MIBs Depot

NETI-PM-MIB

Registered at
1.3.6.1.4.1.2928.6.2.17
Last updated
2008-12-12 12:00
Organization
Net Insight AB
Revisions
2008-12-12 12:00
Namespace
netinsight
Source file
NETI-PM-MIB
Digest
sha256:b7414df2550f22c943c00c49cb8637b4819f2afafb1d8dbba101f3d09bb867e1

Description

The Net Insight PM (Performance Monitoring) MIB. The MIB implements objects for monitoring the performance of trunk interfaces, access interfaces and channels according to G.826.

Contact

Net Insight AB Box 42093 SE-126 14 Stockholm Sweden Tel +46-8-685 0400 info@netinsight.net

Imports

FromSymbols
NETI-COMMON-MIBnetiExperimentalGeneric
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter32, Gauge32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDateAndTime, DisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

NETI-COMMON-MIB
NETI-PM-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
Counter15m
TEXTUAL-CONVENTION
current
Counter24h
TEXTUAL-CONVENTION
current

Objects

NameOIDSyntaxAccessStatus
netiPMMIBObjects
OBJECT-IDENTITY
1.3.6.1.4.1.2928.6.2.17.1
pmTifGroup
OBJECT-IDENTITY
1.3.6.1.4.1.2928.6.2.17.1.1
pmTifTable
OBJECT-TYPE
Table of Performance Monitored trunk interfaces
1.3.6.1.4.1.2928.6.2.17.1.1.1not-accessiblecurrent
pmTifEntry
OBJECT-TYPE
One entry for each trunk interface
1.3.6.1.4.1.2928.6.2.17.1.1.1.1not-accessiblecurrent
pmTifIndex
OBJECT-TYPE
The index uniquely identifying this trunk interface.
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.1Unsigned32not-accessiblecurrent
pmTifAdminStatus
OBJECT-TYPE
The desired state of the PM function. Affects the operative state of the PM object
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.2INTEGER {up(1), down(2)}read-writecurrent
pmTifOperStatus
OBJECT-TYPE
PM operative state.
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.3INTEGER {up(1), down(2)}read-onlycurrent
pmTifFailure
OBJECT-TYPE
Shows current failure state. An empty string indicates no failure
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.4DisplayStringread-onlycurrent
pmTifDataSource
OBJECT-TYPE
The PM Data Source object
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.5OBJECT IDENTIFIERread-onlycurrent
pmTifDataSourceName
OBJECT-TYPE
The name of the PM Data Source
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.6DisplayStringread-onlycurrent
pmTifUatAlarmsEnabled
OBJECT-TYPE
If set to `true(1)' then UAT alarms will be sent. Unavailable time (UAT) defines a state where a service is unable to perform its normal task due to severe errors for a longer period. It begins at detection of ten consecutive SES events and ends at detection of ten consecutive non-SES events. In both cases, the 10s are considered part of unavailable respective available time and effects the visibility of G.826 PM events (they are delayed 10s) Entry and exit of UAT is declared by raising and clearing an UAT alarm (if enabled)
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.7TruthValueread-writecurrent
pmTifTresholdAlarmsEnabled
OBJECT-TYPE
If set to `true(1)' then threshold alarms will be sent. Each 15m and 24h current register counter can be assigned a threshold value. When crossed, a threshold crossing alarm will be sent for the interval if enabled. Raised alarm will be cleared at end of a following fault free interval i.e. one with all interval counter values below their threshold values and with no UAT. Only one TC alarm per interval can be raised, regardless of how many thresholds have been crossed.
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.8TruthValueread-writecurrent
pmTifPeriodicEventsEnabled
OBJECT-TYPE
If set to `true(1)' then History Periodic Events will be sent.
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.9TruthValueread-writecurrent
pmTifZeroSuppressionEnabled
OBJECT-TYPE
If set to `true(1)' then Zero Suppression mode is enabled Zero Suppression mode tells whether intervals with all current counters equal to zero shall be stored in the history log or not. If enabled, once a faulty interval is found, its current register content including a zero suppressed interval counter will be stored in the history log. The additional counter specifies how many fault free intervals have preceded the faulty one. In such way, history for a larger measurement period can be logged than would otherwise be possible
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.10TruthValueread-writecurrent
pmTifHistorySize
OBJECT-TYPE
The size of the history log
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.11INTEGER {none(1), small(2), large(3)}read-writecurrent
pmTif15mTresholdES
OBJECT-TYPE
15 minute threshold value for ES. Current ES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.12Counter15mread-writecurrent
pmTif15mTresholdSES
OBJECT-TYPE
15 minute threshold value for SES. Current SES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.13Counter15mread-writecurrent
pmTif15mTresholdBBE
OBJECT-TYPE
15 minute threshold value for BBE. Current BBE value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.14Gauge32read-writecurrent
pmTif15mTresholdSS
OBJECT-TYPE
15 minute threshold value for SS. Current SS value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.15Counter15mread-writecurrent
pmTif24hTresholdES
OBJECT-TYPE
24 hour threshold value for ES. Current ES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.16Counter24hread-writecurrent
pmTif24hTresholdSES
OBJECT-TYPE
24 hour threshold value for SES. Current SES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.17Counter24hread-writecurrent
pmTif24hTresholdBBE
OBJECT-TYPE
24 hour threshold value for BBE. Current BBE value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.18Gauge32read-writecurrent
pmTif24hTresholdSS
OBJECT-TYPE
24 hour threshold value for SS. Current SS value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.1.1.1.19Counter24hread-writecurrent
pmTifCurrentTable
OBJECT-TYPE
Table of PM data for the current 15 minute period
1.3.6.1.4.1.2928.6.2.17.1.1.2not-accessiblecurrent
pmTifCurrentEntry
OBJECT-TYPE
One entry for each monitored object
1.3.6.1.4.1.2928.6.2.17.1.1.2.1not-accessiblecurrent
pmTifCurrentTime
OBJECT-TYPE
Elapsed time in seconds for the current 15 minute period.
