NETLINK-SPECIFIC-MIB
- Registered at
- 1.3.6.1.2.1.41.1.2.11.3.6.1.4.1.173
- Namespace
- netlink
- Source file
NETLINK-SPECIFIC-MIB- Digest
sha256:4614fcb779cfceb632824e8421ca96692b1706ef17c98cdbe4df9bbff2752262
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, Gauge32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, enterprises, iso, mgmt, mib-2 |
| SNMPv2-TC | DisplayString, MacAddress, PhysAddress, RowStatus, TEXTUAL-CONVENTION, TimeInterval |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
NETLINK-SPECIFIC-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| NlSubscriberAddress type |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| snaDLC OBJECT-IDENTITY | 1.3.6.1.2.1.41 | |||
| sdlc OBJECT-IDENTITY | 1.3.6.1.2.1.41.1 | |||
| sdlcLSGroup OBJECT-IDENTITY | 1.3.6.1.2.1.41.1.2 | |||
| sdlcLSAdminTable OBJECT-IDENTITY | 1.3.6.1.2.1.41.1.2.1 | |||
| sdlcLSAdminEntry OBJECT-IDENTITY | 1.3.6.1.2.1.41.1.2.1.1 | |||
| sdlcLSAddress OBJECT-TYPE This value is the poll address of the secondary link station for this SDLC link. It uniquely identifies the SDLC link station within a single SDLC port. | 1.3.6.1.2.1.41.1.2.1.1.1 | INTEGER (1..255) | read-only | mandatory |
| netlink OBJECT-IDENTITY | 1.3.6.1.4.1.173 | |||
| network OBJECT-IDENTITY | 1.3.6.1.4.1.173.6 | |||
| netstat OBJECT-IDENTITY | 1.3.6.1.4.1.173.6.1 | |||
| nsMaxNeigh OBJECT-TYPE Maximum number of neighbor nodes. This value is currently always 64 for FRX8000 and 20 for an N7400 or 7500. A neighbor is the closest node in a path from the local node. | 1.3.6.1.4.1.173.6.1.1 | INTEGER | read-only | mandatory |
| nsThisNode OBJECT-TYPE This nodes number. (1-250) | 1.3.6.1.4.1.173.6.1.2 | INTEGER | read-only | mandatory |
| nsNodTable OBJECT-TYPE A table showing all nodes known to this node along with status and neighbor information. | 1.3.6.1.4.1.173.6.1.3 | not-accessible | mandatory | |
| nsEntry OBJECT-TYPE Each entry of the node table is indexed by node number. | 1.3.6.1.4.1.173.6.1.3.1 | not-accessible | mandatory | |
| nsNodNum OBJECT-TYPE The node number of the desired node. This is the index into the node table. | 1.3.6.1.4.1.173.6.1.3.1.1 | INTEGER | read-only | mandatory |
| nsStatus OBJECT-TYPE The operational status of the node. The status is given as: 1 = Node is defined in the database; 9 = Node is operational; | 1.3.6.1.4.1.173.6.1.3.1.2 | INTEGER | read-only | mandatory |
| nsNumNeigh OBJECT-TYPE Current number of neighbor nodes to this node. | 1.3.6.1.4.1.173.6.1.3.1.3 | INTEGER | read-only | mandatory |
| nsNeighTable OBJECT-TYPE The neighbor table lists the status of a nodes neighbors. | 1.3.6.1.4.1.173.6.1.4 | not-accessible | mandatory | |
| nsNeighEntry OBJECT-TYPE The table entries are indexed by the node number and the neighbors node number. | 1.3.6.1.4.1.173.6.1.4.1 | not-accessible | mandatory | |
| nsNTNode OBJECT-TYPE The node number of the node whose neighbor's status is being sought. | 1.3.6.1.4.1.173.6.1.4.1.1 | INTEGER | read-only | mandatory |
| nsNTNeigh OBJECT-TYPE The node number of the neighbor whose status is being sought. | 1.3.6.1.4.1.173.6.1.4.1.2 | INTEGER | read-only | mandatory |
| nsNTNeighStat OBJECT-TYPE The status of the neighbor node given as: 1 = previously, but not currently, connected; 2 = Currently connected; | 1.3.6.1.4.1.173.6.1.4.1.3 | INTEGER {notConnected(1), connected(2)} | read-only | mandatory |
| local OBJECT-IDENTITY | 1.3.6.1.4.1.173.7 | |||
| node OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.1 | |||
| nodeCfgTable OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.1.1 | |||
| nodeAlmTable OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.1.2 | |||
| nodeSNMPGroup OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.1.3 | |||
| nodeModel OBJECT-TYPE Describes the unit model | 1.3.6.1.4.1.173.7.1.3.1 | INTEGER {model1(1), model2(2), rackmount(3), highavail(4), netfrad(5), frx4000(6), ss1800(7)} | read-only | mandatory |
| nodeTrapText OBJECT-TYPE Text of the last alarm generated | 1.3.6.1.4.1.173.7.1.3.2 | DisplayString | read-only | mandatory |
| nodeTrapAdrTable OBJECT-TYPE A table used to define the IP address of end-nodes to receive alarms generated by this node. Up to 16 addresses can be specified. | 1.3.6.1.4.1.173.7.1.3.3 | not-accessible | mandatory | |
| tpAdrEntry OBJECT-TYPE A Trap entry containing objects relating to SNMP traps. | 1.3.6.1.4.1.173.7.1.3.3.1 | not-accessible | mandatory | |
| tpAdrIdx OBJECT-TYPE The index into the trap configuration table | 1.3.6.1.4.1.173.7.1.3.3.1.1 | INTEGER | read-only | mandatory |
| tpAddress OBJECT-TYPE The IP Address of the end-station to send alarms | 1.3.6.1.4.1.173.7.1.3.3.1.2 | IpAddress | read-write | mandatory |
| tpAdrFlag OBJECT-TYPE Defines the state of this entry as: 0 = Do not send traps to the Address; 1 = Send traps to the Address; 2 = This Address entry is deleted from the table; | 1.3.6.1.4.1.173.7.1.3.3.1.3 | INTEGER {disableTraps(1), enableTraps(2), delete(3)} | read-write | mandatory |
| tpAdrSLev OBJECT-TYPE Lowest severity level traps that will be sent to this Address; 1 is the highest, 4 is the lowest. | 1.3.6.1.4.1.173.7.1.3.3.1.4 | INTEGER {critical(1), major(2), minor(3), informational(4)} | read-write | mandatory |
| nodeBagTable OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.1.4 | |||
| hwcard OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.2 | |||
| rlpMaxProtos OBJECT-TYPE Maximum number of protocols allowed on each RLP. This value is currently 11 for FRX4000s, 9 for FRX6000s, and 5 for FRX7000s and FRX8000s. | 1.3.6.1.4.1.173.7.2.1 | INTEGER | read-only | mandatory |
| rlpConfigTable OBJECT-TYPE A Table to describe each RLP on the node | 1.3.6.1.4.1.173.7.2.2 | not-accessible | mandatory | |
| rlpEntry OBJECT-TYPE An RLP entry containing objects relating to RLPs. | 1.3.6.1.4.1.173.7.2.2.1 | not-accessible | mandatory | |
| rlpIndex OBJECT-TYPE The RLP number on the node | 1.3.6.1.4.1.173.7.2.2.1.1 | INTEGER | read-only | mandatory |
| rlpStatus OBJECT-TYPE The current state of this RLP | 1.3.6.1.4.1.173.7.2.2.1.2 | INTEGER {installed(1), configured(2), load-failed(3), loading(4), ipl-failed(5), ipl-in-progress(6), failed(7), operational(8), power-off(9), power-on(10)} | read-only | mandatory |
| rlpMemorySize OBJECT-TYPE The amount of memory installed on this RLP | 1.3.6.1.4.1.173.7.2.2.1.3 | INTEGER | read-only | mandatory |
| rlpLIC1Type OBJECT-TYPE The Type of Line Interface card in the first position | 1.3.6.1.4.1.173.7.2.2.1.4 | INTEGER {none(1), rs232(2), rs422(3), v35(4), hs-rs232(5), x21(6), rs449(7), universal(8), t1(10), e1(11), voice(13)} | read-only | mandatory |
| rlpLIC2Type OBJECT-TYPE The Type of Line Interface card in the second position | 1.3.6.1.4.1.173.7.2.2.1.5 | INTEGER {none(1), rs232(2), rs422(3), v35(4), hs-rs232(5), x21(6), rs449(7), universal(8), t1(10), e1(11), voice(13)} | read-only | mandatory |
| rlpProtocol OBJECT-TYPE The protocols configured on this RLP. This is an OCTET STRING where each octet represents a protocol type. The size of this is the maximum number of protocols allowed on an RLP (rlpMaxProtos). The protocol types are defined as: 00 = none 01 = X.25 02 = Frame Relay 03 = Async 04 = SDLC 05 = BSC Interactive 07 = IP 08 = SNMP 09 = RIP 0A = LLC2 0B = Trunk 0C = IPX 0D = Config 0E = LLC2-R 0F = IP-R 10 = NVSP 11 = Bridge | 1.3.6.1.4.1.173.7.2.2.1.6 | OCTET STRING | read-write | mandatory |
| rlpGroupNumber OBJECT-TYPE The group to which this RLP belongs- always 1 if not FRX7000. | 1.3.6.1.4.1.173.7.2.2.1.7 | INTEGER (1..4) | read-only | mandatory |
| rlpGroupResponsibility OBJECT-TYPE The responsibility of this RLP within its group, always primary if not FRX7000. | 1.3.6.1.4.1.173.7.2.2.1.8 | INTEGER {primary(1), secondary(2)} | read-only | mandatory |
| port OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.3 | |||
| portX25Group OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.3.1 | |||
| portPhyX25AdminTable OBJECT-TYPE This table contains Netlink Enterprise specific objects to manage an X25 port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation. Most of the objects in this read-write table have corresponding read-only objects in the portX25OperTable that return the current operating value. The operating values may be different from these configured values if a configured parameter was configured after the interface was started. | 1.3.6.1.4.1.173.7.3.1.1 | not-accessible | mandatory | |
| portPhyX25AdminEntry OBJECT-TYPE A list of configured values for an X25 port. | 1.3.6.1.4.1.173.7.3.1.1.1 | not-accessible | mandatory | |
| portPhyX25AdminConnector OBJECT-TYPE Physical port interface connector type. | 1.3.6.1.4.1.173.7.3.1.1.1.1 | INTEGER {rs232(3), v35(5), rs449(6), rs530(7), x21(8), t1(10), e1(11)} | read-write | mandatory |
| portPhyX25AdminSpeed OBJECT-TYPE This object defines the speed of the X25 port. The speed may only be set to one of a series of reasonable values, and if an attempt is made to set the speed to a value which is within the valid range but not equal to one of these values, the speed will be rounded up. If the connector type of the port is RS232, the port could be a standard port or a high speed port. If the port is a high speed RS232 port, the maximum valid speed is 256000. If the port is a standard RS232 port, the maximum valid speed is 64000 on the FRX4000/SS1840 and 19200 on all other products. It may be possible to set the speed of a standard RS232 port to a speed which is valid for a high speed RS232 port but invalid for a standard RS232 port. In this case, the port may not end up having the invalid speed. The default speed for a standard RS232 port on the FRX6000 is 19200. | 1.3.6.1.4.1.173.7.3.1.1.1.2 | INTEGER | read-write | mandatory |
| portPhyX25AdminGenerateClock OBJECT-TYPE Specifies whether the port will generate the clock necessary to synchronize traffic over the link. | 1.3.6.1.4.1.173.7.3.1.1.1.3 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portPhyX25AdminRcvClockFromDTE OBJECT-TYPE This object defines whether the receive clock will be used from the DTE. | 1.3.6.1.4.1.173.7.3.1.1.1.4 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portPhyX25AdminDialOut OBJECT-TYPE This flag indicates whether the port is connected to a dial modem, and whethter connections will be initiated through dial-in or dial-out calls. | 1.3.6.1.4.1.173.7.3.1.1.1.5 | INTEGER {none(1), dialIn(2), dialOut(3)} | read-write | mandatory |
| portPhyX25AdminInactivityTimer OBJECT-TYPE This timer defines in minutes, the period of inactivity allowed between calls. Once the timer expires, the port is disabled untill the next call is placed, if a Dial out port, or the Disconnect Timer expires, if a Dial in port. This variable is only meaningful if the port is a Dial port. | 1.3.6.1.4.1.173.7.3.1.1.1.6 | INTEGER (1..30) | read-write | mandatory |
| portPhyX25AdminDisconnectTimer OBJECT-TYPE This timer defines, in seconds, the length of time a dial-in port will remain disabled after expiration of the InActivity Timer. | 1.3.6.1.4.1.173.7.3.1.1.1.7 | INTEGER (1..255) | read-write | mandatory |
| portPhyX25AdminSetupTimer OBJECT-TYPE This timer determines the length of time, in seconds, that a response must be received by the port, after entering the Linkup state. If a response is not received, the port enters a Failed state. | 1.3.6.1.4.1.173.7.3.1.1.1.8 | INTEGER (1..255) | read-write | mandatory |
| portPhyX25AdminTrunkFlag OBJECT-TYPE This flag, when set, indicates the port is associated with a network trunk group. It will be disabled/enabled if the network trunk is not operational. | 1.3.6.1.4.1.173.7.3.1.1.1.9 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portPhyX25AdminTrunkGroup OBJECT-TYPE This variable contains a string of 8 bytes, with each byte indicating 8 ports on an RLP that may be a part of a trunk group. Since a TurboFrad has only 1 RLP, only the first byte is valid if the node is an FRX4000. Each port is represented by a single bit within the RLP byte. The bit position represents the port number...for example, if port 2 on RLP 0 was in a trunk group, the first byte of the string would contain x04 and all other bytes would be 0. | 1.3.6.1.4.1.173.7.3.1.1.1.10 | OCTET STRING | read-write | mandatory |
| portPhyX25AdminRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the portPhyX25AdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device, and which is supplied by a management station wishing to exercise an on-line update of the existing conceptual row. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.3.1.1.1.11 | RowStatus | read-write | mandatory |
| portPhyX25OperTable OBJECT-TYPE This table contains Netlink Enterprise specific objects to manage an X25 port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation. All of the objects in this table are read-only. The operating values may be different from these configured values if a configured parameter was configured after the interface was started. | 1.3.6.1.4.1.173.7.3.1.2 | not-accessible | mandatory | |
| portPhyX25OperEntry OBJECT-TYPE A list of configured values for an X25 port. | 1.3.6.1.4.1.173.7.3.1.2.1 | not-accessible | mandatory | |
| portPhyX25OperConnector OBJECT-TYPE Physical port interface connector type. | 1.3.6.1.4.1.173.7.3.1.2.1.1 | INTEGER {rs232(3), v35(5), rs449(6), rs530(7), x21(8), t1(10), e1(11)} | read-only | mandatory |
| portPhyX25OperSpeed OBJECT-TYPE This object defines the speed of the X25 port. The speed may only be set to one of a series of reasonable values, and if an attempt is made to set the speed to a value which is within the valid range but not equal to one of these values, the speed will be rounded up. If the connector type of the port is RS232, the port could be a standard port or a high speed port. If the port is a high speed RS232 port, the maximum valid speed is 256000. If the port is a standard RS232 port, the maximum valid speed is 64000 on the FRX4000/SS1840 and 19200 on all other products. It may be possible to set the speed of a standard RS232 port to a speed which is valid for a high speed RS232 port but invalid for a standard RS232 port. In this case, the port may not end up having the invalid speed. The default speed for a standard RS232 port on the FRX6000 is 19200. | 1.3.6.1.4.1.173.7.3.1.2.1.2 | INTEGER | read-only | mandatory |
| portPhyX25OperGenerateClock OBJECT-TYPE Specifies whether the port will generate the clock necessary to synchronize traffic over the link. | 1.3.6.1.4.1.173.7.3.1.2.1.3 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portPhyX25OperRcvClockFromDTE OBJECT-TYPE This object defines whether the receive clock will be used from the DTE. | 1.3.6.1.4.1.173.7.3.1.2.1.4 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portPhyX25OperDialOut OBJECT-TYPE This flag indicates whether the port is connected to a dial modem, and whethter connections will be initiated through dial-in or dial-out calls. | 1.3.6.1.4.1.173.7.3.1.2.1.5 | INTEGER {none(1), dialIn(2), dialOut(3)} | read-only | mandatory |
| portPhyX25OperInactivityTimer OBJECT-TYPE This timer defines in minutes, the period of inactivity allowed between calls. Once the timer expires, the port is disabled untill the next call is placed, if a Dial out port, or the Disconnect Timer expires, if a Dial in port. This variable is only meaningful if the port is a Dial port. | 1.3.6.1.4.1.173.7.3.1.2.1.6 | INTEGER (1..30) | read-only | mandatory |
| portPhyX25OperDisconnectTimer OBJECT-TYPE This timer defines, in seconds, the length of time a dial-in port will remain disabled after expiration of the InActivity Timer. | 1.3.6.1.4.1.173.7.3.1.2.1.7 | INTEGER (1..255) | read-only | mandatory |
| portPhyX25OperSetupTimer OBJECT-TYPE This timer determines the length of time, in seconds, that a response must be received by the port, after entering the Linkup state. If a response is not received, the port enters a Failed state. | 1.3.6.1.4.1.173.7.3.1.2.1.8 | INTEGER (1..255) | read-only | mandatory |
| portPhyX25OperTrunkFlag OBJECT-TYPE This flag, when set, indicates the port is associated with a network trunk group. It will be disabled/enabled if the network trunk is not operational. | 1.3.6.1.4.1.173.7.3.1.2.1.9 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portPhyX25OperTrunkGroup OBJECT-TYPE This variable contains a string of 8 bytes, with each byte indicating a port on this RLP that may be a part of a trunk group. | 1.3.6.1.4.1.173.7.3.1.2.1.10 | OCTET STRING | read-only | mandatory |
| portLogicalX25AdminTable OBJECT-TYPE This table contains Netlink Enterprise specific objects to manage an X25 Logical port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation. The operating values may be different from these configured values if a configured parameter was configured after the interface was started. | 1.3.6.1.4.1.173.7.3.1.3 | not-accessible | mandatory | |
| portLogicalX25AdminEntry OBJECT-TYPE A list of configured values for an X25 logical port. | 1.3.6.1.4.1.173.7.3.1.3.1 | not-accessible | mandatory | |
| portLogicalX25AdminFrDlci OBJECT-TYPE The DLCI number used to identify the entry in the table. The range is 16-991. | 1.3.6.1.4.1.173.7.3.1.3.1.1 | INTEGER (16..991) | read-write | mandatory |
| portLogicalX25AdminCxnPriority OBJECT-TYPE This field sets the priority of the connection among others on the physical port. The range is 0 for lowest priority to 9 for the highest priority. | 1.3.6.1.4.1.173.7.3.1.3.1.2 | INTEGER (0..9) | read-write | mandatory |
| portLogicalX25AdminRfc1490 OBJECT-TYPE This field indicates the encapsulation method used | 1.3.6.1.4.1.173.7.3.1.3.1.3 | INTEGER {annexG(1), rfc1490(2)} | read-write | mandatory |
| portLogicalX25AdminBAG OBJECT-TYPE Assigns this DLCI to one of sixteen groups whose parameters regulate bandwidth usage. A 0 value indicates the DLCI does not use BAGs | 1.3.6.1.4.1.173.7.3.1.3.1.4 | INTEGER (0..16) | read-write | mandatory |
| portLogicalX25AdminRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the portLogicalX25AdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device, and which is supplied by a management station wishing to exercise an on-line update of the existing conceptual row. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.3.1.3.1.5 | RowStatus | read-write | mandatory |
| portLogicalX25OperTable OBJECT-TYPE This table contains Netlink Enterprise specific objects to manage an X25 Logical port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation. The operating values may be different from these configured values if a configured parameter was configured after the interface was started. | 1.3.6.1.4.1.173.7.3.1.4 | not-accessible | mandatory | |
| portLogicalX25OperEntry OBJECT-TYPE A list of configured values for an X25 port. | 1.3.6.1.4.1.173.7.3.1.4.1 | not-accessible | mandatory | |
| portLogicalX25OperFrDlci OBJECT-TYPE The DLCI number used to identify the entry in the table. The range is 16-991. | 1.3.6.1.4.1.173.7.3.1.4.1.1 | INTEGER (1..255) | read-only | mandatory |
| portLogicalX25OperCxnPriority OBJECT-TYPE This field sets the priority of the connection among others on the physical port. The range is 0 for lowest priority to 9 for the highest priority. | 1.3.6.1.4.1.173.7.3.1.4.1.2 | INTEGER (0..9) | read-only | mandatory |
| portLogicalX25OperRfc1490 OBJECT-TYPE This field indicates the encapsulation method used | 1.3.6.1.4.1.173.7.3.1.4.1.3 | INTEGER {annexG(1), rfc1490(2)} | read-only | mandatory |
| portLogicalX25OperBAG OBJECT-TYPE Assigns this DLCI to one of sixteen groups whose parameters regulate bandwidth usage. | 1.3.6.1.4.1.173.7.3.1.4.1.4 | INTEGER (1..16) | read-only | mandatory |
| portX25AdminTable OBJECT-TYPE This table contains Netlink Enterprise specific objects to manage an X25 port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation. Most of the objects in this read-write table have corresponding read-only objects in the portX25OperTable that return the current operating value. The operating values may be different from these configured values if a configured parameter was configured after the interface was started. | 1.3.6.1.4.1.173.7.3.1.5 | not-accessible | mandatory | |
| portX25AdminEntry OBJECT-TYPE A list of configured values for an X25 port. | 1.3.6.1.4.1.173.7.3.1.5.1 | not-accessible | mandatory | |
| portX25AdminBlockedFlag OBJECT-TYPE A flag which when set, means the port should not be enabled after a boot-up of the node. | 1.3.6.1.4.1.173.7.3.1.5.1.1 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portX25AdminFlowCtrlNeg OBJECT-TYPE A flag which if set, permits negotiation of the flow control parameters on a per call basis. If N is selected, the default packet and window sizes will be used. If Y is selected, the packet or window size in a call packet (up to the configured Max Packet Size or Max Window Size) is used. | 1.3.6.1.4.1.173.7.3.1.5.1.2 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portX25AdminThruptClassNeg OBJECT-TYPE A flag which ,if set, permists negotiation of the throughput class for either direction of data transmission on a per call basis. If N is selected, the configured Max Throughput Class value is used. If Y, any throughput class in a call packet (up to the Max Thruput Class) is used. | 1.3.6.1.4.1.173.7.3.1.5.1.3 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portX25AdminLocChgPrev OBJECT-TYPE If Y is selected, no calls can be charged to port. Incoming calls from the network with reverse charge specified will be rejected. Outgoing calls will insert reverse charge in the call packet if not already included. | 1.3.6.1.4.1.173.7.3.1.5.1.4 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portX25AdminRevChgAccpt OBJECT-TYPE A flag, if set, that authorizes transmission of incoming calls that request the reverse charge facility. If N is selected, and a call requests it, it will not be transmitted. | 1.3.6.1.4.1.173.7.3.1.5.1.5 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portX25AdminFastSelAccpt OBJECT-TYPE A flag, if set, that authorizes transmission of incoming calls that request the Fast Select facility. | 1.3.6.1.4.1.173.7.3.1.5.1.6 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portX25AdminInCallBar OBJECT-TYPE An X25 facility that prevents transmission of incoming calls to the local DTE. | 1.3.6.1.4.1.173.7.3.1.5.1.7 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portX25AdminOutCallBar OBJECT-TYPE An X25 facility that prevents transmission of incoming calls to the local DTE. | 1.3.6.1.4.1.173.7.3.1.5.1.8 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portX25AdminMaxPktSize OBJECT-TYPE The maximum data packet size that will be allowed to pass through this port. | 1.3.6.1.4.1.173.7.3.1.5.1.9 | INTEGER (128..4096) | read-write | mandatory |
