MBG-SNMP-LTNG-MIB
- Registered at
- 1.3.6.1.4.1.5597.30
- Last updated
- 2016-05-18 05:17
- Organization
- Meinberg Radio Clocks GmbH & Co. KG
- Revisions
- 2016-05-18 05:17, 2015-08-27 08:44, 2015-04-17 06:32, 2014-11-25 07:24, 2014-08-29 08:10, 2014-01-30 09:19, 2013-11-01 09:39, 2013-10-09 11:50, 2013-10-01 08:10, 2013-09-18 12:16, 2013-02-20 07:00, 2012-11-07 14:20, 2012-03-30 07:13, 2012-01-25 07:45, 2011-09-12 08:18, 2011-09-02 11:10, 2011-06-21 09:30, 2011-05-20 10:00, 2011-05-16 13:30
- Namespace
- meinberg
- Source file
MBG-SNMP-LTNG-MIB- Digest
sha256:ac810c05a529f0540e05f80928c1267c5d7ecd01708ee871423225c070ddd763
Description
Meinberg LANTIME SNMP Management Information Base
Contact
postal: Meinberg Funkuhren Lange Wand 9 31812 Bad Pyrmont Germany email: info@meinberg.de web: http://www.meinberg.de tel: +49 (0) 52 81 / 93 09 - 0 fax: +49 (0) 52 81 / 93 09 - 30
Imports
| From | Symbols |
|---|---|
| MBG-SNMP-ROOT-MIB | MeinbergSwitch, mbgSnmpRoot |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter64, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
MBG-SNMP-LTNG-MIB MBG-SNMP-ROOT-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| mbgLantimeNGStatus OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.0 | |||
| mbgLtNgInfo OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.0.0 | |||
| mbgLtNgSnmpSubagentVersion OBJECT-TYPE version of this SNMP subagent | 1.3.6.1.4.1.5597.30.0.0.1 | DisplayString | read-only | current |
| mbgLtNgFirmwareVersion OBJECT-TYPE installed LANTIME firmware version | 1.3.6.1.4.1.5597.30.0.0.2 | DisplayString | read-only | current |
| mbgLtNgSerialNumber OBJECT-TYPE LANTIME serial number | 1.3.6.1.4.1.5597.30.0.0.3 | DisplayString | read-only | current |
| mbgLtNgSubagentTimeticks OBJECT-TYPE Subdaemons' time alive in seconds | 1.3.6.1.4.1.5597.30.0.0.4 | Counter64 | read-only | current |
| mbgLtNgCpuSerialNumber OBJECT-TYPE CPU's serial number | 1.3.6.1.4.1.5597.30.0.0.5 | DisplayString | read-only | current |
| mbgLtNgRefclock OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.0.1 | |||
| mbgLtNgNumberOfRefclocks OBJECT-TYPE currently installed number of refclocks | 1.3.6.1.4.1.5597.30.0.1.1 | Unsigned32 (0..2) | read-only | current |
| mbgLtNgRefclockTable OBJECT-TYPE a table of refclock related variables | 1.3.6.1.4.1.5597.30.0.1.2 | not-accessible | current | |
| mbgLtNgRefclockTableEntry OBJECT-TYPE a list of objects pertaining to a refclock | 1.3.6.1.4.1.5597.30.0.1.2.1 | not-accessible | current | |
| mbgLtNgRefclockIndex OBJECT-TYPE index for refclock | 1.3.6.1.4.1.5597.30.0.1.2.1.1 | Unsigned32 (1..2) | not-accessible | current |
| mbgLtNgRefclockType OBJECT-TYPE type of refclock | 1.3.6.1.4.1.5597.30.0.1.2.1.2 | INTEGER {unknown(0), gps166(1), gps167(2), gps167SV(3), gps167PC(4), gps167PCI(5), gps163(6), gps168PCI(7), gps161(8), gps169PCI(9), tcr167PCI(10), gps164(11), gps170PCI(12), pzf511(13), gps170(14), tcr511(15), am511(16), msf511(17), grc170(18), gps170PEX(19), gps162(20), ptp270PEX(21), frc511PEX(22), gen170(23), tcr170PEX(24), wwvb511(25), mgr170(26), jjy511(27), pzf600(28), tcr600(29), gps180(30), gln170(31), gps180PEX(32), tcr180PEX(33), pzf180PEX(34), mgr180(35), msf600(36), wwvb600(37), jjy600(38), gps180HS(39), gps180AMC(40), esi180(41), cpe180(42), lno180(43), grc180(44), liu(45), dcf600HS(46), dcf600RS(47), mri(48), bpe(49), gln180Pex(50), n2x(51), rsc180(52), lneGb(53), lnePpg180(54), scg(55), mdu300(56), sdi(57), fdm180(58), spt(59), pzf180(60), rel1000(61)} | read-only | current |
| mbgLtNgRefclockUsage OBJECT-TYPE what this refclock is used for | 1.3.6.1.4.1.5597.30.0.1.2.1.3 | INTEGER {notAvailable(0), secondary(1), compare(2), primary(3)} | read-only | current |
| mbgLtNgRefclockState OBJECT-TYPE state of GPS refclock conneted to NTP time server as value 0: not available 1: synchronized 2: not synchronized | 1.3.6.1.4.1.5597.30.0.1.2.1.4 | INTEGER {notAvailable(0), synchronized(1), notSynchronized(2)} | read-only | current |
| mbgLtNgRefclockSubstate OBJECT-TYPE more detailed state depending on refclock type 0: no substate available gps: 1-4 long waves (PZF,WWVB,MSF,...): 50-52 (not supported by all types) irig: 100-101 | 1.3.6.1.4.1.5597.30.0.1.2.1.5 | INTEGER {mrsRefNone(-1), notAvailable(0), gpsSync(1), gpsTracking(2), gpsAntennaDisconnected(3), gpsWarmBoot(4), gpsColdBoot(5), gpsAntennaShortCircuit(6), lwNeverSync(50), lwNotSync(51), lwSync(52), tcrNotSync(100), tcrSync(101), mrsGpsSync(150), mrs10MhzSync(151), mrsPpsInSync(152), mrs10MhzPpsInSync(153), mrsIrigSync(154), mrsNtpSync(155), mrsPtpIeee1588Sync(156), mrsPtpOverE1Sync(157), mrsFixedFreqInSync(158), mrsPpsStringSync(159), mrsVarFreqGpioSync(160), mrsReserved(161), mrsDcf77PzfSync(162), mrsLongwaveSync(163), mrsGlonassGpsSync(164), mrsHavequickSync(165), mrsExtOscSync(166), mrsIntOscSync(167)} | read-only | current |
| mbgLtNgRefclockStatusA OBJECT-TYPE status A depending on reflcock gps : indicates number of good satellites in view long wave - pzf : correlation - other : not supported irig : not supported | 1.3.6.1.4.1.5597.30.0.1.2.1.6 | Unsigned32 (0..100) | read-only | current |
| mbgLtNgRefclockMaxStatusA OBJECT-TYPE maximum status A depending on reflcock gps : indicates number of satellites in view long wave - pzf : 100 - other : not supported irig : not supported | 1.3.6.1.4.1.5597.30.0.1.2.1.7 | Unsigned32 (0..100) | read-only | current |
| mbgLtNgRefclockStatusB OBJECT-TYPE maximum status B depending on reflcock gps : not supported long wave - all : field strength irig : not supported | 1.3.6.1.4.1.5597.30.0.1.2.1.8 | Unsigned32 (0..100) | read-only | current |
| mbgLtNgRefclockMaxStatusB OBJECT-TYPE maximum status B depending on reflcock gps : not supported long wave - all : 100 irig : not supported | 1.3.6.1.4.1.5597.30.0.1.2.1.9 | Unsigned32 (0..100) | read-only | current |
| mbgLtNgRefclockAdditionalInfo OBJECT-TYPE any kind of additional information concerning a refclock | 1.3.6.1.4.1.5597.30.0.1.2.1.10 | INTEGER {notAvailable(0), leapSecondAnnounced(1)} | read-only | current |
| mbgLtNgRefclockLeapSecondDate OBJECT-TYPE Date for next leap second | 1.3.6.1.4.1.5597.30.0.1.2.1.11 | DisplayString | read-only | current |
| mbgLtNgRefclockGpsTable OBJECT-TYPE a table of gps only related variables | 1.3.6.1.4.1.5597.30.0.1.3 | not-accessible | current | |
| mbgLtNgRefclockGpsTableEntry OBJECT-TYPE a list of objects pertaining to a GPS refclock | 1.3.6.1.4.1.5597.30.0.1.3.1 | not-accessible | current | |
| mbgLtNgRefclockGpsIndex OBJECT-TYPE index for GPS | 1.3.6.1.4.1.5597.30.0.1.3.1.1 | Unsigned32 | not-accessible | current |
| mbgLtNgRefclockGpsLatitude OBJECT-TYPE GPS' latitude | 1.3.6.1.4.1.5597.30.0.1.3.1.2 | DisplayString | read-only | current |
| mbgLtNgRefclockGpsLongitude OBJECT-TYPE GPS' longitude | 1.3.6.1.4.1.5597.30.0.1.3.1.3 | DisplayString | read-only | current |
| mbgLtNgRefclockGpsAltitude OBJECT-TYPE GPS' altitude | 1.3.6.1.4.1.5597.30.0.1.3.1.4 | Integer32 | read-only | current |
| mbgLtNgRefclockGpsTdop OBJECT-TYPE GPS' timing dillution of precision | 1.3.6.1.4.1.5597.30.0.1.3.1.5 | DisplayString | read-only | current |
| mbgLtNgRefclockGpsPdop OBJECT-TYPE GPS' positional dillution of precision | 1.3.6.1.4.1.5597.30.0.1.3.1.6 | DisplayString | read-only | current |
| mbgLtNgRefclockGpsUtcOffset OBJECT-TYPE GPS' offset to UTC in seconds | 1.3.6.1.4.1.5597.30.0.1.3.1.7 | Integer32 | read-only | current |
| mbgLtNgRefclockTimeDiff OBJECT-TYPE when there is more than one refclock this object shows the internal time difference in milliseconds | 1.3.6.1.4.1.5597.30.0.1.4 | Integer32 | read-only | current |
| mbgLtNgRefclockGpsPos OBJECT-TYPE shows current GPS receiver position | 1.3.6.1.4.1.5597.30.0.1.5 | DisplayString | read-only | current |
| mbgLtNgNtp OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.0.2 | |||
| mbgLtNgNtpCurrentState OBJECT-TYPE Current NTP's synchronization status | 1.3.6.1.4.1.5597.30.0.2.1 | INTEGER {notAvailable(0), notSynchronized(1), synchronized(2)} | read-only | current |
| mbgLtNgNtpStratum OBJECT-TYPE Stratum value of the NTP | 1.3.6.1.4.1.5597.30.0.2.2 | Integer32 (0..16) | read-only | current |
