MIBs Depot

LUXN-MIB

Registered at
1.3.6.1.4.1.4253
Namespace
zhone
Source file
LUXN-MIB
Digest
sha256:4fbc49f40a2be41bb29e061caabc3d67ffb0f8b66d907cb22a4d0850f9690678

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Gauge32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

LUXN-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
AlarmType
type
Boolean
type
CardCycleMode
type
CardLocation
type
CardName
type
CardShelf
type
CardSlot
type
CardState
type
CardStatus
type
CardType
type
ChassisType
type
DateAndTime
type
DownloadLocation
type
DownloadShelf
type
DownloadSlot
type
DownloadStatus
type
DownloadType
type
EncryptedCommunity
type
EntityName
type
EventBuffer
type
FileName
type
FlagType
type
FtpMode
type
HashedPasswd
type
HistoryMode
type
LinkName
type
LogonID
type
ModelNum
type
ModelString
type
NodeName
type
OSMode
type
OSState
type
PathIdName
type
PortIndex
type
RebootType
type
RedundancyMode
type
ReleaseDate
type
ResetType
type
RingIdName
type
SerialString
type
SfpSerialString
type
ShelfInput
type
SlotInput
type
Timezone
type
TrapStatus
type
UpdateOSMode
type
UserBuffer
type
VersionString
type
ZmsAdminString
type
ZmsFileName
type

Objects

NameOIDSyntaxAccessStatus
luxN
OBJECT-IDENTITY
1.3.6.1.4.1.4253
configuration
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1
manufacturing
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.1
mfgName
OBJECT-TYPE
Manufacturing name of the device. Up to 30 characters
1.3.6.1.4.1.4253.1.1.1DisplayString (SIZE(0..30))read-onlymandatory
mfgDate
OBJECT-TYPE
Date and Time of manufacturing of the chassis
1.3.6.1.4.1.4253.1.1.2DateAndTimeread-onlymandatory
mfgSerialNum
OBJECT-TYPE
Serial # of the Chassis.
1.3.6.1.4.1.4253.1.1.3SerialStringread-onlymandatory
mfgModelType
OBJECT-TYPE
Model type of the chassis. Up to 10 characters
1.3.6.1.4.1.4253.1.1.4ModelStringnot-accessiblemandatory
mfgDefaultID
OBJECT-TYPE
Default one-time user ID. This ID should be used for the first time access to the system. This ID will not be accepted once a real user ID is added.
1.3.6.1.4.1.4253.1.1.5LogonIDread-onlymandatory
mfgDfltPasswd
OBJECT-TYPE
Default one-time password to go with the default user ID. The password may contain non-printable characters up to 10 ASCII characters. Passwords are hashed and are for comparison only
1.3.6.1.4.1.4253.1.1.6HashedPasswdread-onlymandatory
mfgNumShelves
OBJECT-TYPE
Number of shelves in the chassis. This number reflects the number of rows of the table below. This number is automatically adjusted everytime a row is added to the table below.
1.3.6.1.4.1.4253.1.1.9CardShelfread-onlymandatory
mfgShelfTable
OBJECT-TYPE
This table represents the number of shelves and the number of slots per shelf in the chassis.
1.3.6.1.4.1.4253.1.1.10not-accessiblemandatory
mfgShelfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.1.10.1not-accessiblemandatory
mfgShelfID
OBJECT-TYPE
Integer ID of each shelf in the chassis. The shelf number is always one for both GM1608 and GM3217. In the case of of GM3234, the bottom shelf is 1 while the top shelf is 2. As for GMX128, the order of numbering is from the top shelf to the bottom shelf. In other words, the top shelf is assigned 1.
1.3.6.1.4.1.4253.1.1.10.1.1CardShelfread-onlymandatory
mfgNumSlots
OBJECT-TYPE
total number of slots in a given shelf.
1.3.6.1.4.1.4253.1.1.10.1.2CardSlotread-onlymandatory
mfgCRCChecksum
OBJECT-TYPE
32 bit CRC of the manufacturing section. This CRC is automatically calculated everytime information is updated from the manufacturing section. The manufacturing section is static once the chassis leaves the LuxN manufacturing premise.
1.3.6.1.4.1.4253.1.1.11DisplayString (SIZE(0..8))read-onlymandatory
mfgChassisType
OBJECT-TYPE
Type of chassis.
1.3.6.1.4.1.4253.1.1.12ChassisTyperead-onlymandatory
mfgPsType
OBJECT-TYPE
Type of power supplies.
1.3.6.1.4.1.4253.1.1.13INTEGER {dcOny(1), acOnly(2), mixedDcAc(3), unknown(4)}read-onlymandatory
mfgCleiNum
OBJECT-TYPE
CLEI number for the chassis.
1.3.6.1.4.1.4253.1.1.14DisplayStringread-onlymandatory
cp
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.2
cpIpAddress
OBJECT-TYPE
IP Address of the Active Communication Processor
1.3.6.1.4.1.4253.1.2.1IpAddressread-writemandatory
cpNetMask
OBJECT-TYPE
Net mask for the Active Communication Processor
1.3.6.1.4.1.4253.1.2.2IpAddressread-writemandatory
cpMIBVersion
OBJECT-TYPE
Version of the LuxN MIB implemented by this device. This value may be reset everytime a new CP code is downloaded.
1.3.6.1.4.1.4253.1.2.3VersionStringread-onlymandatory
cpBootPromVer
OBJECT-TYPE
The current version string of the Boot PROM code
1.3.6.1.4.1.4253.1.2.4VersionStringread-onlymandatory
cpROMSize
OBJECT-TYPE
Total Size of the ROM in Kilobyes
1.3.6.1.4.1.4253.1.2.5INTEGER (1..16384)not-accessiblemandatory
cpNumSubDiv
OBJECT-TYPE
Number of the subdivisions of the ROM.
1.3.6.1.4.1.4253.1.2.6INTEGER (1..20)read-onlymandatory
cpSubDivTable
OBJECT-TYPE
This table represents the number of sub divisions and the size of each subdivision in ROM memory
1.3.6.1.4.1.4253.1.2.7not-accessiblemandatory
cpSubDivEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.2.7.1not-accessiblemandatory
cpSubDivIndex
OBJECT-TYPE
Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
1.3.6.1.4.1.4253.1.2.7.1.1INTEGER (1..20)read-onlymandatory
cpSubDivDescr
OBJECT-TYPE
Display Name of each Sub Division in ROM
1.3.6.1.4.1.4253.1.2.7.1.2DisplayString (SIZE(0..20))read-onlymandatory
cpSubDivSize
OBJECT-TYPE
Size of each sub division in ROM in bytes
1.3.6.1.4.1.4253.1.2.7.1.3INTEGER (1..3145728)read-onlymandatory
cpSubDivOffset
OBJECT-TYPE
Starting address of each sub division in the ROM in HEX notation.
1.3.6.1.4.1.4253.1.2.7.1.4OCTET STRING (SIZE(0..8))not-accessiblemandatory
cpSubDivImgVersion
OBJECT-TYPE
Display Version of each Images in ROM.
1.3.6.1.4.1.4253.1.2.7.1.5DisplayStringread-onlymandatory
cpSubDivImgDBVersion
OBJECT-TYPE
Display Database Version of each Images in ROM.
1.3.6.1.4.1.4253.1.2.7.1.6DisplayStringread-onlymandatory
cpTable
OBJECT-TYPE
This table represents the information for each active or standby communication processor
1.3.6.1.4.1.4253.1.2.8not-accessiblemandatory
cpEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.2.8.1not-accessiblemandatory
cpCardShelf
OBJECT-TYPE
The shelf the card is in.
1.3.6.1.4.1.4253.1.2.8.1.1CardShelfread-onlymandatory
cpCardSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.1.2.8.1.2CardSlotread-onlymandatory
cpMode
OBJECT-TYPE
Type of the communication processor. The valid types are Active or Standby.
1.3.6.1.4.1.4253.1.2.8.1.3RedundancyModeread-onlymandatory
cpDsgntdMode
OBJECT-TYPE
Designation Type of the communication processor. The valid types are Active or Standby.
1.3.6.1.4.1.4253.1.2.8.1.4RedundancyModeread-onlymandatory
cpState
OBJECT-TYPE
The state of the CP card.
1.3.6.1.4.1.4253.1.2.8.1.5CardStateread-onlymandatory
cpMacAddr
OBJECT-TYPE
MAC address of the Communication processor in HEX
1.3.6.1.4.1.4253.1.2.8.1.6OCTET STRING (SIZE(0..6))read-onlymandatory
cpName
OBJECT-TYPE
Display (Network) name of the Communication processor
1.3.6.1.4.1.4253.1.2.8.1.7DisplayString (SIZE(0..32))read-writemandatory
cpMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the CP card
1.3.6.1.4.1.4253.1.2.8.1.8DateAndTimenot-accessiblemandatory
cpSerialNum
OBJECT-TYPE
Serial # of the CP card.
1.3.6.1.4.1.4253.1.2.8.1.9SerialStringread-onlymandatory
cpModelType
OBJECT-TYPE
Model type of the CP.
1.3.6.1.4.1.4253.1.2.8.1.10CardTyperead-onlymandatory
cpFWVersionID
OBJECT-TYPE
The current version string of the CP FW code
1.3.6.1.4.1.4253.1.2.8.1.11VersionStringread-onlymandatory
cpSetState
OBJECT-TYPE
Instruct the CP to do a warmboot. A get on this will always return an other.
1.3.6.1.4.1.4253.1.2.8.1.12RebootTyperead-writemandatory
cpHWName
OBJECT-TYPE
Display Hardware name of the CP Card.
1.3.6.1.4.1.4253.1.2.8.1.13DisplayString (SIZE(0..32))read-onlymandatory
cpCleiNum
OBJECT-TYPE
CLEI number of the mux/dmux Card.
1.3.6.1.4.1.4253.1.2.8.1.14DisplayStringread-onlymandatory
cpModelNum
OBJECT-TYPE
Model number of the CP card. Up to 15 characters
1.3.6.1.4.1.4253.1.2.8.1.15DisplayStringread-onlymandatory
cpSetMode
OBJECT-TYPE
Toggle the Active/Standby mode of the active CP.
1.3.6.1.4.1.4253.1.2.9RedundancyModeread-writemandatory
cpSNMPTrapHost1
OBJECT-TYPE
IP Address of the first SNMP Trap host. A NULL IP address means no TRAP should be sent to this address. Duplicate IP addresses will be rejected.
1.3.6.1.4.1.4253.1.2.10IpAddressread-writemandatory
cpSNMPTrapHost2
OBJECT-TYPE
IP Address of the second SNMP Trap host. A NULL IP address means no TRAP should be sent to this address. Duplicate IP addresses will be rejected.
1.3.6.1.4.1.4253.1.2.11IpAddressread-writemandatory
cpSNMPTrapHost3
OBJECT-TYPE
IP Address of the third SNMP Trap host. A NULL IP address means no TRAP should be sent to this address. Duplicate IP addresses will be rejected.
1.3.6.1.4.1.4253.1.2.12IpAddressread-writemandatory
cpSNMPSendTrap
OBJECT-TYPE
If set to true, traps will be sent out. If set to false, traps will not be sent out. This variable is reset to true (enable) on each boot cycle.
1.3.6.1.4.1.4253.1.2.13Booleanread-writemandatory
cpGateway
OBJECT-TYPE
Gateway IP Address of the Active Communication Processor. A NULL IP address means Gateway hasn't been configured.
1.3.6.1.4.1.4253.1.2.14IpAddressread-writemandatory
cpMaxSessions
OBJECT-TYPE
Maximum allowed Telnet Sessions on the Active Communication Processor. Valid values are 1 to 6.
1.3.6.1.4.1.4253.1.2.15INTEGER (1..6)read-writemandatory
cpSessionTimeout
OBJECT-TYPE
Maximum timeout (in seconds) that can be set for a Telnet session on the Active Communication Processor. Valid values are greater than 30 secs.
1.3.6.1.4.1.4253.1.2.16INTEGERread-writemandatory
cpDate
OBJECT-TYPE
Current Date on the Active Communication Processor. The format is in the form of mm-dd-yy in which mm is the two digit month, dd is the two digit day of the month, and yy is the two digit year.
1.3.6.1.4.1.4253.1.2.17DateAndTimeread-writemandatory
cpTime
OBJECT-TYPE
Current Time on the Active Communication Processor. The format is in the form of hh:mm:ss in which hh is the hour, mm is the minute and ss is the second. The valid values for hour goes from 0 to 23. In order to work with LuxN NMS, it needs to be set to GMT time
1.3.6.1.4.1.4253.1.2.18DateAndTimeread-writemandatory
cpGetCommunity
OBJECT-TYPE
User configurable SNMP Get Community String.
1.3.6.1.4.1.4253.1.2.19EncryptedCommunityread-writemandatory
cpSetCommunity
OBJECT-TYPE
User Configurable SNMP Set Community String.
1.3.6.1.4.1.4253.1.2.20EncryptedCommunityread-writemandatory
cpSystemName
OBJECT-TYPE
User Configurable System Name.
1.3.6.1.4.1.4253.1.2.21DisplayString (SIZE(0..59))read-writemandatory
cpSNMPTrapCommunity1
OBJECT-TYPE
User configurable trap community string for first trap host. Will return an error if the corresponding trap host is invalid or not set.
1.3.6.1.4.1.4253.1.2.22EncryptedCommunityread-writemandatory
cpSNMPTrapCommunity2
OBJECT-TYPE
User configurable trap community string for second trap host. Will return an error if the corresponding trap host is invalid or not set.
1.3.6.1.4.1.4253.1.2.23EncryptedCommunityread-writemandatory
cpSNMPTrapCommunity3
OBJECT-TYPE
User configurable trap community string for third trap host. Will return an error if the corresponding trap host is invalid or not set.
1.3.6.1.4.1.4253.1.2.24EncryptedCommunityread-writemandatory
cpHttp
OBJECT-TYPE
HTTP server enabled or not.
1.3.6.1.4.1.4253.1.2.25INTEGER {enabled(1), disabled(2)}not-accessiblemandatory
cpIMNIpAddress
OBJECT-TYPE
IMN Ip address. Use for IP/IWM
1.3.6.1.4.1.4253.1.2.26IpAddressread-writemandatory
cpUpsrMode
OBJECT-TYPE
UPSR mode: enable and disable.
1.3.6.1.4.1.4253.1.2.27INTEGER {enable(1), disable(2)}read-writemandatory
cpAutoModuleUpdate
OBJECT-TYPE
Flag to automatically enable/disable module update.
1.3.6.1.4.1.4253.1.2.28INTEGER {enable(1), disable(2)}read-writemandatory
cpSNMPTrapHost4
OBJECT-TYPE
IP Address of the fourth SNMP Trap host. A NULL IP address means no TRAP should be sent to this address. Duplicate IP addresses will be rejected.
1.3.6.1.4.1.4253.1.2.29IpAddressread-writemandatory
cpSNMPTrapHost5
OBJECT-TYPE
IP Address of the fifth SNMP Trap host. A NULL IP address means no TRAP should be sent to this address. Duplicate IP addresses will be rejected.
1.3.6.1.4.1.4253.1.2.30IpAddressread-writemandatory
cpSNMPTrapCommunity4
OBJECT-TYPE
User configurable trap community string for fourth trap host. Will return an error if the corresponding trap host is invalid or not set.
1.3.6.1.4.1.4253.1.2.31EncryptedCommunityread-writemandatory
cpSNMPTrapCommunity5
OBJECT-TYPE
User configurable trap community string for fifth trap host. Will return an error if the corresponding trap host is invalid or not set.
1.3.6.1.4.1.4253.1.2.32EncryptedCommunityread-writemandatory
cpSNMPTrapHostPort1
OBJECT-TYPE
User configurable trap port for the first trap host. Default value is 162
1.3.6.1.4.1.4253.1.2.33INTEGER (0..65534)read-writemandatory
cpSNMPTrapHostPort2
OBJECT-TYPE
User configurable trap port for the second trap host. Default value is 162
1.3.6.1.4.1.4253.1.2.34INTEGER (0..65534)read-writemandatory
cpSNMPTrapHostPort3
OBJECT-TYPE
User configurable trap port for the third trap host. Default value is 162
1.3.6.1.4.1.4253.1.2.35INTEGER (0..65534)read-writemandatory
cpSNMPTrapHostPort4
OBJECT-TYPE
User configurable trap port for the fourth trap host. Default value is 162
1.3.6.1.4.1.4253.1.2.36INTEGER (0..65534)read-writemandatory
cpSNMPTrapHostPort5
OBJECT-TYPE
User configurable trap port for the fifth trap host. Default value is 162
1.3.6.1.4.1.4253.1.2.37INTEGER (0..65534)read-writemandatory
cpRedunSubDivTable
OBJECT-TYPE
This table represents the number of sub divisions and the size of each subdivision in ROM memory of redundant (standby) MPM
1.3.6.1.4.1.4253.1.2.38not-accessiblemandatory
cpRedunSubDivEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.2.38.1not-accessiblemandatory
cpRedunSubDivIndex
OBJECT-TYPE
Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
1.3.6.1.4.1.4253.1.2.38.1.1INTEGER (1..20)read-onlymandatory
cpRedunSubDivDescr
OBJECT-TYPE
Display Name of each Sub Division in ROM
1.3.6.1.4.1.4253.1.2.38.1.2DisplayString (SIZE(0..20))read-onlymandatory
cpRedunSubDivImgVersion
OBJECT-TYPE
Display Version of each Images in ROM.
1.3.6.1.4.1.4253.1.2.38.1.3DisplayStringread-onlymandatory
cpRedunSubDivImgDBVersion
OBJECT-TYPE
Display Database Version of each Images in ROM.
1.3.6.1.4.1.4253.1.2.38.1.4DisplayStringread-onlymandatory
cpTimezone
OBJECT-TYPE
Specifies the internation time zone used by the MPM to determine system time. The time zone is only used to system time calculations when NTP is enabled
1.3.6.1.4.1.4253.1.2.39Timezoneread-writemandatory
cpNtpState
OBJECT-TYPE
Specifies whether NTP support is enabled or disabled.
1.3.6.1.4.1.4253.1.2.40INTEGER {enabled(1), disabled(2)}read-writemandatory
cpNtpTimeserver
OBJECT-TYPE
Specifies the NTP time server queries for updates.
1.3.6.1.4.1.4253.1.2.41IpAddressread-writemandatory
cpNtpUpdateInterval
OBJECT-TYPE
Specifies the NTP time update interval in minutes.
1.3.6.1.4.1.4253.1.2.42INTEGER (5..1440)read-writemandatory
cpTelnetClient
OBJECT-TYPE
Enable/disable telnet client for active telnet sessions.
1.3.6.1.4.1.4253.1.2.43INTEGER {enable(1), disable(2)}read-writemandatory
cpLogMask
OBJECT-TYPE
Set the log mask. The masks are equivalent to syslog priorities.
1.3.6.1.4.1.4253.1.2.44INTEGER {disabled(1), emerg(2), alert(3), crit(4), err(5), warn(6), notice(7), info(8), debug(9)}read-writemandatory
cpLogServer1
OBJECT-TYPE
IP Address of the first log server. A NULL IP address will remove this entry. Duplicate IP addresses will be rejected.
1.3.6.1.4.1.4253.1.2.45IpAddressread-writemandatory
cpLogServer2
OBJECT-TYPE
IP Address of the first log server. A NULL IP address will remove this entry. Duplicate IP addresses will be rejected.
1.3.6.1.4.1.4253.1.2.46IpAddressread-writemandatory
cpLogServer3
OBJECT-TYPE
IP Address of the first log server. A NULL IP address will remove this entry. Duplicate IP addresses will be rejected.
1.3.6.1.4.1.4253.1.2.47IpAddressread-writemandatory
cpLogServer4
OBJECT-TYPE
IP Address of the first log server. A NULL IP address will remove this entry. Duplicate IP addresses will be rejected.
1.3.6.1.4.1.4253.1.2.48IpAddressread-writemandatory
cpLogServer5
OBJECT-TYPE
IP Address of the first log server. A NULL IP address will remove this entry. Duplicate IP addresses will be rejected.
1.3.6.1.4.1.4253.1.2.49IpAddressread-writemandatory
cc
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.3
ccBootPromVer
OBJECT-TYPE
The current version string of the CC Boot PROM code
1.3.6.1.4.1.4253.1.3.1VersionStringnot-accessiblemandatory
ccROMSize
OBJECT-TYPE
Total Size of the CC ROM in Kilobyes
1.3.6.1.4.1.4253.1.3.2INTEGER (0..1024)not-accessiblemandatory
ccNumSubDiv
OBJECT-TYPE
Number of the subdivisions of the ROM.
1.3.6.1.4.1.4253.1.3.3INTEGER (0..20)not-accessiblemandatory
ccSubDivTable
OBJECT-TYPE
This table represents the number of sub divisions and the size of each subdivision in ROM memory
1.3.6.1.4.1.4253.1.3.4not-accessiblemandatory
ccSubDivEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.3.4.1not-accessiblemandatory
ccSubDivIndex
OBJECT-TYPE
Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
1.3.6.1.4.1.4253.1.3.4.1.1INTEGER (1..20)not-accessiblemandatory
ccSubDivDescr
OBJECT-TYPE
Display Name of each Sub Division in ROM
1.3.6.1.4.1.4253.1.3.4.1.2DisplayString (SIZE(0..20))not-accessiblemandatory
ccSubDivSize
OBJECT-TYPE
Size of each sub division in ROM in kilobytes
1.3.6.1.4.1.4253.1.3.4.1.3INTEGER (1..1024)not-accessiblemandatory
ccSubDivOffset
OBJECT-TYPE
Starting address of each sub division in the ROM in HEX notation.
1.3.6.1.4.1.4253.1.3.4.1.4OCTET STRING (SIZE(0..8))not-accessiblemandatory
ccNumber
OBJECT-TYPE
Number of CC rows in the following table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.3.5INTEGERread-onlymandatory
ccTable
OBJECT-TYPE
This table represents the information for each channel card
1.3.6.1.4.1.4253.1.3.6not-accessiblemandatory
ccEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.3.6.1not-accessiblemandatory
ccCardLocation
OBJECT-TYPE
Location of the card. Valid values are: Local in the same chassis, or remote to this chassis
1.3.6.1.4.1.4253.1.3.6.1.1CardLocationread-onlymandatory
ccCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2
1.3.6.1.4.1.4253.1.3.6.1.2CardShelfread-onlymandatory
ccCardSlot
OBJECT-TYPE
The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.3.6.1.3SlotInputread-writemandatory
ccMfgDate
OBJECT-TYPE
Date and Time of calibration of the CC card
1.3.6.1.4.1.4253.1.3.6.1.4DateAndTimeread-onlymandatory
ccSerialNum
OBJECT-TYPE
Serial # of the CC card.
1.3.6.1.4.1.4253.1.3.6.1.5SerialStringread-onlymandatory
ccModelType
OBJECT-TYPE
Model type of the channel card.
1.3.6.1.4.1.4253.1.3.6.1.6CardTyperead-onlymandatory
ccName
OBJECT-TYPE
User configurable name of the channel card
1.3.6.1.4.1.4253.1.3.6.1.7CardNameread-writemandatory
ccFWVersionID
OBJECT-TYPE
The current version string of the CC FW code
1.3.6.1.4.1.4253.1.3.6.1.8VersionStringread-onlymandatory
ccMfgBiasCurrent
OBJECT-TYPE
Bias current for the optical laser. This is the preset manufacturing value
1.3.6.1.4.1.4253.1.3.6.1.9INTEGERread-onlymandatory
ccMfgModulation
OBJECT-TYPE
The frequency modulation for the optical laser. This value is the preset manufacturing value.
1.3.6.1.4.1.4253.1.3.6.1.10INTEGERread-onlymandatory
ccMfgApc
OBJECT-TYPE
The APC value. This value is the preset manufacturing value
1.3.6.1.4.1.4253.1.3.6.1.11INTEGERread-onlymandatory
ccMfgIwmModulation
OBJECT-TYPE
The frequency modulation for the IWM channel. This value is the preset manufacturing value
1.3.6.1.4.1.4253.1.3.6.1.12INTEGERread-onlymandatory
ccMfgRefClock
OBJECT-TYPE
The value of the reference clock in decimal notation. For a given value, like 1660-EN, the actual value is 16.60-EN. In otherwords, assume a two digit decimal point, plus any appropriate scaling factor. This value is the preset manufacturing value.
1.3.6.1.4.1.4253.1.3.6.1.13INTEGER {en1660(1), en1944(2), en1953(3)}not-accessiblemandatory
ccMfgClockDiv
OBJECT-TYPE
The clock divisor. Values are 1250, 622 or 155 in the appropriate clock frequency scale.
1.3.6.1.4.1.4253.1.3.6.1.14INTEGER {dout-1250(1), dout-622(2), dout-155(3)}not-accessiblemandatory
ccBandwidth
OBJECT-TYPE
The bandwidth of the channel card.
1.3.6.1.4.1.4253.1.3.6.1.15INTEGER {oc3(1), oc12(2), oc48(3), gbEthernet(4), fibreChannel(5), oc192(6), gbE10(9), fibreChannelX2(10)}read-writemandatory
ccSetState
OBJECT-TYPE
Instruct the CC to do a warmboot or loopback. A get on this will always return an other.
1.3.6.1.4.1.4253.1.3.6.1.16INTEGER {other(1), warmboot(2), enableLoopback(3), disableLoopback(4)}read-writemandatory
connMuxChassis
OBJECT-TYPE
The connected mux chassis.
1.3.6.1.4.1.4253.1.3.6.1.17INTEGERnot-accessiblemandatory
connMuxShelf
OBJECT-TYPE
The connected mux shelf.
1.3.6.1.4.1.4253.1.3.6.1.18ShelfInputread-onlymandatory
connMuxSlot
OBJECT-TYPE
The connected mux slot.
1.3.6.1.4.1.4253.1.3.6.1.19SlotInputread-onlymandatory
connMuxPort
OBJECT-TYPE
The connected mux port.
1.3.6.1.4.1.4253.1.3.6.1.20INTEGERread-onlymandatory
connDemuxChassis
OBJECT-TYPE
The connected demux chassis.
1.3.6.1.4.1.4253.1.3.6.1.21INTEGERnot-accessiblemandatory
connDemuxShelf
OBJECT-TYPE
The connected demux shelf.
1.3.6.1.4.1.4253.1.3.6.1.22ShelfInputread-onlymandatory
connDemuxSlot
OBJECT-TYPE
The connected demux slot.
1.3.6.1.4.1.4253.1.3.6.1.23SlotInputread-onlymandatory
connDemuxPort
OBJECT-TYPE
The connected demux port.
1.3.6.1.4.1.4253.1.3.6.1.24INTEGERread-onlymandatory
ccModelNum
OBJECT-TYPE
Model number of the CC card. Up to 15 characters
1.3.6.1.4.1.4253.1.3.6.1.25DisplayStringread-onlymandatory
ccLinkITUNum
OBJECT-TYPE
Link ITU number of the CC card. Up to 15 characters
1.3.6.1.4.1.4253.1.3.6.1.26DisplayStringread-onlymandatory
ccLinkWavelength
OBJECT-TYPE
Link Wavelength of the CC card
1.3.6.1.4.1.4253.1.3.6.1.27DisplayString (SIZE(0..15))read-onlymandatory
ccLaserType
OBJECT-TYPE
Laser Type of the Channel Card.
1.3.6.1.4.1.4253.1.3.6.1.28INTEGER {uncooled(1), cooled(2)}read-onlymandatory
ccRecvDiode
OBJECT-TYPE
Receive Diode of the Channel Card.
1.3.6.1.4.1.4253.1.3.6.1.29INTEGER {apd(1), pin(2)}read-onlymandatory
ccLinkAutoDisable
OBJECT-TYPE
Flag to enable/disable the CPE link when the threshold value crosses the lower hysteresis limit. The default value is disable. CPE disable with CPE Rx pass through is identical to normal CPE disable with the added feature that the remote CPE Tx will be disabled if a loss of light condition is detected on the local CPE Rx.
1.3.6.1.4.1.4253.1.3.6.1.30INTEGER {enable(1), disable(2), enableCpeRxPassThru(3)}read-writemandatory
ccLinkName
OBJECT-TYPE
Link name for fiber between the local and the remote cc card.
1.3.6.1.4.1.4253.1.3.6.1.31LinkNameread-writemandatory
ccCsimModule
OBJECT-TYPE
Whether colorSIM module is physically present, not installed or preconfigured.
1.3.6.1.4.1.4253.1.3.6.1.32INTEGER {installed(1), notinstalled(2), preconfigured(3)}read-onlymandatory
ccHWName
OBJECT-TYPE
Display Hardware name of the CC Card.
1.3.6.1.4.1.4253.1.3.6.1.33CardNameread-onlymandatory
ccBackpackModule
OBJECT-TYPE
Presence of Backpack module, installed or not Installed.
1.3.6.1.4.1.4253.1.3.6.1.34INTEGER {installed(1), notInstalled(2)}read-onlymandatory
ccBackpackRxITUNumber
OBJECT-TYPE
Rx ITU number of backpack.
1.3.6.1.4.1.4253.1.3.6.1.35DisplayStringread-onlymandatory
ccBackpackTxITUNumber
OBJECT-TYPE
Tx ITU number of backpack.
1.3.6.1.4.1.4253.1.3.6.1.36DisplayStringread-onlymandatory
ccBackpackRxInsertionLoss
OBJECT-TYPE
Rx Insertion loss of backpack.
1.3.6.1.4.1.4253.1.3.6.1.37DisplayStringread-onlymandatory
ccBackpackTxInsertionLoss
OBJECT-TYPE
Tx Insertion loss of backpack.
1.3.6.1.4.1.4253.1.3.6.1.38DisplayStringread-onlymandatory
ccBackpackRxExpressLoss
OBJECT-TYPE
Rx Express loss of backpack.
1.3.6.1.4.1.4253.1.3.6.1.39DisplayStringread-onlymandatory
ccBackpackTxExpressLoss
OBJECT-TYPE
Tx Express loss of backpack.
1.3.6.1.4.1.4253.1.3.6.1.40DisplayStringread-onlymandatory
ccSwitchByShelfSlot
OBJECT-TYPE
Initiate manual UPSR switching by shelf and slot.
1.3.6.1.4.1.4253.1.3.6.1.41DisplayString (SIZE(0..10))read-writemandatory
ccPathID
OBJECT-TYPE
Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
1.3.6.1.4.1.4253.1.3.6.1.42PathIdNameread-writemandatory
ccCpeDisableThreshold
OBJECT-TYPE
CPE Disable Threshold (Link Rx Power) in dBm. The limit is from -32 to -8, but input should be an absolute value if using mib browser. A value of 0 in this field indicates that UPSR is not supported. This value will not take affect until ccLinkAutoDisable has been enabled.
1.3.6.1.4.1.4253.1.3.6.1.43INTEGERread-writemandatory
ccCpeReEnableThreshold
OBJECT-TYPE
CPE Re-enable threshold (Link Rx Power) in dBm. The limit is from -31 to -7, but input should be an absolute value if using mib browser. A value of 0 in this field indicates that UPSR is not supported. This value will not take affect until ccLinkAutoDisable has been enabled.
1.3.6.1.4.1.4253.1.3.6.1.44INTEGERread-writemandatory
connTxNonMuxDmuxCardType
OBJECT-TYPE
Type of module connected to Tx port of OCM.
1.3.6.1.4.1.4253.1.3.6.1.45CardTyperead-onlymandatory
connTxNonMuxDmuxPort
OBJECT-TYPE
Conn port for CC's Tx port.Possible values based on card types that can connect to OCM are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCMU/OCMITU/MCMT1/MCME1/OCM10G/OCM10G: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=15501590/, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx.
1.3.6.1.4.1.4253.1.3.6.1.46INTEGERread-onlymandatory
connTxNonMuxDmuxShelf
OBJECT-TYPE
The shelf the card conn to Tx port of OCM. Valid values are: 1 to 10.
1.3.6.1.4.1.4253.1.3.6.1.47ShelfInputread-onlymandatory
connTxNonMuxDmuxSlot
OBJECT-TYPE
The slot within the shelf the card conn to Tx port of OCM.
1.3.6.1.4.1.4253.1.3.6.1.48SlotInputread-onlymandatory
connRxNonMuxDmuxCardType
OBJECT-TYPE
Type of module connected to Rx port of OCM.
1.3.6.1.4.1.4253.1.3.6.1.49CardTyperead-onlymandatory
connRxNonMuxDmuxPort
OBJECT-TYPE
Conn port for CC's Rx port.Possible values based on card types that can connect to OCM are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCMU/OCMITU/MCMT1/MCME1/OCM10G/OCM10G: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=15501590/, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx.
1.3.6.1.4.1.4253.1.3.6.1.50INTEGERread-onlymandatory
connRxNonMuxDmuxShelf
OBJECT-TYPE
The shelf the card conn to Rx port of OCM. Valid values are: 1 to 10.
1.3.6.1.4.1.4253.1.3.6.1.51ShelfInputread-onlymandatory
connRxNonMuxDmuxSlot
OBJECT-TYPE
The slot within the shelf the card conn to Rx port of OCM.
1.3.6.1.4.1.4253.1.3.6.1.52SlotInputread-onlymandatory
ccUpsrMode
OBJECT-TYPE
UPSR mode for CC card: primary or backup. If not in upsr configuration, value is na. This value will not take affect until ccLinkAutoDisable has been enabled.
1.3.6.1.4.1.4253.1.3.6.1.53INTEGER {primary(1), backup(2), na(3)}read-writemandatory
ccPairShelf
OBJECT-TYPE
The shelf of other CC card in pair.
1.3.6.1.4.1.4253.1.3.6.1.54INTEGERread-writemandatory
ccPairSlot
OBJECT-TYPE
The slot of other CC card in pair. Input 0 to unpair OCMs and delete RSM connections if any.
1.3.6.1.4.1.4253.1.3.6.1.55INTEGERread-writemandatory
ccAdminState
OBJECT-TYPE
Administrative control over that cc card. Default value is enable. When disabled, no alarms/events gets generated. For remote CC, the default value is disabled
1.3.6.1.4.1.4253.1.3.6.1.56INTEGER {disable(1), enable(2), na(3)}read-writemandatory
ccRegenPairShelf
OBJECT-TYPE
The shelf of other CC card in OCM regeneration pair. This value will not take affect until ccLinkAutoDisable has been enabled.
1.3.6.1.4.1.4253.1.3.6.1.57INTEGERread-writemandatory
ccRegenPairSlot
OBJECT-TYPE
The slot of other CC card in OCM regeneration pair. Input 0 to unpair OCMs involved. This value will not take affect until ccLinkAutoDisable has been enabled.
1.3.6.1.4.1.4253.1.3.6.1.58INTEGERread-writemandatory
ccCleiNum
OBJECT-TYPE
CLEI number of the CC Card.
1.3.6.1.4.1.4253.1.3.6.1.59DisplayStringread-onlymandatory
connCpeTxMcmescShelf
OBJECT-TYPE
The connected MCMESC shelf.
1.3.6.1.4.1.4253.1.3.6.1.60ShelfInputread-onlymandatory
connCpeTxMcmescSlot
OBJECT-TYPE
The connected MCMESC slot.
1.3.6.1.4.1.4253.1.3.6.1.61SlotInputread-onlymandatory
connCpeTxMcmescPort
OBJECT-TYPE
The connected MCMESC port. 1=Link Tx, 2=Link Rx.
1.3.6.1.4.1.4253.1.3.6.1.62INTEGER {linktx(1), linkrx(2)}read-onlymandatory
connCpeRxMcmescShelf
OBJECT-TYPE
The connected MCMESC shelf.
1.3.6.1.4.1.4253.1.3.6.1.63ShelfInputread-onlymandatory
connCpeRxMcmescSlot
OBJECT-TYPE
The connected MCMESC slot.
1.3.6.1.4.1.4253.1.3.6.1.64SlotInputread-onlymandatory
connCpeRxMcmescPort
OBJECT-TYPE
The connected MCMESC port. 1=Link Tx, 2=Link Rx.
1.3.6.1.4.1.4253.1.3.6.1.65INTEGER {linktx(1), linkrx(2)}read-onlymandatory
ccNumPorts
OBJECT-TYPE
Total port numbers on each CC card.
1.3.6.1.4.1.4253.1.3.6.1.66INTEGERread-onlymandatory
mux
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.4
muxBootPromVer
OBJECT-TYPE
The current version string of the Mux Boot PROM code
1.3.6.1.4.1.4253.1.4.1VersionStringnot-accessiblemandatory
muxROMSize
OBJECT-TYPE
Total Size of the ROM in Kilobyes
1.3.6.1.4.1.4253.1.4.2INTEGER (0..1024)not-accessiblemandatory
muxNumSubDiv
OBJECT-TYPE
Number of the subdivisions of the ROM.
1.3.6.1.4.1.4253.1.4.3INTEGER (0..20)not-accessiblemandatory
muxSubDivTable
OBJECT-TYPE
This table represents the number of sub divisions and the size of each subdivision in ROM memory
1.3.6.1.4.1.4253.1.4.4not-accessiblemandatory
muxSubDivEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.4.4.1not-accessiblemandatory
muxSubDivIndex
OBJECT-TYPE
Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
1.3.6.1.4.1.4253.1.4.4.1.1INTEGER (0..20)not-accessiblemandatory
muxSubDivDescr
OBJECT-TYPE
Display Name of each Sub Division in ROM
1.3.6.1.4.1.4253.1.4.4.1.2DisplayString (SIZE(0..20))not-accessiblemandatory
muxSubDivSize
OBJECT-TYPE
Size of each sub division in ROM in kilobytes
1.3.6.1.4.1.4253.1.4.4.1.3INTEGER (0..1024)not-accessiblemandatory
muxSubDivOffset
OBJECT-TYPE
Starting address of each sub division in the ROM in HEX notation.
1.3.6.1.4.1.4253.1.4.4.1.4OCTET STRING (SIZE(0..8))not-accessiblemandatory
muxNumber
OBJECT-TYPE
Number of MUX rows in the following table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.4.5INTEGERread-onlymandatory
muxTable
OBJECT-TYPE
This table represents the information for each MUX card
1.3.6.1.4.1.4253.1.4.6not-accessiblemandatory
muxEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.4.6.1not-accessiblemandatory
muxCardLocation
OBJECT-TYPE
Location of the module. Valid values are: Local in the same chassis, or remote to this chassis
1.3.6.1.4.1.4253.1.4.6.1.1CardLocationread-onlymandatory
muxCardShelf
OBJECT-TYPE
The shelf the card is in.
1.3.6.1.4.1.4253.1.4.6.1.2CardShelfread-onlymandatory
muxCardSlot
OBJECT-TYPE
The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.4.6.1.3SlotInputread-writemandatory
muxModelNum
OBJECT-TYPE
Model number for module.
1.3.6.1.4.1.4253.1.4.6.1.4DisplayStringread-onlymandatory
muxMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the module
1.3.6.1.4.1.4253.1.4.6.1.5DateAndTimenot-accessiblemandatory
muxSerialNum
OBJECT-TYPE
Serial # of the module.
1.3.6.1.4.1.4253.1.4.6.1.6SerialStringread-onlymandatory
muxModelType
OBJECT-TYPE
Model type of the module
1.3.6.1.4.1.4253.1.4.6.1.7CardTyperead-onlymandatory
muxName
OBJECT-TYPE
User configurable name of the module
1.3.6.1.4.1.4253.1.4.6.1.8CardNameread-writemandatory
muxFWVersionID
OBJECT-TYPE
The current version string of the FW code
1.3.6.1.4.1.4253.1.4.6.1.9VersionStringread-onlymandatory
muxSetState
OBJECT-TYPE
Instruct the mux to do a warmboot. A get on this will always return an other.
1.3.6.1.4.1.4253.1.4.6.1.10RebootTyperead-writemandatory
muxNumPorts
OBJECT-TYPE
Total port numbers on each MUX card. Should be six
1.3.6.1.4.1.4253.1.4.6.1.11INTEGERread-onlymandatory
muxUpgradeFlag
OBJECT-TYPE
The MUX card's status is upgradable or not.
1.3.6.1.4.1.4253.1.4.6.1.12INTEGER {upgradable(1), notUpgradable(2)}read-onlymandatory
muxHWName
OBJECT-TYPE
Display Hardware name of the mux/dmux Card.
1.3.6.1.4.1.4253.1.4.6.1.13CardNameread-onlymandatory
muxPathID
OBJECT-TYPE
Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
1.3.6.1.4.1.4253.1.4.6.1.14PathIdNameread-writemandatory
muxAdminState
OBJECT-TYPE
Administrative control over that mux card. Default value is enable. When disabled, no alarms/events gets generated.
1.3.6.1.4.1.4253.1.4.6.1.15INTEGER {disable(1), enable(2), na(3)}read-writemandatory
muxCleiNum
OBJECT-TYPE
CLEI number of the mux/dmux Card.
1.3.6.1.4.1.4253.1.4.6.1.16DisplayStringread-onlymandatory
muxChannelSpacing
OBJECT-TYPE
ITU channel spacing for the mux/demux card. Only valid for MD100-40 and BD4 Modules.
1.3.6.1.4.1.4253.1.4.6.1.17INTEGERread-onlymandatory
muxStartItu
OBJECT-TYPE
First ITU channel supported by the module. Only valid for MD100-40 and BD4 Modules.
1.3.6.1.4.1.4253.1.4.6.1.18INTEGERread-onlymandatory
muxEndItu
OBJECT-TYPE
Last ITU channel supported by the module. Only valid for MD100-40 and BD4 Modules.
1.3.6.1.4.1.4253.1.4.6.1.19INTEGERread-onlymandatory
muxChannelsPerBand
OBJECT-TYPE
Number of channels per optical band supported by the module. Only valid for BD-4 and MD100-40 module.
1.3.6.1.4.1.4253.1.4.6.1.20INTEGERread-onlymandatory
muxBands
OBJECT-TYPE
Number of bands supported by the module. Only valid for BD-4 and MD100-40 module.
1.3.6.1.4.1.4253.1.4.6.1.21INTEGERread-onlymandatory
muxPortNumber
OBJECT-TYPE
Number of MUX's port rows in the following table. This number is automatically updated whenever a new row is added to the table below.Basically a product of # of mux cards and # of ports on each card. Hence it would have a value of 6, 12, 18 etc..
1.3.6.1.4.1.4253.1.4.7INTEGERread-onlymandatory
muxPortTable
OBJECT-TYPE
This table represents the information for each MUX card's port.
1.3.6.1.4.1.4253.1.4.8not-accessiblemandatory
muxPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.4.8.1not-accessiblemandatory
muxPortCardLocation
OBJECT-TYPE
Location of the MUX's port. Valid values are: Local in the same chassis, or remote to this chassis
1.3.6.1.4.1.4253.1.4.8.1.1CardLocationread-onlymandatory
muxPortCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.4.8.1.2CardShelfread-onlymandatory
muxPortCardSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.1.4.8.1.3SlotInputread-onlymandatory
muxPortIndex
OBJECT-TYPE
Port's index. Ports 1 through 4 can be use for connection with OCM family or MCMT1/MCME1 only.
1.3.6.1.4.1.4253.1.4.8.1.4INTEGERread-onlymandatory
muxWavelength
OBJECT-TYPE
Port's wavelength: either ITU number or actual wavelength in nm. Supported by all Mux modules except MD100-40 & BD4.
1.3.6.1.4.1.4253.1.4.8.1.5INTEGERread-onlymandatory
muxInsertLoss
OBJECT-TYPE
Mux Port insertion Loss range. Supported by all Mux modules except MD100-40 & BD4.
1.3.6.1.4.1.4253.1.4.8.1.6DisplayStringread-onlymandatory
muxConnCardType
OBJECT-TYPE
Module type connected to mux port. Supported by all Mux modules except MD100-40 & BD4.
1.3.6.1.4.1.4253.1.4.8.1.7CardTyperead-writemandatory
muxConnLocation
OBJECT-TYPE
The chassis's location of the card conn to. Supported by all Mux modules except MD100-40 & BD4.
1.3.6.1.4.1.4253.1.4.8.1.8CardLocationread-writemandatory
muxConnShelf
OBJECT-TYPE
The shelf the card conn to. Valid values are: 1 to 2. Supported by all Mux modules except MD100-40 & BD4.
1.3.6.1.4.1.4253.1.4.8.1.9ShelfInputread-writemandatory
muxConnSlot
OBJECT-TYPE
The slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0. Supported by all Mux modules except MD100-40 & BD4.
1.3.6.1.4.1.4253.1.4.8.1.10SlotInputread-writemandatory
muxConnPort
OBJECT-TYPE
Conn port for MUX/DMUX's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. Entry supported by all Mux modules except MD100-40 & BD4.
1.3.6.1.4.1.4253.1.4.8.1.11INTEGERread-writemandatory
muxPortType
OBJECT-TYPE
Type of the MUX's port. Supported by all Mux modules except MD100-40 & BD4.
1.3.6.1.4.1.4253.1.4.8.1.12INTEGER {mux(1), demux(2)}read-onlymandatory
muxConnChassisID
OBJECT-TYPE
Chassis ID of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the chassis Id of the local node. Supported by all Mux modules except MD100-40 & BD4.
1.3.6.1.4.1.4253.1.4.8.1.13DisplayString (SIZE(0..16))read-writemandatory
muxConnSystemName
OBJECT-TYPE
System Name of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the sysetem name of the local node. Supported by all Mux modules except MD100-40 & BD4.
1.3.6.1.4.1.4253.1.4.8.1.14DisplayString (SIZE(0..32))read-writemandatory
muxConnIpAddress
OBJECT-TYPE
IpAddress of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the IP address of the node. Supported by all Mux modules except MD100-40 & BD4.
1.3.6.1.4.1.4253.1.4.8.1.15IpAddressread-writemandatory
muxPortAvgInsertionLoss
OBJECT-TYPE
Average port insertion loss for the port category. Valid only for MD100-40 & BD4 modules.
1.3.6.1.4.1.4253.1.4.8.1.16DisplayStringread-onlymandatory
muxPortMaxInsertionLoss
OBJECT-TYPE
Maximum port insertion loss for the port category. Valid only for MD100-40 & BD4 modules.
1.3.6.1.4.1.4253.1.4.8.1.17DisplayStringread-onlymandatory
muxPortTapRatio
OBJECT-TYPE
Tap ratio for the port category. Valid only for MD100-40 & BD4 modules.
1.3.6.1.4.1.4253.1.4.8.1.18DisplayStringread-onlymandatory
ps
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.5
psNumber
OBJECT-TYPE
Number of PS (power supply) rows in the following table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.5.1INTEGERread-onlymandatory
psTable
OBJECT-TYPE
This table represents the information for each PS module.
1.3.6.1.4.1.4253.1.5.2not-accessiblemandatory
psEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.5.2.1not-accessiblemandatory
psID
OBJECT-TYPE
The module ID the ps module is in. Valid values are: 1 to 4
1.3.6.1.4.1.4253.1.5.2.1.1INTEGER (1..4)not-accessiblemandatory
psMode
OBJECT-TYPE
Mode of the PS module. Valid values are: active or standby
1.3.6.1.4.1.4253.1.5.2.1.2RedundancyModenot-accessiblemandatory
psMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the PS module.
1.3.6.1.4.1.4253.1.5.2.1.3DateAndTimenot-accessiblemandatory
psSerialNum
OBJECT-TYPE
Serial # of the PS module. Not Supported Yet.
1.3.6.1.4.1.4253.1.5.2.1.4SerialStringnot-accessiblemandatory
psModelType
OBJECT-TYPE
Model type of the PS module. Up to 10 characters. Not Supported Yet.
1.3.6.1.4.1.4253.1.5.2.1.5ModelStringnot-accessiblemandatory
download
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.6
dlFtpTable
OBJECT-TYPE
This table represents the information for each FTP server
1.3.6.1.4.1.4253.1.6.1not-accessiblemandatory
dlFtpEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.6.1.1not-accessiblemandatory
dlFtpIp
OBJECT-TYPE
The IP address of the FTP server.
1.3.6.1.4.1.4253.1.6.1.1.1IpAddressread-writemandatory
dlFtpLogonID
OBJECT-TYPE
The FTP user ID for this FTP server. Up to 15 chars.
1.3.6.1.4.1.4253.1.6.1.1.2LogonIDread-writemandatory
dlFtpPasswd
OBJECT-TYPE
Password for the above FTP Logon ID. This password is NOT hashed. Proper security access is required to set and view this element. Most FTP connections, however, are using anonymous logon ID with no special password requirements.
1.3.6.1.4.1.4253.1.6.1.1.3DisplayString (SIZE(0..20))read-writemandatory
dlFtpMode
OBJECT-TYPE
FTP server modes. The choices are: active or passive, active may be necessary for users behind a firewall.
1.3.6.1.4.1.4253.1.6.1.1.4FtpModeread-writemandatory
dlFtpPort
OBJECT-TYPE
FTP port. This port is used in conjunction with the FTP IP address for establishing a connection to the FTP server. Any valid IP port may be entered. Setting this element to zero (0) will cause the standard FTP port (21) to be used.
1.3.6.1.4.1.4253.1.6.1.1.5INTEGER (0..65535)read-writemandatory
dlPreQualTable
OBJECT-TYPE
This table represents the information for each PreQual table.
1.3.6.1.4.1.4253.1.6.2not-accessiblemandatory
dlPreQualEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.6.2.1not-accessiblemandatory
dlPreQualTypeVersion
OBJECT-TYPE
The Image type and version to be prequalified before downloading. The string format is : type,version. The prequal action will be taken after setting version.
1.3.6.1.4.1.4253.1.6.2.1.1DisplayString (SIZE(0..42))read-writemandatory
dlPreQualResult
OBJECT-TYPE
The result after comparing type and version of the selected download image with the compatibility matrix. The result is either compatible, incompatible or unknown version. (Not available at this time). The default is compatible.
1.3.6.1.4.1.4253.1.6.2.1.2INTEGER {compatible(1), incompatible(2), unknown-version(3)}read-onlymandatory
dlDownloadTable
OBJECT-TYPE
This table represents the information for download and activation.
1.3.6.1.4.1.4253.1.6.3not-accessiblemandatory
dlDownloadEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.6.3.1not-accessiblemandatory
dlType
OBJECT-TYPE
The Image type to be downloaded or to be activated. The valid values are: all, mpms, boot, macf, mcme1, mcmesc_code, mcmt1, mpm, ocm, ocm10g, oet, osam, osam_hp/lp, rsm, upsm, uob. When choosing all, all non-mpm images are downloaded, the dlLocation should be set to local, dlShelf and dlSlot should be set to 0, dlFilename should be set to the path under which all the non-mpm images are put. When choosing mpms, mpm's two associated images, boot and mpm run code image, are downloaded, the dlLocation should be set to local, dlShelf and dlSlot should be set to active mpm's shelf and slot, dlFilename should be set to the path under which the two images are put. To MCME1/MCMT1 modules, mcm_fpag image will automatically be downloaded when mcme1 or mcmt1 is selected.
1.3.6.1.4.1.4253.1.6.3.1.1DownloadTyperead-writemandatory
dlLocation
OBJECT-TYPE
The location to be downloaded or to be activated. The choices are: local, remote or both. (Only local and remote are supported at this time, LuxnOS has only local choice and is not supported yet. When dlType is set to all, only local is supported.
1.3.6.1.4.1.4253.1.6.3.1.2DownloadLocationread-writemandatory
dlShelf
OBJECT-TYPE
The destination shelf. When dlType is set to all, dlShelf should be set to 0.
1.3.6.1.4.1.4253.1.6.3.1.3DownloadShelfread-writemandatory
dlSlot
OBJECT-TYPE
The slot within the selected shelf. When dlType is set to all, dlSlot should be set to 0.
1.3.6.1.4.1.4253.1.6.3.1.4DownloadSlotread-writemandatory
dlFilename
OBJECT-TYPE
The filename and path of the file to be downloaded -up to 255 characters. When dlType is set to all, the dlFilename field should be set to the path of the directory where the non-mpm images are stored. When dlType is set to mpms, the dlFilename field should be set to the path of the directory where the boot and mpm images are stored. The download action (imageupdate) will be taken after setting the dlFilename field.
1.3.6.1.4.1.4253.1.6.3.1.5DisplayString (SIZE(0..255))read-writemandatory
dlActivate
OBJECT-TYPE
Activate the backup image at the selected location. To MCMESC, no, activateBackupFirmware, activateBackupFPGA and activateBackupFirmwareAndFPGA are applicable. To MCMT1/MCME1, no and activateBackupFirmwareAndFPGA are applicable. To other modules, no and activateBackupFirmware are applicable. When choosing activateForAllLineCards, the dlShelf and dlSlot sholud be set to 0.
1.3.6.1.4.1.4253.1.6.3.1.6INTEGER {no(1), activateBackupFirmware(2), activateBackupFPGA(3), activateBackupFirmwareAndFPGA(4), activateForAllLineCards(5)}read-writemandatory
dlExportType
OBJECT-TYPE
The image indicated by dlType is to be exported to the dlFilename using FTP. Ths element is reset to none(1) after each export.
1.3.6.1.4.1.4253.1.6.3.1.7INTEGER {import(1), export(2)}read-writemandatory
dlOSTable
OBJECT-TYPE
This table represents the information for LuxnOS table.
1.3.6.1.4.1.4253.1.6.4not-accessiblemandatory
dlOSEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.6.4.1not-accessiblemandatory
dlOSIndex
OBJECT-TYPE
The Integer ID for each LuxnOS.
1.3.6.1.4.1.4253.1.6.4.1.1INTEGER (1..2)not-accessiblemandatory
dlOSVersion
OBJECT-TYPE
Display the LuxnOS version.
1.3.6.1.4.1.4253.1.6.4.1.2VersionStringnot-accessiblemandatory
dlOSState
OBJECT-TYPE
Display the LuxnOS state: operating(1) is the current operating LuxnOS, backup(2)is the backup LuxnOS.
1.3.6.1.4.1.4253.1.6.4.1.3OSStatenot-accessiblemandatory
dlOSRelDate
OBJECT-TYPE
Display the release date of the LuxnOS.
1.3.6.1.4.1.4253.1.6.4.1.4ReleaseDatenot-accessiblemandatory
dlUpdateOS
OBJECT-TYPE
Display and select Update LuxnOS Mode: toggle(1) to toggle between operating and backup LuxnOS, revert(2) to copy LuxnOS from the backup to the operating area. The action will be taken after setting UpdateOS .
1.3.6.1.4.1.4253.1.6.5UpdateOSModenot-accessiblemandatory
fadm
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.7
fadmBootPromVer
OBJECT-TYPE
The current version string of the OADM Boot PROM code
1.3.6.1.4.1.4253.1.7.1VersionStringnot-accessiblemandatory
fadmROMSize
OBJECT-TYPE
Total Size of the ROM in Kilobyes
1.3.6.1.4.1.4253.1.7.2INTEGER (1..1024)not-accessiblemandatory
fadmNumSubDiv
OBJECT-TYPE
Number of the subdivisions of the ROM.
1.3.6.1.4.1.4253.1.7.3INTEGER (1..20)not-accessiblemandatory
fadmSubDivTable
OBJECT-TYPE
This table represents the number of sub divisions and the size of each subdivision in ROM memory
1.3.6.1.4.1.4253.1.7.4not-accessiblemandatory
fadmSubDivEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.7.4.1not-accessiblemandatory
fadmSubDivIndex
OBJECT-TYPE
Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
1.3.6.1.4.1.4253.1.7.4.1.1INTEGER (1..20)not-accessiblemandatory
fadmSubDivDescr
OBJECT-TYPE
Display Name of each Sub Division in ROM
1.3.6.1.4.1.4253.1.7.4.1.2DisplayString (SIZE(0..20))not-accessiblemandatory
fadmSubDivSize
OBJECT-TYPE
Size of each sub division in ROM in kilobytes
1.3.6.1.4.1.4253.1.7.4.1.3INTEGER (1..1024)not-accessiblemandatory
fadmSubDivOffset
OBJECT-TYPE
Starting address of each sub division in the ROM in HEX notation.
1.3.6.1.4.1.4253.1.7.4.1.4OCTET STRING (SIZE(0..8))not-accessiblemandatory
fadmNumber
OBJECT-TYPE
Number of FADM rows in the following table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.7.5INTEGERread-onlymandatory
fadmTable
OBJECT-TYPE
This table represents the information for each OADM module
1.3.6.1.4.1.4253.1.7.6not-accessiblemandatory
fadmEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.7.6.1not-accessiblemandatory
fadmCardLocation
OBJECT-TYPE
Location of the FADM Module.
1.3.6.1.4.1.4253.1.7.6.1.1CardLocationread-onlymandatory
fadmCardShelf
OBJECT-TYPE
The shelf of the Module is in. Valid values are: 1, 2 or 3 depending on the chassis type.
1.3.6.1.4.1.4253.1.7.6.1.2CardShelfread-onlymandatory
fadmCardSlot
OBJECT-TYPE
The slot within the shelf the module is in. The range of valid values range from 1 through 21 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.7.6.1.3SlotInputread-writemandatory
fadmMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the FADM card
1.3.6.1.4.1.4253.1.7.6.1.4DateAndTimenot-accessiblemandatory
fadmSerialNum
OBJECT-TYPE
Serial # of the FADM card.
1.3.6.1.4.1.4253.1.7.6.1.5SerialStringread-onlymandatory
fadmModelType
OBJECT-TYPE
Model type of the FADM
1.3.6.1.4.1.4253.1.7.6.1.6CardTyperead-onlymandatory
fadmName
OBJECT-TYPE
Display (Network) name of the FADM Card
1.3.6.1.4.1.4253.1.7.6.1.7CardNameread-writemandatory
fadmFWVersionID
OBJECT-TYPE
The current version string of the FADM FW code
1.3.6.1.4.1.4253.1.7.6.1.8VersionStringread-onlymandatory
fadmSetState
OBJECT-TYPE
Instruct the fadm to do a warmboot. A get on this will always return an other.
1.3.6.1.4.1.4253.1.7.6.1.9RebootTyperead-writemandatory
fadmNumPorts
OBJECT-TYPE
Total port numbers of FADM module.
1.3.6.1.4.1.4253.1.7.6.1.10INTEGERread-onlymandatory
fadmUpgradeFlag
OBJECT-TYPE
The FADM module's status is upgradeable or not.
1.3.6.1.4.1.4253.1.7.6.1.11INTEGER {upgradeable(1), notUpgradeable(2)}read-onlymandatory
fadmModelNum
OBJECT-TYPE
Model # of the FADM card. Up to 15 characters
1.3.6.1.4.1.4253.1.7.6.1.12DisplayStringread-onlymandatory
fadmITUNumber1
OBJECT-TYPE
Port 1's ITU wavelength.
1.3.6.1.4.1.4253.1.7.6.1.13INTEGERread-onlymandatory
fadmITUNumber2
OBJECT-TYPE
1.3.6.1.4.1.4253.1.7.6.1.14INTEGERread-onlymandatory
fadmInsertionLoss1
OBJECT-TYPE
Port 1's insertion loss in dB.
1.3.6.1.4.1.4253.1.7.6.1.15DisplayStringread-onlymandatory
fadmInsertionLoss2
OBJECT-TYPE
1.3.6.1.4.1.4253.1.7.6.1.16DisplayStringnot-accessiblemandatory
fadmExpressLoss
OBJECT-TYPE
Internal express port's insertion loss in dB.
1.3.6.1.4.1.4253.1.7.6.1.17DisplayStringread-onlymandatory
fadmHWName
OBJECT-TYPE
Display Hardware name of the FADM Card.
1.3.6.1.4.1.4253.1.7.6.1.18CardNameread-onlymandatory
fadmPathID
OBJECT-TYPE
Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
1.3.6.1.4.1.4253.1.7.6.1.19PathIdNameread-writemandatory
fadmAdminState
OBJECT-TYPE
Administrative control over that fadm card. Default value is enable. When disabled, no alarms/events gets generated.
1.3.6.1.4.1.4253.1.7.6.1.20INTEGER {disable(1), enable(2), na(3)}read-writemandatory
fadmCleiNum
OBJECT-TYPE
CLEI number of the fadm Card.
1.3.6.1.4.1.4253.1.7.6.1.21DisplayStringread-onlymandatory
fadmBand
OBJECT-TYPE
Optical band supported by the module. Valid only for BP-5 and BP-10 modules.
1.3.6.1.4.1.4253.1.7.6.1.22DisplayStringread-onlymandatory
fadmChannelsPerBand
OBJECT-TYPE
Number of channels per optical band supported by the module. Only valid for BP-5 and BP-10module.
1.3.6.1.4.1.4253.1.7.6.1.23INTEGERread-onlymandatory
fadmStartItu
OBJECT-TYPE
First ITU channel supported by the module. Valid only for BP-5 and BP-10 modules.
1.3.6.1.4.1.4253.1.7.6.1.24INTEGERread-onlymandatory
fadmEndItu
OBJECT-TYPE
Last ITU channel supported by the module. Valid only for BP-5 and BP-10 modules.
1.3.6.1.4.1.4253.1.7.6.1.25INTEGERread-onlymandatory
fadmPortTable
OBJECT-TYPE
This table represents the physical connection for each FADM card's port.
1.3.6.1.4.1.4253.1.7.7not-accessiblemandatory
fadmPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.7.7.1not-accessiblemandatory
fadmPortCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.7.7.1.1CardShelfread-onlymandatory
fadmPortCardSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.1.7.7.1.2SlotInputread-onlymandatory
fadmPortType
OBJECT-TYPE
Type of the FADM port. The order is CLI compatible. For FADM model type, the ports are listed on the left column
1.3.6.1.4.1.4253.1.7.7.1.3INTEGER {connATx-AToD(1), connARx-EXP(2), localTx-Local(3), localRx-Rx(4), connBTx(5), connBRx(6)}read-onlymandatory
fadmConnLocation
OBJECT-TYPE
The chassis's location of the card conn to.
1.3.6.1.4.1.4253.1.7.7.1.4CardLocationread-writemandatory
fadmConnIpAddress
OBJECT-TYPE
IpAddress of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the IP address of the node
1.3.6.1.4.1.4253.1.7.7.1.5IpAddressread-writemandatory
fadmConnChassisID
OBJECT-TYPE
Chassis ID of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the chassis Id of the local node
1.3.6.1.4.1.4253.1.7.7.1.6DisplayString (SIZE(0..16))read-writemandatory
fadmConnSystemName
OBJECT-TYPE
System Name of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the sysetem name of the local node.
1.3.6.1.4.1.4253.1.7.7.1.7DisplayString (SIZE(0..32))read-writemandatory
fadmConnCardType
OBJECT-TYPE
Module type connected to fadm port.
1.3.6.1.4.1.4253.1.7.7.1.8CardTyperead-writemandatory
fadmConnPort
OBJECT-TYPE
Conn port for FADM's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx.
1.3.6.1.4.1.4253.1.7.7.1.9INTEGERread-writemandatory
fadmConnShelf
OBJECT-TYPE
The shelf the card conn to. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.7.7.1.10ShelfInputread-writemandatory
fadmConnSlot
OBJECT-TYPE
The slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0.
1.3.6.1.4.1.4253.1.7.7.1.11SlotInputread-writemandatory
oppm
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.8
oppmBootPromVer
OBJECT-TYPE
The current version string of the oppm Boot PROM code
1.3.6.1.4.1.4253.1.8.1VersionStringnot-accessiblemandatory
oppmROMSize
OBJECT-TYPE
Total Size of the ROM in Kilobyes
1.3.6.1.4.1.4253.1.8.2INTEGER (0..1024)not-accessiblemandatory
oppmNumSubDiv
OBJECT-TYPE
Number of the subdivisions of the ROM.
1.3.6.1.4.1.4253.1.8.3INTEGER (0..20)not-accessiblemandatory
oppmSubDivTable
OBJECT-TYPE
This table represents the number of sub divisions and the size of each subdivision in ROM memory
1.3.6.1.4.1.4253.1.8.4not-accessiblemandatory
oppmSubDivEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.8.4.1not-accessiblemandatory
oppmSubDivIndex
OBJECT-TYPE
Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
1.3.6.1.4.1.4253.1.8.4.1.1INTEGER (0..20)not-accessiblemandatory
oppmSubDivDescr
OBJECT-TYPE
Display Name of each Sub Division in ROM
1.3.6.1.4.1.4253.1.8.4.1.2DisplayString (SIZE(0..20))not-accessiblemandatory
oppmSubDivSize
OBJECT-TYPE
Size of each sub division in ROM in kilobytes
1.3.6.1.4.1.4253.1.8.4.1.3INTEGER (0..1024)not-accessiblemandatory
oppmSubDivOffset
OBJECT-TYPE
Starting address of each sub division in the ROM in HEX notation.
1.3.6.1.4.1.4253.1.8.4.1.4OCTET STRING (SIZE(0..8))not-accessiblemandatory
oppmNumber
OBJECT-TYPE
Number of OPPM rows in the following table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.8.5INTEGERnot-accessiblemandatory
oppmTable
OBJECT-TYPE
This table represents the information for each OPPM card
1.3.6.1.4.1.4253.1.8.6not-accessiblemandatory
oppmEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.8.6.1not-accessiblemandatory
oppmCardLocation
OBJECT-TYPE
Location of the OPPM card. Valid values are: Local in the same chassis, or remote to this chassis
1.3.6.1.4.1.4253.1.8.6.1.1CardLocationnot-accessiblemandatory
oppmCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2
1.3.6.1.4.1.4253.1.8.6.1.2CardShelfnot-accessiblemandatory
oppmCardSlot
OBJECT-TYPE
The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.8.6.1.3SlotInputnot-accessiblemandatory
oppmModelNum
OBJECT-TYPE
Oppm's model number.
1.3.6.1.4.1.4253.1.8.6.1.4DisplayStringnot-accessiblemandatory
oppmMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the OPPM card
1.3.6.1.4.1.4253.1.8.6.1.5DateAndTimenot-accessiblemandatory
oppmSerialNum
OBJECT-TYPE
Serial # of the OPPM card.
1.3.6.1.4.1.4253.1.8.6.1.6SerialStringnot-accessiblemandatory
oppmModelType
OBJECT-TYPE
Model type of the OPPM
1.3.6.1.4.1.4253.1.8.6.1.7CardTypenot-accessiblemandatory
oppmName
OBJECT-TYPE
Display (Network) name of the OPPM Card
1.3.6.1.4.1.4253.1.8.6.1.8CardNamenot-accessiblemandatory
oppmFWVersionID
OBJECT-TYPE
The current version string of the OPPM FW code
1.3.6.1.4.1.4253.1.8.6.1.9VersionStringnot-accessiblemandatory
oppmSetState
OBJECT-TYPE
Instruct the oppm to do a warmboot. A get on this will always return an other.
1.3.6.1.4.1.4253.1.8.6.1.10RebootTypenot-accessiblemandatory
oppmTxInsertLoss
OBJECT-TYPE
Transmit insertion loss.
1.3.6.1.4.1.4253.1.8.6.1.12DisplayStringnot-accessiblemandatory
oppmRxInsertLoss
OBJECT-TYPE
Receive insertion loss.
1.3.6.1.4.1.4253.1.8.6.1.13DisplayStringnot-accessiblemandatory
oppmUpgradeFlag
OBJECT-TYPE
The oppm card's status is upgradable or not.
1.3.6.1.4.1.4253.1.8.6.1.14INTEGER {upgradable(1), notUpgradable(2)}not-accessiblemandatory
oppmSwitch
OBJECT-TYPE
instruct the OPPM to take on an action, such as: switch to link A or link B A get would alway return other(1).
1.3.6.1.4.1.4253.1.8.6.1.15INTEGER {other(1), switchToLinkA(2), switchToLinkB(3), toggle(4), enableAutoSwitch(6)}not-accessiblemandatory
oppmMarginForSwitch
OBJECT-TYPE
Configurable switching margin in dB for protection switch to occur.
