MIBs Depot

LSI-megaRAID-SAS-IR-MIB

Registered at
1.3.6.1.4.1.3582
Namespace
lsi
Source file
LSI-megaRAID-SAS-IR-MIB
Digest
sha256:8262deeec5ddc9648721ff0948d5ef75ab9e6f9abf05ec036fdbdd90df8714b9

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Gauge32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso
SNMPv2-TCDisplayString, PhysAddress, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

LSI-megaRAID-SAS-IR-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
lsi
OBJECT-IDENTITY
1.3.6.1.4.1.3582
lsiStorageComponents
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5
lsiRAIDServer
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1
hostName
OBJECT-TYPE
Name of the host system.
1.3.6.1.4.1.3582.5.1.1DisplayString (SIZE(0..63))read-onlymandatory
hostOSInfo
OBJECT-TYPE
Operating System description where SNMP agent is running.
1.3.6.1.4.1.3582.5.1.2DisplayString (SIZE(0..63))read-onlymandatory
versionInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.3
mibVersion
OBJECT-TYPE
The MIB version no. (xx.yy.zz)
1.3.6.1.4.1.3582.5.1.3.1DisplayString (SIZE(0..63))read-onlymandatory
agentModuleName
OBJECT-TYPE
The agent module name
1.3.6.1.4.1.3582.5.1.3.2DisplayString (SIZE(0..63))read-onlymandatory
agentModuleVersion
OBJECT-TYPE
The module version in xx.yy format. Where xx is the major version number and yy is the minor version number(without build information).
1.3.6.1.4.1.3582.5.1.3.3DisplayString (SIZE(0..63))read-onlymandatory
releaseDate
OBJECT-TYPE
Module Release Date (DD/MM/YYYY)
1.3.6.1.4.1.3582.5.1.3.4DisplayString (SIZE(0..63))read-onlymandatory
megaRAID_SAS_IR
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4
adapter
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.1
adapterDetails
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.1.1
adpNumber
OBJECT-TYPE
The total no of SAS adapters present.
1.3.6.1.4.1.3582.5.1.4.1.1.1Gaugeread-onlymandatory
adapterPropertiesTable
OBJECT-TYPE
A List of adapter Entries containing Information/Properties about the adapters.
1.3.6.1.4.1.3582.5.1.4.1.1.2not-accessibleoptional
adapterPropertiesEntry
OBJECT-TYPE
An Entry in the adapter table.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1not-accessiblemandatory
adapterID
OBJECT-TYPE
AdapterID for this Adapter.(Unique)
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.1INTEGERread-onlyoptional
rebuildRate
OBJECT-TYPE
Rebuild rate on this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.2INTEGERread-onlyoptional
reconstructionRate
OBJECT-TYPE
Reconstruction rate on this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.3INTEGERread-onlyoptional
alarmState
OBJECT-TYPE
Alarm is enabled(1) or disabled(0) on this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.4INTEGERread-onlyoptional
cacheFlushInterval
OBJECT-TYPE
Cache flush interval in seconds for this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.5INTEGERread-onlyoptional
clusterState
OBJECT-TYPE
Cluster is enabled(1) or disabled(0) on this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.6INTEGERread-onlyoptional
predFailPollInterval
OBJECT-TYPE
Number of seconds between predictive fail polls on this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.7INTEGERread-onlyoptional
intThrottleCount
OBJECT-TYPE
Interrupt throttle active count on this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.8INTEGERread-onlyoptional
intThrottleTimeUs
OBJECT-TYPE
Interrupt throttle completion hold time on this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.9INTEGERread-onlyoptional
patrolReadRate
OBJECT-TYPE
Patrol Read Rate for this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.10INTEGERread-onlyoptional
bgiRate
OBJECT-TYPE
Background initialization rate for this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.11INTEGERread-onlyoptional
ccRate
OBJECT-TYPE
Consistency Check rate on this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.12INTEGERread-onlyoptional
spinupDelay
OBJECT-TYPE
Number of seconds to delay among spinup groups for this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.13INTEGERread-onlyoptional
spinupDriveCount
OBJECT-TYPE
Maximum number of drives to spin up at one time for this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.14INTEGERread-onlyoptional
coercionMode
OBJECT-TYPE
Drive capacity coercion mode. 0->None; 1->128MB; 2->1GB; 3->Adaptive Coercion.
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.15INTEGERread-onlyoptional
disableAutoRebuild
OBJECT-TYPE
auto-rebuild and hot-spare commissioning status. 1->Disable , 0->Enable
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.16INTEGERread-onlyoptional
disableBatteryWarning
OBJECT-TYPE
disable/enable warnings for missing battery or missing HW status. 1->Disable , 0->Enable
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.17INTEGERread-onlyoptional
multipathSupport
OBJECT-TYPE
Multipath is supported or not supported on this adapter.Values: not supported(0),supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.18INTEGERread-onlyoptional
ssdSMARTerEnabled
OBJECT-TYPE
Copyback to SSD on SMART error. Values Enabled(0),Disabled(1)
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.19INTEGERread-onlyoptional
sasAddr
OBJECT-TYPE
This field gives the controller SAS address
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.20DisplayStringread-onlyoptional
auxilaryPowerPresent
OBJECT-TYPE
Presence of Auxilary Power
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.21DisplayStringread-onlyoptional
ddLifeCurveStatus
OBJECT-TYPE
Check for throttling
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.22DisplayStringread-onlyoptional
ddSSDLifeLeft
OBJECT-TYPE
Percentage of SSD life left
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.23DisplayStringread-onlyoptional
dDStatus
OBJECT-TYPE
Overall DD status
1.3.6.1.4.1.3582.5.1.4.1.1.2.1.24DisplayStringread-onlyoptional
adapterInfoTable
OBJECT-TYPE
A List of adapter Entries containing Information/Properties about the adapters.
1.3.6.1.4.1.3582.5.1.4.1.1.3not-accessibleoptional
adapterInfoEntry
OBJECT-TYPE
An Entry in the adapterInfo table.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1not-accessiblemandatory
infAdpID
OBJECT-TYPE
AdapterID for this Adapter.(Unique)
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.1INTEGERread-onlyoptional
vendorId
OBJECT-TYPE
PCI Vendor ID for this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.2INTEGERread-onlyoptional
devId
OBJECT-TYPE
PCI Device ID for this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.3INTEGERread-onlyoptional
subVendorID
OBJECT-TYPE
PCI Sub-Vendor ID for this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.4INTEGERread-onlyoptional
subDevID
OBJECT-TYPE
PCI Sub-Device ID for this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.5INTEGERread-onlyoptional
hostInterface
OBJECT-TYPE
Host interface information for this adapter. Values are as follows: N/A(0), PCIX(1), PCIE(2), iSCSI(3), SAS_3G(4)
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.6INTEGERread-onlyoptional
hostInterfacePortCnt
OBJECT-TYPE
Port Count on this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.7INTEGERread-onlyoptional
hostInterfacePortAddr
OBJECT-TYPE
Port address comma delimited
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.8DisplayStringread-onlyoptional
devInterface
OBJECT-TYPE
Multiple device interface support values separated by space.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.9DisplayStringread-onlyoptional
devInterfacePortCnt
OBJECT-TYPE
Device Port Count on this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.10INTEGERread-onlyoptional
devInterfacePortAddr
OBJECT-TYPE
Device Port address comma delimited
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.11DisplayStringread-onlyoptional
productName
OBJECT-TYPE
Product name e.g. SAS2008 B1.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.12DisplayStringread-onlyoptional
serialNo
OBJECT-TYPE
Controller serial number
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.13DisplayStringread-onlyoptional
firmwareVersion
OBJECT-TYPE
Firmware version Format->(Firmware Package Version:Version:Date:Time)
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.14DisplayStringread-onlyoptional
driverVersion
OBJECT-TYPE
Driver version Format->(Driver Name:Version)
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.15DisplayStringread-onlyoptional
nvramSize
OBJECT-TYPE
NVRAM size in KB for this adapter.A value -1 for invalid or undefined size.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.16INTEGERread-onlyoptional
memorySize
OBJECT-TYPE
Memory size in MB for this adapter.A value -1 for invalid or undefined size.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.17INTEGERread-onlyoptional
flashSize
OBJECT-TYPE
Flash size in MB for this adapter.A value -1 for invalid or undefined size.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.18INTEGERread-onlyoptional
vdPresentCount
OBJECT-TYPE
Virtual devices present in this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.19INTEGERread-onlyoptional
vdDegradedCount
OBJECT-TYPE
Number of virtual devices in this adapter that are critical
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.20INTEGERread-onlyoptional
vdOfflineCount
OBJECT-TYPE
Number of virtual devices in this adapter that are offline
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.21INTEGERread-onlyoptional
pdPresentCount
OBJECT-TYPE
Physical devices present in this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.22INTEGERread-onlyoptional
pdDiskPresentCount
OBJECT-TYPE
Physical disk devices present in this adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.23INTEGERread-onlyoptional
pdDiskPredFailureCount
OBJECT-TYPE
Number of disk devices in this adapter that are critical
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.24INTEGERread-onlyoptional
pdDiskFailedCount
OBJECT-TYPE
Number of disk devices in this adapter that are failed
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.25INTEGERread-onlyoptional
clusterStatus
OBJECT-TYPE
Cluster state on this adapter. Values: ACTIVE(1), INACTIVE(0)
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.26INTEGERread-onlyoptional
devInterfaceType
OBJECT-TYPE
Type of the interface of the IR adapter. Values: GEN1(0), GEN2(1)
1.3.6.1.4.1.3582.5.1.4.1.1.3.1.27INTEGERread-onlyoptional
adapterSupportInfoTable
OBJECT-TYPE
A List of Entries containing Properties supported by the Controller.