1.3.6.1.4.1.2928.6.2.17.1.1.2.1.2Counter15mread-onlycurrent
pmTifCurrentSuspect
OBJECT-TYPE
Is Suspect flag, if set to `true(1)' the current 15 minute measurement period has unreliable measurement data.
1.3.6.1.4.1.2928.6.2.17.1.1.2.1.3TruthValueread-onlycurrent
pmTifCurrentZS
OBJECT-TYPE
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
1.3.6.1.4.1.2928.6.2.17.1.1.2.1.4Counter32read-onlycurrent
pmTifCurrentESs
OBJECT-TYPE
Number of Errored Seconds (ES) for the current 15 minute period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
1.3.6.1.4.1.2928.6.2.17.1.1.2.1.5Counter15mread-onlycurrent
pmTifCurrentSESs
OBJECT-TYPE
Number of Severe Errored Seconds (SES) for the current 15 minute period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
1.3.6.1.4.1.2928.6.2.17.1.1.2.1.6Counter15mread-onlycurrent
pmTifCurrentBBEs
OBJECT-TYPE
Number of Background Block Error (BBE) for the current 15 minute period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
1.3.6.1.4.1.2928.6.2.17.1.1.2.1.7Gauge32read-onlycurrent
pmTifCurrentUASs
OBJECT-TYPE
Number of Unavailable Second (UAS) for the current 15 minute period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
1.3.6.1.4.1.2928.6.2.17.1.1.2.1.8Counter15mread-onlycurrent
pmTifCurrentSSs
OBJECT-TYPE
Number of SLIP Second (SS) for the current 15 minute period. SS is defined as one second containing one or more SLIPs
1.3.6.1.4.1.2928.6.2.17.1.1.2.1.9Counter15mread-onlycurrent
pmTif15mTable
OBJECT-TYPE
Table of 15 minute PM log history
1.3.6.1.4.1.2928.6.2.17.1.1.3not-accessiblecurrent
pmTif15mEntry
OBJECT-TYPE
One entry for each 15 minute PM interval
1.3.6.1.4.1.2928.6.2.17.1.1.3.1not-accessiblecurrent
pmTif15mIndex
OBJECT-TYPE
The index that identifies the interval for which the set of statistics is available. Index of '0' indicates the most recently completed interval, and the index is increased by one for each interval back in time.
1.3.6.1.4.1.2928.6.2.17.1.1.3.1.1Unsigned32not-accessiblecurrent
pmTif15mTime
OBJECT-TYPE
Time stamp for this 15 minute interval
1.3.6.1.4.1.2928.6.2.17.1.1.3.1.2DateAndTimeread-onlycurrent
pmTif15mSuspect
OBJECT-TYPE
Suspect flag for this 15 minute interval
1.3.6.1.4.1.2928.6.2.17.1.1.3.1.3TruthValueread-onlycurrent
pmTif15mZS
OBJECT-TYPE
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
1.3.6.1.4.1.2928.6.2.17.1.1.3.1.4Counter32read-onlycurrent
pmTif15mESs
OBJECT-TYPE
Number of Errored Seconds (ES) for this 15 minute period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
1.3.6.1.4.1.2928.6.2.17.1.1.3.1.5Counter15mread-onlycurrent
pmTif15mSESs
OBJECT-TYPE
Number of Severe Errored Seconds (SES) for this 15 minute period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
1.3.6.1.4.1.2928.6.2.17.1.1.3.1.6Counter15mread-onlycurrent
pmTif15mBBEs
OBJECT-TYPE
Number of Background Block Error (BBE) for this 15 minute period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
1.3.6.1.4.1.2928.6.2.17.1.1.3.1.7Gauge32read-onlycurrent
pmTif15mUASs
OBJECT-TYPE
Number of Unavailable Second (UAS) for this 15 minute period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
1.3.6.1.4.1.2928.6.2.17.1.1.3.1.8Counter15mread-onlycurrent
pmTif15mSSs
OBJECT-TYPE
Number of SLIP Second (SS) for this 15 minute period. SS is defined as one second containing one or more SLIPs
1.3.6.1.4.1.2928.6.2.17.1.1.3.1.9Counter15mread-onlycurrent
pmTif24hTable
OBJECT-TYPE
Table of 24 hour PM log history
1.3.6.1.4.1.2928.6.2.17.1.1.4not-accessiblecurrent
pmTif24hEntry
OBJECT-TYPE
One entry for each 24 hour PM interval
1.3.6.1.4.1.2928.6.2.17.1.1.4.1not-accessiblecurrent
pmTif24hIndex
OBJECT-TYPE
The index that identifies the interval for which the set of statistics is available. Index of '0' indicates the most recently completed interval, and the index is increased by one for each interval back in time.