| mbgLtNgNtpRefclockName OBJECT-TYPE Name of the current refclock selected by the NTP | 1.3.6.1.4.1.5597.30.0.2.3 | DisplayString | read-only | current |
| mbgLtNgNtpRefclockOffset OBJECT-TYPE Time offset between the current selected refclock and time of NTP as string in milliseconds | 1.3.6.1.4.1.5597.30.0.2.4 | DisplayString | read-only | current |
| mbgLtNgNtpVersion OBJECT-TYPE integrated NTP version | 1.3.6.1.4.1.5597.30.0.2.5 | DisplayString | read-only | current |
| mbgLtNgNtpClientCounter OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.0.2.8 | |||
| mbgLtNgNtpCCStartedAt OBJECT-TYPE start time of current NTP client counter session as timestamp | 1.3.6.1.4.1.5597.30.0.2.8.1 | Counter64 | read-only | current |
| mbgLtNgNtpCCDuration OBJECT-TYPE total duration of NTP client counter in seconds | 1.3.6.1.4.1.5597.30.0.2.8.2 | Unsigned32 | read-only | current |
| mbgLtNgNtpCCNumberOfClients OBJECT-TYPE total number of different clients requesting time | 1.3.6.1.4.1.5597.30.0.2.8.3 | Unsigned32 | read-only | current |
| mbgLtNgNtpCCTotalRequests OBJECT-TYPE total requests since starting the daemon | 1.3.6.1.4.1.5597.30.0.2.8.4 | Counter64 | read-only | current |
| mbgLtNgNtpCCTotalRequestsCurrentDay OBJECT-TYPE today's total requests | 1.3.6.1.4.1.5597.30.0.2.8.5 | Counter64 | read-only | current |
| mbgLtNgNtpCCTotalRequestsLastHour OBJECT-TYPE today's requests within the last completed hour | 1.3.6.1.4.1.5597.30.0.2.8.6 | Counter64 | read-only | current |
| mbgLtNgNtpCCTotalRequestsLastMinute OBJECT-TYPE today's requests within the last completed minute | 1.3.6.1.4.1.5597.30.0.2.8.7 | Counter64 | read-only | current |
| mbgLtNgNtpCCTodaysClients OBJECT-TYPE today's number of different clients requesting time | 1.3.6.1.4.1.5597.30.0.2.8.8 | Unsigned32 | read-only | current |
| mbgLtNgNtpMrs OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.0.2.9 | |||
| mbgLtNgNtpMrsServer OBJECT-TYPE external NTP server being used for synchronization | 1.3.6.1.4.1.5597.30.0.2.9.1 | DisplayString | read-only | current |
| mbgLtNgNtpMrsOffset OBJECT-TYPE external NTP server's offset | 1.3.6.1.4.1.5597.30.0.2.9.2 | DisplayString | read-only | current |
| mbgLtNgPtp OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.0.3 | |||
| mbgLtNgPtpNumberOfModules OBJECT-TYPE number of available PTPv2 modules | 1.3.6.1.4.1.5597.30.0.3.1 | Unsigned32 | read-only | current |
| mbgLtNgPtpTable OBJECT-TYPE a table of PTPv2 related variables | 1.3.6.1.4.1.5597.30.0.3.2 | not-accessible | current | |
| mbgLtNgPtpTableEntry OBJECT-TYPE a list of objects pertaining to a PTPv2 module | 1.3.6.1.4.1.5597.30.0.3.2.1 | not-accessible | current | |
| mbgLtNgPtpIndex OBJECT-TYPE index for PTPv2 module | 1.3.6.1.4.1.5597.30.0.3.2.1.1 | Unsigned32 | not-accessible | current |
| mbgLtNgPtpMode OBJECT-TYPE PTPv2 modus as integer. This object is obsolete and always returns '0'. Please see alternates mbgLtNgPtpPortState and mbgLtNgPtpRole. | 1.3.6.1.4.1.5597.30.0.3.2.1.2 | INTEGER {notAvailable(0), stopped(1), master(2), slave(3), ordinary(4)} | read-only | obsolete |
| mbgLtNgPtpPortState OBJECT-TYPE port state as integer | 1.3.6.1.4.1.5597.30.0.3.2.1.3 | INTEGER {uninitialized(0), initializing(1), faulty(2), disabled(3), listening(4), preMaster(5), master(6), passive(7), uncalibrated(8), slave(9)} | read-only | current |
| mbgLtNgPtpGrandmasterMac OBJECT-TYPE MAC address of current grandmaster | 1.3.6.1.4.1.5597.30.0.3.2.1.4 | DisplayString | read-only | current |
| mbgLtNgPtpClockAccuracy OBJECT-TYPE indicates the source of time | 1.3.6.1.4.1.5597.30.0.3.2.1.5 | INTEGER {notAvailable(0), timeAccurateTo25ns(32), timeAccurateTo100ns(33), timeAccurateTo250ns(34), timeAccurateTo1us(35), timeAccurateTo2Point5us(36), timeAccurateTo10us(37), timeAccurateTo25us(38), timeAccurateTo100us(39), timeAccurateTo250us(40), timeAccurateTo1ms(41), timeAccurateTo2to5ms(42), timeAccurateTo10ms(43), timeAccurateTo25ms(44), timeAccurateTo100ms(45), timeAccurateTo250ms(46), timeAccurateTo1s(47), timeAccurateTo10s(48), timeAccurateToGT10s(49), timeAccurateToUnknown(254)} | read-only | current |
| mbgLtNgPtpClockClass OBJECT-TYPE denotes the traceability of the time or frequency | 1.3.6.1.4.1.5597.30.0.3.2.1.6 | Unsigned32 (0..255) | read-only | current |
| mbgLtNgPtpTimeSource OBJECT-TYPE source of time being used | 1.3.6.1.4.1.5597.30.0.3.2.1.7 | INTEGER {notAvailable(0), atomicClock(16), gps(32), terrestrialRadio(48), ptp(64), ntp(80), handSet(96), other(144), internalOscillator(160)} | read-only | current |
| mbgLtNgPtpUtcOffset OBJECT-TYPE offset from PTP's TAI time to UTC time | 1.3.6.1.4.1.5597.30.0.3.2.1.8 | Unsigned32 | read-only | current |
| mbgLtNgPtpTimeSeconds OBJECT-TYPE PTP seconds | 1.3.6.1.4.1.5597.30.0.3.2.1.9 | Counter64 | read-only | current |
| mbgLtNgPtpTsuTime OBJECT-TYPE current time on PTP TSU | 1.3.6.1.4.1.5597.30.0.3.2.1.10 | DisplayString | read-only | current |
| mbgLtNgPtpSysTime OBJECT-TYPE current system time | 1.3.6.1.4.1.5597.30.0.3.2.1.11 | DisplayString | read-only | current |
| mbgLtNgPtpPortLinkup OBJECT-TYPE PTP port's physical link-up | 1.3.6.1.4.1.5597.30.0.3.2.1.12 | MeinbergSwitch | read-only | current |
| mbgLtNgPtpOffsetFromGM OBJECT-TYPE offset from grandmaster in nanoseconds | 1.3.6.1.4.1.5597.30.0.3.2.1.13 | DisplayString | read-only | current |
| mbgLtNgPtpPathDelay OBJECT-TYPE network delay in nanoseconds | 1.3.6.1.4.1.5597.30.0.3.2.1.14 | DisplayString | read-only | current |
| mbgLtNgPtpDelayMec OBJECT-TYPE delay mechanism | 1.3.6.1.4.1.5597.30.0.3.2.1.15 | INTEGER {end2End(0), peer2Peer(1)} | read-only | current |
| mbgLtNgPtpDomain OBJECT-TYPE domain number | 1.3.6.1.4.1.5597.30.0.3.2.1.16 | Unsigned32 (0..255) | read-only | current |
| mbgLtNgPtpGrandmasterUuid OBJECT-TYPE grandmaster uuid | 1.3.6.1.4.1.5597.30.0.3.2.1.17 | DisplayString | read-only | current |
| mbgLtNgPtpLocalMac OBJECT-TYPE local MAC address | 1.3.6.1.4.1.5597.30.0.3.2.1.18 | DisplayString | read-only | current |
| mbgLtNgPtpDelayAsymmetry OBJECT-TYPE asymmetric network delay in nanoseconds | 1.3.6.1.4.1.5597.30.0.3.2.1.19 | DisplayString | read-only | current |
| mbgLtNgPtpAvail OBJECT-TYPE Signals whether PTP instance is avail or not | 1.3.6.1.4.1.5597.30.0.3.2.1.20 | INTEGER {no(0), yes(1)} | read-only | current |
| mbgLtNgFdm OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.0.4 | |||
| mbgLtNgFdmFreq OBJECT-TYPE powerline frequency in mHz; 0 indicates that no data is available | 1.3.6.1.4.1.5597.30.0.4.1 | Unsigned32 (0 | 45000..65000) | read-only | current |
| mbgLtNgFdmFreqDev OBJECT-TYPE frequency deviation in mHz depending on the configured nominal frequency; check 'mbgLtNgFdmFreq' for error | 1.3.6.1.4.1.5597.30.0.4.2 | Integer32 (-15000..15000) | read-only | current |
| mbgLtNgFdmNomFreq OBJECT-TYPE nominal frequency in mHz; can be 50000 (50Hz) or 60000 (60Hz); 0 indicates that no value is configured | 1.3.6.1.4.1.5597.30.0.4.3 | Unsigned32 (0 | 50000 | 60000) | read-only | current |
| mbgLtNgSystemHardware OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.0.5 | |||
| mbgLtNgSysPowerSupply OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.0.5.0 | |||
| mbgLtNgSysNumberOfPowerSupplies OBJECT-TYPE number of available power supplies | 1.3.6.1.4.1.5597.30.0.5.0.1 | Unsigned32 | read-only | current |
| mbgLtNgSysPsTable OBJECT-TYPE a table of power supply stati | 1.3.6.1.4.1.5597.30.0.5.0.2 | not-accessible | current | |
| mbgLtNgSysPsTableEntry OBJECT-TYPE a list of objects pertaining to power supplies | 1.3.6.1.4.1.5597.30.0.5.0.2.1 | not-accessible | current | |
| mbgLtNgSysPsIndex OBJECT-TYPE index of power supply | 1.3.6.1.4.1.5597.30.0.5.0.2.1.1 | Unsigned32 | not-accessible | current |
| mbgLtNgSysPsStatus OBJECT-TYPE Status of power supply | 1.3.6.1.4.1.5597.30.0.5.0.2.1.2 | INTEGER {notAvailable(0), down(1), up(2)} | read-only | current |
| mbgLtNgSysFan OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.0.5.1 | |||
| mbgLtNgSysNumberOfFans OBJECT-TYPE number of available fans | 1.3.6.1.4.1.5597.30.0.5.1.1 | Unsigned32 | read-only | current |
| mbgLtNgSysFanTable OBJECT-TYPE a table of power supply stati | 1.3.6.1.4.1.5597.30.0.5.1.2 | not-accessible | current | |
