normally take to forward frames out of interface. Recommmended values are 1 for LAN interfaces and 30 for WAN interfaces. A value of 0 indicates that the back to back frame forwarding is acceptable. This time is used to calculate the least cost path during routing. If IPXWAMN is (Y), Transport time will be overridden by the value calculated by IPXWAN
1.3.6.1.4.1.173.7.4.3.2.6.1.20INTEGER (1..255)read-writemandatory
ipxInterfaceSerializationEnabled
OBJECT-TYPE
Determines whether NetWare file server serialization security frames will be forwarded on the interface. These broadcasts frames are used by Novell to hold informations regarding the licensing of the file server executables
1.3.6.1.4.1.173.7.4.3.2.6.1.21INTEGER {no(1), yes(2)}read-writemandatory
ipxInterfaceWatchdogSpoofingEnabled
OBJECT-TYPE
Determines whether this interface will be used by the local node to respond to (keep alive) messages on behalf of the client workstations. Novell servers periodically issue these messages to all clients to determine whether each client is still alive
1.3.6.1.4.1.173.7.4.3.2.6.1.22INTEGER {no(1), yes(2)}read-writemandatory
ipxInterfaceLanCardNumber
OBJECT-TYPE
The card number installed in an FRX6000. The first or only LAN card installed is always 0, and the second is card 1
1.3.6.1.4.1.173.7.4.3.2.6.1.23INTEGER (0..1)read-writemandatory
ipxInterfaceWanEnabled
OBJECT-TYPE
Determines whether Novell's IPXWAN protocol will be used on the interface. IPXWAN specifies a method for IPX routers to communicate across WAN links. FRX6000 and FRX4000 implement IPXWAN running over RFC 1490-complaint frame relay and RFC1356-complaint X.25
1.3.6.1.4.1.173.7.4.3.2.6.1.24INTEGER {no(1), yes(2), not-applicable(3)}read-writemandatory
ipxInterfaceSourceSubscriber
OBJECT-TYPE
Subscruber id that defines an IPX interface in the node, by associating itself with port 66 (a number reserved for the IPXinterface) on the RLP that has an IPX installed on it. .. Valid only for type X.25
1.3.6.1.4.1.173.7.4.3.2.6.1.25OCTET STRING (SIZE(0..15))read-writemandatory
ipxInterfaceDestinationSubscriber
OBJECT-TYPE
Subscriber ID associated with the physical X.25 port that will be used for the IPX interface . .. Valid only for type X.25
1.3.6.1.4.1.173.7.4.3.2.6.1.26OCTET STRING (SIZE(0..15))read-writemandatory
ipxInterfaceSVCRetryTimer
OBJECT-TYPE
The frequency with which calls will be placed to try to establish a connection .. Valid only for type X.25
1.3.6.1.4.1.173.7.4.3.2.6.1.27INTEGER (5..60)read-writemandatory
ipxInterfaceSVCIdleTimer
OBJECT-TYPE
is a period that an IPX connection can remain active with no traffic before the connection is cleared. .. Valid only for type X.25
1.3.6.1.4.1.173.7.4.3.2.6.1.28INTEGER (0..5)read-writemandatory
ipxInterfaceMaxVC
OBJECT-TYPE
This specifies a number of virtual circuits over which IPX traffic will be transmitted in parallel. .. Valid only for type X.25
1.3.6.1.4.1.173.7.4.3.2.6.1.29INTEGER (1..8)read-writemandatory
ipxInterfacePVCConnection
OBJECT-TYPE
Identifies this interface as one of a PVC. .. Valid only for type X.25
1.3.6.1.4.1.173.7.4.3.2.6.1.30INTEGER {no(1), yes(2), not-applicable(3)}read-writemandatory
ipxInterfaceSourceCard
OBJECT-TYPE
Identifies the location of this end of the frame relay IPX interface. .. Valid only for frame relay
1.3.6.1.4.1.173.7.4.3.2.6.1.31INTEGER (0..7)read-writemandatory
ipxInterfaceSourcePort
OBJECT-TYPE
Identifies the location of this end of the frame relay IPX interface. .. Valid only for frame relay
1.3.6.1.4.1.173.7.4.3.2.6.1.32INTEGER (0..7)read-writemandatory
ipxInterfaceSourceDLCI
OBJECT-TYPE
Identifies the location of this end of the frame relay IPX interface. .. Valid only for frame relay
1.3.6.1.4.1.173.7.4.3.2.6.1.33INTEGER (16..991)read-writemandatory
ipxInterfaceRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the ipxInterfaceTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.4.3.2.6.1.34RowStatusread-writemandatory
ipxConfigNodeDefault
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.4.3.3
ipxNodeDefaultConfigNetworkAddress
OBJECT-TYPE
Identifies the node to the IPX network
1.3.6.1.4.1.173.7.4.3.3.1INTEGERread-writemandatory
ipxNodeDefaultConfigRIPSAPGap
OBJECT-TYPE
The minimum delay between consecutive RIP and SAP transmissions
1.3.6.1.4.1.173.7.4.3.3.2INTEGER (0..100)read-writemandatory
ipxNodeDefaultConfigRouterName
OBJECT-TYPE
An unique identifier within the IPX network
1.3.6.1.4.1.173.7.4.3.3.3OCTET STRING (SIZE(1..48))read-writemandatory
nlIfIpInterfaces
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.4.4
nlIfIpTable
OBJECT-TYPE
A Table to define IP interfaces over frame relay, X.25, or LAN (ethernet, 802.3, 802.5).
1.3.6.1.4.1.173.7.4.4.1not-accessiblemandatory
nlIfIpEntry
OBJECT-TYPE
An IP Interface entry containing objects relating to IP interfaces.
1.3.6.1.4.1.173.7.4.4.1.1not-accessiblemandatory
nlIfIpInterface
OBJECT-TYPE
The interface number which uniquely identifies the interface to which this entry is applicable. The interface identified by a particular value of this number is NOT the same interface as defined by the same value of ifIndex.
1.3.6.1.4.1.173.7.4.4.1.1.1INTEGER (1..257)read-onlymandatory
nlIfIpMtu
OBJECT-TYPE
The maximum size (in bytes) of the data field that can be used to encapsulate an IP datagram for transmission over the interface. If the interface type is LAN based, then the maximum size value cannot exceed 1500.
1.3.6.1.4.1.173.7.4.4.1.1.2INTEGER (1..4096)read-writemandatory
nlIfIpNetworkMask
OBJECT-TYPE
The mask used during routing to determine the portion of the address associated with the network.
1.3.6.1.4.1.173.7.4.4.1.1.3IpAddressread-writemandatory
nlIfIpRouteMetric
OBJECT-TYPE
The number of network hops (network gateways in the overall path over the internet) associated with this interface.
1.3.6.1.4.1.173.7.4.4.1.1.4INTEGER (0..255)read-writemandatory
nlIfIpICMPAddRoutes
OBJECT-TYPE
The flag which indicates whether IP may add routes obtained by ICMP, whose error and control function is used to send re-direction options back to the source if problems are discovered.
1.3.6.1.4.1.173.7.4.4.1.1.5INTEGER {no(1), yes(2)}read-writemandatory
nlIfIpRIPDeltaUpdates
OBJECT-TYPE
The frequency with which RIP messages will be sent to every neighbor node, containing any changes to the routing table that occurred since the last full update.
1.3.6.1.4.1.173.7.4.4.1.1.6INTEGER (10..300)read-writemandatory
nlIfIpRIPFullUpdates
OBJECT-TYPE
The frequency with which updates of the entire routing table will be sent to every neighbor node, via one or more RIP messages.
1.3.6.1.4.1.173.7.4.4.1.1.7INTEGER (10..300)read-writemandatory
nlIfIpPriority
OBJECT-TYPE
The priority setting for traffic within the node. The higher the number, the higher the priority relative to other intra-nodal traffic.
