LUXN-MIB
- Registered at
- 1.3.6.1.4.1.4253
- Namespace
- zhone
- Source file
LUXN-MIB- Digest
sha256:4fbc49f40a2be41bb29e061caabc3d67ffb0f8b66d907cb22a4d0850f9690678
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, Gauge32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
LUXN-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| AlarmType type | ||||
| Boolean type | ||||
| CardCycleMode type | ||||
| CardLocation type | ||||
| CardName type | ||||
| CardShelf type | ||||
| CardSlot type | ||||
| CardState type | ||||
| CardStatus type | ||||
| CardType type | ||||
| ChassisType type | ||||
| DateAndTime type | ||||
| DownloadLocation type | ||||
| DownloadShelf type | ||||
| DownloadSlot type | ||||
| DownloadStatus type | ||||
| DownloadType type | ||||
| EncryptedCommunity type | ||||
| EntityName type | ||||
| EventBuffer type | ||||
| FileName type | ||||
| FlagType type | ||||
| FtpMode type | ||||
| HashedPasswd type | ||||
| HistoryMode type | ||||
| LinkName type | ||||
| LogonID type | ||||
| ModelNum type | ||||
| ModelString type | ||||
| NodeName type | ||||
| OSMode type | ||||
| OSState type | ||||
| PathIdName type | ||||
| PortIndex type | ||||
| RebootType type | ||||
| RedundancyMode type | ||||
| ReleaseDate type | ||||
| ResetType type | ||||
| RingIdName type | ||||
| SerialString type | ||||
| SfpSerialString type | ||||
| ShelfInput type | ||||
| SlotInput type | ||||
| Timezone type | ||||
| TrapStatus type | ||||
| UpdateOSMode type | ||||
| UserBuffer type | ||||
| VersionString type | ||||
| ZmsAdminString type | ||||
| ZmsFileName type |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| luxN OBJECT-IDENTITY | 1.3.6.1.4.1.4253 | |||
| configuration OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1 | |||
| manufacturing OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.1 | |||
| mfgName OBJECT-TYPE Manufacturing name of the device. Up to 30 characters | 1.3.6.1.4.1.4253.1.1.1 | DisplayString (SIZE(0..30)) | read-only | mandatory |
| mfgDate OBJECT-TYPE Date and Time of manufacturing of the chassis | 1.3.6.1.4.1.4253.1.1.2 | DateAndTime | read-only | mandatory |
| mfgSerialNum OBJECT-TYPE Serial # of the Chassis. | 1.3.6.1.4.1.4253.1.1.3 | SerialString | read-only | mandatory |
| mfgModelType OBJECT-TYPE Model type of the chassis. Up to 10 characters | 1.3.6.1.4.1.4253.1.1.4 | ModelString | not-accessible | mandatory |
| mfgDefaultID OBJECT-TYPE Default one-time user ID. This ID should be used for the first time access to the system. This ID will not be accepted once a real user ID is added. | 1.3.6.1.4.1.4253.1.1.5 | LogonID | read-only | mandatory |
| mfgDfltPasswd OBJECT-TYPE Default one-time password to go with the default user ID. The password may contain non-printable characters up to 10 ASCII characters. Passwords are hashed and are for comparison only | 1.3.6.1.4.1.4253.1.1.6 | HashedPasswd | read-only | mandatory |
| mfgNumShelves OBJECT-TYPE Number of shelves in the chassis. This number reflects the number of rows of the table below. This number is automatically adjusted everytime a row is added to the table below. | 1.3.6.1.4.1.4253.1.1.9 | CardShelf | read-only | mandatory |
| mfgShelfTable OBJECT-TYPE This table represents the number of shelves and the number of slots per shelf in the chassis. | 1.3.6.1.4.1.4253.1.1.10 | not-accessible | mandatory | |
| mfgShelfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.1.10.1 | not-accessible | mandatory | |
| mfgShelfID OBJECT-TYPE Integer ID of each shelf in the chassis. The shelf number is always one for both GM1608 and GM3217. In the case of of GM3234, the bottom shelf is 1 while the top shelf is 2. As for GMX128, the order of numbering is from the top shelf to the bottom shelf. In other words, the top shelf is assigned 1. | 1.3.6.1.4.1.4253.1.1.10.1.1 | CardShelf | read-only | mandatory |
| mfgNumSlots OBJECT-TYPE total number of slots in a given shelf. | 1.3.6.1.4.1.4253.1.1.10.1.2 | CardSlot | read-only | mandatory |
| mfgCRCChecksum OBJECT-TYPE 32 bit CRC of the manufacturing section. This CRC is automatically calculated everytime information is updated from the manufacturing section. The manufacturing section is static once the chassis leaves the LuxN manufacturing premise. | 1.3.6.1.4.1.4253.1.1.11 | DisplayString (SIZE(0..8)) | read-only | mandatory |
| mfgChassisType OBJECT-TYPE Type of chassis. | 1.3.6.1.4.1.4253.1.1.12 | ChassisType | read-only | mandatory |
| mfgPsType OBJECT-TYPE Type of power supplies. | 1.3.6.1.4.1.4253.1.1.13 | INTEGER {dcOny(1), acOnly(2), mixedDcAc(3), unknown(4)} | read-only | mandatory |
| mfgCleiNum OBJECT-TYPE CLEI number for the chassis. | 1.3.6.1.4.1.4253.1.1.14 | DisplayString | read-only | mandatory |
| cp OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.2 | |||
| cpIpAddress OBJECT-TYPE IP Address of the Active Communication Processor | 1.3.6.1.4.1.4253.1.2.1 | IpAddress | read-write | mandatory |
| cpNetMask OBJECT-TYPE Net mask for the Active Communication Processor | 1.3.6.1.4.1.4253.1.2.2 | IpAddress | read-write | mandatory |
| cpMIBVersion OBJECT-TYPE Version of the LuxN MIB implemented by this device. This value may be reset everytime a new CP code is downloaded. | 1.3.6.1.4.1.4253.1.2.3 | VersionString | read-only | mandatory |
| cpBootPromVer OBJECT-TYPE The current version string of the Boot PROM code | 1.3.6.1.4.1.4253.1.2.4 | VersionString | read-only | mandatory |
| cpROMSize OBJECT-TYPE Total Size of the ROM in Kilobyes | 1.3.6.1.4.1.4253.1.2.5 | INTEGER (1..16384) | not-accessible | mandatory |
| cpNumSubDiv OBJECT-TYPE Number of the subdivisions of the ROM. | 1.3.6.1.4.1.4253.1.2.6 | INTEGER (1..20) | read-only | mandatory |
| cpSubDivTable OBJECT-TYPE This table represents the number of sub divisions and the size of each subdivision in ROM memory | 1.3.6.1.4.1.4253.1.2.7 | not-accessible | mandatory | |
| cpSubDivEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.2.7.1 | not-accessible | mandatory | |
| cpSubDivIndex OBJECT-TYPE Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM. | 1.3.6.1.4.1.4253.1.2.7.1.1 | INTEGER (1..20) | read-only | mandatory |
| cpSubDivDescr OBJECT-TYPE Display Name of each Sub Division in ROM | 1.3.6.1.4.1.4253.1.2.7.1.2 | DisplayString (SIZE(0..20)) | read-only | mandatory |
| cpSubDivSize OBJECT-TYPE Size of each sub division in ROM in bytes | 1.3.6.1.4.1.4253.1.2.7.1.3 | INTEGER (1..3145728) | read-only | mandatory |
| cpSubDivOffset OBJECT-TYPE Starting address of each sub division in the ROM in HEX notation. | 1.3.6.1.4.1.4253.1.2.7.1.4 | OCTET STRING (SIZE(0..8)) | not-accessible | mandatory |
| cpSubDivImgVersion OBJECT-TYPE Display Version of each Images in ROM. | 1.3.6.1.4.1.4253.1.2.7.1.5 | DisplayString | read-only | mandatory |
| cpSubDivImgDBVersion OBJECT-TYPE Display Database Version of each Images in ROM. | 1.3.6.1.4.1.4253.1.2.7.1.6 | DisplayString | read-only | mandatory |
| cpTable OBJECT-TYPE This table represents the information for each active or standby communication processor | 1.3.6.1.4.1.4253.1.2.8 | not-accessible | mandatory | |
| cpEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.2.8.1 | not-accessible | mandatory | |
| cpCardShelf OBJECT-TYPE The shelf the card is in. | 1.3.6.1.4.1.4253.1.2.8.1.1 | CardShelf | read-only | mandatory |
| cpCardSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.1.2.8.1.2 | CardSlot | read-only | mandatory |
| cpMode OBJECT-TYPE Type of the communication processor. The valid types are Active or Standby. | 1.3.6.1.4.1.4253.1.2.8.1.3 | RedundancyMode | read-only | mandatory |
| cpDsgntdMode OBJECT-TYPE Designation Type of the communication processor. The valid types are Active or Standby. | 1.3.6.1.4.1.4253.1.2.8.1.4 | RedundancyMode | read-only | mandatory |
| cpState OBJECT-TYPE The state of the CP card. | 1.3.6.1.4.1.4253.1.2.8.1.5 | CardState | read-only | mandatory |
| cpMacAddr OBJECT-TYPE MAC address of the Communication processor in HEX | 1.3.6.1.4.1.4253.1.2.8.1.6 | OCTET STRING (SIZE(0..6)) | read-only | mandatory |
| cpName OBJECT-TYPE Display (Network) name of the Communication processor | 1.3.6.1.4.1.4253.1.2.8.1.7 | DisplayString (SIZE(0..32)) | read-write | mandatory |
| cpMfgDate OBJECT-TYPE Date and Time of manufacturing of the CP card | 1.3.6.1.4.1.4253.1.2.8.1.8 | DateAndTime | not-accessible | mandatory |
| cpSerialNum OBJECT-TYPE Serial # of the CP card. | 1.3.6.1.4.1.4253.1.2.8.1.9 | SerialString | read-only | mandatory |
| cpModelType OBJECT-TYPE Model type of the CP. | 1.3.6.1.4.1.4253.1.2.8.1.10 | CardType | read-only | mandatory |
| cpFWVersionID OBJECT-TYPE The current version string of the CP FW code | 1.3.6.1.4.1.4253.1.2.8.1.11 | VersionString | read-only | mandatory |
| cpSetState OBJECT-TYPE Instruct the CP to do a warmboot. A get on this will always return an other. | 1.3.6.1.4.1.4253.1.2.8.1.12 | RebootType | read-write | mandatory |
| cpHWName OBJECT-TYPE Display Hardware name of the CP Card. | 1.3.6.1.4.1.4253.1.2.8.1.13 | DisplayString (SIZE(0..32)) | read-only | mandatory |
| cpCleiNum OBJECT-TYPE CLEI number of the mux/dmux Card. | 1.3.6.1.4.1.4253.1.2.8.1.14 | DisplayString | read-only | mandatory |
| cpModelNum OBJECT-TYPE Model number of the CP card. Up to 15 characters | 1.3.6.1.4.1.4253.1.2.8.1.15 | DisplayString | read-only | mandatory |
| cpSetMode OBJECT-TYPE Toggle the Active/Standby mode of the active CP. | 1.3.6.1.4.1.4253.1.2.9 | RedundancyMode | read-write | mandatory |
| cpSNMPTrapHost1 OBJECT-TYPE IP Address of the first SNMP Trap host. A NULL IP address means no TRAP should be sent to this address. Duplicate IP addresses will be rejected. | 1.3.6.1.4.1.4253.1.2.10 | IpAddress | read-write | mandatory |
| cpSNMPTrapHost2 OBJECT-TYPE IP Address of the second SNMP Trap host. A NULL IP address means no TRAP should be sent to this address. Duplicate IP addresses will be rejected. | 1.3.6.1.4.1.4253.1.2.11 | IpAddress | read-write | mandatory |
| cpSNMPTrapHost3 OBJECT-TYPE IP Address of the third SNMP Trap host. A NULL IP address means no TRAP should be sent to this address. Duplicate IP addresses will be rejected. | 1.3.6.1.4.1.4253.1.2.12 | IpAddress | read-write | mandatory |
| cpSNMPSendTrap OBJECT-TYPE If set to true, traps will be sent out. If set to false, traps will not be sent out. This variable is reset to true (enable) on each boot cycle. | 1.3.6.1.4.1.4253.1.2.13 | Boolean | read-write | mandatory |
| cpGateway OBJECT-TYPE Gateway IP Address of the Active Communication Processor. A NULL IP address means Gateway hasn't been configured. | 1.3.6.1.4.1.4253.1.2.14 | IpAddress | read-write | mandatory |
| cpMaxSessions OBJECT-TYPE Maximum allowed Telnet Sessions on the Active Communication Processor. Valid values are 1 to 6. | 1.3.6.1.4.1.4253.1.2.15 | INTEGER (1..6) | read-write | mandatory |
| cpSessionTimeout OBJECT-TYPE Maximum timeout (in seconds) that can be set for a Telnet session on the Active Communication Processor. Valid values are greater than 30 secs. | 1.3.6.1.4.1.4253.1.2.16 | INTEGER | read-write | mandatory |
| cpDate OBJECT-TYPE Current Date on the Active Communication Processor. The format is in the form of mm-dd-yy in which mm is the two digit month, dd is the two digit day of the month, and yy is the two digit year. | 1.3.6.1.4.1.4253.1.2.17 | DateAndTime | read-write | mandatory |
| cpTime OBJECT-TYPE Current Time on the Active Communication Processor. The format is in the form of hh:mm:ss in which hh is the hour, mm is the minute and ss is the second. The valid values for hour goes from 0 to 23. In order to work with LuxN NMS, it needs to be set to GMT time | 1.3.6.1.4.1.4253.1.2.18 | DateAndTime | read-write | mandatory |
| cpGetCommunity OBJECT-TYPE User configurable SNMP Get Community String. | 1.3.6.1.4.1.4253.1.2.19 | EncryptedCommunity | read-write | mandatory |
| cpSetCommunity OBJECT-TYPE User Configurable SNMP Set Community String. | 1.3.6.1.4.1.4253.1.2.20 | EncryptedCommunity | read-write | mandatory |
| cpSystemName OBJECT-TYPE User Configurable System Name. | 1.3.6.1.4.1.4253.1.2.21 | DisplayString (SIZE(0..59)) | read-write | mandatory |
| cpSNMPTrapCommunity1 OBJECT-TYPE User configurable trap community string for first trap host. Will return an error if the corresponding trap host is invalid or not set. | 1.3.6.1.4.1.4253.1.2.22 | EncryptedCommunity | read-write | mandatory |
| cpSNMPTrapCommunity2 OBJECT-TYPE User configurable trap community string for second trap host. Will return an error if the corresponding trap host is invalid or not set. | 1.3.6.1.4.1.4253.1.2.23 | EncryptedCommunity | read-write | mandatory |
| cpSNMPTrapCommunity3 OBJECT-TYPE User configurable trap community string for third trap host. Will return an error if the corresponding trap host is invalid or not set. | 1.3.6.1.4.1.4253.1.2.24 | EncryptedCommunity | read-write | mandatory |
| cpHttp OBJECT-TYPE HTTP server enabled or not. | 1.3.6.1.4.1.4253.1.2.25 | INTEGER {enabled(1), disabled(2)} | not-accessible | mandatory |
| cpIMNIpAddress OBJECT-TYPE IMN Ip address. Use for IP/IWM | 1.3.6.1.4.1.4253.1.2.26 | IpAddress | read-write | mandatory |
| cpUpsrMode OBJECT-TYPE UPSR mode: enable and disable. | 1.3.6.1.4.1.4253.1.2.27 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| cpAutoModuleUpdate OBJECT-TYPE Flag to automatically enable/disable module update. | 1.3.6.1.4.1.4253.1.2.28 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| cpSNMPTrapHost4 OBJECT-TYPE IP Address of the fourth SNMP Trap host. A NULL IP address means no TRAP should be sent to this address. Duplicate IP addresses will be rejected. | 1.3.6.1.4.1.4253.1.2.29 | IpAddress | read-write | mandatory |
| cpSNMPTrapHost5 OBJECT-TYPE IP Address of the fifth SNMP Trap host. A NULL IP address means no TRAP should be sent to this address. Duplicate IP addresses will be rejected. | 1.3.6.1.4.1.4253.1.2.30 | IpAddress | read-write | mandatory |
| cpSNMPTrapCommunity4 OBJECT-TYPE User configurable trap community string for fourth trap host. Will return an error if the corresponding trap host is invalid or not set. | 1.3.6.1.4.1.4253.1.2.31 | EncryptedCommunity | read-write | mandatory |
| cpSNMPTrapCommunity5 OBJECT-TYPE User configurable trap community string for fifth trap host. Will return an error if the corresponding trap host is invalid or not set. | 1.3.6.1.4.1.4253.1.2.32 | EncryptedCommunity | read-write | mandatory |
| cpSNMPTrapHostPort1 OBJECT-TYPE User configurable trap port for the first trap host. Default value is 162 | 1.3.6.1.4.1.4253.1.2.33 | INTEGER (0..65534) | read-write | mandatory |
| cpSNMPTrapHostPort2 OBJECT-TYPE User configurable trap port for the second trap host. Default value is 162 | 1.3.6.1.4.1.4253.1.2.34 | INTEGER (0..65534) | read-write | mandatory |
| cpSNMPTrapHostPort3 OBJECT-TYPE User configurable trap port for the third trap host. Default value is 162 | 1.3.6.1.4.1.4253.1.2.35 | INTEGER (0..65534) | read-write | mandatory |
| cpSNMPTrapHostPort4 OBJECT-TYPE User configurable trap port for the fourth trap host. Default value is 162 | 1.3.6.1.4.1.4253.1.2.36 | INTEGER (0..65534) | read-write | mandatory |
| cpSNMPTrapHostPort5 OBJECT-TYPE User configurable trap port for the fifth trap host. Default value is 162 | 1.3.6.1.4.1.4253.1.2.37 | INTEGER (0..65534) | read-write | mandatory |
| cpRedunSubDivTable OBJECT-TYPE This table represents the number of sub divisions and the size of each subdivision in ROM memory of redundant (standby) MPM | 1.3.6.1.4.1.4253.1.2.38 | not-accessible | mandatory | |
| cpRedunSubDivEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.2.38.1 | not-accessible | mandatory | |
| cpRedunSubDivIndex OBJECT-TYPE Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM. | 1.3.6.1.4.1.4253.1.2.38.1.1 | INTEGER (1..20) | read-only | mandatory |
| cpRedunSubDivDescr OBJECT-TYPE Display Name of each Sub Division in ROM | 1.3.6.1.4.1.4253.1.2.38.1.2 | DisplayString (SIZE(0..20)) | read-only | mandatory |
| cpRedunSubDivImgVersion OBJECT-TYPE Display Version of each Images in ROM. | 1.3.6.1.4.1.4253.1.2.38.1.3 | DisplayString | read-only | mandatory |
| cpRedunSubDivImgDBVersion OBJECT-TYPE Display Database Version of each Images in ROM. | 1.3.6.1.4.1.4253.1.2.38.1.4 | DisplayString | read-only | mandatory |
| cpTimezone OBJECT-TYPE Specifies the internation time zone used by the MPM to determine system time. The time zone is only used to system time calculations when NTP is enabled | 1.3.6.1.4.1.4253.1.2.39 | Timezone | read-write | mandatory |
| cpNtpState OBJECT-TYPE Specifies whether NTP support is enabled or disabled. | 1.3.6.1.4.1.4253.1.2.40 | INTEGER {enabled(1), disabled(2)} | read-write | mandatory |
| cpNtpTimeserver OBJECT-TYPE Specifies the NTP time server queries for updates. | 1.3.6.1.4.1.4253.1.2.41 | IpAddress | read-write | mandatory |
| cpNtpUpdateInterval OBJECT-TYPE Specifies the NTP time update interval in minutes. | 1.3.6.1.4.1.4253.1.2.42 | INTEGER (5..1440) | read-write | mandatory |
| cpTelnetClient OBJECT-TYPE Enable/disable telnet client for active telnet sessions. | 1.3.6.1.4.1.4253.1.2.43 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| cpLogMask OBJECT-TYPE Set the log mask. The masks are equivalent to syslog priorities. | 1.3.6.1.4.1.4253.1.2.44 | INTEGER {disabled(1), emerg(2), alert(3), crit(4), err(5), warn(6), notice(7), info(8), debug(9)} | read-write | mandatory |
| cpLogServer1 OBJECT-TYPE IP Address of the first log server. A NULL IP address will remove this entry. Duplicate IP addresses will be rejected. | 1.3.6.1.4.1.4253.1.2.45 | IpAddress | read-write | mandatory |
| cpLogServer2 OBJECT-TYPE IP Address of the first log server. A NULL IP address will remove this entry. Duplicate IP addresses will be rejected. | 1.3.6.1.4.1.4253.1.2.46 | IpAddress | read-write | mandatory |
| cpLogServer3 OBJECT-TYPE IP Address of the first log server. A NULL IP address will remove this entry. Duplicate IP addresses will be rejected. | 1.3.6.1.4.1.4253.1.2.47 | IpAddress | read-write | mandatory |
| cpLogServer4 OBJECT-TYPE IP Address of the first log server. A NULL IP address will remove this entry. Duplicate IP addresses will be rejected. | 1.3.6.1.4.1.4253.1.2.48 | IpAddress | read-write | mandatory |
| cpLogServer5 OBJECT-TYPE IP Address of the first log server. A NULL IP address will remove this entry. Duplicate IP addresses will be rejected. | 1.3.6.1.4.1.4253.1.2.49 | IpAddress | read-write | mandatory |
| cc OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.3 | |||
| ccBootPromVer OBJECT-TYPE The current version string of the CC Boot PROM code | 1.3.6.1.4.1.4253.1.3.1 | VersionString | not-accessible | mandatory |
| ccROMSize OBJECT-TYPE Total Size of the CC ROM in Kilobyes | 1.3.6.1.4.1.4253.1.3.2 | INTEGER (0..1024) | not-accessible | mandatory |
| ccNumSubDiv OBJECT-TYPE Number of the subdivisions of the ROM. | 1.3.6.1.4.1.4253.1.3.3 | INTEGER (0..20) | not-accessible | mandatory |
| ccSubDivTable OBJECT-TYPE This table represents the number of sub divisions and the size of each subdivision in ROM memory | 1.3.6.1.4.1.4253.1.3.4 | not-accessible | mandatory | |
| ccSubDivEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.3.4.1 | not-accessible | mandatory | |
| ccSubDivIndex OBJECT-TYPE Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM. | 1.3.6.1.4.1.4253.1.3.4.1.1 | INTEGER (1..20) | not-accessible | mandatory |
| ccSubDivDescr OBJECT-TYPE Display Name of each Sub Division in ROM | 1.3.6.1.4.1.4253.1.3.4.1.2 | DisplayString (SIZE(0..20)) | not-accessible | mandatory |
| ccSubDivSize OBJECT-TYPE Size of each sub division in ROM in kilobytes | 1.3.6.1.4.1.4253.1.3.4.1.3 | INTEGER (1..1024) | not-accessible | mandatory |
| ccSubDivOffset OBJECT-TYPE Starting address of each sub division in the ROM in HEX notation. | 1.3.6.1.4.1.4253.1.3.4.1.4 | OCTET STRING (SIZE(0..8)) | not-accessible | mandatory |
| ccNumber OBJECT-TYPE Number of CC rows in the following table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.3.5 | INTEGER | read-only | mandatory |
| ccTable OBJECT-TYPE This table represents the information for each channel card | 1.3.6.1.4.1.4253.1.3.6 | not-accessible | mandatory | |
| ccEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.3.6.1 | not-accessible | mandatory | |
| ccCardLocation OBJECT-TYPE Location of the card. Valid values are: Local in the same chassis, or remote to this chassis | 1.3.6.1.4.1.4253.1.3.6.1.1 | CardLocation | read-only | mandatory |
| ccCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2 | 1.3.6.1.4.1.4253.1.3.6.1.2 | CardShelf | read-only | mandatory |
| ccCardSlot OBJECT-TYPE The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.3.6.1.3 | SlotInput | read-write | mandatory |
| ccMfgDate OBJECT-TYPE Date and Time of calibration of the CC card | 1.3.6.1.4.1.4253.1.3.6.1.4 | DateAndTime | read-only | mandatory |
| ccSerialNum OBJECT-TYPE Serial # of the CC card. | 1.3.6.1.4.1.4253.1.3.6.1.5 | SerialString | read-only | mandatory |
| ccModelType OBJECT-TYPE Model type of the channel card. | 1.3.6.1.4.1.4253.1.3.6.1.6 | CardType | read-only | mandatory |
| ccName OBJECT-TYPE User configurable name of the channel card | 1.3.6.1.4.1.4253.1.3.6.1.7 | CardName | read-write | mandatory |
| ccFWVersionID OBJECT-TYPE The current version string of the CC FW code | 1.3.6.1.4.1.4253.1.3.6.1.8 | VersionString | read-only | mandatory |
| ccMfgBiasCurrent OBJECT-TYPE Bias current for the optical laser. This is the preset manufacturing value | 1.3.6.1.4.1.4253.1.3.6.1.9 | INTEGER | read-only | mandatory |
| ccMfgModulation OBJECT-TYPE The frequency modulation for the optical laser. This value is the preset manufacturing value. | 1.3.6.1.4.1.4253.1.3.6.1.10 | INTEGER | read-only | mandatory |
| ccMfgApc OBJECT-TYPE The APC value. This value is the preset manufacturing value | 1.3.6.1.4.1.4253.1.3.6.1.11 | INTEGER | read-only | mandatory |
| ccMfgIwmModulation OBJECT-TYPE The frequency modulation for the IWM channel. This value is the preset manufacturing value | 1.3.6.1.4.1.4253.1.3.6.1.12 | INTEGER | read-only | mandatory |
| ccMfgRefClock OBJECT-TYPE The value of the reference clock in decimal notation. For a given value, like 1660-EN, the actual value is 16.60-EN. In otherwords, assume a two digit decimal point, plus any appropriate scaling factor. This value is the preset manufacturing value. | 1.3.6.1.4.1.4253.1.3.6.1.13 | INTEGER {en1660(1), en1944(2), en1953(3)} | not-accessible | mandatory |
| ccMfgClockDiv OBJECT-TYPE The clock divisor. Values are 1250, 622 or 155 in the appropriate clock frequency scale. | 1.3.6.1.4.1.4253.1.3.6.1.14 | INTEGER {dout-1250(1), dout-622(2), dout-155(3)} | not-accessible | mandatory |
| ccBandwidth OBJECT-TYPE The bandwidth of the channel card. | 1.3.6.1.4.1.4253.1.3.6.1.15 | INTEGER {oc3(1), oc12(2), oc48(3), gbEthernet(4), fibreChannel(5), oc192(6), gbE10(9), fibreChannelX2(10)} | read-write | mandatory |
| ccSetState OBJECT-TYPE Instruct the CC to do a warmboot or loopback. A get on this will always return an other. | 1.3.6.1.4.1.4253.1.3.6.1.16 | INTEGER {other(1), warmboot(2), enableLoopback(3), disableLoopback(4)} | read-write | mandatory |
| connMuxChassis OBJECT-TYPE The connected mux chassis. | 1.3.6.1.4.1.4253.1.3.6.1.17 | INTEGER | not-accessible | mandatory |
| connMuxShelf OBJECT-TYPE The connected mux shelf. | 1.3.6.1.4.1.4253.1.3.6.1.18 | ShelfInput | read-only | mandatory |
| connMuxSlot OBJECT-TYPE The connected mux slot. | 1.3.6.1.4.1.4253.1.3.6.1.19 | SlotInput | read-only | mandatory |
| connMuxPort OBJECT-TYPE The connected mux port. | 1.3.6.1.4.1.4253.1.3.6.1.20 | INTEGER | read-only | mandatory |
| connDemuxChassis OBJECT-TYPE The connected demux chassis. | 1.3.6.1.4.1.4253.1.3.6.1.21 | INTEGER | not-accessible | mandatory |
| connDemuxShelf OBJECT-TYPE The connected demux shelf. | 1.3.6.1.4.1.4253.1.3.6.1.22 | ShelfInput | read-only | mandatory |
| connDemuxSlot OBJECT-TYPE The connected demux slot. | 1.3.6.1.4.1.4253.1.3.6.1.23 | SlotInput | read-only | mandatory |
| connDemuxPort OBJECT-TYPE The connected demux port. | 1.3.6.1.4.1.4253.1.3.6.1.24 | INTEGER | read-only | mandatory |
| ccModelNum OBJECT-TYPE Model number of the CC card. Up to 15 characters | 1.3.6.1.4.1.4253.1.3.6.1.25 | DisplayString | read-only | mandatory |
| ccLinkITUNum OBJECT-TYPE Link ITU number of the CC card. Up to 15 characters | 1.3.6.1.4.1.4253.1.3.6.1.26 | DisplayString | read-only | mandatory |
| ccLinkWavelength OBJECT-TYPE Link Wavelength of the CC card | 1.3.6.1.4.1.4253.1.3.6.1.27 | DisplayString (SIZE(0..15)) | read-only | mandatory |
| ccLaserType OBJECT-TYPE Laser Type of the Channel Card. | 1.3.6.1.4.1.4253.1.3.6.1.28 | INTEGER {uncooled(1), cooled(2)} | read-only | mandatory |
| ccRecvDiode OBJECT-TYPE Receive Diode of the Channel Card. | 1.3.6.1.4.1.4253.1.3.6.1.29 | INTEGER {apd(1), pin(2)} | read-only | mandatory |
| ccLinkAutoDisable OBJECT-TYPE Flag to enable/disable the CPE link when the threshold value crosses the lower hysteresis limit. The default value is disable. CPE disable with CPE Rx pass through is identical to normal CPE disable with the added feature that the remote CPE Tx will be disabled if a loss of light condition is detected on the local CPE Rx. | 1.3.6.1.4.1.4253.1.3.6.1.30 | INTEGER {enable(1), disable(2), enableCpeRxPassThru(3)} | read-write | mandatory |
| ccLinkName OBJECT-TYPE Link name for fiber between the local and the remote cc card. | 1.3.6.1.4.1.4253.1.3.6.1.31 | LinkName | read-write | mandatory |
| ccCsimModule OBJECT-TYPE Whether colorSIM module is physically present, not installed or preconfigured. | 1.3.6.1.4.1.4253.1.3.6.1.32 | INTEGER {installed(1), notinstalled(2), preconfigured(3)} | read-only | mandatory |
| ccHWName OBJECT-TYPE Display Hardware name of the CC Card. | 1.3.6.1.4.1.4253.1.3.6.1.33 | CardName | read-only | mandatory |
| ccBackpackModule OBJECT-TYPE Presence of Backpack module, installed or not Installed. | 1.3.6.1.4.1.4253.1.3.6.1.34 | INTEGER {installed(1), notInstalled(2)} | read-only | mandatory |
| ccBackpackRxITUNumber OBJECT-TYPE Rx ITU number of backpack. | 1.3.6.1.4.1.4253.1.3.6.1.35 | DisplayString | read-only | mandatory |
| ccBackpackTxITUNumber OBJECT-TYPE Tx ITU number of backpack. | 1.3.6.1.4.1.4253.1.3.6.1.36 | DisplayString | read-only | mandatory |
| ccBackpackRxInsertionLoss OBJECT-TYPE Rx Insertion loss of backpack. | 1.3.6.1.4.1.4253.1.3.6.1.37 | DisplayString | read-only | mandatory |
| ccBackpackTxInsertionLoss OBJECT-TYPE Tx Insertion loss of backpack. | 1.3.6.1.4.1.4253.1.3.6.1.38 | DisplayString | read-only | mandatory |
| ccBackpackRxExpressLoss OBJECT-TYPE Rx Express loss of backpack. | 1.3.6.1.4.1.4253.1.3.6.1.39 | DisplayString | read-only | mandatory |
| ccBackpackTxExpressLoss OBJECT-TYPE Tx Express loss of backpack. | 1.3.6.1.4.1.4253.1.3.6.1.40 | DisplayString | read-only | mandatory |
| ccSwitchByShelfSlot OBJECT-TYPE Initiate manual UPSR switching by shelf and slot. | 1.3.6.1.4.1.4253.1.3.6.1.41 | DisplayString (SIZE(0..10)) | read-write | mandatory |
| ccPathID OBJECT-TYPE Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path. | 1.3.6.1.4.1.4253.1.3.6.1.42 | PathIdName | read-write | mandatory |
| ccCpeDisableThreshold OBJECT-TYPE CPE Disable Threshold (Link Rx Power) in dBm. The limit is from -32 to -8, but input should be an absolute value if using mib browser. A value of 0 in this field indicates that UPSR is not supported. This value will not take affect until ccLinkAutoDisable has been enabled. | 1.3.6.1.4.1.4253.1.3.6.1.43 | INTEGER | read-write | mandatory |
| ccCpeReEnableThreshold OBJECT-TYPE CPE Re-enable threshold (Link Rx Power) in dBm. The limit is from -31 to -7, but input should be an absolute value if using mib browser. A value of 0 in this field indicates that UPSR is not supported. This value will not take affect until ccLinkAutoDisable has been enabled. | 1.3.6.1.4.1.4253.1.3.6.1.44 | INTEGER | read-write | mandatory |
| connTxNonMuxDmuxCardType OBJECT-TYPE Type of module connected to Tx port of OCM. | 1.3.6.1.4.1.4253.1.3.6.1.45 | CardType | read-only | mandatory |
| connTxNonMuxDmuxPort OBJECT-TYPE Conn port for CC's Tx port.Possible values based on card types that can connect to OCM are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCMU/OCMITU/MCMT1/MCME1/OCM10G/OCM10G: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=15501590/, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. | 1.3.6.1.4.1.4253.1.3.6.1.46 | INTEGER | read-only | mandatory |
| connTxNonMuxDmuxShelf OBJECT-TYPE The shelf the card conn to Tx port of OCM. Valid values are: 1 to 10. | 1.3.6.1.4.1.4253.1.3.6.1.47 | ShelfInput | read-only | mandatory |
| connTxNonMuxDmuxSlot OBJECT-TYPE The slot within the shelf the card conn to Tx port of OCM. | 1.3.6.1.4.1.4253.1.3.6.1.48 | SlotInput | read-only | mandatory |
| connRxNonMuxDmuxCardType OBJECT-TYPE Type of module connected to Rx port of OCM. | 1.3.6.1.4.1.4253.1.3.6.1.49 | CardType | read-only | mandatory |
| connRxNonMuxDmuxPort OBJECT-TYPE Conn port for CC's Rx port.Possible values based on card types that can connect to OCM are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCMU/OCMITU/MCMT1/MCME1/OCM10G/OCM10G: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=15501590/, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. | 1.3.6.1.4.1.4253.1.3.6.1.50 | INTEGER | read-only | mandatory |
| connRxNonMuxDmuxShelf OBJECT-TYPE The shelf the card conn to Rx port of OCM. Valid values are: 1 to 10. | 1.3.6.1.4.1.4253.1.3.6.1.51 | ShelfInput | read-only | mandatory |
| connRxNonMuxDmuxSlot OBJECT-TYPE The slot within the shelf the card conn to Rx port of OCM. | 1.3.6.1.4.1.4253.1.3.6.1.52 | SlotInput | read-only | mandatory |
| ccUpsrMode OBJECT-TYPE UPSR mode for CC card: primary or backup. If not in upsr configuration, value is na. This value will not take affect until ccLinkAutoDisable has been enabled. | 1.3.6.1.4.1.4253.1.3.6.1.53 | INTEGER {primary(1), backup(2), na(3)} | read-write | mandatory |
| ccPairShelf OBJECT-TYPE The shelf of other CC card in pair. | 1.3.6.1.4.1.4253.1.3.6.1.54 | INTEGER | read-write | mandatory |
| ccPairSlot OBJECT-TYPE The slot of other CC card in pair. Input 0 to unpair OCMs and delete RSM connections if any. | 1.3.6.1.4.1.4253.1.3.6.1.55 | INTEGER | read-write | mandatory |
| ccAdminState OBJECT-TYPE Administrative control over that cc card. Default value is enable. When disabled, no alarms/events gets generated. For remote CC, the default value is disabled | 1.3.6.1.4.1.4253.1.3.6.1.56 | INTEGER {disable(1), enable(2), na(3)} | read-write | mandatory |
| ccRegenPairShelf OBJECT-TYPE The shelf of other CC card in OCM regeneration pair. This value will not take affect until ccLinkAutoDisable has been enabled. | 1.3.6.1.4.1.4253.1.3.6.1.57 | INTEGER | read-write | mandatory |
| ccRegenPairSlot OBJECT-TYPE The slot of other CC card in OCM regeneration pair. Input 0 to unpair OCMs involved. This value will not take affect until ccLinkAutoDisable has been enabled. | 1.3.6.1.4.1.4253.1.3.6.1.58 | INTEGER | read-write | mandatory |
| ccCleiNum OBJECT-TYPE CLEI number of the CC Card. | 1.3.6.1.4.1.4253.1.3.6.1.59 | DisplayString | read-only | mandatory |
| connCpeTxMcmescShelf OBJECT-TYPE The connected MCMESC shelf. | 1.3.6.1.4.1.4253.1.3.6.1.60 | ShelfInput | read-only | mandatory |
| connCpeTxMcmescSlot OBJECT-TYPE The connected MCMESC slot. | 1.3.6.1.4.1.4253.1.3.6.1.61 | SlotInput | read-only | mandatory |
| connCpeTxMcmescPort OBJECT-TYPE The connected MCMESC port. 1=Link Tx, 2=Link Rx. | 1.3.6.1.4.1.4253.1.3.6.1.62 | INTEGER {linktx(1), linkrx(2)} | read-only | mandatory |
| connCpeRxMcmescShelf OBJECT-TYPE The connected MCMESC shelf. | 1.3.6.1.4.1.4253.1.3.6.1.63 | ShelfInput | read-only | mandatory |
| connCpeRxMcmescSlot OBJECT-TYPE The connected MCMESC slot. | 1.3.6.1.4.1.4253.1.3.6.1.64 | SlotInput | read-only | mandatory |
| connCpeRxMcmescPort OBJECT-TYPE The connected MCMESC port. 1=Link Tx, 2=Link Rx. | 1.3.6.1.4.1.4253.1.3.6.1.65 | INTEGER {linktx(1), linkrx(2)} | read-only | mandatory |
| ccNumPorts OBJECT-TYPE Total port numbers on each CC card. | 1.3.6.1.4.1.4253.1.3.6.1.66 | INTEGER | read-only | mandatory |
| mux OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.4 | |||
| muxBootPromVer OBJECT-TYPE The current version string of the Mux Boot PROM code | 1.3.6.1.4.1.4253.1.4.1 | VersionString | not-accessible | mandatory |
| muxROMSize OBJECT-TYPE Total Size of the ROM in Kilobyes | 1.3.6.1.4.1.4253.1.4.2 | INTEGER (0..1024) | not-accessible | mandatory |
| muxNumSubDiv OBJECT-TYPE Number of the subdivisions of the ROM. | 1.3.6.1.4.1.4253.1.4.3 | INTEGER (0..20) | not-accessible | mandatory |
| muxSubDivTable OBJECT-TYPE This table represents the number of sub divisions and the size of each subdivision in ROM memory | 1.3.6.1.4.1.4253.1.4.4 | not-accessible | mandatory | |
| muxSubDivEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.4.4.1 | not-accessible | mandatory | |
| muxSubDivIndex OBJECT-TYPE Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM. | 1.3.6.1.4.1.4253.1.4.4.1.1 | INTEGER (0..20) | not-accessible | mandatory |
| muxSubDivDescr OBJECT-TYPE Display Name of each Sub Division in ROM | 1.3.6.1.4.1.4253.1.4.4.1.2 | DisplayString (SIZE(0..20)) | not-accessible | mandatory |
| muxSubDivSize OBJECT-TYPE Size of each sub division in ROM in kilobytes | 1.3.6.1.4.1.4253.1.4.4.1.3 | INTEGER (0..1024) | not-accessible | mandatory |
| muxSubDivOffset OBJECT-TYPE Starting address of each sub division in the ROM in HEX notation. | 1.3.6.1.4.1.4253.1.4.4.1.4 | OCTET STRING (SIZE(0..8)) | not-accessible | mandatory |
| muxNumber OBJECT-TYPE Number of MUX rows in the following table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.4.5 | INTEGER | read-only | mandatory |
| muxTable OBJECT-TYPE This table represents the information for each MUX card | 1.3.6.1.4.1.4253.1.4.6 | not-accessible | mandatory | |
| muxEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.4.6.1 | not-accessible | mandatory | |
| muxCardLocation OBJECT-TYPE Location of the module. Valid values are: Local in the same chassis, or remote to this chassis | 1.3.6.1.4.1.4253.1.4.6.1.1 | CardLocation | read-only | mandatory |
| muxCardShelf OBJECT-TYPE The shelf the card is in. | 1.3.6.1.4.1.4253.1.4.6.1.2 | CardShelf | read-only | mandatory |
| muxCardSlot OBJECT-TYPE The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.4.6.1.3 | SlotInput | read-write | mandatory |
| muxModelNum OBJECT-TYPE Model number for module. | 1.3.6.1.4.1.4253.1.4.6.1.4 | DisplayString | read-only | mandatory |
| muxMfgDate OBJECT-TYPE Date and Time of manufacturing of the module | 1.3.6.1.4.1.4253.1.4.6.1.5 | DateAndTime | not-accessible | mandatory |
| muxSerialNum OBJECT-TYPE Serial # of the module. | 1.3.6.1.4.1.4253.1.4.6.1.6 | SerialString | read-only | mandatory |
| muxModelType OBJECT-TYPE Model type of the module | 1.3.6.1.4.1.4253.1.4.6.1.7 | CardType | read-only | mandatory |
| muxName OBJECT-TYPE User configurable name of the module | 1.3.6.1.4.1.4253.1.4.6.1.8 | CardName | read-write | mandatory |
| muxFWVersionID OBJECT-TYPE The current version string of the FW code | 1.3.6.1.4.1.4253.1.4.6.1.9 | VersionString | read-only | mandatory |
| muxSetState OBJECT-TYPE Instruct the mux to do a warmboot. A get on this will always return an other. | 1.3.6.1.4.1.4253.1.4.6.1.10 | RebootType | read-write | mandatory |
| muxNumPorts OBJECT-TYPE Total port numbers on each MUX card. Should be six | 1.3.6.1.4.1.4253.1.4.6.1.11 | INTEGER | read-only | mandatory |
| muxUpgradeFlag OBJECT-TYPE The MUX card's status is upgradable or not. | 1.3.6.1.4.1.4253.1.4.6.1.12 | INTEGER {upgradable(1), notUpgradable(2)} | read-only | mandatory |
| muxHWName OBJECT-TYPE Display Hardware name of the mux/dmux Card. | 1.3.6.1.4.1.4253.1.4.6.1.13 | CardName | read-only | mandatory |
| muxPathID OBJECT-TYPE Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path. | 1.3.6.1.4.1.4253.1.4.6.1.14 | PathIdName | read-write | mandatory |
| muxAdminState OBJECT-TYPE Administrative control over that mux card. Default value is enable. When disabled, no alarms/events gets generated. | 1.3.6.1.4.1.4253.1.4.6.1.15 | INTEGER {disable(1), enable(2), na(3)} | read-write | mandatory |
| muxCleiNum OBJECT-TYPE CLEI number of the mux/dmux Card. | 1.3.6.1.4.1.4253.1.4.6.1.16 | DisplayString | read-only | mandatory |
| muxChannelSpacing OBJECT-TYPE ITU channel spacing for the mux/demux card. Only valid for MD100-40 and BD4 Modules. | 1.3.6.1.4.1.4253.1.4.6.1.17 | INTEGER | read-only | mandatory |
| muxStartItu OBJECT-TYPE First ITU channel supported by the module. Only valid for MD100-40 and BD4 Modules. | 1.3.6.1.4.1.4253.1.4.6.1.18 | INTEGER | read-only | mandatory |
| muxEndItu OBJECT-TYPE Last ITU channel supported by the module. Only valid for MD100-40 and BD4 Modules. | 1.3.6.1.4.1.4253.1.4.6.1.19 | INTEGER | read-only | mandatory |
| muxChannelsPerBand OBJECT-TYPE Number of channels per optical band supported by the module. Only valid for BD-4 and MD100-40 module. | 1.3.6.1.4.1.4253.1.4.6.1.20 | INTEGER | read-only | mandatory |
| muxBands OBJECT-TYPE Number of bands supported by the module. Only valid for BD-4 and MD100-40 module. | 1.3.6.1.4.1.4253.1.4.6.1.21 | INTEGER | read-only | mandatory |
| muxPortNumber OBJECT-TYPE Number of MUX's port rows in the following table. This number is automatically updated whenever a new row is added to the table below.Basically a product of # of mux cards and # of ports on each card. Hence it would have a value of 6, 12, 18 etc.. | 1.3.6.1.4.1.4253.1.4.7 | INTEGER | read-only | mandatory |
| muxPortTable OBJECT-TYPE This table represents the information for each MUX card's port. | 1.3.6.1.4.1.4253.1.4.8 | not-accessible | mandatory | |
| muxPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.4.8.1 | not-accessible | mandatory | |
| muxPortCardLocation OBJECT-TYPE Location of the MUX's port. Valid values are: Local in the same chassis, or remote to this chassis | 1.3.6.1.4.1.4253.1.4.8.1.1 | CardLocation | read-only | mandatory |
| muxPortCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.4.8.1.2 | CardShelf | read-only | mandatory |
| muxPortCardSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.1.4.8.1.3 | SlotInput | read-only | mandatory |
| muxPortIndex OBJECT-TYPE Port's index. Ports 1 through 4 can be use for connection with OCM family or MCMT1/MCME1 only. | 1.3.6.1.4.1.4253.1.4.8.1.4 | INTEGER | read-only | mandatory |
| muxWavelength OBJECT-TYPE Port's wavelength: either ITU number or actual wavelength in nm. Supported by all Mux modules except MD100-40 & BD4. | 1.3.6.1.4.1.4253.1.4.8.1.5 | INTEGER | read-only | mandatory |
| muxInsertLoss OBJECT-TYPE Mux Port insertion Loss range. Supported by all Mux modules except MD100-40 & BD4. | 1.3.6.1.4.1.4253.1.4.8.1.6 | DisplayString | read-only | mandatory |
| muxConnCardType OBJECT-TYPE Module type connected to mux port. Supported by all Mux modules except MD100-40 & BD4. | 1.3.6.1.4.1.4253.1.4.8.1.7 | CardType | read-write | mandatory |
| muxConnLocation OBJECT-TYPE The chassis's location of the card conn to. Supported by all Mux modules except MD100-40 & BD4. | 1.3.6.1.4.1.4253.1.4.8.1.8 | CardLocation | read-write | mandatory |
| muxConnShelf OBJECT-TYPE The shelf the card conn to. Valid values are: 1 to 2. Supported by all Mux modules except MD100-40 & BD4. | 1.3.6.1.4.1.4253.1.4.8.1.9 | ShelfInput | read-write | mandatory |
| muxConnSlot OBJECT-TYPE The slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0. Supported by all Mux modules except MD100-40 & BD4. | 1.3.6.1.4.1.4253.1.4.8.1.10 | SlotInput | read-write | mandatory |
| muxConnPort OBJECT-TYPE Conn port for MUX/DMUX's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. Entry supported by all Mux modules except MD100-40 & BD4. | 1.3.6.1.4.1.4253.1.4.8.1.11 | INTEGER | read-write | mandatory |
| muxPortType OBJECT-TYPE Type of the MUX's port. Supported by all Mux modules except MD100-40 & BD4. | 1.3.6.1.4.1.4253.1.4.8.1.12 | INTEGER {mux(1), demux(2)} | read-only | mandatory |
| muxConnChassisID OBJECT-TYPE Chassis ID of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the chassis Id of the local node. Supported by all Mux modules except MD100-40 & BD4. | 1.3.6.1.4.1.4253.1.4.8.1.13 | DisplayString (SIZE(0..16)) | read-write | mandatory |
| muxConnSystemName OBJECT-TYPE System Name of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the sysetem name of the local node. Supported by all Mux modules except MD100-40 & BD4. | 1.3.6.1.4.1.4253.1.4.8.1.14 | DisplayString (SIZE(0..32)) | read-write | mandatory |
| muxConnIpAddress OBJECT-TYPE IpAddress of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the IP address of the node. Supported by all Mux modules except MD100-40 & BD4. | 1.3.6.1.4.1.4253.1.4.8.1.15 | IpAddress | read-write | mandatory |
| muxPortAvgInsertionLoss OBJECT-TYPE Average port insertion loss for the port category. Valid only for MD100-40 & BD4 modules. | 1.3.6.1.4.1.4253.1.4.8.1.16 | DisplayString | read-only | mandatory |
| muxPortMaxInsertionLoss OBJECT-TYPE Maximum port insertion loss for the port category. Valid only for MD100-40 & BD4 modules. | 1.3.6.1.4.1.4253.1.4.8.1.17 | DisplayString | read-only | mandatory |
| muxPortTapRatio OBJECT-TYPE Tap ratio for the port category. Valid only for MD100-40 & BD4 modules. | 1.3.6.1.4.1.4253.1.4.8.1.18 | DisplayString | read-only | mandatory |
| ps OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.5 | |||
| psNumber OBJECT-TYPE Number of PS (power supply) rows in the following table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.5.1 | INTEGER | read-only | mandatory |
| psTable OBJECT-TYPE This table represents the information for each PS module. | 1.3.6.1.4.1.4253.1.5.2 | not-accessible | mandatory | |
| psEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.5.2.1 | not-accessible | mandatory | |
| psID OBJECT-TYPE The module ID the ps module is in. Valid values are: 1 to 4 | 1.3.6.1.4.1.4253.1.5.2.1.1 | INTEGER (1..4) | not-accessible | mandatory |
| psMode OBJECT-TYPE Mode of the PS module. Valid values are: active or standby | 1.3.6.1.4.1.4253.1.5.2.1.2 | RedundancyMode | not-accessible | mandatory |
| psMfgDate OBJECT-TYPE Date and Time of manufacturing of the PS module. | 1.3.6.1.4.1.4253.1.5.2.1.3 | DateAndTime | not-accessible | mandatory |
| psSerialNum OBJECT-TYPE Serial # of the PS module. Not Supported Yet. | 1.3.6.1.4.1.4253.1.5.2.1.4 | SerialString | not-accessible | mandatory |
| psModelType OBJECT-TYPE Model type of the PS module. Up to 10 characters. Not Supported Yet. | 1.3.6.1.4.1.4253.1.5.2.1.5 | ModelString | not-accessible | mandatory |
| download OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.6 | |||
| dlFtpTable OBJECT-TYPE This table represents the information for each FTP server | 1.3.6.1.4.1.4253.1.6.1 | not-accessible | mandatory | |
| dlFtpEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.6.1.1 | not-accessible | mandatory | |
| dlFtpIp OBJECT-TYPE The IP address of the FTP server. | 1.3.6.1.4.1.4253.1.6.1.1.1 | IpAddress | read-write | mandatory |
| dlFtpLogonID OBJECT-TYPE The FTP user ID for this FTP server. Up to 15 chars. | 1.3.6.1.4.1.4253.1.6.1.1.2 | LogonID | read-write | mandatory |
| dlFtpPasswd OBJECT-TYPE Password for the above FTP Logon ID. This password is NOT hashed. Proper security access is required to set and view this element. Most FTP connections, however, are using anonymous logon ID with no special password requirements. | 1.3.6.1.4.1.4253.1.6.1.1.3 | DisplayString (SIZE(0..20)) | read-write | mandatory |
| dlFtpMode OBJECT-TYPE FTP server modes. The choices are: active or passive, active may be necessary for users behind a firewall. | 1.3.6.1.4.1.4253.1.6.1.1.4 | FtpMode | read-write | mandatory |
| dlFtpPort OBJECT-TYPE FTP port. This port is used in conjunction with the FTP IP address for establishing a connection to the FTP server. Any valid IP port may be entered. Setting this element to zero (0) will cause the standard FTP port (21) to be used. | 1.3.6.1.4.1.4253.1.6.1.1.5 | INTEGER (0..65535) | read-write | mandatory |
| dlPreQualTable OBJECT-TYPE This table represents the information for each PreQual table. | 1.3.6.1.4.1.4253.1.6.2 | not-accessible | mandatory | |
| dlPreQualEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.6.2.1 | not-accessible | mandatory | |
| dlPreQualTypeVersion OBJECT-TYPE The Image type and version to be prequalified before downloading. The string format is : type,version. The prequal action will be taken after setting version. | 1.3.6.1.4.1.4253.1.6.2.1.1 | DisplayString (SIZE(0..42)) | read-write | mandatory |
| dlPreQualResult OBJECT-TYPE The result after comparing type and version of the selected download image with the compatibility matrix. The result is either compatible, incompatible or unknown version. (Not available at this time). The default is compatible. | 1.3.6.1.4.1.4253.1.6.2.1.2 | INTEGER {compatible(1), incompatible(2), unknown-version(3)} | read-only | mandatory |
| dlDownloadTable OBJECT-TYPE This table represents the information for download and activation. | 1.3.6.1.4.1.4253.1.6.3 | not-accessible | mandatory | |
| dlDownloadEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.6.3.1 | not-accessible | mandatory | |
| dlType OBJECT-TYPE The Image type to be downloaded or to be activated. The valid values are: all, mpms, boot, macf, mcme1, mcmesc_code, mcmt1, mpm, ocm, ocm10g, oet, osam, osam_hp/lp, rsm, upsm, uob. When choosing all, all non-mpm images are downloaded, the dlLocation should be set to local, dlShelf and dlSlot should be set to 0, dlFilename should be set to the path under which all the non-mpm images are put. When choosing mpms, mpm's two associated images, boot and mpm run code image, are downloaded, the dlLocation should be set to local, dlShelf and dlSlot should be set to active mpm's shelf and slot, dlFilename should be set to the path under which the two images are put. To MCME1/MCMT1 modules, mcm_fpag image will automatically be downloaded when mcme1 or mcmt1 is selected. | 1.3.6.1.4.1.4253.1.6.3.1.1 | DownloadType | read-write | mandatory |
| dlLocation OBJECT-TYPE The location to be downloaded or to be activated. The choices are: local, remote or both. (Only local and remote are supported at this time, LuxnOS has only local choice and is not supported yet. When dlType is set to all, only local is supported. | 1.3.6.1.4.1.4253.1.6.3.1.2 | DownloadLocation | read-write | mandatory |
| dlShelf OBJECT-TYPE The destination shelf. When dlType is set to all, dlShelf should be set to 0. | 1.3.6.1.4.1.4253.1.6.3.1.3 | DownloadShelf | read-write | mandatory |
| dlSlot OBJECT-TYPE The slot within the selected shelf. When dlType is set to all, dlSlot should be set to 0. | 1.3.6.1.4.1.4253.1.6.3.1.4 | DownloadSlot | read-write | mandatory |
| dlFilename OBJECT-TYPE The filename and path of the file to be downloaded -up to 255 characters. When dlType is set to all, the dlFilename field should be set to the path of the directory where the non-mpm images are stored. When dlType is set to mpms, the dlFilename field should be set to the path of the directory where the boot and mpm images are stored. The download action (imageupdate) will be taken after setting the dlFilename field. | 1.3.6.1.4.1.4253.1.6.3.1.5 | DisplayString (SIZE(0..255)) | read-write | mandatory |
| dlActivate OBJECT-TYPE Activate the backup image at the selected location. To MCMESC, no, activateBackupFirmware, activateBackupFPGA and activateBackupFirmwareAndFPGA are applicable. To MCMT1/MCME1, no and activateBackupFirmwareAndFPGA are applicable. To other modules, no and activateBackupFirmware are applicable. When choosing activateForAllLineCards, the dlShelf and dlSlot sholud be set to 0. | 1.3.6.1.4.1.4253.1.6.3.1.6 | INTEGER {no(1), activateBackupFirmware(2), activateBackupFPGA(3), activateBackupFirmwareAndFPGA(4), activateForAllLineCards(5)} | read-write | mandatory |
| dlExportType OBJECT-TYPE The image indicated by dlType is to be exported to the dlFilename using FTP. Ths element is reset to none(1) after each export. | 1.3.6.1.4.1.4253.1.6.3.1.7 | INTEGER {import(1), export(2)} | read-write | mandatory |
| dlOSTable OBJECT-TYPE This table represents the information for LuxnOS table. | 1.3.6.1.4.1.4253.1.6.4 | not-accessible | mandatory | |
| dlOSEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.6.4.1 | not-accessible | mandatory | |
| dlOSIndex OBJECT-TYPE The Integer ID for each LuxnOS. | 1.3.6.1.4.1.4253.1.6.4.1.1 | INTEGER (1..2) | not-accessible | mandatory |
| dlOSVersion OBJECT-TYPE Display the LuxnOS version. | 1.3.6.1.4.1.4253.1.6.4.1.2 | VersionString | not-accessible | mandatory |
| dlOSState OBJECT-TYPE Display the LuxnOS state: operating(1) is the current operating LuxnOS, backup(2)is the backup LuxnOS. | 1.3.6.1.4.1.4253.1.6.4.1.3 | OSState | not-accessible | mandatory |
| dlOSRelDate OBJECT-TYPE Display the release date of the LuxnOS. | 1.3.6.1.4.1.4253.1.6.4.1.4 | ReleaseDate | not-accessible | mandatory |
| dlUpdateOS OBJECT-TYPE Display and select Update LuxnOS Mode: toggle(1) to toggle between operating and backup LuxnOS, revert(2) to copy LuxnOS from the backup to the operating area. The action will be taken after setting UpdateOS . | 1.3.6.1.4.1.4253.1.6.5 | UpdateOSMode | not-accessible | mandatory |
| fadm OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.7 | |||
| fadmBootPromVer OBJECT-TYPE The current version string of the OADM Boot PROM code | 1.3.6.1.4.1.4253.1.7.1 | VersionString | not-accessible | mandatory |
| fadmROMSize OBJECT-TYPE Total Size of the ROM in Kilobyes | 1.3.6.1.4.1.4253.1.7.2 | INTEGER (1..1024) | not-accessible | mandatory |
| fadmNumSubDiv OBJECT-TYPE Number of the subdivisions of the ROM. | 1.3.6.1.4.1.4253.1.7.3 | INTEGER (1..20) | not-accessible | mandatory |
| fadmSubDivTable OBJECT-TYPE This table represents the number of sub divisions and the size of each subdivision in ROM memory | 1.3.6.1.4.1.4253.1.7.4 | not-accessible | mandatory | |
| fadmSubDivEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.7.4.1 | not-accessible | mandatory | |
| fadmSubDivIndex OBJECT-TYPE Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM. | 1.3.6.1.4.1.4253.1.7.4.1.1 | INTEGER (1..20) | not-accessible | mandatory |
| fadmSubDivDescr OBJECT-TYPE Display Name of each Sub Division in ROM | 1.3.6.1.4.1.4253.1.7.4.1.2 | DisplayString (SIZE(0..20)) | not-accessible | mandatory |
| fadmSubDivSize OBJECT-TYPE Size of each sub division in ROM in kilobytes | 1.3.6.1.4.1.4253.1.7.4.1.3 | INTEGER (1..1024) | not-accessible | mandatory |
| fadmSubDivOffset OBJECT-TYPE Starting address of each sub division in the ROM in HEX notation. | 1.3.6.1.4.1.4253.1.7.4.1.4 | OCTET STRING (SIZE(0..8)) | not-accessible | mandatory |
| fadmNumber OBJECT-TYPE Number of FADM rows in the following table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.7.5 | INTEGER | read-only | mandatory |
| fadmTable OBJECT-TYPE This table represents the information for each OADM module | 1.3.6.1.4.1.4253.1.7.6 | not-accessible | mandatory | |
| fadmEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.7.6.1 | not-accessible | mandatory | |
| fadmCardLocation OBJECT-TYPE Location of the FADM Module. | 1.3.6.1.4.1.4253.1.7.6.1.1 | CardLocation | read-only | mandatory |
| fadmCardShelf OBJECT-TYPE The shelf of the Module is in. Valid values are: 1, 2 or 3 depending on the chassis type. | 1.3.6.1.4.1.4253.1.7.6.1.2 | CardShelf | read-only | mandatory |
| fadmCardSlot OBJECT-TYPE The slot within the shelf the module is in. The range of valid values range from 1 through 21 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.7.6.1.3 | SlotInput | read-write | mandatory |
| fadmMfgDate OBJECT-TYPE Date and Time of manufacturing of the FADM card | 1.3.6.1.4.1.4253.1.7.6.1.4 | DateAndTime | not-accessible | mandatory |
| fadmSerialNum OBJECT-TYPE Serial # of the FADM card. | 1.3.6.1.4.1.4253.1.7.6.1.5 | SerialString | read-only | mandatory |
| fadmModelType OBJECT-TYPE Model type of the FADM | 1.3.6.1.4.1.4253.1.7.6.1.6 | CardType | read-only | mandatory |
| fadmName OBJECT-TYPE Display (Network) name of the FADM Card | 1.3.6.1.4.1.4253.1.7.6.1.7 | CardName | read-write | mandatory |
| fadmFWVersionID OBJECT-TYPE The current version string of the FADM FW code | 1.3.6.1.4.1.4253.1.7.6.1.8 | VersionString | read-only | mandatory |
| fadmSetState OBJECT-TYPE Instruct the fadm to do a warmboot. A get on this will always return an other. | 1.3.6.1.4.1.4253.1.7.6.1.9 | RebootType | read-write | mandatory |
| fadmNumPorts OBJECT-TYPE Total port numbers of FADM module. | 1.3.6.1.4.1.4253.1.7.6.1.10 | INTEGER | read-only | mandatory |
| fadmUpgradeFlag OBJECT-TYPE The FADM module's status is upgradeable or not. | 1.3.6.1.4.1.4253.1.7.6.1.11 | INTEGER {upgradeable(1), notUpgradeable(2)} | read-only | mandatory |
| fadmModelNum OBJECT-TYPE Model # of the FADM card. Up to 15 characters | 1.3.6.1.4.1.4253.1.7.6.1.12 | DisplayString | read-only | mandatory |
| fadmITUNumber1 OBJECT-TYPE Port 1's ITU wavelength. | 1.3.6.1.4.1.4253.1.7.6.1.13 | INTEGER | read-only | mandatory |
| fadmITUNumber2 OBJECT-TYPE | 1.3.6.1.4.1.4253.1.7.6.1.14 | INTEGER | read-only | mandatory |
| fadmInsertionLoss1 OBJECT-TYPE Port 1's insertion loss in dB. | 1.3.6.1.4.1.4253.1.7.6.1.15 | DisplayString | read-only | mandatory |
| fadmInsertionLoss2 OBJECT-TYPE | 1.3.6.1.4.1.4253.1.7.6.1.16 | DisplayString | not-accessible | mandatory |
| fadmExpressLoss OBJECT-TYPE Internal express port's insertion loss in dB. | 1.3.6.1.4.1.4253.1.7.6.1.17 | DisplayString | read-only | mandatory |
| fadmHWName OBJECT-TYPE Display Hardware name of the FADM Card. | 1.3.6.1.4.1.4253.1.7.6.1.18 | CardName | read-only | mandatory |
| fadmPathID OBJECT-TYPE Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path. | 1.3.6.1.4.1.4253.1.7.6.1.19 | PathIdName | read-write | mandatory |
| fadmAdminState OBJECT-TYPE Administrative control over that fadm card. Default value is enable. When disabled, no alarms/events gets generated. | 1.3.6.1.4.1.4253.1.7.6.1.20 | INTEGER {disable(1), enable(2), na(3)} | read-write | mandatory |
| fadmCleiNum OBJECT-TYPE CLEI number of the fadm Card. | 1.3.6.1.4.1.4253.1.7.6.1.21 | DisplayString | read-only | mandatory |
| fadmBand OBJECT-TYPE Optical band supported by the module. Valid only for BP-5 and BP-10 modules. | 1.3.6.1.4.1.4253.1.7.6.1.22 | DisplayString | read-only | mandatory |
| fadmChannelsPerBand OBJECT-TYPE Number of channels per optical band supported by the module. Only valid for BP-5 and BP-10module. | 1.3.6.1.4.1.4253.1.7.6.1.23 | INTEGER | read-only | mandatory |
| fadmStartItu OBJECT-TYPE First ITU channel supported by the module. Valid only for BP-5 and BP-10 modules. | 1.3.6.1.4.1.4253.1.7.6.1.24 | INTEGER | read-only | mandatory |
| fadmEndItu OBJECT-TYPE Last ITU channel supported by the module. Valid only for BP-5 and BP-10 modules. | 1.3.6.1.4.1.4253.1.7.6.1.25 | INTEGER | read-only | mandatory |
| fadmPortTable OBJECT-TYPE This table represents the physical connection for each FADM card's port. | 1.3.6.1.4.1.4253.1.7.7 | not-accessible | mandatory | |
| fadmPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.7.7.1 | not-accessible | mandatory | |
| fadmPortCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.7.7.1.1 | CardShelf | read-only | mandatory |
| fadmPortCardSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.1.7.7.1.2 | SlotInput | read-only | mandatory |
| fadmPortType OBJECT-TYPE Type of the FADM port. The order is CLI compatible. For FADM model type, the ports are listed on the left column | 1.3.6.1.4.1.4253.1.7.7.1.3 | INTEGER {connATx-AToD(1), connARx-EXP(2), localTx-Local(3), localRx-Rx(4), connBTx(5), connBRx(6)} | read-only | mandatory |
| fadmConnLocation OBJECT-TYPE The chassis's location of the card conn to. | 1.3.6.1.4.1.4253.1.7.7.1.4 | CardLocation | read-write | mandatory |
| fadmConnIpAddress OBJECT-TYPE IpAddress of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the IP address of the node | 1.3.6.1.4.1.4253.1.7.7.1.5 | IpAddress | read-write | mandatory |
| fadmConnChassisID OBJECT-TYPE Chassis ID of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the chassis Id of the local node | 1.3.6.1.4.1.4253.1.7.7.1.6 | DisplayString (SIZE(0..16)) | read-write | mandatory |
| fadmConnSystemName OBJECT-TYPE System Name of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the sysetem name of the local node. | 1.3.6.1.4.1.4253.1.7.7.1.7 | DisplayString (SIZE(0..32)) | read-write | mandatory |
| fadmConnCardType OBJECT-TYPE Module type connected to fadm port. | 1.3.6.1.4.1.4253.1.7.7.1.8 | CardType | read-write | mandatory |
| fadmConnPort OBJECT-TYPE Conn port for FADM's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. | 1.3.6.1.4.1.4253.1.7.7.1.9 | INTEGER | read-write | mandatory |
| fadmConnShelf OBJECT-TYPE The shelf the card conn to. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.7.7.1.10 | ShelfInput | read-write | mandatory |
| fadmConnSlot OBJECT-TYPE The slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0. | 1.3.6.1.4.1.4253.1.7.7.1.11 | SlotInput | read-write | mandatory |
| oppm OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.8 | |||
| oppmBootPromVer OBJECT-TYPE The current version string of the oppm Boot PROM code | 1.3.6.1.4.1.4253.1.8.1 | VersionString | not-accessible | mandatory |
| oppmROMSize OBJECT-TYPE Total Size of the ROM in Kilobyes | 1.3.6.1.4.1.4253.1.8.2 | INTEGER (0..1024) | not-accessible | mandatory |
| oppmNumSubDiv OBJECT-TYPE Number of the subdivisions of the ROM. | 1.3.6.1.4.1.4253.1.8.3 | INTEGER (0..20) | not-accessible | mandatory |
| oppmSubDivTable OBJECT-TYPE This table represents the number of sub divisions and the size of each subdivision in ROM memory | 1.3.6.1.4.1.4253.1.8.4 | not-accessible | mandatory | |
| oppmSubDivEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.8.4.1 | not-accessible | mandatory | |
| oppmSubDivIndex OBJECT-TYPE Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM. | 1.3.6.1.4.1.4253.1.8.4.1.1 | INTEGER (0..20) | not-accessible | mandatory |
| oppmSubDivDescr OBJECT-TYPE Display Name of each Sub Division in ROM | 1.3.6.1.4.1.4253.1.8.4.1.2 | DisplayString (SIZE(0..20)) | not-accessible | mandatory |
| oppmSubDivSize OBJECT-TYPE Size of each sub division in ROM in kilobytes | 1.3.6.1.4.1.4253.1.8.4.1.3 | INTEGER (0..1024) | not-accessible | mandatory |
| oppmSubDivOffset OBJECT-TYPE Starting address of each sub division in the ROM in HEX notation. | 1.3.6.1.4.1.4253.1.8.4.1.4 | OCTET STRING (SIZE(0..8)) | not-accessible | mandatory |
| oppmNumber OBJECT-TYPE Number of OPPM rows in the following table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.8.5 | INTEGER | not-accessible | mandatory |
| oppmTable OBJECT-TYPE This table represents the information for each OPPM card | 1.3.6.1.4.1.4253.1.8.6 | not-accessible | mandatory | |
| oppmEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.8.6.1 | not-accessible | mandatory | |
| oppmCardLocation OBJECT-TYPE Location of the OPPM card. Valid values are: Local in the same chassis, or remote to this chassis | 1.3.6.1.4.1.4253.1.8.6.1.1 | CardLocation | not-accessible | mandatory |
| oppmCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2 | 1.3.6.1.4.1.4253.1.8.6.1.2 | CardShelf | not-accessible | mandatory |
| oppmCardSlot OBJECT-TYPE The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.8.6.1.3 | SlotInput | not-accessible | mandatory |
| oppmModelNum OBJECT-TYPE Oppm's model number. | 1.3.6.1.4.1.4253.1.8.6.1.4 | DisplayString | not-accessible | mandatory |
| oppmMfgDate OBJECT-TYPE Date and Time of manufacturing of the OPPM card | 1.3.6.1.4.1.4253.1.8.6.1.5 | DateAndTime | not-accessible | mandatory |
| oppmSerialNum OBJECT-TYPE Serial # of the OPPM card. | 1.3.6.1.4.1.4253.1.8.6.1.6 | SerialString | not-accessible | mandatory |
| oppmModelType OBJECT-TYPE Model type of the OPPM | 1.3.6.1.4.1.4253.1.8.6.1.7 | CardType | not-accessible | mandatory |
| oppmName OBJECT-TYPE Display (Network) name of the OPPM Card | 1.3.6.1.4.1.4253.1.8.6.1.8 | CardName | not-accessible | mandatory |
| oppmFWVersionID OBJECT-TYPE The current version string of the OPPM FW code | 1.3.6.1.4.1.4253.1.8.6.1.9 | VersionString | not-accessible | mandatory |
| oppmSetState OBJECT-TYPE Instruct the oppm to do a warmboot. A get on this will always return an other. | 1.3.6.1.4.1.4253.1.8.6.1.10 | RebootType | not-accessible | mandatory |
| oppmTxInsertLoss OBJECT-TYPE Transmit insertion loss. | 1.3.6.1.4.1.4253.1.8.6.1.12 | DisplayString | not-accessible | mandatory |
| oppmRxInsertLoss OBJECT-TYPE Receive insertion loss. | 1.3.6.1.4.1.4253.1.8.6.1.13 | DisplayString | not-accessible | mandatory |
| oppmUpgradeFlag OBJECT-TYPE The oppm card's status is upgradable or not. | 1.3.6.1.4.1.4253.1.8.6.1.14 | INTEGER {upgradable(1), notUpgradable(2)} | not-accessible | mandatory |
| oppmSwitch OBJECT-TYPE instruct the OPPM to take on an action, such as: switch to link A or link B A get would alway return other(1). | 1.3.6.1.4.1.4253.1.8.6.1.15 | INTEGER {other(1), switchToLinkA(2), switchToLinkB(3), toggle(4), enableAutoSwitch(6)} | not-accessible | mandatory |
| oppmMarginForSwitch OBJECT-TYPE Configurable switching margin in dB for protection switch to occur. | 1.3.6.1.4.1.4253.1.8.6.1.16 | INTEGER (5..15) | not-accessible | mandatory |
| oppmHighAlarmMargin OBJECT-TYPE High alarm margin for input signal strength displayed in dB unit | 1.3.6.1.4.1.4253.1.8.6.1.17 | INTEGER | not-accessible | mandatory |
| oppmConfigCommit OBJECT-TYPE This allows the current module configuration, such as oppmMarginForSwitch, to be stored in permanent storage. | 1.3.6.1.4.1.4253.1.8.6.1.18 | INTEGER {other(1), save(2)} | not-accessible | mandatory |
| oppmHWName OBJECT-TYPE Display Hardware name of the OPPM Card. | 1.3.6.1.4.1.4253.1.8.6.1.19 | CardName | not-accessible | mandatory |
| oppmLinkAPathID OBJECT-TYPE Oppmm LinkA Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path. | 1.3.6.1.4.1.4253.1.8.6.1.20 | PathIdName | not-accessible | mandatory |
| oppmLinkBPathID OBJECT-TYPE Oppm LinkB Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path. | 1.3.6.1.4.1.4253.1.8.6.1.21 | PathIdName | not-accessible | mandatory |
| oppmAdminState OBJECT-TYPE Administrative control over that oppm card. Default value is enable. When disabled, no alarms/events gets generated. | 1.3.6.1.4.1.4253.1.8.6.1.22 | INTEGER {disable(1), enable(2), na(3)} | not-accessible | mandatory |
| oppmCleiNum OBJECT-TYPE CLEI number of the oppm Card. | 1.3.6.1.4.1.4253.1.8.6.1.23 | DisplayString | not-accessible | mandatory |
| oppmSwitchState OBJECT-TYPE The switching state. Switching state may be either auto or forced. The auto state means automatic switching is enabled. Forced state means swithcing is disabled and has been forced to the current active link. | 1.3.6.1.4.1.4253.1.8.6.1.24 | INTEGER {auto(1), forced(2)} | not-accessible | mandatory |
| oppmPortTable OBJECT-TYPE This table represents the physical connection for each OPPM card's port. | 1.3.6.1.4.1.4253.1.8.7 | not-accessible | mandatory | |
| oppmPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.8.7.1 | not-accessible | mandatory | |
| oppmPortCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.8.7.1.1 | CardShelf | not-accessible | mandatory |
| oppmPortCardSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.1.8.7.1.2 | SlotInput | not-accessible | mandatory |
| oppmPortType OBJECT-TYPE Type of the OPPM's port. | 1.3.6.1.4.1.4253.1.8.7.1.3 | INTEGER {linkATx(1), linkARx(2), linkBTx(3), linkBRx(4), localTx(5), localRx(6)} | read-write | mandatory |
| oppmConnLocation OBJECT-TYPE The chassis's location of the card conn to. | 1.3.6.1.4.1.4253.1.8.7.1.4 | CardLocation | not-accessible | mandatory |
| oppmConnIpAddress OBJECT-TYPE IpAddress of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the IP address of the node | 1.3.6.1.4.1.4253.1.8.7.1.5 | IpAddress | not-accessible | mandatory |
| oppmConnChassisID OBJECT-TYPE Chassis ID of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the chassis Id of the local node | 1.3.6.1.4.1.4253.1.8.7.1.6 | DisplayString (SIZE(0..16)) | not-accessible | mandatory |
| oppmConnSystemName OBJECT-TYPE System Name of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the sysetem name of the local node. | 1.3.6.1.4.1.4253.1.8.7.1.7 | DisplayString (SIZE(0..32)) | not-accessible | mandatory |
| oppmConnCardType OBJECT-TYPE Module type connected to oppm port. | 1.3.6.1.4.1.4253.1.8.7.1.8 | CardType | not-accessible | mandatory |
| oppmConnPort OBJECT-TYPE Conn port for OPPM's port. Possible values based on card types that can connect to OPPM are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. | 1.3.6.1.4.1.4253.1.8.7.1.9 | INTEGER | not-accessible | mandatory |
| oppmConnShelf OBJECT-TYPE The shelf the card conn to. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.8.7.1.10 | ShelfInput | not-accessible | mandatory |
| oppmConnSlot OBJECT-TYPE The slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0. | 1.3.6.1.4.1.4253.1.8.7.1.11 | SlotInput | not-accessible | mandatory |
| mcm OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.9 | |||
| mcmBootPromVer OBJECT-TYPE The current version string of the mcmt1/mcme1 Boot PROM code | 1.3.6.1.4.1.4253.1.9.1 | VersionString | not-accessible | mandatory |
| mcmROMSize OBJECT-TYPE Total Size of the ROM in Kilobyes | 1.3.6.1.4.1.4253.1.9.2 | INTEGER (0..1024) | not-accessible | mandatory |
| mcmNumSubDiv OBJECT-TYPE Number of the subdivisions of the ROM. | 1.3.6.1.4.1.4253.1.9.3 | INTEGER (0..20) | not-accessible | mandatory |
| mcmSubDivTable OBJECT-TYPE This table represents the number of sub divisions and the size of each subdivision in ROM memory | 1.3.6.1.4.1.4253.1.9.4 | not-accessible | mandatory | |
| mcmSubDivEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.9.4.1 | not-accessible | mandatory | |
| mcmSubDivIndex OBJECT-TYPE Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM. | 1.3.6.1.4.1.4253.1.9.4.1.1 | INTEGER (0..20) | not-accessible | mandatory |
| mcmSubDivDescr OBJECT-TYPE Display Name of each Sub Division in ROM | 1.3.6.1.4.1.4253.1.9.4.1.2 | DisplayString (SIZE(0..20)) | not-accessible | mandatory |
| mcmSubDivSize OBJECT-TYPE Size of each sub division in ROM in kilobytes | 1.3.6.1.4.1.4253.1.9.4.1.3 | INTEGER (0..1024) | not-accessible | mandatory |
| mcmSubDivOffset OBJECT-TYPE Starting address of each sub division in the ROM in HEX notation. | 1.3.6.1.4.1.4253.1.9.4.1.4 | OCTET STRING (SIZE(0..8)) | not-accessible | mandatory |
| mcmNumber OBJECT-TYPE Number of ADM rows in the following table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.9.5 | INTEGER | read-only | mandatory |
| mcmTable OBJECT-TYPE This table represents the information for each mcmt1/mcme1 module | 1.3.6.1.4.1.4253.1.9.6 | not-accessible | mandatory | |
| mcmEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.9.6.1 | not-accessible | mandatory | |
| mcmCardLocation OBJECT-TYPE Location of the mcmt1/mcme1 Module. | 1.3.6.1.4.1.4253.1.9.6.1.1 | CardLocation | read-only | mandatory |
| mcmCardShelf OBJECT-TYPE The shelf of the mcmt1/mcme1 is in. Valid values are: 1..2 | 1.3.6.1.4.1.4253.1.9.6.1.2 | CardShelf | read-only | mandatory |
| mcmCardSlot OBJECT-TYPE The slot within the shelf the module is in. The range of valid values range from 1 through 21 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.9.6.1.3 | SlotInput | read-write | mandatory |