| portX25AdminDefPktSize OBJECT-TYPE This is the size that will be assigned to an incoming call setup packet if the packet does not request a packet size. | 1.3.6.1.4.1.173.7.3.1.5.1.10 | INTEGER (16..4096) | read-write | mandatory |
| portX25AdminMaxWinSize OBJECT-TYPE This is the maximum number of unacknowledged packets per logical channel that can pass through this port. | 1.3.6.1.4.1.173.7.3.1.5.1.11 | INTEGER (2..7) | read-write | mandatory |
| portX25AdminDefWinSize OBJECT-TYPE This size will be assigned to an incoming call setup packet if the packet doesn't request a window size. | 1.3.6.1.4.1.173.7.3.1.5.1.12 | INTEGER (1..7) | read-write | mandatory |
| portX25AdminMaxThruptClass OBJECT-TYPE This specifies the default throughput class that will be inserted into a Call Request packet if Thruput Class negotiation is not enabled or if a thruput class is not requested in the call request. | 1.3.6.1.4.1.173.7.3.1.5.1.13 | INTEGER (3..13) | read-write | mandatory |
| portX25AdminCUGPref OBJECT-TYPE This flag, if set, indicates the port belongs to at least one CUG. | 1.3.6.1.4.1.173.7.3.1.5.1.14 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portX25AdminCUGIndex OBJECT-TYPE This number is an index into a Closed User Group table which identifies the default Closed User Group for the port. | 1.3.6.1.4.1.173.7.3.1.5.1.15 | INTEGER (1..100) | read-write | mandatory |
| portX25AdminCUGIncAccess OBJECT-TYPE This flag, when set, indicates whether this port will be allowed to receive calls from outside its CUGs. | 1.3.6.1.4.1.173.7.3.1.5.1.16 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portX25AdminCUGOutAccess OBJECT-TYPE This flag, when set, indicates whether this port will be allowed to make calls outside its CUGs. | 1.3.6.1.4.1.173.7.3.1.5.1.17 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portX25OperTable OBJECT-TYPE This table contains Netlink Enterprise specific objects to manage an X25 port. Changing one of these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation. The objects in this read-only table corresponding read-only objects in the portX25OperTable that return the current operating value. The operating values may be different from these configured values if a configured parameter was configured after the interface was started. | 1.3.6.1.4.1.173.7.3.1.6 | not-accessible | mandatory | |
| portX25OperEntry OBJECT-TYPE A list of configured values for an X25 port. | 1.3.6.1.4.1.173.7.3.1.6.1 | not-accessible | mandatory | |
| portX25OperBlockedFlag OBJECT-TYPE A flag which when set, means the port should not be enabled after a boot-up of the node. | 1.3.6.1.4.1.173.7.3.1.6.1.1 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portX25OperFlowCtrlNeg OBJECT-TYPE A flag which if set, permits negotiation of the flow control parameters on a per call basis. If N is selected, the default packet and window sizes will be used. If Y is selected, the packet or window size in a call packet (up to the configured Max Packet Size or Max Window Size) is used. | 1.3.6.1.4.1.173.7.3.1.6.1.2 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portX25OperThruptClassNeg OBJECT-TYPE A flag which ,if set, permists negotiation of the throughput class for either direction of data transmission on a per call basis. If N is selected, the configured Max Throughput Class value is used. If Y, any throughput class in a call packet (up to the Max Thruput Class) is used. | 1.3.6.1.4.1.173.7.3.1.6.1.3 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portX25OperLocChgPrev OBJECT-TYPE If Y is selected, no calls can be charged to port. Incoming calls from the network with reverse charge specified will be rejected. Outgoing calls will insert reverse charge in the call packet if not already included. | 1.3.6.1.4.1.173.7.3.1.6.1.4 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portX25OperRevChgAccpt OBJECT-TYPE A flag, if set, that authorizes transmission of incoming calls that request the reverse charge facility. If N is selected, and a call requests it, it will not be transmitted. | 1.3.6.1.4.1.173.7.3.1.6.1.5 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portX25OperFastSelAccpt OBJECT-TYPE A flag, if set, that authorizes transmission of incoming calls that request the Fast Select facility. | 1.3.6.1.4.1.173.7.3.1.6.1.6 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portX25OperInCallBar OBJECT-TYPE An X25 facility that prevents transmission of incoming calls to the local DTE. | 1.3.6.1.4.1.173.7.3.1.6.1.7 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portX25OperOutCallBar OBJECT-TYPE An X25 facility that prevents transmission of incoming calls to the local DTE. | 1.3.6.1.4.1.173.7.3.1.6.1.8 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portX25OperMaxPktSize OBJECT-TYPE The maximum data packet size that will be allowed to pass through this port. | 1.3.6.1.4.1.173.7.3.1.6.1.9 | INTEGER (128..4096) | read-only | mandatory |
| portX25OperDefPktSize OBJECT-TYPE This is the size that will be assigned to an incoming call setup packet if the packet does not request a packet size. | 1.3.6.1.4.1.173.7.3.1.6.1.10 | INTEGER (16..4096) | read-only | mandatory |
| portX25OperMaxWinSize OBJECT-TYPE This is the maximum number of unacknowledged packets per logical channel that can pass through this port. | 1.3.6.1.4.1.173.7.3.1.6.1.11 | INTEGER (2..7) | read-only | mandatory |
| portX25OperDefWinSize OBJECT-TYPE This size will be assigned to an incoming call setup packet if the packet doesn't request a window size. | 1.3.6.1.4.1.173.7.3.1.6.1.12 | INTEGER (1..7) | read-only | mandatory |
| portX25OperMaxThruptClass OBJECT-TYPE This specifies the default throughput class that will be inserted into a Call Request packet if Thruput Class negotiation is not enabled or if a thruput class is not requested in the call request. | 1.3.6.1.4.1.173.7.3.1.6.1.13 | INTEGER (3..13) | read-only | mandatory |
| portX25OperCUGPref OBJECT-TYPE This flag, if set, indicates the port belongs to at least one CUG. | 1.3.6.1.4.1.173.7.3.1.6.1.14 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portX25OperCUGIndex OBJECT-TYPE This number is an index into a Closed User Group table which identifies the default Closed User Group for the port. | 1.3.6.1.4.1.173.7.3.1.6.1.15 | INTEGER (1..100) | read-only | mandatory |
| portX25OperCUGIncAccess OBJECT-TYPE This flag, when set, indicates whether this port will be able to receive calls from outside its CUGs. | 1.3.6.1.4.1.173.7.3.1.6.1.16 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portX25OperCUGOutAccess OBJECT-TYPE This flag, when set, indicates whether this port will be able to make calls outside its CUGs. | 1.3.6.1.4.1.173.7.3.1.6.1.17 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portFrGroup OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.3.2 | |||
| portFrConfigTable OBJECT-TYPE A list of Frame Relay ports . The number of entries will be the number of Frame Relay ports on the node. | 1.3.6.1.4.1.173.7.3.2.1 | not-accessible | mandatory | |
| portFrEntry OBJECT-TYPE An Frame Relay Port entry containing objects relating to the port that are configurable by the user. | 1.3.6.1.4.1.173.7.3.2.1.1 | not-accessible | mandatory | |
| portFrRlpIndex OBJECT-TYPE The RLP number of the Frame Relay port. It will be in the range 1-8. | 1.3.6.1.4.1.173.7.3.2.1.1.1 | INTEGER | read-only | mandatory |
| portFrPortIndex OBJECT-TYPE The Port number of the Frame Relay port. It will be in the range 1-8 for a physical port. It will be in the range 9-64 for a Frame Relay logical port. | 1.3.6.1.4.1.173.7.3.2.1.1.2 | INTEGER | read-only | mandatory |
| portFrBlockedFlag OBJECT-TYPE A flag which when set, means the port should not be enabled after a boot-up of the node. | 1.3.6.1.4.1.173.7.3.2.1.1.3 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portFrMaxBytesPerFrame OBJECT-TYPE The maximum number of bytes allowed in an I Frame for this Frame Relay port. | 1.3.6.1.4.1.173.7.3.2.1.1.4 | INTEGER (16..4096) | read-write | mandatory |
| portFrT392Timer OBJECT-TYPE This timer indicates how long the network will wait between Status Enquiry messages before recording an error. It should be greater than or equal to the frDlcmiPollingInterval variable in the RFC1315 Mib. | 1.3.6.1.4.1.173.7.3.2.1.1.5 | INTEGER (5..30) | read-write | mandatory |
| portFrOutgoingRateControl OBJECT-TYPE This is a flag which, when set, enables the enforcement of the Outgoing Rate Control parameters. | 1.3.6.1.4.1.173.7.3.2.1.1.6 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portFrBandwidthAllocation OBJECT-TYPE This is a flag which, when set, enables whether the bandwidth allocation will be enforced. | 1.3.6.1.4.1.173.7.3.2.1.1.7 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portFrConnector OBJECT-TYPE This defines the connector type of the Frame Relay port. | 1.3.6.1.4.1.173.7.3.2.1.1.8 | INTEGER {rs232(3), v35(5), rs449(6), rs530(7), x21(8), t1(10), e1(11)} | read-write | mandatory |
| portFrLogicalDCE OBJECT-TYPE This defines the port as logical DCE or DTE. | 1.3.6.1.4.1.173.7.3.2.1.1.9 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portFrGenClock OBJECT-TYPE This specifies whether the port will generate the clock necessary to synchronize traffic over the link. | 1.3.6.1.4.1.173.7.3.2.1.1.10 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portFrRcvClkFrmDTE OBJECT-TYPE This allows the clock to be looped back from the DTE using the TT (Terminal Timing) signal, which can be helpful on high-speed lines. | 1.3.6.1.4.1.173.7.3.2.1.1.11 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portFrLLM OBJECT-TYPE This determines whether, and what type of, configurable network management (status enquiries) will be allowed. | 1.3.6.1.4.1.173.7.3.2.1.1.12 | INTEGER {none(1), lmi(2), annexd(3)} | read-write | mandatory |
| portFrRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the portFrConfigTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device, and which is supplied by a management station wishing to exercise an on-line update of the existing conceptual row. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.3.2.1.1.13 | RowStatus | read-write | mandatory |
| portFrSpeed OBJECT-TYPE This object defines the speed of the Frame Relay port. The speed may only be set to one of a series of reasonable values, and if an attempt is made to set the speed to a value which is within the valid range but not equal to one of these values, the speed will be rounded up. If the connector type of the port is RS232, the port could be a standard port or a high speed port. If the port is a high speed RS232 port, the maximum valid speed is 256000. If the port is a standard RS232 port, the maximum valid speed is 64000 on the FRX4000/SS1840 and 19200 on all other products. It may be possible to set the speed of a standard RS232 port to a speed which is valid for a high speed RS232 port but invalid for a standard RS232 port. In this case, the port may not end up having the invalid speed. The default speed for a standard RS232 port on the FRX6000 is 19200. | 1.3.6.1.4.1.173.7.3.2.1.1.14 | INTEGER (75..2048000) | read-write | mandatory |
| portFrBackupUseOnly OBJECT-TYPE This object determines whether all DLCIs on the port will be reserved exclusively as backups for other DLCIs in the same node. If yes is specified for this object, the port will remain disabled until needed for backup. | 1.3.6.1.4.1.173.7.3.2.1.1.15 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portDLCIConfigTable OBJECT-TYPE A list of DLCI's on Frame Relay ports . The number of entries will be the number of DLCIs on all the Frame Relay ports on a node. | 1.3.6.1.4.1.173.7.3.2.2 | not-accessible | mandatory | |
| portDLCIEntry OBJECT-TYPE An Frame Relay Port DLCI entry relating to the Rate Control Information that is configurable by the user. | 1.3.6.1.4.1.173.7.3.2.2.1 | not-accessible | mandatory | |
| portDLCIRlpIndex OBJECT-TYPE The RLP number on which the DLCI is located. The range for this is 1-8. | 1.3.6.1.4.1.173.7.3.2.2.1.1 | INTEGER | read-only | mandatory |
| portDLCIPortIndex OBJECT-TYPE The port number on which the DLCI is located. The range for this is 1-8 for a physical FR port and 9-64 for a logical FR port. | 1.3.6.1.4.1.173.7.3.2.2.1.2 | INTEGER | read-only | mandatory |
| portDLCIIndex OBJECT-TYPE The DLCI number used to identify the entry in the table. The range is 16-991. | 1.3.6.1.4.1.173.7.3.2.2.1.3 | INTEGER | read-only | mandatory |
| portDLCIIncomingCIR OBJECT-TYPE The committed information rate that is supported on the DLCI for incoming data. | 1.3.6.1.4.1.173.7.3.2.2.1.4 | INTEGER (0..2000) | read-write | mandatory |
| portDLCIOutgoingCIR OBJECT-TYPE The committed information rate that is supported on the DLCI for outgoing data. | 1.3.6.1.4.1.173.7.3.2.2.1.5 | INTEGER (0..2000) | read-write | mandatory |
| portDLCIIncomingBc OBJECT-TYPE The committed burst size is the maximum amount of data to be transmitted under normal conditions within the time period defined by Bc/Cir that is supported on the DLCI for incoming data. | 1.3.6.1.4.1.173.7.3.2.2.1.6 | INTEGER | read-write | mandatory |
| portDLCIOutgoingBc OBJECT-TYPE The committed burst size is the maximum amount of data to be transmitted under normal conditions within the time period defined by Bc/Cir that is supported on the DLCI for Outgoing data. | 1.3.6.1.4.1.173.7.3.2.2.1.7 | INTEGER | read-write | mandatory |
| portDLCIIncomingBe OBJECT-TYPE The excess burst size is the maximum amount of incoming data in excess of the committed burst size that the network will try to transfer during the time interval determined by Bc/Cir on this DLCI. | 1.3.6.1.4.1.173.7.3.2.2.1.8 | INTEGER (0..32767) | read-write | mandatory |
| portDLCIOutgoingBe OBJECT-TYPE The excess burst size is the maximum amount of incoming data in excess of the committed burst size that the network will try to transfer during the time interval determined by Bc/Cir on this DLCI. | 1.3.6.1.4.1.173.7.3.2.2.1.9 | INTEGER (0..32767) | read-write | mandatory |
| portDLCIBecnRecoveryCnt OBJECT-TYPE The BECN recovery Count is a method of controlling the rate of return to max traffic flow after it has been reduced due to congestion. The value determines the number of packets received sequentially without BECN set, before increasing the Excess Burst Size by 1/8 of it's configured value. | 1.3.6.1.4.1.173.7.3.2.2.1.10 | INTEGER (0..255) | read-write | mandatory |
| portDLCIPriority OBJECT-TYPE This field sets the priority of the DLCI among others on the physical port. The range is 0 for lowest priority to 4 for the highest priority. | 1.3.6.1.4.1.173.7.3.2.2.1.11 | INTEGER (0..4) | read-write | mandatory |
| portDLCIRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the portDLCIConfigTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. Also note that deleting a DLCI entry will only remove it from the database file, and it's existence will still be known by the protocol until the node is rebooted. | 1.3.6.1.4.1.173.7.3.2.2.1.12 | RowStatus | read-write | mandatory |
| portDLCIBackupGroup OBJECT-TYPE This object specifies (if configured as any number other than zero) that this is a primary DLCI, and identifies the backup DLCI(s) (in a Frame Relay backup group) that will take over if this DLCI fails. This is applicable only on an initiating node, which is the node that will initiate the switchover to a backup DLCI. At switchover, the initiating node notifies the remote node of the change. | 1.3.6.1.4.1.173.7.3.2.2.1.13 | INTEGER | read-write | mandatory |
| portDLCIBackupProtEnb OBJECT-TYPE This object specifies whether the DLCI will be used as a non-initiating backup DLCI. The DLCI will wait for a backup protocol message from the initiating end, telling the backup where to send the rest of the messages. | 1.3.6.1.4.1.173.7.3.2.2.1.14 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portFrBackupGroupTable OBJECT-TYPE A Table describes the Frame Relay Backup MIB . | 1.3.6.1.4.1.173.7.3.2.3 | not-accessible | mandatory | |
| portFrBackupEntry OBJECT-TYPE This Entry contains the SNMP objects that are used for configurating the Frame Relay Backup. | 1.3.6.1.4.1.173.7.3.2.3.1 | not-accessible | mandatory | |
| portFrBackupRLP OBJECT-TYPE This RLP number identifies the RLP containing the primary and backup DLCIs. | 1.3.6.1.4.1.173.7.3.2.3.1.1 | INTEGER (1..8) | read-only | mandatory |
| portFrBackupPort OBJECT-TYPE This Port number is the physical port on which the backup DLCI is being configured. | 1.3.6.1.4.1.173.7.3.2.3.1.2 | INTEGER (1..8) | read-only | mandatory |
| portFrBackupDLCI OBJECT-TYPE This DLCI number is the backup being configured. | 1.3.6.1.4.1.173.7.3.2.3.1.3 | INTEGER (16..991) | read-only | mandatory |
| portFrBackupGroup OBJECT-TYPE This Group number is the backup being configured. | 1.3.6.1.4.1.173.7.3.2.3.1.4 | INTEGER (1..255) | read-only | mandatory |
| portFrBackupWaitTimer OBJECT-TYPE This is the time after a primary DLCI failure that the software will wait for this DLCI to become active before checking the next backup DLCI. If the backup does not become active before the timer expires, the software will search the backup group for the next available backup. | 1.3.6.1.4.1.173.7.3.2.3.1.5 | INTEGER (0..65535) | read-write | mandatory |
| portFrBackupProtEnab OBJECT-TYPE This enables or disables the backup protocol on the specified DLCI. It should be set to yes if and only if the remote device is an FRX4000 or FRX6000 with the backup protocol enabled on the remote DLCI connected to this backup group entry. | 1.3.6.1.4.1.173.7.3.2.3.1.6 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portFrBackupRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the portFrBackupGroupTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.3.2.3.1.7 | RowStatus | read-write | mandatory |
| portBsciGroup OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.3.4 | |||
| portBsciAdminTable OBJECT-TYPE A list of BSC Interactive ports . The number of entries will be the number of BSC Interactive ports on the node. | 1.3.6.1.4.1.173.7.3.4.1 | not-accessible | mandatory | |
| portBsciAdminEntry OBJECT-TYPE A BSCI Interactive Port entry containing objects relating to the port that are configurable by the user. | 1.3.6.1.4.1.173.7.3.4.1.1 | not-accessible | mandatory | |
| portBsciAdminBlockedFlag OBJECT-TYPE Causes the port to be enabled or disabled at node IPL. | 1.3.6.1.4.1.173.7.3.4.1.1.1 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| portBsciAdminConnector OBJECT-TYPE Physical port interface connector type. | 1.3.6.1.4.1.173.7.3.4.1.1.2 | INTEGER {rs232(3), v35(5), rs449(6), rs530(7), x21(8), t1(10)} | read-write | mandatory |
| portBsciAdminSpeed OBJECT-TYPE Data transmission rate in bits per second. | 1.3.6.1.4.1.173.7.3.4.1.1.3 | INTEGER (75..19200) | read-write | mandatory |
| portBsciAdminRetransmitInterval OBJECT-TYPE Length of time before the node will transmit an I-frame if the previous transmission is not acknowledged. | 1.3.6.1.4.1.173.7.3.4.1.1.4 | INTEGER (1..9999) | read-write | mandatory |
| portBsciAdminMAXRetransmits OBJECT-TYPE Maximum number of times the node will attempt to send an I-frame after a retransmission period expiration. | 1.3.6.1.4.1.173.7.3.4.1.1.5 | INTEGER (1..99) | read-write | mandatory |
| portBsciAdminMaxBytesPerFrame OBJECT-TYPE Maximum frame size that will be transmitted on the port. | 1.3.6.1.4.1.173.7.3.4.1.1.6 | INTEGER (25..4105) | read-write | mandatory |
| portBsciAdminGenerateClock OBJECT-TYPE Specifies whether the port will generate the clock necessary to synchronize traffic over the link. | 1.3.6.1.4.1.173.7.3.4.1.1.7 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portBsciAdminRcvClockFromDTE OBJECT-TYPE Allows the clock to be looped back from the DTE using the TT (Terminal Timing) signal. | 1.3.6.1.4.1.173.7.3.4.1.1.8 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portBsciAdminPadType OBJECT-TYPE BSCI Pad Type | 1.3.6.1.4.1.173.7.3.4.1.1.9 | INTEGER {tpad(1), hpad(2)} | read-write | mandatory |
| portBsciAdminUseEBCDIC OBJECT-TYPE Specifies whether all devices on a line use the same character set for successive session polls. | 1.3.6.1.4.1.173.7.3.4.1.1.10 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portBsciAdminCallInfoInRequestPacket OBJECT-TYPE Specifies whether the user will have the option of including call information in a call request packet. | 1.3.6.1.4.1.173.7.3.4.1.1.11 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portBsciAdminClearVCOnLastDeviceDown OBJECT-TYPE Causes the virtual circuit to be cleared when no terminals are using it. | 1.3.6.1.4.1.173.7.3.4.1.1.12 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portBsciAdminTransTextSupported OBJECT-TYPE Causes all characters transmitted to be treated as data. | 1.3.6.1.4.1.173.7.3.4.1.1.13 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portBsciAdminEndToEndAck OBJECT-TYPE Allows management of acknowledgments end to end across the network rather than locally at each end. | 1.3.6.1.4.1.173.7.3.4.1.1.14 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portBsciAdminFullDuplex OBJECT-TYPE Specifies full-duplex transmission. | 1.3.6.1.4.1.173.7.3.4.1.1.15 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portBsciAdminMultidrop OBJECT-TYPE Specifies whether transmission will be multidrop. | 1.3.6.1.4.1.173.7.3.4.1.1.16 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portBsciAdminSlowPollRetryCount OBJECT-TYPE Specifies how many times the control unit will be polled before it is put on the slow poll list. | 1.3.6.1.4.1.173.7.3.4.1.1.17 | INTEGER (10..150) | read-write | mandatory |