1.3.6.1.4.1.3582.5.1.4.1.1.4not-accessibleoptional
adapterSupportInfoEntry
OBJECT-TYPE
An Entry in the adapter table.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1not-accessiblemandatory
suAdpID
OBJECT-TYPE
AdapterID for this Adapter.(Unique)
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.1INTEGERread-onlyoptional
supportMaxArms
OBJECT-TYPE
Maximum arms per Logical Drive supported for this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.2INTEGERread-onlyoptional
supportMaxSpans
OBJECT-TYPE
Maximum spans per Logical Drive supported for this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.3INTEGERread-onlyoptional
supportMaxArrays
OBJECT-TYPE
Maximum number arrays supported this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.4INTEGERread-onlyoptional
supportMaxLDs
OBJECT-TYPE
Maximum number of Logical Drive's supported for this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.5INTEGERread-onlyoptional
supportHardwarePresent
OBJECT-TYPE
Supported Hardware on this adapter. bbu(1),alarm(2),nvram(3),uart(4). For multiple hardware support a comma delimited list will appear.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.6DisplayStringread-onlyoptional
supportMaxConcurrentCmds
OBJECT-TYPE
The maximum parallel commands supported on this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.7INTEGERread-onlyoptional
supportMaxSGECount
OBJECT-TYPE
The maximum Scatter Gather Element count allowed on this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.8INTEGERread-onlyoptional
supportMaxRequestSize
OBJECT-TYPE
The maximum data transfer size in sectors, on this Adapter.
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.9INTEGERread-onlyoptional
supportClusterPermitted
OBJECT-TYPE
Clustering support on this Adapter. Values: FALSE(0), TRUE(1)
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.10INTEGERread-onlyoptional
supportMinStripeSize
OBJECT-TYPE
Minimum stripe size supported. 0(512),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.11INTEGERread-onlymandatory
supportMaxStripeSize
OBJECT-TYPE
Maximum stripe size supported. 0(512),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.12INTEGERread-onlymandatory
supportSupportsSAS
OBJECT-TYPE
SAS physical drive support.Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.13INTEGERread-onlymandatory
supportSupportsSATA
OBJECT-TYPE
SATA physical drive support.Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.14INTEGERread-onlymandatory
supportAllowMixInEnclosure
OBJECT-TYPE
Mix InEnclosure support.Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.15INTEGERread-onlymandatory
supportAllowMixInVD
OBJECT-TYPE
MixInVD support.Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.16INTEGERread-onlymandatory
supportAllowSataInCluster
OBJECT-TYPE
SataInCluster support. Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.17INTEGERread-onlymandatory
allowSSDMixInLD
OBJECT-TYPE
allow SAS/SATA SSD mix within an LD. allow(1), not allow(0)
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.18INTEGERread-onlymandatory
allowMixSSDHDDInLD
OBJECT-TYPE
allow SSD/HDD mix within an LD.allow(1), not allow(0)
1.3.6.1.4.1.3582.5.1.4.1.1.4.1.19INTEGERread-onlymandatory
adpOperationsSupportInfoTable
OBJECT-TYPE
A List of Entries containing operations supported by the Controller.
1.3.6.1.4.1.3582.5.1.4.1.1.5not-accessibleoptional
adpOperationsSupportInfoEntry
OBJECT-TYPE
An Entry in the adapter table.
1.3.6.1.4.1.3582.5.1.4.1.1.5.1not-accessiblemandatory
opAdpID
OBJECT-TYPE
AdapterID for this Adapter.(Unique)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.1INTEGERread-onlyoptional
rbldRate
OBJECT-TYPE
Rebuilding rate change support for this Adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.2INTEGERread-onlyoptional
suCCRate
OBJECT-TYPE
Consistency Check rate change support for this Adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.3INTEGERread-onlyoptional
suBgiRate
OBJECT-TYPE
Background initialization rate change support for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.4INTEGERread-onlyoptional
reconRate
OBJECT-TYPE
Reconstruction rate change support for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.5INTEGERread-onlyoptional
patrolRate
OBJECT-TYPE
Patrol read rate change support for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.6INTEGERread-onlyoptional
alarmControl
OBJECT-TYPE
Alarm control support for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.7INTEGERread-onlyoptional
clusterSupported
OBJECT-TYPE
Cluster support for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.8INTEGERread-onlyoptional
bbu
OBJECT-TYPE
BBU support for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.9INTEGERread-onlyoptional
spanningAllowed
OBJECT-TYPE
Spanning support for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.10INTEGERread-onlyoptional
dedicatedHotSpares
OBJECT-TYPE
Dedicated HotSpares for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.11INTEGERread-onlyoptional
revertibleHotSpares
OBJECT-TYPE
Revertible HotSpares support for this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.12INTEGERread-onlyoptional
foreignConfigImport
OBJECT-TYPE
Support foreign config import on this adapter. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.13INTEGERread-onlyoptional
selfDiagnostic
OBJECT-TYPE
Controller supports self diagnostic. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.14INTEGERread-onlyoptional
allowMixedRedundancyOnArray
OBJECT-TYPE
Allow different Virtual Disk on the same array to have different redundancy levels Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.15INTEGERread-onlyoptional
globalHotSpares
OBJECT-TYPE
Global hot spares are supported. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.16INTEGERread-onlyoptional
oceWithNoDriveAddition
OBJECT-TYPE
Online Capacity Expansion supported. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.5.1.17INTEGERread-onlyoptional
driveOperationSupportTable
OBJECT-TYPE
A List of operations supported by Physical Drive.
1.3.6.1.4.1.3582.5.1.4.1.1.6not-accessibleoptional
driveOperationSupportEntry
OBJECT-TYPE
An Entry in the driveOperationSupport table.
1.3.6.1.4.1.3582.5.1.4.1.1.6.1not-accessiblemandatory
drvAdpID
OBJECT-TYPE
Unique adapter ID
1.3.6.1.4.1.3582.5.1.4.1.1.6.1.1INTEGERread-onlymandatory
forceOnline
OBJECT-TYPE
Physical Drive force Online operation support Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.6.1.2INTEGERread-onlymandatory
forceOffline
OBJECT-TYPE
Physical Drive force Offline operation support Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.6.1.3INTEGERread-onlymandatory
forceRebuild
OBJECT-TYPE
Physical Drive force Rebuild operation support Values: notSupported(0), supported(1)
1.3.6.1.4.1.3582.5.1.4.1.1.6.1.4INTEGERread-onlymandatory
vdOperationSupportTable
OBJECT-TYPE
A List operations supported by Virtual Drive
1.3.6.1.4.1.3582.5.1.4.1.1.7not-accessibleoptional
vdOperationSupportEntry
OBJECT-TYPE
An Entry in the vdOperationSupport Table.
1.3.6.1.4.1.3582.5.1.4.1.1.7.1not-accessiblemandatory
vdOpAdpID
OBJECT-TYPE
Unique adapter ID
1.3.6.1.4.1.3582.5.1.4.1.1.7.1.1INTEGERread-onlymandatory
readPolicy
OBJECT-TYPE
Read policy support. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.7.1.2INTEGERread-onlymandatory
writePolicy
OBJECT-TYPE
Write policy support. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.7.1.3INTEGERread-onlymandatory
ioPolicy
OBJECT-TYPE
IO policy support. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.7.1.4INTEGERread-onlymandatory
accessPolicy
OBJECT-TYPE
Access policy support. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.7.1.5INTEGERread-onlymandatory
diskCachePolicy
OBJECT-TYPE
Disk Cache Policy support. Values: False(0), True(1)
1.3.6.1.4.1.3582.5.1.4.1.1.7.1.6INTEGERread-onlymandatory
bbuInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.1.2
bbuNumber
OBJECT-TYPE
The present number of rows in the bbuTable.