| mbgLtNgSysFanTableEntry OBJECT-TYPE a list of objects pertaining to fans | 1.3.6.1.4.1.5597.30.0.5.1.2.1 | not-accessible | current | |
| mbgLtNgSysFanIndex OBJECT-TYPE index of fan | 1.3.6.1.4.1.5597.30.0.5.1.2.1.1 | Unsigned32 | not-accessible | current |
| mbgLtNgSysFanStatus OBJECT-TYPE Status of fan | 1.3.6.1.4.1.5597.30.0.5.1.2.1.2 | INTEGER {notAvailable(0), off(1), on(2)} | read-only | current |
| mbgLtNgSysFanError OBJECT-TYPE fan's error field | 1.3.6.1.4.1.5597.30.0.5.1.2.1.3 | INTEGER {notAvailable(0), no(1), yes(2)} | read-only | current |
| mbgLtNgSysTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.0.5.2 | |||
| mbgLtNgSysTempCelsius OBJECT-TYPE temperature in degree Celsius | 1.3.6.1.4.1.5597.30.0.5.2.1 | Unsigned32 | read-only | current |
| mbgLtNgCluster OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.0.6 | |||
| mbgLtNgNumberOfClusters OBJECT-TYPE number of active running clusters | 1.3.6.1.4.1.5597.30.0.6.1 | Unsigned32 | read-only | current |
| mbgLtNgClusterTable OBJECT-TYPE a table of cluster status information | 1.3.6.1.4.1.5597.30.0.6.2 | not-accessible | current | |
| mbgLtNgClusterTableEntry OBJECT-TYPE a list of objects pertaining to running and active clusters | 1.3.6.1.4.1.5597.30.0.6.2.1 | not-accessible | current | |
| mbgLtNgClusterIndex OBJECT-TYPE index of power supply | 1.3.6.1.4.1.5597.30.0.6.2.1.1 | Unsigned32 | not-accessible | current |
| mbgLtNgClusterCommunicationIp OBJECT-TYPE ip of cluster interface | 1.3.6.1.4.1.5597.30.0.6.2.1.2 | DisplayString | read-only | current |
| mbgLtNgClusterPortState OBJECT-TYPE state of cluster | 1.3.6.1.4.1.5597.30.0.6.2.1.3 | INTEGER {notAvailable(0), master(1), slave(2), listening(3)} | read-only | current |
| mbgLtNgClusterMasterSerial OBJECT-TYPE serial number of cluster's master | 1.3.6.1.4.1.5597.30.0.6.2.1.4 | DisplayString | read-only | current |
| mbgLtNgClusterMasterIp OBJECT-TYPE ip address of cluster's master | 1.3.6.1.4.1.5597.30.0.6.2.1.5 | DisplayString | read-only | current |
| mbgLtNgClusterMasterPriority OBJECT-TYPE priority of cluster master | 1.3.6.1.4.1.5597.30.0.6.2.1.6 | Unsigned32 | read-only | current |
| mbgLtNgClusterClockClass OBJECT-TYPE reference's clock class | 1.3.6.1.4.1.5597.30.0.6.2.1.7 | INTEGER {notAvailable(0), gps(3), pzf(4), am(5), irig(6), pps(7), ptp(8), ntp(9), e1(10), rdt(11)} | read-only | current |
| mbgLtNgClusterClockStatus OBJECT-TYPE reference's clock status | 1.3.6.1.4.1.5597.30.0.6.2.1.8 | INTEGER {notAvailable(0), normalOperation(1), freeRunningOrTracking(2), antennaFailure(3), invalid(4)} | read-only | current |
| mbgLtNgClusterReconfigurationState OBJECT-TYPE current reconfiguration state | 1.3.6.1.4.1.5597.30.0.6.2.1.9 | INTEGER {notAvailable(0), normal(1), masterToSlave(2), slaveToMaster(3)} | read-only | current |
| mbgLtNgClusterIsFalseticker OBJECT-TYPE am I a falseticker? | 1.3.6.1.4.1.5597.30.0.6.2.1.10 | INTEGER {notAvailable(0), no(1), yes(2)} | read-only | current |
| mbgLtNgMisc OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.0.7 | |||
| mbgLtNgEthPortLinkTable OBJECT-TYPE a table of physical ethernet interface port link states | 1.3.6.1.4.1.5597.30.0.7.1 | not-accessible | current | |
| mbgLtNgEthPortLinkTableEntry OBJECT-TYPE port link states for each physical ethernet interface | 1.3.6.1.4.1.5597.30.0.7.1.1 | not-accessible | current | |
| mbgLtNgEthPortLinkIndex OBJECT-TYPE interface index | 1.3.6.1.4.1.5597.30.0.7.1.1.1 | Unsigned32 | not-accessible | current |
| mbgLtNgEthPortLinkState OBJECT-TYPE link state | 1.3.6.1.4.1.5597.30.0.7.1.1.2 | INTEGER {down(0), up(1)} | read-only | current |
| mbgLtNgConfig OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1 | |||
| mbgLtNgCfgEthernet OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.0 | |||
| mbgLtNgCfgEthernetHostname OBJECT-TYPE devices' hostname | 1.3.6.1.4.1.5597.30.1.0.1 | DisplayString | read-write | current |
| mbgLtNgCfgEthernetDomain OBJECT-TYPE devices' domain membership | 1.3.6.1.4.1.5597.30.1.0.2 | DisplayString | read-write | current |
| mbgLtNgCfgEthernetNameserver1 OBJECT-TYPE first nameserver's ip address | 1.3.6.1.4.1.5597.30.1.0.3 | DisplayString | read-write | current |
| mbgLtNgCfgEthernetNameserver2 OBJECT-TYPE second nameserver's ip address | 1.3.6.1.4.1.5597.30.1.0.4 | DisplayString | read-write | current |
| mbgLtNgCfgEthernetIpv4Gateway OBJECT-TYPE device's ethernet ipv4 gateway | 1.3.6.1.4.1.5597.30.1.0.5 | DisplayString | read-write | current |
| mbgLtNgCfgEthernetIpv6Gateway OBJECT-TYPE device's ethernet ipv6 gateway | 1.3.6.1.4.1.5597.30.1.0.6 | DisplayString | read-write | current |
| mbgLtNgCfgNumberOfPhysicalIf OBJECT-TYPE number of virtual interfaces interfaces | 1.3.6.1.4.1.5597.30.1.0.7 | Unsigned32 | read-only | current |
| mbgLtNgCfgNumberOfVirtualIf OBJECT-TYPE number of virtual interfaces interfaces | 1.3.6.1.4.1.5597.30.1.0.8 | Unsigned32 | read-only | current |
| mbgLtNgCfgPhysicalIfTable OBJECT-TYPE a table of service stati for the ethernet interfaces | 1.3.6.1.4.1.5597.30.1.0.9 | not-accessible | current | |
| mbgLtNgCfgPhysicalIfTableEntry OBJECT-TYPE a list of objects pertaining to a mrs input reference | 1.3.6.1.4.1.5597.30.1.0.9.1 | not-accessible | current | |
| mbgLtNgCfgPhysicalIfIndex OBJECT-TYPE specifies the physical interface index | 1.3.6.1.4.1.5597.30.1.0.9.1.1 | Unsigned32 | not-accessible | current |
| mbgLtNgCfgPhysicalIfMac OBJECT-TYPE interface's physical MAC address | 1.3.6.1.4.1.5597.30.1.0.9.1.2 | DisplayString | read-only | current |
| mbgLtNgCfgPhysicalIfNetLinkMode OBJECT-TYPE interface's net link mode; hd = half-duplex; fd = full-duplex | 1.3.6.1.4.1.5597.30.1.0.9.1.3 | INTEGER {auto(0), hd10Mbit(1), fd10Mbit(2), hd100Mbit(3), fd100Mbit(4), hd1000Mbit(5), fd1000Mbit(6)} | read-write | current |
| mbgLtNgCfgPhysicalIfIndicateLink OBJECT-TYPE indicate link via front panel LED | 1.3.6.1.4.1.5597.30.1.0.9.1.4 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgPhysicalIfBondingGroup OBJECT-TYPE assign interface to bonding group; '0' means not assigned | 1.3.6.1.4.1.5597.30.1.0.9.1.5 | Unsigned32 (0..5) | read-write | current |
| mbgLtNgCfgPhysicalIfIpv6Mode OBJECT-TYPE enable IPv6 mode | 1.3.6.1.4.1.5597.30.1.0.9.1.6 | INTEGER {deactivated(0), activated(1), activatedWithAutoconf(2)} | read-write | current |
| mbgLtNgCfgVirtualIfTable OBJECT-TYPE a table of service stati for the ethernet interfaces | 1.3.6.1.4.1.5597.30.1.0.10 | not-accessible | current | |
| mbgLtNgCfgVirtualIfTableEntry OBJECT-TYPE a list of objects pertaining to a mrs input reference | 1.3.6.1.4.1.5597.30.1.0.10.1 | not-accessible | current | |
| mbgLtNgCfgVirtualIfIndex OBJECT-TYPE specifies the virtual interface index | 1.3.6.1.4.1.5597.30.1.0.10.1.1 | Unsigned32 | not-accessible | current |
| mbgLtNgCfgVirtualIfIpv4Addr OBJECT-TYPE interfaces' ipv4 address | 1.3.6.1.4.1.5597.30.1.0.10.1.2 | DisplayString | read-write | current |
| mbgLtNgCfgVirtualIfIpv4Netmask OBJECT-TYPE interfaces' ipv4 netmask | 1.3.6.1.4.1.5597.30.1.0.10.1.3 | DisplayString | read-write | current |
| mbgLtNgCfgVirtualIfIpv4Dhcp OBJECT-TYPE interface uses ipv4 dhcp? | 1.3.6.1.4.1.5597.30.1.0.10.1.4 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgVirtualIfIpv4AddrFromDhcp OBJECT-TYPE interfaces' ipv4 address received from dhcp | 1.3.6.1.4.1.5597.30.1.0.10.1.5 | DisplayString | read-only | current |
| mbgLtNgCfgVirtualIfIpv4NetmaskFromDhcp OBJECT-TYPE interfaces' ipv4 netmask received from dhcp | 1.3.6.1.4.1.5597.30.1.0.10.1.6 | DisplayString | read-only | current |
| mbgLtNgCfgVirtualIfIpv4BroadcastFromDhcp OBJECT-TYPE interfaces' ipv4 broadcast received from dhcp | 1.3.6.1.4.1.5597.30.1.0.10.1.7 | DisplayString | read-only | current |
| mbgLtNgCfgVirtualIfIpv4GatewayFromDhcp OBJECT-TYPE interfaces' ipv4 gateway received from dhcp | 1.3.6.1.4.1.5597.30.1.0.10.1.8 | DisplayString | read-only | current |
| mbgLtNgCfgVirtualIfIpv4DnsFromDhcp OBJECT-TYPE interfaces' ipv4 dns server received from dhcp | 1.3.6.1.4.1.5597.30.1.0.10.1.9 | DisplayString | read-only | current |
| mbgLtNgCfgVirtualIfIpv4DomainFromDhcp OBJECT-TYPE interfaces' ipv4 dns server received from dhcp | 1.3.6.1.4.1.5597.30.1.0.10.1.10 | DisplayString | read-only | current |