| portBsciAdminSlowPollRetryFreq OBJECT-TYPE Specifies the number of times active control units will be polled between pollings on the slow poll list. | 1.3.6.1.4.1.173.7.3.4.1.1.18 | INTEGER (1..200) | read-write | mandatory |
| portBsciAdminStartSynchChars OBJECT-TYPE Specifies the number of synchronization characters that will be added to the beginning of each frame. | 1.3.6.1.4.1.173.7.3.4.1.1.19 | INTEGER (2..10) | read-write | mandatory |
| portBsciAdminEndPadChars OBJECT-TYPE Specifies the number of padding characters that will be added to the end of each frame. | 1.3.6.1.4.1.173.7.3.4.1.1.20 | INTEGER (1..10) | read-write | mandatory |
| portBsciAdminPollInterval OBJECT-TYPE Specifies the time between passes through the polling list. | 1.3.6.1.4.1.173.7.3.4.1.1.21 | INTEGER (100..1000) | read-write | mandatory |
| portBsciAdminNoResponseTimer OBJECT-TYPE Activated after transmission of a general poll or a data frame. | 1.3.6.1.4.1.173.7.3.4.1.1.22 | INTEGER (2..10) | read-write | mandatory |
| portBsciAdminNoResponseRetryCount OBJECT-TYPE Specifies how many times the user device will be polled before control is passed on the next cluster. | 1.3.6.1.4.1.173.7.3.4.1.1.23 | INTEGER (1..255) | read-write | mandatory |
| portBsciAdminErrorRetransmitCount OBJECT-TYPE Specifies the number of times the Netlink device will resend a block of data after the receiving device has detected an error in that block. | 1.3.6.1.4.1.173.7.3.4.1.1.24 | INTEGER (1..255) | read-write | mandatory |
| portBsciAdminNAKRetryCount OBJECT-TYPE Specifies the number of times the Netlink device will send a frame when the receiving device is unable to acknowledge. | 1.3.6.1.4.1.173.7.3.4.1.1.25 | INTEGER (1..255) | read-write | mandatory |
| portBsciAdminBlockCheck OBJECT-TYPE Sets the redundancy check parameter. | 1.3.6.1.4.1.173.7.3.4.1.1.26 | INTEGER {crc16(1), even-lrc(2), odd-lrc(3)} | read-write | mandatory |
| portBsciAdminDataMode OBJECT-TYPE Sets the parity parameter. | 1.3.6.1.4.1.173.7.3.4.1.1.27 | INTEGER {odd-7bit(1), even-7bit(2), none-8bit(3)} | read-write | mandatory |
| portBsciAdminRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the portBsciAdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device, and which is supplied by a management station wishing to exercise an on-line update of the existing conceptual row. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.3.4.1.1.28 | RowStatus | read-write | mandatory |
| portBsciAdminAnswerNonConfigured OBJECT-TYPE Only valid if pad type is HPAD. If yes, the HPAD will respond to all devices on the line. If no, the HPAD will respond only to those devices that are configured on the node. | 1.3.6.1.4.1.173.7.3.4.1.1.29 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portBsciAdminActivateConnectionWithoutPoll OBJECT-TYPE Only valid if pad type is TPAD. If yes, will active the TPAD connection without a poll of the connected device. | 1.3.6.1.4.1.173.7.3.4.1.1.30 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portBsciOperTable OBJECT-TYPE A list of BSC Interactive ports . The number of entries will be the number of BSC Interactive ports on the node. | 1.3.6.1.4.1.173.7.3.4.2 | not-accessible | mandatory | |
| portBsciOperEntry OBJECT-TYPE A BSCI Interactive Port entry containing objects relating to the port that are configurable by the user. | 1.3.6.1.4.1.173.7.3.4.2.1 | not-accessible | mandatory | |
| portBsciOperBlockedFlag OBJECT-TYPE Causes the port to be enabled or disabled at node IPL. | 1.3.6.1.4.1.173.7.3.4.2.1.1 | INTEGER {disabled(1), enabled(2)} | read-only | mandatory |
| portBsciOperConnector OBJECT-TYPE Physical port interface connector type. | 1.3.6.1.4.1.173.7.3.4.2.1.2 | INTEGER {rs232(3), v35(5), rs449(6), rs530(7), x21(8), t1(10)} | read-only | mandatory |
| portBsciOperSpeed OBJECT-TYPE Data transmission rate in bits per second. | 1.3.6.1.4.1.173.7.3.4.2.1.3 | INTEGER | read-only | mandatory |
| portBsciOperRetransmitInterval OBJECT-TYPE Length of time before the node will transmit an I-frame if the previous transmission is not acknowledged. | 1.3.6.1.4.1.173.7.3.4.2.1.4 | INTEGER (1..9999) | read-only | mandatory |
| portBsciOperMAXRetransmits OBJECT-TYPE Maximum number of times the node will attempt to send an I-frame after a retransmission period expiration. | 1.3.6.1.4.1.173.7.3.4.2.1.5 | INTEGER (1..99) | read-only | mandatory |
| portBsciOperMaxBytesPerFrame OBJECT-TYPE Maximum frame size that will be transmitted on the port. | 1.3.6.1.4.1.173.7.3.4.2.1.6 | INTEGER (25..4105) | read-only | mandatory |
| portBsciOperGenerateClock OBJECT-TYPE Specifies whether the port will generate the clock necessary to synchronize traffic over the link. | 1.3.6.1.4.1.173.7.3.4.2.1.7 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portBsciOperRcvClockFromDTE OBJECT-TYPE Allows the clock to be looped back from the DTE using the TT (Terminal Timing) signal. | 1.3.6.1.4.1.173.7.3.4.2.1.8 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portBsciOperPadType OBJECT-TYPE BSCI Pad Type | 1.3.6.1.4.1.173.7.3.4.2.1.9 | INTEGER {tpad(1), hpad(2)} | read-only | mandatory |
| portBsciOperUseEBCDIC OBJECT-TYPE Specifies whether all devices on a line use the same character set for successive session polls. | 1.3.6.1.4.1.173.7.3.4.2.1.10 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portBsciOperCallInfoInRequestPacket OBJECT-TYPE Specifies whether the user will have the option of including call information in a call request packet. | 1.3.6.1.4.1.173.7.3.4.2.1.11 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portBsciOperClearVCOnLastDeviceDown OBJECT-TYPE Causes the virtual circuit to be cleared when no terminals are using it. | 1.3.6.1.4.1.173.7.3.4.2.1.12 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portBsciOperTransTextSupported OBJECT-TYPE Causes all characters transmitted to be treated as data. | 1.3.6.1.4.1.173.7.3.4.2.1.13 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portBsciOperEndToEndAck OBJECT-TYPE Allows management of acknowledgments end to end across the network rather than locally at each end. | 1.3.6.1.4.1.173.7.3.4.2.1.14 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portBsciOperFullDuplex OBJECT-TYPE Specifies full-duplex transmission. | 1.3.6.1.4.1.173.7.3.4.2.1.15 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portBsciOperMultidrop OBJECT-TYPE Specifies whether transmission will be multidrop. | 1.3.6.1.4.1.173.7.3.4.2.1.16 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portBsciOperSlowPollRetryCount OBJECT-TYPE Specifies how many times the control unit will be polled before it is put on the slow poll list. | 1.3.6.1.4.1.173.7.3.4.2.1.17 | INTEGER (10..150) | read-only | mandatory |
| portBsciOperSlowPollRetryFreq OBJECT-TYPE Specifies the number of times active control units will be polled between pollings on the slow poll list. | 1.3.6.1.4.1.173.7.3.4.2.1.18 | INTEGER (1..200) | read-only | mandatory |
| portBsciOperStartSynchChars OBJECT-TYPE Specifies the number of synchronization characters that will be added to the beginning of each frame. | 1.3.6.1.4.1.173.7.3.4.2.1.19 | INTEGER (2..10) | read-only | mandatory |
| portBsciOperEndPadChars OBJECT-TYPE Specifies the number of padding characters that will be added to the end of each frame. | 1.3.6.1.4.1.173.7.3.4.2.1.20 | INTEGER (1..10) | read-only | mandatory |
| portBsciOperPollInterval OBJECT-TYPE Specifies the time between passes through the polling list. | 1.3.6.1.4.1.173.7.3.4.2.1.21 | INTEGER (100..1000) | read-only | mandatory |
| portBsciOperNoResponseTimer OBJECT-TYPE Activated after transmission of a general poll or a data frame. | 1.3.6.1.4.1.173.7.3.4.2.1.22 | INTEGER (2..10) | read-only | mandatory |
| portBsciOperNoResponseRetryCount OBJECT-TYPE Specifies how many times the user device will be polled before control is passed on the next cluster. | 1.3.6.1.4.1.173.7.3.4.2.1.23 | INTEGER (1..255) | read-only | mandatory |
| portBsciOperErrorRetransmitCount OBJECT-TYPE Specifies the number of times the Netlink device will resend a block of data after the receiving device has detected an error in that block. | 1.3.6.1.4.1.173.7.3.4.2.1.24 | INTEGER (1..255) | read-only | mandatory |
| portBsciOperNAKRetryCount OBJECT-TYPE Specifies the number of times the Netlink device will send a frame when the receiving device is unable to acknowledge. | 1.3.6.1.4.1.173.7.3.4.2.1.25 | INTEGER (1..255) | read-only | mandatory |
| portBsciOperBlockCheck OBJECT-TYPE Sets the redundancy check parameter. | 1.3.6.1.4.1.173.7.3.4.2.1.26 | INTEGER {crc16(1), even-lrc(2), odd-lrc(3)} | read-only | mandatory |
| portBsciOperDataMode OBJECT-TYPE Sets the parity parameter. | 1.3.6.1.4.1.173.7.3.4.2.1.27 | INTEGER {odd-7bit(1), even-7bit(2), none-8bit(3)} | read-only | mandatory |
| portBsciOperAnswerNonConfigured OBJECT-TYPE Only valid if pad type is HPAD. If yes, the HPAD will respond to all devices on the line. If no, the HPAD will respond only to those devices that are configured on the node. | 1.3.6.1.4.1.173.7.3.4.2.1.28 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portBsciOperActivateConnectionWithoutPoll OBJECT-TYPE Only valid if pad type is TPAD. If yes, will active the TPAD connection without a poll of the connected device. | 1.3.6.1.4.1.173.7.3.4.2.1.29 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| bsciSubscrAdminTable OBJECT-TYPE A list of BSC Interactive port subscribers. | 1.3.6.1.4.1.173.7.3.4.3 | not-accessible | mandatory | |
| bsciSubscrAdminEntry OBJECT-TYPE A BSCI Interactive Port Subscriber entry containing objects relating to the port that are configurable by the user. | 1.3.6.1.4.1.173.7.3.4.3.1 | not-accessible | mandatory | |
| bsciSubscrAdminSequence OBJECT-TYPE Subscriber index for a specific BSCI port subscriber. | 1.3.6.1.4.1.173.7.3.4.3.1.1 | INTEGER (1..16) | read-only | mandatory |
| bsciSubscrAdminLocalID OBJECT-TYPE Subscriber address of the local end of a BSCI connection. | 1.3.6.1.4.1.173.7.3.4.3.1.2 | NlSubscriberAddress | read-write | mandatory |
| bsciSubscrAdminRemoteID OBJECT-TYPE Subscriber address of the remote end of a BSCI connection. | 1.3.6.1.4.1.173.7.3.4.3.1.3 | NlSubscriberAddress | read-write | mandatory |
| bsciSubscrAdminAutocall OBJECT-TYPE Causes a BSCI TPAD to automatically call its HPAD when the controller becomes active. | 1.3.6.1.4.1.173.7.3.4.3.1.4 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| bsciSubscrAdminAutocallRtyTimer OBJECT-TYPE Time between autocall retries. | 1.3.6.1.4.1.173.7.3.4.3.1.5 | INTEGER (15..255) | read-write | mandatory |
| bsciSubscrAdminAutocallMaxRtry OBJECT-TYPE Maximum number of times an autocall will be sent. | 1.3.6.1.4.1.173.7.3.4.3.1.6 | INTEGER (0..255) | read-write | mandatory |
| bsciSubscrAdminConnectionID OBJECT-TYPE Identifier that will link the BSCI port with a device configured in the BSCI Devices Table. | 1.3.6.1.4.1.173.7.3.4.3.1.7 | INTEGER (0..255) | read-write | mandatory |
| bsciSubscrAdminRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the bsciDevAdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.3.4.3.1.8 | RowStatus | read-write | mandatory |
| bsciSubscrOperTable OBJECT-TYPE A list of BSC Interactive port subscribers. | 1.3.6.1.4.1.173.7.3.4.4 | not-accessible | mandatory | |
| bsciSubscrOperEntry OBJECT-TYPE A BSCI Interactive Port Subscriber entry containing objects relating to the port that are configurable by the user. | 1.3.6.1.4.1.173.7.3.4.4.1 | not-accessible | mandatory | |
| bsciSubscrOperSequence OBJECT-TYPE Subscriber index for a specific BSCI port subscriber. | 1.3.6.1.4.1.173.7.3.4.4.1.1 | INTEGER (1..16) | read-only | mandatory |
| bsciSubscrOperLocalID OBJECT-TYPE Subscriber address of the local end of a BSCI connection. | 1.3.6.1.4.1.173.7.3.4.4.1.2 | NlSubscriberAddress | read-only | mandatory |
| bsciSubscrOperRemoteID OBJECT-TYPE Subscriber address of the remote end of a BSCI connection. | 1.3.6.1.4.1.173.7.3.4.4.1.3 | NlSubscriberAddress | read-only | mandatory |
| bsciSubscrOperAutocall OBJECT-TYPE Causes a BSCI TPAD to automatically call its HPAD when the controller becomes active. | 1.3.6.1.4.1.173.7.3.4.4.1.4 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| bsciSubscrOperAutocallRtyTimer OBJECT-TYPE Time between autocall retries. | 1.3.6.1.4.1.173.7.3.4.4.1.5 | INTEGER (15..255) | read-only | mandatory |
| bsciSubscrOperAutocallMaxRtry OBJECT-TYPE Maximum number of times an autocall will be sent. | 1.3.6.1.4.1.173.7.3.4.4.1.6 | INTEGER (0..255) | read-only | mandatory |
| bsciSubscrOperConnectionID OBJECT-TYPE Identifier that will link the BSCI port with a device configured in the BSCI Devices Table. | 1.3.6.1.4.1.173.7.3.4.4.1.7 | INTEGER (0..255) | read-only | mandatory |
| bsciDevAdminTable OBJECT-TYPE A list of BSC Interactive devices. | 1.3.6.1.4.1.173.7.3.4.5 | not-accessible | mandatory | |
| bsciDevAdminEntry OBJECT-TYPE A BSCI Interactive Device entry containing objects relating to the device that are configurable by the user. | 1.3.6.1.4.1.173.7.3.4.5.1 | not-accessible | mandatory | |
| bsciDevAdminControlUnitID OBJECT-TYPE Control Unit identifier. | 1.3.6.1.4.1.173.7.3.4.5.1.1 | INTEGER (0..31) | read-only | mandatory |
| bsciDevAdminDeviceUnitID OBJECT-TYPE Device Unit identifier. | 1.3.6.1.4.1.173.7.3.4.5.1.2 | INTEGER (0..31) | read-only | mandatory |
| bsciDevAdminConnectionID OBJECT-TYPE The BSCI port connection ID for the device. | 1.3.6.1.4.1.173.7.3.4.5.1.3 | INTEGER (0..255) | read-write | mandatory |
| bsciDevAdminSingleUserVC OBJECT-TYPE Specifies whether each end of the connection is within a same Control Unit/Device Type pair. | 1.3.6.1.4.1.173.7.3.4.5.1.4 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| bsciDevAdminTransTextSupported OBJECT-TYPE Causes all characters transmitted to be treated as data. | 1.3.6.1.4.1.173.7.3.4.5.1.5 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| bsciDevAdminPrinterAttached OBJECT-TYPE Specifies whether the device has a printer attached. | 1.3.6.1.4.1.173.7.3.4.5.1.6 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| bsciDevAdminRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the bsciDevAdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.3.4.5.1.7 | RowStatus | read-write | mandatory |
| bsciDevAdminDisableStatusRequest OBJECT-TYPE Determines how the BSCI port will report the status of the attached device. Normal status- the port will report what the device reports. No status- the port will report status only if the device is active. Always active status- the port will always report the device as active. | 1.3.6.1.4.1.173.7.3.4.5.1.8 | INTEGER {normal(1), none(2), always-active(3)} | read-write | mandatory |
| bsciDevOperTable OBJECT-TYPE A list of BSC Interactive devices. | 1.3.6.1.4.1.173.7.3.4.6 | not-accessible | mandatory | |
| bsciDevOperEntry OBJECT-TYPE A BSCI Interactive Device entry containing objects relating to the device that are configurable by the user. | 1.3.6.1.4.1.173.7.3.4.6.1 | not-accessible | mandatory | |
| bsciDevOperControlUnitID OBJECT-TYPE Control Unit identifier. | 1.3.6.1.4.1.173.7.3.4.6.1.1 | INTEGER (0..31) | read-only | mandatory |
| bsciDevOperDeviceUnitID OBJECT-TYPE Device Unit identifier. | 1.3.6.1.4.1.173.7.3.4.6.1.2 | INTEGER (0..31) | read-only | mandatory |
| bsciDevOperConnectionID OBJECT-TYPE The BSCI port connection ID for the device. | 1.3.6.1.4.1.173.7.3.4.6.1.3 | INTEGER (0..255) | read-only | mandatory |
| bsciDevOperSingleUserVC OBJECT-TYPE Specifies whether each end of the connection is within a same Control Unit/Device Type pair. | 1.3.6.1.4.1.173.7.3.4.6.1.4 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| bsciDevOperTransTextSupported OBJECT-TYPE Causes all characters transmitted to be treated as data. | 1.3.6.1.4.1.173.7.3.4.6.1.5 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| bsciDevOperPrinterAttached OBJECT-TYPE Specifies whether the device has a printer attached. | 1.3.6.1.4.1.173.7.3.4.6.1.6 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| bsciDevOperDisableStatusRequest OBJECT-TYPE Determines how the BSCI port will report the status of the attached device. Normal status- the port will report what the device reports. No status- the port will report status only if the device is active. Always active status- the port will always report the device as active. | 1.3.6.1.4.1.173.7.3.4.6.1.7 | INTEGER {normal(1), none(2), always-active(3)} | read-only | mandatory |
| portSdlcGroup OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.3.5 | |||
| portSdlcAdminTable OBJECT-TYPE This table contains Netlink Enterprise specific objects to manage SDLC port. Changing on of the these parameters may take effect in the operating port immediately or may wait until the interface is restarted depending on the details of the implementation. Most of the objects in this read-write table have corresponding read-only objects in the portSdlcOperTable that return the current operating value. The operating values may be different from these configured values if a configured parameter was configured afterthe interface was started. | 1.3.6.1.4.1.173.7.3.5.1 | not-accessible | mandatory | |
| portSdlcAdminEntry OBJECT-TYPE A list of configured values for an SDLC port. | 1.3.6.1.4.1.173.7.3.5.1.1 | not-accessible | mandatory | |
| portSdlcAdminCommit OBJECT-TYPE Writing a value to this object commits the the SDLC port related modified configuration values to the database. | 1.3.6.1.4.1.173.7.3.5.1.1.1 | INTEGER | read-write | obsolete |
| portSdlcAdminMAXRetries OBJECT-TYPE This object defines the max. number of retries to a non-responding Link station, before putting the Link station to slow-poll list if it is not Normal response Mode OR disconnecting the link station if it is data txfr state. | 1.3.6.1.4.1.173.7.3.5.1.1.2 | INTEGER (0..99) | read-write | mandatory |
| portSdlcAdminMAXOut OBJECT-TYPE This object defines the number of outstanding frames for triggering window full condition. | 1.3.6.1.4.1.173.7.3.5.1.1.3 | INTEGER (1..7) | read-write | mandatory |
| portSdlcAdminPadType OBJECT-TYPE This object defines the SNA PAD types. | 1.3.6.1.4.1.173.7.3.5.1.1.4 | INTEGER {xpad(1), tpad(2), hpad(3), npad(4)} | read-write | mandatory |
| portSdlcAdminGenerateClock OBJECT-TYPE This object defines if the port would generate clock. | 1.3.6.1.4.1.173.7.3.5.1.1.5 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portSdlcAdminRcvClockFromDTE OBJECT-TYPE This object defines if the rcv clock will be used from DTE. | 1.3.6.1.4.1.173.7.3.5.1.1.6 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portSdlcAdminNrz OBJECT-TYPE This object defines the data encoding at the physical layer | 1.3.6.1.4.1.173.7.3.5.1.1.7 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portSdlcAdminPacketSize OBJECT-TYPE This object defines the packet size of the X25 layer used by SNA PAD | 1.3.6.1.4.1.173.7.3.5.1.1.8 | INTEGER (16..4096) | read-write | mandatory |
| portSdlcAdminDisableRequestDisconnect OBJECT-TYPE This object defines if a Request To Disconnect(RD) will be sent when remote PAD clear the connection | 1.3.6.1.4.1.173.7.3.5.1.1.9 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portSdlcAdminLPDASupport OBJECT-TYPE This object defines the type LPDA support on SDLC port. | 1.3.6.1.4.1.173.7.3.5.1.1.10 | INTEGER {none(1), lpda-1(2), lpda-2(3)} | read-write | mandatory |
| portSdlcAdminConnector OBJECT-TYPE This object defines the connector type of the SDLC port. | 1.3.6.1.4.1.173.7.3.5.1.1.11 | INTEGER {rs232(3), v35(5), rs449(6), rs530(7), x21(8), t1(10)} | read-write | mandatory |
| portSdlcAdminSpeed OBJECT-TYPE This object defines the speed of the SDLC port. The speed may only be set to one of a series of reasonable values, and if an attempt is made to set the speed to a value which is within the valid range but not equal to one of these values, the speed will be rounded up. If the connector type of the port is RS232, the port could be a standard port or a high speed port. If the port is a high speed RS232 port, the maximum valid speed is 256000. If the port is a standard RS232 port, the maximum valid speed is 64000 on the FRX4000/SS1840 and 19200 on all other products. It may be possible to set the speed of a standard RS232 port to a speed which is valid for a high speed RS232 port but invalid for a standard RS232 port. In this case, the port may not end up having the invalid speed. The default speed for a standard RS232 port on the FRX6000 is 19200. | 1.3.6.1.4.1.173.7.3.5.1.1.12 | INTEGER (75..2048000) | read-write | mandatory |
| portSdlcAdminRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the portSdlcAdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device, and which is supplied by a management station wishing to exercise an on-line update of the existing conceptual row. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.3.5.1.1.13 | RowStatus | read-write | mandatory |
| portSdlcAdminIdleFillChar OBJECT-TYPE This object specifies a character that wll be inserted into the stream when the SNA link is idle. | 1.3.6.1.4.1.173.7.3.5.1.1.14 | INTEGER {hex-ff(1), hex-7e(2)} | read-write | mandatory |
| portSdlcAdminInactivityTimer OBJECT-TYPE This object determines how long the node will wait with no activity on the port before it will declare the attached device down. | 1.3.6.1.4.1.173.7.3.5.1.1.15 | INTEGER (15..250) | read-write | mandatory |
| portSdlcAdminL1Duplex OBJECT-TYPE This object determines whether level-1 (physical layer) transmission can be in one (half duplex) or both (full duplex) directions at once. | 1.3.6.1.4.1.173.7.3.5.1.1.16 | INTEGER {full-duplex(1), half-duplex(2)} | read-write | mandatory |
| portSdlcOperTable OBJECT-TYPE This table contains current Netlink enterprise specific port parameters | 1.3.6.1.4.1.173.7.3.5.2 | not-accessible | mandatory | |
| portSdlcOperEntry OBJECT-TYPE A list of operational values for an SDLC port. | 1.3.6.1.4.1.173.7.3.5.2.1 | not-accessible | mandatory | |
| portSdlcOperCommit OBJECT-TYPE This object is not used. | 1.3.6.1.4.1.173.7.3.5.2.1.1 | INTEGER | read-only | obsolete |