1.3.6.1.4.1.3582.5.1.4.1.2.1Gaugeread-onlymandatory
bbuTable
OBJECT-TYPE
A List of bbu Entries containing Information/Properties about the BBU.
1.3.6.1.4.1.3582.5.1.4.1.2.2not-accessibleoptional
bbuEntry
OBJECT-TYPE
An Entry in the BBU table.
1.3.6.1.4.1.3582.5.1.4.1.2.2.1not-accessiblemandatory
bbuID
OBJECT-TYPE
BBUID for this BBU.(Unique)
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.1INTEGERread-onlyoptional
batteryType
OBJECT-TYPE
BBU Type: Values: n/a(0), ibbu(1), bbu(2), zcr_legacy(3), itbbu3(4)
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.2INTEGERread-onlyoptional
nextLearnTime
OBJECT-TYPE
Time of next scheduled lean cycle (seconds path 1/1/2000)
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.3INTEGERread-onlyoptional
absStateOfCharge
OBJECT-TYPE
Predicted remaining capacity expressed as % of DesignCapacity() (0-100). Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.4INTEGER (0..100)read-onlyoptional
fullChargeCapacity
OBJECT-TYPE
Predicted pack capacity when it is fully charged in mAh
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.5INTEGERread-onlyoptional
averageEmptyTime
OBJECT-TYPE
One-minute rolling average of the predicted remaining battery life. Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.6INTEGERread-onlyoptional
cycleCount
OBJECT-TYPE
Number of charge cycles the battery has experienced. Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.7INTEGERread-onlyoptional
firmwareStatus
OBJECT-TYPE
condition of battery in following order: packMissing(0/1) voltageLow(0/1) temperatureHigh(0/1) chargeActive(0/1) dischargeActive(0/1) learnCycleRequested(0/1) learnCycleActive(0/1) learnCycleFailed(0/1) learnCycleTimeout(0/1) i2cErrorsDetected(0/1) Only enabled(1) values will be shown
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.8DisplayStringread-onlyoptional
voltage
OBJECT-TYPE
Accurate battery terminal voltage in mV, resolution of 1mV
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.9INTEGERread-onlyoptional
autoLearnPeriod
OBJECT-TYPE
Time (in seconds) between learn cycles (0 to disable auto learn)
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.10INTEGERread-onlyoptional
relStateOfCharge
OBJECT-TYPE
Predicted remaining capacity expressed as % of FullChargeCapacity() (0-100). Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.11INTEGER (0..100)read-onlyoptional
capacityRemain
OBJECT-TYPE
Predicted charge or energy remaining in the battery in mAh
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.12INTEGERread-onlyoptional
runTimeToEmpty
OBJECT-TYPE
(in minutes)Relative gain or loss in remaining life in response to change in power policy. Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.13INTEGERread-onlyoptional
avgTimeToFull
OBJECT-TYPE
One-minute rolling average of predicted remaining time to full charge. Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.14INTEGERread-onlyoptional
errorMargin
OBJECT-TYPE
Expected margin of error (%) in charge calculation (2-100). Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.15INTEGER (2..100)read-onlyoptional
temperature
OBJECT-TYPE
Battery temperature in degree Centigrade
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.16INTEGERread-onlyoptional
mfgName
OBJECT-TYPE
Battery manufacturer's name
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.17DisplayStringread-onlyoptional
deviceName
OBJECT-TYPE
Battery name
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.18DisplayStringread-onlyoptional
serialNumber
OBJECT-TYPE
Battery serialNumber
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.19DisplayStringread-onlyoptional
chargerStatus
OBJECT-TYPE
Battery charger status. Values: N/A(-1), off(0), complete(1), progress(2)
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.20INTEGERread-onlyoptional
adpID
OBJECT-TYPE
The adapter id where BBU is attached
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.21INTEGERread-onlyoptional
remainingCapAlarm
OBJECT-TYPE
Remaining capacity to alarm. Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.22INTEGERread-onlyoptional
remainingTimeAlarm
OBJECT-TYPE
Remaining time to alarm. Value of -1 means not supported
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.23INTEGERread-onlyoptional
bbu_current
OBJECT-TYPE
Current(In mA) being supplied (or accepted) through the terminals of the battery
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.24INTEGERread-onlyoptional
gasGaugeStatus
OBJECT-TYPE
Gas guage status
1.3.6.1.4.1.3582.5.1.4.1.2.2.1.25INTEGERread-onlyoptional
device
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.2
physicalDriveInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.2.1
pdNumber
OBJECT-TYPE
The present number of rows in the physicalDrive table.
1.3.6.1.4.1.3582.5.1.4.2.1.1Gaugeread-onlymandatory
pdTable
OBJECT-TYPE
A List of physicalDrive Entries containing Information/Properties about the drives
1.3.6.1.4.1.3582.5.1.4.2.1.2not-accessibleoptional
pdEntry
OBJECT-TYPE
An Entry in the Device Table.
1.3.6.1.4.1.3582.5.1.4.2.1.2.1not-accessibleoptional
pdIndex
OBJECT-TYPE
The unique ID
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.1INTEGERread-onlyoptional
physDevID
OBJECT-TYPE
The Device ID
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.2INTEGERread-onlyoptional
oemSupported
OBJECT-TYPE
Drive support by the OEM (OEM-specific checks) Values: notSupported(1), supported(0)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.3INTEGERread-onlyoptional
scsiDevType
OBJECT-TYPE
Type of this Device. Values: disk(0), tape(1), printer(2), processor(3), cdrom(5), scanner(6), optical(7), enclosure(13), dvd(10), unknown(31)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.4INTEGERread-onlyoptional
connectedAdapterPort
OBJECT-TYPE
Adapter port to which the device is connected.
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.5INTEGERread-onlyoptional
deviceSpeed
OBJECT-TYPE
Maximum supported speed. Values: speed_unknown(0), speed_1p5G(1), speed_3G(2),speed_6G(3)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.6INTEGERread-onlyoptional
mediaErrCount
OBJECT-TYPE
Error count of the device
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.7INTEGERread-onlyoptional
otherErrCount
OBJECT-TYPE
other error count of the device
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.8INTEGERread-onlyoptional
predFailCount
OBJECT-TYPE
Predictive fail count of the device
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.9INTEGERread-onlyoptional
pdState
OBJECT-TYPE
Firmware's interpretation of drive state. Values: unconfigured_good(0), unconfigured_bad(1), hot_spare(2), offline(16), failed(17), rebuild(20), online(24),copyback(32),system(64)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.10INTEGERread-onlyoptional
disabledForRemoval
OBJECT-TYPE
If true, drive is ready for removal. Values: false(0), true(1)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.11INTEGERread-onlyoptional
linkSpeed
OBJECT-TYPE
Negotiated link speed. Values: speed_unknown(0), speed_1p5G(1), speed_3G(2), speed_6G(3)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.12INTEGERread-onlyoptional
pdSupportFlags
OBJECT-TYPE
1st Byte:forcedPDGUID(0/1),2nd Byte:inVD(0/1),3rd Byte:isGlobalSpare(0/1),4th Byte:isSpare(0/1),5th Byte:isForeign(0/1),6th Byte:intf(0-Unknown, 1-parallel SCSI, 2-SAS, 3-SATA, 4-FC).A comma delimited list will appear.
