MIBs Depot

NBS-SFF-MIB

Registered at
1.3.6.1.4.1.629.204
Last updated
2017-06-06 00:00
Organization
NBS
Namespace
mrv
Source file
NBS-SFF-MIB
Digest
sha256:62d3f635f2da68ccd6af3908b824afcbfaa216648a37cf30b259707601228fa7

Description

MIB for representing SFF MSA standards

Contact

For technical support, please contact your service channel

Imports

FromSymbols
IF-MIBInterfaceIndex
NBS-CMMCENUM-MIBNbsCmmcChannelBand
NBS-MIBNbsTcMHz, nbs
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
NBS-CMMCENUM-MIB
NBS-MIB
NBS-SFF-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
nbsSffObjects
OBJECT-IDENTITY
all MIB objects in nbsSFF MIB.
1.3.6.1.4.1.629.204.1current
nbsSffMsaGrp
OBJECT-IDENTITY
All SFF MSA objects.
1.3.6.1.4.1.629.204.1.1current
nbsSffMsaTable
OBJECT-TYPE
Operations, Administration, and Management information
1.3.6.1.4.1.629.204.1.1.1not-accessiblecurrent
nbsSffMsaEntry
OBJECT-TYPE
Represents a SFF MSA details of a port.
1.3.6.1.4.1.629.204.1.1.1.1not-accessiblecurrent
nbsSffMsaPhysicalIfIndex
OBJECT-TYPE
ifIndex from MIB2
1.3.6.1.4.1.629.204.1.1.1.1.1InterfaceIndexnot-accessiblecurrent
nbsSffMsaIdentifier
OBJECT-TYPE
The MSA Identifier as reported in the MSA memory map, +1. Some of these MSA Identifiers are also represented in nbsCmmcPortType from the NBS-CMMC-MIB: nbsSffMsaIdentifier nbsCmmcPortType ------------------- --------------- gbic (2) gbic (147) sfpTransceiver (4) sfp (125) xfp (7) xfp (197) qsfp (13) qsfp (219) qsfp+ (14) qsfp (219) cfp (15) cfp (221) cxp (16) cxp (220) mrvCxp (130) cxp (220)
1.3.6.1.4.1.629.204.1.1.1.1.2INTEGER {unknown(1), gbic(2), moduleSolderedToBoard(3), sfpTransceiver(4), threeHundredPinXBI(5), xenpak(6), xfp(7), xff(8), xfpe(9), xpak(10), x2(11), dwdm(12), qsfp(13), qsfpPlus(14), cfp(15), cxp(16), mrvCxp(130)}read-onlycurrent
nbsSffMsaExtIdentifier
OBJECT-TYPE
The field should be set to 04h for all SFP modules indicating serial ID module definition. Not supported value: 0
1.3.6.1.4.1.629.204.1.1.1.1.3INTEGERread-onlycurrent
nbsSffMsaOpticalConnector
OBJECT-TYPE
The Optical Connector as reported in the MSA memory map, +1. Here is the list of values: 1 - unknown 2 - SC 3 - Fiber Channel Style 1 copper connector 4 - Fiber Channel Style 2 copper connector 5 - BNC/TNC 6 - Fiber Channel coaxial headers 7 - Fiberjack 8 - LC 9 - MT-RJ 10 - MU 11 - SG 12 - Optical pigtail 13 - MPO Parllel Optic 14 to 32 - Reserved 33 - HSSDC II 34 - Copper pigtail 35 - RJ45 36 to 128 - Reserved -- start InfiniBand Annex A6 (CXP) 48 (30h: Passive Copper Cable Assembly) 49 (31h: Active Copper Cable Assembly (ref. Byte 147)) 50 (32h: Active Optical Cable Assembly) 51 (33h: Optical Transceiver w/ optical connector) -- end InfiniBand Annex A6 (CXP) 129 - firewireA (MRV Specific) 130 - cuRJ45 (MRV Specific) 131 - cuRJ45 with LEDs (MRV Specific) 132 - coaxBNC (MRV Specific) 133 - sataDevicePlug (MRV Specific) 134 - sataHostPlug (MRV Specific) 135 - miniCoax (MRV Specific) 136 to 256 - Vendor specific
1.3.6.1.4.1.629.204.1.1.1.1.4INTEGERread-onlycurrent
nbsSffMsaTransceiverCodes
OBJECT-TYPE
The following bit significant indicators define the electronic or optical interfaces that are supported by the SFP transceiver. At least one bit shall be set in this field. For Fibre Channel SFPs, the Fibre Channel speed, transmission media, transmitter technology, and distance capability shall all be indicated. Reserved Standard Compliance Codes BitIndex Byte Bit Description 3 0-7 Reserved 4 4-7 Reserved SONET Compliance codes 12 4 3 - Reserved 13 4 2 - OC48 Long reach 14 4 1 - OC48 Intermediate reach 15 4 0 - OC48 Short reach 16 5 7 - Reserved 17 5 6 - OC 12 Single mode long reach 18 5 5 - OC 12 Single mode inter reach 19 5 4 - OC 12 Multi-mode short reach 20 5 3 - Reserved 21 5 2 - OC 3 Single mode long reach 22 5 1 - OC 3 Single mode inter reach 23 5 0 - OC 3 Multi-mode short reach Gigabit Ethernet Compliance codes 24-27 6 4-7 - Reserved 28 6 3 - 1000BASE-T 29 6 2 - 1000BASE-CX 30 6 1 - 1000BASE-LX 31 6 0 - 1000BASE-SX Fiber Channel link length 32 7 7 - Very long distance 33 7 6 - Short distance 34 7 5 - Intermediate distance 35 7 4 - Long distance Fibre Channel transmitter technology 36-37 7 2 to 3 - Reserved 38 7 1 - Longwave laser 39 7 0 - Electrical inter-enclosure 40 8 7 - Electrical intra-enclosure 41 8 6 - Shortwave laster without OFC 42 8 5 - Shortwave laster with OFC 43 8 4 - Longwave laser 44-47 8 0 to 3 - Reserved Fiber channel transmission media 48 9 7 - Twin Axial pair 49 9 6 - Shielded Twisted Pair 50 9 5 - Miniature coax 51 9 4 - Video coax 52 9 3 - Multi-mode, 62.5m 53 9 2 - Multi-mode, 50 m 54 9 1 - Reserved 55 9 0 - Single Mode Fiber channel speed 56-58 10 5-7 - Reserved 59 10 4 - 400 MBps 60 10 3 - Reserved 61 10 2 - 200 MBps 62 10 1 - Reserved 63 10 0 - 100 MBps