| portSdlcOperMAXRetries OBJECT-TYPE This object defines the max. number of retries to a non-responding Link station, before putting the Link station to slow-poll list if it is not Normal response Mode OR disconnecting the link station if it is data txfr state. | 1.3.6.1.4.1.173.7.3.5.2.1.2 | INTEGER (0..99) | read-only | mandatory |
| portSdlcOperMAXOut OBJECT-TYPE This object defines the number of outstanding frames for triggering window full condition. | 1.3.6.1.4.1.173.7.3.5.2.1.3 | INTEGER (1..7) | read-only | mandatory |
| portSdlcOperPadType OBJECT-TYPE This object defines the SNA PAD type | 1.3.6.1.4.1.173.7.3.5.2.1.4 | INTEGER {xpad(1), tpad(2), hpad(3), npad(4)} | read-only | mandatory |
| portSdlcOperGenerateClock OBJECT-TYPE This object defines if the port would generate clock. | 1.3.6.1.4.1.173.7.3.5.2.1.5 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portSdlcOperRcvClockFromDTE OBJECT-TYPE This object defines if the rcv clock will be used from DTE. | 1.3.6.1.4.1.173.7.3.5.2.1.6 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portSdlcOperNrz OBJECT-TYPE This object defines the data encoding at the physical layer | 1.3.6.1.4.1.173.7.3.5.2.1.7 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portSdlcOperPacketSize OBJECT-TYPE This object defines the packet size of the X25 layer used by SNA PAD | 1.3.6.1.4.1.173.7.3.5.2.1.8 | INTEGER (16..4096) | read-only | mandatory |
| portSdlcOperDisableRequestDisconnect OBJECT-TYPE This object defines if a Request To Disconnect(RD) will be sent when remote PAD clear the connection | 1.3.6.1.4.1.173.7.3.5.2.1.9 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portSdlcOperLPDASupport OBJECT-TYPE This object defines the type LPDA support on SDLC port. | 1.3.6.1.4.1.173.7.3.5.2.1.10 | INTEGER {none(1), lpda-1(2), lpda-2(3)} | read-only | mandatory |
| portSdlcOperConnector OBJECT-TYPE This object defines the operational connector type of the SDLC port. | 1.3.6.1.4.1.173.7.3.5.2.1.11 | INTEGER {rs232(3), v35(5), rs449(6), rs530(7), x21(8), t1(10)} | read-only | mandatory |
| portSdlcOperSpeed OBJECT-TYPE This object defines the operational speed of the SDLC port. | 1.3.6.1.4.1.173.7.3.5.2.1.12 | INTEGER | read-only | mandatory |
| portSdlcOperIdleFillChar OBJECT-TYPE This object specifies a character that wll be inserted into the stream when the SNA link is idle. | 1.3.6.1.4.1.173.7.3.5.2.1.13 | INTEGER {hex-ff(1), hex-7e(2)} | read-only | mandatory |
| portSdlcOperInactivityTimer OBJECT-TYPE This object determines how long the node will wait with no activity on the port before it will declare the attached device down. | 1.3.6.1.4.1.173.7.3.5.2.1.14 | INTEGER (15..250) | read-only | mandatory |
| portSdlcOperL1Duplex OBJECT-TYPE This object determines whether level-1 (physical layer) transmission can be in one (half duplex) or both (full duplex) directions at once. | 1.3.6.1.4.1.173.7.3.5.2.1.15 | INTEGER {full-duplex(1), half-duplex(2)} | read-only | mandatory |
| lSSdlcAdminTable OBJECT-TYPE This table contains Enterprise specific Link station configurable parameters to manage the link stations. | 1.3.6.1.4.1.173.7.3.5.3 | not-accessible | mandatory | |
| lSSdlcAdminEntry OBJECT-TYPE A list of configured values for an SDLC port. | 1.3.6.1.4.1.173.7.3.5.3.1 | not-accessible | mandatory | |
| lSSdlcAdminLocalSub OBJECT-TYPE This object defines the local subscriber ID of the Link Station | 1.3.6.1.4.1.173.7.3.5.3.1.1 | NlSubscriberAddress | read-write | mandatory |
| lSSdlcAdminRemoteSub OBJECT-TYPE This object defines the remote subscriber ID used to connect to remote Link Station | 1.3.6.1.4.1.173.7.3.5.3.1.2 | NlSubscriberAddress | read-write | mandatory |
| lSSdlcAdminAutoCall OBJECT-TYPE This object defines if auto call is enabled for the link station. If enabled, the link station will initiate connection establishment, when appropriate. Else, it will passively listen to the connection request for establish a connection with the remote PAD | 1.3.6.1.4.1.173.7.3.5.3.1.3 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| lSSdlcAdminRetryTime OBJECT-TYPE This object is used, only when lSSdlcAdminAutoCall object is yes. This defines the time interval measured in seconds in which the connection request is retried | 1.3.6.1.4.1.173.7.3.5.3.1.4 | INTEGER (15..225) | read-write | mandatory |
| lSSdlcAdminRetryCount OBJECT-TYPE This object is used, only when lSSdlcAdminAutoCall object is yes. This defines the number of times the connection initiation is retried before given up. The value of Zero(0) means to try indefinitely | 1.3.6.1.4.1.173.7.3.5.3.1.5 | INTEGER (0..255) | read-write | mandatory |
| lSSdlcAdminLlc2Conversion OBJECT-TYPE This object defines if this link station connects to a LLC2 device/host. | 1.3.6.1.4.1.173.7.3.5.3.1.6 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| lSSdlcAdminLPDAResourceID OBJECT-TYPE This objects the resource ID used during LPDA command support | 1.3.6.1.4.1.173.7.3.5.3.1.7 | INTEGER (0..255) | read-write | mandatory |
| lSSdlcAdminRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the lSSdlcAdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. Also note that deleting a PU entry will only remove it from the database file, and it's existence will still be known by the protocol until the node is rebooted or until an online update of the port is performed. | 1.3.6.1.4.1.173.7.3.5.3.1.8 | RowStatus | read-write | mandatory |
| lSSdlcAdminL2DatMode OBJECT-TYPE This object determines whether transmission can be in one (alternate) or two (simultaneous) directions at the same time. | 1.3.6.1.4.1.173.7.3.5.3.1.9 | INTEGER {two-way-alternate(1), two-way-simultaneous(2)} | read-write | mandatory |
| lSSdlcOperTable OBJECT-TYPE This table contains the operational parameters of the SDLC port | 1.3.6.1.4.1.173.7.3.5.4 | not-accessible | mandatory | |
| lSSdlcOperEntry OBJECT-TYPE A list of configured values for an SDLC port. | 1.3.6.1.4.1.173.7.3.5.4.1 | not-accessible | mandatory | |
| lSSdlcOperLocalSub OBJECT-TYPE This object defines the local subscriber ID of the Link Station | 1.3.6.1.4.1.173.7.3.5.4.1.1 | NlSubscriberAddress | read-only | mandatory |
| lSSdlcOperRemoteSub OBJECT-TYPE This object defines the remote subscriber ID used to connect to remote Link Station | 1.3.6.1.4.1.173.7.3.5.4.1.2 | NlSubscriberAddress | read-only | mandatory |
| lSSdlcOperAutoCall OBJECT-TYPE This object defines if auto call is enabled for the link station. If enabled, the link station will initiate connection establishment, when appropriate. Else, it will passively listen to the connection request for establish a connection with the remote PAD | 1.3.6.1.4.1.173.7.3.5.4.1.3 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| lSSdlcOperRetryTime OBJECT-TYPE This object is valid, only when lSSdlcAdminAutoCall object is yes. This defines the time interval measured in seconds in which the connection request is retried | 1.3.6.1.4.1.173.7.3.5.4.1.4 | INTEGER (15..225) | read-only | mandatory |
| lSSdlcOperRetryCount OBJECT-TYPE This object is used, only when lSSdlcAdminAutoCall object is yes. This defines the number of times the connection initiation is retried before given up. The value of Zero(0) means to try indefinitely | 1.3.6.1.4.1.173.7.3.5.4.1.5 | INTEGER (0..255) | read-only | mandatory |
| lSSdlcOperLlc2Conversion OBJECT-TYPE This object defines if this link station connects to a LLC2 device/host. | 1.3.6.1.4.1.173.7.3.5.4.1.6 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| lSSdlcOperLPDAResourceID OBJECT-TYPE This objects the resource ID used during LPDA command support | 1.3.6.1.4.1.173.7.3.5.4.1.7 | INTEGER (0..255) | read-only | mandatory |
| lSSdlcOperL2DatMode OBJECT-TYPE This object determines whether transmission can be in one (alternate) or two (simultaneous) directions at the same time. | 1.3.6.1.4.1.173.7.3.5.4.1.8 | INTEGER {two-way-alternate(1), two-way-simultaneous(2)} | read-only | mandatory |
| lSSdlcLlc2AdminTable OBJECT-TYPE This table contains the LLC2 related parameters used to configure LLC2 session, when the SDLC station is connected to a LLC2 device at the remote end | 1.3.6.1.4.1.173.7.3.5.5 | not-accessible | mandatory | |
| lSSdlcLlc2AdminEntry OBJECT-TYPE A list of configured values for an SDLC port. | 1.3.6.1.4.1.173.7.3.5.5.1 | not-accessible | mandatory | |
| lSSdlcLlc2AdminLocalSap OBJECT-TYPE This object defines Local SAP address (multiple of 4) | 1.3.6.1.4.1.173.7.3.5.5.1.1 | INTEGER (0..252) | read-write | mandatory |
| lSSdlcLlc2AdminLocalMac OBJECT-TYPE This object defines the local MAC address | 1.3.6.1.4.1.173.7.3.5.5.1.2 | PhysAddress | read-write | mandatory |
| lSSdlcLlc2AdminIdblk OBJECT-TYPE This object defines idblk used in XID | 1.3.6.1.4.1.173.7.3.5.5.1.3 | INTEGER (0..4095) | read-write | mandatory |
| lSSdlcLlc2AdminIdnum OBJECT-TYPE This object defines idnum used in XID | 1.3.6.1.4.1.173.7.3.5.5.1.4 | INTEGER (0..1048575) | read-write | mandatory |
| lSSdlcLlc2AdminLanTi OBJECT-TYPE This object defines LLC2 inactivity timer measured in units of seconds | 1.3.6.1.4.1.173.7.3.5.5.1.5 | INTEGER (1..50) | read-write | mandatory |
| lSSdlcLlc2AdminLanT1 OBJECT-TYPE This object defines LLC2 reply timer measured in units of 100 milliseconds | 1.3.6.1.4.1.173.7.3.5.5.1.6 | INTEGER (1..250) | read-write | mandatory |
| lSSdlcLlc2AdminLanT2 OBJECT-TYPE This object defines Receiver Ack Timer measured in units of milliseconds | 1.3.6.1.4.1.173.7.3.5.5.1.7 | INTEGER (100..5000) | read-write | mandatory |
| lSSdlcLlc2AdminLanN2 OBJECT-TYPE This object defines Maximum Retransmissions | 1.3.6.1.4.1.173.7.3.5.5.1.8 | INTEGER (0..255) | read-write | mandatory |
| lSSdlcLlc2AdminLanN3 OBJECT-TYPE This object defines count of I-format LPDU's before sending Ack | 1.3.6.1.4.1.173.7.3.5.5.1.9 | INTEGER (1..127) | read-write | mandatory |
| lSSdlcLlc2AdminLanTw OBJECT-TYPE This object defines Outstanding Frames | 1.3.6.1.4.1.173.7.3.5.5.1.10 | INTEGER (1..127) | read-write | mandatory |
| lSSdlcLlc2AdminBAG OBJECT-TYPE This object defines bandwidth allocation group | 1.3.6.1.4.1.173.7.3.5.5.1.11 | INTEGER (0..16) | read-write | mandatory |
| lSSdlcLlc2AdminPriority OBJECT-TYPE This object defines priority for traffic within the node | 1.3.6.1.4.1.173.7.3.5.5.1.12 | INTEGER (0..9) | read-write | mandatory |
| lSSdlcLlc2AdminRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the lSSdlcLlc2AdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. Also note that deleting a PU entry will only remove it from the database file, and it's existence will still be known by the protocol until the node is rebooted or until an online update of the port is performed. | 1.3.6.1.4.1.173.7.3.5.5.1.13 | RowStatus | read-write | mandatory |
| lSSdlcLlc2AdminSuppressXID OBJECT-TYPE This object prevents (if yes) the returning of an XID in response to a null XID. This might be desirable if the remote TPAD is not running PU 2.1. It should be noted that even if an XID is sent, an SNRM (Set Normal Response Mode) immediately follows, so the connection will be established. | 1.3.6.1.4.1.173.7.3.5.5.1.14 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| lSSdlcLlc2OperTable OBJECT-TYPE This table contains operartional parameters related to LLC2 session of this link station. | 1.3.6.1.4.1.173.7.3.5.6 | not-accessible | mandatory | |
| lSSdlcLlc2OperEntry OBJECT-TYPE A list of configured values for an SDLC port. | 1.3.6.1.4.1.173.7.3.5.6.1 | not-accessible | mandatory | |
| lSSdlcLlc2OperLocalSap OBJECT-TYPE This object defines Local SAP address (multiple of 4) | 1.3.6.1.4.1.173.7.3.5.6.1.1 | INTEGER (0..252) | read-only | mandatory |
| lSSdlcLlc2OperLocalMac OBJECT-TYPE This object defines the local MAC address | 1.3.6.1.4.1.173.7.3.5.6.1.2 | PhysAddress | read-only | mandatory |
| lSSdlcLlc2OperIdblk OBJECT-TYPE This object defines idblk used in XID | 1.3.6.1.4.1.173.7.3.5.6.1.3 | INTEGER (0..4095) | read-only | mandatory |
| lSSdlcLlc2OperIdnum OBJECT-TYPE This object defines idnum used in XID | 1.3.6.1.4.1.173.7.3.5.6.1.4 | INTEGER (0..1048575) | read-only | mandatory |
| lSSdlcLlc2OperLanTi OBJECT-TYPE This object defines LLC2 inactivity timer measured in units of seconds | 1.3.6.1.4.1.173.7.3.5.6.1.5 | INTEGER (1..50) | read-only | mandatory |
| lSSdlcLlc2OperLanT1 OBJECT-TYPE This object defines LLC2 reply timer measured in units of 100 milliseconds | 1.3.6.1.4.1.173.7.3.5.6.1.6 | INTEGER (1..250) | read-only | mandatory |
| lSSdlcLlc2OperLanT2 OBJECT-TYPE This object defines Receiver Ack Timer measured in units of milliseconds | 1.3.6.1.4.1.173.7.3.5.6.1.7 | INTEGER (100..5000) | read-only | mandatory |
| lSSdlcLlc2OperLanN2 OBJECT-TYPE This object defines Maximum Retransmissions | 1.3.6.1.4.1.173.7.3.5.6.1.8 | INTEGER (0..255) | read-only | mandatory |
| lSSdlcLlc2OperLanN3 OBJECT-TYPE This object defines count of I-format LPDU's before sending Ack | 1.3.6.1.4.1.173.7.3.5.6.1.9 | INTEGER (1..127) | read-only | mandatory |
| lSSdlcLlc2OperLanTw OBJECT-TYPE This object defines Outstanding Frames | 1.3.6.1.4.1.173.7.3.5.6.1.10 | INTEGER (1..127) | read-only | mandatory |
| lSSdlcLlc2OperBAG OBJECT-TYPE This object defines bandwidth allocation group | 1.3.6.1.4.1.173.7.3.5.6.1.11 | INTEGER (0..16) | read-only | mandatory |
| lSSdlcLlc2OperPriority OBJECT-TYPE This object defines priority for traffic within the node | 1.3.6.1.4.1.173.7.3.5.6.1.12 | INTEGER (0..9) | read-only | mandatory |
| lSSdlcLlc2OperSuppressXID OBJECT-TYPE This object prevents (if yes) the returning of an XID in response to a null XID. This might be desirable if the remote TPAD is not running PU 2.1. It should be noted that even if an XID is sent, an SNRM (Set Normal Response Mode) immediately follows, so the connection will be established. | 1.3.6.1.4.1.173.7.3.5.6.1.13 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portT1Group OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.3.7 | |||
| portT1AdminTable OBJECT-TYPE The configuration information pertaining to a T1 port. T1 ports can operate at full T1 bandwidth or DS0A channelized which provides 24 separate channels. | 1.3.6.1.4.1.173.7.3.7.1 | not-accessible | mandatory | |
| portT1AdminEntry OBJECT-TYPE A T1 port entry containing objects relating to T1 ports. | 1.3.6.1.4.1.173.7.3.7.1.1 | not-accessible | mandatory | |
| portT1AdminBlockedPortFlag OBJECT-TYPE | 1.3.6.1.4.1.173.7.3.7.1.1.1 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portT1AdminGenerateClock OBJECT-TYPE | 1.3.6.1.4.1.173.7.3.7.1.1.2 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portT1AdminFramingMode OBJECT-TYPE Specifies how this T1 port is to function. ds0AT1 specifies a 24 channelized T1. | 1.3.6.1.4.1.173.7.3.7.1.1.3 | INTEGER {fullT1(1), ds0aT1(2)} | read-write | mandatory |
| portT1AdminFrameModelSelect OBJECT-TYPE | 1.3.6.1.4.1.173.7.3.7.1.1.4 | INTEGER {d4(1), esf(2)} | read-write | mandatory |
| portT1AdminLineEncoding OBJECT-TYPE | 1.3.6.1.4.1.173.7.3.7.1.1.5 | INTEGER {b8zs(1), ami(2)} | read-write | mandatory |
| portT1AdminLineBuildOut OBJECT-TYPE | 1.3.6.1.4.1.173.7.3.7.1.1.6 | INTEGER {zerodb(1), x133-266ft(2), x266-399ft(3), x399-533ft(4), x533-655ft(5), minus7p5db(6), minus15db(7), minus22p5db(8)} | read-write | mandatory |
| portT1AdminRowStatus OBJECT-TYPE | 1.3.6.1.4.1.173.7.3.7.1.1.7 | RowStatus | read-write | mandatory |
| portT1AdminProtocolFraming OBJECT-TYPE | 1.3.6.1.4.1.173.7.3.7.1.1.8 | INTEGER {sync(1), bisync(2)} | read-write | mandatory |
| portT1AdminNRZI OBJECT-TYPE | 1.3.6.1.4.1.173.7.3.7.1.1.9 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portT1OperTable OBJECT-TYPE The configuration information pertaining to a T1 port. T1 ports can operate at full T1 bandwidth or DS0A channelized which provides 24 separate channels. | 1.3.6.1.4.1.173.7.3.7.2 | not-accessible | mandatory | |
| portT1OperEntry OBJECT-TYPE A T1 port entry containing objects relating to T1 ports. | 1.3.6.1.4.1.173.7.3.7.2.1 | not-accessible | mandatory | |
| portT1OperBlockedPortFlag OBJECT-TYPE | 1.3.6.1.4.1.173.7.3.7.2.1.1 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portT1OperGenerateClock OBJECT-TYPE | 1.3.6.1.4.1.173.7.3.7.2.1.2 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portT1OperFramingMode OBJECT-TYPE Specifies how this T1 port is to function. ds0AT1 specifies a 24 channelized T1. | 1.3.6.1.4.1.173.7.3.7.2.1.3 | INTEGER {fullT1(1), ds0aT1(2)} | read-only | mandatory |
| portT1OperFrameModelSelect OBJECT-TYPE | 1.3.6.1.4.1.173.7.3.7.2.1.4 | INTEGER {d4(1), esf(2)} | read-only | mandatory |
| portT1OperLineEncoding OBJECT-TYPE | 1.3.6.1.4.1.173.7.3.7.2.1.5 | INTEGER {b8zs(1), ami(2)} | read-only | mandatory |
| portT1OperLineBuildOut OBJECT-TYPE | 1.3.6.1.4.1.173.7.3.7.2.1.6 | INTEGER {zerodb(1), x133-266ft(2), x266-399ft(3), x399-533ft(4), x533-655ft(5), minus7p5db(6), minus15db(7), minus22p5db(8)} | read-only | mandatory |
| portT1OperProtocolFraming OBJECT-TYPE | 1.3.6.1.4.1.173.7.3.7.2.1.7 | INTEGER {sync(1), bisync(2)} | read-only | mandatory |
| portT1OperNRZI OBJECT-TYPE | 1.3.6.1.4.1.173.7.3.7.2.1.8 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portVoiceGroup OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.3.8 | |||
| portVoiceAdminTable OBJECT-TYPE A list of Voice ports. The number of entries will be the number of Voice ports on the node. | 1.3.6.1.4.1.173.7.3.8.1 | not-accessible | mandatory | |
| portVoiceAdminEntry OBJECT-TYPE A Voice Port entry containing objects relating to the port that are configurable by the user. | 1.3.6.1.4.1.173.7.3.8.1.1 | not-accessible | mandatory | |
| portVoiceAdminRlpIndex OBJECT-TYPE The RLP number of the Voice port. | 1.3.6.1.4.1.173.7.3.8.1.1.1 | INTEGER | read-only | mandatory |
| portVoiceAdminPortIndex OBJECT-TYPE The Port number of the Voice port. | 1.3.6.1.4.1.173.7.3.8.1.1.2 | INTEGER | read-only | mandatory |
| portVoiceAdminBlockedFlag OBJECT-TYPE The flag which causes the port to be enabled or disabled at node IPL. The port will remain in that state until this flag is changed and the node is rebooted, or until an on- line enable or disable is performed. | 1.3.6.1.4.1.173.7.3.8.1.1.3 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| portVoiceAdminSpeed OBJECT-TYPE The speed of the port which is transmitted as part of a Call Setup frame. A Voice call will be established if there is enough bandwidth at each end to provide the minimum configured rate. | 1.3.6.1.4.1.173.7.3.8.1.1.4 | INTEGER {bps-4800(1), bps-8000(2), bps-32000(3), bps-64000(4)} | read-write | mandatory |
| portVoiceAdminDTMF OBJECT-TYPE The flag to enable, disable, or specify a time span over which DTMF (Dual Tone Multi Frequency) tones will be regenerated. 0 = pass tones transparently to the remote device. 1 = detect incoming tones and regenerate as received. 2-255 = regenerate tones for the specified seconds. | 1.3.6.1.4.1.173.7.3.8.1.1.5 | INTEGER (0..255) | read-write | mandatory |
| portVoiceAdminInterface OBJECT-TYPE The type of interface (in conjunction with the Telephony Interface Type) that will be used by the Voice channel. This requires rebooting for the change to take effect. Telephony Type Interface Type -------------- -------------- OPX (FXO) Loop Start SLT (FXS) Loop Start E&M 4W E&M, 4W E&M TE, 2W E&M, 2W E&M TE AC15 AC15A, AC15C | 1.3.6.1.4.1.173.7.3.8.1.1.6 | INTEGER {em-4w(1), em-2w(2), loop-start(3), ac15-a(4), ac15-b(6), em-4w-te(10), em-2w-te(11)} | read-write | mandatory |
| portVoiceAdminTETimer OBJECT-TYPE The delay at which the E&M 'E' lead follows the 'M' lead. | 1.3.6.1.4.1.173.7.3.8.1.1.7 | INTEGER (0..255) | read-write | mandatory |
| portVoiceAdminLevelIn OBJECT-TYPE The local voice level into the voice port. This adjusts the sensitivity of the local voice channel to the signal from the attached device. The purpose of this is to match the voice channel dB level to the input signal. A more negative setting produces a higher input gain. If the level is reduced, the voice channel will be more sensitive to the input. This will also cause the voice output at the remote device to sound louder. | 1.3.6.1.4.1.173.7.3.8.1.1.8 | INTEGER (-22..7) | read-write | mandatory |
| portVoiceAdminLevelOut OBJECT-TYPE The local voice level out of the voice port. A more positive setting produces a higher volume. | 1.3.6.1.4.1.173.7.3.8.1.1.9 | INTEGER (-22..7) | read-write | mandatory |
| portVoiceAdminCallTimer OBJECT-TYPE The amount of time the node will wait for a response to a Call Connect or Call Clear request. When the node issues a request, it will set a timer to the value configured here. If that timer expires with no response from the destination, the node will generate a busy tone. | 1.3.6.1.4.1.173.7.3.8.1.1.10 | INTEGER (1..30) | read-write | mandatory |
| portVoiceAdminHuntGroup OBJECT-TYPE The hunt group that includes the voice channel. | 1.3.6.1.4.1.173.7.3.8.1.1.11 | INTEGER {none(1), a(2), b(3)} | read-write | mandatory |
| portVoiceAdminLongDialPrefix OBJECT-TYPE The character that will be required preceeding calls using the long call format. When the user at an attached device dials a long form number, it must be preceeded by the prefix character specified here. | 1.3.6.1.4.1.173.7.3.8.1.1.12 | OCTET STRING (SIZE(1)) | read-write | mandatory |
| portVoiceAdminSLTTimeout OBJECT-TYPE The time the local port will wait before an actual fax transmission begins. If there is no fax tone when this timer expires, the connection will be terminated. | 1.3.6.1.4.1.173.7.3.8.1.1.13 | INTEGER (1..99) | read-write | mandatory |
| portVoiceAdminLinkDownBusy OBJECT-TYPE This flag enables or disables automatic busy-out of channels when the link is down. When enabled, the system will automatically busy-out channels when the composite link is down. When disabled, channels remain on-hook when the link is down. If your application is connected to a PBX that can route calls to another alternate source based on an all busy condition, enable this so the PBX will recognize this condition and reroute the calls while the composite link is down. | 1.3.6.1.4.1.173.7.3.8.1.1.14 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| portVoiceAdminFaxSupported OBJECT-TYPE The flag to indicate whether or not faxes will be transmitted on the port. If no, all calls will be treated as voice. If yes, both voice and fax will be transmitted. | 1.3.6.1.4.1.173.7.3.8.1.1.15 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| portVoiceAdminTelephonyType OBJECT-TYPE The type of interface (in conjunction with the Interface Type) that will be used by the Voice channel. This requires rebooting for the change to take effect. Telephony Type Interface Type -------------- -------------- OPX (FXO) Loop Start SLT (FXS) Loop Start E&M 4W E&M, 4W E&M TE, 2W E&M, 2W E&M TE AC15 AC15A, AC15C | 1.3.6.1.4.1.173.7.3.8.1.1.16 | INTEGER {opx(1), slt(2), em(3), ac15(4)} | read-write | mandatory |