1.3.6.1.4.1.4253.1.8.6.1.16INTEGER (5..15)not-accessiblemandatory
oppmHighAlarmMargin
OBJECT-TYPE
High alarm margin for input signal strength displayed in dB unit
1.3.6.1.4.1.4253.1.8.6.1.17INTEGERnot-accessiblemandatory
oppmConfigCommit
OBJECT-TYPE
This allows the current module configuration, such as oppmMarginForSwitch, to be stored in permanent storage.
1.3.6.1.4.1.4253.1.8.6.1.18INTEGER {other(1), save(2)}not-accessiblemandatory
oppmHWName
OBJECT-TYPE
Display Hardware name of the OPPM Card.
1.3.6.1.4.1.4253.1.8.6.1.19CardNamenot-accessiblemandatory
oppmLinkAPathID
OBJECT-TYPE
Oppmm LinkA Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
1.3.6.1.4.1.4253.1.8.6.1.20PathIdNamenot-accessiblemandatory
oppmLinkBPathID
OBJECT-TYPE
Oppm LinkB Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
1.3.6.1.4.1.4253.1.8.6.1.21PathIdNamenot-accessiblemandatory
oppmAdminState
OBJECT-TYPE
Administrative control over that oppm card. Default value is enable. When disabled, no alarms/events gets generated.
1.3.6.1.4.1.4253.1.8.6.1.22INTEGER {disable(1), enable(2), na(3)}not-accessiblemandatory
oppmCleiNum
OBJECT-TYPE
CLEI number of the oppm Card.
1.3.6.1.4.1.4253.1.8.6.1.23DisplayStringnot-accessiblemandatory
oppmSwitchState
OBJECT-TYPE
The switching state. Switching state may be either auto or forced. The auto state means automatic switching is enabled. Forced state means swithcing is disabled and has been forced to the current active link.
1.3.6.1.4.1.4253.1.8.6.1.24INTEGER {auto(1), forced(2)}not-accessiblemandatory
oppmPortTable
OBJECT-TYPE
This table represents the physical connection for each OPPM card's port.
1.3.6.1.4.1.4253.1.8.7not-accessiblemandatory
oppmPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.8.7.1not-accessiblemandatory
oppmPortCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.8.7.1.1CardShelfnot-accessiblemandatory
oppmPortCardSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.1.8.7.1.2SlotInputnot-accessiblemandatory
oppmPortType
OBJECT-TYPE
Type of the OPPM's port.
1.3.6.1.4.1.4253.1.8.7.1.3INTEGER {linkATx(1), linkARx(2), linkBTx(3), linkBRx(4), localTx(5), localRx(6)}read-writemandatory
oppmConnLocation
OBJECT-TYPE
The chassis's location of the card conn to.
1.3.6.1.4.1.4253.1.8.7.1.4CardLocationnot-accessiblemandatory
oppmConnIpAddress
OBJECT-TYPE
IpAddress of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the IP address of the node
1.3.6.1.4.1.4253.1.8.7.1.5IpAddressnot-accessiblemandatory
oppmConnChassisID
OBJECT-TYPE
Chassis ID of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the chassis Id of the local node
1.3.6.1.4.1.4253.1.8.7.1.6DisplayString (SIZE(0..16))not-accessiblemandatory
oppmConnSystemName
OBJECT-TYPE
System Name of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the sysetem name of the local node.
1.3.6.1.4.1.4253.1.8.7.1.7DisplayString (SIZE(0..32))not-accessiblemandatory
oppmConnCardType
OBJECT-TYPE
Module type connected to oppm port.
1.3.6.1.4.1.4253.1.8.7.1.8CardTypenot-accessiblemandatory
oppmConnPort
OBJECT-TYPE
Conn port for OPPM's port. Possible values based on card types that can connect to OPPM are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx.
1.3.6.1.4.1.4253.1.8.7.1.9INTEGERnot-accessiblemandatory
oppmConnShelf
OBJECT-TYPE
The shelf the card conn to. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.8.7.1.10ShelfInputnot-accessiblemandatory
oppmConnSlot
OBJECT-TYPE
The slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0.
1.3.6.1.4.1.4253.1.8.7.1.11SlotInputnot-accessiblemandatory
mcm
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.9
mcmBootPromVer
OBJECT-TYPE
The current version string of the mcmt1/mcme1 Boot PROM code
1.3.6.1.4.1.4253.1.9.1VersionStringnot-accessiblemandatory
mcmROMSize
OBJECT-TYPE
Total Size of the ROM in Kilobyes
1.3.6.1.4.1.4253.1.9.2INTEGER (0..1024)not-accessiblemandatory
mcmNumSubDiv
OBJECT-TYPE
Number of the subdivisions of the ROM.
1.3.6.1.4.1.4253.1.9.3INTEGER (0..20)not-accessiblemandatory
mcmSubDivTable
OBJECT-TYPE
This table represents the number of sub divisions and the size of each subdivision in ROM memory
1.3.6.1.4.1.4253.1.9.4not-accessiblemandatory
mcmSubDivEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.9.4.1not-accessiblemandatory
mcmSubDivIndex
OBJECT-TYPE
Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
1.3.6.1.4.1.4253.1.9.4.1.1INTEGER (0..20)not-accessiblemandatory
mcmSubDivDescr
OBJECT-TYPE
Display Name of each Sub Division in ROM
1.3.6.1.4.1.4253.1.9.4.1.2DisplayString (SIZE(0..20))not-accessiblemandatory
mcmSubDivSize
OBJECT-TYPE
Size of each sub division in ROM in kilobytes
1.3.6.1.4.1.4253.1.9.4.1.3INTEGER (0..1024)not-accessiblemandatory
mcmSubDivOffset
OBJECT-TYPE
Starting address of each sub division in the ROM in HEX notation.
1.3.6.1.4.1.4253.1.9.4.1.4OCTET STRING (SIZE(0..8))not-accessiblemandatory
mcmNumber
OBJECT-TYPE
Number of ADM rows in the following table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.9.5INTEGERread-onlymandatory
mcmTable
OBJECT-TYPE
This table represents the information for each mcmt1/mcme1 module
1.3.6.1.4.1.4253.1.9.6not-accessiblemandatory
mcmEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.9.6.1not-accessiblemandatory
mcmCardLocation
OBJECT-TYPE
Location of the mcmt1/mcme1 Module.
1.3.6.1.4.1.4253.1.9.6.1.1CardLocationread-onlymandatory
mcmCardShelf
OBJECT-TYPE
The shelf of the mcmt1/mcme1 is in. Valid values are: 1..2
1.3.6.1.4.1.4253.1.9.6.1.2CardShelfread-onlymandatory
mcmCardSlot
OBJECT-TYPE
The slot within the shelf the module is in. The range of valid values range from 1 through 21 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.9.6.1.3SlotInputread-writemandatory
mcmMfgDate
OBJECT-TYPE
Date and Time of calibration of the mcmt1/mcme1 card
1.3.6.1.4.1.4253.1.9.6.1.4DateAndTimeread-onlymandatory
mcmSerialNum
OBJECT-TYPE
Serial # of the mcmt1/mcme1 card.
1.3.6.1.4.1.4253.1.9.6.1.5SerialStringread-onlymandatory
mcmModelType
OBJECT-TYPE
Model type of the mcmt1/mcme1
1.3.6.1.4.1.4253.1.9.6.1.6CardTyperead-onlymandatory
mcmName
OBJECT-TYPE
Display (Network) name of the MCMT1/MCME1 Module
1.3.6.1.4.1.4253.1.9.6.1.7CardNameread-writemandatory
mcmFWVersionID
OBJECT-TYPE
The current version string of the MCMT1/MCME1 FW code
1.3.6.1.4.1.4253.1.9.6.1.8VersionStringread-onlymandatory
mcmAdminState
OBJECT-TYPE
Administrative control over that mcmt1/mcme1 card. Default value is enable. When disabled, no alarms/events gets generated.
1.3.6.1.4.1.4253.1.9.6.1.9INTEGER {disable(1), enable(2), na(3)}read-writemandatory
mcmLaserTemperature
OBJECT-TYPE
Temperature of the Laser. Not yet supported
1.3.6.1.4.1.4253.1.9.6.1.10INTEGERnot-accessiblemandatory
mcmBandwidth
OBJECT-TYPE
mcmt1/mcme1 module's line rate.
1.3.6.1.4.1.4253.1.9.6.1.11INTEGER {other(1), oc3(2), oc12(3), oc48(4), gbEthernet(5), fibreChannel(6)}not-accessiblemandatory
mcmSetState
OBJECT-TYPE
Instruct the mcmt1/mcme1 card to do either a reset or loopback. A get on this will always return an other.
1.3.6.1.4.1.4253.1.9.6.1.12INTEGER {other(1), resetWithCurrentConfiguration(2), resetWithFactoryDefault(3), nearEndCardLoopback(4), networkCardLoopback(5), nearEndPort1Loopback(6), nearEndPort2Loopback(7), nearEndPort3Loopback(8), nearEndPort4Loopback(9), networkPort1Loopback(10), networkPort2Loopback(11), networkPort3Loopback(12), networkPort4Loopback(13), disableLoopback(14)}read-writemandatory
mcmNumPorts
OBJECT-TYPE
Total port numbers of MCMT1/MCME1 module.
1.3.6.1.4.1.4253.1.9.6.1.13INTEGERread-onlymandatory
mcmUpgradeFlag
OBJECT-TYPE
The MCMT1/MCME1 module's status is upgradable or not.
1.3.6.1.4.1.4253.1.9.6.1.14INTEGER {upgradable(1), notUpgradable(2)}read-onlymandatory
mcmEthernetStatus
OBJECT-TYPE
The MCMT1/MCME1 module's Ethernet status is down or up.
1.3.6.1.4.1.4253.1.9.6.1.15INTEGER {disabled(1), enabled(2)}read-writemandatory
mcmTimingPort
OBJECT-TYPE
The MCMT1/MCME1 module's port clock src
1.3.6.1.4.1.4253.1.9.6.1.16INTEGER {internal(1), link(2), t1Port1(3), t1Port2(4), t1Port3(5), t1Port4(6)}read-onlymandatory
mcmModelNum
OBJECT-TYPE
The mcmt1/mcme1 port's model number
1.3.6.1.4.1.4253.1.9.6.1.17DisplayStringread-onlymandatory
mcmMfgBiasCurrent
OBJECT-TYPE
Bias current for the optical laser. This is the preset manufacturing value
1.3.6.1.4.1.4253.1.9.6.1.18INTEGERread-onlymandatory
mcmMfgModulation
OBJECT-TYPE
The frequency modulation for the optical laser. This value is the preset manufacturing value.
1.3.6.1.4.1.4253.1.9.6.1.19INTEGERread-onlymandatory
mcmMfgApc
OBJECT-TYPE
The APC value. This value is the preset manufacturing value
1.3.6.1.4.1.4253.1.9.6.1.20INTEGERread-onlymandatory
mcmMfgIwmModulation
OBJECT-TYPE
The frequency modulation for the IWM channel. This value is the preset manufacturing value
1.3.6.1.4.1.4253.1.9.6.1.21INTEGERread-onlymandatory
mcmconnMuxShelf
OBJECT-TYPE
The connected mux shelf.
1.3.6.1.4.1.4253.1.9.6.1.22ShelfInputread-onlymandatory
mcmconnMuxSlot
OBJECT-TYPE
The connected mux slot.
1.3.6.1.4.1.4253.1.9.6.1.23SlotInputread-onlymandatory
mcmconnMuxPort
OBJECT-TYPE
The connected mux port.
1.3.6.1.4.1.4253.1.9.6.1.24INTEGERread-onlymandatory
mcmconnDemuxShelf
OBJECT-TYPE
The connected demux shelf.
1.3.6.1.4.1.4253.1.9.6.1.25ShelfInputread-onlymandatory
mcmconnDemuxSlot
OBJECT-TYPE
The connected demux slot.
1.3.6.1.4.1.4253.1.9.6.1.26SlotInputread-onlymandatory
mcmconnDemuxPort
OBJECT-TYPE
The connected demux port.
1.3.6.1.4.1.4253.1.9.6.1.27INTEGERread-onlymandatory
mcmTimingPriority
OBJECT-TYPE
The clock source priority in descending order in the format of a,b,c,d,e,f in which a through f should be replaced with 1 through 6 which has the same meaning as the options of mcmTimingPort and are repeated as follows: 0 - unknown 1 - internal 2 - link 3 - t1Port1 4 - t1Port2 5 - t1Port3 6 - t1Port4 For example, '2,5,4,6,3,1' will set the priority of the clock source with link first, followed by t1Port3, followed by t1Port2, followed by t1Port4, followed by t1Port1, followed by internal.
1.3.6.1.4.1.4253.1.9.6.1.28DisplayString (SIZE(0..12))read-writemandatory
mcmLinkName
OBJECT-TYPE
User configurable Link name for the connection between the local and remote MCM/MCME1 Modules
1.3.6.1.4.1.4253.1.9.6.1.29LinkNameread-writemandatory
mcmEthernetMode
OBJECT-TYPE
This allows the ethernet mode configured as auto detect, forced 10M, or forced 100M.
1.3.6.1.4.1.4253.1.9.6.1.30INTEGER {auto(1), forced10M(2), forced100M(3)}read-writemandatory
mcmHWName
OBJECT-TYPE
Display Hardware name of the MCMT1/MCME1 Card.
1.3.6.1.4.1.4253.1.9.6.1.31CardNameread-onlymandatory
mcmLinkWaveLength
OBJECT-TYPE
Link Wavelength of the MCMT1/MCME1 card
1.3.6.1.4.1.4253.1.9.6.1.32DisplayString (SIZE(0..15))read-onlymandatory
mcmFpgaVersionID
OBJECT-TYPE
The current version string of the MCMT1/MCME1 FPGA.
1.3.6.1.4.1.4253.1.9.6.1.33VersionStringread-onlymandatory
mcmPathID
OBJECT-TYPE
Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
1.3.6.1.4.1.4253.1.9.6.1.34PathIdNameread-writemandatory
mcmCleiNum
OBJECT-TYPE
CLEI number of the mcmt1/mcme1 Card.
1.3.6.1.4.1.4253.1.9.6.1.35DisplayStringread-onlymandatory
mcmItuNum
OBJECT-TYPE
ITU number of the mcmt1/mcme1 Card.
1.3.6.1.4.1.4253.1.9.6.1.36DisplayStringread-onlymandatory
mcmPortNumber
OBJECT-TYPE
Number of MCMT1/MCME1 rows in the following table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.9.7INTEGERread-onlymandatory
mcmPortTable
OBJECT-TYPE
This table represents the information for each MCMT1/MCME1 module's port.
1.3.6.1.4.1.4253.1.9.8not-accessiblemandatory
mcmPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.9.8.1not-accessiblemandatory
mcmPortCardLocation
OBJECT-TYPE
Location of the MCMT1/MCME1 port. Valid values are: Local in the same chassis, or remote to this chassis
1.3.6.1.4.1.4253.1.9.8.1.1CardLocationread-onlymandatory
mcmPortCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1..2.
1.3.6.1.4.1.4253.1.9.8.1.2CardShelfread-onlymandatory
mcmPortCardSlot
OBJECT-TYPE
The slot within the shelf the Module is in. Valid values are: 1 to 17
1.3.6.1.4.1.4253.1.9.8.1.3SlotInputread-onlymandatory
mcmPortIndex
OBJECT-TYPE
Port's index.
1.3.6.1.4.1.4253.1.9.8.1.4INTEGERread-onlymandatory
mcmPortConnection
OBJECT-TYPE
Port's connection status.
1.3.6.1.4.1.4253.1.9.8.1.5INTEGER {disabled(1), enabled(2)}read-writemandatory
mcmPortFraming
OBJECT-TYPE
Type of framing. esf(1) and d4(2) are for mcmt1. crc4(3) is for mcme1. For mcme1, this release of hardware and software only supports fixed configuration, CRC4, hence, operation of setting will return an error.
1.3.6.1.4.1.4253.1.9.8.1.6INTEGER {esf(1), d4(2), crc4(3)}read-writemandatory
mcmPortLineCoding
OBJECT-TYPE
Type of line coding. b8zs(1) and ami(2) are for mcmt1. hdb3(3) is for mcme1. For mcme1, this release of hardware and software only supports fixed configuration, HDB3, hence, operation of setting will return an error.
1.3.6.1.4.1.4253.1.9.8.1.7INTEGER {b8zs(1), ami(2), hdb3(3)}read-writemandatory
mcmPortLineEqualizer
OBJECT-TYPE
The Line equilizer. ft0to133(1), ft133to266(2), ft266to399(3), ft399to533(4), and ft533to655(5) are for mcmt1. minus43dB(6) is for mcme1. For mcme1, this release of hardware and software only supports fixed configuration, -43dB, hence, operation of setting will return an error.
1.3.6.1.4.1.4253.1.9.8.1.8INTEGER {ft0to133(1), ft133to266(2), ft266to399(3), ft399to533(4), ft533to655(5), minus43dB(6)}read-writemandatory
mcmPortImpedance
OBJECT-TYPE
Port impedance. ohms-100(1) is for mcmt1. ohms-75(2) and ohms-120(3) are for mcme1. For mcme1, this release of hardware and software only supports fixed configuration, 75 ohm, hence, operation of setting will return an error.
1.3.6.1.4.1.4253.1.9.8.1.9INTEGER {ohms-100(1), ohms-75(2), ohms-120(3)}read-onlymandatory
fn
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.10
fnNumber
OBJECT-TYPE
Number of fn rows in the following table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.10.1INTEGERnot-accessiblemandatory
fnTable
OBJECT-TYPE
This table represents the information for each fn.
1.3.6.1.4.1.4253.1.10.2not-accessiblemandatory
fnEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.10.2.1not-accessiblemandatory
fnID
OBJECT-TYPE
The slot ID the fn is in. Valid values are: 1 to 4
1.3.6.1.4.1.4253.1.10.2.1.1INTEGER (1..4)not-accessiblemandatory
fnMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the fn
1.3.6.1.4.1.4253.1.10.2.1.2DateAndTimenot-accessiblemandatory
fnSerialNum
OBJECT-TYPE
Serial # of the fn. Not Supported Yet.
1.3.6.1.4.1.4253.1.10.2.1.3SerialStringnot-accessiblemandatory
fnModelType
OBJECT-TYPE
Model type of the fn. Up to 10 characters. Not Supported Yet.
1.3.6.1.4.1.4253.1.10.2.1.4ModelStringnot-accessiblemandatory
csim
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.11
csimSysMode
OBJECT-TYPE
The ColorSim Mode of the Chassis. The value Enable means that the ColorSim feature is enabled for all the interface cards. An action element, returns other on a get request.
1.3.6.1.4.1.4253.1.11.1INTEGER {enable(1), disable(2), other(3)}read-writemandatory
csimTable
OBJECT-TYPE
Each entry in this table represents the information for each colorsim card.
1.3.6.1.4.1.4253.1.11.2not-accessiblemandatory
csimEntry
OBJECT-TYPE
Specifies the index for each row in the table below.
1.3.6.1.4.1.4253.1.11.2.1not-accessiblemandatory
csimLocation
OBJECT-TYPE
Location of the card. Valid values are: Local in the same chassis, or remote to this chassis.
1.3.6.1.4.1.4253.1.11.2.1.1CardLocationread-onlymandatory
csimShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.1.11.2.1.2CardShelfread-onlymandatory
csimSlot
OBJECT-TYPE
This card occupies two slots currently.
1.3.6.1.4.1.4253.1.11.2.1.3SlotInputread-onlymandatory
csimMode
OBJECT-TYPE
The Mode of ColorSIM for this entry. The Modes are Enable or Disable.
1.3.6.1.4.1.4253.1.11.2.1.4INTEGER {enable(1), disable(2)}read-writemandatory
csimDCMode
OBJECT-TYPE
The Data Collection Mode of ColorSIM.
1.3.6.1.4.1.4253.1.11.2.1.5INTEGER {standard(1), continuous(2)}read-writemandatory
csimGatingIntvl
OBJECT-TYPE
The Gating Interval in seconds in which the incoming data stream is being monitored for errors.
1.3.6.1.4.1.4253.1.11.2.1.6INTEGER (1..65535)read-writemandatory
csimUpdtIntvl
OBJECT-TYPE
Number of gating intervals to be processed before the data is logged for reporting purposes.
1.3.6.1.4.1.4253.1.11.2.1.7INTEGER (1..65535)read-writemandatory
csimSEIThreshold
OBJECT-TYPE
The SEI Threshold of ColorSIM specifies the maximum number of errored bits that may have occurred during a single gating interval before the interval is considered Severely Errorred. The Threshold values are in the form of x.ye-z.
1.3.6.1.4.1.4253.1.11.2.1.8DisplayStringread-writemandatory
rpsm
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.12
rpsmBootPromVer
OBJECT-TYPE
The current version string of the rpsm Boot PROM code
1.3.6.1.4.1.4253.1.12.1VersionStringnot-accessiblemandatory
rpsmROMSize
OBJECT-TYPE
Total Size of the ROM in Kilobyes
1.3.6.1.4.1.4253.1.12.2INTEGER (0..1024)not-accessiblemandatory
rpsmNumSubDiv
OBJECT-TYPE
Number of the subdivisions of the ROM.
1.3.6.1.4.1.4253.1.12.3INTEGER (0..20)not-accessiblemandatory
rpsmSubDivTable
OBJECT-TYPE
This table represents the number of sub divisions and the size of each subdivision in ROM memory
1.3.6.1.4.1.4253.1.12.4not-accessiblemandatory
rpsmSubDivEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.12.4.1not-accessiblemandatory
rpsmSubDivIndex
OBJECT-TYPE
Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
1.3.6.1.4.1.4253.1.12.4.1.1INTEGER (0..20)not-accessiblemandatory
rpsmSubDivDescr
OBJECT-TYPE
Display Name of each Sub Division in ROM
1.3.6.1.4.1.4253.1.12.4.1.2DisplayString (SIZE(0..20))not-accessiblemandatory
rpsmSubDivSize
OBJECT-TYPE
Size of each sub division in ROM in kilobytes
1.3.6.1.4.1.4253.1.12.4.1.3INTEGER (0..1024)not-accessiblemandatory
rpsmSubDivOffset
OBJECT-TYPE
Starting address of each sub division in the ROM in HEX notation.
1.3.6.1.4.1.4253.1.12.4.1.4OCTET STRING (SIZE(0..8))not-accessiblemandatory
rpsmNumber
OBJECT-TYPE
Number of RPSM rows in the following table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.12.5INTEGERnot-accessiblemandatory
rpsmTable
OBJECT-TYPE
This table represents the information for each RPSM card
1.3.6.1.4.1.4253.1.12.6not-accessiblemandatory
rpsmEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.12.6.1not-accessiblemandatory
rpsmCardLocation
OBJECT-TYPE
Location of the RPSM card. Valid values are: Local in the same chassis, or remote to this chassis.
1.3.6.1.4.1.4253.1.12.6.1.1CardLocationnot-accessiblemandatory
rpsmCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.12.6.1.2CardShelfnot-accessiblemandatory
rpsmCardSlot
OBJECT-TYPE
The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.12.6.1.3SlotInputnot-accessiblemandatory
rpsmModelNum
OBJECT-TYPE
RPSM's model number.
1.3.6.1.4.1.4253.1.12.6.1.4DisplayStringnot-accessiblemandatory
rpsmOpticsMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the optics on the RPSM card.
1.3.6.1.4.1.4253.1.12.6.1.5DateAndTimenot-accessiblemandatory
rpsmSerialNum
OBJECT-TYPE
Serial # of the RPSM card.
1.3.6.1.4.1.4253.1.12.6.1.6SerialStringnot-accessiblemandatory
rpsmModelType
OBJECT-TYPE
Model type of the RPSM.
1.3.6.1.4.1.4253.1.12.6.1.7INTEGER {rpsm(17)}not-accessiblemandatory
rpsmHWName
OBJECT-TYPE
Manufacturing Hardware name of the RPSM Card.
1.3.6.1.4.1.4253.1.12.6.1.8CardNamenot-accessiblemandatory
rpsmFWVersionID
OBJECT-TYPE
The current version string of the RPSM FW code
1.3.6.1.4.1.4253.1.12.6.1.9VersionStringnot-accessiblemandatory
rpsmCardName
OBJECT-TYPE
User configurable card name.
1.3.6.1.4.1.4253.1.12.6.1.10CardNamenot-accessiblemandatory
rpsmFWName
OBJECT-TYPE
RPSM's Firmware Name.
1.3.6.1.4.1.4253.1.12.6.1.11DisplayStringnot-accessiblemandatory
rpsmFWDate
OBJECT-TYPE
Date and Time of latest Firmware of the RPSM card.
1.3.6.1.4.1.4253.1.12.6.1.12DateAndTimenot-accessiblemandatory
rpsmHWVersionID
OBJECT-TYPE
The current version string of the RPSM HW code.
1.3.6.1.4.1.4253.1.12.6.1.13VersionStringnot-accessiblemandatory
rpsmHWDate
OBJECT-TYPE
Date and Time of Hardware of the RPSM card.
1.3.6.1.4.1.4253.1.12.6.1.14DateAndTimenot-accessiblemandatory
rpsmSetState
OBJECT-TYPE
Instruct the rpsm to do a warmboot. A get on this will always return an other.
1.3.6.1.4.1.4253.1.12.6.1.15RebootTypenot-accessiblemandatory
rpsmExpressLoss
OBJECT-TYPE
Insertion loss for the expressed channel through the RPSM module in dB.
1.3.6.1.4.1.4253.1.12.6.1.16DisplayStringnot-accessiblemandatory
rpsmMarginForSwitch
OBJECT-TYPE
Switching threshold in dB for protection switch to occur.
1.3.6.1.4.1.4253.1.12.6.1.17INTEGER (-40..0)not-accessiblemandatory
rpsmMinProtPowerForSwitch
OBJECT-TYPE
Minimum protection link's light power in dBm to allow protection switching to occur.
1.3.6.1.4.1.4253.1.12.6.1.18INTEGER (-40..0)not-accessiblemandatory
rpsmDeBounce
OBJECT-TYPE
Debounce in number of times to measure low light power before protection switch.
1.3.6.1.4.1.4253.1.12.6.1.19INTEGERnot-accessiblemandatory
rpsmBlackOutTime
OBJECT-TYPE
Black out time in unit of 0.1 second after protection switch to allow another protection switch to occur again.
1.3.6.1.4.1.4253.1.12.6.1.20INTEGERnot-accessiblemandatory
rpsmSwitch
OBJECT-TYPE
instruct the RPSM to take on an action, such as: switch to link A or link B. A get would alway return other(1).
1.3.6.1.4.1.4253.1.12.6.1.21INTEGER {other(1), switchToLinkA(2), switchToLinkB(3), toggle(4), enableAutoSwitch(6)}not-accessiblemandatory
rpsmAddDropLoss
OBJECT-TYPE
Insertion loss of the Add/Drop path through the RPSM module in dB.
1.3.6.1.4.1.4253.1.12.6.1.22DisplayStringnot-accessiblemandatory
rpsmPathID
OBJECT-TYPE
Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
1.3.6.1.4.1.4253.1.12.6.1.23PathIdNamenot-accessiblemandatory
rpsmAdminState
OBJECT-TYPE
Administrative control over that rpsm card. Default value is enable. When disabled, no alarms/events gets generated.
1.3.6.1.4.1.4253.1.12.6.1.24INTEGER {disable(1), enable(2), na(3)}not-accessiblemandatory
rpsmPortTable
OBJECT-TYPE
This table represents the physical connection for each RPSM card's port.
1.3.6.1.4.1.4253.1.12.7not-accessiblemandatory
rpsmPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.12.7.1not-accessiblemandatory
rpsmPortCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.12.7.1.1CardShelfnot-accessiblemandatory
rpsmPortCardSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.1.12.7.1.2SlotInputnot-accessiblemandatory
rpsmPortType
OBJECT-TYPE
Type of the RPSM's port. The order is CLI compatible.
1.3.6.1.4.1.4253.1.12.7.1.3INTEGER {linkEast(1), linkWest(2), in(3), out(4), aTOd(5), exp(6)}not-accessiblemandatory
rpsmConnCardType
OBJECT-TYPE
Type of connection. Valid values are ocmu(2), ocmItu(3), mux(4), demux(5), mcm(8), w4cd(10), w2cmd(13), w4cm(21), osam(20), fadm(6), oppm(7), fadmb(19), ocme(24), etc... A zero will be used for no connections.
1.3.6.1.4.1.4253.1.12.7.1.4INTEGER (0..30)not-accessiblemandatory
rpsmConnPort
OBJECT-TYPE
Conn port for RPSM's port.Possible values based on card types that can connect to RPSM are: OFCM/OFCD: 1/2/3/4= port index, 5=EXP, 6=OUT/IN W4CM/W4CD: 1=1510, 2=1530, 3=1550, 4=1570, 5=EXP, 6=IN/OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT OSAM: 1=IN, 2=OUT FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx FADMB: 1=A/D, 2=EXP, 3=Local, 4=Rx OCMU/OCMITU/MCM: 1=Link Tx, 2=Link Rx UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx
1.3.6.1.4.1.4253.1.12.7.1.5INTEGERnot-accessiblemandatory
rpsmConnShelf
OBJECT-TYPE
The shelf the card conn to. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.12.7.1.6ShelfInputnot-accessiblemandatory
rpsmConnSlot
OBJECT-TYPE
The slot within the shelf the card conn to.
1.3.6.1.4.1.4253.1.12.7.1.7SlotInputnot-accessiblemandatory
rsdm
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.13
rsdmBootPromVer
OBJECT-TYPE
The current version string of the rsdm Boot PROM code
1.3.6.1.4.1.4253.1.13.1VersionStringnot-accessiblemandatory
rsdmROMSize
OBJECT-TYPE
Total Size of the ROM in Kilobyes
1.3.6.1.4.1.4253.1.13.2INTEGER (0..1024)not-accessiblemandatory
rsdmNumSubDiv
OBJECT-TYPE
Number of the subdivisions of the ROM.
1.3.6.1.4.1.4253.1.13.3INTEGER (0..20)not-accessiblemandatory
rsdmSubDivTable
OBJECT-TYPE
This table represents the number of sub divisions and the size of each subdivision in ROM memory
1.3.6.1.4.1.4253.1.13.4not-accessiblemandatory
rsdmSubDivEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.13.4.1not-accessiblemandatory
rsdmSubDivIndex
OBJECT-TYPE
Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
1.3.6.1.4.1.4253.1.13.4.1.1INTEGER (0..20)not-accessiblemandatory
rsdmSubDivDescr
OBJECT-TYPE
Display Name of each Sub Division in ROM
1.3.6.1.4.1.4253.1.13.4.1.2DisplayString (SIZE(0..20))not-accessiblemandatory
rsdmSubDivSize
OBJECT-TYPE
Size of each sub division in ROM in kilobytes
1.3.6.1.4.1.4253.1.13.4.1.3INTEGER (0..1024)not-accessiblemandatory
rsdmSubDivOffset
OBJECT-TYPE
Starting address of each sub division in the ROM in HEX notation.
1.3.6.1.4.1.4253.1.13.4.1.4OCTET STRING (SIZE(0..8))not-accessiblemandatory
rsdmNumber
OBJECT-TYPE
Number of RSDM rows in the following table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.13.5INTEGERnot-accessiblemandatory
rsdmTable
OBJECT-TYPE
This table represents the information for each RSDM card
1.3.6.1.4.1.4253.1.13.6not-accessiblemandatory
rsdmEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.13.6.1not-accessiblemandatory
rsdmCardLocation
OBJECT-TYPE
Location of the RSDM card. Valid values are: Local in the same chassis, or remote to this chassis.
1.3.6.1.4.1.4253.1.13.6.1.1CardLocationnot-accessiblemandatory
rsdmCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2
1.3.6.1.4.1.4253.1.13.6.1.2CardShelfnot-accessiblemandatory
rsdmCardSlot
OBJECT-TYPE
The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.13.6.1.3SlotInputnot-accessiblemandatory
rsdmModelNum
OBJECT-TYPE
RSDM's model number.
1.3.6.1.4.1.4253.1.13.6.1.4DisplayStringnot-accessiblemandatory
rsdmOpticsMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the optics on the RSDM card.
1.3.6.1.4.1.4253.1.13.6.1.5DateAndTimenot-accessiblemandatory
rsdmSerialNum
OBJECT-TYPE
Serial # of the RSDM card.
1.3.6.1.4.1.4253.1.13.6.1.6SerialStringnot-accessiblemandatory
rsdmModelType
OBJECT-TYPE
Model type of the RSDM.
1.3.6.1.4.1.4253.1.13.6.1.7INTEGER {rsdm(16)}not-accessiblemandatory
rsdmHWName
OBJECT-TYPE
Display Hardware name of the RSDM Card.
1.3.6.1.4.1.4253.1.13.6.1.8CardNamenot-accessiblemandatory
rsdmCardName
OBJECT-TYPE
User configurable name of the RSDM Card.
1.3.6.1.4.1.4253.1.13.6.1.9CardNamenot-accessiblemandatory
rsdmFWVersionID
OBJECT-TYPE
The current version string of the RSDM FW code
1.3.6.1.4.1.4253.1.13.6.1.10VersionStringnot-accessiblemandatory
rsdmFWName
OBJECT-TYPE
RSDM's Firmware Name.
1.3.6.1.4.1.4253.1.13.6.1.11DisplayStringnot-accessiblemandatory
rsdmFWDate
OBJECT-TYPE
Date and Time of latest Firmware of the RSDM card.
1.3.6.1.4.1.4253.1.13.6.1.12DateAndTimenot-accessiblemandatory
rsdmHWVersionID
OBJECT-TYPE
The current version string of the RSDM HW code.
1.3.6.1.4.1.4253.1.13.6.1.13VersionStringnot-accessiblemandatory
rsdmHWDate
OBJECT-TYPE
Date and Time of Hardware of the RSDM card.
1.3.6.1.4.1.4253.1.13.6.1.14DateAndTimenot-accessiblemandatory
rsdmSetState
OBJECT-TYPE
Instruct the rsdm to do a warmboot. A get on this will always return an other.
1.3.6.1.4.1.4253.1.13.6.1.15RebootTypenot-accessiblemandatory
rsdmRxITUNumber
OBJECT-TYPE
Receive port's ITU wavelength number.
1.3.6.1.4.1.4253.1.13.6.1.16INTEGERnot-accessiblemandatory
rsdmTxITUNumber
OBJECT-TYPE
Transmit port's ITU wavelength number.
1.3.6.1.4.1.4253.1.13.6.1.17INTEGERnot-accessiblemandatory
rsdmRxInsertionLoss
OBJECT-TYPE
Receive port's insertion loss in dB.
1.3.6.1.4.1.4253.1.13.6.1.18DisplayStringnot-accessiblemandatory
rsdmTxInsertionLoss
OBJECT-TYPE
Transmit port's insertion loss in dB.
1.3.6.1.4.1.4253.1.13.6.1.19DisplayStringnot-accessiblemandatory
rsdmExpressLoss
OBJECT-TYPE
Insertion loss for the expressed channel through the RSDM module in dB.
1.3.6.1.4.1.4253.1.13.6.1.20DisplayStringnot-accessiblemandatory
rsdmMarginForSwitch
OBJECT-TYPE
Switching threshold in dB for protection switch to occur.
1.3.6.1.4.1.4253.1.13.6.1.21INTEGER (-40..0)not-accessiblemandatory
rsdmMinProtPowerForSwitch
OBJECT-TYPE
Minimum protection link's light power in dBm to allow protection switching to occur.
1.3.6.1.4.1.4253.1.13.6.1.22INTEGER (-40..0)not-accessiblemandatory
rsdmDeBounce
OBJECT-TYPE
Debounce in number of times to measure low light power before protection switch.
1.3.6.1.4.1.4253.1.13.6.1.23INTEGERnot-accessiblemandatory
rsdmBlackOutTime
OBJECT-TYPE
Black out time in unit of 0.1 second after protection switch to allow another protection switch to occur again.
1.3.6.1.4.1.4253.1.13.6.1.24INTEGERnot-accessiblemandatory
rsdmSwitch
OBJECT-TYPE
Instruct the RSDM to take on an action, such as: switch to link A or link B. A snmp get would always return other(1).
1.3.6.1.4.1.4253.1.13.6.1.25INTEGER {other(1), switchToLinkA(2), switchToLinkB(3), toggle(4), enableAutoSwitch(6)}not-accessiblemandatory
rsdmPathID
OBJECT-TYPE
Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
1.3.6.1.4.1.4253.1.13.6.1.26PathIdNamenot-accessiblemandatory
rsdmAdminState
OBJECT-TYPE
Administrative control over that rsdm card. Default value is enable. When disabled, no alarms/events gets generated.
1.3.6.1.4.1.4253.1.13.6.1.27INTEGER {disable(1), enable(2), na(3)}not-accessiblemandatory
rsdmPortTable
OBJECT-TYPE
This table represents the physical connection for each RSDM card's port.
1.3.6.1.4.1.4253.1.13.7not-accessiblemandatory
rsdmPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.13.7.1not-accessiblemandatory
rsdmPortCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.13.7.1.1CardShelfnot-accessiblemandatory
rsdmPortCardSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.1.13.7.1.2SlotInputnot-accessiblemandatory
rsdmPortType
OBJECT-TYPE
Type of the RSDM's port. The order is CLI compatible.
1.3.6.1.4.1.4253.1.13.7.1.3INTEGER {linkEast(1), linkWest(2), linkRx(3), linkTx(4)}not-accessiblemandatory
rsdmConnCardType
OBJECT-TYPE
Type of connection. Valid values are ocmu(2), ocmItu(3), mux(4), demux(5), mcm(8), w4cd(10), w2cmd(13), w4cm(21), osam(20), fadm(6), oppm(7), fadmb(19), ocme(24), etc... A zero will be used for no connections.
1.3.6.1.4.1.4253.1.13.7.1.4CardTypenot-accessiblemandatory
rsdmConnPort
OBJECT-TYPE
Conn port for RSDM's port.Possible values based on card types that can connect to RSDM are: OFCM/OFCD: 1/2/3/4= port index, 5=EXP, 6=OUT/IN W4CM/W4CD: 1=1510, 2=1530, 3=1550, 4=1570, 5=EXP, 6=IN/OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT OSAM: 1=IN, 2=OUT FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx FADMB: 1=A/D, 2=EXP, 3=Local, 4=Rx OCMU/OCMITU/MCM: 1=Link Tx, 2=Link Rx UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx
1.3.6.1.4.1.4253.1.13.7.1.5INTEGERnot-accessiblemandatory
rsdmConnShelf
OBJECT-TYPE
The shelf the card conn to. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.13.7.1.6ShelfInputnot-accessiblemandatory
rsdmConnSlot
OBJECT-TYPE
The slot within the shelf the card conn to.
1.3.6.1.4.1.4253.1.13.7.1.7SlotInputnot-accessiblemandatory
rtdm
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.14
rtdmBootPromVer
OBJECT-TYPE
The current version string of the RTDM Boot PROM code
1.3.6.1.4.1.4253.1.14.1VersionStringnot-accessiblemandatory
rtdmROMSize
OBJECT-TYPE
Total Size of the ROM in Kilobyes
1.3.6.1.4.1.4253.1.14.2INTEGER (0..1024)not-accessiblemandatory
rtdmNumSubDiv
OBJECT-TYPE
Number of the subdivisions of the ROM.
1.3.6.1.4.1.4253.1.14.3INTEGER (0..20)not-accessiblemandatory
rtdmSubDivTable
OBJECT-TYPE
This table represents the number of sub divisions and the size of each subdivision in ROM memory
1.3.6.1.4.1.4253.1.14.4not-accessiblemandatory
rtdmSubDivEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.14.4.1not-accessiblemandatory
rtdmSubDivIndex
OBJECT-TYPE
Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
1.3.6.1.4.1.4253.1.14.4.1.1INTEGER (0..20)not-accessiblemandatory
rtdmSubDivDescr
OBJECT-TYPE
Display Name of each Sub Division in ROM
1.3.6.1.4.1.4253.1.14.4.1.2DisplayString (SIZE(0..20))not-accessiblemandatory
rtdmSubDivSize
OBJECT-TYPE
Size of each sub division in ROM in kilobytes
1.3.6.1.4.1.4253.1.14.4.1.3INTEGER (0..1024)not-accessiblemandatory
rtdmSubDivOffset
OBJECT-TYPE
Starting address of each sub division in the ROM in HEX notation.
1.3.6.1.4.1.4253.1.14.4.1.4OCTET STRING (SIZE(0..8))not-accessiblemandatory
rtdmNumber
OBJECT-TYPE
Number of RTDM rows in the following table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.14.5INTEGERnot-accessiblemandatory
rtdmTable
OBJECT-TYPE
This table represents the information for each RTDM card
1.3.6.1.4.1.4253.1.14.6not-accessiblemandatory
rtdmEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.14.6.1not-accessiblemandatory
rtdmCardLocation
OBJECT-TYPE
Location of the RTDM card. Valid values are: Local in the same chassis, or remote to this chassis
1.3.6.1.4.1.4253.1.14.6.1.1CardLocationnot-accessiblemandatory
rtdmCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.1.14.6.1.2CardShelfnot-accessiblemandatory
rtdmCardSlot
OBJECT-TYPE
The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.14.6.1.3SlotInputnot-accessiblemandatory
rtdmModelNum
OBJECT-TYPE
Model number for RTDM.
1.3.6.1.4.1.4253.1.14.6.1.4DisplayStringnot-accessiblemandatory
rtdmOpticsMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the optics on the RTDM card
1.3.6.1.4.1.4253.1.14.6.1.5DateAndTimenot-accessiblemandatory
rtdmSerialNum
OBJECT-TYPE
Serial # of the RTDM card.
1.3.6.1.4.1.4253.1.14.6.1.6SerialStringnot-accessiblemandatory
rtdmModelType
OBJECT-TYPE
Model type of the RTDM
1.3.6.1.4.1.4253.1.14.6.1.7INTEGER {rtdm(18)}not-accessiblemandatory
rtdmHWName
OBJECT-TYPE
Display (Network) name of the RTDM Card
1.3.6.1.4.1.4253.1.14.6.1.8CardNamenot-accessiblemandatory
rtdmFWVersionID
OBJECT-TYPE
The current version string of the RTDM FW code
1.3.6.1.4.1.4253.1.14.6.1.9VersionStringnot-accessiblemandatory
rtdmCardName
OBJECT-TYPE
User configurable card name.
1.3.6.1.4.1.4253.1.14.6.1.10CardNamenot-accessiblemandatory
rtdmFWName
OBJECT-TYPE
RTDM's Firmware Name.
1.3.6.1.4.1.4253.1.14.6.1.11DisplayStringnot-accessiblemandatory
rtdmFWDate
OBJECT-TYPE
Date and Time of latest Firmware of the RTDM card
1.3.6.1.4.1.4253.1.14.6.1.12DateAndTimenot-accessiblemandatory
rtdmHWVersionID
OBJECT-TYPE
The current version string of the RTDM HW code
1.3.6.1.4.1.4253.1.14.6.1.13VersionStringnot-accessiblemandatory
rtdmHWDate
OBJECT-TYPE
Date and Time of Hardware of the RTDM card
1.3.6.1.4.1.4253.1.14.6.1.14DateAndTimenot-accessiblemandatory
rtdmSetState
OBJECT-TYPE
Instruct the rtdm to do a warmboot. A get on this will always return an other.
1.3.6.1.4.1.4253.1.14.6.1.15RebootTypenot-accessiblemandatory
rtdmCommonEInsertionLoss
OBJECT-TYPE
The RTDM Common path East's insertion loss in dB.
1.3.6.1.4.1.4253.1.14.6.1.16DisplayStringnot-accessiblemandatory
rtdmCommonWInsertionLoss
OBJECT-TYPE
The RTDM Common path West's insertion loss in dB.
1.3.6.1.4.1.4253.1.14.6.1.17DisplayStringnot-accessiblemandatory
rtdmMonEastInsertionLoss
OBJECT-TYPE
The RTDM Monitor East Path's insertion loss in dB.
1.3.6.1.4.1.4253.1.14.6.1.18DisplayStringnot-accessiblemandatory
rtdmMonWestInsertionLoss
OBJECT-TYPE
The RTDM Monitor West Path's insertion loss in dB.
1.3.6.1.4.1.4253.1.14.6.1.19DisplayStringnot-accessiblemandatory
rtdmPathID
OBJECT-TYPE
Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
1.3.6.1.4.1.4253.1.14.6.1.20PathIdNamenot-accessiblemandatory
rtdmAdminState
OBJECT-TYPE
Administrative control over that rtdm card. Default value is enable. When disabled, no alarms/events gets generated.
1.3.6.1.4.1.4253.1.14.6.1.21INTEGER {disable(1), enable(2), na(3)}not-accessiblemandatory
rtdmPortTable
OBJECT-TYPE
This table represents the physical connection for each RTDM card's port.
1.3.6.1.4.1.4253.1.14.7not-accessiblemandatory
rtdmPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.14.7.1not-accessiblemandatory
rtdmPortCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.14.7.1.1CardShelfnot-accessiblemandatory
rtdmPortCardSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.1.14.7.1.2SlotInputnot-accessiblemandatory
rtdmPortType
OBJECT-TYPE
Type of the RTDM's port. The order is CLI compatible.
1.3.6.1.4.1.4253.1.14.7.1.3INTEGER {localRx(1)}not-accessiblemandatory
rtdmConnCardType
OBJECT-TYPE
Type of connection. Valid values are ocmu(2), ocmItu(3), mux(4), demux(5), mcm(8), w4cd(10), w2cmd(13), w4cm(21), osam(20), fadm(6), oppm(7), fadmb(19), ocme(24), etc...
1.3.6.1.4.1.4253.1.14.7.1.4INTEGER (0..30)not-accessiblemandatory
rtdmConnPort
OBJECT-TYPE
Conn port for RTDM's port.Possible values based on card types that can connect to RTDM are: OFCM/OFCD: 1/2/3/4= port index, 5=EXP, 6=OUT/IN W4CM/W4CD: 1=1510, 2=1530, 3=1550, 4=1570, 5=EXP, 6=IN/OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT OSAM: 1=IN, 2=OUT FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx FADMB: 1=A/D, 2=EXP, 3=Local, 4=Rx OCMU/OCMITU/MCM: 1=Link Tx, 2=Link Rx UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx
1.3.6.1.4.1.4253.1.14.7.1.5INTEGERnot-accessiblemandatory
rtdmConnShelf
OBJECT-TYPE
The shelf the card conn to. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.14.7.1.6ShelfInputnot-accessiblemandatory
rtdmConnSlot
OBJECT-TYPE
The slot within the shelf the card conn to. A zero will be used for no connections.
1.3.6.1.4.1.4253.1.14.7.1.7SlotInputnot-accessiblemandatory
osam
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.15
osamBootPromVer
OBJECT-TYPE
The current version string of the osam boot prom code.
1.3.6.1.4.1.4253.1.15.1VersionStringnot-accessiblemandatory
osamROMSize
OBJECT-TYPE
Total Size of the ROM in Kilobytes.
1.3.6.1.4.1.4253.1.15.2INTEGER (0..1024)not-accessiblemandatory
osamNumSubDiv
OBJECT-TYPE
Number of the ROM's subdivisions.
1.3.6.1.4.1.4253.1.15.3INTEGER (0..20)not-accessiblemandatory
osamSubDivTable
OBJECT-TYPE
This table represents the number of sub divisions and the size of each subdivision in ROM memory
1.3.6.1.4.1.4253.1.15.4not-accessiblemandatory
osamSubDivEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.15.4.1not-accessiblemandatory
osamSubDivIndex
OBJECT-TYPE
Integer ID of each subdivision.
1.3.6.1.4.1.4253.1.15.4.1.1INTEGER (0..20)not-accessiblemandatory
osamSubDivDescr
OBJECT-TYPE
Display name of each subdivision.
1.3.6.1.4.1.4253.1.15.4.1.2DisplayString (SIZE(0..20))not-accessiblemandatory
osamSubDivSize
OBJECT-TYPE
Size of each subdivision in Kbytes.
1.3.6.1.4.1.4253.1.15.4.1.3INTEGER (0..1024)not-accessiblemandatory
osamSubDivOffset
OBJECT-TYPE
Starting address of each sub division in HEX format.
1.3.6.1.4.1.4253.1.15.4.1.4OCTET STRING (SIZE(0..8))not-accessiblemandatory
osamNumber
OBJECT-TYPE
Number of rows in the osam table.
1.3.6.1.4.1.4253.1.15.5INTEGER (0..32)read-onlymandatory
osamTable
OBJECT-TYPE
This table represents the information for each osam card
1.3.6.1.4.1.4253.1.15.6not-accessiblemandatory
osamEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.15.6.1not-accessiblemandatory
osamCardLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.15.6.1.1CardLocationread-onlymandatory
osamCardShelf
OBJECT-TYPE
The shelf number in which the module is plugged in.
1.3.6.1.4.1.4253.1.15.6.1.2CardShelfread-onlymandatory
osamCardSlot
OBJECT-TYPE
The slot number in which the module is plugged in. If a 0 is written into this mib element, the module will be deleted from the system.
1.3.6.1.4.1.4253.1.15.6.1.3INTEGER (0..16)read-writemandatory
osamModelNum
OBJECT-TYPE
Manufacturing model number of the module.
1.3.6.1.4.1.4253.1.15.6.1.4ModelNumread-onlymandatory
osamSerialNum
OBJECT-TYPE
Unique serial number of the module.
1.3.6.1.4.1.4253.1.15.6.1.5SerialStringread-onlymandatory
osamModelType
OBJECT-TYPE
Model type of the module.
1.3.6.1.4.1.4253.1.15.6.1.6CardTyperead-onlymandatory
osamHWName
OBJECT-TYPE
Manufacturing Hardware name of the module.
1.3.6.1.4.1.4253.1.15.6.1.7CardNameread-onlymandatory
osamHWVersionID
OBJECT-TYPE
The current hardware version string of the module.
1.3.6.1.4.1.4253.1.15.6.1.8VersionStringread-onlymandatory
osamHWDate
OBJECT-TYPE
Date of manufacturing of the electronics portion of the module.
1.3.6.1.4.1.4253.1.15.6.1.9DateAndTimeread-onlymandatory
osamFWName
OBJECT-TYPE
Manufacturing Firmware name of the module.
1.3.6.1.4.1.4253.1.15.6.1.10CardNameread-onlymandatory
osamFWVersionID
OBJECT-TYPE
The current firmware version string of the module.
1.3.6.1.4.1.4253.1.15.6.1.11VersionStringread-onlymandatory
osamFWDate
OBJECT-TYPE
Release date for the firmware of the module.
1.3.6.1.4.1.4253.1.15.6.1.12DateAndTimeread-onlymandatory
osamCardName
OBJECT-TYPE
User configurable card name for the module.
1.3.6.1.4.1.4253.1.15.6.1.13CardNameread-writemandatory
osamSetState
OBJECT-TYPE
Instruct the osam module to do a reset. A get on this will always return other.
1.3.6.1.4.1.4253.1.15.6.1.14RebootTyperead-writemandatory
osamLaserState
OBJECT-TYPE
The operational state of the laser.
1.3.6.1.4.1.4253.1.15.6.1.15FlagTyperead-onlymandatory
osamOperationMode
OBJECT-TYPE
Operation mode of the module. powerControlled(3) is not supported by OSAM modules. currentControlled(1) is not supported OSAM-HP/LP modules.
1.3.6.1.4.1.4253.1.15.6.1.16INTEGER {currentControlled(1), gainControlled(2), powerControlled(3)}read-writemandatory
osamLaserBiasCurrent
OBJECT-TYPE
Constant current in mA to be used by the module when the operation mode is set to currentControlled. This value can't be set if operation mode is set to gainControlled. Applicable only to OSAM module
1.3.6.1.4.1.4253.1.15.6.1.17INTEGER (40..200)read-writemandatory
osamAmplifierGain
OBJECT-TYPE
Constant gain in dB to be used by the module when the operation mode is set to gainControlled. This value can't be set if operation mode is set to currentControlled. Not applicable to OSAM-HP/LP module
1.3.6.1.4.1.4253.1.15.6.1.18INTEGER (0..30)read-writemandatory
osamConfigCommit
OBJECT-TYPE
This allows the current module configuration to be stored in permanent storage.
1.3.6.1.4.1.4253.1.15.6.1.19INTEGER {other(1), save(2)}read-writemandatory
osamNoiseFigure
OBJECT-TYPE
The calibrated noise figure of the gain block in dB. Applicable only to OSAM module
1.3.6.1.4.1.4253.1.15.6.1.20INTEGER (0..10)read-onlymandatory
osamPathID
OBJECT-TYPE
Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
1.3.6.1.4.1.4253.1.15.6.1.21PathIdNameread-writemandatory
osamAdminState
OBJECT-TYPE
Administrative control over that osam card. Default value is enable. When disabled, no alarms/events gets generated.
1.3.6.1.4.1.4253.1.15.6.1.22INTEGER {disable(1), enable(2), na(3)}read-writemandatory
osam2NoiseFigure
OBJECT-TYPE
The calibrated noise figure of the gain block in dBm. Applicable only to OSAM-HP/LP module
1.3.6.1.4.1.4253.1.15.6.1.23DisplayStringread-onlymandatory
osam2GainReq
OBJECT-TYPE
Constant gain in dB to be used by the module when the operation mode is set to gainControlled. This value can't be set if operation mode is set to powerControlled. Range is 0-16.5db(LP) and 0-23.3db(HP) Applicable only to OSAM-HP/LP module
1.3.6.1.4.1.4253.1.15.6.1.24DisplayStringread-writemandatory
osam2OpPowerReq
OBJECT-TYPE
Constant output power in dBm to be used by the module when the operation mode is set to powerControlled. This value can't be set if operation mode is set to gainControlled. Range is 0-9dbm (LP) and 0-18dbm(HP) Applicable only to OSAM-HP/LP module
1.3.6.1.4.1.4253.1.15.6.1.25DisplayStringread-writemandatory
osamCleiNum
OBJECT-TYPE
CLEI number of the osam Card.
1.3.6.1.4.1.4253.1.15.6.1.26DisplayStringread-onlymandatory
osamNumPorts
OBJECT-TYPE
Total port numbers on each OSAM card.
1.3.6.1.4.1.4253.1.15.6.1.27INTEGERread-onlymandatory
osamPortTable
OBJECT-TYPE
This table represents the physical connection for each OSAM card's port.
1.3.6.1.4.1.4253.1.15.7not-accessiblemandatory
osamPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.15.7.1not-accessiblemandatory
osamPortCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.15.7.1.1CardShelfread-onlymandatory
osamPortCardSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.1.15.7.1.2SlotInputread-onlymandatory
osamPortType
OBJECT-TYPE
Type of the OSAM's port.
1.3.6.1.4.1.4253.1.15.7.1.3INTEGER {in(1), out(2)}read-writemandatory
osamConnCardType
OBJECT-TYPE
Module type connectioned to osam port.
1.3.6.1.4.1.4253.1.15.7.1.4CardTyperead-writemandatory
osamConnPort
OBJECT-TYPE
Conn port for OSAM's port. Possible values based on card types that can be connected to OSAM are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx.
1.3.6.1.4.1.4253.1.15.7.1.5INTEGERread-writemandatory
osamConnShelf
OBJECT-TYPE
The shelf the card conn to. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.15.7.1.6ShelfInputread-writemandatory
osamConnSlot
OBJECT-TYPE
The slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0.
1.3.6.1.4.1.4253.1.15.7.1.7SlotInputread-writemandatory
osamPortCardType
OBJECT-TYPE
Type of OSAM module.
1.3.6.1.4.1.4253.1.15.7.1.8CardTyperead-onlymandatory
osamConnLocation
OBJECT-TYPE
The chassis's location of the card connected to.
1.3.6.1.4.1.4253.1.15.7.1.9CardLocationread-onlymandatory
osamConnChassisID
OBJECT-TYPE
Chassis ID of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the chassis Id of the local node.
1.3.6.1.4.1.4253.1.15.7.1.10DisplayStringread-onlymandatory
osamConnSystemName
OBJECT-TYPE
System Name of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the sysetem name of the local node.
1.3.6.1.4.1.4253.1.15.7.1.11DisplayStringread-onlymandatory
osamConnIpAddress
OBJECT-TYPE
IpAddress of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the IP address of the node.
1.3.6.1.4.1.4253.1.15.7.1.12IpAddressread-onlymandatory
rsm
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.16
rsmBootPromVer
OBJECT-TYPE
The current version string of the rsm Boot PROM code
1.3.6.1.4.1.4253.1.16.1VersionStringnot-accessiblemandatory
rsmROMSize
OBJECT-TYPE
Total Size of the ROM in Kilobyes
1.3.6.1.4.1.4253.1.16.2INTEGER (0..1024)not-accessiblemandatory
rsmNumSubDiv
OBJECT-TYPE
Number of the subdivisions of the ROM.
1.3.6.1.4.1.4253.1.16.3INTEGER (0..20)not-accessiblemandatory
rsmSubDivTable
OBJECT-TYPE
This table represents the number of sub divisions and the size of each subdivision in ROM memory
1.3.6.1.4.1.4253.1.16.4not-accessiblemandatory
rsmSubDivEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.16.4.1not-accessiblemandatory
rsmSubDivIndex
OBJECT-TYPE
Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
1.3.6.1.4.1.4253.1.16.4.1.1INTEGER (0..20)not-accessiblemandatory
rsmSubDivDescr
OBJECT-TYPE
Display Name of each Sub Division in ROM
1.3.6.1.4.1.4253.1.16.4.1.2DisplayString (SIZE(0..20))not-accessiblemandatory
rsmSubDivSize
OBJECT-TYPE
Size of each sub division in ROM in kilobytes
1.3.6.1.4.1.4253.1.16.4.1.3INTEGER (0..1024)not-accessiblemandatory
rsmSubDivOffset
OBJECT-TYPE
Starting address of each sub division in the ROM in HEX notation.
1.3.6.1.4.1.4253.1.16.4.1.4OCTET STRING (SIZE(0..8))not-accessiblemandatory
rsmNumber
OBJECT-TYPE
Number of RSM rows in the following table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.16.5INTEGERread-onlymandatory
rsmTable
OBJECT-TYPE
This table represents the information for each RSM card
1.3.6.1.4.1.4253.1.16.6not-accessiblemandatory
rsmEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.16.6.1not-accessiblemandatory
rsmCardLocation
OBJECT-TYPE
Location of the RSM card. Valid values are: Local in the same chassis.
1.3.6.1.4.1.4253.1.16.6.1.1CardLocationread-onlymandatory
rsmCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.16.6.1.2CardShelfread-onlymandatory
rsmCardSlot
OBJECT-TYPE
The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.16.6.1.3SlotInputread-writemandatory
rsmModelNum
OBJECT-TYPE
RSM's model number.
1.3.6.1.4.1.4253.1.16.6.1.4DisplayStringread-onlymandatory
rsmOpticsMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the optics on the RSM card.
1.3.6.1.4.1.4253.1.16.6.1.5DateAndTimenot-accessiblemandatory
rsmSerialNum
OBJECT-TYPE
Serial # of the RSM card.
1.3.6.1.4.1.4253.1.16.6.1.6SerialStringread-onlymandatory
rsmModelType
OBJECT-TYPE
Model type of the RSM.
1.3.6.1.4.1.4253.1.16.6.1.7CardTyperead-onlymandatory
rsmHWName
OBJECT-TYPE
Manufacturing Hardware name of the RSM Card.
1.3.6.1.4.1.4253.1.16.6.1.8CardNameread-onlymandatory
rsmCardName
OBJECT-TYPE
User configurable card name.
1.3.6.1.4.1.4253.1.16.6.1.9CardNameread-writemandatory
rsmFWName
OBJECT-TYPE
RSM's Firmware Name.
1.3.6.1.4.1.4253.1.16.6.1.10DisplayStringread-onlymandatory
rsmFWVersionID
OBJECT-TYPE
The current version string of the RSM FW code.
1.3.6.1.4.1.4253.1.16.6.1.11VersionStringread-onlymandatory
rsmFWDate
OBJECT-TYPE
Date and Time of latest Firmware of the RSM card.
1.3.6.1.4.1.4253.1.16.6.1.12DateAndTimeread-onlymandatory
rsmSetState
OBJECT-TYPE
Instruct the rsm to do a warmboot. A get on this will always return an other.
1.3.6.1.4.1.4253.1.16.6.1.13RebootTyperead-writemandatory
rsmRxInsertionLoss
OBJECT-TYPE
Insertion loss for Rx Path.
1.3.6.1.4.1.4253.1.16.6.1.14DisplayStringread-onlymandatory
rsmRxComInsertionLoss
OBJECT-TYPE
Insertion loss for Rx Com Path.
1.3.6.1.4.1.4253.1.16.6.1.15DisplayStringread-onlymandatory
rsmWorkingWavelength
OBJECT-TYPE
The RSM ITU number.
1.3.6.1.4.1.4253.1.16.6.1.16INTEGERread-onlymandatory
rsmLinkAPathID
OBJECT-TYPE
Rsm LinkA Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
1.3.6.1.4.1.4253.1.16.6.1.17PathIdNameread-writemandatory
rsmLinkBPathID
OBJECT-TYPE
Rsm LinkB Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
1.3.6.1.4.1.4253.1.16.6.1.18PathIdNameread-writemandatory
rsmAdminState
OBJECT-TYPE
Administrative control over that rsm card. Default value is enable. When disabled, no alarms/events gets generated.
1.3.6.1.4.1.4253.1.16.6.1.19INTEGER {disable(1), enable(2), na(3)}read-writemandatory
rsmCleiNum
OBJECT-TYPE
CLEI number of the rsm Card.
1.3.6.1.4.1.4253.1.16.6.1.20DisplayStringread-onlymandatory
rsmNumPorts
OBJECT-TYPE
Total port numbers on each RSM card.
1.3.6.1.4.1.4253.1.16.6.1.21INTEGERread-onlymandatory
rsmPortTable
OBJECT-TYPE
This table represents the information for each RSM card's port.
1.3.6.1.4.1.4253.1.16.7not-accessiblemandatory
rsmPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.16.7.1not-accessiblemandatory
rsmPortCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.16.7.1.1CardShelfread-onlymandatory
rsmPortCardSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.1.16.7.1.2SlotInputread-onlymandatory
rsmPortType
OBJECT-TYPE
Type of the RSM's port. The order is CLI compatible.
1.3.6.1.4.1.4253.1.16.7.1.3INTEGER {localARx(1), localATx(2), localBRx(3), localBTx(4)}read-onlymandatory
rsmConnCardType
OBJECT-TYPE
Module type connected to rsm port. The valid module types are OCM10G/OCME/OCMITU/OCMU.
1.3.6.1.4.1.4253.1.16.7.1.4CardTyperead-writemandatory
rsmConnShelf
OBJECT-TYPE
The shelf the card conn to. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.16.7.1.5ShelfInputread-writemandatory
rsmConnSlot
OBJECT-TYPE
The slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0.
1.3.6.1.4.1.4253.1.16.7.1.6SlotInputread-writemandatory
rsmConnPort
OBJECT-TYPE
Conn port for RSM's port. Only OCM10G/OCME/OCMITU/OCMU can be connected to RSM. The possible values are: OCM10G/OCME/OCMITU/OCMU: 3=CPE Tx, 4=CPE Rx
1.3.6.1.4.1.4253.1.16.7.1.7INTEGERread-writemandatory
upsm
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.17
upsmBootPromVer
OBJECT-TYPE
The current version string of the rsm Boot PROM code
1.3.6.1.4.1.4253.1.17.1VersionStringnot-accessiblemandatory
upsmROMSize
OBJECT-TYPE
Total Size of the ROM in Kilobyes
1.3.6.1.4.1.4253.1.17.2INTEGER (0..1024)not-accessiblemandatory
upsmNumSubDiv
OBJECT-TYPE
Number of the subdivisions of the ROM.
1.3.6.1.4.1.4253.1.17.3INTEGER (0..20)not-accessiblemandatory
upsmSubDivTable
OBJECT-TYPE
This table represents the number of sub divisions and the size of each subdivision in ROM memory
1.3.6.1.4.1.4253.1.17.4not-accessiblemandatory
upsmSubDivEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.17.4.1not-accessiblemandatory
upsmSubDivIndex
OBJECT-TYPE
Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
1.3.6.1.4.1.4253.1.17.4.1.1INTEGER (0..20)not-accessiblemandatory
upsmSubDivDescr
OBJECT-TYPE
Display Name of each Sub Division in ROM
1.3.6.1.4.1.4253.1.17.4.1.2DisplayString (SIZE(0..20))not-accessiblemandatory
upsmSubDivSize
OBJECT-TYPE
Size of each sub division in ROM in kilobytes
1.3.6.1.4.1.4253.1.17.4.1.3INTEGER (0..1024)not-accessiblemandatory
upsmSubDivOffset
OBJECT-TYPE
Starting address of each sub division in the ROM in HEX notation.
1.3.6.1.4.1.4253.1.17.4.1.4OCTET STRING (SIZE(0..8))not-accessiblemandatory
upsmNumber
OBJECT-TYPE
Number of UPSM rows in the following table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.17.5INTEGERread-onlymandatory
upsmTable
OBJECT-TYPE
This table represents the information for each UPSM card
1.3.6.1.4.1.4253.1.17.6not-accessiblemandatory
upsmEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.17.6.1not-accessiblemandatory
upsmCardLocation
OBJECT-TYPE
Location of the UPSM card. Valid values are: Local in the same chassis.
1.3.6.1.4.1.4253.1.17.6.1.1CardLocationread-onlymandatory
upsmCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.17.6.1.2INTEGERread-onlymandatory
upsmCardSlot
OBJECT-TYPE
The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.17.6.1.3INTEGERread-writemandatory
upsmModelNum
OBJECT-TYPE
UPSM's model number.
1.3.6.1.4.1.4253.1.17.6.1.4DisplayStringread-onlymandatory
upsmOpticsMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the optics on the UPSM card.
1.3.6.1.4.1.4253.1.17.6.1.5DateAndTimenot-accessiblemandatory
upsmSerialNum
OBJECT-TYPE
Serial # of the UPSM card.
1.3.6.1.4.1.4253.1.17.6.1.6SerialStringread-onlymandatory
upsmModelType
OBJECT-TYPE
Model type of the UPSM.
1.3.6.1.4.1.4253.1.17.6.1.7CardTyperead-onlymandatory
upsmHWName
OBJECT-TYPE
Manufacturing Hardware name of the UPSM Card.
1.3.6.1.4.1.4253.1.17.6.1.8CardNameread-onlymandatory
upsmCardName
OBJECT-TYPE
User configurable card name.
1.3.6.1.4.1.4253.1.17.6.1.9CardNameread-writemandatory
upsmFWName
OBJECT-TYPE
UPSM's Firmware Name.
1.3.6.1.4.1.4253.1.17.6.1.10DisplayStringread-onlymandatory
upsmFWVersionID
OBJECT-TYPE
The current version string of the UPSM FW code.
1.3.6.1.4.1.4253.1.17.6.1.11VersionStringread-onlymandatory
upsmFWDate
OBJECT-TYPE
Date and Time of latest Firmware of the UPSM card.
1.3.6.1.4.1.4253.1.17.6.1.12DateAndTimeread-onlymandatory
upsmSetState
OBJECT-TYPE
Instruct the upsm to do a warmboot. A get on this will always return an other.
1.3.6.1.4.1.4253.1.17.6.1.13RebootTyperead-writemandatory
upsmRxInsertionLoss
OBJECT-TYPE
Insertion loss for Rx Path.
1.3.6.1.4.1.4253.1.17.6.1.14DisplayStringread-onlymandatory
upsmTxInsertionLoss
OBJECT-TYPE
Insertion loss for Tx Path.