| mbgLtNgCfgVirtualIfIpv6Addr OBJECT-TYPE interfaces' ipv6 address | 1.3.6.1.4.1.5597.30.1.0.10.1.11 | DisplayString | read-write | current |
| mbgLtNgCfgVirtualIfIpv6Dhcp OBJECT-TYPE interfaces uses ipv6 dhcp | 1.3.6.1.4.1.5597.30.1.0.10.1.12 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgVirtualIfIpv6RoutAdd OBJECT-TYPE interfaces' router advertisement ipv6 address | 1.3.6.1.4.1.5597.30.1.0.10.1.13 | DisplayString | read-only | current |
| mbgLtNgCfgVirtualIfIpv6LinkLocal OBJECT-TYPE interfaces' ipv6 link local address | 1.3.6.1.4.1.5597.30.1.0.10.1.14 | DisplayString | read-only | current |
| mbgLtNgCfgVirtualIfAssigned OBJECT-TYPE mapping to the physical interface this virtual one is assigned to | 1.3.6.1.4.1.5597.30.1.0.10.1.15 | Unsigned32 | read-write | current |
| mbgLtNgCfgVirtualIfMac OBJECT-TYPE MAC-address of this virtual interface | 1.3.6.1.4.1.5597.30.1.0.10.1.16 | DisplayString | read-only | current |
| mbgLtNgCfgVirtualIfLabel OBJECT-TYPE user description for this label (like an alias) | 1.3.6.1.4.1.5597.30.1.0.10.1.17 | DisplayString | read-write | current |
| mbgLtNgCfgVirtualIfVlan OBJECT-TYPE is vlan enabled | 1.3.6.1.4.1.5597.30.1.0.10.1.18 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgVirtualIfVlanTag OBJECT-TYPE vlan tag | 1.3.6.1.4.1.5597.30.1.0.10.1.19 | Unsigned32 (0..4094) | read-write | current |
| mbgLtNgCfgVirtualIfVlanPrio OBJECT-TYPE vlan priority | 1.3.6.1.4.1.5597.30.1.0.10.1.20 | Unsigned32 (0..7) | read-write | current |
| mbgLtNgCfgVirtualIfCluster OBJECT-TYPE is cluster mode enabled | 1.3.6.1.4.1.5597.30.1.0.10.1.21 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgVirtualIfClusterIpv4Addr OBJECT-TYPE ipv4 cluster address | 1.3.6.1.4.1.5597.30.1.0.10.1.22 | DisplayString | read-write | current |
| mbgLtNgCfgVirtualIfClusterIpv4Netmask OBJECT-TYPE cluster ipv4 netmask | 1.3.6.1.4.1.5597.30.1.0.10.1.23 | DisplayString | read-write | current |
| mbgLtNgCfgVirtualIfClusterPrio OBJECT-TYPE cluster priority | 1.3.6.1.4.1.5597.30.1.0.10.1.24 | Unsigned32 (0..10) | read-write | current |
| mbgLtNgCfgVirtualIfServiceNtp OBJECT-TYPE is ntp active on this interface | 1.3.6.1.4.1.5597.30.1.0.10.1.25 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgVirtualIfServiceHttp OBJECT-TYPE is http active on this interface | 1.3.6.1.4.1.5597.30.1.0.10.1.26 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgVirtualIfServiceHttps OBJECT-TYPE is https active on this interface | 1.3.6.1.4.1.5597.30.1.0.10.1.27 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgVirtualIfServiceTelnet OBJECT-TYPE is telnet active on this interface | 1.3.6.1.4.1.5597.30.1.0.10.1.28 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgVirtualIfServiceSsh OBJECT-TYPE is ssh active on this interface | 1.3.6.1.4.1.5597.30.1.0.10.1.29 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgVirtualIfServiceSnmp OBJECT-TYPE is snmp active on this interface | 1.3.6.1.4.1.5597.30.1.0.10.1.30 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgVirtualIfServiceFtp OBJECT-TYPE is ftp active on this interface | 1.3.6.1.4.1.5597.30.1.0.10.1.31 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgVirtualIfServiceTime OBJECT-TYPE is time active on this interface | 1.3.6.1.4.1.5597.30.1.0.10.1.32 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgVirtualIfServiceDaytime OBJECT-TYPE is daytime active on this interface | 1.3.6.1.4.1.5597.30.1.0.10.1.33 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgVirtualIfServiceFpc OBJECT-TYPE is fpc active on this interface | 1.3.6.1.4.1.5597.30.1.0.10.1.34 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgEthernetGenClusterPort OBJECT-TYPE general cluster port | 1.3.6.1.4.1.5597.30.1.0.11 | Unsigned32 (0..65535) | read-write | current |
| mbgLtNgCfgEthernetGenClusterIp OBJECT-TYPE general multicast cluster address | 1.3.6.1.4.1.5597.30.1.0.12 | DisplayString | read-write | current |
| mbgLtNgCfgNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.1 | |||
| mbgLtNgCfgSyslog OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.1.0 | |||
| mbgLtNgCfgSyslogServerAddr OBJECT-TYPE comma separated string of all configured syslog servers; use such a list to set syslog servers | 1.3.6.1.4.1.5597.30.1.1.0.1 | DisplayString | read-write | current |
| mbgLtNgCfgSyslogLoglevel OBJECT-TYPE loglevel for syslog server | 1.3.6.1.4.1.5597.30.1.1.0.2 | INTEGER {emergency(0), alert(1), critical(2), error(3), warning(4), notice(5), info(6)} | read-write | current |
| mbgLtNgCfgEmail OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.1.1 | |||
| mbgLtNgCfgEmailTo OBJECT-TYPE email address to send alerts etc. to (receiving address) | 1.3.6.1.4.1.5597.30.1.1.1.1 | DisplayString | read-write | current |
| mbgLtNgCfgEmailFrom OBJECT-TYPE email address to send alerts etc. from (sending address) | 1.3.6.1.4.1.5597.30.1.1.1.2 | DisplayString | read-write | current |
| mbgLtNgCfgEmailSmarthostAddr OBJECT-TYPE SMTP smarthost used to send mail (ip or hostname) | 1.3.6.1.4.1.5597.30.1.1.1.3 | DisplayString | read-write | current |
| mbgLtNgCfgEmailSmarthostPort OBJECT-TYPE SMTP smarthost listenning port | 1.3.6.1.4.1.5597.30.1.1.1.4 | Unsigned32 (0..65535) | read-write | current |
| mbgLtNgCfgEmailSmarthostAuth OBJECT-TYPE use authentication for smarthost | 1.3.6.1.4.1.5597.30.1.1.1.5 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgEmailSmarthostAuthUser OBJECT-TYPE user to authenticate at smarthost | 1.3.6.1.4.1.5597.30.1.1.1.6 | DisplayString | read-write | current |
| mbgLtNgCfgEmailSmarthostAuthPw OBJECT-TYPE password to authenticate user at smarthost | 1.3.6.1.4.1.5597.30.1.1.1.7 | DisplayString | read-write | current |
| mbgLtNgCfgWinpopup OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.1.2 | |||
| mbgLtNgCfgWmailAddress1 OBJECT-TYPE first windows popup alert receiver (ip or hostname) | 1.3.6.1.4.1.5597.30.1.1.2.1 | DisplayString | read-write | current |
| mbgLtNgCfgWmailAddress2 OBJECT-TYPE second windows popup alert receiver (ip or hostname) | 1.3.6.1.4.1.5597.30.1.1.2.2 | DisplayString | read-write | current |
| mbgLtNgCfgSNMP OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.1.3 | |||
| mbgLtNgCfgSnmpTrapRecTable OBJECT-TYPE a table of SNMP trap receiver information | 1.3.6.1.4.1.5597.30.1.1.3.1 | not-accessible | current | |
| mbgLtNgCfgSnmpTrapRecTableEntry OBJECT-TYPE a list of objects pertaining to an interface and concerning broad-, multi- and manycast | 1.3.6.1.4.1.5597.30.1.1.3.1.1 | not-accessible | current | |
| mbgLtNgCfgSnmpTrapRecIndex OBJECT-TYPE index of different SNMP trap receivers | 1.3.6.1.4.1.5597.30.1.1.3.1.1.1 | Unsigned32 (0..4) | not-accessible | current |
| mbgLtNgCfgSnmpTrapRecAddr OBJECT-TYPE SNMP trap receiver address (ip or hostname) | 1.3.6.1.4.1.5597.30.1.1.3.1.1.2 | DisplayString | read-write | current |
| mbgLtNgCfgSnmpTrapRecCommunity OBJECT-TYPE SNMP trap receiver community | 1.3.6.1.4.1.5597.30.1.1.3.1.1.3 | DisplayString | read-write | current |
| mbgLtNgCfgSnmpTrapRecVersion OBJECT-TYPE SNMP trap receiver version | 1.3.6.1.4.1.5597.30.1.1.3.1.1.4 | INTEGER {v1(1), v2c(2), v3(3)} | read-write | current |
| mbgLtNgCfgSnmpReadCommunity OBJECT-TYPE read community for SNMPv1 and SNMPv2c | 1.3.6.1.4.1.5597.30.1.1.3.2 | DisplayString | read-write | current |
| mbgLtNgCfgSnmpWriteCommunity OBJECT-TYPE read community for SNMPv1 and SNMPv2c | 1.3.6.1.4.1.5597.30.1.1.3.3 | DisplayString | read-write | current |
| mbgLtNgCfgSnmpContact OBJECT-TYPE SNMP contact string for Lantime | 1.3.6.1.4.1.5597.30.1.1.3.4 | DisplayString | read-write | current |
| mbgLtNgCfgSnmpLocation OBJECT-TYPE SNMP location string for Lantime | 1.3.6.1.4.1.5597.30.1.1.3.5 | DisplayString | read-write | current |
| mbgLtNgCfgSnmpV3UserName OBJECT-TYPE username for SNMPv3 | 1.3.6.1.4.1.5597.30.1.1.3.6 | DisplayString | read-write | current |
| mbgLtNgCfgSnmpV3UserRights OBJECT-TYPE privacy protocol for SNMPv3 | 1.3.6.1.4.1.5597.30.1.1.3.7 | INTEGER {readonly(0), readwrite(1)} | read-write | current |
| mbgLtNgCfgSnmpV3Context OBJECT-TYPE context string for SNMPv3 | 1.3.6.1.4.1.5597.30.1.1.3.8 | DisplayString | read-write | current |
| mbgLtNgCfgSnmpV3SecurityLevel OBJECT-TYPE authentication level for SNMPv3 | 1.3.6.1.4.1.5597.30.1.1.3.9 | INTEGER {noAuthNoPriv(0), authNoPriv(1), authPriv(2)} | read-write | current |