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.13DisplayStringread-onlyoptional
pdSasAddr
OBJECT-TYPE
Device SAS addresses. Comma separeted for multiple address
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.14DisplayStringread-onlyoptional
rawSize
OBJECT-TYPE
Size(MB) before COD and coercion
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.15INTEGERread-onlyoptional
nonCoercedSize
OBJECT-TYPE
Size(MB) after COD is reserved but before coercion
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.16INTEGERread-onlyoptional
coercedSize
OBJECT-TYPE
Size(MB) after COD is reserved and after coercion
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.17INTEGERread-onlyoptional
enclDeviceId
OBJECT-TYPE
Enclosure's device Id (in decimal); if device is not within enclosure value is -1
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.18INTEGERread-onlyoptional
enclIndex
OBJECT-TYPE
Firmware internal enclosure index
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.19INTEGERread-onlyoptional
slotNumber
OBJECT-TYPE
Slot number of this drive, if this Physical Drive is an enclosure then -1
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.20INTEGER (0..255)read-onlyoptional
pdOperationProgress
OBJECT-TYPE
% Progress is %. e.g. Rebuild progress is 10%
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.21DisplayStringread-onlyoptional
pdAdpID
OBJECT-TYPE
Controller id where this Physical Drive is attached
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.22INTEGERread-onlyoptional
operationSupport
OBJECT-TYPE
Online,Offline,Failed,Bad,Uncofigured good,Unconfigured bad, Spare,Spare,replaceMissing,markMissing,startRebuild,stopRebuild, locate,stopSecureEraseNonSED,FWDownloadAllowed
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.23DisplayStringread-onlyoptional
vendorID
OBJECT-TYPE
Vendor ID
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.24DisplayStringread-onlyoptional
productID
OBJECT-TYPE
Product ID
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.25DisplayStringread-onlyoptional
pdFwversion
OBJECT-TYPE
Physical drive firmware version
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.26DisplayStringread-onlyoptional
pdSerialNumber
OBJECT-TYPE
Physical drive serial number
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.27DisplayStringread-onlyoptional
diskType
OBJECT-TYPE
Type of the disk : 0-Unknown, 1-parallel SCSI, 2-SAS, 3-SATA, 4-FC
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.28INTEGERread-onlyoptional
partnerDevId
OBJECT-TYPE
If drive is in an enclosure with dual paths,This is Partner Device ID. In all other cases INVALID(-1)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.29INTEGERread-onlyoptional
mediatype
OBJECT-TYPE
Media Type HDD(0),SSD(1)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.30INTEGERread-onlyoptional
oemCertified
OBJECT-TYPE
Indicates whether device is certified(0) or not(1)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.31INTEGERread-onlyoptional
pdTemperature
OBJECT-TYPE
Physical Drive temperature in Celsius
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.32INTEGERread-onlyoptional
piType
OBJECT-TYPE
SAS Protection Information Type .No SAS protection type used(0) ,SAS PI Type 1(1) ,SAS PI Type 2(2) ,SAS PI Type 3(3) ,Reserved SAS PI Type 4(4) ,Reserved SAS PI Type 5(5) ,Reserved SAS PI Type 6(6) ,Reserved SAS PI Type 7(7).
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.33INTEGERread-onlyoptional
userDataBlockSize
OBJECT-TYPE
Number of bytes of user data in LBA
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.34INTEGERread-onlyoptional
cage
OBJECT-TYPE
Current Cage that holds the SSD
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.35INTEGERread-onlyoptional
location
OBJECT-TYPE
Current location of SSD 0 - Upper, 1 - Lower
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.36DisplayStringread-onlyoptional
whtemperature
OBJECT-TYPE
Temperature of each SSD
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.37INTEGERread-onlyoptional
flashType
OBJECT-TYPE
Flash Type being used (SLC / MLC / EMLC)
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.38DisplayStringread-onlyoptional
lifeCurveStatus
OBJECT-TYPE
100 - No throttling being done, 90 - SSD is being throttled
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.39DisplayStringread-onlyoptional
sSDLifeLeft
OBJECT-TYPE
Percentage of SSD life left
1.3.6.1.4.1.3582.5.1.4.2.1.2.1.40DisplayStringread-onlyoptional
virtualDevice
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.3
vdInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.3.1
vdNumber
OBJECT-TYPE
The present number of rows in the virtualDrive table.
1.3.6.1.4.1.3582.5.1.4.3.1.1Gaugeread-onlymandatory
vdTable
OBJECT-TYPE
A List of Virtual Drive Entries containing Information/Properties about the virtualDrive.
1.3.6.1.4.1.3582.5.1.4.3.1.2not-accessibleoptional
vdEntry
OBJECT-TYPE
An Entry in the virtualDrive Table.
1.3.6.1.4.1.3582.5.1.4.3.1.2.1not-accessibleoptional
virtualDevID
OBJECT-TYPE
The unique Virtual Drive ID
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.1INTEGERread-onlyoptional
size
OBJECT-TYPE
Total size in MB of the drive
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.2INTEGERread-onlyoptional
clusterOwnerDeviceId
OBJECT-TYPE
Virtual Drive owner's device Id
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.3INTEGERread-onlyoptional
targetId
OBJECT-TYPE
Virtual Drive target id (i.e. 0 to 63)
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.4INTEGERread-onlyoptional
state
OBJECT-TYPE
Virtual Drive state. Values: offline(0), partially_degraded(1), degraded(2), optimal(3)
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.5INTEGERread-onlyoptional
name
OBJECT-TYPE
Virtual Drive name
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.6DisplayStringread-onlyoptional
defaultCachePolicy
OBJECT-TYPE
Default cache policy settings. Values: direct_io(0), cached_io(1)
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.7INTEGERread-onlyoptional
vdAccessPolicy
OBJECT-TYPE
Access policy settings. Values: access_rw(0), access_read_only(2), access_blocked(3)
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.8INTEGERread-onlyoptional
vdDiskCachePolicy
OBJECT-TYPE
Physical disk cache policy. Values: enable(1), disable(2)
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.9INTEGER (1..2)read-writeoptional
bgiState
OBJECT-TYPE
BGI state on this VD. Values disable(1), enable(0)
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.10INTEGERread-onlyoptional
prl
OBJECT-TYPE
Primay raid level. Values: 0(RAID-0), 1(RAID-1), 3(RAID-3), 4(RAID-4), 5(RAID-5), 6(RAID-6),15(Single Disk or JBOD), 17(RAID-1E/10), 21(RAID-5E), 31(Concatenation),37(RAID-5EEE)
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.11INTEGERread-onlyoptional
rLQ
OBJECT-TYPE
Raid level qualifier
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.12INTEGERread-onlyoptional
sRL
OBJECT-TYPE
Secondary raid level. Values: 0(Stripped), 1(Mirrored), 2(Concatenated), 3(Spanned), -1(Not Supported for IR2)
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.13INTEGERread-onlyoptional
stripeSize
OBJECT-TYPE
Stripe Size. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etc
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.14INTEGERread-onlyoptional
numDrives
OBJECT-TYPE
Number of drivers per span
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.15INTEGERread-onlyoptional
spanDepth
OBJECT-TYPE
Number of spans. If only one array then it is considered as 1 span
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.16INTEGERread-onlyoptional
initState
OBJECT-TYPE
0=no init, 1=quick init, 2=full init
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.17INTEGERread-onlyoptional
currentCachePolicy
OBJECT-TYPE
Default cache policy settings. Values: direct_io(0), cached_io(1)
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.18INTEGERread-onlyoptional
operationProgress
OBJECT-TYPE
Progress % for operation x/ No operation in progress
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.19DisplayStringread-onlyoptional
vdAdpID
OBJECT-TYPE
Controller id where this vd is present
1.3.6.1.4.1.3582.5.1.4.3.1.2.1.20INTEGERread-onlyoptional
vdSpanInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.3.2
vdSpanNumber
OBJECT-TYPE
The present number of rows in the virtualDrive table.
1.3.6.1.4.1.3582.5.1.4.3.2.1Gaugeread-onlymandatory
vdSpanTable
OBJECT-TYPE
A List of span Entries containing Information/Properties vd span.
1.3.6.1.4.1.3582.5.1.4.3.2.2not-accessibleoptional
vdSpanEntry
OBJECT-TYPE
An Entry in the vdSpan Table.
1.3.6.1.4.1.3582.5.1.4.3.2.2.1not-accessibleoptional
spanID
OBJECT-TYPE
The unique Span ID
1.3.6.1.4.1.3582.5.1.4.3.2.2.1.1INTEGERread-onlyoptional
vDevID
OBJECT-TYPE
The Virtual Device ID
1.3.6.1.4.1.3582.5.1.4.3.2.2.1.2INTEGERread-onlyoptional
startBlock
OBJECT-TYPE
Span physical disk starting block
1.3.6.1.4.1.3582.5.1.4.3.2.2.1.3INTEGERread-onlyoptional
numBlocks
OBJECT-TYPE
Span physical disk block count
1.3.6.1.4.1.3582.5.1.4.3.2.2.1.4DisplayStringread-onlyoptional
vdsArrayRef
OBJECT-TYPE
Array reference (index)
1.3.6.1.4.1.3582.5.1.4.3.2.2.1.5INTEGERread-onlyoptional
spAdpId
OBJECT-TYPE
Adapter where the span will be found
1.3.6.1.4.1.3582.5.1.4.3.2.2.1.6INTEGERread-onlyoptional
arrayInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.3.3
arrayNumber
OBJECT-TYPE
The present number of rows in the array table.
1.3.6.1.4.1.3582.5.1.4.3.3.1Gaugeread-onlymandatory
arrayTable
OBJECT-TYPE
A List of array Entries containing Information/Properties about the arrays.
1.3.6.1.4.1.3582.5.1.4.3.3.2not-accessibleoptional
arrayEntry
OBJECT-TYPE
An Entry in the array Table.