1.3.6.1.4.1.2928.6.2.17.1.1.4.1.1Unsigned32not-accessiblecurrent
pmTif24hTime
OBJECT-TYPE
Time stamp for this 24 hour interval
1.3.6.1.4.1.2928.6.2.17.1.1.4.1.2DateAndTimeread-onlycurrent
pmTif24hSuspect
OBJECT-TYPE
Suspect flag for this 24 hour interval
1.3.6.1.4.1.2928.6.2.17.1.1.4.1.3TruthValueread-onlycurrent
pmTif24hZS
OBJECT-TYPE
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
1.3.6.1.4.1.2928.6.2.17.1.1.4.1.4Counter32read-onlycurrent
pmTif24hESs
OBJECT-TYPE
Number of Errored Seconds (ES) for this 24 hour period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
1.3.6.1.4.1.2928.6.2.17.1.1.4.1.5Counter24hread-onlycurrent
pmTif24hSESs
OBJECT-TYPE
Number of Severe Errored Seconds (SES) for this 24 hour period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
1.3.6.1.4.1.2928.6.2.17.1.1.4.1.6Counter24hread-onlycurrent
pmTif24hBBEs
OBJECT-TYPE
Number of Background Block Error (BBE) for this 24 hour period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
1.3.6.1.4.1.2928.6.2.17.1.1.4.1.7Gauge32read-onlycurrent
pmTif24hUASs
OBJECT-TYPE
Number of Unavailable Second (UAS) for this 24 hour period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
1.3.6.1.4.1.2928.6.2.17.1.1.4.1.8Counter24hread-onlycurrent
pmTif24hSSs
OBJECT-TYPE
Number of SLIP Second (SS) for this 24 hour period. SS is defined as one second containing one or more SLIPs
1.3.6.1.4.1.2928.6.2.17.1.1.4.1.9Counter24hread-onlycurrent
pmTif24hCurrentTable
OBJECT-TYPE
Table of PM data for the current 24 hour period
1.3.6.1.4.1.2928.6.2.17.1.1.5not-accessiblecurrent
pmTif24hCurrentEntry
OBJECT-TYPE
One entry for each monitored object
1.3.6.1.4.1.2928.6.2.17.1.1.5.1not-accessiblecurrent
pmTif24hCurrentTime
OBJECT-TYPE
Elapsed time in seconds for the current 24 hour period.
1.3.6.1.4.1.2928.6.2.17.1.1.5.1.2Counter15mread-onlycurrent
pmTif24hCurrentSuspect
OBJECT-TYPE
Is Suspect flag, if set to `true(1)' the current 24 hour measurement period has unreliable measurement data.
1.3.6.1.4.1.2928.6.2.17.1.1.5.1.3TruthValueread-onlycurrent
pmTif24hCurrentZS
OBJECT-TYPE
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
1.3.6.1.4.1.2928.6.2.17.1.1.5.1.4Counter32read-onlycurrent
pmTif24hCurrentESs
OBJECT-TYPE
Number of Errored Seconds (ES) for the current 24 hour period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
1.3.6.1.4.1.2928.6.2.17.1.1.5.1.5Counter15mread-onlycurrent
pmTif24hCurrentSESs
OBJECT-TYPE
Number of Severe Errored Seconds (SES) for the current 24 hour period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
1.3.6.1.4.1.2928.6.2.17.1.1.5.1.6Counter15mread-onlycurrent
pmTif24hCurrentBBEs
OBJECT-TYPE
Number of Background Block Error (BBE) for the current 24 hour period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
1.3.6.1.4.1.2928.6.2.17.1.1.5.1.7Gauge32read-onlycurrent
pmTif24hCurrentUASs
OBJECT-TYPE
Number of Unavailable Second (UAS) for the current 24 hour period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
1.3.6.1.4.1.2928.6.2.17.1.1.5.1.8Counter15mread-onlycurrent
pmTif24hCurrentSSs
OBJECT-TYPE
Number of SLIP Second (SS) for the current 24 hour period. SS is defined as one second containing one or more SLIPs
1.3.6.1.4.1.2928.6.2.17.1.1.5.1.9Counter15mread-onlycurrent
pmAifGroup
OBJECT-IDENTITY
1.3.6.1.4.1.2928.6.2.17.1.2
pmAifTable
OBJECT-TYPE
Table of Performance Monitored access interfaces
1.3.6.1.4.1.2928.6.2.17.1.2.1not-accessiblecurrent
pmAifEntry
OBJECT-TYPE
One entry for each access interface
1.3.6.1.4.1.2928.6.2.17.1.2.1.1not-accessiblecurrent
pmAifIndex
OBJECT-TYPE
The index uniquely identifying this access interface.
1.3.6.1.4.1.2928.6.2.17.1.2.1.1.1Unsigned32not-accessiblecurrent
pmAifAdminStatus
OBJECT-TYPE
The desired state of the PM function. Affects the operative state of the PM object
1.3.6.1.4.1.2928.6.2.17.1.2.1.1.2INTEGER {up(1), down(2)}read-writecurrent
pmAifOperStatus
OBJECT-TYPE
PM operative state.