1.3.6.1.4.1.629.204.1.1.1.1.5OCTET STRING (SIZE(8..11))read-onlycurrent
nbsSffMsaSerialEncoding
OBJECT-TYPE
The encoding value indicates the serial encoding mechanism that is the nominal design target of the particular transceiver. The value shall be contained in the serial data. For XFPs this object must return notSupported, and user should refer to these MIB objects nbsXfpSerialEncodingRZ nbsXfpSerialEncodingNRZ nbsXfpSerialEncodingSonetScrm nbsXfpSerialEncoding8B10B nbsXfpSerialEncoding64B
1.3.6.1.4.1.629.204.1.1.1.1.6INTEGER {notSupported(1), lineCode8To10(2), lineCode4To5(3), nrz(4), manchester(5), sonetScrambled(6), unspecified(7)}read-onlycurrent
nbsSffMsaNominalBitRate
OBJECT-TYPE
The nominal bit rate (BR, nominal) is specified in units of 100 Megabits per second, rounded off to the nearest 100 Megabits per second. The bit rate includes those bits necessary to encode and delimit the signal as well as those bits carrying data information. A value of 0 indicates that the bit rate is not specified and must be determined from the transceiver technology. The actual information transfer rate will depend on the encoding of the data, as defined by the encoding value.
1.3.6.1.4.1.629.204.1.1.1.1.7INTEGERread-onlycurrent
nbsSffMsaLinkLengthSmfKm
OBJECT-TYPE
This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using single mode fiber. The value is in units of kilometers. A value of 255 means that the transceiver supports a link length greater than 254 km. A value of zero means that the transceiver does not support single mode fiber or that the length information must be determined from the transceiver technology. XFP uses this object for the same purpose.
1.3.6.1.4.1.629.204.1.1.1.1.8INTEGERread-onlycurrent
nbsSffMsaLinkLengthSmf100m
OBJECT-TYPE
This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using single mode fiber. The value is in units of 100 meters. A value of 255 means that the transceiver supports a link length greater than 25.4 km. A value of zero means that the transceiver does not support single mode fiber or that the length information must be determined from the transceiver technology.
1.3.6.1.4.1.629.204.1.1.1.1.9INTEGERread-onlycurrent
nbsSffMsaLinkLengthMmf10m
OBJECT-TYPE
This value specifies link length that is supported by the transceiver while operating in compliance with applicable standards using 50 micron multimode OM2 [500MHz*km at 850nm,] fiber. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link length greater than 2.54 km. A value of zero means that the transceiver does not support 50 micron multimode fiber or that the length information must be determined from the transceiver technology.
1.3.6.1.4.1.629.204.1.1.1.1.10INTEGERread-onlycurrent
nbsSffMsaLinkLength625Mmf10m
OBJECT-TYPE
This value specifies link length that is supported by the transceiver while operating in compliance with applicable standards using 62.5 micron multimode OM1 [200 MHz*km at 850nm, 500 MHz*km at 1310nm] fiber. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link length greater than 2.54 km. A value of zero means that the transceiver does not support 62.5 micron multimode fiber or that the length information must determined from the transceiver technology. It is common for a multimode transceiver to support OM1, OM2 and OM3 fiber.
1.3.6.1.4.1.629.204.1.1.1.1.11INTEGERread-onlycurrent
nbsSffMsaCopperLinkLength
OBJECT-TYPE
This value specifies the minimum link length that is supported by the transceiver while operating in compliance with the applicable standards using copper cable. The value is in units of 1 meter. A value of 255 means that the transceiver supports a link length greater than 254 meters. A value of zero means that the transceiver does not support copper cables or that the length information must be determined from the transceiver technology. Further information about the cable design, equalization, and connectors is usually required to guarantee meeting a particular length requirement.
1.3.6.1.4.1.629.204.1.1.1.1.12INTEGERread-onlycurrent
nbsSffMsaVendorName
OBJECT-TYPE
The vendor name is a 16 character field that contains ASCII characters, The vendor name shall be the full name of the corporation, a commonly accepted abbreviation of the name of the corporation, the SCSI company code for the corporation, or the stock exchange code for the corporation. At least one of the vendor name or the vendor OUI fields shall contain valid serial data.
1.3.6.1.4.1.629.204.1.1.1.1.13DisplayString (SIZE(0..16))read-onlycurrent
nbsSffMsaVendorOUI
OBJECT-TYPE
The vendor organizationally unique identifier field (vendor OUI) is a 3-byte field that contains the IEEE Company Identifier for the vendor. A value of all zero in the 3-byte field indicates that the Vendor OUI is unspecified.
