MIBs Depot

MICROSEMI-PDSINE-MIB

Registered at
1.3.6.1.4.1.7428
Last updated
2011-11-15 00:00
Namespace
microsemi
Source file
MICROSEMI-PDSINE-MIB
Digest
sha256:23680efcf6de617c9f56f1a7c792c6853e5846b3de36cfdf149a33f3f6b6f203

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

MICROSEMI-PDSINE-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
products
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1
description
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1
sysObjectID
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1
midspanUnknown
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.1
midspan6portAC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.2
midspan6portACDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.3
midspan12portAC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.4
midspan12portACDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.5
midspan24portAC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.6
midspan24portACDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.7
midspan48portAC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.8
midspan48portACDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.9
midspan6portHPAC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.10
midspan6portHPACDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.11
midspan12portHPAC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.12
midspan12portHPACDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.13
midspanGigabit6portAC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.14
midspanGigabit12portAC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.15
midspanGigabit24portAC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.16
midspanHiPoEGigabit6portAC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.17
midspanHiPoEGigabit12portAC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.18
midspanHiPoEGigabit24portAC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.19
midspanHiPoEATGigabit6portAC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.20
midspanHiPoEATGigabit12portACDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.21
midspanHiPoEATGigabit24portACDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.22
midspan4PairATGigabit6portACDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.23
midspan4PairATGigabit12portACDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.24
midspanHiPoEATGigabit6portDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.25
midspanHiPoEATGigabit12portDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.26
midspanHiPoEATGigabit24portDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.27
midspan4PairATGigabit24portACDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.28
midspanEEPoEGigabit24portACDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.29
midspanPoHGigabit6portACDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.30
midspanPoHGigabit12portACDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.31
midspanPoHGigabit24portACDC
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.1.1.32
pseDevice
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.2
portObjects
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.2.1
portTable
OBJECT-TYPE
A table of objects that display and control the power characteristics of power Ethernet ports on a Power Source Entity (PSE) device. This group will be implemented in managed power Ethernet switches and mid-span devices. Values of all read-write objects in this table are persistent at restart/reboot.
1.3.6.1.4.1.7428.1.2.1.1not-accessiblecurrent
portEntry
OBJECT-TYPE
A set of objects that display and control the power characteristics of a power Ethernet PSE port.
1.3.6.1.4.1.7428.1.2.1.1.1not-accessiblecurrent
portGroupIndex
OBJECT-TYPE
This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices.
1.3.6.1.4.1.7428.1.2.1.1.1.1Integer32 (1..2147483647)not-accessiblecurrent
portIndex
OBJECT-TYPE
This variable uniquely identifies the power Ethernet PSE port within group portGroupIndex to which the power Ethernet PSE entry is connected.
1.3.6.1.4.1.7428.1.2.1.1.1.2Integer32 (1..2147483647)not-accessiblecurrent
portConsumptionPower
OBJECT-TYPE
A read-only value indicates the measured usage power expressed in Watts for a specific port
1.3.6.1.4.1.7428.1.2.1.1.1.3Gauge32read-onlycurrent
portMaxPower
OBJECT-TYPE
Read/Write maximum power consumption that PD device may consume in Watts NOTE: 1. For Midspan 60xx,60xxG,6500 series, Max PD power consumption = 17Watt 2. For Midspan 70xxG series, Max PD power consumption = 30Watt 3 .For Midspan 80xx series, this parameter is read-only !! 4. For Midspan 90xxG series, Max PD power consumption = 30/36Watt 5. For Midspan 95xxG series, Max PD power consumption = 60/72Watt (four pair) or 30/36Watt (two pair) 6. For Midspan 55xxG series, Max PD power consumption = 30/36Watt
1.3.6.1.4.1.7428.1.2.1.1.1.4Integer32 (1..99)read-writecurrent
portType
OBJECT-TYPE