| mcmMfgDate OBJECT-TYPE Date and Time of calibration of the mcmt1/mcme1 card | 1.3.6.1.4.1.4253.1.9.6.1.4 | DateAndTime | read-only | mandatory |
| mcmSerialNum OBJECT-TYPE Serial # of the mcmt1/mcme1 card. | 1.3.6.1.4.1.4253.1.9.6.1.5 | SerialString | read-only | mandatory |
| mcmModelType OBJECT-TYPE Model type of the mcmt1/mcme1 | 1.3.6.1.4.1.4253.1.9.6.1.6 | CardType | read-only | mandatory |
| mcmName OBJECT-TYPE Display (Network) name of the MCMT1/MCME1 Module | 1.3.6.1.4.1.4253.1.9.6.1.7 | CardName | read-write | mandatory |
| mcmFWVersionID OBJECT-TYPE The current version string of the MCMT1/MCME1 FW code | 1.3.6.1.4.1.4253.1.9.6.1.8 | VersionString | read-only | mandatory |
| mcmAdminState OBJECT-TYPE Administrative control over that mcmt1/mcme1 card. Default value is enable. When disabled, no alarms/events gets generated. | 1.3.6.1.4.1.4253.1.9.6.1.9 | INTEGER {disable(1), enable(2), na(3)} | read-write | mandatory |
| mcmLaserTemperature OBJECT-TYPE Temperature of the Laser. Not yet supported | 1.3.6.1.4.1.4253.1.9.6.1.10 | INTEGER | not-accessible | mandatory |
| mcmBandwidth OBJECT-TYPE mcmt1/mcme1 module's line rate. | 1.3.6.1.4.1.4253.1.9.6.1.11 | INTEGER {other(1), oc3(2), oc12(3), oc48(4), gbEthernet(5), fibreChannel(6)} | not-accessible | mandatory |
| mcmSetState OBJECT-TYPE Instruct the mcmt1/mcme1 card to do either a reset or loopback. A get on this will always return an other. | 1.3.6.1.4.1.4253.1.9.6.1.12 | INTEGER {other(1), resetWithCurrentConfiguration(2), resetWithFactoryDefault(3), nearEndCardLoopback(4), networkCardLoopback(5), nearEndPort1Loopback(6), nearEndPort2Loopback(7), nearEndPort3Loopback(8), nearEndPort4Loopback(9), networkPort1Loopback(10), networkPort2Loopback(11), networkPort3Loopback(12), networkPort4Loopback(13), disableLoopback(14)} | read-write | mandatory |
| mcmNumPorts OBJECT-TYPE Total port numbers of MCMT1/MCME1 module. | 1.3.6.1.4.1.4253.1.9.6.1.13 | INTEGER | read-only | mandatory |
| mcmUpgradeFlag OBJECT-TYPE The MCMT1/MCME1 module's status is upgradable or not. | 1.3.6.1.4.1.4253.1.9.6.1.14 | INTEGER {upgradable(1), notUpgradable(2)} | read-only | mandatory |
| mcmEthernetStatus OBJECT-TYPE The MCMT1/MCME1 module's Ethernet status is down or up. | 1.3.6.1.4.1.4253.1.9.6.1.15 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| mcmTimingPort OBJECT-TYPE The MCMT1/MCME1 module's port clock src | 1.3.6.1.4.1.4253.1.9.6.1.16 | INTEGER {internal(1), link(2), t1Port1(3), t1Port2(4), t1Port3(5), t1Port4(6)} | read-only | mandatory |
| mcmModelNum OBJECT-TYPE The mcmt1/mcme1 port's model number | 1.3.6.1.4.1.4253.1.9.6.1.17 | DisplayString | read-only | mandatory |
| mcmMfgBiasCurrent OBJECT-TYPE Bias current for the optical laser. This is the preset manufacturing value | 1.3.6.1.4.1.4253.1.9.6.1.18 | INTEGER | read-only | mandatory |
| mcmMfgModulation OBJECT-TYPE The frequency modulation for the optical laser. This value is the preset manufacturing value. | 1.3.6.1.4.1.4253.1.9.6.1.19 | INTEGER | read-only | mandatory |
| mcmMfgApc OBJECT-TYPE The APC value. This value is the preset manufacturing value | 1.3.6.1.4.1.4253.1.9.6.1.20 | INTEGER | read-only | mandatory |
| mcmMfgIwmModulation OBJECT-TYPE The frequency modulation for the IWM channel. This value is the preset manufacturing value | 1.3.6.1.4.1.4253.1.9.6.1.21 | INTEGER | read-only | mandatory |
| mcmconnMuxShelf OBJECT-TYPE The connected mux shelf. | 1.3.6.1.4.1.4253.1.9.6.1.22 | ShelfInput | read-only | mandatory |
| mcmconnMuxSlot OBJECT-TYPE The connected mux slot. | 1.3.6.1.4.1.4253.1.9.6.1.23 | SlotInput | read-only | mandatory |
| mcmconnMuxPort OBJECT-TYPE The connected mux port. | 1.3.6.1.4.1.4253.1.9.6.1.24 | INTEGER | read-only | mandatory |
| mcmconnDemuxShelf OBJECT-TYPE The connected demux shelf. | 1.3.6.1.4.1.4253.1.9.6.1.25 | ShelfInput | read-only | mandatory |
| mcmconnDemuxSlot OBJECT-TYPE The connected demux slot. | 1.3.6.1.4.1.4253.1.9.6.1.26 | SlotInput | read-only | mandatory |
| mcmconnDemuxPort OBJECT-TYPE The connected demux port. | 1.3.6.1.4.1.4253.1.9.6.1.27 | INTEGER | read-only | mandatory |
| mcmTimingPriority OBJECT-TYPE The clock source priority in descending order in the format of a,b,c,d,e,f in which a through f should be replaced with 1 through 6 which has the same meaning as the options of mcmTimingPort and are repeated as follows: 0 - unknown 1 - internal 2 - link 3 - t1Port1 4 - t1Port2 5 - t1Port3 6 - t1Port4 For example, '2,5,4,6,3,1' will set the priority of the clock source with link first, followed by t1Port3, followed by t1Port2, followed by t1Port4, followed by t1Port1, followed by internal. | 1.3.6.1.4.1.4253.1.9.6.1.28 | DisplayString (SIZE(0..12)) | read-write | mandatory |
| mcmLinkName OBJECT-TYPE User configurable Link name for the connection between the local and remote MCM/MCME1 Modules | 1.3.6.1.4.1.4253.1.9.6.1.29 | LinkName | read-write | mandatory |
| mcmEthernetMode OBJECT-TYPE This allows the ethernet mode configured as auto detect, forced 10M, or forced 100M. | 1.3.6.1.4.1.4253.1.9.6.1.30 | INTEGER {auto(1), forced10M(2), forced100M(3)} | read-write | mandatory |
| mcmHWName OBJECT-TYPE Display Hardware name of the MCMT1/MCME1 Card. | 1.3.6.1.4.1.4253.1.9.6.1.31 | CardName | read-only | mandatory |
| mcmLinkWaveLength OBJECT-TYPE Link Wavelength of the MCMT1/MCME1 card | 1.3.6.1.4.1.4253.1.9.6.1.32 | DisplayString (SIZE(0..15)) | read-only | mandatory |
| mcmFpgaVersionID OBJECT-TYPE The current version string of the MCMT1/MCME1 FPGA. | 1.3.6.1.4.1.4253.1.9.6.1.33 | VersionString | read-only | mandatory |
| mcmPathID OBJECT-TYPE Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path. | 1.3.6.1.4.1.4253.1.9.6.1.34 | PathIdName | read-write | mandatory |
| mcmCleiNum OBJECT-TYPE CLEI number of the mcmt1/mcme1 Card. | 1.3.6.1.4.1.4253.1.9.6.1.35 | DisplayString | read-only | mandatory |
| mcmItuNum OBJECT-TYPE ITU number of the mcmt1/mcme1 Card. | 1.3.6.1.4.1.4253.1.9.6.1.36 | DisplayString | read-only | mandatory |
| mcmPortNumber OBJECT-TYPE Number of MCMT1/MCME1 rows in the following table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.9.7 | INTEGER | read-only | mandatory |
| mcmPortTable OBJECT-TYPE This table represents the information for each MCMT1/MCME1 module's port. | 1.3.6.1.4.1.4253.1.9.8 | not-accessible | mandatory | |
| mcmPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.9.8.1 | not-accessible | mandatory | |
| mcmPortCardLocation OBJECT-TYPE Location of the MCMT1/MCME1 port. Valid values are: Local in the same chassis, or remote to this chassis | 1.3.6.1.4.1.4253.1.9.8.1.1 | CardLocation | read-only | mandatory |
| mcmPortCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1..2. | 1.3.6.1.4.1.4253.1.9.8.1.2 | CardShelf | read-only | mandatory |
| mcmPortCardSlot OBJECT-TYPE The slot within the shelf the Module is in. Valid values are: 1 to 17 | 1.3.6.1.4.1.4253.1.9.8.1.3 | SlotInput | read-only | mandatory |
| mcmPortIndex OBJECT-TYPE Port's index. | 1.3.6.1.4.1.4253.1.9.8.1.4 | INTEGER | read-only | mandatory |
| mcmPortConnection OBJECT-TYPE Port's connection status. | 1.3.6.1.4.1.4253.1.9.8.1.5 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| mcmPortFraming OBJECT-TYPE Type of framing. esf(1) and d4(2) are for mcmt1. crc4(3) is for mcme1. For mcme1, this release of hardware and software only supports fixed configuration, CRC4, hence, operation of setting will return an error. | 1.3.6.1.4.1.4253.1.9.8.1.6 | INTEGER {esf(1), d4(2), crc4(3)} | read-write | mandatory |
| mcmPortLineCoding OBJECT-TYPE Type of line coding. b8zs(1) and ami(2) are for mcmt1. hdb3(3) is for mcme1. For mcme1, this release of hardware and software only supports fixed configuration, HDB3, hence, operation of setting will return an error. | 1.3.6.1.4.1.4253.1.9.8.1.7 | INTEGER {b8zs(1), ami(2), hdb3(3)} | read-write | mandatory |
| mcmPortLineEqualizer OBJECT-TYPE The Line equilizer. ft0to133(1), ft133to266(2), ft266to399(3), ft399to533(4), and ft533to655(5) are for mcmt1. minus43dB(6) is for mcme1. For mcme1, this release of hardware and software only supports fixed configuration, -43dB, hence, operation of setting will return an error. | 1.3.6.1.4.1.4253.1.9.8.1.8 | INTEGER {ft0to133(1), ft133to266(2), ft266to399(3), ft399to533(4), ft533to655(5), minus43dB(6)} | read-write | mandatory |
| mcmPortImpedance OBJECT-TYPE Port impedance. ohms-100(1) is for mcmt1. ohms-75(2) and ohms-120(3) are for mcme1. For mcme1, this release of hardware and software only supports fixed configuration, 75 ohm, hence, operation of setting will return an error. | 1.3.6.1.4.1.4253.1.9.8.1.9 | INTEGER {ohms-100(1), ohms-75(2), ohms-120(3)} | read-only | mandatory |
| fn OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.10 | |||
| fnNumber OBJECT-TYPE Number of fn rows in the following table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.10.1 | INTEGER | not-accessible | mandatory |
| fnTable OBJECT-TYPE This table represents the information for each fn. | 1.3.6.1.4.1.4253.1.10.2 | not-accessible | mandatory | |
| fnEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.10.2.1 | not-accessible | mandatory | |
| fnID OBJECT-TYPE The slot ID the fn is in. Valid values are: 1 to 4 | 1.3.6.1.4.1.4253.1.10.2.1.1 | INTEGER (1..4) | not-accessible | mandatory |
| fnMfgDate OBJECT-TYPE Date and Time of manufacturing of the fn | 1.3.6.1.4.1.4253.1.10.2.1.2 | DateAndTime | not-accessible | mandatory |
| fnSerialNum OBJECT-TYPE Serial # of the fn. Not Supported Yet. | 1.3.6.1.4.1.4253.1.10.2.1.3 | SerialString | not-accessible | mandatory |
| fnModelType OBJECT-TYPE Model type of the fn. Up to 10 characters. Not Supported Yet. | 1.3.6.1.4.1.4253.1.10.2.1.4 | ModelString | not-accessible | mandatory |
| csim OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.11 | |||
| csimSysMode OBJECT-TYPE The ColorSim Mode of the Chassis. The value Enable means that the ColorSim feature is enabled for all the interface cards. An action element, returns other on a get request. | 1.3.6.1.4.1.4253.1.11.1 | INTEGER {enable(1), disable(2), other(3)} | read-write | mandatory |
| csimTable OBJECT-TYPE Each entry in this table represents the information for each colorsim card. | 1.3.6.1.4.1.4253.1.11.2 | not-accessible | mandatory | |
| csimEntry OBJECT-TYPE Specifies the index for each row in the table below. | 1.3.6.1.4.1.4253.1.11.2.1 | not-accessible | mandatory | |
| csimLocation OBJECT-TYPE Location of the card. Valid values are: Local in the same chassis, or remote to this chassis. | 1.3.6.1.4.1.4253.1.11.2.1.1 | CardLocation | read-only | mandatory |
| csimShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.1.11.2.1.2 | CardShelf | read-only | mandatory |
| csimSlot OBJECT-TYPE This card occupies two slots currently. | 1.3.6.1.4.1.4253.1.11.2.1.3 | SlotInput | read-only | mandatory |
| csimMode OBJECT-TYPE The Mode of ColorSIM for this entry. The Modes are Enable or Disable. | 1.3.6.1.4.1.4253.1.11.2.1.4 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| csimDCMode OBJECT-TYPE The Data Collection Mode of ColorSIM. | 1.3.6.1.4.1.4253.1.11.2.1.5 | INTEGER {standard(1), continuous(2)} | read-write | mandatory |
| csimGatingIntvl OBJECT-TYPE The Gating Interval in seconds in which the incoming data stream is being monitored for errors. | 1.3.6.1.4.1.4253.1.11.2.1.6 | INTEGER (1..65535) | read-write | mandatory |
| csimUpdtIntvl OBJECT-TYPE Number of gating intervals to be processed before the data is logged for reporting purposes. | 1.3.6.1.4.1.4253.1.11.2.1.7 | INTEGER (1..65535) | read-write | mandatory |
| csimSEIThreshold OBJECT-TYPE The SEI Threshold of ColorSIM specifies the maximum number of errored bits that may have occurred during a single gating interval before the interval is considered Severely Errorred. The Threshold values are in the form of x.ye-z. | 1.3.6.1.4.1.4253.1.11.2.1.8 | DisplayString | read-write | mandatory |
| rpsm OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.12 | |||
| rpsmBootPromVer OBJECT-TYPE The current version string of the rpsm Boot PROM code | 1.3.6.1.4.1.4253.1.12.1 | VersionString | not-accessible | mandatory |
| rpsmROMSize OBJECT-TYPE Total Size of the ROM in Kilobyes | 1.3.6.1.4.1.4253.1.12.2 | INTEGER (0..1024) | not-accessible | mandatory |
| rpsmNumSubDiv OBJECT-TYPE Number of the subdivisions of the ROM. | 1.3.6.1.4.1.4253.1.12.3 | INTEGER (0..20) | not-accessible | mandatory |
| rpsmSubDivTable OBJECT-TYPE This table represents the number of sub divisions and the size of each subdivision in ROM memory | 1.3.6.1.4.1.4253.1.12.4 | not-accessible | mandatory | |
| rpsmSubDivEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.12.4.1 | not-accessible | mandatory | |
| rpsmSubDivIndex OBJECT-TYPE Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM. | 1.3.6.1.4.1.4253.1.12.4.1.1 | INTEGER (0..20) | not-accessible | mandatory |
| rpsmSubDivDescr OBJECT-TYPE Display Name of each Sub Division in ROM | 1.3.6.1.4.1.4253.1.12.4.1.2 | DisplayString (SIZE(0..20)) | not-accessible | mandatory |
| rpsmSubDivSize OBJECT-TYPE Size of each sub division in ROM in kilobytes | 1.3.6.1.4.1.4253.1.12.4.1.3 | INTEGER (0..1024) | not-accessible | mandatory |
| rpsmSubDivOffset OBJECT-TYPE Starting address of each sub division in the ROM in HEX notation. | 1.3.6.1.4.1.4253.1.12.4.1.4 | OCTET STRING (SIZE(0..8)) | not-accessible | mandatory |
| rpsmNumber OBJECT-TYPE Number of RPSM rows in the following table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.12.5 | INTEGER | not-accessible | mandatory |
| rpsmTable OBJECT-TYPE This table represents the information for each RPSM card | 1.3.6.1.4.1.4253.1.12.6 | not-accessible | mandatory | |
| rpsmEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.12.6.1 | not-accessible | mandatory | |
| rpsmCardLocation OBJECT-TYPE Location of the RPSM card. Valid values are: Local in the same chassis, or remote to this chassis. | 1.3.6.1.4.1.4253.1.12.6.1.1 | CardLocation | not-accessible | mandatory |
| rpsmCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.12.6.1.2 | CardShelf | not-accessible | mandatory |
| rpsmCardSlot OBJECT-TYPE The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.12.6.1.3 | SlotInput | not-accessible | mandatory |
| rpsmModelNum OBJECT-TYPE RPSM's model number. | 1.3.6.1.4.1.4253.1.12.6.1.4 | DisplayString | not-accessible | mandatory |
| rpsmOpticsMfgDate OBJECT-TYPE Date and Time of manufacturing of the optics on the RPSM card. | 1.3.6.1.4.1.4253.1.12.6.1.5 | DateAndTime | not-accessible | mandatory |
| rpsmSerialNum OBJECT-TYPE Serial # of the RPSM card. | 1.3.6.1.4.1.4253.1.12.6.1.6 | SerialString | not-accessible | mandatory |
| rpsmModelType OBJECT-TYPE Model type of the RPSM. | 1.3.6.1.4.1.4253.1.12.6.1.7 | INTEGER {rpsm(17)} | not-accessible | mandatory |
| rpsmHWName OBJECT-TYPE Manufacturing Hardware name of the RPSM Card. | 1.3.6.1.4.1.4253.1.12.6.1.8 | CardName | not-accessible | mandatory |
| rpsmFWVersionID OBJECT-TYPE The current version string of the RPSM FW code | 1.3.6.1.4.1.4253.1.12.6.1.9 | VersionString | not-accessible | mandatory |
| rpsmCardName OBJECT-TYPE User configurable card name. | 1.3.6.1.4.1.4253.1.12.6.1.10 | CardName | not-accessible | mandatory |
| rpsmFWName OBJECT-TYPE RPSM's Firmware Name. | 1.3.6.1.4.1.4253.1.12.6.1.11 | DisplayString | not-accessible | mandatory |
| rpsmFWDate OBJECT-TYPE Date and Time of latest Firmware of the RPSM card. | 1.3.6.1.4.1.4253.1.12.6.1.12 | DateAndTime | not-accessible | mandatory |
| rpsmHWVersionID OBJECT-TYPE The current version string of the RPSM HW code. | 1.3.6.1.4.1.4253.1.12.6.1.13 | VersionString | not-accessible | mandatory |
| rpsmHWDate OBJECT-TYPE Date and Time of Hardware of the RPSM card. | 1.3.6.1.4.1.4253.1.12.6.1.14 | DateAndTime | not-accessible | mandatory |
| rpsmSetState OBJECT-TYPE Instruct the rpsm to do a warmboot. A get on this will always return an other. | 1.3.6.1.4.1.4253.1.12.6.1.15 | RebootType | not-accessible | mandatory |
| rpsmExpressLoss OBJECT-TYPE Insertion loss for the expressed channel through the RPSM module in dB. | 1.3.6.1.4.1.4253.1.12.6.1.16 | DisplayString | not-accessible | mandatory |
| rpsmMarginForSwitch OBJECT-TYPE Switching threshold in dB for protection switch to occur. | 1.3.6.1.4.1.4253.1.12.6.1.17 | INTEGER (-40..0) | not-accessible | mandatory |
| rpsmMinProtPowerForSwitch OBJECT-TYPE Minimum protection link's light power in dBm to allow protection switching to occur. | 1.3.6.1.4.1.4253.1.12.6.1.18 | INTEGER (-40..0) | not-accessible | mandatory |
| rpsmDeBounce OBJECT-TYPE Debounce in number of times to measure low light power before protection switch. | 1.3.6.1.4.1.4253.1.12.6.1.19 | INTEGER | not-accessible | mandatory |
| rpsmBlackOutTime OBJECT-TYPE Black out time in unit of 0.1 second after protection switch to allow another protection switch to occur again. | 1.3.6.1.4.1.4253.1.12.6.1.20 | INTEGER | not-accessible | mandatory |
| rpsmSwitch OBJECT-TYPE instruct the RPSM to take on an action, such as: switch to link A or link B. A get would alway return other(1). | 1.3.6.1.4.1.4253.1.12.6.1.21 | INTEGER {other(1), switchToLinkA(2), switchToLinkB(3), toggle(4), enableAutoSwitch(6)} | not-accessible | mandatory |
| rpsmAddDropLoss OBJECT-TYPE Insertion loss of the Add/Drop path through the RPSM module in dB. | 1.3.6.1.4.1.4253.1.12.6.1.22 | DisplayString | not-accessible | mandatory |
| rpsmPathID OBJECT-TYPE Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path. | 1.3.6.1.4.1.4253.1.12.6.1.23 | PathIdName | not-accessible | mandatory |
| rpsmAdminState OBJECT-TYPE Administrative control over that rpsm card. Default value is enable. When disabled, no alarms/events gets generated. | 1.3.6.1.4.1.4253.1.12.6.1.24 | INTEGER {disable(1), enable(2), na(3)} | not-accessible | mandatory |
| rpsmPortTable OBJECT-TYPE This table represents the physical connection for each RPSM card's port. | 1.3.6.1.4.1.4253.1.12.7 | not-accessible | mandatory | |
| rpsmPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.12.7.1 | not-accessible | mandatory | |
| rpsmPortCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.12.7.1.1 | CardShelf | not-accessible | mandatory |
| rpsmPortCardSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.1.12.7.1.2 | SlotInput | not-accessible | mandatory |
| rpsmPortType OBJECT-TYPE Type of the RPSM's port. The order is CLI compatible. | 1.3.6.1.4.1.4253.1.12.7.1.3 | INTEGER {linkEast(1), linkWest(2), in(3), out(4), aTOd(5), exp(6)} | not-accessible | mandatory |
| rpsmConnCardType OBJECT-TYPE Type of connection. Valid values are ocmu(2), ocmItu(3), mux(4), demux(5), mcm(8), w4cd(10), w2cmd(13), w4cm(21), osam(20), fadm(6), oppm(7), fadmb(19), ocme(24), etc... A zero will be used for no connections. | 1.3.6.1.4.1.4253.1.12.7.1.4 | INTEGER (0..30) | not-accessible | mandatory |
| rpsmConnPort OBJECT-TYPE Conn port for RPSM's port.Possible values based on card types that can connect to RPSM are: OFCM/OFCD: 1/2/3/4= port index, 5=EXP, 6=OUT/IN W4CM/W4CD: 1=1510, 2=1530, 3=1550, 4=1570, 5=EXP, 6=IN/OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT OSAM: 1=IN, 2=OUT FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx FADMB: 1=A/D, 2=EXP, 3=Local, 4=Rx OCMU/OCMITU/MCM: 1=Link Tx, 2=Link Rx UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx | 1.3.6.1.4.1.4253.1.12.7.1.5 | INTEGER | not-accessible | mandatory |
| rpsmConnShelf OBJECT-TYPE The shelf the card conn to. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.12.7.1.6 | ShelfInput | not-accessible | mandatory |
| rpsmConnSlot OBJECT-TYPE The slot within the shelf the card conn to. | 1.3.6.1.4.1.4253.1.12.7.1.7 | SlotInput | not-accessible | mandatory |
| rsdm OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.13 | |||
| rsdmBootPromVer OBJECT-TYPE The current version string of the rsdm Boot PROM code | 1.3.6.1.4.1.4253.1.13.1 | VersionString | not-accessible | mandatory |
| rsdmROMSize OBJECT-TYPE Total Size of the ROM in Kilobyes | 1.3.6.1.4.1.4253.1.13.2 | INTEGER (0..1024) | not-accessible | mandatory |
| rsdmNumSubDiv OBJECT-TYPE Number of the subdivisions of the ROM. | 1.3.6.1.4.1.4253.1.13.3 | INTEGER (0..20) | not-accessible | mandatory |
| rsdmSubDivTable OBJECT-TYPE This table represents the number of sub divisions and the size of each subdivision in ROM memory | 1.3.6.1.4.1.4253.1.13.4 | not-accessible | mandatory | |
| rsdmSubDivEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.13.4.1 | not-accessible | mandatory | |
| rsdmSubDivIndex OBJECT-TYPE Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM. | 1.3.6.1.4.1.4253.1.13.4.1.1 | INTEGER (0..20) | not-accessible | mandatory |
| rsdmSubDivDescr OBJECT-TYPE Display Name of each Sub Division in ROM | 1.3.6.1.4.1.4253.1.13.4.1.2 | DisplayString (SIZE(0..20)) | not-accessible | mandatory |
| rsdmSubDivSize OBJECT-TYPE Size of each sub division in ROM in kilobytes | 1.3.6.1.4.1.4253.1.13.4.1.3 | INTEGER (0..1024) | not-accessible | mandatory |
| rsdmSubDivOffset OBJECT-TYPE Starting address of each sub division in the ROM in HEX notation. | 1.3.6.1.4.1.4253.1.13.4.1.4 | OCTET STRING (SIZE(0..8)) | not-accessible | mandatory |
| rsdmNumber OBJECT-TYPE Number of RSDM rows in the following table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.13.5 | INTEGER | not-accessible | mandatory |
| rsdmTable OBJECT-TYPE This table represents the information for each RSDM card | 1.3.6.1.4.1.4253.1.13.6 | not-accessible | mandatory | |
| rsdmEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.13.6.1 | not-accessible | mandatory | |
| rsdmCardLocation OBJECT-TYPE Location of the RSDM card. Valid values are: Local in the same chassis, or remote to this chassis. | 1.3.6.1.4.1.4253.1.13.6.1.1 | CardLocation | not-accessible | mandatory |
| rsdmCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2 | 1.3.6.1.4.1.4253.1.13.6.1.2 | CardShelf | not-accessible | mandatory |
| rsdmCardSlot OBJECT-TYPE The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.13.6.1.3 | SlotInput | not-accessible | mandatory |
| rsdmModelNum OBJECT-TYPE RSDM's model number. | 1.3.6.1.4.1.4253.1.13.6.1.4 | DisplayString | not-accessible | mandatory |
| rsdmOpticsMfgDate OBJECT-TYPE Date and Time of manufacturing of the optics on the RSDM card. | 1.3.6.1.4.1.4253.1.13.6.1.5 | DateAndTime | not-accessible | mandatory |
| rsdmSerialNum OBJECT-TYPE Serial # of the RSDM card. | 1.3.6.1.4.1.4253.1.13.6.1.6 | SerialString | not-accessible | mandatory |
| rsdmModelType OBJECT-TYPE Model type of the RSDM. | 1.3.6.1.4.1.4253.1.13.6.1.7 | INTEGER {rsdm(16)} | not-accessible | mandatory |
| rsdmHWName OBJECT-TYPE Display Hardware name of the RSDM Card. | 1.3.6.1.4.1.4253.1.13.6.1.8 | CardName | not-accessible | mandatory |
| rsdmCardName OBJECT-TYPE User configurable name of the RSDM Card. | 1.3.6.1.4.1.4253.1.13.6.1.9 | CardName | not-accessible | mandatory |
| rsdmFWVersionID OBJECT-TYPE The current version string of the RSDM FW code | 1.3.6.1.4.1.4253.1.13.6.1.10 | VersionString | not-accessible | mandatory |
| rsdmFWName OBJECT-TYPE RSDM's Firmware Name. | 1.3.6.1.4.1.4253.1.13.6.1.11 | DisplayString | not-accessible | mandatory |
| rsdmFWDate OBJECT-TYPE Date and Time of latest Firmware of the RSDM card. | 1.3.6.1.4.1.4253.1.13.6.1.12 | DateAndTime | not-accessible | mandatory |
| rsdmHWVersionID OBJECT-TYPE The current version string of the RSDM HW code. | 1.3.6.1.4.1.4253.1.13.6.1.13 | VersionString | not-accessible | mandatory |
| rsdmHWDate OBJECT-TYPE Date and Time of Hardware of the RSDM card. | 1.3.6.1.4.1.4253.1.13.6.1.14 | DateAndTime | not-accessible | mandatory |
| rsdmSetState OBJECT-TYPE Instruct the rsdm to do a warmboot. A get on this will always return an other. | 1.3.6.1.4.1.4253.1.13.6.1.15 | RebootType | not-accessible | mandatory |
| rsdmRxITUNumber OBJECT-TYPE Receive port's ITU wavelength number. | 1.3.6.1.4.1.4253.1.13.6.1.16 | INTEGER | not-accessible | mandatory |
| rsdmTxITUNumber OBJECT-TYPE Transmit port's ITU wavelength number. | 1.3.6.1.4.1.4253.1.13.6.1.17 | INTEGER | not-accessible | mandatory |
| rsdmRxInsertionLoss OBJECT-TYPE Receive port's insertion loss in dB. | 1.3.6.1.4.1.4253.1.13.6.1.18 | DisplayString | not-accessible | mandatory |
| rsdmTxInsertionLoss OBJECT-TYPE Transmit port's insertion loss in dB. | 1.3.6.1.4.1.4253.1.13.6.1.19 | DisplayString | not-accessible | mandatory |
| rsdmExpressLoss OBJECT-TYPE Insertion loss for the expressed channel through the RSDM module in dB. | 1.3.6.1.4.1.4253.1.13.6.1.20 | DisplayString | not-accessible | mandatory |
| rsdmMarginForSwitch OBJECT-TYPE Switching threshold in dB for protection switch to occur. | 1.3.6.1.4.1.4253.1.13.6.1.21 | INTEGER (-40..0) | not-accessible | mandatory |
| rsdmMinProtPowerForSwitch OBJECT-TYPE Minimum protection link's light power in dBm to allow protection switching to occur. | 1.3.6.1.4.1.4253.1.13.6.1.22 | INTEGER (-40..0) | not-accessible | mandatory |
| rsdmDeBounce OBJECT-TYPE Debounce in number of times to measure low light power before protection switch. | 1.3.6.1.4.1.4253.1.13.6.1.23 | INTEGER | not-accessible | mandatory |
| rsdmBlackOutTime OBJECT-TYPE Black out time in unit of 0.1 second after protection switch to allow another protection switch to occur again. | 1.3.6.1.4.1.4253.1.13.6.1.24 | INTEGER | not-accessible | mandatory |
| rsdmSwitch OBJECT-TYPE Instruct the RSDM to take on an action, such as: switch to link A or link B. A snmp get would always return other(1). | 1.3.6.1.4.1.4253.1.13.6.1.25 | INTEGER {other(1), switchToLinkA(2), switchToLinkB(3), toggle(4), enableAutoSwitch(6)} | not-accessible | mandatory |
| rsdmPathID OBJECT-TYPE Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path. | 1.3.6.1.4.1.4253.1.13.6.1.26 | PathIdName | not-accessible | mandatory |
| rsdmAdminState OBJECT-TYPE Administrative control over that rsdm card. Default value is enable. When disabled, no alarms/events gets generated. | 1.3.6.1.4.1.4253.1.13.6.1.27 | INTEGER {disable(1), enable(2), na(3)} | not-accessible | mandatory |
| rsdmPortTable OBJECT-TYPE This table represents the physical connection for each RSDM card's port. | 1.3.6.1.4.1.4253.1.13.7 | not-accessible | mandatory | |
| rsdmPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.13.7.1 | not-accessible | mandatory | |
| rsdmPortCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.13.7.1.1 | CardShelf | not-accessible | mandatory |
| rsdmPortCardSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.1.13.7.1.2 | SlotInput | not-accessible | mandatory |
| rsdmPortType OBJECT-TYPE Type of the RSDM's port. The order is CLI compatible. | 1.3.6.1.4.1.4253.1.13.7.1.3 | INTEGER {linkEast(1), linkWest(2), linkRx(3), linkTx(4)} | not-accessible | mandatory |
| rsdmConnCardType OBJECT-TYPE Type of connection. Valid values are ocmu(2), ocmItu(3), mux(4), demux(5), mcm(8), w4cd(10), w2cmd(13), w4cm(21), osam(20), fadm(6), oppm(7), fadmb(19), ocme(24), etc... A zero will be used for no connections. | 1.3.6.1.4.1.4253.1.13.7.1.4 | CardType | not-accessible | mandatory |
| rsdmConnPort OBJECT-TYPE Conn port for RSDM's port.Possible values based on card types that can connect to RSDM are: OFCM/OFCD: 1/2/3/4= port index, 5=EXP, 6=OUT/IN W4CM/W4CD: 1=1510, 2=1530, 3=1550, 4=1570, 5=EXP, 6=IN/OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT OSAM: 1=IN, 2=OUT FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx FADMB: 1=A/D, 2=EXP, 3=Local, 4=Rx OCMU/OCMITU/MCM: 1=Link Tx, 2=Link Rx UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx | 1.3.6.1.4.1.4253.1.13.7.1.5 | INTEGER | not-accessible | mandatory |
| rsdmConnShelf OBJECT-TYPE The shelf the card conn to. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.13.7.1.6 | ShelfInput | not-accessible | mandatory |
| rsdmConnSlot OBJECT-TYPE The slot within the shelf the card conn to. | 1.3.6.1.4.1.4253.1.13.7.1.7 | SlotInput | not-accessible | mandatory |
| rtdm OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.14 | |||
| rtdmBootPromVer OBJECT-TYPE The current version string of the RTDM Boot PROM code | 1.3.6.1.4.1.4253.1.14.1 | VersionString | not-accessible | mandatory |
| rtdmROMSize OBJECT-TYPE Total Size of the ROM in Kilobyes | 1.3.6.1.4.1.4253.1.14.2 | INTEGER (0..1024) | not-accessible | mandatory |
| rtdmNumSubDiv OBJECT-TYPE Number of the subdivisions of the ROM. | 1.3.6.1.4.1.4253.1.14.3 | INTEGER (0..20) | not-accessible | mandatory |
| rtdmSubDivTable OBJECT-TYPE This table represents the number of sub divisions and the size of each subdivision in ROM memory | 1.3.6.1.4.1.4253.1.14.4 | not-accessible | mandatory | |
| rtdmSubDivEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.14.4.1 | not-accessible | mandatory | |
| rtdmSubDivIndex OBJECT-TYPE Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM. | 1.3.6.1.4.1.4253.1.14.4.1.1 | INTEGER (0..20) | not-accessible | mandatory |
| rtdmSubDivDescr OBJECT-TYPE Display Name of each Sub Division in ROM | 1.3.6.1.4.1.4253.1.14.4.1.2 | DisplayString (SIZE(0..20)) | not-accessible | mandatory |
| rtdmSubDivSize OBJECT-TYPE Size of each sub division in ROM in kilobytes | 1.3.6.1.4.1.4253.1.14.4.1.3 | INTEGER (0..1024) | not-accessible | mandatory |
| rtdmSubDivOffset OBJECT-TYPE Starting address of each sub division in the ROM in HEX notation. | 1.3.6.1.4.1.4253.1.14.4.1.4 | OCTET STRING (SIZE(0..8)) | not-accessible | mandatory |
| rtdmNumber OBJECT-TYPE Number of RTDM rows in the following table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.14.5 | INTEGER | not-accessible | mandatory |
| rtdmTable OBJECT-TYPE This table represents the information for each RTDM card | 1.3.6.1.4.1.4253.1.14.6 | not-accessible | mandatory | |
| rtdmEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.14.6.1 | not-accessible | mandatory | |
| rtdmCardLocation OBJECT-TYPE Location of the RTDM card. Valid values are: Local in the same chassis, or remote to this chassis | 1.3.6.1.4.1.4253.1.14.6.1.1 | CardLocation | not-accessible | mandatory |
| rtdmCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.1.14.6.1.2 | CardShelf | not-accessible | mandatory |
| rtdmCardSlot OBJECT-TYPE The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.14.6.1.3 | SlotInput | not-accessible | mandatory |
| rtdmModelNum OBJECT-TYPE Model number for RTDM. | 1.3.6.1.4.1.4253.1.14.6.1.4 | DisplayString | not-accessible | mandatory |
| rtdmOpticsMfgDate OBJECT-TYPE Date and Time of manufacturing of the optics on the RTDM card | 1.3.6.1.4.1.4253.1.14.6.1.5 | DateAndTime | not-accessible | mandatory |
| rtdmSerialNum OBJECT-TYPE Serial # of the RTDM card. | 1.3.6.1.4.1.4253.1.14.6.1.6 | SerialString | not-accessible | mandatory |
| rtdmModelType OBJECT-TYPE Model type of the RTDM | 1.3.6.1.4.1.4253.1.14.6.1.7 | INTEGER {rtdm(18)} | not-accessible | mandatory |
| rtdmHWName OBJECT-TYPE Display (Network) name of the RTDM Card | 1.3.6.1.4.1.4253.1.14.6.1.8 | CardName | not-accessible | mandatory |
| rtdmFWVersionID OBJECT-TYPE The current version string of the RTDM FW code | 1.3.6.1.4.1.4253.1.14.6.1.9 | VersionString | not-accessible | mandatory |
| rtdmCardName OBJECT-TYPE User configurable card name. | 1.3.6.1.4.1.4253.1.14.6.1.10 | CardName | not-accessible | mandatory |
| rtdmFWName OBJECT-TYPE RTDM's Firmware Name. | 1.3.6.1.4.1.4253.1.14.6.1.11 | DisplayString | not-accessible | mandatory |
| rtdmFWDate OBJECT-TYPE Date and Time of latest Firmware of the RTDM card | 1.3.6.1.4.1.4253.1.14.6.1.12 | DateAndTime | not-accessible | mandatory |
| rtdmHWVersionID OBJECT-TYPE The current version string of the RTDM HW code | 1.3.6.1.4.1.4253.1.14.6.1.13 | VersionString | not-accessible | mandatory |
| rtdmHWDate OBJECT-TYPE Date and Time of Hardware of the RTDM card | 1.3.6.1.4.1.4253.1.14.6.1.14 | DateAndTime | not-accessible | mandatory |
| rtdmSetState OBJECT-TYPE Instruct the rtdm to do a warmboot. A get on this will always return an other. | 1.3.6.1.4.1.4253.1.14.6.1.15 | RebootType | not-accessible | mandatory |
| rtdmCommonEInsertionLoss OBJECT-TYPE The RTDM Common path East's insertion loss in dB. | 1.3.6.1.4.1.4253.1.14.6.1.16 | DisplayString | not-accessible | mandatory |
| rtdmCommonWInsertionLoss OBJECT-TYPE The RTDM Common path West's insertion loss in dB. | 1.3.6.1.4.1.4253.1.14.6.1.17 | DisplayString | not-accessible | mandatory |
| rtdmMonEastInsertionLoss OBJECT-TYPE The RTDM Monitor East Path's insertion loss in dB. | 1.3.6.1.4.1.4253.1.14.6.1.18 | DisplayString | not-accessible | mandatory |
| rtdmMonWestInsertionLoss OBJECT-TYPE The RTDM Monitor West Path's insertion loss in dB. | 1.3.6.1.4.1.4253.1.14.6.1.19 | DisplayString | not-accessible | mandatory |
| rtdmPathID OBJECT-TYPE Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path. | 1.3.6.1.4.1.4253.1.14.6.1.20 | PathIdName | not-accessible | mandatory |
| rtdmAdminState OBJECT-TYPE Administrative control over that rtdm card. Default value is enable. When disabled, no alarms/events gets generated. | 1.3.6.1.4.1.4253.1.14.6.1.21 | INTEGER {disable(1), enable(2), na(3)} | not-accessible | mandatory |
| rtdmPortTable OBJECT-TYPE This table represents the physical connection for each RTDM card's port. | 1.3.6.1.4.1.4253.1.14.7 | not-accessible | mandatory | |
| rtdmPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.14.7.1 | not-accessible | mandatory | |
| rtdmPortCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.14.7.1.1 | CardShelf | not-accessible | mandatory |
| rtdmPortCardSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.1.14.7.1.2 | SlotInput | not-accessible | mandatory |
| rtdmPortType OBJECT-TYPE Type of the RTDM's port. The order is CLI compatible. | 1.3.6.1.4.1.4253.1.14.7.1.3 | INTEGER {localRx(1)} | not-accessible | mandatory |
| rtdmConnCardType OBJECT-TYPE Type of connection. Valid values are ocmu(2), ocmItu(3), mux(4), demux(5), mcm(8), w4cd(10), w2cmd(13), w4cm(21), osam(20), fadm(6), oppm(7), fadmb(19), ocme(24), etc... | 1.3.6.1.4.1.4253.1.14.7.1.4 | INTEGER (0..30) | not-accessible | mandatory |
| rtdmConnPort OBJECT-TYPE Conn port for RTDM's port.Possible values based on card types that can connect to RTDM are: OFCM/OFCD: 1/2/3/4= port index, 5=EXP, 6=OUT/IN W4CM/W4CD: 1=1510, 2=1530, 3=1550, 4=1570, 5=EXP, 6=IN/OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT OSAM: 1=IN, 2=OUT FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx FADMB: 1=A/D, 2=EXP, 3=Local, 4=Rx OCMU/OCMITU/MCM: 1=Link Tx, 2=Link Rx UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx | 1.3.6.1.4.1.4253.1.14.7.1.5 | INTEGER | not-accessible | mandatory |
| rtdmConnShelf OBJECT-TYPE The shelf the card conn to. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.14.7.1.6 | ShelfInput | not-accessible | mandatory |
| rtdmConnSlot OBJECT-TYPE The slot within the shelf the card conn to. A zero will be used for no connections. | 1.3.6.1.4.1.4253.1.14.7.1.7 | SlotInput | not-accessible | mandatory |
| osam OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.15 | |||
| osamBootPromVer OBJECT-TYPE The current version string of the osam boot prom code. | 1.3.6.1.4.1.4253.1.15.1 | VersionString | not-accessible | mandatory |
| osamROMSize OBJECT-TYPE Total Size of the ROM in Kilobytes. | 1.3.6.1.4.1.4253.1.15.2 | INTEGER (0..1024) | not-accessible | mandatory |
| osamNumSubDiv OBJECT-TYPE Number of the ROM's subdivisions. | 1.3.6.1.4.1.4253.1.15.3 | INTEGER (0..20) | not-accessible | mandatory |
| osamSubDivTable OBJECT-TYPE This table represents the number of sub divisions and the size of each subdivision in ROM memory | 1.3.6.1.4.1.4253.1.15.4 | not-accessible | mandatory | |
| osamSubDivEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.15.4.1 | not-accessible | mandatory | |
| osamSubDivIndex OBJECT-TYPE Integer ID of each subdivision. | 1.3.6.1.4.1.4253.1.15.4.1.1 | INTEGER (0..20) | not-accessible | mandatory |
| osamSubDivDescr OBJECT-TYPE Display name of each subdivision. | 1.3.6.1.4.1.4253.1.15.4.1.2 | DisplayString (SIZE(0..20)) | not-accessible | mandatory |
| osamSubDivSize OBJECT-TYPE Size of each subdivision in Kbytes. | 1.3.6.1.4.1.4253.1.15.4.1.3 | INTEGER (0..1024) | not-accessible | mandatory |
| osamSubDivOffset OBJECT-TYPE Starting address of each sub division in HEX format. | 1.3.6.1.4.1.4253.1.15.4.1.4 | OCTET STRING (SIZE(0..8)) | not-accessible | mandatory |
| osamNumber OBJECT-TYPE Number of rows in the osam table. | 1.3.6.1.4.1.4253.1.15.5 | INTEGER (0..32) | read-only | mandatory |
| osamTable OBJECT-TYPE This table represents the information for each osam card | 1.3.6.1.4.1.4253.1.15.6 | not-accessible | mandatory | |
| osamEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.15.6.1 | not-accessible | mandatory | |
| osamCardLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.15.6.1.1 | CardLocation | read-only | mandatory |
| osamCardShelf OBJECT-TYPE The shelf number in which the module is plugged in. | 1.3.6.1.4.1.4253.1.15.6.1.2 | CardShelf | read-only | mandatory |
| osamCardSlot OBJECT-TYPE The slot number in which the module is plugged in. If a 0 is written into this mib element, the module will be deleted from the system. | 1.3.6.1.4.1.4253.1.15.6.1.3 | INTEGER (0..16) | read-write | mandatory |
| osamModelNum OBJECT-TYPE Manufacturing model number of the module. | 1.3.6.1.4.1.4253.1.15.6.1.4 | ModelNum | read-only | mandatory |
| osamSerialNum OBJECT-TYPE Unique serial number of the module. | 1.3.6.1.4.1.4253.1.15.6.1.5 | SerialString | read-only | mandatory |
| osamModelType OBJECT-TYPE Model type of the module. | 1.3.6.1.4.1.4253.1.15.6.1.6 | CardType | read-only | mandatory |
| osamHWName OBJECT-TYPE Manufacturing Hardware name of the module. | 1.3.6.1.4.1.4253.1.15.6.1.7 | CardName | read-only | mandatory |
| osamHWVersionID OBJECT-TYPE The current hardware version string of the module. | 1.3.6.1.4.1.4253.1.15.6.1.8 | VersionString | read-only | mandatory |
| osamHWDate OBJECT-TYPE Date of manufacturing of the electronics portion of the module. | 1.3.6.1.4.1.4253.1.15.6.1.9 | DateAndTime | read-only | mandatory |
| osamFWName OBJECT-TYPE Manufacturing Firmware name of the module. | 1.3.6.1.4.1.4253.1.15.6.1.10 | CardName | read-only | mandatory |
| osamFWVersionID OBJECT-TYPE The current firmware version string of the module. | 1.3.6.1.4.1.4253.1.15.6.1.11 | VersionString | read-only | mandatory |
| osamFWDate OBJECT-TYPE Release date for the firmware of the module. | 1.3.6.1.4.1.4253.1.15.6.1.12 | DateAndTime | read-only | mandatory |
| osamCardName OBJECT-TYPE User configurable card name for the module. | 1.3.6.1.4.1.4253.1.15.6.1.13 | CardName | read-write | mandatory |
| osamSetState OBJECT-TYPE Instruct the osam module to do a reset. A get on this will always return other. | 1.3.6.1.4.1.4253.1.15.6.1.14 | RebootType | read-write | mandatory |
| osamLaserState OBJECT-TYPE The operational state of the laser. | 1.3.6.1.4.1.4253.1.15.6.1.15 | FlagType | read-only | mandatory |
| osamOperationMode OBJECT-TYPE Operation mode of the module. powerControlled(3) is not supported by OSAM modules. currentControlled(1) is not supported OSAM-HP/LP modules. | 1.3.6.1.4.1.4253.1.15.6.1.16 | INTEGER {currentControlled(1), gainControlled(2), powerControlled(3)} | read-write | mandatory |
| osamLaserBiasCurrent OBJECT-TYPE Constant current in mA to be used by the module when the operation mode is set to currentControlled. This value can't be set if operation mode is set to gainControlled. Applicable only to OSAM module | 1.3.6.1.4.1.4253.1.15.6.1.17 | INTEGER (40..200) | read-write | mandatory |
| osamAmplifierGain OBJECT-TYPE Constant gain in dB to be used by the module when the operation mode is set to gainControlled. This value can't be set if operation mode is set to currentControlled. Not applicable to OSAM-HP/LP module | 1.3.6.1.4.1.4253.1.15.6.1.18 | INTEGER (0..30) | read-write | mandatory |
| osamConfigCommit OBJECT-TYPE This allows the current module configuration to be stored in permanent storage. | 1.3.6.1.4.1.4253.1.15.6.1.19 | INTEGER {other(1), save(2)} | read-write | mandatory |
| osamNoiseFigure OBJECT-TYPE The calibrated noise figure of the gain block in dB. Applicable only to OSAM module | 1.3.6.1.4.1.4253.1.15.6.1.20 | INTEGER (0..10) | read-only | mandatory |
| osamPathID OBJECT-TYPE Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path. | 1.3.6.1.4.1.4253.1.15.6.1.21 | PathIdName | read-write | mandatory |
| osamAdminState OBJECT-TYPE Administrative control over that osam card. Default value is enable. When disabled, no alarms/events gets generated. | 1.3.6.1.4.1.4253.1.15.6.1.22 | INTEGER {disable(1), enable(2), na(3)} | read-write | mandatory |
| osam2NoiseFigure OBJECT-TYPE The calibrated noise figure of the gain block in dBm. Applicable only to OSAM-HP/LP module | 1.3.6.1.4.1.4253.1.15.6.1.23 | DisplayString | read-only | mandatory |
| osam2GainReq OBJECT-TYPE Constant gain in dB to be used by the module when the operation mode is set to gainControlled. This value can't be set if operation mode is set to powerControlled. Range is 0-16.5db(LP) and 0-23.3db(HP) Applicable only to OSAM-HP/LP module | 1.3.6.1.4.1.4253.1.15.6.1.24 | DisplayString | read-write | mandatory |
| osam2OpPowerReq OBJECT-TYPE Constant output power in dBm to be used by the module when the operation mode is set to powerControlled. This value can't be set if operation mode is set to gainControlled. Range is 0-9dbm (LP) and 0-18dbm(HP) Applicable only to OSAM-HP/LP module | 1.3.6.1.4.1.4253.1.15.6.1.25 | DisplayString | read-write | mandatory |
| osamCleiNum OBJECT-TYPE CLEI number of the osam Card. | 1.3.6.1.4.1.4253.1.15.6.1.26 | DisplayString | read-only | mandatory |
| osamNumPorts OBJECT-TYPE Total port numbers on each OSAM card. | 1.3.6.1.4.1.4253.1.15.6.1.27 | INTEGER | read-only | mandatory |
| osamPortTable OBJECT-TYPE This table represents the physical connection for each OSAM card's port. | 1.3.6.1.4.1.4253.1.15.7 | not-accessible | mandatory | |
| osamPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.15.7.1 | not-accessible | mandatory | |
| osamPortCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.15.7.1.1 | CardShelf | read-only | mandatory |
| osamPortCardSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.1.15.7.1.2 | SlotInput | read-only | mandatory |
| osamPortType OBJECT-TYPE Type of the OSAM's port. | 1.3.6.1.4.1.4253.1.15.7.1.3 | INTEGER {in(1), out(2)} | read-write | mandatory |
| osamConnCardType OBJECT-TYPE Module type connectioned to osam port. | 1.3.6.1.4.1.4253.1.15.7.1.4 | CardType | read-write | mandatory |
| osamConnPort OBJECT-TYPE Conn port for OSAM's port. Possible values based on card types that can be connected to OSAM are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. | 1.3.6.1.4.1.4253.1.15.7.1.5 | INTEGER | read-write | mandatory |
| osamConnShelf OBJECT-TYPE The shelf the card conn to. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.15.7.1.6 | ShelfInput | read-write | mandatory |
| osamConnSlot OBJECT-TYPE The slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0. | 1.3.6.1.4.1.4253.1.15.7.1.7 | SlotInput | read-write | mandatory |
| osamPortCardType OBJECT-TYPE Type of OSAM module. | 1.3.6.1.4.1.4253.1.15.7.1.8 | CardType | read-only | mandatory |
| osamConnLocation OBJECT-TYPE The chassis's location of the card connected to. | 1.3.6.1.4.1.4253.1.15.7.1.9 | CardLocation | read-only | mandatory |
| osamConnChassisID OBJECT-TYPE Chassis ID of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the chassis Id of the local node. | 1.3.6.1.4.1.4253.1.15.7.1.10 | DisplayString | read-only | mandatory |
| osamConnSystemName OBJECT-TYPE System Name of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the sysetem name of the local node. | 1.3.6.1.4.1.4253.1.15.7.1.11 | DisplayString | read-only | mandatory |
| osamConnIpAddress OBJECT-TYPE IpAddress of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the IP address of the node. | 1.3.6.1.4.1.4253.1.15.7.1.12 | IpAddress | read-only | mandatory |
| rsm OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.16 | |||
| rsmBootPromVer OBJECT-TYPE The current version string of the rsm Boot PROM code | 1.3.6.1.4.1.4253.1.16.1 | VersionString | not-accessible | mandatory |
| rsmROMSize OBJECT-TYPE Total Size of the ROM in Kilobyes | 1.3.6.1.4.1.4253.1.16.2 | INTEGER (0..1024) | not-accessible | mandatory |
| rsmNumSubDiv OBJECT-TYPE Number of the subdivisions of the ROM. | 1.3.6.1.4.1.4253.1.16.3 | INTEGER (0..20) | not-accessible | mandatory |
| rsmSubDivTable OBJECT-TYPE This table represents the number of sub divisions and the size of each subdivision in ROM memory | 1.3.6.1.4.1.4253.1.16.4 | not-accessible | mandatory | |
| rsmSubDivEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.16.4.1 | not-accessible | mandatory | |
| rsmSubDivIndex OBJECT-TYPE Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM. | 1.3.6.1.4.1.4253.1.16.4.1.1 | INTEGER (0..20) | not-accessible | mandatory |
| rsmSubDivDescr OBJECT-TYPE Display Name of each Sub Division in ROM | 1.3.6.1.4.1.4253.1.16.4.1.2 | DisplayString (SIZE(0..20)) | not-accessible | mandatory |
| rsmSubDivSize OBJECT-TYPE Size of each sub division in ROM in kilobytes | 1.3.6.1.4.1.4253.1.16.4.1.3 | INTEGER (0..1024) | not-accessible | mandatory |
| rsmSubDivOffset OBJECT-TYPE Starting address of each sub division in the ROM in HEX notation. | 1.3.6.1.4.1.4253.1.16.4.1.4 | OCTET STRING (SIZE(0..8)) | not-accessible | mandatory |
| rsmNumber OBJECT-TYPE Number of RSM rows in the following table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.16.5 | INTEGER | read-only | mandatory |
| rsmTable OBJECT-TYPE This table represents the information for each RSM card | 1.3.6.1.4.1.4253.1.16.6 | not-accessible | mandatory | |
| rsmEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.16.6.1 | not-accessible | mandatory | |
| rsmCardLocation OBJECT-TYPE Location of the RSM card. Valid values are: Local in the same chassis. | 1.3.6.1.4.1.4253.1.16.6.1.1 | CardLocation | read-only | mandatory |
| rsmCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.16.6.1.2 | CardShelf | read-only | mandatory |
| rsmCardSlot OBJECT-TYPE The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.16.6.1.3 | SlotInput | read-write | mandatory |
| rsmModelNum OBJECT-TYPE RSM's model number. | 1.3.6.1.4.1.4253.1.16.6.1.4 | DisplayString | read-only | mandatory |
| rsmOpticsMfgDate OBJECT-TYPE Date and Time of manufacturing of the optics on the RSM card. | 1.3.6.1.4.1.4253.1.16.6.1.5 | DateAndTime | not-accessible | mandatory |
| rsmSerialNum OBJECT-TYPE Serial # of the RSM card. | 1.3.6.1.4.1.4253.1.16.6.1.6 | SerialString | read-only | mandatory |
| rsmModelType OBJECT-TYPE Model type of the RSM. | 1.3.6.1.4.1.4253.1.16.6.1.7 | CardType | read-only | mandatory |
| rsmHWName OBJECT-TYPE Manufacturing Hardware name of the RSM Card. | 1.3.6.1.4.1.4253.1.16.6.1.8 | CardName | read-only | mandatory |
| rsmCardName OBJECT-TYPE User configurable card name. | 1.3.6.1.4.1.4253.1.16.6.1.9 | CardName | read-write | mandatory |
| rsmFWName OBJECT-TYPE RSM's Firmware Name. | 1.3.6.1.4.1.4253.1.16.6.1.10 | DisplayString | read-only | mandatory |
| rsmFWVersionID OBJECT-TYPE The current version string of the RSM FW code. | 1.3.6.1.4.1.4253.1.16.6.1.11 | VersionString | read-only | mandatory |
| rsmFWDate OBJECT-TYPE Date and Time of latest Firmware of the RSM card. | 1.3.6.1.4.1.4253.1.16.6.1.12 | DateAndTime | read-only | mandatory |
| rsmSetState OBJECT-TYPE Instruct the rsm to do a warmboot. A get on this will always return an other. | 1.3.6.1.4.1.4253.1.16.6.1.13 | RebootType | read-write | mandatory |
| rsmRxInsertionLoss OBJECT-TYPE Insertion loss for Rx Path. | 1.3.6.1.4.1.4253.1.16.6.1.14 | DisplayString | read-only | mandatory |
| rsmRxComInsertionLoss OBJECT-TYPE Insertion loss for Rx Com Path. | 1.3.6.1.4.1.4253.1.16.6.1.15 | DisplayString | read-only | mandatory |
| rsmWorkingWavelength OBJECT-TYPE The RSM ITU number. | 1.3.6.1.4.1.4253.1.16.6.1.16 | INTEGER | read-only | mandatory |
| rsmLinkAPathID OBJECT-TYPE Rsm LinkA Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path. | 1.3.6.1.4.1.4253.1.16.6.1.17 | PathIdName | read-write | mandatory |
| rsmLinkBPathID OBJECT-TYPE Rsm LinkB Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path. | 1.3.6.1.4.1.4253.1.16.6.1.18 | PathIdName | read-write | mandatory |
| rsmAdminState OBJECT-TYPE Administrative control over that rsm card. Default value is enable. When disabled, no alarms/events gets generated. | 1.3.6.1.4.1.4253.1.16.6.1.19 | INTEGER {disable(1), enable(2), na(3)} | read-write | mandatory |
| rsmCleiNum OBJECT-TYPE CLEI number of the rsm Card. | 1.3.6.1.4.1.4253.1.16.6.1.20 | DisplayString | read-only | mandatory |
| rsmNumPorts OBJECT-TYPE Total port numbers on each RSM card. | 1.3.6.1.4.1.4253.1.16.6.1.21 | INTEGER | read-only | mandatory |
| rsmPortTable OBJECT-TYPE This table represents the information for each RSM card's port. | 1.3.6.1.4.1.4253.1.16.7 | not-accessible | mandatory | |
| rsmPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.16.7.1 | not-accessible | mandatory | |
| rsmPortCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.16.7.1.1 | CardShelf | read-only | mandatory |
| rsmPortCardSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.1.16.7.1.2 | SlotInput | read-only | mandatory |
| rsmPortType OBJECT-TYPE Type of the RSM's port. The order is CLI compatible. | 1.3.6.1.4.1.4253.1.16.7.1.3 | INTEGER {localARx(1), localATx(2), localBRx(3), localBTx(4)} | read-only | mandatory |
| rsmConnCardType OBJECT-TYPE Module type connected to rsm port. The valid module types are OCM10G/OCME/OCMITU/OCMU. | 1.3.6.1.4.1.4253.1.16.7.1.4 | CardType | read-write | mandatory |
| rsmConnShelf OBJECT-TYPE The shelf the card conn to. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.16.7.1.5 | ShelfInput | read-write | mandatory |
| rsmConnSlot OBJECT-TYPE The slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0. | 1.3.6.1.4.1.4253.1.16.7.1.6 | SlotInput | read-write | mandatory |
| rsmConnPort OBJECT-TYPE Conn port for RSM's port. Only OCM10G/OCME/OCMITU/OCMU can be connected to RSM. The possible values are: OCM10G/OCME/OCMITU/OCMU: 3=CPE Tx, 4=CPE Rx | 1.3.6.1.4.1.4253.1.16.7.1.7 | INTEGER | read-write | mandatory |
| upsm OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.17 | |||
| upsmBootPromVer OBJECT-TYPE The current version string of the rsm Boot PROM code | 1.3.6.1.4.1.4253.1.17.1 | VersionString | not-accessible | mandatory |
| upsmROMSize OBJECT-TYPE Total Size of the ROM in Kilobyes | 1.3.6.1.4.1.4253.1.17.2 | INTEGER (0..1024) | not-accessible | mandatory |
| upsmNumSubDiv OBJECT-TYPE Number of the subdivisions of the ROM. | 1.3.6.1.4.1.4253.1.17.3 | INTEGER (0..20) | not-accessible | mandatory |
| upsmSubDivTable OBJECT-TYPE This table represents the number of sub divisions and the size of each subdivision in ROM memory | 1.3.6.1.4.1.4253.1.17.4 | not-accessible | mandatory | |
| upsmSubDivEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.17.4.1 | not-accessible | mandatory | |
| upsmSubDivIndex OBJECT-TYPE Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM. | 1.3.6.1.4.1.4253.1.17.4.1.1 | INTEGER (0..20) | not-accessible | mandatory |
| upsmSubDivDescr OBJECT-TYPE Display Name of each Sub Division in ROM | 1.3.6.1.4.1.4253.1.17.4.1.2 | DisplayString (SIZE(0..20)) | not-accessible | mandatory |
| upsmSubDivSize OBJECT-TYPE Size of each sub division in ROM in kilobytes | 1.3.6.1.4.1.4253.1.17.4.1.3 | INTEGER (0..1024) | not-accessible | mandatory |
| upsmSubDivOffset OBJECT-TYPE Starting address of each sub division in the ROM in HEX notation. | 1.3.6.1.4.1.4253.1.17.4.1.4 | OCTET STRING (SIZE(0..8)) | not-accessible | mandatory |
| upsmNumber OBJECT-TYPE Number of UPSM rows in the following table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.17.5 | INTEGER | read-only | mandatory |
| upsmTable OBJECT-TYPE This table represents the information for each UPSM card | 1.3.6.1.4.1.4253.1.17.6 | not-accessible | mandatory | |
| upsmEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.17.6.1 | not-accessible | mandatory | |
| upsmCardLocation OBJECT-TYPE Location of the UPSM card. Valid values are: Local in the same chassis. | 1.3.6.1.4.1.4253.1.17.6.1.1 | CardLocation | read-only | mandatory |
| upsmCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.17.6.1.2 | INTEGER | read-only | mandatory |
| upsmCardSlot OBJECT-TYPE The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.17.6.1.3 | INTEGER | read-write | mandatory |
| upsmModelNum OBJECT-TYPE UPSM's model number. | 1.3.6.1.4.1.4253.1.17.6.1.4 | DisplayString | read-only | mandatory |
| upsmOpticsMfgDate OBJECT-TYPE Date and Time of manufacturing of the optics on the UPSM card. | 1.3.6.1.4.1.4253.1.17.6.1.5 | DateAndTime | not-accessible | mandatory |
| upsmSerialNum OBJECT-TYPE Serial # of the UPSM card. | 1.3.6.1.4.1.4253.1.17.6.1.6 | SerialString | read-only | mandatory |
| upsmModelType OBJECT-TYPE Model type of the UPSM. | 1.3.6.1.4.1.4253.1.17.6.1.7 | CardType | read-only | mandatory |
| upsmHWName OBJECT-TYPE Manufacturing Hardware name of the UPSM Card. | 1.3.6.1.4.1.4253.1.17.6.1.8 | CardName | read-only | mandatory |
| upsmCardName OBJECT-TYPE User configurable card name. | 1.3.6.1.4.1.4253.1.17.6.1.9 | CardName | read-write | mandatory |
| upsmFWName OBJECT-TYPE UPSM's Firmware Name. | 1.3.6.1.4.1.4253.1.17.6.1.10 | DisplayString | read-only | mandatory |
| upsmFWVersionID OBJECT-TYPE The current version string of the UPSM FW code. | 1.3.6.1.4.1.4253.1.17.6.1.11 | VersionString | read-only | mandatory |
| upsmFWDate OBJECT-TYPE Date and Time of latest Firmware of the UPSM card. | 1.3.6.1.4.1.4253.1.17.6.1.12 | DateAndTime | read-only | mandatory |
| upsmSetState OBJECT-TYPE Instruct the upsm to do a warmboot. A get on this will always return an other. | 1.3.6.1.4.1.4253.1.17.6.1.13 | RebootType | read-write | mandatory |
| upsmRxInsertionLoss OBJECT-TYPE Insertion loss for Rx Path. | 1.3.6.1.4.1.4253.1.17.6.1.14 | DisplayString | read-only | mandatory |
| upsmTxInsertionLoss OBJECT-TYPE Insertion loss for Tx Path. | 1.3.6.1.4.1.4253.1.17.6.1.15 | DisplayString | read-only | mandatory |
| upsmMarginForSwitch OBJECT-TYPE The UPSM switching threshold for protection switch to occur. The limit is from -32 to -6. Switching threshold must be 1 dBm or more less than the minimum switch power. | 1.3.6.1.4.1.4253.1.17.6.1.16 | INTEGER (-32..-6) | read-write | mandatory |
| upsmMinProtPowerForSwitch OBJECT-TYPE The minimum protection link power to allow protection switch to function. The limit is from -30 to -5. This value should be 1 dBm or more greater than the switch margin. | 1.3.6.1.4.1.4253.1.17.6.1.17 | INTEGER (-30..-5) | read-write | mandatory |
| upsmDebounce OBJECT-TYPE The number of times to measure low power condition before performing protection switch. | 1.3.6.1.4.1.4253.1.17.6.1.18 | INTEGER | read-only | mandatory |
| upsmBlackOutTime OBJECT-TYPE The time after protection switch before allowing another protection switch. | 1.3.6.1.4.1.4253.1.17.6.1.19 | INTEGER | read-only | mandatory |
| upsmSwitch OBJECT-TYPE The Link switch control. switchToLinkA or switchToLinkB option would disable auto switch functionality. Auto switch functionality can be turned on by setting to enableAutoSwitch option | 1.3.6.1.4.1.4253.1.17.6.1.20 | INTEGER {other(1), switchToLinkA(2), switchToLinkB(3), toggle(4), enableAutoSwitch(6), enableSwitchtoLinkA(7), enableSwitchtoLinkB(8)} | read-write | mandatory |
| upsmLinkAPathID OBJECT-TYPE Upsm LinkA Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path. | 1.3.6.1.4.1.4253.1.17.6.1.21 | PathIdName | read-write | mandatory |
| upsmLinkBPathID OBJECT-TYPE Upsm LinkB Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path. | 1.3.6.1.4.1.4253.1.17.6.1.22 | PathIdName | read-write | mandatory |
| upsmAdminState OBJECT-TYPE Administrative control over that upsm card. Default value is enable. When disabled, no alarms/events gets generated. | 1.3.6.1.4.1.4253.1.17.6.1.23 | INTEGER {disable(1), enable(2), na(3)} | read-write | mandatory |
| upsmCleiNum OBJECT-TYPE CLEI number of the upsm Card. | 1.3.6.1.4.1.4253.1.17.6.1.24 | DisplayString | read-only | mandatory |
| upsmSwitchState OBJECT-TYPE The switching state. Switching state may be either auto or forced. The auto state means automatic switching is enabled. Forced state means swithcing is disabled and has been forced to the current active link. | 1.3.6.1.4.1.4253.1.17.6.1.25 | INTEGER {auto(1), forced(2)} | read-only | mandatory |
| upsmNumPorts OBJECT-TYPE Total port numbers on each UPSM card. | 1.3.6.1.4.1.4253.1.17.6.1.26 | INTEGER | read-only | mandatory |
| upsmPortTable OBJECT-TYPE This table represents the information for each UPSM card's port. | 1.3.6.1.4.1.4253.1.17.7 | not-accessible | mandatory | |
| upsmPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.17.7.1 | not-accessible | mandatory | |
| upsmPortCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.17.7.1.1 | CardShelf | read-only | mandatory |
| upsmPortCardSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.1.17.7.1.2 | SlotInput | read-only | mandatory |
| upsmPortType OBJECT-TYPE Type of the UPSM's port. The order is CLI compatible. | 1.3.6.1.4.1.4253.1.17.7.1.3 | INTEGER {linkATx(1), linkARx(2), linkBTx(3), linkBRx(4), localTx(5), localRx(6)} | read-only | mandatory |
| upsmConnLocation OBJECT-TYPE The chassis's location of the card conn to. | 1.3.6.1.4.1.4253.1.17.7.1.4 | CardLocation | read-write | mandatory |
| upsmConnIpAddress OBJECT-TYPE IpAddress of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the IP address of the node | 1.3.6.1.4.1.4253.1.17.7.1.5 | IpAddress | read-write | mandatory |
| upsmConnChassisID OBJECT-TYPE Chassis ID of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the chassis Id of the local node | 1.3.6.1.4.1.4253.1.17.7.1.6 | DisplayString (SIZE(0..16)) | read-write | mandatory |
| upsmConnSystemName OBJECT-TYPE System Name of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the sysetem name of the local node. | 1.3.6.1.4.1.4253.1.17.7.1.7 | DisplayString (SIZE(0..32)) | read-write | mandatory |
| upsmConnCardType OBJECT-TYPE Module type connected to upsm port. | 1.3.6.1.4.1.4253.1.17.7.1.8 | CardType | read-write | mandatory |
| upsmConnPort OBJECT-TYPE Conn port for UPSM's port. Possible values based on card types that can connect to UPSM are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. | 1.3.6.1.4.1.4253.1.17.7.1.9 | INTEGER | read-write | mandatory |
| upsmConnShelf OBJECT-TYPE The shelf the card conn to. Valid values are: 1 to 2. | 1.3.6.1.4.1.4253.1.17.7.1.10 | ShelfInput | read-write | mandatory |
| upsmConnSlot OBJECT-TYPE The slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0. | 1.3.6.1.4.1.4253.1.17.7.1.11 | SlotInput | read-write | mandatory |
| mcmesc OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.18 | |||
| mcmescBootPromVer OBJECT-TYPE The current version string of the mcmesc Boot PROM code | 1.3.6.1.4.1.4253.1.18.1 | VersionString | not-accessible | mandatory |
| mcmescROMSize OBJECT-TYPE Total Size of the ROM in Kilobyes | 1.3.6.1.4.1.4253.1.18.2 | INTEGER (0..1024) | not-accessible | mandatory |
| mcmescNumSubDiv OBJECT-TYPE Number of the subdivisions of the ROM. | 1.3.6.1.4.1.4253.1.18.3 | INTEGER (0..20) | not-accessible | mandatory |
| mcmescSubDivTable OBJECT-TYPE This table represents the number of sub divisions and the size of each subdivision in ROM memory | 1.3.6.1.4.1.4253.1.18.4 | not-accessible | mandatory | |
| mcmescSubDivEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.18.4.1 | not-accessible | mandatory | |
| mcmescSubDivIndex OBJECT-TYPE Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM. | 1.3.6.1.4.1.4253.1.18.4.1.1 | INTEGER (0..20) | not-accessible | mandatory |
| mcmescSubDivDescr OBJECT-TYPE Display Name of each Sub Division in ROM | 1.3.6.1.4.1.4253.1.18.4.1.2 | DisplayString (SIZE(0..20)) | not-accessible | mandatory |
| mcmescSubDivSize OBJECT-TYPE Size of each sub division in ROM in kilobytes | 1.3.6.1.4.1.4253.1.18.4.1.3 | INTEGER (0..1024) | not-accessible | mandatory |
| mcmescSubDivOffset OBJECT-TYPE Starting address of each sub division in the ROM in HEX notation. | 1.3.6.1.4.1.4253.1.18.4.1.4 | OCTET STRING (SIZE(0..8)) | not-accessible | mandatory |
| mcmescNumber OBJECT-TYPE Number of rows in the following table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.18.5 | INTEGER | read-only | mandatory |
| mcmescTable OBJECT-TYPE This table represents the information for each mcmesc module | 1.3.6.1.4.1.4253.1.18.6 | not-accessible | mandatory | |
| mcmescEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.18.6.1 | not-accessible | mandatory | |
| mcmescCardLocation OBJECT-TYPE Location of the mcmesc Module. | 1.3.6.1.4.1.4253.1.18.6.1.1 | CardLocation | read-only | mandatory |
| mcmescCardShelf OBJECT-TYPE The shelf of the mcmesc is in. Valid values are: 1..2 | 1.3.6.1.4.1.4253.1.18.6.1.2 | CardShelf | read-only | mandatory |
| mcmescCardSlot OBJECT-TYPE The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.18.6.1.3 | SlotInput | read-write | mandatory |
| mcmescMfgDate OBJECT-TYPE Date and Time of calibration of the mcmesc card | 1.3.6.1.4.1.4253.1.18.6.1.4 | DateAndTime | read-only | mandatory |
| mcmescSerialNum OBJECT-TYPE Serial # of the mcmesc card. | 1.3.6.1.4.1.4253.1.18.6.1.5 | SerialString | read-only | mandatory |
| mcmescModelType OBJECT-TYPE Model type of the mcmesc | 1.3.6.1.4.1.4253.1.18.6.1.6 | CardType | read-only | mandatory |
| mcmescModelNum OBJECT-TYPE Model number of the MCMESC card. Up to 15 characters | 1.3.6.1.4.1.4253.1.18.6.1.7 | DisplayString | read-only | mandatory |
| mcmescName OBJECT-TYPE Display (Network) name of the MCMESC Module | 1.3.6.1.4.1.4253.1.18.6.1.8 | CardName | read-write | mandatory |
| mcmescHWName OBJECT-TYPE Display Hardware name of the MCMESC Card. | 1.3.6.1.4.1.4253.1.18.6.1.9 | CardName | read-only | mandatory |
| mcmescNumPorts OBJECT-TYPE Total port numbers of MCM module. | 1.3.6.1.4.1.4253.1.18.6.1.10 | INTEGER | read-only | mandatory |
| mcmescFWVersionID OBJECT-TYPE The current version string of the MCMESC FW code | 1.3.6.1.4.1.4253.1.18.6.1.11 | VersionString | read-only | mandatory |
| mcmesc2ndFWVersionID OBJECT-TYPE The version string of the MCMESC second FW code | 1.3.6.1.4.1.4253.1.18.6.1.12 | VersionString | read-only | mandatory |
| mcmescFPGAVersionID OBJECT-TYPE The current version string of the MCMESC FPGA code | 1.3.6.1.4.1.4253.1.18.6.1.13 | VersionString | read-only | mandatory |
| mcmesc2ndFPGAVersionID OBJECT-TYPE The version string of the MCMESC second FPGA code | 1.3.6.1.4.1.4253.1.18.6.1.14 | VersionString | read-only | mandatory |
| mcmescBoardSerialNum OBJECT-TYPE Serial # of the MCMESC board. | 1.3.6.1.4.1.4253.1.18.6.1.15 | SerialString | read-only | mandatory |
| mcmescBoardVersionID OBJECT-TYPE The version string of the MCMESC board | 1.3.6.1.4.1.4253.1.18.6.1.16 | VersionString | read-only | mandatory |
| mcmescDaughterBoard1SerialNum OBJECT-TYPE Serial # of the MCMESC daughter board 1. | 1.3.6.1.4.1.4253.1.18.6.1.17 | SerialString | read-only | mandatory |
| mcmescDaughterBoard1VersionID OBJECT-TYPE The version string of the MCMESC daughter board 1 | 1.3.6.1.4.1.4253.1.18.6.1.18 | VersionString | read-only | mandatory |
| mcmescDaughterBoard2SerialNum OBJECT-TYPE Serial # of the MCMESC daughter board 2. | 1.3.6.1.4.1.4253.1.18.6.1.19 | SerialString | read-only | mandatory |
| mcmescDaughterBoard2VersionID OBJECT-TYPE The version string of the MCMESC daughter board 2 | 1.3.6.1.4.1.4253.1.18.6.1.20 | VersionString | read-only | mandatory |
| mcmescCleiNum OBJECT-TYPE CLEI number of the MCMESC Card. | 1.3.6.1.4.1.4253.1.18.6.1.21 | DisplayString | read-only | mandatory |
| mcmescLinkWavelength OBJECT-TYPE Link Wavelength of the MCMESC card | 1.3.6.1.4.1.4253.1.18.6.1.22 | DisplayString | read-only | mandatory |
| mcmescLinkSfpSerialNum OBJECT-TYPE Link port's SFP serial number. | 1.3.6.1.4.1.4253.1.18.6.1.23 | SfpSerialString | read-only | mandatory |
| mcmescAdminState OBJECT-TYPE Administrative control over that MCMESC card. Default value is enable. When disabled, no alarms/events gets generated. | 1.3.6.1.4.1.4253.1.18.6.1.24 | INTEGER {disable(1), enable(2), na(3)} | read-write | mandatory |
| mcmescLinkName OBJECT-TYPE Link name for fiber between the local and the remote MCMESC card. | 1.3.6.1.4.1.4253.1.18.6.1.25 | LinkName | read-write | mandatory |
| mcmescPathID OBJECT-TYPE Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path. | 1.3.6.1.4.1.4253.1.18.6.1.26 | PathIdName | read-write | mandatory |
| mcmescOverride OBJECT-TYPE MPM overrides the settings stored on MCMESC card upon detecting it. Default value is no. Not applicable to remote MCMESC. | 1.3.6.1.4.1.4253.1.18.6.1.27 | INTEGER {yes(1), no(2), na(3)} | read-write | mandatory |
| mcmescPerfInterval OBJECT-TYPE The interval, in seconds, in which MCMESC collects the performance data, ranging 60 to 3600. | 1.3.6.1.4.1.4253.1.18.6.1.28 | INTEGER (60..3600) | read-write | mandatory |
| mcmescCpeRxSigLowThreshold OBJECT-TYPE The threshold of reporting CPE port Rx signal low alarm, in dBm, ranging from -29 to -7. | 1.3.6.1.4.1.4253.1.18.6.1.29 | INTEGER (-29..-7) | read-write | mandatory |
| mcmescLinkRxSigLowThreshold OBJECT-TYPE The threshold of reporting Link Rx signal low alarm, in dBm, ranging from -29 to -7. | 1.3.6.1.4.1.4253.1.18.6.1.30 | INTEGER (-29..-7) | read-write | mandatory |
| mcmescCpeErrEventThreshold OBJECT-TYPE The threshold of reporting CPE error event, in the form of 1.0E-x. Only x needs to be set and will be read. The range of x is from 5 to 15, however, input should be an absolute value if using mib browser. This threshold should be lower than the value of mcmescCpeErrAlarmThreshold, i.e., the absolute value should be higher than of mcmescCpeErrAlarmThreshold. | 1.3.6.1.4.1.4253.1.18.6.1.31 | INTEGER (5..15) | read-write | mandatory |
| mcmescCpeErrAlarmThreshold OBJECT-TYPE The threshold of reporting CPE error alarm, in the form of 1.0E-x. The range of x is from 4 to 14, however, input should be an absolute value if using mib browser. This threshold should be higher than the value of mcmescCpeErrEventThreshold, i.e., the absolute value should be lower than of mcmescCpeErrEventThreshold. | 1.3.6.1.4.1.4253.1.18.6.1.32 | INTEGER (4..14) | read-write | mandatory |
| mcmescLinkErrEventThreshold OBJECT-TYPE The threshold of reporting LINK error event, in the form of 1.0E-x. The range of x is from 5 to 15, however, input should be an absolute value if using mib browser. This threshold should be lower than the value of mcmescLinkErrAlarmThreshold, i.e., the absolute value should be higher than of mcmescLinkErrAlarmThreshold. | 1.3.6.1.4.1.4253.1.18.6.1.33 | INTEGER (5..15) | read-write | mandatory |
| mcmescLinkErrAlarmThreshold OBJECT-TYPE The threshold of reporting LINK error alarm, in the form of 1.0E-x. The range of x is from 4 to 14, however, input should be an absolute value if using mib browser. This threshold should be higher than the value of mcmescLinkErrEventThreshold, i.e., the absolute value should be lower than of mcmescLinkErrEventThreshold. | 1.3.6.1.4.1.4253.1.18.6.1.34 | INTEGER (4..14) | read-write | mandatory |
| mcmescTestSequence OBJECT-TYPE Turn on or off the test-sequence on link. The operation will take place on the remote MCMESC if it's connected. | 1.3.6.1.4.1.4253.1.18.6.1.35 | FlagType | read-write | mandatory |