| mbgLtNgCfgSnmpV3AuthProtocol OBJECT-TYPE authentication protocol for SNMPv3 | 1.3.6.1.4.1.5597.30.1.1.3.10 | INTEGER {md5(0), sha(1)} | read-write | current |
| mbgLtNgCfgSnmpV3AuthPassphrase OBJECT-TYPE authentication passphrase for SNMPv3 | 1.3.6.1.4.1.5597.30.1.1.3.11 | DisplayString | read-write | current |
| mbgLtNgCfgSnmpV3PrivProtocol OBJECT-TYPE privacy protocol for SNMPv3 | 1.3.6.1.4.1.5597.30.1.1.3.12 | INTEGER {des(0), aes(1)} | read-write | current |
| mbgLtNgCfgSnmpV3PrivPassphrase OBJECT-TYPE privacy passphrase for SNMPv3 | 1.3.6.1.4.1.5597.30.1.1.3.13 | DisplayString | read-write | current |
| mbgLtNgCfgSnmpRetries OBJECT-TYPE number of retries for sending traps | 1.3.6.1.4.1.5597.30.1.1.3.14 | Unsigned32 | read-write | current |
| mbgLtNgCfgSnmpTimeout OBJECT-TYPE timeout for sending traps (in seconds) | 1.3.6.1.4.1.5597.30.1.1.3.15 | Unsigned32 | read-write | current |
| mbgLtNgCfgSnmpEnabledVersion OBJECT-TYPE currently enabled SNMP version | 1.3.6.1.4.1.5597.30.1.1.3.16 | INTEGER {v1ANDv2c(0), v3only(1), v1ANDv2cANDv3(2)} | read-write | current |
| mbgLtNgCfgWalldisplay OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.1.4 | |||
| mbgLtNgCfgVP100Display1Addr OBJECT-TYPE address of wall display (ip or hostname) | 1.3.6.1.4.1.5597.30.1.1.4.1 | DisplayString | read-write | current |
| mbgLtNgCfgVP100Display1SN OBJECT-TYPE serial number of first VP100 wall display | 1.3.6.1.4.1.5597.30.1.1.4.2 | DisplayString | read-write | current |
| mbgLtNgCfgVP100Display2Addr OBJECT-TYPE address of wall display (ip or hostname) | 1.3.6.1.4.1.5597.30.1.1.4.3 | DisplayString | read-write | current |
| mbgLtNgCfgVP100Display2SN OBJECT-TYPE serial number of second VP100 wall display | 1.3.6.1.4.1.5597.30.1.1.4.4 | DisplayString | read-write | current |
| mbgLtNgCfgNtpClientMonitoring OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.1.5 | |||
| mbgLtNgCfgNtpMaxClientOffset OBJECT-TYPE max NTP client offset limit in milliseconds | 1.3.6.1.4.1.5597.30.1.1.5.1 | Unsigned32 | read-write | current |
| mbgLtNgCfgNtpMaxClientStratum OBJECT-TYPE max NTP client stratum level | 1.3.6.1.4.1.5597.30.1.1.5.2 | Unsigned32 (1..16) | read-write | current |
| mbgLtNgCfgTrapTrigger OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.1.6 | |||
| mbgLtNgCfgTrapNormalOperation OBJECT-TYPE string containing signaling information ( comma-separated ); use the following aliases to set params: Email -> email Wmail -> wmail Snmp -> snmp VP100 -> disp User -> own Alarm -> led Relay -> relais Following string is perfectly valid to enable signaling for SNMP and Email: 'snmp,email'. Please note that some objects do not suppurt relay and led but this is announced at each MIB object itself. This object, for example, does not support them. | 1.3.6.1.4.1.5597.30.1.1.6.1 | DisplayString | read-write | current |
| mbgLtNgCfgTrapNtpNotSync OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.2 | DisplayString | read-write | current |
| mbgLtNgCfgTrapNtpSync OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.3 | DisplayString | read-write | current |
| mbgLtNgCfgTrapNtpStopped OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.4 | DisplayString | read-write | current |
| mbgLtNgCfgTrapServerBoot OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.5 | DisplayString | read-write | current |
| mbgLtNgCfgTrapRefclockNotResponding OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.6 | DisplayString | read-write | current |
| mbgLtNgCfgTrapRefclockSynchronized OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.7 | DisplayString | read-write | current |
| mbgLtNgCfgTrapRefclockNotSynchronized OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.8 | DisplayString | read-write | current |
| mbgLtNgCfgTrapSecRefclockNotResponding OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.9 | DisplayString | read-write | current |
| mbgLtNgCfgTrapSecRefclockSynchronized OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.10 | DisplayString | read-write | current |
| mbgLtNgCfgTrapSecRefclockNotSynchronized OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.11 | DisplayString | read-write | current |
| mbgLtNgCfgTrapAntennaFaulty OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.12 | DisplayString | read-write | current |
| mbgLtNgCfgTrapAntennaReconnect OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.13 | DisplayString | read-write | current |
| mbgLtNgCfgTrapAntennaShortCircuit OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.14 | DisplayString | read-write | current |
| mbgLtNgCfgTrapConfigChanged OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.15 | DisplayString | read-write | current |
| mbgLtNgCfgTrapLeapSecAnnounced OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.16 | DisplayString | read-write | current |
| mbgLtNgCfgTrapNtpClientLimitExceeded OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.17 | DisplayString | read-write | current |
| mbgLtNgCfgTrapRefSrcLimitExceeded OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.18 | DisplayString | read-write | current |
| mbgLtNgCfgTrapRefSrcDisconnected OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.19 | DisplayString | read-write | current |
| mbgLtNgCfgTrapRefSrcReconnected OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.20 | DisplayString | read-write | current |
| mbgLtNgCfgTrapShsTimeLimitError OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.21 | DisplayString | read-write | current |
| mbgLtNgCfgTrapShsTimeLimitWarning OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.22 | DisplayString | read-write | current |
| mbgLtNgCfgTrapNetworkDown OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.23 | DisplayString | read-write | current |
| mbgLtNgCfgTrapNetworkUp OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.24 | DisplayString | read-write | current |
| mbgLtNgCfgTrapPowerSupplyUp OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.25 | DisplayString | read-write | current |
| mbgLtNgCfgTrapPowerSupplyDown OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.26 | DisplayString | read-write | current |
| mbgLtNgCfgTrapFdmError OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.27 | DisplayString | read-write | current |
| mbgLtNgCfgTrapLowSystemResources OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.28 | DisplayString | read-write | current |
| mbgLtNgCfgTrapPtpNetworkDown OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.29 | DisplayString | read-write | current |
| mbgLtNgCfgTrapPtpNetworkUp OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.30 | DisplayString | read-write | current |
| mbgLtNgCfgTrapPtpStateChanged OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.31 | DisplayString | read-write | current |
| mbgLtNgCfgTrapPtpError OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.32 | DisplayString | read-write | current |
| mbgLtNgCfgTrapFanDown OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.33 | DisplayString | read-write | current |
| mbgLtNgCfgTrapFanUp OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.34 | DisplayString | read-write | current |
| mbgLtNgCfgRepeatEvent OBJECT-TYPE when to send last error trap message again | 1.3.6.1.4.1.5597.30.1.1.6.35 | INTEGER {never(0), everyMinute(1), everyHour(2), everyDay(3)} | read-write | current |
| mbgLtNgCfgRepetitions OBJECT-TYPE how often do you want to resend an error trap | 1.3.6.1.4.1.5597.30.1.1.6.36 | Unsigned32 (0..50) | read-write | current |
| mbgLtNgCfgTrapWarmedUp OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.37 | DisplayString | read-write | current |
| mbgLtNgCfgTrapNotWarmedUp OBJECT-TYPE see 'mbgLtNgCfgTrapNormalOperation' for a detailed explanation | 1.3.6.1.4.1.5597.30.1.1.6.38 | DisplayString | read-write | current |
| mbgLtNgCfgSecurity OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.2 | |||
| mbgLtNgCfgLoginAccess OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.2.0 | |||