1.3.6.1.4.1.2928.6.2.17.1.2.1.1.3INTEGER {up(1), down(2)}read-onlycurrent
pmAifFailure
OBJECT-TYPE
Shows current failure state. An empty string indicates no failure
1.3.6.1.4.1.2928.6.2.17.1.2.1.1.4DisplayStringread-onlycurrent
pmAifDataSource
OBJECT-TYPE
The PM Data Source object
1.3.6.1.4.1.2928.6.2.17.1.2.1.1.5OBJECT IDENTIFIERread-onlycurrent
pmAifDataSourceName
OBJECT-TYPE
The name of the PM Data Source
1.3.6.1.4.1.2928.6.2.17.1.2.1.1.6DisplayStringread-onlycurrent
pmAifUatAlarmsEnabled
OBJECT-TYPE
If set to `true(1)' then UAT alarms will be sent. Unavailable time (UAT) defines a state where a service is unable to perform its normal task due to severe errors for a longer period. It begins at detection of ten consecutive SES events and ends at detection of ten consecutive non-SES events. In both cases, the 10s are considered part of unavailable respective available time and effects the visibility of G.826 PM events (they are delayed 10s) Entry and exit of UAT is declared by raising and clearing an UAT alarm (if enabled)
1.3.6.1.4.1.2928.6.2.17.1.2.1.1.7TruthValueread-writecurrent
pmAifTresholdAlarmsEnabled
OBJECT-TYPE
If set to `true(1)' then threshold alarms will be sent. Each 15m and 24h current register counter can be assigned a threshold value. When crossed, a threshold crossing alarm will be sent for the interval if enabled. Raised alarm will be cleared at end of a following fault free interval i.e. one with all interval counter values below their threshold values and with no UAT. Only one TC alarm per interval can be raised, regardless of how many thresholds have been crossed.
1.3.6.1.4.1.2928.6.2.17.1.2.1.1.8TruthValueread-writecurrent
pmAifPeriodicEventsEnabled
OBJECT-TYPE
If set to `true(1)' then History Periodic Events will be sent.
1.3.6.1.4.1.2928.6.2.17.1.2.1.1.9TruthValueread-writecurrent
pmAifZeroSuppressionEnabled
OBJECT-TYPE
If set to `true(1)' then Zero Suppression mode is enabled Zero Suppression mode tells whether intervals with all current counters equal to zero shall be stored in the history log or not. If enabled, once a faulty interval is found, its current register content including a zero suppressed interval counter will be stored in the history log. The additional counter specifies how many fault free intervals have preceded the faulty one. In such way, history for a larger measurement period can be logged than would otherwise be possible
1.3.6.1.4.1.2928.6.2.17.1.2.1.1.10TruthValueread-writecurrent
pmAifHistorySize
OBJECT-TYPE
The size of the history log
1.3.6.1.4.1.2928.6.2.17.1.2.1.1.11INTEGER {none(1), small(2), large(3)}read-writecurrent
pmAif15mTresholdES
OBJECT-TYPE
15 minute threshold value for ES. Current ES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.2.1.1.12Counter15mread-writecurrent
pmAif15mTresholdSES
OBJECT-TYPE
15 minute threshold value for SES. Current SES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.2.1.1.13Counter15mread-writecurrent
pmAif15mTresholdBBE
OBJECT-TYPE
15 minute threshold value for BBE. Current BBE value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.2.1.1.14Gauge32read-writecurrent
pmAif24hTresholdES
OBJECT-TYPE
24 hour threshold value for ES. Current ES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.2.1.1.15Counter24hread-writecurrent
pmAif24hTresholdSES
OBJECT-TYPE
24 hour threshold value for SES. Current SES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.2.1.1.16Counter24hread-writecurrent
pmAif24hTresholdBBE
OBJECT-TYPE
24 hour threshold value for BBE. Current BBE value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.2.1.1.17Gauge32read-writecurrent
pmAifCurrentTable
OBJECT-TYPE
Table of PM data for the current 15 minute period
1.3.6.1.4.1.2928.6.2.17.1.2.2not-accessiblecurrent
pmAifCurrentEntry
OBJECT-TYPE
One entry for each monitored object
1.3.6.1.4.1.2928.6.2.17.1.2.2.1not-accessiblecurrent
pmAifCurrentTime
OBJECT-TYPE
Elapsed time in seconds for the current 15 minute period.
1.3.6.1.4.1.2928.6.2.17.1.2.2.1.2Counter15mread-onlycurrent
pmAifCurrentSuspect
OBJECT-TYPE
Is Suspect flag, if set to `true(1)' the current 15 minute measurement period has unreliable measurement data.