1.3.6.1.4.1.173.7.4.4.1.1.8INTEGER (0..9)read-writemandatory
nlIfIpBAG
OBJECT-TYPE
The bandwidth allocation group to which this interface is assigned to. This object is only valid when the interface type is frame relay or proprietary virtual.
1.3.6.1.4.1.173.7.4.4.1.1.9INTEGER (1..16)read-writemandatory
nlIfIpType
OBJECT-TYPE
The type of IP interface.
1.3.6.1.4.1.173.7.4.4.1.1.10INTEGER {other(1), rfc877x25(5), ethernetCsmacd(6), iso88023Csmacd(7), iso88025TokenRing(9), frameRelay(32), propVirtual(53)}read-writemandatory
nlIfIpSourceAddress
OBJECT-TYPE
The IP address of the end-to-end sender.
1.3.6.1.4.1.173.7.4.4.1.1.11IpAddressread-writemandatory
nlIfIpDestAddress
OBJECT-TYPE
The IP address of the end-to-end receiver. This object is only valid when the interface type is X.25 or proprietary virtual, or when the interface type is frame relay and the inverse ARP flag indicates disabled.
1.3.6.1.4.1.173.7.4.4.1.1.12IpAddressread-writemandatory
nlIfIpBroadcastAddress
OBJECT-TYPE
The IP address that is used to send to all LAN hosts on the network. This object is only valid when the interface type is LAN based.
1.3.6.1.4.1.173.7.4.4.1.1.13IpAddressread-writemandatory
nlIfIpLANCard
OBJECT-TYPE
The LAN card that contains the interface. This object is only valid when the interface type is LAN based.
1.3.6.1.4.1.173.7.4.4.1.1.14INTEGER (0..1)read-writemandatory
nlIfIpSourceSub
OBJECT-TYPE
The subscriber ID associated with the source IP interface port. This object is only valid when the interface type is X.25.
1.3.6.1.4.1.173.7.4.4.1.1.15NlSubscriberAddressread-writemandatory
nlIfIpDestSub
OBJECT-TYPE
The subscriber ID associated with the destination IP interface port. This object is only valid when the interface type is X.25.
1.3.6.1.4.1.173.7.4.4.1.1.16NlSubscriberAddressread-writemandatory
nlIfIpSVCRetryTimer
OBJECT-TYPE
The frequency with which calls will be placed to try to establish a connection. This object is only valid when the interface type is X.25.
1.3.6.1.4.1.173.7.4.4.1.1.17INTEGER (5..60)read-writemandatory
nlIfIpSVCIdleTimer
OBJECT-TYPE
The period that an IP connection remains active with no traffic before the connection is cleared. This object is only valid when the interface type is X.25.
1.3.6.1.4.1.173.7.4.4.1.1.18INTEGER (0..5)read-writemandatory
nlIfIpMaxSVC
OBJECT-TYPE
The number of virtual circuits over which IP traffic will be transmitted in parallel. This object is only valid when the interface type is X.25.
1.3.6.1.4.1.173.7.4.4.1.1.19INTEGER (1..8)read-writemandatory
nlIfIpPVCConnection
OBJECT-TYPE
The flag which indicates whether this interface is a PVC. This object is only valid when the interface type is X.25.
1.3.6.1.4.1.173.7.4.4.1.1.20INTEGER {no(1), yes(2)}read-writemandatory
nlIfIpSourceRlp
OBJECT-TYPE
The RLP of the logical interface of this end of the frame relay link. This object is only valid when the interface type is frame relay.
1.3.6.1.4.1.173.7.4.4.1.1.21INTEGER (1..8)read-writemandatory
nlIfIpSourcePort
OBJECT-TYPE
The port of the logical interface of this end of the frame relay link. This object is only valid when the interface type is frame relay.
1.3.6.1.4.1.173.7.4.4.1.1.22INTEGER (1..8)read-writemandatory
nlIfIpSourceDLCI
OBJECT-TYPE
The DLCI of the logical interface of this end of the frame relay link. This object is only valid when the interface type is frame relay.
1.3.6.1.4.1.173.7.4.4.1.1.23INTEGER (16..991)read-writemandatory
nlIfIpRIPSupport
OBJECT-TYPE
The RIP support that is being run on the interface.
1.3.6.1.4.1.173.7.4.4.1.1.24INTEGER {disabled(1), enabled(2), receive-only(3)}read-writemandatory
nlIfIpInverseARP
OBJECT-TYPE
The flag which indicates whether inverse ARP is enabled or disabled. This object is only valid when the interface type is frame relay.
1.3.6.1.4.1.173.7.4.4.1.1.25INTEGER {disabled(1), enabled(2)}read-writemandatory
nlIfIpProxyARP
OBJECT-TYPE
The flag which indicates whether proxy ARP is enabled or disabled. This object is only valid when the interface type is LAN based.
1.3.6.1.4.1.173.7.4.4.1.1.26INTEGER {disabled(1), enabled(2)}read-writemandatory
nlIfIpUnnumberedIf
OBJECT-TYPE
The flag which indicates whether this interface is an unnumbered interface (i.e., does not require a specific source IP address). This object is only valid when the interface type is frame relay or X.25.
1.3.6.1.4.1.173.7.4.4.1.1.27INTEGER {no(1), yes(2)}read-writemandatory
nlIfIpRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the nlIfIpTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.4.4.1.1.28RowStatusread-writemandatory
nlIfIpSecondaryAddrTable
OBJECT-TYPE
A Table to define secondary IP interfaces on a LAN (ethernet, 802.3, 802.5) interface.
1.3.6.1.4.1.173.7.4.4.2not-accessiblemandatory
nlIfIpSecondaryAddrEntry
OBJECT-TYPE
An IP Secondary Address entry containing objects relating to IP secondary addresses.
1.3.6.1.4.1.173.7.4.4.2.1not-accessiblemandatory
nlIfIpSecondaryAddrSequence
OBJECT-TYPE
The maximum number of secondary IP addresses that may be configured on an interface.
1.3.6.1.4.1.173.7.4.4.2.1.1INTEGER (1..15)read-writemandatory
nlIfIpSecondaryAddrNetworkMask
OBJECT-TYPE
The mask used during routing to determine the portion of the address associated with the network.
1.3.6.1.4.1.173.7.4.4.2.1.2IpAddressread-writemandatory
nlIfIpSecondaryAddrRouteMetric
OBJECT-TYPE
The number of network hops (network gateways in the overall path over the internet) associated with this interface.
1.3.6.1.4.1.173.7.4.4.2.1.3INTEGER (0..255)read-writemandatory
nlIfIpSecondaryAddrSourceAddress
OBJECT-TYPE
The IP address of the end-to-end sender.
1.3.6.1.4.1.173.7.4.4.2.1.4IpAddressread-writemandatory
nlIfIpSecondaryAddrBroadcastAddress
OBJECT-TYPE
The IP address that is used to send to all LAN hosts on the network.
1.3.6.1.4.1.173.7.4.4.2.1.5IpAddressread-writemandatory
nlIfIpSecondaryAddrRIPSupport
OBJECT-TYPE
The RIP support that is being run on the interface.
1.3.6.1.4.1.173.7.4.4.2.1.6INTEGER {disabled(1), enabled(2), receive-only(3)}read-writemandatory
nlIfIpSecondaryAddrRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the nlIfIpSecondaryAddrTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.4.4.2.1.7RowStatusread-writemandatory
nlIfVoiceInterfaces
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.4.5
nlIfVoiceTable
OBJECT-TYPE
A Table to define Voice interfaces over frame relay.
1.3.6.1.4.1.173.7.4.5.1not-accessiblemandatory
nlIfVoiceEntry
OBJECT-TYPE
A Voice Interface entry containing objects relating to the interface that are configurable by the user.
1.3.6.1.4.1.173.7.4.5.1.1not-accessiblemandatory
nlIfVoiceInterface
OBJECT-TYPE
The interface number which uniquely identifies the interface to which this entry is applicable. The interface identified by a particular value of this number is NOT the same interface as defined by the same value of ifIndex.
