LSI-megaRAID-SAS-IR-MIB
- Registered at
- 1.3.6.1.4.1.3582
- Namespace
- lsi
- Source file
LSI-megaRAID-SAS-IR-MIB- Digest
sha256:8262deeec5ddc9648721ff0948d5ef75ab9e6f9abf05ec036fdbdd90df8714b9
Imports
| From | Symbols |
|---|---|
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | Counter32, Gauge32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso |
| SNMPv2-TC | DisplayString, PhysAddress, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
LSI-megaRAID-SAS-IR-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| lsi OBJECT-IDENTITY | 1.3.6.1.4.1.3582 | |||
| lsiStorageComponents OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5 | |||
| lsiRAIDServer OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1 | |||
| hostName OBJECT-TYPE Name of the host system. | 1.3.6.1.4.1.3582.5.1.1 | DisplayString (SIZE(0..63)) | read-only | mandatory |
| hostOSInfo OBJECT-TYPE Operating System description where SNMP agent is running. | 1.3.6.1.4.1.3582.5.1.2 | DisplayString (SIZE(0..63)) | read-only | mandatory |
| versionInfo OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.3 | |||
| mibVersion OBJECT-TYPE The MIB version no. (xx.yy.zz) | 1.3.6.1.4.1.3582.5.1.3.1 | DisplayString (SIZE(0..63)) | read-only | mandatory |
| agentModuleName OBJECT-TYPE The agent module name | 1.3.6.1.4.1.3582.5.1.3.2 | DisplayString (SIZE(0..63)) | read-only | mandatory |
| agentModuleVersion OBJECT-TYPE The module version in xx.yy format. Where xx is the major version number and yy is the minor version number(without build information). | 1.3.6.1.4.1.3582.5.1.3.3 | DisplayString (SIZE(0..63)) | read-only | mandatory |
| releaseDate OBJECT-TYPE Module Release Date (DD/MM/YYYY) | 1.3.6.1.4.1.3582.5.1.3.4 | DisplayString (SIZE(0..63)) | read-only | mandatory |
| megaRAID_SAS_IR OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4 | |||
| adapter OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.1 | |||
| adapterDetails OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.1.1 | |||
| adpNumber OBJECT-TYPE The total no of SAS adapters present. | 1.3.6.1.4.1.3582.5.1.4.1.1.1 | Gauge | read-only | mandatory |
| adapterPropertiesTable OBJECT-TYPE A List of adapter Entries containing Information/Properties about the adapters. | 1.3.6.1.4.1.3582.5.1.4.1.1.2 | not-accessible | optional | |
| adapterPropertiesEntry OBJECT-TYPE An Entry in the adapter table. | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1 | not-accessible | mandatory | |
| adapterID OBJECT-TYPE AdapterID for this Adapter.(Unique) | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.1 | INTEGER | read-only | optional |
| rebuildRate OBJECT-TYPE Rebuild rate on this Adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.2 | INTEGER | read-only | optional |
| reconstructionRate OBJECT-TYPE Reconstruction rate on this Adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.3 | INTEGER | read-only | optional |
| alarmState OBJECT-TYPE Alarm is enabled(1) or disabled(0) on this adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.4 | INTEGER | read-only | optional |
| cacheFlushInterval OBJECT-TYPE Cache flush interval in seconds for this adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.5 | INTEGER | read-only | optional |
| clusterState OBJECT-TYPE Cluster is enabled(1) or disabled(0) on this adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.6 | INTEGER | read-only | optional |
| predFailPollInterval OBJECT-TYPE Number of seconds between predictive fail polls on this adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.7 | INTEGER | read-only | optional |
| intThrottleCount OBJECT-TYPE Interrupt throttle active count on this adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.8 | INTEGER | read-only | optional |
| intThrottleTimeUs OBJECT-TYPE Interrupt throttle completion hold time on this adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.9 | INTEGER | read-only | optional |
| patrolReadRate OBJECT-TYPE Patrol Read Rate for this adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.10 | INTEGER | read-only | optional |
| bgiRate OBJECT-TYPE Background initialization rate for this adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.11 | INTEGER | read-only | optional |
| ccRate OBJECT-TYPE Consistency Check rate on this Adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.12 | INTEGER | read-only | optional |
| spinupDelay OBJECT-TYPE Number of seconds to delay among spinup groups for this adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.13 | INTEGER | read-only | optional |
| spinupDriveCount OBJECT-TYPE Maximum number of drives to spin up at one time for this adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.14 | INTEGER | read-only | optional |
| coercionMode OBJECT-TYPE Drive capacity coercion mode. 0->None; 1->128MB; 2->1GB; 3->Adaptive Coercion. | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.15 | INTEGER | read-only | optional |
| disableAutoRebuild OBJECT-TYPE auto-rebuild and hot-spare commissioning status. 1->Disable , 0->Enable | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.16 | INTEGER | read-only | optional |
| disableBatteryWarning OBJECT-TYPE disable/enable warnings for missing battery or missing HW status. 1->Disable , 0->Enable | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.17 | INTEGER | read-only | optional |
| multipathSupport OBJECT-TYPE Multipath is supported or not supported on this adapter.Values: not supported(0),supported(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.18 | INTEGER | read-only | optional |
| ssdSMARTerEnabled OBJECT-TYPE Copyback to SSD on SMART error. Values Enabled(0),Disabled(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.19 | INTEGER | read-only | optional |
| sasAddr OBJECT-TYPE This field gives the controller SAS address | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.20 | DisplayString | read-only | optional |
| auxilaryPowerPresent OBJECT-TYPE Presence of Auxilary Power | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.21 | DisplayString | read-only | optional |
| ddLifeCurveStatus OBJECT-TYPE Check for throttling | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.22 | DisplayString | read-only | optional |
| ddSSDLifeLeft OBJECT-TYPE Percentage of SSD life left | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.23 | DisplayString | read-only | optional |
| dDStatus OBJECT-TYPE Overall DD status | 1.3.6.1.4.1.3582.5.1.4.1.1.2.1.24 | DisplayString | read-only | optional |
| adapterInfoTable OBJECT-TYPE A List of adapter Entries containing Information/Properties about the adapters. | 1.3.6.1.4.1.3582.5.1.4.1.1.3 | not-accessible | optional | |
| adapterInfoEntry OBJECT-TYPE An Entry in the adapterInfo table. | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1 | not-accessible | mandatory | |
| infAdpID OBJECT-TYPE AdapterID for this Adapter.(Unique) | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.1 | INTEGER | read-only | optional |
| vendorId OBJECT-TYPE PCI Vendor ID for this Adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.2 | INTEGER | read-only | optional |
| devId OBJECT-TYPE PCI Device ID for this Adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.3 | INTEGER | read-only | optional |
| subVendorID OBJECT-TYPE PCI Sub-Vendor ID for this adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.4 | INTEGER | read-only | optional |
| subDevID OBJECT-TYPE PCI Sub-Device ID for this adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.5 | INTEGER | read-only | optional |
| hostInterface OBJECT-TYPE Host interface information for this adapter. Values are as follows: N/A(0), PCIX(1), PCIE(2), iSCSI(3), SAS_3G(4) | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.6 | INTEGER | read-only | optional |
| hostInterfacePortCnt OBJECT-TYPE Port Count on this adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.7 | INTEGER | read-only | optional |
| hostInterfacePortAddr OBJECT-TYPE Port address comma delimited | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.8 | DisplayString | read-only | optional |
| devInterface OBJECT-TYPE Multiple device interface support values separated by space. | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.9 | DisplayString | read-only | optional |
| devInterfacePortCnt OBJECT-TYPE Device Port Count on this adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.10 | INTEGER | read-only | optional |
| devInterfacePortAddr OBJECT-TYPE Device Port address comma delimited | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.11 | DisplayString | read-only | optional |
| productName OBJECT-TYPE Product name e.g. SAS2008 B1. | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.12 | DisplayString | read-only | optional |
| serialNo OBJECT-TYPE Controller serial number | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.13 | DisplayString | read-only | optional |
| firmwareVersion OBJECT-TYPE Firmware version Format->(Firmware Package Version:Version:Date:Time) | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.14 | DisplayString | read-only | optional |