1.3.6.1.4.1.4253.1.17.6.1.15DisplayStringread-onlymandatory
upsmMarginForSwitch
OBJECT-TYPE
The UPSM switching threshold for protection switch to occur. The limit is from -32 to -6. Switching threshold must be 1 dBm or more less than the minimum switch power.
1.3.6.1.4.1.4253.1.17.6.1.16INTEGER (-32..-6)read-writemandatory
upsmMinProtPowerForSwitch
OBJECT-TYPE
The minimum protection link power to allow protection switch to function. The limit is from -30 to -5. This value should be 1 dBm or more greater than the switch margin.
1.3.6.1.4.1.4253.1.17.6.1.17INTEGER (-30..-5)read-writemandatory
upsmDebounce
OBJECT-TYPE
The number of times to measure low power condition before performing protection switch.
1.3.6.1.4.1.4253.1.17.6.1.18INTEGERread-onlymandatory
upsmBlackOutTime
OBJECT-TYPE
The time after protection switch before allowing another protection switch.
1.3.6.1.4.1.4253.1.17.6.1.19INTEGERread-onlymandatory
upsmSwitch
OBJECT-TYPE
The Link switch control. switchToLinkA or switchToLinkB option would disable auto switch functionality. Auto switch functionality can be turned on by setting to enableAutoSwitch option
1.3.6.1.4.1.4253.1.17.6.1.20INTEGER {other(1), switchToLinkA(2), switchToLinkB(3), toggle(4), enableAutoSwitch(6), enableSwitchtoLinkA(7), enableSwitchtoLinkB(8)}read-writemandatory
upsmLinkAPathID
OBJECT-TYPE
Upsm LinkA Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
1.3.6.1.4.1.4253.1.17.6.1.21PathIdNameread-writemandatory
upsmLinkBPathID
OBJECT-TYPE
Upsm LinkB Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
1.3.6.1.4.1.4253.1.17.6.1.22PathIdNameread-writemandatory
upsmAdminState
OBJECT-TYPE
Administrative control over that upsm card. Default value is enable. When disabled, no alarms/events gets generated.
1.3.6.1.4.1.4253.1.17.6.1.23INTEGER {disable(1), enable(2), na(3)}read-writemandatory
upsmCleiNum
OBJECT-TYPE
CLEI number of the upsm Card.
1.3.6.1.4.1.4253.1.17.6.1.24DisplayStringread-onlymandatory
upsmSwitchState
OBJECT-TYPE
The switching state. Switching state may be either auto or forced. The auto state means automatic switching is enabled. Forced state means swithcing is disabled and has been forced to the current active link.
1.3.6.1.4.1.4253.1.17.6.1.25INTEGER {auto(1), forced(2)}read-onlymandatory
upsmNumPorts
OBJECT-TYPE
Total port numbers on each UPSM card.
1.3.6.1.4.1.4253.1.17.6.1.26INTEGERread-onlymandatory
upsmPortTable
OBJECT-TYPE
This table represents the information for each UPSM card's port.
1.3.6.1.4.1.4253.1.17.7not-accessiblemandatory
upsmPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.17.7.1not-accessiblemandatory
upsmPortCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.17.7.1.1CardShelfread-onlymandatory
upsmPortCardSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.1.17.7.1.2SlotInputread-onlymandatory
upsmPortType
OBJECT-TYPE
Type of the UPSM's port. The order is CLI compatible.
1.3.6.1.4.1.4253.1.17.7.1.3INTEGER {linkATx(1), linkARx(2), linkBTx(3), linkBRx(4), localTx(5), localRx(6)}read-onlymandatory
upsmConnLocation
OBJECT-TYPE
The chassis's location of the card conn to.
1.3.6.1.4.1.4253.1.17.7.1.4CardLocationread-writemandatory
upsmConnIpAddress
OBJECT-TYPE
IpAddress of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the IP address of the node
1.3.6.1.4.1.4253.1.17.7.1.5IpAddressread-writemandatory
upsmConnChassisID
OBJECT-TYPE
Chassis ID of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the chassis Id of the local node
1.3.6.1.4.1.4253.1.17.7.1.6DisplayString (SIZE(0..16))read-writemandatory
upsmConnSystemName
OBJECT-TYPE
System Name of the connected node. User config. If local connection, a set on it would return an error; would be automatically be set to the sysetem name of the local node.
1.3.6.1.4.1.4253.1.17.7.1.7DisplayString (SIZE(0..32))read-writemandatory
upsmConnCardType
OBJECT-TYPE
Module type connected to upsm port.
1.3.6.1.4.1.4253.1.17.7.1.8CardTyperead-writemandatory
upsmConnPort
OBJECT-TYPE
Conn port for UPSM's port. Possible values based on card types that can connect to UPSM are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx.
1.3.6.1.4.1.4253.1.17.7.1.9INTEGERread-writemandatory
upsmConnShelf
OBJECT-TYPE
The shelf the card conn to. Valid values are: 1 to 2.
1.3.6.1.4.1.4253.1.17.7.1.10ShelfInputread-writemandatory
upsmConnSlot
OBJECT-TYPE
The slot within the shelf the card conn to. To delete a connection associated with a specified port, set this variable to 0.
1.3.6.1.4.1.4253.1.17.7.1.11SlotInputread-writemandatory
mcmesc
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.18
mcmescBootPromVer
OBJECT-TYPE
The current version string of the mcmesc Boot PROM code
1.3.6.1.4.1.4253.1.18.1VersionStringnot-accessiblemandatory
mcmescROMSize
OBJECT-TYPE
Total Size of the ROM in Kilobyes
1.3.6.1.4.1.4253.1.18.2INTEGER (0..1024)not-accessiblemandatory
mcmescNumSubDiv
OBJECT-TYPE
Number of the subdivisions of the ROM.
1.3.6.1.4.1.4253.1.18.3INTEGER (0..20)not-accessiblemandatory
mcmescSubDivTable
OBJECT-TYPE
This table represents the number of sub divisions and the size of each subdivision in ROM memory
1.3.6.1.4.1.4253.1.18.4not-accessiblemandatory
mcmescSubDivEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.18.4.1not-accessiblemandatory
mcmescSubDivIndex
OBJECT-TYPE
Integer ID of each sub division in the ROM. The order of numbering is from the top of the ROM to the bottom of the ROM.
1.3.6.1.4.1.4253.1.18.4.1.1INTEGER (0..20)not-accessiblemandatory
mcmescSubDivDescr
OBJECT-TYPE
Display Name of each Sub Division in ROM
1.3.6.1.4.1.4253.1.18.4.1.2DisplayString (SIZE(0..20))not-accessiblemandatory
mcmescSubDivSize
OBJECT-TYPE
Size of each sub division in ROM in kilobytes
1.3.6.1.4.1.4253.1.18.4.1.3INTEGER (0..1024)not-accessiblemandatory
mcmescSubDivOffset
OBJECT-TYPE
Starting address of each sub division in the ROM in HEX notation.
1.3.6.1.4.1.4253.1.18.4.1.4OCTET STRING (SIZE(0..8))not-accessiblemandatory
mcmescNumber
OBJECT-TYPE
Number of rows in the following table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.18.5INTEGERread-onlymandatory
mcmescTable
OBJECT-TYPE
This table represents the information for each mcmesc module
1.3.6.1.4.1.4253.1.18.6not-accessiblemandatory
mcmescEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.18.6.1not-accessiblemandatory
mcmescCardLocation
OBJECT-TYPE
Location of the mcmesc Module.
1.3.6.1.4.1.4253.1.18.6.1.1CardLocationread-onlymandatory
mcmescCardShelf
OBJECT-TYPE
The shelf of the mcmesc is in. Valid values are: 1..2
1.3.6.1.4.1.4253.1.18.6.1.2CardShelfread-onlymandatory
mcmescCardSlot
OBJECT-TYPE
The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.18.6.1.3SlotInputread-writemandatory
mcmescMfgDate
OBJECT-TYPE
Date and Time of calibration of the mcmesc card
1.3.6.1.4.1.4253.1.18.6.1.4DateAndTimeread-onlymandatory
mcmescSerialNum
OBJECT-TYPE
Serial # of the mcmesc card.
1.3.6.1.4.1.4253.1.18.6.1.5SerialStringread-onlymandatory
mcmescModelType
OBJECT-TYPE
Model type of the mcmesc
1.3.6.1.4.1.4253.1.18.6.1.6CardTyperead-onlymandatory
mcmescModelNum
OBJECT-TYPE
Model number of the MCMESC card. Up to 15 characters
1.3.6.1.4.1.4253.1.18.6.1.7DisplayStringread-onlymandatory
mcmescName
OBJECT-TYPE
Display (Network) name of the MCMESC Module
1.3.6.1.4.1.4253.1.18.6.1.8CardNameread-writemandatory
mcmescHWName
OBJECT-TYPE
Display Hardware name of the MCMESC Card.
1.3.6.1.4.1.4253.1.18.6.1.9CardNameread-onlymandatory
mcmescNumPorts
OBJECT-TYPE
Total port numbers of MCM module.
1.3.6.1.4.1.4253.1.18.6.1.10INTEGERread-onlymandatory
mcmescFWVersionID
OBJECT-TYPE
The current version string of the MCMESC FW code
1.3.6.1.4.1.4253.1.18.6.1.11VersionStringread-onlymandatory
mcmesc2ndFWVersionID
OBJECT-TYPE
The version string of the MCMESC second FW code
1.3.6.1.4.1.4253.1.18.6.1.12VersionStringread-onlymandatory
mcmescFPGAVersionID
OBJECT-TYPE
The current version string of the MCMESC FPGA code
1.3.6.1.4.1.4253.1.18.6.1.13VersionStringread-onlymandatory
mcmesc2ndFPGAVersionID
OBJECT-TYPE
The version string of the MCMESC second FPGA code
1.3.6.1.4.1.4253.1.18.6.1.14VersionStringread-onlymandatory
mcmescBoardSerialNum
OBJECT-TYPE
Serial # of the MCMESC board.
1.3.6.1.4.1.4253.1.18.6.1.15SerialStringread-onlymandatory
mcmescBoardVersionID
OBJECT-TYPE
The version string of the MCMESC board
1.3.6.1.4.1.4253.1.18.6.1.16VersionStringread-onlymandatory
mcmescDaughterBoard1SerialNum
OBJECT-TYPE
Serial # of the MCMESC daughter board 1.
1.3.6.1.4.1.4253.1.18.6.1.17SerialStringread-onlymandatory
mcmescDaughterBoard1VersionID
OBJECT-TYPE
The version string of the MCMESC daughter board 1
1.3.6.1.4.1.4253.1.18.6.1.18VersionStringread-onlymandatory
mcmescDaughterBoard2SerialNum
OBJECT-TYPE
Serial # of the MCMESC daughter board 2.
1.3.6.1.4.1.4253.1.18.6.1.19SerialStringread-onlymandatory
mcmescDaughterBoard2VersionID
OBJECT-TYPE
The version string of the MCMESC daughter board 2
1.3.6.1.4.1.4253.1.18.6.1.20VersionStringread-onlymandatory
mcmescCleiNum
OBJECT-TYPE
CLEI number of the MCMESC Card.
1.3.6.1.4.1.4253.1.18.6.1.21DisplayStringread-onlymandatory
mcmescLinkWavelength
OBJECT-TYPE
Link Wavelength of the MCMESC card
1.3.6.1.4.1.4253.1.18.6.1.22DisplayStringread-onlymandatory
mcmescLinkSfpSerialNum
OBJECT-TYPE
Link port's SFP serial number.
1.3.6.1.4.1.4253.1.18.6.1.23SfpSerialStringread-onlymandatory
mcmescAdminState
OBJECT-TYPE
Administrative control over that MCMESC card. Default value is enable. When disabled, no alarms/events gets generated.
1.3.6.1.4.1.4253.1.18.6.1.24INTEGER {disable(1), enable(2), na(3)}read-writemandatory
mcmescLinkName
OBJECT-TYPE
Link name for fiber between the local and the remote MCMESC card.
1.3.6.1.4.1.4253.1.18.6.1.25LinkNameread-writemandatory
mcmescPathID
OBJECT-TYPE
Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
1.3.6.1.4.1.4253.1.18.6.1.26PathIdNameread-writemandatory
mcmescOverride
OBJECT-TYPE
MPM overrides the settings stored on MCMESC card upon detecting it. Default value is no. Not applicable to remote MCMESC.
1.3.6.1.4.1.4253.1.18.6.1.27INTEGER {yes(1), no(2), na(3)}read-writemandatory
mcmescPerfInterval
OBJECT-TYPE
The interval, in seconds, in which MCMESC collects the performance data, ranging 60 to 3600.
1.3.6.1.4.1.4253.1.18.6.1.28INTEGER (60..3600)read-writemandatory
mcmescCpeRxSigLowThreshold
OBJECT-TYPE
The threshold of reporting CPE port Rx signal low alarm, in dBm, ranging from -29 to -7.
1.3.6.1.4.1.4253.1.18.6.1.29INTEGER (-29..-7)read-writemandatory
mcmescLinkRxSigLowThreshold
OBJECT-TYPE
The threshold of reporting Link Rx signal low alarm, in dBm, ranging from -29 to -7.
1.3.6.1.4.1.4253.1.18.6.1.30INTEGER (-29..-7)read-writemandatory
mcmescCpeErrEventThreshold
OBJECT-TYPE
The threshold of reporting CPE error event, in the form of 1.0E-x. Only x needs to be set and will be read. The range of x is from 5 to 15, however, input should be an absolute value if using mib browser. This threshold should be lower than the value of mcmescCpeErrAlarmThreshold, i.e., the absolute value should be higher than of mcmescCpeErrAlarmThreshold.
1.3.6.1.4.1.4253.1.18.6.1.31INTEGER (5..15)read-writemandatory
mcmescCpeErrAlarmThreshold
OBJECT-TYPE
The threshold of reporting CPE error alarm, in the form of 1.0E-x. The range of x is from 4 to 14, however, input should be an absolute value if using mib browser. This threshold should be higher than the value of mcmescCpeErrEventThreshold, i.e., the absolute value should be lower than of mcmescCpeErrEventThreshold.
1.3.6.1.4.1.4253.1.18.6.1.32INTEGER (4..14)read-writemandatory
mcmescLinkErrEventThreshold
OBJECT-TYPE
The threshold of reporting LINK error event, in the form of 1.0E-x. The range of x is from 5 to 15, however, input should be an absolute value if using mib browser. This threshold should be lower than the value of mcmescLinkErrAlarmThreshold, i.e., the absolute value should be higher than of mcmescLinkErrAlarmThreshold.
1.3.6.1.4.1.4253.1.18.6.1.33INTEGER (5..15)read-writemandatory
mcmescLinkErrAlarmThreshold
OBJECT-TYPE
The threshold of reporting LINK error alarm, in the form of 1.0E-x. The range of x is from 4 to 14, however, input should be an absolute value if using mib browser. This threshold should be higher than the value of mcmescLinkErrEventThreshold, i.e., the absolute value should be lower than of mcmescLinkErrEventThreshold.
1.3.6.1.4.1.4253.1.18.6.1.34INTEGER (4..14)read-writemandatory
mcmescTestSequence
OBJECT-TYPE
Turn on or off the test-sequence on link. The operation will take place on the remote MCMESC if it's connected.
1.3.6.1.4.1.4253.1.18.6.1.35FlagTyperead-writemandatory
mcmescConnMuxShelf
OBJECT-TYPE
The connected W4CM/UPSM shelf.
1.3.6.1.4.1.4253.1.18.6.1.36ShelfInputread-onlymandatory
mcmescConnMuxSlot
OBJECT-TYPE
The connected W4CM/UPSM slot.
1.3.6.1.4.1.4253.1.18.6.1.37SlotInputread-onlymandatory
mcmescConnMuxPort
OBJECT-TYPE
The connected W4CM/UPSM port. W4CM: 1=1470/1510, 2=1490/1530, 3=15501590/, 4=1570/1610, 5=EXP, 6=IN/OUT; UPSM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx.
1.3.6.1.4.1.4253.1.18.6.1.38INTEGERread-onlymandatory
mcmescConnDemuxShelf
OBJECT-TYPE
The connected W4CD/UPSM shelf.
1.3.6.1.4.1.4253.1.18.6.1.39ShelfInputread-onlymandatory
mcmescConnDemuxSlot
OBJECT-TYPE
The connected W4CD/UPSM slot.
1.3.6.1.4.1.4253.1.18.6.1.40SlotInputread-onlymandatory
mcmescConnDemuxPort
OBJECT-TYPE
The connected W4CD/UPSM port. W4CD: 1=1470/1510, 2=1490/1530, 3=15501590/, 4=1570/1610, 5=EXP, 6=IN/OUT; UPSM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx.
1.3.6.1.4.1.4253.1.18.6.1.41INTEGERread-onlymandatory
mcmescConnTxOcmShelf
OBJECT-TYPE
The connected OCM shelf (from MCMESC's Link Tx).
1.3.6.1.4.1.4253.1.18.6.1.42ShelfInputread-onlymandatory
mcmescConnTxOcmSlot
OBJECT-TYPE
The connected OCM slot (from MCMESC's Link Tx).
1.3.6.1.4.1.4253.1.18.6.1.43SlotInputread-onlymandatory
mcmescConnTxOcmPort
OBJECT-TYPE
The connected OCM port (from MCMESC's Link Tx). 3=OCM's CPE-Tx, 4=OCM's Rx. Only 4 is valid.
1.3.6.1.4.1.4253.1.18.6.1.44INTEGER {cpetx(3), cperx(4)}read-onlymandatory
mcmescConnTxOcmShelfSlot
OBJECT-TYPE
Add a connection from MCMESC Link-Tx to an OCM CPE-Rx by specifying the OCM's shelf and slot. The format is shlef,slot. If either MCMESC Link-Tx or specified OCM CPE-Rx has already had connection, an error will be returned. If the card specified by shelf,slot is not ocm type, an error will be returned. A get on this variable will always return 0,0.
1.3.6.1.4.1.4253.1.18.6.1.45DisplayString (SIZE(0..10))read-writemandatory
mcmescConnTxOcmDelete
OBJECT-TYPE
Delete a connection from MCMESC Link-Tx to an OCM CPE-Rx. If MCMESC's Link-Tx has no connection with any OCM's CPE-Rx, an error will be returned. A get on this variable will always return an other.
1.3.6.1.4.1.4253.1.18.6.1.46INTEGER {other(1), yes(2)}read-writemandatory
mcmescConnRxOcmShelf
OBJECT-TYPE
The connected OCM shelf (from MCMESC's Link Rx).
1.3.6.1.4.1.4253.1.18.6.1.47ShelfInputread-onlymandatory
mcmescConnRxOcmSlot
OBJECT-TYPE
The connected OCM slot (from MCMESC's Link Rx).
1.3.6.1.4.1.4253.1.18.6.1.48SlotInputread-writemandatory
mcmescConnRxOcmPort
OBJECT-TYPE
The connected OCM port (from MCMESC's Link Rx). 3=OCM's CPE-Tx, 4=OCM's Rx. Only 3 is valid.
1.3.6.1.4.1.4253.1.18.6.1.49INTEGER {cpetx(3), cperx(4)}read-writemandatory
mcmescConnRxOcmShelfSlot
OBJECT-TYPE
Add a connection from MCMESC Link-Rx to an OCM CPE-Tx by specifying the OCM's shelf and slot. The format is shlef,slot. If either MCMESC Link-Tx or specified OCM CPE-Rx has already had connection, an error will be returned. If the card specified by shelf,slot is not ocm type, an error will be returned. A get on this variable will always return 0,0
1.3.6.1.4.1.4253.1.18.6.1.50DisplayString (SIZE(0..10))read-writemandatory
mcmescConnRxOcmDelete
OBJECT-TYPE
Delete a connection from MCMESC Link-Rx to an OCM CPE-Tx. If MCMESC's Link-Rx has no connection with any OCM's CPE-Tx, an error will be returned. A get on this variable will always return an other.
1.3.6.1.4.1.4253.1.18.6.1.51INTEGER {other(1), yes(2)}read-writemandatory
mcmescSetState
OBJECT-TYPE
Instruct the mcmesc card to do either a reset or loopback. A get on this will always return an other. If the card is in self-test, an error will be returned. If the card is already in any loopback, and try to turn on another loopback, an error will be returned.
1.3.6.1.4.1.4253.1.18.6.1.52INTEGER {other(1), resetWithCurrentConfiguration(2), nearEndCardLoopback(3), networkCardLoopback(4), nearEndPort1Loopback(5), nearEndPort2Loopback(6), nearEndPort3Loopback(7), nearEndPort4Loopback(8), nearEndPort5Loopback(9), nearEndPort6Loopback(10), nearEndPort7Loopback(11), nearEndPort8Loopback(12), nearEndPort9Loopback(13), nearEndPort10Loopback(14), nearEndPort11Loopback(15), nearEndPort12Loopback(16), networkPort1Loopback(17), networkPort2Loopback(18), networkPort3Loopback(19), networkPort4Loopback(20), networkPort5Loopback(21), networkPort6Loopback(22), networkPort7Loopback(23), networkPort8Loopback(24), networkPort9Loopback(25), networkPort10Loopback(26), networkPort11Loopback(27), networkPort12Loopback(28), disableLoopback(29)}read-writemandatory
mcmescLinkClrErrCount
OBJECT-TYPE
Instruct the mcmesc card to clear the bit-error count for link port. A get on this will always return an other.
1.3.6.1.4.1.4253.1.18.6.1.53INTEGER {other(1), clearErrCount(2)}read-writemandatory
mcmescPortNumber
OBJECT-TYPE
Number of MCMESC rows in the following table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.18.7INTEGERread-onlymandatory
mcmescPortTable
OBJECT-TYPE
This table represents the information for each MCMESC module's port.
1.3.6.1.4.1.4253.1.18.8not-accessiblemandatory
mcmescPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.18.8.1not-accessiblemandatory
mcmescPortCardLocation
OBJECT-TYPE
Location of the MCMESC port. Valid values are: Local in the same chassis, or remote to this chassis.
1.3.6.1.4.1.4253.1.18.8.1.1CardLocationread-onlymandatory
mcmescPortCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1..2.
1.3.6.1.4.1.4253.1.18.8.1.2CardShelfread-onlymandatory
mcmescPortCardSlot
OBJECT-TYPE
The slot within the shelf the Module is in. Valid values are: 1 to 17.
1.3.6.1.4.1.4253.1.18.8.1.3SlotInputread-onlymandatory
mcmescPortIndex
OBJECT-TYPE
CPE port's index. Valid values are: 1 to 12.
1.3.6.1.4.1.4253.1.18.8.1.4INTEGERread-onlymandatory
mcmescPortSfpSerialNum
OBJECT-TYPE
CPE port's SFP serial number.
1.3.6.1.4.1.4253.1.18.8.1.5SfpSerialStringread-onlymandatory
mcmescPortConnectionState
OBJECT-TYPE
CPE port's connection status.
1.3.6.1.4.1.4253.1.18.8.1.6INTEGER {disabled(1), enabled(2)}read-writemandatory
mcmescPortClrErrCount
OBJECT-TYPE
Instruct the mcmesc card to clear the bit-error count for a CPE port. A get on this will always return an other.
1.3.6.1.4.1.4253.1.18.8.1.7INTEGER {other(1), clearErrCount(2)}read-writemandatory
systemConfig
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.21
sysAddCard
OBJECT-TYPE
Add card operation given type, shelf, slot, and optionally sub card type. The format is (type,shelf, slot[,optional]). If the fourth optional parameter is present, for OCMITU/OCMU, its value should be 1 to indicate OCMITU/OCMU with CSIM; for MCMESC, its value should be 0 or 1 to indicate MPM will not overide or will override the settings stored on MCMESC upon detecting it. Different types of card: OCMU: 2 //with or without csim module OCMI: 3 //with or without csim module OFCM: 4 OFCD: 5 FADM: 6 MCMT1: 8 W4CD: 10 W2CM/D: 13 OSAM: 20 W4CM: 21 RSM: 22 UPSM: 23 OCME: 24 OCM10G: 27 OSAM-LP: 29 OSAM-HP: 30 MCMESC: 33 WFADM: 34 MCME1: 35 MD100-1: 36 MD100-40: 37 TAP: 38 MD100-5 39 MD100-10 40 OCM10GLR 41 BD-4 42 BP-10 43 DMM 45 BP-5 46 OSC 48 OCM2 49 OCM10GF 50 OCM2-4G 51 OET 52 UOB 53 FC8G 54 MD100P 55 CWDM_BD4 56 For example, to add a FADM card in shelf 1, slot 8, this variable will be set to 6,1,8. To add an OCMI card with colorsim module in shelf 1, slot 7, this variable will be set to 3,1,7,1. To add an MCMESC card with override option in shelf 1, slot 7, this variable will be set to 33,1,7,1. A get on this will return 0,0,0,0
1.3.6.1.4.1.4253.1.21.1DisplayString (SIZE(0..10))read-writemandatory
sysAlarmCtrl
OBJECT-TYPE
The Master Control for Alarms. Will enable or disable all external and visual alarms of the system. The default state is enable.
1.3.6.1.4.1.4253.1.21.2INTEGER {enable(1), disable(2)}read-writemandatory
sysAlarmCritical
OBJECT-TYPE
Turns on or off all external critical audible and visual alarms.
1.3.6.1.4.1.4253.1.21.3INTEGER {on(1), off(2)}read-writemandatory
sysAlarmMajor
OBJECT-TYPE
Turns on or off all external major and minor audible and visual alarms.
1.3.6.1.4.1.4253.1.21.4INTEGER {on(1), off(2)}read-writemandatory
sysAlarmSerial
OBJECT-TYPE
Enables or disables the flow of TL1 alarms to the serial port.
1.3.6.1.4.1.4253.1.21.5INTEGER {enable(1), disable(2)}read-writemandatory
sysAlarmAutoCutoff
OBJECT-TYPE
Enables or disables the AutoCutoff feature for dry-contact alarm closures
1.3.6.1.4.1.4253.1.21.6INTEGER {enable(1), disable(2)}read-writemandatory
sysAddRoute
OBJECT-TYPE
Add route operation given local shelf, local slot, destination IP address and route Type. The format is (shelf, slot, route Type, destination IP). Different types of route types are: external Route: 1 (Route to an external non LuxN node) internal Route: 2 (Route to a LuxN node in the network) For example, to add an internal route to a LuxN node with IP address 192.162.6.65 from local shelf 1, slot 6 this variable would be set to 1,6,3,192.162.6.65 For adding an external route, shelf & slot needs to be zero. For e.g To add an external route to destination address 192.168.9.99, this variable needs to be set to 0,0,192.168.9.99 A get on this will return 0,0,0,0 NO LONGER SUPPORTED, user now needs to use sysImnAddRoute
1.3.6.1.4.1.4253.1.21.7DisplayString (SIZE(0..20))not-accessiblemandatory
sysDeleteRoute
OBJECT-TYPE
Delete route operation given local shelf, local slot & destination IP address . The format is (shelf, slot, destination IP). For example, to delete a route to a LuxN node with IP address 192.162.6.65 from local shelf 1, slot 6 this variable would be set to 1,6,192.162.6.65 A get on this will return 0,0,0 NO LONGER SUPPORTED, user now needs to use sysImnAddRoute
1.3.6.1.4.1.4253.1.21.8DisplayString (SIZE(0..20))not-accessiblemandatory
sysSwitchByPathId
OBJECT-TYPE
Initiate UPSR switching by Path ID.
1.3.6.1.4.1.4253.1.21.9PathIdNameread-writemandatory
sysSwitchAll
OBJECT-TYPE
Switch all CC cards that have backup.
1.3.6.1.4.1.4253.1.21.10INTEGER {yes(1), no(2)}read-writemandatory
sysAlarmMinor
OBJECT-TYPE
Turns on or off all external minor audible and visual alarms.
1.3.6.1.4.1.4253.1.21.11INTEGER {on(1), off(2)}read-writemandatory
sysDelCfgDb
OBJECT-TYPE
Action to delete configuration database. MPM would reboot after the database is deleted. A get on it will return other
1.3.6.1.4.1.4253.1.21.12INTEGER {other(1), delete(2)}read-writemandatory
sysImnAddRoute
OBJECT-TYPE
Add route operation. It takes destination IP address, IP mask and the route metric. The format is (destination IP, IP mask, routeMetric). A get on this will return 0.0.0.0,0.0.0.0,0
1.3.6.1.4.1.4253.1.21.13DisplayString (SIZE(0..20))read-writemandatory
sysImnDeleteRoute
OBJECT-TYPE
Delete route operation. It takes destination IP address and IP mask. The format is (destination IP, IP mask=). A get on this will return 0.0.0.0,0.0.0.0
1.3.6.1.4.1.4253.1.21.14DisplayString (SIZE(0..20))read-writemandatory
sysExtAlarmInputTable
OBJECT-TYPE
This table represents the input information for each external alarm indicator
1.3.6.1.4.1.4253.1.21.17not-accessiblemandatory
sysExtAlarmInputEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.21.17.1not-accessiblemandatory
sysExtAlarmInputId
OBJECT-TYPE
Id of an external alarm indicator. Valid values are: 1 to 6
1.3.6.1.4.1.4253.1.21.17.1.1INTEGERread-onlymandatory
sysExtAlarmInput
OBJECT-TYPE
Configurable value for an external alarm indicator. Default value is off. For the chassis with old sensor board, the value is na and is not settable.
1.3.6.1.4.1.4253.1.21.17.1.2INTEGER {off(1), minor(2), major(3), critical(4), na(5)}read-writemandatory
sysExtAlarmInputName
OBJECT-TYPE
User configurable name for an external alarm input indicator. For the chassis with old sensor board, the value is na and is not settable.
1.3.6.1.4.1.4253.1.21.17.1.3AlarmTyperead-writemandatory
sysAudioAlarm
OBJECT-TYPE
Mode for audio alarm. Default is off. For non-carrier-class chassis, it is na
1.3.6.1.4.1.4253.1.21.18INTEGER {brief(1), test(2), continous(3), off(4), na(5)}read-writemandatory
sysAudioAlarmSeverity
OBJECT-TYPE
Controls for audio alarm. When the control is set to minor, it will go off for all minor and up alarms. Default is major. For non-carrier-class chassis, it is na. These control only make sense for audio alarm in brief or continous mode
1.3.6.1.4.1.4253.1.21.19INTEGER {major(1), critical(2), minor(3), na(4)}read-writemandatory
sysRdbcopy
OBJECT-TYPE
Forces a database copy to the standby MPM. Reading this element will always return 'other'. This element can only be set to 'copydb'. If the standby MPM is present then a database copy will be initiated, otherwise an error will be return.
1.3.6.1.4.1.4253.1.21.20INTEGER {other(1), copydb(2)}read-writemandatory
sysRdbcopyStatus
OBJECT-TYPE
Displays the percentage done for forced database copies. No value is returned if a forced database copy is not in progress.
1.3.6.1.4.1.4253.1.21.21INTEGERread-onlymandatory
sysSDMRequestsQueued
OBJECT-TYPE
Displays the number of requests in the SDM queue.
1.3.6.1.4.1.4253.1.21.22INTEGERread-onlymandatory
sysModuleupdateJobsWaiting
OBJECT-TYPE
Displays the number of module updates jobs from the current request that must wait until one or more of the jobs progressing completes. This element will only be returned if one or more module update jobs are in progress.
1.3.6.1.4.1.4253.1.21.23INTEGERread-onlymandatory
sysModuleupdateJobsTable
OBJECT-TYPE
This table defines the module update jobs in progress. Table entries will only be reutrned if one for more module update jobs are in progress.
1.3.6.1.4.1.4253.1.21.24not-accessiblemandatory
sysModuleupdateJobsEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.21.24.1not-accessiblemandatory
sysModupdShelf
OBJECT-TYPE
Shelf of the module being updated. For remote updates this will be the shelf of the local module through the update occurs.
1.3.6.1.4.1.4253.1.21.24.1.1INTEGERread-onlymandatory
sysModupdSlot
OBJECT-TYPE
Slot of the module being updated. For remote updates this will be the slot of the local module through the update occurs.
1.3.6.1.4.1.4253.1.21.24.1.2INTEGERread-onlymandatory
sysModupdLocation
OBJECT-TYPE
Location (local or remote) of the module being updated
1.3.6.1.4.1.4253.1.21.24.1.3CardLocationread-onlymandatory
sysModupdRmtStation
OBJECT-TYPE
Remote station of the module being updated
1.3.6.1.4.1.4253.1.21.24.1.4INTEGERread-onlymandatory
sysModupdCardtype
OBJECT-TYPE
Type of module being updated.
1.3.6.1.4.1.4253.1.21.24.1.5CardTyperead-onlymandatory
sysModupdPercentDone
OBJECT-TYPE
Percentage of update completed.
1.3.6.1.4.1.4253.1.21.24.1.6INTEGERread-onlymandatory
sysSNMPKeepaliveEnable
OBJECT-TYPE
Enable or disable SNMP keep alive functionality.
1.3.6.1.4.1.4253.1.21.25INTEGER {enabled(1), disabled(2)}read-writemandatory
sysSNMPKeepaliveInterval
OBJECT-TYPE
Set the SNMP keep alive interval in minutes.
1.3.6.1.4.1.4253.1.21.26INTEGER (1..1440)read-writemandatory
topology
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.22
topologyTable
OBJECT-TYPE
This table represents the link topology between local and remote cards
1.3.6.1.4.1.4253.1.22.1not-accessiblemandatory
topologyEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.22.1.1not-accessiblemandatory
topologyNearEndCardShelf
OBJECT-TYPE
Shelf of the near end card.
1.3.6.1.4.1.4253.1.22.1.1.1CardShelfread-onlymandatory
topologyNearEndCardSlot
OBJECT-TYPE
Slot of the near end card. Input 0 will delete the topology link.
1.3.6.1.4.1.4253.1.22.1.1.2CardSlotread-writemandatory
topologyNearEndCardPortIndex
OBJECT-TYPE
Near end optical link port.
1.3.6.1.4.1.4253.1.22.1.1.3PortIndexread-onlymandatory
topologyNearEndCardType
OBJECT-TYPE
Card type of the near end card.
1.3.6.1.4.1.4253.1.22.1.1.4CardTyperead-onlymandatory
topologyFarEndChassisID
OBJECT-TYPE
Chassis ID of the far end chassis. Part of manufacturing info
1.3.6.1.4.1.4253.1.22.1.1.5NodeNameread-onlymandatory
topologyFarEndSystemName
OBJECT-TYPE
Name of the far end node/chassis. Not supported for remote TMM masters.
1.3.6.1.4.1.4253.1.22.1.1.6NodeNameread-onlymandatory
topologyFarEndNodeIpAddress
OBJECT-TYPE
IpAddress of the far end chassis. Not supported for remote TMM masters.
1.3.6.1.4.1.4253.1.22.1.1.7IpAddressread-onlymandatory
topologyFarEndNodeCardShelf
OBJECT-TYPE
Shelf of the far end module
1.3.6.1.4.1.4253.1.22.1.1.8CardShelfread-onlymandatory
topologyFarEndNodeCardSlot
OBJECT-TYPE
Slot of the far end module
1.3.6.1.4.1.4253.1.22.1.1.9CardSlotread-onlymandatory
topologyFarEndNodeCardPortIndex
OBJECT-TYPE
Far end optical link port.
1.3.6.1.4.1.4253.1.22.1.1.10PortIndexread-onlymandatory
topologyLinkStatus
OBJECT-TYPE
Status of the link to indicate if active or down
1.3.6.1.4.1.4253.1.22.1.1.11INTEGER {down(1), active(2), standby(3)}read-onlymandatory
topologyFarEndNodeCardType
OBJECT-TYPE
Card type of the far end card.
1.3.6.1.4.1.4253.1.22.1.1.12CardTyperead-onlymandatory
topologyDiscover
OBJECT-TYPE
An action to rediscover the complete topology A get would alway return other(1).
1.3.6.1.4.1.4253.1.22.2INTEGER {other(1), discoverTopology(2)}read-writemandatory
routing
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.23
routingTable
OBJECT-TYPE
This table represents dynamic and static routing information
1.3.6.1.4.1.4253.1.23.1not-accessiblemandatory
routingEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.23.1.1not-accessiblemandatory
routeLocalCCShelf
OBJECT-TYPE
Shelf of the local CC card.
1.3.6.1.4.1.4253.1.23.1.1.1CardShelfnot-accessiblemandatory
routeLocalCCSlot
OBJECT-TYPE
Slot of the local CC card.
1.3.6.1.4.1.4253.1.23.1.1.2CardSlotnot-accessiblemandatory
routeIpDestAddress
OBJECT-TYPE
Destination IP address. Not supported for remote TMM masters.
1.3.6.1.4.1.4253.1.23.1.1.3IpAddressnot-accessiblemandatory
routeDestType
OBJECT-TYPE
Destination route type. External means destination is not part of LuxN network. Internal means destination is one of the LuxN node
1.3.6.1.4.1.4253.1.23.1.1.4INTEGER {externalRoute(1), internalRoute(2)}not-accessiblemandatory
routeMode
OBJECT-TYPE
Is the route added statically(manually) or dynamically(automatic)
1.3.6.1.4.1.4253.1.23.1.1.5INTEGER {static(1), dynamic(2)}not-accessiblemandatory
imnDynamicRoutingTable
OBJECT-TYPE
This table represents IMN based dynamic routing information
1.3.6.1.4.1.4253.1.23.2not-accessiblemandatory
imnDynamicRoutingEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.23.2.1not-accessiblemandatory
imnDynamicRouteIpDest
OBJECT-TYPE
Destination IP address. Not supported for remote TMM masters.
1.3.6.1.4.1.4253.1.23.2.1.1IpAddressread-onlymandatory
imnDynamicRouteIpMask
OBJECT-TYPE
Destination's IP mask address. Not supported for remote TMM masters.
1.3.6.1.4.1.4253.1.23.2.1.2IpAddressread-onlymandatory
imnDynamicRouteMetric
OBJECT-TYPE
Cost associated with this route.
1.3.6.1.4.1.4253.1.23.2.1.3INTEGER (1..15)read-onlymandatory
imnDynamicRouteNextHop
OBJECT-TYPE
Neighbour node of this route.
1.3.6.1.4.1.4253.1.23.2.1.4IpAddressread-onlymandatory
imnDynamicRouteSysName
OBJECT-TYPE
Destination system name associated with route.
1.3.6.1.4.1.4253.1.23.2.1.5DisplayString (SIZE(0..20))read-onlymandatory
imnRouteUpdateTimer
OBJECT-TYPE
Time in seconds for the route table to get updated/propagated Default value is 30 seconds.
1.3.6.1.4.1.4253.1.23.3INTEGER (1..254)read-writemandatory
imnRouteKeepAliveTimer
OBJECT-TYPE
Time in seconds before neighbors enter unreachable state after communication is lost. This value has to be greater than or equal to imnRouteUpdateTimer Default value is 60 seconds
1.3.6.1.4.1.4253.1.23.4INTEGER (1..255)read-writemandatory
imnRouteUnReachableTimer
OBJECT-TYPE
Time in seconds before Neighbors in unreachable state are deleted from the route table. This value has to greater than or equal to imnRouteUpdateTimer Default value is 60 seconds
1.3.6.1.4.1.4253.1.23.5INTEGER (1..255)read-writemandatory
imnRouteMode
OBJECT-TYPE
Enable/Disable IMN functionality. Default is disabled
1.3.6.1.4.1.4253.1.23.6INTEGER {disabled(1), enable(2)}read-writemandatory
imnStaticRoutingTable
OBJECT-TYPE
This table represents IMN based static routing information
1.3.6.1.4.1.4253.1.23.7not-accessiblemandatory
imnStaticRoutingEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.23.7.1not-accessiblemandatory
imnStaticRouteIpDest
OBJECT-TYPE
Destination IP address. Not supported for remote TMM masters.
1.3.6.1.4.1.4253.1.23.7.1.1IpAddressread-onlymandatory
imnStaticRouteIpMask
OBJECT-TYPE
Destination's IP mask address. Not supported for remote TMM masters.
1.3.6.1.4.1.4253.1.23.7.1.2IpAddressread-onlymandatory
imnStaticRouteMetric
OBJECT-TYPE
Cost associated with this route.
1.3.6.1.4.1.4253.1.23.7.1.3INTEGER (1..15)read-onlymandatory
imnRouteMaxMetric
OBJECT-TYPE
Maximum acceptable metric count before the routes gets dropped. Default value is 255. Ideally this value should be greater than imnStaticRouteMetric
1.3.6.1.4.1.4253.1.23.8INTEGERread-writemandatory
ring
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.24
ringNum
OBJECT-TYPE
Total number of ring configured in the list.
1.3.6.1.4.1.4253.1.24.1INTEGERread-onlymandatory
ringTable
OBJECT-TYPE
This table represent the ring information
1.3.6.1.4.1.4253.1.24.2not-accessiblemandatory
ringEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.24.2.1not-accessiblemandatory
ringIndex
OBJECT-TYPE
The ringIndex and also the index of the ring table.
1.3.6.1.4.1.4253.1.24.2.1.1INTEGERnot-accessiblemandatory
ringID
OBJECT-TYPE
RingID Name for UPSR. Empty string will remove and deassociate the RingID with the PathIDs. You always has one dummy entry for adding another ring.
1.3.6.1.4.1.4253.1.24.2.1.2RingIdNameread-writemandatory
ringPathID1
OBJECT-TYPE
PathID 1 associate with this ring.
1.3.6.1.4.1.4253.1.24.2.1.3PathIdNameread-writemandatory
ringPathID2
OBJECT-TYPE
PathID 2 associate with this ring.
1.3.6.1.4.1.4253.1.24.2.1.4PathIdNameread-writemandatory
ringPath1RemoteIP
OBJECT-TYPE
IP Address of the neighbor node associated with path 1
1.3.6.1.4.1.4253.1.24.2.1.5IpAddressread-onlymandatory
ringPath1RemoteChassisId
OBJECT-TYPE
Chassis ID of the neighbor node associated with path 1
1.3.6.1.4.1.4253.1.24.2.1.6DisplayString (SIZE(0..16))read-onlymandatory
ringPath2RemoteIP
OBJECT-TYPE
IP Address of the neighbor node associated with path 2
1.3.6.1.4.1.4253.1.24.2.1.7IpAddressread-onlymandatory
ringPath2RemoteChassisId
OBJECT-TYPE
Chassis ID of the neighbor node associated with path 2
1.3.6.1.4.1.4253.1.24.2.1.8DisplayString (SIZE(0..16))read-onlymandatory
tap
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.25
tapNumber
OBJECT-TYPE
Number of TAP rows in the following table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.25.1INTEGERread-onlymandatory
tapTable
OBJECT-TYPE
This table represents the information for each TAP module
1.3.6.1.4.1.4253.1.25.2not-accessiblemandatory
tapEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.25.2.1not-accessiblemandatory
tapCardLocation
OBJECT-TYPE
Location of the module. Valid values are: Local in the same chassis, or remote to this chassis
1.3.6.1.4.1.4253.1.25.2.1.1CardLocationread-onlymandatory
tapCardShelf
OBJECT-TYPE
The shelf the card is in.
1.3.6.1.4.1.4253.1.25.2.1.2CardShelfread-onlymandatory
tapCardSlot
OBJECT-TYPE
The slot within the shelf the module is in. The range of valid values range from 1 through 17 depending on the chassis type and the shelf the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.25.2.1.3SlotInputread-writemandatory
tapModelNum
OBJECT-TYPE
Model number for module.
1.3.6.1.4.1.4253.1.25.2.1.4DisplayStringread-onlymandatory
tapMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the module
1.3.6.1.4.1.4253.1.25.2.1.5DateAndTimenot-accessiblemandatory
tapSerialNum
OBJECT-TYPE
Serial number of the module.
1.3.6.1.4.1.4253.1.25.2.1.6SerialStringread-onlymandatory
tapModelType
OBJECT-TYPE
Model type of the module
1.3.6.1.4.1.4253.1.25.2.1.7CardTyperead-onlymandatory
tapName
OBJECT-TYPE
User configurable name of the module
1.3.6.1.4.1.4253.1.25.2.1.8CardNameread-writemandatory
tapFWVersionID
OBJECT-TYPE
The current version string of the FW code
1.3.6.1.4.1.4253.1.25.2.1.9VersionStringread-onlymandatory
tapHWName
OBJECT-TYPE
Display Hardware name of the module.
1.3.6.1.4.1.4253.1.25.2.1.10CardNameread-onlymandatory
tapPathID
OBJECT-TYPE
Upsr Path ID name that this card is associated with. Set input equal NULL will remove the card off the path and also remove the path if there is no card left associate with that path.
1.3.6.1.4.1.4253.1.25.2.1.11PathIdNameread-writemandatory
tapAdminState
OBJECT-TYPE
Administrative control over that TAP card. Default value is enable. When disabled, no alarms/events gets generated.
1.3.6.1.4.1.4253.1.25.2.1.12INTEGER {disable(1), enable(2), na(3)}read-writemandatory
tapCleiNum
OBJECT-TYPE
CLEI number for the module.
1.3.6.1.4.1.4253.1.25.2.1.13DisplayStringread-onlymandatory
tapNumPorts
OBJECT-TYPE
Total port numbers on each TAP card.
1.3.6.1.4.1.4253.1.25.2.1.14INTEGERread-onlymandatory
voadm
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.26
voadmNumber
OBJECT-TYPE
Number of rows in the voadm table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.26.1INTEGERread-onlymandatory
voadmTable
OBJECT-TYPE
This table represents the information for each VOADM card
1.3.6.1.4.1.4253.1.26.2not-accessiblemandatory
voadmEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.26.2.1not-accessiblemandatory
voadmCardLocation
OBJECT-TYPE
Location of the module. VOADM modules will always be seen as local modules.
1.3.6.1.4.1.4253.1.26.2.1.1CardLocationread-onlymandatory
voadmCardShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.26.2.1.2CardShelfread-onlymandatory
voadmCardSlot
OBJECT-TYPE
The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.26.2.1.3SlotInputread-writemandatory
voadmSerialNum
OBJECT-TYPE
Module serial number.
1.3.6.1.4.1.4253.1.26.2.1.4SerialStringread-onlymandatory
voadmModelNum
OBJECT-TYPE
Module model number.
1.3.6.1.4.1.4253.1.26.2.1.5DisplayStringread-onlymandatory
voadmHwName
OBJECT-TYPE
Module hardware name.
1.3.6.1.4.1.4253.1.26.2.1.6DisplayStringread-onlymandatory
voadmHwVersionID
OBJECT-TYPE
Module hardware version.
1.3.6.1.4.1.4253.1.26.2.1.7VersionStringread-onlymandatory
voadmMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the module
1.3.6.1.4.1.4253.1.26.2.1.8DateAndTimeread-onlymandatory
voadmFwName
OBJECT-TYPE
Module firmware name.
1.3.6.1.4.1.4253.1.26.2.1.9CardNameread-onlymandatory
voadmFwVersionID
OBJECT-TYPE
Firmware version.
1.3.6.1.4.1.4253.1.26.2.1.10VersionStringread-onlymandatory
voadmFwDate
OBJECT-TYPE
Firmware release date and time.
1.3.6.1.4.1.4253.1.26.2.1.11DateAndTimeread-onlymandatory
voadmAdminState
OBJECT-TYPE
Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.
1.3.6.1.4.1.4253.1.26.2.1.12INTEGER {disable(1), enable(2), na(3)}read-writemandatory
voadmModelType
OBJECT-TYPE
Model type of the module.
1.3.6.1.4.1.4253.1.26.2.1.13CardTyperead-onlymandatory
voadmName
OBJECT-TYPE
User configurable name of the module.
1.3.6.1.4.1.4253.1.26.2.1.14CardNameread-writemandatory
voadmSetState
OBJECT-TYPE
Instruct the module to do a warmboot. A get on this will always return 'other'.
1.3.6.1.4.1.4253.1.26.2.1.15RebootTyperead-writemandatory
voadmPathID
OBJECT-TYPE
Path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path.
1.3.6.1.4.1.4253.1.26.2.1.16PathIdNameread-writemandatory
voadmCleiNum
OBJECT-TYPE
CLEI number of the module.
1.3.6.1.4.1.4253.1.26.2.1.17DisplayStringread-onlymandatory
voadmActiveChannels
OBJECT-TYPE
Number of active channels connected to the module. The allowed inpu range depends on the module type: MD100-5 1 to 5 MD100-10 1 to 10
1.3.6.1.4.1.4253.1.26.2.1.18INTEGERread-writemandatory
voadmStartItu
OBJECT-TYPE
First ITU channel supported by the module.
1.3.6.1.4.1.4253.1.26.2.1.19INTEGERread-onlymandatory
voadmEndItu
OBJECT-TYPE
Last ITU channel supported by the module.
1.3.6.1.4.1.4253.1.26.2.1.20INTEGERread-onlymandatory
voadmNumPorts
OBJECT-TYPE
Total port numbers on each VOADM card.
1.3.6.1.4.1.4253.1.26.2.1.21INTEGERread-onlymandatory
voadmPortTable
OBJECT-TYPE
This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
1.3.6.1.4.1.4253.1.26.3not-accessiblemandatory
voadmPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.26.3.1not-accessiblemandatory
voadmPortCardLocation
OBJECT-TYPE
Location of the module. VOADM modules will always be seen as local modules.
1.3.6.1.4.1.4253.1.26.3.1.1CardLocationread-onlymandatory
voadmPortCardShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.26.3.1.2CardShelfread-onlymandatory
voadmPortCardSlot
OBJECT-TYPE
The slot within the shelf where the module resides.
1.3.6.1.4.1.4253.1.26.3.1.3SlotInputread-onlymandatory
voadmPortType
OBJECT-TYPE
Port type for which the below values apply.
1.3.6.1.4.1.4253.1.26.3.1.4INTEGER {mux(1), demux(2)}read-onlymandatory
voadmPortMode
OBJECT-TYPE
Port mode. This value will not be stored in the database until the port set point is set.
1.3.6.1.4.1.4253.1.26.3.1.5INTEGER {fixed-attentuation(1), fixed-power(2)}read-writemandatory
voadmPortSetPoint
OBJECT-TYPE
Port set point. Valid range depends on the port mode: Fixed Attentuation 0.0 to 20.0 (dB) Fixed Power -30.0 to 15.0 (dBm) Untils are omitted when setting.
1.3.6.1.4.1.4253.1.26.3.1.6DisplayStringread-writemandatory
voadmPortMinChanInputPower
OBJECT-TYPE
Minimum input power for each active channel. Valid range for Mux and Demux ports is -30.0 to 15.0 dBm
1.3.6.1.4.1.4253.1.26.3.1.7DisplayStringread-writemandatory
voadmPortMinChanOutputPower
OBJECT-TYPE
Minimum output power for each active channel. Valid range depends on port: Mux -20.0 to 15.0 dBm Demux -30.0 to -8.0 dBm.
1.3.6.1.4.1.4253.1.26.3.1.8DisplayStringread-writemandatory
voadmPortMaxChanOutputPower
OBJECT-TYPE
Maximum output power for each active channel. Valid range depends on port: Mux -20.0 to 15.0 dBm Demux -30.0 to -8.0 dBm.
1.3.6.1.4.1.4253.1.26.3.1.9DisplayStringread-writemandatory
voadmPortToleranceUpperBound
OBJECT-TYPE
Upper bound for allowable power/attenuation error. Valid range is 0.2 to 10.0 dB.
1.3.6.1.4.1.4253.1.26.3.1.10DisplayStringread-writemandatory
voadmPortToleranceLowerBound
OBJECT-TYPE
Lower bound for allowable power/attenuation error. Valid range is 0.2 to 10.0 dB.
1.3.6.1.4.1.4253.1.26.3.1.11DisplayStringread-writemandatory
voadmPortTotalInputPower
OBJECT-TYPE
Power reading from input detector. Valid range: -30 to 15 dBm
1.3.6.1.4.1.4253.1.26.3.1.12DisplayStringread-onlymandatory
voadmPortPerChanInputPower
OBJECT-TYPE
Total input power divided by number of active channels. Valid range: -30 to 15 dBm
1.3.6.1.4.1.4253.1.26.3.1.13DisplayStringread-onlymandatory
voadmPortTotalOutputPower
OBJECT-TYPE
Power reading from output detector. Valid range: -30 to 15 dBm
1.3.6.1.4.1.4253.1.26.3.1.14DisplayStringread-onlymandatory
voadmPortPerChanOutputPower
OBJECT-TYPE
Total output power divided by number of active channels. Valid range: -30 to 15 dBm
1.3.6.1.4.1.4253.1.26.3.1.15DisplayStringread-onlymandatory
voadmPortMeasuredAtten
OBJECT-TYPE
Difference between total input power and total output power.
1.3.6.1.4.1.4253.1.26.3.1.16DisplayStringread-onlymandatory
voadmPortAvgInsertLoss
OBJECT-TYPE
Average insertion loss for ports.
1.3.6.1.4.1.4253.1.26.3.1.17DisplayStringread-onlymandatory
voadmPortAvgExpressLoss
OBJECT-TYPE
Average express los for ports.
1.3.6.1.4.1.4253.1.26.3.1.18DisplayStringread-onlymandatory
zmsConfigSync
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.27
zmsConfigSyncExists
OBJECT-TYPE
Indicates whether or not there exists records to be sent to the ZMS config synch manager for changes that have been made by CLI/HTTP to the data base.
1.3.6.1.4.1.4253.1.27.1Booleanread-onlycurrent
zmsConfigSyncOverflow
OBJECT-TYPE
Indicates whether or not the device had to discard update data base records due to resource constraints. If TRUE, traps will be sent to the ZMS Config Synch Manager indicating a download of the entire data base is required.
1.3.6.1.4.1.4253.1.27.2Booleanread-onlycurrent
zmsConfigSyncPriority
OBJECT-TYPE
Indicates the highest priority configuration synchronization trap outstanding. This flag is set to none at boot time and whenever a file of synchronization changes has been sent to ZMS. If a parameter change has been made to either the same or lower prioirty, the device does not have to send a change notification to ZMS. Higher priority fields must immediately cause traps to be sent to ZMS.
1.3.6.1.4.1.4253.1.27.3INTEGER {none(1), low(2), medium(3), high(4)}read-onlycurrent
zmsConfigSyncAction
OBJECT-TYPE
Used by ZMS when it wants to create a list of config synch records. It must first write the filename expected and then set the action. The create list action allows the device to determine whether the complete database (synchoverflow occured) needs to be sent or only those records that have been modified. create full list specifies that ZMS would like to receive the complete database.
1.3.6.1.4.1.4253.1.27.4INTEGER {noAction(1), createList(2), createFullList(3), createFullListWithAlarms(4), createAlarmsList(5)}read-writecurrent
zmsConfigSyncFileName
OBJECT-TYPE
File Name to be used when creating the config synch records.
1.3.6.1.4.1.4253.1.27.5ZmsFileNameread-writecurrent
zmsConfigSyncStatus
OBJECT-TYPE
Used by Config Sync Acgent when processing a request to create a list of config synch records.
1.3.6.1.4.1.4253.1.27.6INTEGER {syncComplete(1), syncPending(2), syncError(3), syncInitializing(4)}read-onlycurrent
zmsConfigSyncUserName
OBJECT-TYPE
User Name to be used when sending the config synch records. When read, the last user name is returned.
1.3.6.1.4.1.4253.1.27.7ZmsAdminStringread-writecurrent
zmsConfigSyncUserPassword
OBJECT-TYPE
Password to be used when sending the config synch records. For use in FTP authentication. When read, always returns the NULL string
1.3.6.1.4.1.4253.1.27.8ZmsAdminStringread-writecurrent
zmsIpAddress
OBJECT-TYPE
This is the ZMS IP address for which configuration synchronization messages and any other special handling is performed.
1.3.6.1.4.1.4253.1.27.9IpAddressread-writecurrent
dmm
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.28
dmmNumber
OBJECT-TYPE
Number of rows in the dmm table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.28.1INTEGERread-onlymandatory
dmmTable
OBJECT-TYPE
This table represents the information for each DMM card
1.3.6.1.4.1.4253.1.28.2not-accessiblemandatory
dmmEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.28.2.1not-accessiblemandatory
dmmCardLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.28.2.1.1CardLocationread-onlymandatory
dmmCardShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.28.2.1.2CardShelfread-onlymandatory
dmmCardSlot
OBJECT-TYPE
The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.28.2.1.3SlotInputread-writemandatory
dmmSerialNum
OBJECT-TYPE
Module serial number.
1.3.6.1.4.1.4253.1.28.2.1.4SerialStringread-onlymandatory
dmmModelNum
OBJECT-TYPE
Module model number.
1.3.6.1.4.1.4253.1.28.2.1.5DisplayStringread-onlymandatory
dmmHwName
OBJECT-TYPE
Module hardware name.
1.3.6.1.4.1.4253.1.28.2.1.6DisplayStringread-onlymandatory
dmmHwVersionID
OBJECT-TYPE
Module hardware version.
1.3.6.1.4.1.4253.1.28.2.1.7VersionStringread-onlymandatory
dmmMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the module
1.3.6.1.4.1.4253.1.28.2.1.8DateAndTimeread-onlymandatory
dmmFwName
OBJECT-TYPE
Module firmware name.
1.3.6.1.4.1.4253.1.28.2.1.9CardNameread-onlymandatory
dmmFwVersionID
OBJECT-TYPE
Firmware version.
1.3.6.1.4.1.4253.1.28.2.1.10VersionStringread-onlymandatory
dmmFwDate
OBJECT-TYPE
Firmware release date and time.
1.3.6.1.4.1.4253.1.28.2.1.11DateAndTimeread-onlymandatory
dmmAdminState
OBJECT-TYPE
Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.
1.3.6.1.4.1.4253.1.28.2.1.12INTEGER {disable(1), enable(2), na(3)}read-writemandatory
dmmModelType
OBJECT-TYPE
Model type of the module.
1.3.6.1.4.1.4253.1.28.2.1.13CardTyperead-onlymandatory
dmmName
OBJECT-TYPE
User configurable name of the module.
1.3.6.1.4.1.4253.1.28.2.1.14CardNameread-writemandatory
dmmSetState
OBJECT-TYPE
Instruct the module to do a warmboot. A get on this will always return 'other'.
1.3.6.1.4.1.4253.1.28.2.1.15INTEGER {other(1), warmboot(2), enableLinkLoopback(3), enablePort1Loopback(4), enablePort2Loopback(5), disableloopback(6)}read-writemandatory
dmmPathID
OBJECT-TYPE
Path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path.
1.3.6.1.4.1.4253.1.28.2.1.16PathIdNameread-writemandatory
dmmLinkName
OBJECT-TYPE
Link name for fiber between the local and the remote card.
1.3.6.1.4.1.4253.1.28.2.1.17LinkNameread-writemandatory
dmmCleiNum
OBJECT-TYPE
CLEI number of the module.
1.3.6.1.4.1.4253.1.28.2.1.18DisplayStringread-onlymandatory
dmmNumPorts
OBJECT-TYPE
Total port numbers on each DMM card.
1.3.6.1.4.1.4253.1.28.2.1.19INTEGERread-onlymandatory
dmmFpgaRev
OBJECT-TYPE
FPGA revision for the module.
1.3.6.1.4.1.4253.1.28.2.1.20INTEGERread-onlymandatory
dmmPortTable
OBJECT-TYPE
This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
1.3.6.1.4.1.4253.1.28.3not-accessiblemandatory
dmmPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.28.3.1not-accessiblemandatory
dmmPortLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.28.3.1.1CardLocationread-onlymandatory
dmmPortShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.28.3.1.2CardShelfread-onlymandatory
dmmPortSlot
OBJECT-TYPE
The slot within the shelf where the module resides.
1.3.6.1.4.1.4253.1.28.3.1.3SlotInputread-onlymandatory
dmmPortIndex
OBJECT-TYPE
Port for which the below values apply.
1.3.6.1.4.1.4253.1.28.3.1.4INTEGER {link(1), port1(2), port2(3)}read-onlymandatory
dmmPortLineRate
OBJECT-TYPE
Port line rate. Valid only for ports 1 and 2.
1.3.6.1.4.1.4253.1.28.3.1.5INTEGER {notapplicable(0), gbEthernet(4), fibreChannel(5), disabled(255)}read-writemandatory
dmmPortAutoDisable
OBJECT-TYPE
Flag to enable/disable the CPE link when a fault is detected. Far end CPE disable is identical to normal CPE disable with the added feature that the local CPE Tx will be disabled if a loss of light condition is detected on the remote CPE Rx.
1.3.6.1.4.1.4253.1.28.3.1.6INTEGER {notapplicable(0), enable(1), disable(2), farEndEnable(3)}read-writemandatory
dmmPortMode
OBJECT-TYPE
Port mode.
1.3.6.1.4.1.4253.1.28.3.1.7INTEGER {disabled(1), enabled(2), loopback(3)}read-onlymandatory
dmmPortItu
OBJECT-TYPE
Port ITU number. The ITU number is determined from the SFP wavelength.
1.3.6.1.4.1.4253.1.28.3.1.8INTEGERread-onlymandatory
dmmPortWavelength
OBJECT-TYPE
Wavelength from port SFP.
1.3.6.1.4.1.4253.1.28.3.1.9DisplayStringread-onlymandatory
dmmPortRxPower
OBJECT-TYPE
Receive power reported by port SFP.
1.3.6.1.4.1.4253.1.28.3.1.10DisplayStringread-onlymandatory
dmmPortTxState
OBJECT-TYPE
State of port SFP transmitter.
1.3.6.1.4.1.4253.1.28.3.1.11INTEGER {on(1), off(2)}read-onlymandatory
dmmPortTxReach
OBJECT-TYPE
Optical reach in meters reported by port SFP.
1.3.6.1.4.1.4253.1.28.3.1.12INTEGERread-onlymandatory
dmmPortSfpSerialNumber
OBJECT-TYPE
Port SFP serial number.
1.3.6.1.4.1.4253.1.28.3.1.13DisplayStringread-onlymandatory
dmmPortSfpConnectorType
OBJECT-TYPE
Port SFP connector type.
1.3.6.1.4.1.4253.1.28.3.1.14INTEGER {na(0), unknown(1), sc(2), fc_copper1(3), fc_capper2(4), bnc(5), fc_coaxial(6), fiberjack(7), lc(8), mtrj(9), mu(10), sg(11), optpigtail(12), hssdcii(33), copper(34)}read-onlymandatory
dmmConnTable
OBJECT-TYPE
This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
1.3.6.1.4.1.4253.1.28.4not-accessiblemandatory
dmmConnEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.28.4.1not-accessiblemandatory
dmmConnCardLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.28.4.1.1CardLocationread-onlymandatory
dmmConnCardShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.28.4.1.2CardShelfread-onlymandatory
dmmConnCardSlot
OBJECT-TYPE
The slot within the shelf where the module resides.
1.3.6.1.4.1.4253.1.28.4.1.3SlotInputread-onlymandatory
dmmConnCardPortType
OBJECT-TYPE
Port for which the below values apply.
1.3.6.1.4.1.4253.1.28.4.1.4INTEGER {port1tx(1), port1rx(2), port2tx(3), port2rx(4), linktx(5), linkrx(6)}read-onlymandatory
dmmConnCardType
OBJECT-TYPE
Module type connected to port.
1.3.6.1.4.1.4253.1.28.4.1.5CardTyperead-onlymandatory
dmmConnLocation
OBJECT-TYPE
The chassis location of the card connected to this port.
1.3.6.1.4.1.4253.1.28.4.1.6CardLocationread-onlymandatory
dmmConnShelf
OBJECT-TYPE
The shelf of the card connected to this port
1.3.6.1.4.1.4253.1.28.4.1.7ShelfInputread-onlymandatory
dmmConnSlot
OBJECT-TYPE
The slot of the card connected to this port
1.3.6.1.4.1.4253.1.28.4.1.8SlotInputread-onlymandatory
dmmConnPort
OBJECT-TYPE
Conn port for the DMM's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. Entry supported by all Mux modules except MD100-40 & BD4.
1.3.6.1.4.1.4253.1.28.4.1.9INTEGERread-onlymandatory
ocm10gf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.29
ocm10gfNumber
OBJECT-TYPE
Number of rows in the ocm10gf table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.29.1INTEGERread-onlymandatory
ocm10gfTable
OBJECT-TYPE
This table represents the information for each OCM10GF card
1.3.6.1.4.1.4253.1.29.2not-accessiblemandatory
ocm10gfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.29.2.1not-accessiblemandatory
ocm10gfCardLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.29.2.1.1CardLocationread-onlymandatory
ocm10gfCardShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.29.2.1.2CardShelfread-onlymandatory
ocm10gfCardSlot
OBJECT-TYPE
The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.29.2.1.3SlotInputread-writemandatory
ocm10gfSerialNum
OBJECT-TYPE
Module serial number.
1.3.6.1.4.1.4253.1.29.2.1.4SerialStringread-onlymandatory
ocm10gfModelNum
OBJECT-TYPE
Module model number.
1.3.6.1.4.1.4253.1.29.2.1.5DisplayStringread-onlymandatory
ocm10gfHwName
OBJECT-TYPE
Module hardware name.
1.3.6.1.4.1.4253.1.29.2.1.6DisplayStringread-onlymandatory
ocm10gfHwVersionID
OBJECT-TYPE
Module hardware version.
1.3.6.1.4.1.4253.1.29.2.1.7VersionStringread-onlymandatory
ocm10gfMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the module
1.3.6.1.4.1.4253.1.29.2.1.8DateAndTimeread-onlymandatory
ocm10gfFwName
OBJECT-TYPE
Module firmware name.
1.3.6.1.4.1.4253.1.29.2.1.9CardNameread-onlymandatory
ocm10gfFwVersionID
OBJECT-TYPE
Firmware version.
1.3.6.1.4.1.4253.1.29.2.1.10VersionStringread-onlymandatory
ocm10gfFwDate
OBJECT-TYPE
Firmware release date and time.
1.3.6.1.4.1.4253.1.29.2.1.11DateAndTimeread-onlymandatory
ocm10gfModelType
OBJECT-TYPE
Model type of the module.
1.3.6.1.4.1.4253.1.29.2.1.12CardTyperead-onlymandatory
ocm10gfName
OBJECT-TYPE
User configurable name of the module.
1.3.6.1.4.1.4253.1.29.2.1.13CardNameread-writemandatory
ocm10gfLineRate
OBJECT-TYPE
Port line rate. Valid only for ports 1 and 2.
1.3.6.1.4.1.4253.1.29.2.1.14INTEGER {gbE10(9), fc10(11), oc192nt(12), oc192tr(13), disabled(255)}read-writemandatory
ocm10gfAutoDisable
OBJECT-TYPE
Flag to enable/disable the CPE link when a fault is detected. Far end CPE disable is identical to normal CPE disable with the added feature that the local CPE Tx will be disabled if a loss of light condition is detected on the remote CPE Rx.
1.3.6.1.4.1.4253.1.29.2.1.15INTEGER {enable(1), disable(2)}read-writemandatory
ocm10gfLinkName
OBJECT-TYPE
Link name for fiber between the local and the remote card.
1.3.6.1.4.1.4253.1.29.2.1.16LinkNameread-writemandatory
ocm10gfPathID
OBJECT-TYPE
Path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path.
1.3.6.1.4.1.4253.1.29.2.1.17PathIdNameread-writemandatory
ocm10gfAdminState
OBJECT-TYPE
Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.
1.3.6.1.4.1.4253.1.29.2.1.18INTEGER {disable(1), enable(2), na(3)}read-writemandatory
ocm10gfSetState
OBJECT-TYPE
Instruct the module to do a warmboot. A get on this will always return 'other'.
1.3.6.1.4.1.4253.1.29.2.1.19INTEGER {other(1), warmboot(2), enableLinkLoopback(3), enableCpeLoopback(4), disableloopback(5)}read-writemandatory
ocm10gfCleiNum
OBJECT-TYPE
CLEI number of the module.