1.3.6.1.4.1.173.7.4.5.1.1.1INTEGER (1..129)read-onlymandatory
nlIfVoicePeerNodeType
OBJECT-TYPE
The node type for the node at the remote end of the frame relay connection.
1.3.6.1.4.1.173.7.4.5.1.1.2INTEGER {netlink(1), act(2)}read-writemandatory
nlIfVoicePeerNodeNumber
OBJECT-TYPE
The node number of the remote device.
1.3.6.1.4.1.173.7.4.5.1.1.3INTEGER (1..61)read-writemandatory
nlIfVoicePeerNodePort
OBJECT-TYPE
The voice port on the remote device.
1.3.6.1.4.1.173.7.4.5.1.1.4INTEGER (1..17)read-writemandatory
nlIfVoiceLocalNodeNumber
OBJECT-TYPE
The node number of the local device.
1.3.6.1.4.1.173.7.4.5.1.1.5INTEGER (1..61)read-writemandatory
nlIfVoiceLocalNodePort
OBJECT-TYPE
The voice port on the local device.
1.3.6.1.4.1.173.7.4.5.1.1.6INTEGER (1..17)read-writemandatory
nlIfVoiceFrameRelayRlp
OBJECT-TYPE
The RLP of the logical interface of this end of the frame relay link.
1.3.6.1.4.1.173.7.4.5.1.1.7INTEGER (1..8)read-writemandatory
nlIfVoiceFrameRelayPort
OBJECT-TYPE
The port of the logical interface of this end of the frame relay link.
1.3.6.1.4.1.173.7.4.5.1.1.8INTEGER (1..8)read-writemandatory
nlIfVoiceFrameRelayDLCI
OBJECT-TYPE
The DLCI of the logical interface of this end of the frame relay link.
1.3.6.1.4.1.173.7.4.5.1.1.9INTEGER (16..991)read-writemandatory
nlIfVoiceEnableFragment
OBJECT-TYPE
1.3.6.1.4.1.173.7.4.5.1.1.10INTEGER {no(1), yes(2)}read-writemandatory
nlIfVoiceRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the noIfVoiceTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.4.5.1.1.11RowStatusread-writemandatory
subscriber
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.5
nlLocalSubscriberTable
OBJECT-TYPE
A Table to define each local subscriber.
1.3.6.1.4.1.173.7.5.1not-accessiblemandatory
nlLocalSubscriberEntry
OBJECT-TYPE
A Local Subscriber entry containing objects relating to local subscribers.
1.3.6.1.4.1.173.7.5.1.1not-accessiblemandatory
nlLocalSubscriberId
OBJECT-TYPE
The Subscriber ID. A valid subscriber ID is a string of numeric digits represented by their ASCII equivalents. The ASCII equivalents of the wildcard characters '*' and '?' are also allowed. A '*' is a wildcard that matches any number of digits, including zero. A '?' is a wildcard that matches any single digit.
1.3.6.1.4.1.173.7.5.1.1.1NlSubscriberAddressread-onlymandatory
nlLocalSubscriberName
OBJECT-TYPE
The Subscriber name. The subscriber name is not accessible from SNMP, and a blank string is always returned.
1.3.6.1.4.1.173.7.5.1.1.2DisplayString (SIZE(0..31))read-onlymandatory
nlLocalSubscriberAlgorithm
OBJECT-TYPE
The Subscriber routing algorithm. The following 4 types of routing algorithms are supported. 1 - round robin selects ports specified cyclicly in numerical order according to the list of Redirection addresses. If the port is unreachable or congested, the call request is sent to the next port. 2. Alternate Route on Line Failure - selects the first port not in a failed state. If a connection is not made, the call will be cleared even if other ports are available. 3. Alternate Route on Line Busy - selects the first port that has LCN's available (not busy). If a port has failed, the next available port is selected. 4. Least LCN with throughput selects the line with the minumum loading, calculated by weight and number of LCN's in use. If use of a routing algorithm is not desired, accept the default and specify only one routing path.
1.3.6.1.4.1.173.7.5.1.1.3INTEGER {round-robin(1), line-failed(2), line-busy(3), least-lcn(4)}read-writemandatory
nlLocalSubscriberSystematicRedirect
OBJECT-TYPE
Systematic Redirection.
1.3.6.1.4.1.173.7.5.1.1.4INTEGER {no(1), yes(2)}read-writemandatory
nlLocalSubscriberRedirectBusy
OBJECT-TYPE
Redirect calls according to Redirection Addresses if the primary subscriber device is busy.
1.3.6.1.4.1.173.7.5.1.1.5INTEGER {no(1), yes(2)}read-writemandatory
nlLocalSubscriberRedirectOO
OBJECT-TYPE
Redirect calls according to Redirection Addresses if the primary subscriber device is out of order.
1.3.6.1.4.1.173.7.5.1.1.6INTEGER {no(1), yes(2)}read-writemandatory
nlLocalSubscriberPriority
OBJECT-TYPE
Allows setting a priority for traffic within the node.
1.3.6.1.4.1.173.7.5.1.1.7INTEGER (0..9)read-writemandatory
nlLocalSubscriberRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the nlLocalSubscriberTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.5.1.1.8RowStatusread-writemandatory
nlLocalSubscriberRouteTable
OBJECT-TYPE
A Table to define local subscriber route paths.
1.3.6.1.4.1.173.7.5.2not-accessiblemandatory
nlLocalSubscriberRouteEntry
OBJECT-TYPE
A Local Subscriber Route entry containing objects relating to local subscriber routes.
1.3.6.1.4.1.173.7.5.2.1not-accessiblemandatory
nlLocalSubscriberRouteIndex
OBJECT-TYPE
Route path index for a specific subscriber route path.
1.3.6.1.4.1.173.7.5.2.1.1INTEGER (1..8)read-onlymandatory
nlLocalSubscriberRouteConf
OBJECT-TYPE
Flag to indicate if the LP/port routing path to the subscriber device is configured or not. This object is read- only. The route is always configured for an entry in the table.
1.3.6.1.4.1.173.7.5.2.1.2INTEGER {no(1), yes(2)}read-onlymandatory
nlLocalSubscriberRouteLP
OBJECT-TYPE
Instance of the LP that makes up the routing path
1.3.6.1.4.1.173.7.5.2.1.3INTEGERread-writemandatory
nlLocalSubscriberRoutePort
OBJECT-TYPE
Instance of the port that makes up the routing path
1.3.6.1.4.1.173.7.5.2.1.4INTEGERread-writemandatory
nlLocalSubscriberRouteRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the nlLocalSubscriberRouteTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.5.2.1.5RowStatusread-writemandatory
nlLocalSubscriberRedirTable
OBJECT-TYPE
A Table to list local subscriber redirection addresses.
1.3.6.1.4.1.173.7.5.3not-accessiblemandatory
nlLocalSubscriberRedirEntry
OBJECT-TYPE
A Local Subscriber Redirection Address entry containing objects relating to local subscriber redirection addresses.
1.3.6.1.4.1.173.7.5.3.1not-accessiblemandatory
nlLocalSubscriberRedirIndex
OBJECT-TYPE
Redirection entry index for a local subscriber.
1.3.6.1.4.1.173.7.5.3.1.1INTEGER (1..5)read-onlymandatory
nlLocalSubscriberRedirAddr
OBJECT-TYPE
Subscriber redirection address.
1.3.6.1.4.1.173.7.5.3.1.2NlSubscriberAddressread-writemandatory
nlLocalSubscriberRedirRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the nlLocalSubscriberRedirTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.5.3.1.3RowStatusread-writemandatory
llc2
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.6
nlLlc2HostTable
OBJECT-TYPE
A Table to define LLC2 host entries.
1.3.6.1.4.1.173.7.6.1not-accessiblemandatory
nlLlc2HostEntry
OBJECT-TYPE
An LLC2 Host entry containing objects relating to LLC2 hosts.