| driverVersion OBJECT-TYPE Driver version Format->(Driver Name:Version) | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.15 | DisplayString | read-only | optional |
| nvramSize OBJECT-TYPE NVRAM size in KB for this adapter.A value -1 for invalid or undefined size. | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.16 | INTEGER | read-only | optional |
| memorySize OBJECT-TYPE Memory size in MB for this adapter.A value -1 for invalid or undefined size. | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.17 | INTEGER | read-only | optional |
| flashSize OBJECT-TYPE Flash size in MB for this adapter.A value -1 for invalid or undefined size. | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.18 | INTEGER | read-only | optional |
| vdPresentCount OBJECT-TYPE Virtual devices present in this adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.19 | INTEGER | read-only | optional |
| vdDegradedCount OBJECT-TYPE Number of virtual devices in this adapter that are critical | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.20 | INTEGER | read-only | optional |
| vdOfflineCount OBJECT-TYPE Number of virtual devices in this adapter that are offline | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.21 | INTEGER | read-only | optional |
| pdPresentCount OBJECT-TYPE Physical devices present in this adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.22 | INTEGER | read-only | optional |
| pdDiskPresentCount OBJECT-TYPE Physical disk devices present in this adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.23 | INTEGER | read-only | optional |
| pdDiskPredFailureCount OBJECT-TYPE Number of disk devices in this adapter that are critical | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.24 | INTEGER | read-only | optional |
| pdDiskFailedCount OBJECT-TYPE Number of disk devices in this adapter that are failed | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.25 | INTEGER | read-only | optional |
| clusterStatus OBJECT-TYPE Cluster state on this adapter. Values: ACTIVE(1), INACTIVE(0) | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.26 | INTEGER | read-only | optional |
| devInterfaceType OBJECT-TYPE Type of the interface of the IR adapter. Values: GEN1(0), GEN2(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.3.1.27 | INTEGER | read-only | optional |
| adapterSupportInfoTable OBJECT-TYPE A List of Entries containing Properties supported by the Controller. | 1.3.6.1.4.1.3582.5.1.4.1.1.4 | not-accessible | optional | |
| adapterSupportInfoEntry OBJECT-TYPE An Entry in the adapter table. | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1 | not-accessible | mandatory | |
| suAdpID OBJECT-TYPE AdapterID for this Adapter.(Unique) | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.1 | INTEGER | read-only | optional |
| supportMaxArms OBJECT-TYPE Maximum arms per Logical Drive supported for this Adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.2 | INTEGER | read-only | optional |
| supportMaxSpans OBJECT-TYPE Maximum spans per Logical Drive supported for this Adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.3 | INTEGER | read-only | optional |
| supportMaxArrays OBJECT-TYPE Maximum number arrays supported this Adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.4 | INTEGER | read-only | optional |
| supportMaxLDs OBJECT-TYPE Maximum number of Logical Drive's supported for this Adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.5 | INTEGER | read-only | optional |
| supportHardwarePresent OBJECT-TYPE Supported Hardware on this adapter. bbu(1),alarm(2),nvram(3),uart(4). For multiple hardware support a comma delimited list will appear. | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.6 | DisplayString | read-only | optional |
| supportMaxConcurrentCmds OBJECT-TYPE The maximum parallel commands supported on this Adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.7 | INTEGER | read-only | optional |
| supportMaxSGECount OBJECT-TYPE The maximum Scatter Gather Element count allowed on this Adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.8 | INTEGER | read-only | optional |
| supportMaxRequestSize OBJECT-TYPE The maximum data transfer size in sectors, on this Adapter. | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.9 | INTEGER | read-only | optional |
| supportClusterPermitted OBJECT-TYPE Clustering support on this Adapter. Values: FALSE(0), TRUE(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.10 | INTEGER | read-only | optional |
| supportMinStripeSize OBJECT-TYPE Minimum stripe size supported. 0(512),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.11 | INTEGER | read-only | mandatory |
| supportMaxStripeSize OBJECT-TYPE Maximum stripe size supported. 0(512),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.12 | INTEGER | read-only | mandatory |
| supportSupportsSAS OBJECT-TYPE SAS physical drive support.Values: notSupported(0), supported(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.13 | INTEGER | read-only | mandatory |
| supportSupportsSATA OBJECT-TYPE SATA physical drive support.Values: notSupported(0), supported(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.14 | INTEGER | read-only | mandatory |
| supportAllowMixInEnclosure OBJECT-TYPE Mix InEnclosure support.Values: notSupported(0), supported(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.15 | INTEGER | read-only | mandatory |
| supportAllowMixInVD OBJECT-TYPE MixInVD support.Values: notSupported(0), supported(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.16 | INTEGER | read-only | mandatory |
| supportAllowSataInCluster OBJECT-TYPE SataInCluster support. Values: notSupported(0), supported(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.17 | INTEGER | read-only | mandatory |
| allowSSDMixInLD OBJECT-TYPE allow SAS/SATA SSD mix within an LD. allow(1), not allow(0) | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.18 | INTEGER | read-only | mandatory |
| allowMixSSDHDDInLD OBJECT-TYPE allow SSD/HDD mix within an LD.allow(1), not allow(0) | 1.3.6.1.4.1.3582.5.1.4.1.1.4.1.19 | INTEGER | read-only | mandatory |
| adpOperationsSupportInfoTable OBJECT-TYPE A List of Entries containing operations supported by the Controller. | 1.3.6.1.4.1.3582.5.1.4.1.1.5 | not-accessible | optional | |
| adpOperationsSupportInfoEntry OBJECT-TYPE An Entry in the adapter table. | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1 | not-accessible | mandatory | |
| opAdpID OBJECT-TYPE AdapterID for this Adapter.(Unique) | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.1 | INTEGER | read-only | optional |
| rbldRate OBJECT-TYPE Rebuilding rate change support for this Adapter. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.2 | INTEGER | read-only | optional |
| suCCRate OBJECT-TYPE Consistency Check rate change support for this Adapter. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.3 | INTEGER | read-only | optional |
| suBgiRate OBJECT-TYPE Background initialization rate change support for this adapter. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.4 | INTEGER | read-only | optional |
| reconRate OBJECT-TYPE Reconstruction rate change support for this adapter. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.5 | INTEGER | read-only | optional |
| patrolRate OBJECT-TYPE Patrol read rate change support for this adapter. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.6 | INTEGER | read-only | optional |
| alarmControl OBJECT-TYPE Alarm control support for this adapter. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.7 | INTEGER | read-only | optional |
| clusterSupported OBJECT-TYPE Cluster support for this adapter. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.8 | INTEGER | read-only | optional |
| bbu OBJECT-TYPE BBU support for this adapter. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.9 | INTEGER | read-only | optional |
| spanningAllowed OBJECT-TYPE Spanning support for this adapter. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.10 | INTEGER | read-only | optional |
| dedicatedHotSpares OBJECT-TYPE Dedicated HotSpares for this adapter. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.11 | INTEGER | read-only | optional |
| revertibleHotSpares OBJECT-TYPE Revertible HotSpares support for this adapter. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.12 | INTEGER | read-only | optional |
| foreignConfigImport OBJECT-TYPE Support foreign config import on this adapter. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.13 | INTEGER | read-only | optional |
| selfDiagnostic OBJECT-TYPE Controller supports self diagnostic. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.14 | INTEGER | read-only | optional |
| allowMixedRedundancyOnArray OBJECT-TYPE Allow different Virtual Disk on the same array to have different redundancy levels Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.15 | INTEGER | read-only | optional |
| globalHotSpares OBJECT-TYPE Global hot spares are supported. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.16 | INTEGER | read-only | optional |