| mbgLtNgCfgDisableRootLogin OBJECT-TYPE do not allow user 'root' to login | 1.3.6.1.4.1.5597.30.1.2.0.1 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgAllowNetworkDiscovery OBJECT-TYPE allow LANTIME to be discovered via network mdns | 1.3.6.1.4.1.5597.30.1.2.0.2 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgFrontPanel OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.2.1 | |||
| mbgLtNgCfgLockFrontPanel OBJECT-TYPE do not allow usage of the front panel | 1.3.6.1.4.1.5597.30.1.2.1.1 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgDisableUsbPort OBJECT-TYPE do not allow usage of front USB port | 1.3.6.1.4.1.5597.30.1.2.1.2 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgSsh OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.2.2 | |||
| mbgLtNgCfgSshKeyLength OBJECT-TYPE ssh key length in bits | 1.3.6.1.4.1.5597.30.1.2.2.1 | Unsigned32 (768 | 1024 | 2048 | 4096 | 8192 | 16384 | 32768) | read-write | current |
| mbgLtNgCfgSshShellTimeout OBJECT-TYPE ssh shell timeout in seconds | 1.3.6.1.4.1.5597.30.1.2.2.2 | Unsigned32 (0 | 60 | 120 | 300 | 600 | 3600 | 10800 | 18000 | 86400) | read-write | current |
| mbgLtNgCfgNtp OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.3 | |||
| mbgLtNgCfgNtpTable OBJECT-TYPE a table of configured, external NTP servers | 1.3.6.1.4.1.5597.30.1.3.1 | not-accessible | current | |
| mbgLtNgCfgNtpTableEntry OBJECT-TYPE a list of objects pertaining to a configured,external NTP server | 1.3.6.1.4.1.5597.30.1.3.1.1 | not-accessible | current | |
| mbgLtNgCfgNtpIndex OBJECT-TYPE index (and no.) of external NTP server | 1.3.6.1.4.1.5597.30.1.3.1.1.1 | Unsigned32 (1..7) | not-accessible | current |
| mbgLtNgCfgNtpServerIP OBJECT-TYPE ip address for external NTP server | 1.3.6.1.4.1.5597.30.1.3.1.1.2 | DisplayString | read-write | current |
| mbgLtNgCfgNtpServerKey OBJECT-TYPE key for external NTP server | 1.3.6.1.4.1.5597.30.1.3.1.1.3 | Unsigned32 (0..255) | read-write | current |
| mbgLtNgCfgNtpServerAutokey OBJECT-TYPE is autokey enabled for the external NTP server | 1.3.6.1.4.1.5597.30.1.3.1.1.4 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgNtpServerMinpoll OBJECT-TYPE is autokey enabled for the external NTP server | 1.3.6.1.4.1.5597.30.1.3.1.1.5 | Unsigned32 (4..10) | read-write | current |
| mbgLtNgCfgNtpServerMaxpoll OBJECT-TYPE is autokey enabled for the external NTP server | 1.3.6.1.4.1.5597.30.1.3.1.1.6 | Unsigned32 (4..10) | read-write | current |
| mbgLtNgCfgNtpServerIburst OBJECT-TYPE is autokey enabled for the external NTP server | 1.3.6.1.4.1.5597.30.1.3.1.1.7 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgNtpBMTable OBJECT-TYPE a table of configured, external NTP servers | 1.3.6.1.4.1.5597.30.1.3.2 | not-accessible | current | |
| mbgLtNgCfgNtpBMTableEntry OBJECT-TYPE a list of objects pertaining to an interface and concerning broad-, multi- and manycast | 1.3.6.1.4.1.5597.30.1.3.2.1 | not-accessible | current | |
| mbgLtNgCfgNtpBMIndex OBJECT-TYPE index of interface concerning different NTP modes | 1.3.6.1.4.1.5597.30.1.3.2.1.1 | Unsigned32 (0..16) | not-accessible | current |
| mbgLtNgCfgNtpBroadAddr OBJECT-TYPE address for NTP broadcast mode | 1.3.6.1.4.1.5597.30.1.3.2.1.2 | DisplayString | read-only | current |
| mbgLtNgCfgNtpBroadSymKey OBJECT-TYPE symmetric key number for broadcast | 1.3.6.1.4.1.5597.30.1.3.2.1.3 | Unsigned32 (0..10) | read-only | current |
| mbgLtNgCfgNtpBroadInterval OBJECT-TYPE NTP broadcast interval on specific interval | 1.3.6.1.4.1.5597.30.1.3.2.1.4 | Unsigned32 (0..10) | read-only | current |
| mbgLtNgCfgNtpBroadUseAutokey OBJECT-TYPE use autokey for broadcast | 1.3.6.1.4.1.5597.30.1.3.2.1.5 | MeinbergSwitch | read-only | current |
| mbgLtNgCfgNtpEnableMulticast OBJECT-TYPE enable or disable multicast mode | 1.3.6.1.4.1.5597.30.1.3.3 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgNtpMultiAddr OBJECT-TYPE address for NTP multicast mode | 1.3.6.1.4.1.5597.30.1.3.4 | DisplayString | read-write | current |
| mbgLtNgCfgNtpMultiInterval OBJECT-TYPE NTP multicast interval on specific interval | 1.3.6.1.4.1.5597.30.1.3.5 | Unsigned32 | read-write | current |
| mbgLtNgCfgNtpMultiSymKey OBJECT-TYPE symmetric key number for multicast | 1.3.6.1.4.1.5597.30.1.3.6 | Unsigned32 | read-write | current |
| mbgLtNgCfgNtpMultiUseAutokey OBJECT-TYPE use autokey for multicast | 1.3.6.1.4.1.5597.30.1.3.7 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgNtpEnableManycast OBJECT-TYPE enable or disable manycast mode for this interface | 1.3.6.1.4.1.5597.30.1.3.8 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgNtpManyAddr OBJECT-TYPE address for NTP manycast mode | 1.3.6.1.4.1.5597.30.1.3.9 | DisplayString | read-write | current |
| mbgLtNgCfgNtpManySymKey OBJECT-TYPE symmetric key number for manycast | 1.3.6.1.4.1.5597.30.1.3.11 | Unsigned32 | read-write | current |
| mbgLtNgCfgNtpManyUseAutokey OBJECT-TYPE use autokey for manycast | 1.3.6.1.4.1.5597.30.1.3.12 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgNtpLocalClkStratum OBJECT-TYPE stratum of local clock | 1.3.6.1.4.1.5597.30.1.3.13 | Unsigned32 (1..16) | read-write | current |
| mbgLtNgCfgNtpDisableLocalClk OBJECT-TYPE disable local clock | 1.3.6.1.4.1.5597.30.1.3.14 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgNtpSpoofLocalTime OBJECT-TYPE NTP outputs local time instead of UTC; see mbgLtNgCfgNtpTimeScale | 1.3.6.1.4.1.5597.30.1.3.15 | MeinbergSwitch | read-write | obsolete |
| mbgLtNgCfgNtpLocalTrustedKeys OBJECT-TYPE local trusted key | 1.3.6.1.4.1.5597.30.1.3.16 | DisplayString | read-write | current |
| mbgLtNgCfgNtpTrusttime OBJECT-TYPE accept async reference clock for this amount of time in seconds | 1.3.6.1.4.1.5597.30.1.3.17 | Unsigned32 | read-write | current |
| mbgLtNgCfgNtpTimeScale OBJECT-TYPE timescale | 1.3.6.1.4.1.5597.30.1.3.18 | INTEGER {utc(0), local(1)} | read-write | current |
| mbgLtNgCfgNtpEnableClientCounter OBJECT-TYPE enable NTP request client counting | 1.3.6.1.4.1.5597.30.1.3.19 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgNtpEnableClientCounterDuration OBJECT-TYPE NTP client counter duration in seconds; 0 means continuously | 1.3.6.1.4.1.5597.30.1.3.20 | Integer32 (0..2147483647) | read-write | current |
| mbgLtNgCfgPtp OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.4 | |||
| mbgLtNgCfgPtpTable OBJECT-TYPE a table of PTPv2 related configurtion variables | 1.3.6.1.4.1.5597.30.1.4.1 | not-accessible | current | |
| mbgLtNgCfgPtpTableEntry OBJECT-TYPE a list of configuration objects pertaining to a PTPv2 module | 1.3.6.1.4.1.5597.30.1.4.1.1 | not-accessible | current | |
| mbgLtNgCfgPtpIndex OBJECT-TYPE index for PTPv2 module | 1.3.6.1.4.1.5597.30.1.4.1.1.1 | Unsigned32 | not-accessible | current |
| mbgLtNgCfgPtpHostname OBJECT-TYPE network hostname | 1.3.6.1.4.1.5597.30.1.4.1.1.2 | DisplayString | read-write | current |
| mbgLtNgCfgPtpDomainname OBJECT-TYPE network domain | 1.3.6.1.4.1.5597.30.1.4.1.1.3 | DisplayString | read-write | current |
| mbgLtNgCfgPtpNameserver1 OBJECT-TYPE ethernet nameserver for hostname resolving | 1.3.6.1.4.1.5597.30.1.4.1.1.4 | DisplayString | read-write | current |
| mbgLtNgCfgPtpNameserver2 OBJECT-TYPE ethernet nameserver for hostname resolving | 1.3.6.1.4.1.5597.30.1.4.1.1.5 | DisplayString | read-write | current |
| mbgLtNgCfgPtpIpv4 OBJECT-TYPE ip address | 1.3.6.1.4.1.5597.30.1.4.1.1.6 | DisplayString | read-write | current |
| mbgLtNgCfgPtpNetmask OBJECT-TYPE netmask | 1.3.6.1.4.1.5597.30.1.4.1.1.7 | DisplayString | read-write | current |
| mbgLtNgCfgPtpGateway OBJECT-TYPE default gateway | 1.3.6.1.4.1.5597.30.1.4.1.1.8 | DisplayString | read-write | current |
| mbgLtNgCfgPtpEnableVlan OBJECT-TYPE Enable VLAN if it is supported | 1.3.6.1.4.1.5597.30.1.4.1.1.9 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgPtpVlanId OBJECT-TYPE VLAN id ranges from 0-4096 | 1.3.6.1.4.1.5597.30.1.4.1.1.10 | Unsigned32 (0..4094) | read-write | current |
| mbgLtNgCfgPtpVlanPriority OBJECT-TYPE VLAN priority ranges from 0-7 | 1.3.6.1.4.1.5597.30.1.4.1.1.11 | Unsigned32 (0..7) | read-write | current |
| mbgLtNgCfgPtpEnableDhcp OBJECT-TYPE Enable DCHP for PTPv2 module | 1.3.6.1.4.1.5597.30.1.4.1.1.12 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgPtpMode OBJECT-TYPE PTP mode | 1.3.6.1.4.1.5597.30.1.4.1.1.13 | INTEGER {multicastSlave(0), unicastSlave(1), multicastMaster(2), unicastMaster(3), multicastAuto(4), bothMaster(5), ntpServer(6), ntpClient(7)} | read-write | current |