1.3.6.1.4.1.629.204.1.1.1.1.14OCTET STRING (SIZE(3))read-onlycurrent
nbsSffMsaVendorPartNumber
OBJECT-TYPE
The vendor part number (vendor PN) is a 16-byte field that contains ASCII characters, left-aligned, defining the vendor part number or product name. Unlike the MSA standard, agent returns size 0 string if the part number is unspecified and there will be no white space padding.
1.3.6.1.4.1.629.204.1.1.1.1.15DisplayString (SIZE(0..16))read-onlycurrent
nbsSffMsaVendorRevision
OBJECT-TYPE
The vendor revision number (vendor rev) is a 4-byte field that contains ASCII characters, defining the vendor's product revision number. Unlike the MSA standard, agent returns size 0 string if the part number is unspecified and there will be no white space padding. This is a two byte string for XFP, four bytes for others.
1.3.6.1.4.1.629.204.1.1.1.1.16DisplayString (SIZE(0..4))read-onlycurrent
nbsSffMsaBaseChecksumMatch
OBJECT-TYPE
The check code is a one byte code that can be used to verify that the first 64 (0-63) bytes of serial information in the SFP transceiver is valid.Returns yes if checksum matches, no if checksum doesn't match. For XFPs, The check code shall be the low order 8 bits of the sum of the contents of all the bytes from byte 128 to byte 190, inclusive.
1.3.6.1.4.1.629.204.1.1.1.1.17INTEGER {no(1), yes(2)}read-onlycurrent
nbsSffMsaLossOfSignalImplemented
OBJECT-TYPE
Byte 65 Bit 1. Signal as defined in the specification
1.3.6.1.4.1.629.204.1.1.1.1.18INTEGERread-onlycurrent
nbsSffMsaLossOfSignalInverted
OBJECT-TYPE
Byte 65 Bit 2. Signal as defined in the specification
1.3.6.1.4.1.629.204.1.1.1.1.19INTEGERread-onlycurrent
nbsSffMsaTxFault
OBJECT-TYPE
Byte 65 Bit 3.TX_FAULT signal implemented. Reset definition in Section III and Laser Fault condition, Generated by laser safety system.
1.3.6.1.4.1.629.204.1.1.1.1.20INTEGER {off(1), on(2)}read-onlycurrent
nbsSffMsaTxDisable
OBJECT-TYPE
Byte 65 Bit 4.TX_DISABLE is implemented and disables the serial output.
1.3.6.1.4.1.629.204.1.1.1.1.21INTEGERread-onlycurrent
nbsSffMsaRateSelectImplemented
OBJECT-TYPE
Byte 65 Bit 5.If this bit is set then active control of the rate select pin is required to change rates. If bit is not set, no control of pin is required. In all cases, compliance with multiple rate standards should be determined by Transceiver codes in bytes 4,5,6, and 10. See table 3.4
1.3.6.1.4.1.629.204.1.1.1.1.22INTEGER {no(1), yes(2)}read-onlycurrent
nbsSffMsaMaxBitRate
OBJECT-TYPE
The upper bit rate limit at which the SFP transceiver will still meet its specifications (BR, max) is specified in units of 1% above the nominal bit rate. A value of zero indicates that this field is not specified.
1.3.6.1.4.1.629.204.1.1.1.1.23INTEGERread-onlycurrent
nbsSffMsaMinBitRate
OBJECT-TYPE
The lower bit rate limit at which the SFP transceiver will still meet its specifications (BR, min) is specified in units of 1% below the nominal bit rate. A value of zero indicates that this field is not specified.
1.3.6.1.4.1.629.204.1.1.1.1.24INTEGERread-onlycurrent
nbsSffMsaVendorSerialNumber
OBJECT-TYPE
The vendor serial number (vendor SN) is a 16 character field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces (20h), defining the vendor's serial number for the SFP transceiver. A value of all zero in the 16-byte field indicates that the vendor SN is unspecified.
1.3.6.1.4.1.629.204.1.1.1.1.25DisplayString (SIZE(0..16))read-onlycurrent
nbsSffMsaVendorDateCode
OBJECT-TYPE
The date code is an 8-byte field that contains the vendor's date code in ASCII characters. The date code is mandatory.
1.3.6.1.4.1.629.204.1.1.1.1.26DisplayString (SIZE(6..8))read-onlycurrent
nbsSffMsaExtChecksumMatch
OBJECT-TYPE
The check code is a one byte code that can be used to verify that the first 32 bytes of extended serial information in the SFP transceiver is valid. The check code shall be the low order 8 bits of the sum of the contents of all the bytes from byte 64 to byte 94, inclusive.
1.3.6.1.4.1.629.204.1.1.1.1.27INTEGER {no(1), yes(2)}read-onlycurrent
nbsSffWdmGrp
OBJECT-IDENTITY
All DWDM MSA objects.
1.3.6.1.4.1.629.204.1.2current
nbsSffWdmTable
OBJECT-TYPE
Operations, Administration, and Management information
1.3.6.1.4.1.629.204.1.2.1not-accessiblecurrent
nbsSffWdmEntry
OBJECT-TYPE
Represents WDM properties of a port.
1.3.6.1.4.1.629.204.1.2.1.1not-accessiblecurrent
nbsSffWdmClassOfPower
OBJECT-TYPE
Extended identifier of class of Power.