| oceWithNoDriveAddition OBJECT-TYPE Online Capacity Expansion supported. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.5.1.17 | INTEGER | read-only | optional |
| driveOperationSupportTable OBJECT-TYPE A List of operations supported by Physical Drive. | 1.3.6.1.4.1.3582.5.1.4.1.1.6 | not-accessible | optional | |
| driveOperationSupportEntry OBJECT-TYPE An Entry in the driveOperationSupport table. | 1.3.6.1.4.1.3582.5.1.4.1.1.6.1 | not-accessible | mandatory | |
| drvAdpID OBJECT-TYPE Unique adapter ID | 1.3.6.1.4.1.3582.5.1.4.1.1.6.1.1 | INTEGER | read-only | mandatory |
| forceOnline OBJECT-TYPE Physical Drive force Online operation support Values: notSupported(0), supported(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.6.1.2 | INTEGER | read-only | mandatory |
| forceOffline OBJECT-TYPE Physical Drive force Offline operation support Values: notSupported(0), supported(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.6.1.3 | INTEGER | read-only | mandatory |
| forceRebuild OBJECT-TYPE Physical Drive force Rebuild operation support Values: notSupported(0), supported(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.6.1.4 | INTEGER | read-only | mandatory |
| vdOperationSupportTable OBJECT-TYPE A List operations supported by Virtual Drive | 1.3.6.1.4.1.3582.5.1.4.1.1.7 | not-accessible | optional | |
| vdOperationSupportEntry OBJECT-TYPE An Entry in the vdOperationSupport Table. | 1.3.6.1.4.1.3582.5.1.4.1.1.7.1 | not-accessible | mandatory | |
| vdOpAdpID OBJECT-TYPE Unique adapter ID | 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.1 | INTEGER | read-only | mandatory |
| readPolicy OBJECT-TYPE Read policy support. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.2 | INTEGER | read-only | mandatory |
| writePolicy OBJECT-TYPE Write policy support. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.3 | INTEGER | read-only | mandatory |
| ioPolicy OBJECT-TYPE IO policy support. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.4 | INTEGER | read-only | mandatory |
| accessPolicy OBJECT-TYPE Access policy support. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.5 | INTEGER | read-only | mandatory |
| diskCachePolicy OBJECT-TYPE Disk Cache Policy support. Values: False(0), True(1) | 1.3.6.1.4.1.3582.5.1.4.1.1.7.1.6 | INTEGER | read-only | mandatory |
| bbuInfo OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.1.2 | |||
| bbuNumber OBJECT-TYPE The present number of rows in the bbuTable. | 1.3.6.1.4.1.3582.5.1.4.1.2.1 | Gauge | read-only | mandatory |
| bbuTable OBJECT-TYPE A List of bbu Entries containing Information/Properties about the BBU. | 1.3.6.1.4.1.3582.5.1.4.1.2.2 | not-accessible | optional | |
| bbuEntry OBJECT-TYPE An Entry in the BBU table. | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1 | not-accessible | mandatory | |
| bbuID OBJECT-TYPE BBUID for this BBU.(Unique) | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.1 | INTEGER | read-only | optional |
| batteryType OBJECT-TYPE BBU Type: Values: n/a(0), ibbu(1), bbu(2), zcr_legacy(3), itbbu3(4) | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.2 | INTEGER | read-only | optional |
| nextLearnTime OBJECT-TYPE Time of next scheduled lean cycle (seconds path 1/1/2000) | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.3 | INTEGER | read-only | optional |
| absStateOfCharge OBJECT-TYPE Predicted remaining capacity expressed as % of DesignCapacity() (0-100). Value of -1 means not supported | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.4 | INTEGER (0..100) | read-only | optional |
| fullChargeCapacity OBJECT-TYPE Predicted pack capacity when it is fully charged in mAh | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.5 | INTEGER | read-only | optional |
| averageEmptyTime OBJECT-TYPE One-minute rolling average of the predicted remaining battery life. Value of -1 means not supported | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.6 | INTEGER | read-only | optional |
| cycleCount OBJECT-TYPE Number of charge cycles the battery has experienced. Value of -1 means not supported | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.7 | INTEGER | read-only | optional |
| firmwareStatus OBJECT-TYPE condition of battery in following order: packMissing(0/1) voltageLow(0/1) temperatureHigh(0/1) chargeActive(0/1) dischargeActive(0/1) learnCycleRequested(0/1) learnCycleActive(0/1) learnCycleFailed(0/1) learnCycleTimeout(0/1) i2cErrorsDetected(0/1) Only enabled(1) values will be shown | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.8 | DisplayString | read-only | optional |
| voltage OBJECT-TYPE Accurate battery terminal voltage in mV, resolution of 1mV | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.9 | INTEGER | read-only | optional |
| autoLearnPeriod OBJECT-TYPE Time (in seconds) between learn cycles (0 to disable auto learn) | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.10 | INTEGER | read-only | optional |
| relStateOfCharge OBJECT-TYPE Predicted remaining capacity expressed as % of FullChargeCapacity() (0-100). Value of -1 means not supported | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.11 | INTEGER (0..100) | read-only | optional |
| capacityRemain OBJECT-TYPE Predicted charge or energy remaining in the battery in mAh | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.12 | INTEGER | read-only | optional |
| runTimeToEmpty OBJECT-TYPE (in minutes)Relative gain or loss in remaining life in response to change in power policy. Value of -1 means not supported | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.13 | INTEGER | read-only | optional |
| avgTimeToFull OBJECT-TYPE One-minute rolling average of predicted remaining time to full charge. Value of -1 means not supported | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.14 | INTEGER | read-only | optional |
| errorMargin OBJECT-TYPE Expected margin of error (%) in charge calculation (2-100). Value of -1 means not supported | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.15 | INTEGER (2..100) | read-only | optional |
| temperature OBJECT-TYPE Battery temperature in degree Centigrade | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.16 | INTEGER | read-only | optional |
| mfgName OBJECT-TYPE Battery manufacturer's name | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.17 | DisplayString | read-only | optional |
| deviceName OBJECT-TYPE Battery name | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.18 | DisplayString | read-only | optional |
| serialNumber OBJECT-TYPE Battery serialNumber | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.19 | DisplayString | read-only | optional |
| chargerStatus OBJECT-TYPE Battery charger status. Values: N/A(-1), off(0), complete(1), progress(2) | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.20 | INTEGER | read-only | optional |
| adpID OBJECT-TYPE The adapter id where BBU is attached | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.21 | INTEGER | read-only | optional |
| remainingCapAlarm OBJECT-TYPE Remaining capacity to alarm. Value of -1 means not supported | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.22 | INTEGER | read-only | optional |
| remainingTimeAlarm OBJECT-TYPE Remaining time to alarm. Value of -1 means not supported | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.23 | INTEGER | read-only | optional |
| bbu_current OBJECT-TYPE Current(In mA) being supplied (or accepted) through the terminals of the battery | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.24 | INTEGER | read-only | optional |
| gasGaugeStatus OBJECT-TYPE Gas guage status | 1.3.6.1.4.1.3582.5.1.4.1.2.2.1.25 | INTEGER | read-only | optional |
| device OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.2 | |||
| physicalDriveInfo OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.2.1 | |||
| pdNumber OBJECT-TYPE The present number of rows in the physicalDrive table. | 1.3.6.1.4.1.3582.5.1.4.2.1.1 | Gauge | read-only | mandatory |
| pdTable OBJECT-TYPE A List of physicalDrive Entries containing Information/Properties about the drives | 1.3.6.1.4.1.3582.5.1.4.2.1.2 | not-accessible | optional | |
| pdEntry OBJECT-TYPE An Entry in the Device Table. | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1 | not-accessible | optional | |
| pdIndex OBJECT-TYPE The unique ID | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.1 | INTEGER | read-only | optional |
| physDevID OBJECT-TYPE The Device ID | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.2 | INTEGER | read-only | optional |
| oemSupported OBJECT-TYPE Drive support by the OEM (OEM-specific checks) Values: notSupported(1), supported(0) | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.3 | INTEGER | read-only | optional |
| scsiDevType OBJECT-TYPE Type of this Device. Values: disk(0), tape(1), printer(2), processor(3), cdrom(5), scanner(6), optical(7), enclosure(13), dvd(10), unknown(31) | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.4 | INTEGER | read-only | optional |