1.3.6.1.4.1.173.7.6.1.1not-accessiblemandatory
nlLlc2HostIndex
OBJECT-TYPE
LLC2 Host Index
1.3.6.1.4.1.173.7.6.1.1.1INTEGER (1..251)read-onlymandatory
nlLlc2HostMACAddress
OBJECT-TYPE
The LLC2 Host MAC Address.
1.3.6.1.4.1.173.7.6.1.1.2MacAddressread-writemandatory
nlLlc2HostSessionType
OBJECT-TYPE
The mode in which the Host is operating
1.3.6.1.4.1.173.7.6.1.1.3INTEGER {originated(1), terminated(2)}read-writemandatory
nlLlc2HostT1ReplyTimer
OBJECT-TYPE
Reply Timer used to detect a failure of the Remote node.
1.3.6.1.4.1.173.7.6.1.1.4TimeInterval (1..250)read-writemandatory
nlLlc2HostT2RecvAckTimer
OBJECT-TYPE
Receive Ack Timer used to delay sending an acknowledgement of a received information LPDU.
1.3.6.1.4.1.173.7.6.1.1.5TimeInterval (100..5000)read-writemandatory
nlLlc2HostTiInactivityTimer
OBJECT-TYPE
Timer used to detect inoperative condition of the remote link station or transmission medium.
1.3.6.1.4.1.173.7.6.1.1.6TimeInterval (1..50)read-writemandatory
nlLlc2HostN3NumberLPDUs
OBJECT-TYPE
The number of Information LPDUs that need to be received before an acknowledgement is sent.
1.3.6.1.4.1.173.7.6.1.1.7INTEGER (1..127)read-writemandatory
nlLlc2HostTwNumberOutstanding
OBJECT-TYPE
Maximum number of sequentially numbered information LPDUs that can be outstanding at any time.
1.3.6.1.4.1.173.7.6.1.1.8INTEGER (1..127)read-writemandatory
nlLlc2HostN2ExpiredT1LPDUCount
OBJECT-TYPE
Maximum number of LPDU retransmissions occur following the expiration of Timer T1.
1.3.6.1.4.1.173.7.6.1.1.9INTEGER (0..255)read-writemandatory
nlLlc2HostPriority
OBJECT-TYPE
Traffic priorities within the node.
1.3.6.1.4.1.173.7.6.1.1.10INTEGER (0..9)read-writemandatory
nlLlc2HostBAG
OBJECT-TYPE
Bandwidth Allocation group to which the LLC2 Host belongs. This object is read-only. Bandwidth allocation groups do not apply to LLC2 hosts.
1.3.6.1.4.1.173.7.6.1.1.11INTEGER (1..16)read-onlymandatory
nlLlc2HostRoutingSubscriberId
OBJECT-TYPE
LLC2 hosts Routing Subscriber Id
1.3.6.1.4.1.173.7.6.1.1.12NlSubscriberAddressread-writemandatory
nlLlc2HostSrcMACAddressMask
OBJECT-TYPE
LLC2 Host's Source MAC Address Mask
1.3.6.1.4.1.173.7.6.1.1.13MacAddressread-writemandatory
nlLlc2HostAccess
OBJECT-TYPE
Specifies different type(s) of interface(s) that can be used for connections to a terminated host session.
1.3.6.1.4.1.173.7.6.1.1.14INTEGER {lan(1), frameRelay(2), tokenRing(3), ethernet(4), all(5), not-applicable(6)}read-onlymandatory
nlLlc2HostRowStatus
OBJECT-TYPE
Row status convention for LLC2 Host entry.
1.3.6.1.4.1.173.7.6.1.1.15RowStatusread-writemandatory
nlLlc2HostInterface
OBJECT-TYPE
LLC2 interface number associated with this host entry, always 300 for non-FRX7000.
1.3.6.1.4.1.173.7.6.1.1.16INTEGERread-onlymandatory
nlLlc2HostGroup
OBJECT-TYPE
Traffic group associated with LLC2 interface, always 1 for non-FRX7000.
1.3.6.1.4.1.173.7.6.1.1.17INTEGER (1..4)read-onlymandatory
nlLlc2TermConnectionTable
OBJECT-TYPE
A Table to describe LLC2 Terminated Host Connections.
1.3.6.1.4.1.173.7.6.2not-accessiblemandatory
nlLlc2TermConnectionEntry
OBJECT-TYPE
An LLC2 Terminated Host Connection entry containing objects relating to LLC2 terminated host connections.
1.3.6.1.4.1.173.7.6.2.1not-accessiblemandatory
nlLlc2TermConnectionSequence
OBJECT-TYPE
LLC2 Host connection Sequence number
1.3.6.1.4.1.173.7.6.2.1.1INTEGER (1..16)read-onlymandatory
nlLlc2TermConnectionHSAP
OBJECT-TYPE
Service Access point used to connect to the Host
1.3.6.1.4.1.173.7.6.2.1.2INTEGER (4..254)read-writemandatory
nlLlc2TermConnectionLocalSubscriberId
OBJECT-TYPE
LLC2 Host Connection's Local Subscriber Id
1.3.6.1.4.1.173.7.6.2.1.3NlSubscriberAddressread-writemandatory
nlLlc2TermConnectionRemoteSubscriberId
OBJECT-TYPE
LLC2 Host Connection's Remote Subscriber Id
1.3.6.1.4.1.173.7.6.2.1.4NlSubscriberAddressread-writemandatory
nlLlc2TermConnectionRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the nlLlc2TermConnectionTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.6.2.1.5RowStatusread-writemandatory
nlLlc2OrigConnectionTable
OBJECT-TYPE
A Table to describe LLC2 Originated Host Connections.
1.3.6.1.4.1.173.7.6.3not-accessiblemandatory
nlLlc2OrigConnectionEntry
OBJECT-TYPE
An LLC2 Originated Host Connection entry containing objects relating to LLC2 originated host connections.
1.3.6.1.4.1.173.7.6.3.1not-accessiblemandatory
nlLlc2OrigConnectionSequence
OBJECT-TYPE
LLC2 Host connection Sequence number
1.3.6.1.4.1.173.7.6.3.1.1INTEGER (1..16)read-onlymandatory
nlLlc2OrigConnectionHSAP
OBJECT-TYPE
Service Access point used to connect to the Host
1.3.6.1.4.1.173.7.6.3.1.2INTEGER (4..254)read-writemandatory
nlLlc2OrigConnectionType
OBJECT-TYPE
Specifies Remote subscriber device type
1.3.6.1.4.1.173.7.6.3.1.3INTEGER {sdlc(1), llc2(2)}read-writemandatory
nlLlc2OrigConnectionLocalSubscriberId
OBJECT-TYPE
LLC2 Host Connection's Local Subscriber Id
1.3.6.1.4.1.173.7.6.3.1.4NlSubscriberAddressread-writemandatory
nlLlc2OrigConnectionRemoteSubscriberId
OBJECT-TYPE
LLC2 Host Connection's Remote Subscriber Id
1.3.6.1.4.1.173.7.6.3.1.5NlSubscriberAddressread-writemandatory
nlLlc2OrigConnectionIDBLK
OBJECT-TYPE
This field is obsolete
1.3.6.1.4.1.173.7.6.3.1.6INTEGERread-onlymandatory
nlLlc2OrigConnectionIDNUM
OBJECT-TYPE
This field is obsolete
1.3.6.1.4.1.173.7.6.3.1.7INTEGERread-onlymandatory
nlLlc2OrigConnectionMAXDATA
OBJECT-TYPE
This field is obsolete
1.3.6.1.4.1.173.7.6.3.1.8INTEGERread-onlymandatory
nlLlc2OrigConnectionMAXIN
OBJECT-TYPE
This field is obsolete
1.3.6.1.4.1.173.7.6.3.1.9INTEGERread-onlymandatory
nlLlc2OrigConnectionRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the nlLlc2OrigConnectionTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.6.3.1.10RowStatusread-writemandatory
nlLlc2NextHostNumber
OBJECT-TYPE
The host number to be used for the next created host record, always 1 on non-FRX7000.
