MIBs Depot

LINKSYS-PHY-MIB

Registered at
1.3.6.1.4.1.3955.1000.201.90
Last updated
2002-09-30 00:24
Organization
Linksys Computer Communication Ltd.
Revisions
2002-09-30 00:24, 2003-09-21 00:24
Namespace
linksys
Source file
LINKSYS-PHY-MIB
Digest
sha256:6e1fb4a4922c23726188a4cd6c383aa40356e3e728da0f2cd5ff96ec72ea5b3b

Description

The MIB module describes the private MIB for testing Layer1 interfaces supported by Linksys's software and products.

Contact

www.linksys.com/business/support

Imports

FromSymbols
IF-MIBifIndex
LINKSYS-MIBrnd
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TimeStamp

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
LINKSYS-MIB
LINKSYS-PHY-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
RlPhyTestType
TEXTUAL-CONVENTION
A value indicating the test to perform.
current

Objects

NameOIDSyntaxAccessStatus
rlPhyTest
OBJECT-IDENTITY
1.3.6.1.4.1.3955.1000.201.90.1
rlPhyTestSetTable
OBJECT-TYPE
1.3.6.1.4.1.3955.1000.201.90.1.1not-accessiblecurrent
rlPhyTestSetEntry
OBJECT-TYPE
An entry containing objects for invoking tests on an interface.
1.3.6.1.4.1.3955.1000.201.90.1.1.1not-accessiblecurrent
rlPhyTestSetType
OBJECT-TYPE
A control variable used to start operator initiated interface tests.1 indicates that no test has been initiated. Only operator initiated interface tests can be set to this variable.
1.3.6.1.4.1.3955.1000.201.90.1.1.1.1RlPhyTestTyperead-writecurrent
rlPhyTestGetTable
OBJECT-TYPE
1.3.6.1.4.1.3955.1000.201.90.1.2not-accessiblecurrent
rlPhyTestGetEntry
OBJECT-TYPE
An entry containing results of tests on an interface.
1.3.6.1.4.1.3955.1000.201.90.1.2.1not-accessiblecurrent
rlPhyTestGetType
OBJECT-TYPE
A control variable used to, 1 to indicate that this test can be done on the specified port, 2 to initiate the test whenever the user wishes
1.3.6.1.4.1.3955.1000.201.90.1.2.1.1RlPhyTestTyperead-onlycurrent
rlPhyTestGetStatus
OBJECT-TYPE
This object contains the status of the most recently requested test for operator initiated tests or the value none(1) if no tests have been requested since the last reset. For non operator initiated tests the value is always none(1). Note that this facility provides no provision for saving the results of one test when starting another, as could be required if used by multiple managers concurrently.
1.3.6.1.4.1.3955.1000.201.90.1.2.1.2INTEGER {none(1), success(2), inProgress(3), notSupported(4), unAbleToRun(5), aborted(6), failed(7)}read-onlycurrent
rlPhyTestGetResult
OBJECT-TYPE
This object holds the test result
1.3.6.1.4.1.3955.1000.201.90.1.2.1.3INTEGERread-onlycurrent
rlPhyTestGetUnits
OBJECT-TYPE
The test result unit of measure. The units can be standard unit or special units that are designed for special test. The alaskaPhyLength unit is design for the VCT diagnostic and its values are: less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5). The alaskaPhyStatus unit is design for the VCT diagnostic and its values are: 4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7).
1.3.6.1.4.1.3955.1000.201.90.1.2.1.4INTEGER {integer(1), boolean(2), downUP(3), reverseNormal(4), mdiMdix(5), meter(6), degree(7), microVolt(8), microOham(9), microAmper(10), microWatt(11), millisecond(12), alaskaPhyLength(13), alaskaPhyStatus(14), dbm(15), decidbm(16), milidbm(17), abcd(18), nanosecond(19)}read-onlycurrent
rlPhyTestGetAlarm
OBJECT-TYPE
This object hold the Alarm for this Entry. only Test that have can have alarms use this field, other holds the Value notRelevant(1)
1.3.6.1.4.1.3955.1000.201.90.1.2.1.5INTEGER {notRelevant(1), noAlarmSet(2), lowWarning(3), highWarning(4), lowAlarm(5), highAlarm(6)}read-onlycurrent
rlPhyTestGetTimeStamp
OBJECT-TYPE
The time in string (formated DD-MMM-YYYY HH:MM:SS e.g 14-Apr-2002 10:33:31)
1.3.6.1.4.1.3955.1000.201.90.1.2.1.6DisplayString (SIZE(1..32))read-onlycurrent