| mcmescConnMuxShelf OBJECT-TYPE The connected W4CM/UPSM shelf. | 1.3.6.1.4.1.4253.1.18.6.1.36 | ShelfInput | read-only | mandatory |
| mcmescConnMuxSlot OBJECT-TYPE The connected W4CM/UPSM slot. | 1.3.6.1.4.1.4253.1.18.6.1.37 | SlotInput | read-only | mandatory |
| mcmescConnMuxPort OBJECT-TYPE The connected W4CM/UPSM port. W4CM: 1=1470/1510, 2=1490/1530, 3=15501590/, 4=1570/1610, 5=EXP, 6=IN/OUT; UPSM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. | 1.3.6.1.4.1.4253.1.18.6.1.38 | INTEGER | read-only | mandatory |
| mcmescConnDemuxShelf OBJECT-TYPE The connected W4CD/UPSM shelf. | 1.3.6.1.4.1.4253.1.18.6.1.39 | ShelfInput | read-only | mandatory |
| mcmescConnDemuxSlot OBJECT-TYPE The connected W4CD/UPSM slot. | 1.3.6.1.4.1.4253.1.18.6.1.40 | SlotInput | read-only | mandatory |
| mcmescConnDemuxPort OBJECT-TYPE The connected W4CD/UPSM port. W4CD: 1=1470/1510, 2=1490/1530, 3=15501590/, 4=1570/1610, 5=EXP, 6=IN/OUT; UPSM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. | 1.3.6.1.4.1.4253.1.18.6.1.41 | INTEGER | read-only | mandatory |
| mcmescConnTxOcmShelf OBJECT-TYPE The connected OCM shelf (from MCMESC's Link Tx). | 1.3.6.1.4.1.4253.1.18.6.1.42 | ShelfInput | read-only | mandatory |
| mcmescConnTxOcmSlot OBJECT-TYPE The connected OCM slot (from MCMESC's Link Tx). | 1.3.6.1.4.1.4253.1.18.6.1.43 | SlotInput | read-only | mandatory |
| mcmescConnTxOcmPort OBJECT-TYPE The connected OCM port (from MCMESC's Link Tx). 3=OCM's CPE-Tx, 4=OCM's Rx. Only 4 is valid. | 1.3.6.1.4.1.4253.1.18.6.1.44 | INTEGER {cpetx(3), cperx(4)} | read-only | mandatory |
| mcmescConnTxOcmShelfSlot OBJECT-TYPE Add a connection from MCMESC Link-Tx to an OCM CPE-Rx by specifying the OCM's shelf and slot. The format is shlef,slot. If either MCMESC Link-Tx or specified OCM CPE-Rx has already had connection, an error will be returned. If the card specified by shelf,slot is not ocm type, an error will be returned. A get on this variable will always return 0,0. | 1.3.6.1.4.1.4253.1.18.6.1.45 | DisplayString (SIZE(0..10)) | read-write | mandatory |
| mcmescConnTxOcmDelete OBJECT-TYPE Delete a connection from MCMESC Link-Tx to an OCM CPE-Rx. If MCMESC's Link-Tx has no connection with any OCM's CPE-Rx, an error will be returned. A get on this variable will always return an other. | 1.3.6.1.4.1.4253.1.18.6.1.46 | INTEGER {other(1), yes(2)} | read-write | mandatory |
| mcmescConnRxOcmShelf OBJECT-TYPE The connected OCM shelf (from MCMESC's Link Rx). | 1.3.6.1.4.1.4253.1.18.6.1.47 | ShelfInput | read-only | mandatory |
| mcmescConnRxOcmSlot OBJECT-TYPE The connected OCM slot (from MCMESC's Link Rx). | 1.3.6.1.4.1.4253.1.18.6.1.48 | SlotInput | read-write | mandatory |
| mcmescConnRxOcmPort OBJECT-TYPE The connected OCM port (from MCMESC's Link Rx). 3=OCM's CPE-Tx, 4=OCM's Rx. Only 3 is valid. | 1.3.6.1.4.1.4253.1.18.6.1.49 | INTEGER {cpetx(3), cperx(4)} | read-write | mandatory |
| mcmescConnRxOcmShelfSlot OBJECT-TYPE Add a connection from MCMESC Link-Rx to an OCM CPE-Tx by specifying the OCM's shelf and slot. The format is shlef,slot. If either MCMESC Link-Tx or specified OCM CPE-Rx has already had connection, an error will be returned. If the card specified by shelf,slot is not ocm type, an error will be returned. A get on this variable will always return 0,0 | 1.3.6.1.4.1.4253.1.18.6.1.50 | DisplayString (SIZE(0..10)) | read-write | mandatory |
| mcmescConnRxOcmDelete OBJECT-TYPE Delete a connection from MCMESC Link-Rx to an OCM CPE-Tx. If MCMESC's Link-Rx has no connection with any OCM's CPE-Tx, an error will be returned. A get on this variable will always return an other. | 1.3.6.1.4.1.4253.1.18.6.1.51 | INTEGER {other(1), yes(2)} | read-write | mandatory |
| mcmescSetState OBJECT-TYPE Instruct the mcmesc card to do either a reset or loopback. A get on this will always return an other. If the card is in self-test, an error will be returned. If the card is already in any loopback, and try to turn on another loopback, an error will be returned. | 1.3.6.1.4.1.4253.1.18.6.1.52 | INTEGER {other(1), resetWithCurrentConfiguration(2), nearEndCardLoopback(3), networkCardLoopback(4), nearEndPort1Loopback(5), nearEndPort2Loopback(6), nearEndPort3Loopback(7), nearEndPort4Loopback(8), nearEndPort5Loopback(9), nearEndPort6Loopback(10), nearEndPort7Loopback(11), nearEndPort8Loopback(12), nearEndPort9Loopback(13), nearEndPort10Loopback(14), nearEndPort11Loopback(15), nearEndPort12Loopback(16), networkPort1Loopback(17), networkPort2Loopback(18), networkPort3Loopback(19), networkPort4Loopback(20), networkPort5Loopback(21), networkPort6Loopback(22), networkPort7Loopback(23), networkPort8Loopback(24), networkPort9Loopback(25), networkPort10Loopback(26), networkPort11Loopback(27), networkPort12Loopback(28), disableLoopback(29)} | read-write | mandatory |
| mcmescLinkClrErrCount OBJECT-TYPE Instruct the mcmesc card to clear the bit-error count for link port. A get on this will always return an other. | 1.3.6.1.4.1.4253.1.18.6.1.53 | INTEGER {other(1), clearErrCount(2)} | read-write | mandatory |
| mcmescPortNumber OBJECT-TYPE Number of MCMESC rows in the following table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.18.7 | INTEGER | read-only | mandatory |
| mcmescPortTable OBJECT-TYPE This table represents the information for each MCMESC module's port. | 1.3.6.1.4.1.4253.1.18.8 | not-accessible | mandatory | |
| mcmescPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.18.8.1 | not-accessible | mandatory | |
| mcmescPortCardLocation OBJECT-TYPE Location of the MCMESC port. Valid values are: Local in the same chassis, or remote to this chassis. | 1.3.6.1.4.1.4253.1.18.8.1.1 | CardLocation | read-only | mandatory |
| mcmescPortCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1..2. | 1.3.6.1.4.1.4253.1.18.8.1.2 | CardShelf | read-only | mandatory |
| mcmescPortCardSlot OBJECT-TYPE The slot within the shelf the Module is in. Valid values are: 1 to 17. | 1.3.6.1.4.1.4253.1.18.8.1.3 | SlotInput | read-only | mandatory |
| mcmescPortIndex OBJECT-TYPE CPE port's index. Valid values are: 1 to 12. | 1.3.6.1.4.1.4253.1.18.8.1.4 | INTEGER | read-only | mandatory |
| mcmescPortSfpSerialNum OBJECT-TYPE CPE port's SFP serial number. | 1.3.6.1.4.1.4253.1.18.8.1.5 | SfpSerialString | read-only | mandatory |
| mcmescPortConnectionState OBJECT-TYPE CPE port's connection status. | 1.3.6.1.4.1.4253.1.18.8.1.6 | INTEGER {disabled(1), enabled(2)} | read-write | mandatory |
| mcmescPortClrErrCount OBJECT-TYPE Instruct the mcmesc card to clear the bit-error count for a CPE port. A get on this will always return an other. | 1.3.6.1.4.1.4253.1.18.8.1.7 | INTEGER {other(1), clearErrCount(2)} | read-write | mandatory |
| systemConfig OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.21 | |||
| sysAddCard OBJECT-TYPE Add card operation given type, shelf, slot, and optionally sub card type. The format is (type,shelf, slot[,optional]). If the fourth optional parameter is present, for OCMITU/OCMU, its value should be 1 to indicate OCMITU/OCMU with CSIM; for MCMESC, its value should be 0 or 1 to indicate MPM will not overide or will override the settings stored on MCMESC upon detecting it. Different types of card: OCMU: 2 //with or without csim module OCMI: 3 //with or without csim module OFCM: 4 OFCD: 5 FADM: 6 MCMT1: 8 W4CD: 10 W2CM/D: 13 OSAM: 20 W4CM: 21 RSM: 22 UPSM: 23 OCME: 24 OCM10G: 27 OSAM-LP: 29 OSAM-HP: 30 MCMESC: 33 WFADM: 34 MCME1: 35 MD100-1: 36 MD100-40: 37 TAP: 38 MD100-5 39 MD100-10 40 OCM10GLR 41 BD-4 42 BP-10 43 DMM 45 BP-5 46 OSC 48 OCM2 49 OCM10GF 50 OCM2-4G 51 OET 52 UOB 53 FC8G 54 MD100P 55 CWDM_BD4 56 For example, to add a FADM card in shelf 1, slot 8, this variable will be set to 6,1,8. To add an OCMI card with colorsim module in shelf 1, slot 7, this variable will be set to 3,1,7,1. To add an MCMESC card with override option in shelf 1, slot 7, this variable will be set to 33,1,7,1. A get on this will return 0,0,0,0 | 1.3.6.1.4.1.4253.1.21.1 | DisplayString (SIZE(0..10)) | read-write | mandatory |
| sysAlarmCtrl OBJECT-TYPE The Master Control for Alarms. Will enable or disable all external and visual alarms of the system. The default state is enable. | 1.3.6.1.4.1.4253.1.21.2 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| sysAlarmCritical OBJECT-TYPE Turns on or off all external critical audible and visual alarms. | 1.3.6.1.4.1.4253.1.21.3 | INTEGER {on(1), off(2)} | read-write | mandatory |
| sysAlarmMajor OBJECT-TYPE Turns on or off all external major and minor audible and visual alarms. | 1.3.6.1.4.1.4253.1.21.4 | INTEGER {on(1), off(2)} | read-write | mandatory |
| sysAlarmSerial OBJECT-TYPE Enables or disables the flow of TL1 alarms to the serial port. | 1.3.6.1.4.1.4253.1.21.5 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| sysAlarmAutoCutoff OBJECT-TYPE Enables or disables the AutoCutoff feature for dry-contact alarm closures | 1.3.6.1.4.1.4253.1.21.6 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| sysAddRoute OBJECT-TYPE Add route operation given local shelf, local slot, destination IP address and route Type. The format is (shelf, slot, route Type, destination IP). Different types of route types are: external Route: 1 (Route to an external non LuxN node) internal Route: 2 (Route to a LuxN node in the network) For example, to add an internal route to a LuxN node with IP address 192.162.6.65 from local shelf 1, slot 6 this variable would be set to 1,6,3,192.162.6.65 For adding an external route, shelf & slot needs to be zero. For e.g To add an external route to destination address 192.168.9.99, this variable needs to be set to 0,0,192.168.9.99 A get on this will return 0,0,0,0 NO LONGER SUPPORTED, user now needs to use sysImnAddRoute | 1.3.6.1.4.1.4253.1.21.7 | DisplayString (SIZE(0..20)) | not-accessible | mandatory |
| sysDeleteRoute OBJECT-TYPE Delete route operation given local shelf, local slot & destination IP address . The format is (shelf, slot, destination IP). For example, to delete a route to a LuxN node with IP address 192.162.6.65 from local shelf 1, slot 6 this variable would be set to 1,6,192.162.6.65 A get on this will return 0,0,0 NO LONGER SUPPORTED, user now needs to use sysImnAddRoute | 1.3.6.1.4.1.4253.1.21.8 | DisplayString (SIZE(0..20)) | not-accessible | mandatory |
| sysSwitchByPathId OBJECT-TYPE Initiate UPSR switching by Path ID. | 1.3.6.1.4.1.4253.1.21.9 | PathIdName | read-write | mandatory |
| sysSwitchAll OBJECT-TYPE Switch all CC cards that have backup. | 1.3.6.1.4.1.4253.1.21.10 | INTEGER {yes(1), no(2)} | read-write | mandatory |
| sysAlarmMinor OBJECT-TYPE Turns on or off all external minor audible and visual alarms. | 1.3.6.1.4.1.4253.1.21.11 | INTEGER {on(1), off(2)} | read-write | mandatory |
| sysDelCfgDb OBJECT-TYPE Action to delete configuration database. MPM would reboot after the database is deleted. A get on it will return other | 1.3.6.1.4.1.4253.1.21.12 | INTEGER {other(1), delete(2)} | read-write | mandatory |
| sysImnAddRoute OBJECT-TYPE Add route operation. It takes destination IP address, IP mask and the route metric. The format is (destination IP, IP mask, routeMetric). A get on this will return 0.0.0.0,0.0.0.0,0 | 1.3.6.1.4.1.4253.1.21.13 | DisplayString (SIZE(0..20)) | read-write | mandatory |
| sysImnDeleteRoute OBJECT-TYPE Delete route operation. It takes destination IP address and IP mask. The format is (destination IP, IP mask=). A get on this will return 0.0.0.0,0.0.0.0 | 1.3.6.1.4.1.4253.1.21.14 | DisplayString (SIZE(0..20)) | read-write | mandatory |
| sysExtAlarmInputTable OBJECT-TYPE This table represents the input information for each external alarm indicator | 1.3.6.1.4.1.4253.1.21.17 | not-accessible | mandatory | |
| sysExtAlarmInputEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.21.17.1 | not-accessible | mandatory | |
| sysExtAlarmInputId OBJECT-TYPE Id of an external alarm indicator. Valid values are: 1 to 6 | 1.3.6.1.4.1.4253.1.21.17.1.1 | INTEGER | read-only | mandatory |
| sysExtAlarmInput OBJECT-TYPE Configurable value for an external alarm indicator. Default value is off. For the chassis with old sensor board, the value is na and is not settable. | 1.3.6.1.4.1.4253.1.21.17.1.2 | INTEGER {off(1), minor(2), major(3), critical(4), na(5)} | read-write | mandatory |
| sysExtAlarmInputName OBJECT-TYPE User configurable name for an external alarm input indicator. For the chassis with old sensor board, the value is na and is not settable. | 1.3.6.1.4.1.4253.1.21.17.1.3 | AlarmType | read-write | mandatory |
| sysAudioAlarm OBJECT-TYPE Mode for audio alarm. Default is off. For non-carrier-class chassis, it is na | 1.3.6.1.4.1.4253.1.21.18 | INTEGER {brief(1), test(2), continous(3), off(4), na(5)} | read-write | mandatory |
| sysAudioAlarmSeverity OBJECT-TYPE Controls for audio alarm. When the control is set to minor, it will go off for all minor and up alarms. Default is major. For non-carrier-class chassis, it is na. These control only make sense for audio alarm in brief or continous mode | 1.3.6.1.4.1.4253.1.21.19 | INTEGER {major(1), critical(2), minor(3), na(4)} | read-write | mandatory |
| sysRdbcopy OBJECT-TYPE Forces a database copy to the standby MPM. Reading this element will always return 'other'. This element can only be set to 'copydb'. If the standby MPM is present then a database copy will be initiated, otherwise an error will be return. | 1.3.6.1.4.1.4253.1.21.20 | INTEGER {other(1), copydb(2)} | read-write | mandatory |
| sysRdbcopyStatus OBJECT-TYPE Displays the percentage done for forced database copies. No value is returned if a forced database copy is not in progress. | 1.3.6.1.4.1.4253.1.21.21 | INTEGER | read-only | mandatory |
| sysSDMRequestsQueued OBJECT-TYPE Displays the number of requests in the SDM queue. | 1.3.6.1.4.1.4253.1.21.22 | INTEGER | read-only | mandatory |
| sysModuleupdateJobsWaiting OBJECT-TYPE Displays the number of module updates jobs from the current request that must wait until one or more of the jobs progressing completes. This element will only be returned if one or more module update jobs are in progress. | 1.3.6.1.4.1.4253.1.21.23 | INTEGER | read-only | mandatory |
| sysModuleupdateJobsTable OBJECT-TYPE This table defines the module update jobs in progress. Table entries will only be reutrned if one for more module update jobs are in progress. | 1.3.6.1.4.1.4253.1.21.24 | not-accessible | mandatory | |
| sysModuleupdateJobsEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.21.24.1 | not-accessible | mandatory | |
| sysModupdShelf OBJECT-TYPE Shelf of the module being updated. For remote updates this will be the shelf of the local module through the update occurs. | 1.3.6.1.4.1.4253.1.21.24.1.1 | INTEGER | read-only | mandatory |
| sysModupdSlot OBJECT-TYPE Slot of the module being updated. For remote updates this will be the slot of the local module through the update occurs. | 1.3.6.1.4.1.4253.1.21.24.1.2 | INTEGER | read-only | mandatory |
| sysModupdLocation OBJECT-TYPE Location (local or remote) of the module being updated | 1.3.6.1.4.1.4253.1.21.24.1.3 | CardLocation | read-only | mandatory |
| sysModupdRmtStation OBJECT-TYPE Remote station of the module being updated | 1.3.6.1.4.1.4253.1.21.24.1.4 | INTEGER | read-only | mandatory |
| sysModupdCardtype OBJECT-TYPE Type of module being updated. | 1.3.6.1.4.1.4253.1.21.24.1.5 | CardType | read-only | mandatory |
| sysModupdPercentDone OBJECT-TYPE Percentage of update completed. | 1.3.6.1.4.1.4253.1.21.24.1.6 | INTEGER | read-only | mandatory |
| sysSNMPKeepaliveEnable OBJECT-TYPE Enable or disable SNMP keep alive functionality. | 1.3.6.1.4.1.4253.1.21.25 | INTEGER {enabled(1), disabled(2)} | read-write | mandatory |
| sysSNMPKeepaliveInterval OBJECT-TYPE Set the SNMP keep alive interval in minutes. | 1.3.6.1.4.1.4253.1.21.26 | INTEGER (1..1440) | read-write | mandatory |
| topology OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.22 | |||
| topologyTable OBJECT-TYPE This table represents the link topology between local and remote cards | 1.3.6.1.4.1.4253.1.22.1 | not-accessible | mandatory | |
| topologyEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.22.1.1 | not-accessible | mandatory | |
| topologyNearEndCardShelf OBJECT-TYPE Shelf of the near end card. | 1.3.6.1.4.1.4253.1.22.1.1.1 | CardShelf | read-only | mandatory |
| topologyNearEndCardSlot OBJECT-TYPE Slot of the near end card. Input 0 will delete the topology link. | 1.3.6.1.4.1.4253.1.22.1.1.2 | CardSlot | read-write | mandatory |
| topologyNearEndCardPortIndex OBJECT-TYPE Near end optical link port. | 1.3.6.1.4.1.4253.1.22.1.1.3 | PortIndex | read-only | mandatory |
| topologyNearEndCardType OBJECT-TYPE Card type of the near end card. | 1.3.6.1.4.1.4253.1.22.1.1.4 | CardType | read-only | mandatory |
| topologyFarEndChassisID OBJECT-TYPE Chassis ID of the far end chassis. Part of manufacturing info | 1.3.6.1.4.1.4253.1.22.1.1.5 | NodeName | read-only | mandatory |
| topologyFarEndSystemName OBJECT-TYPE Name of the far end node/chassis. Not supported for remote TMM masters. | 1.3.6.1.4.1.4253.1.22.1.1.6 | NodeName | read-only | mandatory |
| topologyFarEndNodeIpAddress OBJECT-TYPE IpAddress of the far end chassis. Not supported for remote TMM masters. | 1.3.6.1.4.1.4253.1.22.1.1.7 | IpAddress | read-only | mandatory |
| topologyFarEndNodeCardShelf OBJECT-TYPE Shelf of the far end module | 1.3.6.1.4.1.4253.1.22.1.1.8 | CardShelf | read-only | mandatory |
| topologyFarEndNodeCardSlot OBJECT-TYPE Slot of the far end module | 1.3.6.1.4.1.4253.1.22.1.1.9 | CardSlot | read-only | mandatory |
| topologyFarEndNodeCardPortIndex OBJECT-TYPE Far end optical link port. | 1.3.6.1.4.1.4253.1.22.1.1.10 | PortIndex | read-only | mandatory |
| topologyLinkStatus OBJECT-TYPE Status of the link to indicate if active or down | 1.3.6.1.4.1.4253.1.22.1.1.11 | INTEGER {down(1), active(2), standby(3)} | read-only | mandatory |
| topologyFarEndNodeCardType OBJECT-TYPE Card type of the far end card. | 1.3.6.1.4.1.4253.1.22.1.1.12 | CardType | read-only | mandatory |
| topologyDiscover OBJECT-TYPE An action to rediscover the complete topology A get would alway return other(1). | 1.3.6.1.4.1.4253.1.22.2 | INTEGER {other(1), discoverTopology(2)} | read-write | mandatory |
| routing OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.23 | |||
| routingTable OBJECT-TYPE This table represents dynamic and static routing information | 1.3.6.1.4.1.4253.1.23.1 | not-accessible | mandatory | |
| routingEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.23.1.1 | not-accessible | mandatory | |
| routeLocalCCShelf OBJECT-TYPE Shelf of the local CC card. | 1.3.6.1.4.1.4253.1.23.1.1.1 | CardShelf | not-accessible | mandatory |
| routeLocalCCSlot OBJECT-TYPE Slot of the local CC card. | 1.3.6.1.4.1.4253.1.23.1.1.2 | CardSlot | not-accessible | mandatory |
| routeIpDestAddress OBJECT-TYPE Destination IP address. Not supported for remote TMM masters. | 1.3.6.1.4.1.4253.1.23.1.1.3 | IpAddress | not-accessible | mandatory |
| routeDestType OBJECT-TYPE Destination route type. External means destination is not part of LuxN network. Internal means destination is one of the LuxN node | 1.3.6.1.4.1.4253.1.23.1.1.4 | INTEGER {externalRoute(1), internalRoute(2)} | not-accessible | mandatory |
| routeMode OBJECT-TYPE Is the route added statically(manually) or dynamically(automatic) | 1.3.6.1.4.1.4253.1.23.1.1.5 | INTEGER {static(1), dynamic(2)} | not-accessible | mandatory |
| imnDynamicRoutingTable OBJECT-TYPE This table represents IMN based dynamic routing information | 1.3.6.1.4.1.4253.1.23.2 | not-accessible | mandatory | |
| imnDynamicRoutingEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.23.2.1 | not-accessible | mandatory | |
| imnDynamicRouteIpDest OBJECT-TYPE Destination IP address. Not supported for remote TMM masters. | 1.3.6.1.4.1.4253.1.23.2.1.1 | IpAddress | read-only | mandatory |
| imnDynamicRouteIpMask OBJECT-TYPE Destination's IP mask address. Not supported for remote TMM masters. | 1.3.6.1.4.1.4253.1.23.2.1.2 | IpAddress | read-only | mandatory |
| imnDynamicRouteMetric OBJECT-TYPE Cost associated with this route. | 1.3.6.1.4.1.4253.1.23.2.1.3 | INTEGER (1..15) | read-only | mandatory |
| imnDynamicRouteNextHop OBJECT-TYPE Neighbour node of this route. | 1.3.6.1.4.1.4253.1.23.2.1.4 | IpAddress | read-only | mandatory |
| imnDynamicRouteSysName OBJECT-TYPE Destination system name associated with route. | 1.3.6.1.4.1.4253.1.23.2.1.5 | DisplayString (SIZE(0..20)) | read-only | mandatory |
| imnRouteUpdateTimer OBJECT-TYPE Time in seconds for the route table to get updated/propagated Default value is 30 seconds. | 1.3.6.1.4.1.4253.1.23.3 | INTEGER (1..254) | read-write | mandatory |
| imnRouteKeepAliveTimer OBJECT-TYPE Time in seconds before neighbors enter unreachable state after communication is lost. This value has to be greater than or equal to imnRouteUpdateTimer Default value is 60 seconds | 1.3.6.1.4.1.4253.1.23.4 | INTEGER (1..255) | read-write | mandatory |
| imnRouteUnReachableTimer OBJECT-TYPE Time in seconds before Neighbors in unreachable state are deleted from the route table. This value has to greater than or equal to imnRouteUpdateTimer Default value is 60 seconds | 1.3.6.1.4.1.4253.1.23.5 | INTEGER (1..255) | read-write | mandatory |
| imnRouteMode OBJECT-TYPE Enable/Disable IMN functionality. Default is disabled | 1.3.6.1.4.1.4253.1.23.6 | INTEGER {disabled(1), enable(2)} | read-write | mandatory |
| imnStaticRoutingTable OBJECT-TYPE This table represents IMN based static routing information | 1.3.6.1.4.1.4253.1.23.7 | not-accessible | mandatory | |
| imnStaticRoutingEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.23.7.1 | not-accessible | mandatory | |
| imnStaticRouteIpDest OBJECT-TYPE Destination IP address. Not supported for remote TMM masters. | 1.3.6.1.4.1.4253.1.23.7.1.1 | IpAddress | read-only | mandatory |
| imnStaticRouteIpMask OBJECT-TYPE Destination's IP mask address. Not supported for remote TMM masters. | 1.3.6.1.4.1.4253.1.23.7.1.2 | IpAddress | read-only | mandatory |
| imnStaticRouteMetric OBJECT-TYPE Cost associated with this route. | 1.3.6.1.4.1.4253.1.23.7.1.3 | INTEGER (1..15) | read-only | mandatory |
| imnRouteMaxMetric OBJECT-TYPE Maximum acceptable metric count before the routes gets dropped. Default value is 255. Ideally this value should be greater than imnStaticRouteMetric | 1.3.6.1.4.1.4253.1.23.8 | INTEGER | read-write | mandatory |
| ring OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.24 | |||
| ringNum OBJECT-TYPE Total number of ring configured in the list. | 1.3.6.1.4.1.4253.1.24.1 | INTEGER | read-only | mandatory |
| ringTable OBJECT-TYPE This table represent the ring information | 1.3.6.1.4.1.4253.1.24.2 | not-accessible | mandatory | |
| ringEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.24.2.1 | not-accessible | mandatory | |
| ringIndex OBJECT-TYPE The ringIndex and also the index of the ring table. | 1.3.6.1.4.1.4253.1.24.2.1.1 | INTEGER | not-accessible | mandatory |
| ringID OBJECT-TYPE RingID Name for UPSR. Empty string will remove and deassociate the RingID with the PathIDs. You always has one dummy entry for adding another ring. | 1.3.6.1.4.1.4253.1.24.2.1.2 | RingIdName | read-write | mandatory |
| ringPathID1 OBJECT-TYPE PathID 1 associate with this ring. | 1.3.6.1.4.1.4253.1.24.2.1.3 | PathIdName | read-write | mandatory |
| ringPathID2 OBJECT-TYPE PathID 2 associate with this ring. | 1.3.6.1.4.1.4253.1.24.2.1.4 | PathIdName | read-write | mandatory |
| ringPath1RemoteIP OBJECT-TYPE IP Address of the neighbor node associated with path 1 | 1.3.6.1.4.1.4253.1.24.2.1.5 | IpAddress | read-only | mandatory |
| ringPath1RemoteChassisId OBJECT-TYPE Chassis ID of the neighbor node associated with path 1 | 1.3.6.1.4.1.4253.1.24.2.1.6 | DisplayString (SIZE(0..16)) | read-only | mandatory |
| ringPath2RemoteIP OBJECT-TYPE IP Address of the neighbor node associated with path 2 | 1.3.6.1.4.1.4253.1.24.2.1.7 | IpAddress | read-only | mandatory |
| ringPath2RemoteChassisId OBJECT-TYPE Chassis ID of the neighbor node associated with path 2 | 1.3.6.1.4.1.4253.1.24.2.1.8 | DisplayString (SIZE(0..16)) | read-only | mandatory |
| tap OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.25 | |||
| tapNumber OBJECT-TYPE Number of TAP rows in the following table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.25.1 | INTEGER | read-only | mandatory |
| tapTable OBJECT-TYPE This table represents the information for each TAP module | 1.3.6.1.4.1.4253.1.25.2 | not-accessible | mandatory | |
| tapEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.25.2.1 | not-accessible | mandatory | |
| tapCardLocation OBJECT-TYPE Location of the module. Valid values are: Local in the same chassis, or remote to this chassis | 1.3.6.1.4.1.4253.1.25.2.1.1 | CardLocation | read-only | mandatory |
| tapCardShelf OBJECT-TYPE The shelf the card is in. | 1.3.6.1.4.1.4253.1.25.2.1.2 | CardShelf | read-only | mandatory |
| tapCardSlot OBJECT-TYPE The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.25.2.1.3 | SlotInput | read-write | mandatory |
| tapModelNum OBJECT-TYPE Model number for module. | 1.3.6.1.4.1.4253.1.25.2.1.4 | DisplayString | read-only | mandatory |
| tapMfgDate OBJECT-TYPE Date and Time of manufacturing of the module | 1.3.6.1.4.1.4253.1.25.2.1.5 | DateAndTime | not-accessible | mandatory |
| tapSerialNum OBJECT-TYPE Serial number of the module. | 1.3.6.1.4.1.4253.1.25.2.1.6 | SerialString | read-only | mandatory |
| tapModelType OBJECT-TYPE Model type of the module | 1.3.6.1.4.1.4253.1.25.2.1.7 | CardType | read-only | mandatory |
| tapName OBJECT-TYPE User configurable name of the module | 1.3.6.1.4.1.4253.1.25.2.1.8 | CardName | read-write | mandatory |
| tapFWVersionID OBJECT-TYPE The current version string of the FW code | 1.3.6.1.4.1.4253.1.25.2.1.9 | VersionString | read-only | mandatory |
| tapHWName OBJECT-TYPE Display Hardware name of the module. | 1.3.6.1.4.1.4253.1.25.2.1.10 | CardName | read-only | mandatory |
| tapPathID OBJECT-TYPE Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path. | 1.3.6.1.4.1.4253.1.25.2.1.11 | PathIdName | read-write | mandatory |
| tapAdminState OBJECT-TYPE Administrative control over that TAP card. Default value is enable. When disabled, no alarms/events gets generated. | 1.3.6.1.4.1.4253.1.25.2.1.12 | INTEGER {disable(1), enable(2), na(3)} | read-write | mandatory |
| tapCleiNum OBJECT-TYPE CLEI number for the module. | 1.3.6.1.4.1.4253.1.25.2.1.13 | DisplayString | read-only | mandatory |
| tapNumPorts OBJECT-TYPE Total port numbers on each TAP card. | 1.3.6.1.4.1.4253.1.25.2.1.14 | INTEGER | read-only | mandatory |
| voadm OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.26 | |||
| voadmNumber OBJECT-TYPE Number of rows in the voadm table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.26.1 | INTEGER | read-only | mandatory |
| voadmTable OBJECT-TYPE This table represents the information for each VOADM card | 1.3.6.1.4.1.4253.1.26.2 | not-accessible | mandatory | |
| voadmEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.26.2.1 | not-accessible | mandatory | |
| voadmCardLocation OBJECT-TYPE Location of the module. VOADM modules will always be seen as local modules. | 1.3.6.1.4.1.4253.1.26.2.1.1 | CardLocation | read-only | mandatory |
| voadmCardShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.26.2.1.2 | CardShelf | read-only | mandatory |
| voadmCardSlot OBJECT-TYPE The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.26.2.1.3 | SlotInput | read-write | mandatory |
| voadmSerialNum OBJECT-TYPE Module serial number. | 1.3.6.1.4.1.4253.1.26.2.1.4 | SerialString | read-only | mandatory |
| voadmModelNum OBJECT-TYPE Module model number. | 1.3.6.1.4.1.4253.1.26.2.1.5 | DisplayString | read-only | mandatory |
| voadmHwName OBJECT-TYPE Module hardware name. | 1.3.6.1.4.1.4253.1.26.2.1.6 | DisplayString | read-only | mandatory |
| voadmHwVersionID OBJECT-TYPE Module hardware version. | 1.3.6.1.4.1.4253.1.26.2.1.7 | VersionString | read-only | mandatory |
| voadmMfgDate OBJECT-TYPE Date and Time of manufacturing of the module | 1.3.6.1.4.1.4253.1.26.2.1.8 | DateAndTime | read-only | mandatory |
| voadmFwName OBJECT-TYPE Module firmware name. | 1.3.6.1.4.1.4253.1.26.2.1.9 | CardName | read-only | mandatory |
| voadmFwVersionID OBJECT-TYPE Firmware version. | 1.3.6.1.4.1.4253.1.26.2.1.10 | VersionString | read-only | mandatory |
| voadmFwDate OBJECT-TYPE Firmware release date and time. | 1.3.6.1.4.1.4253.1.26.2.1.11 | DateAndTime | read-only | mandatory |
| voadmAdminState OBJECT-TYPE Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module. | 1.3.6.1.4.1.4253.1.26.2.1.12 | INTEGER {disable(1), enable(2), na(3)} | read-write | mandatory |
| voadmModelType OBJECT-TYPE Model type of the module. | 1.3.6.1.4.1.4253.1.26.2.1.13 | CardType | read-only | mandatory |
| voadmName OBJECT-TYPE User configurable name of the module. | 1.3.6.1.4.1.4253.1.26.2.1.14 | CardName | read-write | mandatory |
| voadmSetState OBJECT-TYPE Instruct the module to do a warmboot. A get on this will always return 'other'. | 1.3.6.1.4.1.4253.1.26.2.1.15 | RebootType | read-write | mandatory |
| voadmPathID OBJECT-TYPE Path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path. | 1.3.6.1.4.1.4253.1.26.2.1.16 | PathIdName | read-write | mandatory |
| voadmCleiNum OBJECT-TYPE CLEI number of the module. | 1.3.6.1.4.1.4253.1.26.2.1.17 | DisplayString | read-only | mandatory |
| voadmActiveChannels OBJECT-TYPE Number of active channels connected to the module. The allowed inpu range depends on the module type: MD100-5 1 to 5 MD100-10 1 to 10 | 1.3.6.1.4.1.4253.1.26.2.1.18 | INTEGER | read-write | mandatory |
| voadmStartItu OBJECT-TYPE First ITU channel supported by the module. | 1.3.6.1.4.1.4253.1.26.2.1.19 | INTEGER | read-only | mandatory |
| voadmEndItu OBJECT-TYPE Last ITU channel supported by the module. | 1.3.6.1.4.1.4253.1.26.2.1.20 | INTEGER | read-only | mandatory |
| voadmNumPorts OBJECT-TYPE Total port numbers on each VOADM card. | 1.3.6.1.4.1.4253.1.26.2.1.21 | INTEGER | read-only | mandatory |
| voadmPortTable OBJECT-TYPE This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports. | 1.3.6.1.4.1.4253.1.26.3 | not-accessible | mandatory | |
| voadmPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.26.3.1 | not-accessible | mandatory | |
| voadmPortCardLocation OBJECT-TYPE Location of the module. VOADM modules will always be seen as local modules. | 1.3.6.1.4.1.4253.1.26.3.1.1 | CardLocation | read-only | mandatory |
| voadmPortCardShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.26.3.1.2 | CardShelf | read-only | mandatory |
| voadmPortCardSlot OBJECT-TYPE The slot within the shelf where the module resides. | 1.3.6.1.4.1.4253.1.26.3.1.3 | SlotInput | read-only | mandatory |
| voadmPortType OBJECT-TYPE Port type for which the below values apply. | 1.3.6.1.4.1.4253.1.26.3.1.4 | INTEGER {mux(1), demux(2)} | read-only | mandatory |
| voadmPortMode OBJECT-TYPE Port mode. This value will not be stored in the database until the port set point is set. | 1.3.6.1.4.1.4253.1.26.3.1.5 | INTEGER {fixed-attentuation(1), fixed-power(2)} | read-write | mandatory |
| voadmPortSetPoint OBJECT-TYPE Port set point. Valid range depends on the port mode: Fixed Attentuation 0.0 to 20.0 (dB) Fixed Power -30.0 to 15.0 (dBm) Untils are omitted when setting. | 1.3.6.1.4.1.4253.1.26.3.1.6 | DisplayString | read-write | mandatory |
| voadmPortMinChanInputPower OBJECT-TYPE Minimum input power for each active channel. Valid range for Mux and Demux ports is -30.0 to 15.0 dBm | 1.3.6.1.4.1.4253.1.26.3.1.7 | DisplayString | read-write | mandatory |
| voadmPortMinChanOutputPower OBJECT-TYPE Minimum output power for each active channel. Valid range depends on port: Mux -20.0 to 15.0 dBm Demux -30.0 to -8.0 dBm. | 1.3.6.1.4.1.4253.1.26.3.1.8 | DisplayString | read-write | mandatory |
| voadmPortMaxChanOutputPower OBJECT-TYPE Maximum output power for each active channel. Valid range depends on port: Mux -20.0 to 15.0 dBm Demux -30.0 to -8.0 dBm. | 1.3.6.1.4.1.4253.1.26.3.1.9 | DisplayString | read-write | mandatory |
| voadmPortToleranceUpperBound OBJECT-TYPE Upper bound for allowable power/attenuation error. Valid range is 0.2 to 10.0 dB. | 1.3.6.1.4.1.4253.1.26.3.1.10 | DisplayString | read-write | mandatory |
| voadmPortToleranceLowerBound OBJECT-TYPE Lower bound for allowable power/attenuation error. Valid range is 0.2 to 10.0 dB. | 1.3.6.1.4.1.4253.1.26.3.1.11 | DisplayString | read-write | mandatory |
| voadmPortTotalInputPower OBJECT-TYPE Power reading from input detector. Valid range: -30 to 15 dBm | 1.3.6.1.4.1.4253.1.26.3.1.12 | DisplayString | read-only | mandatory |
| voadmPortPerChanInputPower OBJECT-TYPE Total input power divided by number of active channels. Valid range: -30 to 15 dBm | 1.3.6.1.4.1.4253.1.26.3.1.13 | DisplayString | read-only | mandatory |
| voadmPortTotalOutputPower OBJECT-TYPE Power reading from output detector. Valid range: -30 to 15 dBm | 1.3.6.1.4.1.4253.1.26.3.1.14 | DisplayString | read-only | mandatory |
| voadmPortPerChanOutputPower OBJECT-TYPE Total output power divided by number of active channels. Valid range: -30 to 15 dBm | 1.3.6.1.4.1.4253.1.26.3.1.15 | DisplayString | read-only | mandatory |
| voadmPortMeasuredAtten OBJECT-TYPE Difference between total input power and total output power. | 1.3.6.1.4.1.4253.1.26.3.1.16 | DisplayString | read-only | mandatory |
| voadmPortAvgInsertLoss OBJECT-TYPE Average insertion loss for ports. | 1.3.6.1.4.1.4253.1.26.3.1.17 | DisplayString | read-only | mandatory |
| voadmPortAvgExpressLoss OBJECT-TYPE Average express los for ports. | 1.3.6.1.4.1.4253.1.26.3.1.18 | DisplayString | read-only | mandatory |
| zmsConfigSync OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.27 | |||
| zmsConfigSyncExists OBJECT-TYPE Indicates whether or not there exists records to be sent to the ZMS config synch manager for changes that have been made by CLI/HTTP to the data base. | 1.3.6.1.4.1.4253.1.27.1 | Boolean | read-only | current |
| zmsConfigSyncOverflow OBJECT-TYPE Indicates whether or not the device had to discard update data base records due to resource constraints. If TRUE, traps will be sent to the ZMS Config Synch Manager indicating a download of the entire data base is required. | 1.3.6.1.4.1.4253.1.27.2 | Boolean | read-only | current |
| zmsConfigSyncPriority OBJECT-TYPE Indicates the highest priority configuration synchronization trap outstanding. This flag is set to none at boot time and whenever a file of synchronization changes has been sent to ZMS. If a parameter change has been made to either the same or lower prioirty, the device does not have to send a change notification to ZMS. Higher priority fields must immediately cause traps to be sent to ZMS. | 1.3.6.1.4.1.4253.1.27.3 | INTEGER {none(1), low(2), medium(3), high(4)} | read-only | current |
| zmsConfigSyncAction OBJECT-TYPE Used by ZMS when it wants to create a list of config synch records. It must first write the filename expected and then set the action. The create list action allows the device to determine whether the complete database (synchoverflow occured) needs to be sent or only those records that have been modified. create full list specifies that ZMS would like to receive the complete database. | 1.3.6.1.4.1.4253.1.27.4 | INTEGER {noAction(1), createList(2), createFullList(3), createFullListWithAlarms(4), createAlarmsList(5)} | read-write | current |
| zmsConfigSyncFileName OBJECT-TYPE File Name to be used when creating the config synch records. | 1.3.6.1.4.1.4253.1.27.5 | ZmsFileName | read-write | current |
| zmsConfigSyncStatus OBJECT-TYPE Used by Config Sync Acgent when processing a request to create a list of config synch records. | 1.3.6.1.4.1.4253.1.27.6 | INTEGER {syncComplete(1), syncPending(2), syncError(3), syncInitializing(4)} | read-only | current |
| zmsConfigSyncUserName OBJECT-TYPE User Name to be used when sending the config synch records. When read, the last user name is returned. | 1.3.6.1.4.1.4253.1.27.7 | ZmsAdminString | read-write | current |
| zmsConfigSyncUserPassword OBJECT-TYPE Password to be used when sending the config synch records. For use in FTP authentication. When read, always returns the NULL string | 1.3.6.1.4.1.4253.1.27.8 | ZmsAdminString | read-write | current |
| zmsIpAddress OBJECT-TYPE This is the ZMS IP address for which configuration synchronization messages and any other special handling is performed. | 1.3.6.1.4.1.4253.1.27.9 | IpAddress | read-write | current |
| dmm OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.28 | |||
| dmmNumber OBJECT-TYPE Number of rows in the dmm table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.28.1 | INTEGER | read-only | mandatory |
| dmmTable OBJECT-TYPE This table represents the information for each DMM card | 1.3.6.1.4.1.4253.1.28.2 | not-accessible | mandatory | |
| dmmEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.28.2.1 | not-accessible | mandatory | |
| dmmCardLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.28.2.1.1 | CardLocation | read-only | mandatory |
| dmmCardShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.28.2.1.2 | CardShelf | read-only | mandatory |
| dmmCardSlot OBJECT-TYPE The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.28.2.1.3 | SlotInput | read-write | mandatory |
| dmmSerialNum OBJECT-TYPE Module serial number. | 1.3.6.1.4.1.4253.1.28.2.1.4 | SerialString | read-only | mandatory |
| dmmModelNum OBJECT-TYPE Module model number. | 1.3.6.1.4.1.4253.1.28.2.1.5 | DisplayString | read-only | mandatory |
| dmmHwName OBJECT-TYPE Module hardware name. | 1.3.6.1.4.1.4253.1.28.2.1.6 | DisplayString | read-only | mandatory |
| dmmHwVersionID OBJECT-TYPE Module hardware version. | 1.3.6.1.4.1.4253.1.28.2.1.7 | VersionString | read-only | mandatory |
| dmmMfgDate OBJECT-TYPE Date and Time of manufacturing of the module | 1.3.6.1.4.1.4253.1.28.2.1.8 | DateAndTime | read-only | mandatory |
| dmmFwName OBJECT-TYPE Module firmware name. | 1.3.6.1.4.1.4253.1.28.2.1.9 | CardName | read-only | mandatory |
| dmmFwVersionID OBJECT-TYPE Firmware version. | 1.3.6.1.4.1.4253.1.28.2.1.10 | VersionString | read-only | mandatory |
| dmmFwDate OBJECT-TYPE Firmware release date and time. | 1.3.6.1.4.1.4253.1.28.2.1.11 | DateAndTime | read-only | mandatory |
| dmmAdminState OBJECT-TYPE Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module. | 1.3.6.1.4.1.4253.1.28.2.1.12 | INTEGER {disable(1), enable(2), na(3)} | read-write | mandatory |
| dmmModelType OBJECT-TYPE Model type of the module. | 1.3.6.1.4.1.4253.1.28.2.1.13 | CardType | read-only | mandatory |
| dmmName OBJECT-TYPE User configurable name of the module. | 1.3.6.1.4.1.4253.1.28.2.1.14 | CardName | read-write | mandatory |
| dmmSetState OBJECT-TYPE Instruct the module to do a warmboot. A get on this will always return 'other'. | 1.3.6.1.4.1.4253.1.28.2.1.15 | INTEGER {other(1), warmboot(2), enableLinkLoopback(3), enablePort1Loopback(4), enablePort2Loopback(5), disableloopback(6)} | read-write | mandatory |
| dmmPathID OBJECT-TYPE Path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path. | 1.3.6.1.4.1.4253.1.28.2.1.16 | PathIdName | read-write | mandatory |
| dmmLinkName OBJECT-TYPE Link name for fiber between the local and the remote card. | 1.3.6.1.4.1.4253.1.28.2.1.17 | LinkName | read-write | mandatory |
| dmmCleiNum OBJECT-TYPE CLEI number of the module. | 1.3.6.1.4.1.4253.1.28.2.1.18 | DisplayString | read-only | mandatory |
| dmmNumPorts OBJECT-TYPE Total port numbers on each DMM card. | 1.3.6.1.4.1.4253.1.28.2.1.19 | INTEGER | read-only | mandatory |
| dmmFpgaRev OBJECT-TYPE FPGA revision for the module. | 1.3.6.1.4.1.4253.1.28.2.1.20 | INTEGER | read-only | mandatory |
| dmmPortTable OBJECT-TYPE This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports. | 1.3.6.1.4.1.4253.1.28.3 | not-accessible | mandatory | |
| dmmPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.28.3.1 | not-accessible | mandatory | |
| dmmPortLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.28.3.1.1 | CardLocation | read-only | mandatory |
| dmmPortShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.28.3.1.2 | CardShelf | read-only | mandatory |
| dmmPortSlot OBJECT-TYPE The slot within the shelf where the module resides. | 1.3.6.1.4.1.4253.1.28.3.1.3 | SlotInput | read-only | mandatory |
| dmmPortIndex OBJECT-TYPE Port for which the below values apply. | 1.3.6.1.4.1.4253.1.28.3.1.4 | INTEGER {link(1), port1(2), port2(3)} | read-only | mandatory |
| dmmPortLineRate OBJECT-TYPE Port line rate. Valid only for ports 1 and 2. | 1.3.6.1.4.1.4253.1.28.3.1.5 | INTEGER {notapplicable(0), gbEthernet(4), fibreChannel(5), disabled(255)} | read-write | mandatory |
| dmmPortAutoDisable OBJECT-TYPE Flag to enable/disable the CPE link when a fault is detected. Far end CPE disable is identical to normal CPE disable with the added feature that the local CPE Tx will be disabled if a loss of light condition is detected on the remote CPE Rx. | 1.3.6.1.4.1.4253.1.28.3.1.6 | INTEGER {notapplicable(0), enable(1), disable(2), farEndEnable(3)} | read-write | mandatory |
| dmmPortMode OBJECT-TYPE Port mode. | 1.3.6.1.4.1.4253.1.28.3.1.7 | INTEGER {disabled(1), enabled(2), loopback(3)} | read-only | mandatory |
| dmmPortItu OBJECT-TYPE Port ITU number. The ITU number is determined from the SFP wavelength. | 1.3.6.1.4.1.4253.1.28.3.1.8 | INTEGER | read-only | mandatory |
| dmmPortWavelength OBJECT-TYPE Wavelength from port SFP. | 1.3.6.1.4.1.4253.1.28.3.1.9 | DisplayString | read-only | mandatory |
| dmmPortRxPower OBJECT-TYPE Receive power reported by port SFP. | 1.3.6.1.4.1.4253.1.28.3.1.10 | DisplayString | read-only | mandatory |
| dmmPortTxState OBJECT-TYPE State of port SFP transmitter. | 1.3.6.1.4.1.4253.1.28.3.1.11 | INTEGER {on(1), off(2)} | read-only | mandatory |
| dmmPortTxReach OBJECT-TYPE Optical reach in meters reported by port SFP. | 1.3.6.1.4.1.4253.1.28.3.1.12 | INTEGER | read-only | mandatory |
| dmmPortSfpSerialNumber OBJECT-TYPE Port SFP serial number. | 1.3.6.1.4.1.4253.1.28.3.1.13 | DisplayString | read-only | mandatory |
| dmmPortSfpConnectorType OBJECT-TYPE Port SFP connector type. | 1.3.6.1.4.1.4253.1.28.3.1.14 | INTEGER {na(0), unknown(1), sc(2), fc_copper1(3), fc_capper2(4), bnc(5), fc_coaxial(6), fiberjack(7), lc(8), mtrj(9), mu(10), sg(11), optpigtail(12), hssdcii(33), copper(34)} | read-only | mandatory |
| dmmConnTable OBJECT-TYPE This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports. | 1.3.6.1.4.1.4253.1.28.4 | not-accessible | mandatory | |
| dmmConnEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.28.4.1 | not-accessible | mandatory | |
| dmmConnCardLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.28.4.1.1 | CardLocation | read-only | mandatory |
| dmmConnCardShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.28.4.1.2 | CardShelf | read-only | mandatory |
| dmmConnCardSlot OBJECT-TYPE The slot within the shelf where the module resides. | 1.3.6.1.4.1.4253.1.28.4.1.3 | SlotInput | read-only | mandatory |
| dmmConnCardPortType OBJECT-TYPE Port for which the below values apply. | 1.3.6.1.4.1.4253.1.28.4.1.4 | INTEGER {port1tx(1), port1rx(2), port2tx(3), port2rx(4), linktx(5), linkrx(6)} | read-only | mandatory |
| dmmConnCardType OBJECT-TYPE Module type connected to port. | 1.3.6.1.4.1.4253.1.28.4.1.5 | CardType | read-only | mandatory |
| dmmConnLocation OBJECT-TYPE The chassis location of the card connected to this port. | 1.3.6.1.4.1.4253.1.28.4.1.6 | CardLocation | read-only | mandatory |
| dmmConnShelf OBJECT-TYPE The shelf of the card connected to this port | 1.3.6.1.4.1.4253.1.28.4.1.7 | ShelfInput | read-only | mandatory |
| dmmConnSlot OBJECT-TYPE The slot of the card connected to this port | 1.3.6.1.4.1.4253.1.28.4.1.8 | SlotInput | read-only | mandatory |
| dmmConnPort OBJECT-TYPE Conn port for the DMM's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. Entry supported by all Mux modules except MD100-40 & BD4. | 1.3.6.1.4.1.4253.1.28.4.1.9 | INTEGER | read-only | mandatory |
| ocm10gf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.29 | |||
| ocm10gfNumber OBJECT-TYPE Number of rows in the ocm10gf table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.29.1 | INTEGER | read-only | mandatory |
| ocm10gfTable OBJECT-TYPE This table represents the information for each OCM10GF card | 1.3.6.1.4.1.4253.1.29.2 | not-accessible | mandatory | |
| ocm10gfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.29.2.1 | not-accessible | mandatory | |
| ocm10gfCardLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.29.2.1.1 | CardLocation | read-only | mandatory |
| ocm10gfCardShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.29.2.1.2 | CardShelf | read-only | mandatory |
| ocm10gfCardSlot OBJECT-TYPE The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.29.2.1.3 | SlotInput | read-write | mandatory |
| ocm10gfSerialNum OBJECT-TYPE Module serial number. | 1.3.6.1.4.1.4253.1.29.2.1.4 | SerialString | read-only | mandatory |
| ocm10gfModelNum OBJECT-TYPE Module model number. | 1.3.6.1.4.1.4253.1.29.2.1.5 | DisplayString | read-only | mandatory |
| ocm10gfHwName OBJECT-TYPE Module hardware name. | 1.3.6.1.4.1.4253.1.29.2.1.6 | DisplayString | read-only | mandatory |
| ocm10gfHwVersionID OBJECT-TYPE Module hardware version. | 1.3.6.1.4.1.4253.1.29.2.1.7 | VersionString | read-only | mandatory |
| ocm10gfMfgDate OBJECT-TYPE Date and Time of manufacturing of the module | 1.3.6.1.4.1.4253.1.29.2.1.8 | DateAndTime | read-only | mandatory |
| ocm10gfFwName OBJECT-TYPE Module firmware name. | 1.3.6.1.4.1.4253.1.29.2.1.9 | CardName | read-only | mandatory |
| ocm10gfFwVersionID OBJECT-TYPE Firmware version. | 1.3.6.1.4.1.4253.1.29.2.1.10 | VersionString | read-only | mandatory |
| ocm10gfFwDate OBJECT-TYPE Firmware release date and time. | 1.3.6.1.4.1.4253.1.29.2.1.11 | DateAndTime | read-only | mandatory |
| ocm10gfModelType OBJECT-TYPE Model type of the module. | 1.3.6.1.4.1.4253.1.29.2.1.12 | CardType | read-only | mandatory |
| ocm10gfName OBJECT-TYPE User configurable name of the module. | 1.3.6.1.4.1.4253.1.29.2.1.13 | CardName | read-write | mandatory |
| ocm10gfLineRate OBJECT-TYPE Port line rate. Valid only for ports 1 and 2. | 1.3.6.1.4.1.4253.1.29.2.1.14 | INTEGER {gbE10(9), fc10(11), oc192nt(12), oc192tr(13), disabled(255)} | read-write | mandatory |
| ocm10gfAutoDisable OBJECT-TYPE Flag to enable/disable the CPE link when a fault is detected. Far end CPE disable is identical to normal CPE disable with the added feature that the local CPE Tx will be disabled if a loss of light condition is detected on the remote CPE Rx. | 1.3.6.1.4.1.4253.1.29.2.1.15 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| ocm10gfLinkName OBJECT-TYPE Link name for fiber between the local and the remote card. | 1.3.6.1.4.1.4253.1.29.2.1.16 | LinkName | read-write | mandatory |
| ocm10gfPathID OBJECT-TYPE Path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path. | 1.3.6.1.4.1.4253.1.29.2.1.17 | PathIdName | read-write | mandatory |
| ocm10gfAdminState OBJECT-TYPE Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module. | 1.3.6.1.4.1.4253.1.29.2.1.18 | INTEGER {disable(1), enable(2), na(3)} | read-write | mandatory |
| ocm10gfSetState OBJECT-TYPE Instruct the module to do a warmboot. A get on this will always return 'other'. | 1.3.6.1.4.1.4253.1.29.2.1.19 | INTEGER {other(1), warmboot(2), enableLinkLoopback(3), enableCpeLoopback(4), disableloopback(5)} | read-write | mandatory |
| ocm10gfCleiNum OBJECT-TYPE CLEI number of the module. | 1.3.6.1.4.1.4253.1.29.2.1.20 | DisplayString | read-only | mandatory |
| ocm10gfNumPorts OBJECT-TYPE Total port numbers on each OCM10GF card. | 1.3.6.1.4.1.4253.1.29.2.1.21 | INTEGER | read-only | mandatory |
| ocm10gfFpgaRev OBJECT-TYPE FPGA revision for the module. | 1.3.6.1.4.1.4253.1.29.2.1.22 | INTEGER | read-only | mandatory |
| ocm10gfPortTable OBJECT-TYPE This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports. | 1.3.6.1.4.1.4253.1.29.3 | not-accessible | mandatory | |
| ocm10gfPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.29.3.1 | not-accessible | mandatory | |
| ocm10gfPortLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.29.3.1.1 | CardLocation | read-only | mandatory |
| ocm10gfPortShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.29.3.1.2 | CardShelf | read-only | mandatory |
| ocm10gfPortSlot OBJECT-TYPE The slot within the shelf where the module resides. | 1.3.6.1.4.1.4253.1.29.3.1.3 | SlotInput | read-only | mandatory |
| ocm10gfPortIndex OBJECT-TYPE Port for which the below values apply. | 1.3.6.1.4.1.4253.1.29.3.1.4 | INTEGER {link(1), cpe(2)} | read-only | mandatory |
| ocm10gfPortMode OBJECT-TYPE Port mode. | 1.3.6.1.4.1.4253.1.29.3.1.5 | INTEGER {disabled(1), enabled(2), loopback(3)} | read-only | mandatory |
| ocm10gfPortWavelength OBJECT-TYPE Wavelength from port SFP. | 1.3.6.1.4.1.4253.1.29.3.1.6 | DisplayString | read-only | mandatory |
| ocm10gfPortRxPower OBJECT-TYPE Receive power reported by port SFP. | 1.3.6.1.4.1.4253.1.29.3.1.7 | DisplayString | read-only | mandatory |
| ocm10gfPortTxState OBJECT-TYPE State of port SFP transmitter. | 1.3.6.1.4.1.4253.1.29.3.1.8 | INTEGER {na(0), on(1), off(2)} | read-only | mandatory |
| ocm10gfPortTxReach OBJECT-TYPE Optical reach in meters reported by port SFP. | 1.3.6.1.4.1.4253.1.29.3.1.9 | INTEGER | read-only | mandatory |
| ocm10gfPortXfpSerialNumber OBJECT-TYPE Port SFP serial number. | 1.3.6.1.4.1.4253.1.29.3.1.10 | DisplayString | read-only | mandatory |
| ocm10gfConnTable OBJECT-TYPE This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports. | 1.3.6.1.4.1.4253.1.29.4 | not-accessible | mandatory | |
| ocm10gfConnEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.29.4.1 | not-accessible | mandatory | |
| ocm10gfConnCardLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.29.4.1.1 | CardLocation | read-only | mandatory |
| ocm10gfConnCardShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.29.4.1.2 | CardShelf | read-only | mandatory |
| ocm10gfConnCardSlot OBJECT-TYPE The slot within the shelf where the module resides. | 1.3.6.1.4.1.4253.1.29.4.1.3 | SlotInput | read-only | mandatory |
| ocm10gfConnCardPortType OBJECT-TYPE Port for which the below values apply. | 1.3.6.1.4.1.4253.1.29.4.1.4 | INTEGER {linktx(1), linkrx(2), cpetx(3), cperx(4)} | read-only | mandatory |
| ocm10gfConnCardType OBJECT-TYPE Module type connected to port. | 1.3.6.1.4.1.4253.1.29.4.1.5 | CardType | read-only | mandatory |
| ocm10gfConnLocation OBJECT-TYPE The chassis location of the card connected to this port. | 1.3.6.1.4.1.4253.1.29.4.1.6 | CardLocation | read-only | mandatory |
| ocm10gfConnShelf OBJECT-TYPE The shelf of the card connected to this port | 1.3.6.1.4.1.4253.1.29.4.1.7 | ShelfInput | read-only | mandatory |
| ocm10gfConnSlot OBJECT-TYPE The slot of the card connected to this port | 1.3.6.1.4.1.4253.1.29.4.1.8 | SlotInput | read-only | mandatory |
| ocm10gfConnPort OBJECT-TYPE Conn port for the OCM10GF's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. Entry supported by all Mux modules except MD100-40 & BD4. | 1.3.6.1.4.1.4253.1.29.4.1.9 | INTEGER | read-only | mandatory |
| ocm2 OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.30 | |||
| ocm2Number OBJECT-TYPE Number of rows in the ocm2 table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.30.1 | INTEGER | read-only | mandatory |
| ocm2Table OBJECT-TYPE This table represents the information for each OCM2 card | 1.3.6.1.4.1.4253.1.30.2 | not-accessible | mandatory | |
| ocm2Entry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.30.2.1 | not-accessible | mandatory | |
| ocm2CardLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.30.2.1.1 | CardLocation | read-only | mandatory |
| ocm2CardShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.30.2.1.2 | CardShelf | read-only | mandatory |
| ocm2CardSlot OBJECT-TYPE The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.30.2.1.3 | SlotInput | read-write | mandatory |
| ocm2SerialNum OBJECT-TYPE Module serial number. | 1.3.6.1.4.1.4253.1.30.2.1.4 | SerialString | read-only | mandatory |
| ocm2ModelNum OBJECT-TYPE Module model number. | 1.3.6.1.4.1.4253.1.30.2.1.5 | DisplayString | read-only | mandatory |
| ocm2HwName OBJECT-TYPE Module hardware name. | 1.3.6.1.4.1.4253.1.30.2.1.6 | DisplayString | read-only | mandatory |
| ocm2HwVersionID OBJECT-TYPE Module hardware version. | 1.3.6.1.4.1.4253.1.30.2.1.7 | VersionString | read-only | mandatory |
| ocm2MfgDate OBJECT-TYPE Date and Time of manufacturing of the module | 1.3.6.1.4.1.4253.1.30.2.1.8 | DateAndTime | read-only | mandatory |
| ocm2FwName OBJECT-TYPE Module firmware name. | 1.3.6.1.4.1.4253.1.30.2.1.9 | CardName | read-only | mandatory |
| ocm2FwVersionID OBJECT-TYPE Firmware version. | 1.3.6.1.4.1.4253.1.30.2.1.10 | VersionString | read-only | mandatory |
| ocm2FwDate OBJECT-TYPE Firmware release date and time. | 1.3.6.1.4.1.4253.1.30.2.1.11 | DateAndTime | read-only | mandatory |
| ocm2ModelType OBJECT-TYPE Model type of the module. | 1.3.6.1.4.1.4253.1.30.2.1.12 | CardType | read-only | mandatory |
| ocm2Name OBJECT-TYPE User configurable name of the module. | 1.3.6.1.4.1.4253.1.30.2.1.13 | CardName | read-write | mandatory |
| ocm2Link1LineRate OBJECT-TYPE Link 1 line rate. | 1.3.6.1.4.1.4253.1.30.2.1.14 | INTEGER {na(0), oc3(1), oc12(2), oc48(3), gbe(4), fc(5), escon(8), fc2(10), hlf_fc(14), infiniband(15), disabled(255)} | read-write | mandatory |
| ocm2Link1AutoDisable OBJECT-TYPE Flag to enable/disable automatic CPE disable for Link 1. | 1.3.6.1.4.1.4253.1.30.2.1.15 | INTEGER {na(0), enable(1), disable(2)} | read-write | mandatory |
| ocm2Link1LinkName OBJECT-TYPE Link 1 link name for fiber between the local and the remote card. | 1.3.6.1.4.1.4253.1.30.2.1.16 | LinkName | read-write | mandatory |
| ocm2Link1PathID OBJECT-TYPE Link 1 path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path. | 1.3.6.1.4.1.4253.1.30.2.1.17 | PathIdName | read-write | mandatory |
| ocm2Link2LineRate OBJECT-TYPE Link 2 line rate. | 1.3.6.1.4.1.4253.1.30.2.1.18 | INTEGER {na(0), oc3(1), oc12(2), oc48(3), gbe(4), fc(5), escon(8), fc2(10), hlf_fc(14), infiniband(15), disabled(255)} | read-write | mandatory |
| ocm2Link2AutoDisable OBJECT-TYPE Flag to enable/disable automatic CPE disable for Link 2. | 1.3.6.1.4.1.4253.1.30.2.1.19 | INTEGER {na(0), enable(1), disable(2)} | read-write | mandatory |
| ocm2Link2LinkName OBJECT-TYPE Link 2 link name for fiber between the local and the remote card. | 1.3.6.1.4.1.4253.1.30.2.1.20 | LinkName | read-write | mandatory |
| ocm2Link2PathID OBJECT-TYPE Link 2 path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path. | 1.3.6.1.4.1.4253.1.30.2.1.21 | PathIdName | read-write | mandatory |
| ocm2AdminState OBJECT-TYPE Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module. | 1.3.6.1.4.1.4253.1.30.2.1.22 | INTEGER {disable(1), enable(2), na(3)} | read-write | mandatory |
| ocm2SetState OBJECT-TYPE Instruct the module to do a warmboot. A get on this will always return 'other'. | 1.3.6.1.4.1.4253.1.30.2.1.23 | INTEGER {other(1), warmboot(2), enableLink1Loopback(3), enableLink2Loopback(4), disableLink1loopback(5), disableLink2loopback(6)} | read-write | mandatory |
| ocm2CleiNum OBJECT-TYPE CLEI number of the module. | 1.3.6.1.4.1.4253.1.30.2.1.24 | DisplayString | read-only | mandatory |
| ocm2NumPorts OBJECT-TYPE Total port numbers on each OCM2 card. | 1.3.6.1.4.1.4253.1.30.2.1.25 | INTEGER | read-only | mandatory |
| ocm2RegenMode OBJECT-TYPE Set or clear OCM2 regen mode. | 1.3.6.1.4.1.4253.1.30.2.1.26 | INTEGER {enabled(1), disabled(2)} | read-write | mandatory |
| ocm2FpgaRev OBJECT-TYPE FPGA revision for the module. | 1.3.6.1.4.1.4253.1.30.2.1.27 | INTEGER | read-only | mandatory |
| ocm2PortTable OBJECT-TYPE This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports. | 1.3.6.1.4.1.4253.1.30.3 | not-accessible | mandatory | |
| ocm2PortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.30.3.1 | not-accessible | mandatory | |
| ocm2PortLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.30.3.1.1 | CardLocation | read-only | mandatory |
| ocm2PortShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.30.3.1.2 | CardShelf | read-only | mandatory |
| ocm2PortSlot OBJECT-TYPE The slot within the shelf where the module resides. | 1.3.6.1.4.1.4253.1.30.3.1.3 | SlotInput | read-only | mandatory |
| ocm2PortIndex OBJECT-TYPE Port for which the below values apply. | 1.3.6.1.4.1.4253.1.30.3.1.4 | INTEGER {link1(1), cpe1(2), link2(3), cpe2(4)} | read-only | mandatory |
| ocm2PortMode OBJECT-TYPE Port mode. | 1.3.6.1.4.1.4253.1.30.3.1.5 | INTEGER {na(0), disabled(1), enabled(2), loopback(3)} | read-only | mandatory |
| ocm2PortItu OBJECT-TYPE Port ITU number. The ITU number is determined from the SFP wavelength. | 1.3.6.1.4.1.4253.1.30.3.1.6 | INTEGER | read-only | mandatory |
| ocm2PortWavelength OBJECT-TYPE Wavelength from port SFP. | 1.3.6.1.4.1.4253.1.30.3.1.7 | DisplayString | read-only | mandatory |
| ocm2PortRxPower OBJECT-TYPE Receive power reported by port SFP. | 1.3.6.1.4.1.4253.1.30.3.1.8 | DisplayString | read-only | mandatory |
| ocm2PortTxState OBJECT-TYPE State of port SFP transmitter. | 1.3.6.1.4.1.4253.1.30.3.1.9 | INTEGER {na(0), on(1), off(2)} | read-only | mandatory |
| ocm2PortTxReach OBJECT-TYPE Optical reach in meters reported by port SFP. | 1.3.6.1.4.1.4253.1.30.3.1.10 | INTEGER | read-only | mandatory |
| ocm2PortSfpSerialNumber OBJECT-TYPE Port SFP serial number. | 1.3.6.1.4.1.4253.1.30.3.1.11 | DisplayString | read-only | mandatory |
| ocm2ConnTable OBJECT-TYPE This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports. | 1.3.6.1.4.1.4253.1.30.4 | not-accessible | mandatory | |
| ocm2ConnEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.30.4.1 | not-accessible | mandatory | |
| ocm2ConnCardLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.30.4.1.1 | CardLocation | read-only | mandatory |
| ocm2ConnCardShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.30.4.1.2 | CardShelf | read-only | mandatory |
| ocm2ConnCardSlot OBJECT-TYPE The slot within the shelf where the module resides. | 1.3.6.1.4.1.4253.1.30.4.1.3 | SlotInput | read-only | mandatory |
| ocm2ConnCardPortType OBJECT-TYPE Port for which the below values apply. | 1.3.6.1.4.1.4253.1.30.4.1.4 | INTEGER {link1tx(1), link1rx(2), link2tx(3), link2rx(4), cpe1tx(5), cpe1rx(6), cpe2tx(7), cpe2rx(8)} | read-only | mandatory |
| ocm2ConnCardType OBJECT-TYPE Module type connected to port. | 1.3.6.1.4.1.4253.1.30.4.1.5 | CardType | read-only | mandatory |
| ocm2ConnLocation OBJECT-TYPE The chassis location of the card connected to this port. | 1.3.6.1.4.1.4253.1.30.4.1.6 | CardLocation | read-only | mandatory |
| ocm2ConnShelf OBJECT-TYPE The shelf of the card connected to this port | 1.3.6.1.4.1.4253.1.30.4.1.7 | ShelfInput | read-only | mandatory |
| ocm2ConnSlot OBJECT-TYPE The slot of the card connected to this port | 1.3.6.1.4.1.4253.1.30.4.1.8 | SlotInput | read-only | mandatory |
| ocm2ConnPort OBJECT-TYPE Conn port for the OCM2's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. Entry supported by all Mux modules except MD100-40 & BD4. | 1.3.6.1.4.1.4253.1.30.4.1.9 | INTEGER | read-only | mandatory |
| osc OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.31 | |||
| oscNumber OBJECT-TYPE Number of rows in the osc table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.31.1 | INTEGER | read-only | mandatory |
| oscTable OBJECT-TYPE This table represents the information for each OSC card | 1.3.6.1.4.1.4253.1.31.2 | not-accessible | mandatory | |
| oscEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.31.2.1 | not-accessible | mandatory | |
| oscCardLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.31.2.1.1 | CardLocation | read-only | mandatory |
| oscCardShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.31.2.1.2 | CardShelf | read-only | mandatory |
| oscCardSlot OBJECT-TYPE The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.31.2.1.3 | SlotInput | read-write | mandatory |
| oscSerialNum OBJECT-TYPE Module serial number. | 1.3.6.1.4.1.4253.1.31.2.1.4 | SerialString | read-only | mandatory |
| oscModelNum OBJECT-TYPE Module model number. | 1.3.6.1.4.1.4253.1.31.2.1.5 | DisplayString | read-only | mandatory |
| oscHwName OBJECT-TYPE Module hardware name. | 1.3.6.1.4.1.4253.1.31.2.1.6 | DisplayString | read-only | mandatory |
| oscHwVersionID OBJECT-TYPE Module hardware version. | 1.3.6.1.4.1.4253.1.31.2.1.7 | VersionString | read-only | mandatory |
| oscMfgDate OBJECT-TYPE Date and Time of manufacturing of the module | 1.3.6.1.4.1.4253.1.31.2.1.8 | DateAndTime | read-only | mandatory |
| oscFwName OBJECT-TYPE Module firmware name. | 1.3.6.1.4.1.4253.1.31.2.1.9 | CardName | read-only | mandatory |
| oscFwVersionID OBJECT-TYPE Firmware version. | 1.3.6.1.4.1.4253.1.31.2.1.10 | VersionString | read-only | mandatory |
| oscFwDate OBJECT-TYPE Firmware release date and time. | 1.3.6.1.4.1.4253.1.31.2.1.11 | DateAndTime | read-only | mandatory |
| oscAdminState OBJECT-TYPE Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module. | 1.3.6.1.4.1.4253.1.31.2.1.12 | INTEGER {disable(1), enable(2), na(3)} | read-write | mandatory |
| oscModelType OBJECT-TYPE Model type of the module. | 1.3.6.1.4.1.4253.1.31.2.1.13 | CardType | read-only | mandatory |
| oscName OBJECT-TYPE User configurable name of the module. | 1.3.6.1.4.1.4253.1.31.2.1.14 | CardName | read-write | mandatory |
| oscPathID OBJECT-TYPE Path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path. | 1.3.6.1.4.1.4253.1.31.2.1.15 | PathIdName | read-write | mandatory |
| oscSetState OBJECT-TYPE Instruct the module to do a warmboot. A get on this will always return 'other'. | 1.3.6.1.4.1.4253.1.31.2.1.16 | INTEGER {other(1), warmboot(2)} | read-write | mandatory |
| oscCleiNum OBJECT-TYPE CLEI number of the module. | 1.3.6.1.4.1.4253.1.31.2.1.17 | DisplayString | read-only | mandatory |
| oscNumPorts OBJECT-TYPE Total port numbers on each OSC card. | 1.3.6.1.4.1.4253.1.31.2.1.18 | INTEGER | read-only | mandatory |
| oscFpgaRev OBJECT-TYPE FPGA revision for the module. | 1.3.6.1.4.1.4253.1.31.2.1.19 | INTEGER | read-only | mandatory |
| oscPortTable OBJECT-TYPE This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports. | 1.3.6.1.4.1.4253.1.31.3 | not-accessible | mandatory | |
| oscPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.31.3.1 | not-accessible | mandatory | |
| oscPortLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.31.3.1.1 | CardLocation | read-only | mandatory |
| oscPortShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.31.3.1.2 | CardShelf | read-only | mandatory |
| oscPortSlot OBJECT-TYPE The slot within the shelf where the module resides. | 1.3.6.1.4.1.4253.1.31.3.1.3 | SlotInput | read-only | mandatory |
| oscPortIndex OBJECT-TYPE Port for which the below values apply. | 1.3.6.1.4.1.4253.1.31.3.1.4 | INTEGER {link(1)} | read-only | mandatory |
| oscPortItu OBJECT-TYPE Port ITU number. The ITU number is determined from the SFP wavelength. | 1.3.6.1.4.1.4253.1.31.3.1.5 | INTEGER | read-only | mandatory |
| oscPortWavelength OBJECT-TYPE Wavelength from port SFP. | 1.3.6.1.4.1.4253.1.31.3.1.6 | DisplayString | read-only | mandatory |
| oscPortRxPower OBJECT-TYPE Receive power reported by port SFP. | 1.3.6.1.4.1.4253.1.31.3.1.7 | DisplayString | read-only | mandatory |
| oscPortTxState OBJECT-TYPE State of port SFP transmitter. | 1.3.6.1.4.1.4253.1.31.3.1.8 | INTEGER {na(0), on(1), off(2)} | read-only | mandatory |
| oscPortTxReach OBJECT-TYPE Optical reach in meters reported by port SFP. | 1.3.6.1.4.1.4253.1.31.3.1.9 | INTEGER | read-only | mandatory |
| oscPortSfpSerialNumber OBJECT-TYPE Port SFP serial number. | 1.3.6.1.4.1.4253.1.31.3.1.10 | DisplayString | read-only | mandatory |
| ocm4g OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.32 | |||
| ocm4gNumber OBJECT-TYPE Number of rows in the ocm4g table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.32.1 | INTEGER | read-only | mandatory |
| ocm4gTable OBJECT-TYPE This table represents the information for each OCM4G card | 1.3.6.1.4.1.4253.1.32.2 | not-accessible | mandatory | |
| ocm4gEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.32.2.1 | not-accessible | mandatory | |
| ocm4gCardLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.32.2.1.1 | INTEGER {local(1)} | read-only | mandatory |
| ocm4gCardShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.32.2.1.2 | CardShelf | read-only | mandatory |
| ocm4gCardSlot OBJECT-TYPE The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.32.2.1.3 | SlotInput | read-write | mandatory |
| ocm4gSerialNum OBJECT-TYPE Module serial number. | 1.3.6.1.4.1.4253.1.32.2.1.4 | SerialString | read-only | mandatory |
| ocm4gModelNum OBJECT-TYPE Module model number. | 1.3.6.1.4.1.4253.1.32.2.1.5 | DisplayString | read-only | mandatory |
| ocm4gHwName OBJECT-TYPE Module hardware name. | 1.3.6.1.4.1.4253.1.32.2.1.6 | DisplayString | read-only | mandatory |
| ocm4gHwVersionID OBJECT-TYPE Module hardware version. | 1.3.6.1.4.1.4253.1.32.2.1.7 | VersionString | read-only | mandatory |
| ocm4gMfgDate OBJECT-TYPE Date and Time of manufacturing of the module | 1.3.6.1.4.1.4253.1.32.2.1.8 | DateAndTime | read-only | mandatory |
| ocm4gFwName OBJECT-TYPE Module firmware name. | 1.3.6.1.4.1.4253.1.32.2.1.9 | CardName | read-only | mandatory |
| ocm4gFwVersionID OBJECT-TYPE Firmware version. | 1.3.6.1.4.1.4253.1.32.2.1.10 | VersionString | read-only | mandatory |
| ocm4gFwDate OBJECT-TYPE Firmware release date and time. | 1.3.6.1.4.1.4253.1.32.2.1.11 | DateAndTime | read-only | mandatory |
| ocm4gModelType OBJECT-TYPE Model type of the module. | 1.3.6.1.4.1.4253.1.32.2.1.12 | CardType | read-only | mandatory |
| ocm4gName OBJECT-TYPE User configurable name of the module. | 1.3.6.1.4.1.4253.1.32.2.1.13 | CardName | read-write | mandatory |
| ocm4gLink1LineRate OBJECT-TYPE Link 1 line rate. | 1.3.6.1.4.1.4253.1.32.2.1.14 | INTEGER {na(0), oc3(1), oc12(2), oc48(3), gbe(4), fc(5), escon(8), fc2(10), hlf_fc(14), infiniband(15), fourG(16), twoR(17), disabled(255)} | read-write | mandatory |
| ocm4gLink1AutoDisable OBJECT-TYPE Flag to enable/disable automatic CPE disable for Link 1. | 1.3.6.1.4.1.4253.1.32.2.1.15 | INTEGER {na(0), enable(1), disable(2)} | read-write | mandatory |
| ocm4gLink1LinkName OBJECT-TYPE Link 1 link name for fiber between the local and the remote card. | 1.3.6.1.4.1.4253.1.32.2.1.16 | LinkName | read-write | mandatory |
| ocm4gLink1PathID OBJECT-TYPE Link 1 path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path. | 1.3.6.1.4.1.4253.1.32.2.1.17 | PathIdName | read-write | mandatory |
| ocm4gLink2LineRate OBJECT-TYPE Link 2 line rate. | 1.3.6.1.4.1.4253.1.32.2.1.18 | INTEGER {na(0), oc3(1), oc12(2), oc48(3), gbe(4), fc(5), escon(8), fc2(10), hlf_fc(14), infiniband(15), fourG(16), twoR(17), disabled(255)} | read-write | mandatory |
| ocm4gLink2AutoDisable OBJECT-TYPE Flag to enable/disable automatic CPE disable for Link 2. | 1.3.6.1.4.1.4253.1.32.2.1.19 | INTEGER {na(0), enable(1), disable(2)} | read-write | mandatory |
| ocm4gLink2LinkName OBJECT-TYPE Link 2 link name for fiber between the local and the remote card. | 1.3.6.1.4.1.4253.1.32.2.1.20 | LinkName | read-write | mandatory |
| ocm4gLink2PathID OBJECT-TYPE Link 2 path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path. | 1.3.6.1.4.1.4253.1.32.2.1.21 | PathIdName | read-write | mandatory |