1.3.6.1.4.1.4253.1.29.2.1.20DisplayStringread-onlymandatory
ocm10gfNumPorts
OBJECT-TYPE
Total port numbers on each OCM10GF card.
1.3.6.1.4.1.4253.1.29.2.1.21INTEGERread-onlymandatory
ocm10gfFpgaRev
OBJECT-TYPE
FPGA revision for the module.
1.3.6.1.4.1.4253.1.29.2.1.22INTEGERread-onlymandatory
ocm10gfPortTable
OBJECT-TYPE
This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
1.3.6.1.4.1.4253.1.29.3not-accessiblemandatory
ocm10gfPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.29.3.1not-accessiblemandatory
ocm10gfPortLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.29.3.1.1CardLocationread-onlymandatory
ocm10gfPortShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.29.3.1.2CardShelfread-onlymandatory
ocm10gfPortSlot
OBJECT-TYPE
The slot within the shelf where the module resides.
1.3.6.1.4.1.4253.1.29.3.1.3SlotInputread-onlymandatory
ocm10gfPortIndex
OBJECT-TYPE
Port for which the below values apply.
1.3.6.1.4.1.4253.1.29.3.1.4INTEGER {link(1), cpe(2)}read-onlymandatory
ocm10gfPortMode
OBJECT-TYPE
Port mode.
1.3.6.1.4.1.4253.1.29.3.1.5INTEGER {disabled(1), enabled(2), loopback(3)}read-onlymandatory
ocm10gfPortWavelength
OBJECT-TYPE
Wavelength from port SFP.
1.3.6.1.4.1.4253.1.29.3.1.6DisplayStringread-onlymandatory
ocm10gfPortRxPower
OBJECT-TYPE
Receive power reported by port SFP.
1.3.6.1.4.1.4253.1.29.3.1.7DisplayStringread-onlymandatory
ocm10gfPortTxState
OBJECT-TYPE
State of port SFP transmitter.
1.3.6.1.4.1.4253.1.29.3.1.8INTEGER {na(0), on(1), off(2)}read-onlymandatory
ocm10gfPortTxReach
OBJECT-TYPE
Optical reach in meters reported by port SFP.
1.3.6.1.4.1.4253.1.29.3.1.9INTEGERread-onlymandatory
ocm10gfPortXfpSerialNumber
OBJECT-TYPE
Port SFP serial number.
1.3.6.1.4.1.4253.1.29.3.1.10DisplayStringread-onlymandatory
ocm10gfConnTable
OBJECT-TYPE
This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
1.3.6.1.4.1.4253.1.29.4not-accessiblemandatory
ocm10gfConnEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.29.4.1not-accessiblemandatory
ocm10gfConnCardLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.29.4.1.1CardLocationread-onlymandatory
ocm10gfConnCardShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.29.4.1.2CardShelfread-onlymandatory
ocm10gfConnCardSlot
OBJECT-TYPE
The slot within the shelf where the module resides.
1.3.6.1.4.1.4253.1.29.4.1.3SlotInputread-onlymandatory
ocm10gfConnCardPortType
OBJECT-TYPE
Port for which the below values apply.
1.3.6.1.4.1.4253.1.29.4.1.4INTEGER {linktx(1), linkrx(2), cpetx(3), cperx(4)}read-onlymandatory
ocm10gfConnCardType
OBJECT-TYPE
Module type connected to port.
1.3.6.1.4.1.4253.1.29.4.1.5CardTyperead-onlymandatory
ocm10gfConnLocation
OBJECT-TYPE
The chassis location of the card connected to this port.
1.3.6.1.4.1.4253.1.29.4.1.6CardLocationread-onlymandatory
ocm10gfConnShelf
OBJECT-TYPE
The shelf of the card connected to this port
1.3.6.1.4.1.4253.1.29.4.1.7ShelfInputread-onlymandatory
ocm10gfConnSlot
OBJECT-TYPE
The slot of the card connected to this port
1.3.6.1.4.1.4253.1.29.4.1.8SlotInputread-onlymandatory
ocm10gfConnPort
OBJECT-TYPE
Conn port for the OCM10GF's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. Entry supported by all Mux modules except MD100-40 & BD4.
1.3.6.1.4.1.4253.1.29.4.1.9INTEGERread-onlymandatory
ocm2
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.30
ocm2Number
OBJECT-TYPE
Number of rows in the ocm2 table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.30.1INTEGERread-onlymandatory
ocm2Table
OBJECT-TYPE
This table represents the information for each OCM2 card
1.3.6.1.4.1.4253.1.30.2not-accessiblemandatory
ocm2Entry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.30.2.1not-accessiblemandatory
ocm2CardLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.30.2.1.1CardLocationread-onlymandatory
ocm2CardShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.30.2.1.2CardShelfread-onlymandatory
ocm2CardSlot
OBJECT-TYPE
The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.30.2.1.3SlotInputread-writemandatory
ocm2SerialNum
OBJECT-TYPE
Module serial number.
1.3.6.1.4.1.4253.1.30.2.1.4SerialStringread-onlymandatory
ocm2ModelNum
OBJECT-TYPE
Module model number.
1.3.6.1.4.1.4253.1.30.2.1.5DisplayStringread-onlymandatory
ocm2HwName
OBJECT-TYPE
Module hardware name.
1.3.6.1.4.1.4253.1.30.2.1.6DisplayStringread-onlymandatory
ocm2HwVersionID
OBJECT-TYPE
Module hardware version.
1.3.6.1.4.1.4253.1.30.2.1.7VersionStringread-onlymandatory
ocm2MfgDate
OBJECT-TYPE
Date and Time of manufacturing of the module
1.3.6.1.4.1.4253.1.30.2.1.8DateAndTimeread-onlymandatory
ocm2FwName
OBJECT-TYPE
Module firmware name.
1.3.6.1.4.1.4253.1.30.2.1.9CardNameread-onlymandatory
ocm2FwVersionID
OBJECT-TYPE
Firmware version.
1.3.6.1.4.1.4253.1.30.2.1.10VersionStringread-onlymandatory
ocm2FwDate
OBJECT-TYPE
Firmware release date and time.
1.3.6.1.4.1.4253.1.30.2.1.11DateAndTimeread-onlymandatory
ocm2ModelType
OBJECT-TYPE
Model type of the module.
1.3.6.1.4.1.4253.1.30.2.1.12CardTyperead-onlymandatory
ocm2Name
OBJECT-TYPE
User configurable name of the module.
1.3.6.1.4.1.4253.1.30.2.1.13CardNameread-writemandatory
ocm2Link1LineRate
OBJECT-TYPE
Link 1 line rate.
1.3.6.1.4.1.4253.1.30.2.1.14INTEGER {na(0), oc3(1), oc12(2), oc48(3), gbe(4), fc(5), escon(8), fc2(10), hlf_fc(14), infiniband(15), disabled(255)}read-writemandatory
ocm2Link1AutoDisable
OBJECT-TYPE
Flag to enable/disable automatic CPE disable for Link 1.
1.3.6.1.4.1.4253.1.30.2.1.15INTEGER {na(0), enable(1), disable(2)}read-writemandatory
ocm2Link1LinkName
OBJECT-TYPE
Link 1 link name for fiber between the local and the remote card.
1.3.6.1.4.1.4253.1.30.2.1.16LinkNameread-writemandatory
ocm2Link1PathID
OBJECT-TYPE
Link 1 path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path.
1.3.6.1.4.1.4253.1.30.2.1.17PathIdNameread-writemandatory
ocm2Link2LineRate
OBJECT-TYPE
Link 2 line rate.
1.3.6.1.4.1.4253.1.30.2.1.18INTEGER {na(0), oc3(1), oc12(2), oc48(3), gbe(4), fc(5), escon(8), fc2(10), hlf_fc(14), infiniband(15), disabled(255)}read-writemandatory
ocm2Link2AutoDisable
OBJECT-TYPE
Flag to enable/disable automatic CPE disable for Link 2.
1.3.6.1.4.1.4253.1.30.2.1.19INTEGER {na(0), enable(1), disable(2)}read-writemandatory
ocm2Link2LinkName
OBJECT-TYPE
Link 2 link name for fiber between the local and the remote card.
1.3.6.1.4.1.4253.1.30.2.1.20LinkNameread-writemandatory
ocm2Link2PathID
OBJECT-TYPE
Link 2 path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path.
1.3.6.1.4.1.4253.1.30.2.1.21PathIdNameread-writemandatory
ocm2AdminState
OBJECT-TYPE
Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.
1.3.6.1.4.1.4253.1.30.2.1.22INTEGER {disable(1), enable(2), na(3)}read-writemandatory
ocm2SetState
OBJECT-TYPE
Instruct the module to do a warmboot. A get on this will always return 'other'.
1.3.6.1.4.1.4253.1.30.2.1.23INTEGER {other(1), warmboot(2), enableLink1Loopback(3), enableLink2Loopback(4), disableLink1loopback(5), disableLink2loopback(6)}read-writemandatory
ocm2CleiNum
OBJECT-TYPE
CLEI number of the module.
1.3.6.1.4.1.4253.1.30.2.1.24DisplayStringread-onlymandatory
ocm2NumPorts
OBJECT-TYPE
Total port numbers on each OCM2 card.
1.3.6.1.4.1.4253.1.30.2.1.25INTEGERread-onlymandatory
ocm2RegenMode
OBJECT-TYPE
Set or clear OCM2 regen mode.
1.3.6.1.4.1.4253.1.30.2.1.26INTEGER {enabled(1), disabled(2)}read-writemandatory
ocm2FpgaRev
OBJECT-TYPE
FPGA revision for the module.
1.3.6.1.4.1.4253.1.30.2.1.27INTEGERread-onlymandatory
ocm2PortTable
OBJECT-TYPE
This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
1.3.6.1.4.1.4253.1.30.3not-accessiblemandatory
ocm2PortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.30.3.1not-accessiblemandatory
ocm2PortLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.30.3.1.1CardLocationread-onlymandatory
ocm2PortShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.30.3.1.2CardShelfread-onlymandatory
ocm2PortSlot
OBJECT-TYPE
The slot within the shelf where the module resides.
1.3.6.1.4.1.4253.1.30.3.1.3SlotInputread-onlymandatory
ocm2PortIndex
OBJECT-TYPE
Port for which the below values apply.
1.3.6.1.4.1.4253.1.30.3.1.4INTEGER {link1(1), cpe1(2), link2(3), cpe2(4)}read-onlymandatory
ocm2PortMode
OBJECT-TYPE
Port mode.
1.3.6.1.4.1.4253.1.30.3.1.5INTEGER {na(0), disabled(1), enabled(2), loopback(3)}read-onlymandatory
ocm2PortItu
OBJECT-TYPE
Port ITU number. The ITU number is determined from the SFP wavelength.
1.3.6.1.4.1.4253.1.30.3.1.6INTEGERread-onlymandatory
ocm2PortWavelength
OBJECT-TYPE
Wavelength from port SFP.
1.3.6.1.4.1.4253.1.30.3.1.7DisplayStringread-onlymandatory
ocm2PortRxPower
OBJECT-TYPE
Receive power reported by port SFP.
1.3.6.1.4.1.4253.1.30.3.1.8DisplayStringread-onlymandatory
ocm2PortTxState
OBJECT-TYPE
State of port SFP transmitter.
1.3.6.1.4.1.4253.1.30.3.1.9INTEGER {na(0), on(1), off(2)}read-onlymandatory
ocm2PortTxReach
OBJECT-TYPE
Optical reach in meters reported by port SFP.
1.3.6.1.4.1.4253.1.30.3.1.10INTEGERread-onlymandatory
ocm2PortSfpSerialNumber
OBJECT-TYPE
Port SFP serial number.
1.3.6.1.4.1.4253.1.30.3.1.11DisplayStringread-onlymandatory
ocm2ConnTable
OBJECT-TYPE
This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
1.3.6.1.4.1.4253.1.30.4not-accessiblemandatory
ocm2ConnEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.30.4.1not-accessiblemandatory
ocm2ConnCardLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.30.4.1.1CardLocationread-onlymandatory
ocm2ConnCardShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.30.4.1.2CardShelfread-onlymandatory
ocm2ConnCardSlot
OBJECT-TYPE
The slot within the shelf where the module resides.
1.3.6.1.4.1.4253.1.30.4.1.3SlotInputread-onlymandatory
ocm2ConnCardPortType
OBJECT-TYPE
Port for which the below values apply.
1.3.6.1.4.1.4253.1.30.4.1.4INTEGER {link1tx(1), link1rx(2), link2tx(3), link2rx(4), cpe1tx(5), cpe1rx(6), cpe2tx(7), cpe2rx(8)}read-onlymandatory
ocm2ConnCardType
OBJECT-TYPE
Module type connected to port.
1.3.6.1.4.1.4253.1.30.4.1.5CardTyperead-onlymandatory
ocm2ConnLocation
OBJECT-TYPE
The chassis location of the card connected to this port.
1.3.6.1.4.1.4253.1.30.4.1.6CardLocationread-onlymandatory
ocm2ConnShelf
OBJECT-TYPE
The shelf of the card connected to this port
1.3.6.1.4.1.4253.1.30.4.1.7ShelfInputread-onlymandatory
ocm2ConnSlot
OBJECT-TYPE
The slot of the card connected to this port
1.3.6.1.4.1.4253.1.30.4.1.8SlotInputread-onlymandatory
ocm2ConnPort
OBJECT-TYPE
Conn port for the OCM2's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. Entry supported by all Mux modules except MD100-40 & BD4.
1.3.6.1.4.1.4253.1.30.4.1.9INTEGERread-onlymandatory
osc
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.31
oscNumber
OBJECT-TYPE
Number of rows in the osc table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.31.1INTEGERread-onlymandatory
oscTable
OBJECT-TYPE
This table represents the information for each OSC card
1.3.6.1.4.1.4253.1.31.2not-accessiblemandatory
oscEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.31.2.1not-accessiblemandatory
oscCardLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.31.2.1.1CardLocationread-onlymandatory
oscCardShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.31.2.1.2CardShelfread-onlymandatory
oscCardSlot
OBJECT-TYPE
The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.31.2.1.3SlotInputread-writemandatory
oscSerialNum
OBJECT-TYPE
Module serial number.
1.3.6.1.4.1.4253.1.31.2.1.4SerialStringread-onlymandatory
oscModelNum
OBJECT-TYPE
Module model number.
1.3.6.1.4.1.4253.1.31.2.1.5DisplayStringread-onlymandatory
oscHwName
OBJECT-TYPE
Module hardware name.
1.3.6.1.4.1.4253.1.31.2.1.6DisplayStringread-onlymandatory
oscHwVersionID
OBJECT-TYPE
Module hardware version.
1.3.6.1.4.1.4253.1.31.2.1.7VersionStringread-onlymandatory
oscMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the module
1.3.6.1.4.1.4253.1.31.2.1.8DateAndTimeread-onlymandatory
oscFwName
OBJECT-TYPE
Module firmware name.
1.3.6.1.4.1.4253.1.31.2.1.9CardNameread-onlymandatory
oscFwVersionID
OBJECT-TYPE
Firmware version.
1.3.6.1.4.1.4253.1.31.2.1.10VersionStringread-onlymandatory
oscFwDate
OBJECT-TYPE
Firmware release date and time.
1.3.6.1.4.1.4253.1.31.2.1.11DateAndTimeread-onlymandatory
oscAdminState
OBJECT-TYPE
Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.
1.3.6.1.4.1.4253.1.31.2.1.12INTEGER {disable(1), enable(2), na(3)}read-writemandatory
oscModelType
OBJECT-TYPE
Model type of the module.
1.3.6.1.4.1.4253.1.31.2.1.13CardTyperead-onlymandatory
oscName
OBJECT-TYPE
User configurable name of the module.
1.3.6.1.4.1.4253.1.31.2.1.14CardNameread-writemandatory
oscPathID
OBJECT-TYPE
Path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path.
1.3.6.1.4.1.4253.1.31.2.1.15PathIdNameread-writemandatory
oscSetState
OBJECT-TYPE
Instruct the module to do a warmboot. A get on this will always return 'other'.
1.3.6.1.4.1.4253.1.31.2.1.16INTEGER {other(1), warmboot(2)}read-writemandatory
oscCleiNum
OBJECT-TYPE
CLEI number of the module.
1.3.6.1.4.1.4253.1.31.2.1.17DisplayStringread-onlymandatory
oscNumPorts
OBJECT-TYPE
Total port numbers on each OSC card.
1.3.6.1.4.1.4253.1.31.2.1.18INTEGERread-onlymandatory
oscFpgaRev
OBJECT-TYPE
FPGA revision for the module.
1.3.6.1.4.1.4253.1.31.2.1.19INTEGERread-onlymandatory
oscPortTable
OBJECT-TYPE
This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
1.3.6.1.4.1.4253.1.31.3not-accessiblemandatory
oscPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.31.3.1not-accessiblemandatory
oscPortLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.31.3.1.1CardLocationread-onlymandatory
oscPortShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.31.3.1.2CardShelfread-onlymandatory
oscPortSlot
OBJECT-TYPE
The slot within the shelf where the module resides.
1.3.6.1.4.1.4253.1.31.3.1.3SlotInputread-onlymandatory
oscPortIndex
OBJECT-TYPE
Port for which the below values apply.
1.3.6.1.4.1.4253.1.31.3.1.4INTEGER {link(1)}read-onlymandatory
oscPortItu
OBJECT-TYPE
Port ITU number. The ITU number is determined from the SFP wavelength.
1.3.6.1.4.1.4253.1.31.3.1.5INTEGERread-onlymandatory
oscPortWavelength
OBJECT-TYPE
Wavelength from port SFP.
1.3.6.1.4.1.4253.1.31.3.1.6DisplayStringread-onlymandatory
oscPortRxPower
OBJECT-TYPE
Receive power reported by port SFP.
1.3.6.1.4.1.4253.1.31.3.1.7DisplayStringread-onlymandatory
oscPortTxState
OBJECT-TYPE
State of port SFP transmitter.
1.3.6.1.4.1.4253.1.31.3.1.8INTEGER {na(0), on(1), off(2)}read-onlymandatory
oscPortTxReach
OBJECT-TYPE
Optical reach in meters reported by port SFP.
1.3.6.1.4.1.4253.1.31.3.1.9INTEGERread-onlymandatory
oscPortSfpSerialNumber
OBJECT-TYPE
Port SFP serial number.
1.3.6.1.4.1.4253.1.31.3.1.10DisplayStringread-onlymandatory
ocm4g
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.32
ocm4gNumber
OBJECT-TYPE
Number of rows in the ocm4g table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.32.1INTEGERread-onlymandatory
ocm4gTable
OBJECT-TYPE
This table represents the information for each OCM4G card
1.3.6.1.4.1.4253.1.32.2not-accessiblemandatory
ocm4gEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.32.2.1not-accessiblemandatory
ocm4gCardLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.32.2.1.1INTEGER {local(1)}read-onlymandatory
ocm4gCardShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.32.2.1.2CardShelfread-onlymandatory
ocm4gCardSlot
OBJECT-TYPE
The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.32.2.1.3SlotInputread-writemandatory
ocm4gSerialNum
OBJECT-TYPE
Module serial number.
1.3.6.1.4.1.4253.1.32.2.1.4SerialStringread-onlymandatory
ocm4gModelNum
OBJECT-TYPE
Module model number.
1.3.6.1.4.1.4253.1.32.2.1.5DisplayStringread-onlymandatory
ocm4gHwName
OBJECT-TYPE
Module hardware name.
1.3.6.1.4.1.4253.1.32.2.1.6DisplayStringread-onlymandatory
ocm4gHwVersionID
OBJECT-TYPE
Module hardware version.
1.3.6.1.4.1.4253.1.32.2.1.7VersionStringread-onlymandatory
ocm4gMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the module
1.3.6.1.4.1.4253.1.32.2.1.8DateAndTimeread-onlymandatory
ocm4gFwName
OBJECT-TYPE
Module firmware name.
1.3.6.1.4.1.4253.1.32.2.1.9CardNameread-onlymandatory
ocm4gFwVersionID
OBJECT-TYPE
Firmware version.
1.3.6.1.4.1.4253.1.32.2.1.10VersionStringread-onlymandatory
ocm4gFwDate
OBJECT-TYPE
Firmware release date and time.
1.3.6.1.4.1.4253.1.32.2.1.11DateAndTimeread-onlymandatory
ocm4gModelType
OBJECT-TYPE
Model type of the module.
1.3.6.1.4.1.4253.1.32.2.1.12CardTyperead-onlymandatory
ocm4gName
OBJECT-TYPE
User configurable name of the module.
1.3.6.1.4.1.4253.1.32.2.1.13CardNameread-writemandatory
ocm4gLink1LineRate
OBJECT-TYPE
Link 1 line rate.
1.3.6.1.4.1.4253.1.32.2.1.14INTEGER {na(0), oc3(1), oc12(2), oc48(3), gbe(4), fc(5), escon(8), fc2(10), hlf_fc(14), infiniband(15), fourG(16), twoR(17), disabled(255)}read-writemandatory
ocm4gLink1AutoDisable
OBJECT-TYPE
Flag to enable/disable automatic CPE disable for Link 1.
1.3.6.1.4.1.4253.1.32.2.1.15INTEGER {na(0), enable(1), disable(2)}read-writemandatory
ocm4gLink1LinkName
OBJECT-TYPE
Link 1 link name for fiber between the local and the remote card.
1.3.6.1.4.1.4253.1.32.2.1.16LinkNameread-writemandatory
ocm4gLink1PathID
OBJECT-TYPE
Link 1 path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path.
1.3.6.1.4.1.4253.1.32.2.1.17PathIdNameread-writemandatory
ocm4gLink2LineRate
OBJECT-TYPE
Link 2 line rate.
1.3.6.1.4.1.4253.1.32.2.1.18INTEGER {na(0), oc3(1), oc12(2), oc48(3), gbe(4), fc(5), escon(8), fc2(10), hlf_fc(14), infiniband(15), fourG(16), twoR(17), disabled(255)}read-writemandatory
ocm4gLink2AutoDisable
OBJECT-TYPE
Flag to enable/disable automatic CPE disable for Link 2.
1.3.6.1.4.1.4253.1.32.2.1.19INTEGER {na(0), enable(1), disable(2)}read-writemandatory
ocm4gLink2LinkName
OBJECT-TYPE
Link 2 link name for fiber between the local and the remote card.
1.3.6.1.4.1.4253.1.32.2.1.20LinkNameread-writemandatory
ocm4gLink2PathID
OBJECT-TYPE
Link 2 path ID name associated with the module. Set input equal to NULL will remove the card off the path and also remove the path if no other modules are associated with that path.
1.3.6.1.4.1.4253.1.32.2.1.21PathIdNameread-writemandatory
ocm4gAdminState
OBJECT-TYPE
Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.
1.3.6.1.4.1.4253.1.32.2.1.22INTEGER {disable(1), enable(2), na(3)}read-writemandatory
ocm4gSetState
OBJECT-TYPE
Instruct the module to do a warmboot. A get on this will always return 'other'.
1.3.6.1.4.1.4253.1.32.2.1.23INTEGER {other(1), warmboot(2), enableLink1Loopback(3), enableLink2Loopback(4), disableLink1loopback(5), disableLink2loopback(6)}read-writemandatory
ocm4gCleiNum
OBJECT-TYPE
CLEI number of the module.
1.3.6.1.4.1.4253.1.32.2.1.24DisplayStringread-onlymandatory
ocm4gNumPorts
OBJECT-TYPE
Total port numbers on each OCM4G card.
1.3.6.1.4.1.4253.1.32.2.1.25INTEGERread-onlymandatory
ocm4gFpgaRev
OBJECT-TYPE
FPGA revision for the module.
1.3.6.1.4.1.4253.1.32.2.1.26INTEGERread-onlymandatory
ocm4gPortTable
OBJECT-TYPE
This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
1.3.6.1.4.1.4253.1.32.3not-accessiblemandatory
ocm4gPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.32.3.1not-accessiblemandatory
ocm4gPortLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.32.3.1.1INTEGER {local(1)}read-onlymandatory
ocm4gPortShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.32.3.1.2CardShelfread-onlymandatory
ocm4gPortSlot
OBJECT-TYPE
The slot within the shelf where the module resides.
1.3.6.1.4.1.4253.1.32.3.1.3SlotInputread-onlymandatory
ocm4gPortIndex
OBJECT-TYPE
Port for which the below values apply.
1.3.6.1.4.1.4253.1.32.3.1.4INTEGER {link1(1), cpe1(2), link2(3), cpe2(4)}read-onlymandatory
ocm4gPortMode
OBJECT-TYPE
Port mode.
1.3.6.1.4.1.4253.1.32.3.1.5INTEGER {na(0), disabled(1), enabled(2), loopback(3)}read-onlymandatory
ocm4gPortItu
OBJECT-TYPE
Port ITU number. The ITU number is determined from the SFP wavelength.
1.3.6.1.4.1.4253.1.32.3.1.6INTEGERread-onlymandatory
ocm4gPortWavelength
OBJECT-TYPE
Wavelength from port SFP.
1.3.6.1.4.1.4253.1.32.3.1.7DisplayStringread-onlymandatory
ocm4gPortRxPower
OBJECT-TYPE
Receive power reported by port SFP.
1.3.6.1.4.1.4253.1.32.3.1.8DisplayStringread-onlymandatory
ocm4gPortTxState
OBJECT-TYPE
State of port SFP transmitter.
1.3.6.1.4.1.4253.1.32.3.1.9INTEGER {na(0), on(1), off(2)}read-onlymandatory
ocm4gPortTxReach
OBJECT-TYPE
Optical reach in meters reported by port SFP.
1.3.6.1.4.1.4253.1.32.3.1.10INTEGERread-onlymandatory
ocm4gPortSfpSerialNumber
OBJECT-TYPE
Port SFP serial number.
1.3.6.1.4.1.4253.1.32.3.1.11DisplayStringread-onlymandatory
ocm4gConnTable
OBJECT-TYPE
This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
1.3.6.1.4.1.4253.1.32.4not-accessiblemandatory
ocm4gConnEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.32.4.1not-accessiblemandatory
ocm4gConnCardLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.32.4.1.1INTEGER {local(1)}read-onlymandatory
ocm4gConnCardShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.32.4.1.2CardShelfread-onlymandatory
ocm4gConnCardSlot
OBJECT-TYPE
The slot within the shelf where the module resides.
1.3.6.1.4.1.4253.1.32.4.1.3SlotInputread-onlymandatory
ocm4gConnCardPortType
OBJECT-TYPE
Port for which the below values apply.
1.3.6.1.4.1.4253.1.32.4.1.4INTEGER {link1tx(1), link1rx(2), link2tx(3), link2rx(4), cpe1tx(5), cpe1rx(6), cpe2tx(7), cpe2rx(8)}read-onlymandatory
ocm4gConnCardType
OBJECT-TYPE
Module type connected to port.
1.3.6.1.4.1.4253.1.32.4.1.5CardTyperead-onlymandatory
ocm4gConnLocation
OBJECT-TYPE
The chassis location of the card connected to this port.
1.3.6.1.4.1.4253.1.32.4.1.6INTEGER {local(1)}read-onlymandatory
ocm4gConnShelf
OBJECT-TYPE
The shelf of the card connected to this port
1.3.6.1.4.1.4253.1.32.4.1.7ShelfInputread-onlymandatory
ocm4gConnSlot
OBJECT-TYPE
The slot of the card connected to this port
1.3.6.1.4.1.4253.1.32.4.1.8SlotInputread-onlymandatory
ocm4gConnPort
OBJECT-TYPE
Conn port for the OCM4G's port. Possible values based on card types that can be connected to are: FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx 4=Local Rx, 5=Conn B Tx, 6=Conn B Rx OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN OSAM: 1=IN, 2=OUT W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx, 4=Link B Rx, 5=Local Tx, 6=Local Rx. Entry supported by all Mux modules except MD100-40 & BD4.
1.3.6.1.4.1.4253.1.32.4.1.9INTEGERread-onlymandatory
oet
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.33
oetNumber
OBJECT-TYPE
Number of rows in the oet table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.33.1INTEGERread-onlymandatory
oetTable
OBJECT-TYPE
This table represents the information for each OET card
1.3.6.1.4.1.4253.1.33.2not-accessiblemandatory
oetEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.33.2.1not-accessiblemandatory
oetCardLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.33.2.1.1CardLocationread-onlymandatory
oetCardShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.33.2.1.2CardShelfread-onlymandatory
oetCardSlot
OBJECT-TYPE
The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.33.2.1.3SlotInputread-writemandatory
oetSerialNum
OBJECT-TYPE
Module serial number.
1.3.6.1.4.1.4253.1.33.2.1.4SerialStringread-onlymandatory
oetModelNum
OBJECT-TYPE
Module model number.
1.3.6.1.4.1.4253.1.33.2.1.5DisplayStringread-onlymandatory
oetHwName
OBJECT-TYPE
Module hardware name.
1.3.6.1.4.1.4253.1.33.2.1.6DisplayStringread-onlymandatory
oetHwVersionID
OBJECT-TYPE
Module hardware version.
1.3.6.1.4.1.4253.1.33.2.1.7VersionStringread-onlymandatory
oetMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the module
1.3.6.1.4.1.4253.1.33.2.1.8DateAndTimeread-onlymandatory
oetFwName
OBJECT-TYPE
Module firmware name.
1.3.6.1.4.1.4253.1.33.2.1.9CardNameread-onlymandatory
oetFwVersionID
OBJECT-TYPE
Firmware version.
1.3.6.1.4.1.4253.1.33.2.1.10VersionStringread-onlymandatory
oetFwDate
OBJECT-TYPE
Firmware release date and time.
1.3.6.1.4.1.4253.1.33.2.1.11DateAndTimeread-onlymandatory
oetModelType
OBJECT-TYPE
Model type of the module.
1.3.6.1.4.1.4253.1.33.2.1.12CardTyperead-onlymandatory
oetName
OBJECT-TYPE
User configurable name of the module.
1.3.6.1.4.1.4253.1.33.2.1.13CardNameread-writemandatory
oetCleiNum
OBJECT-TYPE
CLEI number of the module.
1.3.6.1.4.1.4253.1.33.2.1.14DisplayStringread-onlymandatory
oetFpgaRevMB
OBJECT-TYPE
FPGA revision for the module's mother board.
1.3.6.1.4.1.4253.1.33.2.1.15INTEGERread-onlymandatory
oetFpgaRevDB
OBJECT-TYPE
FPGA revision for the module's daughter board.
1.3.6.1.4.1.4253.1.33.2.1.16INTEGERread-onlymandatory
oetCpldRev
OBJECT-TYPE
CPLD revision for the module.
1.3.6.1.4.1.4253.1.33.2.1.17INTEGERread-onlymandatory
oetOpMode
OBJECT-TYPE
Operating Mode (1=Mux Mode, 2=Switch Mode).
1.3.6.1.4.1.4253.1.33.2.1.18INTEGER {mux(1), switch(2)}read-writemandatory
oetProtMode
OBJECT-TYPE
Mux Protection.
1.3.6.1.4.1.4253.1.33.2.1.19INTEGER {on(1), off(2)}read-writemandatory
oetEAPSMode
OBJECT-TYPE
Ethernet Automatic Protection Switching.
1.3.6.1.4.1.4253.1.33.2.1.20INTEGER {disabled(1), linearEndpoint(2), linearNode(3), ringMaster(4), ringNode(5)}read-writemandatory
oetAdminState
OBJECT-TYPE
Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.
1.3.6.1.4.1.4253.1.33.2.1.21INTEGER {disable(1), enable(2), na(3)}read-writemandatory
oetSetState
OBJECT-TYPE
Instruct the module to do a warmboot. A get on this will always return 'other'.
1.3.6.1.4.1.4253.1.33.2.1.22INTEGER {other(1), warmboot(2)}read-writemandatory
oetConfigInProgress
OBJECT-TYPE
Configured changes are pending, Apply Changes required to finish.
1.3.6.1.4.1.4253.1.33.2.1.23INTEGER {yes(1), on(2)}read-onlymandatory
oetApplyChanges
OBJECT-TYPE
Update device with pending configuration changes. Read returns 'na'.
1.3.6.1.4.1.4253.1.33.2.1.24INTEGER {clear(1), apply(2), na(3)}read-writemandatory
oetLinkTable
OBJECT-TYPE
This table represents the information for each of the Link ports on the module.
1.3.6.1.4.1.4253.1.33.3not-accessiblemandatory
oetLinkEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.33.3.1not-accessiblemandatory
oetLinkLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.33.3.1.1CardLocationread-onlymandatory
oetLinkShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.33.3.1.2CardShelfread-onlymandatory
oetLinkSlot
OBJECT-TYPE
The slot within the shelf where the module resides.
1.3.6.1.4.1.4253.1.33.3.1.3SlotInputread-onlymandatory
oetLinkIndex
OBJECT-TYPE
Link for which the below values apply.
1.3.6.1.4.1.4253.1.33.3.1.4INTEGER {linkA(11), linkB(12)}read-onlymandatory
oetLinkEnable
OBJECT-TYPE
Enables or disables the link.
1.3.6.1.4.1.4253.1.33.3.1.5INTEGER {enable(1), disable(2)}read-writemandatory
oetLinkProtocol
OBJECT-TYPE
Protocol.
1.3.6.1.4.1.4253.1.33.3.1.6INTEGER {otu(1), lan(2)}read-writemandatory
oetLinkName
OBJECT-TYPE
Link name for fiber between the local and the remote card.
1.3.6.1.4.1.4253.1.33.3.1.7CardNameread-writemandatory
oetLinkVlanIds
OBJECT-TYPE
Comma List of VLAN Ids - single and ranges.
1.3.6.1.4.1.4253.1.33.3.1.8DisplayString (SIZE(0..80))read-writemandatory
oetLinkConfigInProgress
OBJECT-TYPE
Configured changes are pending, Apply Changes required to finish.
1.3.6.1.4.1.4253.1.33.3.1.9INTEGER {yes(1), on(2)}read-onlymandatory
oetLinkApplyChanges
OBJECT-TYPE
Update device with pending configuration changes. Read returns 'na'.
1.3.6.1.4.1.4253.1.33.3.1.10INTEGER {clear(1), apply(2), na(3)}read-writemandatory
oetLinkMode
OBJECT-TYPE
Link mode.
1.3.6.1.4.1.4253.1.33.3.1.11INTEGER {na(0), disabled(1), enabled(2), loopback(3)}read-onlymandatory
oetLinkItu
OBJECT-TYPE
Link ITU number. The ITU number is determined from the XFP wavelength.
1.3.6.1.4.1.4253.1.33.3.1.12INTEGERread-onlymandatory
oetLinkWavelength
OBJECT-TYPE
Wavelength from Link XFP.
1.3.6.1.4.1.4253.1.33.3.1.13DisplayStringread-onlymandatory
oetLinkRxPower
OBJECT-TYPE
Receive power reported by Link XFP.
1.3.6.1.4.1.4253.1.33.3.1.14DisplayStringread-onlymandatory
oetLinkTxState
OBJECT-TYPE
State of Link XFP transmitter.
1.3.6.1.4.1.4253.1.33.3.1.15INTEGER {na(0), on(1), off(2)}read-onlymandatory
oetLinkTxReach
OBJECT-TYPE
Optical reach in meters reported by Link XFP.
1.3.6.1.4.1.4253.1.33.3.1.16INTEGERread-onlymandatory
oetLinkXfpSerialNumber
OBJECT-TYPE
Link XFP serial number.
1.3.6.1.4.1.4253.1.33.3.1.17DisplayStringread-onlymandatory
oetPortTable
OBJECT-TYPE
This table represents the information for each of the CPE ports on the module.
1.3.6.1.4.1.4253.1.33.4not-accessiblemandatory
oetPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.33.4.1not-accessiblemandatory
oetPortLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.33.4.1.1CardLocationread-onlymandatory
oetPortShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.33.4.1.2CardShelfread-onlymandatory
oetPortSlot
OBJECT-TYPE
The slot within the shelf where the module resides.
1.3.6.1.4.1.4253.1.33.4.1.3SlotInputread-onlymandatory
oetPortIndex
OBJECT-TYPE
Port for which the below values apply.
1.3.6.1.4.1.4253.1.33.4.1.4INTEGER {cpe(10)}read-onlymandatory
oetPortEnable
OBJECT-TYPE
Enables or disables the port.
1.3.6.1.4.1.4253.1.33.4.1.5INTEGER {enable(1), disable(2)}read-writemandatory
oetPortALSD
OBJECT-TYPE
Auto Laser Shutoff
1.3.6.1.4.1.4253.1.33.4.1.6INTEGER {disabled(1), local(2), remote(3)}read-writemandatory
oetPortFlowControl
OBJECT-TYPE
Enable or disable the port's flow control.
1.3.6.1.4.1.4253.1.33.4.1.7INTEGER {enable(1), disable(2)}read-writemandatory
oetPortVlanId
OBJECT-TYPE
Network ID must be between 1 to 200.
1.3.6.1.4.1.4253.1.33.4.1.8INTEGER (1..200)read-writemandatory
oetPortName
OBJECT-TYPE
Port name.
1.3.6.1.4.1.4253.1.33.4.1.9CardNameread-writemandatory
oetPortConfigInProgress
OBJECT-TYPE
Configured changes are pending, Apply Changes required to finish.
1.3.6.1.4.1.4253.1.33.4.1.10INTEGER {yes(1), on(2)}read-onlymandatory
oetPortApplyChanges
OBJECT-TYPE
Update device with pending configuration changes. Read returns 'na'.
1.3.6.1.4.1.4253.1.33.4.1.11INTEGER {clear(1), apply(2), na(3)}read-writemandatory
oetPortMode
OBJECT-TYPE
Port mode.
1.3.6.1.4.1.4253.1.33.4.1.12INTEGER {na(0), disabled(1), enabled(2), loopback(3)}read-onlymandatory
oetPortItu
OBJECT-TYPE
Port ITU number. The ITU number is determined from the SFP wavelength.
1.3.6.1.4.1.4253.1.33.4.1.13INTEGERread-onlymandatory
oetPortWavelength
OBJECT-TYPE
Wavelength from Port SFP.
1.3.6.1.4.1.4253.1.33.4.1.14DisplayStringread-onlymandatory
oetPortRxPower
OBJECT-TYPE
Receive power reported by Port SFP.
1.3.6.1.4.1.4253.1.33.4.1.15DisplayStringread-onlymandatory
oetPortTxState
OBJECT-TYPE
State of Port SFP transmitter.
1.3.6.1.4.1.4253.1.33.4.1.16INTEGER {na(0), on(1), off(2)}read-onlymandatory
oetPortTxReach
OBJECT-TYPE
Optical reach in meters reported by Port SFP.
1.3.6.1.4.1.4253.1.33.4.1.17INTEGERread-onlymandatory
oetPortSfpSerialNumber
OBJECT-TYPE
Port SFP serial number.
1.3.6.1.4.1.4253.1.33.4.1.18DisplayStringread-onlymandatory
uob
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.34
uobNumber
OBJECT-TYPE
Number of rows in the uob table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.34.1INTEGERread-onlymandatory
uobTable
OBJECT-TYPE
This table represents the information for each UOB card
1.3.6.1.4.1.4253.1.34.2not-accessiblemandatory
uobEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.34.2.1not-accessiblemandatory
uobCardLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.34.2.1.1CardLocationread-onlymandatory
uobCardShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.34.2.1.2CardShelfread-onlymandatory
uobCardSlot
OBJECT-TYPE
The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.34.2.1.3SlotInputread-writemandatory
uobSerialNum
OBJECT-TYPE
Module serial number.
1.3.6.1.4.1.4253.1.34.2.1.4SerialStringread-onlymandatory
uobModelNum
OBJECT-TYPE
Module model number.
1.3.6.1.4.1.4253.1.34.2.1.5DisplayStringread-onlymandatory
uobHwName
OBJECT-TYPE
Module hardware name.
1.3.6.1.4.1.4253.1.34.2.1.6DisplayStringread-onlymandatory
uobHwVersionID
OBJECT-TYPE
Module hardware version.
1.3.6.1.4.1.4253.1.34.2.1.7VersionStringread-onlymandatory
uobMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the module
1.3.6.1.4.1.4253.1.34.2.1.8DateAndTimeread-onlymandatory
uobFwName
OBJECT-TYPE
Module firmware name.
1.3.6.1.4.1.4253.1.34.2.1.9CardNameread-onlymandatory
uobFwVersionID
OBJECT-TYPE
Firmware version.
1.3.6.1.4.1.4253.1.34.2.1.10VersionStringread-onlymandatory
uobFwDate
OBJECT-TYPE
Firmware release date and time.
1.3.6.1.4.1.4253.1.34.2.1.11DateAndTimeread-onlymandatory
uobModelType
OBJECT-TYPE
Model type of the module.
1.3.6.1.4.1.4253.1.34.2.1.12CardTyperead-onlymandatory
uobCfgName
OBJECT-TYPE
User configurable name of the module.
1.3.6.1.4.1.4253.1.34.2.1.13CardNameread-writemandatory
uobModuleName
OBJECT-TYPE
name of the module.
1.3.6.1.4.1.4253.1.34.2.1.14DisplayStringread-onlymandatory
uobAdminState
OBJECT-TYPE
Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.
1.3.6.1.4.1.4253.1.34.2.1.15INTEGER {disable(1), enable(2), na(3)}read-writemandatory
uobSetState
OBJECT-TYPE
Instruct the module to do a warmboot. A get on this will always return 'other'.
1.3.6.1.4.1.4253.1.34.2.1.16INTEGER {other(1), warmboot(2)}read-writemandatory
uobCleiNum
OBJECT-TYPE
CLEI number of the module.
1.3.6.1.4.1.4253.1.34.2.1.17DisplayStringread-onlymandatory
uobFpgaRev
OBJECT-TYPE
FPGA revision for the module.
1.3.6.1.4.1.4253.1.34.2.1.18INTEGERread-onlymandatory
uobOperationMode
OBJECT-TYPE
Invalid, Constain Power, Constant Gain, Disabled. Constain Power(1) is not valid on Fixed modules.
1.3.6.1.4.1.4253.1.34.2.1.19INTEGER {invalid(0), constainPower(1), constantGain(2), disabled(3)}read-writemandatory
uobOutPower
OBJECT-TYPE
uobModuleName - Configured Power in dBm T17VO - range: -13.0 to 17.5 T17VR - range: -13.0 to 17.5 T20FR - range: -7.0 to 20.10 T15FR - range: -7.0 to 15.10
1.3.6.1.4.1.4253.1.34.2.1.20DisplayStringread-writemandatory
uobGain
OBJECT-TYPE
uobModuleName - Configured Gain in dB T17VO - range: 10.0 to 20.0 T17VR - range: 10.0 to 20.0 T20FR - range: 16.0 to 28.0 default:22 T15FR - range: 16.0 to 28.0 default:22
1.3.6.1.4.1.4253.1.34.2.1.21DisplayStringread-writemandatory
uobGainTilt
OBJECT-TYPE
uobModuleName - Configured Gain Tilt in dB T17VO - range: -2.0 to 2.0 T17VR - range: -2.0 to 2.0
1.3.6.1.4.1.4253.1.34.2.1.22DisplayStringread-writemandatory
uobLosMode
OBJECT-TYPE
No effect, Disabled in all modes, Disabled in Power Mode only
1.3.6.1.4.1.4253.1.34.2.1.23INTEGER {noEffect(1), disabledInAll(2), disabledInPower(3)}read-writemandatory
uobLosThreshold
OBJECT-TYPE
uobModuleName - Configured Los Threshold in dBm T17VO - range: -100.0 to 45.0 default: -31 T17VR - range: -100.0 to 45.0 default: -31 T20FR - range: -40.0 to -5.0 default: -35 T15FR - range: -40.0 to -5.0 default: -35
1.3.6.1.4.1.4253.1.34.2.1.24DisplayStringread-writemandatory
uobRflThreshold
OBJECT-TYPE
uobModuleName - Configured Rfl Threshold in dB T17VO - range: 0.0 to 50.0 T17VR - range: -23.0 to -14.0 T20FR - range: -23.0 to -14.0 T15FR - range: -23.0 to -14.0
1.3.6.1.4.1.4253.1.34.2.1.25DisplayStringread-writemandatory
fc8g
OBJECT-IDENTITY
1.3.6.1.4.1.4253.1.35
fc8gNumber
OBJECT-TYPE
Number of rows in the fc8g table. This number is automatically updated whenever a new row is added to the table below.
1.3.6.1.4.1.4253.1.35.1INTEGERread-onlymandatory
fc8gTable
OBJECT-TYPE
This table represents the information for each FC8G card
1.3.6.1.4.1.4253.1.35.2not-accessiblemandatory
fc8gEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.35.2.1not-accessiblemandatory
fc8gCardLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.35.2.1.1INTEGER {local(1)}read-onlymandatory
fc8gCardShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.35.2.1.2CardShelfread-onlymandatory
fc8gCardSlot
OBJECT-TYPE
The slot within the shelf where the module resides. The range of valid values range from 1 through 17 depending on the chassis type and the shelf where the module is in. To delete this card, set this variable to 0.
1.3.6.1.4.1.4253.1.35.2.1.3SlotInputread-writemandatory
fc8gSerialNum
OBJECT-TYPE
Module serial number.
1.3.6.1.4.1.4253.1.35.2.1.4SerialStringread-onlymandatory
fc8gModelNum
OBJECT-TYPE
Module model number.
1.3.6.1.4.1.4253.1.35.2.1.5DisplayStringread-onlymandatory
fc8gHwName
OBJECT-TYPE
Module hardware name.
1.3.6.1.4.1.4253.1.35.2.1.6DisplayStringread-onlymandatory
fc8gHwVersionID
OBJECT-TYPE
Module hardware version.
1.3.6.1.4.1.4253.1.35.2.1.7VersionStringread-onlymandatory
fc8gMfgDate
OBJECT-TYPE
Date and Time of manufacturing of the module
1.3.6.1.4.1.4253.1.35.2.1.8DateAndTimeread-onlymandatory
fc8gFwName
OBJECT-TYPE
Module firmware name.
1.3.6.1.4.1.4253.1.35.2.1.9CardNameread-onlymandatory
fc8gFwVersionID
OBJECT-TYPE
Firmware version.
1.3.6.1.4.1.4253.1.35.2.1.10VersionStringread-onlymandatory
fc8gFwDate
OBJECT-TYPE
Firmware release date and time.
1.3.6.1.4.1.4253.1.35.2.1.11DateAndTimeread-onlymandatory
fc8gModelType
OBJECT-TYPE
Model type of the module.
1.3.6.1.4.1.4253.1.35.2.1.12CardTyperead-onlymandatory
fc8gName
OBJECT-TYPE
User configurable name of the module.
1.3.6.1.4.1.4253.1.35.2.1.13CardNameread-writemandatory
fc8gLink1DataRate
OBJECT-TYPE
Link 1 Data rate.
1.3.6.1.4.1.4253.1.35.2.1.14INTEGER {dr8G(1), dr4G(2), dr2G(3), dr1G(4)}read-writemandatory
fc8gCpe1AutoDisable
OBJECT-TYPE
Flag to enable/disable automatic CPE disable for Link 1.
1.3.6.1.4.1.4253.1.35.2.1.15INTEGER {enable(1), disable(2)}read-writemandatory
fc8gCpe1LaserEnabled
OBJECT-TYPE
Flag to enable/disable the CPE laser for Link 1.
1.3.6.1.4.1.4253.1.35.2.1.16INTEGER {enable(1), disable(2)}read-writemandatory
fc8gLink1LaserEnabled
OBJECT-TYPE
Flag to enable/disable the LINK laser for Link 1.
1.3.6.1.4.1.4253.1.35.2.1.17INTEGER {enable(1), disable(2)}read-writemandatory
fc8gLink2DataRate
OBJECT-TYPE
Link 2 Data rate.
1.3.6.1.4.1.4253.1.35.2.1.18INTEGER {dr8G(1), dr4G(2), dr2G(3), dr1G(4)}read-writemandatory
fc8gCpe2AutoDisable
OBJECT-TYPE
Flag to enable/disable automatic CPE disable for Link 2.
1.3.6.1.4.1.4253.1.35.2.1.19INTEGER {enable(1), disable(2)}read-writemandatory
fc8gCpe2LaserEnabled
OBJECT-TYPE
Flag to enable/disable the CPE laser for Link 2.
1.3.6.1.4.1.4253.1.35.2.1.20INTEGER {enable(1), disable(2)}read-writemandatory
fc8gLink2LaserEnabled
OBJECT-TYPE
Flag to enable/disable the LINK laser for Link 2.
1.3.6.1.4.1.4253.1.35.2.1.21INTEGER {enable(1), disable(2)}read-writemandatory
fc8gAdminState
OBJECT-TYPE
Administrative control for the module. Default value is enable. When disabled, no alarms/events are generated for the module.
1.3.6.1.4.1.4253.1.35.2.1.22INTEGER {disable(1), enable(2)}read-writemandatory
fc8gSetState
OBJECT-TYPE
Instruct the module to do a warmboot or loopback. Successive loopbacks can be issued. A get on this will always return 'other'.
1.3.6.1.4.1.4253.1.35.2.1.23INTEGER {other(1), warmboot(2), enableChannel1LinkLoopback(3), enableChannel1CpeLoopback(4), enableChannel2LinkLoopback(5), enableChannel2CpeLoopback(6), disableChannel1loopback(7), disableChannel2loopback(8)}read-writemandatory
fc8gPortTable
OBJECT-TYPE
This table represents the information for each set of ports on the module. Ports are divided into two sets: mux ports and demux ports.
1.3.6.1.4.1.4253.1.35.3not-accessiblemandatory
fc8gPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.1.35.3.1not-accessiblemandatory
fc8gPortLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.1.35.3.1.1CardLocationread-onlymandatory
fc8gPortShelf
OBJECT-TYPE
The shelf where the module resides.
1.3.6.1.4.1.4253.1.35.3.1.2CardShelfread-onlymandatory
fc8gPortSlot
OBJECT-TYPE
The slot within the shelf where the module resides.
1.3.6.1.4.1.4253.1.35.3.1.3SlotInputread-onlymandatory
fc8gPortIndex
OBJECT-TYPE
Port for which the below values apply.
1.3.6.1.4.1.4253.1.35.3.1.4INTEGER {link1(1), cpe1(2), link2(3), cpe2(4)}read-onlymandatory
fc8gPortName
OBJECT-TYPE
Port name.
1.3.6.1.4.1.4253.1.35.3.1.5CardNameread-onlymandatory
fc8gPortMode
OBJECT-TYPE
Port mode.
1.3.6.1.4.1.4253.1.35.3.1.6INTEGER {enabled(1), loopback(2)}read-onlymandatory
fc8gPortWavelength
OBJECT-TYPE
Port wavelength.
1.3.6.1.4.1.4253.1.35.3.1.7DisplayStringread-onlymandatory
fc8gPortRxPower
OBJECT-TYPE
Reported port receive power.
1.3.6.1.4.1.4253.1.35.3.1.8DisplayStringread-onlymandatory
fc8gPortTxState
OBJECT-TYPE
State of port transmitter.
1.3.6.1.4.1.4253.1.35.3.1.9INTEGER {na(0), on(1), off(2)}read-onlymandatory
fc8gPortTxReach
OBJECT-TYPE
Port optical reach in meters.
1.3.6.1.4.1.4253.1.35.3.1.10INTEGERread-onlymandatory
fc8gPortSfpXfpSerialNumber
OBJECT-TYPE
Port SFP/XFP serial number.
1.3.6.1.4.1.4253.1.35.3.1.11DisplayStringread-onlymandatory
performance
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2
current1
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1
systemPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.1
sysStatus
OBJECT-TYPE
The global status of the system as computed based on the traps (events) that are generated. Choices are: Critical, Major, Minor or Normal.
1.3.6.1.4.1.4253.2.1.1.1CardStatusread-onlymandatory
sysClearStatus
OBJECT-TYPE
Reset the system state to Normal. The value of reset means set the state to Normal. A get on this will always return other. Note: This element is now made not-accessible as sysStatus is now a read-only element
1.3.6.1.4.1.4253.2.1.1.2ResetTypenot-accessiblemandatory
sysClearCounters
OBJECT-TYPE
Reset all performance counters in this 15 minutes time interval to zero. The value of reset means to reset the counters to zero. A get on this will always return other.
1.3.6.1.4.1.4253.2.1.1.3ResetTyperead-writemandatory
sysLastBootTime
OBJECT-TYPE
The date and time of the last system boot. This time represents the boot time of a CP card. It is also anonymous with the power-up cycle of the chassis.
1.3.6.1.4.1.4253.2.1.1.4DateAndTimeread-onlymandatory
sysAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that the system has been up and running. This will generally be the same as 15 minutes in seconds (900), but, if the system has been reboot in the last 15 minutes interval, then it represents the number of seconds the system has been up. The criteria for the system available time is having at least one CP running with atmost non-service affecting minor alarm system status
1.3.6.1.4.1.4253.2.1.1.5Counterread-onlymandatory
sysErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that the device has not experienced any alarms. This counter is across all cards in the chassis. The system must be in Normal status for this counter to be incremented.
1.3.6.1.4.1.4253.2.1.1.6Counterread-onlymandatory
sysExhaustTemperature
OBJECT-TYPE
Temperature of the Chassis. Units of dgree centigrade.
1.3.6.1.4.1.4253.2.1.1.7INTEGERread-onlymandatory
downloadPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.2
dlStatus
OBJECT-TYPE
The global status of the download task. The download task (download to the device) is either ftp_inprogress, module update inprogrss or currently idle. Since only one download at the time is handled by the system, this flag is set to inprogress as soon as any download starts. It is reset back to idle when the download is completed. This flag is set to idle on system startup. This flag can be remotely set to idle if a previous FTP download was interrupted.
1.3.6.1.4.1.4253.2.1.2.1DownloadStatusread-writemandatory
dlOkDownloads
OBJECT-TYPE
The number of successful downloads in this time interval (15 minutes).
1.3.6.1.4.1.4253.2.1.2.2Counterread-onlymandatory
dlBadDownloads
OBJECT-TYPE
The number of failed downloads in this time interval (15 minutes).
1.3.6.1.4.1.4253.2.1.2.3Counterread-onlymandatory
dlLongestTime
OBJECT-TYPE
Longest time for any download, in seconds, in this time interval (15 minutes).
1.3.6.1.4.1.4253.2.1.2.4Gaugeread-onlymandatory
dlLongestSize
OBJECT-TYPE
Longest download size for any download, in bytes, in this time interval (15 minutes).
1.3.6.1.4.1.4253.2.1.2.5Gaugeread-onlymandatory
cpPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.3
cpNumEvents
OBJECT-TYPE
Total number of events received by the active CP in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.3.1Counterread-onlymandatory
cpTrapsSent
OBJECT-TYPE
Total number of traps sent by the active CP in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.3.2Counterread-onlymandatory
cpSNMPCmdsRcvd
OBJECT-TYPE
Total number of SNMP commands received by the active CP in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.3.3Counterread-onlymandatory
cpCounterFlag
OBJECT-TYPE
Turns software counters On or Off.
1.3.6.1.4.1.4253.2.1.3.4FlagTyperead-writemandatory
cpCntrTable
OBJECT-TYPE
This table represents the information for each entry of the software counters. It is only applicable to the active MPM card.
1.3.6.1.4.1.4253.2.1.3.5not-accessiblemandatory
cpCntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.3.5.1not-accessiblemandatory
cpCntrShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the value of the current active CP card.
1.3.6.1.4.1.4253.2.1.3.5.1.1CardShelfread-onlymandatory
cpCntrSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the value of the current active CP card.
1.3.6.1.4.1.4253.2.1.3.5.1.2CardSlotread-onlymandatory
cpCntrType
OBJECT-TYPE
The type of the software counter data in this row. The data is collected for the SPI data channels.
1.3.6.1.4.1.4253.2.1.3.5.1.3INTEGER {spi(1)}read-onlymandatory
cpTotPktSent
OBJECT-TYPE
The number of data packets sent over the given data channel.
1.3.6.1.4.1.4253.2.1.3.5.1.4Counterread-onlymandatory
cpTotPktRcvd
OBJECT-TYPE
The number of data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.3.5.1.5Counterread-onlymandatory
cpBadPktRcvd
OBJECT-TYPE
The number of bad data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.3.5.1.6Counterread-onlymandatory
cpTotBadTrans
OBJECT-TYPE
The number of bad data transmissions over the given data channel.
1.3.6.1.4.1.4253.2.1.3.5.1.7Counterread-onlymandatory
cpBytesSent
OBJECT-TYPE
Total number of bytes sent over the given data channel.
1.3.6.1.4.1.4253.2.1.3.5.1.8Counterread-onlymandatory
cpBytesRcvd
OBJECT-TYPE
Total number of data bytes received over the given data channel.
1.3.6.1.4.1.4253.2.1.3.5.1.9Counterread-onlymandatory
cpMsgsDlvrd
OBJECT-TYPE
The number of complete messages delivered over the given data channel.
1.3.6.1.4.1.4253.2.1.3.5.1.10Counterread-onlymandatory
cpBufAllocFail
OBJECT-TYPE
Number of buffer allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.1.3.5.1.11Counterread-onlymandatory
cpEcbAllocFail
OBJECT-TYPE
Number of Event Control Block allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.1.3.5.1.12Counterread-onlymandatory
cpClearCntrs
OBJECT-TYPE
If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other
1.3.6.1.4.1.4253.2.1.3.5.1.13ResetTyperead-writemandatory
cpPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each communication processor
1.3.6.1.4.1.4253.2.1.3.6not-accessiblemandatory
cpPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.3.6.1not-accessiblemandatory
cpPerfShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2
1.3.6.1.4.1.4253.2.1.3.6.1.1CardShelfread-onlymandatory
cpPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 3
1.3.6.1.4.1.4253.2.1.3.6.1.2CardSlotread-onlymandatory
cpPerfMode
OBJECT-TYPE
The valid types are: active CP or standby CP
1.3.6.1.4.1.4253.2.1.3.6.1.3RedundancyModeread-onlymandatory
cpPerfState
OBJECT-TYPE
The status of the communication card. The status' are: online, offline, empty, loopback or diagnostics.
1.3.6.1.4.1.4253.2.1.3.6.1.4CardStateread-onlymandatory
cpPerfStatus
OBJECT-TYPE
The status of the communication processor. This status represents the state of the communication processor and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.3.6.1.5CardStatusread-onlymandatory
cpLastBootTime
OBJECT-TYPE
The date and time of the last boot for this CP.
1.3.6.1.4.1.4253.2.1.3.6.1.6DateAndTimeread-onlymandatory
cpAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this CP has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.3.6.1.7Counterread-onlymandatory
cpErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this CP has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.3.6.1.8Counterread-onlymandatory
ccPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.4
ccNumEvents
OBJECT-TYPE
Total number of events received for all CC's in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.4.1Counterread-onlymandatory
ccCntrTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.1.4.2not-accessiblemandatory
ccCntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.4.2.1not-accessiblemandatory
ccCntrLocation
OBJECT-TYPE
The location of the CC card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known CC cards.
1.3.6.1.4.1.4253.2.1.4.2.1.1CardLocationread-onlymandatory
ccCntrShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) CC cards.
1.3.6.1.4.1.4253.2.1.4.2.1.2CardShelfread-onlymandatory
ccCntrSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) CC cards.
1.3.6.1.4.1.4253.2.1.4.2.1.3CardSlotread-onlymandatory
ccCntrType
OBJECT-TYPE
The type of the software counter data in this row. The data is collected for the SPI data channels.
1.3.6.1.4.1.4253.2.1.4.2.1.4INTEGER {spi(1), iwm(2)}read-onlymandatory
ccCounterFlag
OBJECT-TYPE
Turns software counters, both On or both Off for this CC. When set to Off, both counters statistic information will be cleared.
1.3.6.1.4.1.4253.2.1.4.2.1.5FlagTyperead-writemandatory
ccTotPktSent
OBJECT-TYPE
The number of data packets sent over the given data channel.
1.3.6.1.4.1.4253.2.1.4.2.1.6Counterread-onlymandatory
ccTotPktRcvd
OBJECT-TYPE
The number of data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.4.2.1.7Counterread-onlymandatory
ccBadPktRcvd
OBJECT-TYPE
The number of bad data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.4.2.1.8Counterread-onlymandatory
ccTotBadTrans
OBJECT-TYPE
The number of bad data transmissions over the given data channel.
1.3.6.1.4.1.4253.2.1.4.2.1.9Counterread-onlymandatory
ccBytesSent
OBJECT-TYPE
Total number of bytes sent over the given data channel.
1.3.6.1.4.1.4253.2.1.4.2.1.10Counterread-onlymandatory
ccBytesRcvd
OBJECT-TYPE
Total number of data bytes received over the given data channel.
1.3.6.1.4.1.4253.2.1.4.2.1.11Counterread-onlymandatory
ccMsgsDlvrd
OBJECT-TYPE
The number of complete messages delivered over the given data channel.
1.3.6.1.4.1.4253.2.1.4.2.1.12Counterread-onlymandatory
ccBufAllocFail
OBJECT-TYPE
Number of buffer allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.1.4.2.1.13Counterread-onlymandatory
ccEcbAllocFail
OBJECT-TYPE
Number of Event Control Block allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.1.4.2.1.14Counterread-onlymandatory
ccClearCntrs
OBJECT-TYPE
If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other
1.3.6.1.4.1.4253.2.1.4.2.1.15ResetTyperead-writemandatory
ccPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each channel card
1.3.6.1.4.1.4253.2.1.4.3not-accessiblemandatory
ccPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.4.3.1not-accessiblemandatory
ccPerfLocation
OBJECT-TYPE
The location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) CC cards.
1.3.6.1.4.1.4253.2.1.4.3.1.1CardLocationread-onlymandatory
ccPerfShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.1.4.3.1.2CardShelfread-onlymandatory
ccPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 4 to 42
1.3.6.1.4.1.4253.2.1.4.3.1.3CardSlotread-onlymandatory
ccPerfState
OBJECT-TYPE
The state of the channel card. The states' are: online, offline, empty, loopback or diagnostics.
1.3.6.1.4.1.4253.2.1.4.3.1.4CardStateread-onlymandatory
ccPerfStatus
OBJECT-TYPE
The status of the channel card. This status represents the status of the communication processor and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.4.3.1.5CardStatusread-onlymandatory
ccLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.1.4.3.1.6DateAndTimeread-onlymandatory
ccAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this CC has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.4.3.1.7Counterread-onlymandatory
ccErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this CC has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.4.3.1.8Counterread-onlymandatory
ccBiasCurrent
OBJECT-TYPE
Bias current for the optical laser.
1.3.6.1.4.1.4253.2.1.4.3.1.9INTEGERread-onlymandatory
ccModulation
OBJECT-TYPE
The frequency modulation for the optical laser.
1.3.6.1.4.1.4253.2.1.4.3.1.10INTEGERread-onlymandatory
ccApc
OBJECT-TYPE
The APC value.
1.3.6.1.4.1.4253.2.1.4.3.1.11INTEGERread-onlymandatory
ccIwmModulation
OBJECT-TYPE
The frequency modulation for the IWM channel.
1.3.6.1.4.1.4253.2.1.4.3.1.12INTEGERread-onlymandatory
ccLaserOnOff
OBJECT-TYPE
The laser On/Off flag.
1.3.6.1.4.1.4253.2.1.4.3.1.13FlagTyperead-onlymandatory
ccTemperature
OBJECT-TYPE
The current temperature, or the operating temperature of the optical device.
1.3.6.1.4.1.4253.2.1.4.3.1.14Gaugeread-onlymandatory
ccIntensity
OBJECT-TYPE
The intensity of the optical light.
1.3.6.1.4.1.4253.2.1.4.3.1.15Gaugeread-onlymandatory
ccSignalStrength
OBJECT-TYPE
The current signal strength for the optical path.
1.3.6.1.4.1.4253.2.1.4.3.1.16Gaugeread-onlymandatory
ccLossOfLight
OBJECT-TYPE
If set to true, no laser light is present. If set to false, no loss of light has occurred.
1.3.6.1.4.1.4253.2.1.4.3.1.17Booleanread-onlymandatory
ccSignalDetect
OBJECT-TYPE
If set to true, signal is detected. If set to false, no signal is present. Replaced with ccCpeRxSigDetect
1.3.6.1.4.1.4253.2.1.4.3.1.18Booleannot-accessiblemandatory
ccRefClock
OBJECT-TYPE
The value of the reference clock in decimal notation. For a given value, like 1660, the actual value is 16.60-EN. In otherwords, assume a two digit decimal point, plus any appropriate scaling factor.
1.3.6.1.4.1.4253.2.1.4.3.1.19INTEGER {en1660(1), en1944(2), en1953(3)}not-accessiblemandatory
ccClockDiv
OBJECT-TYPE
The clock divisor. Values are 1250, 622 or 155 in the appropriate clock frequency scale.
1.3.6.1.4.1.4253.2.1.4.3.1.20INTEGER {dout-1250(1), dout-622(2), dout-155(3)}not-accessiblemandatory
ccLinkTxPwrStatus
OBJECT-TYPE
This indicates whether the link transmit power is within the normal range of operation.
1.3.6.1.4.1.4253.2.1.4.3.1.21INTEGER {ok(1), fault(2)}read-onlymandatory
ccLinkRxSigStrStatus
OBJECT-TYPE
This indicates whether the link's receive signal is within the normal range of operation.
1.3.6.1.4.1.4253.2.1.4.3.1.22INTEGER {ok(1), fault(2)}read-onlymandatory
ccCpeRxSigDetect
OBJECT-TYPE
This indicates whether there is presence of CPE receive signal
1.3.6.1.4.1.4253.2.1.4.3.1.23INTEGER {yes(1), no(2)}read-onlymandatory
ccLinkIWMStatus
OBJECT-TYPE
This indicates the current status of IWM. This value is only applicable to remote OCMs
1.3.6.1.4.1.4253.2.1.4.3.1.24INTEGER {ok(1), error(2), notApplicable(3)}read-onlymandatory
ccLinkSummaryStatus
OBJECT-TYPE
This is the result of a logical and operation of all the individual link status. If any of the attributes is N/A, except for the local local IWM status, this value is N/A
1.3.6.1.4.1.4253.2.1.4.3.1.25INTEGER {ok(1), fault(2), notApplicable(3)}read-onlymandatory
ccProtectionMode
OBJECT-TYPE
UPSR Protection Mode: active, standby and n/a.
1.3.6.1.4.1.4253.2.1.4.3.1.26INTEGER {working(1), protection(2), na(3)}read-onlymandatory
ccLinkRxSigStr
OBJECT-TYPE
Link's received signal strength in dBm.
1.3.6.1.4.1.4253.2.1.4.3.1.27DisplayStringread-onlymandatory
muxPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.5
muxNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all MUX's in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.5.1Counterread-onlymandatory
muxPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each mux/demux card
1.3.6.1.4.1.4253.2.1.5.2not-accessiblemandatory
muxPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.5.2.1not-accessiblemandatory
muxPerfLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.1.5.2.1.1CardLocationread-onlymandatory
muxPerfShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.1.5.2.1.2CardShelfread-onlymandatory
muxPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 42
1.3.6.1.4.1.4253.2.1.5.2.1.3CardSlotread-onlymandatory
muxType
OBJECT-TYPE
The type of the mux. The choices are: mux or demux.
1.3.6.1.4.1.4253.2.1.5.2.1.4CardTyperead-onlymandatory
muxPerfState
OBJECT-TYPE
The state of the mux card. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.1.5.2.1.5CardStateread-onlymandatory
muxPerfStatus
OBJECT-TYPE
The status of the mux card. This status represents the status of the mux card and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.5.2.1.6CardStatusread-onlymandatory
muxLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.1.5.2.1.7DateAndTimeread-onlymandatory
muxAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this Mux has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.5.2.1.8Counterread-onlymandatory
muxErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this mux has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.5.2.1.9Counterread-onlymandatory
psPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.6
psNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all Power Supplies in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.6.1Counterread-onlymandatory
psVoltageLevel3pt4Volt
OBJECT-TYPE
Voltage Level of the 3.4 V power supply.