1.3.6.1.4.1.629.204.1.2.1.1.1INTEGER {under1W(1), oneToOneAndHalfW(2), overOneAndHalfW(3), reserved(4)}read-onlycurrent
nbsSffWdmClassOfTemperature
OBJECT-TYPE
Extended identifier of class of Temperature. class0 - Temperature in [-5, 70C] class1 - Temperature in [-40, 85C] class2 - reserved class3 - defined by MIB objects nbsSffDwdmMaxCaseTemperature & nbsSffDwdmMinCaseTemperature
1.3.6.1.4.1.629.204.1.2.1.1.2INTEGER {class0(1), class1(2), class2(3), class3(4)}read-onlycurrent
nbsSffWdmClassOfWdm
OBJECT-TYPE
Extended identifier of class of WDM. 1 - No WDM 2 - CWDM 3 - DWDM 4 - Reserved
1.3.6.1.4.1.629.204.1.2.1.1.3INTEGER {noWdm(1), cwdm(2), dwdm(3), reserved(4)}read-onlycurrent
nbsSffWdmOpticalReach
OBJECT-TYPE
This value specifies the link length in kilometers that is supported by the transceiver while operating in compliance with the applicable standards using single mode fiber.
1.3.6.1.4.1.629.204.1.2.1.1.4INTEGERread-onlycurrent
nbsSffWdmMaxCaseTemperature
OBJECT-TYPE
This field defines the maximum operating case temperature in Celsius. For WDMs, this value is in byte 15 in A0h, For XFPs, this value is in byte 190.
1.3.6.1.4.1.629.204.1.2.1.1.5INTEGER (-2147483647..2147483647)read-onlycurrent
nbsSffWdmMinCaseTemperature
OBJECT-TYPE
This field defines the minimum operating case temperature in Celsius.
1.3.6.1.4.1.629.204.1.2.1.1.6INTEGER (-2147483647..2147483647)read-onlycurrent
nbsSffWdmMaxSupplyCurrent
OBJECT-TYPE
This field defines the maximum supply current, in milli Amps, which the module will consume under worst case conditions.
1.3.6.1.4.1.629.204.1.2.1.1.7INTEGERread-onlycurrent
nbsSffWdmNumberOfChannels
OBJECT-TYPE
This specifies the tuning range from 1 to 63, where 1 indicates this module is not tunable by user commands.
1.3.6.1.4.1.629.204.1.2.1.1.8INTEGERread-onlycurrent
nbsSffWdmChannelSpacing
OBJECT-TYPE
This field identifies the densest channel spacing the module is compatible with and the number of channels over which the module may be tuned by user command.
1.3.6.1.4.1.629.204.1.2.1.1.9INTEGER {notTunable(1), ghz50(2), ghz100(3), ghz200(4)}read-onlycurrent
nbsSffWdmVariableDecisionThreshold
OBJECT-TYPE
DWDM Variable Decission Threshold.
1.3.6.1.4.1.629.204.1.2.1.1.10INTEGER {notSupported(1), supported(2)}read-onlycurrent
nbsSffWdmWavelengthMonitorType
OBJECT-TYPE
DWDM Wavelength monitor type in A2 byte.
1.3.6.1.4.1.629.204.1.2.1.1.11INTEGER {wavelength(1), laserTemperature(2)}read-onlycurrent
nbsSffWdmExtTransmitPowerType
OBJECT-TYPE
DWDM Extended Transmit Power Type.
1.3.6.1.4.1.629.204.1.2.1.1.12INTEGER {pwrDefault(1), pwrExtended(2)}read-onlycurrent
nbsSffWdmVariableOpticalAttenuator
OBJECT-TYPE
DWDM Variable Optical Atttenuator.
1.3.6.1.4.1.629.204.1.2.1.1.13INTEGER {notImplemented(1), implemented(2)}read-onlycurrent
nbsSffWdmPilotToneFunctionality
OBJECT-TYPE
DWDM Pilot Tone Functionality.
1.3.6.1.4.1.629.204.1.2.1.1.14INTEGER {pilotToneNone(1), pilotToneDetection(2), pilotToneInjection(3), pilotToneInjectionDetection(4), pilotToneEnhanced(5)}read-onlycurrent
nbsSffWdmOptionalInterruptPin
OBJECT-TYPE
DWDM Optional Interrupt Pin.
1.3.6.1.4.1.629.204.1.2.1.1.15INTEGER {notSupported(1), supported(2)}read-onlycurrent
nbsSffWdmLaserWavelength
OBJECT-TYPE
Nominal transmitter output wavelength. For SFPs, per Specification for DWDM SFP Transceiver, section 2.2.1, The laser wavelength is equal to the 16 bit integer value in nm (16 bit value with byte 60 as high order byte and byte 61 as low order byte) and with the fractional part of the wavelength in units of 0.01nm (byte 62). For XFPs,per specification for INF8077i, see section 5.33
1.3.6.1.4.1.629.204.1.2.1.1.16DisplayString (SIZE(0..150))read-onlycurrent
nbsSffWdmFrequency
OBJECT-TYPE
Nominal transmitter frequency, in MHz
1.3.6.1.4.1.629.204.1.2.1.1.17NbsTcMHzread-onlycurrent
nbsSffWdmChannelBand
OBJECT-TYPE
ITU Channel Band
1.3.6.1.4.1.629.204.1.2.1.1.18NbsCmmcChannelBandread-onlycurrent
nbsSffWdmChannelNumber
OBJECT-TYPE
ITU Channel Number
1.3.6.1.4.1.629.204.1.2.1.1.19INTEGERread-onlycurrent
nbsSffDiagnosticsGrp
OBJECT-IDENTITY
All Diagnostics objects.
1.3.6.1.4.1.629.204.1.3current
nbsSffDiagsTable
OBJECT-TYPE
Operations, Administration, and Management information
1.3.6.1.4.1.629.204.1.3.1not-accessiblecurrent
nbsSffDiagsEntry
OBJECT-TYPE
Represents Digital Diagnostics of a port.