| mbgLtNgCfgPtpDelayMechanism OBJECT-TYPE how to calculate delay mechanism | 1.3.6.1.4.1.5597.30.1.4.1.1.14 | INTEGER {e2e(0), p2p(1)} | read-write | current |
| mbgLtNgCfgPtpNetworkProtocol OBJECT-TYPE how to calculate delay mechanism | 1.3.6.1.4.1.5597.30.1.4.1.1.15 | INTEGER {reserved(0), udpIpv4(1), udpIpv6(2), ieee8023(3)} | read-write | current |
| mbgLtNgCfgPtpDomainNumber OBJECT-TYPE ptp domain membership | 1.3.6.1.4.1.5597.30.1.4.1.1.16 | Unsigned32 (0..255) | read-write | current |
| mbgLtNgCfgPtpPriority1 OBJECT-TYPE ptp user defined major priority | 1.3.6.1.4.1.5597.30.1.4.1.1.17 | Unsigned32 (0..255) | read-write | current |
| mbgLtNgCfgPtpPriority2 OBJECT-TYPE ptp user defined minor priority | 1.3.6.1.4.1.5597.30.1.4.1.1.18 | Unsigned32 (0..255) | read-write | current |
| mbgLtNgCfgPtpSyncInterval OBJECT-TYPE value is defined as power of 2; for example: 2 = one message every 4 seconds, -2 = 4 messages every second | 1.3.6.1.4.1.5597.30.1.4.1.1.19 | Integer32 (-7..7) | read-write | current |
| mbgLtNgCfgPtpAnnounceInterval OBJECT-TYPE see 'mbgLtNgCfPtpSyncInterval' for explanation | 1.3.6.1.4.1.5597.30.1.4.1.1.20 | Integer32 (-7..7) | read-write | current |
| mbgLtNgCfgPtpDelayReqInterval OBJECT-TYPE see 'mbgLtNgCfPtpSyncInterval' for explanation | 1.3.6.1.4.1.5597.30.1.4.1.1.21 | Integer32 (-7..7) | read-write | current |
| mbgLtNgCfgPtpTimescale OBJECT-TYPE see 'mbgLtNgCfPtpSyncInterval' for explanation | 1.3.6.1.4.1.5597.30.1.4.1.1.22 | INTEGER {arbitrary(0), ptp(1)} | read-write | current |
| mbgLtNgCfgPtpIpv6Avail OBJECT-TYPE Is IPv6 supported? | 1.3.6.1.4.1.5597.30.1.4.1.1.23 | INTEGER {no(0), yes(1)} | read-only | current |
| mbgLtNgCfgPtpIpv6Mode OBJECT-TYPE IPv6 addressing mode | 1.3.6.1.4.1.5597.30.1.4.1.1.24 | INTEGER {static(0), ra(1), dhcp(2)} | read-write | current |
| mbgLtNgCfgPtpIpv6Address OBJECT-TYPE IPv6 address if supported, else n/a | 1.3.6.1.4.1.5597.30.1.4.1.1.25 | DisplayString | read-write | current |
| mbgLtNgCfgPtpIpv6McastScope OBJECT-TYPE Multicast scope. See RFC 7346 and RFC 4291 | 1.3.6.1.4.1.5597.30.1.4.1.1.26 | INTEGER {intfLocal(1), linkLocal(2), realmLocal(3), adminLocal(4), siteLocal(5), orgaLocal(8), globalScope(14)} | read-write | current |
| mbgLtNgCfgPtpDisableSsh OBJECT-TYPE Disable SSH for PTP port | 1.3.6.1.4.1.5597.30.1.4.1.1.27 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgPtpDscpClass OBJECT-TYPE DSCP classification value ranges from 0-64 | 1.3.6.1.4.1.5597.30.1.4.1.1.28 | Unsigned32 (0..64) | read-write | current |
| mbgLtNgCfgPtpMcastTtl OBJECT-TYPE Multicast TTL value ranges from 0-255 | 1.3.6.1.4.1.5597.30.1.4.1.1.29 | Unsigned32 (0..255) | read-write | current |
| mbgLtNgCfgPtpOpMode OBJECT-TYPE General PTP operation mode | 1.3.6.1.4.1.5597.30.1.4.1.1.30 | INTEGER {ptp(0), ntp(1)} | read-write | current |
| mbgLtNgCfgPtpProfile OBJECT-TYPE PTP profile | 1.3.6.1.4.1.5597.30.1.4.1.1.31 | INTEGER {custom(0), defE2eIeee15882008(1), defP2pIeee15882008(2), powIeeeC37238(3), telItuTG82651(4), telItuTG82751(5), smpteSt20592(6)} | read-only | current |
| mbgLtNgCfgPtpHybridMode OBJECT-TYPE Run card in hybrid mode | 1.3.6.1.4.1.5597.30.1.4.1.1.32 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgPtpUcastMstAddr OBJECT-TYPE IP address of unicast master when in slave mode. Only 1!!! is shown and can be set. | 1.3.6.1.4.1.5597.30.1.4.1.1.33 | DisplayString | read-write | current |
| mbgLtNgCfgPtpAnnRcptTmout OBJECT-TYPE Timeout for announce messages | 1.3.6.1.4.1.5597.30.1.4.1.1.34 | Unsigned32 (2..255) | read-write | current |
| mbgLtNgCfgPtpMessageDuration OBJECT-TYPE Time period until master stops sending messages [s] | 1.3.6.1.4.1.5597.30.1.4.1.1.35 | Unsigned32 (10..65535) | read-write | current |
| mbgLtNgCfgPtpSyncEAvail OBJECT-TYPE Is SyncE supported? | 1.3.6.1.4.1.5597.30.1.4.1.1.36 | MeinbergSwitch | read-only | current |
| mbgLtNgCfgPtpSyncEEnabled OBJECT-TYPE Is Sync-E enabled if supported? | 1.3.6.1.4.1.5597.30.1.4.1.1.37 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgPtpSyncEQltLvlSelEnable OBJECT-TYPE Enable quality selection? | 1.3.6.1.4.1.5597.30.1.4.1.1.38 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgPtpSyncESdhNwOption OBJECT-TYPE Sdh network option | 1.3.6.1.4.1.5597.30.1.4.1.1.39 | INTEGER {opt1(0), opt2(1)} | read-write | current |
| mbgLtNgCfgPtpSyncEInputSsm OBJECT-TYPE Input SSMs combied for both options. You should be aware of using which code when. | 1.3.6.1.4.1.5597.30.1.4.1.1.40 | INTEGER {stuUkn(0), prs(1), prc(2), inv3(3), ssuATnc(4), inv5(5), inv6(6), st2(7), ssuB(8), inv9(9), eec2St3(10), eec1Sec(11), smc(12), st3e(13), prov(14), dnuDus(15)} | read-write | current |
| mbgLtNgCfgPtpSyncEOutputSsm OBJECT-TYPE Input SSMs combined for both options. You should be aware of using which code when. | 1.3.6.1.4.1.5597.30.1.4.1.1.41 | INTEGER {stuUkn(0), prs(1), prc(2), inv3(3), ssuATnc(4), inv5(5), inv6(6), st2(7), ssuB(8), inv9(9), eec2St3(10), eec1Sec(11), smc(12), st3e(13), prov(14), dnuDus(15)} | read-write | current |
| mbgLtNgCfgPtpSyncEGbitCopperMode OBJECT-TYPE Gigabit copper modes | 1.3.6.1.4.1.5597.30.1.4.1.1.42 | INTEGER {auto(0), forceSyncEAuto(1), forceOrIsMaster(2), forceOrIsSlave(3), preferMaster(4), preferSlave(5)} | read-write | current |
| mbgLtNgCfgPtpMiscEnable1Step OBJECT-TYPE Enable PTP 1 step if supported | 1.3.6.1.4.1.5597.30.1.4.1.1.43 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgPtpDisableMgmtMsgs OBJECT-TYPE Disable management messages if suppported | 1.3.6.1.4.1.5597.30.1.4.1.1.44 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgPtpOutput1 OBJECT-TYPE Additional I/O output if suppported | 1.3.6.1.4.1.5597.30.1.4.1.1.45 | INTEGER {off(0), pps(1), mhz10(2), khzGPS2048(3), mhzGPS10(4), ppsGPS(5)} | read-write | current |
| mbgLtNgCfgPtpOutput2 OBJECT-TYPE Additional I/O output if suppported | 1.3.6.1.4.1.5597.30.1.4.1.1.46 | INTEGER {off(0), pps(1), mhz10(2), khzGPS2048(3), mhzGPS10(4), ppsGPS(5)} | read-write | current |
| mbgLtNgCfgPtpCmd OBJECT-TYPE Configuration commands | 1.3.6.1.4.1.5597.30.1.4.2 | INTEGER {none(0), configure(1), reset(2), apply(3)} | read-write | current |
| mbgLtNgCfgSystem OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.5 | |||
| mbgLtNgCfgGeneral OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.5.0 | |||
| mbgLtNgCfgWebLanguage OBJECT-TYPE set language for web interface | 1.3.6.1.4.1.5597.30.1.5.0.1 | INTEGER {notAvailable(0), englisch(1), german(2)} | read-only | current |
| mbgLtNgCfgActivateChangesAsStartup OBJECT-TYPE activate changes automatically as startup configuration | 1.3.6.1.4.1.5597.30.1.5.0.2 | MeinbergSwitch | read-write | current |
| mbgLtNgCfgDisplay OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.1.5.1 | |||
| mbgLtNgCfgEnableFrontPanelLight OBJECT-TYPE active light at front panel | 1.3.6.1.4.1.5597.30.1.5.1.1 | MeinbergSwitch | read-write | current |
| mbgLtNgCommands OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.2 | |||
| mbgLtNgCmdExecute OBJECT-TYPE Send a command to the timeserver to be executed; Attention: Command should be executed with a timeout of 120 seconds and 0 retries | 1.3.6.1.4.1.5597.30.2.1 | INTEGER {none(0), applyChanges(1), saveChanges(2), saveAndApplyChanges(3), startFirmwareUpdate(4), reboot(5), resendErrorConditions(6), sendTestNotifications(7)} | read-write | current |
| mbgLtNgCmdSetTime OBJECT-TYPE Reference time can be set via a date-time string in format: yyyy-mm-dd hh:mm:ss Time is interpreted as configured via web interface at menu: 'Receiver'->'Time Zone' It is mandatory to unplug the receiver's antenna to make this work. and strongly advised to execute a SNMPSET WITHOUT retries and a timeout value greater than 60 seconds. Otherwise there might come up unforeseen issues. SNMPGET always returns default value. | 1.3.6.1.4.1.5597.30.2.2 | DisplayString | read-write | current |
| mbgLtNgTrapNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.3 | |||
| mbgLtNgTraps OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.3.0 | |||