1.3.6.1.4.1.173.7.6.4INTEGERread-onlymandatory
status
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.7
pinStatusTable
OBJECT-TYPE
A Table to describe the status of each pin on a physical port. This table is indexed by RLP and Port
1.3.6.1.4.1.173.7.7.4not-accessiblemandatory
portPinEntry
OBJECT-TYPE
A port pin entry containing objects relating to ports.
1.3.6.1.4.1.173.7.7.4.1not-accessiblemandatory
portPinRlp
OBJECT-TYPE
The RLP number on the node
1.3.6.1.4.1.173.7.7.4.1.1INTEGERread-onlymandatory
portPinPort
OBJECT-TYPE
The Port number on the RLP. Port numbers 0-7 are known to be physical ports.
1.3.6.1.4.1.173.7.7.4.1.2INTEGERread-onlymandatory
portPinStatus
OBJECT-TYPE
The status of all pins for this physical port. There is one octet value for each of the pins. Each octet value is defined as follows: 00 = unknown 01 = active 02 = inactive 03 = unused
1.3.6.1.4.1.173.7.7.4.1.3OCTET STRINGread-onlymandatory
statistics
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.8
statGroup
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.8.1
rlpStatsTable
OBJECT-TYPE
A Table to describe Statistics on each RLP
1.3.6.1.4.1.173.7.8.1.2not-accessiblemandatory
rlpStatsEntry
OBJECT-TYPE
An RLP statistics entry containing objects relating to RLP statistics.
1.3.6.1.4.1.173.7.8.1.2.1not-accessiblemandatory
rlpStatsIndex
OBJECT-TYPE
The RLP number
1.3.6.1.4.1.173.7.8.1.2.1.1INTEGERread-onlymandatory
rlpStatsQMessages
OBJECT-TYPE
The number of frames queued on the RLP
1.3.6.1.4.1.173.7.8.1.2.1.2Counterread-onlymandatory
rlpStatsUsedBuffers
OBJECT-TYPE
The percentage of total buffers available being used at the moment of inquiry
1.3.6.1.4.1.173.7.8.1.2.1.3Counterread-onlymandatory
rlpStatsInFrames
OBJECT-TYPE
The number of frames received.
1.3.6.1.4.1.173.7.8.1.2.1.4Counterread-onlymandatory
rlpStatsOutFrames
OBJECT-TYPE
The number of frames transmitted.
1.3.6.1.4.1.173.7.8.1.2.1.5Counterread-onlymandatory
rlpStatsFrameRejects
OBJECT-TYPE
The number of frames rejected.
1.3.6.1.4.1.173.7.8.1.2.1.6Counterread-onlymandatory
rlpStatsFrameRetransmits
OBJECT-TYPE
The number of frames retransmitted . If this value is consistently greater than zero and there are no other problems, then increase the retransmission parameter.
1.3.6.1.4.1.173.7.8.1.2.1.7Counterread-onlymandatory
portStatsTable
OBJECT-TYPE
A Table to describe Statistics on each RLP
1.3.6.1.4.1.173.7.8.1.3not-accessiblemandatory
portStatsEntry
OBJECT-TYPE
A port statistics entry containing objects relating to port statistics.
1.3.6.1.4.1.173.7.8.1.3.1not-accessiblemandatory
portStatsRlpIndex
OBJECT-TYPE
The RLP number
1.3.6.1.4.1.173.7.8.1.3.1.1INTEGERread-onlymandatory
portStatsIndex
OBJECT-TYPE
The Port number
1.3.6.1.4.1.173.7.8.1.3.1.2INTEGERread-onlymandatory
portStatsInFrames
OBJECT-TYPE
The number of frames received.
1.3.6.1.4.1.173.7.8.1.3.1.3Counterread-onlymandatory
portStatsOutFrames
OBJECT-TYPE
The number of frames transmitted.
1.3.6.1.4.1.173.7.8.1.3.1.4Counterread-onlymandatory
portStatsFrameRetrans
OBJECT-TYPE
The number of frames retransmitted.
1.3.6.1.4.1.173.7.8.1.3.1.5Counterread-onlymandatory
portStatsFCSErrors
OBJECT-TYPE
The number of Frame Check Sequence (FCS) errors. A value consistently greater than zero indicates line probelms.
1.3.6.1.4.1.173.7.8.1.3.1.6Counterread-onlymandatory
portStatsLogicalRejects
OBJECT-TYPE
The sum of Rejects and Frame Rejects. A value consistently greater than zero indicates line probelms.
1.3.6.1.4.1.173.7.8.1.3.1.7Counterread-onlymandatory
portStatsInPercentUtils
OBJECT-TYPE
The ratio of non-flag characters to total characters being received by the port.
1.3.6.1.4.1.173.7.8.1.3.1.8Counterread-onlymandatory
portStatsOutPercentUtils
OBJECT-TYPE
The ration of non-flag characters to total characters being transmitted by the port.
1.3.6.1.4.1.173.7.8.1.3.1.9Counterread-onlymandatory
statFrame
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.8.1.4
frStatsTable
OBJECT-TYPE
A Table to describe Frame Relay Frame Level Statistics on each Port
1.3.6.1.4.1.173.7.8.1.4.1not-accessiblemandatory
frStatsEntry
OBJECT-TYPE
A frame relay port statistics entry containing objects relating to frame relay port statistics.
1.3.6.1.4.1.173.7.8.1.4.1.1not-accessiblemandatory
frStatsRlpIndex
OBJECT-TYPE
The RLP Number.
1.3.6.1.4.1.173.7.8.1.4.1.1.1INTEGERread-onlymandatory
frStatsPortIndex
OBJECT-TYPE
The Port number.
1.3.6.1.4.1.173.7.8.1.4.1.1.2INTEGERread-onlymandatory
frStatsTxDEFrames
OBJECT-TYPE
The number of frames transmitted on the port with the Discard Eligibility bit set.
1.3.6.1.4.1.173.7.8.1.4.1.1.3Counterread-onlymandatory
frStatsRxDEFrames
OBJECT-TYPE
The number of frames received on the port with the discard eligibility bit set.
1.3.6.1.4.1.173.7.8.1.4.1.1.4Counterread-onlymandatory
frStatsTxFECNFrames
OBJECT-TYPE
The of number of frames transmitted on the port with FECN.
1.3.6.1.4.1.173.7.8.1.4.1.1.5Counterread-onlymandatory
frStatsRxFECNFrames
OBJECT-TYPE
The number of frames received on the port with FECN.
1.3.6.1.4.1.173.7.8.1.4.1.1.6Counterread-onlymandatory
frStatsTxBECNFrames
OBJECT-TYPE
The number of frames transmitted on the port with BECN.
1.3.6.1.4.1.173.7.8.1.4.1.1.7Counterread-onlymandatory
frStatsRxBECNFrames
OBJECT-TYPE
The number of frames received on the port with BECN.
1.3.6.1.4.1.173.7.8.1.4.1.1.8Counterread-onlymandatory
frStatsTxLMIFrames
OBJECT-TYPE
The number of LMI frames transmitted on the port.
1.3.6.1.4.1.173.7.8.1.4.1.1.9Counterread-onlymandatory
frStatsRxLMIFrames
OBJECT-TYPE
The number of LMI frames received on the port.
1.3.6.1.4.1.173.7.8.1.4.1.1.10Counterread-onlymandatory
frStatsTxANXDFrames
OBJECT-TYPE
The number of AnnexD frames transmitted on the port
1.3.6.1.4.1.173.7.8.1.4.1.1.11Counterread-onlymandatory
frStatsRxANXDFrames
OBJECT-TYPE
The number of AnnexD frames received on the port
1.3.6.1.4.1.173.7.8.1.4.1.1.12Counterread-onlymandatory
frStatsTotDiscFrames
OBJECT-TYPE
The total number of discarded frames on the port.