1.3.6.1.4.1.3582.5.1.4.3.3.2.1not-accessibleoptional
arrayID
OBJECT-TYPE
The unique array ID
1.3.6.1.4.1.3582.5.1.4.3.3.2.1.1INTEGERread-onlyoptional
arrSize
OBJECT-TYPE
Size in MB
1.3.6.1.4.1.3582.5.1.4.3.3.2.1.2INTEGERread-onlyoptional
arrNumDrives
OBJECT-TYPE
Number of drives for this array
1.3.6.1.4.1.3582.5.1.4.3.3.2.1.3INTEGERread-onlyoptional
arrayRef
OBJECT-TYPE
Tag for the array
1.3.6.1.4.1.3582.5.1.4.3.3.2.1.4INTEGERread-onlyoptional
pdList
OBJECT-TYPE
Space separated pd identification. e.g. {devID devID devID} etc
1.3.6.1.4.1.3582.5.1.4.3.3.2.1.5DisplayStringread-onlyoptional
arrAdpId
OBJECT-TYPE
Adapter where the array will be found
1.3.6.1.4.1.3582.5.1.4.3.3.2.1.6INTEGERread-onlyoptional
spareInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.3.4
spareDevNumber
OBJECT-TYPE
The present number of rows in the sparepool table.
1.3.6.1.4.1.3582.5.1.4.3.4.1Gaugeread-onlymandatory
spareTable
OBJECT-TYPE
A List of sparepool Entries containing Information/Properties about the spare drive
1.3.6.1.4.1.3582.5.1.4.3.4.2not-accessibleoptional
spareEntry
OBJECT-TYPE
An Entry in the sparepool Table.
1.3.6.1.4.1.3582.5.1.4.3.4.2.1not-accessibleoptional
spareID
OBJECT-TYPE
The unique Index
1.3.6.1.4.1.3582.5.1.4.3.4.2.1.1INTEGERread-onlyoptional
deviceIdentification
OBJECT-TYPE
The Device ID
1.3.6.1.4.1.3582.5.1.4.3.4.2.1.2INTEGERread-onlyoptional
spareType
OBJECT-TYPE
Spare type. isDedicated(0/1)isRevertible(0/1)isEnclAffinity(0/1). 1 implies particular feature is enable and 0 represent feature is disable.
1.3.6.1.4.1.3582.5.1.4.3.4.2.1.3DisplayStringread-onlyoptional
arrayCount
OBJECT-TYPE
The number of arrays to which the PD can be dedicated
1.3.6.1.4.1.3582.5.1.4.3.4.2.1.4INTEGERread-onlyoptional
arrRef
OBJECT-TYPE
Comma separated array ids. e.g. 2,4,5 etc
1.3.6.1.4.1.3582.5.1.4.3.4.2.1.5DisplayStringread-onlyoptional
sprAdpId
OBJECT-TYPE
Adapter where the spare will be found
1.3.6.1.4.1.3582.5.1.4.3.4.2.1.6INTEGERread-onlyoptional
enclosure
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.4
enclosureInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.4.1
enclosureNumber
OBJECT-TYPE
The present number of rows in the enclosure table.
1.3.6.1.4.1.3582.5.1.4.4.1.1Gaugeread-onlymandatory
enclosureTable
OBJECT-TYPE
A List of enclosure Entries containing Information/Properties about the enclosures in the system.
1.3.6.1.4.1.3582.5.1.4.4.1.2not-accessibleoptional
enclosureEntry
OBJECT-TYPE
An Entry in the enclosure table.
1.3.6.1.4.1.3582.5.1.4.4.1.2.1not-accessiblemandatory
enclosureID
OBJECT-TYPE
EnclosureID for this enclosure.(Unique)
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.1INTEGERread-onlyoptional
deviceId
OBJECT-TYPE
Enclosure device Id.
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.2INTEGERread-onlyoptional
enclosureIndex
OBJECT-TYPE
Firmware internal enclosure index
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.3INTEGERread-onlyoptional
slotCount
OBJECT-TYPE
Number of slots
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.4INTEGERread-onlyoptional
psCount
OBJECT-TYPE
Number of power supplies
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.5INTEGERread-onlyoptional
fanCount
OBJECT-TYPE
Number of fans
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.6INTEGERread-onlyoptional
tempSensorCount
OBJECT-TYPE
Number of temperature sensors
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.7INTEGERread-onlyoptional
alarmCount
OBJECT-TYPE
Number of alarms
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.8INTEGERread-onlyoptional
simCount
OBJECT-TYPE
Number of SIM modules
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.9INTEGERread-onlyoptional
isFault
OBJECT-TYPE
Enclosure has entered a FAULT state or not. Values: false(0), true(1)
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.10INTEGERread-onlyoptional
pdCount
OBJECT-TYPE
Number of physical drives present
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.11INTEGERread-onlyoptional
pdIds
OBJECT-TYPE
Physical drive deviceId's comma separated.
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.12DisplayStringread-onlyoptional
encAdpID
OBJECT-TYPE
Adapter ID where this enclosure is connected
1.3.6.1.4.1.3582.5.1.4.4.1.2.1.13INTEGERread-onlyoptional
enclosureFanInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.4.2
enclosureFanNumber
OBJECT-TYPE
The present number of rows in the enclosure fan table.
1.3.6.1.4.1.3582.5.1.4.4.2.1Gaugeread-onlymandatory
enclosureFanTable
OBJECT-TYPE
A List of fan Entries containing Information/Properties about the enclosureFan.
1.3.6.1.4.1.3582.5.1.4.4.2.2not-accessibleoptional
enclosureFanEntry
OBJECT-TYPE
An Entry in the enclosureFan table.
1.3.6.1.4.1.3582.5.1.4.4.2.2.1not-accessiblemandatory
fanID
OBJECT-TYPE
ID for this enclosureFan.(Unique)
1.3.6.1.4.1.3582.5.1.4.4.2.2.1.1INTEGERread-onlyoptional
enclosureId
OBJECT-TYPE
Enclosure ID where the fan is attached
1.3.6.1.4.1.3582.5.1.4.4.2.2.1.2INTEGERread-onlyoptional
fanStatus
OBJECT-TYPE
status of the device
1.3.6.1.4.1.3582.5.1.4.4.2.2.1.3INTEGER {status-ok(1), status-critical(2), status-nonCritical(3), status-unrecoverable(4), status-not-installed(5), status-unknown(6), status-not-available(7)}read-onlyoptional
enclosureSlotInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.4.3
enclosureSlotNum
OBJECT-TYPE
The present number of rows in the enclosure slot table.
1.3.6.1.4.1.3582.5.1.4.4.3.1Gaugeread-onlymandatory
enclosureSlotTable
OBJECT-TYPE
A List of slot Entries containing Information/Properties about the enclosure slots.
1.3.6.1.4.1.3582.5.1.4.4.3.2not-accessibleoptional
enclosureSlotEntry
OBJECT-TYPE
An Entry in the enclosureSlot table.
1.3.6.1.4.1.3582.5.1.4.4.3.2.1not-accessiblemandatory
slotID
OBJECT-TYPE
ID for this slot.(Unique)
1.3.6.1.4.1.3582.5.1.4.4.3.2.1.1INTEGERread-onlyoptional
sltEncId
OBJECT-TYPE
Enclosure ID where the slot
1.3.6.1.4.1.3582.5.1.4.4.3.2.1.2INTEGERread-onlyoptional
slotStatus
OBJECT-TYPE
status of the device. Values: status-ok(1), status-critical(2), status-nonCritical(3), status-unrecoverable(4), status-not-installed(5), status-unknown(6), status-not-available(7)
1.3.6.1.4.1.3582.5.1.4.4.3.2.1.3INTEGER {status-ok(1), status-critical(2), status-nonCritical(3), status-unrecoverable(4), status-not-installed(5), status-unknown(6), status-not-available(7)}read-onlyoptional
enclosurePSInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.4.4
enclosurePSNumber
OBJECT-TYPE
The present number of rows in the enclosure fan table.
1.3.6.1.4.1.3582.5.1.4.4.4.1Gaugeread-onlymandatory
enclosurePSTable
OBJECT-TYPE
A List of powerSupply Entries containing Information/Properties about the enclosure powerSupply
1.3.6.1.4.1.3582.5.1.4.4.4.2not-accessibleoptional
enclosurePSEntry
OBJECT-TYPE
An Entry in the powerSupply table.
1.3.6.1.4.1.3582.5.1.4.4.4.2.1not-accessiblemandatory
powerSupplyID
OBJECT-TYPE
ID for this powerSupply.(Unique)
1.3.6.1.4.1.3582.5.1.4.4.4.2.1.1INTEGERread-onlyoptional
psEnclosureId
OBJECT-TYPE
Enclosure id for the powerSupply
1.3.6.1.4.1.3582.5.1.4.4.4.2.1.2INTEGERread-onlyoptional
powerSupplyStatus
OBJECT-TYPE
status of the power Supply
1.3.6.1.4.1.3582.5.1.4.4.4.2.1.3INTEGER {status-ok(1), status-critical(2), status-nonCritical(3), status-unrecoverable(4), status-not-installed(5), status-unknown(6), status-not-available(7)}read-onlyoptional
enclosureTSInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.4.5
enclosureTSNumber
OBJECT-TYPE
The present number of rows in the enclosure fan table.