1.3.6.1.4.1.2928.6.2.17.1.2.2.1.3TruthValueread-onlycurrent
pmAifCurrentZS
OBJECT-TYPE
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
1.3.6.1.4.1.2928.6.2.17.1.2.2.1.4Counter32read-onlycurrent
pmAifCurrentESs
OBJECT-TYPE
Number of Errored Seconds (ES) for the current 15 minute period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
1.3.6.1.4.1.2928.6.2.17.1.2.2.1.5Counter15mread-onlycurrent
pmAifCurrentSESs
OBJECT-TYPE
Number of Severe Errored Seconds (SES) for the current 15 minute period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
1.3.6.1.4.1.2928.6.2.17.1.2.2.1.6Counter15mread-onlycurrent
pmAifCurrentBBEs
OBJECT-TYPE
Number of Background Block Error (BBE) for the current 15 minute period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
1.3.6.1.4.1.2928.6.2.17.1.2.2.1.7Gauge32read-onlycurrent
pmAifCurrentUASs
OBJECT-TYPE
Number of Unavailable Second (UAS) for the current 15 minute period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
1.3.6.1.4.1.2928.6.2.17.1.2.2.1.8Counter15mread-onlycurrent
pmAif15mTable
OBJECT-TYPE
Table of 15 minute PM interval history
1.3.6.1.4.1.2928.6.2.17.1.2.3not-accessiblecurrent
pmAif15mEntry
OBJECT-TYPE
One entry for each 15 minute PM interval
1.3.6.1.4.1.2928.6.2.17.1.2.3.1not-accessiblecurrent
pmAif15mIndex
OBJECT-TYPE
The index that identifies the interval for which the set of statistics is available. Index of '0' indicates the most recently completed interval, and the index is increased by one for each interval back in time.
1.3.6.1.4.1.2928.6.2.17.1.2.3.1.1Unsigned32not-accessiblecurrent
pmAif15mTime
OBJECT-TYPE
Time stamp for this 15 minute interval
1.3.6.1.4.1.2928.6.2.17.1.2.3.1.2DateAndTimeread-onlycurrent
pmAif15mSuspect
OBJECT-TYPE
Suspect flag for this 15 minute interval
1.3.6.1.4.1.2928.6.2.17.1.2.3.1.3TruthValueread-onlycurrent
pmAif15mZS
OBJECT-TYPE
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
1.3.6.1.4.1.2928.6.2.17.1.2.3.1.4Counter32read-onlycurrent
pmAif15mESs
OBJECT-TYPE
Number of Errored Seconds (ES) for this 15 minute period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
1.3.6.1.4.1.2928.6.2.17.1.2.3.1.5Counter15mread-onlycurrent
pmAif15mSESs
OBJECT-TYPE
Number of Severe Errored Seconds (SES) for this 15 minute period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
1.3.6.1.4.1.2928.6.2.17.1.2.3.1.6Counter15mread-onlycurrent
pmAif15mBBEs
OBJECT-TYPE
Number of Background Block Error (BBE) for this 15 minute period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
1.3.6.1.4.1.2928.6.2.17.1.2.3.1.7Gauge32read-onlycurrent
pmAif15mUASs
OBJECT-TYPE
Number of Unavailable Second (UAS) for this 15 minute period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
1.3.6.1.4.1.2928.6.2.17.1.2.3.1.8Counter15mread-onlycurrent
pmAif24hTable
OBJECT-TYPE
Table of 24 hour PM log history
1.3.6.1.4.1.2928.6.2.17.1.2.4not-accessiblecurrent
pmAif24hEntry
OBJECT-TYPE
One entry for each 24 hour PM interval
1.3.6.1.4.1.2928.6.2.17.1.2.4.1not-accessiblecurrent
pmAif24hIndex
OBJECT-TYPE
The index that identifies the interval for which the set of statistics is available. Index of '0' indicates the most recently completed interval, and the index is increased by one for each interval back in time.
1.3.6.1.4.1.2928.6.2.17.1.2.4.1.1Unsigned32not-accessiblecurrent
pmAif24hTime
OBJECT-TYPE
Time stamp for this 24 hour interval
1.3.6.1.4.1.2928.6.2.17.1.2.4.1.2DateAndTimeread-onlycurrent
pmAif24hSuspect
OBJECT-TYPE
Suspect flag for this 24 hour interval
1.3.6.1.4.1.2928.6.2.17.1.2.4.1.3TruthValueread-onlycurrent
pmAif24hZS
OBJECT-TYPE
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
1.3.6.1.4.1.2928.6.2.17.1.2.4.1.4Counter32read-onlycurrent
pmAif24hESs
OBJECT-TYPE
Number of Errored Seconds (ES) for this 24 hour period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
1.3.6.1.4.1.2928.6.2.17.1.2.4.1.5Counter24hread-onlycurrent
pmAif24hSESs
OBJECT-TYPE
Number of Severe Errored Seconds (SES) for this 24 hour period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
1.3.6.1.4.1.2928.6.2.17.1.2.4.1.6Counter24hread-onlycurrent
pmAif24hBBEs
OBJECT-TYPE
Number of Background Block Error (BBE) for this 24 hour period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
1.3.6.1.4.1.2928.6.2.17.1.2.4.1.7Gauge32read-onlycurrent
pmAif24hUASs
OBJECT-TYPE
Number of Unavailable Second (UAS) for this 24 hour period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
1.3.6.1.4.1.2928.6.2.17.1.2.4.1.8Counter24hread-onlycurrent
pmAif24hCurrentTable
OBJECT-TYPE
Table of PM data for the current 24 hour period
1.3.6.1.4.1.2928.6.2.17.1.2.5not-accessiblecurrent
pmAif24hCurrentEntry
OBJECT-TYPE
One entry for each monitored object
1.3.6.1.4.1.2928.6.2.17.1.2.5.1not-accessiblecurrent
pmAif24hCurrentTime
OBJECT-TYPE
Elapsed time in seconds for the current 24 hour period.