| portVoiceAdminJitter OBJECT-TYPE The amount of jitter delay. | 1.3.6.1.4.1.173.7.3.8.1.1.17 | INTEGER (10..255) | read-write | mandatory |
| portVoiceAdminSampleDelay OBJECT-TYPE The amount of sample delay. | 1.3.6.1.4.1.173.7.3.8.1.1.18 | INTEGER (0..255) | read-write | mandatory |
| portVoiceAdminDialTimer OBJECT-TYPE The delay the node will use to determine when variable length dialing is complete. (Variable length dialing allows the user to place a call without entering the configured number of digits for the speed dial number.) | 1.3.6.1.4.1.173.7.3.8.1.1.19 | INTEGER (0..10) | read-write | mandatory |
| portVoiceAdminAutoDial OBJECT-TYPE The flag to enable or disable the auto dial feature. Note that enabling this feature will disable the variable length dialing feature for this channel. | 1.3.6.1.4.1.173.7.3.8.1.1.20 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| portVoiceAdminSuppression OBJECT-TYPE The silence suppression level. A larger silence suppression level allows more data channels to operate simultaneously with the voice channels. | 1.3.6.1.4.1.173.7.3.8.1.1.21 | INTEGER {very-low(1), low(2), medium(3), high(4), very-high(5)} | read-write | mandatory |
| portVoiceAdminAutoDialNumber OBJECT-TYPE The number to which the node will attempt to connect when the handset attached to this port is taken off-hook. This is applicable only when the Auto Dial feature is enabled. | 1.3.6.1.4.1.173.7.3.8.1.1.22 | OCTET STRING (SIZE(0..4)) | read-write | mandatory |
| portVoiceAdminAutoPoll OBJECT-TYPE The flag to enable or disable auto polling. This is applicable only when the Auto Dial feature is enabled. When enabled, the node periodically polls the destination. If the poll is not acknowledged, the node will busy-out the channel. This can be useful in situations where the destination is an emergency number that must always be available. If the destination does not answer the automatic poll, the busy-out condition will notify an attached PBX that the emergency call should be routed to another call routing device. | 1.3.6.1.4.1.173.7.3.8.1.1.23 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| portVoiceAdminAutoPollTimer OBJECT-TYPE The frequency with which an Auto Poll will be sent. This is applicable only when auto poll is enabled. | 1.3.6.1.4.1.173.7.3.8.1.1.24 | INTEGER (5..30) | read-write | mandatory |
| portVoiceAdminExtDigitsSource OBJECT-TYPE The source of the extended digits when the user of attached equipment dials a speed dial number. This is applicable only when the number of extended dial digits is greater than zero. When map is specified, extended digits are taken from the extended digits field in the map table. When user is specified, extended digits are taken from the user of attached equipment. | 1.3.6.1.4.1.173.7.3.8.1.1.25 | INTEGER {map(1), user(2)} | read-write | mandatory |
| portVoiceAdminNumDigitsDelete OBJECT-TYPE The number of leading dial digits that will be deleted before a dial string is forwarded. This is primarily used to delete leading dial digits that may be inserted by an attached PBX. | 1.3.6.1.4.1.173.7.3.8.1.1.26 | INTEGER (0..4) | read-write | mandatory |
| portVoiceAdminForwardDelay OBJECT-TYPE The length of a pause that can be inserted in an extended dial string that is being forwarded. This is applicable only when forwarded output digits is all or extended. When a comma is encountered in an extended digits string, the node will pause for the length of time specified here before additional extended digits are forwarded. | 1.3.6.1.4.1.173.7.3.8.1.1.27 | INTEGER (0..40) | read-write | mandatory |
| portVoiceAdminForwardedType OBJECT-TYPE The method how the dial digits will be forwarded. This is applicable only when forwarded output digits is all or extended. | 1.3.6.1.4.1.173.7.3.8.1.1.28 | INTEGER {dtmf(1), pulse(2)} | read-write | mandatory |
| portVoiceAdminForwardedDigits OBJECT-TYPE The flag indicating which dial digits, if any, to forward. If none, dial digits are not forwarded to the destination device when a call is initiated on this channel. If all, the dialed speed dial number and associated extended digits are forwarded to the destination device. If extended, only the extended digit string is forwarded. | 1.3.6.1.4.1.173.7.3.8.1.1.29 | INTEGER {none(1), all(2), extended(3)} | read-write | mandatory |
| portVoiceAdminMakeRatio OBJECT-TYPE The make ratio of each digit pulse that is forwarded. This is applicable only when forwarded output digits is all or extended and forwarded digit type is pulse. | 1.3.6.1.4.1.173.7.3.8.1.1.30 | INTEGER (20..80) | read-write | mandatory |
| portVoiceAdminBreakRatio OBJECT-TYPE The break ratio of each digit pulse that is forwarded. This is applicable only when forwarded output digits is all or extended and forwarded digit type is pulse. | 1.3.6.1.4.1.173.7.3.8.1.1.31 | INTEGER (20..80) | read-write | mandatory |
| portVoiceAdminDTMFOnDuration OBJECT-TYPE The length of a tone that will be used to produce a single DTMF digit. This is applicable only when forwarded output digits is all or extended and forwarded digit type is DTMF. | 1.3.6.1.4.1.173.7.3.8.1.1.32 | INTEGER (30..1000) | read-write | mandatory |
| portVoiceAdminDTMFOffDuration OBJECT-TYPE The length of silence between DTMF tones in a dial digit string. This is applicable only when forwarded output digits is all or extended and forwarded digit type is DTMF. | 1.3.6.1.4.1.173.7.3.8.1.1.33 | INTEGER (30..1000) | read-write | mandatory |
| portVoiceAdminToneType OBJECT-TYPE The tone type to detect/regenerate for forwarding DTMF/MF. | 1.3.6.1.4.1.173.7.3.8.1.1.34 | INTEGER {dtmf(1), mf(2)} | read-write | mandatory |
| portVoiceAdminRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the portVoiceAdminTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device, and which is supplied by a management station wishing to exercise an on-line update of the existing conceptual row. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.3.8.1.1.35 | RowStatus | read-write | mandatory |
| portVoiceOperTable OBJECT-TYPE A list of Voice ports. The number of entries will be the number of Voice ports on the node. | 1.3.6.1.4.1.173.7.3.8.2 | not-accessible | mandatory | |
| portVoiceOperEntry OBJECT-TYPE A Voice Port entry containing objects relating to the port that are configurable by the user. | 1.3.6.1.4.1.173.7.3.8.2.1 | not-accessible | mandatory | |
| portVoiceOperRlpIndex OBJECT-TYPE The RLP number of the Voice port. | 1.3.6.1.4.1.173.7.3.8.2.1.1 | INTEGER | read-only | mandatory |
| portVoiceOperPortIndex OBJECT-TYPE The Port number of the Voice port. | 1.3.6.1.4.1.173.7.3.8.2.1.2 | INTEGER | read-only | mandatory |
| portVoiceOperBlockedFlag OBJECT-TYPE The flag which causes the port to be enabled or disabled at node IPL. The port will remain in that state until this flag is changed and the node is rebooted, or until an on- line enable or disable is performed. | 1.3.6.1.4.1.173.7.3.8.2.1.3 | INTEGER {disabled(1), enabled(2)} | read-only | mandatory |
| portVoiceOperSpeed OBJECT-TYPE The speed of the port which is transmitted as part of a Call Setup frame. A Voice call will be established if there is enough bandwidth at each end to provide the minimum configured rate. | 1.3.6.1.4.1.173.7.3.8.2.1.4 | INTEGER {bps-4800(1), bps-8000(2), bps-32000(3), bps-64000(4)} | read-only | mandatory |
| portVoiceOperDTMF OBJECT-TYPE The flag to enable, disable, or specify a time span over which DTMF (Dual Tone Multi Frequency) tones will be regenerated. 0 = pass tones transparently to the remote device. 1 = detect incoming tones and regenerate as received. 2-255 = regenerate tones for the specified seconds. | 1.3.6.1.4.1.173.7.3.8.2.1.5 | INTEGER (0..255) | read-only | mandatory |
| portVoiceOperInterface OBJECT-TYPE The type of interface (in conjunction with the Telephony Interface Type) that will be used by the Voice channel. This requires rebooting for the change to take effect. Telephony Type Interface Type -------------- -------------- OPX (FXO) Loop Start SLT (FXS) Loop Start E&M 4W E&M, 4W E&M TE, 2W E&M, 2W E&M TE AC15 AC15A, AC15C | 1.3.6.1.4.1.173.7.3.8.2.1.6 | INTEGER {em-4w(1), em-2w(2), loop-start(3), ac15-a(4), ac15-b(6), em-4w-te(10), em-2w-te(11)} | read-only | mandatory |
| portVoiceOperTETimer OBJECT-TYPE The delay at which the E&M 'E' lead follows the 'M' lead. | 1.3.6.1.4.1.173.7.3.8.2.1.7 | INTEGER (0..255) | read-only | mandatory |
| portVoiceOperLevelIn OBJECT-TYPE The local voice level into the voice port. This adjusts the sensitivity of the local voice channel to the signal from the attached device. The purpose of this is to match the voice channel dB level to the input signal. A more negative setting produces a higher input gain. If the level is reduced, the voice channel will be more sensitive to the input. This will also cause the voice output at the remote device to sound louder. | 1.3.6.1.4.1.173.7.3.8.2.1.8 | INTEGER (-22..7) | read-only | mandatory |
| portVoiceOperLevelOut OBJECT-TYPE The local voice level out of the voice port. A more positive setting produces a higher volume. | 1.3.6.1.4.1.173.7.3.8.2.1.9 | INTEGER (-22..7) | read-only | mandatory |
| portVoiceOperCallTimer OBJECT-TYPE The amount of time the node will wait for a response to a Call Connect or Call Clear request. When the node issues a request, it will set a timer to the value configured here. If that timer expires with no response from the destination, the node will generate a busy tone. | 1.3.6.1.4.1.173.7.3.8.2.1.10 | INTEGER (1..30) | read-only | mandatory |
| portVoiceOperHuntGroup OBJECT-TYPE The hunt group that includes the voice channel. | 1.3.6.1.4.1.173.7.3.8.2.1.11 | INTEGER {none(1), a(2), b(3)} | read-only | mandatory |
| portVoiceOperLongDialPrefix OBJECT-TYPE The character that will be required preceeding calls using the long call format. When the user at an attached device dials a long form number, it must be preceeded by the prefix character specified here. | 1.3.6.1.4.1.173.7.3.8.2.1.12 | OCTET STRING (SIZE(1)) | read-only | mandatory |
| portVoiceOperSLTTimeout OBJECT-TYPE The time the local port will wait before an actual fax transmission begins. If there is no fax tone when this timer expires, the connection will be terminated. | 1.3.6.1.4.1.173.7.3.8.2.1.13 | INTEGER (1..99) | read-only | mandatory |
| portVoiceOperLinkDownBusy OBJECT-TYPE This flag enables or disables automatic busy-out of channels when the link is down. When enabled, the system will automatically busy-out channels when the composite link is down. When disabled, channels remain on-hook when the link is down. If your application is connected to a PBX that can route calls to another alternate source based on an all busy condition, enable this so the PBX will recognize this condition and reroute the calls while the composite link is down. | 1.3.6.1.4.1.173.7.3.8.2.1.14 | INTEGER {disabled(1), enabled(2)} | read-only | mandatory |
| portVoiceOperFaxSupported OBJECT-TYPE The flag to indicate whether or not faxes will be transmitted on the port. If no, all calls will be treated as voice. If yes, both voice and fax will be transmitted. | 1.3.6.1.4.1.173.7.3.8.2.1.15 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| portVoiceOperTelephonyType OBJECT-TYPE The type of interface (in conjunction with the Interface Type) that will be used by the Voice channel. This requires rebooting for the change to take effect. Telephony Type Interface Type -------------- -------------- OPX (FXO) Loop Start SLT (FXS) Loop Start E&M 4W E&M, 4W E&M TE, 2W E&M, 2W E&M TE AC15 AC15A, AC15C | 1.3.6.1.4.1.173.7.3.8.2.1.16 | INTEGER {opx(1), slt(2), em(3), ac15(4)} | read-only | mandatory |
| portVoiceOperJitter OBJECT-TYPE The amount of jitter delay. | 1.3.6.1.4.1.173.7.3.8.2.1.17 | INTEGER (10..255) | read-only | mandatory |
| portVoiceOperSampleDelay OBJECT-TYPE The amount of sample delay. | 1.3.6.1.4.1.173.7.3.8.2.1.18 | INTEGER (0..255) | read-only | mandatory |
| portVoiceOperDialTimer OBJECT-TYPE The delay the node will use to determine when variable length dialing is complete. (Variable length dialing allows the user to place a call without entering the configured number of digits for the speed dial number.) | 1.3.6.1.4.1.173.7.3.8.2.1.19 | INTEGER (0..10) | read-only | mandatory |
| portVoiceOperAutoDial OBJECT-TYPE The flag to enable or disable the auto dial feature. Note that enabling this feature will disable the variable length dialing feature for this channel. | 1.3.6.1.4.1.173.7.3.8.2.1.20 | INTEGER {disabled(1), enabled(2)} | read-only | mandatory |
| portVoiceOperSuppression OBJECT-TYPE The silence suppression level. A larger silence suppression level allows more data channels to operate simultaneously with the voice channels. | 1.3.6.1.4.1.173.7.3.8.2.1.21 | INTEGER {very-low(1), low(2), medium(3), high(4), very-high(5)} | read-only | mandatory |
| portVoiceOperAutoDialNumber OBJECT-TYPE The number to which the node will attempt to connect when the handset attached to this port is taken off-hook. This is applicable only when the Auto Dial feature is enabled. | 1.3.6.1.4.1.173.7.3.8.2.1.22 | OCTET STRING (SIZE(0..4)) | read-only | mandatory |
| portVoiceOperAutoPoll OBJECT-TYPE The flag to enable or disable auto polling. This is applicable only when the Auto Dial feature is enabled. When enabled, the node periodically polls the destination. If the poll is not acknowledged, the node will busy-out the channel. This can be useful in situations where the destination is an emergency number that must always be available. If the destination does not answer the automatic poll, the busy-out condition will notify an attached PBX that the emergency call should be routed to another call routing device. | 1.3.6.1.4.1.173.7.3.8.2.1.23 | INTEGER {disabled(1), enabled(2)} | read-only | mandatory |
| portVoiceOperAutoPollTimer OBJECT-TYPE The frequency with which an Auto Poll will be sent. This is applicable only when auto poll is enabled. | 1.3.6.1.4.1.173.7.3.8.2.1.24 | INTEGER (5..30) | read-only | mandatory |
| portVoiceOperExtDigitsSource OBJECT-TYPE The source of the extended digits when the user of attached equipment dials a speed dial number. This is applicable only when the number of extended dial digits is greater than zero. When map is specified, extended digits are taken from the extended digits field in the map table. When user is specified, extended digits are taken from the user of attached equipment. | 1.3.6.1.4.1.173.7.3.8.2.1.25 | INTEGER {map(1), user(2)} | read-only | mandatory |
| portVoiceOperNumDigitsDelete OBJECT-TYPE The number of leading dial digits that will be deleted before a dial string is forwarded. This is primarily used to delete leading dial digits that may be inserted by an attached PBX. | 1.3.6.1.4.1.173.7.3.8.2.1.26 | INTEGER (0..4) | read-only | mandatory |
| portVoiceOperForwardDelay OBJECT-TYPE The length of a pause that can be inserted in an extended dial string that is being forwarded. This is applicable only when forwarded output digits is all or extended. When a comma is encountered in an extended digits string, the node will pause for the length of time specified here before additional extended digits are forwarded. | 1.3.6.1.4.1.173.7.3.8.2.1.27 | INTEGER (0..40) | read-only | mandatory |
| portVoiceOperForwardedType OBJECT-TYPE The method how the dial digits will be forwarded. This is applicable only when forwarded output digits is all or extended. | 1.3.6.1.4.1.173.7.3.8.2.1.28 | INTEGER {dtmf(1), pulse(2)} | read-only | mandatory |
| portVoiceOperForwardedDigits OBJECT-TYPE The flag indicating which dial digits, if any, to forward. If none, dial digits are not forwarded to the destination device when a call is initiated on this channel. If all, the dialed speed dial number and associated extended digits are forwarded to the destination device. If extended, only the extended digit string is forwarded. | 1.3.6.1.4.1.173.7.3.8.2.1.29 | INTEGER {none(1), all(2), extended(3)} | read-only | mandatory |
| portVoiceOperMakeRatio OBJECT-TYPE The make ratio of each digit pulse that is forwarded. This is applicable only when forwarded output digits is all or extended and forwarded digit type is pulse. | 1.3.6.1.4.1.173.7.3.8.2.1.30 | INTEGER (20..80) | read-only | mandatory |
| portVoiceOperBreakRatio OBJECT-TYPE The break ratio of each digit pulse that is forwarded. This is applicable only when forwarded output digits is all or extended and forwarded digit type is pulse. | 1.3.6.1.4.1.173.7.3.8.2.1.31 | INTEGER (20..80) | read-only | mandatory |
| portVoiceOperDTMFOnDuration OBJECT-TYPE The length of a tone that will be used to produce a single DTMF digit. This is applicable only when forwarded output digits is all or extended and forwarded digit type is DTMF. | 1.3.6.1.4.1.173.7.3.8.2.1.32 | INTEGER (30..1000) | read-only | mandatory |
| portVoiceOperDTMFOffDuration OBJECT-TYPE The length of silence between DTMF tones in a dial digit string. This is applicable only when forwarded output digits is all or extended and forwarded digit type is DTMF. | 1.3.6.1.4.1.173.7.3.8.2.1.33 | INTEGER (30..1000) | read-only | mandatory |
| portVoiceOperToneType OBJECT-TYPE The tone type to detect/regenerate for forwarding DTMF/MF. | 1.3.6.1.4.1.173.7.3.8.2.1.34 | INTEGER {dtmf(1), mf(2)} | read-only | mandatory |
| nlInterfaces OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.4 | |||
| nlIfTable OBJECT-TYPE A Table to describe each interface on a node. This table is indexed by RLP and Port number and can be used to identify the corresponding MIB-II ifIndex of a Port as well as additional port information maintained by Netlink. | 1.3.6.1.4.1.173.7.4.1 | not-accessible | mandatory | |
| nlIfEntry OBJECT-TYPE An Interface entry containing objects relating to interfaces. | 1.3.6.1.4.1.173.7.4.1.1 | not-accessible | mandatory | |
| nlIfRlp OBJECT-TYPE The RLP number on the node. RLP numbers 1-8 are Physical RLP cards, and RLP number 250, 251 and 252 define IP, IPX and LLC2 interfaces respectively. | 1.3.6.1.4.1.173.7.4.1.1.1 | INTEGER | read-only | mandatory |
| nlIfPort OBJECT-TYPE The Port number on the RLP. Port numbers 1-8 are known to be physical ports, and 9-64 are logical ports. If the RLP number identifies an IP, IPX or LLC2 interface, then the port number can be 1-257 (IP), 1-64 (IPX), or 1-96 (LLC2). | 1.3.6.1.4.1.173.7.4.1.1.2 | INTEGER | read-only | mandatory |
| nlIfType OBJECT-TYPE The type of interface | 1.3.6.1.4.1.173.7.4.1.1.3 | INTEGER {other(1), regular1822(2), hdh1822(3), ddnX25(4), rfc877x25(5), ethernetCsmacd(6), iso88023Csmacd(7), iso88024TokenBus(8), iso88025TokenRing(9), iso88026Man(10), starLan(11), proteon10Mbit(12), proteon80Mbit(13), hyperchannel(14), fddi(15), lapb(16), sdlc(17), ds1(18), e1(19), basicISDN(20), primaryISDN(21), propPointToPointSerial(22), ppp(23), softwareLoopback(24), eon(25), ethernet3Mbit(26), nsip(27), slip(28), ultra(29), ds3(30), sip(31), frameRelay(32), rs232(33), para(34), arcnet(35), arcnetPlus(36), atm(37), miox25(38), sonet(39), x25ple(40), iso88022llc(41), localTalk(42), smdsDxi(43), frameRelayService(44), v35(45), hssi(46), hippi(47), modem(48), aal5(49), sonetPath(50), sonetVT(51), smdsIcip(52), propVirtual(53), propMultiplexor(54), trunk(200), async(201), bsci(202), logicalPort(203), t1(204), ip(205), ipx(206), llc2(207), voice(208)} | read-only | mandatory |
| nlIfIndex OBJECT-TYPE The associated index into the MIB-II ifTable for this port | 1.3.6.1.4.1.173.7.4.1.1.4 | INTEGER | read-only | mandatory |
| nlIfTableIndex OBJECT-TYPE The associated index into an enterprise table used to describe additional information for this port. See nlIfTableOid as the pointer to the actual table. | 1.3.6.1.4.1.173.7.4.1.1.5 | INTEGER | read-only | mandatory |
| nlIfTableOid OBJECT-TYPE The OID of the table Entry that contains additional information about this port. The OID will point to a specific table depending on the type of port. | 1.3.6.1.4.1.173.7.4.1.1.6 | OBJECT IDENTIFIER | read-only | mandatory |
| nlIfConnectorType OBJECT-TYPE The physical connector type used for this port. Valid for ports 1-8 only. | 1.3.6.1.4.1.173.7.4.1.1.7 | INTEGER {none(2), rs232(3), v25bis-dial(4), v35(5), rs449(6), rs530(7), x21(8), csudsu(9), t1(10), e1(11), voice(13)} | read-only | mandatory |
| nlIfPortStatus OBJECT-TYPE The status of this port state. Valid for ports 1-64 only. | 1.3.6.1.4.1.173.7.4.1.1.8 | INTEGER {linkUp(1), restarting(2), operational(3), disabled(4), disconnect(5), configured(6), dialReady(7), quiesced(8), failed(9), hardwareFault(10), other(11), ipl(12), na(13), remoteLoopback(14), blueAlarm(15), yellowAlarm(16), redAlarm(17), onHook(18), offHook(19), dialing(20), activeVoiceCall(21), onHookPending(22)} | read-only | mandatory |
| nlIfPhyPort OBJECT-TYPE The Underlying Physical Port number on the RLP of this logical port. Port numbers 1-8 are valid, but this field is only applicable if the nlIfPort field is 9-64. | 1.3.6.1.4.1.173.7.4.1.1.9 | INTEGER | read-only | mandatory |
| nlIfLlc2Interfaces OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.4.2 | |||
| nlIfLlc2LANTable OBJECT-TYPE A Table to define LLC2 interfaces over LAN. | 1.3.6.1.4.1.173.7.4.2.1 | not-accessible | mandatory | |
| nlIfLlc2LANEntry OBJECT-TYPE An LLC2 LAN Interface entry containing objects relating to LLC2 LAN interfaces. | 1.3.6.1.4.1.173.7.4.2.1.1 | not-accessible | mandatory | |
| nlIfLlc2LANRlp OBJECT-TYPE The RLP number on the node. For LLC2 LAN interfaces, this must be 252. | 1.3.6.1.4.1.173.7.4.2.1.1.1 | INTEGER | read-only | mandatory |