1.3.6.1.4.1.4253.2.1.6.2DisplayString (SIZE(0..10))read-onlymandatory
psVoltageLevel5pt1Volt
OBJECT-TYPE
Voltage Level of the 5.1 V power supply.
1.3.6.1.4.1.4253.2.1.6.3DisplayString (SIZE(0..10))read-onlymandatory
psVoltageLevel12Volt
OBJECT-TYPE
Voltage Level of the 12 V power supply.
1.3.6.1.4.1.4253.2.1.6.4DisplayString (SIZE(0..10))read-onlymandatory
psPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each power supply card
1.3.6.1.4.1.4253.2.1.6.5not-accessiblemandatory
psPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.6.5.1not-accessiblemandatory
psPerfID
OBJECT-TYPE
The module ID where the PS is plugged in.
1.3.6.1.4.1.4253.2.1.6.5.1.1INTEGERread-onlymandatory
psPerfType
OBJECT-TYPE
The type of the power supply.
1.3.6.1.4.1.4253.2.1.6.5.1.2INTEGER {psDC(1), psAC(2), unknown(3)}read-onlymandatory
psPerfState
OBJECT-TYPE
The state of the power supply module.
1.3.6.1.4.1.4253.2.1.6.5.1.3INTEGER {psEmpty(1), psOK(2), psFailed(3), psDegrade(4)}read-onlymandatory
psPerfStatus
OBJECT-TYPE
The status of the power supply module. This status represents the status of the ps module and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.6.5.1.4CardStatusread-onlymandatory
psVoltageLevelFeedA
OBJECT-TYPE
Voltage Level of the -48 VDC input from Feed A.
1.3.6.1.4.1.4253.2.1.6.6DisplayString (SIZE(0..10))read-onlymandatory
psVoltageLevelFeedB
OBJECT-TYPE
Voltage Level of the -48 VDC input from Feed B.
1.3.6.1.4.1.4253.2.1.6.7DisplayString (SIZE(0..10))read-onlymandatory
psBreakerConditionFeedA
OBJECT-TYPE
State of Feed A breaker.
1.3.6.1.4.1.4253.2.1.6.8INTEGER {open(1), closed(2), na(3)}read-onlymandatory
psPerfStatusFeedA
OBJECT-TYPE
State of Feed A breaker. Failed if it goes into shutdown condition Unknown if the corresponding breaker is open
1.3.6.1.4.1.4253.2.1.6.9INTEGER {feedOK(1), feedFAILED(2), feedUNKNOWN(3), na(4)}read-onlymandatory
psBreakerConditionFeedB
OBJECT-TYPE
State of Feed B breaker.
1.3.6.1.4.1.4253.2.1.6.10INTEGER {open(1), closed(2), na(3)}read-onlymandatory
psPerfStatusFeedB
OBJECT-TYPE
State of Feed B. Failed if it goes into shutdown condition Unknown if the corresponding breaker is open
1.3.6.1.4.1.4253.2.1.6.11INTEGER {feedOK(1), feedFAILED(2), feedUNKNOWN(3), na(4)}read-onlymandatory
fadmPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.7
fadmNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all MUX's in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.7.1Counterread-onlymandatory
fadmPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each fadm card
1.3.6.1.4.1.4253.2.1.7.2not-accessiblemandatory
fadmPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.7.2.1not-accessiblemandatory
fadmPerfLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.1.7.2.1.1CardLocationread-onlymandatory
fadmPerfShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.1.7.2.1.2CardShelfread-onlymandatory
fadmPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 42
1.3.6.1.4.1.4253.2.1.7.2.1.3CardSlotread-onlymandatory
fadmPerfState
OBJECT-TYPE
The status of the fadm card. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.1.7.2.1.4CardStateread-onlymandatory
fadmPerfStatus
OBJECT-TYPE
The status of the fadm card. This status represents the status of the fadm card and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.7.2.1.5CardStatusread-onlymandatory
fadmLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.1.7.2.1.6DateAndTimeread-onlymandatory
fadmAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this fadm card has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.7.2.1.7Counterread-onlymandatory
fadmErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this fadm card has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.7.2.1.8Counterread-onlymandatory
oppmPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.8
oppmNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all OPPM's in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.8.1Counternot-accessiblemandatory
oppmPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each oppm card
1.3.6.1.4.1.4253.2.1.8.2not-accessiblemandatory
oppmPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.8.2.1not-accessiblemandatory
oppmPerfLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.1.8.2.1.1CardLocationnot-accessiblemandatory
oppmPerfShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.1.8.2.1.2CardShelfnot-accessiblemandatory
oppmPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 4 to 42
1.3.6.1.4.1.4253.2.1.8.2.1.3CardSlotnot-accessiblemandatory
oppmPerfState
OBJECT-TYPE
The state of the oppm card. The states are: online, offline.
1.3.6.1.4.1.4253.2.1.8.2.1.4CardStatenot-accessiblemandatory
oppmPerfStatus
OBJECT-TYPE
The status of the oppm card. This status represents the status of the oppm card and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.8.2.1.5CardStatusnot-accessiblemandatory
oppmLinkAState
OBJECT-TYPE
The state of the oppm card. The states are: linked, notLinked.
1.3.6.1.4.1.4253.2.1.8.2.1.6INTEGER {linked(1), notLinked(2), unknown(3)}not-accessiblemandatory
oppmLinkAStatus
OBJECT-TYPE
The status of the card channel. This status represents the status of the link A of the card and in general is different from the status of the card.
1.3.6.1.4.1.4253.2.1.8.2.1.7INTEGER {active(1), standby(2), hibernation(3)}not-accessiblemandatory
oppmLinkBState
OBJECT-TYPE
The state of the oppm card link B. The states are: linked, notLinked.
1.3.6.1.4.1.4253.2.1.8.2.1.8INTEGER {linked(1), notLinked(2), unknown(3)}not-accessiblemandatory
oppmLinkBStatus
OBJECT-TYPE
The status of the card channel. This status represents the status of the link B of the card and in general is different from the status of the card.
1.3.6.1.4.1.4253.2.1.8.2.1.9INTEGER {active(1), standby(2), hibernation(3)}not-accessiblemandatory
oppmLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.1.8.2.1.10DateAndTimenot-accessiblemandatory
oppmAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this oppm card has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.8.2.1.11Counternot-accessiblemandatory
oppmErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this oppm card has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.8.2.1.12Counternot-accessiblemandatory
oppmWorkingPower
OBJECT-TYPE
working power displayed in dBm unit
1.3.6.1.4.1.4253.2.1.8.2.1.13INTEGERnot-accessiblemandatory
oppmProtectPower
OBJECT-TYPE
protect power displayed in dBm unit
1.3.6.1.4.1.4253.2.1.8.2.1.14INTEGERnot-accessiblemandatory
mcmPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.9
mcmNumEvents
OBJECT-TYPE
Total number of events received for all mcmt1's/mcme1's in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.9.1Counterread-onlymandatory
mcmCntrTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.1.9.2not-accessiblemandatory
mcmCntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.9.2.1not-accessiblemandatory
mcmCntrLocation
OBJECT-TYPE
The location of the mcmt1/mcme1 card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmt1/mcme1 cards.
1.3.6.1.4.1.4253.2.1.9.2.1.1CardLocationread-onlymandatory
mcmCntrShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.
1.3.6.1.4.1.4253.2.1.9.2.1.2CardShelfread-onlymandatory
mcmCntrSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 21. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.
1.3.6.1.4.1.4253.2.1.9.2.1.3CardSlotread-onlymandatory
mcmCntrType
OBJECT-TYPE
The type of the software counter data in this row. The data is collected for the SPI data channels.
1.3.6.1.4.1.4253.2.1.9.2.1.4INTEGER {spi(1), iwm(2)}read-onlymandatory
mcmCounterFlag
OBJECT-TYPE
Turns software counters On or Off for this mcmt1/mcme1.
1.3.6.1.4.1.4253.2.1.9.2.1.5FlagTyperead-writemandatory
mcmTotPktSent
OBJECT-TYPE
The number of data packets sent over the given data channel.
1.3.6.1.4.1.4253.2.1.9.2.1.6Counterread-onlymandatory
mcmTotPktRcvd
OBJECT-TYPE
The number of data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.9.2.1.7Counterread-onlymandatory
mcmBadPktRcvd
OBJECT-TYPE
The number of bad data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.9.2.1.8Counterread-onlymandatory
mcmTotBadTrans
OBJECT-TYPE
The number of bad data transmissions over the given data channel.
1.3.6.1.4.1.4253.2.1.9.2.1.9Counterread-onlymandatory
mcmBytesSent
OBJECT-TYPE
Total number of bytes sent over the given data channel.
1.3.6.1.4.1.4253.2.1.9.2.1.10Counterread-onlymandatory
mcmBytesRcvd
OBJECT-TYPE
Total number of data bytes received over the given data channel.
1.3.6.1.4.1.4253.2.1.9.2.1.11Counterread-onlymandatory
mcmMsgsDlvrd
OBJECT-TYPE
The number of complete messages delivered over the given data channel.
1.3.6.1.4.1.4253.2.1.9.2.1.12Counterread-onlymandatory
mcmBufAllocFail
OBJECT-TYPE
Number of buffer allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.1.9.2.1.13Counterread-onlymandatory
mcmEcbAllocFail
OBJECT-TYPE
Number of Event Control Block allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.1.9.2.1.14Counterread-onlymandatory
mcmClearCntrs
OBJECT-TYPE
If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other
1.3.6.1.4.1.4253.2.1.9.2.1.15ResetTyperead-writemandatory
mcmPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each mcmt1/mcme1 card
1.3.6.1.4.1.4253.2.1.9.3not-accessiblemandatory
mcmPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.9.3.1not-accessiblemandatory
mcmPerfLocation
OBJECT-TYPE
The location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) mcmt1/mcme1 cards.
1.3.6.1.4.1.4253.2.1.9.3.1.1CardLocationread-onlymandatory
mcmPerfShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 3
1.3.6.1.4.1.4253.2.1.9.3.1.2CardShelfread-onlymandatory
mcmPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 21
1.3.6.1.4.1.4253.2.1.9.3.1.3CardSlotread-onlymandatory
mcmPerfState
OBJECT-TYPE
The state of the mcmt1/mcme1 card. The states' are: online, offline, empty, loopback or diagnostics.
1.3.6.1.4.1.4253.2.1.9.3.1.4CardStateread-onlymandatory
mcmPerfStatus
OBJECT-TYPE
The status of the channel card. This status represents the status of the communication processor and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.9.3.1.5CardStatusread-onlymandatory
mcmLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.1.9.3.1.6DateAndTimeread-onlymandatory
mcmAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this mcmt1/mcme1 has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.9.3.1.7Counterread-onlymandatory
mcmErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this mcmt1/mcme1 has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.9.3.1.8Counterread-onlymandatory
mcmBiasCurrent
OBJECT-TYPE
Bias current for the optical laser. This value can be set remotely
1.3.6.1.4.1.4253.2.1.9.3.1.9INTEGERread-onlymandatory
mcmModulation
OBJECT-TYPE
The frequency modulation for the optical laser. This value can be adjusted remotely.
1.3.6.1.4.1.4253.2.1.9.3.1.10INTEGERread-onlymandatory
mcmApc
OBJECT-TYPE
The APC value. This value can be set remotely.
1.3.6.1.4.1.4253.2.1.9.3.1.11INTEGERread-onlymandatory
mcmIwmModulation
OBJECT-TYPE
The frequency modulation for the IWM channel. This value can be adjusted remotely.
1.3.6.1.4.1.4253.2.1.9.3.1.12INTEGERread-onlymandatory
mcmLaserOnOff
OBJECT-TYPE
The laser On/Off flag. This value can be set remotely.
1.3.6.1.4.1.4253.2.1.9.3.1.13FlagTyperead-onlymandatory
mcmTemperature
OBJECT-TYPE
The current temperature, or the operating temperature of the optical device.
1.3.6.1.4.1.4253.2.1.9.3.1.14Gaugeread-onlymandatory
mcmIntensity
OBJECT-TYPE
The intensity of the optical light. This value can be set remotely.
1.3.6.1.4.1.4253.2.1.9.3.1.15Gaugeread-onlymandatory
mcmSignalStrength
OBJECT-TYPE
The current signal strength for the optical path.
1.3.6.1.4.1.4253.2.1.9.3.1.16Gaugeread-onlymandatory
mcmLossOfLight
OBJECT-TYPE
If set to true, no laser light is present. If set to false, no loss of light has occurred.
1.3.6.1.4.1.4253.2.1.9.3.1.17Booleanread-onlymandatory
mcmSignalDetect
OBJECT-TYPE
If set to true, signal is detected. If set to false, no signal is present.
1.3.6.1.4.1.4253.2.1.9.3.1.18Booleanread-onlymandatory
mcmPortCurrTable
OBJECT-TYPE
This table represents the information for each MCMT1/MCME1 port's current counters.
1.3.6.1.4.1.4253.2.1.9.4not-accessiblemandatory
mcmPortCurrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.9.4.1not-accessiblemandatory
mcmPortCurrCardLocation
OBJECT-TYPE
Location of the MCMT1/MCME1 port. Valid values are: Local in the same chassis, or remote to this chassis
1.3.6.1.4.1.4253.2.1.9.4.1.1CardLocationread-onlymandatory
mcmPortCurrCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 2..3.
1.3.6.1.4.1.4253.2.1.9.4.1.2CardShelfread-onlymandatory
mcmPortCurrCardSlot
OBJECT-TYPE
The slot within the shelf the Module is in.
1.3.6.1.4.1.4253.2.1.9.4.1.3CardSlotread-onlymandatory
mcmPortCurrIndex
OBJECT-TYPE
Port's index.
1.3.6.1.4.1.4253.2.1.9.4.1.4INTEGERread-onlymandatory
mcmPortCurrASs
OBJECT-TYPE
MCMT1/MCME1 port's ASs counter less than 15 mins.
1.3.6.1.4.1.4253.2.1.9.4.1.5Counterread-onlymandatory
mcmPortCurrFrameASs
OBJECT-TYPE
MCMT1/MCME1 port's FrameASs counter less than 15 mins.
1.3.6.1.4.1.4253.2.1.9.4.1.6Counternot-accessiblemandatory
mcmPortCurrFEs
OBJECT-TYPE
MCMT1/MCME1 port's FEs counter less than 15 mins.
1.3.6.1.4.1.4253.2.1.9.4.1.7Counterread-onlymandatory
mcmPortCurrCRCErrs
OBJECT-TYPE
MCMT1/MCME1 port's CRC errs counter less than 15 mins.
1.3.6.1.4.1.4253.2.1.9.4.1.8Counterread-onlymandatory
mcmPortCurrSESs
OBJECT-TYPE
MCMT1/MCME1 port's SESs counter less than 15 mins.
1.3.6.1.4.1.4253.2.1.9.4.1.9Counterread-onlymandatory
mcmPortCurrSEFSs
OBJECT-TYPE
MCMT1/MCME1 port's SEFSs counter less than 15 mins.
1.3.6.1.4.1.4253.2.1.9.4.1.10Counterread-onlymandatory
mcmPortCurrUASs
OBJECT-TYPE
MCMT1/MCME1 port's UASs counter less than 15 mins.
1.3.6.1.4.1.4253.2.1.9.4.1.11Counterread-onlymandatory
mcmPortCurrLESs
OBJECT-TYPE
MCMT1/MCME1 port's LESs counter less than 15 mins.
1.3.6.1.4.1.4253.2.1.9.4.1.12Counterread-onlymandatory
mcmPortCurrBESs
OBJECT-TYPE
MCMT1/MCME1 port's BESs counter less than 15 mins.
1.3.6.1.4.1.4253.2.1.9.4.1.13Counterread-onlymandatory
mcmPortCurrDMs
OBJECT-TYPE
MCMT1/MCME1 port's DMSs counter less than 15 mins.
1.3.6.1.4.1.4253.2.1.9.4.1.14Counterread-onlymandatory
mcmPortCurrLCVs
OBJECT-TYPE
MCMT1/MCME1 port's LCVs counter less than 15 mins.
1.3.6.1.4.1.4253.2.1.9.4.1.15Counterread-onlymandatory
fnPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.10
fnNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all Fans in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.10.1Counterread-onlymandatory
fnPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each fan module.
1.3.6.1.4.1.4253.2.1.10.2not-accessiblemandatory
fnPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.10.2.1not-accessiblemandatory
fnPerfID
OBJECT-TYPE
The module ID where the fan module is plugged in.
1.3.6.1.4.1.4253.2.1.10.2.1.1INTEGERread-onlymandatory
fnPerfState
OBJECT-TYPE
The state of the fan module.
1.3.6.1.4.1.4253.2.1.10.2.1.2INTEGER {fnEmpty(1), fnOK(2), fnFailed(3), fnDegrade(4)}read-onlymandatory
fnPerfStatus
OBJECT-TYPE
The status of the fan module. This status represents the status of the fan module and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.10.2.1.3CardStatusread-onlymandatory
csimPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.11
csimNumEvents
OBJECT-TYPE
This variable keeps track of the number of events related to ColorSIM. The reason this has been made obsolete is that all colorsim related events would eventually be part of ocm events
1.3.6.1.4.1.4253.2.1.11.1Counternot-accessiblemandatory
csimCurrentTable
OBJECT-TYPE
This table represents the information for each colorsim card in the most current interval
1.3.6.1.4.1.4253.2.1.11.2not-accessiblemandatory
csimCurrentEntry
OBJECT-TYPE
Specifies the index for each row in the table below.
1.3.6.1.4.1.4253.2.1.11.2.1not-accessiblemandatory
csimCurrentLocation
OBJECT-TYPE
Location of the ColorSIM module
1.3.6.1.4.1.4253.2.1.11.2.1.1CardLocationread-onlymandatory
csimCurrentShelf
OBJECT-TYPE
The shelf of the ColorSIM module
1.3.6.1.4.1.4253.2.1.11.2.1.2CardShelfread-onlymandatory
csimCurrentSlot
OBJECT-TYPE
The Slot of the ColorSIM module
1.3.6.1.4.1.4253.2.1.11.2.1.3CardSlotread-onlymandatory
csimCurrentEFIs
OBJECT-TYPE
The counter associated with the number of Error Free Interval Counts in the current update (default: 15 minutes) interval.
1.3.6.1.4.1.4253.2.1.11.2.1.4INTEGERread-onlymandatory
csimCurrentEIs
OBJECT-TYPE
The counter associated with the number of Errored Interval Counts in the current update (default: 15 minutes) interval.
1.3.6.1.4.1.4253.2.1.11.2.1.5INTEGERread-onlymandatory
csimCurrentSEIs
OBJECT-TYPE
The counter associated with the number of Severly Errored Interval Counts in the current update (default:15 minutes) interval.
1.3.6.1.4.1.4253.2.1.11.2.1.6INTEGERread-onlymandatory
csimCurrentBERs
OBJECT-TYPE
The counter associated with the number of Bit Error Rates Counts in the current update (default: 15 minutes) interval. The unit will be in the form of x.ye-z.
1.3.6.1.4.1.4253.2.1.11.2.1.7DisplayStringread-onlymandatory
csimCurrentUAIs
OBJECT-TYPE
The counter associated with the number of Unavailable Interval Counts in the current update (default: 15 minutes) interval.
1.3.6.1.4.1.4253.2.1.11.2.1.8INTEGERread-onlymandatory
csimCurrentGIs
OBJECT-TYPE
The number of gating intervals over which the data was collected.
1.3.6.1.4.1.4253.2.1.11.2.1.9INTEGERread-onlymandatory
csimCurrentDateTime
OBJECT-TYPE
Time in seconds elasped since 01/01/1970 00:00:00 GMT. Assuming local time is same as GMT
1.3.6.1.4.1.4253.2.1.11.2.1.10INTEGERread-onlymandatory
rpsmPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.12
rpsmNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all RPSM's in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.12.1Counternot-accessiblemandatory
rpsmPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each rpsm card
1.3.6.1.4.1.4253.2.1.12.2not-accessiblemandatory
rpsmPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.12.2.1not-accessiblemandatory
rpsmPerfLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.1.12.2.1.1CardLocationnot-accessiblemandatory
rpsmPerfShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.1.12.2.1.2CardShelfnot-accessiblemandatory
rpsmPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.1.12.2.1.3CardSlotnot-accessiblemandatory
rpsmPerfState
OBJECT-TYPE
The state of the rpsm card. The possible states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.1.12.2.1.4CardStatenot-accessiblemandatory
rpsmPerfStatus
OBJECT-TYPE
The status of the rpsm card. This status represents the status of the rpsm card and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.12.2.1.5CardStatusnot-accessiblemandatory
rpsmLinkEastState
OBJECT-TYPE
The link state of path East, whether light is being detected. The states are: linked, notLinked.
1.3.6.1.4.1.4253.2.1.12.2.1.6INTEGER {linked(1), notLinked(2), unknown(3)}not-accessiblemandatory
rpsmLinkEastStatus
OBJECT-TYPE
The status of the card channel. This status represents the status of the link East of the card and in general is different from the status of the card.
1.3.6.1.4.1.4253.2.1.12.2.1.7INTEGER {active(1), standby(2), hibernation(3)}not-accessiblemandatory
rpsmLinkWestState
OBJECT-TYPE
The link state of path West, whether light is being detected. The states are: linked, notLinked.
1.3.6.1.4.1.4253.2.1.12.2.1.8INTEGER {linked(1), notLinked(2), unknown(3)}not-accessiblemandatory
rpsmLinkWestStatus
OBJECT-TYPE
The status of the card channel. This status represents the status of the link West of the card and in general is different from the status of the card.
1.3.6.1.4.1.4253.2.1.12.2.1.9INTEGER {active(1), standby(2), hibernation(3)}not-accessiblemandatory
rpsmLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.1.12.2.1.10DateAndTimenot-accessiblemandatory
rpsmAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this rpsm has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.12.2.1.11Counternot-accessiblemandatory
rpsmErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this rpsm has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.12.2.1.12Counternot-accessiblemandatory
rpsmWorkingPower
OBJECT-TYPE
Working link power of the RPSM card in dBm.
1.3.6.1.4.1.4253.2.1.12.2.1.13INTEGERnot-accessiblemandatory
rpsmProtectionPower
OBJECT-TYPE
Protection link power of the RPSM card in dBm.
1.3.6.1.4.1.4253.2.1.12.2.1.14INTEGERnot-accessiblemandatory
rsdmPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.13
rsdmNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all RSDM's in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.13.1Counternot-accessiblemandatory
rsdmPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each rsdm card
1.3.6.1.4.1.4253.2.1.13.2not-accessiblemandatory
rsdmPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.13.2.1not-accessiblemandatory
rsdmPerfLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.1.13.2.1.1CardLocationnot-accessiblemandatory
rsdmPerfShelf
OBJECT-TYPE
The shelf the card is in.
1.3.6.1.4.1.4253.2.1.13.2.1.2CardShelfnot-accessiblemandatory
rsdmPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.1.13.2.1.3CardSlotnot-accessiblemandatory
rsdmPerfState
OBJECT-TYPE
The state of the rsdm card. The states are: online, offline.
1.3.6.1.4.1.4253.2.1.13.2.1.4CardStatenot-accessiblemandatory
rsdmPerfStatus
OBJECT-TYPE
The status of the rsdm card. This status represents the status of the rsdm card and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.13.2.1.5CardStatusnot-accessiblemandatory
rsdmLinkEastState
OBJECT-TYPE
The link state of path A, whether light is being detected. The states are: linked, notLinked.
1.3.6.1.4.1.4253.2.1.13.2.1.6INTEGER {linked(1), notLinked(2), unknown(3)}not-accessiblemandatory
rsdmLinkEastStatus
OBJECT-TYPE
The status of the card channel. This status represents the status of the link East of the card and in general is different from the status of the card.
1.3.6.1.4.1.4253.2.1.13.2.1.7INTEGER {active(1), standby(2), hibernation(3)}not-accessiblemandatory
rsdmLinkWestState
OBJECT-TYPE
The link state of path West, whether light is being detected. The states are: linked, notLinked.
1.3.6.1.4.1.4253.2.1.13.2.1.8INTEGER {linked(1), notLinked(2), unknown(3)}not-accessiblemandatory
rsdmLinkWestStatus
OBJECT-TYPE
The status of the card channel. This status represents the status of the link West of the card and in general is different from the status of the card.
1.3.6.1.4.1.4253.2.1.13.2.1.9INTEGER {active(1), standby(2), hibernation(3)}not-accessiblemandatory
rsdmLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.1.13.2.1.10DateAndTimenot-accessiblemandatory
rsdmAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this rsdm card has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.13.2.1.11Counternot-accessiblemandatory
rsdmErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this rsdm card has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.13.2.1.12Counternot-accessiblemandatory
rsdmWorkingPower
OBJECT-TYPE
Working link power of the RSDM card in dBm.
1.3.6.1.4.1.4253.2.1.13.2.1.13INTEGERnot-accessiblemandatory
rsdmProtectionPower
OBJECT-TYPE
Protection link power of the RSDM card in dBm.
1.3.6.1.4.1.4253.2.1.13.2.1.14INTEGERnot-accessiblemandatory
rtdmPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.14
rtdmNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all RTDM's in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.14.1Counternot-accessiblemandatory
rtdmPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each rtdm card
1.3.6.1.4.1.4253.2.1.14.2not-accessiblemandatory
rtdmPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.14.2.1not-accessiblemandatory
rtdmPerfLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.1.14.2.1.1CardLocationnot-accessiblemandatory
rtdmPerfShelf
OBJECT-TYPE
The shelf the card is in.
1.3.6.1.4.1.4253.2.1.14.2.1.2CardShelfnot-accessiblemandatory
rtdmPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.1.14.2.1.3CardSlotnot-accessiblemandatory
rtdmPerfState
OBJECT-TYPE
The state of the rtdm card. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.1.14.2.1.4CardStatenot-accessiblemandatory
rtdmPerfStatus
OBJECT-TYPE
The status of the rtdm card. This status represents the status of the rtdm card and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.14.2.1.5CardStatusnot-accessiblemandatory
rtdmLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.1.14.2.1.6DateAndTimenot-accessiblemandatory
rtdmAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this rtdm has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.14.2.1.7Counternot-accessiblemandatory
rtdmErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this rtdm has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.14.2.1.8Counternot-accessiblemandatory
osamPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.15
osamNumEvents
OBJECT-TYPE
Total number of events received for all osam's in the most current 15 minutes slot.
1.3.6.1.4.1.4253.2.1.15.1Counterread-onlymandatory
osamCntrTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.1.15.2not-accessiblemandatory
osamCntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.15.2.1not-accessiblemandatory
osamCntrLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.2.1.15.2.1.1CardLocationread-onlymandatory
osamCntrShelf
OBJECT-TYPE
The shelf number in which the module is plugged in.
1.3.6.1.4.1.4253.2.1.15.2.1.2CardShelfread-onlymandatory
osamCntrSlot
OBJECT-TYPE
The slot number in which the module is plugged in.
1.3.6.1.4.1.4253.2.1.15.2.1.3INTEGER (1..16)read-onlymandatory
osamCntrKeepAlivePktSent
OBJECT-TYPE
The total number of keep alive packets sent.
1.3.6.1.4.1.4253.2.1.15.2.1.4Counterread-onlymandatory
osamCntrKeepAlivePktRcvd
OBJECT-TYPE
The total number of keep alive packets received.
1.3.6.1.4.1.4253.2.1.15.2.1.5Counterread-onlymandatory
osamCntrKeepAliveBadPktRcvd
OBJECT-TYPE
The total number of bad keep alive data packets received.
1.3.6.1.4.1.4253.2.1.15.2.1.6Counterread-onlymandatory
osamPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each osam card
1.3.6.1.4.1.4253.2.1.15.3not-accessiblemandatory
osamPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.15.3.1not-accessiblemandatory
osamPerfLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.2.1.15.3.1.1CardLocationread-onlymandatory
osamPerfShelf
OBJECT-TYPE
The shelf number in which the module is plugged in.
1.3.6.1.4.1.4253.2.1.15.3.1.2CardShelfread-onlymandatory
osamPerfSlot
OBJECT-TYPE
The slot number in which the module is plugged in.
1.3.6.1.4.1.4253.2.1.15.3.1.3INTEGER (1..16)read-onlymandatory
osamPerfState
OBJECT-TYPE
The current state of the module.
1.3.6.1.4.1.4253.2.1.15.3.1.4CardStateread-onlymandatory
osamPerfStatus
OBJECT-TYPE
The current alarm status of the channel.
1.3.6.1.4.1.4253.2.1.15.3.1.5CardStatusread-onlymandatory
osamPerfLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.1.15.3.1.6DateAndTimeread-onlymandatory
osamPerfAvailTime
OBJECT-TYPE
The number of seconds in the most current 15 minutes interval that this module has been up and running.
1.3.6.1.4.1.4253.2.1.15.3.1.7Counterread-onlymandatory
osamPerfErrFreeSecs
OBJECT-TYPE
The number of seconds in the most current 15 minutes interval that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.15.3.1.8Counterread-onlymandatory
osamPerfAprStatus
OBJECT-TYPE
The status of the automatic power reduction mode. Not applicable to OSAM-HP/LP module
1.3.6.1.4.1.4253.2.1.15.3.1.9FlagTyperead-onlymandatory
osamPerfInputPower
OBJECT-TYPE
The power at the input in dBm. Not applicable to OSAM-HP/LP module
1.3.6.1.4.1.4253.2.1.15.3.1.10DisplayStringread-onlymandatory
osamPerfBFDPower
OBJECT-TYPE
The back facet diode reading in the pump laser; related to the power output of the pump laser. This values isn't calibrated and doesn't have a unit. Not applicable to OSAM-HP/LP module
1.3.6.1.4.1.4253.2.1.15.3.1.11DisplayStringread-onlymandatory
osamPerfOutputPower
OBJECT-TYPE
The power at the output port in dBm.
1.3.6.1.4.1.4253.2.1.15.3.1.12DisplayStringread-onlymandatory
osamPerfAPRDetector1Power
OBJECT-TYPE
The automatic power reduction detector 1 reading in dBm. Two readings are provided for redundancy purposes. Not applicable to OSAM-HP/LP module
1.3.6.1.4.1.4253.2.1.15.3.1.13DisplayStringread-onlymandatory
osamPerfAPRDetector2Power
OBJECT-TYPE
The automatic power reduction detector 2 reading in dBm. Two readings are provided for redundancy purposes. Not applicable to OSAM-HP/LP module
1.3.6.1.4.1.4253.2.1.15.3.1.14DisplayStringread-onlymandatory
osamPerfLaserTemperature
OBJECT-TYPE
The pump laser temperature in degree Celsius. Not applicable to OSAM-HP/LP module
1.3.6.1.4.1.4253.2.1.15.3.1.15INTEGER (15..35)read-onlymandatory
osamPerfTecCurrent
OBJECT-TYPE
The Thermo-Electric Cooler current in mA. Not applicable to OSAM-HP/LP module
1.3.6.1.4.1.4253.2.1.15.3.1.16INTEGER (0..1500)read-onlymandatory
osamPerfBiasCurrent
OBJECT-TYPE
The measured pump laser bias current in mA. Not applicable to OSAM-HP/LP module
1.3.6.1.4.1.4253.2.1.15.3.1.17INTEGER (0..255)read-onlymandatory
osamPerfAmplifierGain
OBJECT-TYPE
The measured overall amplifier gain in dB.
1.3.6.1.4.1.4253.2.1.15.3.1.18DisplayStringread-onlymandatory
osamPerfPCBTemperature
OBJECT-TYPE
The temperature of the printed circuit board in degree Celsius.
1.3.6.1.4.1.4253.2.1.15.3.1.19INTEGER (0..75)read-onlymandatory
osam2PerfPump1BFDPower
OBJECT-TYPE
The back facet diode reading in pump 1 laser; related to the power output of the pump laser. Unit to represent the value is DAC (Digital to Analog converter)
1.3.6.1.4.1.4253.2.1.15.3.1.20INTEGERread-onlymandatory
osam2PerfPump2BFDPower
OBJECT-TYPE
The back facet diode reading in pump 2 laser; related to the power output of the pump laser. Unit to represent the value is DAC (Digital to Analog converter). Applicable only for OSAM-HP module
1.3.6.1.4.1.4253.2.1.15.3.1.21INTEGERread-onlymandatory
osam2PerfPump1IBias
OBJECT-TYPE
Indicates the bias current of Pump 1 in mA. The range of values of bias current range from 40 mA - barely turning on, to MaxIbias - maximum operating current recommended by the manufacturer. Pump IBias is used internally to set off alarms and to indicate the health of the module.
1.3.6.1.4.1.4253.2.1.15.3.1.22INTEGERread-onlymandatory
osam2PerfPump2IBias
OBJECT-TYPE
Indicates the bias current of Pump 2 in mA. The range of values of bias current range from 40 mA - barely turning on, to MaxIbias - maximum operating current recommended by the manufacturer. Pump IBias is used internally to set off alarms and to indicate the health of the module. Applicable only for OSAM-HP module
1.3.6.1.4.1.4253.2.1.15.3.1.23INTEGERread-onlymandatory
osam2PerfPump1ITEC
OBJECT-TYPE
Indicates the current level in mA of Thermal Electric Cooler (TEC) used for cooling laser pump 1.
1.3.6.1.4.1.4253.2.1.15.3.1.24INTEGERread-onlymandatory
osam2PerfPump2ITEC
OBJECT-TYPE
Indicates the current level in mA of Thermal Electric Cooler (TEC) used for cooling laser pump 2. Applicable only for OSAM-HP
1.3.6.1.4.1.4253.2.1.15.3.1.25INTEGERread-onlymandatory
osam2PerfPump1Temp
OBJECT-TYPE
Laser pump (#1) temperature in degree celcius
1.3.6.1.4.1.4253.2.1.15.3.1.26DisplayStringread-onlymandatory
osam2PerfPump2Temp
OBJECT-TYPE
Laser pump (#2) temperature in degree celcius Applicable only for OSAM-HP module
1.3.6.1.4.1.4253.2.1.15.3.1.27DisplayStringread-onlymandatory
osam2PerfGBInputPower
OBJECT-TYPE
Gain block input power in dBm.
1.3.6.1.4.1.4253.2.1.15.3.1.28DisplayStringread-onlymandatory
osam2PerfGBOutputPower
OBJECT-TYPE
Gain block output power in dBm with attenuation set to zero.
1.3.6.1.4.1.4253.2.1.15.3.1.29DisplayStringread-onlymandatory
osam2PerfAttenuation
OBJECT-TYPE
Indicates optical attenuation in dB imposed by variable optical attenuator(VOA)
1.3.6.1.4.1.4253.2.1.15.3.1.30DisplayStringread-onlymandatory
rsmPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.16
rsmNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all RSM's in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.16.1Counterread-onlymandatory
rsmPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each rsm card
1.3.6.1.4.1.4253.2.1.16.2not-accessiblemandatory
rsmPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.16.2.1not-accessiblemandatory
rsmPerfLocation
OBJECT-TYPE
The location of the card.
1.3.6.1.4.1.4253.2.1.16.2.1.1CardLocationread-onlymandatory
rsmPerfShelf
OBJECT-TYPE
The shelf the card is in.
1.3.6.1.4.1.4253.2.1.16.2.1.2CardShelfread-onlymandatory
rsmPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.1.16.2.1.3CardSlotread-onlymandatory
rsmPerfState
OBJECT-TYPE
The state of the rsm card. The possible states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.1.16.2.1.4CardStateread-onlymandatory
rsmPerfStatus
OBJECT-TYPE
The status of the rsm card. This status represents the status of the rsm card and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.16.2.1.5CardStatusread-onlymandatory
rsmLinkAState
OBJECT-TYPE
The link state of path A (East), whether light is being detected. The states are: linked, notLinked.
1.3.6.1.4.1.4253.2.1.16.2.1.6INTEGER {linked(1), notLinked(2), unknown(3)}read-onlymandatory
rsmLinkAStatus
OBJECT-TYPE
The status of the card channel. This status represents the status of the link A (East) of the card and in general is different from the status of the card.
1.3.6.1.4.1.4253.2.1.16.2.1.7INTEGER {active(1), standby(2), na(3)}read-onlymandatory
rsmLinkBState
OBJECT-TYPE
The link state of path B (West), whether light is being detected. The states are: linked, notLinked.
1.3.6.1.4.1.4253.2.1.16.2.1.8INTEGER {linked(1), notLinked(2), unknown(3)}read-onlymandatory
rsmLinkBStatus
OBJECT-TYPE
The status of the card channel. This status represents the status of the link B (West) of the card and in general is different from the status of the card.
1.3.6.1.4.1.4253.2.1.16.2.1.9INTEGER {active(1), standby(2), na(3)}read-onlymandatory
rsmLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.1.16.2.1.10DateAndTimeread-onlymandatory
rsmAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this rsm has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.16.2.1.11Counterread-onlymandatory
rsmErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this rsm has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.16.2.1.12Counterread-onlymandatory
rsmWorkingPower
OBJECT-TYPE
Working link power of the RSM card in dBm.
1.3.6.1.4.1.4253.2.1.16.2.1.13INTEGERread-onlymandatory
rsmProtectionPower
OBJECT-TYPE
Protection link power of the RSM card in dBm.
1.3.6.1.4.1.4253.2.1.16.2.1.14INTEGERread-onlymandatory
upsmPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.17
upsmNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all UPSM's in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.17.1Counterread-onlymandatory
upsmPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each upsm card
1.3.6.1.4.1.4253.2.1.17.2not-accessiblemandatory
upsmPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.17.2.1not-accessiblemandatory
upsmPerfLocation
OBJECT-TYPE
The location of the card.
1.3.6.1.4.1.4253.2.1.17.2.1.1CardLocationread-onlymandatory
upsmPerfShelf
OBJECT-TYPE
The shelf the card is in.
1.3.6.1.4.1.4253.2.1.17.2.1.2CardShelfread-onlymandatory
upsmPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.1.17.2.1.3CardSlotread-onlymandatory
upsmPerfState
OBJECT-TYPE
The state of the upsm card. The possible states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.1.17.2.1.4CardStateread-onlymandatory
upsmPerfStatus
OBJECT-TYPE
The status of the upsm card. This status represents the status of the upsm card and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.17.2.1.5CardStatusread-onlymandatory
upsmLinkAState
OBJECT-TYPE
The link state of path A (East), whether light is being detected. The states are: linked, notLinked.
1.3.6.1.4.1.4253.2.1.17.2.1.6INTEGER {linked(1), notLinked(2), unknown(3)}read-onlymandatory
upsmLinkAStatus
OBJECT-TYPE
The status of the card channel. This status represents the status of the link A (East) of the card and in general is different from the status of the card.
1.3.6.1.4.1.4253.2.1.17.2.1.7INTEGER {active(1), standby(2), hibernation(3)}read-onlymandatory
upsmLinkBState
OBJECT-TYPE
The link state of path B (West), whether light is being detected. The states are: linked, notLinked.
1.3.6.1.4.1.4253.2.1.17.2.1.8INTEGER {linked(1), notLinked(2), unknown(3)}read-onlymandatory
upsmLinkBStatus
OBJECT-TYPE
The status of the card channel. This status represents the status of the link B (West) of the card and in general is different from the status of the card.
1.3.6.1.4.1.4253.2.1.17.2.1.9INTEGER {active(1), standby(2), hibernation(3)}read-onlymandatory
upsmLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.1.17.2.1.10DateAndTimeread-onlymandatory
upsmAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this upsm has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.17.2.1.11Counterread-onlymandatory
upsmErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this upsm has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.17.2.1.12Counterread-onlymandatory
upsmWorkingPower
OBJECT-TYPE
Working link power of the UPSM card in dBm.
1.3.6.1.4.1.4253.2.1.17.2.1.13INTEGERread-onlymandatory
upsmProtectionPower
OBJECT-TYPE
Protection link power of the UPSM card in dBm.
1.3.6.1.4.1.4253.2.1.17.2.1.14INTEGERread-onlymandatory
mcmescPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.18
mcmescNumEvents
OBJECT-TYPE
Total number of events received for all mcmesc's in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.18.1Counterread-onlymandatory
mcmescCntrTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.1.18.2not-accessiblemandatory
mcmescCntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.18.2.1not-accessiblemandatory
mcmescCntrLocation
OBJECT-TYPE
The location of the mcmesc card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmesc cards.
1.3.6.1.4.1.4253.2.1.18.2.1.1CardLocationread-onlymandatory
mcmescCntrShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.
1.3.6.1.4.1.4253.2.1.18.2.1.2CardShelfread-onlymandatory
mcmescCntrSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 21. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.
1.3.6.1.4.1.4253.2.1.18.2.1.3CardSlotread-onlymandatory
mcmescCntrType
OBJECT-TYPE
The type of the software counter data in this row. The data is collected for the SPI data channels.
1.3.6.1.4.1.4253.2.1.18.2.1.4INTEGER {spi(1), iwm(2)}read-onlymandatory
mcmescCounterFlag
OBJECT-TYPE
Turns software counters On or Off for this mcmesc.
1.3.6.1.4.1.4253.2.1.18.2.1.5FlagTyperead-writemandatory
mcmescTotPktSent
OBJECT-TYPE
The number of data packets sent over the given data channel.
1.3.6.1.4.1.4253.2.1.18.2.1.6Counterread-onlymandatory
mcmescTotPktRcvd
OBJECT-TYPE
The number of data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.18.2.1.7Counterread-onlymandatory
mcmescBadPktRcvd
OBJECT-TYPE
The number of bad data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.18.2.1.8Counterread-onlymandatory
mcmescTotBadTrans
OBJECT-TYPE
The number of bad data transmissions over the given data channel.
1.3.6.1.4.1.4253.2.1.18.2.1.9Counterread-onlymandatory
mcmescBytesSent
OBJECT-TYPE
Total number of bytes sent over the given data channel.
1.3.6.1.4.1.4253.2.1.18.2.1.10Counterread-onlymandatory
mcmescBytesRcvd
OBJECT-TYPE
Total number of data bytes received over the given data channel.
1.3.6.1.4.1.4253.2.1.18.2.1.11Counterread-onlymandatory
mcmescMsgsDlvrd
OBJECT-TYPE
The number of complete messages delivered over the given data channel.
1.3.6.1.4.1.4253.2.1.18.2.1.12Counterread-onlymandatory
mcmescClearCntrs
OBJECT-TYPE
If the value is reset, all software counters are reset to zero. A get on this will always return other
1.3.6.1.4.1.4253.2.1.18.2.1.13ResetTyperead-writemandatory
mcmescPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each mcmesc card
1.3.6.1.4.1.4253.2.1.18.3not-accessiblemandatory
mcmescPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.18.3.1not-accessiblemandatory
mcmescPerfLocation
OBJECT-TYPE
The location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) mcmesc cards.
1.3.6.1.4.1.4253.2.1.18.3.1.1CardLocationread-onlymandatory
mcmescPerfShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 3
1.3.6.1.4.1.4253.2.1.18.3.1.2CardShelfread-onlymandatory
mcmescPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 21
1.3.6.1.4.1.4253.2.1.18.3.1.3CardSlotread-onlymandatory
mcmescPerfState
OBJECT-TYPE
The state of the mcmesc card. The states' are: online, offline, empty, loopback or diagnostics.
1.3.6.1.4.1.4253.2.1.18.3.1.4CardStateread-onlymandatory
mcmescPerfStatus
OBJECT-TYPE
The status of the channel card. This status represents the status of the communication processor and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.18.3.1.5CardStatusread-onlymandatory
mcmescLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.1.18.3.1.6DateAndTimeread-onlymandatory
mcmescAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this mcmesc has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.18.3.1.7Counterread-onlymandatory
mcmescPortCurrTable
OBJECT-TYPE
This table represents the information for each mcmesc cpe port's current counters.
1.3.6.1.4.1.4253.2.1.18.4not-accessiblemandatory
mcmescPortCurrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.18.4.1not-accessiblemandatory
mcmescPortCurrCardLocation
OBJECT-TYPE
Location of the MCMESC CPE port. Valid values are: Local in the same chassis, or remote to this chassis
1.3.6.1.4.1.4253.2.1.18.4.1.1CardLocationread-onlymandatory
mcmescPortCurrCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 2..3.
1.3.6.1.4.1.4253.2.1.18.4.1.2CardShelfread-onlymandatory
mcmescPortCurrCardSlot
OBJECT-TYPE
The slot within the shelf the Module is in.
1.3.6.1.4.1.4253.2.1.18.4.1.3CardSlotread-onlymandatory
mcmescPortCurrPort
OBJECT-TYPE
CPE port's index.
1.3.6.1.4.1.4253.2.1.18.4.1.4INTEGERread-onlymandatory
mcmescPortCurrRxSig
OBJECT-TYPE
CPE port's receive signal power.
1.3.6.1.4.1.4253.2.1.18.4.1.5DisplayString (SIZE(0..10))read-onlymandatory
mcmescPortCurrDuration
OBJECT-TYPE
mcmesc CPE port's current ongoing interval duration.
1.3.6.1.4.1.4253.2.1.18.4.1.6DisplayStringread-onlymandatory
mcmescPortCurrEns
OBJECT-TYPE
mcmesc CPE port's enabled seconds during current ongoing interval.
1.3.6.1.4.1.4253.2.1.18.4.1.7DisplayStringread-onlymandatory
mcmescPortCurrLoss
OBJECT-TYPE
mcmesc CPE port's loss of signal seconds during current ongoing interval.
1.3.6.1.4.1.4253.2.1.18.4.1.8DisplayStringread-onlymandatory
mcmescPortCurrCrcErr
OBJECT-TYPE
mcmesc CPE port's CRC error counter during current ongoing interval.
1.3.6.1.4.1.4253.2.1.18.4.1.9DisplayStringread-onlymandatory
mcmescPortCurrOobErr
OBJECT-TYPE
mcmesc CPE port's Out-Of_Band error counter during current ongoing interval.
1.3.6.1.4.1.4253.2.1.18.4.1.10DisplayStringread-onlymandatory
mcmescPortCurrRdpErr
OBJECT-TYPE
mcmesc CPE port's Running Disparity error counter during current ongoing interval.
1.3.6.1.4.1.4253.2.1.18.4.1.11DisplayStringread-onlymandatory
mcmescPortCurrBer
OBJECT-TYPE
mcmesc CPE port's BER, in the form of x.yE-z.
1.3.6.1.4.1.4253.2.1.18.4.1.12DisplayStringread-onlymandatory
mcmescLinkCurrTable
OBJECT-TYPE
This table represents the information for each mcmesc cpe port's current counters.
1.3.6.1.4.1.4253.2.1.18.5not-accessiblemandatory
mcmescLinkCurrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.18.5.1not-accessiblemandatory
mcmescLinkCurrCardLocation
OBJECT-TYPE
Location of the MCMESC CPE port. Valid values are: Local in the same chassis, or remote to this chassis
1.3.6.1.4.1.4253.2.1.18.5.1.1CardLocationread-onlymandatory
mcmescLinkCurrCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 2..3.
1.3.6.1.4.1.4253.2.1.18.5.1.2CardShelfread-onlymandatory
mcmescLinkCurrCardSlot
OBJECT-TYPE
The slot within the shelf the Module is in.
1.3.6.1.4.1.4253.2.1.18.5.1.3CardSlotread-onlymandatory
mcmescLinkCurrRxSig
OBJECT-TYPE
Link port's receive signal power.
1.3.6.1.4.1.4253.2.1.18.5.1.4DisplayString (SIZE(0..10))read-onlymandatory
mcmescLinkCurrDuration
OBJECT-TYPE
mcmesc LINK port's current ongoing interval duration.
1.3.6.1.4.1.4253.2.1.18.5.1.5DisplayStringread-onlymandatory
mcmescLinkCurrTsos
OBJECT-TYPE
mcmesc LINK port's test-sequence on seconds during current ongoing interval.
1.3.6.1.4.1.4253.2.1.18.5.1.6DisplayStringread-onlymandatory
mcmescLinkCurrLoss
OBJECT-TYPE
mcmesc LINK port's loss of signal seconds during current ongoing interval.
1.3.6.1.4.1.4253.2.1.18.5.1.7DisplayStringread-onlymandatory
mcmescLinkCurrCrcErr
OBJECT-TYPE
mcmesc LINK port's CRC error counter during current ongoing interval.
1.3.6.1.4.1.4253.2.1.18.5.1.8DisplayStringread-onlymandatory
mcmescLinkCurrOobErr
OBJECT-TYPE
mcmesc LINK port's Out-Of_Band error counter during current ongoing interval.
1.3.6.1.4.1.4253.2.1.18.5.1.9DisplayStringread-onlymandatory
mcmescLinkCurrRdpErr
OBJECT-TYPE
mcmesc LINK port's Running Disparity error counter during current ongoing interval.
1.3.6.1.4.1.4253.2.1.18.5.1.10DisplayStringread-onlymandatory
mcmescLinkCurrBer
OBJECT-TYPE
mcmesc LINK port's BER, in the form of x.yE-z.
1.3.6.1.4.1.4253.2.1.18.5.1.11DisplayStringread-onlymandatory
routingPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.21
imnRoutingPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each route
1.3.6.1.4.1.4253.2.1.21.1not-accessiblemandatory
imnRoutingPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.21.1.1not-accessiblemandatory
imnRoutePerfIpDest
OBJECT-TYPE
Destination IP address. Not supported for remote TMM masters.
1.3.6.1.4.1.4253.2.1.21.1.1.1IpAddressread-onlymandatory
imnRoutePerfStatus
OBJECT-TYPE
Is the route active, comatose or dead
1.3.6.1.4.1.4253.2.1.21.1.1.2INTEGER {dead(1), comatose(2), active(3)}read-onlymandatory
tapPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.22
tapNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all TAP modules in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.22.1Counterread-onlymandatory
tapPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each TAP module.
1.3.6.1.4.1.4253.2.1.22.2not-accessiblemandatory
tapPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.22.2.1not-accessiblemandatory
tapPerfLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.1.22.2.1.1CardLocationread-onlymandatory
tapPerfShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.1.22.2.1.2CardShelfread-onlymandatory
tapPerfSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.1.22.2.1.3CardSlotread-onlymandatory
tapType
OBJECT-TYPE
Module type.
1.3.6.1.4.1.4253.2.1.22.2.1.4CardTyperead-onlymandatory
tapPerfState
OBJECT-TYPE
The state of the TAP module. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.1.22.2.1.5CardStateread-onlymandatory
tapPerfStatus
OBJECT-TYPE
The status of the TAP module. This status represents the status of the TAP module and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.22.2.1.6CardStatusread-onlymandatory
tapLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.1.22.2.1.7DateAndTimeread-onlymandatory
tapAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.22.2.1.8Counterread-onlymandatory
tapErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.22.2.1.9Counterread-onlymandatory
voadmPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.23
voadmNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all VOADM modules in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.23.1Counterread-onlymandatory
voadmPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each VOADM module.
1.3.6.1.4.1.4253.2.1.23.2not-accessiblemandatory
voadmPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.23.2.1not-accessiblemandatory
voadmPerfLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.1.23.2.1.1CardLocationread-onlymandatory
voadmPerfShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.1.23.2.1.2CardShelfread-onlymandatory
voadmPerfSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.1.23.2.1.3CardSlotread-onlymandatory
voadmType
OBJECT-TYPE
Module type.
1.3.6.1.4.1.4253.2.1.23.2.1.4CardTyperead-onlymandatory
voadmPerfState
OBJECT-TYPE
The state of the VOADM module. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.1.23.2.1.5CardStateread-onlymandatory
voadmPerfStatus
OBJECT-TYPE
The status of the VOADM module. This status represents the status of the VOADM module and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.23.2.1.6CardStatusread-onlymandatory
voadmLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.1.23.2.1.7DateAndTimeread-onlymandatory
voadmAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.23.2.1.8Counterread-onlymandatory
voadmErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.23.2.1.9Counterread-onlymandatory
dmmPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.24
dmmNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all DMM modules in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.24.1Counterread-onlymandatory
dmmPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each DMM module.
1.3.6.1.4.1.4253.2.1.24.2not-accessiblemandatory
dmmPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.24.2.1not-accessiblemandatory
dmmPerfLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.1.24.2.1.1CardLocationread-onlymandatory
dmmPerfShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.1.24.2.1.2CardShelfread-onlymandatory
dmmPerfSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.1.24.2.1.3CardSlotread-onlymandatory
dmmPerfState
OBJECT-TYPE
The state of the DMM module. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.1.24.2.1.4CardStateread-onlymandatory
dmmPerfStatus
OBJECT-TYPE
The status of the DMM module. This status represents the status of the DMM module and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.24.2.1.5CardStatusread-onlymandatory
dmmLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.1.24.2.1.6DateAndTimeread-onlymandatory
dmmAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.24.2.1.7Counterread-onlymandatory
dmmErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.24.2.1.8Counterread-onlymandatory
dmmCntrTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.1.24.3not-accessiblemandatory
dmmCntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.24.3.1not-accessiblemandatory
dmmCntrLocation
OBJECT-TYPE
The location of the DMM card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known DMM cards.
1.3.6.1.4.1.4253.2.1.24.3.1.1CardLocationread-onlymandatory
dmmCntrShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) DMM cards.
1.3.6.1.4.1.4253.2.1.24.3.1.2CardShelfread-onlymandatory
dmmCntrSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) DMM cards.
1.3.6.1.4.1.4253.2.1.24.3.1.3CardSlotread-onlymandatory
dmmCntrType
OBJECT-TYPE
The type of the software counter data in this row.
1.3.6.1.4.1.4253.2.1.24.3.1.4INTEGER {spi(1), ibm(2), hdlc(3)}read-onlymandatory
dmmTotPktSent
OBJECT-TYPE
The number of data packets sent over the given data channel.
1.3.6.1.4.1.4253.2.1.24.3.1.5Counterread-onlymandatory
dmmTotPktRcvd
OBJECT-TYPE
The number of data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.24.3.1.6Counterread-onlymandatory
dmmTotBadTrans
OBJECT-TYPE
The number of bad data transmissions over the given data channel.
1.3.6.1.4.1.4253.2.1.24.3.1.7Counterread-onlymandatory
dmmBadPktRcvd
OBJECT-TYPE
The number of bad data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.24.3.1.8Counterread-onlymandatory
dmmBytesSent
OBJECT-TYPE
Total number of bytes sent over the given data channel.
1.3.6.1.4.1.4253.2.1.24.3.1.9Counterread-onlymandatory
dmmBytesRcvd
OBJECT-TYPE
Total number of data bytes received over the given data channel.
1.3.6.1.4.1.4253.2.1.24.3.1.10Counterread-onlymandatory
dmmMsgsDlvrd
OBJECT-TYPE
The number of complete messages delivered over the given data channel.
1.3.6.1.4.1.4253.2.1.24.3.1.11Counterread-onlymandatory
dmmClearCntrs
OBJECT-TYPE
If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other
1.3.6.1.4.1.4253.2.1.24.3.1.12ResetTyperead-writemandatory
dmmPmTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.1.24.4not-accessiblemandatory
dmmPmEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.24.4.1not-accessiblemandatory
dmmPmLocation
OBJECT-TYPE
The location of the DMM card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known DMM cards.
1.3.6.1.4.1.4253.2.1.24.4.1.1CardLocationread-onlymandatory
dmmPmShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) DMM cards.
1.3.6.1.4.1.4253.2.1.24.4.1.2CardShelfread-onlymandatory
dmmPmSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) DMM cards.
1.3.6.1.4.1.4253.2.1.24.4.1.3CardSlotread-onlymandatory
dmmPmType
OBJECT-TYPE
The type of the software counter data in this row.
1.3.6.1.4.1.4253.2.1.24.4.1.4INTEGER {link(1), port1(2), port2(3)}read-onlymandatory
dmmPmErrors
OBJECT-TYPE
The number of packets errors since port last came online.
1.3.6.1.4.1.4253.2.1.24.4.1.5Counterread-onlymandatory
dmmPmErredSecs
OBJECT-TYPE
The number of erred seconds since port last came online.
1.3.6.1.4.1.4253.2.1.24.4.1.6Counterread-onlymandatory
dmmStartTime
OBJECT-TYPE
The date/time the port came last online.
1.3.6.1.4.1.4253.2.1.24.4.1.7DateAndTimeread-onlymandatory
dmmClearPmCntrs
OBJECT-TYPE
If the value is reset, all PM counters for this port are reset to zero. A get on this will always return other
1.3.6.1.4.1.4253.2.1.24.4.1.8ResetTyperead-writemandatory
dmmPmRxPower
OBJECT-TYPE
Port receive power.
1.3.6.1.4.1.4253.2.1.24.4.1.9DisplayStringread-onlymandatory
dmmPmTxPower
OBJECT-TYPE
Port receive power.
1.3.6.1.4.1.4253.2.1.24.4.1.10DisplayStringread-onlymandatory
ocm10gfPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.25
ocm10gfNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all OCM10GF modules in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.25.1Counterread-onlymandatory
ocm10gfPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each OCM10GF module.
1.3.6.1.4.1.4253.2.1.25.2not-accessiblemandatory
ocm10gfPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.25.2.1not-accessiblemandatory
ocm10gfPerfLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.1.25.2.1.1CardLocationread-onlymandatory
ocm10gfPerfShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.1.25.2.1.2CardShelfread-onlymandatory
ocm10gfPerfSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.1.25.2.1.3CardSlotread-onlymandatory
ocm10gfPerfState
OBJECT-TYPE
The state of the OCM10GF module. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.1.25.2.1.4CardStateread-onlymandatory
ocm10gfPerfStatus
OBJECT-TYPE
The status of the OCM10GF module. This status represents the status of the OCM10GF module and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.25.2.1.5CardStatusread-onlymandatory
ocm10gfLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.1.25.2.1.6DateAndTimeread-onlymandatory
ocm10gfAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.25.2.1.7Counterread-onlymandatory
ocm10gfErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.25.2.1.8Counterread-onlymandatory
ocm10gfCntrTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.1.25.3not-accessiblemandatory
ocm10gfCntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.25.3.1not-accessiblemandatory
ocm10gfCntrLocation
OBJECT-TYPE
The location of the OCM10GF card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM10GF cards.
1.3.6.1.4.1.4253.2.1.25.3.1.1CardLocationread-onlymandatory
ocm10gfCntrShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM10GF cards.
1.3.6.1.4.1.4253.2.1.25.3.1.2CardShelfread-onlymandatory
ocm10gfCntrSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM10GF cards.
1.3.6.1.4.1.4253.2.1.25.3.1.3CardSlotread-onlymandatory
ocm10gfCntrType
OBJECT-TYPE
The type of the software counter data in this row.
1.3.6.1.4.1.4253.2.1.25.3.1.4INTEGER {spi(1), ibm(2), hdlc(3)}read-onlymandatory
ocm10gfTotPktSent
OBJECT-TYPE
The number of data packets sent over the given data channel.
1.3.6.1.4.1.4253.2.1.25.3.1.5Counterread-onlymandatory
ocm10gfTotPktRcvd
OBJECT-TYPE
The number of data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.25.3.1.6Counterread-onlymandatory
ocm10gfTotBadTrans
OBJECT-TYPE
The number of bad data transmissions over the given data channel.
1.3.6.1.4.1.4253.2.1.25.3.1.7Counterread-onlymandatory
ocm10gfBadPktRcvd
OBJECT-TYPE
The number of bad data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.25.3.1.8Counterread-onlymandatory
ocm10gfBytesSent
OBJECT-TYPE
Total number of bytes sent over the given data channel.
1.3.6.1.4.1.4253.2.1.25.3.1.9Counterread-onlymandatory
ocm10gfBytesRcvd
OBJECT-TYPE
Total number of data bytes received over the given data channel.
1.3.6.1.4.1.4253.2.1.25.3.1.10Counterread-onlymandatory
ocm10gfMsgsDlvrd
OBJECT-TYPE
The number of complete messages delivered over the given data channel.
1.3.6.1.4.1.4253.2.1.25.3.1.11Counterread-onlymandatory
ocm10gfClearCntrs
OBJECT-TYPE
If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other
1.3.6.1.4.1.4253.2.1.25.3.1.12ResetTyperead-writemandatory
ocm10gfPmTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.1.25.4not-accessiblemandatory
ocm10gfPmEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.25.4.1not-accessiblemandatory
ocm10gfPmLocation
OBJECT-TYPE
The location of the OCM10GF card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM10GF cards.
1.3.6.1.4.1.4253.2.1.25.4.1.1CardLocationread-onlymandatory
ocm10gfPmShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM10GF cards.
1.3.6.1.4.1.4253.2.1.25.4.1.2CardShelfread-onlymandatory
ocm10gfPmSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM10GF cards.
1.3.6.1.4.1.4253.2.1.25.4.1.3CardSlotread-onlymandatory
ocm10gfPmNumIntervals
OBJECT-TYPE
1.3.6.1.4.1.4253.2.1.25.4.1.4INTEGERread-onlymandatory
ocm10gfPmLinkRxPwr
OBJECT-TYPE
1.3.6.1.4.1.4253.2.1.25.4.1.5DisplayStringread-onlymandatory
ocm10gfPmLinkTxPwr
OBJECT-TYPE
1.3.6.1.4.1.4253.2.1.25.4.1.6DisplayStringread-onlymandatory
ocm10gfPmLinkFecErrors
OBJECT-TYPE
1.3.6.1.4.1.4253.2.1.25.4.1.7DisplayStringread-onlymandatory
ocm10gfPmLinkUncorrectedFecErrs
OBJECT-TYPE
1.3.6.1.4.1.4253.2.1.25.4.1.8Counterread-onlymandatory
ocm10gfPmLinkCorrectedFecErrs
OBJECT-TYPE
1.3.6.1.4.1.4253.2.1.25.4.1.9DisplayStringread-onlymandatory
ocm10gfPmLinkCorrectedOnesErr
OBJECT-TYPE
1.3.6.1.4.1.4253.2.1.25.4.1.10DisplayStringread-onlymandatory
ocm10gfPmLinkErredSeconds
OBJECT-TYPE
1.3.6.1.4.1.4253.2.1.25.4.1.11Counterread-onlymandatory
ocm10gfPmCpeRxPwr
OBJECT-TYPE
1.3.6.1.4.1.4253.2.1.25.4.1.12DisplayStringread-onlymandatory
ocm10gfPmCpeTxPwr
OBJECT-TYPE
1.3.6.1.4.1.4253.2.1.25.4.1.13DisplayStringread-onlymandatory
ocm10gfPmCpeSonetRxB2Errs
OBJECT-TYPE
1.3.6.1.4.1.4253.2.1.25.4.1.14DisplayStringread-onlymandatory
ocm10gfPmCpeSonetTxB2Errs
OBJECT-TYPE
1.3.6.1.4.1.4253.2.1.25.4.1.15DisplayStringread-onlymandatory
ocm10gfPmCpe10GbeRxTotalPkts
OBJECT-TYPE
1.3.6.1.4.1.4253.2.1.25.4.1.16DisplayStringread-onlymandatory
ocm10gfPmCpe10GbeRxErredPkts
OBJECT-TYPE
1.3.6.1.4.1.4253.2.1.25.4.1.17DisplayStringread-onlymandatory
ocm10gfPmCpe10GbeTxTotalPkts
OBJECT-TYPE
1.3.6.1.4.1.4253.2.1.25.4.1.18DisplayStringread-onlymandatory
ocm10gfPmCpe10gbeTxErredPkts
OBJECT-TYPE
1.3.6.1.4.1.4253.2.1.25.4.1.19DisplayStringread-onlymandatory
ocm10gfPmCpeErredSeconds
OBJECT-TYPE
1.3.6.1.4.1.4253.2.1.25.4.1.20Counterread-onlymandatory
ocm10gfClearPmCntrs
OBJECT-TYPE
If the value is reset, all PM counters for this port are reset to zero. A get on this will always return other
1.3.6.1.4.1.4253.2.1.25.4.1.21ResetTyperead-writemandatory
ocm2Perf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.26
ocm2NumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all OCM2 modules in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.26.1Counterread-onlymandatory
ocm2PerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each OCM2 module.
1.3.6.1.4.1.4253.2.1.26.2not-accessiblemandatory
ocm2PerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.26.2.1not-accessiblemandatory
ocm2PerfLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.1.26.2.1.1CardLocationread-onlymandatory
ocm2PerfShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.1.26.2.1.2CardShelfread-onlymandatory
ocm2PerfSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.1.26.2.1.3CardSlotread-onlymandatory
ocm2PerfState
OBJECT-TYPE
The state of the OCM2 module. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.1.26.2.1.4CardStateread-onlymandatory
ocm2PerfStatus
OBJECT-TYPE
The status of the OCM2 module. This status represents the status of the OCM2 module and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.26.2.1.5CardStatusread-onlymandatory
ocm2LastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.1.26.2.1.6DateAndTimeread-onlymandatory
ocm2AvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.26.2.1.7Counterread-onlymandatory
ocm2ErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.26.2.1.8Counterread-onlymandatory
ocm2CntrTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.1.26.3not-accessiblemandatory
ocm2CntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.26.3.1not-accessiblemandatory
ocm2CntrLocation
OBJECT-TYPE
The location of the OCM2 card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM2 cards.
1.3.6.1.4.1.4253.2.1.26.3.1.1CardLocationread-onlymandatory
ocm2CntrShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM2 cards.
1.3.6.1.4.1.4253.2.1.26.3.1.2CardShelfread-onlymandatory
ocm2CntrSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM2 cards.
1.3.6.1.4.1.4253.2.1.26.3.1.3CardSlotread-onlymandatory
ocm2CntrType
OBJECT-TYPE
The type of the software counter data in this row.
1.3.6.1.4.1.4253.2.1.26.3.1.4INTEGER {spi(1), ibm1(2), ibm2(3), hdlc(4)}read-onlymandatory
ocm2TotPktSent
OBJECT-TYPE
The number of data packets sent over the given data channel.
1.3.6.1.4.1.4253.2.1.26.3.1.5Counterread-onlymandatory
ocm2TotPktRcvd
OBJECT-TYPE
The number of data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.26.3.1.6Counterread-onlymandatory
ocm2TotBadTrans
OBJECT-TYPE
The number of bad data transmissions over the given data channel.
1.3.6.1.4.1.4253.2.1.26.3.1.7Counterread-onlymandatory
ocm2BadPktRcvd
OBJECT-TYPE
The number of bad data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.26.3.1.8Counterread-onlymandatory
ocm2BytesSent
OBJECT-TYPE
Total number of bytes sent over the given data channel.
1.3.6.1.4.1.4253.2.1.26.3.1.9Counterread-onlymandatory
ocm2BytesRcvd
OBJECT-TYPE
Total number of data bytes received over the given data channel.
1.3.6.1.4.1.4253.2.1.26.3.1.10Counterread-onlymandatory
ocm2MsgsDlvrd
OBJECT-TYPE
The number of complete messages delivered over the given data channel.
1.3.6.1.4.1.4253.2.1.26.3.1.11Counterread-onlymandatory
ocm2ClearCntrs
OBJECT-TYPE
If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other
1.3.6.1.4.1.4253.2.1.26.3.1.12ResetTyperead-writemandatory
ocm2PmTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.1.26.4not-accessiblemandatory
ocm2PmEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.26.4.1not-accessiblemandatory
ocm2PmLocation
OBJECT-TYPE
The location of the OCM2 card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM2 cards.
1.3.6.1.4.1.4253.2.1.26.4.1.1CardLocationread-onlymandatory
ocm2PmShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM2 cards.
1.3.6.1.4.1.4253.2.1.26.4.1.2CardShelfread-onlymandatory
ocm2PmSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM2 cards.