| mbgLtNgTrapMessage OBJECT-TYPE used as a payload object for all traps, holds a clear text event message | 1.3.6.1.4.1.5597.30.3.0.100 | DisplayString | read-only | current |
| mbgLtNgConformance OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.90 | |||
| mbgLtNgCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.90.1 | |||
| mbgLtNgGroups OBJECT-IDENTITY | 1.3.6.1.4.1.5597.30.90.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| mbgLtNgTrapNTPNotSync NOTIFICATION-TYPE trap to be sent when NTP is not synchronised | 1.3.6.1.4.1.5597.30.3.0.1 | current |
| mbgLtNgTrapNTPStopped NOTIFICATION-TYPE trap to be sent when NTP is stopped | 1.3.6.1.4.1.5597.30.3.0.2 | current |
| mbgLtNgTrapServerBoot NOTIFICATION-TYPE trap to be sent when time server has finished boot sequence | 1.3.6.1.4.1.5597.30.3.0.3 | current |
| mbgLtNgTrapReceiverNotResponding NOTIFICATION-TYPE trap to be sent when receiver is not responding | 1.3.6.1.4.1.5597.30.3.0.4 | current |
| mbgLtNgTrapReceiverNotSync NOTIFICATION-TYPE trap to be sent when receiver is not synchronised | 1.3.6.1.4.1.5597.30.3.0.5 | current |
| mbgLtNgTrapAntennaFaulty NOTIFICATION-TYPE trap to be sent when connection to antenna is broken | 1.3.6.1.4.1.5597.30.3.0.6 | current |
| mbgLtNgTrapAntennaReconnect NOTIFICATION-TYPE trap to be sent when antenna has been reconnected | 1.3.6.1.4.1.5597.30.3.0.7 | current |
| mbgLtNgTrapConfigChanged NOTIFICATION-TYPE trap to be sent when timeserver reloaded its configuration | 1.3.6.1.4.1.5597.30.3.0.8 | current |
| mbgLtNgTrapLeapSecondAnnounced NOTIFICATION-TYPE trap to be sent when a leap second has been announced | 1.3.6.1.4.1.5597.30.3.0.9 | current |
| mbgLtNgTrapSHSTimeLimitError NOTIFICATION-TYPE trap to be sent when SHS timelimit exceeded | 1.3.6.1.4.1.5597.30.3.0.10 | current |
| mbgLtNgTrapSecondaryRecNotSync NOTIFICATION-TYPE trap to be sent when secondary receiver in SHS system is not synchronised | 1.3.6.1.4.1.5597.30.3.0.11 | current |
| mbgLtNgTrapPowerSupplyFailure NOTIFICATION-TYPE trap to be sent when one of the redundant power supplies fails | 1.3.6.1.4.1.5597.30.3.0.12 | current |
| mbgLtNgTrapAntennaShortCircuit NOTIFICATION-TYPE trap to be sent when a connected antenna fails due to a short circuit | 1.3.6.1.4.1.5597.30.3.0.13 | current |
| mbgLtNgTrapReceiverSync NOTIFICATION-TYPE trap to be sent when receiver is synchronised | 1.3.6.1.4.1.5597.30.3.0.14 | current |
| mbgLtNgTrapNTPClientAlarm NOTIFICATION-TYPE trap to be sent when an NTP Client Monitoring alarm occurs, e.g. when a monitored client is not reachable. | 1.3.6.1.4.1.5597.30.3.0.15 | current |
| mbgLtNgTrapPowerSupplyUp NOTIFICATION-TYPE trap to be sent when a power supply returned to a healthy state. | 1.3.6.1.4.1.5597.30.3.0.16 | current |
| mbgLtNgTrapNetworkDown NOTIFICATION-TYPE trap to be sent when a monitored network port is down. | 1.3.6.1.4.1.5597.30.3.0.17 | current |
| mbgLtNgTrapNetworkUp NOTIFICATION-TYPE trap to be sent when a monitored network port is up. | 1.3.6.1.4.1.5597.30.3.0.18 | current |
| mbgLtNgTrapSecondaryRecNotResp NOTIFICATION-TYPE trap to be sent when secondary receiver is not responding | 1.3.6.1.4.1.5597.30.3.0.19 | current |
| mbgLtNgTrapXmrLimitExceeded NOTIFICATION-TYPE trap to be sent when a reference offset exceeds the configured limit | 1.3.6.1.4.1.5597.30.3.0.30 | current |
| mbgLtNgTrapXmrRefDisconnect NOTIFICATION-TYPE trap to be sent when a reference signal has been lost | 1.3.6.1.4.1.5597.30.3.0.31 | current |
| mbgLtNgTrapXmrRefReconnect NOTIFICATION-TYPE trap to be sent when a reference signal recovered | 1.3.6.1.4.1.5597.30.3.0.32 | current |
| mbgLtNgTrapFdmError NOTIFICATION-TYPE trap to be sent when the Fdm module generates an alarm | 1.3.6.1.4.1.5597.30.3.0.33 | current |
| mbgLtNgTrapSHSTimeLimitWarning NOTIFICATION-TYPE trap to be sent when SHS warning limit exceeded | 1.3.6.1.4.1.5597.30.3.0.34 | current |
| mbgLtNgTrapSecondaryRecSync NOTIFICATION-TYPE trap to be sent when secondary receiver is synchronised | 1.3.6.1.4.1.5597.30.3.0.35 | current |
| mbgLtNgTrapNTPSync NOTIFICATION-TYPE trap to be sent when NTP is synchronised | 1.3.6.1.4.1.5597.30.3.0.36 | current |
| mbgLtNgTrapPtpPortDisconnected NOTIFICATION-TYPE trap to be sent when PTP network port got disconnected | 1.3.6.1.4.1.5597.30.3.0.37 | current |
| mbgLtNgTrapPtpPortConnected NOTIFICATION-TYPE trap to be sent when PTP network port got connected | 1.3.6.1.4.1.5597.30.3.0.38 | current |
| mbgLtNgTrapPtpStateChanged NOTIFICATION-TYPE trap to be sent when PTP state changed (e.g. from 'passive' to 'master') | 1.3.6.1.4.1.5597.30.3.0.39 | current |
| mbgLtNgTrapPtpError NOTIFICATION-TYPE trap to be sent when PTP raised an error | 1.3.6.1.4.1.5597.30.3.0.40 | current |
| mbgLtNgTrapLowSystemResources NOTIFICATION-TYPE trap to be sent when system is running on low resources | 1.3.6.1.4.1.5597.30.3.0.41 | current |
| mbgLtNgTrapFanDown NOTIFICATION-TYPE trap to be sent when fan goes down | 1.3.6.1.4.1.5597.30.3.0.45 | current |
| mbgLtNgTrapFanUp NOTIFICATION-TYPE trap to be sent when fan comes up | 1.3.6.1.4.1.5597.30.3.0.46 | current |
| mbgLtNgTrapCertificateExpired NOTIFICATION-TYPE trap to be sent when certificate expired or will expire | 1.3.6.1.4.1.5597.30.3.0.47 | current |
| mbgLtNgTrapSufficientSystemResources NOTIFICATION-TYPE trap to be sent when system has regained sufficient resources | 1.3.6.1.4.1.5597.30.3.0.48 | current |
| mbgLtNgTrapOscillatorWarmedUp NOTIFICATION-TYPE trap to be sent when oscillator is not warmed up | 1.3.6.1.4.1.5597.30.3.0.49 | current |
| mbgLtNgTrapOscillatorNotWarmedUp NOTIFICATION-TYPE trap to be sent when oscillator is warmed up | 1.3.6.1.4.1.5597.30.3.0.50 | current |
| mbgLtNgTrapXmrRefChanged NOTIFICATION-TYPE trap to be sent when XMR reference source changed | 1.3.6.1.4.1.5597.30.3.0.51 | current |
| mbgLtNgTrapClusterMasterChanged NOTIFICATION-TYPE trap to be sent when cluster mode is active and cluster changed | 1.3.6.1.4.1.5597.30.3.0.52 | current |
| mbgLtNgTrapClusterFalsetickerDetected NOTIFICATION-TYPE trap to be sent when cluster mode is active and a cluster member is dectected as falseticker | 1.3.6.1.4.1.5597.30.3.0.53 | current |
| mbgLtNgTrapClusterFalsetickerCleared NOTIFICATION-TYPE trap to be sent when cluster mode is active and a cluster member is no longer a falseticker | 1.3.6.1.4.1.5597.30.3.0.54 | current |
| mbgLtNgTrapSHSTimeLimitOk NOTIFICATION-TYPE trap to be sent when SHS timelimit error has been acknowledged or time difference drops below warning limit. | 1.3.6.1.4.1.5597.30.3.0.55 | current |
| mbgLtNgTrapIMSError NOTIFICATION-TYPE trap to be sent when an IMS module is not responsive anymore, has got temperature issues, etc. ... | 1.3.6.1.4.1.5597.30.3.0.56 | current |
| mbgLtNgTrapIMSOk NOTIFICATION-TYPE trap to be sent when an IMS module returns to healthy state. | 1.3.6.1.4.1.5597.30.3.0.57 | current |
| mbgLtNgTrapFDMOk NOTIFICATION-TYPE trap to be sent when an FDM module returns to healthy state. | 1.3.6.1.4.1.5597.30.3.0.58 | current |
| mbgLtNgTrapNTPOffsetLimitExceeded NOTIFICATION-TYPE trap to be sent when monitoring an NTP client and its offset limit is exceeded | 1.3.6.1.4.1.5597.30.3.0.59 | current |
| mbgLtNgTrapNTPOffsetLimitOk NOTIFICATION-TYPE trap to be sent when monitoring an NTP client and its offset limit is back again in a valid range | 1.3.6.1.4.1.5597.30.3.0.60 | current |
| mbgLtNgTrapNormalOperation NOTIFICATION-TYPE trap to be sent when the system returned to a healthy state | 1.3.6.1.4.1.5597.30.3.0.77 | current |
| mbgLtNgTrapHeartbeat NOTIFICATION-TYPE trap to be sent periodically to indicate that time server is still alive | 1.3.6.1.4.1.5597.30.3.0.88 | current |
| mbgLtNgTrapTestNotification NOTIFICATION-TYPE trap to be sent when a test notification has been requested | 1.3.6.1.4.1.5597.30.3.0.99 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| mbgLtNgCompliance MODULE-COMPLIANCE The compliance statement for SNMP entities which implement version 2 of the LANTIME MIB | 1.3.6.1.4.1.5597.30.90.1.1 | current |
| mbgLtNgObjectsGroup OBJECT-GROUP The collection of objects for the LANTIME MIB | 1.3.6.1.4.1.5597.30.90.2.1 | current |
| mbgLtNgTrapsGroup NOTIFICATION-GROUP The collection of traps for the LANTIME MIB | 1.3.6.1.4.1.5597.30.90.2.2 | current |