1.3.6.1.4.1.629.204.1.3.1.1not-accessiblecurrent
nbsSffDiagsRateIdentifier
OBJECT-TYPE
The rate identifier byte refers to several (optional) industry standard definitions of Rate_Select or Application_Select control behaviors, intended to manage transceiver optimization for multiple operating rates.
1.3.6.1.4.1.629.204.1.3.1.1.1INTEGER {notSupported(1), rate421G(2), rate842GRx(3), rate842GRxTx(4), rate842GTx(5)}read-onlycurrent
nbsSffDiagsLinkLengthOm3
OBJECT-TYPE
This value specifies link length that is supported by the transceiver while operating in compliance with applicable standards using 50 micron multimode OM3 [2000 MHz*km] fiber. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link length greater than 2.54 km. A value of zero means that the transceiver does not support 50 micron multimode fiber or that the length information must be determined from the transceiver technology.
1.3.6.1.4.1.629.204.1.3.1.1.2INTEGERread-onlycurrent
nbsSffDiagsLaserWavelength
OBJECT-TYPE
Nominal transmitter output wavelength at room temperature. 16 bit value with byte 60 as high order byte and byte 61 as low order byte. The laser wavelength is equal to the the 16 bit integer value in nm. This field allows the user to read the laser wavelength directly, so it is not necessary to infer it from the transceiver Code for Electronic Compatibility (bytes 3 to 10). This also allows specification of wavelengths not covered in bytes 3 to 10, such as those used in coarse WDM systems.
1.3.6.1.4.1.629.204.1.3.1.1.3INTEGERread-onlycurrent
nbsSffDiagsLROutputImplemented
OBJECT-TYPE
Byte 64, bit 0. Value of 1 identifies a conventional limiting (or unspecified) receiver output. Value of 2 identifies a linear receiver output.
1.3.6.1.4.1.629.204.1.3.1.1.4INTEGER {no(1), yes(2)}read-onlycurrent
nbsSffDiagsPowerLevelDeclaration
OBJECT-TYPE
Byte 64, bit 1. Value 1 identifies Power Level 1 (or unspecified) requirements. Value 2 identifies a Power Level2 requirements.
1.3.6.1.4.1.629.204.1.3.1.1.5INTEGER {level1(1), level2(2)}read-onlycurrent
nbsSffDiagsCooledTranDeclaration
OBJECT-TYPE
Byte 64, bit 2. Value 1 identifies a conventional uncooled (or unspecified) laser implementation. Value 2 identifies a cooled laser transmitter implementation.
1.3.6.1.4.1.629.204.1.3.1.1.6INTEGER {uncooled(1), cooled(2)}read-onlycurrent
nbsSffDiagsAddressChangeRequired
OBJECT-TYPE
Byte 92, bit 2 indicates whether or not it is necessary for the host to perform an address change sequence before accessing information at 2-wire serial address A2h. If this bit is not set, the host may simply read from either address, A0h or A2h, by using that value in the address byte during the 2-wire communication sequence. If the bit is set, the defined sequence must be executed prior to accessing information at address A2h.
1.3.6.1.4.1.629.204.1.3.1.1.7INTEGER {no(1), yes(2)}read-onlycurrent
nbsSffDiagsPowerMeasurementType
OBJECT-TYPE
Byte 92, bit 3 indicates whether the received power measurement represents average input optical power or OMA. If the bit is set, average power is monitored. If it is not, OMA is monitored. For XFPs, the address location would be byte 220, bit 3
1.3.6.1.4.1.629.204.1.3.1.1.8INTEGER {oma(1), averagePower(2)}read-onlycurrent
nbsSffDiagsExternallyCalibrated
OBJECT-TYPE
Byte 92, bit 4 Externally Calibrated Two calibration options are possible if bit 6 has been set indicating that digital diagnostic monitoring has been implemented. If bit 4 is set, the reported values are A/D counts which must be converted to real world units using calibration values read using 2 wire serial address 1010001X (A2h) from bytes 56 to 95.
1.3.6.1.4.1.629.204.1.3.1.1.9INTEGER {no(1), yes(2)}read-onlycurrent
nbsSffDiagsInternallyCalibrated
OBJECT-TYPE
Byte 92, bit 5 Internally Calibrated. Two calibration options are possible if bit 6 has been set indicating that digital diagnostic monitoring has been implemented. If bit 5, Internally calibrated is set, the transceiver directly reports calibrated values in units of current, power etc.
1.3.6.1.4.1.629.204.1.3.1.1.10INTEGER {no(1), yes(2)}read-onlycurrent
nbsSffDiagsDDMonitoringImplemented
OBJECT-TYPE
Byte 92, bit 6. If this bit is set indicating that digital diagnostic monitoring has been implemented, received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring must all be implemented. Additionally, alarm and warning thresholds must be written as specified in this document at locations 00 to 55 on 2 wire serial address 1010001X (A2h)
1.3.6.1.4.1.629.204.1.3.1.1.11INTEGER {no(1), yes(2)}read-onlycurrent
nbsSffDiagsOptRateSelectControl
OBJECT-TYPE
Byte 93 bit 1. Optional Rate Select control implemented per SFF-8431. Sets to 1 if not implemented, 2 if implemented.
1.3.6.1.4.1.629.204.1.3.1.1.12INTEGER {notImplemented(1), implemented(2)}read-onlycurrent
nbsSffDiagsOptAppSelectControl
OBJECT-TYPE
Based on byte 93 bit 2. Optional Application Select control implemented per SFF-8079. Sets to 1 if not implemented, 2 if implemented.
1.3.6.1.4.1.629.204.1.3.1.1.13INTEGER {notImplemented(1), implemented(2)}read-onlycurrent
nbsSffDiagsOptSoftRSControlMon
OBJECT-TYPE
Based on byte 93 bit 3. Optional soft RATE_SELECT control and monitoring implemented. Sets to 1 if not implemented, 2 if implemented.