| ocm4gAdminState OBJECT-TYPE Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module. | 1.3.6.1.4.1.4253.1.32.2.1.22 | INTEGER {disable(1), enable(2), na(3)} | read-write | mandatory |
| ocm4gSetState OBJECT-TYPE Instruct the module to do a warmboot. A get on this will always return 'other'. | 1.3.6.1.4.1.4253.1.32.2.1.23 | INTEGER {other(1), warmboot(2), enableLink1Loopback(3), enableLink2Loopback(4), disableLink1loopback(5), disableLink2loopback(6)} | read-write | mandatory |
| ocm4gCleiNum OBJECT-TYPE CLEI number of the module. | 1.3.6.1.4.1.4253.1.32.2.1.24 | DisplayString | read-only | mandatory |
| ocm4gNumPorts OBJECT-TYPE Total port numbers on each OCM4G card. | 1.3.6.1.4.1.4253.1.32.2.1.25 | INTEGER | read-only | mandatory |
| ocm4gFpgaRev OBJECT-TYPE FPGA revision for the module. | 1.3.6.1.4.1.4253.1.32.2.1.26 | INTEGER | read-only | mandatory |
| ocm4gPortTable OBJECT-TYPE This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports. | 1.3.6.1.4.1.4253.1.32.3 | not-accessible | mandatory | |
| ocm4gPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.32.3.1 | not-accessible | mandatory | |
| ocm4gPortLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.32.3.1.1 | INTEGER {local(1)} | read-only | mandatory |
| ocm4gPortShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.32.3.1.2 | CardShelf | read-only | mandatory |
| ocm4gPortSlot OBJECT-TYPE The slot within the shelf where the module resides. | 1.3.6.1.4.1.4253.1.32.3.1.3 | SlotInput | read-only | mandatory |
| ocm4gPortIndex OBJECT-TYPE Port for which the below values apply. | 1.3.6.1.4.1.4253.1.32.3.1.4 | INTEGER {link1(1), cpe1(2), link2(3), cpe2(4)} | read-only | mandatory |
| ocm4gPortMode OBJECT-TYPE Port mode. | 1.3.6.1.4.1.4253.1.32.3.1.5 | INTEGER {na(0), disabled(1), enabled(2), loopback(3)} | read-only | mandatory |
| ocm4gPortItu OBJECT-TYPE Port ITU number. The ITU number is determined from the SFP wavelength. | 1.3.6.1.4.1.4253.1.32.3.1.6 | INTEGER | read-only | mandatory |
| ocm4gPortWavelength OBJECT-TYPE Wavelength from port SFP. | 1.3.6.1.4.1.4253.1.32.3.1.7 | DisplayString | read-only | mandatory |
| ocm4gPortRxPower OBJECT-TYPE Receive power reported by port SFP. | 1.3.6.1.4.1.4253.1.32.3.1.8 | DisplayString | read-only | mandatory |
| ocm4gPortTxState OBJECT-TYPE State of port SFP transmitter. | 1.3.6.1.4.1.4253.1.32.3.1.9 | INTEGER {na(0), on(1), off(2)} | read-only | mandatory |
| ocm4gPortTxReach OBJECT-TYPE Optical reach in meters reported by port SFP. | 1.3.6.1.4.1.4253.1.32.3.1.10 | INTEGER | read-only | mandatory |
| ocm4gPortSfpSerialNumber OBJECT-TYPE Port SFP serial number. | 1.3.6.1.4.1.4253.1.32.3.1.11 | DisplayString | read-only | mandatory |
| ocm4gConnTable OBJECT-TYPE This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports. | 1.3.6.1.4.1.4253.1.32.4 | not-accessible | mandatory | |
| ocm4gConnEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.32.4.1 | not-accessible | mandatory | |
| ocm4gConnCardLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.32.4.1.1 | INTEGER {local(1)} | read-only | mandatory |
| ocm4gConnCardShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.32.4.1.2 | CardShelf | read-only | mandatory |
| ocm4gConnCardSlot OBJECT-TYPE The slot within the shelf where the module resides. | 1.3.6.1.4.1.4253.1.32.4.1.3 | SlotInput | read-only | mandatory |
| ocm4gConnCardPortType OBJECT-TYPE Port for which the below values apply. | 1.3.6.1.4.1.4253.1.32.4.1.4 | INTEGER {link1tx(1), link1rx(2), link2tx(3), link2rx(4), cpe1tx(5), cpe1rx(6), cpe2tx(7), cpe2rx(8)} | read-only | mandatory |
| ocm4gConnCardType OBJECT-TYPE Module type connected to port. | 1.3.6.1.4.1.4253.1.32.4.1.5 | CardType | read-only | mandatory |
| ocm4gConnLocation OBJECT-TYPE The chassis location of the card connected to this port. | 1.3.6.1.4.1.4253.1.32.4.1.6 | INTEGER {local(1)} | read-only | mandatory |
| ocm4gConnShelf OBJECT-TYPE The shelf of the card connected to this port | 1.3.6.1.4.1.4253.1.32.4.1.7 | ShelfInput | read-only | mandatory |
| ocm4gConnSlot OBJECT-TYPE The slot of the card connected to this port | 1.3.6.1.4.1.4253.1.32.4.1.8 | SlotInput | read-only | mandatory |
| ocm4gConnPort OBJECT-TYPE Conn port for the OCM4G's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. Entry supported by all Mux modules except MD100-40 & BD4. | 1.3.6.1.4.1.4253.1.32.4.1.9 | INTEGER | read-only | mandatory |
| oet OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.33 | |||
| oetNumber OBJECT-TYPE Number of rows in the oet table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.33.1 | INTEGER | read-only | mandatory |
| oetTable OBJECT-TYPE This table represents the information for each OET card | 1.3.6.1.4.1.4253.1.33.2 | not-accessible | mandatory | |
| oetEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.33.2.1 | not-accessible | mandatory | |
| oetCardLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.33.2.1.1 | CardLocation | read-only | mandatory |
| oetCardShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.33.2.1.2 | CardShelf | read-only | mandatory |
| oetCardSlot OBJECT-TYPE The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.33.2.1.3 | SlotInput | read-write | mandatory |
| oetSerialNum OBJECT-TYPE Module serial number. | 1.3.6.1.4.1.4253.1.33.2.1.4 | SerialString | read-only | mandatory |
| oetModelNum OBJECT-TYPE Module model number. | 1.3.6.1.4.1.4253.1.33.2.1.5 | DisplayString | read-only | mandatory |
| oetHwName OBJECT-TYPE Module hardware name. | 1.3.6.1.4.1.4253.1.33.2.1.6 | DisplayString | read-only | mandatory |
| oetHwVersionID OBJECT-TYPE Module hardware version. | 1.3.6.1.4.1.4253.1.33.2.1.7 | VersionString | read-only | mandatory |
| oetMfgDate OBJECT-TYPE Date and Time of manufacturing of the module | 1.3.6.1.4.1.4253.1.33.2.1.8 | DateAndTime | read-only | mandatory |
| oetFwName OBJECT-TYPE Module firmware name. | 1.3.6.1.4.1.4253.1.33.2.1.9 | CardName | read-only | mandatory |
| oetFwVersionID OBJECT-TYPE Firmware version. | 1.3.6.1.4.1.4253.1.33.2.1.10 | VersionString | read-only | mandatory |
| oetFwDate OBJECT-TYPE Firmware release date and time. | 1.3.6.1.4.1.4253.1.33.2.1.11 | DateAndTime | read-only | mandatory |
| oetModelType OBJECT-TYPE Model type of the module. | 1.3.6.1.4.1.4253.1.33.2.1.12 | CardType | read-only | mandatory |
| oetName OBJECT-TYPE User configurable name of the module. | 1.3.6.1.4.1.4253.1.33.2.1.13 | CardName | read-write | mandatory |
| oetCleiNum OBJECT-TYPE CLEI number of the module. | 1.3.6.1.4.1.4253.1.33.2.1.14 | DisplayString | read-only | mandatory |
| oetFpgaRevMB OBJECT-TYPE FPGA revision for the module's mother board. | 1.3.6.1.4.1.4253.1.33.2.1.15 | INTEGER | read-only | mandatory |
| oetFpgaRevDB OBJECT-TYPE FPGA revision for the module's daughter board. | 1.3.6.1.4.1.4253.1.33.2.1.16 | INTEGER | read-only | mandatory |
| oetCpldRev OBJECT-TYPE CPLD revision for the module. | 1.3.6.1.4.1.4253.1.33.2.1.17 | INTEGER | read-only | mandatory |
| oetOpMode OBJECT-TYPE Operating Mode (1=Mux Mode, 2=Switch Mode). | 1.3.6.1.4.1.4253.1.33.2.1.18 | INTEGER {mux(1), switch(2)} | read-write | mandatory |
| oetProtMode OBJECT-TYPE Mux Protection. | 1.3.6.1.4.1.4253.1.33.2.1.19 | INTEGER {on(1), off(2)} | read-write | mandatory |
| oetEAPSMode OBJECT-TYPE Ethernet Automatic Protection Switching. | 1.3.6.1.4.1.4253.1.33.2.1.20 | INTEGER {disabled(1), linearEndpoint(2), linearNode(3), ringMaster(4), ringNode(5)} | read-write | mandatory |
| oetAdminState OBJECT-TYPE Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module. | 1.3.6.1.4.1.4253.1.33.2.1.21 | INTEGER {disable(1), enable(2), na(3)} | read-write | mandatory |
| oetSetState OBJECT-TYPE Instruct the module to do a warmboot. A get on this will always return 'other'. | 1.3.6.1.4.1.4253.1.33.2.1.22 | INTEGER {other(1), warmboot(2)} | read-write | mandatory |
| oetConfigInProgress OBJECT-TYPE Configured changes are pending, Apply Changes required to finish. | 1.3.6.1.4.1.4253.1.33.2.1.23 | INTEGER {yes(1), on(2)} | read-only | mandatory |
| oetApplyChanges OBJECT-TYPE Update device with pending configuration changes. Read returns 'na'. | 1.3.6.1.4.1.4253.1.33.2.1.24 | INTEGER {clear(1), apply(2), na(3)} | read-write | mandatory |
| oetLinkTable OBJECT-TYPE This table represents the information for each of the Link ports on the module. | 1.3.6.1.4.1.4253.1.33.3 | not-accessible | mandatory | |
| oetLinkEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.33.3.1 | not-accessible | mandatory | |
| oetLinkLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.33.3.1.1 | CardLocation | read-only | mandatory |
| oetLinkShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.33.3.1.2 | CardShelf | read-only | mandatory |
| oetLinkSlot OBJECT-TYPE The slot within the shelf where the module resides. | 1.3.6.1.4.1.4253.1.33.3.1.3 | SlotInput | read-only | mandatory |
| oetLinkIndex OBJECT-TYPE Link for which the below values apply. | 1.3.6.1.4.1.4253.1.33.3.1.4 | INTEGER {linkA(11), linkB(12)} | read-only | mandatory |
| oetLinkEnable OBJECT-TYPE Enables or disables the link. | 1.3.6.1.4.1.4253.1.33.3.1.5 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| oetLinkProtocol OBJECT-TYPE Protocol. | 1.3.6.1.4.1.4253.1.33.3.1.6 | INTEGER {otu(1), lan(2)} | read-write | mandatory |
| oetLinkName OBJECT-TYPE Link name for fiber between the local and the remote card. | 1.3.6.1.4.1.4253.1.33.3.1.7 | CardName | read-write | mandatory |
| oetLinkVlanIds OBJECT-TYPE Comma List of VLAN Ids - single and ranges. | 1.3.6.1.4.1.4253.1.33.3.1.8 | DisplayString (SIZE(0..80)) | read-write | mandatory |
| oetLinkConfigInProgress OBJECT-TYPE Configured changes are pending, Apply Changes required to finish. | 1.3.6.1.4.1.4253.1.33.3.1.9 | INTEGER {yes(1), on(2)} | read-only | mandatory |
| oetLinkApplyChanges OBJECT-TYPE Update device with pending configuration changes. Read returns 'na'. | 1.3.6.1.4.1.4253.1.33.3.1.10 | INTEGER {clear(1), apply(2), na(3)} | read-write | mandatory |
| oetLinkMode OBJECT-TYPE Link mode. | 1.3.6.1.4.1.4253.1.33.3.1.11 | INTEGER {na(0), disabled(1), enabled(2), loopback(3)} | read-only | mandatory |
| oetLinkItu OBJECT-TYPE Link ITU number. The ITU number is determined from the XFP wavelength. | 1.3.6.1.4.1.4253.1.33.3.1.12 | INTEGER | read-only | mandatory |
| oetLinkWavelength OBJECT-TYPE Wavelength from Link XFP. | 1.3.6.1.4.1.4253.1.33.3.1.13 | DisplayString | read-only | mandatory |
| oetLinkRxPower OBJECT-TYPE Receive power reported by Link XFP. | 1.3.6.1.4.1.4253.1.33.3.1.14 | DisplayString | read-only | mandatory |
| oetLinkTxState OBJECT-TYPE State of Link XFP transmitter. | 1.3.6.1.4.1.4253.1.33.3.1.15 | INTEGER {na(0), on(1), off(2)} | read-only | mandatory |
| oetLinkTxReach OBJECT-TYPE Optical reach in meters reported by Link XFP. | 1.3.6.1.4.1.4253.1.33.3.1.16 | INTEGER | read-only | mandatory |
| oetLinkXfpSerialNumber OBJECT-TYPE Link XFP serial number. | 1.3.6.1.4.1.4253.1.33.3.1.17 | DisplayString | read-only | mandatory |
| oetPortTable OBJECT-TYPE This table represents the information for each of the CPE ports on the module. | 1.3.6.1.4.1.4253.1.33.4 | not-accessible | mandatory | |
| oetPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.33.4.1 | not-accessible | mandatory | |
| oetPortLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.33.4.1.1 | CardLocation | read-only | mandatory |
| oetPortShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.33.4.1.2 | CardShelf | read-only | mandatory |
| oetPortSlot OBJECT-TYPE The slot within the shelf where the module resides. | 1.3.6.1.4.1.4253.1.33.4.1.3 | SlotInput | read-only | mandatory |
| oetPortIndex OBJECT-TYPE Port for which the below values apply. | 1.3.6.1.4.1.4253.1.33.4.1.4 | INTEGER {cpe(10)} | read-only | mandatory |
| oetPortEnable OBJECT-TYPE Enables or disables the port. | 1.3.6.1.4.1.4253.1.33.4.1.5 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| oetPortALSD OBJECT-TYPE Auto Laser Shutoff | 1.3.6.1.4.1.4253.1.33.4.1.6 | INTEGER {disabled(1), local(2), remote(3)} | read-write | mandatory |
| oetPortFlowControl OBJECT-TYPE Enable or disable the port's flow control. | 1.3.6.1.4.1.4253.1.33.4.1.7 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| oetPortVlanId OBJECT-TYPE Network ID must be between 1 to 200. | 1.3.6.1.4.1.4253.1.33.4.1.8 | INTEGER (1..200) | read-write | mandatory |
| oetPortName OBJECT-TYPE Port name. | 1.3.6.1.4.1.4253.1.33.4.1.9 | CardName | read-write | mandatory |
| oetPortConfigInProgress OBJECT-TYPE Configured changes are pending, Apply Changes required to finish. | 1.3.6.1.4.1.4253.1.33.4.1.10 | INTEGER {yes(1), on(2)} | read-only | mandatory |
| oetPortApplyChanges OBJECT-TYPE Update device with pending configuration changes. Read returns 'na'. | 1.3.6.1.4.1.4253.1.33.4.1.11 | INTEGER {clear(1), apply(2), na(3)} | read-write | mandatory |
| oetPortMode OBJECT-TYPE Port mode. | 1.3.6.1.4.1.4253.1.33.4.1.12 | INTEGER {na(0), disabled(1), enabled(2), loopback(3)} | read-only | mandatory |
| oetPortItu OBJECT-TYPE Port ITU number. The ITU number is determined from the SFP wavelength. | 1.3.6.1.4.1.4253.1.33.4.1.13 | INTEGER | read-only | mandatory |
| oetPortWavelength OBJECT-TYPE Wavelength from Port SFP. | 1.3.6.1.4.1.4253.1.33.4.1.14 | DisplayString | read-only | mandatory |
| oetPortRxPower OBJECT-TYPE Receive power reported by Port SFP. | 1.3.6.1.4.1.4253.1.33.4.1.15 | DisplayString | read-only | mandatory |
| oetPortTxState OBJECT-TYPE State of Port SFP transmitter. | 1.3.6.1.4.1.4253.1.33.4.1.16 | INTEGER {na(0), on(1), off(2)} | read-only | mandatory |
| oetPortTxReach OBJECT-TYPE Optical reach in meters reported by Port SFP. | 1.3.6.1.4.1.4253.1.33.4.1.17 | INTEGER | read-only | mandatory |
| oetPortSfpSerialNumber OBJECT-TYPE Port SFP serial number. | 1.3.6.1.4.1.4253.1.33.4.1.18 | DisplayString | read-only | mandatory |
| uob OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.34 | |||
| uobNumber OBJECT-TYPE Number of rows in the uob table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.34.1 | INTEGER | read-only | mandatory |
| uobTable OBJECT-TYPE This table represents the information for each UOB card | 1.3.6.1.4.1.4253.1.34.2 | not-accessible | mandatory | |
| uobEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.34.2.1 | not-accessible | mandatory | |
| uobCardLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.34.2.1.1 | CardLocation | read-only | mandatory |
| uobCardShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.34.2.1.2 | CardShelf | read-only | mandatory |
| uobCardSlot OBJECT-TYPE The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.34.2.1.3 | SlotInput | read-write | mandatory |
| uobSerialNum OBJECT-TYPE Module serial number. | 1.3.6.1.4.1.4253.1.34.2.1.4 | SerialString | read-only | mandatory |
| uobModelNum OBJECT-TYPE Module model number. | 1.3.6.1.4.1.4253.1.34.2.1.5 | DisplayString | read-only | mandatory |
| uobHwName OBJECT-TYPE Module hardware name. | 1.3.6.1.4.1.4253.1.34.2.1.6 | DisplayString | read-only | mandatory |
| uobHwVersionID OBJECT-TYPE Module hardware version. | 1.3.6.1.4.1.4253.1.34.2.1.7 | VersionString | read-only | mandatory |
| uobMfgDate OBJECT-TYPE Date and Time of manufacturing of the module | 1.3.6.1.4.1.4253.1.34.2.1.8 | DateAndTime | read-only | mandatory |
| uobFwName OBJECT-TYPE Module firmware name. | 1.3.6.1.4.1.4253.1.34.2.1.9 | CardName | read-only | mandatory |
| uobFwVersionID OBJECT-TYPE Firmware version. | 1.3.6.1.4.1.4253.1.34.2.1.10 | VersionString | read-only | mandatory |
| uobFwDate OBJECT-TYPE Firmware release date and time. | 1.3.6.1.4.1.4253.1.34.2.1.11 | DateAndTime | read-only | mandatory |
| uobModelType OBJECT-TYPE Model type of the module. | 1.3.6.1.4.1.4253.1.34.2.1.12 | CardType | read-only | mandatory |
| uobCfgName OBJECT-TYPE User configurable name of the module. | 1.3.6.1.4.1.4253.1.34.2.1.13 | CardName | read-write | mandatory |
| uobModuleName OBJECT-TYPE name of the module. | 1.3.6.1.4.1.4253.1.34.2.1.14 | DisplayString | read-only | mandatory |
| uobAdminState OBJECT-TYPE Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module. | 1.3.6.1.4.1.4253.1.34.2.1.15 | INTEGER {disable(1), enable(2), na(3)} | read-write | mandatory |
| uobSetState OBJECT-TYPE Instruct the module to do a warmboot. A get on this will always return 'other'. | 1.3.6.1.4.1.4253.1.34.2.1.16 | INTEGER {other(1), warmboot(2)} | read-write | mandatory |
| uobCleiNum OBJECT-TYPE CLEI number of the module. | 1.3.6.1.4.1.4253.1.34.2.1.17 | DisplayString | read-only | mandatory |
| uobFpgaRev OBJECT-TYPE FPGA revision for the module. | 1.3.6.1.4.1.4253.1.34.2.1.18 | INTEGER | read-only | mandatory |
| uobOperationMode OBJECT-TYPE Invalid, Constain Power, Constant Gain, Disabled. Constain Power(1) is not valid on Fixed modules. | 1.3.6.1.4.1.4253.1.34.2.1.19 | INTEGER {invalid(0), constainPower(1), constantGain(2), disabled(3)} | read-write | mandatory |
| uobOutPower OBJECT-TYPE uobModuleName - Configured Power in dBm T17VO - range: -13.0 to 17.5 T17VR - range: -13.0 to 17.5 T20FR - range: -7.0 to 20.10 T15FR - range: -7.0 to 15.10 | 1.3.6.1.4.1.4253.1.34.2.1.20 | DisplayString | read-write | mandatory |
| uobGain OBJECT-TYPE uobModuleName - Configured Gain in dB T17VO - range: 10.0 to 20.0 T17VR - range: 10.0 to 20.0 T20FR - range: 16.0 to 28.0 default:22 T15FR - range: 16.0 to 28.0 default:22 | 1.3.6.1.4.1.4253.1.34.2.1.21 | DisplayString | read-write | mandatory |
| uobGainTilt OBJECT-TYPE uobModuleName - Configured Gain Tilt in dB T17VO - range: -2.0 to 2.0 T17VR - range: -2.0 to 2.0 | 1.3.6.1.4.1.4253.1.34.2.1.22 | DisplayString | read-write | mandatory |
| uobLosMode OBJECT-TYPE No effect, Disabled in all modes, Disabled in Power Mode only | 1.3.6.1.4.1.4253.1.34.2.1.23 | INTEGER {noEffect(1), disabledInAll(2), disabledInPower(3)} | read-write | mandatory |
| uobLosThreshold OBJECT-TYPE uobModuleName - Configured Los Threshold in dBm T17VO - range: -100.0 to 45.0 default: -31 T17VR - range: -100.0 to 45.0 default: -31 T20FR - range: -40.0 to -5.0 default: -35 T15FR - range: -40.0 to -5.0 default: -35 | 1.3.6.1.4.1.4253.1.34.2.1.24 | DisplayString | read-write | mandatory |
| uobRflThreshold OBJECT-TYPE uobModuleName - Configured Rfl Threshold in dB T17VO - range: 0.0 to 50.0 T17VR - range: -23.0 to -14.0 T20FR - range: -23.0 to -14.0 T15FR - range: -23.0 to -14.0 | 1.3.6.1.4.1.4253.1.34.2.1.25 | DisplayString | read-write | mandatory |
| fc8g OBJECT-IDENTITY | 1.3.6.1.4.1.4253.1.35 | |||
| fc8gNumber OBJECT-TYPE Number of rows in the fc8g table. This number is automatically updated whenever a new row is added to the table below. | 1.3.6.1.4.1.4253.1.35.1 | INTEGER | read-only | mandatory |
| fc8gTable OBJECT-TYPE This table represents the information for each FC8G card | 1.3.6.1.4.1.4253.1.35.2 | not-accessible | mandatory | |
| fc8gEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.35.2.1 | not-accessible | mandatory | |
| fc8gCardLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.35.2.1.1 | INTEGER {local(1)} | read-only | mandatory |
| fc8gCardShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.35.2.1.2 | CardShelf | read-only | mandatory |
| fc8gCardSlot OBJECT-TYPE The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0. | 1.3.6.1.4.1.4253.1.35.2.1.3 | SlotInput | read-write | mandatory |
| fc8gSerialNum OBJECT-TYPE Module serial number. | 1.3.6.1.4.1.4253.1.35.2.1.4 | SerialString | read-only | mandatory |
| fc8gModelNum OBJECT-TYPE Module model number. | 1.3.6.1.4.1.4253.1.35.2.1.5 | DisplayString | read-only | mandatory |
| fc8gHwName OBJECT-TYPE Module hardware name. | 1.3.6.1.4.1.4253.1.35.2.1.6 | DisplayString | read-only | mandatory |
| fc8gHwVersionID OBJECT-TYPE Module hardware version. | 1.3.6.1.4.1.4253.1.35.2.1.7 | VersionString | read-only | mandatory |
| fc8gMfgDate OBJECT-TYPE Date and Time of manufacturing of the module | 1.3.6.1.4.1.4253.1.35.2.1.8 | DateAndTime | read-only | mandatory |
| fc8gFwName OBJECT-TYPE Module firmware name. | 1.3.6.1.4.1.4253.1.35.2.1.9 | CardName | read-only | mandatory |
| fc8gFwVersionID OBJECT-TYPE Firmware version. | 1.3.6.1.4.1.4253.1.35.2.1.10 | VersionString | read-only | mandatory |
| fc8gFwDate OBJECT-TYPE Firmware release date and time. | 1.3.6.1.4.1.4253.1.35.2.1.11 | DateAndTime | read-only | mandatory |
| fc8gModelType OBJECT-TYPE Model type of the module. | 1.3.6.1.4.1.4253.1.35.2.1.12 | CardType | read-only | mandatory |
| fc8gName OBJECT-TYPE User configurable name of the module. | 1.3.6.1.4.1.4253.1.35.2.1.13 | CardName | read-write | mandatory |
| fc8gLink1DataRate OBJECT-TYPE Link 1 Data rate. | 1.3.6.1.4.1.4253.1.35.2.1.14 | INTEGER {dr8G(1), dr4G(2), dr2G(3), dr1G(4)} | read-write | mandatory |
| fc8gCpe1AutoDisable OBJECT-TYPE Flag to enable/disable automatic CPE disable for Link 1. | 1.3.6.1.4.1.4253.1.35.2.1.15 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| fc8gCpe1LaserEnabled OBJECT-TYPE Flag to enable/disable the CPE laser for Link 1. | 1.3.6.1.4.1.4253.1.35.2.1.16 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| fc8gLink1LaserEnabled OBJECT-TYPE Flag to enable/disable the LINK laser for Link 1. | 1.3.6.1.4.1.4253.1.35.2.1.17 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| fc8gLink2DataRate OBJECT-TYPE Link 2 Data rate. | 1.3.6.1.4.1.4253.1.35.2.1.18 | INTEGER {dr8G(1), dr4G(2), dr2G(3), dr1G(4)} | read-write | mandatory |
| fc8gCpe2AutoDisable OBJECT-TYPE Flag to enable/disable automatic CPE disable for Link 2. | 1.3.6.1.4.1.4253.1.35.2.1.19 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| fc8gCpe2LaserEnabled OBJECT-TYPE Flag to enable/disable the CPE laser for Link 2. | 1.3.6.1.4.1.4253.1.35.2.1.20 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| fc8gLink2LaserEnabled OBJECT-TYPE Flag to enable/disable the LINK laser for Link 2. | 1.3.6.1.4.1.4253.1.35.2.1.21 | INTEGER {enable(1), disable(2)} | read-write | mandatory |
| fc8gAdminState OBJECT-TYPE Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module. | 1.3.6.1.4.1.4253.1.35.2.1.22 | INTEGER {disable(1), enable(2)} | read-write | mandatory |
| fc8gSetState OBJECT-TYPE Instruct the module to do a warmboot or loopback. Successive loopbacks can be issued. A get on this will always return 'other'. | 1.3.6.1.4.1.4253.1.35.2.1.23 | INTEGER {other(1), warmboot(2), enableChannel1LinkLoopback(3), enableChannel1CpeLoopback(4), enableChannel2LinkLoopback(5), enableChannel2CpeLoopback(6), disableChannel1loopback(7), disableChannel2loopback(8)} | read-write | mandatory |
| fc8gPortTable OBJECT-TYPE This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports. | 1.3.6.1.4.1.4253.1.35.3 | not-accessible | mandatory | |
| fc8gPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.1.35.3.1 | not-accessible | mandatory | |
| fc8gPortLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.1.35.3.1.1 | CardLocation | read-only | mandatory |
| fc8gPortShelf OBJECT-TYPE The shelf where the module resides. | 1.3.6.1.4.1.4253.1.35.3.1.2 | CardShelf | read-only | mandatory |
| fc8gPortSlot OBJECT-TYPE The slot within the shelf where the module resides. | 1.3.6.1.4.1.4253.1.35.3.1.3 | SlotInput | read-only | mandatory |
| fc8gPortIndex OBJECT-TYPE Port for which the below values apply. | 1.3.6.1.4.1.4253.1.35.3.1.4 | INTEGER {link1(1), cpe1(2), link2(3), cpe2(4)} | read-only | mandatory |
| fc8gPortName OBJECT-TYPE Port name. | 1.3.6.1.4.1.4253.1.35.3.1.5 | CardName | read-only | mandatory |
| fc8gPortMode OBJECT-TYPE Port mode. | 1.3.6.1.4.1.4253.1.35.3.1.6 | INTEGER {enabled(1), loopback(2)} | read-only | mandatory |
| fc8gPortWavelength OBJECT-TYPE Port wavelength. | 1.3.6.1.4.1.4253.1.35.3.1.7 | DisplayString | read-only | mandatory |
| fc8gPortRxPower OBJECT-TYPE Reported port receive power. | 1.3.6.1.4.1.4253.1.35.3.1.8 | DisplayString | read-only | mandatory |
| fc8gPortTxState OBJECT-TYPE State of port transmitter. | 1.3.6.1.4.1.4253.1.35.3.1.9 | INTEGER {na(0), on(1), off(2)} | read-only | mandatory |
| fc8gPortTxReach OBJECT-TYPE Port optical reach in meters. | 1.3.6.1.4.1.4253.1.35.3.1.10 | INTEGER | read-only | mandatory |
| fc8gPortSfpXfpSerialNumber OBJECT-TYPE Port SFP/XFP serial number. | 1.3.6.1.4.1.4253.1.35.3.1.11 | DisplayString | read-only | mandatory |
| performance OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2 | |||
| current1 OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1 | |||
| systemPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.1 | |||
| sysStatus OBJECT-TYPE The global status of the system as computed based on the traps (events) that are generated. Choices are: Critical, Major, Minor or Normal. | 1.3.6.1.4.1.4253.2.1.1.1 | CardStatus | read-only | mandatory |
| sysClearStatus OBJECT-TYPE Reset the system state to Normal. The value of reset means set the state to Normal. A get on this will always return other. Note: This element is now made not-accessible as sysStatus is now a read-only element | 1.3.6.1.4.1.4253.2.1.1.2 | ResetType | not-accessible | mandatory |
| sysClearCounters OBJECT-TYPE Reset all performance counters in this 15 minutes time interval to zero. The value of reset means to reset the counters to zero. A get on this will always return other. | 1.3.6.1.4.1.4253.2.1.1.3 | ResetType | read-write | mandatory |
| sysLastBootTime OBJECT-TYPE The date and time of the last system boot. This time represents the boot time of a CP card. It is also anonymous with the power-up cycle of the chassis. | 1.3.6.1.4.1.4253.2.1.1.4 | DateAndTime | read-only | mandatory |
| sysAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that the system has been up and running. This will generally be the same as 15 minutes in seconds (900), but, if the system has been reboot in the last 15 minutes interval, then it represents the number of seconds the system has been up. The criteria for the system available time is having at least one CP running with atmost non-service affecting minor alarm system status | 1.3.6.1.4.1.4253.2.1.1.5 | Counter | read-only | mandatory |
| sysErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that the device has not experienced any alarms. This counter is across all cards in the chassis. The system must be in Normal status for this counter to be incremented. | 1.3.6.1.4.1.4253.2.1.1.6 | Counter | read-only | mandatory |
| sysExhaustTemperature OBJECT-TYPE Temperature of the Chassis. Units of dgree centigrade. | 1.3.6.1.4.1.4253.2.1.1.7 | INTEGER | read-only | mandatory |
| downloadPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.2 | |||
| dlStatus OBJECT-TYPE The global status of the download task. The download task (download to the device) is either ftp_inprogress, module update inprogrss or currently idle. Since only one download at the time is handled by the system, this flag is set to inprogress as soon as any download starts. It is reset back to idle when the download is completed. This flag is set to idle on system startup. This flag can be remotely set to idle if a previous FTP download was interrupted. | 1.3.6.1.4.1.4253.2.1.2.1 | DownloadStatus | read-write | mandatory |
| dlOkDownloads OBJECT-TYPE The number of successful downloads in this time interval (15 minutes). | 1.3.6.1.4.1.4253.2.1.2.2 | Counter | read-only | mandatory |
| dlBadDownloads OBJECT-TYPE The number of failed downloads in this time interval (15 minutes). | 1.3.6.1.4.1.4253.2.1.2.3 | Counter | read-only | mandatory |
| dlLongestTime OBJECT-TYPE Longest time for any download, in seconds, in this time interval (15 minutes). | 1.3.6.1.4.1.4253.2.1.2.4 | Gauge | read-only | mandatory |
| dlLongestSize OBJECT-TYPE Longest download size for any download, in bytes, in this time interval (15 minutes). | 1.3.6.1.4.1.4253.2.1.2.5 | Gauge | read-only | mandatory |
| cpPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.3 | |||
| cpNumEvents OBJECT-TYPE Total number of events received by the active CP in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.3.1 | Counter | read-only | mandatory |
| cpTrapsSent OBJECT-TYPE Total number of traps sent by the active CP in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.3.2 | Counter | read-only | mandatory |
| cpSNMPCmdsRcvd OBJECT-TYPE Total number of SNMP commands received by the active CP in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.3.3 | Counter | read-only | mandatory |
| cpCounterFlag OBJECT-TYPE Turns software counters On or Off. | 1.3.6.1.4.1.4253.2.1.3.4 | FlagType | read-write | mandatory |
| cpCntrTable OBJECT-TYPE This table represents the information for each entry of the software counters. It is only applicable to the active MPM card. | 1.3.6.1.4.1.4253.2.1.3.5 | not-accessible | mandatory | |
| cpCntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.3.5.1 | not-accessible | mandatory | |
| cpCntrShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the value of the current active CP card. | 1.3.6.1.4.1.4253.2.1.3.5.1.1 | CardShelf | read-only | mandatory |
| cpCntrSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the value of the current active CP card. | 1.3.6.1.4.1.4253.2.1.3.5.1.2 | CardSlot | read-only | mandatory |
| cpCntrType OBJECT-TYPE The type of the software counter data in this row. The data is collected for the SPI data channels. | 1.3.6.1.4.1.4253.2.1.3.5.1.3 | INTEGER {spi(1)} | read-only | mandatory |
| cpTotPktSent OBJECT-TYPE The number of data packets sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.3.5.1.4 | Counter | read-only | mandatory |
| cpTotPktRcvd OBJECT-TYPE The number of data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.3.5.1.5 | Counter | read-only | mandatory |
| cpBadPktRcvd OBJECT-TYPE The number of bad data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.3.5.1.6 | Counter | read-only | mandatory |
| cpTotBadTrans OBJECT-TYPE The number of bad data transmissions over the given data channel. | 1.3.6.1.4.1.4253.2.1.3.5.1.7 | Counter | read-only | mandatory |
| cpBytesSent OBJECT-TYPE Total number of bytes sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.3.5.1.8 | Counter | read-only | mandatory |
| cpBytesRcvd OBJECT-TYPE Total number of data bytes received over the given data channel. | 1.3.6.1.4.1.4253.2.1.3.5.1.9 | Counter | read-only | mandatory |
| cpMsgsDlvrd OBJECT-TYPE The number of complete messages delivered over the given data channel. | 1.3.6.1.4.1.4253.2.1.3.5.1.10 | Counter | read-only | mandatory |
| cpBufAllocFail OBJECT-TYPE Number of buffer allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.1.3.5.1.11 | Counter | read-only | mandatory |
| cpEcbAllocFail OBJECT-TYPE Number of Event Control Block allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.1.3.5.1.12 | Counter | read-only | mandatory |
| cpClearCntrs OBJECT-TYPE If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other | 1.3.6.1.4.1.4253.2.1.3.5.1.13 | ResetType | read-write | mandatory |
| cpPerfTable OBJECT-TYPE This table represents the information for performance data collected for each communication processor | 1.3.6.1.4.1.4253.2.1.3.6 | not-accessible | mandatory | |
| cpPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.3.6.1 | not-accessible | mandatory | |
| cpPerfShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2 | 1.3.6.1.4.1.4253.2.1.3.6.1.1 | CardShelf | read-only | mandatory |
| cpPerfSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 3 | 1.3.6.1.4.1.4253.2.1.3.6.1.2 | CardSlot | read-only | mandatory |
| cpPerfMode OBJECT-TYPE The valid types are: active CP or standby CP | 1.3.6.1.4.1.4253.2.1.3.6.1.3 | RedundancyMode | read-only | mandatory |
| cpPerfState OBJECT-TYPE The status of the communication card. The status' are: online, offline, empty, loopback or diagnostics. | 1.3.6.1.4.1.4253.2.1.3.6.1.4 | CardState | read-only | mandatory |
| cpPerfStatus OBJECT-TYPE The status of the communication processor. This status represents the state of the communication processor and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.3.6.1.5 | CardStatus | read-only | mandatory |
| cpLastBootTime OBJECT-TYPE The date and time of the last boot for this CP. | 1.3.6.1.4.1.4253.2.1.3.6.1.6 | DateAndTime | read-only | mandatory |
| cpAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this CP has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.3.6.1.7 | Counter | read-only | mandatory |
| cpErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this CP has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.3.6.1.8 | Counter | read-only | mandatory |
| ccPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.4 | |||
| ccNumEvents OBJECT-TYPE Total number of events received for all CC's in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.4.1 | Counter | read-only | mandatory |
| ccCntrTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.1.4.2 | not-accessible | mandatory | |
| ccCntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.4.2.1 | not-accessible | mandatory | |
| ccCntrLocation OBJECT-TYPE The location of the CC card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known CC cards. | 1.3.6.1.4.1.4253.2.1.4.2.1.1 | CardLocation | read-only | mandatory |
| ccCntrShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) CC cards. | 1.3.6.1.4.1.4253.2.1.4.2.1.2 | CardShelf | read-only | mandatory |
| ccCntrSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) CC cards. | 1.3.6.1.4.1.4253.2.1.4.2.1.3 | CardSlot | read-only | mandatory |
| ccCntrType OBJECT-TYPE The type of the software counter data in this row. The data is collected for the SPI data channels. | 1.3.6.1.4.1.4253.2.1.4.2.1.4 | INTEGER {spi(1), iwm(2)} | read-only | mandatory |
| ccCounterFlag OBJECT-TYPE Turns software counters, both On or both Off for this CC. When set to Off, both counters statistic information will be cleared. | 1.3.6.1.4.1.4253.2.1.4.2.1.5 | FlagType | read-write | mandatory |
| ccTotPktSent OBJECT-TYPE The number of data packets sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.4.2.1.6 | Counter | read-only | mandatory |
| ccTotPktRcvd OBJECT-TYPE The number of data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.4.2.1.7 | Counter | read-only | mandatory |
| ccBadPktRcvd OBJECT-TYPE The number of bad data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.4.2.1.8 | Counter | read-only | mandatory |
| ccTotBadTrans OBJECT-TYPE The number of bad data transmissions over the given data channel. | 1.3.6.1.4.1.4253.2.1.4.2.1.9 | Counter | read-only | mandatory |
| ccBytesSent OBJECT-TYPE Total number of bytes sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.4.2.1.10 | Counter | read-only | mandatory |
| ccBytesRcvd OBJECT-TYPE Total number of data bytes received over the given data channel. | 1.3.6.1.4.1.4253.2.1.4.2.1.11 | Counter | read-only | mandatory |
| ccMsgsDlvrd OBJECT-TYPE The number of complete messages delivered over the given data channel. | 1.3.6.1.4.1.4253.2.1.4.2.1.12 | Counter | read-only | mandatory |
| ccBufAllocFail OBJECT-TYPE Number of buffer allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.1.4.2.1.13 | Counter | read-only | mandatory |
| ccEcbAllocFail OBJECT-TYPE Number of Event Control Block allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.1.4.2.1.14 | Counter | read-only | mandatory |
| ccClearCntrs OBJECT-TYPE If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other | 1.3.6.1.4.1.4253.2.1.4.2.1.15 | ResetType | read-write | mandatory |
| ccPerfTable OBJECT-TYPE This table represents the information for performance data collected for each channel card | 1.3.6.1.4.1.4253.2.1.4.3 | not-accessible | mandatory | |
| ccPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.4.3.1 | not-accessible | mandatory | |
| ccPerfLocation OBJECT-TYPE The location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) CC cards. | 1.3.6.1.4.1.4253.2.1.4.3.1.1 | CardLocation | read-only | mandatory |
| ccPerfShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.1.4.3.1.2 | CardShelf | read-only | mandatory |
| ccPerfSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 4 to 42 | 1.3.6.1.4.1.4253.2.1.4.3.1.3 | CardSlot | read-only | mandatory |
| ccPerfState OBJECT-TYPE The state of the channel card. The states' are: online, offline, empty, loopback or diagnostics. | 1.3.6.1.4.1.4253.2.1.4.3.1.4 | CardState | read-only | mandatory |
| ccPerfStatus OBJECT-TYPE The status of the channel card. This status represents the status of the communication processor and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.4.3.1.5 | CardStatus | read-only | mandatory |
| ccLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.1.4.3.1.6 | DateAndTime | read-only | mandatory |
| ccAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this CC has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.4.3.1.7 | Counter | read-only | mandatory |
| ccErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this CC has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.4.3.1.8 | Counter | read-only | mandatory |
| ccBiasCurrent OBJECT-TYPE Bias current for the optical laser. | 1.3.6.1.4.1.4253.2.1.4.3.1.9 | INTEGER | read-only | mandatory |
| ccModulation OBJECT-TYPE The frequency modulation for the optical laser. | 1.3.6.1.4.1.4253.2.1.4.3.1.10 | INTEGER | read-only | mandatory |
| ccApc OBJECT-TYPE The APC value. | 1.3.6.1.4.1.4253.2.1.4.3.1.11 | INTEGER | read-only | mandatory |
| ccIwmModulation OBJECT-TYPE The frequency modulation for the IWM channel. | 1.3.6.1.4.1.4253.2.1.4.3.1.12 | INTEGER | read-only | mandatory |
| ccLaserOnOff OBJECT-TYPE The laser On/Off flag. | 1.3.6.1.4.1.4253.2.1.4.3.1.13 | FlagType | read-only | mandatory |
| ccTemperature OBJECT-TYPE The current temperature, or the operating temperature of the optical device. | 1.3.6.1.4.1.4253.2.1.4.3.1.14 | Gauge | read-only | mandatory |
| ccIntensity OBJECT-TYPE The intensity of the optical light. | 1.3.6.1.4.1.4253.2.1.4.3.1.15 | Gauge | read-only | mandatory |
| ccSignalStrength OBJECT-TYPE The current signal strength for the optical path. | 1.3.6.1.4.1.4253.2.1.4.3.1.16 | Gauge | read-only | mandatory |
| ccLossOfLight OBJECT-TYPE If set to true, no laser light is present. If set to false, no loss of light has occurred. | 1.3.6.1.4.1.4253.2.1.4.3.1.17 | Boolean | read-only | mandatory |
| ccSignalDetect OBJECT-TYPE If set to true, signal is detected. If set to false, no signal is present. Replaced with ccCpeRxSigDetect | 1.3.6.1.4.1.4253.2.1.4.3.1.18 | Boolean | not-accessible | mandatory |
| ccRefClock OBJECT-TYPE The value of the reference clock in decimal notation. For a given value, like 1660, the actual value is 16.60-EN. In otherwords, assume a two digit decimal point, plus any appropriate scaling factor. | 1.3.6.1.4.1.4253.2.1.4.3.1.19 | INTEGER {en1660(1), en1944(2), en1953(3)} | not-accessible | mandatory |
| ccClockDiv OBJECT-TYPE The clock divisor. Values are 1250, 622 or 155 in the appropriate clock frequency scale. | 1.3.6.1.4.1.4253.2.1.4.3.1.20 | INTEGER {dout-1250(1), dout-622(2), dout-155(3)} | not-accessible | mandatory |
| ccLinkTxPwrStatus OBJECT-TYPE This indicates whether the link transmit power is within the normal range of operation. | 1.3.6.1.4.1.4253.2.1.4.3.1.21 | INTEGER {ok(1), fault(2)} | read-only | mandatory |
| ccLinkRxSigStrStatus OBJECT-TYPE This indicates whether the link's receive signal is within the normal range of operation. | 1.3.6.1.4.1.4253.2.1.4.3.1.22 | INTEGER {ok(1), fault(2)} | read-only | mandatory |
| ccCpeRxSigDetect OBJECT-TYPE This indicates whether there is presence of CPE receive signal | 1.3.6.1.4.1.4253.2.1.4.3.1.23 | INTEGER {yes(1), no(2)} | read-only | mandatory |
| ccLinkIWMStatus OBJECT-TYPE This indicates the current status of IWM. This value is only applicable to remote OCMs | 1.3.6.1.4.1.4253.2.1.4.3.1.24 | INTEGER {ok(1), error(2), notApplicable(3)} | read-only | mandatory |
| ccLinkSummaryStatus OBJECT-TYPE This is the result of a logical and operation of all the individual link status. If any of the attributes is N/A, except for the local local IWM status, this value is N/A | 1.3.6.1.4.1.4253.2.1.4.3.1.25 | INTEGER {ok(1), fault(2), notApplicable(3)} | read-only | mandatory |
| ccProtectionMode OBJECT-TYPE UPSR Protection Mode: active, standby and n/a. | 1.3.6.1.4.1.4253.2.1.4.3.1.26 | INTEGER {working(1), protection(2), na(3)} | read-only | mandatory |
| ccLinkRxSigStr OBJECT-TYPE Link's received signal strength in dBm. | 1.3.6.1.4.1.4253.2.1.4.3.1.27 | DisplayString | read-only | mandatory |
| muxPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.5 | |||
| muxNumEvents OBJECT-TYPE Total number of all traps (events) generated by all MUX's in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.5.1 | Counter | read-only | mandatory |
| muxPerfTable OBJECT-TYPE This table represents the information for performance data collected for each mux/demux card | 1.3.6.1.4.1.4253.2.1.5.2 | not-accessible | mandatory | |
| muxPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.5.2.1 | not-accessible | mandatory | |
| muxPerfLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.1.5.2.1.1 | CardLocation | read-only | mandatory |
| muxPerfShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.1.5.2.1.2 | CardShelf | read-only | mandatory |
| muxPerfSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 42 | 1.3.6.1.4.1.4253.2.1.5.2.1.3 | CardSlot | read-only | mandatory |
| muxType OBJECT-TYPE The type of the mux. The choices are: mux or demux. | 1.3.6.1.4.1.4253.2.1.5.2.1.4 | CardType | read-only | mandatory |
| muxPerfState OBJECT-TYPE The state of the mux card. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.1.5.2.1.5 | CardState | read-only | mandatory |
| muxPerfStatus OBJECT-TYPE The status of the mux card. This status represents the status of the mux card and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.5.2.1.6 | CardStatus | read-only | mandatory |
| muxLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.1.5.2.1.7 | DateAndTime | read-only | mandatory |
| muxAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this Mux has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.5.2.1.8 | Counter | read-only | mandatory |
| muxErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this mux has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.5.2.1.9 | Counter | read-only | mandatory |
| psPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.6 | |||
| psNumEvents OBJECT-TYPE Total number of all traps (events) generated by all Power Supplies in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.6.1 | Counter | read-only | mandatory |
| psVoltageLevel3pt4Volt OBJECT-TYPE Voltage Level of the 3.4 V power supply. | 1.3.6.1.4.1.4253.2.1.6.2 | DisplayString (SIZE(0..10)) | read-only | mandatory |
| psVoltageLevel5pt1Volt OBJECT-TYPE Voltage Level of the 5.1 V power supply. | 1.3.6.1.4.1.4253.2.1.6.3 | DisplayString (SIZE(0..10)) | read-only | mandatory |
| psVoltageLevel12Volt OBJECT-TYPE Voltage Level of the 12 V power supply. | 1.3.6.1.4.1.4253.2.1.6.4 | DisplayString (SIZE(0..10)) | read-only | mandatory |
| psPerfTable OBJECT-TYPE This table represents the information for performance data collected for each power supply card | 1.3.6.1.4.1.4253.2.1.6.5 | not-accessible | mandatory | |
| psPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.6.5.1 | not-accessible | mandatory | |
| psPerfID OBJECT-TYPE The module ID where the PS is plugged in. | 1.3.6.1.4.1.4253.2.1.6.5.1.1 | INTEGER | read-only | mandatory |
| psPerfType OBJECT-TYPE The type of the power supply. | 1.3.6.1.4.1.4253.2.1.6.5.1.2 | INTEGER {psDC(1), psAC(2), unknown(3)} | read-only | mandatory |
| psPerfState OBJECT-TYPE The state of the power supply module. | 1.3.6.1.4.1.4253.2.1.6.5.1.3 | INTEGER {psEmpty(1), psOK(2), psFailed(3), psDegrade(4)} | read-only | mandatory |
| psPerfStatus OBJECT-TYPE The status of the power supply module. This status represents the status of the ps module and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.6.5.1.4 | CardStatus | read-only | mandatory |
| psVoltageLevelFeedA OBJECT-TYPE Voltage Level of the -48 VDC input from Feed A. | 1.3.6.1.4.1.4253.2.1.6.6 | DisplayString (SIZE(0..10)) | read-only | mandatory |
| psVoltageLevelFeedB OBJECT-TYPE Voltage Level of the -48 VDC input from Feed B. | 1.3.6.1.4.1.4253.2.1.6.7 | DisplayString (SIZE(0..10)) | read-only | mandatory |
| psBreakerConditionFeedA OBJECT-TYPE State of Feed A breaker. | 1.3.6.1.4.1.4253.2.1.6.8 | INTEGER {open(1), closed(2), na(3)} | read-only | mandatory |
| psPerfStatusFeedA OBJECT-TYPE State of Feed A breaker. Failed if it goes into shutdown condition Unknown if the corresponding breaker is open | 1.3.6.1.4.1.4253.2.1.6.9 | INTEGER {feedOK(1), feedFAILED(2), feedUNKNOWN(3), na(4)} | read-only | mandatory |
| psBreakerConditionFeedB OBJECT-TYPE State of Feed B breaker. | 1.3.6.1.4.1.4253.2.1.6.10 | INTEGER {open(1), closed(2), na(3)} | read-only | mandatory |
| psPerfStatusFeedB OBJECT-TYPE State of Feed B. Failed if it goes into shutdown condition Unknown if the corresponding breaker is open | 1.3.6.1.4.1.4253.2.1.6.11 | INTEGER {feedOK(1), feedFAILED(2), feedUNKNOWN(3), na(4)} | read-only | mandatory |
| fadmPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.7 | |||
| fadmNumEvents OBJECT-TYPE Total number of all traps (events) generated by all MUX's in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.7.1 | Counter | read-only | mandatory |
| fadmPerfTable OBJECT-TYPE This table represents the information for performance data collected for each fadm card | 1.3.6.1.4.1.4253.2.1.7.2 | not-accessible | mandatory | |
| fadmPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.7.2.1 | not-accessible | mandatory | |
| fadmPerfLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.1.7.2.1.1 | CardLocation | read-only | mandatory |
| fadmPerfShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.1.7.2.1.2 | CardShelf | read-only | mandatory |
| fadmPerfSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 42 | 1.3.6.1.4.1.4253.2.1.7.2.1.3 | CardSlot | read-only | mandatory |
| fadmPerfState OBJECT-TYPE The status of the fadm card. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.1.7.2.1.4 | CardState | read-only | mandatory |
| fadmPerfStatus OBJECT-TYPE The status of the fadm card. This status represents the status of the fadm card and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.7.2.1.5 | CardStatus | read-only | mandatory |
| fadmLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.1.7.2.1.6 | DateAndTime | read-only | mandatory |
| fadmAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this fadm card has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.7.2.1.7 | Counter | read-only | mandatory |
| fadmErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this fadm card has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.7.2.1.8 | Counter | read-only | mandatory |
| oppmPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.8 | |||
| oppmNumEvents OBJECT-TYPE Total number of all traps (events) generated by all OPPM's in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.8.1 | Counter | not-accessible | mandatory |
| oppmPerfTable OBJECT-TYPE This table represents the information for performance data collected for each oppm card | 1.3.6.1.4.1.4253.2.1.8.2 | not-accessible | mandatory | |
| oppmPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.8.2.1 | not-accessible | mandatory | |
| oppmPerfLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.1.8.2.1.1 | CardLocation | not-accessible | mandatory |
| oppmPerfShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.1.8.2.1.2 | CardShelf | not-accessible | mandatory |
| oppmPerfSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 4 to 42 | 1.3.6.1.4.1.4253.2.1.8.2.1.3 | CardSlot | not-accessible | mandatory |
| oppmPerfState OBJECT-TYPE The state of the oppm card. The states are: online, offline. | 1.3.6.1.4.1.4253.2.1.8.2.1.4 | CardState | not-accessible | mandatory |
| oppmPerfStatus OBJECT-TYPE The status of the oppm card. This status represents the status of the oppm card and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.8.2.1.5 | CardStatus | not-accessible | mandatory |
| oppmLinkAState OBJECT-TYPE The state of the oppm card. The states are: linked, notLinked. | 1.3.6.1.4.1.4253.2.1.8.2.1.6 | INTEGER {linked(1), notLinked(2), unknown(3)} | not-accessible | mandatory |
| oppmLinkAStatus OBJECT-TYPE The status of the card channel. This status represents the status of the link A of the card and in general is different from the status of the card. | 1.3.6.1.4.1.4253.2.1.8.2.1.7 | INTEGER {active(1), standby(2), hibernation(3)} | not-accessible | mandatory |
| oppmLinkBState OBJECT-TYPE The state of the oppm card link B. The states are: linked, notLinked. | 1.3.6.1.4.1.4253.2.1.8.2.1.8 | INTEGER {linked(1), notLinked(2), unknown(3)} | not-accessible | mandatory |
| oppmLinkBStatus OBJECT-TYPE The status of the card channel. This status represents the status of the link B of the card and in general is different from the status of the card. | 1.3.6.1.4.1.4253.2.1.8.2.1.9 | INTEGER {active(1), standby(2), hibernation(3)} | not-accessible | mandatory |
| oppmLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.1.8.2.1.10 | DateAndTime | not-accessible | mandatory |
| oppmAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this oppm card has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.8.2.1.11 | Counter | not-accessible | mandatory |
| oppmErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this oppm card has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.8.2.1.12 | Counter | not-accessible | mandatory |
| oppmWorkingPower OBJECT-TYPE working power displayed in dBm unit | 1.3.6.1.4.1.4253.2.1.8.2.1.13 | INTEGER | not-accessible | mandatory |
| oppmProtectPower OBJECT-TYPE protect power displayed in dBm unit | 1.3.6.1.4.1.4253.2.1.8.2.1.14 | INTEGER | not-accessible | mandatory |
| mcmPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.9 | |||
| mcmNumEvents OBJECT-TYPE Total number of events received for all mcmt1's/mcme1's in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.9.1 | Counter | read-only | mandatory |
| mcmCntrTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.1.9.2 | not-accessible | mandatory | |
| mcmCntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.9.2.1 | not-accessible | mandatory | |
| mcmCntrLocation OBJECT-TYPE The location of the mcmt1/mcme1 card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmt1/mcme1 cards. | 1.3.6.1.4.1.4253.2.1.9.2.1.1 | CardLocation | read-only | mandatory |
| mcmCntrShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards. | 1.3.6.1.4.1.4253.2.1.9.2.1.2 | CardShelf | read-only | mandatory |
| mcmCntrSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 21. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards. | 1.3.6.1.4.1.4253.2.1.9.2.1.3 | CardSlot | read-only | mandatory |
| mcmCntrType OBJECT-TYPE The type of the software counter data in this row. The data is collected for the SPI data channels. | 1.3.6.1.4.1.4253.2.1.9.2.1.4 | INTEGER {spi(1), iwm(2)} | read-only | mandatory |
| mcmCounterFlag OBJECT-TYPE Turns software counters On or Off for this mcmt1/mcme1. | 1.3.6.1.4.1.4253.2.1.9.2.1.5 | FlagType | read-write | mandatory |
| mcmTotPktSent OBJECT-TYPE The number of data packets sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.9.2.1.6 | Counter | read-only | mandatory |
| mcmTotPktRcvd OBJECT-TYPE The number of data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.9.2.1.7 | Counter | read-only | mandatory |
| mcmBadPktRcvd OBJECT-TYPE The number of bad data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.9.2.1.8 | Counter | read-only | mandatory |
| mcmTotBadTrans OBJECT-TYPE The number of bad data transmissions over the given data channel. | 1.3.6.1.4.1.4253.2.1.9.2.1.9 | Counter | read-only | mandatory |
| mcmBytesSent OBJECT-TYPE Total number of bytes sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.9.2.1.10 | Counter | read-only | mandatory |
| mcmBytesRcvd OBJECT-TYPE Total number of data bytes received over the given data channel. | 1.3.6.1.4.1.4253.2.1.9.2.1.11 | Counter | read-only | mandatory |
| mcmMsgsDlvrd OBJECT-TYPE The number of complete messages delivered over the given data channel. | 1.3.6.1.4.1.4253.2.1.9.2.1.12 | Counter | read-only | mandatory |
| mcmBufAllocFail OBJECT-TYPE Number of buffer allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.1.9.2.1.13 | Counter | read-only | mandatory |
| mcmEcbAllocFail OBJECT-TYPE Number of Event Control Block allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.1.9.2.1.14 | Counter | read-only | mandatory |
| mcmClearCntrs OBJECT-TYPE If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other | 1.3.6.1.4.1.4253.2.1.9.2.1.15 | ResetType | read-write | mandatory |
| mcmPerfTable OBJECT-TYPE This table represents the information for performance data collected for each mcmt1/mcme1 card | 1.3.6.1.4.1.4253.2.1.9.3 | not-accessible | mandatory | |
| mcmPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.9.3.1 | not-accessible | mandatory | |
| mcmPerfLocation OBJECT-TYPE The location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) mcmt1/mcme1 cards. | 1.3.6.1.4.1.4253.2.1.9.3.1.1 | CardLocation | read-only | mandatory |
| mcmPerfShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 3 | 1.3.6.1.4.1.4253.2.1.9.3.1.2 | CardShelf | read-only | mandatory |
| mcmPerfSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 21 | 1.3.6.1.4.1.4253.2.1.9.3.1.3 | CardSlot | read-only | mandatory |
| mcmPerfState OBJECT-TYPE The state of the mcmt1/mcme1 card. The states' are: online, offline, empty, loopback or diagnostics. | 1.3.6.1.4.1.4253.2.1.9.3.1.4 | CardState | read-only | mandatory |
| mcmPerfStatus OBJECT-TYPE The status of the channel card. This status represents the status of the communication processor and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.9.3.1.5 | CardStatus | read-only | mandatory |
| mcmLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.1.9.3.1.6 | DateAndTime | read-only | mandatory |
| mcmAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this mcmt1/mcme1 has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.9.3.1.7 | Counter | read-only | mandatory |
| mcmErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this mcmt1/mcme1 has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.9.3.1.8 | Counter | read-only | mandatory |
| mcmBiasCurrent OBJECT-TYPE Bias current for the optical laser. This value can be set remotely | 1.3.6.1.4.1.4253.2.1.9.3.1.9 | INTEGER | read-only | mandatory |
| mcmModulation OBJECT-TYPE The frequency modulation for the optical laser. This value can be adjusted remotely. | 1.3.6.1.4.1.4253.2.1.9.3.1.10 | INTEGER | read-only | mandatory |
| mcmApc OBJECT-TYPE The APC value. This value can be set remotely. | 1.3.6.1.4.1.4253.2.1.9.3.1.11 | INTEGER | read-only | mandatory |
| mcmIwmModulation OBJECT-TYPE The frequency modulation for the IWM channel. This value can be adjusted remotely. | 1.3.6.1.4.1.4253.2.1.9.3.1.12 | INTEGER | read-only | mandatory |
| mcmLaserOnOff OBJECT-TYPE The laser On/Off flag. This value can be set remotely. | 1.3.6.1.4.1.4253.2.1.9.3.1.13 | FlagType | read-only | mandatory |
| mcmTemperature OBJECT-TYPE The current temperature, or the operating temperature of the optical device. | 1.3.6.1.4.1.4253.2.1.9.3.1.14 | Gauge | read-only | mandatory |
| mcmIntensity OBJECT-TYPE The intensity of the optical light. This value can be set remotely. | 1.3.6.1.4.1.4253.2.1.9.3.1.15 | Gauge | read-only | mandatory |
| mcmSignalStrength OBJECT-TYPE The current signal strength for the optical path. | 1.3.6.1.4.1.4253.2.1.9.3.1.16 | Gauge | read-only | mandatory |
| mcmLossOfLight OBJECT-TYPE If set to true, no laser light is present. If set to false, no loss of light has occurred. | 1.3.6.1.4.1.4253.2.1.9.3.1.17 | Boolean | read-only | mandatory |
| mcmSignalDetect OBJECT-TYPE If set to true, signal is detected. If set to false, no signal is present. | 1.3.6.1.4.1.4253.2.1.9.3.1.18 | Boolean | read-only | mandatory |
| mcmPortCurrTable OBJECT-TYPE This table represents the information for each MCMT1/MCME1 port's current counters. | 1.3.6.1.4.1.4253.2.1.9.4 | not-accessible | mandatory | |
| mcmPortCurrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.9.4.1 | not-accessible | mandatory | |
| mcmPortCurrCardLocation OBJECT-TYPE Location of the MCMT1/MCME1 port. Valid values are: Local in the same chassis, or remote to this chassis | 1.3.6.1.4.1.4253.2.1.9.4.1.1 | CardLocation | read-only | mandatory |
| mcmPortCurrCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 2..3. | 1.3.6.1.4.1.4253.2.1.9.4.1.2 | CardShelf | read-only | mandatory |
| mcmPortCurrCardSlot OBJECT-TYPE The slot within the shelf the Module is in. | 1.3.6.1.4.1.4253.2.1.9.4.1.3 | CardSlot | read-only | mandatory |
| mcmPortCurrIndex OBJECT-TYPE Port's index. | 1.3.6.1.4.1.4253.2.1.9.4.1.4 | INTEGER | read-only | mandatory |
| mcmPortCurrASs OBJECT-TYPE MCMT1/MCME1 port's ASs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.1.9.4.1.5 | Counter | read-only | mandatory |
| mcmPortCurrFrameASs OBJECT-TYPE MCMT1/MCME1 port's FrameASs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.1.9.4.1.6 | Counter | not-accessible | mandatory |
| mcmPortCurrFEs OBJECT-TYPE MCMT1/MCME1 port's FEs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.1.9.4.1.7 | Counter | read-only | mandatory |
| mcmPortCurrCRCErrs OBJECT-TYPE MCMT1/MCME1 port's CRC errs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.1.9.4.1.8 | Counter | read-only | mandatory |
| mcmPortCurrSESs OBJECT-TYPE MCMT1/MCME1 port's SESs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.1.9.4.1.9 | Counter | read-only | mandatory |
| mcmPortCurrSEFSs OBJECT-TYPE MCMT1/MCME1 port's SEFSs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.1.9.4.1.10 | Counter | read-only | mandatory |
| mcmPortCurrUASs OBJECT-TYPE MCMT1/MCME1 port's UASs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.1.9.4.1.11 | Counter | read-only | mandatory |
| mcmPortCurrLESs OBJECT-TYPE MCMT1/MCME1 port's LESs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.1.9.4.1.12 | Counter | read-only | mandatory |
| mcmPortCurrBESs OBJECT-TYPE MCMT1/MCME1 port's BESs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.1.9.4.1.13 | Counter | read-only | mandatory |
| mcmPortCurrDMs OBJECT-TYPE MCMT1/MCME1 port's DMSs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.1.9.4.1.14 | Counter | read-only | mandatory |
| mcmPortCurrLCVs OBJECT-TYPE MCMT1/MCME1 port's LCVs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.1.9.4.1.15 | Counter | read-only | mandatory |
| fnPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.10 | |||
| fnNumEvents OBJECT-TYPE Total number of all traps (events) generated by all Fans in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.10.1 | Counter | read-only | mandatory |
| fnPerfTable OBJECT-TYPE This table represents the information for performance data collected for each fan module. | 1.3.6.1.4.1.4253.2.1.10.2 | not-accessible | mandatory | |
| fnPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.10.2.1 | not-accessible | mandatory | |
| fnPerfID OBJECT-TYPE The module ID where the fan module is plugged in. | 1.3.6.1.4.1.4253.2.1.10.2.1.1 | INTEGER | read-only | mandatory |
| fnPerfState OBJECT-TYPE The state of the fan module. | 1.3.6.1.4.1.4253.2.1.10.2.1.2 | INTEGER {fnEmpty(1), fnOK(2), fnFailed(3), fnDegrade(4)} | read-only | mandatory |
| fnPerfStatus OBJECT-TYPE The status of the fan module. This status represents the status of the fan module and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.10.2.1.3 | CardStatus | read-only | mandatory |
| csimPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.11 | |||
| csimNumEvents OBJECT-TYPE This variable keeps track of the number of events related to ColorSIM. The reason this has been made obsolete is that all colorsim related events would eventually be part of ocm events | 1.3.6.1.4.1.4253.2.1.11.1 | Counter | not-accessible | mandatory |
| csimCurrentTable OBJECT-TYPE This table represents the information for each colorsim card in the most current interval | 1.3.6.1.4.1.4253.2.1.11.2 | not-accessible | mandatory | |
| csimCurrentEntry OBJECT-TYPE Specifies the index for each row in the table below. | 1.3.6.1.4.1.4253.2.1.11.2.1 | not-accessible | mandatory | |
| csimCurrentLocation OBJECT-TYPE Location of the ColorSIM module | 1.3.6.1.4.1.4253.2.1.11.2.1.1 | CardLocation | read-only | mandatory |
| csimCurrentShelf OBJECT-TYPE The shelf of the ColorSIM module | 1.3.6.1.4.1.4253.2.1.11.2.1.2 | CardShelf | read-only | mandatory |
| csimCurrentSlot OBJECT-TYPE The Slot of the ColorSIM module | 1.3.6.1.4.1.4253.2.1.11.2.1.3 | CardSlot | read-only | mandatory |
| csimCurrentEFIs OBJECT-TYPE The counter associated with the number of Error Free Interval Counts in the current update (default: 15 minutes) interval. | 1.3.6.1.4.1.4253.2.1.11.2.1.4 | INTEGER | read-only | mandatory |
| csimCurrentEIs OBJECT-TYPE The counter associated with the number of Errored Interval Counts in the current update (default: 15 minutes) interval. | 1.3.6.1.4.1.4253.2.1.11.2.1.5 | INTEGER | read-only | mandatory |
| csimCurrentSEIs OBJECT-TYPE The counter associated with the number of Severly Errored Interval Counts in the current update (default:15 minutes) interval. | 1.3.6.1.4.1.4253.2.1.11.2.1.6 | INTEGER | read-only | mandatory |
| csimCurrentBERs OBJECT-TYPE The counter associated with the number of Bit Error Rates Counts in the current update (default: 15 minutes) interval. The unit will be in the form of x.ye-z. | 1.3.6.1.4.1.4253.2.1.11.2.1.7 | DisplayString | read-only | mandatory |
| csimCurrentUAIs OBJECT-TYPE The counter associated with the number of Unavailable Interval Counts in the current update (default: 15 minutes) interval. | 1.3.6.1.4.1.4253.2.1.11.2.1.8 | INTEGER | read-only | mandatory |
| csimCurrentGIs OBJECT-TYPE The number of gating intervals over which the data was collected. | 1.3.6.1.4.1.4253.2.1.11.2.1.9 | INTEGER | read-only | mandatory |
| csimCurrentDateTime OBJECT-TYPE Time in seconds elasped since 01/01/1970 00:00:00 GMT. Assuming local time is same as GMT | 1.3.6.1.4.1.4253.2.1.11.2.1.10 | INTEGER | read-only | mandatory |
| rpsmPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.12 | |||
| rpsmNumEvents OBJECT-TYPE Total number of all traps (events) generated by all RPSM's in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.12.1 | Counter | not-accessible | mandatory |
| rpsmPerfTable OBJECT-TYPE This table represents the information for performance data collected for each rpsm card | 1.3.6.1.4.1.4253.2.1.12.2 | not-accessible | mandatory | |
| rpsmPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.12.2.1 | not-accessible | mandatory | |
| rpsmPerfLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.1.12.2.1.1 | CardLocation | not-accessible | mandatory |
| rpsmPerfShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.1.12.2.1.2 | CardShelf | not-accessible | mandatory |
| rpsmPerfSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.1.12.2.1.3 | CardSlot | not-accessible | mandatory |
| rpsmPerfState OBJECT-TYPE The state of the rpsm card. The possible states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.1.12.2.1.4 | CardState | not-accessible | mandatory |
| rpsmPerfStatus OBJECT-TYPE The status of the rpsm card. This status represents the status of the rpsm card and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.12.2.1.5 | CardStatus | not-accessible | mandatory |
| rpsmLinkEastState OBJECT-TYPE The link state of path East, whether light is being detected. The states are: linked, notLinked. | 1.3.6.1.4.1.4253.2.1.12.2.1.6 | INTEGER {linked(1), notLinked(2), unknown(3)} | not-accessible | mandatory |
| rpsmLinkEastStatus OBJECT-TYPE The status of the card channel. This status represents the status of the link East of the card and in general is different from the status of the card. | 1.3.6.1.4.1.4253.2.1.12.2.1.7 | INTEGER {active(1), standby(2), hibernation(3)} | not-accessible | mandatory |
| rpsmLinkWestState OBJECT-TYPE The link state of path West, whether light is being detected. The states are: linked, notLinked. | 1.3.6.1.4.1.4253.2.1.12.2.1.8 | INTEGER {linked(1), notLinked(2), unknown(3)} | not-accessible | mandatory |
| rpsmLinkWestStatus OBJECT-TYPE The status of the card channel. This status represents the status of the link West of the card and in general is different from the status of the card. | 1.3.6.1.4.1.4253.2.1.12.2.1.9 | INTEGER {active(1), standby(2), hibernation(3)} | not-accessible | mandatory |
| rpsmLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.1.12.2.1.10 | DateAndTime | not-accessible | mandatory |
| rpsmAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this rpsm has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.12.2.1.11 | Counter | not-accessible | mandatory |
| rpsmErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this rpsm has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.12.2.1.12 | Counter | not-accessible | mandatory |
| rpsmWorkingPower OBJECT-TYPE Working link power of the RPSM card in dBm. | 1.3.6.1.4.1.4253.2.1.12.2.1.13 | INTEGER | not-accessible | mandatory |
| rpsmProtectionPower OBJECT-TYPE Protection link power of the RPSM card in dBm. | 1.3.6.1.4.1.4253.2.1.12.2.1.14 | INTEGER | not-accessible | mandatory |
| rsdmPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.13 | |||
| rsdmNumEvents OBJECT-TYPE Total number of all traps (events) generated by all RSDM's in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.13.1 | Counter | not-accessible | mandatory |
| rsdmPerfTable OBJECT-TYPE This table represents the information for performance data collected for each rsdm card | 1.3.6.1.4.1.4253.2.1.13.2 | not-accessible | mandatory | |
| rsdmPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.13.2.1 | not-accessible | mandatory | |
| rsdmPerfLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.1.13.2.1.1 | CardLocation | not-accessible | mandatory |
| rsdmPerfShelf OBJECT-TYPE The shelf the card is in. | 1.3.6.1.4.1.4253.2.1.13.2.1.2 | CardShelf | not-accessible | mandatory |
| rsdmPerfSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.1.13.2.1.3 | CardSlot | not-accessible | mandatory |
| rsdmPerfState OBJECT-TYPE The state of the rsdm card. The states are: online, offline. | 1.3.6.1.4.1.4253.2.1.13.2.1.4 | CardState | not-accessible | mandatory |
| rsdmPerfStatus OBJECT-TYPE The status of the rsdm card. This status represents the status of the rsdm card and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.13.2.1.5 | CardStatus | not-accessible | mandatory |
| rsdmLinkEastState OBJECT-TYPE The link state of path A, whether light is being detected. The states are: linked, notLinked. | 1.3.6.1.4.1.4253.2.1.13.2.1.6 | INTEGER {linked(1), notLinked(2), unknown(3)} | not-accessible | mandatory |
| rsdmLinkEastStatus OBJECT-TYPE The status of the card channel. This status represents the status of the link East of the card and in general is different from the status of the card. | 1.3.6.1.4.1.4253.2.1.13.2.1.7 | INTEGER {active(1), standby(2), hibernation(3)} | not-accessible | mandatory |
| rsdmLinkWestState OBJECT-TYPE The link state of path West, whether light is being detected. The states are: linked, notLinked. | 1.3.6.1.4.1.4253.2.1.13.2.1.8 | INTEGER {linked(1), notLinked(2), unknown(3)} | not-accessible | mandatory |