| connectedAdapterPort OBJECT-TYPE Adapter port to which the device is connected. | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.5 | INTEGER | read-only | optional |
| deviceSpeed OBJECT-TYPE Maximum supported speed. Values: speed_unknown(0), speed_1p5G(1), speed_3G(2),speed_6G(3) | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.6 | INTEGER | read-only | optional |
| mediaErrCount OBJECT-TYPE Error count of the device | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.7 | INTEGER | read-only | optional |
| otherErrCount OBJECT-TYPE other error count of the device | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.8 | INTEGER | read-only | optional |
| predFailCount OBJECT-TYPE Predictive fail count of the device | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.9 | INTEGER | read-only | optional |
| pdState OBJECT-TYPE Firmware's interpretation of drive state. Values: unconfigured_good(0), unconfigured_bad(1), hot_spare(2), offline(16), failed(17), rebuild(20), online(24),copyback(32),system(64) | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.10 | INTEGER | read-only | optional |
| disabledForRemoval OBJECT-TYPE If true, drive is ready for removal. Values: false(0), true(1) | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.11 | INTEGER | read-only | optional |
| linkSpeed OBJECT-TYPE Negotiated link speed. Values: speed_unknown(0), speed_1p5G(1), speed_3G(2), speed_6G(3) | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.12 | INTEGER | read-only | optional |
| pdSupportFlags OBJECT-TYPE 1st Byte:forcedPDGUID(0/1),2nd Byte:inVD(0/1),3rd Byte:isGlobalSpare(0/1),4th Byte:isSpare(0/1),5th Byte:isForeign(0/1),6th Byte:intf(0-Unknown, 1-parallel SCSI, 2-SAS, 3-SATA, 4-FC).A comma delimited list will appear. | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.13 | DisplayString | read-only | optional |
| pdSasAddr OBJECT-TYPE Device SAS addresses. Comma separeted for multiple address | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.14 | DisplayString | read-only | optional |
| rawSize OBJECT-TYPE Size(MB) before COD and coercion | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.15 | INTEGER | read-only | optional |
| nonCoercedSize OBJECT-TYPE Size(MB) after COD is reserved but before coercion | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.16 | INTEGER | read-only | optional |
| coercedSize OBJECT-TYPE Size(MB) after COD is reserved and after coercion | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.17 | INTEGER | read-only | optional |
| enclDeviceId OBJECT-TYPE Enclosure's device Id (in decimal); if device is not within enclosure value is -1 | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.18 | INTEGER | read-only | optional |
| enclIndex OBJECT-TYPE Firmware internal enclosure index | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.19 | INTEGER | read-only | optional |
| slotNumber OBJECT-TYPE Slot number of this drive, if this Physical Drive is an enclosure then -1 | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.20 | INTEGER (0..255) | read-only | optional |
| pdOperationProgress OBJECT-TYPE % Progress is %. e.g. Rebuild progress is 10% | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.21 | DisplayString | read-only | optional |
| pdAdpID OBJECT-TYPE Controller id where this Physical Drive is attached | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.22 | INTEGER | read-only | optional |
| operationSupport OBJECT-TYPE Online,Offline,Failed,Bad,Uncofigured good,Unconfigured bad, Spare,Spare,replaceMissing,markMissing,startRebuild,stopRebuild, locate,stopSecureEraseNonSED,FWDownloadAllowed | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.23 | DisplayString | read-only | optional |
| vendorID OBJECT-TYPE Vendor ID | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.24 | DisplayString | read-only | optional |
| productID OBJECT-TYPE Product ID | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.25 | DisplayString | read-only | optional |
| pdFwversion OBJECT-TYPE Physical drive firmware version | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.26 | DisplayString | read-only | optional |
| pdSerialNumber OBJECT-TYPE Physical drive serial number | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.27 | DisplayString | read-only | optional |
| diskType OBJECT-TYPE Type of the disk : 0-Unknown, 1-parallel SCSI, 2-SAS, 3-SATA, 4-FC | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.28 | INTEGER | read-only | optional |
| partnerDevId OBJECT-TYPE If drive is in an enclosure with dual paths,This is Partner Device ID. In all other cases INVALID(-1) | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.29 | INTEGER | read-only | optional |
| mediatype OBJECT-TYPE Media Type HDD(0),SSD(1) | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.30 | INTEGER | read-only | optional |
| oemCertified OBJECT-TYPE Indicates whether device is certified(0) or not(1) | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.31 | INTEGER | read-only | optional |
| pdTemperature OBJECT-TYPE Physical Drive temperature in Celsius | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.32 | INTEGER | read-only | optional |
| piType OBJECT-TYPE SAS Protection Information Type .No SAS protection type used(0) ,SAS PI Type 1(1) ,SAS PI Type 2(2) ,SAS PI Type 3(3) ,Reserved SAS PI Type 4(4) ,Reserved SAS PI Type 5(5) ,Reserved SAS PI Type 6(6) ,Reserved SAS PI Type 7(7). | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.33 | INTEGER | read-only | optional |
| userDataBlockSize OBJECT-TYPE Number of bytes of user data in LBA | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.34 | INTEGER | read-only | optional |
| cage OBJECT-TYPE Current Cage that holds the SSD | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.35 | INTEGER | read-only | optional |
| location OBJECT-TYPE Current location of SSD 0 - Upper, 1 - Lower | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.36 | DisplayString | read-only | optional |
| whtemperature OBJECT-TYPE Temperature of each SSD | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.37 | INTEGER | read-only | optional |
| flashType OBJECT-TYPE Flash Type being used (SLC / MLC / EMLC) | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.38 | DisplayString | read-only | optional |
| lifeCurveStatus OBJECT-TYPE 100 - No throttling being done, 90 - SSD is being throttled | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.39 | DisplayString | read-only | optional |
| sSDLifeLeft OBJECT-TYPE Percentage of SSD life left | 1.3.6.1.4.1.3582.5.1.4.2.1.2.1.40 | DisplayString | read-only | optional |
| virtualDevice OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.3 | |||
| vdInfo OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.3.1 | |||
| vdNumber OBJECT-TYPE The present number of rows in the virtualDrive table. | 1.3.6.1.4.1.3582.5.1.4.3.1.1 | Gauge | read-only | mandatory |
| vdTable OBJECT-TYPE A List of Virtual Drive Entries containing Information/Properties about the virtualDrive. | 1.3.6.1.4.1.3582.5.1.4.3.1.2 | not-accessible | optional | |
| vdEntry OBJECT-TYPE An Entry in the virtualDrive Table. | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1 | not-accessible | optional | |
| virtualDevID OBJECT-TYPE The unique Virtual Drive ID | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.1 | INTEGER | read-only | optional |
| size OBJECT-TYPE Total size in MB of the drive | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.2 | INTEGER | read-only | optional |
| clusterOwnerDeviceId OBJECT-TYPE Virtual Drive owner's device Id | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.3 | INTEGER | read-only | optional |
| targetId OBJECT-TYPE Virtual Drive target id (i.e. 0 to 63) | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.4 | INTEGER | read-only | optional |
| state OBJECT-TYPE Virtual Drive state. Values: offline(0), partially_degraded(1), degraded(2), optimal(3) | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.5 | INTEGER | read-only | optional |
| name OBJECT-TYPE Virtual Drive name | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.6 | DisplayString | read-only | optional |
| defaultCachePolicy OBJECT-TYPE Default cache policy settings. Values: direct_io(0), cached_io(1) | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.7 | INTEGER | read-only | optional |
| vdAccessPolicy OBJECT-TYPE Access policy settings. Values: access_rw(0), access_read_only(2), access_blocked(3) | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.8 | INTEGER | read-only | optional |
| vdDiskCachePolicy OBJECT-TYPE Physical disk cache policy. Values: enable(1), disable(2) | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.9 | INTEGER (1..2) | read-write | optional |
| bgiState OBJECT-TYPE BGI state on this VD. Values disable(1), enable(0) | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.10 | INTEGER | read-only | optional |
| prl OBJECT-TYPE Primay raid level. Values: 0(RAID-0), 1(RAID-1), 3(RAID-3), 4(RAID-4), 5(RAID-5), 6(RAID-6),15(Single Disk or JBOD), 17(RAID-1E/10), 21(RAID-5E), 31(Concatenation),37(RAID-5EEE) | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.11 | INTEGER | read-only | optional |