1.3.6.1.4.1.4253.2.1.26.4.1.3CardSlotread-onlymandatory
ocm2PmLinkRxPwr
OBJECT-TYPE
Link receive power.
1.3.6.1.4.1.4253.2.1.26.4.1.5DisplayStringread-onlymandatory
ocm2PmLinkTxPwr
OBJECT-TYPE
Link transmit power.
1.3.6.1.4.1.4253.2.1.26.4.1.6DisplayStringread-onlymandatory
ocm2PmCpeRxPwr
OBJECT-TYPE
CPE receive power.
1.3.6.1.4.1.4253.2.1.26.4.1.7DisplayStringread-onlymandatory
ocm2PmCpeTxPwr
OBJECT-TYPE
CPE transmit power.
1.3.6.1.4.1.4253.2.1.26.4.1.8DisplayStringread-onlymandatory
ocm2PmNumLinkRxIntervals
OBJECT-TYPE
The of intervals (seconds) over which the link Rx statistics have been accumulated.
1.3.6.1.4.1.4253.2.1.26.4.1.9INTEGERread-onlymandatory
ocm2PmLinkRxErrors
OBJECT-TYPE
Link receive errors.
1.3.6.1.4.1.4253.2.1.26.4.1.10DisplayStringread-onlymandatory
ocm2PmLinkRxErredSeconds
OBJECT-TYPE
Link receive errored seconds.
1.3.6.1.4.1.4253.2.1.26.4.1.11Counterread-onlymandatory
ocm2PmNumCpeRxIntervals
OBJECT-TYPE
The of intervals (seconds) over which the CPE Rx statistics have been accumulated.
1.3.6.1.4.1.4253.2.1.26.4.1.12INTEGERread-onlymandatory
ocm2PmCpeRxErrors
OBJECT-TYPE
CPE receive errors.
1.3.6.1.4.1.4253.2.1.26.4.1.13DisplayStringread-onlymandatory
ocm2PmCpeRxErredSeconds
OBJECT-TYPE
CPE receive errored seconds.
1.3.6.1.4.1.4253.2.1.26.4.1.14Counterread-onlymandatory
ocm2PmNumCpeTxIntervals
OBJECT-TYPE
The of intervals (seconds) over which the CPE Tx statistics have been accumulated.
1.3.6.1.4.1.4253.2.1.26.4.1.15INTEGERread-onlymandatory
ocm2PmCpeTxErrors
OBJECT-TYPE
CPE transmit errors.
1.3.6.1.4.1.4253.2.1.26.4.1.16DisplayStringread-onlymandatory
ocm2PmCpeTxErredSeconds
OBJECT-TYPE
CPE transmit errored seconds.
1.3.6.1.4.1.4253.2.1.26.4.1.17Counterread-onlymandatory
ocm2ClearPmCntrs
OBJECT-TYPE
If the value is reset, all PM counters for this port are reset to zero. A get on this will always return other
1.3.6.1.4.1.4253.2.1.26.4.1.18ResetTyperead-writemandatory
oscPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.27
oscNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all OSC modules in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.27.1Counterread-onlymandatory
oscPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each OSC module.
1.3.6.1.4.1.4253.2.1.27.2not-accessiblemandatory
oscPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.27.2.1not-accessiblemandatory
oscPerfLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.1.27.2.1.1CardLocationread-onlymandatory
oscPerfShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.1.27.2.1.2CardShelfread-onlymandatory
oscPerfSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.1.27.2.1.3CardSlotread-onlymandatory
oscPerfState
OBJECT-TYPE
The state of the OSC module. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.1.27.2.1.4CardStateread-onlymandatory
oscPerfStatus
OBJECT-TYPE
The status of the OSC module. This status represents the status of the OSC module and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.27.2.1.5CardStatusread-onlymandatory
oscLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.1.27.2.1.6DateAndTimeread-onlymandatory
oscAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.27.2.1.7Counterread-onlymandatory
oscErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.27.2.1.8Counterread-onlymandatory
oscCntrTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.1.27.3not-accessiblemandatory
oscCntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.27.3.1not-accessiblemandatory
oscCntrLocation
OBJECT-TYPE
The location of the OSC card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OSC cards.
1.3.6.1.4.1.4253.2.1.27.3.1.1CardLocationread-onlymandatory
oscCntrShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OSC cards.
1.3.6.1.4.1.4253.2.1.27.3.1.2CardShelfread-onlymandatory
oscCntrSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OSC cards.
1.3.6.1.4.1.4253.2.1.27.3.1.3CardSlotread-onlymandatory
oscCntrType
OBJECT-TYPE
The type of the software counter data in this row.
1.3.6.1.4.1.4253.2.1.27.3.1.4INTEGER {spi(1), ibm(2), hdlc(3)}read-onlymandatory
oscTotPktSent
OBJECT-TYPE
The number of data packets sent over the given data channel.
1.3.6.1.4.1.4253.2.1.27.3.1.5Counterread-onlymandatory
oscTotPktRcvd
OBJECT-TYPE
The number of data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.27.3.1.6Counterread-onlymandatory
oscTotBadTrans
OBJECT-TYPE
The number of bad data transmissions over the given data channel.
1.3.6.1.4.1.4253.2.1.27.3.1.7Counterread-onlymandatory
oscBadPktRcvd
OBJECT-TYPE
The number of bad data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.27.3.1.8Counterread-onlymandatory
oscBytesSent
OBJECT-TYPE
Total number of bytes sent over the given data channel.
1.3.6.1.4.1.4253.2.1.27.3.1.9Counterread-onlymandatory
oscBytesRcvd
OBJECT-TYPE
Total number of data bytes received over the given data channel.
1.3.6.1.4.1.4253.2.1.27.3.1.10Counterread-onlymandatory
oscMsgsDlvrd
OBJECT-TYPE
The number of complete messages delivered over the given data channel.
1.3.6.1.4.1.4253.2.1.27.3.1.11Counterread-onlymandatory
oscClearCntrs
OBJECT-TYPE
If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other
1.3.6.1.4.1.4253.2.1.27.3.1.12ResetTyperead-writemandatory
oscPmTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.1.27.4not-accessiblemandatory
oscPmEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.27.4.1not-accessiblemandatory
oscPmLocation
OBJECT-TYPE
The location of the OSC card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OSC cards.
1.3.6.1.4.1.4253.2.1.27.4.1.1CardLocationread-onlymandatory
oscPmShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OSC cards.
1.3.6.1.4.1.4253.2.1.27.4.1.2CardShelfread-onlymandatory
oscPmSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OSC cards.
1.3.6.1.4.1.4253.2.1.27.4.1.3CardSlotread-onlymandatory
oscPmErrors
OBJECT-TYPE
The number of packets errors since port last came online.
1.3.6.1.4.1.4253.2.1.27.4.1.4Counterread-onlymandatory
oscPmErredSecs
OBJECT-TYPE
The number of erred seconds since port last came online.
1.3.6.1.4.1.4253.2.1.27.4.1.5Counterread-onlymandatory
oscStartTime
OBJECT-TYPE
The date/time the port came last online.
1.3.6.1.4.1.4253.2.1.27.4.1.6DateAndTimeread-onlymandatory
oscClearPmCntrs
OBJECT-TYPE
If the value is reset, all PM counters for this port are reset to zero. A get on this will always return other
1.3.6.1.4.1.4253.2.1.27.4.1.7ResetTyperead-writemandatory
ocm4gPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.28
ocm4gNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all OCM4G modules in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.28.1Counterread-onlymandatory
ocm4gPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each OCM4G module.
1.3.6.1.4.1.4253.2.1.28.2not-accessiblemandatory
ocm4gPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.28.2.1not-accessiblemandatory
ocm4gPerfLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.1.28.2.1.1INTEGER {local(1)}read-onlymandatory
ocm4gPerfShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.1.28.2.1.2CardShelfread-onlymandatory
ocm4gPerfSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.1.28.2.1.3CardSlotread-onlymandatory
ocm4gPerfState
OBJECT-TYPE
The state of the OCM4G module. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.1.28.2.1.4CardStateread-onlymandatory
ocm4gPerfStatus
OBJECT-TYPE
The status of the OCM4G module. This status represents the status of the OCM4G module and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.28.2.1.5CardStatusread-onlymandatory
ocm4gLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.1.28.2.1.6DateAndTimeread-onlymandatory
ocm4gAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.28.2.1.7Counterread-onlymandatory
ocm4gErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.28.2.1.8Counterread-onlymandatory
ocm4gCntrTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.1.28.3not-accessiblemandatory
ocm4gCntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.28.3.1not-accessiblemandatory
ocm4gCntrLocation
OBJECT-TYPE
The location of the OCM4G card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM4G cards.
1.3.6.1.4.1.4253.2.1.28.3.1.1INTEGER {local(1)}read-onlymandatory
ocm4gCntrShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM4G cards.
1.3.6.1.4.1.4253.2.1.28.3.1.2CardShelfread-onlymandatory
ocm4gCntrSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM4G cards.
1.3.6.1.4.1.4253.2.1.28.3.1.3CardSlotread-onlymandatory
ocm4gCntrType
OBJECT-TYPE
The type of the software counter data in this row.
1.3.6.1.4.1.4253.2.1.28.3.1.4INTEGER {spi(1), ibm1(2), ibm2(3), hdlc(4)}read-onlymandatory
ocm4gTotPktSent
OBJECT-TYPE
The number of data packets sent over the given data channel.
1.3.6.1.4.1.4253.2.1.28.3.1.5Counterread-onlymandatory
ocm4gTotPktRcvd
OBJECT-TYPE
The number of data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.28.3.1.6Counterread-onlymandatory
ocm4gTotBadTrans
OBJECT-TYPE
The number of bad data transmissions over the given data channel.
1.3.6.1.4.1.4253.2.1.28.3.1.7Counterread-onlymandatory
ocm4gBadPktRcvd
OBJECT-TYPE
The number of bad data packets received over the given data channel.
1.3.6.1.4.1.4253.2.1.28.3.1.8Counterread-onlymandatory
ocm4gBytesSent
OBJECT-TYPE
Total number of bytes sent over the given data channel.
1.3.6.1.4.1.4253.2.1.28.3.1.9Counterread-onlymandatory
ocm4gBytesRcvd
OBJECT-TYPE
Total number of data bytes received over the given data channel.
1.3.6.1.4.1.4253.2.1.28.3.1.10Counterread-onlymandatory
ocm4gMsgsDlvrd
OBJECT-TYPE
The number of complete messages delivered over the given data channel.
1.3.6.1.4.1.4253.2.1.28.3.1.11Counterread-onlymandatory
ocm4gClearCntrs
OBJECT-TYPE
If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other
1.3.6.1.4.1.4253.2.1.28.3.1.12ResetTyperead-writemandatory
ocm4gPmTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.1.28.4not-accessiblemandatory
ocm4gPmEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.28.4.1not-accessiblemandatory
ocm4gPmLocation
OBJECT-TYPE
The location of the OCM4G card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OCM4G cards.
1.3.6.1.4.1.4253.2.1.28.4.1.1INTEGER {local(1)}read-onlymandatory
ocm4gPmShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OCM4G cards.
1.3.6.1.4.1.4253.2.1.28.4.1.2CardShelfread-onlymandatory
ocm4gPmSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OCM4G cards.
1.3.6.1.4.1.4253.2.1.28.4.1.3CardSlotread-onlymandatory
ocm4gPmLinkRxPwr
OBJECT-TYPE
Link receive power.
1.3.6.1.4.1.4253.2.1.28.4.1.5DisplayStringread-onlymandatory
ocm4gPmLinkTxPwr
OBJECT-TYPE
Link transmit power.
1.3.6.1.4.1.4253.2.1.28.4.1.6DisplayStringread-onlymandatory
ocm4gPmCpeRxPwr
OBJECT-TYPE
CPE receive power.
1.3.6.1.4.1.4253.2.1.28.4.1.7DisplayStringread-onlymandatory
ocm4gPmCpeTxPwr
OBJECT-TYPE
CPE transmit power.
1.3.6.1.4.1.4253.2.1.28.4.1.8DisplayStringread-onlymandatory
ocm4gPmNumLinkRxIntervals
OBJECT-TYPE
The of intervals (seconds) over which the link Rx statistics have been accumulated.
1.3.6.1.4.1.4253.2.1.28.4.1.9INTEGERread-onlymandatory
ocm4gPmLinkRxErrors
OBJECT-TYPE
Link receive errors.
1.3.6.1.4.1.4253.2.1.28.4.1.10DisplayStringread-onlymandatory
ocm4gPmLinkRxErredSeconds
OBJECT-TYPE
Link receive errored seconds.
1.3.6.1.4.1.4253.2.1.28.4.1.11Counterread-onlymandatory
ocm4gPmNumCpeRxIntervals
OBJECT-TYPE
The of intervals (seconds) over which the CPE Rx statistics have been accumulated.
1.3.6.1.4.1.4253.2.1.28.4.1.12INTEGERread-onlymandatory
ocm4gPmCpeRxErrors
OBJECT-TYPE
CPE receive errors.
1.3.6.1.4.1.4253.2.1.28.4.1.13DisplayStringread-onlymandatory
ocm4gPmCpeRxErredSeconds
OBJECT-TYPE
CPE receive errored seconds.
1.3.6.1.4.1.4253.2.1.28.4.1.14Counterread-onlymandatory
ocm4gPmNumCpeTxIntervals
OBJECT-TYPE
The of intervals (seconds) over which the CPE Tx statistics have been accumulated.
1.3.6.1.4.1.4253.2.1.28.4.1.15INTEGERread-onlymandatory
ocm4gPmCpeTxErrors
OBJECT-TYPE
CPE transmit errors.
1.3.6.1.4.1.4253.2.1.28.4.1.16DisplayStringread-onlymandatory
ocm4gPmCpeTxErredSeconds
OBJECT-TYPE
CPE transmit errored seconds.
1.3.6.1.4.1.4253.2.1.28.4.1.17Counterread-onlymandatory
ocm4gClearPmCntrs
OBJECT-TYPE
If the value is reset, all PM counters for this port are reset to zero. A get on this will always return other
1.3.6.1.4.1.4253.2.1.28.4.1.18ResetTyperead-writemandatory
oetPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.29
oetNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all OET modules in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.29.1Counterread-onlymandatory
oetPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each OET module.
1.3.6.1.4.1.4253.2.1.29.2not-accessiblemandatory
oetPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.29.2.1not-accessiblemandatory
oetPerfLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.1.29.2.1.1CardLocationread-onlymandatory
oetPerfShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.1.29.2.1.2CardShelfread-onlymandatory
oetPerfSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.1.29.2.1.3CardSlotread-onlymandatory
oetPerfState
OBJECT-TYPE
The state of the OET module. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.1.29.2.1.4CardStateread-onlymandatory
oetPerfStatus
OBJECT-TYPE
The status of the OET module. This status represents the status of the OET module and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.29.2.1.5CardStatusread-onlymandatory
oetLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.1.29.2.1.6DateAndTimeread-onlymandatory
oetAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.29.2.1.7Counterread-onlymandatory
oetErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.29.2.1.8Counterread-onlymandatory
oetPmLinkTable
OBJECT-TYPE
This table represents the information for each entry for the OET Link ports.
1.3.6.1.4.1.4253.2.1.29.3not-accessiblemandatory
oetPmLinkEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.29.3.1not-accessiblemandatory
oetPmLinkLocation
OBJECT-TYPE
The location of the OET card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OET cards.
1.3.6.1.4.1.4253.2.1.29.3.1.1CardLocationread-onlymandatory
oetPmLinkShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OET cards.
1.3.6.1.4.1.4253.2.1.29.3.1.2CardShelfread-onlymandatory
oetPmLinkSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OET cards.
1.3.6.1.4.1.4253.2.1.29.3.1.3CardSlotread-onlymandatory
oetPmLinkNumIntervals
OBJECT-TYPE
The of intervals (seconds) over which the link statistics have been accumulated.
1.3.6.1.4.1.4253.2.1.29.3.1.5INTEGERread-onlymandatory
oetPmLinkRxPwr
OBJECT-TYPE
Link receive power.
1.3.6.1.4.1.4253.2.1.29.3.1.6DisplayStringread-onlymandatory
oetPmLinkRxBytes
OBJECT-TYPE
Link Rx Bytes.
1.3.6.1.4.1.4253.2.1.29.3.1.7DisplayStringread-onlymandatory
oetPmLinkRxFcsErrs
OBJECT-TYPE
Link Rx FCS Errors.
1.3.6.1.4.1.4253.2.1.29.3.1.8DisplayStringread-onlymandatory
oetPmLinkTxPwr
OBJECT-TYPE
Link Tx power.
1.3.6.1.4.1.4253.2.1.29.3.1.9DisplayStringread-onlymandatory
oetPmLinkTxTemp
OBJECT-TYPE
Pump temp in C
1.3.6.1.4.1.4253.2.1.29.3.1.10DisplayStringread-onlymandatory
oetPmLinkTxBytes
OBJECT-TYPE
Link Tx Bytes.
1.3.6.1.4.1.4253.2.1.29.3.1.11DisplayStringread-onlymandatory
oetPmLinkFecTx
OBJECT-TYPE
FEC Link Tx.
1.3.6.1.4.1.4253.2.1.29.3.1.12DisplayStringread-onlymandatory
oetPmLinkFecCorrected1s
OBJECT-TYPE
FEC Corrected '1's
1.3.6.1.4.1.4253.2.1.29.3.1.13INTEGERread-onlymandatory
oetPmLinkFecCorrected0s
OBJECT-TYPE
FEC Corrected '0's
1.3.6.1.4.1.4253.2.1.29.3.1.14INTEGERread-onlymandatory
oetPmLinkFecCorrectedBit
OBJECT-TYPE
FEC Corrected Bits
1.3.6.1.4.1.4253.2.1.29.3.1.15INTEGERread-onlymandatory
oetPmLinkFecCorrectedByte
OBJECT-TYPE
FEC Corrected Bytes
1.3.6.1.4.1.4253.2.1.29.3.1.16INTEGERread-onlymandatory
oetPmLinkFecUncorrectedByte
OBJECT-TYPE
FEC Uncorrected Bytes
1.3.6.1.4.1.4253.2.1.29.3.1.17INTEGERread-onlymandatory
oetPmLinkFecBlock
OBJECT-TYPE
FEC Block Number
1.3.6.1.4.1.4253.2.1.29.3.1.18INTEGERread-onlymandatory
oetPmPortTable
OBJECT-TYPE
This table represents the information for each entry for the OET CPE ports.
1.3.6.1.4.1.4253.2.1.29.4not-accessiblemandatory
oetPmPortEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.29.4.1not-accessiblemandatory
oetPmPortLocation
OBJECT-TYPE
The location of the OET card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known OET cards.
1.3.6.1.4.1.4253.2.1.29.4.1.1CardLocationread-onlymandatory
oetPmPortShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) OET cards.
1.3.6.1.4.1.4253.2.1.29.4.1.2CardShelfread-onlymandatory
oetPmPortSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) OET cards.
1.3.6.1.4.1.4253.2.1.29.4.1.3CardSlotread-onlymandatory
oetPmPortIndex
OBJECT-TYPE
Port for which the statistics are for.
1.3.6.1.4.1.4253.2.1.29.4.1.4INTEGER {cpe(10)}read-onlymandatory
oetPmPortNumIntervals
OBJECT-TYPE
The of intervals (seconds) over which the port statistics have been accumulated.
1.3.6.1.4.1.4253.2.1.29.4.1.5INTEGERread-onlymandatory
oetPmPortRxPwr
OBJECT-TYPE
Port receive power.
1.3.6.1.4.1.4253.2.1.29.4.1.6DisplayStringread-onlymandatory
oetPmPortRxBytes
OBJECT-TYPE
Port Rx Bytes.
1.3.6.1.4.1.4253.2.1.29.4.1.7DisplayStringread-onlymandatory
oetPmPortRxFcsErrs
OBJECT-TYPE
Port Rx FCS Errors.
1.3.6.1.4.1.4253.2.1.29.4.1.8DisplayStringread-onlymandatory
oetPmPortTxPwr
OBJECT-TYPE
Link Tx power.
1.3.6.1.4.1.4253.2.1.29.4.1.9DisplayStringread-onlymandatory
oetPmPortTxTemp
OBJECT-TYPE
Pump temp in C
1.3.6.1.4.1.4253.2.1.29.4.1.10DisplayStringread-onlymandatory
oetPmPortTxBytes
OBJECT-TYPE
Port Tx Bytes.
1.3.6.1.4.1.4253.2.1.29.4.1.11DisplayStringread-onlymandatory
uobPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.30
uobNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all UOB modules in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.30.1Counterread-onlymandatory
uobPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each UOB module.
1.3.6.1.4.1.4253.2.1.30.2not-accessiblemandatory
uobPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.30.2.1not-accessiblemandatory
uobPerfLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.1.30.2.1.1CardLocationread-onlymandatory
uobPerfShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.1.30.2.1.2CardShelfread-onlymandatory
uobPerfSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.1.30.2.1.3CardSlotread-onlymandatory
uobPerfState
OBJECT-TYPE
The state of the UOB module. The states are: online = 2 and offline = 3
1.3.6.1.4.1.4253.2.1.30.2.1.4CardStateread-onlymandatory
uobPerfStatus
OBJECT-TYPE
This status represents the status of the UOB module and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.30.2.1.5CardStatusread-onlymandatory
uobLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.1.30.2.1.6DateAndTimeread-onlymandatory
uobAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.30.2.1.7Counterread-onlymandatory
uobErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.30.2.1.8Counterread-onlymandatory
uobPmTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.1.30.3not-accessiblemandatory
uobPmEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.30.3.1not-accessiblemandatory
uobPmLocation
OBJECT-TYPE
The location of the UOB card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known UOB cards.
1.3.6.1.4.1.4253.2.1.30.3.1.1CardLocationread-onlymandatory
uobPmShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) UOB cards.
1.3.6.1.4.1.4253.2.1.30.3.1.2CardShelfread-onlymandatory
uobPmSlot
OBJECT-TYPE
The slot within the shelf the card is in. Valid values are: 1 to 17. The system automatically determines the right value for this entry based on the known (available) UOB cards.
1.3.6.1.4.1.4253.2.1.30.3.1.3CardSlotread-onlymandatory
uobPmSystemStatus
OBJECT-TYPE
System Status
1.3.6.1.4.1.4253.2.1.30.3.1.4DisplayStringread-onlymandatory
uobPmPumpCurrent
OBJECT-TYPE
Pump Current in mA
1.3.6.1.4.1.4253.2.1.30.3.1.5DisplayStringread-onlymandatory
uobPmPumpTemp
OBJECT-TYPE
Pump temp in C
1.3.6.1.4.1.4253.2.1.30.3.1.6DisplayStringread-onlymandatory
uobPmInputPower
OBJECT-TYPE
Input pwr in dBm
1.3.6.1.4.1.4253.2.1.30.3.1.7DisplayStringread-onlymandatory
uobPmOutPower
OBJECT-TYPE
Output pwr in dBm
1.3.6.1.4.1.4253.2.1.30.3.1.8DisplayStringread-onlymandatory
uobPmTotalGain
OBJECT-TYPE
Total gain in dB
1.3.6.1.4.1.4253.2.1.30.3.1.9DisplayStringread-onlymandatory
uobPmReflection
OBJECT-TYPE
Reflection in dB
1.3.6.1.4.1.4253.2.1.30.3.1.10DisplayStringread-onlymandatory
fc8gPerf
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.1.31
fc8gNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all FC8G modules in this time slot (15 minutes).
1.3.6.1.4.1.4253.2.1.31.1Counterread-onlymandatory
fc8gPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each FC8G module.
1.3.6.1.4.1.4253.2.1.31.2not-accessiblemandatory
fc8gPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.1.31.2.1not-accessiblemandatory
fc8gPerfLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.1.31.2.1.1CardLocationread-onlymandatory
fc8gPerfShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.1.31.2.1.2CardShelfread-onlymandatory
fc8gPerfSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.1.31.2.1.3CardSlotread-onlymandatory
fc8gPerfState
OBJECT-TYPE
The state of the FC8G module. The states are: online, offline, empty or loopback.
1.3.6.1.4.1.4253.2.1.31.2.1.4CardStateread-onlymandatory
fc8gPerfStatus
OBJECT-TYPE
The status of the FC8G module. This status represents the status of the FC8G module and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.1.31.2.1.5CardStatusread-onlymandatory
fc8gLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.1.31.2.1.6DateAndTimeread-onlymandatory
fc8gAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.1.31.2.1.7Counterread-onlymandatory
fc8gErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.1.31.2.1.8Counterread-onlymandatory
historical
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2
systemHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.1
sysHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the overall system
1.3.6.1.4.1.4253.2.2.1.1not-accessiblemandatory
sysHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.1.1.1not-accessiblemandatory
sysHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.1.1.1.1HistoryModeread-onlymandatory
sysHLastBootTime
OBJECT-TYPE
The date and time of the last system boot. This time represents the boot time of a CP card. It is also anonymous with the power-up cycle of the chassis.
1.3.6.1.4.1.4253.2.2.1.1.1.2DateAndTimeread-onlymandatory
sysHAvailTime
OBJECT-TYPE
The number of seconds since the system has been up and running. The criteria for the system available time is having at least one CP running with atmost non-service affecting minor alarm system status
1.3.6.1.4.1.4253.2.2.1.1.1.3Counterread-onlymandatory
sysHErrFreeSecs
OBJECT-TYPE
The number of seconds that the device has not experienced any alarms. This counter is across all cards in the chassis. The system must be in Normal status for this counter to be incremented.
1.3.6.1.4.1.4253.2.2.1.1.1.4Counterread-onlymandatory
downloadHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.2
dlHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the download process
1.3.6.1.4.1.4253.2.2.2.1not-accessiblemandatory
dlHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.2.1.1not-accessiblemandatory
dlHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.2.1.1.1HistoryModeread-onlymandatory
dlHOkDownloads
OBJECT-TYPE
The number of successful downloads
1.3.6.1.4.1.4253.2.2.2.1.1.2Counterread-onlymandatory
dlHBadDownloads
OBJECT-TYPE
The number of failed downloads
1.3.6.1.4.1.4253.2.2.2.1.1.3Counterread-onlymandatory
dlHLongestTime
OBJECT-TYPE
Longest time for any download, in seconds
1.3.6.1.4.1.4253.2.2.2.1.1.4Gaugeread-onlymandatory
dlHLongestSize
OBJECT-TYPE
Longest download size for any download, in bytes
1.3.6.1.4.1.4253.2.2.2.1.1.5Gaugeread-onlymandatory
cpHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.3
cpHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the communication card
1.3.6.1.4.1.4253.2.2.3.1not-accessiblemandatory
cpHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.3.1.1not-accessiblemandatory
cpHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.3.1.1.1HistoryModeread-onlymandatory
cpHNumEvents
OBJECT-TYPE
Total number of events received by the active CP
1.3.6.1.4.1.4253.2.2.3.1.1.2Counterread-onlymandatory
cpHTrapsSent
OBJECT-TYPE
Total number of traps sent by the active CP
1.3.6.1.4.1.4253.2.2.3.1.1.3Counterread-onlymandatory
cpHSNMPCmdsRcvd
OBJECT-TYPE
Total number of SNMP commands received by the active CP.
1.3.6.1.4.1.4253.2.2.3.1.1.4Counterread-onlymandatory
cpHCntrTable
OBJECT-TYPE
This table represents the information for each entry for the software counters. It is only applicable to the active MPM card.
1.3.6.1.4.1.4253.2.2.3.2not-accessiblemandatory
cpHCntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.3.2.1not-accessiblemandatory
cpHCntrMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.3.2.1.1HistoryModeread-onlymandatory
cpHCntrShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10. The system automatically determines the right value for this entry based on the value of the current active CP card.
1.3.6.1.4.1.4253.2.2.3.2.1.2CardShelfread-onlymandatory
cpHCntrSlot
OBJECT-TYPE
The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the value of the current active CP card.
1.3.6.1.4.1.4253.2.2.3.2.1.3CardSlotread-onlymandatory
cpHCntrType
OBJECT-TYPE
The type of the software counter data in this row. The data is collected for the SPI data channels.
1.3.6.1.4.1.4253.2.2.3.2.1.4INTEGER {spi(1)}read-onlymandatory
cpHTotPktSent
OBJECT-TYPE
The number of data packets sent over the given data channel.
1.3.6.1.4.1.4253.2.2.3.2.1.5Counterread-onlymandatory
cpHTotPktRcvd
OBJECT-TYPE
The number of data packets received over the given data channel.
1.3.6.1.4.1.4253.2.2.3.2.1.6Counterread-onlymandatory
cpHBadPktRcvd
OBJECT-TYPE
The number of bad data packets received over the given data channel.
1.3.6.1.4.1.4253.2.2.3.2.1.7Counterread-onlymandatory
cpHTotBadTrans
OBJECT-TYPE
The number of bad data transmissions over the given data channel.
1.3.6.1.4.1.4253.2.2.3.2.1.8Counterread-onlymandatory
cpHBytesSent
OBJECT-TYPE
Total number of bytes sent over the given data channel.
1.3.6.1.4.1.4253.2.2.3.2.1.9Counterread-onlymandatory
cpHBytesRcvd
OBJECT-TYPE
Total number of data bytes received over the given data channel.
1.3.6.1.4.1.4253.2.2.3.2.1.10Counterread-onlymandatory
cpHMsgsDlvrd
OBJECT-TYPE
The number of complete messages delivered over the given data channel.
1.3.6.1.4.1.4253.2.2.3.2.1.11Counterread-onlymandatory
cpHBufAllocFail
OBJECT-TYPE
Number of buffer allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.2.3.2.1.12Counterread-onlymandatory
cpHEcbAllocFail
OBJECT-TYPE
Number of Event Control Block allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.2.3.2.1.13Counterread-onlymandatory
cpHHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each communication processor
1.3.6.1.4.1.4253.2.2.3.3not-accessiblemandatory
cpHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.3.3.1not-accessiblemandatory
cpHHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.3.3.1.1HistoryModeread-onlymandatory
cpHHistShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.2.3.3.1.2CardShelfread-onlymandatory
cpHHistSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.2.3.3.1.3CardSlotread-onlymandatory
cpHLastBootTime
OBJECT-TYPE
The date and time of the last boot for this CP.
1.3.6.1.4.1.4253.2.2.3.3.1.4DateAndTimeread-onlymandatory
cpHAvailTime
OBJECT-TYPE
The number of seconds that this CP has been up and running.
1.3.6.1.4.1.4253.2.2.3.3.1.5Counterread-onlymandatory
cpHErrFreeSecs
OBJECT-TYPE
The number of seconds that this CP has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.3.3.1.6Counterread-onlymandatory
ccHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.4
ccHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the channel card
1.3.6.1.4.1.4253.2.2.4.1not-accessiblemandatory
ccHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.4.1.1not-accessiblemandatory
ccHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.4.1.1.1HistoryModeread-onlymandatory
ccHNumEvents
OBJECT-TYPE
Total number of events received for all CC's
1.3.6.1.4.1.4253.2.2.4.1.1.2Counterread-onlymandatory
ccHCntrTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.2.4.2not-accessiblemandatory
ccHCntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.4.2.1not-accessiblemandatory
ccHCntrMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.4.2.1.1HistoryModeread-onlymandatory
ccHCntrLocation
OBJECT-TYPE
The location of the CC card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known CC cards.
1.3.6.1.4.1.4253.2.2.4.2.1.2CardLocationread-onlymandatory
ccHCntrShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10. The system automatically determines the right value for this entry based on the known (available) CC cards.
1.3.6.1.4.1.4253.2.2.4.2.1.3CardShelfread-onlymandatory
ccHCntrSlot
OBJECT-TYPE
The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) CC cards.
1.3.6.1.4.1.4253.2.2.4.2.1.4CardSlotread-onlymandatory
ccHCntrType
OBJECT-TYPE
The type of the software counter data in this row. The data is collected for the SPI data channels.
1.3.6.1.4.1.4253.2.2.4.2.1.5INTEGER {spi(1), iwm(2)}read-onlymandatory
ccHTotPktSent
OBJECT-TYPE
The number of data packets sent over the given data channel.
1.3.6.1.4.1.4253.2.2.4.2.1.6Counterread-onlymandatory
ccHTotPktRcvd
OBJECT-TYPE
The number of data packets received over the given data channel.
1.3.6.1.4.1.4253.2.2.4.2.1.7Counterread-onlymandatory
ccHBadPktRcvd
OBJECT-TYPE
The number of bad data packets received over the given data channel.
1.3.6.1.4.1.4253.2.2.4.2.1.8Counterread-onlymandatory
ccHTotBadTrans
OBJECT-TYPE
The number of bad data transmissions over the given data channel.
1.3.6.1.4.1.4253.2.2.4.2.1.9Counterread-onlymandatory
ccHBytesSent
OBJECT-TYPE
Total number of bytes sent over the given data channel.
1.3.6.1.4.1.4253.2.2.4.2.1.10Counterread-onlymandatory
ccHBytesRcvd
OBJECT-TYPE
Total number of data bytes received over the given data channel.
1.3.6.1.4.1.4253.2.2.4.2.1.11Counterread-onlymandatory
ccHMsgsDlvrd
OBJECT-TYPE
The number of complete messages delivered over the given data channel.
1.3.6.1.4.1.4253.2.2.4.2.1.12Counterread-onlymandatory
ccHBufAllocFail
OBJECT-TYPE
Number of buffer allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.2.4.2.1.13Counterread-onlymandatory
ccHEcbAllocFail
OBJECT-TYPE
Number of Event Control Block allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.2.4.2.1.14Counterread-onlymandatory
ccHHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each channel card
1.3.6.1.4.1.4253.2.2.4.3not-accessiblemandatory
ccHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.4.3.1not-accessiblemandatory
ccHHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.4.3.1.1HistoryModeread-onlymandatory
ccHHistLocation
OBJECT-TYPE
The location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) CC cards.
1.3.6.1.4.1.4253.2.2.4.3.1.2CardLocationread-onlymandatory
ccHHistShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.2.4.3.1.3CardShelfread-onlymandatory
ccHHistSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.2.4.3.1.4CardSlotread-onlymandatory
ccHLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.2.4.3.1.5DateAndTimeread-onlymandatory
ccHAvailTime
OBJECT-TYPE
The number of seconds that this CC has been up and running.
1.3.6.1.4.1.4253.2.2.4.3.1.6Counterread-onlymandatory
ccHErrFreeSecs
OBJECT-TYPE
The number of seconds that this CC has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.4.3.1.7Counterread-onlymandatory
muxHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.5
muxHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the mux/demux card
1.3.6.1.4.1.4253.2.2.5.1not-accessiblemandatory
muxHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.5.1.1not-accessiblemandatory
muxHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.5.1.1.1HistoryModeread-onlymandatory
muxHNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all MUX's.
1.3.6.1.4.1.4253.2.2.5.1.1.2Counterread-onlymandatory
muxHHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each mux/demux card
1.3.6.1.4.1.4253.2.2.5.2not-accessiblemandatory
muxHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.5.2.1not-accessiblemandatory
muxHHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.5.2.1.1HistoryModeread-onlymandatory
muxHHistLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.2.5.2.1.2CardLocationread-onlymandatory
muxHHistShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.2.5.2.1.3CardShelfread-onlymandatory
muxHHistSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.2.5.2.1.4CardSlotread-onlymandatory
muxHHistType
OBJECT-TYPE
The type of the mux. The choices are: mux or demux.
1.3.6.1.4.1.4253.2.2.5.2.1.5INTEGER {mux(4), demux(5), w4cd(10), w2cmd(13), w4cm(21)}read-onlymandatory
muxHLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.2.5.2.1.6DateAndTimeread-onlymandatory
muxHAvailTime
OBJECT-TYPE
The number of seconds that this Mux has been up and running.
1.3.6.1.4.1.4253.2.2.5.2.1.7Counterread-onlymandatory
muxHErrFreeSecs
OBJECT-TYPE
The number of seconds that this mux has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.5.2.1.8Counterread-onlymandatory
psHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.6
psHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the power supply card
1.3.6.1.4.1.4253.2.2.6.1not-accessiblemandatory
psHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.6.1.1not-accessiblemandatory
psHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.6.1.1.1HistoryModenot-accessiblemandatory
psHNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all Power Supplies.
1.3.6.1.4.1.4253.2.2.6.1.1.2Counternot-accessiblemandatory
fadmHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.7
fadmHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the fadm card
1.3.6.1.4.1.4253.2.2.7.1not-accessiblemandatory
fadmHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.7.1.1not-accessiblemandatory
fadmHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.7.1.1.1HistoryModeread-onlymandatory
fadmHNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all FADM's.
1.3.6.1.4.1.4253.2.2.7.1.1.2Counterread-onlymandatory
fadmHHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each fadm card
1.3.6.1.4.1.4253.2.2.7.2not-accessiblemandatory
fadmHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.7.2.1not-accessiblemandatory
fadmHHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.7.2.1.1HistoryModeread-onlymandatory
fadmHHistLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.2.7.2.1.2CardLocationread-onlymandatory
fadmHHistShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.2.7.2.1.3CardShelfread-onlymandatory
fadmHHistSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.2.7.2.1.4CardSlotread-onlymandatory
fadmHLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.2.7.2.1.6DateAndTimeread-onlymandatory
fadmHAvailTime
OBJECT-TYPE
The number of seconds that this Mux has been up and running.
1.3.6.1.4.1.4253.2.2.7.2.1.7Counterread-onlymandatory
fadmHErrFreeSecs
OBJECT-TYPE
The number of seconds that this mux has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.7.2.1.8Counterread-onlymandatory
oppmHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.8
oppmHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the oppm card
1.3.6.1.4.1.4253.2.2.8.1not-accessiblemandatory
oppmHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.8.1.1not-accessiblemandatory
oppmHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.8.1.1.1HistoryModenot-accessiblemandatory
oppmHNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all OPPM's.
1.3.6.1.4.1.4253.2.2.8.1.1.2Counternot-accessiblemandatory
oppmHHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each fadm card
1.3.6.1.4.1.4253.2.2.8.2not-accessiblemandatory
oppmHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.8.2.1not-accessiblemandatory
oppmHHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.8.2.1.1HistoryModenot-accessiblemandatory
oppmHHistLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.2.8.2.1.2CardLocationnot-accessiblemandatory
oppmHHistShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.2.8.2.1.3CardShelfnot-accessiblemandatory
oppmHHistSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.2.8.2.1.4CardSlotnot-accessiblemandatory
oppmHLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.2.8.2.1.6DateAndTimenot-accessiblemandatory
oppmHAvailTime
OBJECT-TYPE
The number of seconds that this Mux has been up and running.
1.3.6.1.4.1.4253.2.2.8.2.1.7Counternot-accessiblemandatory
oppmHErrFreeSecs
OBJECT-TYPE
The number of seconds that this mux has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.8.2.1.8Counternot-accessiblemandatory
mcmHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.9
mcmHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the channel card
1.3.6.1.4.1.4253.2.2.9.1not-accessiblemandatory
mcmHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.9.1.1not-accessiblemandatory
mcmHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.9.1.1.1HistoryModeread-onlymandatory
mcmHNumEvents
OBJECT-TYPE
Total number of events received for all mcmt1's/mcme1's
1.3.6.1.4.1.4253.2.2.9.1.1.2Counterread-onlymandatory
mcmHCntrTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.2.9.2not-accessiblemandatory
mcmHCntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.9.2.1not-accessiblemandatory
mcmHCntrMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.9.2.1.1HistoryModeread-onlymandatory
mcmHCntrLocation
OBJECT-TYPE
The location of the mcm/mcme1 card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmt1/mcme1 cards.
1.3.6.1.4.1.4253.2.2.9.2.1.2CardLocationread-onlymandatory
mcmHCntrShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.
1.3.6.1.4.1.4253.2.2.9.2.1.3CardShelfread-onlymandatory
mcmHCntrSlot
OBJECT-TYPE
The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.
1.3.6.1.4.1.4253.2.2.9.2.1.4CardSlotread-onlymandatory
mcmHCntrType
OBJECT-TYPE
The type of the software counter data in this row. The data is collected for the SPI data channels.
1.3.6.1.4.1.4253.2.2.9.2.1.5INTEGER {spi(1), iwm(2)}read-onlymandatory
mcmHTotPktSent
OBJECT-TYPE
The number of data packets sent over the given data channel.
1.3.6.1.4.1.4253.2.2.9.2.1.6Counterread-onlymandatory
mcmHTotPktRcvd
OBJECT-TYPE
The number of data packets received over the given data channel.
1.3.6.1.4.1.4253.2.2.9.2.1.7Counterread-onlymandatory
mcmHBadPktRcvd
OBJECT-TYPE
The number of bad data packets received over the given data channel.
1.3.6.1.4.1.4253.2.2.9.2.1.8Counterread-onlymandatory
mcmHTotBadTrans
OBJECT-TYPE
The number of bad data transmissions over the given data channel.
1.3.6.1.4.1.4253.2.2.9.2.1.9Counterread-onlymandatory
mcmHBytesSent
OBJECT-TYPE
Total number of bytes sent over the given data channel.
1.3.6.1.4.1.4253.2.2.9.2.1.10Counterread-onlymandatory
mcmHBytesRcvd
OBJECT-TYPE
Total number of data bytes received over the given data channel.
1.3.6.1.4.1.4253.2.2.9.2.1.11Counterread-onlymandatory
mcmHMsgsDlvrd
OBJECT-TYPE
The number of complete messages delivered over the given data channel.
1.3.6.1.4.1.4253.2.2.9.2.1.12Counterread-onlymandatory
mcmHBufAllocFail
OBJECT-TYPE
Number of buffer allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.2.9.2.1.13Counterread-onlymandatory
mcmHEcbAllocFail
OBJECT-TYPE
Number of Event Control Block allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.2.9.2.1.14Counterread-onlymandatory
mcmPortHIntervalTable
OBJECT-TYPE
This table represents the information for each entry for the mcmt1/mcme1 port counters.
1.3.6.1.4.1.4253.2.2.9.3not-accessiblemandatory
mcmPortHIntervalEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.9.3.1not-accessiblemandatory
mcmPortHIntervalLocation
OBJECT-TYPE
The location of the mcm/mcme1 card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcm/mcme1 cards.
1.3.6.1.4.1.4253.2.2.9.3.1.1CardLocationread-onlymandatory
mcmPortHIntervalShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.
1.3.6.1.4.1.4253.2.2.9.3.1.2CardShelfread-onlymandatory
mcmPortHIntervalSlot
OBJECT-TYPE
The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.
1.3.6.1.4.1.4253.2.2.9.3.1.3CardSlotread-onlymandatory
mcmPortHIntervalPort
OBJECT-TYPE
The port within the shelf the card is in. Valid values are: 1 to 4. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.
1.3.6.1.4.1.4253.2.2.9.3.1.4INTEGERread-onlymandatory
mcmPortHIntervalNumber
OBJECT-TYPE
The Interval number of the ds1 port. Valid values are: 1 to 96. The system automatically determines the right value for this entry based on the known (available) interval number.
1.3.6.1.4.1.4253.2.2.9.3.1.5INTEGERread-onlymandatory
mcmPortHIntervalASs
OBJECT-TYPE
MCMT1/MCME1 port's ASs counter for specific interval.
1.3.6.1.4.1.4253.2.2.9.3.1.6Counterread-onlymandatory
mcmPortHIntervalFrameASs
OBJECT-TYPE
MCMT1/MCME1 port's FrameASs counter for specific interval.
1.3.6.1.4.1.4253.2.2.9.3.1.7Counternot-accessiblemandatory
mcmPortHIntervalFEs
OBJECT-TYPE
MCMT1/MCME1 port's FEs counter for specific interval.
1.3.6.1.4.1.4253.2.2.9.3.1.8Counterread-onlymandatory
mcmPortHIntervalCRCErrs
OBJECT-TYPE
MCMT1/MCME1 port's CRC errs counter for specific interval.
1.3.6.1.4.1.4253.2.2.9.3.1.9Counterread-onlymandatory
mcmPortHIntervalSESs
OBJECT-TYPE
MCMT1/MCME1 port's SESs counter less than 15 mins.
1.3.6.1.4.1.4253.2.2.9.3.1.10Counterread-onlymandatory
mcmPortHIntervalSEFSs
OBJECT-TYPE
MCMT1/MCME1 port's SEFSs counter less than 15 mins.
1.3.6.1.4.1.4253.2.2.9.3.1.11Counterread-onlymandatory
mcmPortHIntervalUASs
OBJECT-TYPE
MCMT1/MCME1 port's UASs counter less than 15 mins.
1.3.6.1.4.1.4253.2.2.9.3.1.12Counterread-onlymandatory
mcmPortHIntervalLESs
OBJECT-TYPE
MCMT1/MCME1 port's LESs counter less than 15 mins.
1.3.6.1.4.1.4253.2.2.9.3.1.13Counterread-onlymandatory
mcmPortHIntervalBESs
OBJECT-TYPE
MCMT1/MCME1 port's BESs counter less than 15 mins.
1.3.6.1.4.1.4253.2.2.9.3.1.14Counterread-onlymandatory
mcmPortHIntervalDMs
OBJECT-TYPE
MCMT1/MCME1 port's DMSs counter less than 15 mins.
1.3.6.1.4.1.4253.2.2.9.3.1.15Counterread-onlymandatory
mcmPortHIntervalLCVs
OBJECT-TYPE
MCMT1/MCME1 port's LCVs counter less than 15 mins.
1.3.6.1.4.1.4253.2.2.9.3.1.16Counterread-onlymandatory
mcmPortHTotalTable
OBJECT-TYPE
This table represents the information for each entry for the mcmt1/mcme1 port counters.
1.3.6.1.4.1.4253.2.2.9.4not-accessiblemandatory
mcmPortHTotalEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.9.4.1not-accessiblemandatory
mcmPortHTotalLocation
OBJECT-TYPE
The location of the mcm card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcm/mcme1 cards.
1.3.6.1.4.1.4253.2.2.9.4.1.1CardLocationread-onlymandatory
mcmPortHTotalShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.
1.3.6.1.4.1.4253.2.2.9.4.1.2CardShelfread-onlymandatory
mcmPortHTotalSlot
OBJECT-TYPE
The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.
1.3.6.1.4.1.4253.2.2.9.4.1.3CardSlotread-onlymandatory
mcmPortHTotalPort
OBJECT-TYPE
The port within the shelf the card is in. Valid values are: 1 to 4. The system automatically determines the right value for this entry based on the known (available) mcmt1/mcme1 cards.
1.3.6.1.4.1.4253.2.2.9.4.1.4INTEGERread-onlymandatory
mcmPortHTotalASs
OBJECT-TYPE
MCMT1/MCME1 port's ASs counter for the last 24 hrs.
1.3.6.1.4.1.4253.2.2.9.4.1.5Counterread-onlymandatory
mcmPortHTotalFrameASs
OBJECT-TYPE
MCMT1/MCME1 port's FrameASs counter for the last 24 hrs.
1.3.6.1.4.1.4253.2.2.9.4.1.6Counternot-accessiblemandatory
mcmPortHTotalFEs
OBJECT-TYPE
MCMT1/MCME1 port's FEs counter for the last 24 hrs.
1.3.6.1.4.1.4253.2.2.9.4.1.7Counterread-onlymandatory
mcmPortHTotalCRCErrs
OBJECT-TYPE
MCMT1/MCME1 port's CRC errs counter for the last 24 hrs.
1.3.6.1.4.1.4253.2.2.9.4.1.8Counterread-onlymandatory
mcmPortHTotalSESs
OBJECT-TYPE
MCMT1/MCME1 port's SESs counter less than 15 mins.
1.3.6.1.4.1.4253.2.2.9.4.1.9Counterread-onlymandatory
mcmPortHTotalSEFSs
OBJECT-TYPE
MCMT1/MCME1 port's SEFSs counter less than 15 mins.
1.3.6.1.4.1.4253.2.2.9.4.1.10Counterread-onlymandatory
mcmPortHTotalUASs
OBJECT-TYPE
MCMT1/MCME1 port's UASs counter less than 15 mins.
1.3.6.1.4.1.4253.2.2.9.4.1.11Counterread-onlymandatory
mcmPortHTotalLESs
OBJECT-TYPE
MCMT1/MCME1 port's LESs counter less than 15 mins.
1.3.6.1.4.1.4253.2.2.9.4.1.12Counterread-onlymandatory
mcmPortHTotalBESs
OBJECT-TYPE
MCMT1/MCME1 port's BESs counter less than 15 mins.
1.3.6.1.4.1.4253.2.2.9.4.1.13Counterread-onlymandatory
mcmPortHTotalDMs
OBJECT-TYPE
MCMT1/MCME1 port's DMSs counter less than 15 mins.
1.3.6.1.4.1.4253.2.2.9.4.1.14Counterread-onlymandatory
mcmPortHTotalLCVs
OBJECT-TYPE
MCMT1/MCME1 port's LCVs counter less than 15 mins.
1.3.6.1.4.1.4253.2.2.9.4.1.15Counterread-onlymandatory
fnHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.10
fnHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the fan modules
1.3.6.1.4.1.4253.2.2.10.1not-accessiblemandatory
fnHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.10.1.1not-accessiblemandatory
fnHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.10.1.1.1HistoryModenot-accessiblemandatory
fnHNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all fan modules.
1.3.6.1.4.1.4253.2.2.10.1.1.2Counternot-accessiblemandatory
csimHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.11
csimHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the ColorSIM
1.3.6.1.4.1.4253.2.2.11.1not-accessiblemandatory
csimHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.11.1.1not-accessiblemandatory
csimHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm. The reason this has been made obsolete is that all colorsim related events would eventually be part of ocm events
1.3.6.1.4.1.4253.2.2.11.1.1.1HistoryModenot-accessiblemandatory
csimHNumEvents
OBJECT-TYPE
This variable keeps track of the number of events related to ColorSIM. The reason this has been made obsolete is that all colorsim related events would eventually be part of ocm events
1.3.6.1.4.1.4253.2.2.11.1.1.2Counternot-accessiblemandatory
csimHistIntervalTable
OBJECT-TYPE
This table represents the information for each colorsim card.
1.3.6.1.4.1.4253.2.2.11.2not-accessiblemandatory
csimHistIntervalEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.11.2.1not-accessiblemandatory
csimIntervalLocation
OBJECT-TYPE
Location of the ColorSIM module
1.3.6.1.4.1.4253.2.2.11.2.1.1CardLocationread-onlymandatory
csimIntervalShelf
OBJECT-TYPE
The shelf of the ColorSIM module
1.3.6.1.4.1.4253.2.2.11.2.1.2CardShelfread-onlymandatory
csimIntervalSlot
OBJECT-TYPE
The Slot of the ColorSIM module
1.3.6.1.4.1.4253.2.2.11.2.1.3CardSlotread-onlymandatory
csimIntervalNumber
OBJECT-TYPE
This variable indicates the interval for which the set of statistics data is available.
1.3.6.1.4.1.4253.2.2.11.2.1.4INTEGER (1..96)read-onlymandatory
csimIntervalEFIs
OBJECT-TYPE
The counter associated with the number of Error Free Interval Counts in this interval.
1.3.6.1.4.1.4253.2.2.11.2.1.5INTEGERread-onlymandatory
csimIntervalEIs
OBJECT-TYPE
The counter associated with the number of Errored Interval Counts in this interval.
1.3.6.1.4.1.4253.2.2.11.2.1.6INTEGERread-onlymandatory
csimIntervalSEIs
OBJECT-TYPE
The counter associated with the number of Severely Errored Interval Counts in this interval.
1.3.6.1.4.1.4253.2.2.11.2.1.7INTEGERread-onlymandatory
csimIntervalBERs
OBJECT-TYPE
The counter associated with the number of Bit Error Rate Counts in this interval. The unit is in the form of x.ye-z.
1.3.6.1.4.1.4253.2.2.11.2.1.8DisplayStringread-onlymandatory
csimIntervalUAIs
OBJECT-TYPE
The counter associated with the number of Unavailable Interval Counts in this interval.
1.3.6.1.4.1.4253.2.2.11.2.1.9INTEGERread-onlymandatory
csimIntervalValidData
OBJECT-TYPE
This variable indicates if the data for this interval is valid. Not supported
1.3.6.1.4.1.4253.2.2.11.2.1.10Booleannot-accessiblemandatory
csimIntervalDateTime
OBJECT-TYPE
Time in seconds elasped since 01/01/1970 00:00:00 GMT for this interval. Assuming local time is same as GMT
1.3.6.1.4.1.4253.2.2.11.2.1.11INTEGERread-onlymandatory
rpsmHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.12
rpsmHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the rpsm card
1.3.6.1.4.1.4253.2.2.12.1not-accessiblemandatory
rpsmHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.12.1.1not-accessiblemandatory
rpsmHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.12.1.1.1HistoryModenot-accessiblemandatory
rpsmHNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all RPSM's.
1.3.6.1.4.1.4253.2.2.12.1.1.2Counternot-accessiblemandatory
rpsmHHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each rpsm card
1.3.6.1.4.1.4253.2.2.12.2not-accessiblemandatory
rpsmHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.12.2.1not-accessiblemandatory
rpsmHHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.12.2.1.1HistoryModenot-accessiblemandatory
rpsmHHistLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.2.12.2.1.2CardLocationnot-accessiblemandatory
rpsmHHistShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.2.12.2.1.3CardShelfnot-accessiblemandatory
rpsmHHistSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.2.12.2.1.4CardSlotnot-accessiblemandatory
rpsmHLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.2.12.2.1.6DateAndTimenot-accessiblemandatory
rpsmHAvailTime
OBJECT-TYPE
The number of seconds that this rpsm has been up and running.
1.3.6.1.4.1.4253.2.2.12.2.1.7Counternot-accessiblemandatory
rpsmHErrFreeSecs
OBJECT-TYPE
The number of seconds that this rpsm has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.12.2.1.8Counternot-accessiblemandatory
rsdmHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.13
rsdmHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the rsdm card
1.3.6.1.4.1.4253.2.2.13.1not-accessiblemandatory
rsdmHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.13.1.1not-accessiblemandatory
rsdmHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.13.1.1.1HistoryModenot-accessiblemandatory
rsdmHNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all RSDM's.
1.3.6.1.4.1.4253.2.2.13.1.1.2Counternot-accessiblemandatory
rsdmHHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each rsdm card.
1.3.6.1.4.1.4253.2.2.13.2not-accessiblemandatory
rsdmHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.13.2.1not-accessiblemandatory
rsdmHHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.13.2.1.1HistoryModenot-accessiblemandatory
rsdmHHistLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.2.13.2.1.2CardLocationnot-accessiblemandatory
rsdmHHistShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.2.13.2.1.3CardShelfnot-accessiblemandatory
rsdmHHistSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.2.13.2.1.4CardSlotnot-accessiblemandatory
rsdmHLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.2.13.2.1.6DateAndTimenot-accessiblemandatory
rsdmHAvailTime
OBJECT-TYPE
The number of seconds that this rsdm has been up and running.
1.3.6.1.4.1.4253.2.2.13.2.1.7Counternot-accessiblemandatory
rsdmHErrFreeSecs
OBJECT-TYPE
The number of seconds that this rsdm has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.13.2.1.8Counternot-accessiblemandatory
rtdmHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.14
rtdmHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the rtdm card
1.3.6.1.4.1.4253.2.2.14.1not-accessiblemandatory
rtdmHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.14.1.1not-accessiblemandatory
rtdmHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.14.1.1.1HistoryModenot-accessiblemandatory
rtdmHNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all rtdm's.
1.3.6.1.4.1.4253.2.2.14.1.1.2Counternot-accessiblemandatory
rtdmHHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each rtdm card.
1.3.6.1.4.1.4253.2.2.14.2not-accessiblemandatory
rtdmHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.14.2.1not-accessiblemandatory
rtdmHHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.14.2.1.1HistoryModenot-accessiblemandatory
rtdmHHistLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.2.14.2.1.2CardLocationnot-accessiblemandatory
rtdmHHistShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.2.14.2.1.3CardShelfnot-accessiblemandatory
rtdmHHistSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.2.14.2.1.4CardSlotnot-accessiblemandatory
rtdmHLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.2.14.2.1.5DateAndTimenot-accessiblemandatory
rtdmHAvailTime
OBJECT-TYPE
The number of seconds that this rtdm has been up and running.
1.3.6.1.4.1.4253.2.2.14.2.1.6Counternot-accessiblemandatory
rtdmHErrFreeSecs
OBJECT-TYPE
The number of seconds that this rtdm has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.14.2.1.7Counternot-accessiblemandatory
osamHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.15
osamHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the osam module.
1.3.6.1.4.1.4253.2.2.15.1not-accessiblemandatory
osamHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.15.1.1not-accessiblemandatory
osamHMode
OBJECT-TYPE
The mode of data collection.
1.3.6.1.4.1.4253.2.2.15.1.1.1HistoryModeread-onlymandatory
osamHNumEvents
OBJECT-TYPE
Total number of events received for all osam's.
1.3.6.1.4.1.4253.2.2.15.1.1.2Counterread-onlymandatory
osamHHistTable
OBJECT-TYPE
This table represents the information for historical performance data collected for each osam module.
1.3.6.1.4.1.4253.2.2.15.2not-accessiblemandatory
osamHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.15.2.1not-accessiblemandatory
osamHHistMode
OBJECT-TYPE
The mode of the data collection.
1.3.6.1.4.1.4253.2.2.15.2.1.1HistoryModeread-onlymandatory
osamHHistLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.2.2.15.2.1.2CardLocationread-onlymandatory
osamHHistShelf
OBJECT-TYPE
The shelf number in which the module is plugged in.
1.3.6.1.4.1.4253.2.2.15.2.1.3CardShelfread-onlymandatory
osamHHistSlot
OBJECT-TYPE
The slot number in which the module is plugged in.
1.3.6.1.4.1.4253.2.2.15.2.1.4INTEGER (1..16)read-onlymandatory
osamHHistLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.2.15.2.1.5DateAndTimeread-onlymandatory
osamHHistAvailTime
OBJECT-TYPE
The number of seconds since the start of this historical mode that this module has been up and running.
1.3.6.1.4.1.4253.2.2.15.2.1.6Counterread-onlymandatory
osamHHistErrFreeSecs
OBJECT-TYPE
The number of seconds since the start of this historical mode that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.15.2.1.7Counterread-onlymandatory
rsmHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.16
rsmHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the rsm card
1.3.6.1.4.1.4253.2.2.16.1not-accessiblemandatory
rsmHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.16.1.1not-accessiblemandatory
rsmHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.16.1.1.1HistoryModeread-onlymandatory
rsmHNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all RSM's.
1.3.6.1.4.1.4253.2.2.16.1.1.2Counterread-onlymandatory
rsmHHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each rsm card.
1.3.6.1.4.1.4253.2.2.16.2not-accessiblemandatory
rsmHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.16.2.1not-accessiblemandatory
rsmHHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.16.2.1.1HistoryModeread-onlymandatory
rsmHHistLocation
OBJECT-TYPE
The location of the card.
1.3.6.1.4.1.4253.2.2.16.2.1.2CardLocationread-onlymandatory
rsmHHistShelf
OBJECT-TYPE
The shelf the card is in.
1.3.6.1.4.1.4253.2.2.16.2.1.3CardShelfread-onlymandatory
rsmHHistSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.2.16.2.1.4CardSlotread-onlymandatory
rsmHLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.2.16.2.1.6DateAndTimeread-onlymandatory
rsmHAvailTime
OBJECT-TYPE
The number of seconds that this rsm has been up and running.
1.3.6.1.4.1.4253.2.2.16.2.1.7Counterread-onlymandatory
rsmHErrFreeSecs
OBJECT-TYPE
The number of seconds that this rsm has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.16.2.1.8Counterread-onlymandatory
upsmHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.17
upsmHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the upsm card
1.3.6.1.4.1.4253.2.2.17.1not-accessiblemandatory
upsmHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.17.1.1not-accessiblemandatory
upsmHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.17.1.1.1HistoryModeread-onlymandatory
upsmHNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all UPSM's.
1.3.6.1.4.1.4253.2.2.17.1.1.2Counterread-onlymandatory
upsmHHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each upsm card.
1.3.6.1.4.1.4253.2.2.17.2not-accessiblemandatory
upsmHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.17.2.1not-accessiblemandatory
upsmHHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.17.2.1.1HistoryModeread-onlymandatory
upsmHHistLocation
OBJECT-TYPE
The location of the card.
1.3.6.1.4.1.4253.2.2.17.2.1.2CardLocationread-onlymandatory
upsmHHistShelf
OBJECT-TYPE
The shelf the card is in.
1.3.6.1.4.1.4253.2.2.17.2.1.3CardShelfread-onlymandatory
upsmHHistSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.2.17.2.1.4CardSlotread-onlymandatory
upsmHLastBootTime
OBJECT-TYPE
The date and time of the last boot for this card.
1.3.6.1.4.1.4253.2.2.17.2.1.6DateAndTimeread-onlymandatory
upsmHAvailTime
OBJECT-TYPE
The number of seconds that this upsm has been up and running.
1.3.6.1.4.1.4253.2.2.17.2.1.7Counterread-onlymandatory
upsmHErrFreeSecs
OBJECT-TYPE
The number of seconds that this upsm has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.17.2.1.8Counterread-onlymandatory
mcmescHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.18
mcmescHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the channel card
1.3.6.1.4.1.4253.2.2.18.1not-accessiblemandatory
mcmescHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.18.1.1not-accessiblemandatory
mcmescHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or long term.
1.3.6.1.4.1.4253.2.2.18.1.1.1HistoryModeread-onlymandatory
mcmescHNumEvents
OBJECT-TYPE
Total number of events received for all mcmesc's
1.3.6.1.4.1.4253.2.2.18.1.1.2Counterread-onlymandatory
mcmescHCntrTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.2.18.2not-accessiblemandatory
mcmescHCntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.18.2.1not-accessiblemandatory
mcmescHCntrMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or long term.
1.3.6.1.4.1.4253.2.2.18.2.1.1HistoryModeread-onlymandatory
mcmescHCntrLocation
OBJECT-TYPE
The location of the mcmesc card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmesc cards.
1.3.6.1.4.1.4253.2.2.18.2.1.2CardLocationread-onlymandatory
mcmescHCntrShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.
1.3.6.1.4.1.4253.2.2.18.2.1.3CardShelfread-onlymandatory
mcmescHCntrSlot
OBJECT-TYPE
The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.
1.3.6.1.4.1.4253.2.2.18.2.1.4CardSlotread-onlymandatory
mcmescHCntrType
OBJECT-TYPE
The type of the software counter data in this row. The data is collected for the SPI data channels.
1.3.6.1.4.1.4253.2.2.18.2.1.5INTEGER {spi(1), iwm(2)}read-onlymandatory
mcmescHTotPktSent
OBJECT-TYPE
The number of data packets sent over the given data channel.
1.3.6.1.4.1.4253.2.2.18.2.1.6Counterread-onlymandatory
mcmescHTotPktRcvd
OBJECT-TYPE
The number of data packets received over the given data channel.
1.3.6.1.4.1.4253.2.2.18.2.1.7Counterread-onlymandatory
mcmescHBadPktRcvd
OBJECT-TYPE
The number of bad data packets received over the given data channel.
1.3.6.1.4.1.4253.2.2.18.2.1.8Counterread-onlymandatory
mcmescHTotBadTrans
OBJECT-TYPE
The number of bad data transmissions over the given data channel.
1.3.6.1.4.1.4253.2.2.18.2.1.9Counterread-onlymandatory
mcmescHBytesSent
OBJECT-TYPE
Total number of bytes sent over the given data channel.
1.3.6.1.4.1.4253.2.2.18.2.1.10Counterread-onlymandatory
mcmescHBytesRcvd
OBJECT-TYPE
Total number of data bytes received over the given data channel.
1.3.6.1.4.1.4253.2.2.18.2.1.11Counterread-onlymandatory
mcmescHMsgsDlvrd
OBJECT-TYPE
The number of complete messages delivered over the given data channel.
1.3.6.1.4.1.4253.2.2.18.2.1.12Counterread-onlymandatory
mcmescPortHIntervalTable
OBJECT-TYPE
This table represents the information for each entry for the mcmesc port counters.
1.3.6.1.4.1.4253.2.2.18.3not-accessiblemandatory
mcmescPortHIntervalEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.18.3.1not-accessiblemandatory
mcmescPortHIntervalLocation
OBJECT-TYPE
The location of the mcmesc card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmesc cards.
1.3.6.1.4.1.4253.2.2.18.3.1.1CardLocationread-onlymandatory
mcmescPortHIntervalShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 3. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.
1.3.6.1.4.1.4253.2.2.18.3.1.2CardShelfread-onlymandatory
mcmescPortHIntervalSlot
OBJECT-TYPE
The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.
1.3.6.1.4.1.4253.2.2.18.3.1.3CardSlotread-onlymandatory
mcmescPortHIntervalPort
OBJECT-TYPE
The CPE port within the shelf the card is in. Valid values are: 1 to 12. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.
1.3.6.1.4.1.4253.2.2.18.3.1.4INTEGERread-onlymandatory
mcmescPortHIntervalNumber
OBJECT-TYPE
The interval number. Valid values are: 1 to 96, where 1 indicates the most recently completed interval.
1.3.6.1.4.1.4253.2.2.18.3.1.5INTEGERread-onlymandatory
mcmescPortHIntervalDuration
OBJECT-TYPE
MCMESC CPE port's duration, in seconds, for specific interval. The * indicates an incomplete interval resulted from interval setting change.
1.3.6.1.4.1.4253.2.2.18.3.1.6DisplayStringread-onlymandatory
mcmescPortHIntervalEns
OBJECT-TYPE
MCMESC CPE port's enabled seconds for specific interval.
1.3.6.1.4.1.4253.2.2.18.3.1.7DisplayStringread-onlymandatory
mcmescPortHIntervalLoss
OBJECT-TYPE
MCMESC CPE port's loss of signal seconds for specific interval.
1.3.6.1.4.1.4253.2.2.18.3.1.8DisplayStringread-onlymandatory
mcmescPortHIntervalCrcErr
OBJECT-TYPE
MCMESC CPE port's CRC errs counter for specific interval.
1.3.6.1.4.1.4253.2.2.18.3.1.9DisplayStringread-onlymandatory
mcmescPortHIntervalOobErr
OBJECT-TYPE
MCMESC CPE port's Out-of_band error counter for specific interval.
1.3.6.1.4.1.4253.2.2.18.3.1.10DisplayStringread-onlymandatory
mcmescPortHIntervalRdpErr
OBJECT-TYPE
MCMESC CPE port's Running Disparity error counter for specific interval.
1.3.6.1.4.1.4253.2.2.18.3.1.11DisplayStringread-onlymandatory
mcmescLinkHIntervalTable
OBJECT-TYPE
This table represents the information for each entry for the mcmesc port counters.
1.3.6.1.4.1.4253.2.2.18.4not-accessiblemandatory
mcmescLinkHIntervalEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.18.4.1not-accessiblemandatory
mcmescLinkHIntervalLocation
OBJECT-TYPE
The location of the mcmesc card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known mcmesc cards.
1.3.6.1.4.1.4253.2.2.18.4.1.1CardLocationread-onlymandatory
mcmescLinkHIntervalShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 2. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.
1.3.6.1.4.1.4253.2.2.18.4.1.2CardShelfread-onlymandatory
mcmescLinkHIntervalSlot
OBJECT-TYPE
The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) mcmesc cards.
1.3.6.1.4.1.4253.2.2.18.4.1.3CardSlotread-onlymandatory
mcmescLinkHIntervalNumber
OBJECT-TYPE
The interval number. Valid values are: 1 to 96, where 1 indicates the most recently completed interval.