Enable/Disable Four-pair/EEPoE PoE Read : Applicable to all Midspan series Write: Applicable only to 95xxG/55xxG Midspan series twopair (1) Two-pair PoE port capable of providing up to 16.8Watt or 30-36Watt. fourpair (2) Four-pair/EEPoE-mode PoE port capable of providing up to 60-72Watt (95xxG) or 30-36W (55xxG).
1.3.6.1.4.1.7428.1.2.1.1.1.5INTEGER {twopair(1), fourpair(2)}read-writecurrent
mainObjects
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.2.2
mainPseTable
OBJECT-TYPE
A table of objects that display and control attributes of the main PSE device.
1.3.6.1.4.1.7428.1.2.2.1not-accessiblecurrent
mainPseEntry
OBJECT-TYPE
A set of objects that display and control the Main PSE device.
1.3.6.1.4.1.7428.1.2.2.1.1not-accessiblecurrent
mainGroupIndex
OBJECT-TYPE
This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices.
1.3.6.1.4.1.7428.1.2.2.1.1.1Integer32 (1..2147483647)not-accessiblecurrent
mainVoltage
OBJECT-TYPE
Power Supply Voltage in Volt.
1.3.6.1.4.1.7428.1.2.2.1.1.2Gauge32 (1..65535)read-onlycurrent
mainDetectionMethod
OBJECT-TYPE
Read/Write PD device detection method (802.3af / 802.3af+Legacy).
1.3.6.1.4.1.7428.1.2.2.1.1.3INTEGER {ieee8023afat(1), ieee8023afatandlegacy(2)}read-writecurrent
mainPowerUsageBudget
OBJECT-TYPE
Allow external SNMP manager to limit maximum power that all PD's may consume Whenever total power consumption exceeds maximum power, Midspan may turn off automatically Low priority and High priority PSE ports. Percentage Value refers to Midspan maximum power.
1.3.6.1.4.1.7428.1.2.2.1.1.4Integer32 (10..100)read-writecurrent
mainPSEMaxPower
OBJECT-TYPE
Maximum power that Midspan can provide (Watt), after including power budget percentage limitation. Example: Midspan maximum power without power limit = 860Watt, and Power Limit = 50% mainPSEMaxPower = 430Watt
1.3.6.1.4.1.7428.1.2.2.1.1.5Gauge32 (1..65535)read-onlycurrent
highPowerLegacyPDSupport
OBJECT-TYPE
Applicable only for Midspan 90xxG series enable (1) - Power Cisco 125x access point (pre 802.3at legacy high power PD device). disable(2) - Power only 802.3at compliant devices. notsupported(3) - SNMP GET result for Midspan which doesn't support this feature
1.3.6.1.4.1.7428.1.2.2.1.1.6INTEGER {enable(1), disable(2), notsupported(3)}read-writecurrent
highPowerExtendedPortPower
OBJECT-TYPE
Applicable only for Midspan 90xxG/55xxG series enable (1) - Extend maximum power to PD device beyond 802.3at specification. disable(2) - Maximum power to PD device per 802.3at specification. notsupported(3) - SNMP GET result for Midspan which doesn't support this feature
1.3.6.1.4.1.7428.1.2.2.1.1.7INTEGER {enable(1), disable(2), notsupported(3)}read-writecurrent
powerBackupStatus
OBJECT-TYPE
Applicable only for Midspan 90xxG/95xxG/55xxG series standalone - Midspan isn't connected to any power backup device powerbackupbyrps - Redundant power supply (RPS) backup Midspan device powerbackupbymidspan - Two Midspan devices backup each other incompatiblepowerbackupdevice - Midspan was connected to incompatible power backup device. For example RPS 430Watt to Midspan 950Watt
1.3.6.1.4.1.7428.1.2.2.1.1.8INTEGER {standalone(1), powerbackupbyrps(2), powerbackupbymidspan(3), incompatiblepowerbackupdevice(4)}read-onlycurrent
internalPowerSourceStatus
OBJECT-TYPE
Applicable only for Midspan 90xxG/95xxG/55xxG series ok(1) - Internal Power Source is OK fail(2) - Internal Power Source failure
1.3.6.1.4.1.7428.1.2.2.1.1.9INTEGER {ok(1), fail(2)}read-onlycurrent
externalPowerSourceStatus
OBJECT-TYPE
Applicable only for Midspan 90xxG/95xxG/55xxG series ok(1) - External Power Source is OK fail(2) - External Power Source failure notsupported(3) - SNMP GET result for Midspan which doesn't support this feature
1.3.6.1.4.1.7428.1.2.2.1.1.10INTEGER {ok(1), fail(2), notsupported(3)}read-onlycurrent
temperature
OBJECT-TYPE
Unit temperature - Applicable only for Midspan 95xxG series
1.3.6.1.4.1.7428.1.2.2.1.1.11INTEGERread-onlycurrent
temperatureformat
OBJECT-TYPE
Unit temperature format - Applicable only for Midspan 95xxG series Celcius(1) - Report unit temperature in Celcius Fahrenheit(2) - Report unit temperature in Fahrenheit NotSupported(3) - No temperature sensor inside the Midspan unit
1.3.6.1.4.1.7428.1.2.2.1.1.12INTEGER {celcius(1), fahrenheit(2), notsupported(3)}read-writecurrent
poeNotifications
OBJECT-IDENTITY
1.3.6.1.4.1.7428.1.3

Notifications

NameOIDStatus
powerBackupStatusNotification
NOTIFICATION-TYPE
Applicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports power backup status change, and whenever incompatible power backup source is connected (as RPS 430Watt to Midspan 950Watt)
1.3.6.1.4.1.7428.1.3.1current
internalPowerSourceStatusNotification
NOTIFICATION-TYPE
Applicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports internal Power Source failure
1.3.6.1.4.1.7428.1.3.2current
externalPowerSourceStatusNotification
NOTIFICATION-TYPE
Applicable only for Midspan 90xxG/95xxG/55xxG series This Notification reports external Power Source failure
1.3.6.1.4.1.7428.1.3.3current