| rLQ OBJECT-TYPE Raid level qualifier | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.12 | INTEGER | read-only | optional |
| sRL OBJECT-TYPE Secondary raid level. Values: 0(Stripped), 1(Mirrored), 2(Concatenated), 3(Spanned), -1(Not Supported for IR2) | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.13 | INTEGER | read-only | optional |
| stripeSize OBJECT-TYPE Stripe Size. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.14 | INTEGER | read-only | optional |
| numDrives OBJECT-TYPE Number of drivers per span | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.15 | INTEGER | read-only | optional |
| spanDepth OBJECT-TYPE Number of spans. If only one array then it is considered as 1 span | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.16 | INTEGER | read-only | optional |
| initState OBJECT-TYPE 0=no init, 1=quick init, 2=full init | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.17 | INTEGER | read-only | optional |
| currentCachePolicy OBJECT-TYPE Default cache policy settings. Values: direct_io(0), cached_io(1) | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.18 | INTEGER | read-only | optional |
| operationProgress OBJECT-TYPE Progress % for operation x/ No operation in progress | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.19 | DisplayString | read-only | optional |
| vdAdpID OBJECT-TYPE Controller id where this vd is present | 1.3.6.1.4.1.3582.5.1.4.3.1.2.1.20 | INTEGER | read-only | optional |
| vdSpanInfo OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.3.2 | |||
| vdSpanNumber OBJECT-TYPE The present number of rows in the virtualDrive table. | 1.3.6.1.4.1.3582.5.1.4.3.2.1 | Gauge | read-only | mandatory |
| vdSpanTable OBJECT-TYPE A List of span Entries containing Information/Properties vd span. | 1.3.6.1.4.1.3582.5.1.4.3.2.2 | not-accessible | optional | |
| vdSpanEntry OBJECT-TYPE An Entry in the vdSpan Table. | 1.3.6.1.4.1.3582.5.1.4.3.2.2.1 | not-accessible | optional | |
| spanID OBJECT-TYPE The unique Span ID | 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.1 | INTEGER | read-only | optional |
| vDevID OBJECT-TYPE The Virtual Device ID | 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.2 | INTEGER | read-only | optional |
| startBlock OBJECT-TYPE Span physical disk starting block | 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.3 | INTEGER | read-only | optional |
| numBlocks OBJECT-TYPE Span physical disk block count | 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.4 | DisplayString | read-only | optional |
| vdsArrayRef OBJECT-TYPE Array reference (index) | 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.5 | INTEGER | read-only | optional |
| spAdpId OBJECT-TYPE Adapter where the span will be found | 1.3.6.1.4.1.3582.5.1.4.3.2.2.1.6 | INTEGER | read-only | optional |
| arrayInfo OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.3.3 | |||
| arrayNumber OBJECT-TYPE The present number of rows in the array table. | 1.3.6.1.4.1.3582.5.1.4.3.3.1 | Gauge | read-only | mandatory |
| arrayTable OBJECT-TYPE A List of array Entries containing Information/Properties about the arrays. | 1.3.6.1.4.1.3582.5.1.4.3.3.2 | not-accessible | optional | |
| arrayEntry OBJECT-TYPE An Entry in the array Table. | 1.3.6.1.4.1.3582.5.1.4.3.3.2.1 | not-accessible | optional | |
| arrayID OBJECT-TYPE The unique array ID | 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.1 | INTEGER | read-only | optional |
| arrSize OBJECT-TYPE Size in MB | 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.2 | INTEGER | read-only | optional |
| arrNumDrives OBJECT-TYPE Number of drives for this array | 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.3 | INTEGER | read-only | optional |
| arrayRef OBJECT-TYPE Tag for the array | 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.4 | INTEGER | read-only | optional |
| pdList OBJECT-TYPE Space separated pd identification. e.g. {devID devID devID} etc | 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.5 | DisplayString | read-only | optional |
| arrAdpId OBJECT-TYPE Adapter where the array will be found | 1.3.6.1.4.1.3582.5.1.4.3.3.2.1.6 | INTEGER | read-only | optional |
| spareInfo OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.3.4 | |||
| spareDevNumber OBJECT-TYPE The present number of rows in the sparepool table. | 1.3.6.1.4.1.3582.5.1.4.3.4.1 | Gauge | read-only | mandatory |
| spareTable OBJECT-TYPE A List of sparepool Entries containing Information/Properties about the spare drive | 1.3.6.1.4.1.3582.5.1.4.3.4.2 | not-accessible | optional | |
| spareEntry OBJECT-TYPE An Entry in the sparepool Table. | 1.3.6.1.4.1.3582.5.1.4.3.4.2.1 | not-accessible | optional | |
| spareID OBJECT-TYPE The unique Index | 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.1 | INTEGER | read-only | optional |
| deviceIdentification OBJECT-TYPE The Device ID | 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.2 | INTEGER | read-only | optional |
| spareType OBJECT-TYPE Spare type. isDedicated(0/1)isRevertible(0/1)isEnclAffinity(0/1). 1 implies particular feature is enable and 0 represent feature is disable. | 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.3 | DisplayString | read-only | optional |
| arrayCount OBJECT-TYPE The number of arrays to which the PD can be dedicated | 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.4 | INTEGER | read-only | optional |
| arrRef OBJECT-TYPE Comma separated array ids. e.g. 2,4,5 etc | 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.5 | DisplayString | read-only | optional |
| sprAdpId OBJECT-TYPE Adapter where the spare will be found | 1.3.6.1.4.1.3582.5.1.4.3.4.2.1.6 | INTEGER | read-only | optional |
| enclosure OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.4 | |||
| enclosureInfo OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.4.1 | |||
| enclosureNumber OBJECT-TYPE The present number of rows in the enclosure table. | 1.3.6.1.4.1.3582.5.1.4.4.1.1 | Gauge | read-only | mandatory |
| enclosureTable OBJECT-TYPE A List of enclosure Entries containing Information/Properties about the enclosures in the system. | 1.3.6.1.4.1.3582.5.1.4.4.1.2 | not-accessible | optional | |
| enclosureEntry OBJECT-TYPE An Entry in the enclosure table. | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1 | not-accessible | mandatory | |
| enclosureID OBJECT-TYPE EnclosureID for this enclosure.(Unique) | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.1 | INTEGER | read-only | optional |
| deviceId OBJECT-TYPE Enclosure device Id. | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.2 | INTEGER | read-only | optional |
| enclosureIndex OBJECT-TYPE Firmware internal enclosure index | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.3 | INTEGER | read-only | optional |
| slotCount OBJECT-TYPE Number of slots | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.4 | INTEGER | read-only | optional |
| psCount OBJECT-TYPE Number of power supplies | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.5 | INTEGER | read-only | optional |
| fanCount OBJECT-TYPE Number of fans | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.6 | INTEGER | read-only | optional |
| tempSensorCount OBJECT-TYPE Number of temperature sensors | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.7 | INTEGER | read-only | optional |
| alarmCount OBJECT-TYPE Number of alarms | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.8 | INTEGER | read-only | optional |
| simCount OBJECT-TYPE Number of SIM modules | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.9 | INTEGER | read-only | optional |
| isFault OBJECT-TYPE Enclosure has entered a FAULT state or not. Values: false(0), true(1) | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.10 | INTEGER | read-only | optional |
| pdCount OBJECT-TYPE Number of physical drives present | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.11 | INTEGER | read-only | optional |
| pdIds OBJECT-TYPE Physical drive deviceId's comma separated. | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.12 | DisplayString | read-only | optional |
| encAdpID OBJECT-TYPE Adapter ID where this enclosure is connected | 1.3.6.1.4.1.3582.5.1.4.4.1.2.1.13 | INTEGER | read-only | optional |
| enclosureFanInfo OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.4.2 | |||
| enclosureFanNumber OBJECT-TYPE The present number of rows in the enclosure fan table. | 1.3.6.1.4.1.3582.5.1.4.4.2.1 | Gauge | read-only | mandatory |
| enclosureFanTable OBJECT-TYPE A List of fan Entries containing Information/Properties about the enclosureFan. | 1.3.6.1.4.1.3582.5.1.4.4.2.2 | not-accessible | optional | |
| enclosureFanEntry OBJECT-TYPE An Entry in the enclosureFan table. | 1.3.6.1.4.1.3582.5.1.4.4.2.2.1 | not-accessible | mandatory | |
| fanID OBJECT-TYPE ID for this enclosureFan.(Unique) | 1.3.6.1.4.1.3582.5.1.4.4.2.2.1.1 | INTEGER | read-only | optional |
| enclosureId OBJECT-TYPE Enclosure ID where the fan is attached | 1.3.6.1.4.1.3582.5.1.4.4.2.2.1.2 | INTEGER | read-only | optional |