1.3.6.1.4.1.2928.6.2.17.1.2.5.1.2Counter15mread-onlycurrent
pmAif24hCurrentSuspect
OBJECT-TYPE
Is Suspect flag, if set to `true(1)' the current 24 hour measurement period has unreliable measurement data.
1.3.6.1.4.1.2928.6.2.17.1.2.5.1.3TruthValueread-onlycurrent
pmAif24hCurrentZS
OBJECT-TYPE
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
1.3.6.1.4.1.2928.6.2.17.1.2.5.1.4Counter32read-onlycurrent
pmAif24hCurrentESs
OBJECT-TYPE
Number of Errored Seconds (ES) for the current 24 hour period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
1.3.6.1.4.1.2928.6.2.17.1.2.5.1.5Counter15mread-onlycurrent
pmAif24hCurrentSESs
OBJECT-TYPE
Number of Severe Errored Seconds (SES) for the current 24 hour period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
1.3.6.1.4.1.2928.6.2.17.1.2.5.1.6Counter15mread-onlycurrent
pmAif24hCurrentBBEs
OBJECT-TYPE
Number of Background Block Error (BBE) for the current 24 hour period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
1.3.6.1.4.1.2928.6.2.17.1.2.5.1.7Gauge32read-onlycurrent
pmAif24hCurrentUASs
OBJECT-TYPE
Number of Unavailable Second (UAS) for the current 24 hour period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
1.3.6.1.4.1.2928.6.2.17.1.2.5.1.8Counter15mread-onlycurrent
pmDchGroup
OBJECT-IDENTITY
1.3.6.1.4.1.2928.6.2.17.1.3
pmDchTable
OBJECT-TYPE
Table of Performance Monitored DTM channel
1.3.6.1.4.1.2928.6.2.17.1.3.1not-accessiblecurrent
pmDchEntry
OBJECT-TYPE
One entry for each DTM channel
1.3.6.1.4.1.2928.6.2.17.1.3.1.1not-accessiblecurrent
pmDchIndex
OBJECT-TYPE
The index uniquely identifying this DTM channel.
1.3.6.1.4.1.2928.6.2.17.1.3.1.1.1Unsigned32not-accessiblecurrent
pmDchAdminStatus
OBJECT-TYPE
The desired state of the PM function. Affects the operative state of the PM object
1.3.6.1.4.1.2928.6.2.17.1.3.1.1.2INTEGER {up(1), down(2)}read-writecurrent
pmDchOperStatus
OBJECT-TYPE
PM operative state.
1.3.6.1.4.1.2928.6.2.17.1.3.1.1.3INTEGER {up(1), down(2)}read-onlycurrent
pmDchFailure
OBJECT-TYPE
Shows current failure state. An empty string indicates no failure
1.3.6.1.4.1.2928.6.2.17.1.3.1.1.4DisplayStringread-onlycurrent
pmDchDataSource
OBJECT-TYPE
The PM Data Source object
1.3.6.1.4.1.2928.6.2.17.1.3.1.1.5OBJECT IDENTIFIERread-onlycurrent
pmDchDataSourceName
OBJECT-TYPE
The name of the PM Data Source
1.3.6.1.4.1.2928.6.2.17.1.3.1.1.6DisplayStringread-onlycurrent
pmDchUatAlarmsEnabled
OBJECT-TYPE
If set to `true(1)' then UAT alarms will be sent. Unavailable time (UAT) defines a state where a service is unable to perform its normal task due to severe errors for a longer period. It begins at detection of ten consecutive SES events and ends at detection of ten consecutive non-SES events. In both cases, the 10s are considered part of unavailable respective available time and effects the visibility of G.826 PM events (they are delayed 10s) Entry and exit of UAT is declared by raising and clearing an UAT alarm (if enabled)
1.3.6.1.4.1.2928.6.2.17.1.3.1.1.7TruthValueread-writecurrent
pmDchTresholdAlarmsEnabled
OBJECT-TYPE
If set to `true(1)' then threshold alarms will be sent. Each 15m and 24h current register counter can be assigned a threshold value. When crossed, a threshold crossing alarm will be sent for the interval if enabled. Raised alarm will be cleared at end of a following fault free interval i.e. one with all interval counter values below their threshold values and with no UAT. Only one TC alarm per interval can be raised, regardless of how many thresholds have been crossed.
1.3.6.1.4.1.2928.6.2.17.1.3.1.1.8TruthValueread-writecurrent
pmDchPeriodicEventsEnabled
OBJECT-TYPE
If set to `true(1)' then History Periodic Events will be sent.