1.3.6.1.4.1.173.7.8.1.4.1.1.13Counterread-onlymandatory
x25TxStatsTable
OBJECT-TYPE
A Table to describe X25 Frame Level Txmit Statistics on each Port
1.3.6.1.4.1.173.7.8.1.4.2not-accessiblemandatory
x25TxStatsEntry
OBJECT-TYPE
An X25 frame level transmit statistics entry containing objects relating to x25 frame level transmit statistics.
1.3.6.1.4.1.173.7.8.1.4.2.1not-accessiblemandatory
x25TxRlpIndex
OBJECT-TYPE
The RLP Number.
1.3.6.1.4.1.173.7.8.1.4.2.1.1INTEGERread-onlymandatory
x25TxPortIndex
OBJECT-TYPE
The Port number.
1.3.6.1.4.1.173.7.8.1.4.2.1.2INTEGERread-onlymandatory
x25TxSABMFrames
OBJECT-TYPE
The number of SABM's transmitted on the port.
1.3.6.1.4.1.173.7.8.1.4.2.1.3Counterread-onlymandatory
x25TxUAFrames
OBJECT-TYPE
The number of UA Frames transmitted on the port.
1.3.6.1.4.1.173.7.8.1.4.2.1.4Counterread-onlymandatory
x25TxDISCFrames
OBJECT-TYPE
The number of DISC Frames transmitted on the port.
1.3.6.1.4.1.173.7.8.1.4.2.1.5Counterread-onlymandatory
x25TxDMFrames
OBJECT-TYPE
The number of DM frames transmitted on the port.
1.3.6.1.4.1.173.7.8.1.4.2.1.6Counterread-onlymandatory
x25TxFRMRFrames
OBJECT-TYPE
The of Number of FRMR frames transmitted on the port.
1.3.6.1.4.1.173.7.8.1.4.2.1.7Counterread-onlymandatory
x25TxREJFrames
OBJECT-TYPE
The number of Reject Frames transmitted on the port.
1.3.6.1.4.1.173.7.8.1.4.2.1.8Counterread-onlymandatory
x25TxRRFrames
OBJECT-TYPE
The number of RR frames transmitted on the port.
1.3.6.1.4.1.173.7.8.1.4.2.1.9Counterread-onlymandatory
x25TxRNRFrames
OBJECT-TYPE
The number of RNR Frames transmitted on the port.
1.3.6.1.4.1.173.7.8.1.4.2.1.10Counterread-onlymandatory
x25TxINFOFrames
OBJECT-TYPE
The number of INFO Frames transmitted on the port
1.3.6.1.4.1.173.7.8.1.4.2.1.11Counterread-onlymandatory
x25RxStatsTable
OBJECT-TYPE
A Table to describe X25 Frame Level Rxmit Statistics on each Port
1.3.6.1.4.1.173.7.8.1.4.3not-accessiblemandatory
x25RxStatsEntry
OBJECT-TYPE
An X25 frame level receive statistics entry containing objects relating to x25 frame level receive statistics.
1.3.6.1.4.1.173.7.8.1.4.3.1not-accessiblemandatory
x25RxRlpIndex
OBJECT-TYPE
The RLP Number.
1.3.6.1.4.1.173.7.8.1.4.3.1.1INTEGERread-onlymandatory
x25RxPortIndex
OBJECT-TYPE
The Port number.
1.3.6.1.4.1.173.7.8.1.4.3.1.2INTEGERread-onlymandatory
x25RxSABMFrames
OBJECT-TYPE
The number of SABM's received on the port.
1.3.6.1.4.1.173.7.8.1.4.3.1.3Counterread-onlymandatory
x25RxUAFrames
OBJECT-TYPE
The number of UA Frames received on the port.
1.3.6.1.4.1.173.7.8.1.4.3.1.4Counterread-onlymandatory
x25RxDISCFrames
OBJECT-TYPE
The number of DISC Frames received on the port.
1.3.6.1.4.1.173.7.8.1.4.3.1.5Counterread-onlymandatory
x25RxDMFrames
OBJECT-TYPE
The number of DM frames received on the port.
1.3.6.1.4.1.173.7.8.1.4.3.1.6Counterread-onlymandatory
x25RxFRMRFrames
OBJECT-TYPE
The of Number of FRMR frames received on the port.
1.3.6.1.4.1.173.7.8.1.4.3.1.7Counterread-onlymandatory
x25RxREJFrames
OBJECT-TYPE
The number of Reject Frames received on the port.
1.3.6.1.4.1.173.7.8.1.4.3.1.8Counterread-onlymandatory
x25RxRRFrames
OBJECT-TYPE
The number of RR frames received on the port.
1.3.6.1.4.1.173.7.8.1.4.3.1.9Counterread-onlymandatory
x25RxRNRFrames
OBJECT-TYPE
The number of RNR Frames received on the port.
1.3.6.1.4.1.173.7.8.1.4.3.1.10Counterread-onlymandatory
x25RxINFOFrames
OBJECT-TYPE
The number of INFO Frames received on the port
1.3.6.1.4.1.173.7.8.1.4.3.1.11Counterread-onlymandatory
statBag
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.8.1.5
statIp
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.8.1.6
statT1
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.8.1.7
t1StatsTable
OBJECT-TYPE
A Table to describe T1 Statistics.
1.3.6.1.4.1.173.7.8.1.7.1not-accessiblemandatory
t1StatsEntry
OBJECT-TYPE
A T1 port statistics entry containing objects relating to T1 port statistics.
1.3.6.1.4.1.173.7.8.1.7.1.1not-accessiblemandatory
t1StatsRlpIndex
OBJECT-TYPE
The RLP Number.
1.3.6.1.4.1.173.7.8.1.7.1.1.1INTEGERread-onlymandatory
t1StatsPortIndex
OBJECT-TYPE
The Port Number.
1.3.6.1.4.1.173.7.8.1.7.1.1.2INTEGERread-onlymandatory
t1StatsRcvFrames
OBJECT-TYPE
Total received frames.
1.3.6.1.4.1.173.7.8.1.7.1.1.3Counterread-onlymandatory
t1StatsXmitFrames
OBJECT-TYPE
Total transmitted frames.
1.3.6.1.4.1.173.7.8.1.7.1.1.4Counterread-onlymandatory
t1StatsLCVCnt
OBJECT-TYPE
Line code violation count.
1.3.6.1.4.1.173.7.8.1.7.1.1.5Counterread-onlymandatory
t1StatsPCVRErrs
OBJECT-TYPE
PCVR Bit error count.
1.3.6.1.4.1.173.7.8.1.7.1.1.6Counterread-onlymandatory
t1StatsOOSCnt
OBJECT-TYPE
Multiframe out of sync count.
1.3.6.1.4.1.173.7.8.1.7.1.1.7Counterread-onlymandatory
t1StatsBlueAlarms
OBJECT-TYPE
Blue alarm count.
1.3.6.1.4.1.173.7.8.1.7.1.1.8Counterread-onlymandatory
t1StatsYellowAlarms
OBJECT-TYPE
Yellow alarm count.
1.3.6.1.4.1.173.7.8.1.7.1.1.9Counterread-onlymandatory
t1StatsRedAlarms
OBJECT-TYPE
Red alarm count.
1.3.6.1.4.1.173.7.8.1.7.1.1.10Counterread-onlymandatory
t1StatsRcvUsage
OBJECT-TYPE
Receive port utilization.
1.3.6.1.4.1.173.7.8.1.7.1.1.11Counterread-onlymandatory
t1StatsXmitUsage
OBJECT-TYPE
Transmit port utilization.
1.3.6.1.4.1.173.7.8.1.7.1.1.12Counterread-onlymandatory
t1StatsXmitAbortFrames
OBJECT-TYPE
Total aborted transmit frames.
1.3.6.1.4.1.173.7.8.1.7.1.1.13Counterread-onlymandatory
t1StatsRcvAbortFrames
OBJECT-TYPE
Total aborted receive frames.