1.3.6.1.4.1.3582.5.1.4.4.5.1Gaugeread-onlymandatory
enclosureTSTable
OBJECT-TYPE
A List of TempSensor Entries containing Information/Properties about the enclosure TempSensor
1.3.6.1.4.1.3582.5.1.4.4.5.2not-accessibleoptional
enclosureTSEntry
OBJECT-TYPE
An Entry in the adapter table.
1.3.6.1.4.1.3582.5.1.4.4.5.2.1not-accessiblemandatory
tempSensorID
OBJECT-TYPE
ID for this TempSensor.(Unique)
1.3.6.1.4.1.3582.5.1.4.4.5.2.1.1INTEGERread-onlyoptional
encId
OBJECT-TYPE
enclosure id for this TempSensor
1.3.6.1.4.1.3582.5.1.4.4.5.2.1.2INTEGERread-onlyoptional
tempSensorStatus
OBJECT-TYPE
status of this tempSensor
1.3.6.1.4.1.3582.5.1.4.4.5.2.1.3INTEGER {status-ok(1), status-critical(2), status-nonCritical(3), status-unrecoverable(4), status-not-installed(5), status-unknown(6), status-not-available(7)}read-onlyoptional
tsTemperature
OBJECT-TYPE
Current temperature in degree Centigrade
1.3.6.1.4.1.3582.5.1.4.4.5.2.1.4INTEGERread-onlyoptional
enclosureAlarmInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.4.6
enclosureAlarmNumber
OBJECT-TYPE
The present number of rows in the enclosure fan table.
1.3.6.1.4.1.3582.5.1.4.4.6.1Gaugeread-onlymandatory
enclosureAlarmTable
OBJECT-TYPE
A List of Alarm Entries containing Information/Properties about enclosure Alarms
1.3.6.1.4.1.3582.5.1.4.4.6.2not-accessibleoptional
enclosureAlarmEntry
OBJECT-TYPE
An Entry in the enclosureAlarm table.
1.3.6.1.4.1.3582.5.1.4.4.6.2.1not-accessiblemandatory
alarmID
OBJECT-TYPE
ID for this Alarm.(Unique)
1.3.6.1.4.1.3582.5.1.4.4.6.2.1.1INTEGERread-onlyoptional
almEnclosureId
OBJECT-TYPE
Enclosure id where the Alarm is attached
1.3.6.1.4.1.3582.5.1.4.4.6.2.1.2INTEGERread-onlyoptional
alarmStatus
OBJECT-TYPE
Status of the alarm
1.3.6.1.4.1.3582.5.1.4.4.6.2.1.3INTEGER {status-ok(1), status-critical(2), status-nonCritical(3), status-unrecoverable(4), status-not-installed(5), status-unknown(6), status-not-available(7)}read-onlyoptional
enclosureSIMInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.4.7
enclosureSIMNumber
OBJECT-TYPE
The present number of rows in the enclosure fan table.
1.3.6.1.4.1.3582.5.1.4.4.7.1Gaugeread-onlymandatory
enclosureSIMTable
OBJECT-TYPE
A List of SIM Entries containing Information/Properties about enclosure SIMs
1.3.6.1.4.1.3582.5.1.4.4.7.2not-accessibleoptional
enclosureSIMEntry
OBJECT-TYPE
An Entry in the enclosureSIM table.
1.3.6.1.4.1.3582.5.1.4.4.7.2.1not-accessiblemandatory
simID
OBJECT-TYPE
ID for this SIM.(Unique)
1.3.6.1.4.1.3582.5.1.4.4.7.2.1.1INTEGERread-onlyoptional
simEnclosureId
OBJECT-TYPE
Enclosure id where the SIM is attached
1.3.6.1.4.1.3582.5.1.4.4.7.2.1.2INTEGERread-onlyoptional
simStatus
OBJECT-TYPE
Number of Logical Drives Configured on this Adapter.
1.3.6.1.4.1.3582.5.1.4.4.7.2.1.3INTEGER {status-ok(1), status-critical(2), status-nonCritical(3), status-unrecoverable(4), status-not-installed(5), status-unknown(6), status-not-available(7)}read-onlyoptional
topology
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.5
phyInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.5.1
phyNumber
OBJECT-TYPE
The present number of rows in the Phy table.
1.3.6.1.4.1.3582.5.1.4.5.1.1Gaugeread-onlymandatory
phyTable
OBJECT-TYPE
A List of phy Entries containing Information/Properties about the sas topology in the system.
1.3.6.1.4.1.3582.5.1.4.5.1.2not-accessibleoptional
phyEntry
OBJECT-TYPE
An Entry in the Phy table.
1.3.6.1.4.1.3582.5.1.4.5.1.2.1not-accessiblemandatory
phyIndex
OBJECT-TYPE
Index for this phy.(Unique)
1.3.6.1.4.1.3582.5.1.4.5.1.2.1.1INTEGERread-onlyoptional
deviceIndex
OBJECT-TYPE
Index of the device in tDeviceTable where the phy is attached
1.3.6.1.4.1.3582.5.1.4.5.1.2.1.2INTEGERread-onlyoptional
deviceType
OBJECT-TYPE
Type of device attached to this phy NO_DEVICE = 0, IOC(1), EDGE_EXPANDER(2), FANOUT_EXPANDER(3),END_DEVICE(4)
1.3.6.1.4.1.3582.5.1.4.5.1.2.1.3INTEGERread-onlyoptional
phyID
OBJECT-TYPE
The phy ID of the attached device
1.3.6.1.4.1.3582.5.1.4.5.1.2.1.4INTEGERread-onlyoptional
deviceOffset
OBJECT-TYPE
The memory offset where the node of the device that is attached to this phy starts.
1.3.6.1.4.1.3582.5.1.4.5.1.2.1.5INTEGERread-onlyoptional
phyPos
OBJECT-TYPE
Position of the Phy in device attached.
1.3.6.1.4.1.3582.5.1.4.5.1.2.1.6INTEGERread-onlyoptional
devicesInTopology
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.5.2
tDeviceNumber
OBJECT-TYPE
The present number of rows in the topology Device table.
1.3.6.1.4.1.3582.5.1.4.5.2.1Gaugeread-onlymandatory
tDeviceTable
OBJECT-TYPE
A List of device Entries containing Information/Properties about the sas topology in the system.
1.3.6.1.4.1.3582.5.1.4.5.2.2not-accessibleoptional
tDeviceEntry
OBJECT-TYPE
An Entry in the tDevice table.
1.3.6.1.4.1.3582.5.1.4.5.2.2.1not-accessiblemandatory
tDeviceIndex
OBJECT-TYPE
Index for this device.(Unique)
1.3.6.1.4.1.3582.5.1.4.5.2.2.1.1INTEGERread-onlyoptional
contID
OBJECT-TYPE
Adapter ID where this device is attached
1.3.6.1.4.1.3582.5.1.4.5.2.2.1.2INTEGERread-onlyoptional
tDeviceId
OBJECT-TYPE
Device ID.
1.3.6.1.4.1.3582.5.1.4.5.2.2.1.3INTEGERread-onlyoptional
tDeviceType
OBJECT-TYPE
NO_DEVICE = 0, IOC(1), EDGE_EXPANDER(2), FANOUT_EXPANDER(3),END_DEVICE(4)
1.3.6.1.4.1.3582.5.1.4.5.2.2.1.4INTEGERread-onlyoptional
tParentIndex
OBJECT-TYPE
Index of the parent device in the table where this device is connected. -1 if it root device.
1.3.6.1.4.1.3582.5.1.4.5.2.2.1.5INTEGERread-onlyoptional
tNumPhy
OBJECT-TYPE
Total no of Phy present in this device
1.3.6.1.4.1.3582.5.1.4.5.2.2.1.6INTEGERread-onlyoptional
tSASAddr
OBJECT-TYPE
Device SAS addresses. Comma separeted for multiple address
1.3.6.1.4.1.3582.5.1.4.5.2.2.1.7DisplayStringread-onlyoptional
tDevDescription
OBJECT-TYPE
Detailed description of the Device.
1.3.6.1.4.1.3582.5.1.4.5.2.2.1.8DisplayStringread-onlyoptional
lsi_SAS_Traps
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.4.6
atAdpNumber
OBJECT-TYPE
Adapter ID for which Trap is generated.