1.3.6.1.4.1.2928.6.2.17.1.3.1.1.9TruthValueread-writecurrent
pmDchZeroSuppressionEnabled
OBJECT-TYPE
If set to `true(1)' then Zero Suppression mode is enabled Zero Suppression mode tells whether intervals with all current counters equal to zero shall be stored in the history log or not. If enabled, once a faulty interval is found, its current register content including a zero suppressed interval counter will be stored in the history log. The additional counter specifies how many fault free intervals have preceded the faulty one. In such way, history for a larger measurement period can be logged than would otherwise be possible
1.3.6.1.4.1.2928.6.2.17.1.3.1.1.10TruthValueread-writecurrent
pmDchHistorySize
OBJECT-TYPE
The size of the history log
1.3.6.1.4.1.2928.6.2.17.1.3.1.1.11INTEGER {none(1), small(2), large(3)}read-writecurrent
pmDch15mTresholdES
OBJECT-TYPE
15 minute threshold value for ES. Current ES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.3.1.1.12Counter15mread-writecurrent
pmDch15mTresholdSES
OBJECT-TYPE
15 minute threshold value for SES. Current SES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.3.1.1.13Counter15mread-writecurrent
pmDch15mTresholdBBE
OBJECT-TYPE
15 minute threshold value for BBE. Current BBE value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.3.1.1.14Gauge32read-writecurrent
pmDch24hTresholdES
OBJECT-TYPE
24 hour threshold value for ES. Current ES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.3.1.1.15Counter24hread-writecurrent
pmDch24hTresholdSES
OBJECT-TYPE
24 hour threshold value for SES. Current SES value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.3.1.1.16Counter24hread-writecurrent
pmDch24hTresholdBBE
OBJECT-TYPE
24 hour threshold value for BBE. Current BBE value equal to or above this threshold will raise a threshold alarm if enabled. A value of zero will disable threshold check.
1.3.6.1.4.1.2928.6.2.17.1.3.1.1.17Gauge32read-writecurrent
pmDchCurrentTable
OBJECT-TYPE
Table of PM data for the current 15 minute period
1.3.6.1.4.1.2928.6.2.17.1.3.2not-accessiblecurrent
pmDchCurrentEntry
OBJECT-TYPE
One entry for each monitored object
1.3.6.1.4.1.2928.6.2.17.1.3.2.1not-accessiblecurrent
pmDchCurrentTime
OBJECT-TYPE
Elapsed time in seconds for the current 15 minute period.
1.3.6.1.4.1.2928.6.2.17.1.3.2.1.2Counter15mread-onlycurrent
pmDchCurrentSuspect
OBJECT-TYPE
Is Suspect flag, if set to `true(1)' the current 15 minute measurement period has unreliable measurement data.
1.3.6.1.4.1.2928.6.2.17.1.3.2.1.3TruthValueread-onlycurrent
pmDchCurrentZS
OBJECT-TYPE
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
1.3.6.1.4.1.2928.6.2.17.1.3.2.1.4Counter32read-onlycurrent
pmDchCurrentESs
OBJECT-TYPE
Number of Errored Seconds (ES) for the current 15 minute period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
1.3.6.1.4.1.2928.6.2.17.1.3.2.1.5Counter15mread-onlycurrent
pmDchCurrentSESs
OBJECT-TYPE
Number of Severe Errored Seconds (SES) for the current 15 minute period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
1.3.6.1.4.1.2928.6.2.17.1.3.2.1.6Counter15mread-onlycurrent
pmDchCurrentBBEs
OBJECT-TYPE
Number of Background Block Error (BBE) for the current 15 minute period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
1.3.6.1.4.1.2928.6.2.17.1.3.2.1.7Gauge32read-onlycurrent
pmDchCurrentUASs
OBJECT-TYPE
Number of Unavailable Second (UAS) for the current 15 minute period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
1.3.6.1.4.1.2928.6.2.17.1.3.2.1.8Counter15mread-onlycurrent
pmDch15mTable
OBJECT-TYPE
Table of 15 minute PM interval history
1.3.6.1.4.1.2928.6.2.17.1.3.3not-accessiblecurrent
pmDch15mEntry
OBJECT-TYPE
One entry for each 15 minute PM interval
1.3.6.1.4.1.2928.6.2.17.1.3.3.1not-accessiblecurrent
pmDch15mIndex
OBJECT-TYPE
The index that identifies the interval for which the set of statistics is available. Index of '0' indicates the most recently completed interval, and the index is increased by one for each interval back in time.
1.3.6.1.4.1.2928.6.2.17.1.3.3.1.1Unsigned32not-accessiblecurrent
pmDch15mTime
OBJECT-TYPE
Time stamp for this 15 minute interval
1.3.6.1.4.1.2928.6.2.17.1.3.3.1.2DateAndTimeread-onlycurrent
pmDch15mSuspect
OBJECT-TYPE
Suspect flag for this 15 minute interval
1.3.6.1.4.1.2928.6.2.17.1.3.3.1.3TruthValueread-onlycurrent
pmDch15mZS
OBJECT-TYPE
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
1.3.6.1.4.1.2928.6.2.17.1.3.3.1.4Counter32read-onlycurrent
pmDch15mESs
OBJECT-TYPE
Number of Errored Seconds (ES) for this 15 minute period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
1.3.6.1.4.1.2928.6.2.17.1.3.3.1.5Counter15mread-onlycurrent
pmDch15mSESs
OBJECT-TYPE
Number of Severe Errored Seconds (SES) for this 15 minute period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
1.3.6.1.4.1.2928.6.2.17.1.3.3.1.6Counter15mread-onlycurrent
pmDch15mBBEs
OBJECT-TYPE
Number of Background Block Error (BBE) for this 15 minute period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
1.3.6.1.4.1.2928.6.2.17.1.3.3.1.7Gauge32read-onlycurrent
pmDch15mUASs
OBJECT-TYPE
Number of Unavailable Second (UAS) for this 15 minute period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
1.3.6.1.4.1.2928.6.2.17.1.3.3.1.8Counter15mread-onlycurrent
pmDch24hTable
OBJECT-TYPE
Table of 24 hour PM interval history
1.3.6.1.4.1.2928.6.2.17.1.3.4not-accessiblecurrent
pmDch24hEntry
OBJECT-TYPE
One entry for each 24 hour PM interval
1.3.6.1.4.1.2928.6.2.17.1.3.4.1not-accessiblecurrent
pmDch24hIndex
OBJECT-TYPE
The index that identifies the interval for which the set of statistics is available. Index of '0' indicates the most recently completed interval, and the index is increased by one for each interval back in time.