| rsdmLinkWestStatus OBJECT-TYPE The status of the card channel. This status represents the status of the link West of the card and in general is different from the status of the card. | 1.3.6.1.4.1.4253.2.1.13.2.1.9 | INTEGER {active(1), standby(2), hibernation(3)} | not-accessible | mandatory |
| rsdmLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.1.13.2.1.10 | DateAndTime | not-accessible | mandatory |
| rsdmAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this rsdm card has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.13.2.1.11 | Counter | not-accessible | mandatory |
| rsdmErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this rsdm card has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.13.2.1.12 | Counter | not-accessible | mandatory |
| rsdmWorkingPower OBJECT-TYPE Working link power of the RSDM card in dBm. | 1.3.6.1.4.1.4253.2.1.13.2.1.13 | INTEGER | not-accessible | mandatory |
| rsdmProtectionPower OBJECT-TYPE Protection link power of the RSDM card in dBm. | 1.3.6.1.4.1.4253.2.1.13.2.1.14 | INTEGER | not-accessible | mandatory |
| rtdmPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.14 | |||
| rtdmNumEvents OBJECT-TYPE Total number of all traps (events) generated by all RTDM's in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.14.1 | Counter | not-accessible | mandatory |
| rtdmPerfTable OBJECT-TYPE This table represents the information for performance data collected for each rtdm card | 1.3.6.1.4.1.4253.2.1.14.2 | not-accessible | mandatory | |
| rtdmPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.14.2.1 | not-accessible | mandatory | |
| rtdmPerfLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.1.14.2.1.1 | CardLocation | not-accessible | mandatory |
| rtdmPerfShelf OBJECT-TYPE The shelf the card is in. | 1.3.6.1.4.1.4253.2.1.14.2.1.2 | CardShelf | not-accessible | mandatory |
| rtdmPerfSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.1.14.2.1.3 | CardSlot | not-accessible | mandatory |
| rtdmPerfState OBJECT-TYPE The state of the rtdm card. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.1.14.2.1.4 | CardState | not-accessible | mandatory |
| rtdmPerfStatus OBJECT-TYPE The status of the rtdm card. This status represents the status of the rtdm card and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.14.2.1.5 | CardStatus | not-accessible | mandatory |
| rtdmLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.1.14.2.1.6 | DateAndTime | not-accessible | mandatory |
| rtdmAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this rtdm has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.14.2.1.7 | Counter | not-accessible | mandatory |
| rtdmErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this rtdm has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.14.2.1.8 | Counter | not-accessible | mandatory |
| osamPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.15 | |||
| osamNumEvents OBJECT-TYPE Total number of events received for all osam's in the most current 15 minutes slot. | 1.3.6.1.4.1.4253.2.1.15.1 | Counter | read-only | mandatory |
| osamCntrTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.1.15.2 | not-accessible | mandatory | |
| osamCntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.15.2.1 | not-accessible | mandatory | |
| osamCntrLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.2.1.15.2.1.1 | CardLocation | read-only | mandatory |
| osamCntrShelf OBJECT-TYPE The shelf number in which the module is plugged in. | 1.3.6.1.4.1.4253.2.1.15.2.1.2 | CardShelf | read-only | mandatory |
| osamCntrSlot OBJECT-TYPE The slot number in which the module is plugged in. | 1.3.6.1.4.1.4253.2.1.15.2.1.3 | INTEGER (1..16) | read-only | mandatory |
| osamCntrKeepAlivePktSent OBJECT-TYPE The total number of keep alive packets sent. | 1.3.6.1.4.1.4253.2.1.15.2.1.4 | Counter | read-only | mandatory |
| osamCntrKeepAlivePktRcvd OBJECT-TYPE The total number of keep alive packets received. | 1.3.6.1.4.1.4253.2.1.15.2.1.5 | Counter | read-only | mandatory |
| osamCntrKeepAliveBadPktRcvd OBJECT-TYPE The total number of bad keep alive data packets received. | 1.3.6.1.4.1.4253.2.1.15.2.1.6 | Counter | read-only | mandatory |
| osamPerfTable OBJECT-TYPE This table represents the information for performance data collected for each osam card | 1.3.6.1.4.1.4253.2.1.15.3 | not-accessible | mandatory | |
| osamPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.15.3.1 | not-accessible | mandatory | |
| osamPerfLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.2.1.15.3.1.1 | CardLocation | read-only | mandatory |
| osamPerfShelf OBJECT-TYPE The shelf number in which the module is plugged in. | 1.3.6.1.4.1.4253.2.1.15.3.1.2 | CardShelf | read-only | mandatory |
| osamPerfSlot OBJECT-TYPE The slot number in which the module is plugged in. | 1.3.6.1.4.1.4253.2.1.15.3.1.3 | INTEGER (1..16) | read-only | mandatory |
| osamPerfState OBJECT-TYPE The current state of the module. | 1.3.6.1.4.1.4253.2.1.15.3.1.4 | CardState | read-only | mandatory |
| osamPerfStatus OBJECT-TYPE The current alarm status of the channel. | 1.3.6.1.4.1.4253.2.1.15.3.1.5 | CardStatus | read-only | mandatory |
| osamPerfLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.1.15.3.1.6 | DateAndTime | read-only | mandatory |
| osamPerfAvailTime OBJECT-TYPE The number of seconds in the most current 15 minutes interval that this module has been up and running. | 1.3.6.1.4.1.4253.2.1.15.3.1.7 | Counter | read-only | mandatory |
| osamPerfErrFreeSecs OBJECT-TYPE The number of seconds in the most current 15 minutes interval that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.15.3.1.8 | Counter | read-only | mandatory |
| osamPerfAprStatus OBJECT-TYPE The status of the automatic power reduction mode. Not applicable to OSAM-HP/LP module | 1.3.6.1.4.1.4253.2.1.15.3.1.9 | FlagType | read-only | mandatory |
| osamPerfInputPower OBJECT-TYPE The power at the input in dBm. Not applicable to OSAM-HP/LP module | 1.3.6.1.4.1.4253.2.1.15.3.1.10 | DisplayString | read-only | mandatory |
| osamPerfBFDPower OBJECT-TYPE The back facet diode reading in the pump laser; related to the power output of the pump laser. This values isn't calibrated and doesn't have a unit. Not applicable to OSAM-HP/LP module | 1.3.6.1.4.1.4253.2.1.15.3.1.11 | DisplayString | read-only | mandatory |
| osamPerfOutputPower OBJECT-TYPE The power at the output port in dBm. | 1.3.6.1.4.1.4253.2.1.15.3.1.12 | DisplayString | read-only | mandatory |
| osamPerfAPRDetector1Power OBJECT-TYPE The automatic power reduction detector 1 reading in dBm. Two readings are provided for redundancy purposes. Not applicable to OSAM-HP/LP module | 1.3.6.1.4.1.4253.2.1.15.3.1.13 | DisplayString | read-only | mandatory |
| osamPerfAPRDetector2Power OBJECT-TYPE The automatic power reduction detector 2 reading in dBm. Two readings are provided for redundancy purposes. Not applicable to OSAM-HP/LP module | 1.3.6.1.4.1.4253.2.1.15.3.1.14 | DisplayString | read-only | mandatory |
| osamPerfLaserTemperature OBJECT-TYPE The pump laser temperature in degree Celsius. Not applicable to OSAM-HP/LP module | 1.3.6.1.4.1.4253.2.1.15.3.1.15 | INTEGER (15..35) | read-only | mandatory |
| osamPerfTecCurrent OBJECT-TYPE The Thermo-Electric Cooler current in mA. Not applicable to OSAM-HP/LP module | 1.3.6.1.4.1.4253.2.1.15.3.1.16 | INTEGER (0..1500) | read-only | mandatory |
| osamPerfBiasCurrent OBJECT-TYPE The measured pump laser bias current in mA. Not applicable to OSAM-HP/LP module | 1.3.6.1.4.1.4253.2.1.15.3.1.17 | INTEGER (0..255) | read-only | mandatory |
| osamPerfAmplifierGain OBJECT-TYPE The measured overall amplifier gain in dB. | 1.3.6.1.4.1.4253.2.1.15.3.1.18 | DisplayString | read-only | mandatory |
| osamPerfPCBTemperature OBJECT-TYPE The temperature of the printed circuit board in degree Celsius. | 1.3.6.1.4.1.4253.2.1.15.3.1.19 | INTEGER (0..75) | read-only | mandatory |
| osam2PerfPump1BFDPower OBJECT-TYPE The back facet diode reading in pump 1 laser; related to the power output of the pump laser. Unit to represent the value is DAC (Digital to Analog converter) | 1.3.6.1.4.1.4253.2.1.15.3.1.20 | INTEGER | read-only | mandatory |
| osam2PerfPump2BFDPower OBJECT-TYPE The back facet diode reading in pump 2 laser; related to the power output of the pump laser. Unit to represent the value is DAC (Digital to Analog converter). Applicable only for OSAM-HP module | 1.3.6.1.4.1.4253.2.1.15.3.1.21 | INTEGER | read-only | mandatory |
| osam2PerfPump1IBias OBJECT-TYPE Indicates the bias current of Pump 1 in mA. The range of values of bias current range from 40 mA - barely turning on, to MaxIbias - maximum operating current recommended by the manufacturer. Pump IBias is used internally to set off alarms and to indicate the health of the module. | 1.3.6.1.4.1.4253.2.1.15.3.1.22 | INTEGER | read-only | mandatory |
| osam2PerfPump2IBias OBJECT-TYPE Indicates the bias current of Pump 2 in mA. The range of values of bias current range from 40 mA - barely turning on, to MaxIbias - maximum operating current recommended by the manufacturer. Pump IBias is used internally to set off alarms and to indicate the health of the module. Applicable only for OSAM-HP module | 1.3.6.1.4.1.4253.2.1.15.3.1.23 | INTEGER | read-only | mandatory |
| osam2PerfPump1ITEC OBJECT-TYPE Indicates the current level in mA of Thermal Electric Cooler (TEC) used for cooling laser pump 1. | 1.3.6.1.4.1.4253.2.1.15.3.1.24 | INTEGER | read-only | mandatory |
| osam2PerfPump2ITEC OBJECT-TYPE Indicates the current level in mA of Thermal Electric Cooler (TEC) used for cooling laser pump 2. Applicable only for OSAM-HP | 1.3.6.1.4.1.4253.2.1.15.3.1.25 | INTEGER | read-only | mandatory |
| osam2PerfPump1Temp OBJECT-TYPE Laser pump (#1) temperature in degree celcius | 1.3.6.1.4.1.4253.2.1.15.3.1.26 | DisplayString | read-only | mandatory |
| osam2PerfPump2Temp OBJECT-TYPE Laser pump (#2) temperature in degree celcius Applicable only for OSAM-HP module | 1.3.6.1.4.1.4253.2.1.15.3.1.27 | DisplayString | read-only | mandatory |
| osam2PerfGBInputPower OBJECT-TYPE Gain block input power in dBm. | 1.3.6.1.4.1.4253.2.1.15.3.1.28 | DisplayString | read-only | mandatory |
| osam2PerfGBOutputPower OBJECT-TYPE Gain block output power in dBm with attenuation set to zero. | 1.3.6.1.4.1.4253.2.1.15.3.1.29 | DisplayString | read-only | mandatory |
| osam2PerfAttenuation OBJECT-TYPE Indicates optical attenuation in dB imposed by variable optical attenuator(VOA) | 1.3.6.1.4.1.4253.2.1.15.3.1.30 | DisplayString | read-only | mandatory |
| rsmPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.16 | |||
| rsmNumEvents OBJECT-TYPE Total number of all traps (events) generated by all RSM's in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.16.1 | Counter | read-only | mandatory |
| rsmPerfTable OBJECT-TYPE This table represents the information for performance data collected for each rsm card | 1.3.6.1.4.1.4253.2.1.16.2 | not-accessible | mandatory | |
| rsmPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.16.2.1 | not-accessible | mandatory | |
| rsmPerfLocation OBJECT-TYPE The location of the card. | 1.3.6.1.4.1.4253.2.1.16.2.1.1 | CardLocation | read-only | mandatory |
| rsmPerfShelf OBJECT-TYPE The shelf the card is in. | 1.3.6.1.4.1.4253.2.1.16.2.1.2 | CardShelf | read-only | mandatory |
| rsmPerfSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.1.16.2.1.3 | CardSlot | read-only | mandatory |
| rsmPerfState OBJECT-TYPE The state of the rsm card. The possible states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.1.16.2.1.4 | CardState | read-only | mandatory |
| rsmPerfStatus OBJECT-TYPE The status of the rsm card. This status represents the status of the rsm card and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.16.2.1.5 | CardStatus | read-only | mandatory |
| rsmLinkAState OBJECT-TYPE The link state of path A (East), whether light is being detected. The states are: linked, notLinked. | 1.3.6.1.4.1.4253.2.1.16.2.1.6 | INTEGER {linked(1), notLinked(2), unknown(3)} | read-only | mandatory |
| rsmLinkAStatus OBJECT-TYPE The status of the card channel. This status represents the status of the link A (East) of the card and in general is different from the status of the card. | 1.3.6.1.4.1.4253.2.1.16.2.1.7 | INTEGER {active(1), standby(2), na(3)} | read-only | mandatory |
| rsmLinkBState OBJECT-TYPE The link state of path B (West), whether light is being detected. The states are: linked, notLinked. | 1.3.6.1.4.1.4253.2.1.16.2.1.8 | INTEGER {linked(1), notLinked(2), unknown(3)} | read-only | mandatory |
| rsmLinkBStatus OBJECT-TYPE The status of the card channel. This status represents the status of the link B (West) of the card and in general is different from the status of the card. | 1.3.6.1.4.1.4253.2.1.16.2.1.9 | INTEGER {active(1), standby(2), na(3)} | read-only | mandatory |
| rsmLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.1.16.2.1.10 | DateAndTime | read-only | mandatory |
| rsmAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this rsm has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.16.2.1.11 | Counter | read-only | mandatory |
| rsmErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this rsm has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.16.2.1.12 | Counter | read-only | mandatory |
| rsmWorkingPower OBJECT-TYPE Working link power of the RSM card in dBm. | 1.3.6.1.4.1.4253.2.1.16.2.1.13 | INTEGER | read-only | mandatory |
| rsmProtectionPower OBJECT-TYPE Protection link power of the RSM card in dBm. | 1.3.6.1.4.1.4253.2.1.16.2.1.14 | INTEGER | read-only | mandatory |
| upsmPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.17 | |||
| upsmNumEvents OBJECT-TYPE Total number of all traps (events) generated by all UPSM's in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.17.1 | Counter | read-only | mandatory |
| upsmPerfTable OBJECT-TYPE This table represents the information for performance data collected for each upsm card | 1.3.6.1.4.1.4253.2.1.17.2 | not-accessible | mandatory | |
| upsmPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.17.2.1 | not-accessible | mandatory | |
| upsmPerfLocation OBJECT-TYPE The location of the card. | 1.3.6.1.4.1.4253.2.1.17.2.1.1 | CardLocation | read-only | mandatory |
| upsmPerfShelf OBJECT-TYPE The shelf the card is in. | 1.3.6.1.4.1.4253.2.1.17.2.1.2 | CardShelf | read-only | mandatory |
| upsmPerfSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.1.17.2.1.3 | CardSlot | read-only | mandatory |
| upsmPerfState OBJECT-TYPE The state of the upsm card. The possible states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.1.17.2.1.4 | CardState | read-only | mandatory |
| upsmPerfStatus OBJECT-TYPE The status of the upsm card. This status represents the status of the upsm card and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.17.2.1.5 | CardStatus | read-only | mandatory |
| upsmLinkAState OBJECT-TYPE The link state of path A (East), whether light is being detected. The states are: linked, notLinked. | 1.3.6.1.4.1.4253.2.1.17.2.1.6 | INTEGER {linked(1), notLinked(2), unknown(3)} | read-only | mandatory |
| upsmLinkAStatus OBJECT-TYPE The status of the card channel. This status represents the status of the link A (East) of the card and in general is different from the status of the card. | 1.3.6.1.4.1.4253.2.1.17.2.1.7 | INTEGER {active(1), standby(2), hibernation(3)} | read-only | mandatory |
| upsmLinkBState OBJECT-TYPE The link state of path B (West), whether light is being detected. The states are: linked, notLinked. | 1.3.6.1.4.1.4253.2.1.17.2.1.8 | INTEGER {linked(1), notLinked(2), unknown(3)} | read-only | mandatory |
| upsmLinkBStatus OBJECT-TYPE The status of the card channel. This status represents the status of the link B (West) of the card and in general is different from the status of the card. | 1.3.6.1.4.1.4253.2.1.17.2.1.9 | INTEGER {active(1), standby(2), hibernation(3)} | read-only | mandatory |
| upsmLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.1.17.2.1.10 | DateAndTime | read-only | mandatory |
| upsmAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this upsm has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.17.2.1.11 | Counter | read-only | mandatory |
| upsmErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this upsm has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.17.2.1.12 | Counter | read-only | mandatory |
| upsmWorkingPower OBJECT-TYPE Working link power of the UPSM card in dBm. | 1.3.6.1.4.1.4253.2.1.17.2.1.13 | INTEGER | read-only | mandatory |
| upsmProtectionPower OBJECT-TYPE Protection link power of the UPSM card in dBm. | 1.3.6.1.4.1.4253.2.1.17.2.1.14 | INTEGER | read-only | mandatory |
| mcmescPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.18 | |||
| mcmescNumEvents OBJECT-TYPE Total number of events received for all mcmesc's in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.18.1 | Counter | read-only | mandatory |
| mcmescCntrTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.1.18.2 | not-accessible | mandatory | |
| mcmescCntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.18.2.1 | not-accessible | mandatory | |
| mcmescCntrLocation OBJECT-TYPE The location of the mcmesc card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmesc cards. | 1.3.6.1.4.1.4253.2.1.18.2.1.1 | CardLocation | read-only | mandatory |
| mcmescCntrShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmesc cards. | 1.3.6.1.4.1.4253.2.1.18.2.1.2 | CardShelf | read-only | mandatory |
| mcmescCntrSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 21. The system automatically determines the right value for this entry based on the known (available) mcmesc cards. | 1.3.6.1.4.1.4253.2.1.18.2.1.3 | CardSlot | read-only | mandatory |
| mcmescCntrType OBJECT-TYPE The type of the software counter data in this row. The data is collected for the SPI data channels. | 1.3.6.1.4.1.4253.2.1.18.2.1.4 | INTEGER {spi(1), iwm(2)} | read-only | mandatory |
| mcmescCounterFlag OBJECT-TYPE Turns software counters On or Off for this mcmesc. | 1.3.6.1.4.1.4253.2.1.18.2.1.5 | FlagType | read-write | mandatory |
| mcmescTotPktSent OBJECT-TYPE The number of data packets sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.18.2.1.6 | Counter | read-only | mandatory |
| mcmescTotPktRcvd OBJECT-TYPE The number of data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.18.2.1.7 | Counter | read-only | mandatory |
| mcmescBadPktRcvd OBJECT-TYPE The number of bad data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.18.2.1.8 | Counter | read-only | mandatory |
| mcmescTotBadTrans OBJECT-TYPE The number of bad data transmissions over the given data channel. | 1.3.6.1.4.1.4253.2.1.18.2.1.9 | Counter | read-only | mandatory |
| mcmescBytesSent OBJECT-TYPE Total number of bytes sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.18.2.1.10 | Counter | read-only | mandatory |
| mcmescBytesRcvd OBJECT-TYPE Total number of data bytes received over the given data channel. | 1.3.6.1.4.1.4253.2.1.18.2.1.11 | Counter | read-only | mandatory |
| mcmescMsgsDlvrd OBJECT-TYPE The number of complete messages delivered over the given data channel. | 1.3.6.1.4.1.4253.2.1.18.2.1.12 | Counter | read-only | mandatory |
| mcmescClearCntrs OBJECT-TYPE If the value is reset, all software counters are reset to zero. A get on this will always return other | 1.3.6.1.4.1.4253.2.1.18.2.1.13 | ResetType | read-write | mandatory |
| mcmescPerfTable OBJECT-TYPE This table represents the information for performance data collected for each mcmesc card | 1.3.6.1.4.1.4253.2.1.18.3 | not-accessible | mandatory | |
| mcmescPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.18.3.1 | not-accessible | mandatory | |
| mcmescPerfLocation OBJECT-TYPE The location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) mcmesc cards. | 1.3.6.1.4.1.4253.2.1.18.3.1.1 | CardLocation | read-only | mandatory |
| mcmescPerfShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 3 | 1.3.6.1.4.1.4253.2.1.18.3.1.2 | CardShelf | read-only | mandatory |
| mcmescPerfSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 21 | 1.3.6.1.4.1.4253.2.1.18.3.1.3 | CardSlot | read-only | mandatory |
| mcmescPerfState OBJECT-TYPE The state of the mcmesc card. The states' are: online, offline, empty, loopback or diagnostics. | 1.3.6.1.4.1.4253.2.1.18.3.1.4 | CardState | read-only | mandatory |
| mcmescPerfStatus OBJECT-TYPE The status of the channel card. This status represents the status of the communication processor and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.18.3.1.5 | CardStatus | read-only | mandatory |
| mcmescLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.1.18.3.1.6 | DateAndTime | read-only | mandatory |
| mcmescAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this mcmesc has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.18.3.1.7 | Counter | read-only | mandatory |
| mcmescPortCurrTable OBJECT-TYPE This table represents the information for each mcmesc cpe port's current counters. | 1.3.6.1.4.1.4253.2.1.18.4 | not-accessible | mandatory | |
| mcmescPortCurrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.18.4.1 | not-accessible | mandatory | |
| mcmescPortCurrCardLocation OBJECT-TYPE Location of the MCMESC CPE port. Valid values are: Local in the same chassis, or remote to this chassis | 1.3.6.1.4.1.4253.2.1.18.4.1.1 | CardLocation | read-only | mandatory |
| mcmescPortCurrCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 2..3. | 1.3.6.1.4.1.4253.2.1.18.4.1.2 | CardShelf | read-only | mandatory |
| mcmescPortCurrCardSlot OBJECT-TYPE The slot within the shelf the Module is in. | 1.3.6.1.4.1.4253.2.1.18.4.1.3 | CardSlot | read-only | mandatory |
| mcmescPortCurrPort OBJECT-TYPE CPE port's index. | 1.3.6.1.4.1.4253.2.1.18.4.1.4 | INTEGER | read-only | mandatory |
| mcmescPortCurrRxSig OBJECT-TYPE CPE port's receive signal power. | 1.3.6.1.4.1.4253.2.1.18.4.1.5 | DisplayString (SIZE(0..10)) | read-only | mandatory |
| mcmescPortCurrDuration OBJECT-TYPE mcmesc CPE port's current ongoing interval duration. | 1.3.6.1.4.1.4253.2.1.18.4.1.6 | DisplayString | read-only | mandatory |
| mcmescPortCurrEns OBJECT-TYPE mcmesc CPE port's enabled seconds during current ongoing interval. | 1.3.6.1.4.1.4253.2.1.18.4.1.7 | DisplayString | read-only | mandatory |
| mcmescPortCurrLoss OBJECT-TYPE mcmesc CPE port's loss of signal seconds during current ongoing interval. | 1.3.6.1.4.1.4253.2.1.18.4.1.8 | DisplayString | read-only | mandatory |
| mcmescPortCurrCrcErr OBJECT-TYPE mcmesc CPE port's CRC error counter during current ongoing interval. | 1.3.6.1.4.1.4253.2.1.18.4.1.9 | DisplayString | read-only | mandatory |
| mcmescPortCurrOobErr OBJECT-TYPE mcmesc CPE port's Out-Of_Band error counter during current ongoing interval. | 1.3.6.1.4.1.4253.2.1.18.4.1.10 | DisplayString | read-only | mandatory |
| mcmescPortCurrRdpErr OBJECT-TYPE mcmesc CPE port's Running Disparity error counter during current ongoing interval. | 1.3.6.1.4.1.4253.2.1.18.4.1.11 | DisplayString | read-only | mandatory |
| mcmescPortCurrBer OBJECT-TYPE mcmesc CPE port's BER, in the form of x.yE-z. | 1.3.6.1.4.1.4253.2.1.18.4.1.12 | DisplayString | read-only | mandatory |
| mcmescLinkCurrTable OBJECT-TYPE This table represents the information for each mcmesc cpe port's current counters. | 1.3.6.1.4.1.4253.2.1.18.5 | not-accessible | mandatory | |
| mcmescLinkCurrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.18.5.1 | not-accessible | mandatory | |
| mcmescLinkCurrCardLocation OBJECT-TYPE Location of the MCMESC CPE port. Valid values are: Local in the same chassis, or remote to this chassis | 1.3.6.1.4.1.4253.2.1.18.5.1.1 | CardLocation | read-only | mandatory |
| mcmescLinkCurrCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 2..3. | 1.3.6.1.4.1.4253.2.1.18.5.1.2 | CardShelf | read-only | mandatory |
| mcmescLinkCurrCardSlot OBJECT-TYPE The slot within the shelf the Module is in. | 1.3.6.1.4.1.4253.2.1.18.5.1.3 | CardSlot | read-only | mandatory |
| mcmescLinkCurrRxSig OBJECT-TYPE Link port's receive signal power. | 1.3.6.1.4.1.4253.2.1.18.5.1.4 | DisplayString (SIZE(0..10)) | read-only | mandatory |
| mcmescLinkCurrDuration OBJECT-TYPE mcmesc LINK port's current ongoing interval duration. | 1.3.6.1.4.1.4253.2.1.18.5.1.5 | DisplayString | read-only | mandatory |
| mcmescLinkCurrTsos OBJECT-TYPE mcmesc LINK port's test-sequence on seconds during current ongoing interval. | 1.3.6.1.4.1.4253.2.1.18.5.1.6 | DisplayString | read-only | mandatory |
| mcmescLinkCurrLoss OBJECT-TYPE mcmesc LINK port's loss of signal seconds during current ongoing interval. | 1.3.6.1.4.1.4253.2.1.18.5.1.7 | DisplayString | read-only | mandatory |
| mcmescLinkCurrCrcErr OBJECT-TYPE mcmesc LINK port's CRC error counter during current ongoing interval. | 1.3.6.1.4.1.4253.2.1.18.5.1.8 | DisplayString | read-only | mandatory |
| mcmescLinkCurrOobErr OBJECT-TYPE mcmesc LINK port's Out-Of_Band error counter during current ongoing interval. | 1.3.6.1.4.1.4253.2.1.18.5.1.9 | DisplayString | read-only | mandatory |
| mcmescLinkCurrRdpErr OBJECT-TYPE mcmesc LINK port's Running Disparity error counter during current ongoing interval. | 1.3.6.1.4.1.4253.2.1.18.5.1.10 | DisplayString | read-only | mandatory |
| mcmescLinkCurrBer OBJECT-TYPE mcmesc LINK port's BER, in the form of x.yE-z. | 1.3.6.1.4.1.4253.2.1.18.5.1.11 | DisplayString | read-only | mandatory |
| routingPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.21 | |||
| imnRoutingPerfTable OBJECT-TYPE This table represents the information for performance data collected for each route | 1.3.6.1.4.1.4253.2.1.21.1 | not-accessible | mandatory | |
| imnRoutingPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.21.1.1 | not-accessible | mandatory | |
| imnRoutePerfIpDest OBJECT-TYPE Destination IP address. Not supported for remote TMM masters. | 1.3.6.1.4.1.4253.2.1.21.1.1.1 | IpAddress | read-only | mandatory |
| imnRoutePerfStatus OBJECT-TYPE Is the route active, comatose or dead | 1.3.6.1.4.1.4253.2.1.21.1.1.2 | INTEGER {dead(1), comatose(2), active(3)} | read-only | mandatory |
| tapPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.22 | |||
| tapNumEvents OBJECT-TYPE Total number of all traps (events) generated by all TAP modules in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.22.1 | Counter | read-only | mandatory |
| tapPerfTable OBJECT-TYPE This table represents the information for performance data collected for each TAP module. | 1.3.6.1.4.1.4253.2.1.22.2 | not-accessible | mandatory | |
| tapPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.22.2.1 | not-accessible | mandatory | |
| tapPerfLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.1.22.2.1.1 | CardLocation | read-only | mandatory |
| tapPerfShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.1.22.2.1.2 | CardShelf | read-only | mandatory |
| tapPerfSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.1.22.2.1.3 | CardSlot | read-only | mandatory |
| tapType OBJECT-TYPE Module type. | 1.3.6.1.4.1.4253.2.1.22.2.1.4 | CardType | read-only | mandatory |
| tapPerfState OBJECT-TYPE The state of the TAP module. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.1.22.2.1.5 | CardState | read-only | mandatory |
| tapPerfStatus OBJECT-TYPE The status of the TAP module. This status represents the status of the TAP module and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.22.2.1.6 | CardStatus | read-only | mandatory |
| tapLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.1.22.2.1.7 | DateAndTime | read-only | mandatory |
| tapAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.22.2.1.8 | Counter | read-only | mandatory |
| tapErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.22.2.1.9 | Counter | read-only | mandatory |
| voadmPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.23 | |||
| voadmNumEvents OBJECT-TYPE Total number of all traps (events) generated by all VOADM modules in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.23.1 | Counter | read-only | mandatory |
| voadmPerfTable OBJECT-TYPE This table represents the information for performance data collected for each VOADM module. | 1.3.6.1.4.1.4253.2.1.23.2 | not-accessible | mandatory | |
| voadmPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.23.2.1 | not-accessible | mandatory | |
| voadmPerfLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.1.23.2.1.1 | CardLocation | read-only | mandatory |
| voadmPerfShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.1.23.2.1.2 | CardShelf | read-only | mandatory |
| voadmPerfSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.1.23.2.1.3 | CardSlot | read-only | mandatory |
| voadmType OBJECT-TYPE Module type. | 1.3.6.1.4.1.4253.2.1.23.2.1.4 | CardType | read-only | mandatory |
| voadmPerfState OBJECT-TYPE The state of the VOADM module. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.1.23.2.1.5 | CardState | read-only | mandatory |
| voadmPerfStatus OBJECT-TYPE The status of the VOADM module. This status represents the status of the VOADM module and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.23.2.1.6 | CardStatus | read-only | mandatory |
| voadmLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.1.23.2.1.7 | DateAndTime | read-only | mandatory |
| voadmAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.23.2.1.8 | Counter | read-only | mandatory |
| voadmErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.23.2.1.9 | Counter | read-only | mandatory |
| dmmPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.24 | |||
| dmmNumEvents OBJECT-TYPE Total number of all traps (events) generated by all DMM modules in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.24.1 | Counter | read-only | mandatory |
| dmmPerfTable OBJECT-TYPE This table represents the information for performance data collected for each DMM module. | 1.3.6.1.4.1.4253.2.1.24.2 | not-accessible | mandatory | |
| dmmPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.24.2.1 | not-accessible | mandatory | |
| dmmPerfLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.1.24.2.1.1 | CardLocation | read-only | mandatory |
| dmmPerfShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.1.24.2.1.2 | CardShelf | read-only | mandatory |
| dmmPerfSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.1.24.2.1.3 | CardSlot | read-only | mandatory |
| dmmPerfState OBJECT-TYPE The state of the DMM module. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.1.24.2.1.4 | CardState | read-only | mandatory |
| dmmPerfStatus OBJECT-TYPE The status of the DMM module. This status represents the status of the DMM module and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.24.2.1.5 | CardStatus | read-only | mandatory |
| dmmLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.1.24.2.1.6 | DateAndTime | read-only | mandatory |
| dmmAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.24.2.1.7 | Counter | read-only | mandatory |
| dmmErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.24.2.1.8 | Counter | read-only | mandatory |
| dmmCntrTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.1.24.3 | not-accessible | mandatory | |
| dmmCntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.24.3.1 | not-accessible | mandatory | |
| dmmCntrLocation OBJECT-TYPE The location of the DMM card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known DMM cards. | 1.3.6.1.4.1.4253.2.1.24.3.1.1 | CardLocation | read-only | mandatory |
| dmmCntrShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) DMM cards. | 1.3.6.1.4.1.4253.2.1.24.3.1.2 | CardShelf | read-only | mandatory |
| dmmCntrSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) DMM cards. | 1.3.6.1.4.1.4253.2.1.24.3.1.3 | CardSlot | read-only | mandatory |
| dmmCntrType OBJECT-TYPE The type of the software counter data in this row. | 1.3.6.1.4.1.4253.2.1.24.3.1.4 | INTEGER {spi(1), ibm(2), hdlc(3)} | read-only | mandatory |
| dmmTotPktSent OBJECT-TYPE The number of data packets sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.24.3.1.5 | Counter | read-only | mandatory |
| dmmTotPktRcvd OBJECT-TYPE The number of data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.24.3.1.6 | Counter | read-only | mandatory |
| dmmTotBadTrans OBJECT-TYPE The number of bad data transmissions over the given data channel. | 1.3.6.1.4.1.4253.2.1.24.3.1.7 | Counter | read-only | mandatory |
| dmmBadPktRcvd OBJECT-TYPE The number of bad data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.24.3.1.8 | Counter | read-only | mandatory |
| dmmBytesSent OBJECT-TYPE Total number of bytes sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.24.3.1.9 | Counter | read-only | mandatory |
| dmmBytesRcvd OBJECT-TYPE Total number of data bytes received over the given data channel. | 1.3.6.1.4.1.4253.2.1.24.3.1.10 | Counter | read-only | mandatory |
| dmmMsgsDlvrd OBJECT-TYPE The number of complete messages delivered over the given data channel. | 1.3.6.1.4.1.4253.2.1.24.3.1.11 | Counter | read-only | mandatory |
| dmmClearCntrs OBJECT-TYPE If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other | 1.3.6.1.4.1.4253.2.1.24.3.1.12 | ResetType | read-write | mandatory |
| dmmPmTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.1.24.4 | not-accessible | mandatory | |
| dmmPmEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.24.4.1 | not-accessible | mandatory | |
| dmmPmLocation OBJECT-TYPE The location of the DMM card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known DMM cards. | 1.3.6.1.4.1.4253.2.1.24.4.1.1 | CardLocation | read-only | mandatory |
| dmmPmShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) DMM cards. | 1.3.6.1.4.1.4253.2.1.24.4.1.2 | CardShelf | read-only | mandatory |
| dmmPmSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) DMM cards. | 1.3.6.1.4.1.4253.2.1.24.4.1.3 | CardSlot | read-only | mandatory |
| dmmPmType OBJECT-TYPE The type of the software counter data in this row. | 1.3.6.1.4.1.4253.2.1.24.4.1.4 | INTEGER {link(1), port1(2), port2(3)} | read-only | mandatory |
| dmmPmErrors OBJECT-TYPE The number of packets errors since port last came online. | 1.3.6.1.4.1.4253.2.1.24.4.1.5 | Counter | read-only | mandatory |
| dmmPmErredSecs OBJECT-TYPE The number of erred seconds since port last came online. | 1.3.6.1.4.1.4253.2.1.24.4.1.6 | Counter | read-only | mandatory |
| dmmStartTime OBJECT-TYPE The date/time the port came last online. | 1.3.6.1.4.1.4253.2.1.24.4.1.7 | DateAndTime | read-only | mandatory |
| dmmClearPmCntrs OBJECT-TYPE If the value is reset, all PM counters for this port are reset to zero. A get on this will always return other | 1.3.6.1.4.1.4253.2.1.24.4.1.8 | ResetType | read-write | mandatory |
| dmmPmRxPower OBJECT-TYPE Port receive power. | 1.3.6.1.4.1.4253.2.1.24.4.1.9 | DisplayString | read-only | mandatory |
| dmmPmTxPower OBJECT-TYPE Port receive power. | 1.3.6.1.4.1.4253.2.1.24.4.1.10 | DisplayString | read-only | mandatory |
| ocm10gfPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.25 | |||
| ocm10gfNumEvents OBJECT-TYPE Total number of all traps (events) generated by all OCM10GF modules in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.25.1 | Counter | read-only | mandatory |
| ocm10gfPerfTable OBJECT-TYPE This table represents the information for performance data collected for each OCM10GF module. | 1.3.6.1.4.1.4253.2.1.25.2 | not-accessible | mandatory | |
| ocm10gfPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.25.2.1 | not-accessible | mandatory | |
| ocm10gfPerfLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.1.25.2.1.1 | CardLocation | read-only | mandatory |
| ocm10gfPerfShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.1.25.2.1.2 | CardShelf | read-only | mandatory |
| ocm10gfPerfSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.1.25.2.1.3 | CardSlot | read-only | mandatory |
| ocm10gfPerfState OBJECT-TYPE The state of the OCM10GF module. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.1.25.2.1.4 | CardState | read-only | mandatory |
| ocm10gfPerfStatus OBJECT-TYPE The status of the OCM10GF module. This status represents the status of the OCM10GF module and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.25.2.1.5 | CardStatus | read-only | mandatory |
| ocm10gfLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.1.25.2.1.6 | DateAndTime | read-only | mandatory |
| ocm10gfAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.25.2.1.7 | Counter | read-only | mandatory |
| ocm10gfErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.25.2.1.8 | Counter | read-only | mandatory |
| ocm10gfCntrTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.1.25.3 | not-accessible | mandatory | |
| ocm10gfCntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.25.3.1 | not-accessible | mandatory | |
| ocm10gfCntrLocation OBJECT-TYPE The location of the OCM10GF card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM10GF cards. | 1.3.6.1.4.1.4253.2.1.25.3.1.1 | CardLocation | read-only | mandatory |
| ocm10gfCntrShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM10GF cards. | 1.3.6.1.4.1.4253.2.1.25.3.1.2 | CardShelf | read-only | mandatory |
| ocm10gfCntrSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM10GF cards. | 1.3.6.1.4.1.4253.2.1.25.3.1.3 | CardSlot | read-only | mandatory |
| ocm10gfCntrType OBJECT-TYPE The type of the software counter data in this row. | 1.3.6.1.4.1.4253.2.1.25.3.1.4 | INTEGER {spi(1), ibm(2), hdlc(3)} | read-only | mandatory |
| ocm10gfTotPktSent OBJECT-TYPE The number of data packets sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.25.3.1.5 | Counter | read-only | mandatory |
| ocm10gfTotPktRcvd OBJECT-TYPE The number of data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.25.3.1.6 | Counter | read-only | mandatory |
| ocm10gfTotBadTrans OBJECT-TYPE The number of bad data transmissions over the given data channel. | 1.3.6.1.4.1.4253.2.1.25.3.1.7 | Counter | read-only | mandatory |
| ocm10gfBadPktRcvd OBJECT-TYPE The number of bad data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.25.3.1.8 | Counter | read-only | mandatory |
| ocm10gfBytesSent OBJECT-TYPE Total number of bytes sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.25.3.1.9 | Counter | read-only | mandatory |
| ocm10gfBytesRcvd OBJECT-TYPE Total number of data bytes received over the given data channel. | 1.3.6.1.4.1.4253.2.1.25.3.1.10 | Counter | read-only | mandatory |
| ocm10gfMsgsDlvrd OBJECT-TYPE The number of complete messages delivered over the given data channel. | 1.3.6.1.4.1.4253.2.1.25.3.1.11 | Counter | read-only | mandatory |
| ocm10gfClearCntrs OBJECT-TYPE If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other | 1.3.6.1.4.1.4253.2.1.25.3.1.12 | ResetType | read-write | mandatory |
| ocm10gfPmTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.1.25.4 | not-accessible | mandatory | |
| ocm10gfPmEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.25.4.1 | not-accessible | mandatory | |
| ocm10gfPmLocation OBJECT-TYPE The location of the OCM10GF card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM10GF cards. | 1.3.6.1.4.1.4253.2.1.25.4.1.1 | CardLocation | read-only | mandatory |
| ocm10gfPmShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM10GF cards. | 1.3.6.1.4.1.4253.2.1.25.4.1.2 | CardShelf | read-only | mandatory |
| ocm10gfPmSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM10GF cards. | 1.3.6.1.4.1.4253.2.1.25.4.1.3 | CardSlot | read-only | mandatory |
| ocm10gfPmNumIntervals OBJECT-TYPE | 1.3.6.1.4.1.4253.2.1.25.4.1.4 | INTEGER | read-only | mandatory |
| ocm10gfPmLinkRxPwr OBJECT-TYPE | 1.3.6.1.4.1.4253.2.1.25.4.1.5 | DisplayString | read-only | mandatory |
| ocm10gfPmLinkTxPwr OBJECT-TYPE | 1.3.6.1.4.1.4253.2.1.25.4.1.6 | DisplayString | read-only | mandatory |
| ocm10gfPmLinkFecErrors OBJECT-TYPE | 1.3.6.1.4.1.4253.2.1.25.4.1.7 | DisplayString | read-only | mandatory |
| ocm10gfPmLinkUncorrectedFecErrs OBJECT-TYPE | 1.3.6.1.4.1.4253.2.1.25.4.1.8 | Counter | read-only | mandatory |
| ocm10gfPmLinkCorrectedFecErrs OBJECT-TYPE | 1.3.6.1.4.1.4253.2.1.25.4.1.9 | DisplayString | read-only | mandatory |
| ocm10gfPmLinkCorrectedOnesErr OBJECT-TYPE | 1.3.6.1.4.1.4253.2.1.25.4.1.10 | DisplayString | read-only | mandatory |
| ocm10gfPmLinkErredSeconds OBJECT-TYPE | 1.3.6.1.4.1.4253.2.1.25.4.1.11 | Counter | read-only | mandatory |
| ocm10gfPmCpeRxPwr OBJECT-TYPE | 1.3.6.1.4.1.4253.2.1.25.4.1.12 | DisplayString | read-only | mandatory |
| ocm10gfPmCpeTxPwr OBJECT-TYPE | 1.3.6.1.4.1.4253.2.1.25.4.1.13 | DisplayString | read-only | mandatory |
| ocm10gfPmCpeSonetRxB2Errs OBJECT-TYPE | 1.3.6.1.4.1.4253.2.1.25.4.1.14 | DisplayString | read-only | mandatory |
| ocm10gfPmCpeSonetTxB2Errs OBJECT-TYPE | 1.3.6.1.4.1.4253.2.1.25.4.1.15 | DisplayString | read-only | mandatory |
| ocm10gfPmCpe10GbeRxTotalPkts OBJECT-TYPE | 1.3.6.1.4.1.4253.2.1.25.4.1.16 | DisplayString | read-only | mandatory |
| ocm10gfPmCpe10GbeRxErredPkts OBJECT-TYPE | 1.3.6.1.4.1.4253.2.1.25.4.1.17 | DisplayString | read-only | mandatory |
| ocm10gfPmCpe10GbeTxTotalPkts OBJECT-TYPE | 1.3.6.1.4.1.4253.2.1.25.4.1.18 | DisplayString | read-only | mandatory |
| ocm10gfPmCpe10gbeTxErredPkts OBJECT-TYPE | 1.3.6.1.4.1.4253.2.1.25.4.1.19 | DisplayString | read-only | mandatory |
| ocm10gfPmCpeErredSeconds OBJECT-TYPE | 1.3.6.1.4.1.4253.2.1.25.4.1.20 | Counter | read-only | mandatory |
| ocm10gfClearPmCntrs OBJECT-TYPE If the value is reset, all PM counters for this port are reset to zero. A get on this will always return other | 1.3.6.1.4.1.4253.2.1.25.4.1.21 | ResetType | read-write | mandatory |
| ocm2Perf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.26 | |||
| ocm2NumEvents OBJECT-TYPE Total number of all traps (events) generated by all OCM2 modules in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.26.1 | Counter | read-only | mandatory |
| ocm2PerfTable OBJECT-TYPE This table represents the information for performance data collected for each OCM2 module. | 1.3.6.1.4.1.4253.2.1.26.2 | not-accessible | mandatory | |
| ocm2PerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.26.2.1 | not-accessible | mandatory | |
| ocm2PerfLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.1.26.2.1.1 | CardLocation | read-only | mandatory |
| ocm2PerfShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.1.26.2.1.2 | CardShelf | read-only | mandatory |
| ocm2PerfSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.1.26.2.1.3 | CardSlot | read-only | mandatory |
| ocm2PerfState OBJECT-TYPE The state of the OCM2 module. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.1.26.2.1.4 | CardState | read-only | mandatory |
| ocm2PerfStatus OBJECT-TYPE The status of the OCM2 module. This status represents the status of the OCM2 module and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.26.2.1.5 | CardStatus | read-only | mandatory |
| ocm2LastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.1.26.2.1.6 | DateAndTime | read-only | mandatory |
| ocm2AvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.26.2.1.7 | Counter | read-only | mandatory |
| ocm2ErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.26.2.1.8 | Counter | read-only | mandatory |
| ocm2CntrTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.1.26.3 | not-accessible | mandatory | |
| ocm2CntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.26.3.1 | not-accessible | mandatory | |
| ocm2CntrLocation OBJECT-TYPE The location of the OCM2 card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM2 cards. | 1.3.6.1.4.1.4253.2.1.26.3.1.1 | CardLocation | read-only | mandatory |
| ocm2CntrShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM2 cards. | 1.3.6.1.4.1.4253.2.1.26.3.1.2 | CardShelf | read-only | mandatory |
| ocm2CntrSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM2 cards. | 1.3.6.1.4.1.4253.2.1.26.3.1.3 | CardSlot | read-only | mandatory |
| ocm2CntrType OBJECT-TYPE The type of the software counter data in this row. | 1.3.6.1.4.1.4253.2.1.26.3.1.4 | INTEGER {spi(1), ibm1(2), ibm2(3), hdlc(4)} | read-only | mandatory |
| ocm2TotPktSent OBJECT-TYPE The number of data packets sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.26.3.1.5 | Counter | read-only | mandatory |
| ocm2TotPktRcvd OBJECT-TYPE The number of data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.26.3.1.6 | Counter | read-only | mandatory |
| ocm2TotBadTrans OBJECT-TYPE The number of bad data transmissions over the given data channel. | 1.3.6.1.4.1.4253.2.1.26.3.1.7 | Counter | read-only | mandatory |
| ocm2BadPktRcvd OBJECT-TYPE The number of bad data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.26.3.1.8 | Counter | read-only | mandatory |
| ocm2BytesSent OBJECT-TYPE Total number of bytes sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.26.3.1.9 | Counter | read-only | mandatory |
| ocm2BytesRcvd OBJECT-TYPE Total number of data bytes received over the given data channel. | 1.3.6.1.4.1.4253.2.1.26.3.1.10 | Counter | read-only | mandatory |
| ocm2MsgsDlvrd OBJECT-TYPE The number of complete messages delivered over the given data channel. | 1.3.6.1.4.1.4253.2.1.26.3.1.11 | Counter | read-only | mandatory |
| ocm2ClearCntrs OBJECT-TYPE If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other | 1.3.6.1.4.1.4253.2.1.26.3.1.12 | ResetType | read-write | mandatory |
| ocm2PmTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.1.26.4 | not-accessible | mandatory | |
| ocm2PmEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.26.4.1 | not-accessible | mandatory | |
| ocm2PmLocation OBJECT-TYPE The location of the OCM2 card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM2 cards. | 1.3.6.1.4.1.4253.2.1.26.4.1.1 | CardLocation | read-only | mandatory |
| ocm2PmShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM2 cards. | 1.3.6.1.4.1.4253.2.1.26.4.1.2 | CardShelf | read-only | mandatory |
| ocm2PmSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM2 cards. | 1.3.6.1.4.1.4253.2.1.26.4.1.3 | CardSlot | read-only | mandatory |
| ocm2PmLink OBJECT-TYPE The link for which statistics are for. | 1.3.6.1.4.1.4253.2.1.26.4.1.4 | INTEGER {link1(1), link2(2)} | read-only | mandatory |
| ocm2PmLinkRxPwr OBJECT-TYPE Link receive power. | 1.3.6.1.4.1.4253.2.1.26.4.1.5 | DisplayString | read-only | mandatory |
| ocm2PmLinkTxPwr OBJECT-TYPE Link transmit power. | 1.3.6.1.4.1.4253.2.1.26.4.1.6 | DisplayString | read-only | mandatory |
| ocm2PmCpeRxPwr OBJECT-TYPE CPE receive power. | 1.3.6.1.4.1.4253.2.1.26.4.1.7 | DisplayString | read-only | mandatory |
| ocm2PmCpeTxPwr OBJECT-TYPE CPE transmit power. | 1.3.6.1.4.1.4253.2.1.26.4.1.8 | DisplayString | read-only | mandatory |
| ocm2PmNumLinkRxIntervals OBJECT-TYPE The of intervals (seconds) over which the link Rx statistics have been accumulated. | 1.3.6.1.4.1.4253.2.1.26.4.1.9 | INTEGER | read-only | mandatory |
| ocm2PmLinkRxErrors OBJECT-TYPE Link receive errors. | 1.3.6.1.4.1.4253.2.1.26.4.1.10 | DisplayString | read-only | mandatory |
| ocm2PmLinkRxErredSeconds OBJECT-TYPE Link receive errored seconds. | 1.3.6.1.4.1.4253.2.1.26.4.1.11 | Counter | read-only | mandatory |
| ocm2PmNumCpeRxIntervals OBJECT-TYPE The of intervals (seconds) over which the CPE Rx statistics have been accumulated. | 1.3.6.1.4.1.4253.2.1.26.4.1.12 | INTEGER | read-only | mandatory |
| ocm2PmCpeRxErrors OBJECT-TYPE CPE receive errors. | 1.3.6.1.4.1.4253.2.1.26.4.1.13 | DisplayString | read-only | mandatory |
| ocm2PmCpeRxErredSeconds OBJECT-TYPE CPE receive errored seconds. | 1.3.6.1.4.1.4253.2.1.26.4.1.14 | Counter | read-only | mandatory |
| ocm2PmNumCpeTxIntervals OBJECT-TYPE The of intervals (seconds) over which the CPE Tx statistics have been accumulated. | 1.3.6.1.4.1.4253.2.1.26.4.1.15 | INTEGER | read-only | mandatory |
| ocm2PmCpeTxErrors OBJECT-TYPE CPE transmit errors. | 1.3.6.1.4.1.4253.2.1.26.4.1.16 | DisplayString | read-only | mandatory |
| ocm2PmCpeTxErredSeconds OBJECT-TYPE CPE transmit errored seconds. | 1.3.6.1.4.1.4253.2.1.26.4.1.17 | Counter | read-only | mandatory |
| ocm2ClearPmCntrs OBJECT-TYPE If the value is reset, all PM counters for this port are reset to zero. A get on this will always return other | 1.3.6.1.4.1.4253.2.1.26.4.1.18 | ResetType | read-write | mandatory |
| oscPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.27 | |||
| oscNumEvents OBJECT-TYPE Total number of all traps (events) generated by all OSC modules in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.27.1 | Counter | read-only | mandatory |
| oscPerfTable OBJECT-TYPE This table represents the information for performance data collected for each OSC module. | 1.3.6.1.4.1.4253.2.1.27.2 | not-accessible | mandatory | |
| oscPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.27.2.1 | not-accessible | mandatory | |
| oscPerfLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.1.27.2.1.1 | CardLocation | read-only | mandatory |
| oscPerfShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.1.27.2.1.2 | CardShelf | read-only | mandatory |
| oscPerfSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.1.27.2.1.3 | CardSlot | read-only | mandatory |
| oscPerfState OBJECT-TYPE The state of the OSC module. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.1.27.2.1.4 | CardState | read-only | mandatory |
| oscPerfStatus OBJECT-TYPE The status of the OSC module. This status represents the status of the OSC module and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.27.2.1.5 | CardStatus | read-only | mandatory |
| oscLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.1.27.2.1.6 | DateAndTime | read-only | mandatory |
| oscAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.27.2.1.7 | Counter | read-only | mandatory |
| oscErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.27.2.1.8 | Counter | read-only | mandatory |
| oscCntrTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.1.27.3 | not-accessible | mandatory | |
| oscCntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.27.3.1 | not-accessible | mandatory | |
| oscCntrLocation OBJECT-TYPE The location of the OSC card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OSC cards. | 1.3.6.1.4.1.4253.2.1.27.3.1.1 | CardLocation | read-only | mandatory |
| oscCntrShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OSC cards. | 1.3.6.1.4.1.4253.2.1.27.3.1.2 | CardShelf | read-only | mandatory |
| oscCntrSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OSC cards. | 1.3.6.1.4.1.4253.2.1.27.3.1.3 | CardSlot | read-only | mandatory |
| oscCntrType OBJECT-TYPE The type of the software counter data in this row. | 1.3.6.1.4.1.4253.2.1.27.3.1.4 | INTEGER {spi(1), ibm(2), hdlc(3)} | read-only | mandatory |
| oscTotPktSent OBJECT-TYPE The number of data packets sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.27.3.1.5 | Counter | read-only | mandatory |
| oscTotPktRcvd OBJECT-TYPE The number of data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.27.3.1.6 | Counter | read-only | mandatory |
| oscTotBadTrans OBJECT-TYPE The number of bad data transmissions over the given data channel. | 1.3.6.1.4.1.4253.2.1.27.3.1.7 | Counter | read-only | mandatory |
| oscBadPktRcvd OBJECT-TYPE The number of bad data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.27.3.1.8 | Counter | read-only | mandatory |
| oscBytesSent OBJECT-TYPE Total number of bytes sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.27.3.1.9 | Counter | read-only | mandatory |
| oscBytesRcvd OBJECT-TYPE Total number of data bytes received over the given data channel. | 1.3.6.1.4.1.4253.2.1.27.3.1.10 | Counter | read-only | mandatory |
| oscMsgsDlvrd OBJECT-TYPE The number of complete messages delivered over the given data channel. | 1.3.6.1.4.1.4253.2.1.27.3.1.11 | Counter | read-only | mandatory |
| oscClearCntrs OBJECT-TYPE If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other | 1.3.6.1.4.1.4253.2.1.27.3.1.12 | ResetType | read-write | mandatory |
| oscPmTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.1.27.4 | not-accessible | mandatory | |
| oscPmEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.27.4.1 | not-accessible | mandatory | |
| oscPmLocation OBJECT-TYPE The location of the OSC card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OSC cards. | 1.3.6.1.4.1.4253.2.1.27.4.1.1 | CardLocation | read-only | mandatory |
| oscPmShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OSC cards. | 1.3.6.1.4.1.4253.2.1.27.4.1.2 | CardShelf | read-only | mandatory |
| oscPmSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OSC cards. | 1.3.6.1.4.1.4253.2.1.27.4.1.3 | CardSlot | read-only | mandatory |
| oscPmErrors OBJECT-TYPE The number of packets errors since port last came online. | 1.3.6.1.4.1.4253.2.1.27.4.1.4 | Counter | read-only | mandatory |
| oscPmErredSecs OBJECT-TYPE The number of erred seconds since port last came online. | 1.3.6.1.4.1.4253.2.1.27.4.1.5 | Counter | read-only | mandatory |
| oscStartTime OBJECT-TYPE The date/time the port came last online. | 1.3.6.1.4.1.4253.2.1.27.4.1.6 | DateAndTime | read-only | mandatory |
| oscClearPmCntrs OBJECT-TYPE If the value is reset, all PM counters for this port are reset to zero. A get on this will always return other | 1.3.6.1.4.1.4253.2.1.27.4.1.7 | ResetType | read-write | mandatory |
| ocm4gPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.28 | |||
| ocm4gNumEvents OBJECT-TYPE Total number of all traps (events) generated by all OCM4G modules in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.28.1 | Counter | read-only | mandatory |
| ocm4gPerfTable OBJECT-TYPE This table represents the information for performance data collected for each OCM4G module. | 1.3.6.1.4.1.4253.2.1.28.2 | not-accessible | mandatory | |
| ocm4gPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.28.2.1 | not-accessible | mandatory | |
| ocm4gPerfLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.1.28.2.1.1 | INTEGER {local(1)} | read-only | mandatory |
| ocm4gPerfShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.1.28.2.1.2 | CardShelf | read-only | mandatory |
| ocm4gPerfSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.1.28.2.1.3 | CardSlot | read-only | mandatory |
| ocm4gPerfState OBJECT-TYPE The state of the OCM4G module. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.1.28.2.1.4 | CardState | read-only | mandatory |
| ocm4gPerfStatus OBJECT-TYPE The status of the OCM4G module. This status represents the status of the OCM4G module and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.28.2.1.5 | CardStatus | read-only | mandatory |
| ocm4gLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.1.28.2.1.6 | DateAndTime | read-only | mandatory |
| ocm4gAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.28.2.1.7 | Counter | read-only | mandatory |
| ocm4gErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.28.2.1.8 | Counter | read-only | mandatory |
| ocm4gCntrTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.1.28.3 | not-accessible | mandatory | |
| ocm4gCntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.28.3.1 | not-accessible | mandatory | |
| ocm4gCntrLocation OBJECT-TYPE The location of the OCM4G card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM4G cards. | 1.3.6.1.4.1.4253.2.1.28.3.1.1 | INTEGER {local(1)} | read-only | mandatory |
| ocm4gCntrShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM4G cards. | 1.3.6.1.4.1.4253.2.1.28.3.1.2 | CardShelf | read-only | mandatory |
| ocm4gCntrSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM4G cards. | 1.3.6.1.4.1.4253.2.1.28.3.1.3 | CardSlot | read-only | mandatory |
| ocm4gCntrType OBJECT-TYPE The type of the software counter data in this row. | 1.3.6.1.4.1.4253.2.1.28.3.1.4 | INTEGER {spi(1), ibm1(2), ibm2(3), hdlc(4)} | read-only | mandatory |
| ocm4gTotPktSent OBJECT-TYPE The number of data packets sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.28.3.1.5 | Counter | read-only | mandatory |
| ocm4gTotPktRcvd OBJECT-TYPE The number of data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.28.3.1.6 | Counter | read-only | mandatory |
| ocm4gTotBadTrans OBJECT-TYPE The number of bad data transmissions over the given data channel. | 1.3.6.1.4.1.4253.2.1.28.3.1.7 | Counter | read-only | mandatory |
| ocm4gBadPktRcvd OBJECT-TYPE The number of bad data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.1.28.3.1.8 | Counter | read-only | mandatory |
| ocm4gBytesSent OBJECT-TYPE Total number of bytes sent over the given data channel. | 1.3.6.1.4.1.4253.2.1.28.3.1.9 | Counter | read-only | mandatory |
| ocm4gBytesRcvd OBJECT-TYPE Total number of data bytes received over the given data channel. | 1.3.6.1.4.1.4253.2.1.28.3.1.10 | Counter | read-only | mandatory |
| ocm4gMsgsDlvrd OBJECT-TYPE The number of complete messages delivered over the given data channel. | 1.3.6.1.4.1.4253.2.1.28.3.1.11 | Counter | read-only | mandatory |
| ocm4gClearCntrs OBJECT-TYPE If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other | 1.3.6.1.4.1.4253.2.1.28.3.1.12 | ResetType | read-write | mandatory |
| ocm4gPmTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.1.28.4 | not-accessible | mandatory | |
| ocm4gPmEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.28.4.1 | not-accessible | mandatory | |
| ocm4gPmLocation OBJECT-TYPE The location of the OCM4G card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM4G cards. | 1.3.6.1.4.1.4253.2.1.28.4.1.1 | INTEGER {local(1)} | read-only | mandatory |
| ocm4gPmShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM4G cards. | 1.3.6.1.4.1.4253.2.1.28.4.1.2 | CardShelf | read-only | mandatory |
| ocm4gPmSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM4G cards. | 1.3.6.1.4.1.4253.2.1.28.4.1.3 | CardSlot | read-only | mandatory |
| ocm4gPmLink OBJECT-TYPE The link for which statistics are for. | 1.3.6.1.4.1.4253.2.1.28.4.1.4 | INTEGER {link1(1), link2(2)} | read-only | mandatory |
| ocm4gPmLinkRxPwr OBJECT-TYPE Link receive power. | 1.3.6.1.4.1.4253.2.1.28.4.1.5 | DisplayString | read-only | mandatory |
| ocm4gPmLinkTxPwr OBJECT-TYPE Link transmit power. | 1.3.6.1.4.1.4253.2.1.28.4.1.6 | DisplayString | read-only | mandatory |
| ocm4gPmCpeRxPwr OBJECT-TYPE CPE receive power. | 1.3.6.1.4.1.4253.2.1.28.4.1.7 | DisplayString | read-only | mandatory |
| ocm4gPmCpeTxPwr OBJECT-TYPE CPE transmit power. | 1.3.6.1.4.1.4253.2.1.28.4.1.8 | DisplayString | read-only | mandatory |
| ocm4gPmNumLinkRxIntervals OBJECT-TYPE The of intervals (seconds) over which the link Rx statistics have been accumulated. | 1.3.6.1.4.1.4253.2.1.28.4.1.9 | INTEGER | read-only | mandatory |
| ocm4gPmLinkRxErrors OBJECT-TYPE Link receive errors. | 1.3.6.1.4.1.4253.2.1.28.4.1.10 | DisplayString | read-only | mandatory |
| ocm4gPmLinkRxErredSeconds OBJECT-TYPE Link receive errored seconds. | 1.3.6.1.4.1.4253.2.1.28.4.1.11 | Counter | read-only | mandatory |
| ocm4gPmNumCpeRxIntervals OBJECT-TYPE The of intervals (seconds) over which the CPE Rx statistics have been accumulated. | 1.3.6.1.4.1.4253.2.1.28.4.1.12 | INTEGER | read-only | mandatory |
| ocm4gPmCpeRxErrors OBJECT-TYPE CPE receive errors. | 1.3.6.1.4.1.4253.2.1.28.4.1.13 | DisplayString | read-only | mandatory |
| ocm4gPmCpeRxErredSeconds OBJECT-TYPE CPE receive errored seconds. | 1.3.6.1.4.1.4253.2.1.28.4.1.14 | Counter | read-only | mandatory |
| ocm4gPmNumCpeTxIntervals OBJECT-TYPE The of intervals (seconds) over which the CPE Tx statistics have been accumulated. | 1.3.6.1.4.1.4253.2.1.28.4.1.15 | INTEGER | read-only | mandatory |
| ocm4gPmCpeTxErrors OBJECT-TYPE CPE transmit errors. | 1.3.6.1.4.1.4253.2.1.28.4.1.16 | DisplayString | read-only | mandatory |
| ocm4gPmCpeTxErredSeconds OBJECT-TYPE CPE transmit errored seconds. | 1.3.6.1.4.1.4253.2.1.28.4.1.17 | Counter | read-only | mandatory |
| ocm4gClearPmCntrs OBJECT-TYPE If the value is reset, all PM counters for this port are reset to zero. A get on this will always return other | 1.3.6.1.4.1.4253.2.1.28.4.1.18 | ResetType | read-write | mandatory |
| oetPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.29 | |||
| oetNumEvents OBJECT-TYPE Total number of all traps (events) generated by all OET modules in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.29.1 | Counter | read-only | mandatory |
| oetPerfTable OBJECT-TYPE This table represents the information for performance data collected for each OET module. | 1.3.6.1.4.1.4253.2.1.29.2 | not-accessible | mandatory | |
| oetPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.29.2.1 | not-accessible | mandatory | |
| oetPerfLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.1.29.2.1.1 | CardLocation | read-only | mandatory |
| oetPerfShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.1.29.2.1.2 | CardShelf | read-only | mandatory |
| oetPerfSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.1.29.2.1.3 | CardSlot | read-only | mandatory |
| oetPerfState OBJECT-TYPE The state of the OET module. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.1.29.2.1.4 | CardState | read-only | mandatory |
| oetPerfStatus OBJECT-TYPE The status of the OET module. This status represents the status of the OET module and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.29.2.1.5 | CardStatus | read-only | mandatory |
| oetLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.1.29.2.1.6 | DateAndTime | read-only | mandatory |
| oetAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.29.2.1.7 | Counter | read-only | mandatory |
| oetErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.29.2.1.8 | Counter | read-only | mandatory |
| oetPmLinkTable OBJECT-TYPE This table represents the information for each entry for the OET Link ports. | 1.3.6.1.4.1.4253.2.1.29.3 | not-accessible | mandatory | |
| oetPmLinkEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.29.3.1 | not-accessible | mandatory | |
| oetPmLinkLocation OBJECT-TYPE The location of the OET card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OET cards. | 1.3.6.1.4.1.4253.2.1.29.3.1.1 | CardLocation | read-only | mandatory |
| oetPmLinkShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OET cards. | 1.3.6.1.4.1.4253.2.1.29.3.1.2 | CardShelf | read-only | mandatory |
| oetPmLinkSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OET cards. | 1.3.6.1.4.1.4253.2.1.29.3.1.3 | CardSlot | read-only | mandatory |
| oetPmLink OBJECT-TYPE The link for which the statistics are for. | 1.3.6.1.4.1.4253.2.1.29.3.1.4 | INTEGER {linkA(11), linkB(12)} | read-only | mandatory |
| oetPmLinkNumIntervals OBJECT-TYPE The of intervals (seconds) over which the link statistics have been accumulated. | 1.3.6.1.4.1.4253.2.1.29.3.1.5 | INTEGER | read-only | mandatory |
| oetPmLinkRxPwr OBJECT-TYPE Link receive power. | 1.3.6.1.4.1.4253.2.1.29.3.1.6 | DisplayString | read-only | mandatory |
| oetPmLinkRxBytes OBJECT-TYPE Link Rx Bytes. | 1.3.6.1.4.1.4253.2.1.29.3.1.7 | DisplayString | read-only | mandatory |
| oetPmLinkRxFcsErrs OBJECT-TYPE Link Rx FCS Errors. | 1.3.6.1.4.1.4253.2.1.29.3.1.8 | DisplayString | read-only | mandatory |
| oetPmLinkTxPwr OBJECT-TYPE Link Tx power. | 1.3.6.1.4.1.4253.2.1.29.3.1.9 | DisplayString | read-only | mandatory |
| oetPmLinkTxTemp OBJECT-TYPE Pump temp in C | 1.3.6.1.4.1.4253.2.1.29.3.1.10 | DisplayString | read-only | mandatory |
| oetPmLinkTxBytes OBJECT-TYPE Link Tx Bytes. | 1.3.6.1.4.1.4253.2.1.29.3.1.11 | DisplayString | read-only | mandatory |
| oetPmLinkFecTx OBJECT-TYPE FEC Link Tx. | 1.3.6.1.4.1.4253.2.1.29.3.1.12 | DisplayString | read-only | mandatory |
| oetPmLinkFecCorrected1s OBJECT-TYPE FEC Corrected '1's | 1.3.6.1.4.1.4253.2.1.29.3.1.13 | INTEGER | read-only | mandatory |
| oetPmLinkFecCorrected0s OBJECT-TYPE FEC Corrected '0's | 1.3.6.1.4.1.4253.2.1.29.3.1.14 | INTEGER | read-only | mandatory |
| oetPmLinkFecCorrectedBit OBJECT-TYPE FEC Corrected Bits | 1.3.6.1.4.1.4253.2.1.29.3.1.15 | INTEGER | read-only | mandatory |
| oetPmLinkFecCorrectedByte OBJECT-TYPE FEC Corrected Bytes | 1.3.6.1.4.1.4253.2.1.29.3.1.16 | INTEGER | read-only | mandatory |
| oetPmLinkFecUncorrectedByte OBJECT-TYPE FEC Uncorrected Bytes | 1.3.6.1.4.1.4253.2.1.29.3.1.17 | INTEGER | read-only | mandatory |
| oetPmLinkFecBlock OBJECT-TYPE FEC Block Number | 1.3.6.1.4.1.4253.2.1.29.3.1.18 | INTEGER | read-only | mandatory |
| oetPmPortTable OBJECT-TYPE This table represents the information for each entry for the OET CPE ports. | 1.3.6.1.4.1.4253.2.1.29.4 | not-accessible | mandatory | |
| oetPmPortEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.29.4.1 | not-accessible | mandatory | |
| oetPmPortLocation OBJECT-TYPE The location of the OET card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OET cards. | 1.3.6.1.4.1.4253.2.1.29.4.1.1 | CardLocation | read-only | mandatory |
| oetPmPortShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OET cards. | 1.3.6.1.4.1.4253.2.1.29.4.1.2 | CardShelf | read-only | mandatory |
| oetPmPortSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OET cards. | 1.3.6.1.4.1.4253.2.1.29.4.1.3 | CardSlot | read-only | mandatory |
| oetPmPortIndex OBJECT-TYPE Port for which the statistics are for. | 1.3.6.1.4.1.4253.2.1.29.4.1.4 | INTEGER {cpe(10)} | read-only | mandatory |
| oetPmPortNumIntervals OBJECT-TYPE The of intervals (seconds) over which the port statistics have been accumulated. | 1.3.6.1.4.1.4253.2.1.29.4.1.5 | INTEGER | read-only | mandatory |
| oetPmPortRxPwr OBJECT-TYPE Port receive power. | 1.3.6.1.4.1.4253.2.1.29.4.1.6 | DisplayString | read-only | mandatory |
| oetPmPortRxBytes OBJECT-TYPE Port Rx Bytes. | 1.3.6.1.4.1.4253.2.1.29.4.1.7 | DisplayString | read-only | mandatory |
| oetPmPortRxFcsErrs OBJECT-TYPE Port Rx FCS Errors. | 1.3.6.1.4.1.4253.2.1.29.4.1.8 | DisplayString | read-only | mandatory |
| oetPmPortTxPwr OBJECT-TYPE Link Tx power. | 1.3.6.1.4.1.4253.2.1.29.4.1.9 | DisplayString | read-only | mandatory |
| oetPmPortTxTemp OBJECT-TYPE Pump temp in C | 1.3.6.1.4.1.4253.2.1.29.4.1.10 | DisplayString | read-only | mandatory |
| oetPmPortTxBytes OBJECT-TYPE Port Tx Bytes. | 1.3.6.1.4.1.4253.2.1.29.4.1.11 | DisplayString | read-only | mandatory |
| uobPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.30 | |||
| uobNumEvents OBJECT-TYPE Total number of all traps (events) generated by all UOB modules in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.30.1 | Counter | read-only | mandatory |
| uobPerfTable OBJECT-TYPE This table represents the information for performance data collected for each UOB module. | 1.3.6.1.4.1.4253.2.1.30.2 | not-accessible | mandatory | |
| uobPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.30.2.1 | not-accessible | mandatory | |
| uobPerfLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.1.30.2.1.1 | CardLocation | read-only | mandatory |
| uobPerfShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.1.30.2.1.2 | CardShelf | read-only | mandatory |
| uobPerfSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.1.30.2.1.3 | CardSlot | read-only | mandatory |
| uobPerfState OBJECT-TYPE The state of the UOB module. The states are: online = 2 and offline = 3 | 1.3.6.1.4.1.4253.2.1.30.2.1.4 | CardState | read-only | mandatory |
| uobPerfStatus OBJECT-TYPE This status represents the status of the UOB module and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.30.2.1.5 | CardStatus | read-only | mandatory |
| uobLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.1.30.2.1.6 | DateAndTime | read-only | mandatory |
| uobAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.30.2.1.7 | Counter | read-only | mandatory |
| uobErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.30.2.1.8 | Counter | read-only | mandatory |
| uobPmTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.1.30.3 | not-accessible | mandatory | |
| uobPmEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.30.3.1 | not-accessible | mandatory | |
| uobPmLocation OBJECT-TYPE The location of the UOB card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known UOB cards. | 1.3.6.1.4.1.4253.2.1.30.3.1.1 | CardLocation | read-only | mandatory |
| uobPmShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) UOB cards. | 1.3.6.1.4.1.4253.2.1.30.3.1.2 | CardShelf | read-only | mandatory |
| uobPmSlot OBJECT-TYPE The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) UOB cards. | 1.3.6.1.4.1.4253.2.1.30.3.1.3 | CardSlot | read-only | mandatory |
| uobPmSystemStatus OBJECT-TYPE System Status | 1.3.6.1.4.1.4253.2.1.30.3.1.4 | DisplayString | read-only | mandatory |
| uobPmPumpCurrent OBJECT-TYPE Pump Current in mA | 1.3.6.1.4.1.4253.2.1.30.3.1.5 | DisplayString | read-only | mandatory |
| uobPmPumpTemp OBJECT-TYPE Pump temp in C | 1.3.6.1.4.1.4253.2.1.30.3.1.6 | DisplayString | read-only | mandatory |
| uobPmInputPower OBJECT-TYPE Input pwr in dBm | 1.3.6.1.4.1.4253.2.1.30.3.1.7 | DisplayString | read-only | mandatory |
| uobPmOutPower OBJECT-TYPE Output pwr in dBm | 1.3.6.1.4.1.4253.2.1.30.3.1.8 | DisplayString | read-only | mandatory |
| uobPmTotalGain OBJECT-TYPE Total gain in dB | 1.3.6.1.4.1.4253.2.1.30.3.1.9 | DisplayString | read-only | mandatory |
| uobPmReflection OBJECT-TYPE Reflection in dB | 1.3.6.1.4.1.4253.2.1.30.3.1.10 | DisplayString | read-only | mandatory |
| fc8gPerf OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.1.31 | |||
| fc8gNumEvents OBJECT-TYPE Total number of all traps (events) generated by all FC8G modules in this time slot (15 minutes). | 1.3.6.1.4.1.4253.2.1.31.1 | Counter | read-only | mandatory |
| fc8gPerfTable OBJECT-TYPE This table represents the information for performance data collected for each FC8G module. | 1.3.6.1.4.1.4253.2.1.31.2 | not-accessible | mandatory | |
| fc8gPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.1.31.2.1 | not-accessible | mandatory | |
| fc8gPerfLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.1.31.2.1.1 | CardLocation | read-only | mandatory |
| fc8gPerfShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.1.31.2.1.2 | CardShelf | read-only | mandatory |
| fc8gPerfSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.1.31.2.1.3 | CardSlot | read-only | mandatory |
| fc8gPerfState OBJECT-TYPE The state of the FC8G module. The states are: online, offline, empty or loopback. | 1.3.6.1.4.1.4253.2.1.31.2.1.4 | CardState | read-only | mandatory |
| fc8gPerfStatus OBJECT-TYPE The status of the FC8G module. This status represents the status of the FC8G module and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.1.31.2.1.5 | CardStatus | read-only | mandatory |
| fc8gLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.1.31.2.1.6 | DateAndTime | read-only | mandatory |
| fc8gAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.1.31.2.1.7 | Counter | read-only | mandatory |
| fc8gErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.1.31.2.1.8 | Counter | read-only | mandatory |
| historical OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2 | |||
| systemHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.1 | |||
| sysHistTable OBJECT-TYPE This table represents the information for historical data collected for the overall system | 1.3.6.1.4.1.4253.2.2.1.1 | not-accessible | mandatory | |
| sysHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.1.1.1 | not-accessible | mandatory | |
| sysHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.1.1.1.1 | HistoryMode | read-only | mandatory |
| sysHLastBootTime OBJECT-TYPE The date and time of the last system boot. This time represents the boot time of a CP card. It is also anonymous with the power-up cycle of the chassis. | 1.3.6.1.4.1.4253.2.2.1.1.1.2 | DateAndTime | read-only | mandatory |
| sysHAvailTime OBJECT-TYPE The number of seconds since the system has been up and running. The criteria for the system available time is having at least one CP running with atmost non-service affecting minor alarm system status | 1.3.6.1.4.1.4253.2.2.1.1.1.3 | Counter | read-only | mandatory |
| sysHErrFreeSecs OBJECT-TYPE The number of seconds that the device has not experienced any alarms. This counter is across all cards in the chassis. The system must be in Normal status for this counter to be incremented. | 1.3.6.1.4.1.4253.2.2.1.1.1.4 | Counter | read-only | mandatory |
| downloadHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.2 | |||
| dlHistTable OBJECT-TYPE This table represents the information for historical data collected for the download process | 1.3.6.1.4.1.4253.2.2.2.1 | not-accessible | mandatory | |
| dlHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.2.1.1 | not-accessible | mandatory | |
| dlHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.2.1.1.1 | HistoryMode | read-only | mandatory |
| dlHOkDownloads OBJECT-TYPE The number of successful downloads | 1.3.6.1.4.1.4253.2.2.2.1.1.2 | Counter | read-only | mandatory |
| dlHBadDownloads OBJECT-TYPE The number of failed downloads | 1.3.6.1.4.1.4253.2.2.2.1.1.3 | Counter | read-only | mandatory |
| dlHLongestTime OBJECT-TYPE Longest time for any download, in seconds | 1.3.6.1.4.1.4253.2.2.2.1.1.4 | Gauge | read-only | mandatory |
| dlHLongestSize OBJECT-TYPE Longest download size for any download, in bytes | 1.3.6.1.4.1.4253.2.2.2.1.1.5 | Gauge | read-only | mandatory |
| cpHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.3 | |||
| cpHistTable OBJECT-TYPE This table represents the information for historical data collected for the communication card | 1.3.6.1.4.1.4253.2.2.3.1 | not-accessible | mandatory | |
| cpHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.3.1.1 | not-accessible | mandatory | |
| cpHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.3.1.1.1 | HistoryMode | read-only | mandatory |
| cpHNumEvents OBJECT-TYPE Total number of events received by the active CP | 1.3.6.1.4.1.4253.2.2.3.1.1.2 | Counter | read-only | mandatory |
| cpHTrapsSent OBJECT-TYPE Total number of traps sent by the active CP | 1.3.6.1.4.1.4253.2.2.3.1.1.3 | Counter | read-only | mandatory |
| cpHSNMPCmdsRcvd OBJECT-TYPE Total number of SNMP commands received by the active CP. | 1.3.6.1.4.1.4253.2.2.3.1.1.4 | Counter | read-only | mandatory |
| cpHCntrTable OBJECT-TYPE This table represents the information for each entry for the software counters. It is only applicable to the active MPM card. | 1.3.6.1.4.1.4253.2.2.3.2 | not-accessible | mandatory | |
| cpHCntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.3.2.1 | not-accessible | mandatory | |
| cpHCntrMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.3.2.1.1 | HistoryMode | read-only | mandatory |
| cpHCntrShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10. The system automatically determines the right value for this entry based on the value of the current active CP card. | 1.3.6.1.4.1.4253.2.2.3.2.1.2 | CardShelf | read-only | mandatory |
| cpHCntrSlot OBJECT-TYPE The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the value of the current active CP card. | 1.3.6.1.4.1.4253.2.2.3.2.1.3 | CardSlot | read-only | mandatory |
| cpHCntrType OBJECT-TYPE The type of the software counter data in this row. The data is collected for the SPI data channels. | 1.3.6.1.4.1.4253.2.2.3.2.1.4 | INTEGER {spi(1)} | read-only | mandatory |
| cpHTotPktSent OBJECT-TYPE The number of data packets sent over the given data channel. | 1.3.6.1.4.1.4253.2.2.3.2.1.5 | Counter | read-only | mandatory |
| cpHTotPktRcvd OBJECT-TYPE The number of data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.2.3.2.1.6 | Counter | read-only | mandatory |
| cpHBadPktRcvd OBJECT-TYPE The number of bad data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.2.3.2.1.7 | Counter | read-only | mandatory |
| cpHTotBadTrans OBJECT-TYPE The number of bad data transmissions over the given data channel. | 1.3.6.1.4.1.4253.2.2.3.2.1.8 | Counter | read-only | mandatory |
| cpHBytesSent OBJECT-TYPE Total number of bytes sent over the given data channel. | 1.3.6.1.4.1.4253.2.2.3.2.1.9 | Counter | read-only | mandatory |
| cpHBytesRcvd OBJECT-TYPE Total number of data bytes received over the given data channel. | 1.3.6.1.4.1.4253.2.2.3.2.1.10 | Counter | read-only | mandatory |
| cpHMsgsDlvrd OBJECT-TYPE The number of complete messages delivered over the given data channel. | 1.3.6.1.4.1.4253.2.2.3.2.1.11 | Counter | read-only | mandatory |
| cpHBufAllocFail OBJECT-TYPE Number of buffer allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.2.3.2.1.12 | Counter | read-only | mandatory |
| cpHEcbAllocFail OBJECT-TYPE Number of Event Control Block allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.2.3.2.1.13 | Counter | read-only | mandatory |
| cpHHistTable OBJECT-TYPE This table represents the information for performance data collected for each communication processor | 1.3.6.1.4.1.4253.2.2.3.3 | not-accessible | mandatory | |
| cpHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.3.3.1 | not-accessible | mandatory | |
| cpHHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.3.3.1.1 | HistoryMode | read-only | mandatory |
| cpHHistShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.2.3.3.1.2 | CardShelf | read-only | mandatory |
| cpHHistSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.2.3.3.1.3 | CardSlot | read-only | mandatory |
| cpHLastBootTime OBJECT-TYPE The date and time of the last boot for this CP. | 1.3.6.1.4.1.4253.2.2.3.3.1.4 | DateAndTime | read-only | mandatory |
| cpHAvailTime OBJECT-TYPE The number of seconds that this CP has been up and running. | 1.3.6.1.4.1.4253.2.2.3.3.1.5 | Counter | read-only | mandatory |
| cpHErrFreeSecs OBJECT-TYPE The number of seconds that this CP has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.3.3.1.6 | Counter | read-only | mandatory |
| ccHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.4 | |||
| ccHistTable OBJECT-TYPE This table represents the information for historical data collected for the channel card | 1.3.6.1.4.1.4253.2.2.4.1 | not-accessible | mandatory | |
| ccHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.4.1.1 | not-accessible | mandatory | |
| ccHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.4.1.1.1 | HistoryMode | read-only | mandatory |
| ccHNumEvents OBJECT-TYPE Total number of events received for all CC's | 1.3.6.1.4.1.4253.2.2.4.1.1.2 | Counter | read-only | mandatory |
| ccHCntrTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.2.4.2 | not-accessible | mandatory | |
| ccHCntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.4.2.1 | not-accessible | mandatory | |
| ccHCntrMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.4.2.1.1 | HistoryMode | read-only | mandatory |
| ccHCntrLocation OBJECT-TYPE The location of the CC card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known CC cards. | 1.3.6.1.4.1.4253.2.2.4.2.1.2 | CardLocation | read-only | mandatory |
| ccHCntrShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10. The system automatically determines the right value for this entry based on the known (available) CC cards. | 1.3.6.1.4.1.4253.2.2.4.2.1.3 | CardShelf | read-only | mandatory |
| ccHCntrSlot OBJECT-TYPE The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) CC cards. | 1.3.6.1.4.1.4253.2.2.4.2.1.4 | CardSlot | read-only | mandatory |
| ccHCntrType OBJECT-TYPE The type of the software counter data in this row. The data is collected for the SPI data channels. | 1.3.6.1.4.1.4253.2.2.4.2.1.5 | INTEGER {spi(1), iwm(2)} | read-only | mandatory |
| ccHTotPktSent OBJECT-TYPE The number of data packets sent over the given data channel. | 1.3.6.1.4.1.4253.2.2.4.2.1.6 | Counter | read-only | mandatory |
| ccHTotPktRcvd OBJECT-TYPE The number of data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.2.4.2.1.7 | Counter | read-only | mandatory |
| ccHBadPktRcvd OBJECT-TYPE The number of bad data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.2.4.2.1.8 | Counter | read-only | mandatory |
| ccHTotBadTrans OBJECT-TYPE The number of bad data transmissions over the given data channel. | 1.3.6.1.4.1.4253.2.2.4.2.1.9 | Counter | read-only | mandatory |
| ccHBytesSent OBJECT-TYPE Total number of bytes sent over the given data channel. | 1.3.6.1.4.1.4253.2.2.4.2.1.10 | Counter | read-only | mandatory |
| ccHBytesRcvd OBJECT-TYPE Total number of data bytes received over the given data channel. | 1.3.6.1.4.1.4253.2.2.4.2.1.11 | Counter | read-only | mandatory |
| ccHMsgsDlvrd OBJECT-TYPE The number of complete messages delivered over the given data channel. | 1.3.6.1.4.1.4253.2.2.4.2.1.12 | Counter | read-only | mandatory |
| ccHBufAllocFail OBJECT-TYPE Number of buffer allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.2.4.2.1.13 | Counter | read-only | mandatory |
| ccHEcbAllocFail OBJECT-TYPE Number of Event Control Block allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.2.4.2.1.14 | Counter | read-only | mandatory |
| ccHHistTable OBJECT-TYPE This table represents the information for performance data collected for each channel card | 1.3.6.1.4.1.4253.2.2.4.3 | not-accessible | mandatory | |
| ccHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.4.3.1 | not-accessible | mandatory | |
| ccHHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.4.3.1.1 | HistoryMode | read-only | mandatory |
| ccHHistLocation OBJECT-TYPE The location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) CC cards. | 1.3.6.1.4.1.4253.2.2.4.3.1.2 | CardLocation | read-only | mandatory |
| ccHHistShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.2.4.3.1.3 | CardShelf | read-only | mandatory |
| ccHHistSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.2.4.3.1.4 | CardSlot | read-only | mandatory |
| ccHLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.2.4.3.1.5 | DateAndTime | read-only | mandatory |
| ccHAvailTime OBJECT-TYPE The number of seconds that this CC has been up and running. | 1.3.6.1.4.1.4253.2.2.4.3.1.6 | Counter | read-only | mandatory |
| ccHErrFreeSecs OBJECT-TYPE The number of seconds that this CC has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.4.3.1.7 | Counter | read-only | mandatory |
| muxHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.5 | |||
| muxHistTable OBJECT-TYPE This table represents the information for historical data collected for the mux/demux card | 1.3.6.1.4.1.4253.2.2.5.1 | not-accessible | mandatory | |
| muxHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.5.1.1 | not-accessible | mandatory | |
| muxHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.5.1.1.1 | HistoryMode | read-only | mandatory |
| muxHNumEvents OBJECT-TYPE Total number of all traps (events) generated by all MUX's. | 1.3.6.1.4.1.4253.2.2.5.1.1.2 | Counter | read-only | mandatory |
| muxHHistTable OBJECT-TYPE This table represents the information for performance data collected for each mux/demux card | 1.3.6.1.4.1.4253.2.2.5.2 | not-accessible | mandatory | |
| muxHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.5.2.1 | not-accessible | mandatory | |
| muxHHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.5.2.1.1 | HistoryMode | read-only | mandatory |
| muxHHistLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.2.5.2.1.2 | CardLocation | read-only | mandatory |
| muxHHistShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.2.5.2.1.3 | CardShelf | read-only | mandatory |
| muxHHistSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.2.5.2.1.4 | CardSlot | read-only | mandatory |
| muxHHistType OBJECT-TYPE The type of the mux. The choices are: mux or demux. | 1.3.6.1.4.1.4253.2.2.5.2.1.5 | INTEGER {mux(4), demux(5), w4cd(10), w2cmd(13), w4cm(21)} | read-only | mandatory |
| muxHLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.2.5.2.1.6 | DateAndTime | read-only | mandatory |
| muxHAvailTime OBJECT-TYPE The number of seconds that this Mux has been up and running. | 1.3.6.1.4.1.4253.2.2.5.2.1.7 | Counter | read-only | mandatory |
| muxHErrFreeSecs OBJECT-TYPE The number of seconds that this mux has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.5.2.1.8 | Counter | read-only | mandatory |
| psHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.6 | |||
| psHistTable OBJECT-TYPE This table represents the information for historical data collected for the power supply card | 1.3.6.1.4.1.4253.2.2.6.1 | not-accessible | mandatory | |
| psHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.6.1.1 | not-accessible | mandatory | |
| psHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.6.1.1.1 | HistoryMode | not-accessible | mandatory |
| psHNumEvents OBJECT-TYPE Total number of all traps (events) generated by all Power Supplies. | 1.3.6.1.4.1.4253.2.2.6.1.1.2 | Counter | not-accessible | mandatory |
| fadmHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.7 | |||
| fadmHistTable OBJECT-TYPE This table represents the information for historical data collected for the fadm card | 1.3.6.1.4.1.4253.2.2.7.1 | not-accessible | mandatory | |
| fadmHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.7.1.1 | not-accessible | mandatory | |
| fadmHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.7.1.1.1 | HistoryMode | read-only | mandatory |
| fadmHNumEvents OBJECT-TYPE Total number of all traps (events) generated by all FADM's. | 1.3.6.1.4.1.4253.2.2.7.1.1.2 | Counter | read-only | mandatory |
| fadmHHistTable OBJECT-TYPE This table represents the information for performance data collected for each fadm card | 1.3.6.1.4.1.4253.2.2.7.2 | not-accessible | mandatory | |
| fadmHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.7.2.1 | not-accessible | mandatory | |
| fadmHHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.7.2.1.1 | HistoryMode | read-only | mandatory |
| fadmHHistLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.2.7.2.1.2 | CardLocation | read-only | mandatory |
| fadmHHistShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.2.7.2.1.3 | CardShelf | read-only | mandatory |
| fadmHHistSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.2.7.2.1.4 | CardSlot | read-only | mandatory |
| fadmHLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.2.7.2.1.6 | DateAndTime | read-only | mandatory |
| fadmHAvailTime OBJECT-TYPE The number of seconds that this Mux has been up and running. | 1.3.6.1.4.1.4253.2.2.7.2.1.7 | Counter | read-only | mandatory |
| fadmHErrFreeSecs OBJECT-TYPE The number of seconds that this mux has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.7.2.1.8 | Counter | read-only | mandatory |
| oppmHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.8 | |||
| oppmHistTable OBJECT-TYPE This table represents the information for historical data collected for the oppm card | 1.3.6.1.4.1.4253.2.2.8.1 | not-accessible | mandatory | |
| oppmHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.8.1.1 | not-accessible | mandatory | |
| oppmHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.8.1.1.1 | HistoryMode | not-accessible | mandatory |
| oppmHNumEvents OBJECT-TYPE Total number of all traps (events) generated by all OPPM's. | 1.3.6.1.4.1.4253.2.2.8.1.1.2 | Counter | not-accessible | mandatory |
| oppmHHistTable OBJECT-TYPE This table represents the information for performance data collected for each fadm card | 1.3.6.1.4.1.4253.2.2.8.2 | not-accessible | mandatory | |
| oppmHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.8.2.1 | not-accessible | mandatory | |
| oppmHHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.8.2.1.1 | HistoryMode | not-accessible | mandatory |
| oppmHHistLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.2.8.2.1.2 | CardLocation | not-accessible | mandatory |
| oppmHHistShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.2.8.2.1.3 | CardShelf | not-accessible | mandatory |
| oppmHHistSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.2.8.2.1.4 | CardSlot | not-accessible | mandatory |
| oppmHLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.2.8.2.1.6 | DateAndTime | not-accessible | mandatory |
| oppmHAvailTime OBJECT-TYPE The number of seconds that this Mux has been up and running. | 1.3.6.1.4.1.4253.2.2.8.2.1.7 | Counter | not-accessible | mandatory |
| oppmHErrFreeSecs OBJECT-TYPE The number of seconds that this mux has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.8.2.1.8 | Counter | not-accessible | mandatory |
| mcmHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.9 | |||
| mcmHistTable OBJECT-TYPE This table represents the information for historical data collected for the channel card | 1.3.6.1.4.1.4253.2.2.9.1 | not-accessible | mandatory | |
| mcmHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.9.1.1 | not-accessible | mandatory | |
| mcmHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.9.1.1.1 | HistoryMode | read-only | mandatory |
| mcmHNumEvents OBJECT-TYPE Total number of events received for all mcmt1's/mcme1's | 1.3.6.1.4.1.4253.2.2.9.1.1.2 | Counter | read-only | mandatory |
| mcmHCntrTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.2.9.2 | not-accessible | mandatory | |
| mcmHCntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.9.2.1 | not-accessible | mandatory | |
| mcmHCntrMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.9.2.1.1 | HistoryMode | read-only | mandatory |
| mcmHCntrLocation OBJECT-TYPE The location of the mcm/mcme1 card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmt1/mcme1 cards. | 1.3.6.1.4.1.4253.2.2.9.2.1.2 | CardLocation | read-only | mandatory |
| mcmHCntrShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards. | 1.3.6.1.4.1.4253.2.2.9.2.1.3 | CardShelf | read-only | mandatory |
| mcmHCntrSlot OBJECT-TYPE The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards. | 1.3.6.1.4.1.4253.2.2.9.2.1.4 | CardSlot | read-only | mandatory |
| mcmHCntrType OBJECT-TYPE The type of the software counter data in this row. The data is collected for the SPI data channels. | 1.3.6.1.4.1.4253.2.2.9.2.1.5 | INTEGER {spi(1), iwm(2)} | read-only | mandatory |
| mcmHTotPktSent OBJECT-TYPE The number of data packets sent over the given data channel. | 1.3.6.1.4.1.4253.2.2.9.2.1.6 | Counter | read-only | mandatory |
| mcmHTotPktRcvd OBJECT-TYPE The number of data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.2.9.2.1.7 | Counter | read-only | mandatory |
| mcmHBadPktRcvd OBJECT-TYPE The number of bad data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.2.9.2.1.8 | Counter | read-only | mandatory |
| mcmHTotBadTrans OBJECT-TYPE The number of bad data transmissions over the given data channel. | 1.3.6.1.4.1.4253.2.2.9.2.1.9 | Counter | read-only | mandatory |
| mcmHBytesSent OBJECT-TYPE Total number of bytes sent over the given data channel. | 1.3.6.1.4.1.4253.2.2.9.2.1.10 | Counter | read-only | mandatory |
| mcmHBytesRcvd OBJECT-TYPE Total number of data bytes received over the given data channel. | 1.3.6.1.4.1.4253.2.2.9.2.1.11 | Counter | read-only | mandatory |
| mcmHMsgsDlvrd OBJECT-TYPE The number of complete messages delivered over the given data channel. | 1.3.6.1.4.1.4253.2.2.9.2.1.12 | Counter | read-only | mandatory |
| mcmHBufAllocFail OBJECT-TYPE Number of buffer allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.2.9.2.1.13 | Counter | read-only | mandatory |
| mcmHEcbAllocFail OBJECT-TYPE Number of Event Control Block allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.2.9.2.1.14 | Counter | read-only | mandatory |
| mcmPortHIntervalTable OBJECT-TYPE This table represents the information for each entry for the mcmt1/mcme1 port counters. | 1.3.6.1.4.1.4253.2.2.9.3 | not-accessible | mandatory | |
| mcmPortHIntervalEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.9.3.1 | not-accessible | mandatory | |
| mcmPortHIntervalLocation OBJECT-TYPE The location of the mcm/mcme1 card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcm/mcme1 cards. | 1.3.6.1.4.1.4253.2.2.9.3.1.1 | CardLocation | read-only | mandatory |
| mcmPortHIntervalShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards. | 1.3.6.1.4.1.4253.2.2.9.3.1.2 | CardShelf | read-only | mandatory |
| mcmPortHIntervalSlot OBJECT-TYPE The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards. | 1.3.6.1.4.1.4253.2.2.9.3.1.3 | CardSlot | read-only | mandatory |
| mcmPortHIntervalPort OBJECT-TYPE The port within the shelf the card is in. Valid values are: 1 to 4. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards. | 1.3.6.1.4.1.4253.2.2.9.3.1.4 | INTEGER | read-only | mandatory |
| mcmPortHIntervalNumber OBJECT-TYPE The Interval number of the ds1 port. Valid values are: 1 to 96. The system automatically determines the right value for this entry based on the known (available) interval number. | 1.3.6.1.4.1.4253.2.2.9.3.1.5 | INTEGER | read-only | mandatory |
| mcmPortHIntervalASs OBJECT-TYPE MCMT1/MCME1 port's ASs counter for specific interval. | 1.3.6.1.4.1.4253.2.2.9.3.1.6 | Counter | read-only | mandatory |
| mcmPortHIntervalFrameASs OBJECT-TYPE MCMT1/MCME1 port's FrameASs counter for specific interval. | 1.3.6.1.4.1.4253.2.2.9.3.1.7 | Counter | not-accessible | mandatory |
| mcmPortHIntervalFEs OBJECT-TYPE MCMT1/MCME1 port's FEs counter for specific interval. | 1.3.6.1.4.1.4253.2.2.9.3.1.8 | Counter | read-only | mandatory |
| mcmPortHIntervalCRCErrs OBJECT-TYPE MCMT1/MCME1 port's CRC errs counter for specific interval. | 1.3.6.1.4.1.4253.2.2.9.3.1.9 | Counter | read-only | mandatory |
| mcmPortHIntervalSESs OBJECT-TYPE MCMT1/MCME1 port's SESs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.2.9.3.1.10 | Counter | read-only | mandatory |
| mcmPortHIntervalSEFSs OBJECT-TYPE MCMT1/MCME1 port's SEFSs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.2.9.3.1.11 | Counter | read-only | mandatory |
| mcmPortHIntervalUASs OBJECT-TYPE MCMT1/MCME1 port's UASs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.2.9.3.1.12 | Counter | read-only | mandatory |
| mcmPortHIntervalLESs OBJECT-TYPE MCMT1/MCME1 port's LESs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.2.9.3.1.13 | Counter | read-only | mandatory |
| mcmPortHIntervalBESs OBJECT-TYPE MCMT1/MCME1 port's BESs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.2.9.3.1.14 | Counter | read-only | mandatory |
| mcmPortHIntervalDMs OBJECT-TYPE MCMT1/MCME1 port's DMSs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.2.9.3.1.15 | Counter | read-only | mandatory |
| mcmPortHIntervalLCVs OBJECT-TYPE MCMT1/MCME1 port's LCVs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.2.9.3.1.16 | Counter | read-only | mandatory |
| mcmPortHTotalTable OBJECT-TYPE This table represents the information for each entry for the mcmt1/mcme1 port counters. | 1.3.6.1.4.1.4253.2.2.9.4 | not-accessible | mandatory | |
| mcmPortHTotalEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.9.4.1 | not-accessible | mandatory | |
| mcmPortHTotalLocation OBJECT-TYPE The location of the mcm card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcm/mcme1 cards. | 1.3.6.1.4.1.4253.2.2.9.4.1.1 | CardLocation | read-only | mandatory |
| mcmPortHTotalShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards. | 1.3.6.1.4.1.4253.2.2.9.4.1.2 | CardShelf | read-only | mandatory |
| mcmPortHTotalSlot OBJECT-TYPE The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards. | 1.3.6.1.4.1.4253.2.2.9.4.1.3 | CardSlot | read-only | mandatory |
| mcmPortHTotalPort OBJECT-TYPE The port within the shelf the card is in. Valid values are: 1 to 4. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards. | 1.3.6.1.4.1.4253.2.2.9.4.1.4 | INTEGER | read-only | mandatory |
| mcmPortHTotalASs OBJECT-TYPE MCMT1/MCME1 port's ASs counter for the last 24 hrs. | 1.3.6.1.4.1.4253.2.2.9.4.1.5 | Counter | read-only | mandatory |
| mcmPortHTotalFrameASs OBJECT-TYPE MCMT1/MCME1 port's FrameASs counter for the last 24 hrs. | 1.3.6.1.4.1.4253.2.2.9.4.1.6 | Counter | not-accessible | mandatory |
| mcmPortHTotalFEs OBJECT-TYPE MCMT1/MCME1 port's FEs counter for the last 24 hrs. | 1.3.6.1.4.1.4253.2.2.9.4.1.7 | Counter | read-only | mandatory |
| mcmPortHTotalCRCErrs OBJECT-TYPE MCMT1/MCME1 port's CRC errs counter for the last 24 hrs. | 1.3.6.1.4.1.4253.2.2.9.4.1.8 | Counter | read-only | mandatory |
| mcmPortHTotalSESs OBJECT-TYPE MCMT1/MCME1 port's SESs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.2.9.4.1.9 | Counter | read-only | mandatory |
| mcmPortHTotalSEFSs OBJECT-TYPE MCMT1/MCME1 port's SEFSs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.2.9.4.1.10 | Counter | read-only | mandatory |
| mcmPortHTotalUASs OBJECT-TYPE MCMT1/MCME1 port's UASs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.2.9.4.1.11 | Counter | read-only | mandatory |
| mcmPortHTotalLESs OBJECT-TYPE MCMT1/MCME1 port's LESs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.2.9.4.1.12 | Counter | read-only | mandatory |
| mcmPortHTotalBESs OBJECT-TYPE MCMT1/MCME1 port's BESs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.2.9.4.1.13 | Counter | read-only | mandatory |
| mcmPortHTotalDMs OBJECT-TYPE MCMT1/MCME1 port's DMSs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.2.9.4.1.14 | Counter | read-only | mandatory |
| mcmPortHTotalLCVs OBJECT-TYPE MCMT1/MCME1 port's LCVs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.2.9.4.1.15 | Counter | read-only | mandatory |
| fnHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.10 | |||
| fnHistTable OBJECT-TYPE This table represents the information for historical data collected for the fan modules | 1.3.6.1.4.1.4253.2.2.10.1 | not-accessible | mandatory | |
| fnHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.10.1.1 | not-accessible | mandatory | |
| fnHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.10.1.1.1 | HistoryMode | not-accessible | mandatory |
| fnHNumEvents OBJECT-TYPE Total number of all traps (events) generated by all fan modules. | 1.3.6.1.4.1.4253.2.2.10.1.1.2 | Counter | not-accessible | mandatory |
| csimHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.11 | |||
| csimHistTable OBJECT-TYPE This table represents the information for historical data collected for the ColorSIM | 1.3.6.1.4.1.4253.2.2.11.1 | not-accessible | mandatory | |
| csimHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.11.1.1 | not-accessible | mandatory | |
| csimHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. The reason this has been made obsolete is that all colorsim related events would eventually be part of ocm events | 1.3.6.1.4.1.4253.2.2.11.1.1.1 | HistoryMode | not-accessible | mandatory |
| csimHNumEvents OBJECT-TYPE This variable keeps track of the number of events related to ColorSIM. The reason this has been made obsolete is that all colorsim related events would eventually be part of ocm events | 1.3.6.1.4.1.4253.2.2.11.1.1.2 | Counter | not-accessible | mandatory |
| csimHistIntervalTable OBJECT-TYPE This table represents the information for each colorsim card. | 1.3.6.1.4.1.4253.2.2.11.2 | not-accessible | mandatory | |
| csimHistIntervalEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.11.2.1 | not-accessible | mandatory | |
| csimIntervalLocation OBJECT-TYPE Location of the ColorSIM module | 1.3.6.1.4.1.4253.2.2.11.2.1.1 | CardLocation | read-only | mandatory |
| csimIntervalShelf OBJECT-TYPE The shelf of the ColorSIM module | 1.3.6.1.4.1.4253.2.2.11.2.1.2 | CardShelf | read-only | mandatory |
| csimIntervalSlot OBJECT-TYPE The Slot of the ColorSIM module | 1.3.6.1.4.1.4253.2.2.11.2.1.3 | CardSlot | read-only | mandatory |
| csimIntervalNumber OBJECT-TYPE This variable indicates the interval for which the set of statistics data is available. | 1.3.6.1.4.1.4253.2.2.11.2.1.4 | INTEGER (1..96) | read-only | mandatory |
| csimIntervalEFIs OBJECT-TYPE The counter associated with the number of Error Free Interval Counts in this interval. | 1.3.6.1.4.1.4253.2.2.11.2.1.5 | INTEGER | read-only | mandatory |
| csimIntervalEIs OBJECT-TYPE The counter associated with the number of Errored Interval Counts in this interval. | 1.3.6.1.4.1.4253.2.2.11.2.1.6 | INTEGER | read-only | mandatory |
| csimIntervalSEIs OBJECT-TYPE The counter associated with the number of Severely Errored Interval Counts in this interval. | 1.3.6.1.4.1.4253.2.2.11.2.1.7 | INTEGER | read-only | mandatory |
| csimIntervalBERs OBJECT-TYPE The counter associated with the number of Bit Error Rate Counts in this interval. The unit is in the form of x.ye-z. | 1.3.6.1.4.1.4253.2.2.11.2.1.8 | DisplayString | read-only | mandatory |
| csimIntervalUAIs OBJECT-TYPE The counter associated with the number of Unavailable Interval Counts in this interval. | 1.3.6.1.4.1.4253.2.2.11.2.1.9 | INTEGER | read-only | mandatory |
| csimIntervalValidData OBJECT-TYPE This variable indicates if the data for this interval is valid. Not supported | 1.3.6.1.4.1.4253.2.2.11.2.1.10 | Boolean | not-accessible | mandatory |
| csimIntervalDateTime OBJECT-TYPE Time in seconds elasped since 01/01/1970 00:00:00 GMT for this interval. Assuming local time is same as GMT | 1.3.6.1.4.1.4253.2.2.11.2.1.11 | INTEGER | read-only | mandatory |
| rpsmHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.12 | |||
| rpsmHistTable OBJECT-TYPE This table represents the information for historical data collected for the rpsm card | 1.3.6.1.4.1.4253.2.2.12.1 | not-accessible | mandatory | |
| rpsmHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.12.1.1 | not-accessible | mandatory | |
| rpsmHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.12.1.1.1 | HistoryMode | not-accessible | mandatory |
| rpsmHNumEvents OBJECT-TYPE Total number of all traps (events) generated by all RPSM's. | 1.3.6.1.4.1.4253.2.2.12.1.1.2 | Counter | not-accessible | mandatory |
| rpsmHHistTable OBJECT-TYPE This table represents the information for performance data collected for each rpsm card | 1.3.6.1.4.1.4253.2.2.12.2 | not-accessible | mandatory | |
| rpsmHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.12.2.1 | not-accessible | mandatory | |
| rpsmHHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.12.2.1.1 | HistoryMode | not-accessible | mandatory |
| rpsmHHistLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.2.12.2.1.2 | CardLocation | not-accessible | mandatory |
| rpsmHHistShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.2.12.2.1.3 | CardShelf | not-accessible | mandatory |
| rpsmHHistSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.2.12.2.1.4 | CardSlot | not-accessible | mandatory |
| rpsmHLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.2.12.2.1.6 | DateAndTime | not-accessible | mandatory |
| rpsmHAvailTime OBJECT-TYPE The number of seconds that this rpsm has been up and running. | 1.3.6.1.4.1.4253.2.2.12.2.1.7 | Counter | not-accessible | mandatory |
| rpsmHErrFreeSecs OBJECT-TYPE The number of seconds that this rpsm has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.12.2.1.8 | Counter | not-accessible | mandatory |
| rsdmHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.13 | |||
| rsdmHistTable OBJECT-TYPE This table represents the information for historical data collected for the rsdm card | 1.3.6.1.4.1.4253.2.2.13.1 | not-accessible | mandatory | |
| rsdmHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.13.1.1 | not-accessible | mandatory | |
| rsdmHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.13.1.1.1 | HistoryMode | not-accessible | mandatory |
| rsdmHNumEvents OBJECT-TYPE Total number of all traps (events) generated by all RSDM's. | 1.3.6.1.4.1.4253.2.2.13.1.1.2 | Counter | not-accessible | mandatory |
| rsdmHHistTable OBJECT-TYPE This table represents the information for performance data collected for each rsdm card. | 1.3.6.1.4.1.4253.2.2.13.2 | not-accessible | mandatory | |
| rsdmHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.13.2.1 | not-accessible | mandatory | |
| rsdmHHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.13.2.1.1 | HistoryMode | not-accessible | mandatory |
| rsdmHHistLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.2.13.2.1.2 | CardLocation | not-accessible | mandatory |
| rsdmHHistShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.2.13.2.1.3 | CardShelf | not-accessible | mandatory |
| rsdmHHistSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.2.13.2.1.4 | CardSlot | not-accessible | mandatory |
| rsdmHLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.2.13.2.1.6 | DateAndTime | not-accessible | mandatory |
| rsdmHAvailTime OBJECT-TYPE The number of seconds that this rsdm has been up and running. | 1.3.6.1.4.1.4253.2.2.13.2.1.7 | Counter | not-accessible | mandatory |
| rsdmHErrFreeSecs OBJECT-TYPE The number of seconds that this rsdm has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.13.2.1.8 | Counter | not-accessible | mandatory |
| rtdmHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.14 | |||
| rtdmHistTable OBJECT-TYPE This table represents the information for historical data collected for the rtdm card | 1.3.6.1.4.1.4253.2.2.14.1 | not-accessible | mandatory | |
| rtdmHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.14.1.1 | not-accessible | mandatory | |
| rtdmHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.14.1.1.1 | HistoryMode | not-accessible | mandatory |
| rtdmHNumEvents OBJECT-TYPE Total number of all traps (events) generated by all rtdm's. | 1.3.6.1.4.1.4253.2.2.14.1.1.2 | Counter | not-accessible | mandatory |
| rtdmHHistTable OBJECT-TYPE This table represents the information for performance data collected for each rtdm card. | 1.3.6.1.4.1.4253.2.2.14.2 | not-accessible | mandatory | |
| rtdmHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.14.2.1 | not-accessible | mandatory | |
| rtdmHHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.14.2.1.1 | HistoryMode | not-accessible | mandatory |
| rtdmHHistLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.2.14.2.1.2 | CardLocation | not-accessible | mandatory |
| rtdmHHistShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.2.14.2.1.3 | CardShelf | not-accessible | mandatory |
| rtdmHHistSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.2.14.2.1.4 | CardSlot | not-accessible | mandatory |
| rtdmHLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.2.14.2.1.5 | DateAndTime | not-accessible | mandatory |
| rtdmHAvailTime OBJECT-TYPE The number of seconds that this rtdm has been up and running. | 1.3.6.1.4.1.4253.2.2.14.2.1.6 | Counter | not-accessible | mandatory |
| rtdmHErrFreeSecs OBJECT-TYPE The number of seconds that this rtdm has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.14.2.1.7 | Counter | not-accessible | mandatory |
| osamHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.15 | |||
| osamHistTable OBJECT-TYPE This table represents the information for historical data collected for the osam module. | 1.3.6.1.4.1.4253.2.2.15.1 | not-accessible | mandatory | |
| osamHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.15.1.1 | not-accessible | mandatory | |
| osamHMode OBJECT-TYPE The mode of data collection. | 1.3.6.1.4.1.4253.2.2.15.1.1.1 | HistoryMode | read-only | mandatory |
| osamHNumEvents OBJECT-TYPE Total number of events received for all osam's. | 1.3.6.1.4.1.4253.2.2.15.1.1.2 | Counter | read-only | mandatory |
| osamHHistTable OBJECT-TYPE This table represents the information for historical performance data collected for each osam module. | 1.3.6.1.4.1.4253.2.2.15.2 | not-accessible | mandatory | |
| osamHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.15.2.1 | not-accessible | mandatory | |
| osamHHistMode OBJECT-TYPE The mode of the data collection. | 1.3.6.1.4.1.4253.2.2.15.2.1.1 | HistoryMode | read-only | mandatory |
| osamHHistLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.2.2.15.2.1.2 | CardLocation | read-only | mandatory |
| osamHHistShelf OBJECT-TYPE The shelf number in which the module is plugged in. | 1.3.6.1.4.1.4253.2.2.15.2.1.3 | CardShelf | read-only | mandatory |
| osamHHistSlot OBJECT-TYPE The slot number in which the module is plugged in. | 1.3.6.1.4.1.4253.2.2.15.2.1.4 | INTEGER (1..16) | read-only | mandatory |
| osamHHistLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.2.15.2.1.5 | DateAndTime | read-only | mandatory |
| osamHHistAvailTime OBJECT-TYPE The number of seconds since the start of this historical mode that this module has been up and running. | 1.3.6.1.4.1.4253.2.2.15.2.1.6 | Counter | read-only | mandatory |
| osamHHistErrFreeSecs OBJECT-TYPE The number of seconds since the start of this historical mode that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.15.2.1.7 | Counter | read-only | mandatory |
| rsmHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.16 | |||
| rsmHistTable OBJECT-TYPE This table represents the information for historical data collected for the rsm card | 1.3.6.1.4.1.4253.2.2.16.1 | not-accessible | mandatory | |
| rsmHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.16.1.1 | not-accessible | mandatory | |
| rsmHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.16.1.1.1 | HistoryMode | read-only | mandatory |
| rsmHNumEvents OBJECT-TYPE Total number of all traps (events) generated by all RSM's. | 1.3.6.1.4.1.4253.2.2.16.1.1.2 | Counter | read-only | mandatory |
| rsmHHistTable OBJECT-TYPE This table represents the information for performance data collected for each rsm card. | 1.3.6.1.4.1.4253.2.2.16.2 | not-accessible | mandatory | |
| rsmHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.16.2.1 | not-accessible | mandatory | |
| rsmHHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.16.2.1.1 | HistoryMode | read-only | mandatory |
| rsmHHistLocation OBJECT-TYPE The location of the card. | 1.3.6.1.4.1.4253.2.2.16.2.1.2 | CardLocation | read-only | mandatory |
| rsmHHistShelf OBJECT-TYPE The shelf the card is in. | 1.3.6.1.4.1.4253.2.2.16.2.1.3 | CardShelf | read-only | mandatory |
| rsmHHistSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.2.16.2.1.4 | CardSlot | read-only | mandatory |
| rsmHLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.2.16.2.1.6 | DateAndTime | read-only | mandatory |
| rsmHAvailTime OBJECT-TYPE The number of seconds that this rsm has been up and running. | 1.3.6.1.4.1.4253.2.2.16.2.1.7 | Counter | read-only | mandatory |
| rsmHErrFreeSecs OBJECT-TYPE The number of seconds that this rsm has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.16.2.1.8 | Counter | read-only | mandatory |
| upsmHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.17 | |||
| upsmHistTable OBJECT-TYPE This table represents the information for historical data collected for the upsm card | 1.3.6.1.4.1.4253.2.2.17.1 | not-accessible | mandatory | |
| upsmHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.17.1.1 | not-accessible | mandatory | |
| upsmHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.17.1.1.1 | HistoryMode | read-only | mandatory |
| upsmHNumEvents OBJECT-TYPE Total number of all traps (events) generated by all UPSM's. | 1.3.6.1.4.1.4253.2.2.17.1.1.2 | Counter | read-only | mandatory |
| upsmHHistTable OBJECT-TYPE This table represents the information for performance data collected for each upsm card. | 1.3.6.1.4.1.4253.2.2.17.2 | not-accessible | mandatory | |
| upsmHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.17.2.1 | not-accessible | mandatory | |
| upsmHHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.17.2.1.1 | HistoryMode | read-only | mandatory |
| upsmHHistLocation OBJECT-TYPE The location of the card. | 1.3.6.1.4.1.4253.2.2.17.2.1.2 | CardLocation | read-only | mandatory |
| upsmHHistShelf OBJECT-TYPE The shelf the card is in. | 1.3.6.1.4.1.4253.2.2.17.2.1.3 | CardShelf | read-only | mandatory |
| upsmHHistSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.2.17.2.1.4 | CardSlot | read-only | mandatory |
| upsmHLastBootTime OBJECT-TYPE The date and time of the last boot for this card. | 1.3.6.1.4.1.4253.2.2.17.2.1.6 | DateAndTime | read-only | mandatory |
| upsmHAvailTime OBJECT-TYPE The number of seconds that this upsm has been up and running. | 1.3.6.1.4.1.4253.2.2.17.2.1.7 | Counter | read-only | mandatory |
| upsmHErrFreeSecs OBJECT-TYPE The number of seconds that this upsm has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.17.2.1.8 | Counter | read-only | mandatory |
| mcmescHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.18 | |||
| mcmescHistTable OBJECT-TYPE This table represents the information for historical data collected for the channel card | 1.3.6.1.4.1.4253.2.2.18.1 | not-accessible | mandatory | |
| mcmescHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.18.1.1 | not-accessible | mandatory | |
| mcmescHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or long term. | 1.3.6.1.4.1.4253.2.2.18.1.1.1 | HistoryMode | read-only | mandatory |
| mcmescHNumEvents OBJECT-TYPE Total number of events received for all mcmesc's | 1.3.6.1.4.1.4253.2.2.18.1.1.2 | Counter | read-only | mandatory |
| mcmescHCntrTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.2.18.2 | not-accessible | mandatory | |
| mcmescHCntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.18.2.1 | not-accessible | mandatory | |
| mcmescHCntrMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or long term. | 1.3.6.1.4.1.4253.2.2.18.2.1.1 | HistoryMode | read-only | mandatory |
| mcmescHCntrLocation OBJECT-TYPE The location of the mcmesc card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmesc cards. | 1.3.6.1.4.1.4253.2.2.18.2.1.2 | CardLocation | read-only | mandatory |
| mcmescHCntrShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) mcmesc cards. | 1.3.6.1.4.1.4253.2.2.18.2.1.3 | CardShelf | read-only | mandatory |
| mcmescHCntrSlot OBJECT-TYPE The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmesc cards. | 1.3.6.1.4.1.4253.2.2.18.2.1.4 | CardSlot | read-only | mandatory |
| mcmescHCntrType OBJECT-TYPE The type of the software counter data in this row. The data is collected for the SPI data channels. | 1.3.6.1.4.1.4253.2.2.18.2.1.5 | INTEGER {spi(1), iwm(2)} | read-only | mandatory |
| mcmescHTotPktSent OBJECT-TYPE The number of data packets sent over the given data channel. | 1.3.6.1.4.1.4253.2.2.18.2.1.6 | Counter | read-only | mandatory |
| mcmescHTotPktRcvd OBJECT-TYPE The number of data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.2.18.2.1.7 | Counter | read-only | mandatory |
| mcmescHBadPktRcvd OBJECT-TYPE The number of bad data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.2.18.2.1.8 | Counter | read-only | mandatory |
| mcmescHTotBadTrans OBJECT-TYPE The number of bad data transmissions over the given data channel. | 1.3.6.1.4.1.4253.2.2.18.2.1.9 | Counter | read-only | mandatory |
| mcmescHBytesSent OBJECT-TYPE Total number of bytes sent over the given data channel. | 1.3.6.1.4.1.4253.2.2.18.2.1.10 | Counter | read-only | mandatory |
| mcmescHBytesRcvd OBJECT-TYPE Total number of data bytes received over the given data channel. | 1.3.6.1.4.1.4253.2.2.18.2.1.11 | Counter | read-only | mandatory |
| mcmescHMsgsDlvrd OBJECT-TYPE The number of complete messages delivered over the given data channel. | 1.3.6.1.4.1.4253.2.2.18.2.1.12 | Counter | read-only | mandatory |
| mcmescPortHIntervalTable OBJECT-TYPE This table represents the information for each entry for the mcmesc port counters. | 1.3.6.1.4.1.4253.2.2.18.3 | not-accessible | mandatory | |
| mcmescPortHIntervalEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.18.3.1 | not-accessible | mandatory | |
| mcmescPortHIntervalLocation OBJECT-TYPE The location of the mcmesc card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmesc cards. | 1.3.6.1.4.1.4253.2.2.18.3.1.1 | CardLocation | read-only | mandatory |
| mcmescPortHIntervalShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmesc cards. | 1.3.6.1.4.1.4253.2.2.18.3.1.2 | CardShelf | read-only | mandatory |
| mcmescPortHIntervalSlot OBJECT-TYPE The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmesc cards. | 1.3.6.1.4.1.4253.2.2.18.3.1.3 | CardSlot | read-only | mandatory |
| mcmescPortHIntervalPort OBJECT-TYPE The CPE port within the shelf the card is in. Valid values are: 1 to 12. The system automatically determines the right value for this entry based on the known (available) mcmesc cards. | 1.3.6.1.4.1.4253.2.2.18.3.1.4 | INTEGER | read-only | mandatory |
| mcmescPortHIntervalNumber OBJECT-TYPE The interval number. Valid values are: 1 to 96, where 1 indicates the most recently completed interval. | 1.3.6.1.4.1.4253.2.2.18.3.1.5 | INTEGER | read-only | mandatory |
| mcmescPortHIntervalDuration OBJECT-TYPE MCMESC CPE port's duration, in seconds, for specific interval. The * indicates an incomplete interval resulted from interval setting change. | 1.3.6.1.4.1.4253.2.2.18.3.1.6 | DisplayString | read-only | mandatory |
| mcmescPortHIntervalEns OBJECT-TYPE MCMESC CPE port's enabled seconds for specific interval. | 1.3.6.1.4.1.4253.2.2.18.3.1.7 | DisplayString | read-only | mandatory |
| mcmescPortHIntervalLoss OBJECT-TYPE MCMESC CPE port's loss of signal seconds for specific interval. | 1.3.6.1.4.1.4253.2.2.18.3.1.8 | DisplayString | read-only | mandatory |
| mcmescPortHIntervalCrcErr OBJECT-TYPE MCMESC CPE port's CRC errs counter for specific interval. | 1.3.6.1.4.1.4253.2.2.18.3.1.9 | DisplayString | read-only | mandatory |
| mcmescPortHIntervalOobErr OBJECT-TYPE MCMESC CPE port's Out-of_band error counter for specific interval. | 1.3.6.1.4.1.4253.2.2.18.3.1.10 | DisplayString | read-only | mandatory |
| mcmescPortHIntervalRdpErr OBJECT-TYPE MCMESC CPE port's Running Disparity error counter for specific interval. | 1.3.6.1.4.1.4253.2.2.18.3.1.11 | DisplayString | read-only | mandatory |
| mcmescLinkHIntervalTable OBJECT-TYPE This table represents the information for each entry for the mcmesc port counters. | 1.3.6.1.4.1.4253.2.2.18.4 | not-accessible | mandatory | |
| mcmescLinkHIntervalEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.18.4.1 | not-accessible | mandatory | |
| mcmescLinkHIntervalLocation OBJECT-TYPE The location of the mcmesc card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmesc cards. | 1.3.6.1.4.1.4253.2.2.18.4.1.1 | CardLocation | read-only | mandatory |
| mcmescLinkHIntervalShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) mcmesc cards. | 1.3.6.1.4.1.4253.2.2.18.4.1.2 | CardShelf | read-only | mandatory |
| mcmescLinkHIntervalSlot OBJECT-TYPE The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmesc cards. | 1.3.6.1.4.1.4253.2.2.18.4.1.3 | CardSlot | read-only | mandatory |
| mcmescLinkHIntervalNumber OBJECT-TYPE The interval number. Valid values are: 1 to 96, where 1 indicates the most recently completed interval. | 1.3.6.1.4.1.4253.2.2.18.4.1.4 | INTEGER | read-only | mandatory |
| mcmescLinkHIntervalDuration OBJECT-TYPE MCMESC link port's duration, in seconds, for specific interval. The * indicates an incomplete interval resulted from interval setting change. | 1.3.6.1.4.1.4253.2.2.18.4.1.5 | DisplayString | read-only | mandatory |
| mcmescLinkHIntervalTsos OBJECT-TYPE MCMESC link port's test-sequence on seconds for specific interval. | 1.3.6.1.4.1.4253.2.2.18.4.1.6 | DisplayString | read-only | mandatory |
| mcmescLinkHIntervalLoss OBJECT-TYPE MCMESC link port's loss of signal seconds for specific interval. | 1.3.6.1.4.1.4253.2.2.18.4.1.7 | DisplayString | read-only | mandatory |
| mcmescLinkHIntervalCrcErr OBJECT-TYPE MCMESC link port's CRC errs counter for specific interval. | 1.3.6.1.4.1.4253.2.2.18.4.1.8 | DisplayString | read-only | mandatory |
| mcmescLinkHIntervalOobErr OBJECT-TYPE MCMESC link port's Out-of_band error counter for specific interval. | 1.3.6.1.4.1.4253.2.2.18.4.1.9 | DisplayString | read-only | mandatory |
| mcmescLinkHIntervalRdpErr OBJECT-TYPE MCMESC link port's Running Disparity error counter for specific interval. | 1.3.6.1.4.1.4253.2.2.18.4.1.10 | DisplayString | read-only | mandatory |
| mcmescPortHTotalTable OBJECT-TYPE This table represents the information for each mcmesc cpe port's total counters of up to 96 intervals. | 1.3.6.1.4.1.4253.2.2.18.5 | not-accessible | mandatory | |
| mcmescPortHTotalEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.18.5.1 | not-accessible | mandatory | |
| mcmescPortHTotalCardLocation OBJECT-TYPE Location of the MCMESC CPE port. Valid values are: Local in the same chassis, or remote to this chassis | 1.3.6.1.4.1.4253.2.2.18.5.1.1 | CardLocation | read-only | mandatory |
| mcmescPortHTotalCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1..2. | 1.3.6.1.4.1.4253.2.2.18.5.1.2 | CardShelf | read-only | mandatory |
| mcmescPortHTotalCardSlot OBJECT-TYPE The slot within the shelf the Module is in. | 1.3.6.1.4.1.4253.2.2.18.5.1.3 | CardSlot | read-only | mandatory |
| mcmescPortHTotalPort OBJECT-TYPE CPE port's index. | 1.3.6.1.4.1.4253.2.2.18.5.1.4 | INTEGER | read-only | mandatory |
| mcmescPortHTotalDuration OBJECT-TYPE MCMESC CPE port's total duration of up to 96 intervals. | 1.3.6.1.4.1.4253.2.2.18.5.1.5 | Counter | read-only | mandatory |
| mcmescPortHTotalEns OBJECT-TYPE MCMESC CPE port's total enabled seconds during up to 96 intervals. | 1.3.6.1.4.1.4253.2.2.18.5.1.6 | Counter | read-only | mandatory |
| mcmescPortHTotalLoss OBJECT-TYPE MCMESC CPE port's total loss of signal seconds during up to 96 intervals. | 1.3.6.1.4.1.4253.2.2.18.5.1.7 | Counter | read-only | mandatory |
| mcmescPortHTotalCrcErr OBJECT-TYPE MCMESC CPE port's total CRC error counter during up to 96 intervals. | 1.3.6.1.4.1.4253.2.2.18.5.1.8 | DisplayString | read-only | mandatory |
| mcmescPortHTotalOobErr OBJECT-TYPE MCMESC CPE port's total Out-Of_Band error counter during up to 96 intervals. | 1.3.6.1.4.1.4253.2.2.18.5.1.9 | DisplayString | read-only | mandatory |
| mcmescPortHTotalRdpErr OBJECT-TYPE MCMESC CPE port's total Running Disparity error counter during up to 96 intervals. | 1.3.6.1.4.1.4253.2.2.18.5.1.10 | DisplayString | read-only | mandatory |
| mcmescLinkHTotalTable OBJECT-TYPE This table represents the information for each mcmesc cpe port's total counters of up to 96 intervals. | 1.3.6.1.4.1.4253.2.2.18.6 | not-accessible | mandatory | |
| mcmescLinkHTotalEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.18.6.1 | not-accessible | mandatory | |
| mcmescLinkHTotalCardLocation OBJECT-TYPE Location of the MCMESC link port. Valid values are: Local in the same chassis, or remote to this chassis | 1.3.6.1.4.1.4253.2.2.18.6.1.1 | CardLocation | read-only | mandatory |
| mcmescLinkHTotalCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1..2. | 1.3.6.1.4.1.4253.2.2.18.6.1.2 | CardShelf | read-only | mandatory |
| mcmescLinkHTotalCardSlot OBJECT-TYPE The slot within the shelf the Module is in. | 1.3.6.1.4.1.4253.2.2.18.6.1.3 | CardSlot | read-only | mandatory |
| mcmescLinkHTotalDuration OBJECT-TYPE MCMESC link port's total duration of up to 96 intervals. | 1.3.6.1.4.1.4253.2.2.18.6.1.4 | Counter | read-only | mandatory |
| mcmescLinkHTotalTsos OBJECT-TYPE MCMESC link port's total test-sequence on seconds during up to 96 intervals. | 1.3.6.1.4.1.4253.2.2.18.6.1.5 | Counter | read-only | mandatory |
| mcmescLinkHTotalLoss OBJECT-TYPE MCMESC link port's total loss of signal seconds during up to 96 intervals. | 1.3.6.1.4.1.4253.2.2.18.6.1.6 | Counter | read-only | mandatory |
| mcmescLinkHTotalCrcErr OBJECT-TYPE MCMESC link port's total CRC error counter during up to 96 intervals. | 1.3.6.1.4.1.4253.2.2.18.6.1.7 | DisplayString | read-only | mandatory |
| mcmescLinkHTotalOobErr OBJECT-TYPE MCMESC link port's total Out-Of_Band error counter during up to 96 intervals. | 1.3.6.1.4.1.4253.2.2.18.6.1.8 | DisplayString | read-only | mandatory |
| mcmescLinkHTotalRdpErr OBJECT-TYPE MCMESC link port's total Running Disparity error counter during up to 96 intervals. | 1.3.6.1.4.1.4253.2.2.18.6.1.9 | DisplayString | read-only | mandatory |
| tapHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.19 | |||
| tapHistTable OBJECT-TYPE This table represents the information for historical data collected for the TAP module. | 1.3.6.1.4.1.4253.2.2.19.1 | not-accessible | mandatory | |
| tapHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.19.1.1 | not-accessible | mandatory | |
| tapHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.19.1.1.1 | HistoryMode | read-only | mandatory |
| tapHNumEvents OBJECT-TYPE Total number of all traps (events) generated by all TAP modules. | 1.3.6.1.4.1.4253.2.2.19.1.1.2 | Counter | read-only | mandatory |
| tapHHistTable OBJECT-TYPE This table represents the information for performance data collected for each TAP module | 1.3.6.1.4.1.4253.2.2.19.2 | not-accessible | mandatory | |
| tapHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.19.2.1 | not-accessible | mandatory | |
| tapHHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.19.2.1.1 | HistoryMode | read-only | mandatory |
| tapHHistLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.2.19.2.1.2 | CardLocation | read-only | mandatory |
| tapHHistShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.2.19.2.1.3 | CardShelf | read-only | mandatory |
| tapHHistSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.2.19.2.1.4 | CardSlot | read-only | mandatory |
| tapHHistType OBJECT-TYPE Module type. | 1.3.6.1.4.1.4253.2.2.19.2.1.5 | CardType | read-only | mandatory |
| tapHLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.2.19.2.1.6 | DateAndTime | read-only | mandatory |
| tapHAvailTime OBJECT-TYPE The number of seconds that this module has been up and running. | 1.3.6.1.4.1.4253.2.2.19.2.1.7 | Counter | read-only | mandatory |
| tapHErrFreeSecs OBJECT-TYPE The number of seconds that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.19.2.1.8 | Counter | read-only | mandatory |
| voadmHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.20 | |||
| voadmHistTable OBJECT-TYPE This table represents the information for historical data collected for the VOADM module. | 1.3.6.1.4.1.4253.2.2.20.1 | not-accessible | mandatory | |
| voadmHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.20.1.1 | not-accessible | mandatory | |
| voadmHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.20.1.1.1 | HistoryMode | read-only | mandatory |
| voadmHNumEvents OBJECT-TYPE Total number of all traps (events) generated by all VOADM modules. | 1.3.6.1.4.1.4253.2.2.20.1.1.2 | Counter | read-only | mandatory |
| voadmHHistTable OBJECT-TYPE This table represents the information for performance data collected for each VOADM module | 1.3.6.1.4.1.4253.2.2.20.2 | not-accessible | mandatory | |
| voadmHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.20.2.1 | not-accessible | mandatory | |
| voadmHHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.20.2.1.1 | HistoryMode | read-only | mandatory |
| voadmHHistLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.2.20.2.1.2 | CardLocation | read-only | mandatory |
| voadmHHistShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.2.20.2.1.3 | CardShelf | read-only | mandatory |
| voadmHHistSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.2.20.2.1.4 | CardSlot | read-only | mandatory |
| voadmHHistType OBJECT-TYPE Module type. | 1.3.6.1.4.1.4253.2.2.20.2.1.5 | CardType | read-only | mandatory |
| voadmHLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.2.20.2.1.6 | DateAndTime | read-only | mandatory |
| voadmHAvailTime OBJECT-TYPE The number of seconds that this module has been up and running. | 1.3.6.1.4.1.4253.2.2.20.2.1.7 | Counter | read-only | mandatory |
| voadmHErrFreeSecs OBJECT-TYPE The number of seconds that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.20.2.1.8 | Counter | read-only | mandatory |
| dmmHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.21 | |||
| dmmHistTable OBJECT-TYPE This table represents the information for historical data collected for the DMM module. | 1.3.6.1.4.1.4253.2.2.21.1 | not-accessible | mandatory | |
| dmmHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.21.1.1 | not-accessible | mandatory | |
| dmmHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.21.1.1.1 | HistoryMode | read-only | mandatory |
| dmmHNumEvents OBJECT-TYPE Total number of all traps (events) generated by all DMM modules. | 1.3.6.1.4.1.4253.2.2.21.1.1.2 | Counter | read-only | mandatory |
| dmmHHistTable OBJECT-TYPE This table represents the information for performance data collected for each DMM module | 1.3.6.1.4.1.4253.2.2.21.2 | not-accessible | mandatory | |
| dmmHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.21.2.1 | not-accessible | mandatory | |
| dmmHHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.21.2.1.1 | HistoryMode | read-only | mandatory |
| dmmHHistLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.2.21.2.1.2 | CardLocation | read-only | mandatory |
| dmmHHistShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.2.21.2.1.3 | CardShelf | read-only | mandatory |
| dmmHHistSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.2.21.2.1.4 | CardSlot | read-only | mandatory |
| dmmHLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.2.21.2.1.5 | DateAndTime | read-only | mandatory |
| dmmHAvailTime OBJECT-TYPE The number of seconds that this module has been up and running. | 1.3.6.1.4.1.4253.2.2.21.2.1.6 | Counter | read-only | mandatory |
| dmmHErrFreeSecs OBJECT-TYPE The number of seconds that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.21.2.1.7 | Counter | read-only | mandatory |
| ocm10gfHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.22 | |||
| ocm10gfHistTable OBJECT-TYPE This table represents the information for historical data collected for the OCM10GF module. | 1.3.6.1.4.1.4253.2.2.22.1 | not-accessible | mandatory | |
| ocm10gfHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.22.1.1 | not-accessible | mandatory | |
| ocm10gfHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.22.1.1.1 | HistoryMode | read-only | mandatory |
| ocm10gfHNumEvents OBJECT-TYPE Total number of all traps (events) generated by all OCM10GF modules. | 1.3.6.1.4.1.4253.2.2.22.1.1.2 | Counter | read-only | mandatory |
| ocm10gfHHistTable OBJECT-TYPE This table represents the information for performance data collected for each OCM10GF module | 1.3.6.1.4.1.4253.2.2.22.2 | not-accessible | mandatory | |
| ocm10gfHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.22.2.1 | not-accessible | mandatory | |
| ocm10gfHHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.22.2.1.1 | HistoryMode | read-only | mandatory |
| ocm10gfHHistLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.2.22.2.1.2 | CardLocation | read-only | mandatory |
| ocm10gfHHistShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.2.22.2.1.3 | CardShelf | read-only | mandatory |
| ocm10gfHHistSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.2.22.2.1.4 | CardSlot | read-only | mandatory |
| ocm10gfHLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.2.22.2.1.5 | DateAndTime | read-only | mandatory |
| ocm10gfHAvailTime OBJECT-TYPE The number of seconds that this module has been up and running. | 1.3.6.1.4.1.4253.2.2.22.2.1.6 | Counter | read-only | mandatory |
| ocm10gfHErrFreeSecs OBJECT-TYPE The number of seconds that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.22.2.1.7 | Counter | read-only | mandatory |
| ocm2Hist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.23 | |||
| ocm2HistTable OBJECT-TYPE This table represents the information for historical data collected for the OCM2 module. | 1.3.6.1.4.1.4253.2.2.23.1 | not-accessible | mandatory | |
| ocm2HistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.23.1.1 | not-accessible | mandatory | |
| ocm2HMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.23.1.1.1 | HistoryMode | read-only | mandatory |
| ocm2HNumEvents OBJECT-TYPE Total number of all traps (events) generated by all OCM2 modules. | 1.3.6.1.4.1.4253.2.2.23.1.1.2 | Counter | read-only | mandatory |
| ocm2HHistTable OBJECT-TYPE This table represents the information for performance data collected for each OCM2 module | 1.3.6.1.4.1.4253.2.2.23.2 | not-accessible | mandatory | |
| ocm2HHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.23.2.1 | not-accessible | mandatory | |
| ocm2HHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.23.2.1.1 | HistoryMode | read-only | mandatory |
| ocm2HHistLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.2.23.2.1.2 | CardLocation | read-only | mandatory |
| ocm2HHistShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.2.23.2.1.3 | CardShelf | read-only | mandatory |
| ocm2HHistSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.2.23.2.1.4 | CardSlot | read-only | mandatory |
| ocm2HLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.2.23.2.1.5 | DateAndTime | read-only | mandatory |
| ocm2HAvailTime OBJECT-TYPE The number of seconds that this module has been up and running. | 1.3.6.1.4.1.4253.2.2.23.2.1.6 | Counter | read-only | mandatory |
| ocm2HErrFreeSecs OBJECT-TYPE The number of seconds that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.23.2.1.7 | Counter | read-only | mandatory |
| oscHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.24 | |||
| oscHistTable OBJECT-TYPE This table represents the information for historical data collected for the OSC module. | 1.3.6.1.4.1.4253.2.2.24.1 | not-accessible | mandatory | |
| oscHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.24.1.1 | not-accessible | mandatory | |
| oscHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.24.1.1.1 | HistoryMode | read-only | mandatory |
| oscHNumEvents OBJECT-TYPE Total number of all traps (events) generated by all OSC modules. | 1.3.6.1.4.1.4253.2.2.24.1.1.2 | Counter | read-only | mandatory |
| oscHHistTable OBJECT-TYPE This table represents the information for performance data collected for each OSC module | 1.3.6.1.4.1.4253.2.2.24.2 | not-accessible | mandatory | |
| oscHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.24.2.1 | not-accessible | mandatory | |
| oscHHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.24.2.1.1 | HistoryMode | read-only | mandatory |
| oscHHistLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.2.24.2.1.2 | CardLocation | read-only | mandatory |
| oscHHistShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.2.24.2.1.3 | CardShelf | read-only | mandatory |
| oscHHistSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.2.24.2.1.4 | CardSlot | read-only | mandatory |
| oscHLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.2.24.2.1.5 | DateAndTime | read-only | mandatory |
| oscHAvailTime OBJECT-TYPE The number of seconds that this module has been up and running. | 1.3.6.1.4.1.4253.2.2.24.2.1.6 | Counter | read-only | mandatory |
| oscHErrFreeSecs OBJECT-TYPE The number of seconds that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.24.2.1.7 | Counter | read-only | mandatory |
| ocm4gHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.25 | |||
| ocm4gHistTable OBJECT-TYPE This table represents the information for historical data collected for the OCM4G module. | 1.3.6.1.4.1.4253.2.2.25.1 | not-accessible | mandatory | |
| ocm4gHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.25.1.1 | not-accessible | mandatory | |
| ocm4gHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.25.1.1.1 | HistoryMode | read-only | mandatory |
| ocm4gHNumEvents OBJECT-TYPE Total number of all traps (events) generated by all OCM4G modules. | 1.3.6.1.4.1.4253.2.2.25.1.1.2 | Counter | read-only | mandatory |
| ocm4gHHistTable OBJECT-TYPE This table represents the information for performance data collected for each OCM4G module | 1.3.6.1.4.1.4253.2.2.25.2 | not-accessible | mandatory | |