1.3.6.1.4.1.173.7.8.1.7.1.1.14Counterread-onlymandatory
t1StatsRcvOverruns
OBJECT-TYPE
Total receive overruns.
1.3.6.1.4.1.173.7.8.1.7.1.1.15Counterread-onlymandatory
t1StatsRcvErrors
OBJECT-TYPE
Total bad receives.
1.3.6.1.4.1.173.7.8.1.7.1.1.16Counterread-onlymandatory
t1StatsRcvChannelErrors
OBJECT-TYPE
Total bad receives.
1.3.6.1.4.1.173.7.8.1.7.1.1.17Counterread-onlymandatory
statDS0A
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.8.1.8
ds0aStatsTable
OBJECT-TYPE
A Table to describe DS0A Statistics.
1.3.6.1.4.1.173.7.8.1.8.1not-accessiblemandatory
ds0aStatsEntry
OBJECT-TYPE
A DS0A port statistics entry containing objects relating to DS0A port statistics.
1.3.6.1.4.1.173.7.8.1.8.1.1not-accessiblemandatory
ds0aStatsRlpIndex
OBJECT-TYPE
The RLP Number.
1.3.6.1.4.1.173.7.8.1.8.1.1.1INTEGERread-onlymandatory
ds0aStatsPortIndex
OBJECT-TYPE
The Port Number.
1.3.6.1.4.1.173.7.8.1.8.1.1.2INTEGERread-onlymandatory
ds0aStatsChannelIndex
OBJECT-TYPE
The Channel Number.
1.3.6.1.4.1.173.7.8.1.8.1.1.3INTEGERread-onlymandatory
ds0aStatsXmitFrames
OBJECT-TYPE
Total transmitted frames.
1.3.6.1.4.1.173.7.8.1.8.1.1.4Counterread-onlymandatory
ds0aStatsRcvFrames
OBJECT-TYPE
Total received frames.
1.3.6.1.4.1.173.7.8.1.8.1.1.5Counterread-onlymandatory
ds0aStatsRcvAbortFrames
OBJECT-TYPE
Total receive aborted frames.
1.3.6.1.4.1.173.7.8.1.8.1.1.6Counterread-onlymandatory
ds0aStatsRcvOverruns
OBJECT-TYPE
Total receive overruns.
1.3.6.1.4.1.173.7.8.1.8.1.1.7Counterread-onlymandatory
ds0aStatsRcvErrors
OBJECT-TYPE
Total receive errors.
1.3.6.1.4.1.173.7.8.1.8.1.1.8Counterread-onlymandatory
statVoice
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.8.1.9
voiceStatsTable
OBJECT-TYPE
A Table to describe Voice over Frame Relay Statistics.
1.3.6.1.4.1.173.7.8.1.9.1not-accessiblemandatory
voiceStatsEntry
OBJECT-TYPE
A voice port statistics entry containing objects relating to voice port statistics.
1.3.6.1.4.1.173.7.8.1.9.1.1not-accessiblemandatory
voiceStatsRlpIndex
OBJECT-TYPE
The RLP Number.
1.3.6.1.4.1.173.7.8.1.9.1.1.1INTEGERread-onlymandatory
voiceStatsPortIndex
OBJECT-TYPE
The Port Number.
1.3.6.1.4.1.173.7.8.1.9.1.1.2INTEGERread-onlymandatory
voiceStatsRxCalls
OBJECT-TYPE
The Number of Calls Received from the Network.
1.3.6.1.4.1.173.7.8.1.9.1.1.3Counterread-onlymandatory
voiceStatsTxCalls
OBJECT-TYPE
The Number of Calls Transmitted to the Network.
1.3.6.1.4.1.173.7.8.1.9.1.1.4Counterread-onlymandatory
voiceStatsRxCallsAccepts
OBJECT-TYPE
The Number of Call Accepts Received from the Network.
1.3.6.1.4.1.173.7.8.1.9.1.1.5Counterread-onlymandatory
voiceStatsTxCallsAccepts
OBJECT-TYPE
The Number of Call Accepts Transmitted to the Network.
1.3.6.1.4.1.173.7.8.1.9.1.1.6Counterread-onlymandatory
voiceStatsRxClears
OBJECT-TYPE
The Number of Call Receives cleared.
1.3.6.1.4.1.173.7.8.1.9.1.1.7Counterread-onlymandatory
voiceStatsTxClears
OBJECT-TYPE
The Number of Call Transmitts cleared.
1.3.6.1.4.1.173.7.8.1.9.1.1.8Counterread-onlymandatory
voiceStatsBusyCalls
OBJECT-TYPE
The Number of calls which received Busy indication.
1.3.6.1.4.1.173.7.8.1.9.1.1.9Counterread-onlymandatory
voiceStatsCallTimeouts
OBJECT-TYPE
The Number of calls which transmitted time-out to the network.
1.3.6.1.4.1.173.7.8.1.9.1.1.10Counterread-onlymandatory
voiceStatsRxCongestions
OBJECT-TYPE
The number of congestion management frames Received.
1.3.6.1.4.1.173.7.8.1.9.1.1.11Counterread-onlymandatory
voiceStatsTxCongestions
OBJECT-TYPE
The number of congestion management frames Transmitted.
1.3.6.1.4.1.173.7.8.1.9.1.1.12Counterread-onlymandatory
statThresh
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.8.2
rlpThreshTable
OBJECT-TYPE
A Table to describe Statistic thresholds on each RLP
1.3.6.1.4.1.173.7.8.2.1not-accessiblemandatory
rlpThreshEntry
OBJECT-TYPE
An RLP statistics threshold entry containing objects relating to RLP statistics thresholds.
1.3.6.1.4.1.173.7.8.2.1.1not-accessiblemandatory
rlpThreshRlpIndex
OBJECT-TYPE
The RLP Number.
1.3.6.1.4.1.173.7.8.2.1.1.1INTEGERread-onlymandatory
rlpThreshPercntBufInUse
OBJECT-TYPE
The threshold for Percent of Buffers in use on the RLP
1.3.6.1.4.1.173.7.8.2.1.1.2INTEGERread-onlymandatory
rlpThreshMsgQueueLen
OBJECT-TYPE
The threshold for Percent of Buffers in use on the RLP
1.3.6.1.4.1.173.7.8.2.1.1.3INTEGERread-onlymandatory
rlpThreshRxFramesPerSec
OBJECT-TYPE
The threshold for Rcvd frames per second on the RLP
1.3.6.1.4.1.173.7.8.2.1.1.4INTEGERread-onlymandatory
rlpThreshTxFramesPerSec
OBJECT-TYPE
The threshold for Txmitted frames per second on the RLP
1.3.6.1.4.1.173.7.8.2.1.1.5INTEGERread-onlymandatory
rlpThreshRejFramesPerSec
OBJECT-TYPE
The threshold for Rejected Frames per second on the RLP
1.3.6.1.4.1.173.7.8.2.1.1.6INTEGERread-onlymandatory
rlpThreshRtxFramesPerSec
OBJECT-TYPE
The threshold for Retransmitted frames per second on the RLP
1.3.6.1.4.1.173.7.8.2.1.1.7INTEGERread-onlymandatory
portThreshTable
OBJECT-TYPE
A Table to describe Statistic thresholds on each port
1.3.6.1.4.1.173.7.8.2.2not-accessiblemandatory
portThreshEntry
OBJECT-TYPE
A port statistics threshold entry containing objects relating to port statistics thresholds.
1.3.6.1.4.1.173.7.8.2.2.1not-accessiblemandatory
portThreshRlpIndex
OBJECT-TYPE
The RLP Number.
1.3.6.1.4.1.173.7.8.2.2.1.1INTEGERread-onlymandatory
portThreshIndex
OBJECT-TYPE
The Port Number.
