MY-SYSTEM-MIB
- Registered at
- 1.3.6.1.4.1.4881.1.1.10.2.1
- Last updated
- 2002-03-20 00:00
- Organization
- $Company$
- Revisions
- 2002-03-20 00:00
- Namespace
- ruijie
- Source file
MY-SYSTEM-MIB- Digest
sha256:871e57b2ad1b69e69c90831e4d1baf7cc31f81b2bc9802e051357c1d118faa9c
Description
This module defines my system mibs.
Contact
Tel: $Telephone$ E-mail: $E-mail$
Imports
| From | Symbols |
|---|---|
| MY-SMI | myMgmt |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, RowStatus, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
MY-SMI MY-SYSTEM-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| mySystemMIBObjects OBJECT-IDENTITY | 1.3.6.1.4.1.4881.1.1.10.2.1.1 | |||
| mySystemHwVersion OBJECT-TYPE Return the string of the Revision number of hardware resides on the FastSwitch. | 1.3.6.1.4.1.4881.1.1.10.2.1.1.1 | DisplayString (SIZE(1..32)) | read-only | current |
| mySystemSwVersion OBJECT-TYPE Return the string of the Revision number of software resides on the FastSwitch. | 1.3.6.1.4.1.4881.1.1.10.2.1.1.2 | DisplayString (SIZE(1..32)) | read-only | current |
| mySystemBootVersion OBJECT-TYPE Return the string of the Revision number of BOOT software resides on the FastSwitch. | 1.3.6.1.4.1.4881.1.1.10.2.1.1.3 | DisplayString (SIZE(1..32)) | read-only | current |
| mySystemSysCtrlVersion OBJECT-TYPE Return the string of the Revision number of CTRL software resides on the FastSwitch. | 1.3.6.1.4.1.4881.1.1.10.2.1.1.4 | DisplayString (SIZE(1..32)) | read-only | current |
| mySystemParametersSave OBJECT-TYPE Save all parameters changed in configuration by setting this object to any value but 0, set its value to 0 will cause no action of agent, otherwise all changes of prarameters will be saved for retrive when system is reset, if parameter is changed but not saved all changes will come to their original value when system down and up again, when query always return value 0. | 1.3.6.1.4.1.4881.1.1.10.2.1.1.5 | Integer32 | read-write | current |
| mySystemOutBandRate OBJECT-TYPE Determine the console(OutBand) baud rate : 9600 - 1,19200 - 2, 38300 - 3, 57600 - 4 | 1.3.6.1.4.1.4881.1.1.10.2.1.1.6 | INTEGER {baud9600(1), baud19200(2), baud38400(3), baud57600(4)} | read-write | current |
| mySystemReset OBJECT-TYPE This Object allow perform soft reset of system by setting its value to none zero. if a soft resetis performed, after this having completed a warm start trap will send to declare the state and when queried will always return 0. | 1.3.6.1.4.1.4881.1.1.10.2.1.1.7 | INTEGER | read-write | current |
| mySwitchLayer OBJECT-TYPE Which layer's device the switch in system | 1.3.6.1.4.1.4881.1.1.10.2.1.1.8 | INTEGER {layer2(1), layer3(2)} | read-only | current |
| mySystemHwPower OBJECT-TYPE The state of power. | 1.3.6.1.4.1.4881.1.1.10.2.1.1.9 | INTEGER {rpsNoLink(1), rpsLinkAndNoPower(2), rpsLinkAndReadyForPower(3), rpsLinkAndPower(4)} | read-only | current |
| mySystemHwFan OBJECT-TYPE The state of fan. | 1.3.6.1.4.1.4881.1.1.10.2.1.1.10 | INTEGER {work(1), stop(2)} | read-only | current |
| mySystemOutBandTimeout OBJECT-TYPE The timeout of console.0 indicate that timeout function is disabled. | 1.3.6.1.4.1.4881.1.1.10.2.1.1.11 | Integer32 (0..3600) | read-write | obsolete |
| mySystemTelnetTimeout OBJECT-TYPE The timeout of telnet.0 indicate that timeout function is disabled. | 1.3.6.1.4.1.4881.1.1.10.2.1.1.12 | Integer32 (0..3600) | read-write | obsolete |
| mySystemMIBTraps OBJECT-IDENTITY | 1.3.6.1.4.1.4881.1.1.10.2.1.2 | |||
| mySystemHardChangeDesc OBJECT-TYPE The description of hard change | 1.3.6.1.4.1.4881.1.1.10.2.1.2.1 | DisplayString | accessible-for-notify | current |
| mySystemMIBConformance OBJECT-IDENTITY | 1.3.6.1.4.1.4881.1.1.10.2.1.3 | |||
| mySystemMIBCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.4881.1.1.10.2.1.3.1 | |||
| mySystemMIBGroups OBJECT-IDENTITY | 1.3.6.1.4.1.4881.1.1.10.2.1.3.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| mySystemHardChangeDetected NOTIFICATION-TYPE System hardware has changed include number of devices or number of modules or the place or type of the module is change. | 1.3.6.1.4.1.4881.1.1.10.2.1.2.2 | current |
| mySystemPowerStateChange NOTIFICATION-TYPE while the state of power changed, then this trap will be sent. | 1.3.6.1.4.1.4881.1.1.10.2.1.2.3 | current |
| mySystemFanStateChange NOTIFICATION-TYPE while the state of fan changed, then this trap will be sent. | 1.3.6.1.4.1.4881.1.1.10.2.1.2.4 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| mySystemMIBCompliance MODULE-COMPLIANCE The compliance statement for entities which implement the My System MIB | 1.3.6.1.4.1.4881.1.1.10.2.1.3.1.1 | current |
| mySystemMIBGroup OBJECT-GROUP A collection of objects providing system information and opertion to a My agent. | 1.3.6.1.4.1.4881.1.1.10.2.1.3.2.1 | current |