| ocm4gHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.25.2.1 | not-accessible | mandatory | |
| ocm4gHHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.25.2.1.1 | HistoryMode | read-only | mandatory |
| ocm4gHHistLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.2.25.2.1.2 | INTEGER {local(1)} | read-only | mandatory |
| ocm4gHHistShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.2.25.2.1.3 | CardShelf | read-only | mandatory |
| ocm4gHHistSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.2.25.2.1.4 | CardSlot | read-only | mandatory |
| ocm4gHLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.2.25.2.1.5 | DateAndTime | read-only | mandatory |
| ocm4gHAvailTime OBJECT-TYPE The number of seconds that this module has been up and running. | 1.3.6.1.4.1.4253.2.2.25.2.1.6 | Counter | read-only | mandatory |
| ocm4gHErrFreeSecs OBJECT-TYPE The number of seconds that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.25.2.1.7 | Counter | read-only | mandatory |
| oetHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.26 | |||
| uobHist OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.2.27 | |||
| uobHistTable OBJECT-TYPE This table represents the information for historical data collected for the UOB module. | 1.3.6.1.4.1.4253.2.2.27.1 | not-accessible | mandatory | |
| uobHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.27.1.1 | not-accessible | mandatory | |
| uobHMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.27.1.1.1 | HistoryMode | read-only | mandatory |
| uobHNumEvents OBJECT-TYPE Total number of all traps (events) generated by all UOB modules. | 1.3.6.1.4.1.4253.2.2.27.1.1.2 | Counter | read-only | mandatory |
| uobHHistTable OBJECT-TYPE This table represents the information for performance data collected for each UOB module | 1.3.6.1.4.1.4253.2.2.27.2 | not-accessible | mandatory | |
| uobHHistEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.2.27.2.1 | not-accessible | mandatory | |
| uobHHistMode OBJECT-TYPE The mode of the data collection. Valid values are: daily or longterm. | 1.3.6.1.4.1.4253.2.2.27.2.1.1 | HistoryMode | read-only | mandatory |
| uobHHistLocation OBJECT-TYPE The location of the module. Choices are local or remote. | 1.3.6.1.4.1.4253.2.2.27.2.1.2 | CardLocation | read-only | mandatory |
| uobHHistShelf OBJECT-TYPE The shelf the module is in. | 1.3.6.1.4.1.4253.2.2.27.2.1.3 | CardShelf | read-only | mandatory |
| uobHHistSlot OBJECT-TYPE The slot within the shelf the module is in. | 1.3.6.1.4.1.4253.2.2.27.2.1.4 | CardSlot | read-only | mandatory |
| uobHLastBootTime OBJECT-TYPE The date and time of the last boot for this module. | 1.3.6.1.4.1.4253.2.2.27.2.1.5 | DateAndTime | read-only | mandatory |
| uobHAvailTime OBJECT-TYPE The number of seconds that this module has been up and running. | 1.3.6.1.4.1.4253.2.2.27.2.1.6 | Counter | read-only | mandatory |
| uobHErrFreeSecs OBJECT-TYPE The number of seconds that this module has not experienced any alarms. | 1.3.6.1.4.1.4253.2.2.27.2.1.7 | Counter | read-only | mandatory |
| specialConditions OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.3 | |||
| systemCond OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.3.1 | |||
| sysCStatus OBJECT-TYPE The global status of the system as computed based on the traps (events) that are generated. Choices are: Critical, Major, Minor or Normal. | 1.3.6.1.4.1.4253.2.3.1.1 | CardStatus | not-accessible | mandatory |
| sysCSetMode OBJECT-TYPE If on, the special conditions counters will be activated. These counters continue counting until the mode is off. On startup, this flag is off. | 1.3.6.1.4.1.4253.2.3.1.2 | FlagType | not-accessible | mandatory |
| sysCAvailTime OBJECT-TYPE The number of seconds since this mode is started that the system has been up and running. The Criteria for the system available time is having at least one CP running with atmost non-service affecting minor alarm system status | 1.3.6.1.4.1.4253.2.3.1.3 | Counter | not-accessible | mandatory |
| sysCErrFreeSecs OBJECT-TYPE The number of seconds since this mode is started that the device has not experienced any alarms. This counter is across all cards in the chassis. The system must be in Normal status for this counter to be incremented. | 1.3.6.1.4.1.4253.2.3.1.4 | Counter | not-accessible | mandatory |
| downloadCond OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.3.2 | |||
| dlCStatus OBJECT-TYPE The global status of the download task. The download task (download to the device) is either ftp-inprogress, module update inprogress or currently idle. Since only one download at the time is handled by the system, this flag is set to inprogress as soon as any download starts. It is reset back to idle when the download is completed. This flag is set to idle on system startup. This flag can be remotely set to idle if a previous FTP download was interrupted. | 1.3.6.1.4.1.4253.2.3.2.1 | DownloadStatus | not-accessible | mandatory |
| dlCOkDownloads OBJECT-TYPE The number of successful downloads in this time interval (15 minutes). | 1.3.6.1.4.1.4253.2.3.2.2 | Counter | not-accessible | mandatory |
| dlCBadDownloads OBJECT-TYPE The number of failed downloads in this time interval (15 minutes). | 1.3.6.1.4.1.4253.2.3.2.3 | Counter | not-accessible | mandatory |
| dlCLongestTime OBJECT-TYPE Longest time for any download, in seconds, in this time interval (15 minutes). | 1.3.6.1.4.1.4253.2.3.2.4 | Gauge | not-accessible | mandatory |
| dlCLongestSize OBJECT-TYPE Longest download size for any download, in bytes, in this time interval (15 minutes). | 1.3.6.1.4.1.4253.2.3.2.5 | Gauge | not-accessible | mandatory |
| dlCCounterFlag OBJECT-TYPE Turns software counters On or Off. | 1.3.6.1.4.1.4253.2.3.2.6 | FlagType | not-accessible | mandatory |
| cpCond OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.3.3 | |||
| cpCNumEvents OBJECT-TYPE Total number of events received by the active CP since this mode was activated. | 1.3.6.1.4.1.4253.2.3.3.1 | Counter | not-accessible | mandatory |
| cpCTrapsSent OBJECT-TYPE Total number of traps sent by the active CP since this mode was activated. | 1.3.6.1.4.1.4253.2.3.3.2 | Counter | not-accessible | mandatory |
| cpCSNMPCmdsRcvd OBJECT-TYPE Total number of SNMP commands received by the active CP since this mode was activated. | 1.3.6.1.4.1.4253.2.3.3.3 | Counter | not-accessible | mandatory |
| cpCCounterFlag OBJECT-TYPE Turns software counters On or Off. | 1.3.6.1.4.1.4253.2.3.3.4 | FlagType | not-accessible | mandatory |
| cpCCntrTable OBJECT-TYPE This table represents the information for each entry for the software counters. It is only applicable to the active MPM card. | 1.3.6.1.4.1.4253.2.3.3.5 | not-accessible | mandatory | |
| cpCCntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.3.5.1 | not-accessible | mandatory | |
| cpCCntrShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10. The system automatically determines the right value for this entry based on the value of the current active CP card. | 1.3.6.1.4.1.4253.2.3.3.5.1.1 | CardShelf | not-accessible | mandatory |
| cpCCntrSlot OBJECT-TYPE The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the value of the current active CP card. | 1.3.6.1.4.1.4253.2.3.3.5.1.2 | CardSlot | not-accessible | mandatory |
| cpCCntrType OBJECT-TYPE The type of the software counter data in this row. The data is collected for the SPI data channels. | 1.3.6.1.4.1.4253.2.3.3.5.1.3 | INTEGER {spi(1)} | not-accessible | mandatory |
| cpCTotPktSent OBJECT-TYPE The number of data packets sent over the given data channel. | 1.3.6.1.4.1.4253.2.3.3.5.1.4 | Counter | not-accessible | mandatory |
| cpCTotPktRcvd OBJECT-TYPE The number of data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.3.3.5.1.5 | Counter | not-accessible | mandatory |
| cpCBadPktRcvd OBJECT-TYPE The number of bad data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.3.3.5.1.6 | Counter | not-accessible | mandatory |
| cpCTotBadTrans OBJECT-TYPE The number of bad data transmissions over the given data channel. | 1.3.6.1.4.1.4253.2.3.3.5.1.7 | Counter | not-accessible | mandatory |
| cpCBytesSent OBJECT-TYPE Total number of bytes sent over the given data channel. | 1.3.6.1.4.1.4253.2.3.3.5.1.8 | Counter | not-accessible | mandatory |
| cpCBytesRcvd OBJECT-TYPE Total number of data bytes received over the given data channel. | 1.3.6.1.4.1.4253.2.3.3.5.1.9 | Counter | not-accessible | mandatory |
| cpCMsgsDlvrd OBJECT-TYPE The number of complete messages delivered over the given data channel. | 1.3.6.1.4.1.4253.2.3.3.5.1.10 | Counter | not-accessible | mandatory |
| cpCBufAllocFail OBJECT-TYPE Number of buffer allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.3.3.5.1.11 | Counter | not-accessible | mandatory |
| cpCEcbAllocFail OBJECT-TYPE Number of Event Control Block allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.3.3.5.1.12 | Counter | not-accessible | mandatory |
| cpCPerfTable OBJECT-TYPE This table represents the information for performance data collected for each communication processor | 1.3.6.1.4.1.4253.2.3.3.6 | not-accessible | mandatory | |
| cpCPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.3.6.1 | not-accessible | mandatory | |
| cpCPerfShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.3.3.6.1.1 | CardShelf | not-accessible | mandatory |
| cpCPerfSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.3.3.6.1.2 | CardSlot | not-accessible | mandatory |
| cpCPerfMode OBJECT-TYPE The valid types are: active CP or standby CP | 1.3.6.1.4.1.4253.2.3.3.6.1.3 | RedundancyMode | not-accessible | mandatory |
| cpCPerfState OBJECT-TYPE The state of the communication card. The states are: online, offline, empty, loopback or diagnostics. | 1.3.6.1.4.1.4253.2.3.3.6.1.4 | CardState | not-accessible | mandatory |
| cpCPerfStatus OBJECT-TYPE The status of the communication processor. This status represents the state of the communication processor and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.3.3.6.1.5 | CardStatus | not-accessible | mandatory |
| cpCAvailTime OBJECT-TYPE The number of seconds since this mode is started that this CP has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.3.3.6.1.7 | Counter | not-accessible | mandatory |
| cpCErrFreeSecs OBJECT-TYPE The number of seconds since this mode is started that this CP has not experienced any alarms. | 1.3.6.1.4.1.4253.2.3.3.6.1.8 | Counter | not-accessible | mandatory |
| ccCond OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.3.4 | |||
| ccCNumEvents OBJECT-TYPE Total number of events received for all CC's since this mode was started. | 1.3.6.1.4.1.4253.2.3.4.1 | Counter | not-accessible | mandatory |
| ccCCntrTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.3.4.2 | not-accessible | mandatory | |
| ccCCntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.4.2.1 | not-accessible | mandatory | |
| ccCCntrLocation OBJECT-TYPE The location of the CC card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known CC cards. | 1.3.6.1.4.1.4253.2.3.4.2.1.1 | CardLocation | not-accessible | mandatory |
| ccCCntrShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10. The system automatically determines the right value for this entry based on the known (available) CC cards. | 1.3.6.1.4.1.4253.2.3.4.2.1.2 | CardShelf | not-accessible | mandatory |
| ccCCntrSlot OBJECT-TYPE The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) CC cards. | 1.3.6.1.4.1.4253.2.3.4.2.1.3 | CardSlot | not-accessible | mandatory |
| ccCCntrType OBJECT-TYPE The type of the software counter data in this row. The data is collected for the SPI data channels. | 1.3.6.1.4.1.4253.2.3.4.2.1.4 | INTEGER {spi(1), iwm(2)} | not-accessible | mandatory |
| ccCCounterFlag OBJECT-TYPE Turns software counters, both On or both Off for this CC. When Off Clears both counters Statistic information | 1.3.6.1.4.1.4253.2.3.4.2.1.5 | FlagType | not-accessible | mandatory |
| ccCTotPktSent OBJECT-TYPE The number of data packets sent over the given data channel. | 1.3.6.1.4.1.4253.2.3.4.2.1.6 | Counter | not-accessible | mandatory |
| ccCTotPktRcvd OBJECT-TYPE The number of data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.3.4.2.1.7 | Counter | not-accessible | mandatory |
| ccCBadPktRcvd OBJECT-TYPE The number of bad data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.3.4.2.1.8 | Counter | not-accessible | mandatory |
| ccCTotBadTrans OBJECT-TYPE The number of bad data transmissions over the given data channel. | 1.3.6.1.4.1.4253.2.3.4.2.1.9 | Counter | not-accessible | mandatory |
| ccCBytesSent OBJECT-TYPE Total number of bytes sent over the given data channel. | 1.3.6.1.4.1.4253.2.3.4.2.1.10 | Counter | not-accessible | mandatory |
| ccCBytesRcvd OBJECT-TYPE Total number of data bytes received over the given data channel. | 1.3.6.1.4.1.4253.2.3.4.2.1.11 | Counter | not-accessible | mandatory |
| ccCMsgsDlvrd OBJECT-TYPE The number of complete messages delivered over the given data channel. | 1.3.6.1.4.1.4253.2.3.4.2.1.12 | Counter | not-accessible | mandatory |
| ccCBufAllocFail OBJECT-TYPE Number of buffer allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.3.4.2.1.13 | Counter | not-accessible | mandatory |
| ccCEcbAllocFail OBJECT-TYPE Number of Event Control Block allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.3.4.2.1.14 | Counter | not-accessible | mandatory |
| ccCClearCntrs OBJECT-TYPE If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other. | 1.3.6.1.4.1.4253.2.3.4.2.1.15 | ResetType | not-accessible | mandatory |
| ccCPerfTable OBJECT-TYPE This table represents the information for performance data collected for each channel card. | 1.3.6.1.4.1.4253.2.3.4.3 | not-accessible | mandatory | |
| ccCPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.4.3.1 | not-accessible | mandatory | |
| ccCPerfLocation OBJECT-TYPE The location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) CC cards. | 1.3.6.1.4.1.4253.2.3.4.3.1.1 | CardLocation | not-accessible | mandatory |
| ccCPerfShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.3.4.3.1.2 | CardShelf | not-accessible | mandatory |
| ccCPerfSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.3.4.3.1.3 | CardSlot | not-accessible | mandatory |
| ccCPerfState OBJECT-TYPE The state of the channel card. The states' are: online, offline, empty, loopback or diagnostics. | 1.3.6.1.4.1.4253.2.3.4.3.1.4 | CardState | not-accessible | mandatory |
| ccCPerfStatus OBJECT-TYPE The status of the channel card. This status represents the status of the communication processor and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.3.4.3.1.5 | CardStatus | not-accessible | mandatory |
| ccCAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this CC has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.3.4.3.1.6 | Counter | not-accessible | mandatory |
| ccCErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this CC has not experienced any alarms. | 1.3.6.1.4.1.4253.2.3.4.3.1.7 | Counter | not-accessible | mandatory |
| ccCBiasCurrent OBJECT-TYPE Bias current for the optical laser. | 1.3.6.1.4.1.4253.2.3.4.3.1.8 | INTEGER | not-accessible | mandatory |
| ccCModulation OBJECT-TYPE The frequency modulation for the optical laser. | 1.3.6.1.4.1.4253.2.3.4.3.1.9 | INTEGER | not-accessible | mandatory |
| ccCApc OBJECT-TYPE The APC value. | 1.3.6.1.4.1.4253.2.3.4.3.1.10 | INTEGER | not-accessible | mandatory |
| ccCIwmModulation OBJECT-TYPE The frequency modulation for the IWM channel. | 1.3.6.1.4.1.4253.2.3.4.3.1.11 | INTEGER | not-accessible | mandatory |
| ccCLaserOnOff OBJECT-TYPE The laser On/Off flag. | 1.3.6.1.4.1.4253.2.3.4.3.1.12 | FlagType | not-accessible | mandatory |
| ccCTemperature OBJECT-TYPE The current temperature, or the operating temperature of the optical device. | 1.3.6.1.4.1.4253.2.3.4.3.1.13 | Gauge | not-accessible | mandatory |
| ccCIntensity OBJECT-TYPE The intensity of the optical light. | 1.3.6.1.4.1.4253.2.3.4.3.1.14 | Gauge | not-accessible | mandatory |
| ccCSignalStrength OBJECT-TYPE The current signal strength for the optical path. | 1.3.6.1.4.1.4253.2.3.4.3.1.15 | Gauge | not-accessible | mandatory |
| ccCLossOfLight OBJECT-TYPE If set to true, no laser light is present. If set to false, no loss of light has occurred. | 1.3.6.1.4.1.4253.2.3.4.3.1.16 | Boolean | not-accessible | mandatory |
| ccCSignalDetect OBJECT-TYPE If set to true, signal is detected. If set to false, no signal is present. | 1.3.6.1.4.1.4253.2.3.4.3.1.17 | Boolean | not-accessible | mandatory |
| ccCRefClock OBJECT-TYPE The value of the reference clock in decimal notation. For a given value, like 1660, the actual value is 16.60-EN. In otherwords, assume a two digit decimal point, plus any appropriate scaling factor. | 1.3.6.1.4.1.4253.2.3.4.3.1.18 | INTEGER {en1660(1), en1944(2), en1953(3)} | not-accessible | mandatory |
| ccCClockDiv OBJECT-TYPE The clock divisor. Values are 1250, 622 or 155 in the appropriate clock frequency scale. | 1.3.6.1.4.1.4253.2.3.4.3.1.19 | INTEGER {dout-1250(1), dout-622(2), dout-155(3)} | not-accessible | mandatory |
| ccCProtectionMode OBJECT-TYPE UPSR Protection Mode: active, standby and na. | 1.3.6.1.4.1.4253.2.3.4.3.1.20 | INTEGER {active(1), standby(2), na(3)} | not-accessible | mandatory |
| muxCond OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.3.5 | |||
| muxCNumEvents OBJECT-TYPE Total number of all traps (events) generated by all MUX's since this mode is started. | 1.3.6.1.4.1.4253.2.3.5.1 | Counter | not-accessible | mandatory |
| muxCPerfTable OBJECT-TYPE This table represents the information for performance data collected for each mux/demux card | 1.3.6.1.4.1.4253.2.3.5.2 | not-accessible | mandatory | |
| muxCPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.5.2.1 | not-accessible | mandatory | |
| muxCPerfLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.3.5.2.1.1 | CardLocation | not-accessible | mandatory |
| muxCPerfShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.3.5.2.1.2 | CardShelf | not-accessible | mandatory |
| muxCPerfSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.3.5.2.1.3 | CardSlot | not-accessible | mandatory |
| muxCType OBJECT-TYPE The type of the mux. The choices are: mux or demux. | 1.3.6.1.4.1.4253.2.3.5.2.1.4 | INTEGER {mux(4), demux(5), w4cd(10), w2cmd(13), w4cm(21)} | not-accessible | mandatory |
| muxCPerfState OBJECT-TYPE The status of the mux card. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.3.5.2.1.5 | CardState | not-accessible | mandatory |
| muxCPerfStatus OBJECT-TYPE The status of the mux card. This status represents the status of the mux card and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.3.5.2.1.6 | CardStatus | not-accessible | mandatory |
| muxCAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this Mux has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.3.5.2.1.7 | Counter | not-accessible | mandatory |
| muxCErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this mux has not experienced any alarms. | 1.3.6.1.4.1.4253.2.3.5.2.1.8 | Counter | not-accessible | mandatory |
| muxCCounterFlag OBJECT-TYPE Turns special condition software counters On or Off for this card. Default is off. | 1.3.6.1.4.1.4253.2.3.5.3 | FlagType | not-accessible | mandatory |
| psCond OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.3.6 | |||
| psCNumEvents OBJECT-TYPE Total number of all traps (events) generated by all Power Supplies since this mode is started. | 1.3.6.1.4.1.4253.2.3.6.1 | Counter | not-accessible | mandatory |
| psCVoltageLevel3pt3Volt OBJECT-TYPE Voltage Level of the 3.3 V power supply. Need to divide this value by ten to get the actual voltage level. | 1.3.6.1.4.1.4253.2.3.6.2 | INTEGER | not-accessible | mandatory |
| psCVoltageLevel5Volt OBJECT-TYPE Voltage Level of the 5 V power supply. Need to divide this value by ten to get the actual voltage level. | 1.3.6.1.4.1.4253.2.3.6.3 | INTEGER | not-accessible | mandatory |
| psCVoltageLevel12Volt OBJECT-TYPE Voltage Level of the 12 V power supply. Need to divide this value by ten to get the actual voltage level. | 1.3.6.1.4.1.4253.2.3.6.4 | INTEGER | not-accessible | mandatory |
| psCPerfTable OBJECT-TYPE This table represents the information for performance data collected for each power supply card | 1.3.6.1.4.1.4253.2.3.6.5 | not-accessible | mandatory | |
| psCPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.6.5.1 | not-accessible | mandatory | |
| psCPerfID OBJECT-TYPE The module id where ps is in. Valid values are: 1 to 4 | 1.3.6.1.4.1.4253.2.3.6.5.1.1 | INTEGER | not-accessible | mandatory |
| psCPerfType OBJECT-TYPE The type of the power supply card. The choices are: active (primary PS) or standby. | 1.3.6.1.4.1.4253.2.3.6.5.1.2 | RedundancyMode | not-accessible | mandatory |
| psCPerfState OBJECT-TYPE The state of the power supply card. The states are: online, offline, empty, loopback or diagnostics. | 1.3.6.1.4.1.4253.2.3.6.5.1.3 | CardState | not-accessible | mandatory |
| psCPerfStatus OBJECT-TYPE The status of the power supply card. This status represents the status of the ps card and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.3.6.5.1.4 | CardStatus | not-accessible | mandatory |
| fadmCond OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.3.7 | |||
| fadmCNumEvents OBJECT-TYPE Total number of all traps (events) generated by all FADM's since this mode is started. | 1.3.6.1.4.1.4253.2.3.7.1 | Counter | not-accessible | mandatory |
| fadmCCounterFlag OBJECT-TYPE Turns software counters On or Off for this FADM. | 1.3.6.1.4.1.4253.2.3.7.2 | FlagType | not-accessible | mandatory |
| fadmCPerfTable OBJECT-TYPE This table represents the information for performance data collected for each fadm card | 1.3.6.1.4.1.4253.2.3.7.3 | not-accessible | mandatory | |
| fadmCPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.7.3.1 | not-accessible | mandatory | |
| fadmCPerfLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.3.7.3.1.1 | CardLocation | not-accessible | mandatory |
| fadmCPerfShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.3.7.3.1.2 | CardShelf | not-accessible | mandatory |
| fadmCPerfSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.3.7.3.1.3 | CardSlot | not-accessible | mandatory |
| fadmCPerfState OBJECT-TYPE The status of the mux card. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.3.7.3.1.5 | CardState | not-accessible | mandatory |
| fadmCPerfStatus OBJECT-TYPE The status of the mux card. This status represents the status of the mux card and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.3.7.3.1.6 | CardStatus | not-accessible | mandatory |
| fadmCAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this Mux has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.3.7.3.1.7 | Counter | not-accessible | mandatory |
| fadmCErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this mux has not experienced any alarms. | 1.3.6.1.4.1.4253.2.3.7.3.1.8 | Counter | not-accessible | mandatory |
| oppmCond OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.3.8 | |||
| oppmCNumEvents OBJECT-TYPE Total number of all traps (events) generated by all OPPMs' since this mode is started. | 1.3.6.1.4.1.4253.2.3.8.1 | Counter | not-accessible | mandatory |
| oppmCPerfTable OBJECT-TYPE This table represents the information for performance data collected for each oppm card | 1.3.6.1.4.1.4253.2.3.8.2 | not-accessible | mandatory | |
| oppmCPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.8.2.1 | not-accessible | mandatory | |
| oppmCPerfLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.3.8.2.1.1 | CardLocation | not-accessible | mandatory |
| oppmCPerfShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.3.8.2.1.2 | CardShelf | not-accessible | mandatory |
| oppmCPerfSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.3.8.2.1.3 | CardSlot | not-accessible | mandatory |
| oppmCPerfState OBJECT-TYPE The status of the oppm card. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.3.8.2.1.4 | CardState | not-accessible | mandatory |
| oppmCPerfStatus OBJECT-TYPE The status of the oppm card. This status represents the status of the oppm card and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.3.8.2.1.5 | CardStatus | not-accessible | mandatory |
| oppmCAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this oppm has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.3.8.2.1.6 | Counter | not-accessible | mandatory |
| oppmCErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this oppm has not experienced any alarms. | 1.3.6.1.4.1.4253.2.3.8.2.1.7 | Counter | not-accessible | mandatory |
| oppmCCounterFlag OBJECT-TYPE Turns special condition software counters On or Off for this card. Default is off. | 1.3.6.1.4.1.4253.2.3.8.3 | FlagType | not-accessible | mandatory |
| mcmCond OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.3.9 | |||
| mcmCNumEvents OBJECT-TYPE Total number of events received for all MCM's since this mode was started. | 1.3.6.1.4.1.4253.2.3.9.1 | Counter | not-accessible | mandatory |
| mcmCCntrTable OBJECT-TYPE This table represents the information for each entry for the software counters. | 1.3.6.1.4.1.4253.2.3.9.2 | not-accessible | mandatory | |
| mcmCCntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.9.2.1 | not-accessible | mandatory | |
| mcmCCntrLocation OBJECT-TYPE The location of the MCM card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known MCM cards. | 1.3.6.1.4.1.4253.2.3.9.2.1.1 | CardLocation | not-accessible | mandatory |
| mcmCCntrShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10. The system automatically determines the right value for this entry based on the known (available) MCM cards. | 1.3.6.1.4.1.4253.2.3.9.2.1.2 | CardShelf | not-accessible | mandatory |
| mcmCCntrSlot OBJECT-TYPE The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) MCM cards. | 1.3.6.1.4.1.4253.2.3.9.2.1.3 | CardSlot | not-accessible | mandatory |
| mcmCCntrType OBJECT-TYPE The type of the software counter data in this row. The data is collected for the SPI data channels. | 1.3.6.1.4.1.4253.2.3.9.2.1.4 | INTEGER {spi(1), iwm(2)} | not-accessible | mandatory |
| mcmCCounterFlag OBJECT-TYPE Turns software counters On or Off for this MCM. | 1.3.6.1.4.1.4253.2.3.9.2.1.5 | FlagType | not-accessible | mandatory |
| mcmCTotPktSent OBJECT-TYPE The number of data packets sent over the given data channel. | 1.3.6.1.4.1.4253.2.3.9.2.1.6 | Counter | not-accessible | mandatory |
| mcmCTotPktRcvd OBJECT-TYPE The number of data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.3.9.2.1.7 | Counter | not-accessible | mandatory |
| mcmCBadPktRcvd OBJECT-TYPE The number of bad data packets received over the given data channel. | 1.3.6.1.4.1.4253.2.3.9.2.1.8 | Counter | not-accessible | mandatory |
| mcmCTotBadTrans OBJECT-TYPE The number of bad data transmissions over the given data channel. | 1.3.6.1.4.1.4253.2.3.9.2.1.9 | Counter | not-accessible | mandatory |
| mcmCBytesSent OBJECT-TYPE Total number of bytes sent over the given data channel. | 1.3.6.1.4.1.4253.2.3.9.2.1.10 | Counter | not-accessible | mandatory |
| mcmCBytesRcvd OBJECT-TYPE Total number of data bytes received over the given data channel. | 1.3.6.1.4.1.4253.2.3.9.2.1.11 | Counter | not-accessible | mandatory |
| mcmCMsgsDlvrd OBJECT-TYPE The number of complete messages delivered over the given data channel. | 1.3.6.1.4.1.4253.2.3.9.2.1.12 | Counter | not-accessible | mandatory |
| mcmCBufAllocFail OBJECT-TYPE Number of buffer allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.3.9.2.1.13 | Counter | not-accessible | mandatory |
| mcmCEcbAllocFail OBJECT-TYPE Number of Event Control Block allocation failures for the given data channel. | 1.3.6.1.4.1.4253.2.3.9.2.1.14 | Counter | not-accessible | mandatory |
| mcmCClearCntrs OBJECT-TYPE If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other. | 1.3.6.1.4.1.4253.2.3.9.2.1.15 | ResetType | not-accessible | mandatory |
| mcmCPerfTable OBJECT-TYPE This table represents the information for performance data collected for each channel card | 1.3.6.1.4.1.4253.2.3.9.3 | not-accessible | mandatory | |
| mcmCPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.9.3.1 | not-accessible | mandatory | |
| mcmCPerfLocation OBJECT-TYPE The location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) CC cards. | 1.3.6.1.4.1.4253.2.3.9.3.1.1 | CardLocation | not-accessible | mandatory |
| mcmCPerfShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.3.9.3.1.2 | CardShelf | not-accessible | mandatory |
| mcmCPerfSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.3.9.3.1.3 | CardSlot | not-accessible | mandatory |
| mcmCPerfState OBJECT-TYPE The state of the channel card. The states' are: online, offline, empty, loopback or diagnostics. | 1.3.6.1.4.1.4253.2.3.9.3.1.4 | CardState | not-accessible | mandatory |
| mcmCPerfStatus OBJECT-TYPE The status of the channel card. This status represents the status of the communication processor and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.3.9.3.1.5 | CardStatus | not-accessible | mandatory |
| mcmCAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this CC has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.3.9.3.1.6 | Counter | not-accessible | mandatory |
| mcmCErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this MCM has not experienced any alarms. | 1.3.6.1.4.1.4253.2.3.9.3.1.7 | Counter | not-accessible | mandatory |
| mcmCBiasCurrent OBJECT-TYPE Bias current for the optical laser. | 1.3.6.1.4.1.4253.2.3.9.3.1.8 | INTEGER | not-accessible | mandatory |
| mcmCModulation OBJECT-TYPE The frequency modulation for the optical laser. | 1.3.6.1.4.1.4253.2.3.9.3.1.9 | INTEGER | not-accessible | mandatory |
| mcmCApc OBJECT-TYPE The APC value. | 1.3.6.1.4.1.4253.2.3.9.3.1.10 | INTEGER | not-accessible | mandatory |
| mcmCIwmModulation OBJECT-TYPE The frequency modulation for the IWM channel. | 1.3.6.1.4.1.4253.2.3.9.3.1.11 | INTEGER | not-accessible | mandatory |
| mcmCLaserOnOff OBJECT-TYPE The laser On/Off flag. | 1.3.6.1.4.1.4253.2.3.9.3.1.12 | FlagType | not-accessible | mandatory |
| mcmCTemperature OBJECT-TYPE The current temperature, or the operating temperature of the optical device. | 1.3.6.1.4.1.4253.2.3.9.3.1.13 | Gauge | not-accessible | mandatory |
| mcmCIntensity OBJECT-TYPE The intensity of the optical light. | 1.3.6.1.4.1.4253.2.3.9.3.1.14 | Gauge | not-accessible | mandatory |
| mcmCSignalStrength OBJECT-TYPE The current signal strength for the optical path. | 1.3.6.1.4.1.4253.2.3.9.3.1.15 | Gauge | not-accessible | mandatory |
| mcmCLossOfLight OBJECT-TYPE If set to true, no laser light is present. If set to false, no loss of light has occurred. | 1.3.6.1.4.1.4253.2.3.9.3.1.16 | Boolean | not-accessible | mandatory |
| mcmCSignalDetect OBJECT-TYPE If set to true, signal is detected. If set to false, no signal is present. | 1.3.6.1.4.1.4253.2.3.9.3.1.17 | Boolean | not-accessible | mandatory |
| mcmCRefClock OBJECT-TYPE The value of the reference clock in decimal notation. For a given value, like 1660, the actual value is 16.60-EN. In otherwords, assume a two digit decimal point, plus any appropriate scaling factor. | 1.3.6.1.4.1.4253.2.3.9.3.1.18 | INTEGER {en1660(1), en1944(2), en1953(3)} | not-accessible | mandatory |
| mcmCClockDiv OBJECT-TYPE The clock divisor. Values are 1250, 622 or 155 in the appropriate clock frequency scale. | 1.3.6.1.4.1.4253.2.3.9.3.1.19 | INTEGER {dout-1250(1), dout-622(2), dout-155(3)} | not-accessible | mandatory |
| mcmPortCCntrTable OBJECT-TYPE This table represents the information for each MCM port's current counters. | 1.3.6.1.4.1.4253.2.3.9.4 | not-accessible | mandatory | |
| mcmPortCCntrEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.9.4.1 | not-accessible | mandatory | |
| mcmPortCCntrCardLocation OBJECT-TYPE Location of the MCM port. Valid values are: Local in the same chassis, or remote to this chassis | 1.3.6.1.4.1.4253.2.3.9.4.1.1 | CardLocation | not-accessible | mandatory |
| mcmPortCCntrCardShelf OBJECT-TYPE The shelf the card is in. Valid values are: 2..3. | 1.3.6.1.4.1.4253.2.3.9.4.1.2 | CardShelf | not-accessible | mandatory |
| mcmPortCCntrCardSlot OBJECT-TYPE The slot within the shelf the Module is in. | 1.3.6.1.4.1.4253.2.3.9.4.1.3 | CardSlot | not-accessible | mandatory |
| mcmPortCCntrIndex OBJECT-TYPE Port's index. | 1.3.6.1.4.1.4253.2.3.9.4.1.4 | INTEGER | not-accessible | mandatory |
| mcmPortCCntrASs OBJECT-TYPE mcm port's ASs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.3.9.4.1.5 | Counter | not-accessible | mandatory |
| mcmPortCCntrFEs OBJECT-TYPE MCM port's FEs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.3.9.4.1.7 | Counter | not-accessible | mandatory |
| mcmPortCCntrCRCErrs OBJECT-TYPE MCM port's CRC errs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.3.9.4.1.8 | Counter | not-accessible | mandatory |
| mcmPortCCntrSESs OBJECT-TYPE mcm port's SESs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.3.9.4.1.9 | Counter | not-accessible | mandatory |
| mcmPortCCntrSEFSs OBJECT-TYPE MCM port's SEFSs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.3.9.4.1.10 | Counter | not-accessible | mandatory |
| mcmPortCCntrUASs OBJECT-TYPE MCM port's UASs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.3.9.4.1.11 | Counter | not-accessible | mandatory |
| mcmPortCCntrLESs OBJECT-TYPE MCM port's LESs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.3.9.4.1.12 | Counter | not-accessible | mandatory |
| mcmPortCCntrBESs OBJECT-TYPE MCM port's BESs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.3.9.4.1.13 | Counter | not-accessible | mandatory |
| mcmPortCCntrDMs OBJECT-TYPE MCM port's DMSs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.3.9.4.1.14 | Counter | not-accessible | mandatory |
| mcmPortCCntrLCVs OBJECT-TYPE MCM port's LCVs counter less than 15 mins. | 1.3.6.1.4.1.4253.2.3.9.4.1.15 | Counter | not-accessible | mandatory |
| fnCond OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.3.10 | |||
| fnCNumEvents OBJECT-TYPE Total number of all traps (events) generated by all Fans since this mode is started. | 1.3.6.1.4.1.4253.2.3.10.1 | Counter | not-accessible | mandatory |
| fnCPerfTable OBJECT-TYPE This table represents the information for performance data collected for each fan module. | 1.3.6.1.4.1.4253.2.3.10.2 | not-accessible | mandatory | |
| fnCPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.10.2.1 | not-accessible | mandatory | |
| fnCPerfID OBJECT-TYPE The module ID where the fan module is plugged in. | 1.3.6.1.4.1.4253.2.3.10.2.1.1 | INTEGER | not-accessible | mandatory |
| fnCPerfState OBJECT-TYPE The state of the fan module. | 1.3.6.1.4.1.4253.2.3.10.2.1.2 | INTEGER {fnOK(1), fnDegrade(2), fnFailed(3), fnEmpty(4)} | not-accessible | mandatory |
| fnCPerfStatus OBJECT-TYPE The status of the fan module. This status represents the status of the fan module and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.3.10.2.1.3 | CardStatus | not-accessible | mandatory |
| rpsmCond OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.3.12 | |||
| rpsmCNumEvents OBJECT-TYPE Total number of all traps (events) generated by all RPSMs' since this mode is started. | 1.3.6.1.4.1.4253.2.3.12.1 | Counter | not-accessible | mandatory |
| rpsmCPerfTable OBJECT-TYPE This table represents the information for performance data collected for each rpsm card | 1.3.6.1.4.1.4253.2.3.12.2 | not-accessible | mandatory | |
| rpsmCPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.12.2.1 | not-accessible | mandatory | |
| rpsmCPerfLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.3.12.2.1.1 | CardLocation | not-accessible | mandatory |
| rpsmCPerfShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.3.12.2.1.2 | CardShelf | not-accessible | mandatory |
| rpsmCPerfSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.3.12.2.1.3 | CardSlot | not-accessible | mandatory |
| rpsmCPerfState OBJECT-TYPE The state of the rpsm card. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.3.12.2.1.4 | CardState | not-accessible | mandatory |
| rpsmCPerfStatus OBJECT-TYPE The status of the rpsm card. This status represents the status of the rpsm card and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.3.12.2.1.5 | CardStatus | not-accessible | mandatory |
| rpsmCAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this rpsm has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.3.12.2.1.6 | Counter | not-accessible | mandatory |
| rpsmCErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this rpsm has not experienced any alarms. | 1.3.6.1.4.1.4253.2.3.12.2.1.7 | Counter | not-accessible | mandatory |
| rpsmCCounterFlag OBJECT-TYPE Turns special condition software counters On or Off for this card. Default is off. | 1.3.6.1.4.1.4253.2.3.12.3 | FlagType | not-accessible | mandatory |
| rsdmCond OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.3.13 | |||
| rsdmCNumEvents OBJECT-TYPE Total number of all traps (events) generated by all RSDMs' since this mode is started. | 1.3.6.1.4.1.4253.2.3.13.1 | Counter | not-accessible | mandatory |
| rsdmCPerfTable OBJECT-TYPE This table represents the information for performance data collected for each oppm card | 1.3.6.1.4.1.4253.2.3.13.2 | not-accessible | mandatory | |
| rsdmCPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.13.2.1 | not-accessible | mandatory | |
| rsdmCPerfLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.3.13.2.1.1 | CardLocation | not-accessible | mandatory |
| rsdmCPerfShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.3.13.2.1.2 | CardShelf | not-accessible | mandatory |
| rsdmCPerfSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.3.13.2.1.3 | CardSlot | not-accessible | mandatory |
| rsdmCPerfState OBJECT-TYPE The state of the rsdm card. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.3.13.2.1.4 | CardState | not-accessible | mandatory |
| rsdmCPerfStatus OBJECT-TYPE The status of the rsdm card. This status represents the status of the rsdm card and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.3.13.2.1.5 | CardStatus | not-accessible | mandatory |
| rsdmCAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this rsdm has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.3.13.2.1.6 | Counter | not-accessible | mandatory |
| rsdmCErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this rsdm has not experienced any alarms. | 1.3.6.1.4.1.4253.2.3.13.2.1.7 | Counter | not-accessible | mandatory |
| rsdmCCounterFlag OBJECT-TYPE Turns special condition software counters On or Off for this card. Default is off. | 1.3.6.1.4.1.4253.2.3.13.3 | FlagType | not-accessible | mandatory |
| rtdmCond OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.3.14 | |||
| rtdmCNumEvents OBJECT-TYPE Total number of all traps (events) generated by all RTDM's since this mode is started. | 1.3.6.1.4.1.4253.2.3.14.1 | Counter | not-accessible | mandatory |
| rtdmCPerfTable OBJECT-TYPE This table represents the information for performance data collected for each mux/demux card | 1.3.6.1.4.1.4253.2.3.14.2 | not-accessible | mandatory | |
| rtdmCPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.14.2.1 | not-accessible | mandatory | |
| rtdmCPerfLocation OBJECT-TYPE The location of the card. Choices are local or remote. | 1.3.6.1.4.1.4253.2.3.14.2.1.1 | CardLocation | not-accessible | mandatory |
| rtdmCPerfShelf OBJECT-TYPE The shelf the card is in. Valid values are: 1 to 10 | 1.3.6.1.4.1.4253.2.3.14.2.1.2 | CardShelf | not-accessible | mandatory |
| rtdmCPerfSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.3.14.2.1.3 | CardSlot | not-accessible | mandatory |
| rtdmCPerfState OBJECT-TYPE The status of the mux card. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.3.14.2.1.4 | CardState | not-accessible | mandatory |
| rtdmCPerfStatus OBJECT-TYPE The status of the mux card. This status represents the status of the mux card and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.3.14.2.1.5 | CardStatus | not-accessible | mandatory |
| rtdmCAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this Mux has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.3.14.2.1.6 | Counter | not-accessible | mandatory |
| rtdmCErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this mux has not experienced any alarms. | 1.3.6.1.4.1.4253.2.3.14.2.1.7 | Counter | not-accessible | mandatory |
| rtdmCCounterFlag OBJECT-TYPE Turns special condition software counters On or Off for this card. Default is off. | 1.3.6.1.4.1.4253.2.3.14.3 | FlagType | not-accessible | mandatory |
| osamCond OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.3.15 | |||
| osamCNumEvents OBJECT-TYPE Total number of events received for all osam's since this mode was started. | 1.3.6.1.4.1.4253.2.3.15.1 | Counter | not-accessible | mandatory |
| osamCPerfTable OBJECT-TYPE This table represents the information for special conditions performance data collected for each osam module. | 1.3.6.1.4.1.4253.2.3.15.2 | not-accessible | mandatory | |
| osamCPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.15.2.1 | not-accessible | mandatory | |
| osamCPerfLocation OBJECT-TYPE Location of the module. | 1.3.6.1.4.1.4253.2.3.15.2.1.1 | CardLocation | not-accessible | mandatory |
| osamCPerfShelf OBJECT-TYPE The shelf number in which the module is plugged in. | 1.3.6.1.4.1.4253.2.3.15.2.1.2 | CardShelf | not-accessible | mandatory |
| osamCPerfSlot OBJECT-TYPE The slot number in which the module is plugged in. | 1.3.6.1.4.1.4253.2.3.15.2.1.3 | INTEGER (1..16) | not-accessible | mandatory |
| osamCPerfState OBJECT-TYPE The current state of the module. | 1.3.6.1.4.1.4253.2.3.15.2.1.4 | CardState | not-accessible | mandatory |
| osamCPerfStatus OBJECT-TYPE The current alarm status of the channel. | 1.3.6.1.4.1.4253.2.3.15.2.1.5 | CardStatus | not-accessible | mandatory |
| osamCPerfAvailTime OBJECT-TYPE The number of seconds since the start of this mode that this module has been up and running. | 1.3.6.1.4.1.4253.2.3.15.2.1.6 | Counter | not-accessible | mandatory |
| osamCPerfErrFreeSecs OBJECT-TYPE The number of seconds since the start of this mode that this module has been experienced any alarms. | 1.3.6.1.4.1.4253.2.3.15.2.1.7 | Counter | not-accessible | mandatory |
| osamCPerfCounterFlag OBJECT-TYPE Turns osam special condition software counters on and off. Default is off. | 1.3.6.1.4.1.4253.2.3.15.3 | FlagType | not-accessible | mandatory |
| rsmCond OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.3.16 | |||
| rsmCNumEvents OBJECT-TYPE Total number of all traps (events) generated by all RSMs' since this mode is started. | 1.3.6.1.4.1.4253.2.3.16.1 | Counter | not-accessible | mandatory |
| rsmCPerfTable OBJECT-TYPE This table represents the information for performance data collected for each rsm card | 1.3.6.1.4.1.4253.2.3.16.2 | not-accessible | mandatory | |
| rsmCPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.16.2.1 | not-accessible | mandatory | |
| rsmCPerfLocation OBJECT-TYPE The location of the card. | 1.3.6.1.4.1.4253.2.3.16.2.1.1 | CardLocation | not-accessible | mandatory |
| rsmCPerfShelf OBJECT-TYPE The shelf the card is in. | 1.3.6.1.4.1.4253.2.3.16.2.1.2 | CardShelf | not-accessible | mandatory |
| rsmCPerfSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.3.16.2.1.3 | CardSlot | not-accessible | mandatory |
| rsmCPerfState OBJECT-TYPE The state of the rsm card. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.3.16.2.1.4 | CardState | not-accessible | mandatory |
| rsmCPerfStatus OBJECT-TYPE The status of the rsm card. This status represents the status of the rsm card and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.3.16.2.1.5 | CardStatus | not-accessible | mandatory |
| rsmCAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this rsm has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.3.16.2.1.6 | Counter | not-accessible | mandatory |
| rsmCErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this rsm has not experienced any alarms. | 1.3.6.1.4.1.4253.2.3.16.2.1.7 | Counter | not-accessible | mandatory |
| rsmCCounterFlag OBJECT-TYPE Turns special condition software counters On or Off for this card. Default is off. | 1.3.6.1.4.1.4253.2.3.16.3 | FlagType | not-accessible | mandatory |
| upsmCond OBJECT-IDENTITY | 1.3.6.1.4.1.4253.2.3.17 | |||
| upsmCNumEvents OBJECT-TYPE Total number of all traps (events) generated by all UPSMs' since this mode is started. | 1.3.6.1.4.1.4253.2.3.17.1 | Counter | not-accessible | mandatory |
| upsmCPerfTable OBJECT-TYPE This table represents the information for performance data collected for each upsm card | 1.3.6.1.4.1.4253.2.3.17.2 | not-accessible | mandatory | |
| upsmCPerfEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.2.3.17.2.1 | not-accessible | mandatory | |
| upsmCPerfLocation OBJECT-TYPE The location of the card. | 1.3.6.1.4.1.4253.2.3.17.2.1.1 | CardLocation | not-accessible | mandatory |
| upsmCPerfShelf OBJECT-TYPE The shelf the card is in. | 1.3.6.1.4.1.4253.2.3.17.2.1.2 | CardShelf | not-accessible | mandatory |
| upsmCPerfSlot OBJECT-TYPE The slot within the shelf the card is in. | 1.3.6.1.4.1.4253.2.3.17.2.1.3 | CardSlot | not-accessible | mandatory |
| upsmCPerfState OBJECT-TYPE The state of the upsm card. The states are: online, offline, empty, loopback or diag. | 1.3.6.1.4.1.4253.2.3.17.2.1.4 | CardState | not-accessible | mandatory |
| upsmCPerfStatus OBJECT-TYPE The status of the upsm card. This status represents the status of the upsm card and in general is different from the status of the system. | 1.3.6.1.4.1.4253.2.3.17.2.1.5 | CardStatus | not-accessible | mandatory |
| upsmCAvailTime OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this upsm has been up and running. This will generally be the same as 15 minutes in seconds (900). | 1.3.6.1.4.1.4253.2.3.17.2.1.6 | Counter | not-accessible | mandatory |
| upsmCErrFreeSecs OBJECT-TYPE The number of seconds in this time slot (15 minutes) that this upsm has not experienced any alarms. | 1.3.6.1.4.1.4253.2.3.17.2.1.7 | Counter | not-accessible | mandatory |
| upsmCCounterFlag OBJECT-TYPE Turns special condition software counters On or Off for this card. Default is off. | 1.3.6.1.4.1.4253.2.3.17.3 | FlagType | not-accessible | mandatory |
| faults OBJECT-IDENTITY | 1.3.6.1.4.1.4253.3 | |||
| eventLog OBJECT-IDENTITY | 1.3.6.1.4.1.4253.3.1 | |||
| eveTrapThreshold OBJECT-TYPE Threshold before events of the same type are no longer sent. Default can be a number as small as 1. | 1.3.6.1.4.1.4253.3.1.1 | INTEGER | not-accessible | mandatory |
| eveNumEvents OBJECT-TYPE Number of events logged in the table below. This counter is automatically set by the software. | 1.3.6.1.4.1.4253.3.1.2 | EventBuffer | read-only | mandatory |
| eveLogTable OBJECT-TYPE This table represents the information for the event log buffer. There are a maximum of 700 entries in the event log. The events are kept in a circular buffer fashion with eveSeqNum going from 1 to 9999. | 1.3.6.1.4.1.4253.3.1.3 | not-accessible | mandatory | |
| eveLogEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.3.1.3.1 | not-accessible | mandatory | |
| eveDateTime OBJECT-TYPE The date and time of the event logged in the buffer | 1.3.6.1.4.1.4253.3.1.3.1.1 | DateAndTime | read-only | mandatory |
| eveEventId OBJECT-TYPE The event ID assigned to this event. | 1.3.6.1.4.1.4253.3.1.3.1.2 | INTEGER (0..9999) | read-only | mandatory |
| eveSeverity OBJECT-TYPE The severity of this event. Could be critical, major, minor, or normal (informational). | 1.3.6.1.4.1.4253.3.1.3.1.3 | TrapStatus | read-only | mandatory |
| eveSysStatus OBJECT-TYPE The current status of the system. Could be critical, major, minor, or normal (informational). | 1.3.6.1.4.1.4253.3.1.3.1.4 | CardStatus | read-only | mandatory |
| eveSource OBJECT-TYPE A five to seven tuple string composed of the following items: System Name:card type (MPM, OCMITU, OFCM, etc.). location (L for local, R[number] for remote with optional station number). shelf #. slot id[. port #][:link name(optional depending on card type)] [:ring name(optional)] [:path name(optional)]. When an event applies to all slots of the whole chassis, 0 will be displayed for both shelf and slot. Example: SystemInSunnyvale:OCMITU.L.1.6:ITU23 | 1.3.6.1.4.1.4253.3.1.3.1.5 | DisplayString (SIZE(0..152)) | read-only | mandatory |
| eveDescr OBJECT-TYPE A string signifying the cause of the error in natural language (preferrably English) format. | 1.3.6.1.4.1.4253.3.1.3.1.6 | DisplayString (SIZE(0..100)) | read-only | mandatory |
| eveTrap OBJECT-TYPE If set to True, this event was sent as a trap. If set to False, this event was merely logged and not sent as a trap. | 1.3.6.1.4.1.4253.3.1.3.1.7 | Boolean | read-only | mandatory |
| eveSeqNum OBJECT-TYPE The unique sequence number for this event entry in the event log. | 1.3.6.1.4.1.4253.3.1.3.1.8 | INTEGER (0..9999) | read-only | mandatory |
| eveDeleteLog OBJECT-TYPE If the value is reset, the event log table of the active cp is deleted - meaning all the log entries are flushed!! | 1.3.6.1.4.1.4253.3.1.4 | ResetType | read-write | mandatory |
| eveLastEntryDateTime OBJECT-TYPE Date and time stamp of the last event log entry. This provides quick access into the last event log entry. | 1.3.6.1.4.1.4253.3.1.5 | DateAndTime | read-only | mandatory |
| eveHundredthEntryDateTime OBJECT-TYPE Date and time stamp of the most recent 100th event log entry. This provides quick access into retrieving the most recent 100 event log entries. If less than 100 entries exist in the event log, the return value contains all zeroes. | 1.3.6.1.4.1.4253.3.1.6 | DateAndTime | read-only | mandatory |
| eveTwoHundredthEntryDateTime OBJECT-TYPE Date and time stamp of the most recent 200th event log entry. This provides quick access into retrieving the most recent 200 event log entries. If less than 200 entries exist in the event log, the return value contains all zeroes. | 1.3.6.1.4.1.4253.3.1.7 | DateAndTime | read-only | mandatory |
| eveThreeHundredthEntryDateTime OBJECT-TYPE Date and time stamp of the most recent 300th event log entry. This provides quick access into retrieving the most recent 300 event log entries. If less than 300 entries exist in the event log, the return value contains all zeroes. | 1.3.6.1.4.1.4253.3.1.8 | DateAndTime | read-only | mandatory |
| eveFourHundredthEntryDateTime OBJECT-TYPE Date and time stamp of the most recent 400th event log entry. This provides quick access into retrieving the most recent 400 event log entries. If less than 400 entries exist in the event log, the return value contains all zeroes. | 1.3.6.1.4.1.4253.3.1.9 | DateAndTime | read-only | mandatory |
| eveFiveHundredthEntryDateTime OBJECT-TYPE Date and time stamp of the most recent 500th event log entry. This provides quick access into retrieving the most recent 500 event log entries. If less than 500 entries exist in the event log, the return value contains all zeroes. | 1.3.6.1.4.1.4253.3.1.10 | DateAndTime | read-only | mandatory |
| eveSixHundredthEntryDateTime OBJECT-TYPE Date and time stamp of the most recent 600th event log entry. This provides quick access into retrieving the most recent 600 event log entries. If less than 600 entries exist in the event log, the return value contains all zeroes. | 1.3.6.1.4.1.4253.3.1.11 | DateAndTime | read-only | mandatory |
| eveSevenHundredthEntryDateTime OBJECT-TYPE Date and time stamp of the most recent 700th event log entry. This provides quick access into retrieving the most recent 700 event log entries. If less than 700 entries exist in the event log, the return value contains all zeroes. | 1.3.6.1.4.1.4253.3.1.12 | DateAndTime | read-only | mandatory |
| eveEightHundredthEntryDateTime OBJECT-TYPE Date and time stamp of the most recent 800th event log entry. This provides quick access into retrieving the most recent 800 event log entries. If less than 800 entries exist in the event log, the return value contains all zeroes. | 1.3.6.1.4.1.4253.3.1.13 | DateAndTime | not-accessible | mandatory |
| eveNineHundredthEntryDateTime OBJECT-TYPE Date and time stamp of the most recent 900th event log entry. This provides quick access into retrieving the most recent 900 event log entries. If less than 900 entries exist in the event log, the return value contains all zeroes. | 1.3.6.1.4.1.4253.3.1.14 | DateAndTime | not-accessible | mandatory |
| userLog OBJECT-IDENTITY | 1.3.6.1.4.1.4253.3.2 | |||
| usrNumLogs OBJECT-TYPE Number of user events logged in the table below. This counter is automatically set by the software. | 1.3.6.1.4.1.4253.3.2.1 | UserBuffer | not-accessible | mandatory |
| usrLogTable OBJECT-TYPE This table represents the information for user event log buffer | 1.3.6.1.4.1.4253.3.2.2 | not-accessible | mandatory | |
| usrLogEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.3.2.2.1 | not-accessible | mandatory | |
| usrDateTime OBJECT-TYPE The date and time of the event logged in the buffer | 1.3.6.1.4.1.4253.3.2.2.1.1 | DateAndTime | not-accessible | mandatory |
| usrLogonId OBJECT-TYPE The Logon ID of the user causing this event to be logged. | 1.3.6.1.4.1.4253.3.2.2.1.2 | LogonID | not-accessible | mandatory |
| usrTarget OBJECT-TYPE A four tuple string composed of the following items: location (remote or local), type (cp, cc, mux or ps), shelf, and slot id. The tuples are separated by comma. Example: local,cp,b,1. This column identifies which subsystem was affected by the user action. | 1.3.6.1.4.1.4253.3.2.2.1.3 | DisplayString (SIZE(0..30)) | not-accessible | mandatory |
| usrLogDescr OBJECT-TYPE A string signifying the action logged in natural language (preferrably English) format. | 1.3.6.1.4.1.4253.3.2.2.1.4 | DisplayString (SIZE(0..100)) | not-accessible | mandatory |
| usrTrap OBJECT-TYPE If set to True, this user event was sent as a trap. If set to False, this event was merely logged and not sent as a trap. | 1.3.6.1.4.1.4253.3.2.2.1.5 | Boolean | not-accessible | mandatory |
| diagnostics OBJECT-IDENTITY | 1.3.6.1.4.1.4253.3.3 | |||
| diagModeNum OBJECT-TYPE Number of cards in diagnostics mode in the table below. This counter is automatically set by the software. | 1.3.6.1.4.1.4253.3.3.1 | INTEGER (0..128) | read-only | mandatory |
| diagModeTable OBJECT-TYPE This table represents the information for each card in diagnostics mode. | 1.3.6.1.4.1.4253.3.3.2 | not-accessible | mandatory | |
| diagModeEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.3.3.2.1 | not-accessible | mandatory | |
| diagLocation OBJECT-TYPE The location of the card: local or remote | 1.3.6.1.4.1.4253.3.3.2.1.1 | CardLocation | read-only | mandatory |
| diagShelf OBJECT-TYPE The shelf in which the card is located. | 1.3.6.1.4.1.4253.3.3.2.1.2 | CardShelf | read-only | mandatory |
| diagSlot OBJECT-TYPE The card slot in which the card is located. | 1.3.6.1.4.1.4253.3.3.2.1.3 | CardSlot | read-only | mandatory |
| diagSetMode OBJECT-TYPE If on, the card will be in diagnostics mode. If off, the card comes out of diagnostics mode. | 1.3.6.1.4.1.4253.3.3.2.1.4 | INTEGER {other(1), warmboot(2), loopbackDisabled(3), loopbackEnabled(4), selftest(5)} | read-only | mandatory |
| diagTestNum OBJECT-TYPE Number of built-in diagnostics tests in the table below. | 1.3.6.1.4.1.4253.3.3.3 | INTEGER (0..20) | read-only | mandatory |
| diagTestTable OBJECT-TYPE This table represents the information for each built-in diagnostics test. | 1.3.6.1.4.1.4253.3.3.4 | not-accessible | mandatory | |
| diagTestEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.3.3.4.1 | not-accessible | mandatory | |
| diagTestId OBJECT-TYPE The name of the built-in diagnostics test. | 1.3.6.1.4.1.4253.3.3.4.1.1 | INTEGER {lLoopBack(1), rLoopBack(2), lNormal(3), rNormal(4)} | read-write | mandatory |
| diagTLocation OBJECT-TYPE The location of the card to run the test on | 1.3.6.1.4.1.4253.3.3.4.1.2 | CardLocation | read-write | mandatory |
| diagTShelf OBJECT-TYPE The shelf in which the card is located. | 1.3.6.1.4.1.4253.3.3.4.1.3 | CardShelf | read-write | mandatory |
| diagTSlot OBJECT-TYPE The card slot in which the card is located. | 1.3.6.1.4.1.4253.3.3.4.1.4 | CardSlot | read-write | mandatory |
| diagParam1 OBJECT-TYPE The first parameter, if any to pass to the built-in test module. This parameter may be NULL to signify no run-time parameters. If there is a parameter in, any data type, it should be passed as a String equivalent. | 1.3.6.1.4.1.4253.3.3.4.1.5 | DisplayString (SIZE(0..30)) | read-write | mandatory |
| diagParam2 OBJECT-TYPE The second parameter, if any to pass to the built-in test module. This parameter may be NULL to signify no more run-time parameters. If there is a parameter in any data type, it should be passed as a String equivalent. | 1.3.6.1.4.1.4253.3.3.4.1.6 | DisplayString (SIZE(0..30)) | read-write | mandatory |
| diagParam3 OBJECT-TYPE The third parameter, if any to pass to the built-in test module. This parameter may be NULL to signify no more run-time parameters. If there is a parameter in any data type, it should be passed as a String equivalent. | 1.3.6.1.4.1.4253.3.3.4.1.7 | DisplayString (SIZE(0..30)) | read-write | mandatory |
| diagTSetMode OBJECT-TYPE If on, the given test will be run on the given card. The value off has no effect in this case and is ignored. | 1.3.6.1.4.1.4253.3.3.4.1.8 | FlagType | read-write | mandatory |
| diagSelfTest OBJECT-IDENTITY | 1.3.6.1.4.1.4253.3.3.5 | |||
| mcmescSelfTest OBJECT-IDENTITY | 1.3.6.1.4.1.4253.3.3.5.1 | |||
| mcmescSelfTestTable OBJECT-TYPE This table represents the self-test results for mcmesc link port. | 1.3.6.1.4.1.4253.3.3.5.1.1 | not-accessible | mandatory | |
| mcmescSelfTestEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.3.3.5.1.1.1 | not-accessible | mandatory | |
| mcmescSelfTestLocation OBJECT-TYPE The location of the card: local or remote. The self test is applicable to local mcmesc only. | 1.3.6.1.4.1.4253.3.3.5.1.1.1.1 | CardLocation | read-only | mandatory |
| mcmescSelfTestShelf OBJECT-TYPE The shelf in which the card is located. | 1.3.6.1.4.1.4253.3.3.5.1.1.1.2 | CardShelf | read-only | mandatory |
| mcmescSelfTestSlot OBJECT-TYPE The card slot in which the card is located. | 1.3.6.1.4.1.4253.3.3.5.1.1.1.3 | CardSlot | read-only | mandatory |
| mcmescSelfTestStart OBJECT-TYPE Initiate a self-test. A get on this will always return an other. Any outstanding loopbacks will be turned off before starting self-test. | 1.3.6.1.4.1.4253.3.3.5.1.1.1.4 | INTEGER {other(1), yes(2)} | read-write | mandatory |
| mcmescSelfTestResult OBJECT-TYPE Indicate an overall result of the latest self-test. The value inprogress(3) will be given if a self-test is in progress. The table mcmescLinkSelfTestResult and mcmescPortSelfTestResult show the detail result of each individual test item. | 1.3.6.1.4.1.4253.3.3.5.1.1.1.5 | INTEGER {passed(1), failed(2), inprogress(3), notreported(4)} | read-only | mandatory |
| mcmescSelfTestSeqNum OBJECT-TYPE Indicate a sequece number associated with the latest complete self test. The sring of inprogress will be given if a self-test is in progress. The table mcmescLinkSelfTestResult and mcmescPortSelfTestResult show the detail result of each individual test item. | 1.3.6.1.4.1.4253.3.3.5.1.1.1.6 | DisplayString | read-only | mandatory |
| mcmescSelfTestTimeStamp OBJECT-TYPE Indicate the time stamp associated with the latest complete self test. The value inprogress(3) will be given if a self-test is in progress. The table mcmescLinkSelfTestResult and mcmescPortSelfTestResult show the detail result of each individual test item. | 1.3.6.1.4.1.4253.3.3.5.1.1.1.7 | DateAndTime | read-only | mandatory |
| mcmescLinkSelfTestResultTable OBJECT-TYPE This table represents the self-test results for mcmesc link port. | 1.3.6.1.4.1.4253.3.3.5.1.2 | not-accessible | mandatory | |
| mcmescLinkSelfTestResultEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.3.3.5.1.2.1 | not-accessible | mandatory | |
| mcmescLinkSelfTestLocation OBJECT-TYPE The location of the card: local or remote. The self test is applicable to local mcmesc only. | 1.3.6.1.4.1.4253.3.3.5.1.2.1.1 | CardLocation | read-only | mandatory |
| mcmescLinkSelfTestShelf OBJECT-TYPE The shelf in which the card is located. | 1.3.6.1.4.1.4253.3.3.5.1.2.1.2 | CardShelf | read-only | mandatory |
| mcmescLinkSelfTestSlot OBJECT-TYPE The card slot in which the card is located. | 1.3.6.1.4.1.4253.3.3.5.1.2.1.3 | CardSlot | read-only | mandatory |
| mcmescLinkSelfTestTxI2c OBJECT-TYPE Indicate the link port's Tx I2C self-test result. The value inprogress(3) will be given if a self-test is in progress. | 1.3.6.1.4.1.4253.3.3.5.1.2.1.4 | INTEGER {passed(1), failed(2), inprogress(3), notreported(4)} | read-only | mandatory |
| mcmescLinkSelfTestCdrI2c OBJECT-TYPE Indicate the link port's CDR I2C self-test result. The value inprogress(3) will be given if a self-test is in progress. | 1.3.6.1.4.1.4253.3.3.5.1.2.1.5 | INTEGER {passed(1), failed(2), inprogress(3), notreported(4)} | read-only | mandatory |
| mcmescLinkSelfTestDataPath OBJECT-TYPE Indicate the link port's data path self-test result. The value inprogress(3) will be given if a self-test is in progress. | 1.3.6.1.4.1.4253.3.3.5.1.2.1.6 | INTEGER {passed(1), failed(2), inprogress(3), notreported(4)} | read-only | mandatory |
| mcmescPortSelfTestResultTable OBJECT-TYPE This table represents the self-test results for mcmesc CPE port. | 1.3.6.1.4.1.4253.3.3.5.1.3 | not-accessible | mandatory | |
| mcmescPortSelfTestResultEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.3.3.5.1.3.1 | not-accessible | mandatory | |
| mcmescPortSelfTestLocation OBJECT-TYPE The location of the card: local or remote. The self test is applicable to local mcmesc only. | 1.3.6.1.4.1.4253.3.3.5.1.3.1.1 | CardLocation | read-only | mandatory |
| mcmescPortSelfTestShelf OBJECT-TYPE The shelf in which the card is located. | 1.3.6.1.4.1.4253.3.3.5.1.3.1.2 | CardShelf | read-only | mandatory |
| mcmescPortSelfTestSlot OBJECT-TYPE The card slot in which the card is located. | 1.3.6.1.4.1.4253.3.3.5.1.3.1.3 | CardSlot | read-only | mandatory |
| mcmescPortSelfTestPort OBJECT-TYPE The CPE port's index. | 1.3.6.1.4.1.4253.3.3.5.1.3.1.4 | INTEGER | read-only | mandatory |
| mcmescPortSelfTestTxI2c OBJECT-TYPE Indicate the CPE port's Tx I2C self-test result. The value inprogress(3) will be given if a self-test is in progress. | 1.3.6.1.4.1.4253.3.3.5.1.3.1.5 | INTEGER {passed(1), failed(2), inprogress(3), notreported(4)} | read-only | mandatory |
| mcmescPortSelfTestCdrI2c OBJECT-TYPE Indicate the CPE port's CDR I2C self-test result. The value inprogress(3) will be given if a self-test is in progress. | 1.3.6.1.4.1.4253.3.3.5.1.3.1.6 | INTEGER {passed(1), failed(2), inprogress(3), notreported(4)} | read-only | mandatory |
| mcmescPortSelfTestTxDataPath OBJECT-TYPE Indicate the CPE port's Tx data path self-test result. The value inprogress(3) will be given if a self-test is in progress. | 1.3.6.1.4.1.4253.3.3.5.1.3.1.7 | INTEGER {passed(1), failed(2), inprogress(3), notreported(4)} | read-only | mandatory |
| mcmescPortSelfTestRxDataPath OBJECT-TYPE Indicate the CPE port's Rx data path self-test result. The value inprogress(3) will be given if a self-test is in progress. | 1.3.6.1.4.1.4253.3.3.5.1.3.1.8 | INTEGER {passed(1), failed(2), inprogress(3), notreported(4)} | read-only | mandatory |
| alarmLog OBJECT-IDENTITY | 1.3.6.1.4.1.4253.3.4 | |||
| alarmNumEvents OBJECT-TYPE Number of alarms logged in the table below. This counter is automatically set by the software. The max is 300 entries. | 1.3.6.1.4.1.4253.3.4.1 | INTEGER (0..300) | read-only | mandatory |
| alarmLogTable OBJECT-TYPE This table represents the information for the alarm log buffer | 1.3.6.1.4.1.4253.3.4.2 | not-accessible | mandatory | |
| alarmLogEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.3.4.2.1 | not-accessible | mandatory | |
| alarmFirstDateTime OBJECT-TYPE The date and time for the first alarm occurrence. | 1.3.6.1.4.1.4253.3.4.2.1.1 | DateAndTime | read-only | mandatory |
| alarmTag OBJECT-TYPE A unique tag used to identify the alarm entry. | 1.3.6.1.4.1.4253.3.4.2.1.2 | INTEGER (1..999) | read-only | mandatory |
| alarmLastDateTime OBJECT-TYPE The date and time for the most recent alarm occurrence. If this is the first time occurrence, it would be same as alarmFirstDateTime. | 1.3.6.1.4.1.4253.3.4.2.1.3 | DateAndTime | read-only | mandatory |
| alarmEventId OBJECT-TYPE The event ID assigned to this alarm. | 1.3.6.1.4.1.4253.3.4.2.1.4 | INTEGER (0..9999) | read-only | mandatory |
| alarmSeverity OBJECT-TYPE The severity of this alarm. Could be critical, major, or minor. | 1.3.6.1.4.1.4253.3.4.2.1.5 | INTEGER {critical(1), major(2), minor(3)} | read-only | mandatory |
| alarmSource OBJECT-TYPE A five to seven tuple string composed of the following items: System Name:card type (MPM, OCMITU, OFCM, etc.). location (L for local, R[number] for remote with optional station number). shelf #. slot id[. port #][:link name(optional depending on card type)][:ring name (optional)] [:pathname(optional)]. When an event applies to all slots of the whole chassis, 0 will be displayed for both shelf and slot. Example: SystemInSunnyvale:OCMITU.L.1.6:ITU23 | 1.3.6.1.4.1.4253.3.4.2.1.6 | DisplayString (SIZE(0..152)) | read-only | mandatory |
| alarmDescr OBJECT-TYPE A string signifying the cause of the error in natural language (preferrably English) format. | 1.3.6.1.4.1.4253.3.4.2.1.7 | DisplayString (SIZE(0..100)) | read-only | mandatory |
| alarmCnt OBJECT-TYPE Number of times alarm has occurred(from the same source). | 1.3.6.1.4.1.4253.3.4.2.1.8 | INTEGER | read-only | mandatory |
| alarmAck OBJECT-TYPE Acknowledge or unacknowledge the active alarm. Ack will remove its contribution to the external dry contact alarm closure. Default is unacknowledged. | 1.3.6.1.4.1.4253.3.4.2.1.9 | INTEGER {acknowledged(1), unacknowledged(2)} | read-write | mandatory |
| alarmClear OBJECT-TYPE An action to clear the alarm from the alarm log. If alarm persists, another alarm will be sent. A GET operation would always return other(1). | 1.3.6.1.4.1.4253.3.4.2.1.10 | INTEGER {other(1), clear(2)} | read-write | mandatory |
| alarmLastChange OBJECT-TYPE Time ticks in microseconds of when the last change was made to the alarm log. This includes ack/unack, clear, and alarm addition/deletion. | 1.3.6.1.4.1.4253.3.4.3 | INTEGER | read-only | mandatory |
| security OBJECT-IDENTITY | 1.3.6.1.4.1.4253.4 | |||
| userSecMgmt OBJECT-IDENTITY | 1.3.6.1.4.1.4253.4.1 | |||
| usrNumUsers OBJECT-TYPE Number of user Logons in the table below. This counter is automatically set by the software. | 1.3.6.1.4.1.4253.4.1.1 | INTEGER (0..999) | read-only | mandatory |
| usrSecTable OBJECT-TYPE This table represents the information for each user logon entry. | 1.3.6.1.4.1.4253.4.1.2 | not-accessible | mandatory | |
| usrSecEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.4.1.2.1 | not-accessible | mandatory | |
| usrSecLogonId OBJECT-TYPE The unique logon ID assigned to each user. This field should only be written by users that are in the right security role. | 1.3.6.1.4.1.4253.4.1.2.1.1 | LogonID | read-write | mandatory |
| usrSecPasswd OBJECT-TYPE The hashed password for each unique logon ID. To turn the user account off, typically the password is set to some fixed value. Fixed passwords are not accepted as valid passwords. Since this field is one-way hashed, it can be safely read without compromising the security of the system. | 1.3.6.1.4.1.4253.4.1.2.1.2 | HashedPasswd | read-write | mandatory |