1.3.6.1.4.1.173.7.8.2.2.1.2INTEGERread-onlymandatory
portThreshRxFramesPerSec
OBJECT-TYPE
The threshold for Rcvd frames per second on the port.
1.3.6.1.4.1.173.7.8.2.2.1.3INTEGERread-onlymandatory
portThreshTxFramesPerSec
OBJECT-TYPE
The threshold for Txmitted frames per second on the port.
1.3.6.1.4.1.173.7.8.2.2.1.4INTEGERread-onlymandatory
portThreshRtxFramesPerSec
OBJECT-TYPE
The threshold for Retransmitted frames per second on the port.
1.3.6.1.4.1.173.7.8.2.2.1.5INTEGERread-onlymandatory
portThreshFCSErrPerSec
OBJECT-TYPE
The threshold for FCS errors per second on the port.
1.3.6.1.4.1.173.7.8.2.2.1.6INTEGERread-onlymandatory
portThreshLogRejPerSec
OBJECT-TYPE
The threshold for Logical Rejects per second on the port.
1.3.6.1.4.1.173.7.8.2.2.1.7INTEGERread-onlymandatory
portThreshTxErrorRatio
OBJECT-TYPE
The threshold for Txmit error ratio on the port.
1.3.6.1.4.1.173.7.8.2.2.1.8INTEGERread-onlymandatory
portThreshRxErrorRatio
OBJECT-TYPE
The threshold for Rcv error ratio on the port.
1.3.6.1.4.1.173.7.8.2.2.1.9INTEGERread-onlymandatory
portThreshTxPercentUtl
OBJECT-TYPE
The threshold for Txmit percent utilization on the port.
1.3.6.1.4.1.173.7.8.2.2.1.10INTEGERread-onlymandatory
portThreshRxPercentUtl
OBJECT-TYPE
The threshold for Rcv percent utilization on the port.
1.3.6.1.4.1.173.7.8.2.2.1.11INTEGERread-onlymandatory
bridge
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.9
bridgeAdminVirtualLANID
OBJECT-TYPE
LAN id inserted into token ring RIF field representing internal virtual ring, for LLC2 or bridged traffic
1.3.6.1.4.1.173.7.9.1INTEGER (0..4095)read-writemandatory
bridgeOperVirtualLANID
OBJECT-TYPE
LAN id inserted into token ring RIF field representing internal virtual ring, for LLC2 or bridged traffic
1.3.6.1.4.1.173.7.9.2INTEGER (0..4095)read-onlymandatory
bridgeEnabled
OBJECT-TYPE
When yes the spanning tree algorithm is in effect and all traffic types may be bridged. When no only llc/2 terminated traffic is allowed on bridge interfaces.
1.3.6.1.4.1.173.7.9.3INTEGER {no(1), yes(2)}read-writemandatory
bridgeMaxSizeForwardingTable
OBJECT-TYPE
Number of entries allowed in the bridge forwarding table
1.3.6.1.4.1.173.7.9.4INTEGER (128..65535)read-writemandatory
bridgeIPEnabled
OBJECT-TYPE
When yes, and BRIDGING ENABLED, IP traffic will be bridged, otherwise IP traffic will be routed.
1.3.6.1.4.1.173.7.9.5INTEGER {no(1), yes(2)}read-writemandatory
bridgeIPXEnabled
OBJECT-TYPE
When yes, and BRIDGING ENABLED, IPX traffic will be bridged, otherwise IPX traffic will be routed.
1.3.6.1.4.1.173.7.9.6INTEGER {no(1), yes(2)}read-writemandatory
bridgeAdminSRBID
OBJECT-TYPE
bridge ID to be inserted into token ring RIF field, this bridge
1.3.6.1.4.1.173.7.9.7INTEGER (0..15)read-writemandatory
bridgeOperSRBID
OBJECT-TYPE
bridge ID to be inserted into token ring RIF field, this bridge
1.3.6.1.4.1.173.7.9.8INTEGER (0..15)read-onlymandatory
bridgeDefaultEthernetFrameType
OBJECT-TYPE
default frame type to be used when forwarding traffic on ethernet interfaces.
1.3.6.1.4.1.173.7.9.9INTEGER {type-II(1), ieee8023(2)}read-writemandatory
ipNl
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.11
nlIpDefaultRIPVersion
OBJECT-TYPE
The version of RIP that will be used by IP.
1.3.6.1.4.1.173.7.11.1INTEGER {ripVersion1(1), rip1Compatible(2), ripVersion2(3)}read-writemandatory
voice
OBJECT-IDENTITY
1.3.6.1.4.1.173.7.12
voiceSystemVoiceNodeNum
OBJECT-TYPE
The number that identifies this node.
1.3.6.1.4.1.173.7.12.1INTEGER (1..9999)read-writemandatory
voiceSystemRingVolFreq
OBJECT-TYPE
The frequency and voltage of the telephone ring circuit. In two wire OPX mode, the node provides ring voltage to the telephone when it is called by a remote unit.
1.3.6.1.4.1.173.7.12.2INTEGER {v75-hz-16-66(1), v80-hz-20-00(2), v75-hz-25-00(3), v60-hz-50-00(4), v75-hz-50-00(5)}read-writemandatory
voiceSystemCountryCode
OBJECT-TYPE
The telephone dialing prefix code that identifies the country in which the node is installed.
1.3.6.1.4.1.173.7.12.3INTEGER (1..999)read-writemandatory
voiceSystemDialDigits
OBJECT-TYPE
The number of digits that will be used in the speed dialing scheme, as well as the number of digits one can specify for the Auto Dial feature. This requires rebooting for the change to take effect.
1.3.6.1.4.1.173.7.12.4INTEGER (2..4)read-writemandatory
voiceSystemVoiceRatesMin
OBJECT-TYPE
The minimum operating rate of all voice channels when congestion occurs.
1.3.6.1.4.1.173.7.12.5INTEGER {bps-4800(1), bps-8000(2), bps-32000(3), bps-64000(4)}read-writemandatory
voiceSystemVoiceRatesMax
OBJECT-TYPE
The maximum operating digitization rate of all voice channels when there is no congestion.
1.3.6.1.4.1.173.7.12.6INTEGER {bps-4800(1), bps-8000(2), bps-32000(3), bps-64000(4)}read-writemandatory
voiceSystemExtDialDigits
OBJECT-TYPE
The number of extended dial digits that can be defined in the speed map table and/or entered by the user of attached equipment as part of a dial string. This requires rebooting for the change to take effect.
1.3.6.1.4.1.173.7.12.7INTEGER (0..16)read-writemandatory
voiceSpeedDialTable
OBJECT-TYPE
A list of speed-dial numbers.
1.3.6.1.4.1.173.7.12.8not-accessiblemandatory
voiceSpeedDialEntry
OBJECT-TYPE
A Voice Speed Dial entry containing objects relating to the speed-dial number that are configurable by the user.
1.3.6.1.4.1.173.7.12.8.1not-accessiblemandatory
voiceSpeedDialDigits
OBJECT-TYPE
The speed-dial number. A question mark wildcard can be used for any digit, and an asterisk wildcard can be used for any number of digits.
1.3.6.1.4.1.173.7.12.8.1.1OCTET STRING (SIZE(1..4))read-onlymandatory
voiceSpeedDialLongDialMap
OBJECT-TYPE
The number for which the speed-dial number is a shortcut.
1.3.6.1.4.1.173.7.12.8.1.2OCTET STRING (SIZE(6))read-writemandatory
voiceSpeedDialExtDialStr
OBJECT-TYPE
The extended set of digits that will be forwarded with the call if portVoiceOperExtDigitsSource in the physical port record is set to Map.
1.3.6.1.4.1.173.7.12.8.1.3OCTET STRING (SIZE(1..16))read-writemandatory
voiceSpeedDialRowStatus
OBJECT-TYPE
This variable is used to manage the creation and deletion of conceptual rows in the voiceSpeedDialTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned.
1.3.6.1.4.1.173.7.12.8.1.4RowStatusread-writemandatory