1.3.6.1.4.1.2928.6.2.17.1.3.4.1.1Unsigned32not-accessiblecurrent
pmDch24hTime
OBJECT-TYPE
Time stamp for this 24 hour interval
1.3.6.1.4.1.2928.6.2.17.1.3.4.1.2DateAndTimeread-onlycurrent
pmDch24hSuspect
OBJECT-TYPE
Suspect flag for this 24 hour interval
1.3.6.1.4.1.2928.6.2.17.1.3.4.1.3TruthValueread-onlycurrent
pmDch24hZS
OBJECT-TYPE
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
1.3.6.1.4.1.2928.6.2.17.1.3.4.1.4Counter32read-onlycurrent
pmDch24hESs
OBJECT-TYPE
Number of Errored Seconds (ES) for this 24 hour period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
1.3.6.1.4.1.2928.6.2.17.1.3.4.1.5Counter24hread-onlycurrent
pmDch24hSESs
OBJECT-TYPE
Number of Severe Errored Seconds (SES) for this 24 hour period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
1.3.6.1.4.1.2928.6.2.17.1.3.4.1.6Counter24hread-onlycurrent
pmDch24hBBEs
OBJECT-TYPE
Number of Background Block Error (BBE) for this 24 hour period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
1.3.6.1.4.1.2928.6.2.17.1.3.4.1.7Gauge32read-onlycurrent
pmDch24hUASs
OBJECT-TYPE
Number of Unavailable Second (UAS) for this 24 hour period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
1.3.6.1.4.1.2928.6.2.17.1.3.4.1.8Counter24hread-onlycurrent
pmDch24hCurrentTable
OBJECT-TYPE
Table of PM data for the current 24 hour period
1.3.6.1.4.1.2928.6.2.17.1.3.5not-accessiblecurrent
pmDch24hCurrentEntry
OBJECT-TYPE
One entry for each monitored object
1.3.6.1.4.1.2928.6.2.17.1.3.5.1not-accessiblecurrent
pmDch24hCurrentTime
OBJECT-TYPE
Elapsed time in seconds for the current 24 hour period.
1.3.6.1.4.1.2928.6.2.17.1.3.5.1.2Counter15mread-onlycurrent
pmDch24hCurrentSuspect
OBJECT-TYPE
Is Suspect flag, if set to `true(1)' the current 24 hour measurement period has unreliable measurement data.
1.3.6.1.4.1.2928.6.2.17.1.3.5.1.3TruthValueread-onlycurrent
pmDch24hCurrentZS
OBJECT-TYPE
Zero Suppression Counter. If the performance monitoring uses zero suppression, this counter specifies how many fault free intervals have preceded the faulty one.
1.3.6.1.4.1.2928.6.2.17.1.3.5.1.4Counter32read-onlycurrent
pmDch24hCurrentESs
OBJECT-TYPE
Number of Errored Seconds (ES) for the current 24 hour period. ES is defined as one second of available time containing one or more Errored Blocks (EB) or at least one defect
1.3.6.1.4.1.2928.6.2.17.1.3.5.1.5Counter15mread-onlycurrent
pmDch24hCurrentSESs
OBJECT-TYPE
Number of Severe Errored Seconds (SES) for the current 24 hour period. SES is defined as one second of available time containing more than 30% Errored Blocks (EB) or at least one defect.
1.3.6.1.4.1.2928.6.2.17.1.3.5.1.6Counter15mread-onlycurrent
pmDch24hCurrentBBEs
OBJECT-TYPE
Number of Background Block Error (BBE) for the current 24 hour period. BBE is defined as the number of Errored Blocks (EB) during one second of available time not part of SES
1.3.6.1.4.1.2928.6.2.17.1.3.5.1.7Gauge32read-onlycurrent
pmDch24hCurrentUASs
OBJECT-TYPE
Number of Unavailable Second (UAS) for the current 24 hour period. UAS is defined as one second of UAT (Unavailable Time). During UAT calculations of BBE, ES and SES are inhibited and no data collection of them is performed
1.3.6.1.4.1.2928.6.2.17.1.3.5.1.8Counter15mread-onlycurrent
pmConformanceGroups
OBJECT-IDENTITY
1.3.6.1.4.1.2928.6.2.17.1.4

Conformance

NameOIDStatus
pmTifConformanceGroup
OBJECT-GROUP
The PM Trunk Interface Conformance Group.
1.3.6.1.4.1.2928.6.2.17.1.4.1current
pmAifConformanceGroup
OBJECT-GROUP
The PM Access Interface Conformance Group.
1.3.6.1.4.1.2928.6.2.17.1.4.2current
pmDchConformanceGroup
OBJECT-GROUP
The PM Channel Conformance Group.
1.3.6.1.4.1.2928.6.2.17.1.4.3current