| nlIfLlc2LANPort OBJECT-TYPE The Port number on the RLP. For LLC2 LAN interfaces, this corresponds to the LAN card number. | 1.3.6.1.4.1.173.7.4.2.1.1.2 | INTEGER | read-only | mandatory |
| nlIfLlc2LANType OBJECT-TYPE The type of the LLC2 interface- either ethernet or token ring. | 1.3.6.1.4.1.173.7.4.2.1.1.3 | INTEGER {ethernet(1), token-ring(2)} | read-write | mandatory |
| nlIfLlc2LANCard OBJECT-TYPE The LAN card that the LLC2 interface is running on. | 1.3.6.1.4.1.173.7.4.2.1.1.4 | INTEGER (1..2) | read-only | mandatory |
| nlIfLlc2LANID OBJECT-TYPE Valid only if the type of the LLC2 LAN interface is token ring. Identifies the token ring adapter to the network. | 1.3.6.1.4.1.173.7.4.2.1.1.5 | INTEGER (0..4095) | read-write | mandatory |
| nlIfLlc2LANInterface OBJECT-TYPE The LLC2 interface number. | 1.3.6.1.4.1.173.7.4.2.1.1.6 | INTEGER (1..2) | read-only | mandatory |
| nlIfLlc2LANRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the nlIfLlc2LANTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.4.2.1.1.7 | RowStatus | read-write | mandatory |
| nlIfLlc2LANPriority OBJECT-TYPE Interface priority- allows setting a priority for traffic within the node. The higher the number, the higher the priority relative to other intra-nodal traffic. | 1.3.6.1.4.1.173.7.4.2.1.1.8 | INTEGER (0..9) | read-write | mandatory |
| nlIfLlc2LANBlockedPortFlag OBJECT-TYPE The blocked port flag. | 1.3.6.1.4.1.173.7.4.2.1.1.9 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| nlIfLlc2FrTable OBJECT-TYPE A Table to define LLC2 interfaces over Frame Relay. | 1.3.6.1.4.1.173.7.4.2.2 | not-accessible | mandatory | |
| nlIfLlc2FrEntry OBJECT-TYPE An LLC2 FR Interface entry containing objects relating to LLC2 FR interfaces. | 1.3.6.1.4.1.173.7.4.2.2.1 | not-accessible | mandatory | |
| nlIfLlc2FrRlp OBJECT-TYPE The RLP number on the node. | 1.3.6.1.4.1.173.7.4.2.2.1.1 | INTEGER (1..8) | read-only | mandatory |
| nlIfLlc2FrPort OBJECT-TYPE The Port number on the RLP. Port numbers 1-8 are known to be physical ports, and channels are 193-241. | 1.3.6.1.4.1.173.7.4.2.2.1.2 | INTEGER (1..255) | read-only | mandatory |
| nlIfLlc2FrDLCI OBJECT-TYPE The DLCI number used to identify the entry in the table. The range is 16-991. | 1.3.6.1.4.1.173.7.4.2.2.1.3 | INTEGER (16..991) | read-only | mandatory |
| nlIfLlc2FrFormat OBJECT-TYPE The RFC1490 encapsulation method used for LLC2 traffic. | 1.3.6.1.4.1.173.7.4.2.2.1.4 | INTEGER {native-llc2(1), tb-8023(2), srb-8025(3)} | read-only | mandatory |
| nlIfLlc2FrPriority OBJECT-TYPE Interface priority- allows setting a priority for traffic within the node. The higher the number, the higher the priority relative to other intra-nodal traffic. | 1.3.6.1.4.1.173.7.4.2.2.1.5 | INTEGER (0..9) | read-write | mandatory |
| nlIfLlc2FrBAG OBJECT-TYPE Assigns the interface to one of sixteen groups whose parameters regulate bandwidth usage. | 1.3.6.1.4.1.173.7.4.2.2.1.6 | INTEGER (1..16) | read-write | mandatory |
| nlIfLlc2FrHostMACAddress OBJECT-TYPE The MAC address of the host or workstation to which the remote device needs to connect. Valid only if the format is native-llc2. | 1.3.6.1.4.1.173.7.4.2.2.1.7 | MacAddress | read-write | mandatory |
| nlIfLlc2FrSessionType OBJECT-TYPE If originated, means that LLC2 connects from the configured Host MAC address can use this interface. If terminated, connections to the configured address can use this interface. Valid only if the format is native-llc2. | 1.3.6.1.4.1.173.7.4.2.2.1.8 | INTEGER {terminated(1), originated(2), not-applicable(3)} | read-write | mandatory |
| nlIfLlc2FrLANID OBJECT-TYPE Identifies the ring number used by a frame relay-compliant source-route bridge at the other end of this PVC. Valid only if the format is srb-8025. | 1.3.6.1.4.1.173.7.4.2.2.1.9 | INTEGER (0..4095) | read-write | mandatory |
| nlIfLlc2FrInterface OBJECT-TYPE LLC2 interface number. | 1.3.6.1.4.1.173.7.4.2.2.1.10 | INTEGER | read-only | mandatory |
| nlIfLlc2FrRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the nlIfLlc2FrTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.4.2.2.1.11 | RowStatus | read-write | mandatory |
| nlIfLlc2FrBlockedPortFlag OBJECT-TYPE The blocked port flag. | 1.3.6.1.4.1.173.7.4.2.2.1.12 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| ipxConfig OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.4.3 | |||
| ipxConfigRouting OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.4.3.1 | |||
| ipxStaticRouteConfigTable OBJECT-TYPE The IPX Static Route Configuration Table | 1.3.6.1.4.1.173.7.4.3.1.1 | not-accessible | mandatory | |
| ipxStaticRouteConfigEntry OBJECT-TYPE Each entry corresponds to one instance of IPX Static Routing on the system | 1.3.6.1.4.1.173.7.4.3.1.1.1 | not-accessible | mandatory | |
| ipxStaticRouteConfigCircIndex OBJECT-TYPE The unique identifier of the circuit used to reach the first hop in the static route | 1.3.6.1.4.1.173.7.4.3.1.1.1.1 | INTEGER (1..65535) | read-only | mandatory |
| ipxStaticRouteConfigNetNum OBJECT-TYPE The IPX network number of the route's destination | 1.3.6.1.4.1.173.7.4.3.1.1.1.2 | OCTET STRING (SIZE(4)) | read-only | mandatory |
| ipxStaticRouteConfigRouter OBJECT-TYPE The hex value of the node address of the router that will forward a packet when this route is used. If Novell's IPXWAN is used on the interface, this field will be ignored | 1.3.6.1.4.1.173.7.4.3.1.1.1.3 | OCTET STRING (SIZE(6)) | read-write | mandatory |
| ipxStaticRouteConfigRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the ipxStaticRouteTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.4.3.1.1.1.4 | RowStatus | read-write | mandatory |
| ipxServConfigTable OBJECT-TYPE The IPX Static Route Configuration Table | 1.3.6.1.4.1.173.7.4.3.1.2 | not-accessible | mandatory | |
| ipxServConfigEntry OBJECT-TYPE Each entry corresponds to one instance of IPX Static Routing on the system | 1.3.6.1.4.1.173.7.4.3.1.2.1 | not-accessible | mandatory | |
| ipxServConfigServiceType OBJECT-TYPE The Service Type, a SAP service code | 1.3.6.1.4.1.173.7.4.3.1.2.1.1 | INTEGER (1..65535) | read-only | mandatory |
| ipxServConfigServName OBJECT-TYPE The Sercice Name, identifies a specific server in the IPX network. | 1.3.6.1.4.1.173.7.4.3.1.2.1.2 | OCTET STRING (SIZE(1..48)) | read-only | mandatory |
| ipxServConfigServNetworkAddress OBJECT-TYPE The IPX network number portion of the IPX address of the server identified by ServName | 1.3.6.1.4.1.173.7.4.3.1.2.1.3 | INTEGER | read-write | mandatory |
| ipxServConfigServNodeAddress OBJECT-TYPE The node portion of the IPX address of the service | 1.3.6.1.4.1.173.7.4.3.1.2.1.4 | OCTET STRING (SIZE(6)) | read-write | mandatory |
| ipxServConfigServSocketNumber OBJECT-TYPE The socket portion of the IPX address of the service | 1.3.6.1.4.1.173.7.4.3.1.2.1.5 | INTEGER (0..65535) | read-write | mandatory |
| ipxServConfigInterveningNetworks OBJECT-TYPE The number of routers that a packet must pass through t reach the server | 1.3.6.1.4.1.173.7.4.3.1.2.1.6 | INTEGER (1..65535) | read-write | mandatory |
| ipxServConfigGatewayAddress OBJECT-TYPE The node address of the router thar will forward a packet | 1.3.6.1.4.1.173.7.4.3.1.2.1.7 | OCTET STRING (SIZE(6)) | read-write | mandatory |
| ipxServConfigInterface OBJECT-TYPE The IPX network number assigned to the interface used to send packets that are destined for this server | 1.3.6.1.4.1.173.7.4.3.1.2.1.8 | INTEGER (0..65535) | read-write | mandatory |
| ipxServConfigRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the ipxServTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.4.3.1.2.1.9 | RowStatus | read-write | mandatory |
| ipxConfigInterface OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.4.3.2 | |||
| ipxInterfaceTable OBJECT-TYPE The IPX Interface Table | 1.3.6.1.4.1.173.7.4.3.2.6 | not-accessible | mandatory | |
| ipxInterfaceEntry OBJECT-TYPE | 1.3.6.1.4.1.173.7.4.3.2.6.1 | not-accessible | mandatory | |
| ipxInterfaceNumber OBJECT-TYPE The Interface Number, a sequential number to identify the interface | 1.3.6.1.4.1.173.7.4.3.2.6.1.1 | INTEGER (1..64) | read-only | mandatory |
| ipxInterfaceBlockedPortFlag OBJECT-TYPE This flag causes the IPX interface to be enabled (N) or disabled (Y) at node IPL. The port will remain in that state until this parameter is changed | 1.3.6.1.4.1.173.7.4.3.2.6.1.2 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| ipxInterfaceType OBJECT-TYPE The interface type. 802.5 is not valid on FRX4000 | 1.3.6.1.4.1.173.7.4.3.2.6.1.3 | INTEGER {ethernet(1), eight025(2), x25(3), frl(4)} | read-write | mandatory |
| ipxInterfaceFrameType OBJECT-TYPE The frame type - depends on the interfece type. Valid combinations are: Ethernet, 802.5 - typeII, raw, llc, snap Frame relay, X25 - typeII | 1.3.6.1.4.1.173.7.4.3.2.6.1.4 | INTEGER {typeII(1), raw(2), llc(3), snap(4)} | read-write | mandatory |
| ipxInterfaceMaxTransUnit OBJECT-TYPE Maximum frame size that can be transmitted or received over the IPX interface.: Valid ranges are: Ethernet - (45-1518) 802.5 - (48-4096) Frame relay, X25 - (31-4096) | 1.3.6.1.4.1.173.7.4.3.2.6.1.5 | INTEGER | read-write | mandatory |
| ipxInterfaceNetworkAddress OBJECT-TYPE Identifies the local interface to the Novell Network | 1.3.6.1.4.1.173.7.4.3.2.6.1.6 | INTEGER | read-write | mandatory |
| ipxInterfaceBandwidthAllocGroup OBJECT-TYPE Assigns the IPX interface to one of sixteen groups whose parameters regulate bandwidth usage | 1.3.6.1.4.1.173.7.4.3.2.6.1.7 | INTEGER (1..16) | read-write | mandatory |
| ipxInterfacePortDiagEnabled OBJECT-TYPE Enables/Disables the IPX interface's ability to handle Novell diagonistics packets | 1.3.6.1.4.1.173.7.4.3.2.6.1.8 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| ipxInterfaceNetBIOSEnabled OBJECT-TYPE Determines whether Novell-encapsulated NetBIOS frames received on the interface will be processed | 1.3.6.1.4.1.173.7.4.3.2.6.1.9 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| ipxInterfaceNetBIOSHops OBJECT-TYPE Maximum number of hops allowed for routing a Novell-encapsulated NetBIOS frame | 1.3.6.1.4.1.173.7.4.3.2.6.1.10 | INTEGER (0..255) | read-write | mandatory |
| ipxInterfacePeriodicRIPEnabled OBJECT-TYPE Determines whether the node will originate periodic IPX Routing Information Protocol messages from this interface to inform the network that the route through this interface is viable | 1.3.6.1.4.1.173.7.4.3.2.6.1.11 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| ipxInterfacePeriodicRIPTimer OBJECT-TYPE This is the interval between the periodic IPX RIP broadcasts from this interface | 1.3.6.1.4.1.173.7.4.3.2.6.1.12 | INTEGER (1..65535) | read-write | mandatory |
| ipxInterfacePeriodicSAPEnabled OBJECT-TYPE Determines whether the node will originate periodic IPX SAP messages from this interface to inform the network which SAP entries in the routing table are viable | 1.3.6.1.4.1.173.7.4.3.2.6.1.13 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| ipxInterfacePeriodicSAPTimer OBJECT-TYPE The interval between the periodic SAP broadcasts from this interface | 1.3.6.1.4.1.173.7.4.3.2.6.1.14 | INTEGER (1..65535) | read-write | mandatory |
| ipxInterfaceRIPEnabled OBJECT-TYPE Datermines whether this interface will support RIP proceswsing | 1.3.6.1.4.1.173.7.4.3.2.6.1.15 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| ipxInterfaceRIPAgeTimer OBJECT-TYPE This is used to delete route entries in the routing information table. The timer starts/restarts each time an entry is created/updated. If the timer expires, the router will assume that the entry is no longer valid and the entry will be deleteda from the table | 1.3.6.1.4.1.173.7.4.3.2.6.1.16 | INTEGER (0..65535) | read-write | mandatory |
| ipxInterfaceRIPMaxSize OBJECT-TYPE Maximum possible RIP packet size | 1.3.6.1.4.1.173.7.4.3.2.6.1.17 | INTEGER (54..446) | read-write | mandatory |
| ipxInterfaceSAPEnabled OBJECT-TYPE Determines whether the interface will support SAP or not | 1.3.6.1.4.1.173.7.4.3.2.6.1.18 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| ipxInterfaceSAPAgeTimer OBJECT-TYPE This is used to delete route entries from the router information table. The timer starts/restars each time an entry is created/updated. If the timer expires, the router will assume that the entry is no longer valid and the entry will be deleted from the table | 1.3.6.1.4.1.173.7.4.3.2.6.1.19 | INTEGER (0..65535) | read-write | mandatory |
| ipxInterfaceTransportTime OBJECT-TYPE is the time (in 55 milliseconds unit) that will normally take to forward frames out of interface. Recommmended values are 1 for LAN interfaces and 30 for WAN interfaces. A value of 0 indicates that the back to back frame forwarding is acceptable. This time is used to calculate the least cost path during routing. If IPXWAMN is (Y), Transport time will be overridden by the value calculated by IPXWAN | 1.3.6.1.4.1.173.7.4.3.2.6.1.20 | INTEGER (1..255) | read-write | mandatory |
| ipxInterfaceSerializationEnabled OBJECT-TYPE Determines whether NetWare file server serialization security frames will be forwarded on the interface. These broadcasts frames are used by Novell to hold informations regarding the licensing of the file server executables | 1.3.6.1.4.1.173.7.4.3.2.6.1.21 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| ipxInterfaceWatchdogSpoofingEnabled OBJECT-TYPE Determines whether this interface will be used by the local node to respond to (keep alive) messages on behalf of the client workstations. Novell servers periodically issue these messages to all clients to determine whether each client is still alive | 1.3.6.1.4.1.173.7.4.3.2.6.1.22 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| ipxInterfaceLanCardNumber OBJECT-TYPE The card number installed in an FRX6000. The first or only LAN card installed is always 0, and the second is card 1 | 1.3.6.1.4.1.173.7.4.3.2.6.1.23 | INTEGER (0..1) | read-write | mandatory |
| ipxInterfaceWanEnabled OBJECT-TYPE Determines whether Novell's IPXWAN protocol will be used on the interface. IPXWAN specifies a method for IPX routers to communicate across WAN links. FRX6000 and FRX4000 implement IPXWAN running over RFC 1490-complaint frame relay and RFC1356-complaint X.25 | 1.3.6.1.4.1.173.7.4.3.2.6.1.24 | INTEGER {no(1), yes(2), not-applicable(3)} | read-write | mandatory |
| ipxInterfaceSourceSubscriber OBJECT-TYPE Subscruber id that defines an IPX interface in the node, by associating itself with port 66 (a number reserved for the IPXinterface) on the RLP that has an IPX installed on it. .. Valid only for type X.25 | 1.3.6.1.4.1.173.7.4.3.2.6.1.25 | OCTET STRING (SIZE(0..15)) | read-write | mandatory |
| ipxInterfaceDestinationSubscriber OBJECT-TYPE Subscriber ID associated with the physical X.25 port that will be used for the IPX interface . .. Valid only for type X.25 | 1.3.6.1.4.1.173.7.4.3.2.6.1.26 | OCTET STRING (SIZE(0..15)) | read-write | mandatory |
| ipxInterfaceSVCRetryTimer OBJECT-TYPE The frequency with which calls will be placed to try to establish a connection .. Valid only for type X.25 | 1.3.6.1.4.1.173.7.4.3.2.6.1.27 | INTEGER (5..60) | read-write | mandatory |
| ipxInterfaceSVCIdleTimer OBJECT-TYPE is a period that an IPX connection can remain active with no traffic before the connection is cleared. .. Valid only for type X.25 | 1.3.6.1.4.1.173.7.4.3.2.6.1.28 | INTEGER (0..5) | read-write | mandatory |
| ipxInterfaceMaxVC OBJECT-TYPE This specifies a number of virtual circuits over which IPX traffic will be transmitted in parallel. .. Valid only for type X.25 | 1.3.6.1.4.1.173.7.4.3.2.6.1.29 | INTEGER (1..8) | read-write | mandatory |
| ipxInterfacePVCConnection OBJECT-TYPE Identifies this interface as one of a PVC. .. Valid only for type X.25 | 1.3.6.1.4.1.173.7.4.3.2.6.1.30 | INTEGER {no(1), yes(2), not-applicable(3)} | read-write | mandatory |
| ipxInterfaceSourceCard OBJECT-TYPE Identifies the location of this end of the frame relay IPX interface. .. Valid only for frame relay | 1.3.6.1.4.1.173.7.4.3.2.6.1.31 | INTEGER (0..7) | read-write | mandatory |
| ipxInterfaceSourcePort OBJECT-TYPE Identifies the location of this end of the frame relay IPX interface. .. Valid only for frame relay | 1.3.6.1.4.1.173.7.4.3.2.6.1.32 | INTEGER (0..7) | read-write | mandatory |
| ipxInterfaceSourceDLCI OBJECT-TYPE Identifies the location of this end of the frame relay IPX interface. .. Valid only for frame relay | 1.3.6.1.4.1.173.7.4.3.2.6.1.33 | INTEGER (16..991) | read-write | mandatory |
| ipxInterfaceRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the ipxInterfaceTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.4.3.2.6.1.34 | RowStatus | read-write | mandatory |
| ipxConfigNodeDefault OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.4.3.3 | |||
| ipxNodeDefaultConfigNetworkAddress OBJECT-TYPE Identifies the node to the IPX network | 1.3.6.1.4.1.173.7.4.3.3.1 | INTEGER | read-write | mandatory |
| ipxNodeDefaultConfigRIPSAPGap OBJECT-TYPE The minimum delay between consecutive RIP and SAP transmissions | 1.3.6.1.4.1.173.7.4.3.3.2 | INTEGER (0..100) | read-write | mandatory |
| ipxNodeDefaultConfigRouterName OBJECT-TYPE An unique identifier within the IPX network | 1.3.6.1.4.1.173.7.4.3.3.3 | OCTET STRING (SIZE(1..48)) | read-write | mandatory |
| nlIfIpInterfaces OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.4.4 | |||
| nlIfIpTable OBJECT-TYPE A Table to define IP interfaces over frame relay, X.25, or LAN (ethernet, 802.3, 802.5). | 1.3.6.1.4.1.173.7.4.4.1 | not-accessible | mandatory | |
| nlIfIpEntry OBJECT-TYPE An IP Interface entry containing objects relating to IP interfaces. | 1.3.6.1.4.1.173.7.4.4.1.1 | not-accessible | mandatory | |
| nlIfIpInterface OBJECT-TYPE The interface number which uniquely identifies the interface to which this entry is applicable. The interface identified by a particular value of this number is NOT the same interface as defined by the same value of ifIndex. | 1.3.6.1.4.1.173.7.4.4.1.1.1 | INTEGER (1..257) | read-only | mandatory |
| nlIfIpMtu OBJECT-TYPE The maximum size (in bytes) of the data field that can be used to encapsulate an IP datagram for transmission over the interface. If the interface type is LAN based, then the maximum size value cannot exceed 1500. | 1.3.6.1.4.1.173.7.4.4.1.1.2 | INTEGER (1..4096) | read-write | mandatory |
| nlIfIpNetworkMask OBJECT-TYPE The mask used during routing to determine the portion of the address associated with the network. | 1.3.6.1.4.1.173.7.4.4.1.1.3 | IpAddress | read-write | mandatory |
| nlIfIpRouteMetric OBJECT-TYPE The number of network hops (network gateways in the overall path over the internet) associated with this interface. | 1.3.6.1.4.1.173.7.4.4.1.1.4 | INTEGER (0..255) | read-write | mandatory |
| nlIfIpICMPAddRoutes OBJECT-TYPE The flag which indicates whether IP may add routes obtained by ICMP, whose error and control function is used to send re-direction options back to the source if problems are discovered. | 1.3.6.1.4.1.173.7.4.4.1.1.5 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| nlIfIpRIPDeltaUpdates OBJECT-TYPE The frequency with which RIP messages will be sent to every neighbor node, containing any changes to the routing table that occurred since the last full update. | 1.3.6.1.4.1.173.7.4.4.1.1.6 | INTEGER (10..300) | read-write | mandatory |
| nlIfIpRIPFullUpdates OBJECT-TYPE The frequency with which updates of the entire routing table will be sent to every neighbor node, via one or more RIP messages. | 1.3.6.1.4.1.173.7.4.4.1.1.7 | INTEGER (10..300) | read-write | mandatory |
| nlIfIpPriority OBJECT-TYPE The priority setting for traffic within the node. The higher the number, the higher the priority relative to other intra-nodal traffic. | 1.3.6.1.4.1.173.7.4.4.1.1.8 | INTEGER (0..9) | read-write | mandatory |
| nlIfIpBAG OBJECT-TYPE The bandwidth allocation group to which this interface is assigned to. This object is only valid when the interface type is frame relay or proprietary virtual. | 1.3.6.1.4.1.173.7.4.4.1.1.9 | INTEGER (1..16) | read-write | mandatory |
| nlIfIpType OBJECT-TYPE The type of IP interface. | 1.3.6.1.4.1.173.7.4.4.1.1.10 | INTEGER {other(1), rfc877x25(5), ethernetCsmacd(6), iso88023Csmacd(7), iso88025TokenRing(9), frameRelay(32), propVirtual(53)} | read-write | mandatory |
| nlIfIpSourceAddress OBJECT-TYPE The IP address of the end-to-end sender. | 1.3.6.1.4.1.173.7.4.4.1.1.11 | IpAddress | read-write | mandatory |
| nlIfIpDestAddress OBJECT-TYPE The IP address of the end-to-end receiver. This object is only valid when the interface type is X.25 or proprietary virtual, or when the interface type is frame relay and the inverse ARP flag indicates disabled. | 1.3.6.1.4.1.173.7.4.4.1.1.12 | IpAddress | read-write | mandatory |
| nlIfIpBroadcastAddress OBJECT-TYPE The IP address that is used to send to all LAN hosts on the network. This object is only valid when the interface type is LAN based. | 1.3.6.1.4.1.173.7.4.4.1.1.13 | IpAddress | read-write | mandatory |
| nlIfIpLANCard OBJECT-TYPE The LAN card that contains the interface. This object is only valid when the interface type is LAN based. | 1.3.6.1.4.1.173.7.4.4.1.1.14 | INTEGER (0..1) | read-write | mandatory |
| nlIfIpSourceSub OBJECT-TYPE The subscriber ID associated with the source IP interface port. This object is only valid when the interface type is X.25. | 1.3.6.1.4.1.173.7.4.4.1.1.15 | NlSubscriberAddress | read-write | mandatory |
| nlIfIpDestSub OBJECT-TYPE The subscriber ID associated with the destination IP interface port. This object is only valid when the interface type is X.25. | 1.3.6.1.4.1.173.7.4.4.1.1.16 | NlSubscriberAddress | read-write | mandatory |
| nlIfIpSVCRetryTimer OBJECT-TYPE The frequency with which calls will be placed to try to establish a connection. This object is only valid when the interface type is X.25. | 1.3.6.1.4.1.173.7.4.4.1.1.17 | INTEGER (5..60) | read-write | mandatory |
| nlIfIpSVCIdleTimer OBJECT-TYPE The period that an IP connection remains active with no traffic before the connection is cleared. This object is only valid when the interface type is X.25. | 1.3.6.1.4.1.173.7.4.4.1.1.18 | INTEGER (0..5) | read-write | mandatory |