| fanStatus OBJECT-TYPE status of the device | 1.3.6.1.4.1.3582.5.1.4.4.2.2.1.3 | INTEGER {status-ok(1), status-critical(2), status-nonCritical(3), status-unrecoverable(4), status-not-installed(5), status-unknown(6), status-not-available(7)} | read-only | optional |
| enclosureSlotInfo OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.4.3 | |||
| enclosureSlotNum OBJECT-TYPE The present number of rows in the enclosure slot table. | 1.3.6.1.4.1.3582.5.1.4.4.3.1 | Gauge | read-only | mandatory |
| enclosureSlotTable OBJECT-TYPE A List of slot Entries containing Information/Properties about the enclosure slots. | 1.3.6.1.4.1.3582.5.1.4.4.3.2 | not-accessible | optional | |
| enclosureSlotEntry OBJECT-TYPE An Entry in the enclosureSlot table. | 1.3.6.1.4.1.3582.5.1.4.4.3.2.1 | not-accessible | mandatory | |
| slotID OBJECT-TYPE ID for this slot.(Unique) | 1.3.6.1.4.1.3582.5.1.4.4.3.2.1.1 | INTEGER | read-only | optional |
| sltEncId OBJECT-TYPE Enclosure ID where the slot | 1.3.6.1.4.1.3582.5.1.4.4.3.2.1.2 | INTEGER | read-only | optional |
| slotStatus OBJECT-TYPE status of the device. Values: status-ok(1), status-critical(2), status-nonCritical(3), status-unrecoverable(4), status-not-installed(5), status-unknown(6), status-not-available(7) | 1.3.6.1.4.1.3582.5.1.4.4.3.2.1.3 | INTEGER {status-ok(1), status-critical(2), status-nonCritical(3), status-unrecoverable(4), status-not-installed(5), status-unknown(6), status-not-available(7)} | read-only | optional |
| enclosurePSInfo OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.4.4 | |||
| enclosurePSNumber OBJECT-TYPE The present number of rows in the enclosure fan table. | 1.3.6.1.4.1.3582.5.1.4.4.4.1 | Gauge | read-only | mandatory |
| enclosurePSTable OBJECT-TYPE A List of powerSupply Entries containing Information/Properties about the enclosure powerSupply | 1.3.6.1.4.1.3582.5.1.4.4.4.2 | not-accessible | optional | |
| enclosurePSEntry OBJECT-TYPE An Entry in the powerSupply table. | 1.3.6.1.4.1.3582.5.1.4.4.4.2.1 | not-accessible | mandatory | |
| powerSupplyID OBJECT-TYPE ID for this powerSupply.(Unique) | 1.3.6.1.4.1.3582.5.1.4.4.4.2.1.1 | INTEGER | read-only | optional |
| psEnclosureId OBJECT-TYPE Enclosure id for the powerSupply | 1.3.6.1.4.1.3582.5.1.4.4.4.2.1.2 | INTEGER | read-only | optional |
| powerSupplyStatus OBJECT-TYPE status of the power Supply | 1.3.6.1.4.1.3582.5.1.4.4.4.2.1.3 | INTEGER {status-ok(1), status-critical(2), status-nonCritical(3), status-unrecoverable(4), status-not-installed(5), status-unknown(6), status-not-available(7)} | read-only | optional |
| enclosureTSInfo OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.4.5 | |||
| enclosureTSNumber OBJECT-TYPE The present number of rows in the enclosure fan table. | 1.3.6.1.4.1.3582.5.1.4.4.5.1 | Gauge | read-only | mandatory |
| enclosureTSTable OBJECT-TYPE A List of TempSensor Entries containing Information/Properties about the enclosure TempSensor | 1.3.6.1.4.1.3582.5.1.4.4.5.2 | not-accessible | optional | |
| enclosureTSEntry OBJECT-TYPE An Entry in the adapter table. | 1.3.6.1.4.1.3582.5.1.4.4.5.2.1 | not-accessible | mandatory | |
| tempSensorID OBJECT-TYPE ID for this TempSensor.(Unique) | 1.3.6.1.4.1.3582.5.1.4.4.5.2.1.1 | INTEGER | read-only | optional |
| encId OBJECT-TYPE enclosure id for this TempSensor | 1.3.6.1.4.1.3582.5.1.4.4.5.2.1.2 | INTEGER | read-only | optional |
| tempSensorStatus OBJECT-TYPE status of this tempSensor | 1.3.6.1.4.1.3582.5.1.4.4.5.2.1.3 | INTEGER {status-ok(1), status-critical(2), status-nonCritical(3), status-unrecoverable(4), status-not-installed(5), status-unknown(6), status-not-available(7)} | read-only | optional |
| tsTemperature OBJECT-TYPE Current temperature in degree Centigrade | 1.3.6.1.4.1.3582.5.1.4.4.5.2.1.4 | INTEGER | read-only | optional |
| enclosureAlarmInfo OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.4.6 | |||
| enclosureAlarmNumber OBJECT-TYPE The present number of rows in the enclosure fan table. | 1.3.6.1.4.1.3582.5.1.4.4.6.1 | Gauge | read-only | mandatory |
| enclosureAlarmTable OBJECT-TYPE A List of Alarm Entries containing Information/Properties about enclosure Alarms | 1.3.6.1.4.1.3582.5.1.4.4.6.2 | not-accessible | optional | |
| enclosureAlarmEntry OBJECT-TYPE An Entry in the enclosureAlarm table. | 1.3.6.1.4.1.3582.5.1.4.4.6.2.1 | not-accessible | mandatory | |
| alarmID OBJECT-TYPE ID for this Alarm.(Unique) | 1.3.6.1.4.1.3582.5.1.4.4.6.2.1.1 | INTEGER | read-only | optional |
| almEnclosureId OBJECT-TYPE Enclosure id where the Alarm is attached | 1.3.6.1.4.1.3582.5.1.4.4.6.2.1.2 | INTEGER | read-only | optional |
| alarmStatus OBJECT-TYPE Status of the alarm | 1.3.6.1.4.1.3582.5.1.4.4.6.2.1.3 | INTEGER {status-ok(1), status-critical(2), status-nonCritical(3), status-unrecoverable(4), status-not-installed(5), status-unknown(6), status-not-available(7)} | read-only | optional |
| enclosureSIMInfo OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.4.7 | |||
| enclosureSIMNumber OBJECT-TYPE The present number of rows in the enclosure fan table. | 1.3.6.1.4.1.3582.5.1.4.4.7.1 | Gauge | read-only | mandatory |
| enclosureSIMTable OBJECT-TYPE A List of SIM Entries containing Information/Properties about enclosure SIMs | 1.3.6.1.4.1.3582.5.1.4.4.7.2 | not-accessible | optional | |
| enclosureSIMEntry OBJECT-TYPE An Entry in the enclosureSIM table. | 1.3.6.1.4.1.3582.5.1.4.4.7.2.1 | not-accessible | mandatory | |
| simID OBJECT-TYPE ID for this SIM.(Unique) | 1.3.6.1.4.1.3582.5.1.4.4.7.2.1.1 | INTEGER | read-only | optional |
| simEnclosureId OBJECT-TYPE Enclosure id where the SIM is attached | 1.3.6.1.4.1.3582.5.1.4.4.7.2.1.2 | INTEGER | read-only | optional |
| simStatus OBJECT-TYPE Number of Logical Drives Configured on this Adapter. | 1.3.6.1.4.1.3582.5.1.4.4.7.2.1.3 | INTEGER {status-ok(1), status-critical(2), status-nonCritical(3), status-unrecoverable(4), status-not-installed(5), status-unknown(6), status-not-available(7)} | read-only | optional |
| topology OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.5 | |||
| phyInfo OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.5.1 | |||
| phyNumber OBJECT-TYPE The present number of rows in the Phy table. | 1.3.6.1.4.1.3582.5.1.4.5.1.1 | Gauge | read-only | mandatory |
| phyTable OBJECT-TYPE A List of phy Entries containing Information/Properties about the sas topology in the system. | 1.3.6.1.4.1.3582.5.1.4.5.1.2 | not-accessible | optional | |
| phyEntry OBJECT-TYPE An Entry in the Phy table. | 1.3.6.1.4.1.3582.5.1.4.5.1.2.1 | not-accessible | mandatory | |
| phyIndex OBJECT-TYPE Index for this phy.(Unique) | 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.1 | INTEGER | read-only | optional |
| deviceIndex OBJECT-TYPE Index of the device in tDeviceTable where the phy is attached | 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.2 | INTEGER | read-only | optional |
| deviceType OBJECT-TYPE Type of device attached to this phy NO_DEVICE = 0, IOC(1), EDGE_EXPANDER(2), FANOUT_EXPANDER(3),END_DEVICE(4) | 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.3 | INTEGER | read-only | optional |
| phyID OBJECT-TYPE The phy ID of the attached device | 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.4 | INTEGER | read-only | optional |
| deviceOffset OBJECT-TYPE The memory offset where the node of the device that is attached to this phy starts. | 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.5 | INTEGER | read-only | optional |
| phyPos OBJECT-TYPE Position of the Phy in device attached. | 1.3.6.1.4.1.3582.5.1.4.5.1.2.1.6 | INTEGER | read-only | optional |
| devicesInTopology OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.5.2 | |||
| tDeviceNumber OBJECT-TYPE The present number of rows in the topology Device table. | 1.3.6.1.4.1.3582.5.1.4.5.2.1 | Gauge | read-only | mandatory |
| tDeviceTable OBJECT-TYPE A List of device Entries containing Information/Properties about the sas topology in the system. | 1.3.6.1.4.1.3582.5.1.4.5.2.2 | not-accessible | optional | |
| tDeviceEntry OBJECT-TYPE An Entry in the tDevice table. | 1.3.6.1.4.1.3582.5.1.4.5.2.2.1 | not-accessible | mandatory | |
| tDeviceIndex OBJECT-TYPE Index for this device.(Unique) | 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.1 | INTEGER | read-only | optional |
| contID OBJECT-TYPE Adapter ID where this device is attached | 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.2 | INTEGER | read-only | optional |
| tDeviceId OBJECT-TYPE Device ID. | 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.3 | INTEGER | read-only | optional |
| tDeviceType OBJECT-TYPE NO_DEVICE = 0, IOC(1), EDGE_EXPANDER(2), FANOUT_EXPANDER(3),END_DEVICE(4) | 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.4 | INTEGER | read-only | optional |
| tParentIndex OBJECT-TYPE Index of the parent device in the table where this device is connected. -1 if it root device. | 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.5 | INTEGER | read-only | optional |