| usrSecRole OBJECT-TYPE The role associated with each user logon ID. This is an index into the system role(s) table. | 1.3.6.1.4.1.4253.4.1.2.1.3 | INTEGER | read-write | mandatory |
| usrSecFullName OBJECT-TYPE The full name of the user associated with each unique logon ID. | 1.3.6.1.4.1.4253.4.1.2.1.4 | DisplayString (SIZE(0..45)) | read-write | mandatory |
| usrSecActDateTime OBJECT-TYPE The Time & Date of the user account activation. | 1.3.6.1.4.1.4253.4.1.2.1.5 | DateAndTime | read-only | mandatory |
| usrSecLastDateTime OBJECT-TYPE The Time & Date of the last user logon to the system | 1.3.6.1.4.1.4253.4.1.2.1.6 | DateAndTime | read-only | mandatory |
| usrSecSetLastDateTime OBJECT-TYPE An action to set the Time & Date of the last user logon to the current systemtime. | 1.3.6.1.4.1.4253.4.1.2.1.7 | ResetType | read-write | mandatory |
| systemSecMgmt OBJECT-IDENTITY | 1.3.6.1.4.1.4253.4.2 | |||
| secNumRoles OBJECT-TYPE Number of system security roles in the table below. This counter is automatically set by the software. | 1.3.6.1.4.1.4253.4.2.1 | INTEGER (0..9999) | not-accessible | mandatory |
| secRoleTable OBJECT-TYPE This table represents the information for each system security role entry. | 1.3.6.1.4.1.4253.4.2.2 | not-accessible | mandatory | |
| secRoleEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.4.2.2.1 | not-accessible | mandatory | |
| secRole OBJECT-TYPE Each row in this table defines a unique security role. | 1.3.6.1.4.1.4253.4.2.2.1.1 | EntityName | not-accessible | mandatory |
| secRoleDescr OBJECT-TYPE The full narrated description of each security Role. | 1.3.6.1.4.1.4253.4.2.2.1.2 | DisplayString (SIZE(0..60)) | not-accessible | mandatory |
| secNumGroups OBJECT-TYPE Number of entity groups in the table below. This counter is automatically set by the software. | 1.3.6.1.4.1.4253.4.2.3 | INTEGER (0..9999) | not-accessible | mandatory |
| secGroupTable OBJECT-TYPE This table represents the information for each entity group entry. | 1.3.6.1.4.1.4253.4.2.4 | not-accessible | mandatory | |
| secGroupEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.4.2.4.1 | not-accessible | mandatory | |
| secGroup OBJECT-TYPE Each row in this table defines a grouping of entities or elements from the MIB. | 1.3.6.1.4.1.4253.4.2.4.1.1 | EntityName | not-accessible | mandatory |
| secGroupRole OBJECT-TYPE The containment of this group within a security role. Under the given schema, each Role may have zero or more entity groups. Given an entity group, it may have been contained within one or more roles. | 1.3.6.1.4.1.4253.4.2.4.1.2 | EntityName | not-accessible | mandatory |
| secNumElements OBJECT-TYPE Number of elements or entities in the table below. This counter is automatically set by the software. | 1.3.6.1.4.1.4253.4.2.5 | INTEGER (0..9999) | not-accessible | mandatory |
| secElementTable OBJECT-TYPE This table represents the information for each entity or element in the MIB. | 1.3.6.1.4.1.4253.4.2.6 | not-accessible | mandatory | |
| secElementEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.4.2.6.1 | not-accessible | mandatory | |
| secElement OBJECT-TYPE Each row in this table defines an element or entity from the MIB. | 1.3.6.1.4.1.4253.4.2.6.1.1 | EntityName | not-accessible | mandatory |
| secElementAccess OBJECT-TYPE The original access mode for this element from the MIB. | 1.3.6.1.4.1.4253.4.2.6.1.2 | INTEGER {read(1), write(2), readWrite(3), none(4)} | not-accessible | mandatory |
| secElementOID OBJECT-TYPE The original SNMP OID for this element from the MIB. | 1.3.6.1.4.1.4253.4.2.6.1.3 | DisplayString (SIZE(0..30)) | not-accessible | mandatory |
| secElementType OBJECT-TYPE The original type for this element from the MIB. | 1.3.6.1.4.1.4253.4.2.6.1.4 | INTEGER {element(1), group(2), table(3)} | not-accessible | mandatory |
| secElementParent OBJECT-TYPE The original parent name for this element from the MIB. The parent is either a table or a subgroup. | 1.3.6.1.4.1.4253.4.2.6.1.5 | EntityName | not-accessible | mandatory |
| secNumElmntGrp OBJECT-TYPE Number of element-to-group mappings in the table below. This counter is automatically set by the software. | 1.3.6.1.4.1.4253.4.2.7 | INTEGER (0..9999) | not-accessible | mandatory |
| secElmntGrpTable OBJECT-TYPE This table represents the information for each element-to-group mapping. | 1.3.6.1.4.1.4253.4.2.8 | not-accessible | mandatory | |
| secElmntGrpEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.4.2.8.1 | not-accessible | mandatory | |
| elmntName OBJECT-TYPE Each row in this table defines a mapping of elements to groups. This column is an index into the secElementTable. | 1.3.6.1.4.1.4253.4.2.8.1.1 | EntityName | not-accessible | mandatory |
| grpName OBJECT-TYPE Each row in this table defines a mapping of elements to groups. This column is an index into the secGroupTable. | 1.3.6.1.4.1.4253.4.2.8.1.2 | EntityName | not-accessible | mandatory |
| elmntGrpAccess OBJECT-TYPE The access mode assigned to each element/group entry. Under the given schema, each group may have zero or more MIB elements. Given an element, it may have been contained within one or more groups. The access mode specified here defines what is the granted access mode to the named element contained in this group. Note, the granted access right can never exceed that of the actual MIB access privilege. | 1.3.6.1.4.1.4253.4.2.8.1.3 | INTEGER {read(1), write(2), readWrite(3), none(4)} | not-accessible | mandatory |
| netSecMgmt OBJECT-IDENTITY | 1.3.6.1.4.1.4253.4.3 | |||
| radiusSecMgmt OBJECT-IDENTITY | 1.3.6.1.4.1.4253.4.3.1 | |||
| radiusAuthOrder OBJECT-TYPE The authentication order used when validating a user login id and password. | 1.3.6.1.4.1.4253.4.3.1.1 | INTEGER {local(1), radius(2), localRadius(3), radiusLocal(4)} | read-write | mandatory |
| radiusNasIdentifier OBJECT-TYPE NAS-Identifier for the MPM. | 1.3.6.1.4.1.4253.4.3.1.2 | DisplayString (SIZE(0..32)) | read-write | mandatory |
| radiusDefaultRealm OBJECT-TYPE Default realm used for radius authentication. This realm is not used for local authentication. | 1.3.6.1.4.1.4253.4.3.1.3 | DisplayString (SIZE(0..32)) | read-write | mandatory |
| radiusTimeout OBJECT-TYPE Timeout when sending an authentication request to a radius server. | 1.3.6.1.4.1.4253.4.3.1.4 | INTEGER (1..60) | read-write | mandatory |
| radiusRetries OBJECT-TYPE Number of times to resend requests when a timeout occurs. | 1.3.6.1.4.1.4253.4.3.1.5 | INTEGER (1..10) | read-write | mandatory |
| radiusSecTable OBJECT-TYPE Radius server table. | 1.3.6.1.4.1.4253.4.3.1.6 | not-accessible | mandatory | |
| radiusSecEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.4.3.1.6.1 | not-accessible | mandatory | |
| radiusServerIndex OBJECT-TYPE Index into the radius server table. This index also specifies the server order used for sending authentication requests. | 1.3.6.1.4.1.4253.4.3.1.6.1.1 | INTEGER | read-only | mandatory |
| radiusServerAddress OBJECT-TYPE IP address of the radius server. Setting the address to 0 will delete the server entry. | 1.3.6.1.4.1.4253.4.3.1.6.1.2 | IpAddress | read-write | mandatory |
| radiusServerPort OBJECT-TYPE Radius port used for authentication requests. | 1.3.6.1.4.1.4253.4.3.1.6.1.3 | INTEGER | read-write | mandatory |
| radiusServerSecret OBJECT-TYPE Secret shared with authentication server. | 1.3.6.1.4.1.4253.4.3.1.6.1.4 | DisplayString (SIZE(1..48)) | read-write | mandatory |
| radiusAddServer OBJECT-TYPE Add server to the server table. Servers are added to the first available entry in the server table. To add a server provide server IP address, radius port, and shared secret in the format '<ip address>,<port>, <secret>'. All fields are required. a get on this element will return '0,0,0'. | 1.3.6.1.4.1.4253.4.3.1.7 | DisplayString | read-write | mandatory |
| sshSecMgmt OBJECT-IDENTITY | 1.3.6.1.4.1.4253.4.3.2 | |||
| sshMode OBJECT-TYPE Enables or disables the SSH server. Enabling SSH will disable the built in telnet server. Disabling SSH will enable the telnet server. | 1.3.6.1.4.1.4253.4.3.2.1 | INTEGER {enabled(1), disabled(2)} | read-write | mandatory |
| sshKeySize OBJECT-TYPE The size (in bits) of the DSS key to generate. Key size must be a multiple of 8 and between 512 and 1024 bits. | 1.3.6.1.4.1.4253.4.3.2.2 | INTEGER (512..1024) | read-write | mandatory |
| sshMaxSessions OBJECT-TYPE The maximum number of SSH sessions that can be active at one time. Setting this element will also affect the number of telnet sessions that can be active at a time. | 1.3.6.1.4.1.4253.4.3.2.3 | INTEGER (1..6) | read-write | mandatory |
| sshGenKey OBJECT-TYPE Setting this element to genDssKey(2) will cause a new DSS key to be generated. The process of generating a new key can take some time (several minutes) and may cause significant system slowdown until the process is complete. Reading this element will always return other(1). | 1.3.6.1.4.1.4253.4.3.2.4 | INTEGER {other(1), genDssKey(2)} | read-write | mandatory |
| accounting OBJECT-IDENTITY | 1.3.6.1.4.1.4253.5 | |||
| cpAcct OBJECT-IDENTITY | 1.3.6.1.4.1.4253.5.1 | |||
| acctCPTable OBJECT-TYPE This table represents the information for each system accounting data maintained for each CP. | 1.3.6.1.4.1.4253.5.1.1 | not-accessible | mandatory | |
| acctCPEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.5.1.1.1 | not-accessible | mandatory | |
| acctCPShelf OBJECT-TYPE The shelf in which the given CP card is placed. | 1.3.6.1.4.1.4253.5.1.1.1.1 | CardShelf | read-only | mandatory |
| acctCPSlot OBJECT-TYPE The slot in which the given CP card is placed. | 1.3.6.1.4.1.4253.5.1.1.1.2 | CardSlot | read-only | mandatory |
| acctCPDsgnAct OBJECT-TYPE The total time this CP has been designated Active | 1.3.6.1.4.1.4253.5.1.1.1.3 | Counter | not-accessible | mandatory |
| acctCPDsgnStdby OBJECT-TYPE The total time this CP has been designated Standby | 1.3.6.1.4.1.4253.5.1.1.1.4 | Counter | not-accessible | mandatory |
| acctCPActive OBJECT-TYPE The total time this CP has actually been the primary | 1.3.6.1.4.1.4253.5.1.1.1.5 | Counter | read-only | mandatory |
| acctCPStandby OBJECT-TYPE The total time this CP has actually been the standby | 1.3.6.1.4.1.4253.5.1.1.1.6 | Counter | read-only | mandatory |
| acctCPUpTime OBJECT-TYPE The total time since this CP has been commissioned | 1.3.6.1.4.1.4253.5.1.1.1.7 | Counter | read-only | mandatory |
| acctCPUnAvail OBJECT-TYPE The total time this CP has not been available due to an alarm, diag testing or being put offline | 1.3.6.1.4.1.4253.5.1.1.1.8 | Counter | read-only | mandatory |
| acctCPResetCntrs OBJECT-TYPE If reset, the CP accounting counters will be reset to 0. A get on this will always return other. | 1.3.6.1.4.1.4253.5.1.1.1.9 | ResetType | read-write | mandatory |
| ccAcct OBJECT-IDENTITY | 1.3.6.1.4.1.4253.5.2 | |||
| acctCCTable OBJECT-TYPE This table represents the information for each system accounting data maintained for each CC. | 1.3.6.1.4.1.4253.5.2.1 | not-accessible | mandatory | |
| acctCCEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.5.2.1.1 | not-accessible | mandatory | |
| acctCCLocation OBJECT-TYPE The location of the CC card: local or remote. | 1.3.6.1.4.1.4253.5.2.1.1.1 | CardLocation | read-only | mandatory |
| acctCCShelf OBJECT-TYPE The shelf in which the given CC card is placed. | 1.3.6.1.4.1.4253.5.2.1.1.2 | CardShelf | read-only | mandatory |
| acctCCSlot OBJECT-TYPE The slot in which the given CC card is placed. | 1.3.6.1.4.1.4253.5.2.1.1.3 | CardSlot | read-only | mandatory |
| acctCCUpTime OBJECT-TYPE The total time since this CC has been commissioned | 1.3.6.1.4.1.4253.5.2.1.1.4 | Counter | read-only | mandatory |
| acctCCUnAvail OBJECT-TYPE The total time this CC has not been available due to an alarm, diag testing or being put offline | 1.3.6.1.4.1.4253.5.2.1.1.5 | Counter | read-only | mandatory |
| acctCCResetCntrs OBJECT-TYPE If reset, the CC accounting counters will be reset to 0. A get on this will always return other. | 1.3.6.1.4.1.4253.5.2.1.1.6 | ResetType | read-write | mandatory |
| mcmAcct OBJECT-IDENTITY | 1.3.6.1.4.1.4253.5.3 | |||
| acctmcmTable OBJECT-TYPE This table represents the information for each system accounting data maintained for each MCMT1/MCME1. | 1.3.6.1.4.1.4253.5.3.1 | not-accessible | mandatory | |
| acctmcmEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.5.3.1.1 | not-accessible | mandatory | |
| acctmcmLocation OBJECT-TYPE The location of the MCMT1/MCME1 card: local or remote. | 1.3.6.1.4.1.4253.5.3.1.1.1 | CardLocation | read-only | mandatory |
| acctmcmShelf OBJECT-TYPE The shelf in which the given MCMT1/MCME1 card is placed. | 1.3.6.1.4.1.4253.5.3.1.1.2 | CardShelf | read-only | mandatory |
| acctmcmSlot OBJECT-TYPE The slot in which the given MCMT1/MCME1 card is placed. | 1.3.6.1.4.1.4253.5.3.1.1.3 | CardSlot | read-only | mandatory |
| acctmcmUpTime OBJECT-TYPE The total time since this MCMT1/MCME1 has been commissioned | 1.3.6.1.4.1.4253.5.3.1.1.4 | Counter | read-only | mandatory |
| acctmcmUnAvail OBJECT-TYPE The total time this MCMT1/MCME1 has not been available due to an alarm, diag testing or being put offline | 1.3.6.1.4.1.4253.5.3.1.1.5 | Counter | read-only | mandatory |
| acctmcmResetCntrs OBJECT-TYPE If reset, the MCMT1/MCME1 accounting counters will be reset to 0. A get on this will always return other. | 1.3.6.1.4.1.4253.5.3.1.1.6 | ResetType | read-write | mandatory |
| mcmescAcct OBJECT-IDENTITY | 1.3.6.1.4.1.4253.5.4 | |||
| acctmcmescTable OBJECT-TYPE This table represents the information for each system accounting data maintained for each MCMESC. | 1.3.6.1.4.1.4253.5.4.1 | not-accessible | mandatory | |
| acctmcmescEntry OBJECT-TYPE Specifies the index for each row in the table below | 1.3.6.1.4.1.4253.5.4.1.1 | not-accessible | mandatory | |
| acctmcmescLocation OBJECT-TYPE The location of the MCMESC card: local or remote. | 1.3.6.1.4.1.4253.5.4.1.1.1 | CardLocation | read-only | mandatory |
| acctmcmescShelf OBJECT-TYPE The shelf in which the given MCMESC card is placed. | 1.3.6.1.4.1.4253.5.4.1.1.2 | CardShelf | read-only | mandatory |
| acctmcmescSlot OBJECT-TYPE The slot in which the given MCMESC card is placed. | 1.3.6.1.4.1.4253.5.4.1.1.3 | CardSlot | read-only | mandatory |
| acctmcmescUpTime OBJECT-TYPE The total time since this MCMESC has been commissioned. | 1.3.6.1.4.1.4253.5.4.1.1.4 | Counter | read-only | mandatory |
| acctmcmescUnAvail OBJECT-TYPE The total time this MCMESC has not been available due to an alarm, diag testing or being put offline. | 1.3.6.1.4.1.4253.5.4.1.1.5 | Counter | read-only | mandatory |
| acctmcmescResetCntrs OBJECT-TYPE If reset, the MCMESC accounting counters will be reset to 0. A get on this will always return other. | 1.3.6.1.4.1.4253.5.4.1.1.6 | ResetType | read-only | mandatory |
Notifications
| Name | OID | Status |
|---|---|---|
| luxNGenericTrap NOTIFICATION-TYPE This is a generic trap identifying an event for a given event source. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.1 | |
| luxNVoadmDetectorFailureTrap NOTIFICATION-TYPE This trap is sent when a failure is detected on the VOADM power monitor. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.1001 | |
| luxNVoadmDetectorFailureResolvedTrap NOTIFICATION-TYPE This trap is sent when a failure on the VOADM power monitor has been resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.1002 | |
| luxNVoadmOutofRangeTrap NOTIFICATION-TYPE This trap is sent when the user configured settings for a VOADM would force the power levels to be outside of allowed operating ranges for the current link conditions. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.1003 | |
| luxNVoadmOutofRangeResolvedTrap NOTIFICATION-TYPE This trap is sent when an existing VOADM out of range condition is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.1004 | |
| luxNsignalStrengthHighTrap NOTIFICATION-TYPE This trap is sent when the receieve signal strength is high. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.1005 | |
| luxNsignalStrengthLowTrap NOTIFICATION-TYPE This trap is sent when the receieve signal strength is low. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.1006 | |
| luxNsignalStrengthNormalTrap NOTIFICATION-TYPE This trap is sent when the receieve signal strength is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.1007 | |
| luxNlaserPowerOutOfRangeTrap NOTIFICATION-TYPE This trap is sent upon detection of out of range laser power. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.1008 | |
| luxNlaserPowerNormalTrap NOTIFICATION-TYPE This trap is sent upon detection of normal laser power. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.1009 | |
| luxNberHighThresholdExceeded NOTIFICATION-TYPE This trap is sent upon detecting that MCMESC's BER high threshold is exceeds. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.1010 | |
| luxNberHighThresholdExceededNormal NOTIFICATION-TYPE This trap is sent upon detecting that MCMESC's BER high threshold is not exceeded. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.1011 | |
| luxNberModerateThresholdExceeded NOTIFICATION-TYPE This trap is sent upon detecting that MCMESC's BER moderate threshold is exceeded. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.1012 | |
| luxNberModerateThresholdExceededNormal NOTIFICATION-TYPE This trap is sent upon detecting that MCMESC's BER moderate threshold is not exceeded. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.1013 | |
| luxNSNMPKeepalive NOTIFICATION-TYPE This trap is sent out periodicly by the MPM when SNMP keep alive functionality is enabled. | 1.3.6.1.4.1.4253.0.2000 | |
| luxNSNMPKeepalivesEnabled NOTIFICATION-TYPE This trap is sent upon SNMP keep alive functionality being enabled | 1.3.6.1.4.1.4253.0.2001 | |
| luxNSNMPKeepalivesDisabled NOTIFICATION-TYPE This trap is sent upon SNMP keep alive functionality being disabled | 1.3.6.1.4.1.4253.0.2002 | |
| luxNSNMPKeepaliveIntervalChanged NOTIFICATION-TYPE This trap is sent when the SNMP keep alive interval is modified | 1.3.6.1.4.1.4253.0.2003 | |
| luxNTelnetClientEnabled NOTIFICATION-TYPE Telnet client has been enabled for active telnet sessions | 1.3.6.1.4.1.4253.0.2004 | |
| luxNTelnetClientDisabled NOTIFICATION-TYPE Telnet client has been disabled for active telnet sessions | 1.3.6.1.4.1.4253.0.2005 | |
| luxNsnmpAuthenticationFailureTrap NOTIFICATION-TYPE This trap is sent upon receipt of invalid community strings. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2017 | |
| luxNcoldStartTrap NOTIFICATION-TYPE This trap is sent when the device has reinitialized itself. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2018 | |
| luxNwarmStartTrap NOTIFICATION-TYPE This trap is sent when the device has undergone a warm boot. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2019 | |
| luxNlossOfLightResolvedTrap NOTIFICATION-TYPE This trap is sent when a loss of light condition has been resolved. For OCM/MCMT1/MCME1, it indicates that the link between two optically connected channel cards is up. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2021 | |
| luxNlossOfLightDetectedTrap NOTIFICATION-TYPE This trap is sent when a loss of light condition has been detected. For OCM/MCMT1/MCME1, it indicates that the link between two optically connected channel cards is down. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2022 | |
| luxNntpEnableTrap NOTIFICATION-TYPE This trap is sent when NTP is enabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2023 | |
| luxNntpDisableTrap NOTIFICATION-TYPE This trap is sent when NTP is disabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2024 | |
| luxNntpTimeServerChangedTrap NOTIFICATION-TYPE This trap is sent when the NTP time server is changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2025 | |
| luxNntpUpdateIntervalChangedTrap NOTIFICATION-TYPE This trap is sent when the NTP update interval is changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2026 | |
| luxNtimeZoneChangedTrap NOTIFICATION-TYPE This trap is sent when the system time zone is changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2027 | |
| luxNspiConnectionUpTrap NOTIFICATION-TYPE Obsolete. This trap is sent when SPI communications has been established with a card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2030 | |
| luxNcardLostTrap NOTIFICATION-TYPE This trap is sent when SPI communications has been lost with a card specified in the source field. The reason is either that the card has been physically removed or there exist a failure condition. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2031 | |
| luxNConfigChangeTrap NOTIFICATION-TYPE This trap is sent when a configuration change has ocurred for a card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2034 | |
| luxNstatsPollFailedTrap NOTIFICATION-TYPE This trap is sent when statistics data can no longer be gathered from a card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2035 | |
| luxNCardFoundTrap NOTIFICATION-TYPE This trap is sent when a card has been discovered in the chassis. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2040 | |
| luxNlocalLoopbackEnabledTrap NOTIFICATION-TYPE This trap is sent when the local loopback mode has been enabled for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2041 | |
| luxNremoteLoopbackEnabledTrap NOTIFICATION-TYPE This trap is sent when the remote loopback mode has been enabled for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2042 | |
| luxNlocalLoopbackDisabledTrap NOTIFICATION-TYPE This trap is sent when the local loopback mode has been disabled for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2043 | |
| luxNremoteLoopbackDisabledTrap NOTIFICATION-TYPE This trap is sent when the remote loopback mode has been disabled for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2044 | |
| luxNftpSessionInitiatedTrap NOTIFICATION-TYPE This trap is sent when a ftp session has been initiated from the CLI. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2047 | |
| luxNuserResetStatusTrap NOTIFICATION-TYPE Obsolete. This trap is sent when the status information for a card specified in the source field has been modified via the snmp agent. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2050 | |
| luxNprotectionSwitchTrap NOTIFICATION-TYPE This trap is sent when a protection switch has occurred either automatically or manually. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2051 | |
| luxNipAddressErrorTrap NOTIFICATION-TYPE Obsolete. This trap is sent when an error has occurred while configuring the IP address. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2052 | |
| luxNipNetmaskErrorTrap NOTIFICATION-TYPE Obsolete. This trap is sent when an error has occurred while configuring the Netmask. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2053 | |
| luxNdefaultGatewayErrorTrap NOTIFICATION-TYPE Obsolete. This trap is sent when an error has occurred while configuring the default gateway. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2054 | |
| luxNlossOfSignalTrap NOTIFICATION-TYPE This trap is sent when a loss of signal is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2055 | |
| luxNlossOfSignalNormalTrap NOTIFICATION-TYPE This trap is sent when a loss of signal problem on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2056 | |
| luxNlossOfFrameTrap NOTIFICATION-TYPE This trap is sent when a loss of frame error condition is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2057 | |
| luxNlossOfFrameNormalTrap NOTIFICATION-TYPE This trap is sent when a loss of frame error condition on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2058 | |
| luxNrecvAISTrap NOTIFICATION-TYPE This trap is sent when a receive AIS (Alarm Indication Signal) is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2059 | |
| luxNrecvAISNormalTrap NOTIFICATION-TYPE This trap is sent when a receive AIS (Alarm Indication Signal) problem on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2060 | |
| luxNrecvYellowAlarmTrap NOTIFICATION-TYPE This trap is sent when a receive receive yellow alarm is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2061 | |
| luxNrecvYellowAlarmNormalTrap NOTIFICATION-TYPE This trap is sent when a receive receive yellow alarm problem on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2062 | |
| luxNlineCodeViolationTrap NOTIFICATION-TYPE This trap is sent when a line code violation error condition is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2063 | |
| luxNlineCodeViolationNormalTrap NOTIFICATION-TYPE This trap is sent when a line code violation error condition on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2064 | |
| luxNframingAlarmTrap NOTIFICATION-TYPE This trap is sent when a framing alarm is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2065 | |
| luxNframingAlarmNormalTrap NOTIFICATION-TYPE This trap is sent when a framing alarm problem on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2066 | |
| luxNlossOfTimingTrap NOTIFICATION-TYPE This trap is sent when a loss of timing condition is detected on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2067 | |
| luxNlossOfTimingNormalTrap NOTIFICATION-TYPE This trap is sent when a loss of timing problem on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2068 | |
| luxNselfTestFailTrap NOTIFICATION-TYPE This trap is sent when a self-test failure is detected on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2073 | |
| luxNselfTestPassTrap NOTIFICATION-TYPE This trap is sent when a successful self-test is detected on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2074 | |
| luxNIbmDownTrap NOTIFICATION-TYPE This trap is sent when a problem is detected on a inband management link. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2075 | |
| luxNIbmNormalTrap NOTIFICATION-TYPE This trap is sent when a problem is resolved on a inband management link. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2076 | |
| luxNnearendCardLoopbackEnabledTrap NOTIFICATION-TYPE This trap is sent to indicate that a near-end card loopback has been enabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2077 | |
| luxNnearendCardLoopbackDisabledTrap NOTIFICATION-TYPE This trap is sent to indicate that a near-end card loopback has been disabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2078 | |
| luxNnetworkPortLoopbackEnabledTrap NOTIFICATION-TYPE This trap is sent to indicate that a network port loopback has been enabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2079 | |
| luxNnetworkPortLoopbackDisabledTrap NOTIFICATION-TYPE This trap is sent to indicate that a network port loopback has been disabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2080 | |
| luxNnetworkCardLoopbackEnabledTrap NOTIFICATION-TYPE This trap is sent to indicate that a network card loopback has been enabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2081 | |
| luxNnetworkCardLoopbackDisabledTrap NOTIFICATION-TYPE This trap is sent to indicate that a network card loopback has been disabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2082 | |
| luxNnearendPortLoopbackEnabledTrap NOTIFICATION-TYPE This trap is sent to indicate that a nearend port loopback has been enabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2083 | |
| luxNnearendPortLoopbackDisabledTrap NOTIFICATION-TYPE This trap is sent to indicate that a nearend port loopback has been disabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2084 | |
| luxNpowerSupplyNotPresentTrap NOTIFICATION-TYPE This trap is sent to indicate that the power supply specified in the source field is not present. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2085 | |
| luxNpowerSupplyOKTrap NOTIFICATION-TYPE This trap is sent to indicate that the power supply specified in the source field is performing properly. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2086 | |
| luxNpowerSupplyDegradedTrap NOTIFICATION-TYPE This trap is sent to indicate that the performance of the power supply specified in the source field has degraded. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2087 | |
| luxNpowerSupplyFailureTrap NOTIFICATION-TYPE This trap is sent to indicate that the power supply specified in the source field has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2088 | |
| luxNfanOKTrap NOTIFICATION-TYPE This trap is sent to indicate that the fan specified in the source field is performing properly. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2089 | |
| luxNfanFailureTrap NOTIFICATION-TYPE This trap is sent to indicate that the fan specified in the source field has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2090 | |
| luxNcsimDataUnavailableTrap NOTIFICATION-TYPE This trap is sent to indicate that the ColorSIM module as specified in the source field is in a Data Unavailable state. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2091 | |
| luxNcsimDataAvailableTrap NOTIFICATION-TYPE This trap is sent to indicate that the ColorSIM module as specified in the source field is in a Data Available state. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2092 | |
| luxNcsimModuleFailureTrap NOTIFICATION-TYPE This trap is sent to indicate that the ColorSIM module as specified in the source field has failed to operate properly. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2093 | |
| luxNethernetLossOfCarrierTrap NOTIFICATION-TYPE This trap is sent to indicate that loss of carrier has been detected on the CPE's ethernet port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2094 | |
| luxNethernetCarrierDetectedTrap NOTIFICATION-TYPE This trap is sent to indicate that the carrier has been detected on the CPE's ethernet port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2095 | |
| luxNtimingPriorityChangedTrap NOTIFICATION-TYPE This trap is sent to indicate that the timing priority for a card has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2096 | |
| luxNopenFiberCPEAlarmTrap NOTIFICATION-TYPE This trap is sent when an open fiber condition on the CPE has been detected from a card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2097 | |
| luxNopenFiberCPEAlarmResolvedTrap NOTIFICATION-TYPE This trap is sent when an open fiber condition on the CPE has been resolved from a card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2098 | |
| luxNstandbyMPMDetectedTrap NOTIFICATION-TYPE This trap is sent when the standby MPM card has been detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2099 | |
| luxNstandbyMPMLostTrap NOTIFICATION-TYPE This trap is sent when the standby MPM card has been lost. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2100 | |
| luxNprotectionLinkFailureTrap NOTIFICATION-TYPE This trap is sent when the protection link has become unaviable due to either low receive power level or an open fiber condition. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2101 | |
| luxNprotectionLinkFailureResolvedTrap NOTIFICATION-TYPE This trap is sent when the protection link has become available as a result of a corrective action to resolve a previous failure condition. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2102 | |
| luxNtopologyDatabaseChangedTrap NOTIFICATION-TYPE This trap is sent whenever a link has either been added or deleted from the topology database. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2103 | |
| luxNredundantDatabaseCopyComplete NOTIFICATION-TYPE This trap is sent upon completion of a forced redundant database copy. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2104 | |
| luxNredundantDatabaseCopyFailed NOTIFICATION-TYPE This trap is sent when a failure occurs during a forced redundant database copy. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2105 | |
| luxNimageExportInProgressTrap NOTIFICATION-TYPE This trap is sent when an module image is being exported from the MPM through ftp. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2106 | |
| luxNimageExportSuccessTrap NOTIFICATION-TYPE This trap is sent when a module image exported from the MPM through ftp has been completed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2107 | |
| luxNimageExportFailedTrap NOTIFICATION-TYPE This trap is sent when a module image exported from the MPM through ftp has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2108 | |
| luxNunknownCardTypeDetectedTrap NOTIFICATION-TYPE This trap is sent when a module with an unknown card type is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2109 | |
| luxNosamBiasCurrentOverLimitTrap NOTIFICATION-TYPE This trap is sent when the osam's bias current exceeds 90% of allowed maximum. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2110 | |
| luxNosamBiasCurrentNormal NOTIFICATION-TYPE This trap is sent when the osam's bias current is within normal range. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2111 | |
| luxNosamTecCurrentOverLimit NOTIFICATION-TYPE This trap is sent when the osam's TEC current is above the specified limit. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2112 | |
| luxNosamTecCurrentNormal NOTIFICATION-TYPE This trap is sent when the osam's TEC current is within normal range. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2113 | |
| luxNosamLaserTemperatureDrift NOTIFICATION-TYPE This trap is sent when the osam's laser temperature drifts by more than +/- 2 degree Celsius. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2114 | |
| luxNosamLaserTemperatureStable NOTIFICATION-TYPE This trap is sent when the osam's laser temperature no longer drifts. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2115 | |
| luxNosamMaxInputPowerReached NOTIFICATION-TYPE This trap is sent when the osam's input power is greater than or equal to 9 dBm. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2116 | |
| luxNosamInputPowerBackDownNormal NOTIFICATION-TYPE This trap is sent when the osam's input power has fallen within normal range. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2117 | |
| luxNosamMaxOutputPowerReached NOTIFICATION-TYPE This trap is sent when the osam's output power is greater than or equal to 13 dBm. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2118 | |
| luxNosamOutputPowerNormal NOTIFICATION-TYPE This trap is sent when the osam's output power is within normal range. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2119 | |
| luxNosamOpticalGainDeltaExceeded NOTIFICATION-TYPE This trap is sent when the osam's gain delta is greater than or equal to 4 dB. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2120 | |
| luxNosamOpticalGainDeltaNormal NOTIFICATION-TYPE This trap is sent when the osam's gain delta is less than 4 dB. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2121 | |
| luxNosamMinInputPowerBelowLimit NOTIFICATION-TYPE This trap is sent when the osam's input power is less than or equal to -30 dBm. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2122 | |
| luxNosamInputPowerBackUpNormal NOTIFICATION-TYPE This trap is sent when the osam's input power has risen within normal range. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2123 | |
| luxNosamSingleAprSensorFailed NOTIFICATION-TYPE This trap is sent when the osam's APR sensor is not functioning. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2124 | |
| luxNosamSingleAprSensorNormal NOTIFICATION-TYPE This trap is sent when the osam's APR sensor has become functional. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2125 | |
| luxNosamDualAprSensorFailed NOTIFICATION-TYPE This trap is sent when both of the osam's APR sensors are not functioning. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2126 | |
| luxNosamDualAprSensorNormal NOTIFICATION-TYPE This trap is sent when both of the osam's APR sensors has become functional. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2127 | |
| luxNosamFiberDisconnected NOTIFICATION-TYPE This trap is sent when a fiber disconnect condition has been detected on an osam module. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2128 | |
| luxNosamFiberConnected NOTIFICATION-TYPE This trap is sent when a fiber connect condition has been detected after a fiber disconnect on an osam module. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2129 | |
| luxNosamControlChanged NOTIFICATION-TYPE This trap is sent when either the current control or gain control has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2130 | |
| luxNosamLaserModuleOn NOTIFICATION-TYPE This trap is sent when the laser module has been turned on by the osam firmware. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2131 | |
| luxNosamLaserModuleOff NOTIFICATION-TYPE This trap is sent when the laser module has been turned off by the osam firmware. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2132 | |
| luxNipAuthenticationFailure NOTIFICATION-TYPE Not yet supported. This trap is sent when access from an invalid IP address based on the ACL has been detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2133 | |
| luxNftpCompletedTrap NOTIFICATION-TYPE This trap is sent when the ftp session has been disconnected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2134 | |
| luxNftpHostFailedTrap NOTIFICATION-TYPE This trap is sent when the MPM is unable to connect to the ftp host. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2135 | |
| luxNimageUpdateInProgressTrap NOTIFICATION-TYPE This trap is sent when an module image is being downloaded to MPM through ftp. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2136 | |
| luxNimageUpdateSuccessTrap NOTIFICATION-TYPE This trap is sent when a module image download to MPM through ftp has been completed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2137 | |
| luxNimageUpdateFailedTrap NOTIFICATION-TYPE This trap is sent when a module image download to MPM through ftp has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2138 | |
| luxNmoduleUpdateInProgressTrap NOTIFICATION-TYPE This trap is sent when a module image is being transferred from the MPM to the module. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2139 | |
| luxNmoduleUpdateSuccessTrap NOTIFICATION-TYPE This trap is sent when a module image transfer from the MPM to the module has been completed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2140 | |
| luxNmoduleUpdateFailedTrap NOTIFICATION-TYPE This trap is sent when a module image transfer from the MPM to the module has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2141 | |
| luxNethernetLinkFailure NOTIFICATION-TYPE This trap is sent upon detection of the ethernet link failure on the MPM. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2142 | |
| luxNethernetLinkFailureResolved NOTIFICATION-TYPE This trap is sent upon resolution of the ethernet link failure on the MPM. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2143 | |
| luxNfanNotPresentTrap NOTIFICATION-TYPE This trap is sent to indicate that the fan specified in the source field is not present in the system. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2144 | |
| luxNcardMismatchTrap NOTIFICATION-TYPE This trap is sent when a card mismatch is found in a given slot. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2145 | |
| luxNpwrFeedLowVoltageTrap NOTIFICATION-TYPE This trap is sent when the DC voltage level on the power feed reaches very close to the shutdown voltage. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2146 | |
| luxNpwrFeedLowVoltageRecoveryTrap NOTIFICATION-TYPE This trap is sent when the DC voltage level on the power feed recovers from the low voltage level condition . The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2147 | |
| luxNpwrFeedOKTrap NOTIFICATION-TYPE This trap is sent when the DC voltage level on the power feed is within the operating window of the chassis . The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2148 | |
| luxNpwrFeedFailureTrap NOTIFICATION-TYPE This trap is sent when the DC voltage level on the power feed is either too low or too high to operate the chassis The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2149 | |
| luxNpwrFeedBrkOpenTrap NOTIFICATION-TYPE This trap is sent when a user manually flips open the breaker relay switch attached to that feed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2150 | |
| luxNextCritAlmInpTrap NOTIFICATION-TYPE This trap is sent when an alarm gets generated at an external alarm input that is configured for critical severity. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2151 | |
| luxNextMajAlmInpTrap NOTIFICATION-TYPE This trap is sent when an alarm gets generated at an external alarm input that is configured for majority severity. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2152 | |
| luxNextMinorAlmInpTrap NOTIFICATION-TYPE This trap is sent when an alarm gets generated at an external alarm input that is configured for minor severity. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2153 | |
| luxNextClearAlmInpTrap NOTIFICATION-TYPE This trap is sent when an alarm gets cleared at an external alarm input. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2154 | |
| luxNpwrFeedOverVoltageTrap NOTIFICATION-TYPE This trap is sent when the DC voltage level on the power feed reaches very close to the shutdown voltage on the higher side. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2155 | |
| luxNpwrFeedOverVoltageRecoveryTrap NOTIFICATION-TYPE This trap is sent when the DC voltage level on the power feed recovers from the over voltage level condition . The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2156 | |
| luxNstandbySWMismatchTrap NOTIFICATION-TYPE This trap is sent when there is a mismatch between the software version of standby and active MPM. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2157 | |
| luxNstandbyDBNotSupportedTrap NOTIFICATION-TYPE This trap is sent when the standby MPM do not support Active MPM's database. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2158 | |
| luxNactiveStandbySWAlignedTrap NOTIFICATION-TYPE This trap is sent when the software version between standby and active MPM is aligned. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2159 | |
| luxNactiveStandbyDBAlignedTrap NOTIFICATION-TYPE This trap is sent when the database version between standby and active MPM is aligned. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2160 | |
| luxNmcmescTestSequenceOnTrap NOTIFICATION-TYPE This trap is sent when the test-sequence is set to ON on an MCMESC card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2161 | |
| luxNmcmescTestSequenceOffTrap NOTIFICATION-TYPE This trap is sent when the test-sequence is set to OFF on an MCMESC card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2162 | |
| luxNselfTestStartedTrap NOTIFICATION-TYPE This trap is sent when self-test has started for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2163 | |
| luxNselfTestEndedTrap NOTIFICATION-TYPE This trap is sent when self-test has ended for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2164 | |
| luxNvoadmMuxSetPointOutOfRange NOTIFICATION-TYPE This trap is sent when a VOADM module has detected that the recently configured mux set point value would bring down the fibre if applied. The set point value is rejected and the MPM and module returns to the previously configured mux set point. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2165 | |
| luxNvoadmDemuxForceConfig NOTIFICATION-TYPE This trap is sent when a VOADM module forces its Demux configuration into fixed power mode. Forcing the Demux mode to fixed power mode can only occur when the Demux ports are configured for fixed attentuation mode and network conditions change sufficently that the current configuration may cause damage to the laser. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2166 | |
| luxNSfpNotPresent NOTIFICATION-TYPE This trap is sent when a missing SFP is detect. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2167 | |
| luxNSfpPresent NOTIFICATION-TYPE This trap is sent when a SFP has been inserted into the module .The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2168 | |
| luxNSfpFailure NOTIFICATION-TYPE This trap is sent when a SFP failure is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2169 | |
| luxNSfpFailureResolved NOTIFICATION-TYPE This trap is sent when a SFP failure is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2170 | |
| luxNSfpNotAuthorized NOTIFICATION-TYPE This trap is sent when an unauthorized SFP is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2171 | |
| luxNSfpAuthorized NOTIFICATION-TYPE This trap is sent when an unauthorized SFP is replaced with an authorized SFP. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2172 | |
| luxNSfpRateMismatch NOTIFICATION-TYPE This trap is sent when a SFP does not supported the user configured line rate. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2173 | |
| luxNSfpRateMismatchResolved NOTIFICATION-TYPE This trap is sent when a SFP that does not support the user configured line rate is replaced with an SFP that does. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2174 | |
| luxNLinkRxSignalDegraded NOTIFICATION-TYPE This trap is sent when the packet error rate increases over 10e-4. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2175 | |
| luxNLinkRxSignalDegradedResolved NOTIFICATION-TYPE This trap is sent when the packet error rate falls below 10e-4. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2176 | |
| luxNLinkTxFault NOTIFICATION-TYPE This trap is sent when a Tx fault is detect on the link port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2177 | |
| luxNLinkTxFaultResolved NOTIFICATION-TYPE This trap is sent when a Tx fault is resolved on the link port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2178 | |
| luxNPortTxFault NOTIFICATION-TYPE This trap is sent when a Tx fault is detect on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2179 | |
| luxNPortTxFaultResolved NOTIFICATION-TYPE This trap is sent when a Tx fault is resolved on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2180 | |
| luxNXfpNotPresent NOTIFICATION-TYPE This trap is sent when a missing XFP is detect. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2181 | |
| luxNXfpPresent NOTIFICATION-TYPE This trap is sent when a XFP has been inserted into the module .The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2182 | |
| luxNXfpFailure NOTIFICATION-TYPE This trap is sent when a XFP failure is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2183 | |
| luxNXfpFailureResolved NOTIFICATION-TYPE This trap is sent when a XFP failure is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2184 | |
| luxNXfpNotAuthorized NOTIFICATION-TYPE This trap is sent when an unauthorized XFP is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2185 | |
| luxNXfpAuthorized NOTIFICATION-TYPE This trap is sent when an unauthorized XFP is replaced with an authorized XFP. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2186 | |
| luxNXfpRateMismatch NOTIFICATION-TYPE This trap is sent when a XFP does not supported the user configured line rate. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2187 | |
| luxNXfpRateMismatchResolved NOTIFICATION-TYPE This trap is sent when a XFP that does not support the user configured line rate is replaced with a XFP that does. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2188 | |
| luxNCpeXfpNotPresent NOTIFICATION-TYPE This trap is sent when a missing XFP is detect for a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2189 | |
| luxNCpeXfpPresent NOTIFICATION-TYPE This trap is sent when a XFP has been inserted into the module CPE port.The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2190 | |
| luxNCpeXfpFailure NOTIFICATION-TYPE This trap is sent when a CPE XFP failure is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2191 | |
| luxNCpeXfpFailureResolved NOTIFICATION-TYPE This trap is sent when a CPE XFP failure is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2192 | |
| luxNCpeXfpNotAuthorized NOTIFICATION-TYPE This trap is sent when an unauthorized XFP is detected in a CPE prot. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2193 | |
| luxNCpeXfpAuthorized NOTIFICATION-TYPE This trap is sent when an unauthorized XFP is replaced with an authorized XFP in a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2194 | |
| luxNCpeXfpRateMismatch NOTIFICATION-TYPE This trap is sent when a CPE XFP does not supported the user configured line rate. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2195 | |
| luxNCpeXfpRateMismatchResolved NOTIFICATION-TYPE This trap is sent when a CPE XFP that does not support the user configured line rate is replaced with an XFP that does. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2196 | |
| luxNOutOfFrame NOTIFICATION-TYPE This trap is sent when an out of frame error is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2197 | |
| luxNOutOfFrameResolved NOTIFICATION-TYPE This trap is sent when an out of frame error is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2198 | |
| luxNCpeLossOfFrame NOTIFICATION-TYPE This trap is sent when a loss of frame error is detected on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2199 | |
| luxNCpeLossOfFrameResolved NOTIFICATION-TYPE This trap is sent when a loss of frame error is resolved on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2200 | |
| luxNCpeOutOfFrame NOTIFICATION-TYPE This trap is sent when an out of frame error is detected on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2201 | |
| luxNCpeOutOfFrameResolved NOTIFICATION-TYPE This trap is sent when an out of frame error is resolved on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2202 | |
| luxNCdrFailure NOTIFICATION-TYPE This trap is sent when a CDR failure is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2203 | |
| luxNCdrFailureResolved NOTIFICATION-TYPE This trap is sent when a CDR failure is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2204 | |
| luxNBitError10Em3 NOTIFICATION-TYPE This trap is sent when the modules bit error rate exceeds 10E-3. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2205 | |
| luxNBitError10Em3Resolved NOTIFICATION-TYPE This trap is sent when the modules bit error rate falls below 10E-3. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2206 | |
| luxNBitError10Em4 NOTIFICATION-TYPE This trap is sent when the modules bit error rate exceeds 10E-4. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2207 | |
| luxNBitError10Em4Resolved NOTIFICATION-TYPE This trap is sent when the modules bit error rate falls below 10E-4. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2208 | |
| luxNBitError10Em6 NOTIFICATION-TYPE This trap is sent when the modules bit error rate exceeds 10E-6. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2209 | |
| luxNBitError10Em6Resolved NOTIFICATION-TYPE This trap is sent when the modules bit error rate falls below 10E-6. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2210 | |
| luxNBitError10Em7 NOTIFICATION-TYPE This trap is sent when the modules bit error rate exceeds 10E-7. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2211 | |
| luxNBitError10Em7Resolved NOTIFICATION-TYPE This trap is sent when the modules bit error rate falls below 10E-7. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2212 | |
| luxNAisReceived NOTIFICATION-TYPE This trap is sent when AIS-L is received on the port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2213 | |
| luxNAisReceivedResolved NOTIFICATION-TYPE This trap is sent when AIS-L is no longer received on the port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2214 | |
| luxNAisTransmitted NOTIFICATION-TYPE This trap is sent when starts transmitting on the port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2215 | |
| luxNAisTransmittedResolved NOTIFICATION-TYPE This trap is sent when is no longer transmitting on the port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2216 | |
| luxNcaseTemperatureHiTrap NOTIFICATION-TYPE This trap is sent when case temperature is HI. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2225 | |
| luxNcaseTemperatureNormalTrap NOTIFICATION-TYPE This trap is sent when case temperature is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2226 | |
| luxNcaseTemperatureLoTrap NOTIFICATION-TYPE This trap is sent when case temperature is LO. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2227 | |
| luxNcaseTemperatureLoNormalTrap NOTIFICATION-TYPE This trap is sent when case temperature is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2228 | |
| luxNpumpTemperatureHiTrap NOTIFICATION-TYPE This trap is sent when pump temperature is HI. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2229 | |
| luxNpumpTemperatureNormalTrap NOTIFICATION-TYPE This trap is sent when pump temperature is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2230 | |
| luxNcoilTemperatureHiTrap NOTIFICATION-TYPE This trap is sent when coil temperature is HI. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2231 | |
| luxNcoilTemperatureNormalTrap NOTIFICATION-TYPE This trap is sent when coil temperature is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2232 | |
| luxNlossOutputPowerTrap NOTIFICATION-TYPE This trap is sent when loss of output power (or gain) is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2233 | |
| luxNlossOutputPowerNormalTrap NOTIFICATION-TYPE This trap is sent when loss of output power (or gain) is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2234 | |
| luxNreflectedOutputPowerHiTrap NOTIFICATION-TYPE This trap is sent when excessive reflected output power is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2235 | |
| luxNreflectedOutputPowerNormalTrap NOTIFICATION-TYPE This trap is sent when reflected output power is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.2236 | |
| luxNlineRateNotSuppoted NOTIFICATION-TYPE This trap is sent to indicate that the module hardware does not support the configured line rate. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3001 | |
| luxNmpmBootImageChangedTrap NOTIFICATION-TYPE This trap is sent to indicate that the executable image for the MPM has been changed. Upon reset of the MPM card, this new bootfile will be used. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3002 | |
| luxNdateTimeSetTrap NOTIFICATION-TYPE This trap is sent to indicate that the date and time of the system has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3003 | |
| luxNuserAddedTrap NOTIFICATION-TYPE This trap is sent to indicate that a new user has been added to the system. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3004 | |
| luxNuserDeletedTrap NOTIFICATION-TYPE This trap is sent to indicate that a user has been deleted from the system. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3005 | |
| luxNuserPasswordChangeTrap NOTIFICATION-TYPE This trap is sent to indicate that the password of one of the user's has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3006 | |
| luxNuserLevelModifiedTrap NOTIFICATION-TYPE This trap is sent to indicate that the privilege level of one of the user's has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3007 | |
| luxNsystemNameChangeTrap NOTIFICATION-TYPE This trap is sent to indicate that the name of the system has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3008 | |
| luxNcardAddedTrap NOTIFICATION-TYPE This trap is sent to indicate that a new card has been added to the system through either CLI/SNMP in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3009 | |
| luxNcardDeletedTrap NOTIFICATION-TYPE This trap is sent to indicate that a card has been deleted from the system through either CLI/SNMP in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3010 | |
| luxNmpmRedundancySwitchOverTrap NOTIFICATION-TYPE This trap is sent to indicate that a mpm switchover has occurred. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3011 | |
| luxNconnectionAddedTrap NOTIFICATION-TYPE This trap is sent to indicate that a connectino has been added to an ofcm/ofcd card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3012 | |
| luxNconnectionDeletedTrap NOTIFICATION-TYPE This trap is sent to indicate that a connection has been deleted from an ofcm/ofcd card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3013 | |
| luxNipAddressChangedTrap NOTIFICATION-TYPE This trap is sent to indicate that the IP address has been changed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3014 | |
| luxNipNetmaskChangedTrap NOTIFICATION-TYPE This trap is sent to indicate that the netmask has been changed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3015 | |
| luxNdefaultGatewayChangedTrap NOTIFICATION-TYPE This trap is sent to indicate that the default gateway has been changed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3016 | |
| luxNGetCommunityChangeTrap NOTIFICATION-TYPE This trap is sent to indicate that the getcommunity has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3017 | |
| luxNSetCommunityChangeTrap NOTIFICATION-TYPE This trap is sent to indicate that the setcommunity has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3018 | |
| luxNModuleResetTrap NOTIFICATION-TYPE This trap is sent to indicate that a module has been reset. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3019 | |
| luxNtopologyRediscoveredTrap NOTIFICATION-TYPE This trap is sent to indicate that the topology database has been rediscovered which is triggered through either CLI or snmp. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3020 | |
| luxNcolorsimEnabledTrap NOTIFICATION-TYPE This trap is sent to indicate that the ColorSIM feature has been enabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3021 | |
| luxNcolorsimDisabledTrap NOTIFICATION-TYPE This trap is sent to indicate that the ColorSIM feature has been disabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3022 | |
| luxNautoCutoffEnabledTrap NOTIFICATION-TYPE This trap is sent to indicate that the auto cutoff feature has been enabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3023 | |
| luxNautoCutoffDisabledTrap NOTIFICATION-TYPE This trap is sent to indicate that the auto cutoff feature has been disabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3024 | |
| luxNextAlarmsEnabledTrap NOTIFICATION-TYPE This trap is sent to indicate that the external alarm closures have been enabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3025 | |
| luxNextAlarmsDisabledTrap NOTIFICATION-TYPE This trap is sent to indicate that the external alarm closures have been disabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3026 | |
| luxNdlModuleActivatedTrap NOTIFICATION-TYPE This trap is sent to indicate that a module activation, switching to another module image version, has occurred. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3027 | |
| luxNhttpEnabledTrap NOTIFICATION-TYPE This trap is sent to indicate that the http server has been enabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3032 | |
| luxNhttpDisabledTrap NOTIFICATION-TYPE This trap is sent to indicate that the http server has been disabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3033 | |
| luxNstaticRouteAddedTrap NOTIFICATION-TYPE This trap is sent to indicate that a new route has been added to the system through either CLI/SNMP in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. The eveDescr field consists of trap description and the route information - local CC shelf, slot and destination IP address | 1.3.6.1.4.1.4253.0.3034 | |
| luxNstaticRouteDeletedTrap NOTIFICATION-TYPE This trap is sent to indicate that a route has been deleted from the system through either CLI/SNMP in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. The eveDescr field consists of trap description and the route information - local CC shelf, slot and destination IP address | 1.3.6.1.4.1.4253.0.3035 | |
| luxNupsrProtectionSwitchOverSrc NOTIFICATION-TYPE This trap is sent to indicate that UPSR protection switch over occurred on the source either through SNMP or CLI. If the module type is OCM for this trap, then after issuing this trap it goes into standby mode. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3036 | |
| luxNupsrProtectionSwitchOverDest NOTIFICATION-TYPE This trap is sent to indicate that UPSR protection switch over occurred on the destination either through SNMP or CLI. If the module type is OCM for this trap, then after issuing this trap it goes into active mode The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3037 | |
| luxNimnIpAddressChanged NOTIFICATION-TYPE This trap is sent to indicate that a IMN Ip address is successfully changed either through SNMP or CLI. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3038 | |
| luxNupsrNormal NOTIFICATION-TYPE This trap is sent to indicate that UPSR is successfully enabled either through SNMP or CLI on the system. This is done once UPSR functionality is normal on the system. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3039 | |
| luxNupsrDegraded NOTIFICATION-TYPE This trap is sent to indicate that UPSR is successfully disabled either through SNMP, CLI or SPI driver on the system. This is done after the UPSR functionality on the system is degraded The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3040 | |
| luxNusrOneAlarmAction NOTIFICATION-TYPE This trap is sent to indicate that user has performed acknowledgment/ unacknowledgment/Clearing of a single alarm in the alarm log either through SNMP or CLI . The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3041 | |
| luxNusrAllAlarmAction NOTIFICATION-TYPE This trap is sent to indicate that user has performed acknowledgment/ unacknowledgment/Clearing of all alarms in the alarm log either through SNMP or CLI . The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3042 | |
| luxNringConfigurationChanged NOTIFICATION-TYPE This trap is sent to indicate that the user has changed the ring configuration either through deletion or addition of ringId or pathId. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. The eveDescr field consists of trap description and the cross connect information | 1.3.6.1.4.1.4253.0.3047 | |
| luxNeventLogCleared NOTIFICATION-TYPE This trap is sent to indicate that the user has cleared the event log either through CLI or SNMP. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3048 | |
| luxNextAlarmInpTrap NOTIFICATION-TYPE This trap is sent when an user sets up alarm severity (crit/maj/minor/disable) on external alarm input. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3049 | |
| luxNextAudioAlarmTrap NOTIFICATION-TYPE This trap is sent when an user enables or disables audio alarm. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3050 | |
| luxNTrapHostConfigChangeTrap NOTIFICATION-TYPE This trap is sent when a trap host is added, deleted, or modified (port configuration). The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3051 | |
| luxNTrapHostImnRouteEnabled NOTIFICATION-TYPE | 1.3.6.1.4.1.4253.0.3052 | |
| luxNTrapHostImnRouteDisabled NOTIFICATION-TYPE | 1.3.6.1.4.1.4253.0.3053 | |
| luxNTrapHostAutoUpdateEnabled NOTIFICATION-TYPE | 1.3.6.1.4.1.4253.0.3054 | |
| luxNTrapHostAutoUpdateDisabled NOTIFICATION-TYPE | 1.3.6.1.4.1.4253.0.3055 | |
| luxNTrapPathAdded NOTIFICATION-TYPE This trap is sent when a path is configured. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3056 | |
| luxNTrapPathDeleted NOTIFICATION-TYPE This trap is sent when a path is deleted. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3057 | |
| luxNdlModuleActivateFailedTrap NOTIFICATION-TYPE This trap is sent when a module activation, switching to another module image version, has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3058 | |
| luxNLogServerAddedTrap NOTIFICATION-TYPE This trap is sent when a syslog server has been added. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3059 | |
| luxNLogServerDeletedTrap NOTIFICATION-TYPE This trap is sent when a syslog server has been deleted. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3060 | |
| luxNLogMaskChangedTrap NOTIFICATION-TYPE This trap is sent when the syslog mask has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3061 | |
| luxNRadiusAuthChangedTrap NOTIFICATION-TYPE This trap is sent when the radius authentication order has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3062 | |
| luxNRadiusDefaultRealmChangedTrap NOTIFICATION-TYPE This trap is sent when the radius default realm has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3063 | |
| luxNRadiusNasIdChangedTrap NOTIFICATION-TYPE This trap is sent when the radius NAS Identifier has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3064 | |
| luxNRadiusRetriesChangedTrap NOTIFICATION-TYPE This trap is sent when the radius retries has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3065 | |
| luxNRadiusServerAddedTrap NOTIFICATION-TYPE This trap is sent when a radius server has been added. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3066 | |
| luxNRadiusServerDeletedTrap NOTIFICATION-TYPE This trap is sent when radius server has been deleted. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3067 | |
| luxNRadiusServerModifiedTrap NOTIFICATION-TYPE This trap is sent when radius server port or secret has been modified. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3068 | |
| luxNRadiusTimeoutChangedTrap NOTIFICATION-TYPE This trap is sent when the radius timeout has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3069 | |
| luxNSshEnabledTrap NOTIFICATION-TYPE This trap is sent when the SSHD has been enabled. The source is a 4 or 5 tuple specifying the type location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3070 | |
| luxNSshDisabledTrap NOTIFICATION-TYPE This trap is sent when the SSHD has been disabled. The source is a 4 or 5 tuple specifying the type location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3071 | |
| luxNSshKeySizeSetTrap NOTIFICATION-TYPE This trap is sent when the SSHD key size has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3072 | |
| luxNSshMaxSessionsSetTrap NOTIFICATION-TYPE This trap is sent when the telnet/SSHD max sessions has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3073 | |
| luxNSshKeyGeneratedTrap NOTIFICATION-TYPE This trap is sent when the SSH DSS key has finished being generated. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.3074 | |
| luxNlogonIntruderTrap NOTIFICATION-TYPE This trap is sent to indicate that someone is repeatly trying to logon using an invalid password. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.4000 | |
| luxNlogonSessionStarted NOTIFICATION-TYPE This trap is sent to indicate that a user has logged into the MPM. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.4001 | |
| luxNlogonSessionClosed NOTIFICATION-TYPE This trap is sent to indicate that a user has logged out of the MPM. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.4002 | |
| luxNcpAuthenticationErrorTrap NOTIFICATION-TYPE This trap is sent to indicate that an invalid login attempt has been detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. | 1.3.6.1.4.1.4253.0.4003 |