| nlIfIpMaxSVC OBJECT-TYPE The number of virtual circuits over which IP traffic will be transmitted in parallel. This object is only valid when the interface type is X.25. | 1.3.6.1.4.1.173.7.4.4.1.1.19 | INTEGER (1..8) | read-write | mandatory |
| nlIfIpPVCConnection OBJECT-TYPE The flag which indicates whether this interface is a PVC. This object is only valid when the interface type is X.25. | 1.3.6.1.4.1.173.7.4.4.1.1.20 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| nlIfIpSourceRlp OBJECT-TYPE The RLP of the logical interface of this end of the frame relay link. This object is only valid when the interface type is frame relay. | 1.3.6.1.4.1.173.7.4.4.1.1.21 | INTEGER (1..8) | read-write | mandatory |
| nlIfIpSourcePort OBJECT-TYPE The port of the logical interface of this end of the frame relay link. This object is only valid when the interface type is frame relay. | 1.3.6.1.4.1.173.7.4.4.1.1.22 | INTEGER (1..8) | read-write | mandatory |
| nlIfIpSourceDLCI OBJECT-TYPE The DLCI of the logical interface of this end of the frame relay link. This object is only valid when the interface type is frame relay. | 1.3.6.1.4.1.173.7.4.4.1.1.23 | INTEGER (16..991) | read-write | mandatory |
| nlIfIpRIPSupport OBJECT-TYPE The RIP support that is being run on the interface. | 1.3.6.1.4.1.173.7.4.4.1.1.24 | INTEGER {disabled(1), enabled(2), receive-only(3)} | read-write | mandatory |
| nlIfIpInverseARP OBJECT-TYPE The flag which indicates whether inverse ARP is enabled or disabled. This object is only valid when the interface type is frame relay. | 1.3.6.1.4.1.173.7.4.4.1.1.25 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| nlIfIpProxyARP OBJECT-TYPE The flag which indicates whether proxy ARP is enabled or disabled. This object is only valid when the interface type is LAN based. | 1.3.6.1.4.1.173.7.4.4.1.1.26 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| nlIfIpUnnumberedIf OBJECT-TYPE The flag which indicates whether this interface is an unnumbered interface (i.e., does not require a specific source IP address). This object is only valid when the interface type is frame relay or X.25. | 1.3.6.1.4.1.173.7.4.4.1.1.27 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| nlIfIpRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the nlIfIpTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.4.4.1.1.28 | RowStatus | read-write | mandatory |
| nlIfIpSecondaryAddrTable OBJECT-TYPE A Table to define secondary IP interfaces on a LAN (ethernet, 802.3, 802.5) interface. | 1.3.6.1.4.1.173.7.4.4.2 | not-accessible | mandatory | |
| nlIfIpSecondaryAddrEntry OBJECT-TYPE An IP Secondary Address entry containing objects relating to IP secondary addresses. | 1.3.6.1.4.1.173.7.4.4.2.1 | not-accessible | mandatory | |
| nlIfIpSecondaryAddrSequence OBJECT-TYPE The maximum number of secondary IP addresses that may be configured on an interface. | 1.3.6.1.4.1.173.7.4.4.2.1.1 | INTEGER (1..15) | read-write | mandatory |
| nlIfIpSecondaryAddrNetworkMask OBJECT-TYPE The mask used during routing to determine the portion of the address associated with the network. | 1.3.6.1.4.1.173.7.4.4.2.1.2 | IpAddress | read-write | mandatory |
| nlIfIpSecondaryAddrRouteMetric OBJECT-TYPE The number of network hops (network gateways in the overall path over the internet) associated with this interface. | 1.3.6.1.4.1.173.7.4.4.2.1.3 | INTEGER (0..255) | read-write | mandatory |
| nlIfIpSecondaryAddrSourceAddress OBJECT-TYPE The IP address of the end-to-end sender. | 1.3.6.1.4.1.173.7.4.4.2.1.4 | IpAddress | read-write | mandatory |
| nlIfIpSecondaryAddrBroadcastAddress OBJECT-TYPE The IP address that is used to send to all LAN hosts on the network. | 1.3.6.1.4.1.173.7.4.4.2.1.5 | IpAddress | read-write | mandatory |
| nlIfIpSecondaryAddrRIPSupport OBJECT-TYPE The RIP support that is being run on the interface. | 1.3.6.1.4.1.173.7.4.4.2.1.6 | INTEGER {disabled(1), enabled(2), receive-only(3)} | read-write | mandatory |
| nlIfIpSecondaryAddrRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the nlIfIpSecondaryAddrTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.4.4.2.1.7 | RowStatus | read-write | mandatory |
| nlIfVoiceInterfaces OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.4.5 | |||
| nlIfVoiceTable OBJECT-TYPE A Table to define Voice interfaces over frame relay. | 1.3.6.1.4.1.173.7.4.5.1 | not-accessible | mandatory | |
| nlIfVoiceEntry OBJECT-TYPE A Voice Interface entry containing objects relating to the interface that are configurable by the user. | 1.3.6.1.4.1.173.7.4.5.1.1 | not-accessible | mandatory | |
| nlIfVoiceInterface OBJECT-TYPE The interface number which uniquely identifies the interface to which this entry is applicable. The interface identified by a particular value of this number is NOT the same interface as defined by the same value of ifIndex. | 1.3.6.1.4.1.173.7.4.5.1.1.1 | INTEGER (1..129) | read-only | mandatory |
| nlIfVoicePeerNodeType OBJECT-TYPE The node type for the node at the remote end of the frame relay connection. | 1.3.6.1.4.1.173.7.4.5.1.1.2 | INTEGER {netlink(1), act(2)} | read-write | mandatory |
| nlIfVoicePeerNodeNumber OBJECT-TYPE The node number of the remote device. | 1.3.6.1.4.1.173.7.4.5.1.1.3 | INTEGER (1..61) | read-write | mandatory |
| nlIfVoicePeerNodePort OBJECT-TYPE The voice port on the remote device. | 1.3.6.1.4.1.173.7.4.5.1.1.4 | INTEGER (1..17) | read-write | mandatory |
| nlIfVoiceLocalNodeNumber OBJECT-TYPE The node number of the local device. | 1.3.6.1.4.1.173.7.4.5.1.1.5 | INTEGER (1..61) | read-write | mandatory |
| nlIfVoiceLocalNodePort OBJECT-TYPE The voice port on the local device. | 1.3.6.1.4.1.173.7.4.5.1.1.6 | INTEGER (1..17) | read-write | mandatory |
| nlIfVoiceFrameRelayRlp OBJECT-TYPE The RLP of the logical interface of this end of the frame relay link. | 1.3.6.1.4.1.173.7.4.5.1.1.7 | INTEGER (1..8) | read-write | mandatory |
| nlIfVoiceFrameRelayPort OBJECT-TYPE The port of the logical interface of this end of the frame relay link. | 1.3.6.1.4.1.173.7.4.5.1.1.8 | INTEGER (1..8) | read-write | mandatory |
| nlIfVoiceFrameRelayDLCI OBJECT-TYPE The DLCI of the logical interface of this end of the frame relay link. | 1.3.6.1.4.1.173.7.4.5.1.1.9 | INTEGER (16..991) | read-write | mandatory |
| nlIfVoiceEnableFragment OBJECT-TYPE | 1.3.6.1.4.1.173.7.4.5.1.1.10 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| nlIfVoiceRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the noIfVoiceTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.4.5.1.1.11 | RowStatus | read-write | mandatory |
| subscriber OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.5 | |||
| nlLocalSubscriberTable OBJECT-TYPE A Table to define each local subscriber. | 1.3.6.1.4.1.173.7.5.1 | not-accessible | mandatory | |
| nlLocalSubscriberEntry OBJECT-TYPE A Local Subscriber entry containing objects relating to local subscribers. | 1.3.6.1.4.1.173.7.5.1.1 | not-accessible | mandatory | |
| nlLocalSubscriberId OBJECT-TYPE The Subscriber ID. A valid subscriber ID is a string of numeric digits represented by their ASCII equivalents. The ASCII equivalents of the wildcard characters '*' and '?' are also allowed. A '*' is a wildcard that matches any number of digits, including zero. A '?' is a wildcard that matches any single digit. | 1.3.6.1.4.1.173.7.5.1.1.1 | NlSubscriberAddress | read-only | mandatory |
| nlLocalSubscriberName OBJECT-TYPE The Subscriber name. The subscriber name is not accessible from SNMP, and a blank string is always returned. | 1.3.6.1.4.1.173.7.5.1.1.2 | DisplayString (SIZE(0..31)) | read-only | mandatory |
| nlLocalSubscriberAlgorithm OBJECT-TYPE The Subscriber routing algorithm. The following 4 types of routing algorithms are supported. 1 - round robin selects ports specified cyclicly in numerical order according to the list of Redirection addresses. If the port is unreachable or congested, the call request is sent to the next port. 2. Alternate Route on Line Failure - selects the first port not in a failed state. If a connection is not made, the call will be cleared even if other ports are available. 3. Alternate Route on Line Busy - selects the first port that has LCN's available (not busy). If a port has failed, the next available port is selected. 4. Least LCN with throughput selects the line with the minumum loading, calculated by weight and number of LCN's in use. If use of a routing algorithm is not desired, accept the default and specify only one routing path. | 1.3.6.1.4.1.173.7.5.1.1.3 | INTEGER {round-robin(1), line-failed(2), line-busy(3), least-lcn(4)} | read-write | mandatory |
| nlLocalSubscriberSystematicRedirect OBJECT-TYPE Systematic Redirection. | 1.3.6.1.4.1.173.7.5.1.1.4 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| nlLocalSubscriberRedirectBusy OBJECT-TYPE Redirect calls according to Redirection Addresses if the primary subscriber device is busy. | 1.3.6.1.4.1.173.7.5.1.1.5 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| nlLocalSubscriberRedirectOO OBJECT-TYPE Redirect calls according to Redirection Addresses if the primary subscriber device is out of order. | 1.3.6.1.4.1.173.7.5.1.1.6 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| nlLocalSubscriberPriority OBJECT-TYPE Allows setting a priority for traffic within the node. | 1.3.6.1.4.1.173.7.5.1.1.7 | INTEGER (0..9) | read-write | mandatory |
| nlLocalSubscriberRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the nlLocalSubscriberTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.5.1.1.8 | RowStatus | read-write | mandatory |
| nlLocalSubscriberRouteTable OBJECT-TYPE A Table to define local subscriber route paths. | 1.3.6.1.4.1.173.7.5.2 | not-accessible | mandatory | |
| nlLocalSubscriberRouteEntry OBJECT-TYPE A Local Subscriber Route entry containing objects relating to local subscriber routes. | 1.3.6.1.4.1.173.7.5.2.1 | not-accessible | mandatory | |
| nlLocalSubscriberRouteIndex OBJECT-TYPE Route path index for a specific subscriber route path. | 1.3.6.1.4.1.173.7.5.2.1.1 | INTEGER (1..8) | read-only | mandatory |
| nlLocalSubscriberRouteConf OBJECT-TYPE Flag to indicate if the LP/port routing path to the subscriber device is configured or not. This object is read- only. The route is always configured for an entry in the table. | 1.3.6.1.4.1.173.7.5.2.1.2 | INTEGER {no(1), yes(2)} | read-only | mandatory |
| nlLocalSubscriberRouteLP OBJECT-TYPE Instance of the LP that makes up the routing path | 1.3.6.1.4.1.173.7.5.2.1.3 | INTEGER | read-write | mandatory |
| nlLocalSubscriberRoutePort OBJECT-TYPE Instance of the port that makes up the routing path | 1.3.6.1.4.1.173.7.5.2.1.4 | INTEGER | read-write | mandatory |
| nlLocalSubscriberRouteRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the nlLocalSubscriberRouteTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.5.2.1.5 | RowStatus | read-write | mandatory |
| nlLocalSubscriberRedirTable OBJECT-TYPE A Table to list local subscriber redirection addresses. | 1.3.6.1.4.1.173.7.5.3 | not-accessible | mandatory | |
| nlLocalSubscriberRedirEntry OBJECT-TYPE A Local Subscriber Redirection Address entry containing objects relating to local subscriber redirection addresses. | 1.3.6.1.4.1.173.7.5.3.1 | not-accessible | mandatory | |
| nlLocalSubscriberRedirIndex OBJECT-TYPE Redirection entry index for a local subscriber. | 1.3.6.1.4.1.173.7.5.3.1.1 | INTEGER (1..5) | read-only | mandatory |
| nlLocalSubscriberRedirAddr OBJECT-TYPE Subscriber redirection address. | 1.3.6.1.4.1.173.7.5.3.1.2 | NlSubscriberAddress | read-write | mandatory |
| nlLocalSubscriberRedirRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the nlLocalSubscriberRedirTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.5.3.1.3 | RowStatus | read-write | mandatory |
| llc2 OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.6 | |||
| nlLlc2HostTable OBJECT-TYPE A Table to define LLC2 host entries. | 1.3.6.1.4.1.173.7.6.1 | not-accessible | mandatory | |
| nlLlc2HostEntry OBJECT-TYPE An LLC2 Host entry containing objects relating to LLC2 hosts. | 1.3.6.1.4.1.173.7.6.1.1 | not-accessible | mandatory | |
| nlLlc2HostIndex OBJECT-TYPE LLC2 Host Index | 1.3.6.1.4.1.173.7.6.1.1.1 | INTEGER (1..251) | read-only | mandatory |
| nlLlc2HostMACAddress OBJECT-TYPE The LLC2 Host MAC Address. | 1.3.6.1.4.1.173.7.6.1.1.2 | MacAddress | read-write | mandatory |
| nlLlc2HostSessionType OBJECT-TYPE The mode in which the Host is operating | 1.3.6.1.4.1.173.7.6.1.1.3 | INTEGER {originated(1), terminated(2)} | read-write | mandatory |
| nlLlc2HostT1ReplyTimer OBJECT-TYPE Reply Timer used to detect a failure of the Remote node. | 1.3.6.1.4.1.173.7.6.1.1.4 | TimeInterval (1..250) | read-write | mandatory |
| nlLlc2HostT2RecvAckTimer OBJECT-TYPE Receive Ack Timer used to delay sending an acknowledgement of a received information LPDU. | 1.3.6.1.4.1.173.7.6.1.1.5 | TimeInterval (100..5000) | read-write | mandatory |
| nlLlc2HostTiInactivityTimer OBJECT-TYPE Timer used to detect inoperative condition of the remote link station or transmission medium. | 1.3.6.1.4.1.173.7.6.1.1.6 | TimeInterval (1..50) | read-write | mandatory |
| nlLlc2HostN3NumberLPDUs OBJECT-TYPE The number of Information LPDUs that need to be received before an acknowledgement is sent. | 1.3.6.1.4.1.173.7.6.1.1.7 | INTEGER (1..127) | read-write | mandatory |
| nlLlc2HostTwNumberOutstanding OBJECT-TYPE Maximum number of sequentially numbered information LPDUs that can be outstanding at any time. | 1.3.6.1.4.1.173.7.6.1.1.8 | INTEGER (1..127) | read-write | mandatory |
| nlLlc2HostN2ExpiredT1LPDUCount OBJECT-TYPE Maximum number of LPDU retransmissions occur following the expiration of Timer T1. | 1.3.6.1.4.1.173.7.6.1.1.9 | INTEGER (0..255) | read-write | mandatory |
| nlLlc2HostPriority OBJECT-TYPE Traffic priorities within the node. | 1.3.6.1.4.1.173.7.6.1.1.10 | INTEGER (0..9) | read-write | mandatory |
| nlLlc2HostBAG OBJECT-TYPE Bandwidth Allocation group to which the LLC2 Host belongs. This object is read-only. Bandwidth allocation groups do not apply to LLC2 hosts. | 1.3.6.1.4.1.173.7.6.1.1.11 | INTEGER (1..16) | read-only | mandatory |
| nlLlc2HostRoutingSubscriberId OBJECT-TYPE LLC2 hosts Routing Subscriber Id | 1.3.6.1.4.1.173.7.6.1.1.12 | NlSubscriberAddress | read-write | mandatory |
| nlLlc2HostSrcMACAddressMask OBJECT-TYPE LLC2 Host's Source MAC Address Mask | 1.3.6.1.4.1.173.7.6.1.1.13 | MacAddress | read-write | mandatory |
| nlLlc2HostAccess OBJECT-TYPE Specifies different type(s) of interface(s) that can be used for connections to a terminated host session. | 1.3.6.1.4.1.173.7.6.1.1.14 | INTEGER {lan(1), frameRelay(2), tokenRing(3), ethernet(4), all(5), not-applicable(6)} | read-only | mandatory |
| nlLlc2HostRowStatus OBJECT-TYPE Row status convention for LLC2 Host entry. | 1.3.6.1.4.1.173.7.6.1.1.15 | RowStatus | read-write | mandatory |
| nlLlc2HostInterface OBJECT-TYPE LLC2 interface number associated with this host entry, always 300 for non-FRX7000. | 1.3.6.1.4.1.173.7.6.1.1.16 | INTEGER | read-only | mandatory |
| nlLlc2HostGroup OBJECT-TYPE Traffic group associated with LLC2 interface, always 1 for non-FRX7000. | 1.3.6.1.4.1.173.7.6.1.1.17 | INTEGER (1..4) | read-only | mandatory |
| nlLlc2TermConnectionTable OBJECT-TYPE A Table to describe LLC2 Terminated Host Connections. | 1.3.6.1.4.1.173.7.6.2 | not-accessible | mandatory | |
| nlLlc2TermConnectionEntry OBJECT-TYPE An LLC2 Terminated Host Connection entry containing objects relating to LLC2 terminated host connections. | 1.3.6.1.4.1.173.7.6.2.1 | not-accessible | mandatory | |
| nlLlc2TermConnectionSequence OBJECT-TYPE LLC2 Host connection Sequence number | 1.3.6.1.4.1.173.7.6.2.1.1 | INTEGER (1..16) | read-only | mandatory |
| nlLlc2TermConnectionHSAP OBJECT-TYPE Service Access point used to connect to the Host | 1.3.6.1.4.1.173.7.6.2.1.2 | INTEGER (4..254) | read-write | mandatory |
| nlLlc2TermConnectionLocalSubscriberId OBJECT-TYPE LLC2 Host Connection's Local Subscriber Id | 1.3.6.1.4.1.173.7.6.2.1.3 | NlSubscriberAddress | read-write | mandatory |
| nlLlc2TermConnectionRemoteSubscriberId OBJECT-TYPE LLC2 Host Connection's Remote Subscriber Id | 1.3.6.1.4.1.173.7.6.2.1.4 | NlSubscriberAddress | read-write | mandatory |
| nlLlc2TermConnectionRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the nlLlc2TermConnectionTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.6.2.1.5 | RowStatus | read-write | mandatory |
| nlLlc2OrigConnectionTable OBJECT-TYPE A Table to describe LLC2 Originated Host Connections. | 1.3.6.1.4.1.173.7.6.3 | not-accessible | mandatory | |
| nlLlc2OrigConnectionEntry OBJECT-TYPE An LLC2 Originated Host Connection entry containing objects relating to LLC2 originated host connections. | 1.3.6.1.4.1.173.7.6.3.1 | not-accessible | mandatory | |
| nlLlc2OrigConnectionSequence OBJECT-TYPE LLC2 Host connection Sequence number | 1.3.6.1.4.1.173.7.6.3.1.1 | INTEGER (1..16) | read-only | mandatory |
| nlLlc2OrigConnectionHSAP OBJECT-TYPE Service Access point used to connect to the Host | 1.3.6.1.4.1.173.7.6.3.1.2 | INTEGER (4..254) | read-write | mandatory |
| nlLlc2OrigConnectionType OBJECT-TYPE Specifies Remote subscriber device type | 1.3.6.1.4.1.173.7.6.3.1.3 | INTEGER {sdlc(1), llc2(2)} | read-write | mandatory |
| nlLlc2OrigConnectionLocalSubscriberId OBJECT-TYPE LLC2 Host Connection's Local Subscriber Id | 1.3.6.1.4.1.173.7.6.3.1.4 | NlSubscriberAddress | read-write | mandatory |
| nlLlc2OrigConnectionRemoteSubscriberId OBJECT-TYPE LLC2 Host Connection's Remote Subscriber Id | 1.3.6.1.4.1.173.7.6.3.1.5 | NlSubscriberAddress | read-write | mandatory |
| nlLlc2OrigConnectionIDBLK OBJECT-TYPE This field is obsolete | 1.3.6.1.4.1.173.7.6.3.1.6 | INTEGER | read-only | mandatory |
| nlLlc2OrigConnectionIDNUM OBJECT-TYPE This field is obsolete | 1.3.6.1.4.1.173.7.6.3.1.7 | INTEGER | read-only | mandatory |
| nlLlc2OrigConnectionMAXDATA OBJECT-TYPE This field is obsolete | 1.3.6.1.4.1.173.7.6.3.1.8 | INTEGER | read-only | mandatory |
| nlLlc2OrigConnectionMAXIN OBJECT-TYPE This field is obsolete | 1.3.6.1.4.1.173.7.6.3.1.9 | INTEGER | read-only | mandatory |
| nlLlc2OrigConnectionRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the nlLlc2OrigConnectionTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.6.3.1.10 | RowStatus | read-write | mandatory |
| nlLlc2NextHostNumber OBJECT-TYPE The host number to be used for the next created host record, always 1 on non-FRX7000. | 1.3.6.1.4.1.173.7.6.4 | INTEGER | read-only | mandatory |
| status OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.7 | |||
| pinStatusTable OBJECT-TYPE A Table to describe the status of each pin on a physical port. This table is indexed by RLP and Port | 1.3.6.1.4.1.173.7.7.4 | not-accessible | mandatory | |
| portPinEntry OBJECT-TYPE A port pin entry containing objects relating to ports. | 1.3.6.1.4.1.173.7.7.4.1 | not-accessible | mandatory | |
| portPinRlp OBJECT-TYPE The RLP number on the node | 1.3.6.1.4.1.173.7.7.4.1.1 | INTEGER | read-only | mandatory |
| portPinPort OBJECT-TYPE The Port number on the RLP. Port numbers 0-7 are known to be physical ports. | 1.3.6.1.4.1.173.7.7.4.1.2 | INTEGER | read-only | mandatory |
| portPinStatus OBJECT-TYPE The status of all pins for this physical port. There is one octet value for each of the pins. Each octet value is defined as follows: 00 = unknown 01 = active 02 = inactive 03 = unused | 1.3.6.1.4.1.173.7.7.4.1.3 | OCTET STRING | read-only | mandatory |
| statistics OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.8 | |||
| statGroup OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.8.1 | |||
| rlpStatsTable OBJECT-TYPE A Table to describe Statistics on each RLP | 1.3.6.1.4.1.173.7.8.1.2 | not-accessible | mandatory | |
| rlpStatsEntry OBJECT-TYPE An RLP statistics entry containing objects relating to RLP statistics. | 1.3.6.1.4.1.173.7.8.1.2.1 | not-accessible | mandatory | |
| rlpStatsIndex OBJECT-TYPE The RLP number | 1.3.6.1.4.1.173.7.8.1.2.1.1 | INTEGER | read-only | mandatory |
| rlpStatsQMessages OBJECT-TYPE The number of frames queued on the RLP | 1.3.6.1.4.1.173.7.8.1.2.1.2 | Counter | read-only | mandatory |
| rlpStatsUsedBuffers OBJECT-TYPE The percentage of total buffers available being used at the moment of inquiry | 1.3.6.1.4.1.173.7.8.1.2.1.3 | Counter | read-only | mandatory |
| rlpStatsInFrames OBJECT-TYPE The number of frames received. | 1.3.6.1.4.1.173.7.8.1.2.1.4 | Counter | read-only | mandatory |
| rlpStatsOutFrames OBJECT-TYPE The number of frames transmitted. | 1.3.6.1.4.1.173.7.8.1.2.1.5 | Counter | read-only | mandatory |
| rlpStatsFrameRejects OBJECT-TYPE The number of frames rejected. | 1.3.6.1.4.1.173.7.8.1.2.1.6 | Counter | read-only | mandatory |
| rlpStatsFrameRetransmits OBJECT-TYPE The number of frames retransmitted . If this value is consistently greater than zero and there are no other problems, then increase the retransmission parameter. | 1.3.6.1.4.1.173.7.8.1.2.1.7 | Counter | read-only | mandatory |
| portStatsTable OBJECT-TYPE A Table to describe Statistics on each RLP | 1.3.6.1.4.1.173.7.8.1.3 | not-accessible | mandatory | |
| portStatsEntry OBJECT-TYPE A port statistics entry containing objects relating to port statistics. | 1.3.6.1.4.1.173.7.8.1.3.1 | not-accessible | mandatory | |
| portStatsRlpIndex OBJECT-TYPE The RLP number | 1.3.6.1.4.1.173.7.8.1.3.1.1 | INTEGER | read-only | mandatory |
| portStatsIndex OBJECT-TYPE The Port number | 1.3.6.1.4.1.173.7.8.1.3.1.2 | INTEGER | read-only | mandatory |
| portStatsInFrames OBJECT-TYPE The number of frames received. | 1.3.6.1.4.1.173.7.8.1.3.1.3 | Counter | read-only | mandatory |
| portStatsOutFrames OBJECT-TYPE The number of frames transmitted. | 1.3.6.1.4.1.173.7.8.1.3.1.4 | Counter | read-only | mandatory |
| portStatsFrameRetrans OBJECT-TYPE The number of frames retransmitted. | 1.3.6.1.4.1.173.7.8.1.3.1.5 | Counter | read-only | mandatory |
| portStatsFCSErrors OBJECT-TYPE The number of Frame Check Sequence (FCS) errors. A value consistently greater than zero indicates line probelms. | 1.3.6.1.4.1.173.7.8.1.3.1.6 | Counter | read-only | mandatory |
| portStatsLogicalRejects OBJECT-TYPE The sum of Rejects and Frame Rejects. A value consistently greater than zero indicates line probelms. | 1.3.6.1.4.1.173.7.8.1.3.1.7 | Counter | read-only | mandatory |