1.3.6.1.4.1.629.204.1.3.1.1.14INTEGER {notImplemented(1), implemented(2)}read-onlycurrent
nbsSffDiagsOptSoftRxLoSMonitoring
OBJECT-TYPE
Based on byte 93 bit 4. Optional soft RX_LOS monitoring implemented. Sets to 1 if not implemented, 2 if implemented.
1.3.6.1.4.1.629.204.1.3.1.1.15INTEGER {notImplemented(1), implemented(2)}read-onlycurrent
nbsSffDiagsOptSoftTxFaultMonitoring
OBJECT-TYPE
Based on byte 93 bit 5. Optional soft TX_FAULT monitoring implemented. Sets to 1 if not implemented, 2 if implemented.
1.3.6.1.4.1.629.204.1.3.1.1.16INTEGER {notImplemented(1), implemented(2)}read-onlycurrent
nbsSffDiagsOptSoftTxDisable
OBJECT-TYPE
Based on byte 93 bit 6. Optional soft TX_DISABLE control and monitoring implemented.Sets to 1 if not implemented, 2 if implemented.
1.3.6.1.4.1.629.204.1.3.1.1.17INTEGER {notImplemented(1), implemented(2)}read-onlycurrent
nbsSffDiagsOptAlarmWarningFlags
OBJECT-TYPE
Based on byte 93 bit 7. Optional Alarm/warning flags implemented for all monitored quantities.Sets to 1 if not implemented, 2 if implemented. See Table 3.18
1.3.6.1.4.1.629.204.1.3.1.1.18INTEGER {notImplemented(1), implemented(2)}read-onlycurrent
nbsSffDiags8472Compliance
OBJECT-TYPE
Byte 94 contains an unsigned integer that indicates which feature set(s) are implemented in the transceiver.
1.3.6.1.4.1.629.204.1.3.1.1.19INTEGER {notSupported(1), rev9dot3of8472(2), rev9dot5of8472(3), rev10dot2of8472(4), rev10dot4of8472(5), rev11dot0of8472(6), rev11dot3of8472(7), rev11dot4of8472(8), rev12dot0of8472(9), unallocated(256)}read-onlycurrent
nbsSffDiagsTemperature
OBJECT-TYPE
Module temperature in centigradese.
1.3.6.1.4.1.629.204.1.3.1.1.20INTEGER (-2147483647..2147483647)read-onlycurrent
nbsSffDiagsTempLowAlarm
OBJECT-TYPE
Predefined temperature for low alarm threshold in Centigrades.
1.3.6.1.4.1.629.204.1.3.1.1.21INTEGERread-onlycurrent
nbsSffDiagsTempLowWarn
OBJECT-TYPE
Predefined temperature for low warning threshold in Centigrades
1.3.6.1.4.1.629.204.1.3.1.1.22INTEGERread-onlycurrent
nbsSffDiagsTempHighWarn
OBJECT-TYPE
Predefined temperature for high warning threshold in Centigrades
1.3.6.1.4.1.629.204.1.3.1.1.23INTEGERread-onlycurrent
nbsSffDiagsTempHighAlarm
OBJECT-TYPE
Predefined temperature for high alarm threshold in Centigrades
1.3.6.1.4.1.629.204.1.3.1.1.24INTEGERread-onlycurrent
nbsSffDiagsVoltage
OBJECT-TYPE
Internally measured supply voltage in transceiver in the units of Volts. Bytes 98 & 99 of Address A2h
1.3.6.1.4.1.629.204.1.3.1.1.25DisplayString (SIZE(0..16))read-onlycurrent
nbsSffDiagsVoltLowAlarm
OBJECT-TYPE
Predefined voltage for low alarm threshold in the units of Volts.
1.3.6.1.4.1.629.204.1.3.1.1.26INTEGERread-onlycurrent
nbsSffDiagsVoltLowWarn
OBJECT-TYPE
Predefined voltage for low warning threshold in the units of Volts.
1.3.6.1.4.1.629.204.1.3.1.1.27INTEGERread-onlycurrent
nbsSffDiagsVoltHighWarn
OBJECT-TYPE
Predefined voltage for high warning threshold in the units of Volts.
1.3.6.1.4.1.629.204.1.3.1.1.28INTEGERread-onlycurrent
nbsSffDiagsVoltHighAlarm
OBJECT-TYPE
Predefined voltage for high alarm threshold in the units of Volts.
1.3.6.1.4.1.629.204.1.3.1.1.29INTEGERread-onlycurrent
nbsSffDiagsBiasCurrent
OBJECT-TYPE
Internally measured TX Bias Current in the units of mA. Bytes 100 & 101 of Address A2h
1.3.6.1.4.1.629.204.1.3.1.1.30DisplayString (SIZE(0..16))read-onlycurrent
nbsSffDiagsBiasLowAlarm
OBJECT-TYPE
Predefined bias current for low alarm threshold in the units of mA
1.3.6.1.4.1.629.204.1.3.1.1.31INTEGERread-onlycurrent
nbsSffDiagsBiasLowWarn
OBJECT-TYPE
Predefined bias current for low warning threshold in the units of mA
1.3.6.1.4.1.629.204.1.3.1.1.32INTEGERread-onlycurrent
nbsSffDiagsBiasHighWarn
OBJECT-TYPE
Predefined bias current for high warning threshold in the units of mA
1.3.6.1.4.1.629.204.1.3.1.1.33INTEGERread-onlycurrent
nbsSffDiagsBiasHighAlarm
OBJECT-TYPE
Predefined bias current for high alarm threshold in the units of mA
1.3.6.1.4.1.629.204.1.3.1.1.34INTEGERread-onlycurrent
nbsSffDiagsTxPower
OBJECT-TYPE
Measured TX output power in the units of dBm.