| tNumPhy OBJECT-TYPE Total no of Phy present in this device | 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.6 | INTEGER | read-only | optional |
| tSASAddr OBJECT-TYPE Device SAS addresses. Comma separeted for multiple address | 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.7 | DisplayString | read-only | optional |
| tDevDescription OBJECT-TYPE Detailed description of the Device. | 1.3.6.1.4.1.3582.5.1.4.5.2.2.1.8 | DisplayString | read-only | optional |
| lsi_SAS_Traps OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.4.6 | |||
| atAdpNumber OBJECT-TYPE Adapter ID for which Trap is generated. | 1.3.6.1.4.1.3582.5.1.4.6.1001 | INTEGER | read-only | optional |
| atAlarmState OBJECT-TYPE Alarm disabled(0)/enabled(1) | 1.3.6.1.4.1.3582.5.1.4.6.1002 | INTEGER | read-only | optional |
| atRate OBJECT-TYPE BGI/Check Consistency/Rebuild/Patrol Read/Reconstruction Rate | 1.3.6.1.4.1.3582.5.1.4.6.1003 | INTEGER | read-only | optional |
| atFlashImageName OBJECT-TYPE Flash Image Name | 1.3.6.1.4.1.3582.5.1.4.6.1004 | DisplayString | read-only | optional |
| atSensorNum OBJECT-TYPE Sensor Number | 1.3.6.1.4.1.3582.5.1.4.6.1005 | INTEGER | read-only | optional |
| atThreshold OBJECT-TYPE Threshold | 1.3.6.1.4.1.3582.5.1.4.6.1006 | INTEGER | read-only | optional |
| atTemperature OBJECT-TYPE Temperature Exceeded | 1.3.6.1.4.1.3582.5.1.4.6.1007 | INTEGER | read-only | optional |
| devLife OBJECT-TYPE Drive Life | 1.3.6.1.4.1.3582.5.1.4.6.1008 | INTEGER | read-only | optional |
| atWarningLevel OBJECT-TYPE Warning Level | 1.3.6.1.4.1.3582.5.1.4.6.1009 | INTEGER | read-only | optional |
| atErrorLevel OBJECT-TYPE Error Level | 1.3.6.1.4.1.3582.5.1.4.6.1010 | INTEGER | read-only | optional |
| Throttle OBJECT-TYPE Throttle | 1.3.6.1.4.1.3582.5.1.4.6.1011 | INTEGER | read-only | optional |
| PercentThrottle OBJECT-TYPE Percent Throttle | 1.3.6.1.4.1.3582.5.1.4.6.1012 | INTEGER | read-only | optional |
| PCISlotAvailPower OBJECT-TYPE PCI Slot Avail Power | 1.3.6.1.4.1.3582.5.1.4.6.1013 | INTEGER | read-only | optional |
| Flags OBJECT-TYPE Flags SENSOR(1)|SLOT(2) | 1.3.6.1.4.1.3582.5.1.4.6.1014 | INTEGER | read-only | optional |
| SensorOrSlot OBJECT-TYPE Sensor Or Slot depending on the value of thr Flag | 1.3.6.1.4.1.3582.5.1.4.6.1015 | INTEGER | read-only | optional |
| CurrTemp OBJECT-TYPE Current Temp | 1.3.6.1.4.1.3582.5.1.4.6.1016 | INTEGER | read-only | optional |
| ThresholdTemp OBJECT-TYPE Threshold Temp | 1.3.6.1.4.1.3582.5.1.4.6.1017 | INTEGER | read-only | optional |
| vdNum OBJECT-TYPE Virtual Drive Target ID for which Trap is generated. | 1.3.6.1.4.1.3582.5.1.4.6.1101 | INTEGER | read-only | optional |
| vdSeq OBJECT-TYPE Virtual Drive Sequence no for which Trap is generated. | 1.3.6.1.4.1.3582.5.1.4.6.1102 | INTEGER | read-only | optional |
| vdProg OBJECT-TYPE progress % | 1.3.6.1.4.1.3582.5.1.4.6.1103 | INTEGER | read-only | optional |
| vdCachePolicyChangeReason OBJECT-TYPE Virtual Drive cache policy. | 1.3.6.1.4.1.3582.5.1.4.6.1104 | DisplayString | read-only | optional |
| vdNewState OBJECT-TYPE Virtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3) | 1.3.6.1.4.1.3582.5.1.4.6.1105 | INTEGER | read-only | optional |
| vdOldState OBJECT-TYPE Virtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3) | 1.3.6.1.4.1.3582.5.1.4.6.1106 | INTEGER | read-only | optional |
| pdID OBJECT-TYPE Device ID for which Trap is generated. | 1.3.6.1.4.1.3582.5.1.4.6.1201 | INTEGER | read-only | optional |
| pdEncIndex OBJECT-TYPE Enclosure index(0 means not within an enclosure) for which Trap is generated. | 1.3.6.1.4.1.3582.5.1.4.6.1202 | INTEGER | read-only | optional |
| pdSlotNo OBJECT-TYPE Slot no for the enclosure | 1.3.6.1.4.1.3582.5.1.4.6.1203 | INTEGER | read-only | optional |
| pdNewState OBJECT-TYPE Physical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64) | 1.3.6.1.4.1.3582.5.1.4.6.1204 | INTEGER | read-only | optional |
| pdOldState OBJECT-TYPE Physical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64) | 1.3.6.1.4.1.3582.5.1.4.6.1205 | INTEGER | read-only | optional |
| pdCDBData OBJECT-TYPE CDB Data. | 1.3.6.1.4.1.3582.5.1.4.6.1206 | DisplayString | read-only | optional |
| pdSenseData OBJECT-TYPE Sence Data. | 1.3.6.1.4.1.3582.5.1.4.6.1207 | DisplayString | read-only | optional |
| copyrightInfo OBJECT-IDENTITY | 1.3.6.1.4.1.3582.5.1.8 | |||
| copyright OBJECT-TYPE LSI LOGIC | 1.3.6.1.4.1.3582.5.1.8.1 | DisplayString (SIZE(0..63)) | read-only | mandatory |
Notifications
| Name | OID | Status |
|---|---|---|
| irAdpAlarmStateEnabled NOTIFICATION-TYPE Alarm has been enabled by user for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7001 | |
| irAdpBGIRateChanged NOTIFICATION-TYPE Background initialization rate changed to $1 for Adapter $2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7002 | |
| irAdpCacheDiscarded NOTIFICATION-TYPE Controller $1 cache discarded due to memory/battery problems | 1.3.6.1.4.1.3582.5.1.4.6.0.7003 | |
| irAdpCacheRebootCantRecover NOTIFICATION-TYPE Unable to recover cache data due to configuration mismatch for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7004 | |
| irAdpCacheRebootRecover NOTIFICATION-TYPE Cache data recovered successfully for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7005 | |
| irAdpCacheVersionMismatch NOTIFICATION-TYPE Controller cache discarded due to firmware version incompatibility for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7006 | |
| irAdpCCRateChanged NOTIFICATION-TYPE Consistency Check rate changed to $1 for Adapter $2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7007 | |
| irAdpFlashBadImage NOTIFICATION-TYPE Flash downloaded image corrupted for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7008 | |
| irAdpFlashEraseError NOTIFICATION-TYPE Flash erase error for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7009 | |
| irAdpFlashEraseTimeout NOTIFICATION-TYPE Flash timeout during erase for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7010 | |
| irAdpFlashGeneralError NOTIFICATION-TYPE Flash error for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7011 | |
| irAdpFlashImage NOTIFICATION-TYPE Flashing image: $1 for Adapter $2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7012 | |
| irAdpFlashOK NOTIFICATION-TYPE Flash of new firmware image(s)complete for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7013 | |
| irAdpFlashProgramError NOTIFICATION-TYPE Flash programming error for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7014 | |
| irAdpFlashProgramTimeout NOTIFICATION-TYPE Flash timeout during programming for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7015 | |
| irAdpLogCleared NOTIFICATION-TYPE Event log cleared for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7016 | |
| irAdpLogWrapped NOTIFICATION-TYPE Event log wrapped for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7017 | |
| irAdpPatrolReadComplete NOTIFICATION-TYPE Patrol Read complete for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7018 | |
| irAdpPatrolReadPaused NOTIFICATION-TYPE Patrol Read paused for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7019 | |
| irAdpPatrolReadResumed NOTIFICATION-TYPE Patrol Read resumed for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7020 | |
| irAdpPatrolReadStarted NOTIFICATION-TYPE Patrol Read started for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7021 | |
| irAdpShutdown NOTIFICATION-TYPE Shutdown command received for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7022 | |
| irAdpHibernate NOTIFICATION-TYPE Hibernate command received for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7023 | |
| irAdpCrash NOTIFICATION-TYPE Fatal error received for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7024 | |
| irAdpRRChanged NOTIFICATION-TYPE Rebuild rate changed to $1 for Adapter $2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7025 | |
| irAdpPRRateChanged NOTIFICATION-TYPE Patrol Read rate changed to $1 for Adapter $2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7026 | |
| irAdpAlarmStateDisabled NOTIFICATION-TYPE Alarm has been disabled by user for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7027 | |
| irAdpConfigCleared NOTIFICATION-TYPE Configuration cleared for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7028 | |
| irAdpReconRateChanged NOTIFICATION-TYPE Reconstruction rate changed to $1 for Adapter $2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7029 | |
| irAdpDefault NOTIFICATION-TYPE Factory defaults restored for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7030 | |
| irAdpThresholdsExceededCritical NOTIFICATION-TYPE Adapter $1 on sensor $2 has exceeded critical temperature threshold $3 Temperature $4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7031 | |
| irAdpThresholdsExceededWarning NOTIFICATION-TYPE Adapter $1 on sensor $2 has exceeded warning temperature threshold $3 Temperature $4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7032 | |
| irAdpBRMFailed NOTIFICATION-TYPE Backup Rail Monitor has failed for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7033 | |