1.3.6.1.4.1.3582.5.1.4.6.1001INTEGERread-onlyoptional
atAlarmState
OBJECT-TYPE
Alarm disabled(0)/enabled(1)
1.3.6.1.4.1.3582.5.1.4.6.1002INTEGERread-onlyoptional
atRate
OBJECT-TYPE
BGI/Check Consistency/Rebuild/Patrol Read/Reconstruction Rate
1.3.6.1.4.1.3582.5.1.4.6.1003INTEGERread-onlyoptional
atFlashImageName
OBJECT-TYPE
Flash Image Name
1.3.6.1.4.1.3582.5.1.4.6.1004DisplayStringread-onlyoptional
atSensorNum
OBJECT-TYPE
Sensor Number
1.3.6.1.4.1.3582.5.1.4.6.1005INTEGERread-onlyoptional
atThreshold
OBJECT-TYPE
Threshold
1.3.6.1.4.1.3582.5.1.4.6.1006INTEGERread-onlyoptional
atTemperature
OBJECT-TYPE
Temperature Exceeded
1.3.6.1.4.1.3582.5.1.4.6.1007INTEGERread-onlyoptional
devLife
OBJECT-TYPE
Drive Life
1.3.6.1.4.1.3582.5.1.4.6.1008INTEGERread-onlyoptional
atWarningLevel
OBJECT-TYPE
Warning Level
1.3.6.1.4.1.3582.5.1.4.6.1009INTEGERread-onlyoptional
atErrorLevel
OBJECT-TYPE
Error Level
1.3.6.1.4.1.3582.5.1.4.6.1010INTEGERread-onlyoptional
Throttle
OBJECT-TYPE
Throttle
1.3.6.1.4.1.3582.5.1.4.6.1011INTEGERread-onlyoptional
PercentThrottle
OBJECT-TYPE
Percent Throttle
1.3.6.1.4.1.3582.5.1.4.6.1012INTEGERread-onlyoptional
PCISlotAvailPower
OBJECT-TYPE
PCI Slot Avail Power
1.3.6.1.4.1.3582.5.1.4.6.1013INTEGERread-onlyoptional
Flags
OBJECT-TYPE
Flags SENSOR(1)|SLOT(2)
1.3.6.1.4.1.3582.5.1.4.6.1014INTEGERread-onlyoptional
SensorOrSlot
OBJECT-TYPE
Sensor Or Slot depending on the value of thr Flag
1.3.6.1.4.1.3582.5.1.4.6.1015INTEGERread-onlyoptional
CurrTemp
OBJECT-TYPE
Current Temp
1.3.6.1.4.1.3582.5.1.4.6.1016INTEGERread-onlyoptional
ThresholdTemp
OBJECT-TYPE
Threshold Temp
1.3.6.1.4.1.3582.5.1.4.6.1017INTEGERread-onlyoptional
vdNum
OBJECT-TYPE
Virtual Drive Target ID for which Trap is generated.
1.3.6.1.4.1.3582.5.1.4.6.1101INTEGERread-onlyoptional
vdSeq
OBJECT-TYPE
Virtual Drive Sequence no for which Trap is generated.
1.3.6.1.4.1.3582.5.1.4.6.1102INTEGERread-onlyoptional
vdProg
OBJECT-TYPE
progress %
1.3.6.1.4.1.3582.5.1.4.6.1103INTEGERread-onlyoptional
vdCachePolicyChangeReason
OBJECT-TYPE
Virtual Drive cache policy.
1.3.6.1.4.1.3582.5.1.4.6.1104DisplayStringread-onlyoptional
vdNewState
OBJECT-TYPE
Virtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3)
1.3.6.1.4.1.3582.5.1.4.6.1105INTEGERread-onlyoptional
vdOldState
OBJECT-TYPE
Virtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3)
1.3.6.1.4.1.3582.5.1.4.6.1106INTEGERread-onlyoptional
pdID
OBJECT-TYPE
Device ID for which Trap is generated.
1.3.6.1.4.1.3582.5.1.4.6.1201INTEGERread-onlyoptional
pdEncIndex
OBJECT-TYPE
Enclosure index(0 means not within an enclosure) for which Trap is generated.
1.3.6.1.4.1.3582.5.1.4.6.1202INTEGERread-onlyoptional
pdSlotNo
OBJECT-TYPE
Slot no for the enclosure
1.3.6.1.4.1.3582.5.1.4.6.1203INTEGERread-onlyoptional
pdNewState
OBJECT-TYPE
Physical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64)
1.3.6.1.4.1.3582.5.1.4.6.1204INTEGERread-onlyoptional
pdOldState
OBJECT-TYPE
Physical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64)
1.3.6.1.4.1.3582.5.1.4.6.1205INTEGERread-onlyoptional
pdCDBData
OBJECT-TYPE
CDB Data.
1.3.6.1.4.1.3582.5.1.4.6.1206DisplayStringread-onlyoptional
pdSenseData
OBJECT-TYPE
Sence Data.
1.3.6.1.4.1.3582.5.1.4.6.1207DisplayStringread-onlyoptional
copyrightInfo
OBJECT-IDENTITY
1.3.6.1.4.1.3582.5.1.8

Notifications

NameOIDStatus
irAdpAlarmStateEnabled
NOTIFICATION-TYPE
Alarm has been enabled by user for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7001
irAdpBGIRateChanged
NOTIFICATION-TYPE
Background initialization rate changed to $1 for Adapter $2
1.3.6.1.4.1.3582.5.1.4.6.0.7002
irAdpCacheDiscarded
NOTIFICATION-TYPE
Controller $1 cache discarded due to memory/battery problems
1.3.6.1.4.1.3582.5.1.4.6.0.7003
irAdpCacheRebootCantRecover
NOTIFICATION-TYPE
Unable to recover cache data due to configuration mismatch for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7004
irAdpCacheRebootRecover
NOTIFICATION-TYPE
Cache data recovered successfully for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7005
irAdpCacheVersionMismatch
NOTIFICATION-TYPE
Controller cache discarded due to firmware version incompatibility for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7006
irAdpCCRateChanged
NOTIFICATION-TYPE
Consistency Check rate changed to $1 for Adapter $2
1.3.6.1.4.1.3582.5.1.4.6.0.7007
irAdpFlashBadImage
NOTIFICATION-TYPE
Flash downloaded image corrupted for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7008
irAdpFlashEraseError
NOTIFICATION-TYPE
Flash erase error for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7009
irAdpFlashEraseTimeout
NOTIFICATION-TYPE
Flash timeout during erase for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7010
irAdpFlashGeneralError
NOTIFICATION-TYPE
Flash error for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7011
irAdpFlashImage
NOTIFICATION-TYPE
Flashing image: $1 for Adapter $2
1.3.6.1.4.1.3582.5.1.4.6.0.7012
irAdpFlashOK
NOTIFICATION-TYPE
Flash of new firmware image(s)complete for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7013
irAdpFlashProgramError
NOTIFICATION-TYPE
Flash programming error for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7014
irAdpFlashProgramTimeout
NOTIFICATION-TYPE
Flash timeout during programming for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7015
irAdpLogCleared
NOTIFICATION-TYPE
Event log cleared for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7016
irAdpLogWrapped
NOTIFICATION-TYPE
Event log wrapped for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7017
irAdpPatrolReadComplete
NOTIFICATION-TYPE
Patrol Read complete for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7018
irAdpPatrolReadPaused
NOTIFICATION-TYPE
Patrol Read paused for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7019
irAdpPatrolReadResumed
NOTIFICATION-TYPE
Patrol Read resumed for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7020
irAdpPatrolReadStarted
NOTIFICATION-TYPE
Patrol Read started for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7021
irAdpShutdown
NOTIFICATION-TYPE
Shutdown command received for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7022
irAdpHibernate
NOTIFICATION-TYPE
Hibernate command received for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7023
irAdpCrash
NOTIFICATION-TYPE
Fatal error received for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7024
irAdpRRChanged
NOTIFICATION-TYPE
Rebuild rate changed to $1 for Adapter $2
1.3.6.1.4.1.3582.5.1.4.6.0.7025
irAdpPRRateChanged
NOTIFICATION-TYPE
Patrol Read rate changed to $1 for Adapter $2
1.3.6.1.4.1.3582.5.1.4.6.0.7026
irAdpAlarmStateDisabled
NOTIFICATION-TYPE
Alarm has been disabled by user for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7027
irAdpConfigCleared
NOTIFICATION-TYPE
Configuration cleared for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7028
irAdpReconRateChanged
NOTIFICATION-TYPE
Reconstruction rate changed to $1 for Adapter $2
1.3.6.1.4.1.3582.5.1.4.6.0.7029
irAdpDefault
NOTIFICATION-TYPE
Factory defaults restored for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7030
irAdpThresholdsExceededCritical
NOTIFICATION-TYPE
Adapter $1 on sensor $2 has exceeded critical temperature threshold $3 Temperature $4
1.3.6.1.4.1.3582.5.1.4.6.0.7031
irAdpThresholdsExceededWarning
NOTIFICATION-TYPE
Adapter $1 on sensor $2 has exceeded warning temperature threshold $3 Temperature $4
1.3.6.1.4.1.3582.5.1.4.6.0.7032
irAdpBRMFailed
NOTIFICATION-TYPE
Backup Rail Monitor has failed for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7033
irAdpSSDLifeExhausted
NOTIFICATION-TYPE
Adapter $1 SSD Life for SlotNo $2 PD ID $3 Dev Life $4 Warning Level $5 Error Level $6
1.3.6.1.4.1.3582.5.1.4.6.0.7034
irAdpSSDLifeWarning
NOTIFICATION-TYPE
Adapter $1 SSD Life for SlotNo $2 PD ID $3 Dev Life $4 Warning Level $5 Error Level $6
1.3.6.1.4.1.3582.5.1.4.6.0.7035
irAdpSSDThrottlingRemoved
NOTIFICATION-TYPE
Throttling Removed for Adapter $1 PD Slot No $2 Dev ID $3 Throttle $4
1.3.6.1.4.1.3582.5.1.4.6.0.7036
irAdpSSDThrottlingOccuring
NOTIFICATION-TYPE