1.3.6.1.4.1.629.204.1.3.1.1.35DisplayString (SIZE(0..16))read-onlycurrent
nbsSffDiagsTxPowerLowAlarm
OBJECT-TYPE
Predefined Tx output power for low alarm threshold in the units of dBm.
1.3.6.1.4.1.629.204.1.3.1.1.36INTEGERread-onlycurrent
nbsSffDiagsTxPowerLowWarn
OBJECT-TYPE
Predefined Tx output power for low warning threshold in the units of dBm.
1.3.6.1.4.1.629.204.1.3.1.1.37INTEGERread-onlycurrent
nbsSffDiagsTxPowerHighWarn
OBJECT-TYPE
Predefined Tx output power for high warning threshold in the units of dBm.
1.3.6.1.4.1.629.204.1.3.1.1.38INTEGERread-onlycurrent
nbsSffDiagsTxPowerHighAlarm
OBJECT-TYPE
Predefined Tx output power for high alarm threshold in the units of dBm.
1.3.6.1.4.1.629.204.1.3.1.1.39INTEGERread-onlycurrent
nbsSffDiagsRxPower
OBJECT-TYPE
Measured received optical power. Received power, RX_PWR, is given in uW by the following equation: Rx_PWR (uW) = Rx_PWR(4) * Rx_PWR AD 4 (16 bit unsigned integer) + Rx_PWR(3) * Rx_PWR AD 3 (16 bit unsigned integer) + Rx_PWR(2) * Rx_PWR AD 2 (16 bit unsigned integer) + Rx_PWR(1) * Rx_PWR AD (16 bit unsigned integer) + Rx_PWR(0)
1.3.6.1.4.1.629.204.1.3.1.1.40DisplayString (SIZE(0..16))read-onlycurrent
nbsSffDiagsRxPowerLowAlarm
OBJECT-TYPE
Predefined Rx input power for low alarm threshold in the units of dBm.
1.3.6.1.4.1.629.204.1.3.1.1.41INTEGERread-onlycurrent
nbsSffDiagsRxPowerLowWarn
OBJECT-TYPE
Predefined Rx input power for low warning threshold in the units of dBm.
1.3.6.1.4.1.629.204.1.3.1.1.42INTEGERread-onlycurrent
nbsSffDiagsRxPowerHighWarn
OBJECT-TYPE
Predefined Rx input power for high warning threshold in the units of dBm.
1.3.6.1.4.1.629.204.1.3.1.1.43INTEGERread-onlycurrent
nbsSffDiagsRxPowerHighAlarm
OBJECT-TYPE
Predefined Rx input power for high alarm threshold in the units of dBm.
1.3.6.1.4.1.629.204.1.3.1.1.44INTEGERread-onlycurrent
nbsSffDiagsDataReadyBarState
OBJECT-TYPE
Indicates transceiver has achieved power up and data is ready. Bit remains high until data is ready to be read at which time the device sets the bit low. Byte 110, bit 0 of A2h
1.3.6.1.4.1.629.204.1.3.1.1.45INTEGERread-onlycurrent
nbsSffDiagsRxLosState
OBJECT-TYPE
Digital state of the RX_LOS Output Pin. Updated within 100ms of change on pin. Byte 110, bit 1 of A2h
1.3.6.1.4.1.629.204.1.3.1.1.46INTEGERread-onlycurrent
nbsSffDiagsTxFaultState
OBJECT-TYPE
Digital state of the TX Fault Output Pin. Updated within 100ms of change on pin. Byte 110, bit 2 of A2h
1.3.6.1.4.1.629.204.1.3.1.1.47INTEGERread-onlycurrent
nbsSffDiagsSoftRateSelect
OBJECT-TYPE
Read/write bit that allows software rate select control. Writing 1 selects full bandwidth operation. This bit is OR'd with the hard Rate_Select, AS(0) or RS(0) pin value. See Table 3.11 for timing requirements. Default at power up is logic zero/low. If Soft Rate Select is not implemented, the transceiver ignores the value of this bit. Note: Specific transceiver behaviors of this bit are identified in Table 3.6a and referenced documents. See Table 3.18a, byte 118, bit 3 for Soft RS(1) Select. Byte 110, bit 3 of A2h
1.3.6.1.4.1.629.204.1.3.1.1.48INTEGERread-onlycurrent
nbsSffDiagsRateSelectState0
OBJECT-TYPE
Digital state of the SFP Rate_Select Input Pin. Updated within 100ms of change on pin. Note: This pin is also known as AS(0) in SFF-8079 and RS(0) in SFF-8431. Byte 110, bit 4 of A2h
1.3.6.1.4.1.629.204.1.3.1.1.49INTEGERread-onlycurrent
nbsSffDiagsRS1State
OBJECT-TYPE
Reserved for digital state of input pin AS(1) per SFF-8079 and RS(1) per SFF-8431. Updated within 100ms of change on pin. See A2h Byte 118, Bit 3 for Soft RS(1) Select control information. Byte 110, bit 5 of A2h
1.3.6.1.4.1.629.204.1.3.1.1.50INTEGERread-onlycurrent
nbsSffDiagsSoftTxDisableSelect
OBJECT-TYPE
Read/write bit that allows software disable of laser. Writing 1 disables laser. See Table 3.11 for enable/ disable timing requirements. This bit is OR d with the hard TX_DISABLE pin value. Note, per SFP MSA TX_DISABLE pin is default enabled unless pulled low by hardware. If Soft TX Disable is not implemented, the transceiver ignores the value of this bit. Default power up value is zero/low. Byte 110, bit 6 of A2h
1.3.6.1.4.1.629.204.1.3.1.1.51INTEGERread-onlycurrent
nbsSffDiagsTxDisableState
OBJECT-TYPE
Digital state of the TX Disable Input Pin. Updated within 100ms of change on pin.