1.3.6.1.4.1.4253.2.2.18.4.1.4INTEGERread-onlymandatory
mcmescLinkHIntervalDuration
OBJECT-TYPE
MCMESC link port's duration, in seconds, for specific interval. The * indicates an incomplete interval resulted from interval setting change.
1.3.6.1.4.1.4253.2.2.18.4.1.5DisplayStringread-onlymandatory
mcmescLinkHIntervalTsos
OBJECT-TYPE
MCMESC link port's test-sequence on seconds for specific interval.
1.3.6.1.4.1.4253.2.2.18.4.1.6DisplayStringread-onlymandatory
mcmescLinkHIntervalLoss
OBJECT-TYPE
MCMESC link port's loss of signal seconds for specific interval.
1.3.6.1.4.1.4253.2.2.18.4.1.7DisplayStringread-onlymandatory
mcmescLinkHIntervalCrcErr
OBJECT-TYPE
MCMESC link port's CRC errs counter for specific interval.
1.3.6.1.4.1.4253.2.2.18.4.1.8DisplayStringread-onlymandatory
mcmescLinkHIntervalOobErr
OBJECT-TYPE
MCMESC link port's Out-of_band error counter for specific interval.
1.3.6.1.4.1.4253.2.2.18.4.1.9DisplayStringread-onlymandatory
mcmescLinkHIntervalRdpErr
OBJECT-TYPE
MCMESC link port's Running Disparity error counter for specific interval.
1.3.6.1.4.1.4253.2.2.18.4.1.10DisplayStringread-onlymandatory
mcmescPortHTotalTable
OBJECT-TYPE
This table represents the information for each mcmesc cpe port's total counters of up to 96 intervals.
1.3.6.1.4.1.4253.2.2.18.5not-accessiblemandatory
mcmescPortHTotalEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.18.5.1not-accessiblemandatory
mcmescPortHTotalCardLocation
OBJECT-TYPE
Location of the MCMESC CPE port. Valid values are: Local in the same chassis, or remote to this chassis
1.3.6.1.4.1.4253.2.2.18.5.1.1CardLocationread-onlymandatory
mcmescPortHTotalCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1..2.
1.3.6.1.4.1.4253.2.2.18.5.1.2CardShelfread-onlymandatory
mcmescPortHTotalCardSlot
OBJECT-TYPE
The slot within the shelf the Module is in.
1.3.6.1.4.1.4253.2.2.18.5.1.3CardSlotread-onlymandatory
mcmescPortHTotalPort
OBJECT-TYPE
CPE port's index.
1.3.6.1.4.1.4253.2.2.18.5.1.4INTEGERread-onlymandatory
mcmescPortHTotalDuration
OBJECT-TYPE
MCMESC CPE port's total duration of up to 96 intervals.
1.3.6.1.4.1.4253.2.2.18.5.1.5Counterread-onlymandatory
mcmescPortHTotalEns
OBJECT-TYPE
MCMESC CPE port's total enabled seconds during up to 96 intervals.
1.3.6.1.4.1.4253.2.2.18.5.1.6Counterread-onlymandatory
mcmescPortHTotalLoss
OBJECT-TYPE
MCMESC CPE port's total loss of signal seconds during up to 96 intervals.
1.3.6.1.4.1.4253.2.2.18.5.1.7Counterread-onlymandatory
mcmescPortHTotalCrcErr
OBJECT-TYPE
MCMESC CPE port's total CRC error counter during up to 96 intervals.
1.3.6.1.4.1.4253.2.2.18.5.1.8DisplayStringread-onlymandatory
mcmescPortHTotalOobErr
OBJECT-TYPE
MCMESC CPE port's total Out-Of_Band error counter during up to 96 intervals.
1.3.6.1.4.1.4253.2.2.18.5.1.9DisplayStringread-onlymandatory
mcmescPortHTotalRdpErr
OBJECT-TYPE
MCMESC CPE port's total Running Disparity error counter during up to 96 intervals.
1.3.6.1.4.1.4253.2.2.18.5.1.10DisplayStringread-onlymandatory
mcmescLinkHTotalTable
OBJECT-TYPE
This table represents the information for each mcmesc cpe port's total counters of up to 96 intervals.
1.3.6.1.4.1.4253.2.2.18.6not-accessiblemandatory
mcmescLinkHTotalEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.18.6.1not-accessiblemandatory
mcmescLinkHTotalCardLocation
OBJECT-TYPE
Location of the MCMESC link port. Valid values are: Local in the same chassis, or remote to this chassis
1.3.6.1.4.1.4253.2.2.18.6.1.1CardLocationread-onlymandatory
mcmescLinkHTotalCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1..2.
1.3.6.1.4.1.4253.2.2.18.6.1.2CardShelfread-onlymandatory
mcmescLinkHTotalCardSlot
OBJECT-TYPE
The slot within the shelf the Module is in.
1.3.6.1.4.1.4253.2.2.18.6.1.3CardSlotread-onlymandatory
mcmescLinkHTotalDuration
OBJECT-TYPE
MCMESC link port's total duration of up to 96 intervals.
1.3.6.1.4.1.4253.2.2.18.6.1.4Counterread-onlymandatory
mcmescLinkHTotalTsos
OBJECT-TYPE
MCMESC link port's total test-sequence on seconds during up to 96 intervals.
1.3.6.1.4.1.4253.2.2.18.6.1.5Counterread-onlymandatory
mcmescLinkHTotalLoss
OBJECT-TYPE
MCMESC link port's total loss of signal seconds during up to 96 intervals.
1.3.6.1.4.1.4253.2.2.18.6.1.6Counterread-onlymandatory
mcmescLinkHTotalCrcErr
OBJECT-TYPE
MCMESC link port's total CRC error counter during up to 96 intervals.
1.3.6.1.4.1.4253.2.2.18.6.1.7DisplayStringread-onlymandatory
mcmescLinkHTotalOobErr
OBJECT-TYPE
MCMESC link port's total Out-Of_Band error counter during up to 96 intervals.
1.3.6.1.4.1.4253.2.2.18.6.1.8DisplayStringread-onlymandatory
mcmescLinkHTotalRdpErr
OBJECT-TYPE
MCMESC link port's total Running Disparity error counter during up to 96 intervals.
1.3.6.1.4.1.4253.2.2.18.6.1.9DisplayStringread-onlymandatory
tapHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.19
tapHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the TAP module.
1.3.6.1.4.1.4253.2.2.19.1not-accessiblemandatory
tapHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.19.1.1not-accessiblemandatory
tapHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.19.1.1.1HistoryModeread-onlymandatory
tapHNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all TAP modules.
1.3.6.1.4.1.4253.2.2.19.1.1.2Counterread-onlymandatory
tapHHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each TAP module
1.3.6.1.4.1.4253.2.2.19.2not-accessiblemandatory
tapHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.19.2.1not-accessiblemandatory
tapHHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.19.2.1.1HistoryModeread-onlymandatory
tapHHistLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.2.19.2.1.2CardLocationread-onlymandatory
tapHHistShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.2.19.2.1.3CardShelfread-onlymandatory
tapHHistSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.2.19.2.1.4CardSlotread-onlymandatory
tapHHistType
OBJECT-TYPE
Module type.
1.3.6.1.4.1.4253.2.2.19.2.1.5CardTyperead-onlymandatory
tapHLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.2.19.2.1.6DateAndTimeread-onlymandatory
tapHAvailTime
OBJECT-TYPE
The number of seconds that this module has been up and running.
1.3.6.1.4.1.4253.2.2.19.2.1.7Counterread-onlymandatory
tapHErrFreeSecs
OBJECT-TYPE
The number of seconds that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.19.2.1.8Counterread-onlymandatory
voadmHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.20
voadmHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the VOADM module.
1.3.6.1.4.1.4253.2.2.20.1not-accessiblemandatory
voadmHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.20.1.1not-accessiblemandatory
voadmHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.20.1.1.1HistoryModeread-onlymandatory
voadmHNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all VOADM modules.
1.3.6.1.4.1.4253.2.2.20.1.1.2Counterread-onlymandatory
voadmHHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each VOADM module
1.3.6.1.4.1.4253.2.2.20.2not-accessiblemandatory
voadmHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.20.2.1not-accessiblemandatory
voadmHHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.20.2.1.1HistoryModeread-onlymandatory
voadmHHistLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.2.20.2.1.2CardLocationread-onlymandatory
voadmHHistShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.2.20.2.1.3CardShelfread-onlymandatory
voadmHHistSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.2.20.2.1.4CardSlotread-onlymandatory
voadmHHistType
OBJECT-TYPE
Module type.
1.3.6.1.4.1.4253.2.2.20.2.1.5CardTyperead-onlymandatory
voadmHLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.2.20.2.1.6DateAndTimeread-onlymandatory
voadmHAvailTime
OBJECT-TYPE
The number of seconds that this module has been up and running.
1.3.6.1.4.1.4253.2.2.20.2.1.7Counterread-onlymandatory
voadmHErrFreeSecs
OBJECT-TYPE
The number of seconds that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.20.2.1.8Counterread-onlymandatory
dmmHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.21
dmmHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the DMM module.
1.3.6.1.4.1.4253.2.2.21.1not-accessiblemandatory
dmmHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.21.1.1not-accessiblemandatory
dmmHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.21.1.1.1HistoryModeread-onlymandatory
dmmHNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all DMM modules.
1.3.6.1.4.1.4253.2.2.21.1.1.2Counterread-onlymandatory
dmmHHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each DMM module
1.3.6.1.4.1.4253.2.2.21.2not-accessiblemandatory
dmmHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.21.2.1not-accessiblemandatory
dmmHHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.21.2.1.1HistoryModeread-onlymandatory
dmmHHistLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.2.21.2.1.2CardLocationread-onlymandatory
dmmHHistShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.2.21.2.1.3CardShelfread-onlymandatory
dmmHHistSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.2.21.2.1.4CardSlotread-onlymandatory
dmmHLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.2.21.2.1.5DateAndTimeread-onlymandatory
dmmHAvailTime
OBJECT-TYPE
The number of seconds that this module has been up and running.
1.3.6.1.4.1.4253.2.2.21.2.1.6Counterread-onlymandatory
dmmHErrFreeSecs
OBJECT-TYPE
The number of seconds that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.21.2.1.7Counterread-onlymandatory
ocm10gfHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.22
ocm10gfHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the OCM10GF module.
1.3.6.1.4.1.4253.2.2.22.1not-accessiblemandatory
ocm10gfHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.22.1.1not-accessiblemandatory
ocm10gfHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.22.1.1.1HistoryModeread-onlymandatory
ocm10gfHNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all OCM10GF modules.
1.3.6.1.4.1.4253.2.2.22.1.1.2Counterread-onlymandatory
ocm10gfHHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each OCM10GF module
1.3.6.1.4.1.4253.2.2.22.2not-accessiblemandatory
ocm10gfHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.22.2.1not-accessiblemandatory
ocm10gfHHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.22.2.1.1HistoryModeread-onlymandatory
ocm10gfHHistLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.2.22.2.1.2CardLocationread-onlymandatory
ocm10gfHHistShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.2.22.2.1.3CardShelfread-onlymandatory
ocm10gfHHistSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.2.22.2.1.4CardSlotread-onlymandatory
ocm10gfHLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.2.22.2.1.5DateAndTimeread-onlymandatory
ocm10gfHAvailTime
OBJECT-TYPE
The number of seconds that this module has been up and running.
1.3.6.1.4.1.4253.2.2.22.2.1.6Counterread-onlymandatory
ocm10gfHErrFreeSecs
OBJECT-TYPE
The number of seconds that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.22.2.1.7Counterread-onlymandatory
ocm2Hist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.23
ocm2HistTable
OBJECT-TYPE
This table represents the information for historical data collected for the OCM2 module.
1.3.6.1.4.1.4253.2.2.23.1not-accessiblemandatory
ocm2HistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.23.1.1not-accessiblemandatory
ocm2HMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.23.1.1.1HistoryModeread-onlymandatory
ocm2HNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all OCM2 modules.
1.3.6.1.4.1.4253.2.2.23.1.1.2Counterread-onlymandatory
ocm2HHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each OCM2 module
1.3.6.1.4.1.4253.2.2.23.2not-accessiblemandatory
ocm2HHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.23.2.1not-accessiblemandatory
ocm2HHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.23.2.1.1HistoryModeread-onlymandatory
ocm2HHistLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.2.23.2.1.2CardLocationread-onlymandatory
ocm2HHistShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.2.23.2.1.3CardShelfread-onlymandatory
ocm2HHistSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.2.23.2.1.4CardSlotread-onlymandatory
ocm2HLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.2.23.2.1.5DateAndTimeread-onlymandatory
ocm2HAvailTime
OBJECT-TYPE
The number of seconds that this module has been up and running.
1.3.6.1.4.1.4253.2.2.23.2.1.6Counterread-onlymandatory
ocm2HErrFreeSecs
OBJECT-TYPE
The number of seconds that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.23.2.1.7Counterread-onlymandatory
oscHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.24
oscHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the OSC module.
1.3.6.1.4.1.4253.2.2.24.1not-accessiblemandatory
oscHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.24.1.1not-accessiblemandatory
oscHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.24.1.1.1HistoryModeread-onlymandatory
oscHNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all OSC modules.
1.3.6.1.4.1.4253.2.2.24.1.1.2Counterread-onlymandatory
oscHHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each OSC module
1.3.6.1.4.1.4253.2.2.24.2not-accessiblemandatory
oscHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.24.2.1not-accessiblemandatory
oscHHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.24.2.1.1HistoryModeread-onlymandatory
oscHHistLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.2.24.2.1.2CardLocationread-onlymandatory
oscHHistShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.2.24.2.1.3CardShelfread-onlymandatory
oscHHistSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.2.24.2.1.4CardSlotread-onlymandatory
oscHLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.2.24.2.1.5DateAndTimeread-onlymandatory
oscHAvailTime
OBJECT-TYPE
The number of seconds that this module has been up and running.
1.3.6.1.4.1.4253.2.2.24.2.1.6Counterread-onlymandatory
oscHErrFreeSecs
OBJECT-TYPE
The number of seconds that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.24.2.1.7Counterread-onlymandatory
ocm4gHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.25
ocm4gHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the OCM4G module.
1.3.6.1.4.1.4253.2.2.25.1not-accessiblemandatory
ocm4gHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.25.1.1not-accessiblemandatory
ocm4gHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.25.1.1.1HistoryModeread-onlymandatory
ocm4gHNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all OCM4G modules.
1.3.6.1.4.1.4253.2.2.25.1.1.2Counterread-onlymandatory
ocm4gHHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each OCM4G module
1.3.6.1.4.1.4253.2.2.25.2not-accessiblemandatory
ocm4gHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.25.2.1not-accessiblemandatory
ocm4gHHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.25.2.1.1HistoryModeread-onlymandatory
ocm4gHHistLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.2.25.2.1.2INTEGER {local(1)}read-onlymandatory
ocm4gHHistShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.2.25.2.1.3CardShelfread-onlymandatory
ocm4gHHistSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.2.25.2.1.4CardSlotread-onlymandatory
ocm4gHLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.2.25.2.1.5DateAndTimeread-onlymandatory
ocm4gHAvailTime
OBJECT-TYPE
The number of seconds that this module has been up and running.
1.3.6.1.4.1.4253.2.2.25.2.1.6Counterread-onlymandatory
ocm4gHErrFreeSecs
OBJECT-TYPE
The number of seconds that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.25.2.1.7Counterread-onlymandatory
oetHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.26
uobHist
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.2.27
uobHistTable
OBJECT-TYPE
This table represents the information for historical data collected for the UOB module.
1.3.6.1.4.1.4253.2.2.27.1not-accessiblemandatory
uobHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.27.1.1not-accessiblemandatory
uobHMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.27.1.1.1HistoryModeread-onlymandatory
uobHNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all UOB modules.
1.3.6.1.4.1.4253.2.2.27.1.1.2Counterread-onlymandatory
uobHHistTable
OBJECT-TYPE
This table represents the information for performance data collected for each UOB module
1.3.6.1.4.1.4253.2.2.27.2not-accessiblemandatory
uobHHistEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.2.27.2.1not-accessiblemandatory
uobHHistMode
OBJECT-TYPE
The mode of the data collection. Valid values are: daily or longterm.
1.3.6.1.4.1.4253.2.2.27.2.1.1HistoryModeread-onlymandatory
uobHHistLocation
OBJECT-TYPE
The location of the module. Choices are local or remote.
1.3.6.1.4.1.4253.2.2.27.2.1.2CardLocationread-onlymandatory
uobHHistShelf
OBJECT-TYPE
The shelf the module is in.
1.3.6.1.4.1.4253.2.2.27.2.1.3CardShelfread-onlymandatory
uobHHistSlot
OBJECT-TYPE
The slot within the shelf the module is in.
1.3.6.1.4.1.4253.2.2.27.2.1.4CardSlotread-onlymandatory
uobHLastBootTime
OBJECT-TYPE
The date and time of the last boot for this module.
1.3.6.1.4.1.4253.2.2.27.2.1.5DateAndTimeread-onlymandatory
uobHAvailTime
OBJECT-TYPE
The number of seconds that this module has been up and running.
1.3.6.1.4.1.4253.2.2.27.2.1.6Counterread-onlymandatory
uobHErrFreeSecs
OBJECT-TYPE
The number of seconds that this module has not experienced any alarms.
1.3.6.1.4.1.4253.2.2.27.2.1.7Counterread-onlymandatory
specialConditions
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.3
systemCond
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.3.1
sysCStatus
OBJECT-TYPE
The global status of the system as computed based on the traps (events) that are generated. Choices are: Critical, Major, Minor or Normal.
1.3.6.1.4.1.4253.2.3.1.1CardStatusnot-accessiblemandatory
sysCSetMode
OBJECT-TYPE
If on, the special conditions counters will be activated. These counters continue counting until the mode is off. On startup, this flag is off.
1.3.6.1.4.1.4253.2.3.1.2FlagTypenot-accessiblemandatory
sysCAvailTime
OBJECT-TYPE
The number of seconds since this mode is started that the system has been up and running. The Criteria for the system available time is having at least one CP running with atmost non-service affecting minor alarm system status
1.3.6.1.4.1.4253.2.3.1.3Counternot-accessiblemandatory
sysCErrFreeSecs
OBJECT-TYPE
The number of seconds since this mode is started that the device has not experienced any alarms. This counter is across all cards in the chassis. The system must be in Normal status for this counter to be incremented.
1.3.6.1.4.1.4253.2.3.1.4Counternot-accessiblemandatory
downloadCond
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.3.2
dlCStatus
OBJECT-TYPE
The global status of the download task. The download task (download to the device) is either ftp-inprogress, module update inprogress or currently idle. Since only one download at the time is handled by the system, this flag is set to inprogress as soon as any download starts. It is reset back to idle when the download is completed. This flag is set to idle on system startup. This flag can be remotely set to idle if a previous FTP download was interrupted.
1.3.6.1.4.1.4253.2.3.2.1DownloadStatusnot-accessiblemandatory
dlCOkDownloads
OBJECT-TYPE
The number of successful downloads in this time interval (15 minutes).
1.3.6.1.4.1.4253.2.3.2.2Counternot-accessiblemandatory
dlCBadDownloads
OBJECT-TYPE
The number of failed downloads in this time interval (15 minutes).
1.3.6.1.4.1.4253.2.3.2.3Counternot-accessiblemandatory
dlCLongestTime
OBJECT-TYPE
Longest time for any download, in seconds, in this time interval (15 minutes).
1.3.6.1.4.1.4253.2.3.2.4Gaugenot-accessiblemandatory
dlCLongestSize
OBJECT-TYPE
Longest download size for any download, in bytes, in this time interval (15 minutes).
1.3.6.1.4.1.4253.2.3.2.5Gaugenot-accessiblemandatory
dlCCounterFlag
OBJECT-TYPE
Turns software counters On or Off.
1.3.6.1.4.1.4253.2.3.2.6FlagTypenot-accessiblemandatory
cpCond
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.3.3
cpCNumEvents
OBJECT-TYPE
Total number of events received by the active CP since this mode was activated.
1.3.6.1.4.1.4253.2.3.3.1Counternot-accessiblemandatory
cpCTrapsSent
OBJECT-TYPE
Total number of traps sent by the active CP since this mode was activated.
1.3.6.1.4.1.4253.2.3.3.2Counternot-accessiblemandatory
cpCSNMPCmdsRcvd
OBJECT-TYPE
Total number of SNMP commands received by the active CP since this mode was activated.
1.3.6.1.4.1.4253.2.3.3.3Counternot-accessiblemandatory
cpCCounterFlag
OBJECT-TYPE
Turns software counters On or Off.
1.3.6.1.4.1.4253.2.3.3.4FlagTypenot-accessiblemandatory
cpCCntrTable
OBJECT-TYPE
This table represents the information for each entry for the software counters. It is only applicable to the active MPM card.
1.3.6.1.4.1.4253.2.3.3.5not-accessiblemandatory
cpCCntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.3.5.1not-accessiblemandatory
cpCCntrShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10. The system automatically determines the right value for this entry based on the value of the current active CP card.
1.3.6.1.4.1.4253.2.3.3.5.1.1CardShelfnot-accessiblemandatory
cpCCntrSlot
OBJECT-TYPE
The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the value of the current active CP card.
1.3.6.1.4.1.4253.2.3.3.5.1.2CardSlotnot-accessiblemandatory
cpCCntrType
OBJECT-TYPE
The type of the software counter data in this row. The data is collected for the SPI data channels.
1.3.6.1.4.1.4253.2.3.3.5.1.3INTEGER {spi(1)}not-accessiblemandatory
cpCTotPktSent
OBJECT-TYPE
The number of data packets sent over the given data channel.
1.3.6.1.4.1.4253.2.3.3.5.1.4Counternot-accessiblemandatory
cpCTotPktRcvd
OBJECT-TYPE
The number of data packets received over the given data channel.
1.3.6.1.4.1.4253.2.3.3.5.1.5Counternot-accessiblemandatory
cpCBadPktRcvd
OBJECT-TYPE
The number of bad data packets received over the given data channel.
1.3.6.1.4.1.4253.2.3.3.5.1.6Counternot-accessiblemandatory
cpCTotBadTrans
OBJECT-TYPE
The number of bad data transmissions over the given data channel.
1.3.6.1.4.1.4253.2.3.3.5.1.7Counternot-accessiblemandatory
cpCBytesSent
OBJECT-TYPE
Total number of bytes sent over the given data channel.
1.3.6.1.4.1.4253.2.3.3.5.1.8Counternot-accessiblemandatory
cpCBytesRcvd
OBJECT-TYPE
Total number of data bytes received over the given data channel.
1.3.6.1.4.1.4253.2.3.3.5.1.9Counternot-accessiblemandatory
cpCMsgsDlvrd
OBJECT-TYPE
The number of complete messages delivered over the given data channel.
1.3.6.1.4.1.4253.2.3.3.5.1.10Counternot-accessiblemandatory
cpCBufAllocFail
OBJECT-TYPE
Number of buffer allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.3.3.5.1.11Counternot-accessiblemandatory
cpCEcbAllocFail
OBJECT-TYPE
Number of Event Control Block allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.3.3.5.1.12Counternot-accessiblemandatory
cpCPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each communication processor
1.3.6.1.4.1.4253.2.3.3.6not-accessiblemandatory
cpCPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.3.6.1not-accessiblemandatory
cpCPerfShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.3.3.6.1.1CardShelfnot-accessiblemandatory
cpCPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.3.3.6.1.2CardSlotnot-accessiblemandatory
cpCPerfMode
OBJECT-TYPE
The valid types are: active CP or standby CP
1.3.6.1.4.1.4253.2.3.3.6.1.3RedundancyModenot-accessiblemandatory
cpCPerfState
OBJECT-TYPE
The state of the communication card. The states are: online, offline, empty, loopback or diagnostics.
1.3.6.1.4.1.4253.2.3.3.6.1.4CardStatenot-accessiblemandatory
cpCPerfStatus
OBJECT-TYPE
The status of the communication processor. This status represents the state of the communication processor and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.3.3.6.1.5CardStatusnot-accessiblemandatory
cpCAvailTime
OBJECT-TYPE
The number of seconds since this mode is started that this CP has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.3.3.6.1.7Counternot-accessiblemandatory
cpCErrFreeSecs
OBJECT-TYPE
The number of seconds since this mode is started that this CP has not experienced any alarms.
1.3.6.1.4.1.4253.2.3.3.6.1.8Counternot-accessiblemandatory
ccCond
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.3.4
ccCNumEvents
OBJECT-TYPE
Total number of events received for all CC's since this mode was started.
1.3.6.1.4.1.4253.2.3.4.1Counternot-accessiblemandatory
ccCCntrTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.3.4.2not-accessiblemandatory
ccCCntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.4.2.1not-accessiblemandatory
ccCCntrLocation
OBJECT-TYPE
The location of the CC card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known CC cards.
1.3.6.1.4.1.4253.2.3.4.2.1.1CardLocationnot-accessiblemandatory
ccCCntrShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10. The system automatically determines the right value for this entry based on the known (available) CC cards.
1.3.6.1.4.1.4253.2.3.4.2.1.2CardShelfnot-accessiblemandatory
ccCCntrSlot
OBJECT-TYPE
The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) CC cards.
1.3.6.1.4.1.4253.2.3.4.2.1.3CardSlotnot-accessiblemandatory
ccCCntrType
OBJECT-TYPE
The type of the software counter data in this row. The data is collected for the SPI data channels.
1.3.6.1.4.1.4253.2.3.4.2.1.4INTEGER {spi(1), iwm(2)}not-accessiblemandatory
ccCCounterFlag
OBJECT-TYPE
Turns software counters, both On or both Off for this CC. When Off Clears both counters Statistic information
1.3.6.1.4.1.4253.2.3.4.2.1.5FlagTypenot-accessiblemandatory
ccCTotPktSent
OBJECT-TYPE
The number of data packets sent over the given data channel.
1.3.6.1.4.1.4253.2.3.4.2.1.6Counternot-accessiblemandatory
ccCTotPktRcvd
OBJECT-TYPE
The number of data packets received over the given data channel.
1.3.6.1.4.1.4253.2.3.4.2.1.7Counternot-accessiblemandatory
ccCBadPktRcvd
OBJECT-TYPE
The number of bad data packets received over the given data channel.
1.3.6.1.4.1.4253.2.3.4.2.1.8Counternot-accessiblemandatory
ccCTotBadTrans
OBJECT-TYPE
The number of bad data transmissions over the given data channel.
1.3.6.1.4.1.4253.2.3.4.2.1.9Counternot-accessiblemandatory
ccCBytesSent
OBJECT-TYPE
Total number of bytes sent over the given data channel.
1.3.6.1.4.1.4253.2.3.4.2.1.10Counternot-accessiblemandatory
ccCBytesRcvd
OBJECT-TYPE
Total number of data bytes received over the given data channel.
1.3.6.1.4.1.4253.2.3.4.2.1.11Counternot-accessiblemandatory
ccCMsgsDlvrd
OBJECT-TYPE
The number of complete messages delivered over the given data channel.
1.3.6.1.4.1.4253.2.3.4.2.1.12Counternot-accessiblemandatory
ccCBufAllocFail
OBJECT-TYPE
Number of buffer allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.3.4.2.1.13Counternot-accessiblemandatory
ccCEcbAllocFail
OBJECT-TYPE
Number of Event Control Block allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.3.4.2.1.14Counternot-accessiblemandatory
ccCClearCntrs
OBJECT-TYPE
If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other.
1.3.6.1.4.1.4253.2.3.4.2.1.15ResetTypenot-accessiblemandatory
ccCPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each channel card.
1.3.6.1.4.1.4253.2.3.4.3not-accessiblemandatory
ccCPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.4.3.1not-accessiblemandatory
ccCPerfLocation
OBJECT-TYPE
The location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) CC cards.
1.3.6.1.4.1.4253.2.3.4.3.1.1CardLocationnot-accessiblemandatory
ccCPerfShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.3.4.3.1.2CardShelfnot-accessiblemandatory
ccCPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.3.4.3.1.3CardSlotnot-accessiblemandatory
ccCPerfState
OBJECT-TYPE
The state of the channel card. The states' are: online, offline, empty, loopback or diagnostics.
1.3.6.1.4.1.4253.2.3.4.3.1.4CardStatenot-accessiblemandatory
ccCPerfStatus
OBJECT-TYPE
The status of the channel card. This status represents the status of the communication processor and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.3.4.3.1.5CardStatusnot-accessiblemandatory
ccCAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this CC has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.3.4.3.1.6Counternot-accessiblemandatory
ccCErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this CC has not experienced any alarms.
1.3.6.1.4.1.4253.2.3.4.3.1.7Counternot-accessiblemandatory
ccCBiasCurrent
OBJECT-TYPE
Bias current for the optical laser.
1.3.6.1.4.1.4253.2.3.4.3.1.8INTEGERnot-accessiblemandatory
ccCModulation
OBJECT-TYPE
The frequency modulation for the optical laser.
1.3.6.1.4.1.4253.2.3.4.3.1.9INTEGERnot-accessiblemandatory
ccCApc
OBJECT-TYPE
The APC value.
1.3.6.1.4.1.4253.2.3.4.3.1.10INTEGERnot-accessiblemandatory
ccCIwmModulation
OBJECT-TYPE
The frequency modulation for the IWM channel.
1.3.6.1.4.1.4253.2.3.4.3.1.11INTEGERnot-accessiblemandatory
ccCLaserOnOff
OBJECT-TYPE
The laser On/Off flag.
1.3.6.1.4.1.4253.2.3.4.3.1.12FlagTypenot-accessiblemandatory
ccCTemperature
OBJECT-TYPE
The current temperature, or the operating temperature of the optical device.
1.3.6.1.4.1.4253.2.3.4.3.1.13Gaugenot-accessiblemandatory
ccCIntensity
OBJECT-TYPE
The intensity of the optical light.
1.3.6.1.4.1.4253.2.3.4.3.1.14Gaugenot-accessiblemandatory
ccCSignalStrength
OBJECT-TYPE
The current signal strength for the optical path.
1.3.6.1.4.1.4253.2.3.4.3.1.15Gaugenot-accessiblemandatory
ccCLossOfLight
OBJECT-TYPE
If set to true, no laser light is present. If set to false, no loss of light has occurred.
1.3.6.1.4.1.4253.2.3.4.3.1.16Booleannot-accessiblemandatory
ccCSignalDetect
OBJECT-TYPE
If set to true, signal is detected. If set to false, no signal is present.
1.3.6.1.4.1.4253.2.3.4.3.1.17Booleannot-accessiblemandatory
ccCRefClock
OBJECT-TYPE
The value of the reference clock in decimal notation. For a given value, like 1660, the actual value is 16.60-EN. In otherwords, assume a two digit decimal point, plus any appropriate scaling factor.
1.3.6.1.4.1.4253.2.3.4.3.1.18INTEGER {en1660(1), en1944(2), en1953(3)}not-accessiblemandatory
ccCClockDiv
OBJECT-TYPE
The clock divisor. Values are 1250, 622 or 155 in the appropriate clock frequency scale.
1.3.6.1.4.1.4253.2.3.4.3.1.19INTEGER {dout-1250(1), dout-622(2), dout-155(3)}not-accessiblemandatory
ccCProtectionMode
OBJECT-TYPE
UPSR Protection Mode: active, standby and na.
1.3.6.1.4.1.4253.2.3.4.3.1.20INTEGER {active(1), standby(2), na(3)}not-accessiblemandatory
muxCond
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.3.5
muxCNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all MUX's since this mode is started.
1.3.6.1.4.1.4253.2.3.5.1Counternot-accessiblemandatory
muxCPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each mux/demux card
1.3.6.1.4.1.4253.2.3.5.2not-accessiblemandatory
muxCPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.5.2.1not-accessiblemandatory
muxCPerfLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.3.5.2.1.1CardLocationnot-accessiblemandatory
muxCPerfShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.3.5.2.1.2CardShelfnot-accessiblemandatory
muxCPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.3.5.2.1.3CardSlotnot-accessiblemandatory
muxCType
OBJECT-TYPE
The type of the mux. The choices are: mux or demux.
1.3.6.1.4.1.4253.2.3.5.2.1.4INTEGER {mux(4), demux(5), w4cd(10), w2cmd(13), w4cm(21)}not-accessiblemandatory
muxCPerfState
OBJECT-TYPE
The status of the mux card. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.3.5.2.1.5CardStatenot-accessiblemandatory
muxCPerfStatus
OBJECT-TYPE
The status of the mux card. This status represents the status of the mux card and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.3.5.2.1.6CardStatusnot-accessiblemandatory
muxCAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this Mux has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.3.5.2.1.7Counternot-accessiblemandatory
muxCErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this mux has not experienced any alarms.
1.3.6.1.4.1.4253.2.3.5.2.1.8Counternot-accessiblemandatory
muxCCounterFlag
OBJECT-TYPE
Turns special condition software counters On or Off for this card. Default is off.
1.3.6.1.4.1.4253.2.3.5.3FlagTypenot-accessiblemandatory
psCond
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.3.6
psCNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all Power Supplies since this mode is started.
1.3.6.1.4.1.4253.2.3.6.1Counternot-accessiblemandatory
psCVoltageLevel3pt3Volt
OBJECT-TYPE
Voltage Level of the 3.3 V power supply. Need to divide this value by ten to get the actual voltage level.
1.3.6.1.4.1.4253.2.3.6.2INTEGERnot-accessiblemandatory
psCVoltageLevel5Volt
OBJECT-TYPE
Voltage Level of the 5 V power supply. Need to divide this value by ten to get the actual voltage level.
1.3.6.1.4.1.4253.2.3.6.3INTEGERnot-accessiblemandatory
psCVoltageLevel12Volt
OBJECT-TYPE
Voltage Level of the 12 V power supply. Need to divide this value by ten to get the actual voltage level.
1.3.6.1.4.1.4253.2.3.6.4INTEGERnot-accessiblemandatory
psCPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each power supply card
1.3.6.1.4.1.4253.2.3.6.5not-accessiblemandatory
psCPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.6.5.1not-accessiblemandatory
psCPerfID
OBJECT-TYPE
The module id where ps is in. Valid values are: 1 to 4
1.3.6.1.4.1.4253.2.3.6.5.1.1INTEGERnot-accessiblemandatory
psCPerfType
OBJECT-TYPE
The type of the power supply card. The choices are: active (primary PS) or standby.
1.3.6.1.4.1.4253.2.3.6.5.1.2RedundancyModenot-accessiblemandatory
psCPerfState
OBJECT-TYPE
The state of the power supply card. The states are: online, offline, empty, loopback or diagnostics.
1.3.6.1.4.1.4253.2.3.6.5.1.3CardStatenot-accessiblemandatory
psCPerfStatus
OBJECT-TYPE
The status of the power supply card. This status represents the status of the ps card and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.3.6.5.1.4CardStatusnot-accessiblemandatory
fadmCond
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.3.7
fadmCNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all FADM's since this mode is started.
1.3.6.1.4.1.4253.2.3.7.1Counternot-accessiblemandatory
fadmCCounterFlag
OBJECT-TYPE
Turns software counters On or Off for this FADM.
1.3.6.1.4.1.4253.2.3.7.2FlagTypenot-accessiblemandatory
fadmCPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each fadm card
1.3.6.1.4.1.4253.2.3.7.3not-accessiblemandatory
fadmCPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.7.3.1not-accessiblemandatory
fadmCPerfLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.3.7.3.1.1CardLocationnot-accessiblemandatory
fadmCPerfShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.3.7.3.1.2CardShelfnot-accessiblemandatory
fadmCPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.3.7.3.1.3CardSlotnot-accessiblemandatory
fadmCPerfState
OBJECT-TYPE
The status of the mux card. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.3.7.3.1.5CardStatenot-accessiblemandatory
fadmCPerfStatus
OBJECT-TYPE
The status of the mux card. This status represents the status of the mux card and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.3.7.3.1.6CardStatusnot-accessiblemandatory
fadmCAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this Mux has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.3.7.3.1.7Counternot-accessiblemandatory
fadmCErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this mux has not experienced any alarms.
1.3.6.1.4.1.4253.2.3.7.3.1.8Counternot-accessiblemandatory
oppmCond
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.3.8
oppmCNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all OPPMs' since this mode is started.
1.3.6.1.4.1.4253.2.3.8.1Counternot-accessiblemandatory
oppmCPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each oppm card
1.3.6.1.4.1.4253.2.3.8.2not-accessiblemandatory
oppmCPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.8.2.1not-accessiblemandatory
oppmCPerfLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.3.8.2.1.1CardLocationnot-accessiblemandatory
oppmCPerfShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.3.8.2.1.2CardShelfnot-accessiblemandatory
oppmCPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.3.8.2.1.3CardSlotnot-accessiblemandatory
oppmCPerfState
OBJECT-TYPE
The status of the oppm card. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.3.8.2.1.4CardStatenot-accessiblemandatory
oppmCPerfStatus
OBJECT-TYPE
The status of the oppm card. This status represents the status of the oppm card and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.3.8.2.1.5CardStatusnot-accessiblemandatory
oppmCAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this oppm has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.3.8.2.1.6Counternot-accessiblemandatory
oppmCErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this oppm has not experienced any alarms.
1.3.6.1.4.1.4253.2.3.8.2.1.7Counternot-accessiblemandatory
oppmCCounterFlag
OBJECT-TYPE
Turns special condition software counters On or Off for this card. Default is off.
1.3.6.1.4.1.4253.2.3.8.3FlagTypenot-accessiblemandatory
mcmCond
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.3.9
mcmCNumEvents
OBJECT-TYPE
Total number of events received for all MCM's since this mode was started.
1.3.6.1.4.1.4253.2.3.9.1Counternot-accessiblemandatory
mcmCCntrTable
OBJECT-TYPE
This table represents the information for each entry for the software counters.
1.3.6.1.4.1.4253.2.3.9.2not-accessiblemandatory
mcmCCntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.9.2.1not-accessiblemandatory
mcmCCntrLocation
OBJECT-TYPE
The location of the MCM card. The values are: Local or Remote. The system automatically determines the right value for this entry based on the known MCM cards.
1.3.6.1.4.1.4253.2.3.9.2.1.1CardLocationnot-accessiblemandatory
mcmCCntrShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10. The system automatically determines the right value for this entry based on the known (available) MCM cards.
1.3.6.1.4.1.4253.2.3.9.2.1.2CardShelfnot-accessiblemandatory
mcmCCntrSlot
OBJECT-TYPE
The slot within the shelf the card is in. The system automatically determines the right value for this entry based on the known (available) MCM cards.
1.3.6.1.4.1.4253.2.3.9.2.1.3CardSlotnot-accessiblemandatory
mcmCCntrType
OBJECT-TYPE
The type of the software counter data in this row. The data is collected for the SPI data channels.
1.3.6.1.4.1.4253.2.3.9.2.1.4INTEGER {spi(1), iwm(2)}not-accessiblemandatory
mcmCCounterFlag
OBJECT-TYPE
Turns software counters On or Off for this MCM.
1.3.6.1.4.1.4253.2.3.9.2.1.5FlagTypenot-accessiblemandatory
mcmCTotPktSent
OBJECT-TYPE
The number of data packets sent over the given data channel.
1.3.6.1.4.1.4253.2.3.9.2.1.6Counternot-accessiblemandatory
mcmCTotPktRcvd
OBJECT-TYPE
The number of data packets received over the given data channel.
1.3.6.1.4.1.4253.2.3.9.2.1.7Counternot-accessiblemandatory
mcmCBadPktRcvd
OBJECT-TYPE
The number of bad data packets received over the given data channel.
1.3.6.1.4.1.4253.2.3.9.2.1.8Counternot-accessiblemandatory
mcmCTotBadTrans
OBJECT-TYPE
The number of bad data transmissions over the given data channel.
1.3.6.1.4.1.4253.2.3.9.2.1.9Counternot-accessiblemandatory
mcmCBytesSent
OBJECT-TYPE
Total number of bytes sent over the given data channel.
1.3.6.1.4.1.4253.2.3.9.2.1.10Counternot-accessiblemandatory
mcmCBytesRcvd
OBJECT-TYPE
Total number of data bytes received over the given data channel.
1.3.6.1.4.1.4253.2.3.9.2.1.11Counternot-accessiblemandatory
mcmCMsgsDlvrd
OBJECT-TYPE
The number of complete messages delivered over the given data channel.
1.3.6.1.4.1.4253.2.3.9.2.1.12Counternot-accessiblemandatory
mcmCBufAllocFail
OBJECT-TYPE
Number of buffer allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.3.9.2.1.13Counternot-accessiblemandatory
mcmCEcbAllocFail
OBJECT-TYPE
Number of Event Control Block allocation failures for the given data channel.
1.3.6.1.4.1.4253.2.3.9.2.1.14Counternot-accessiblemandatory
mcmCClearCntrs
OBJECT-TYPE
If the value is reset, all software counters for this 15 minute interval are reset to zero. A get on this will always return other.
1.3.6.1.4.1.4253.2.3.9.2.1.15ResetTypenot-accessiblemandatory
mcmCPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each channel card
1.3.6.1.4.1.4253.2.3.9.3not-accessiblemandatory
mcmCPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.9.3.1not-accessiblemandatory
mcmCPerfLocation
OBJECT-TYPE
The location of the card. Valid choices are Local or Remote. The system automatically selects this value based on the known (available) CC cards.
1.3.6.1.4.1.4253.2.3.9.3.1.1CardLocationnot-accessiblemandatory
mcmCPerfShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.3.9.3.1.2CardShelfnot-accessiblemandatory
mcmCPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.3.9.3.1.3CardSlotnot-accessiblemandatory
mcmCPerfState
OBJECT-TYPE
The state of the channel card. The states' are: online, offline, empty, loopback or diagnostics.
1.3.6.1.4.1.4253.2.3.9.3.1.4CardStatenot-accessiblemandatory
mcmCPerfStatus
OBJECT-TYPE
The status of the channel card. This status represents the status of the communication processor and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.3.9.3.1.5CardStatusnot-accessiblemandatory
mcmCAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this CC has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.3.9.3.1.6Counternot-accessiblemandatory
mcmCErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this MCM has not experienced any alarms.
1.3.6.1.4.1.4253.2.3.9.3.1.7Counternot-accessiblemandatory
mcmCBiasCurrent
OBJECT-TYPE
Bias current for the optical laser.
1.3.6.1.4.1.4253.2.3.9.3.1.8INTEGERnot-accessiblemandatory
mcmCModulation
OBJECT-TYPE
The frequency modulation for the optical laser.
1.3.6.1.4.1.4253.2.3.9.3.1.9INTEGERnot-accessiblemandatory
mcmCApc
OBJECT-TYPE
The APC value.
1.3.6.1.4.1.4253.2.3.9.3.1.10INTEGERnot-accessiblemandatory
mcmCIwmModulation
OBJECT-TYPE
The frequency modulation for the IWM channel.
1.3.6.1.4.1.4253.2.3.9.3.1.11INTEGERnot-accessiblemandatory
mcmCLaserOnOff
OBJECT-TYPE
The laser On/Off flag.
1.3.6.1.4.1.4253.2.3.9.3.1.12FlagTypenot-accessiblemandatory
mcmCTemperature
OBJECT-TYPE
The current temperature, or the operating temperature of the optical device.
1.3.6.1.4.1.4253.2.3.9.3.1.13Gaugenot-accessiblemandatory
mcmCIntensity
OBJECT-TYPE
The intensity of the optical light.
1.3.6.1.4.1.4253.2.3.9.3.1.14Gaugenot-accessiblemandatory
mcmCSignalStrength
OBJECT-TYPE
The current signal strength for the optical path.
1.3.6.1.4.1.4253.2.3.9.3.1.15Gaugenot-accessiblemandatory
mcmCLossOfLight
OBJECT-TYPE
If set to true, no laser light is present. If set to false, no loss of light has occurred.
1.3.6.1.4.1.4253.2.3.9.3.1.16Booleannot-accessiblemandatory
mcmCSignalDetect
OBJECT-TYPE
If set to true, signal is detected. If set to false, no signal is present.
1.3.6.1.4.1.4253.2.3.9.3.1.17Booleannot-accessiblemandatory
mcmCRefClock
OBJECT-TYPE
The value of the reference clock in decimal notation. For a given value, like 1660, the actual value is 16.60-EN. In otherwords, assume a two digit decimal point, plus any appropriate scaling factor.
1.3.6.1.4.1.4253.2.3.9.3.1.18INTEGER {en1660(1), en1944(2), en1953(3)}not-accessiblemandatory
mcmCClockDiv
OBJECT-TYPE
The clock divisor. Values are 1250, 622 or 155 in the appropriate clock frequency scale.
1.3.6.1.4.1.4253.2.3.9.3.1.19INTEGER {dout-1250(1), dout-622(2), dout-155(3)}not-accessiblemandatory
mcmPortCCntrTable
OBJECT-TYPE
This table represents the information for each MCM port's current counters.
1.3.6.1.4.1.4253.2.3.9.4not-accessiblemandatory
mcmPortCCntrEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.9.4.1not-accessiblemandatory
mcmPortCCntrCardLocation
OBJECT-TYPE
Location of the MCM port. Valid values are: Local in the same chassis, or remote to this chassis
1.3.6.1.4.1.4253.2.3.9.4.1.1CardLocationnot-accessiblemandatory
mcmPortCCntrCardShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 2..3.
1.3.6.1.4.1.4253.2.3.9.4.1.2CardShelfnot-accessiblemandatory
mcmPortCCntrCardSlot
OBJECT-TYPE
The slot within the shelf the Module is in.
1.3.6.1.4.1.4253.2.3.9.4.1.3CardSlotnot-accessiblemandatory
mcmPortCCntrIndex
OBJECT-TYPE
Port's index.
1.3.6.1.4.1.4253.2.3.9.4.1.4INTEGERnot-accessiblemandatory
mcmPortCCntrASs
OBJECT-TYPE
mcm port's ASs counter less than 15 mins.
1.3.6.1.4.1.4253.2.3.9.4.1.5Counternot-accessiblemandatory
mcmPortCCntrFEs
OBJECT-TYPE
MCM port's FEs counter less than 15 mins.
1.3.6.1.4.1.4253.2.3.9.4.1.7Counternot-accessiblemandatory
mcmPortCCntrCRCErrs
OBJECT-TYPE
MCM port's CRC errs counter less than 15 mins.
1.3.6.1.4.1.4253.2.3.9.4.1.8Counternot-accessiblemandatory
mcmPortCCntrSESs
OBJECT-TYPE
mcm port's SESs counter less than 15 mins.
1.3.6.1.4.1.4253.2.3.9.4.1.9Counternot-accessiblemandatory
mcmPortCCntrSEFSs
OBJECT-TYPE
MCM port's SEFSs counter less than 15 mins.
1.3.6.1.4.1.4253.2.3.9.4.1.10Counternot-accessiblemandatory
mcmPortCCntrUASs
OBJECT-TYPE
MCM port's UASs counter less than 15 mins.
1.3.6.1.4.1.4253.2.3.9.4.1.11Counternot-accessiblemandatory
mcmPortCCntrLESs
OBJECT-TYPE
MCM port's LESs counter less than 15 mins.
1.3.6.1.4.1.4253.2.3.9.4.1.12Counternot-accessiblemandatory
mcmPortCCntrBESs
OBJECT-TYPE
MCM port's BESs counter less than 15 mins.
1.3.6.1.4.1.4253.2.3.9.4.1.13Counternot-accessiblemandatory
mcmPortCCntrDMs
OBJECT-TYPE
MCM port's DMSs counter less than 15 mins.
1.3.6.1.4.1.4253.2.3.9.4.1.14Counternot-accessiblemandatory
mcmPortCCntrLCVs
OBJECT-TYPE
MCM port's LCVs counter less than 15 mins.
1.3.6.1.4.1.4253.2.3.9.4.1.15Counternot-accessiblemandatory
fnCond
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.3.10
fnCNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all Fans since this mode is started.
1.3.6.1.4.1.4253.2.3.10.1Counternot-accessiblemandatory
fnCPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each fan module.
1.3.6.1.4.1.4253.2.3.10.2not-accessiblemandatory
fnCPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.10.2.1not-accessiblemandatory
fnCPerfID
OBJECT-TYPE
The module ID where the fan module is plugged in.
1.3.6.1.4.1.4253.2.3.10.2.1.1INTEGERnot-accessiblemandatory
fnCPerfState
OBJECT-TYPE
The state of the fan module.
1.3.6.1.4.1.4253.2.3.10.2.1.2INTEGER {fnOK(1), fnDegrade(2), fnFailed(3), fnEmpty(4)}not-accessiblemandatory
fnCPerfStatus
OBJECT-TYPE
The status of the fan module. This status represents the status of the fan module and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.3.10.2.1.3CardStatusnot-accessiblemandatory
rpsmCond
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.3.12
rpsmCNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all RPSMs' since this mode is started.
1.3.6.1.4.1.4253.2.3.12.1Counternot-accessiblemandatory
rpsmCPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each rpsm card
1.3.6.1.4.1.4253.2.3.12.2not-accessiblemandatory
rpsmCPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.12.2.1not-accessiblemandatory
rpsmCPerfLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.3.12.2.1.1CardLocationnot-accessiblemandatory
rpsmCPerfShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.3.12.2.1.2CardShelfnot-accessiblemandatory
rpsmCPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.3.12.2.1.3CardSlotnot-accessiblemandatory
rpsmCPerfState
OBJECT-TYPE
The state of the rpsm card. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.3.12.2.1.4CardStatenot-accessiblemandatory
rpsmCPerfStatus
OBJECT-TYPE
The status of the rpsm card. This status represents the status of the rpsm card and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.3.12.2.1.5CardStatusnot-accessiblemandatory
rpsmCAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this rpsm has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.3.12.2.1.6Counternot-accessiblemandatory
rpsmCErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this rpsm has not experienced any alarms.
1.3.6.1.4.1.4253.2.3.12.2.1.7Counternot-accessiblemandatory
rpsmCCounterFlag
OBJECT-TYPE
Turns special condition software counters On or Off for this card. Default is off.
1.3.6.1.4.1.4253.2.3.12.3FlagTypenot-accessiblemandatory
rsdmCond
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.3.13
rsdmCNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all RSDMs' since this mode is started.
1.3.6.1.4.1.4253.2.3.13.1Counternot-accessiblemandatory
rsdmCPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each oppm card
1.3.6.1.4.1.4253.2.3.13.2not-accessiblemandatory
rsdmCPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.13.2.1not-accessiblemandatory
rsdmCPerfLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.3.13.2.1.1CardLocationnot-accessiblemandatory
rsdmCPerfShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.3.13.2.1.2CardShelfnot-accessiblemandatory
rsdmCPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.3.13.2.1.3CardSlotnot-accessiblemandatory
rsdmCPerfState
OBJECT-TYPE
The state of the rsdm card. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.3.13.2.1.4CardStatenot-accessiblemandatory
rsdmCPerfStatus
OBJECT-TYPE
The status of the rsdm card. This status represents the status of the rsdm card and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.3.13.2.1.5CardStatusnot-accessiblemandatory
rsdmCAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this rsdm has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.3.13.2.1.6Counternot-accessiblemandatory
rsdmCErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this rsdm has not experienced any alarms.
1.3.6.1.4.1.4253.2.3.13.2.1.7Counternot-accessiblemandatory
rsdmCCounterFlag
OBJECT-TYPE
Turns special condition software counters On or Off for this card. Default is off.
1.3.6.1.4.1.4253.2.3.13.3FlagTypenot-accessiblemandatory
rtdmCond
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.3.14
rtdmCNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all RTDM's since this mode is started.
1.3.6.1.4.1.4253.2.3.14.1Counternot-accessiblemandatory
rtdmCPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each mux/demux card
1.3.6.1.4.1.4253.2.3.14.2not-accessiblemandatory
rtdmCPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.14.2.1not-accessiblemandatory
rtdmCPerfLocation
OBJECT-TYPE
The location of the card. Choices are local or remote.
1.3.6.1.4.1.4253.2.3.14.2.1.1CardLocationnot-accessiblemandatory
rtdmCPerfShelf
OBJECT-TYPE
The shelf the card is in. Valid values are: 1 to 10
1.3.6.1.4.1.4253.2.3.14.2.1.2CardShelfnot-accessiblemandatory
rtdmCPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.3.14.2.1.3CardSlotnot-accessiblemandatory
rtdmCPerfState
OBJECT-TYPE
The status of the mux card. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.3.14.2.1.4CardStatenot-accessiblemandatory
rtdmCPerfStatus
OBJECT-TYPE
The status of the mux card. This status represents the status of the mux card and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.3.14.2.1.5CardStatusnot-accessiblemandatory
rtdmCAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this Mux has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.3.14.2.1.6Counternot-accessiblemandatory
rtdmCErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this mux has not experienced any alarms.
1.3.6.1.4.1.4253.2.3.14.2.1.7Counternot-accessiblemandatory
rtdmCCounterFlag
OBJECT-TYPE
Turns special condition software counters On or Off for this card. Default is off.
1.3.6.1.4.1.4253.2.3.14.3FlagTypenot-accessiblemandatory
osamCond
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.3.15
osamCNumEvents
OBJECT-TYPE
Total number of events received for all osam's since this mode was started.
1.3.6.1.4.1.4253.2.3.15.1Counternot-accessiblemandatory
osamCPerfTable
OBJECT-TYPE
This table represents the information for special conditions performance data collected for each osam module.
1.3.6.1.4.1.4253.2.3.15.2not-accessiblemandatory
osamCPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.15.2.1not-accessiblemandatory
osamCPerfLocation
OBJECT-TYPE
Location of the module.
1.3.6.1.4.1.4253.2.3.15.2.1.1CardLocationnot-accessiblemandatory
osamCPerfShelf
OBJECT-TYPE
The shelf number in which the module is plugged in.
1.3.6.1.4.1.4253.2.3.15.2.1.2CardShelfnot-accessiblemandatory
osamCPerfSlot
OBJECT-TYPE
The slot number in which the module is plugged in.
1.3.6.1.4.1.4253.2.3.15.2.1.3INTEGER (1..16)not-accessiblemandatory
osamCPerfState
OBJECT-TYPE
The current state of the module.
1.3.6.1.4.1.4253.2.3.15.2.1.4CardStatenot-accessiblemandatory
osamCPerfStatus
OBJECT-TYPE
The current alarm status of the channel.
1.3.6.1.4.1.4253.2.3.15.2.1.5CardStatusnot-accessiblemandatory
osamCPerfAvailTime
OBJECT-TYPE
The number of seconds since the start of this mode that this module has been up and running.
1.3.6.1.4.1.4253.2.3.15.2.1.6Counternot-accessiblemandatory
osamCPerfErrFreeSecs
OBJECT-TYPE
The number of seconds since the start of this mode that this module has been experienced any alarms.
1.3.6.1.4.1.4253.2.3.15.2.1.7Counternot-accessiblemandatory
osamCPerfCounterFlag
OBJECT-TYPE
Turns osam special condition software counters on and off. Default is off.
1.3.6.1.4.1.4253.2.3.15.3FlagTypenot-accessiblemandatory
rsmCond
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.3.16
rsmCNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all RSMs' since this mode is started.
1.3.6.1.4.1.4253.2.3.16.1Counternot-accessiblemandatory
rsmCPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each rsm card
1.3.6.1.4.1.4253.2.3.16.2not-accessiblemandatory
rsmCPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.16.2.1not-accessiblemandatory
rsmCPerfLocation
OBJECT-TYPE
The location of the card.
1.3.6.1.4.1.4253.2.3.16.2.1.1CardLocationnot-accessiblemandatory
rsmCPerfShelf
OBJECT-TYPE
The shelf the card is in.
1.3.6.1.4.1.4253.2.3.16.2.1.2CardShelfnot-accessiblemandatory
rsmCPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.3.16.2.1.3CardSlotnot-accessiblemandatory
rsmCPerfState
OBJECT-TYPE
The state of the rsm card. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.3.16.2.1.4CardStatenot-accessiblemandatory
rsmCPerfStatus
OBJECT-TYPE
The status of the rsm card. This status represents the status of the rsm card and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.3.16.2.1.5CardStatusnot-accessiblemandatory
rsmCAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this rsm has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.3.16.2.1.6Counternot-accessiblemandatory
rsmCErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this rsm has not experienced any alarms.
1.3.6.1.4.1.4253.2.3.16.2.1.7Counternot-accessiblemandatory
rsmCCounterFlag
OBJECT-TYPE
Turns special condition software counters On or Off for this card. Default is off.
1.3.6.1.4.1.4253.2.3.16.3FlagTypenot-accessiblemandatory
upsmCond
OBJECT-IDENTITY
1.3.6.1.4.1.4253.2.3.17
upsmCNumEvents
OBJECT-TYPE
Total number of all traps (events) generated by all UPSMs' since this mode is started.
1.3.6.1.4.1.4253.2.3.17.1Counternot-accessiblemandatory
upsmCPerfTable
OBJECT-TYPE
This table represents the information for performance data collected for each upsm card
1.3.6.1.4.1.4253.2.3.17.2not-accessiblemandatory
upsmCPerfEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.2.3.17.2.1not-accessiblemandatory
upsmCPerfLocation
OBJECT-TYPE
The location of the card.
1.3.6.1.4.1.4253.2.3.17.2.1.1CardLocationnot-accessiblemandatory
upsmCPerfShelf
OBJECT-TYPE
The shelf the card is in.
1.3.6.1.4.1.4253.2.3.17.2.1.2CardShelfnot-accessiblemandatory
upsmCPerfSlot
OBJECT-TYPE
The slot within the shelf the card is in.
1.3.6.1.4.1.4253.2.3.17.2.1.3CardSlotnot-accessiblemandatory
upsmCPerfState
OBJECT-TYPE
The state of the upsm card. The states are: online, offline, empty, loopback or diag.
1.3.6.1.4.1.4253.2.3.17.2.1.4CardStatenot-accessiblemandatory
upsmCPerfStatus
OBJECT-TYPE
The status of the upsm card. This status represents the status of the upsm card and in general is different from the status of the system.
1.3.6.1.4.1.4253.2.3.17.2.1.5CardStatusnot-accessiblemandatory
upsmCAvailTime
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this upsm has been up and running. This will generally be the same as 15 minutes in seconds (900).
1.3.6.1.4.1.4253.2.3.17.2.1.6Counternot-accessiblemandatory
upsmCErrFreeSecs
OBJECT-TYPE
The number of seconds in this time slot (15 minutes) that this upsm has not experienced any alarms.
1.3.6.1.4.1.4253.2.3.17.2.1.7Counternot-accessiblemandatory
upsmCCounterFlag
OBJECT-TYPE
Turns special condition software counters On or Off for this card. Default is off.
1.3.6.1.4.1.4253.2.3.17.3FlagTypenot-accessiblemandatory
faults
OBJECT-IDENTITY
1.3.6.1.4.1.4253.3
eventLog
OBJECT-IDENTITY
1.3.6.1.4.1.4253.3.1
eveTrapThreshold
OBJECT-TYPE
Threshold before events of the same type are no longer sent. Default can be a number as small as 1.
1.3.6.1.4.1.4253.3.1.1INTEGERnot-accessiblemandatory
eveNumEvents
OBJECT-TYPE
Number of events logged in the table below. This counter is automatically set by the software.
1.3.6.1.4.1.4253.3.1.2EventBufferread-onlymandatory
eveLogTable
OBJECT-TYPE
This table represents the information for the event log buffer. There are a maximum of 700 entries in the event log. The events are kept in a circular buffer fashion with eveSeqNum going from 1 to 9999.
1.3.6.1.4.1.4253.3.1.3not-accessiblemandatory
eveLogEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.3.1.3.1not-accessiblemandatory
eveDateTime
OBJECT-TYPE
The date and time of the event logged in the buffer
1.3.6.1.4.1.4253.3.1.3.1.1DateAndTimeread-onlymandatory
eveEventId
OBJECT-TYPE
The event ID assigned to this event.
1.3.6.1.4.1.4253.3.1.3.1.2INTEGER (0..9999)read-onlymandatory
eveSeverity
OBJECT-TYPE
The severity of this event. Could be critical, major, minor, or normal (informational).
1.3.6.1.4.1.4253.3.1.3.1.3TrapStatusread-onlymandatory
eveSysStatus
OBJECT-TYPE
The current status of the system. Could be critical, major, minor, or normal (informational).
1.3.6.1.4.1.4253.3.1.3.1.4CardStatusread-onlymandatory
eveSource
OBJECT-TYPE
A five to seven tuple string composed of the following items: System Name:card type (MPM, OCMITU, OFCM, etc.). location (L for local, R[number] for remote with optional station number). shelf #. slot id[. port #][:link name(optional depending on card type)] [:ring name(optional)] [:path name(optional)]. When an event applies to all slots of the whole chassis, 0 will be displayed for both shelf and slot. Example: SystemInSunnyvale:OCMITU.L.1.6:ITU23
1.3.6.1.4.1.4253.3.1.3.1.5DisplayString (SIZE(0..152))read-onlymandatory
eveDescr
OBJECT-TYPE
A string signifying the cause of the error in natural language (preferrably English) format.
1.3.6.1.4.1.4253.3.1.3.1.6DisplayString (SIZE(0..100))read-onlymandatory
eveTrap
OBJECT-TYPE
If set to True, this event was sent as a trap. If set to False, this event was merely logged and not sent as a trap.
1.3.6.1.4.1.4253.3.1.3.1.7Booleanread-onlymandatory
eveSeqNum
OBJECT-TYPE
The unique sequence number for this event entry in the event log.
1.3.6.1.4.1.4253.3.1.3.1.8INTEGER (0..9999)read-onlymandatory
eveDeleteLog
OBJECT-TYPE
If the value is reset, the event log table of the active cp is deleted - meaning all the log entries are flushed!!
1.3.6.1.4.1.4253.3.1.4ResetTyperead-writemandatory
eveLastEntryDateTime
OBJECT-TYPE
Date and time stamp of the last event log entry. This provides quick access into the last event log entry.
1.3.6.1.4.1.4253.3.1.5DateAndTimeread-onlymandatory
eveHundredthEntryDateTime
OBJECT-TYPE
Date and time stamp of the most recent 100th event log entry. This provides quick access into retrieving the most recent 100 event log entries. If less than 100 entries exist in the event log, the return value contains all zeroes.
1.3.6.1.4.1.4253.3.1.6DateAndTimeread-onlymandatory
eveTwoHundredthEntryDateTime
OBJECT-TYPE
Date and time stamp of the most recent 200th event log entry. This provides quick access into retrieving the most recent 200 event log entries. If less than 200 entries exist in the event log, the return value contains all zeroes.
1.3.6.1.4.1.4253.3.1.7DateAndTimeread-onlymandatory
eveThreeHundredthEntryDateTime
OBJECT-TYPE
Date and time stamp of the most recent 300th event log entry. This provides quick access into retrieving the most recent 300 event log entries. If less than 300 entries exist in the event log, the return value contains all zeroes.
1.3.6.1.4.1.4253.3.1.8DateAndTimeread-onlymandatory
eveFourHundredthEntryDateTime
OBJECT-TYPE
Date and time stamp of the most recent 400th event log entry. This provides quick access into retrieving the most recent 400 event log entries. If less than 400 entries exist in the event log, the return value contains all zeroes.
1.3.6.1.4.1.4253.3.1.9DateAndTimeread-onlymandatory
eveFiveHundredthEntryDateTime
OBJECT-TYPE
Date and time stamp of the most recent 500th event log entry. This provides quick access into retrieving the most recent 500 event log entries. If less than 500 entries exist in the event log, the return value contains all zeroes.
1.3.6.1.4.1.4253.3.1.10DateAndTimeread-onlymandatory
eveSixHundredthEntryDateTime
OBJECT-TYPE
Date and time stamp of the most recent 600th event log entry. This provides quick access into retrieving the most recent 600 event log entries. If less than 600 entries exist in the event log, the return value contains all zeroes.
1.3.6.1.4.1.4253.3.1.11DateAndTimeread-onlymandatory
eveSevenHundredthEntryDateTime
OBJECT-TYPE
Date and time stamp of the most recent 700th event log entry. This provides quick access into retrieving the most recent 700 event log entries. If less than 700 entries exist in the event log, the return value contains all zeroes.
1.3.6.1.4.1.4253.3.1.12DateAndTimeread-onlymandatory
eveEightHundredthEntryDateTime
OBJECT-TYPE
Date and time stamp of the most recent 800th event log entry. This provides quick access into retrieving the most recent 800 event log entries. If less than 800 entries exist in the event log, the return value contains all zeroes.
1.3.6.1.4.1.4253.3.1.13DateAndTimenot-accessiblemandatory
eveNineHundredthEntryDateTime
OBJECT-TYPE
Date and time stamp of the most recent 900th event log entry. This provides quick access into retrieving the most recent 900 event log entries. If less than 900 entries exist in the event log, the return value contains all zeroes.
1.3.6.1.4.1.4253.3.1.14DateAndTimenot-accessiblemandatory
userLog
OBJECT-IDENTITY
1.3.6.1.4.1.4253.3.2
usrNumLogs
OBJECT-TYPE
Number of user events logged in the table below. This counter is automatically set by the software.
1.3.6.1.4.1.4253.3.2.1UserBuffernot-accessiblemandatory
usrLogTable
OBJECT-TYPE
This table represents the information for user event log buffer
1.3.6.1.4.1.4253.3.2.2not-accessiblemandatory
usrLogEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.3.2.2.1not-accessiblemandatory
usrDateTime
OBJECT-TYPE
The date and time of the event logged in the buffer
1.3.6.1.4.1.4253.3.2.2.1.1DateAndTimenot-accessiblemandatory
usrLogonId
OBJECT-TYPE
The Logon ID of the user causing this event to be logged.
1.3.6.1.4.1.4253.3.2.2.1.2LogonIDnot-accessiblemandatory
usrTarget
OBJECT-TYPE
A four tuple string composed of the following items: location (remote or local), type (cp, cc, mux or ps), shelf, and slot id. The tuples are separated by comma. Example: local,cp,b,1. This column identifies which subsystem was affected by the user action.
1.3.6.1.4.1.4253.3.2.2.1.3DisplayString (SIZE(0..30))not-accessiblemandatory
usrLogDescr
OBJECT-TYPE
A string signifying the action logged in natural language (preferrably English) format.
1.3.6.1.4.1.4253.3.2.2.1.4DisplayString (SIZE(0..100))not-accessiblemandatory
usrTrap
OBJECT-TYPE
If set to True, this user event was sent as a trap. If set to False, this event was merely logged and not sent as a trap.
1.3.6.1.4.1.4253.3.2.2.1.5Booleannot-accessiblemandatory
diagnostics
OBJECT-IDENTITY
1.3.6.1.4.1.4253.3.3
diagModeNum
OBJECT-TYPE
Number of cards in diagnostics mode in the table below. This counter is automatically set by the software.
1.3.6.1.4.1.4253.3.3.1INTEGER (0..128)read-onlymandatory
diagModeTable
OBJECT-TYPE
This table represents the information for each card in diagnostics mode.
1.3.6.1.4.1.4253.3.3.2not-accessiblemandatory
diagModeEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.3.3.2.1not-accessiblemandatory
diagLocation
OBJECT-TYPE
The location of the card: local or remote
1.3.6.1.4.1.4253.3.3.2.1.1CardLocationread-onlymandatory
diagShelf
OBJECT-TYPE
The shelf in which the card is located.
1.3.6.1.4.1.4253.3.3.2.1.2CardShelfread-onlymandatory
diagSlot
OBJECT-TYPE
The card slot in which the card is located.
1.3.6.1.4.1.4253.3.3.2.1.3CardSlotread-onlymandatory
diagSetMode
OBJECT-TYPE
If on, the card will be in diagnostics mode. If off, the card comes out of diagnostics mode.
1.3.6.1.4.1.4253.3.3.2.1.4INTEGER {other(1), warmboot(2), loopbackDisabled(3), loopbackEnabled(4), selftest(5)}read-onlymandatory
diagTestNum
OBJECT-TYPE
Number of built-in diagnostics tests in the table below.