Throttling Occuring for Adapter $1 PD Slot No $2 Dev ID $3 Throttle $4
1.3.6.1.4.1.3582.5.1.4.6.0.7037
irAdpPowerThrottlingRemoved
NOTIFICATION-TYPE
Power Throttling is Removed for Adapter $1 Percent Throttle $2 PCISlotAvailPower $3
1.3.6.1.4.1.3582.5.1.4.6.0.7038
irAdpPowerThrottlingOccuring
NOTIFICATION-TYPE
Power Throttling is Occuring for Adapter $1 Percent Throttle $2 PCISlotAvailPower $3
1.3.6.1.4.1.3582.5.1.4.6.0.7039
irAdpDFFTempExceededWarning
NOTIFICATION-TYPE
Adapter $1 Flags $2 SensorOrSlot $3 CurrTemp $4 ThresholdTemp $5 pdID $6
1.3.6.1.4.1.3582.5.1.4.6.0.7040
irAdpDFFTempExceededCritical
NOTIFICATION-TYPE
Adapter $1 Flags $2 SensorOrSlot $3 CurrTemp $4 ThresholdTemp $5 pdID $6
1.3.6.1.4.1.3582.5.1.4.6.0.7041
irVdtBGIAborted
NOTIFICATION-TYPE
BGI aborted on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7101
irVdtBGICompleted
NOTIFICATION-TYPE
BGI completed on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7102
irVdtBGIDoneWR
NOTIFICATION-TYPE
BGI completed with uncorrectable errors on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7103
irVdtBGIFailed
NOTIFICATION-TYPE
BGI failed on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7104
irVdtBGIStarted
NOTIFICATION-TYPE
BGI started on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7105
irVdtCCStarted
NOTIFICATION-TYPE
CC started on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7107
irVdtCCCompleted
NOTIFICATION-TYPE
CC completed on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7108
irVdtCCFailed
NOTIFICATION-TYPE
CC failed on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7109
irVdtCCAborted
NOTIFICATION-TYPE
CC aborted on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7110
irVdtCCCompCor
NOTIFICATION-TYPE
CC completed with correction on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7111
irVdtInitAborted
NOTIFICATION-TYPE
Initialization aborted on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7112
irVdtInitFailed
NOTIFICATION-TYPE
Initialization failed on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7113
irVdtInitCompleted
NOTIFICATION-TYPE
Initialization completed on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7114
irVdtInitFastStarted
NOTIFICATION-TYPE
Fast Initialization started on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7115
irVdtInitFullStarted
NOTIFICATION-TYPE
Full Initialization started on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7116
irVdtReconStarted
NOTIFICATION-TYPE
Reconstructoin started on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7117
irVdtReconCompleted
NOTIFICATION-TYPE
Reconstruction completed on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7118
irVdtReconResumed
NOTIFICATION-TYPE
Reconstruction resumed on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7119
irVdtReconStopped
NOTIFICATION-TYPE
Reconstruction stopped on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7120
irVdtStateChange
NOTIFICATION-TYPE
VD state changed on Adapter -$1 VD Target -$2 from $3 to $4
1.3.6.1.4.1.3582.5.1.4.6.0.7121
irVdtCreated
NOTIFICATION-TYPE
A new VD created on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7122
irVdtDeleted
NOTIFICATION-TYPE
A VD deleted on Adapter -$1 VD Target -$2
1.3.6.1.4.1.3582.5.1.4.6.0.7123
irPdtClearAborted
NOTIFICATION-TYPE
PD Clear aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7201
irPdtClearFailed
NOTIFICATION-TYPE
PD Clear failed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7202
irPdtClearStarted
NOTIFICATION-TYPE
PD Clear started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7203
irPdtClearCompleted
NOTIFICATION-TYPE
PD Clear completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7204
irPdtError
NOTIFICATION-TYPE
Error occurred on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7205
irPdtFormatStart
NOTIFICATION-TYPE
PD format started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7206
irPdtFormatCompleted
NOTIFICATION-TYPE
PD format completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7207
irPdtInserted
NOTIFICATION-TYPE
PD inserted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7208
irPdtRblAborted
NOTIFICATION-TYPE
Rebuild aborted on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7209
irPdtRblCompleted
NOTIFICATION-TYPE
Rebuild completed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7210
irPdtRblFailedBS
NOTIFICATION-TYPE
Rebuild failed(bad source) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7211
irPdtRblFailedBT
NOTIFICATION-TYPE
Rebuild failed(bad target) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7212
irPdtRblStart
NOTIFICATION-TYPE
Rebuild started on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7213
irPdtRblResumed
NOTIFICATION-TYPE
Rebuild resumed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7214
irPdtRblStartA
NOTIFICATION-TYPE
Rebuild started(auto) on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7215
irPdtRemoved
NOTIFICATION-TYPE
PD removed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7216
irPdtStateChange
NOTIFICATION-TYPE
PD state changed on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 from $5 to $6
1.3.6.1.4.1.3582.5.1.4.6.0.7217
irPdtSENSEAlert
NOTIFICATION-TYPE
An unexpected Sense was detected on Adapter -$1 Dev -$2 Enc -$3 Slot -$4 CDBData -$5 SenseData -$6
1.3.6.1.4.1.3582.5.1.4.6.0.7218
irPdtPredictiveThresholdExceed
NOTIFICATION-TYPE
Predictive Threshold Exceeded on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7219
irPdSSDSecurityLocked
NOTIFICATION-TYPE
SSD is in locked state on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7220
irPdSSDSecurityUnlocked
NOTIFICATION-TYPE
SSD is in unlocked state on Adapter -$1 Dev -$2 Enc -$3 Slot -$4
1.3.6.1.4.1.3582.5.1.4.6.0.7221
irBbuPresent
NOTIFICATION-TYPE
Battery Present for Adapter %d
1.3.6.1.4.1.3582.5.1.4.6.0.7301
irBbuNotPresent
NOTIFICATION-TYPE
Battery Not Present for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7302
irBbuNewBattery
NOTIFICATION-TYPE
New Battery for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7303
irBbuReplaced
NOTIFICATION-TYPE
Battery replaced for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7304
irBbuTempHigh
NOTIFICATION-TYPE
Battery temperature high for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7305
irBbuVoltageLow
NOTIFICATION-TYPE
Battery voltage low for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7306
irBbuCharging
NOTIFICATION-TYPE
Battery started charging for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7307
irBbuDisCharging
NOTIFICATION-TYPE
Battery is discharging for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7308
irBbuTempNormal
NOTIFICATION-TYPE
Battery temperature is normal for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7309
irBbuReplace
NOTIFICATION-TYPE
Battery needs replacement, SOH Bad for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7310
irBbuRelearnStarted
NOTIFICATION-TYPE
Battery relearn started for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7311
irBbuRelearnProgress
NOTIFICATION-TYPE
Battery relearn in progress for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7312
irBbuRelearnComplete
NOTIFICATION-TYPE
Battery relearn completed for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7313
irBbuRelearnTimeout
NOTIFICATION-TYPE
Battery relearn timed out for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7314
irBbuRelearnPending
NOTIFICATION-TYPE
Battery relearn pending: Battery is under charge for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7315
irBbuRelearnPostponed
NOTIFICATION-TYPE
Battery relearn postponed for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7316
irBbuRemoved
NOTIFICATION-TYPE
Battery removed for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7317
irBbuCapacityLow
NOTIFICATION-TYPE
Current capacity of the battery is below threshold for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7318
irBbuCapacityAbove
NOTIFICATION-TYPE
Current capacity of the battery is above threshold for Adapter $1
1.3.6.1.4.1.3582.5.1.4.6.0.7319