1.3.6.1.4.1.629.204.1.3.1.1.52INTEGERread-onlycurrent
nbsSffDiagsBiasCurrentSlope
OBJECT-TYPE
Fixed decimal (unsigned) calibration data, laser bias current measured in mA.
1.3.6.1.4.1.629.204.1.3.1.1.53DisplayString (SIZE(0..16))read-onlycurrent
nbsSffDiagsBiasCurrentOffset
OBJECT-TYPE
Fixed decimal (signed two's complement) calibration data, laser bias current measured in mA.
1.3.6.1.4.1.629.204.1.3.1.1.54INTEGERread-onlycurrent
nbsSffDiagsTxPowerSlope
OBJECT-TYPE
Fixed decimal (unsigned) calibration data, transmitter coupled output power in the units of dBm.
1.3.6.1.4.1.629.204.1.3.1.1.55DisplayString (SIZE(0..16))read-onlycurrent
nbsSffDiagsTxPowerOffset
OBJECT-TYPE
Fixed decimal (signed two's complement) calibration data, transmitter coupled output power in the units of dBm.
1.3.6.1.4.1.629.204.1.3.1.1.56INTEGERread-onlycurrent
nbsSffDiagsTemperatureSlope
OBJECT-TYPE
Fixed decimal (unsigned) calibration data, internal module temperature in C
1.3.6.1.4.1.629.204.1.3.1.1.57DisplayString (SIZE(0..16))read-onlycurrent
nbsSffDiagsTemperatureOffset
OBJECT-TYPE
Fixed decimal (signed two's complement) calibration data, internal module temperature in C
1.3.6.1.4.1.629.204.1.3.1.1.58INTEGERread-onlycurrent
nbsSffDiagsVoltageSlope
OBJECT-TYPE
Fixed decimal (unsigned) calibration data, internal module supply voltage in Volts.
1.3.6.1.4.1.629.204.1.3.1.1.59DisplayString (SIZE(0..16))read-onlycurrent
nbsSffDiagsVoltageOffset
OBJECT-TYPE
Fixed decimal (signed two's complement) calibration data, internal module supply voltage in Volts.
1.3.6.1.4.1.629.204.1.3.1.1.60INTEGERread-onlycurrent
nbsSffDiagsPowerLevelSelect
OBJECT-TYPE
Reserved for SFF-8431 Power Level (maximum power dissipation) enable. Value of zero disables Power Level 2 (1.0 Watt max). Value of one enables Power Level 2 (1.5 Watt max). Refer to Table 3.7 for Power Level declaration. Refer to Table 3.11 for timing.
1.3.6.1.4.1.629.204.1.3.1.1.61INTEGER {off(1), on(2)}read-onlycurrent
nbsSffDiagsPowerLevelOpState
OBJECT-TYPE
Reserved for SFF-8431 Power Level (maximum power dissipation) status.Value of zero indicates Power Level 1 operation (1.0 Watt max) Value of one indicates Power Level 2 operation (1.5 Watt max).Refer to Table 3.7 for Power Level declaration. Refer to Table 3.11 for timing.
1.3.6.1.4.1.629.204.1.3.1.1.62INTEGER {off(1), on(2)}read-onlycurrent
nbsSffDiagsSoftRSSelect
OBJECT-TYPE
Read/write bit that allows software Tx rate control. Writing 1 selects full speed Tx operation. This bit is OR d with the hard RS(1) pin value.See Table 3.11 for timing requirements. Default at power up is logic zero/low. If Soft RS(1) is not implemented, the transceiver ignores the value of this bit. Note: Specific transceiver behaviors of this bit are identified in Table 3.6a and referenced documents. See Table 3.17, byte 110, bit 3 for Soft RS(0) Select.
1.3.6.1.4.1.629.204.1.3.1.1.63INTEGER {off(1), on(2)}read-onlycurrent
nbsSffMsxGrp
OBJECT-IDENTITY
All SFF MSA Extension objects.
1.3.6.1.4.1.629.204.1.4current
nbsSffMsxTableSize
OBJECT-TYPE
The number of entries in nbsSffMsxTable
1.3.6.1.4.1.629.204.1.4.1Unsigned32read-onlycurrent
nbsSffMsxTable
OBJECT-TYPE
Non-standardized extensions to the Multi-Source Agreement
1.3.6.1.4.1.629.204.1.4.2not-accessiblecurrent
nbsSffMsxEntry
OBJECT-TYPE
Pluggable Transceiver information and settings yet to be standardized
1.3.6.1.4.1.629.204.1.4.2.1not-accessiblecurrent
nbsSffMsxPhysicalIfIndex
OBJECT-TYPE
MIB2 ifIndex of this port
1.3.6.1.4.1.629.204.1.4.2.1.1InterfaceIndexread-onlycurrent
nbsSffMsxHasSgmiiPhy
OBJECT-TYPE
Some Gigabit Ethernet compatible SFP transeivers, such as SFP-FDSGMII-M and SFP-FDSGMII-LR, have a built-in SGMII PHY. Those that do require special autonegotiation processing, without which autonegotiation will fail and the port will be unable to pass traffic. If the SFP has a built-in SGMII PHY, the user should set this to yes(3).
1.3.6.1.4.1.629.204.1.4.2.1.2INTEGER {notSupported(1), no(2), yes(3)}read-writecurrent