1.3.6.1.4.1.4253.3.3.3INTEGER (0..20)read-onlymandatory
diagTestTable
OBJECT-TYPE
This table represents the information for each built-in diagnostics test.
1.3.6.1.4.1.4253.3.3.4not-accessiblemandatory
diagTestEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.3.3.4.1not-accessiblemandatory
diagTestId
OBJECT-TYPE
The name of the built-in diagnostics test.
1.3.6.1.4.1.4253.3.3.4.1.1INTEGER {lLoopBack(1), rLoopBack(2), lNormal(3), rNormal(4)}read-writemandatory
diagTLocation
OBJECT-TYPE
The location of the card to run the test on
1.3.6.1.4.1.4253.3.3.4.1.2CardLocationread-writemandatory
diagTShelf
OBJECT-TYPE
The shelf in which the card is located.
1.3.6.1.4.1.4253.3.3.4.1.3CardShelfread-writemandatory
diagTSlot
OBJECT-TYPE
The card slot in which the card is located.
1.3.6.1.4.1.4253.3.3.4.1.4CardSlotread-writemandatory
diagParam1
OBJECT-TYPE
The first parameter, if any to pass to the built-in test module. This parameter may be NULL to signify no run-time parameters. If there is a parameter in, any data type, it should be passed as a String equivalent.
1.3.6.1.4.1.4253.3.3.4.1.5DisplayString (SIZE(0..30))read-writemandatory
diagParam2
OBJECT-TYPE
The second parameter, if any to pass to the built-in test module. This parameter may be NULL to signify no more run-time parameters. If there is a parameter in any data type, it should be passed as a String equivalent.
1.3.6.1.4.1.4253.3.3.4.1.6DisplayString (SIZE(0..30))read-writemandatory
diagParam3
OBJECT-TYPE
The third parameter, if any to pass to the built-in test module. This parameter may be NULL to signify no more run-time parameters. If there is a parameter in any data type, it should be passed as a String equivalent.
1.3.6.1.4.1.4253.3.3.4.1.7DisplayString (SIZE(0..30))read-writemandatory
diagTSetMode
OBJECT-TYPE
If on, the given test will be run on the given card. The value off has no effect in this case and is ignored.
1.3.6.1.4.1.4253.3.3.4.1.8FlagTyperead-writemandatory
diagSelfTest
OBJECT-IDENTITY
1.3.6.1.4.1.4253.3.3.5
mcmescSelfTest
OBJECT-IDENTITY
1.3.6.1.4.1.4253.3.3.5.1
mcmescSelfTestTable
OBJECT-TYPE
This table represents the self-test results for mcmesc link port.
1.3.6.1.4.1.4253.3.3.5.1.1not-accessiblemandatory
mcmescSelfTestEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.3.3.5.1.1.1not-accessiblemandatory
mcmescSelfTestLocation
OBJECT-TYPE
The location of the card: local or remote. The self test is applicable to local mcmesc only.
1.3.6.1.4.1.4253.3.3.5.1.1.1.1CardLocationread-onlymandatory
mcmescSelfTestShelf
OBJECT-TYPE
The shelf in which the card is located.
1.3.6.1.4.1.4253.3.3.5.1.1.1.2CardShelfread-onlymandatory
mcmescSelfTestSlot
OBJECT-TYPE
The card slot in which the card is located.
1.3.6.1.4.1.4253.3.3.5.1.1.1.3CardSlotread-onlymandatory
mcmescSelfTestStart
OBJECT-TYPE
Initiate a self-test. A get on this will always return an other. Any outstanding loopbacks will be turned off before starting self-test.
1.3.6.1.4.1.4253.3.3.5.1.1.1.4INTEGER {other(1), yes(2)}read-writemandatory
mcmescSelfTestResult
OBJECT-TYPE
Indicate an overall result of the latest self-test. The value inprogress(3) will be given if a self-test is in progress. The table mcmescLinkSelfTestResult and mcmescPortSelfTestResult show the detail result of each individual test item.
1.3.6.1.4.1.4253.3.3.5.1.1.1.5INTEGER {passed(1), failed(2), inprogress(3), notreported(4)}read-onlymandatory
mcmescSelfTestSeqNum
OBJECT-TYPE
Indicate a sequece number associated with the latest complete self test. The sring of inprogress will be given if a self-test is in progress. The table mcmescLinkSelfTestResult and mcmescPortSelfTestResult show the detail result of each individual test item.
1.3.6.1.4.1.4253.3.3.5.1.1.1.6DisplayStringread-onlymandatory
mcmescSelfTestTimeStamp
OBJECT-TYPE
Indicate the time stamp associated with the latest complete self test. The value inprogress(3) will be given if a self-test is in progress. The table mcmescLinkSelfTestResult and mcmescPortSelfTestResult show the detail result of each individual test item.
1.3.6.1.4.1.4253.3.3.5.1.1.1.7DateAndTimeread-onlymandatory
mcmescLinkSelfTestResultTable
OBJECT-TYPE
This table represents the self-test results for mcmesc link port.
1.3.6.1.4.1.4253.3.3.5.1.2not-accessiblemandatory
mcmescLinkSelfTestResultEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.3.3.5.1.2.1not-accessiblemandatory
mcmescLinkSelfTestLocation
OBJECT-TYPE
The location of the card: local or remote. The self test is applicable to local mcmesc only.
1.3.6.1.4.1.4253.3.3.5.1.2.1.1CardLocationread-onlymandatory
mcmescLinkSelfTestShelf
OBJECT-TYPE
The shelf in which the card is located.
1.3.6.1.4.1.4253.3.3.5.1.2.1.2CardShelfread-onlymandatory
mcmescLinkSelfTestSlot
OBJECT-TYPE
The card slot in which the card is located.
1.3.6.1.4.1.4253.3.3.5.1.2.1.3CardSlotread-onlymandatory
mcmescLinkSelfTestTxI2c
OBJECT-TYPE
Indicate the link port's Tx I2C self-test result. The value inprogress(3) will be given if a self-test is in progress.
1.3.6.1.4.1.4253.3.3.5.1.2.1.4INTEGER {passed(1), failed(2), inprogress(3), notreported(4)}read-onlymandatory
mcmescLinkSelfTestCdrI2c
OBJECT-TYPE
Indicate the link port's CDR I2C self-test result. The value inprogress(3) will be given if a self-test is in progress.
1.3.6.1.4.1.4253.3.3.5.1.2.1.5INTEGER {passed(1), failed(2), inprogress(3), notreported(4)}read-onlymandatory
mcmescLinkSelfTestDataPath
OBJECT-TYPE
Indicate the link port's data path self-test result. The value inprogress(3) will be given if a self-test is in progress.
1.3.6.1.4.1.4253.3.3.5.1.2.1.6INTEGER {passed(1), failed(2), inprogress(3), notreported(4)}read-onlymandatory
mcmescPortSelfTestResultTable
OBJECT-TYPE
This table represents the self-test results for mcmesc CPE port.
1.3.6.1.4.1.4253.3.3.5.1.3not-accessiblemandatory
mcmescPortSelfTestResultEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.3.3.5.1.3.1not-accessiblemandatory
mcmescPortSelfTestLocation
OBJECT-TYPE
The location of the card: local or remote. The self test is applicable to local mcmesc only.
1.3.6.1.4.1.4253.3.3.5.1.3.1.1CardLocationread-onlymandatory
mcmescPortSelfTestShelf
OBJECT-TYPE
The shelf in which the card is located.
1.3.6.1.4.1.4253.3.3.5.1.3.1.2CardShelfread-onlymandatory
mcmescPortSelfTestSlot
OBJECT-TYPE
The card slot in which the card is located.
1.3.6.1.4.1.4253.3.3.5.1.3.1.3CardSlotread-onlymandatory
mcmescPortSelfTestPort
OBJECT-TYPE
The CPE port's index.
1.3.6.1.4.1.4253.3.3.5.1.3.1.4INTEGERread-onlymandatory
mcmescPortSelfTestTxI2c
OBJECT-TYPE
Indicate the CPE port's Tx I2C self-test result. The value inprogress(3) will be given if a self-test is in progress.
1.3.6.1.4.1.4253.3.3.5.1.3.1.5INTEGER {passed(1), failed(2), inprogress(3), notreported(4)}read-onlymandatory
mcmescPortSelfTestCdrI2c
OBJECT-TYPE
Indicate the CPE port's CDR I2C self-test result. The value inprogress(3) will be given if a self-test is in progress.
1.3.6.1.4.1.4253.3.3.5.1.3.1.6INTEGER {passed(1), failed(2), inprogress(3), notreported(4)}read-onlymandatory
mcmescPortSelfTestTxDataPath
OBJECT-TYPE
Indicate the CPE port's Tx data path self-test result. The value inprogress(3) will be given if a self-test is in progress.
1.3.6.1.4.1.4253.3.3.5.1.3.1.7INTEGER {passed(1), failed(2), inprogress(3), notreported(4)}read-onlymandatory
mcmescPortSelfTestRxDataPath
OBJECT-TYPE
Indicate the CPE port's Rx data path self-test result. The value inprogress(3) will be given if a self-test is in progress.
1.3.6.1.4.1.4253.3.3.5.1.3.1.8INTEGER {passed(1), failed(2), inprogress(3), notreported(4)}read-onlymandatory
alarmLog
OBJECT-IDENTITY
1.3.6.1.4.1.4253.3.4
alarmNumEvents
OBJECT-TYPE
Number of alarms logged in the table below. This counter is automatically set by the software. The max is 300 entries.
1.3.6.1.4.1.4253.3.4.1INTEGER (0..300)read-onlymandatory
alarmLogTable
OBJECT-TYPE
This table represents the information for the alarm log buffer
1.3.6.1.4.1.4253.3.4.2not-accessiblemandatory
alarmLogEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.3.4.2.1not-accessiblemandatory
alarmFirstDateTime
OBJECT-TYPE
The date and time for the first alarm occurrence.
1.3.6.1.4.1.4253.3.4.2.1.1DateAndTimeread-onlymandatory
alarmTag
OBJECT-TYPE
A unique tag used to identify the alarm entry.
1.3.6.1.4.1.4253.3.4.2.1.2INTEGER (1..999)read-onlymandatory
alarmLastDateTime
OBJECT-TYPE
The date and time for the most recent alarm occurrence. If this is the first time occurrence, it would be same as alarmFirstDateTime.
1.3.6.1.4.1.4253.3.4.2.1.3DateAndTimeread-onlymandatory
alarmEventId
OBJECT-TYPE
The event ID assigned to this alarm.
1.3.6.1.4.1.4253.3.4.2.1.4INTEGER (0..9999)read-onlymandatory
alarmSeverity
OBJECT-TYPE
The severity of this alarm. Could be critical, major, or minor.
1.3.6.1.4.1.4253.3.4.2.1.5INTEGER {critical(1), major(2), minor(3)}read-onlymandatory
alarmSource
OBJECT-TYPE
A five to seven tuple string composed of the following items: System Name:card type (MPM, OCMITU, OFCM, etc.). location (L for local, R[number] for remote with optional station number). shelf #. slot id[. port #][:link name(optional depending on card type)][:ring name (optional)] [:pathname(optional)]. When an event applies to all slots of the whole chassis, 0 will be displayed for both shelf and slot. Example: SystemInSunnyvale:OCMITU.L.1.6:ITU23
1.3.6.1.4.1.4253.3.4.2.1.6DisplayString (SIZE(0..152))read-onlymandatory
alarmDescr
OBJECT-TYPE
A string signifying the cause of the error in natural language (preferrably English) format.
1.3.6.1.4.1.4253.3.4.2.1.7DisplayString (SIZE(0..100))read-onlymandatory
alarmCnt
OBJECT-TYPE
Number of times alarm has occurred(from the same source).
1.3.6.1.4.1.4253.3.4.2.1.8INTEGERread-onlymandatory
alarmAck
OBJECT-TYPE
Acknowledge or unacknowledge the active alarm. Ack will remove its contribution to the external dry contact alarm closure. Default is unacknowledged.
1.3.6.1.4.1.4253.3.4.2.1.9INTEGER {acknowledged(1), unacknowledged(2)}read-writemandatory
alarmClear
OBJECT-TYPE
An action to clear the alarm from the alarm log. If alarm persists, another alarm will be sent. A GET operation would always return other(1).
1.3.6.1.4.1.4253.3.4.2.1.10INTEGER {other(1), clear(2)}read-writemandatory
alarmLastChange
OBJECT-TYPE
Time ticks in microseconds of when the last change was made to the alarm log. This includes ack/unack, clear, and alarm addition/deletion.
1.3.6.1.4.1.4253.3.4.3INTEGERread-onlymandatory
security
OBJECT-IDENTITY
1.3.6.1.4.1.4253.4
userSecMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.4253.4.1
usrNumUsers
OBJECT-TYPE
Number of user Logons in the table below. This counter is automatically set by the software.
1.3.6.1.4.1.4253.4.1.1INTEGER (0..999)read-onlymandatory
usrSecTable
OBJECT-TYPE
This table represents the information for each user logon entry.
1.3.6.1.4.1.4253.4.1.2not-accessiblemandatory
usrSecEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.4.1.2.1not-accessiblemandatory
usrSecLogonId
OBJECT-TYPE
The unique logon ID assigned to each user. This field should only be written by users that are in the right security role.
1.3.6.1.4.1.4253.4.1.2.1.1LogonIDread-writemandatory
usrSecPasswd
OBJECT-TYPE
The hashed password for each unique logon ID. To turn the user account off, typically the password is set to some fixed value. Fixed passwords are not accepted as valid passwords. Since this field is one-way hashed, it can be safely read without compromising the security of the system.
1.3.6.1.4.1.4253.4.1.2.1.2HashedPasswdread-writemandatory
usrSecRole
OBJECT-TYPE
The role associated with each user logon ID. This is an index into the system role(s) table.
1.3.6.1.4.1.4253.4.1.2.1.3INTEGERread-writemandatory
usrSecFullName
OBJECT-TYPE
The full name of the user associated with each unique logon ID.
1.3.6.1.4.1.4253.4.1.2.1.4DisplayString (SIZE(0..45))read-writemandatory
usrSecActDateTime
OBJECT-TYPE
The Time & Date of the user account activation.
1.3.6.1.4.1.4253.4.1.2.1.5DateAndTimeread-onlymandatory
usrSecLastDateTime
OBJECT-TYPE
The Time & Date of the last user logon to the system
1.3.6.1.4.1.4253.4.1.2.1.6DateAndTimeread-onlymandatory
usrSecSetLastDateTime
OBJECT-TYPE
An action to set the Time & Date of the last user logon to the current systemtime.
1.3.6.1.4.1.4253.4.1.2.1.7ResetTyperead-writemandatory
systemSecMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.4253.4.2
secNumRoles
OBJECT-TYPE
Number of system security roles in the table below. This counter is automatically set by the software.
1.3.6.1.4.1.4253.4.2.1INTEGER (0..9999)not-accessiblemandatory
secRoleTable
OBJECT-TYPE
This table represents the information for each system security role entry.
1.3.6.1.4.1.4253.4.2.2not-accessiblemandatory
secRoleEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.4.2.2.1not-accessiblemandatory
secRole
OBJECT-TYPE
Each row in this table defines a unique security role.
1.3.6.1.4.1.4253.4.2.2.1.1EntityNamenot-accessiblemandatory
secRoleDescr
OBJECT-TYPE
The full narrated description of each security Role.
1.3.6.1.4.1.4253.4.2.2.1.2DisplayString (SIZE(0..60))not-accessiblemandatory
secNumGroups
OBJECT-TYPE
Number of entity groups in the table below. This counter is automatically set by the software.
1.3.6.1.4.1.4253.4.2.3INTEGER (0..9999)not-accessiblemandatory
secGroupTable
OBJECT-TYPE
This table represents the information for each entity group entry.
1.3.6.1.4.1.4253.4.2.4not-accessiblemandatory
secGroupEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.4.2.4.1not-accessiblemandatory
secGroup
OBJECT-TYPE
Each row in this table defines a grouping of entities or elements from the MIB.
1.3.6.1.4.1.4253.4.2.4.1.1EntityNamenot-accessiblemandatory
secGroupRole
OBJECT-TYPE
The containment of this group within a security role. Under the given schema, each Role may have zero or more entity groups. Given an entity group, it may have been contained within one or more roles.
1.3.6.1.4.1.4253.4.2.4.1.2EntityNamenot-accessiblemandatory
secNumElements
OBJECT-TYPE
Number of elements or entities in the table below. This counter is automatically set by the software.
1.3.6.1.4.1.4253.4.2.5INTEGER (0..9999)not-accessiblemandatory
secElementTable
OBJECT-TYPE
This table represents the information for each entity or element in the MIB.
1.3.6.1.4.1.4253.4.2.6not-accessiblemandatory
secElementEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.4.2.6.1not-accessiblemandatory
secElement
OBJECT-TYPE
Each row in this table defines an element or entity from the MIB.
1.3.6.1.4.1.4253.4.2.6.1.1EntityNamenot-accessiblemandatory
secElementAccess
OBJECT-TYPE
The original access mode for this element from the MIB.
1.3.6.1.4.1.4253.4.2.6.1.2INTEGER {read(1), write(2), readWrite(3), none(4)}not-accessiblemandatory
secElementOID
OBJECT-TYPE
The original SNMP OID for this element from the MIB.
1.3.6.1.4.1.4253.4.2.6.1.3DisplayString (SIZE(0..30))not-accessiblemandatory
secElementType
OBJECT-TYPE
The original type for this element from the MIB.
1.3.6.1.4.1.4253.4.2.6.1.4INTEGER {element(1), group(2), table(3)}not-accessiblemandatory
secElementParent
OBJECT-TYPE
The original parent name for this element from the MIB. The parent is either a table or a subgroup.
1.3.6.1.4.1.4253.4.2.6.1.5EntityNamenot-accessiblemandatory
secNumElmntGrp
OBJECT-TYPE
Number of element-to-group mappings in the table below. This counter is automatically set by the software.
1.3.6.1.4.1.4253.4.2.7INTEGER (0..9999)not-accessiblemandatory
secElmntGrpTable
OBJECT-TYPE
This table represents the information for each element-to-group mapping.
1.3.6.1.4.1.4253.4.2.8not-accessiblemandatory
secElmntGrpEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.4.2.8.1not-accessiblemandatory
elmntName
OBJECT-TYPE
Each row in this table defines a mapping of elements to groups. This column is an index into the secElementTable.
1.3.6.1.4.1.4253.4.2.8.1.1EntityNamenot-accessiblemandatory
grpName
OBJECT-TYPE
Each row in this table defines a mapping of elements to groups. This column is an index into the secGroupTable.
1.3.6.1.4.1.4253.4.2.8.1.2EntityNamenot-accessiblemandatory
elmntGrpAccess
OBJECT-TYPE
The access mode assigned to each element/group entry. Under the given schema, each group may have zero or more MIB elements. Given an element, it may have been contained within one or more groups. The access mode specified here defines what is the granted access mode to the named element contained in this group. Note, the granted access right can never exceed that of the actual MIB access privilege.
1.3.6.1.4.1.4253.4.2.8.1.3INTEGER {read(1), write(2), readWrite(3), none(4)}not-accessiblemandatory
netSecMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.4253.4.3
radiusSecMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.4253.4.3.1
radiusAuthOrder
OBJECT-TYPE
The authentication order used when validating a user login id and password.
1.3.6.1.4.1.4253.4.3.1.1INTEGER {local(1), radius(2), localRadius(3), radiusLocal(4)}read-writemandatory
radiusNasIdentifier
OBJECT-TYPE
NAS-Identifier for the MPM.
1.3.6.1.4.1.4253.4.3.1.2DisplayString (SIZE(0..32))read-writemandatory
radiusDefaultRealm
OBJECT-TYPE
Default realm used for radius authentication. This realm is not used for local authentication.
1.3.6.1.4.1.4253.4.3.1.3DisplayString (SIZE(0..32))read-writemandatory
radiusTimeout
OBJECT-TYPE
Timeout when sending an authentication request to a radius server.
1.3.6.1.4.1.4253.4.3.1.4INTEGER (1..60)read-writemandatory
radiusRetries
OBJECT-TYPE
Number of times to resend requests when a timeout occurs.
1.3.6.1.4.1.4253.4.3.1.5INTEGER (1..10)read-writemandatory
radiusSecTable
OBJECT-TYPE
Radius server table.
1.3.6.1.4.1.4253.4.3.1.6not-accessiblemandatory
radiusSecEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.4.3.1.6.1not-accessiblemandatory
radiusServerIndex
OBJECT-TYPE
Index into the radius server table. This index also specifies the server order used for sending authentication requests.
1.3.6.1.4.1.4253.4.3.1.6.1.1INTEGERread-onlymandatory
radiusServerAddress
OBJECT-TYPE
IP address of the radius server. Setting the address to 0 will delete the server entry.
1.3.6.1.4.1.4253.4.3.1.6.1.2IpAddressread-writemandatory
radiusServerPort
OBJECT-TYPE
Radius port used for authentication requests.
1.3.6.1.4.1.4253.4.3.1.6.1.3INTEGERread-writemandatory
radiusServerSecret
OBJECT-TYPE
Secret shared with authentication server.
1.3.6.1.4.1.4253.4.3.1.6.1.4DisplayString (SIZE(1..48))read-writemandatory
radiusAddServer
OBJECT-TYPE
Add server to the server table. Servers are added to the first available entry in the server table. To add a server provide server IP address, radius port, and shared secret in the format '<ip address>,<port>, <secret>'. All fields are required. a get on this element will return '0,0,0'.
1.3.6.1.4.1.4253.4.3.1.7DisplayStringread-writemandatory
sshSecMgmt
OBJECT-IDENTITY
1.3.6.1.4.1.4253.4.3.2
sshMode
OBJECT-TYPE
Enables or disables the SSH server. Enabling SSH will disable the built in telnet server. Disabling SSH will enable the telnet server.
1.3.6.1.4.1.4253.4.3.2.1INTEGER {enabled(1), disabled(2)}read-writemandatory
sshKeySize
OBJECT-TYPE
The size (in bits) of the DSS key to generate. Key size must be a multiple of 8 and between 512 and 1024 bits.
1.3.6.1.4.1.4253.4.3.2.2INTEGER (512..1024)read-writemandatory
sshMaxSessions
OBJECT-TYPE
The maximum number of SSH sessions that can be active at one time. Setting this element will also affect the number of telnet sessions that can be active at a time.
1.3.6.1.4.1.4253.4.3.2.3INTEGER (1..6)read-writemandatory
sshGenKey
OBJECT-TYPE
Setting this element to genDssKey(2) will cause a new DSS key to be generated. The process of generating a new key can take some time (several minutes) and may cause significant system slowdown until the process is complete. Reading this element will always return other(1).
1.3.6.1.4.1.4253.4.3.2.4INTEGER {other(1), genDssKey(2)}read-writemandatory
accounting
OBJECT-IDENTITY
1.3.6.1.4.1.4253.5
cpAcct
OBJECT-IDENTITY
1.3.6.1.4.1.4253.5.1
acctCPTable
OBJECT-TYPE
This table represents the information for each system accounting data maintained for each CP.
1.3.6.1.4.1.4253.5.1.1not-accessiblemandatory
acctCPEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.5.1.1.1not-accessiblemandatory
acctCPShelf
OBJECT-TYPE
The shelf in which the given CP card is placed.
1.3.6.1.4.1.4253.5.1.1.1.1CardShelfread-onlymandatory
acctCPSlot
OBJECT-TYPE
The slot in which the given CP card is placed.
1.3.6.1.4.1.4253.5.1.1.1.2CardSlotread-onlymandatory
acctCPDsgnAct
OBJECT-TYPE
The total time this CP has been designated Active
1.3.6.1.4.1.4253.5.1.1.1.3Counternot-accessiblemandatory
acctCPDsgnStdby
OBJECT-TYPE
The total time this CP has been designated Standby
1.3.6.1.4.1.4253.5.1.1.1.4Counternot-accessiblemandatory
acctCPActive
OBJECT-TYPE
The total time this CP has actually been the primary
1.3.6.1.4.1.4253.5.1.1.1.5Counterread-onlymandatory
acctCPStandby
OBJECT-TYPE
The total time this CP has actually been the standby
1.3.6.1.4.1.4253.5.1.1.1.6Counterread-onlymandatory
acctCPUpTime
OBJECT-TYPE
The total time since this CP has been commissioned
1.3.6.1.4.1.4253.5.1.1.1.7Counterread-onlymandatory
acctCPUnAvail
OBJECT-TYPE
The total time this CP has not been available due to an alarm, diag testing or being put offline
1.3.6.1.4.1.4253.5.1.1.1.8Counterread-onlymandatory
acctCPResetCntrs
OBJECT-TYPE
If reset, the CP accounting counters will be reset to 0. A get on this will always return other.
1.3.6.1.4.1.4253.5.1.1.1.9ResetTyperead-writemandatory
ccAcct
OBJECT-IDENTITY
1.3.6.1.4.1.4253.5.2
acctCCTable
OBJECT-TYPE
This table represents the information for each system accounting data maintained for each CC.
1.3.6.1.4.1.4253.5.2.1not-accessiblemandatory
acctCCEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.5.2.1.1not-accessiblemandatory
acctCCLocation
OBJECT-TYPE
The location of the CC card: local or remote.
1.3.6.1.4.1.4253.5.2.1.1.1CardLocationread-onlymandatory
acctCCShelf
OBJECT-TYPE
The shelf in which the given CC card is placed.
1.3.6.1.4.1.4253.5.2.1.1.2CardShelfread-onlymandatory
acctCCSlot
OBJECT-TYPE
The slot in which the given CC card is placed.
1.3.6.1.4.1.4253.5.2.1.1.3CardSlotread-onlymandatory
acctCCUpTime
OBJECT-TYPE
The total time since this CC has been commissioned
1.3.6.1.4.1.4253.5.2.1.1.4Counterread-onlymandatory
acctCCUnAvail
OBJECT-TYPE
The total time this CC has not been available due to an alarm, diag testing or being put offline
1.3.6.1.4.1.4253.5.2.1.1.5Counterread-onlymandatory
acctCCResetCntrs
OBJECT-TYPE
If reset, the CC accounting counters will be reset to 0. A get on this will always return other.
1.3.6.1.4.1.4253.5.2.1.1.6ResetTyperead-writemandatory
mcmAcct
OBJECT-IDENTITY
1.3.6.1.4.1.4253.5.3
acctmcmTable
OBJECT-TYPE
This table represents the information for each system accounting data maintained for each MCMT1/MCME1.
1.3.6.1.4.1.4253.5.3.1not-accessiblemandatory
acctmcmEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.5.3.1.1not-accessiblemandatory
acctmcmLocation
OBJECT-TYPE
The location of the MCMT1/MCME1 card: local or remote.
1.3.6.1.4.1.4253.5.3.1.1.1CardLocationread-onlymandatory
acctmcmShelf
OBJECT-TYPE
The shelf in which the given MCMT1/MCME1 card is placed.
1.3.6.1.4.1.4253.5.3.1.1.2CardShelfread-onlymandatory
acctmcmSlot
OBJECT-TYPE
The slot in which the given MCMT1/MCME1 card is placed.
1.3.6.1.4.1.4253.5.3.1.1.3CardSlotread-onlymandatory
acctmcmUpTime
OBJECT-TYPE
The total time since this MCMT1/MCME1 has been commissioned
1.3.6.1.4.1.4253.5.3.1.1.4Counterread-onlymandatory
acctmcmUnAvail
OBJECT-TYPE
The total time this MCMT1/MCME1 has not been available due to an alarm, diag testing or being put offline
1.3.6.1.4.1.4253.5.3.1.1.5Counterread-onlymandatory
acctmcmResetCntrs
OBJECT-TYPE
If reset, the MCMT1/MCME1 accounting counters will be reset to 0. A get on this will always return other.
1.3.6.1.4.1.4253.5.3.1.1.6ResetTyperead-writemandatory
mcmescAcct
OBJECT-IDENTITY
1.3.6.1.4.1.4253.5.4
acctmcmescTable
OBJECT-TYPE
This table represents the information for each system accounting data maintained for each MCMESC.
1.3.6.1.4.1.4253.5.4.1not-accessiblemandatory
acctmcmescEntry
OBJECT-TYPE
Specifies the index for each row in the table below
1.3.6.1.4.1.4253.5.4.1.1not-accessiblemandatory
acctmcmescLocation
OBJECT-TYPE
The location of the MCMESC card: local or remote.
1.3.6.1.4.1.4253.5.4.1.1.1CardLocationread-onlymandatory
acctmcmescShelf
OBJECT-TYPE
The shelf in which the given MCMESC card is placed.
1.3.6.1.4.1.4253.5.4.1.1.2CardShelfread-onlymandatory
acctmcmescSlot
OBJECT-TYPE
The slot in which the given MCMESC card is placed.
1.3.6.1.4.1.4253.5.4.1.1.3CardSlotread-onlymandatory
acctmcmescUpTime
OBJECT-TYPE
The total time since this MCMESC has been commissioned.
1.3.6.1.4.1.4253.5.4.1.1.4Counterread-onlymandatory
acctmcmescUnAvail
OBJECT-TYPE
The total time this MCMESC has not been available due to an alarm, diag testing or being put offline.
1.3.6.1.4.1.4253.5.4.1.1.5Counterread-onlymandatory
acctmcmescResetCntrs
OBJECT-TYPE
If reset, the MCMESC accounting counters will be reset to 0. A get on this will always return other.
1.3.6.1.4.1.4253.5.4.1.1.6ResetTyperead-onlymandatory

Notifications

NameOIDStatus
luxNGenericTrap
NOTIFICATION-TYPE
This is a generic trap identifying an event for a given event source. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.1
luxNVoadmDetectorFailureTrap
NOTIFICATION-TYPE
This trap is sent when a failure is detected on the VOADM power monitor. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.1001
luxNVoadmDetectorFailureResolvedTrap
NOTIFICATION-TYPE
This trap is sent when a failure on the VOADM power monitor has been resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.1002
luxNVoadmOutofRangeTrap
NOTIFICATION-TYPE
This trap is sent when the user configured settings for a VOADM would force the power levels to be outside of allowed operating ranges for the current link conditions. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.1003
luxNVoadmOutofRangeResolvedTrap
NOTIFICATION-TYPE
This trap is sent when an existing VOADM out of range condition is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.1004
luxNsignalStrengthHighTrap
NOTIFICATION-TYPE
This trap is sent when the receieve signal strength is high. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.1005
luxNsignalStrengthLowTrap
NOTIFICATION-TYPE
This trap is sent when the receieve signal strength is low. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.1006
luxNsignalStrengthNormalTrap
NOTIFICATION-TYPE
This trap is sent when the receieve signal strength is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.1007
luxNlaserPowerOutOfRangeTrap
NOTIFICATION-TYPE
This trap is sent upon detection of out of range laser power. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.1008
luxNlaserPowerNormalTrap
NOTIFICATION-TYPE
This trap is sent upon detection of normal laser power. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.1009
luxNberHighThresholdExceeded
NOTIFICATION-TYPE
This trap is sent upon detecting that MCMESC's BER high threshold is exceeds. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.1010
luxNberHighThresholdExceededNormal
NOTIFICATION-TYPE
This trap is sent upon detecting that MCMESC's BER high threshold is not exceeded. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.1011
luxNberModerateThresholdExceeded
NOTIFICATION-TYPE
This trap is sent upon detecting that MCMESC's BER moderate threshold is exceeded. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.1012
luxNberModerateThresholdExceededNormal
NOTIFICATION-TYPE
This trap is sent upon detecting that MCMESC's BER moderate threshold is not exceeded. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.1013
luxNSNMPKeepalive
NOTIFICATION-TYPE
This trap is sent out periodicly by the MPM when SNMP keep alive functionality is enabled.
1.3.6.1.4.1.4253.0.2000
luxNSNMPKeepalivesEnabled
NOTIFICATION-TYPE
This trap is sent upon SNMP keep alive functionality being enabled
1.3.6.1.4.1.4253.0.2001
luxNSNMPKeepalivesDisabled
NOTIFICATION-TYPE
This trap is sent upon SNMP keep alive functionality being disabled
1.3.6.1.4.1.4253.0.2002
luxNSNMPKeepaliveIntervalChanged
NOTIFICATION-TYPE
This trap is sent when the SNMP keep alive interval is modified
1.3.6.1.4.1.4253.0.2003
luxNTelnetClientEnabled
NOTIFICATION-TYPE
Telnet client has been enabled for active telnet sessions
1.3.6.1.4.1.4253.0.2004
luxNTelnetClientDisabled
NOTIFICATION-TYPE
Telnet client has been disabled for active telnet sessions
1.3.6.1.4.1.4253.0.2005
luxNsnmpAuthenticationFailureTrap
NOTIFICATION-TYPE
This trap is sent upon receipt of invalid community strings. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2017
luxNcoldStartTrap
NOTIFICATION-TYPE
This trap is sent when the device has reinitialized itself. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2018
luxNwarmStartTrap
NOTIFICATION-TYPE
This trap is sent when the device has undergone a warm boot. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2019
luxNlossOfLightResolvedTrap
NOTIFICATION-TYPE
This trap is sent when a loss of light condition has been resolved. For OCM/MCMT1/MCME1, it indicates that the link between two optically connected channel cards is up. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2021
luxNlossOfLightDetectedTrap
NOTIFICATION-TYPE
This trap is sent when a loss of light condition has been detected. For OCM/MCMT1/MCME1, it indicates that the link between two optically connected channel cards is down. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2022
luxNntpEnableTrap
NOTIFICATION-TYPE
This trap is sent when NTP is enabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2023
luxNntpDisableTrap
NOTIFICATION-TYPE
This trap is sent when NTP is disabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2024
luxNntpTimeServerChangedTrap
NOTIFICATION-TYPE
This trap is sent when the NTP time server is changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2025
luxNntpUpdateIntervalChangedTrap
NOTIFICATION-TYPE
This trap is sent when the NTP update interval is changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2026
luxNtimeZoneChangedTrap
NOTIFICATION-TYPE
This trap is sent when the system time zone is changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2027
luxNspiConnectionUpTrap
NOTIFICATION-TYPE
Obsolete. This trap is sent when SPI communications has been established with a card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2030
luxNcardLostTrap
NOTIFICATION-TYPE
This trap is sent when SPI communications has been lost with a card specified in the source field. The reason is either that the card has been physically removed or there exist a failure condition. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2031
luxNConfigChangeTrap
NOTIFICATION-TYPE
This trap is sent when a configuration change has ocurred for a card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2034
luxNstatsPollFailedTrap
NOTIFICATION-TYPE
This trap is sent when statistics data can no longer be gathered from a card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2035
luxNCardFoundTrap
NOTIFICATION-TYPE
This trap is sent when a card has been discovered in the chassis. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2040
luxNlocalLoopbackEnabledTrap
NOTIFICATION-TYPE
This trap is sent when the local loopback mode has been enabled for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2041
luxNremoteLoopbackEnabledTrap
NOTIFICATION-TYPE
This trap is sent when the remote loopback mode has been enabled for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2042
luxNlocalLoopbackDisabledTrap
NOTIFICATION-TYPE
This trap is sent when the local loopback mode has been disabled for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2043
luxNremoteLoopbackDisabledTrap
NOTIFICATION-TYPE
This trap is sent when the remote loopback mode has been disabled for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2044
luxNftpSessionInitiatedTrap
NOTIFICATION-TYPE
This trap is sent when a ftp session has been initiated from the CLI. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2047
luxNuserResetStatusTrap
NOTIFICATION-TYPE
Obsolete. This trap is sent when the status information for a card specified in the source field has been modified via the snmp agent. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2050
luxNprotectionSwitchTrap
NOTIFICATION-TYPE
This trap is sent when a protection switch has occurred either automatically or manually. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2051
luxNipAddressErrorTrap
NOTIFICATION-TYPE
Obsolete. This trap is sent when an error has occurred while configuring the IP address. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2052
luxNipNetmaskErrorTrap
NOTIFICATION-TYPE
Obsolete. This trap is sent when an error has occurred while configuring the Netmask. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2053
luxNdefaultGatewayErrorTrap
NOTIFICATION-TYPE
Obsolete. This trap is sent when an error has occurred while configuring the default gateway. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2054
luxNlossOfSignalTrap
NOTIFICATION-TYPE
This trap is sent when a loss of signal is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2055
luxNlossOfSignalNormalTrap
NOTIFICATION-TYPE
This trap is sent when a loss of signal problem on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2056
luxNlossOfFrameTrap
NOTIFICATION-TYPE
This trap is sent when a loss of frame error condition is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2057
luxNlossOfFrameNormalTrap
NOTIFICATION-TYPE
This trap is sent when a loss of frame error condition on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2058
luxNrecvAISTrap
NOTIFICATION-TYPE
This trap is sent when a receive AIS (Alarm Indication Signal) is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2059
luxNrecvAISNormalTrap
NOTIFICATION-TYPE
This trap is sent when a receive AIS (Alarm Indication Signal) problem on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2060
luxNrecvYellowAlarmTrap
NOTIFICATION-TYPE
This trap is sent when a receive receive yellow alarm is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2061
luxNrecvYellowAlarmNormalTrap
NOTIFICATION-TYPE
This trap is sent when a receive receive yellow alarm problem on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2062
luxNlineCodeViolationTrap
NOTIFICATION-TYPE
This trap is sent when a line code violation error condition is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2063
luxNlineCodeViolationNormalTrap
NOTIFICATION-TYPE
This trap is sent when a line code violation error condition on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2064
luxNframingAlarmTrap
NOTIFICATION-TYPE
This trap is sent when a framing alarm is detected on one of the ports on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2065
luxNframingAlarmNormalTrap
NOTIFICATION-TYPE
This trap is sent when a framing alarm problem on one of the ports on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2066
luxNlossOfTimingTrap
NOTIFICATION-TYPE
This trap is sent when a loss of timing condition is detected on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2067
luxNlossOfTimingNormalTrap
NOTIFICATION-TYPE
This trap is sent when a loss of timing problem on a channel card specified in the source field has been corrected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2068
luxNselfTestFailTrap
NOTIFICATION-TYPE
This trap is sent when a self-test failure is detected on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2073
luxNselfTestPassTrap
NOTIFICATION-TYPE
This trap is sent when a successful self-test is detected on a channel card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2074
luxNIbmDownTrap
NOTIFICATION-TYPE
This trap is sent when a problem is detected on a inband management link. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2075
luxNIbmNormalTrap
NOTIFICATION-TYPE
This trap is sent when a problem is resolved on a inband management link. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2076
luxNnearendCardLoopbackEnabledTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a near-end card loopback has been enabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2077
luxNnearendCardLoopbackDisabledTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a near-end card loopback has been disabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2078
luxNnetworkPortLoopbackEnabledTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a network port loopback has been enabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2079
luxNnetworkPortLoopbackDisabledTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a network port loopback has been disabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2080
luxNnetworkCardLoopbackEnabledTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a network card loopback has been enabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2081
luxNnetworkCardLoopbackDisabledTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a network card loopback has been disabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2082
luxNnearendPortLoopbackEnabledTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a nearend port loopback has been enabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2083
luxNnearendPortLoopbackDisabledTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a nearend port loopback has been disabled on an mcmt1/mcme1 or mcmesc card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2084
luxNpowerSupplyNotPresentTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the power supply specified in the source field is not present. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2085
luxNpowerSupplyOKTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the power supply specified in the source field is performing properly. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2086
luxNpowerSupplyDegradedTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the performance of the power supply specified in the source field has degraded. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2087
luxNpowerSupplyFailureTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the power supply specified in the source field has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2088
luxNfanOKTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the fan specified in the source field is performing properly. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2089
luxNfanFailureTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the fan specified in the source field has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2090
luxNcsimDataUnavailableTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the ColorSIM module as specified in the source field is in a Data Unavailable state. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2091
luxNcsimDataAvailableTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the ColorSIM module as specified in the source field is in a Data Available state. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2092
luxNcsimModuleFailureTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the ColorSIM module as specified in the source field has failed to operate properly. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2093
luxNethernetLossOfCarrierTrap
NOTIFICATION-TYPE
This trap is sent to indicate that loss of carrier has been detected on the CPE's ethernet port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2094
luxNethernetCarrierDetectedTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the carrier has been detected on the CPE's ethernet port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2095
luxNtimingPriorityChangedTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the timing priority for a card has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2096
luxNopenFiberCPEAlarmTrap
NOTIFICATION-TYPE
This trap is sent when an open fiber condition on the CPE has been detected from a card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2097
luxNopenFiberCPEAlarmResolvedTrap
NOTIFICATION-TYPE
This trap is sent when an open fiber condition on the CPE has been resolved from a card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2098
luxNstandbyMPMDetectedTrap
NOTIFICATION-TYPE
This trap is sent when the standby MPM card has been detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2099
luxNstandbyMPMLostTrap
NOTIFICATION-TYPE
This trap is sent when the standby MPM card has been lost. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2100
luxNprotectionLinkFailureTrap
NOTIFICATION-TYPE
This trap is sent when the protection link has become unaviable due to either low receive power level or an open fiber condition. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2101
luxNprotectionLinkFailureResolvedTrap
NOTIFICATION-TYPE
This trap is sent when the protection link has become available as a result of a corrective action to resolve a previous failure condition. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2102
luxNtopologyDatabaseChangedTrap
NOTIFICATION-TYPE
This trap is sent whenever a link has either been added or deleted from the topology database. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2103
luxNredundantDatabaseCopyComplete
NOTIFICATION-TYPE
This trap is sent upon completion of a forced redundant database copy. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2104
luxNredundantDatabaseCopyFailed
NOTIFICATION-TYPE
This trap is sent when a failure occurs during a forced redundant database copy. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2105
luxNimageExportInProgressTrap
NOTIFICATION-TYPE
This trap is sent when an module image is being exported from the MPM through ftp. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2106
luxNimageExportSuccessTrap
NOTIFICATION-TYPE
This trap is sent when a module image exported from the MPM through ftp has been completed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2107
luxNimageExportFailedTrap
NOTIFICATION-TYPE
This trap is sent when a module image exported from the MPM through ftp has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2108
luxNunknownCardTypeDetectedTrap
NOTIFICATION-TYPE
This trap is sent when a module with an unknown card type is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2109
luxNosamBiasCurrentOverLimitTrap
NOTIFICATION-TYPE
This trap is sent when the osam's bias current exceeds 90% of allowed maximum. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2110
luxNosamBiasCurrentNormal
NOTIFICATION-TYPE
This trap is sent when the osam's bias current is within normal range. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2111
luxNosamTecCurrentOverLimit
NOTIFICATION-TYPE
This trap is sent when the osam's TEC current is above the specified limit. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2112
luxNosamTecCurrentNormal
NOTIFICATION-TYPE
This trap is sent when the osam's TEC current is within normal range. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2113
luxNosamLaserTemperatureDrift
NOTIFICATION-TYPE
This trap is sent when the osam's laser temperature drifts by more than +/- 2 degree Celsius. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2114
luxNosamLaserTemperatureStable
NOTIFICATION-TYPE
This trap is sent when the osam's laser temperature no longer drifts. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2115
luxNosamMaxInputPowerReached
NOTIFICATION-TYPE
This trap is sent when the osam's input power is greater than or equal to 9 dBm. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2116
luxNosamInputPowerBackDownNormal
NOTIFICATION-TYPE
This trap is sent when the osam's input power has fallen within normal range. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2117
luxNosamMaxOutputPowerReached
NOTIFICATION-TYPE
This trap is sent when the osam's output power is greater than or equal to 13 dBm. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2118
luxNosamOutputPowerNormal
NOTIFICATION-TYPE
This trap is sent when the osam's output power is within normal range. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2119
luxNosamOpticalGainDeltaExceeded
NOTIFICATION-TYPE
This trap is sent when the osam's gain delta is greater than or equal to 4 dB. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2120
luxNosamOpticalGainDeltaNormal
NOTIFICATION-TYPE
This trap is sent when the osam's gain delta is less than 4 dB. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2121
luxNosamMinInputPowerBelowLimit
NOTIFICATION-TYPE
This trap is sent when the osam's input power is less than or equal to -30 dBm. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2122
luxNosamInputPowerBackUpNormal
NOTIFICATION-TYPE
This trap is sent when the osam's input power has risen within normal range. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2123
luxNosamSingleAprSensorFailed
NOTIFICATION-TYPE
This trap is sent when the osam's APR sensor is not functioning. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2124
luxNosamSingleAprSensorNormal
NOTIFICATION-TYPE
This trap is sent when the osam's APR sensor has become functional. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2125
luxNosamDualAprSensorFailed
NOTIFICATION-TYPE
This trap is sent when both of the osam's APR sensors are not functioning. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2126
luxNosamDualAprSensorNormal
NOTIFICATION-TYPE
This trap is sent when both of the osam's APR sensors has become functional. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2127
luxNosamFiberDisconnected
NOTIFICATION-TYPE
This trap is sent when a fiber disconnect condition has been detected on an osam module. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2128
luxNosamFiberConnected
NOTIFICATION-TYPE
This trap is sent when a fiber connect condition has been detected after a fiber disconnect on an osam module. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2129
luxNosamControlChanged
NOTIFICATION-TYPE
This trap is sent when either the current control or gain control has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2130
luxNosamLaserModuleOn
NOTIFICATION-TYPE
This trap is sent when the laser module has been turned on by the osam firmware. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2131
luxNosamLaserModuleOff
NOTIFICATION-TYPE
This trap is sent when the laser module has been turned off by the osam firmware. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2132
luxNipAuthenticationFailure
NOTIFICATION-TYPE
Not yet supported. This trap is sent when access from an invalid IP address based on the ACL has been detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2133
luxNftpCompletedTrap
NOTIFICATION-TYPE
This trap is sent when the ftp session has been disconnected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2134
luxNftpHostFailedTrap
NOTIFICATION-TYPE
This trap is sent when the MPM is unable to connect to the ftp host. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2135
luxNimageUpdateInProgressTrap
NOTIFICATION-TYPE
This trap is sent when an module image is being downloaded to MPM through ftp. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2136
luxNimageUpdateSuccessTrap
NOTIFICATION-TYPE
This trap is sent when a module image download to MPM through ftp has been completed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2137
luxNimageUpdateFailedTrap
NOTIFICATION-TYPE
This trap is sent when a module image download to MPM through ftp has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2138
luxNmoduleUpdateInProgressTrap
NOTIFICATION-TYPE
This trap is sent when a module image is being transferred from the MPM to the module. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2139
luxNmoduleUpdateSuccessTrap
NOTIFICATION-TYPE
This trap is sent when a module image transfer from the MPM to the module has been completed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2140
luxNmoduleUpdateFailedTrap
NOTIFICATION-TYPE
This trap is sent when a module image transfer from the MPM to the module has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2141
luxNethernetLinkFailure
NOTIFICATION-TYPE
This trap is sent upon detection of the ethernet link failure on the MPM. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2142
luxNethernetLinkFailureResolved
NOTIFICATION-TYPE
This trap is sent upon resolution of the ethernet link failure on the MPM. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2143
luxNfanNotPresentTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the fan specified in the source field is not present in the system. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2144
luxNcardMismatchTrap
NOTIFICATION-TYPE
This trap is sent when a card mismatch is found in a given slot. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2145
luxNpwrFeedLowVoltageTrap
NOTIFICATION-TYPE
This trap is sent when the DC voltage level on the power feed reaches very close to the shutdown voltage. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2146
luxNpwrFeedLowVoltageRecoveryTrap
NOTIFICATION-TYPE
This trap is sent when the DC voltage level on the power feed recovers from the low voltage level condition . The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2147
luxNpwrFeedOKTrap
NOTIFICATION-TYPE
This trap is sent when the DC voltage level on the power feed is within the operating window of the chassis . The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2148
luxNpwrFeedFailureTrap
NOTIFICATION-TYPE
This trap is sent when the DC voltage level on the power feed is either too low or too high to operate the chassis The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2149
luxNpwrFeedBrkOpenTrap
NOTIFICATION-TYPE
This trap is sent when a user manually flips open the breaker relay switch attached to that feed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2150
luxNextCritAlmInpTrap
NOTIFICATION-TYPE
This trap is sent when an alarm gets generated at an external alarm input that is configured for critical severity. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2151
luxNextMajAlmInpTrap
NOTIFICATION-TYPE
This trap is sent when an alarm gets generated at an external alarm input that is configured for majority severity. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2152
luxNextMinorAlmInpTrap
NOTIFICATION-TYPE
This trap is sent when an alarm gets generated at an external alarm input that is configured for minor severity. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2153
luxNextClearAlmInpTrap
NOTIFICATION-TYPE
This trap is sent when an alarm gets cleared at an external alarm input. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2154
luxNpwrFeedOverVoltageTrap
NOTIFICATION-TYPE
This trap is sent when the DC voltage level on the power feed reaches very close to the shutdown voltage on the higher side. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2155
luxNpwrFeedOverVoltageRecoveryTrap
NOTIFICATION-TYPE
This trap is sent when the DC voltage level on the power feed recovers from the over voltage level condition . The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2156
luxNstandbySWMismatchTrap
NOTIFICATION-TYPE
This trap is sent when there is a mismatch between the software version of standby and active MPM. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2157
luxNstandbyDBNotSupportedTrap
NOTIFICATION-TYPE
This trap is sent when the standby MPM do not support Active MPM's database. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2158
luxNactiveStandbySWAlignedTrap
NOTIFICATION-TYPE
This trap is sent when the software version between standby and active MPM is aligned. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2159
luxNactiveStandbyDBAlignedTrap
NOTIFICATION-TYPE
This trap is sent when the database version between standby and active MPM is aligned. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2160
luxNmcmescTestSequenceOnTrap
NOTIFICATION-TYPE
This trap is sent when the test-sequence is set to ON on an MCMESC card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2161
luxNmcmescTestSequenceOffTrap
NOTIFICATION-TYPE
This trap is sent when the test-sequence is set to OFF on an MCMESC card specified in the source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. The port number 1 to 12 is applicable to CPE ports, a NULL port number indicates the link. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2162
luxNselfTestStartedTrap
NOTIFICATION-TYPE
This trap is sent when self-test has started for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2163
luxNselfTestEndedTrap
NOTIFICATION-TYPE
This trap is sent when self-test has ended for a channel card in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2164
luxNvoadmMuxSetPointOutOfRange
NOTIFICATION-TYPE
This trap is sent when a VOADM module has detected that the recently configured mux set point value would bring down the fibre if applied. The set point value is rejected and the MPM and module returns to the previously configured mux set point. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2165
luxNvoadmDemuxForceConfig
NOTIFICATION-TYPE
This trap is sent when a VOADM module forces its Demux configuration into fixed power mode. Forcing the Demux mode to fixed power mode can only occur when the Demux ports are configured for fixed attentuation mode and network conditions change sufficently that the current configuration may cause damage to the laser. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2166
luxNSfpNotPresent
NOTIFICATION-TYPE
This trap is sent when a missing SFP is detect. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2167
luxNSfpPresent
NOTIFICATION-TYPE
This trap is sent when a SFP has been inserted into the module .The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2168
luxNSfpFailure
NOTIFICATION-TYPE
This trap is sent when a SFP failure is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2169
luxNSfpFailureResolved
NOTIFICATION-TYPE
This trap is sent when a SFP failure is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2170
luxNSfpNotAuthorized
NOTIFICATION-TYPE
This trap is sent when an unauthorized SFP is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2171
luxNSfpAuthorized
NOTIFICATION-TYPE
This trap is sent when an unauthorized SFP is replaced with an authorized SFP. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2172
luxNSfpRateMismatch
NOTIFICATION-TYPE
This trap is sent when a SFP does not supported the user configured line rate. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2173
luxNSfpRateMismatchResolved
NOTIFICATION-TYPE
This trap is sent when a SFP that does not support the user configured line rate is replaced with an SFP that does. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2174
luxNLinkRxSignalDegraded
NOTIFICATION-TYPE
This trap is sent when the packet error rate increases over 10e-4. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2175
luxNLinkRxSignalDegradedResolved
NOTIFICATION-TYPE
This trap is sent when the packet error rate falls below 10e-4. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2176
luxNLinkTxFault
NOTIFICATION-TYPE
This trap is sent when a Tx fault is detect on the link port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2177
luxNLinkTxFaultResolved
NOTIFICATION-TYPE
This trap is sent when a Tx fault is resolved on the link port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2178
luxNPortTxFault
NOTIFICATION-TYPE
This trap is sent when a Tx fault is detect on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2179
luxNPortTxFaultResolved
NOTIFICATION-TYPE
This trap is sent when a Tx fault is resolved on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2180
luxNXfpNotPresent
NOTIFICATION-TYPE
This trap is sent when a missing XFP is detect. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2181
luxNXfpPresent
NOTIFICATION-TYPE
This trap is sent when a XFP has been inserted into the module .The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2182
luxNXfpFailure
NOTIFICATION-TYPE
This trap is sent when a XFP failure is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2183
luxNXfpFailureResolved
NOTIFICATION-TYPE
This trap is sent when a XFP failure is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2184
luxNXfpNotAuthorized
NOTIFICATION-TYPE
This trap is sent when an unauthorized XFP is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2185
luxNXfpAuthorized
NOTIFICATION-TYPE
This trap is sent when an unauthorized XFP is replaced with an authorized XFP. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2186
luxNXfpRateMismatch
NOTIFICATION-TYPE
This trap is sent when a XFP does not supported the user configured line rate. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2187
luxNXfpRateMismatchResolved
NOTIFICATION-TYPE
This trap is sent when a XFP that does not support the user configured line rate is replaced with a XFP that does. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2188
luxNCpeXfpNotPresent
NOTIFICATION-TYPE
This trap is sent when a missing XFP is detect for a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2189
luxNCpeXfpPresent
NOTIFICATION-TYPE
This trap is sent when a XFP has been inserted into the module CPE port.The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2190
luxNCpeXfpFailure
NOTIFICATION-TYPE
This trap is sent when a CPE XFP failure is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2191
luxNCpeXfpFailureResolved
NOTIFICATION-TYPE
This trap is sent when a CPE XFP failure is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2192
luxNCpeXfpNotAuthorized
NOTIFICATION-TYPE
This trap is sent when an unauthorized XFP is detected in a CPE prot. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2193
luxNCpeXfpAuthorized
NOTIFICATION-TYPE
This trap is sent when an unauthorized XFP is replaced with an authorized XFP in a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2194
luxNCpeXfpRateMismatch
NOTIFICATION-TYPE
This trap is sent when a CPE XFP does not supported the user configured line rate. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2195
luxNCpeXfpRateMismatchResolved
NOTIFICATION-TYPE
This trap is sent when a CPE XFP that does not support the user configured line rate is replaced with an XFP that does. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2196
luxNOutOfFrame
NOTIFICATION-TYPE
This trap is sent when an out of frame error is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2197
luxNOutOfFrameResolved
NOTIFICATION-TYPE
This trap is sent when an out of frame error is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2198
luxNCpeLossOfFrame
NOTIFICATION-TYPE
This trap is sent when a loss of frame error is detected on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2199
luxNCpeLossOfFrameResolved
NOTIFICATION-TYPE
This trap is sent when a loss of frame error is resolved on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2200
luxNCpeOutOfFrame
NOTIFICATION-TYPE
This trap is sent when an out of frame error is detected on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2201
luxNCpeOutOfFrameResolved
NOTIFICATION-TYPE
This trap is sent when an out of frame error is resolved on a CPE port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2202
luxNCdrFailure
NOTIFICATION-TYPE
This trap is sent when a CDR failure is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2203
luxNCdrFailureResolved
NOTIFICATION-TYPE
This trap is sent when a CDR failure is resolved. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2204
luxNBitError10Em3
NOTIFICATION-TYPE
This trap is sent when the modules bit error rate exceeds 10E-3. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2205
luxNBitError10Em3Resolved
NOTIFICATION-TYPE
This trap is sent when the modules bit error rate falls below 10E-3. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2206
luxNBitError10Em4
NOTIFICATION-TYPE
This trap is sent when the modules bit error rate exceeds 10E-4. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2207
luxNBitError10Em4Resolved
NOTIFICATION-TYPE
This trap is sent when the modules bit error rate falls below 10E-4. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2208
luxNBitError10Em6
NOTIFICATION-TYPE
This trap is sent when the modules bit error rate exceeds 10E-6. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2209
luxNBitError10Em6Resolved
NOTIFICATION-TYPE
This trap is sent when the modules bit error rate falls below 10E-6. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2210
luxNBitError10Em7
NOTIFICATION-TYPE
This trap is sent when the modules bit error rate exceeds 10E-7. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2211
luxNBitError10Em7Resolved
NOTIFICATION-TYPE
This trap is sent when the modules bit error rate falls below 10E-7. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2212
luxNAisReceived
NOTIFICATION-TYPE
This trap is sent when AIS-L is received on the port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2213
luxNAisReceivedResolved
NOTIFICATION-TYPE
This trap is sent when AIS-L is no longer received on the port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2214
luxNAisTransmitted
NOTIFICATION-TYPE
This trap is sent when starts transmitting on the port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2215
luxNAisTransmittedResolved
NOTIFICATION-TYPE
This trap is sent when is no longer transmitting on the port. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2216
luxNcaseTemperatureHiTrap
NOTIFICATION-TYPE
This trap is sent when case temperature is HI. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2225
luxNcaseTemperatureNormalTrap
NOTIFICATION-TYPE
This trap is sent when case temperature is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2226
luxNcaseTemperatureLoTrap
NOTIFICATION-TYPE
This trap is sent when case temperature is LO. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2227
luxNcaseTemperatureLoNormalTrap
NOTIFICATION-TYPE
This trap is sent when case temperature is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2228
luxNpumpTemperatureHiTrap
NOTIFICATION-TYPE
This trap is sent when pump temperature is HI. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2229
luxNpumpTemperatureNormalTrap
NOTIFICATION-TYPE
This trap is sent when pump temperature is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2230
luxNcoilTemperatureHiTrap
NOTIFICATION-TYPE
This trap is sent when coil temperature is HI. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2231
luxNcoilTemperatureNormalTrap
NOTIFICATION-TYPE
This trap is sent when coil temperature is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2232
luxNlossOutputPowerTrap
NOTIFICATION-TYPE
This trap is sent when loss of output power (or gain) is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2233
luxNlossOutputPowerNormalTrap
NOTIFICATION-TYPE
This trap is sent when loss of output power (or gain) is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2234
luxNreflectedOutputPowerHiTrap
NOTIFICATION-TYPE
This trap is sent when excessive reflected output power is detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2235
luxNreflectedOutputPowerNormalTrap
NOTIFICATION-TYPE
This trap is sent when reflected output power is normal. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.2236
luxNlineRateNotSuppoted
NOTIFICATION-TYPE
This trap is sent to indicate that the module hardware does not support the configured line rate. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3001
luxNmpmBootImageChangedTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the executable image for the MPM has been changed. Upon reset of the MPM card, this new bootfile will be used. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3002
luxNdateTimeSetTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the date and time of the system has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3003
luxNuserAddedTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a new user has been added to the system. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3004
luxNuserDeletedTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a user has been deleted from the system. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3005
luxNuserPasswordChangeTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the password of one of the user's has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3006
luxNuserLevelModifiedTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the privilege level of one of the user's has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3007
luxNsystemNameChangeTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the name of the system has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3008
luxNcardAddedTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a new card has been added to the system through either CLI/SNMP in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3009
luxNcardDeletedTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a card has been deleted from the system through either CLI/SNMP in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3010
luxNmpmRedundancySwitchOverTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a mpm switchover has occurred. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3011
luxNconnectionAddedTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a connectino has been added to an ofcm/ofcd card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3012
luxNconnectionDeletedTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a connection has been deleted from an ofcm/ofcd card. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3013
luxNipAddressChangedTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the IP address has been changed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3014
luxNipNetmaskChangedTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the netmask has been changed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3015
luxNdefaultGatewayChangedTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the default gateway has been changed successfully. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3016
luxNGetCommunityChangeTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the getcommunity has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3017
luxNSetCommunityChangeTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the setcommunity has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3018
luxNModuleResetTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a module has been reset. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3019
luxNtopologyRediscoveredTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the topology database has been rediscovered which is triggered through either CLI or snmp. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3020
luxNcolorsimEnabledTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the ColorSIM feature has been enabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3021
luxNcolorsimDisabledTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the ColorSIM feature has been disabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3022
luxNautoCutoffEnabledTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the auto cutoff feature has been enabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3023
luxNautoCutoffDisabledTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the auto cutoff feature has been disabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3024
luxNextAlarmsEnabledTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the external alarm closures have been enabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3025
luxNextAlarmsDisabledTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the external alarm closures have been disabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3026
luxNdlModuleActivatedTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a module activation, switching to another module image version, has occurred. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3027
luxNhttpEnabledTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the http server has been enabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3032
luxNhttpDisabledTrap
NOTIFICATION-TYPE
This trap is sent to indicate that the http server has been disabled. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3033
luxNstaticRouteAddedTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a new route has been added to the system through either CLI/SNMP in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. The eveDescr field consists of trap description and the route information - local CC shelf, slot and destination IP address
1.3.6.1.4.1.4253.0.3034
luxNstaticRouteDeletedTrap
NOTIFICATION-TYPE
This trap is sent to indicate that a route has been deleted from the system through either CLI/SNMP in the specified source field. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. The eveDescr field consists of trap description and the route information - local CC shelf, slot and destination IP address
1.3.6.1.4.1.4253.0.3035
luxNupsrProtectionSwitchOverSrc
NOTIFICATION-TYPE
This trap is sent to indicate that UPSR protection switch over occurred on the source either through SNMP or CLI. If the module type is OCM for this trap, then after issuing this trap it goes into standby mode. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3036
luxNupsrProtectionSwitchOverDest
NOTIFICATION-TYPE
This trap is sent to indicate that UPSR protection switch over occurred on the destination either through SNMP or CLI. If the module type is OCM for this trap, then after issuing this trap it goes into active mode The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3037
luxNimnIpAddressChanged
NOTIFICATION-TYPE
This trap is sent to indicate that a IMN Ip address is successfully changed either through SNMP or CLI. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3038
luxNupsrNormal
NOTIFICATION-TYPE
This trap is sent to indicate that UPSR is successfully enabled either through SNMP or CLI on the system. This is done once UPSR functionality is normal on the system. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3039
luxNupsrDegraded
NOTIFICATION-TYPE
This trap is sent to indicate that UPSR is successfully disabled either through SNMP, CLI or SPI driver on the system. This is done after the UPSR functionality on the system is degraded The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3040
luxNusrOneAlarmAction
NOTIFICATION-TYPE
This trap is sent to indicate that user has performed acknowledgment/ unacknowledgment/Clearing of a single alarm in the alarm log either through SNMP or CLI . The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3041
luxNusrAllAlarmAction
NOTIFICATION-TYPE
This trap is sent to indicate that user has performed acknowledgment/ unacknowledgment/Clearing of all alarms in the alarm log either through SNMP or CLI . The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3042
luxNringConfigurationChanged
NOTIFICATION-TYPE
This trap is sent to indicate that the user has changed the ring configuration either through deletion or addition of ringId or pathId. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure. The eveDescr field consists of trap description and the cross connect information
1.3.6.1.4.1.4253.0.3047
luxNeventLogCleared
NOTIFICATION-TYPE
This trap is sent to indicate that the user has cleared the event log either through CLI or SNMP. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3048
luxNextAlarmInpTrap
NOTIFICATION-TYPE
This trap is sent when an user sets up alarm severity (crit/maj/minor/disable) on external alarm input. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3049
luxNextAudioAlarmTrap
NOTIFICATION-TYPE
This trap is sent when an user enables or disables audio alarm. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3050
luxNTrapHostConfigChangeTrap
NOTIFICATION-TYPE
This trap is sent when a trap host is added, deleted, or modified (port configuration). The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3051
luxNTrapHostImnRouteEnabled
NOTIFICATION-TYPE
1.3.6.1.4.1.4253.0.3052
luxNTrapHostImnRouteDisabled
NOTIFICATION-TYPE
1.3.6.1.4.1.4253.0.3053
luxNTrapHostAutoUpdateEnabled
NOTIFICATION-TYPE
1.3.6.1.4.1.4253.0.3054
luxNTrapHostAutoUpdateDisabled
NOTIFICATION-TYPE
1.3.6.1.4.1.4253.0.3055
luxNTrapPathAdded
NOTIFICATION-TYPE
This trap is sent when a path is configured. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3056
luxNTrapPathDeleted
NOTIFICATION-TYPE
This trap is sent when a path is deleted. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply, fan and ext. alarm input, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3057
luxNdlModuleActivateFailedTrap
NOTIFICATION-TYPE
This trap is sent when a module activation, switching to another module image version, has failed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3058
luxNLogServerAddedTrap
NOTIFICATION-TYPE
This trap is sent when a syslog server has been added. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3059
luxNLogServerDeletedTrap
NOTIFICATION-TYPE
This trap is sent when a syslog server has been deleted. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3060
luxNLogMaskChangedTrap
NOTIFICATION-TYPE
This trap is sent when the syslog mask has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3061
luxNRadiusAuthChangedTrap
NOTIFICATION-TYPE
This trap is sent when the radius authentication order has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3062
luxNRadiusDefaultRealmChangedTrap
NOTIFICATION-TYPE
This trap is sent when the radius default realm has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3063
luxNRadiusNasIdChangedTrap
NOTIFICATION-TYPE
This trap is sent when the radius NAS Identifier has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3064
luxNRadiusRetriesChangedTrap
NOTIFICATION-TYPE
This trap is sent when the radius retries has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3065
luxNRadiusServerAddedTrap
NOTIFICATION-TYPE
This trap is sent when a radius server has been added. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3066
luxNRadiusServerDeletedTrap
NOTIFICATION-TYPE
This trap is sent when radius server has been deleted. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3067
luxNRadiusServerModifiedTrap
NOTIFICATION-TYPE
This trap is sent when radius server port or secret has been modified. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3068
luxNRadiusTimeoutChangedTrap
NOTIFICATION-TYPE
This trap is sent when the radius timeout has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3069
luxNSshEnabledTrap
NOTIFICATION-TYPE
This trap is sent when the SSHD has been enabled. The source is a 4 or 5 tuple specifying the type location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3070
luxNSshDisabledTrap
NOTIFICATION-TYPE
This trap is sent when the SSHD has been disabled. The source is a 4 or 5 tuple specifying the type location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3071
luxNSshKeySizeSetTrap
NOTIFICATION-TYPE
This trap is sent when the SSHD key size has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3072
luxNSshMaxSessionsSetTrap
NOTIFICATION-TYPE
This trap is sent when the telnet/SSHD max sessions has been changed. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3073
luxNSshKeyGeneratedTrap
NOTIFICATION-TYPE
This trap is sent when the SSH DSS key has finished being generated. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.3074
luxNlogonIntruderTrap
NOTIFICATION-TYPE
This trap is sent to indicate that someone is repeatly trying to logon using an invalid password. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.4000
luxNlogonSessionStarted
NOTIFICATION-TYPE
This trap is sent to indicate that a user has logged into the MPM. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.4001
luxNlogonSessionClosed
NOTIFICATION-TYPE
This trap is sent to indicate that a user has logged out of the MPM. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.4002
luxNcpAuthenticationErrorTrap
NOTIFICATION-TYPE
This trap is sent to indicate that an invalid login attempt has been detected. The source is a 4 or 5 tuple specifying the type, location, shelf, slot ID, and optionally the port number of the source of the event. In the case of the power supply and fan, the shelf number is set to 0. Each event has an unique event ID. It also has a preset event severity. The severity or trap type may be: critical, major, minor, or normal. For a given event severity, there is a corresponding system status, not necessarily the same as the event severity. For each reported trap, the IP address of the CP responsible for sending this trap is also included in the trap structure.
1.3.6.1.4.1.4253.0.4003