LINKSYS-PHY-MIB
- Registered at
- 1.3.6.1.4.1.3955.1000.201.90
- Last updated
- 2002-09-30 00:24
- Organization
- Linksys Computer Communication Ltd.
- Revisions
- 2002-09-30 00:24, 2003-09-21 00:24
- Namespace
- linksys
- Source file
LINKSYS-PHY-MIB- Digest
sha256:6e1fb4a4922c23726188a4cd6c383aa40356e3e728da0f2cd5ff96ec72ea5b3b
Description
The MIB module describes the private MIB for testing Layer1 interfaces supported by Linksys's software and products.
Contact
www.linksys.com/business/support
Imports
| From | Symbols |
|---|---|
| IF-MIB | ifIndex |
| LINKSYS-MIB | rnd |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION, TimeStamp |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB IF-MIB LINKSYS-MIB LINKSYS-PHY-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| RlPhyTestType TEXTUAL-CONVENTION A value indicating the test to perform. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| rlPhyTest OBJECT-IDENTITY | 1.3.6.1.4.1.3955.1000.201.90.1 | |||
| rlPhyTestSetTable OBJECT-TYPE | 1.3.6.1.4.1.3955.1000.201.90.1.1 | not-accessible | current | |
| rlPhyTestSetEntry OBJECT-TYPE An entry containing objects for invoking tests on an interface. | 1.3.6.1.4.1.3955.1000.201.90.1.1.1 | not-accessible | current | |
| rlPhyTestSetType OBJECT-TYPE A control variable used to start operator initiated interface tests.1 indicates that no test has been initiated. Only operator initiated interface tests can be set to this variable. | 1.3.6.1.4.1.3955.1000.201.90.1.1.1.1 | RlPhyTestType | read-write | current |
| rlPhyTestGetTable OBJECT-TYPE | 1.3.6.1.4.1.3955.1000.201.90.1.2 | not-accessible | current | |
| rlPhyTestGetEntry OBJECT-TYPE An entry containing results of tests on an interface. | 1.3.6.1.4.1.3955.1000.201.90.1.2.1 | not-accessible | current | |
| rlPhyTestGetType OBJECT-TYPE A control variable used to, 1 to indicate that this test can be done on the specified port, 2 to initiate the test whenever the user wishes | 1.3.6.1.4.1.3955.1000.201.90.1.2.1.1 | RlPhyTestType | read-only | current |
| rlPhyTestGetStatus OBJECT-TYPE This object contains the status of the most recently requested test for operator initiated tests or the value none(1) if no tests have been requested since the last reset. For non operator initiated tests the value is always none(1). Note that this facility provides no provision for saving the results of one test when starting another, as could be required if used by multiple managers concurrently. | 1.3.6.1.4.1.3955.1000.201.90.1.2.1.2 | INTEGER {none(1), success(2), inProgress(3), notSupported(4), unAbleToRun(5), aborted(6), failed(7)} | read-only | current |
| rlPhyTestGetResult OBJECT-TYPE This object holds the test result | 1.3.6.1.4.1.3955.1000.201.90.1.2.1.3 | INTEGER | read-only | current |
| rlPhyTestGetUnits OBJECT-TYPE The test result unit of measure. The units can be standard unit or special units that are designed for special test. The alaskaPhyLength unit is design for the VCT diagnostic and its values are: less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5). The alaskaPhyStatus unit is design for the VCT diagnostic and its values are: 4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7). | 1.3.6.1.4.1.3955.1000.201.90.1.2.1.4 | INTEGER {integer(1), boolean(2), downUP(3), reverseNormal(4), mdiMdix(5), meter(6), degree(7), microVolt(8), microOham(9), microAmper(10), microWatt(11), millisecond(12), alaskaPhyLength(13), alaskaPhyStatus(14), dbm(15), decidbm(16), milidbm(17), abcd(18), nanosecond(19)} | read-only | current |
| rlPhyTestGetAlarm OBJECT-TYPE This object hold the Alarm for this Entry. only Test that have can have alarms use this field, other holds the Value notRelevant(1) | 1.3.6.1.4.1.3955.1000.201.90.1.2.1.5 | INTEGER {notRelevant(1), noAlarmSet(2), lowWarning(3), highWarning(4), lowAlarm(5), highAlarm(6)} | read-only | current |
| rlPhyTestGetTimeStamp OBJECT-TYPE The time in string (formated DD-MMM-YYYY HH:MM:SS e.g 14-Apr-2002 10:33:31) | 1.3.6.1.4.1.3955.1000.201.90.1.2.1.6 | DisplayString (SIZE(1..32)) | read-only | current |