| irAdpSSDLifeExhausted NOTIFICATION-TYPE Adapter $1 SSD Life for SlotNo $2 PD ID $3 Dev Life $4 Warning Level $5 Error Level $6 | 1.3.6.1.4.1.3582.5.1.4.6.0.7034 | |
| irAdpSSDLifeWarning NOTIFICATION-TYPE Adapter $1 SSD Life for SlotNo $2 PD ID $3 Dev Life $4 Warning Level $5 Error Level $6 | 1.3.6.1.4.1.3582.5.1.4.6.0.7035 | |
| irAdpSSDThrottlingRemoved NOTIFICATION-TYPE Throttling Removed for Adapter $1 PD Slot No $2 Dev ID $3 Throttle $4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7036 | |
| irAdpSSDThrottlingOccuring NOTIFICATION-TYPE Throttling Occuring for Adapter $1 PD Slot No $2 Dev ID $3 Throttle $4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7037 | |
| irAdpPowerThrottlingRemoved NOTIFICATION-TYPE Power Throttling is Removed for Adapter $1 Percent Throttle $2 PCISlotAvailPower $3 | 1.3.6.1.4.1.3582.5.1.4.6.0.7038 | |
| irAdpPowerThrottlingOccuring NOTIFICATION-TYPE Power Throttling is Occuring for Adapter $1 Percent Throttle $2 PCISlotAvailPower $3 | 1.3.6.1.4.1.3582.5.1.4.6.0.7039 | |
| irAdpDFFTempExceededWarning NOTIFICATION-TYPE Adapter $1 Flags $2 SensorOrSlot $3 CurrTemp $4 ThresholdTemp $5 pdID $6 | 1.3.6.1.4.1.3582.5.1.4.6.0.7040 | |
| irAdpDFFTempExceededCritical NOTIFICATION-TYPE Adapter $1 Flags $2 SensorOrSlot $3 CurrTemp $4 ThresholdTemp $5 pdID $6 | 1.3.6.1.4.1.3582.5.1.4.6.0.7041 | |
| irVdtBGIAborted NOTIFICATION-TYPE BGI aborted on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7101 | |
| irVdtBGICompleted NOTIFICATION-TYPE BGI completed on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7102 | |
| irVdtBGIDoneWR NOTIFICATION-TYPE BGI completed with uncorrectable errors on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7103 | |
| irVdtBGIFailed NOTIFICATION-TYPE BGI failed on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7104 | |
| irVdtBGIStarted NOTIFICATION-TYPE BGI started on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7105 | |
| irVdtCCStarted NOTIFICATION-TYPE CC started on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7107 | |
| irVdtCCCompleted NOTIFICATION-TYPE CC completed on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7108 | |
| irVdtCCFailed NOTIFICATION-TYPE CC failed on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7109 | |
| irVdtCCAborted NOTIFICATION-TYPE CC aborted on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7110 | |
| irVdtCCCompCor NOTIFICATION-TYPE CC completed with correction on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7111 | |
| irVdtInitAborted NOTIFICATION-TYPE Initialization aborted on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7112 | |
| irVdtInitFailed NOTIFICATION-TYPE Initialization failed on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7113 | |
| irVdtInitCompleted NOTIFICATION-TYPE Initialization completed on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7114 | |
| irVdtInitFastStarted NOTIFICATION-TYPE Fast Initialization started on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7115 | |
| irVdtInitFullStarted NOTIFICATION-TYPE Full Initialization started on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7116 | |
| irVdtReconStarted NOTIFICATION-TYPE Reconstructoin started on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7117 | |
| irVdtReconCompleted NOTIFICATION-TYPE Reconstruction completed on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7118 | |
| irVdtReconResumed NOTIFICATION-TYPE Reconstruction resumed on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7119 | |
| irVdtReconStopped NOTIFICATION-TYPE Reconstruction stopped on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7120 | |
| irVdtStateChange NOTIFICATION-TYPE VD state changed on Adapter -$1 VD Target -$2 from $3 to $4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7121 | |
| irVdtCreated NOTIFICATION-TYPE A new VD created on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7122 | |
| irVdtDeleted NOTIFICATION-TYPE A VD deleted on Adapter -$1 VD Target -$2 | 1.3.6.1.4.1.3582.5.1.4.6.0.7123 | |
| irPdtClearAborted NOTIFICATION-TYPE PD Clear aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7201 | |
| irPdtClearFailed NOTIFICATION-TYPE PD Clear failed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7202 | |
| irPdtClearStarted NOTIFICATION-TYPE PD Clear started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7203 | |
| irPdtClearCompleted NOTIFICATION-TYPE PD Clear completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7204 | |
| irPdtError NOTIFICATION-TYPE Error occurred on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7205 | |
| irPdtFormatStart NOTIFICATION-TYPE PD format started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7206 | |
| irPdtFormatCompleted NOTIFICATION-TYPE PD format completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7207 | |
| irPdtInserted NOTIFICATION-TYPE PD inserted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7208 | |
| irPdtRblAborted NOTIFICATION-TYPE Rebuild aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7209 | |
| irPdtRblCompleted NOTIFICATION-TYPE Rebuild completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7210 | |
| irPdtRblFailedBS NOTIFICATION-TYPE Rebuild failed(bad source) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7211 | |
| irPdtRblFailedBT NOTIFICATION-TYPE Rebuild failed(bad target) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7212 | |
| irPdtRblStart NOTIFICATION-TYPE Rebuild started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7213 | |
| irPdtRblResumed NOTIFICATION-TYPE Rebuild resumed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7214 | |
| irPdtRblStartA NOTIFICATION-TYPE Rebuild started(auto) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7215 | |
| irPdtRemoved NOTIFICATION-TYPE PD removed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7216 | |
| irPdtStateChange NOTIFICATION-TYPE PD state changed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 from $5 to $6 | 1.3.6.1.4.1.3582.5.1.4.6.0.7217 | |
| irPdtSENSEAlert NOTIFICATION-TYPE An unexpected Sense was detected on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 CDBData -$5 SenseData -$6 | 1.3.6.1.4.1.3582.5.1.4.6.0.7218 | |
| irPdtPredictiveThresholdExceed NOTIFICATION-TYPE Predictive Threshold Exceeded on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7219 | |
| irPdSSDSecurityLocked NOTIFICATION-TYPE SSD is in locked state on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7220 | |
| irPdSSDSecurityUnlocked NOTIFICATION-TYPE SSD is in unlocked state on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 | 1.3.6.1.4.1.3582.5.1.4.6.0.7221 | |
| irBbuPresent NOTIFICATION-TYPE Battery Present for Adapter %d | 1.3.6.1.4.1.3582.5.1.4.6.0.7301 | |
| irBbuNotPresent NOTIFICATION-TYPE Battery Not Present for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7302 | |
| irBbuNewBattery NOTIFICATION-TYPE New Battery for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7303 | |
| irBbuReplaced NOTIFICATION-TYPE Battery replaced for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7304 | |
| irBbuTempHigh NOTIFICATION-TYPE Battery temperature high for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7305 | |
| irBbuVoltageLow NOTIFICATION-TYPE Battery voltage low for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7306 | |
| irBbuCharging NOTIFICATION-TYPE Battery started charging for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7307 | |
| irBbuDisCharging NOTIFICATION-TYPE Battery is discharging for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7308 | |
| irBbuTempNormal NOTIFICATION-TYPE Battery temperature is normal for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7309 | |
| irBbuReplace NOTIFICATION-TYPE Battery needs replacement, SOH Bad for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7310 | |
| irBbuRelearnStarted NOTIFICATION-TYPE Battery relearn started for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7311 | |
| irBbuRelearnProgress NOTIFICATION-TYPE Battery relearn in progress for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7312 | |
| irBbuRelearnComplete NOTIFICATION-TYPE Battery relearn completed for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7313 | |
| irBbuRelearnTimeout NOTIFICATION-TYPE Battery relearn timed out for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7314 | |
| irBbuRelearnPending NOTIFICATION-TYPE Battery relearn pending: Battery is under charge for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7315 | |
| irBbuRelearnPostponed NOTIFICATION-TYPE Battery relearn postponed for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7316 | |
| irBbuRemoved NOTIFICATION-TYPE Battery removed for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7317 | |
| irBbuCapacityLow NOTIFICATION-TYPE Current capacity of the battery is below threshold for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7318 | |
| irBbuCapacityAbove NOTIFICATION-TYPE Current capacity of the battery is above threshold for Adapter $1 | 1.3.6.1.4.1.3582.5.1.4.6.0.7319 |