| portStatsInPercentUtils OBJECT-TYPE The ratio of non-flag characters to total characters being received by the port. | 1.3.6.1.4.1.173.7.8.1.3.1.8 | Counter | read-only | mandatory |
| portStatsOutPercentUtils OBJECT-TYPE The ration of non-flag characters to total characters being transmitted by the port. | 1.3.6.1.4.1.173.7.8.1.3.1.9 | Counter | read-only | mandatory |
| statFrame OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.8.1.4 | |||
| frStatsTable OBJECT-TYPE A Table to describe Frame Relay Frame Level Statistics on each Port | 1.3.6.1.4.1.173.7.8.1.4.1 | not-accessible | mandatory | |
| frStatsEntry OBJECT-TYPE A frame relay port statistics entry containing objects relating to frame relay port statistics. | 1.3.6.1.4.1.173.7.8.1.4.1.1 | not-accessible | mandatory | |
| frStatsRlpIndex OBJECT-TYPE The RLP Number. | 1.3.6.1.4.1.173.7.8.1.4.1.1.1 | INTEGER | read-only | mandatory |
| frStatsPortIndex OBJECT-TYPE The Port number. | 1.3.6.1.4.1.173.7.8.1.4.1.1.2 | INTEGER | read-only | mandatory |
| frStatsTxDEFrames OBJECT-TYPE The number of frames transmitted on the port with the Discard Eligibility bit set. | 1.3.6.1.4.1.173.7.8.1.4.1.1.3 | Counter | read-only | mandatory |
| frStatsRxDEFrames OBJECT-TYPE The number of frames received on the port with the discard eligibility bit set. | 1.3.6.1.4.1.173.7.8.1.4.1.1.4 | Counter | read-only | mandatory |
| frStatsTxFECNFrames OBJECT-TYPE The of number of frames transmitted on the port with FECN. | 1.3.6.1.4.1.173.7.8.1.4.1.1.5 | Counter | read-only | mandatory |
| frStatsRxFECNFrames OBJECT-TYPE The number of frames received on the port with FECN. | 1.3.6.1.4.1.173.7.8.1.4.1.1.6 | Counter | read-only | mandatory |
| frStatsTxBECNFrames OBJECT-TYPE The number of frames transmitted on the port with BECN. | 1.3.6.1.4.1.173.7.8.1.4.1.1.7 | Counter | read-only | mandatory |
| frStatsRxBECNFrames OBJECT-TYPE The number of frames received on the port with BECN. | 1.3.6.1.4.1.173.7.8.1.4.1.1.8 | Counter | read-only | mandatory |
| frStatsTxLMIFrames OBJECT-TYPE The number of LMI frames transmitted on the port. | 1.3.6.1.4.1.173.7.8.1.4.1.1.9 | Counter | read-only | mandatory |
| frStatsRxLMIFrames OBJECT-TYPE The number of LMI frames received on the port. | 1.3.6.1.4.1.173.7.8.1.4.1.1.10 | Counter | read-only | mandatory |
| frStatsTxANXDFrames OBJECT-TYPE The number of AnnexD frames transmitted on the port | 1.3.6.1.4.1.173.7.8.1.4.1.1.11 | Counter | read-only | mandatory |
| frStatsRxANXDFrames OBJECT-TYPE The number of AnnexD frames received on the port | 1.3.6.1.4.1.173.7.8.1.4.1.1.12 | Counter | read-only | mandatory |
| frStatsTotDiscFrames OBJECT-TYPE The total number of discarded frames on the port. | 1.3.6.1.4.1.173.7.8.1.4.1.1.13 | Counter | read-only | mandatory |
| x25TxStatsTable OBJECT-TYPE A Table to describe X25 Frame Level Txmit Statistics on each Port | 1.3.6.1.4.1.173.7.8.1.4.2 | not-accessible | mandatory | |
| x25TxStatsEntry OBJECT-TYPE An X25 frame level transmit statistics entry containing objects relating to x25 frame level transmit statistics. | 1.3.6.1.4.1.173.7.8.1.4.2.1 | not-accessible | mandatory | |
| x25TxRlpIndex OBJECT-TYPE The RLP Number. | 1.3.6.1.4.1.173.7.8.1.4.2.1.1 | INTEGER | read-only | mandatory |
| x25TxPortIndex OBJECT-TYPE The Port number. | 1.3.6.1.4.1.173.7.8.1.4.2.1.2 | INTEGER | read-only | mandatory |
| x25TxSABMFrames OBJECT-TYPE The number of SABM's transmitted on the port. | 1.3.6.1.4.1.173.7.8.1.4.2.1.3 | Counter | read-only | mandatory |
| x25TxUAFrames OBJECT-TYPE The number of UA Frames transmitted on the port. | 1.3.6.1.4.1.173.7.8.1.4.2.1.4 | Counter | read-only | mandatory |
| x25TxDISCFrames OBJECT-TYPE The number of DISC Frames transmitted on the port. | 1.3.6.1.4.1.173.7.8.1.4.2.1.5 | Counter | read-only | mandatory |
| x25TxDMFrames OBJECT-TYPE The number of DM frames transmitted on the port. | 1.3.6.1.4.1.173.7.8.1.4.2.1.6 | Counter | read-only | mandatory |
| x25TxFRMRFrames OBJECT-TYPE The of Number of FRMR frames transmitted on the port. | 1.3.6.1.4.1.173.7.8.1.4.2.1.7 | Counter | read-only | mandatory |
| x25TxREJFrames OBJECT-TYPE The number of Reject Frames transmitted on the port. | 1.3.6.1.4.1.173.7.8.1.4.2.1.8 | Counter | read-only | mandatory |
| x25TxRRFrames OBJECT-TYPE The number of RR frames transmitted on the port. | 1.3.6.1.4.1.173.7.8.1.4.2.1.9 | Counter | read-only | mandatory |
| x25TxRNRFrames OBJECT-TYPE The number of RNR Frames transmitted on the port. | 1.3.6.1.4.1.173.7.8.1.4.2.1.10 | Counter | read-only | mandatory |
| x25TxINFOFrames OBJECT-TYPE The number of INFO Frames transmitted on the port | 1.3.6.1.4.1.173.7.8.1.4.2.1.11 | Counter | read-only | mandatory |
| x25RxStatsTable OBJECT-TYPE A Table to describe X25 Frame Level Rxmit Statistics on each Port | 1.3.6.1.4.1.173.7.8.1.4.3 | not-accessible | mandatory | |
| x25RxStatsEntry OBJECT-TYPE An X25 frame level receive statistics entry containing objects relating to x25 frame level receive statistics. | 1.3.6.1.4.1.173.7.8.1.4.3.1 | not-accessible | mandatory | |
| x25RxRlpIndex OBJECT-TYPE The RLP Number. | 1.3.6.1.4.1.173.7.8.1.4.3.1.1 | INTEGER | read-only | mandatory |
| x25RxPortIndex OBJECT-TYPE The Port number. | 1.3.6.1.4.1.173.7.8.1.4.3.1.2 | INTEGER | read-only | mandatory |
| x25RxSABMFrames OBJECT-TYPE The number of SABM's received on the port. | 1.3.6.1.4.1.173.7.8.1.4.3.1.3 | Counter | read-only | mandatory |
| x25RxUAFrames OBJECT-TYPE The number of UA Frames received on the port. | 1.3.6.1.4.1.173.7.8.1.4.3.1.4 | Counter | read-only | mandatory |
| x25RxDISCFrames OBJECT-TYPE The number of DISC Frames received on the port. | 1.3.6.1.4.1.173.7.8.1.4.3.1.5 | Counter | read-only | mandatory |
| x25RxDMFrames OBJECT-TYPE The number of DM frames received on the port. | 1.3.6.1.4.1.173.7.8.1.4.3.1.6 | Counter | read-only | mandatory |
| x25RxFRMRFrames OBJECT-TYPE The of Number of FRMR frames received on the port. | 1.3.6.1.4.1.173.7.8.1.4.3.1.7 | Counter | read-only | mandatory |
| x25RxREJFrames OBJECT-TYPE The number of Reject Frames received on the port. | 1.3.6.1.4.1.173.7.8.1.4.3.1.8 | Counter | read-only | mandatory |
| x25RxRRFrames OBJECT-TYPE The number of RR frames received on the port. | 1.3.6.1.4.1.173.7.8.1.4.3.1.9 | Counter | read-only | mandatory |
| x25RxRNRFrames OBJECT-TYPE The number of RNR Frames received on the port. | 1.3.6.1.4.1.173.7.8.1.4.3.1.10 | Counter | read-only | mandatory |
| x25RxINFOFrames OBJECT-TYPE The number of INFO Frames received on the port | 1.3.6.1.4.1.173.7.8.1.4.3.1.11 | Counter | read-only | mandatory |
| statBag OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.8.1.5 | |||
| statIp OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.8.1.6 | |||
| statT1 OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.8.1.7 | |||
| t1StatsTable OBJECT-TYPE A Table to describe T1 Statistics. | 1.3.6.1.4.1.173.7.8.1.7.1 | not-accessible | mandatory | |
| t1StatsEntry OBJECT-TYPE A T1 port statistics entry containing objects relating to T1 port statistics. | 1.3.6.1.4.1.173.7.8.1.7.1.1 | not-accessible | mandatory | |
| t1StatsRlpIndex OBJECT-TYPE The RLP Number. | 1.3.6.1.4.1.173.7.8.1.7.1.1.1 | INTEGER | read-only | mandatory |
| t1StatsPortIndex OBJECT-TYPE The Port Number. | 1.3.6.1.4.1.173.7.8.1.7.1.1.2 | INTEGER | read-only | mandatory |
| t1StatsRcvFrames OBJECT-TYPE Total received frames. | 1.3.6.1.4.1.173.7.8.1.7.1.1.3 | Counter | read-only | mandatory |
| t1StatsXmitFrames OBJECT-TYPE Total transmitted frames. | 1.3.6.1.4.1.173.7.8.1.7.1.1.4 | Counter | read-only | mandatory |
| t1StatsLCVCnt OBJECT-TYPE Line code violation count. | 1.3.6.1.4.1.173.7.8.1.7.1.1.5 | Counter | read-only | mandatory |
| t1StatsPCVRErrs OBJECT-TYPE PCVR Bit error count. | 1.3.6.1.4.1.173.7.8.1.7.1.1.6 | Counter | read-only | mandatory |
| t1StatsOOSCnt OBJECT-TYPE Multiframe out of sync count. | 1.3.6.1.4.1.173.7.8.1.7.1.1.7 | Counter | read-only | mandatory |
| t1StatsBlueAlarms OBJECT-TYPE Blue alarm count. | 1.3.6.1.4.1.173.7.8.1.7.1.1.8 | Counter | read-only | mandatory |
| t1StatsYellowAlarms OBJECT-TYPE Yellow alarm count. | 1.3.6.1.4.1.173.7.8.1.7.1.1.9 | Counter | read-only | mandatory |
| t1StatsRedAlarms OBJECT-TYPE Red alarm count. | 1.3.6.1.4.1.173.7.8.1.7.1.1.10 | Counter | read-only | mandatory |
| t1StatsRcvUsage OBJECT-TYPE Receive port utilization. | 1.3.6.1.4.1.173.7.8.1.7.1.1.11 | Counter | read-only | mandatory |
| t1StatsXmitUsage OBJECT-TYPE Transmit port utilization. | 1.3.6.1.4.1.173.7.8.1.7.1.1.12 | Counter | read-only | mandatory |
| t1StatsXmitAbortFrames OBJECT-TYPE Total aborted transmit frames. | 1.3.6.1.4.1.173.7.8.1.7.1.1.13 | Counter | read-only | mandatory |
| t1StatsRcvAbortFrames OBJECT-TYPE Total aborted receive frames. | 1.3.6.1.4.1.173.7.8.1.7.1.1.14 | Counter | read-only | mandatory |
| t1StatsRcvOverruns OBJECT-TYPE Total receive overruns. | 1.3.6.1.4.1.173.7.8.1.7.1.1.15 | Counter | read-only | mandatory |
| t1StatsRcvErrors OBJECT-TYPE Total bad receives. | 1.3.6.1.4.1.173.7.8.1.7.1.1.16 | Counter | read-only | mandatory |
| t1StatsRcvChannelErrors OBJECT-TYPE Total bad receives. | 1.3.6.1.4.1.173.7.8.1.7.1.1.17 | Counter | read-only | mandatory |
| statDS0A OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.8.1.8 | |||
| ds0aStatsTable OBJECT-TYPE A Table to describe DS0A Statistics. | 1.3.6.1.4.1.173.7.8.1.8.1 | not-accessible | mandatory | |
| ds0aStatsEntry OBJECT-TYPE A DS0A port statistics entry containing objects relating to DS0A port statistics. | 1.3.6.1.4.1.173.7.8.1.8.1.1 | not-accessible | mandatory | |
| ds0aStatsRlpIndex OBJECT-TYPE The RLP Number. | 1.3.6.1.4.1.173.7.8.1.8.1.1.1 | INTEGER | read-only | mandatory |
| ds0aStatsPortIndex OBJECT-TYPE The Port Number. | 1.3.6.1.4.1.173.7.8.1.8.1.1.2 | INTEGER | read-only | mandatory |
| ds0aStatsChannelIndex OBJECT-TYPE The Channel Number. | 1.3.6.1.4.1.173.7.8.1.8.1.1.3 | INTEGER | read-only | mandatory |
| ds0aStatsXmitFrames OBJECT-TYPE Total transmitted frames. | 1.3.6.1.4.1.173.7.8.1.8.1.1.4 | Counter | read-only | mandatory |
| ds0aStatsRcvFrames OBJECT-TYPE Total received frames. | 1.3.6.1.4.1.173.7.8.1.8.1.1.5 | Counter | read-only | mandatory |
| ds0aStatsRcvAbortFrames OBJECT-TYPE Total receive aborted frames. | 1.3.6.1.4.1.173.7.8.1.8.1.1.6 | Counter | read-only | mandatory |
| ds0aStatsRcvOverruns OBJECT-TYPE Total receive overruns. | 1.3.6.1.4.1.173.7.8.1.8.1.1.7 | Counter | read-only | mandatory |
| ds0aStatsRcvErrors OBJECT-TYPE Total receive errors. | 1.3.6.1.4.1.173.7.8.1.8.1.1.8 | Counter | read-only | mandatory |
| statVoice OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.8.1.9 | |||
| voiceStatsTable OBJECT-TYPE A Table to describe Voice over Frame Relay Statistics. | 1.3.6.1.4.1.173.7.8.1.9.1 | not-accessible | mandatory | |
| voiceStatsEntry OBJECT-TYPE A voice port statistics entry containing objects relating to voice port statistics. | 1.3.6.1.4.1.173.7.8.1.9.1.1 | not-accessible | mandatory | |
| voiceStatsRlpIndex OBJECT-TYPE The RLP Number. | 1.3.6.1.4.1.173.7.8.1.9.1.1.1 | INTEGER | read-only | mandatory |
| voiceStatsPortIndex OBJECT-TYPE The Port Number. | 1.3.6.1.4.1.173.7.8.1.9.1.1.2 | INTEGER | read-only | mandatory |
| voiceStatsRxCalls OBJECT-TYPE The Number of Calls Received from the Network. | 1.3.6.1.4.1.173.7.8.1.9.1.1.3 | Counter | read-only | mandatory |
| voiceStatsTxCalls OBJECT-TYPE The Number of Calls Transmitted to the Network. | 1.3.6.1.4.1.173.7.8.1.9.1.1.4 | Counter | read-only | mandatory |
| voiceStatsRxCallsAccepts OBJECT-TYPE The Number of Call Accepts Received from the Network. | 1.3.6.1.4.1.173.7.8.1.9.1.1.5 | Counter | read-only | mandatory |
| voiceStatsTxCallsAccepts OBJECT-TYPE The Number of Call Accepts Transmitted to the Network. | 1.3.6.1.4.1.173.7.8.1.9.1.1.6 | Counter | read-only | mandatory |
| voiceStatsRxClears OBJECT-TYPE The Number of Call Receives cleared. | 1.3.6.1.4.1.173.7.8.1.9.1.1.7 | Counter | read-only | mandatory |
| voiceStatsTxClears OBJECT-TYPE The Number of Call Transmitts cleared. | 1.3.6.1.4.1.173.7.8.1.9.1.1.8 | Counter | read-only | mandatory |
| voiceStatsBusyCalls OBJECT-TYPE The Number of calls which received Busy indication. | 1.3.6.1.4.1.173.7.8.1.9.1.1.9 | Counter | read-only | mandatory |
| voiceStatsCallTimeouts OBJECT-TYPE The Number of calls which transmitted time-out to the network. | 1.3.6.1.4.1.173.7.8.1.9.1.1.10 | Counter | read-only | mandatory |
| voiceStatsRxCongestions OBJECT-TYPE The number of congestion management frames Received. | 1.3.6.1.4.1.173.7.8.1.9.1.1.11 | Counter | read-only | mandatory |
| voiceStatsTxCongestions OBJECT-TYPE The number of congestion management frames Transmitted. | 1.3.6.1.4.1.173.7.8.1.9.1.1.12 | Counter | read-only | mandatory |
| statThresh OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.8.2 | |||
| rlpThreshTable OBJECT-TYPE A Table to describe Statistic thresholds on each RLP | 1.3.6.1.4.1.173.7.8.2.1 | not-accessible | mandatory | |
| rlpThreshEntry OBJECT-TYPE An RLP statistics threshold entry containing objects relating to RLP statistics thresholds. | 1.3.6.1.4.1.173.7.8.2.1.1 | not-accessible | mandatory | |
| rlpThreshRlpIndex OBJECT-TYPE The RLP Number. | 1.3.6.1.4.1.173.7.8.2.1.1.1 | INTEGER | read-only | mandatory |
| rlpThreshPercntBufInUse OBJECT-TYPE The threshold for Percent of Buffers in use on the RLP | 1.3.6.1.4.1.173.7.8.2.1.1.2 | INTEGER | read-only | mandatory |
| rlpThreshMsgQueueLen OBJECT-TYPE The threshold for Percent of Buffers in use on the RLP | 1.3.6.1.4.1.173.7.8.2.1.1.3 | INTEGER | read-only | mandatory |
| rlpThreshRxFramesPerSec OBJECT-TYPE The threshold for Rcvd frames per second on the RLP | 1.3.6.1.4.1.173.7.8.2.1.1.4 | INTEGER | read-only | mandatory |
| rlpThreshTxFramesPerSec OBJECT-TYPE The threshold for Txmitted frames per second on the RLP | 1.3.6.1.4.1.173.7.8.2.1.1.5 | INTEGER | read-only | mandatory |
| rlpThreshRejFramesPerSec OBJECT-TYPE The threshold for Rejected Frames per second on the RLP | 1.3.6.1.4.1.173.7.8.2.1.1.6 | INTEGER | read-only | mandatory |
| rlpThreshRtxFramesPerSec OBJECT-TYPE The threshold for Retransmitted frames per second on the RLP | 1.3.6.1.4.1.173.7.8.2.1.1.7 | INTEGER | read-only | mandatory |
| portThreshTable OBJECT-TYPE A Table to describe Statistic thresholds on each port | 1.3.6.1.4.1.173.7.8.2.2 | not-accessible | mandatory | |
| portThreshEntry OBJECT-TYPE A port statistics threshold entry containing objects relating to port statistics thresholds. | 1.3.6.1.4.1.173.7.8.2.2.1 | not-accessible | mandatory | |
| portThreshRlpIndex OBJECT-TYPE The RLP Number. | 1.3.6.1.4.1.173.7.8.2.2.1.1 | INTEGER | read-only | mandatory |
| portThreshIndex OBJECT-TYPE The Port Number. | 1.3.6.1.4.1.173.7.8.2.2.1.2 | INTEGER | read-only | mandatory |
| portThreshRxFramesPerSec OBJECT-TYPE The threshold for Rcvd frames per second on the port. | 1.3.6.1.4.1.173.7.8.2.2.1.3 | INTEGER | read-only | mandatory |
| portThreshTxFramesPerSec OBJECT-TYPE The threshold for Txmitted frames per second on the port. | 1.3.6.1.4.1.173.7.8.2.2.1.4 | INTEGER | read-only | mandatory |
| portThreshRtxFramesPerSec OBJECT-TYPE The threshold for Retransmitted frames per second on the port. | 1.3.6.1.4.1.173.7.8.2.2.1.5 | INTEGER | read-only | mandatory |
| portThreshFCSErrPerSec OBJECT-TYPE The threshold for FCS errors per second on the port. | 1.3.6.1.4.1.173.7.8.2.2.1.6 | INTEGER | read-only | mandatory |
| portThreshLogRejPerSec OBJECT-TYPE The threshold for Logical Rejects per second on the port. | 1.3.6.1.4.1.173.7.8.2.2.1.7 | INTEGER | read-only | mandatory |
| portThreshTxErrorRatio OBJECT-TYPE The threshold for Txmit error ratio on the port. | 1.3.6.1.4.1.173.7.8.2.2.1.8 | INTEGER | read-only | mandatory |
| portThreshRxErrorRatio OBJECT-TYPE The threshold for Rcv error ratio on the port. | 1.3.6.1.4.1.173.7.8.2.2.1.9 | INTEGER | read-only | mandatory |
| portThreshTxPercentUtl OBJECT-TYPE The threshold for Txmit percent utilization on the port. | 1.3.6.1.4.1.173.7.8.2.2.1.10 | INTEGER | read-only | mandatory |
| portThreshRxPercentUtl OBJECT-TYPE The threshold for Rcv percent utilization on the port. | 1.3.6.1.4.1.173.7.8.2.2.1.11 | INTEGER | read-only | mandatory |
| bridge OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.9 | |||
| bridgeAdminVirtualLANID OBJECT-TYPE LAN id inserted into token ring RIF field representing internal virtual ring, for LLC2 or bridged traffic | 1.3.6.1.4.1.173.7.9.1 | INTEGER (0..4095) | read-write | mandatory |
| bridgeOperVirtualLANID OBJECT-TYPE LAN id inserted into token ring RIF field representing internal virtual ring, for LLC2 or bridged traffic | 1.3.6.1.4.1.173.7.9.2 | INTEGER (0..4095) | read-only | mandatory |
| bridgeEnabled OBJECT-TYPE When yes the spanning tree algorithm is in effect and all traffic types may be bridged. When no only llc/2 terminated traffic is allowed on bridge interfaces. | 1.3.6.1.4.1.173.7.9.3 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| bridgeMaxSizeForwardingTable OBJECT-TYPE Number of entries allowed in the bridge forwarding table | 1.3.6.1.4.1.173.7.9.4 | INTEGER (128..65535) | read-write | mandatory |
| bridgeIPEnabled OBJECT-TYPE When yes, and BRIDGING ENABLED, IP traffic will be bridged, otherwise IP traffic will be routed. | 1.3.6.1.4.1.173.7.9.5 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| bridgeIPXEnabled OBJECT-TYPE When yes, and BRIDGING ENABLED, IPX traffic will be bridged, otherwise IPX traffic will be routed. | 1.3.6.1.4.1.173.7.9.6 | INTEGER {no(1), yes(2)} | read-write | mandatory |
| bridgeAdminSRBID OBJECT-TYPE bridge ID to be inserted into token ring RIF field, this bridge | 1.3.6.1.4.1.173.7.9.7 | INTEGER (0..15) | read-write | mandatory |
| bridgeOperSRBID OBJECT-TYPE bridge ID to be inserted into token ring RIF field, this bridge | 1.3.6.1.4.1.173.7.9.8 | INTEGER (0..15) | read-only | mandatory |
| bridgeDefaultEthernetFrameType OBJECT-TYPE default frame type to be used when forwarding traffic on ethernet interfaces. | 1.3.6.1.4.1.173.7.9.9 | INTEGER {type-II(1), ieee8023(2)} | read-write | mandatory |
| ipNl OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.11 | |||
| nlIpDefaultRIPVersion OBJECT-TYPE The version of RIP that will be used by IP. | 1.3.6.1.4.1.173.7.11.1 | INTEGER {ripVersion1(1), rip1Compatible(2), ripVersion2(3)} | read-write | mandatory |
| voice OBJECT-IDENTITY | 1.3.6.1.4.1.173.7.12 | |||
| voiceSystemVoiceNodeNum OBJECT-TYPE The number that identifies this node. | 1.3.6.1.4.1.173.7.12.1 | INTEGER (1..9999) | read-write | mandatory |
| voiceSystemRingVolFreq OBJECT-TYPE The frequency and voltage of the telephone ring circuit. In two wire OPX mode, the node provides ring voltage to the telephone when it is called by a remote unit. | 1.3.6.1.4.1.173.7.12.2 | INTEGER {v75-hz-16-66(1), v80-hz-20-00(2), v75-hz-25-00(3), v60-hz-50-00(4), v75-hz-50-00(5)} | read-write | mandatory |
| voiceSystemCountryCode OBJECT-TYPE The telephone dialing prefix code that identifies the country in which the node is installed. | 1.3.6.1.4.1.173.7.12.3 | INTEGER (1..999) | read-write | mandatory |
| voiceSystemDialDigits OBJECT-TYPE The number of digits that will be used in the speed dialing scheme, as well as the number of digits one can specify for the Auto Dial feature. This requires rebooting for the change to take effect. | 1.3.6.1.4.1.173.7.12.4 | INTEGER (2..4) | read-write | mandatory |
| voiceSystemVoiceRatesMin OBJECT-TYPE The minimum operating rate of all voice channels when congestion occurs. | 1.3.6.1.4.1.173.7.12.5 | INTEGER {bps-4800(1), bps-8000(2), bps-32000(3), bps-64000(4)} | read-write | mandatory |
| voiceSystemVoiceRatesMax OBJECT-TYPE The maximum operating digitization rate of all voice channels when there is no congestion. | 1.3.6.1.4.1.173.7.12.6 | INTEGER {bps-4800(1), bps-8000(2), bps-32000(3), bps-64000(4)} | read-write | mandatory |
| voiceSystemExtDialDigits OBJECT-TYPE The number of extended dial digits that can be defined in the speed map table and/or entered by the user of attached equipment as part of a dial string. This requires rebooting for the change to take effect. | 1.3.6.1.4.1.173.7.12.7 | INTEGER (0..16) | read-write | mandatory |
| voiceSpeedDialTable OBJECT-TYPE A list of speed-dial numbers. | 1.3.6.1.4.1.173.7.12.8 | not-accessible | mandatory | |
| voiceSpeedDialEntry OBJECT-TYPE A Voice Speed Dial entry containing objects relating to the speed-dial number that are configurable by the user. | 1.3.6.1.4.1.173.7.12.8.1 | not-accessible | mandatory | |
| voiceSpeedDialDigits OBJECT-TYPE The speed-dial number. A question mark wildcard can be used for any digit, and an asterisk wildcard can be used for any number of digits. | 1.3.6.1.4.1.173.7.12.8.1.1 | OCTET STRING (SIZE(1..4)) | read-only | mandatory |
| voiceSpeedDialLongDialMap OBJECT-TYPE The number for which the speed-dial number is a shortcut. | 1.3.6.1.4.1.173.7.12.8.1.2 | OCTET STRING (SIZE(6)) | read-write | mandatory |
| voiceSpeedDialExtDialStr OBJECT-TYPE The extended set of digits that will be forwarded with the call if portVoiceOperExtDigitsSource in the physical port record is set to Map. | 1.3.6.1.4.1.173.7.12.8.1.3 | OCTET STRING (SIZE(1..16)) | read-write | mandatory |
| voiceSpeedDialRowStatus OBJECT-TYPE This variable is used to manage the creation and deletion of conceptual rows in the voiceSpeedDialTable and follows the SNMPv2 RowStatus conventions by supporting the following values: - `active', which indicates that the conceptual row is available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row does not exist. - `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device. For a management protocol set operation, a genErr response is returned when the row already exists. - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row. Note that all of the above values may be specified in a management protocol set operation, and only the 'active' value will be returned in response to a management protocol retrieval operation. For a management protocol set operation, if other variable bindings are included in the same PDU, then a genErr response is returned. | 1.3.6.1.4.1.173.7.12.8.1.4 | RowStatus | read-write | mandatory |