LINKSYS-EMBWEB-MIB- Digest
sha256:b6d712004f71df458d062d8b8ea02e71d102b81eead6ff92b689193a0af0b8f1
Description
This private MIB module adds MIBs to EMBWEB (Embedded Web Server).
Contact
www.linksys.com/business/support
Imports
| From | Symbols |
|---|---|
| LINKSYS-MIB | rnd |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, RowStatus, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
LINKSYS-EMBWEB-MIB LINKSYS-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| RlEmbWebEnabled TEXTUAL-CONVENTION Embedde Web Service Support Enabled/Disabled | current | |||
| RlEmbWebProtocol TEXTUAL-CONVENTION Embedde Web Protocol | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| rlEmWebMibVersion OBJECT-TYPE Embedded web version, the current version is 2. | 1.3.6.1.4.1.3955.1000.201.66.1 | INTEGER | read-only | current |
| rlEmWebWebSite OBJECT-TYPE Link for the vendor web site used to retrive information. | 1.3.6.1.4.1.3955.1000.201.66.2 | DisplayString | read-write | current |
| rlEmWebSecurityTable OBJECT-TYPE Security Table whose entry is composed of username and Password, group and access privileges for each user. The access privileges can be one or more of none, read-files, read-write, and super. | 1.3.6.1.4.1.3955.1000.201.66.3 | not-accessible | current | |
| rlEmWebSecurityEntry OBJECT-TYPE The row definition for this table. | 1.3.6.1.4.1.3955.1000.201.66.3.1 | not-accessible | current | |
| rlEmWebSecurityUserName OBJECT-TYPE The User name. | 1.3.6.1.4.1.3955.1000.201.66.3.1.1 | DisplayString (SIZE(1..16)) | read-write | current |
| rlEmWebSecurityPassword OBJECT-TYPE The User password. | 1.3.6.1.4.1.3955.1000.201.66.3.1.2 | DisplayString (SIZE(1..16)) | read-write | current |
| rlEmWebSecurityAccess OBJECT-TYPE Access rights for this user . | 1.3.6.1.4.1.3955.1000.201.66.3.1.3 | INTEGER {none(1), readOnly(2), readWrite(3), super(4)} | read-write | current |
| rlEmWebSecurityIpAddr OBJECT-TYPE IP Address to send the traps to.0 means doesn't want to receive traps. | 1.3.6.1.4.1.3955.1000.201.66.3.1.4 | IpAddress | read-write | current |
| rlEmWebSecurityPort OBJECT-TYPE Port to send the traps to. | 1.3.6.1.4.1.3955.1000.201.66.3.1.5 | INTEGER | read-write | current |
| rlEmWebSecuritySnmpVersion OBJECT-TYPE SNMP version supported by this user. For the agent use. | 1.3.6.1.4.1.3955.1000.201.66.3.1.6 | INTEGER {ver1(1), ver2(2), ver3(3)} | read-write | current |
| rlEmWebSecurityStatus OBJECT-TYPE The status of the security table entry. It's used to delete an entry | 1.3.6.1.4.1.3955.1000.201.66.3.1.7 | RowStatus | read-write | current |
| rlEmWebCloseTimeout OBJECT-TYPE This variable defines the maximum time period in seconds that a TCP connection can stay open without depending on the TCP timeout mechanism | 1.3.6.1.4.1.3955.1000.201.66.5 | INTEGER (1..255) | read-write | current |
| rlEmWebReceiveTimeout OBJECT-TYPE This variable defines the maximum time period in seconds that a TCP connection can wait for data which hasn't arrived | 1.3.6.1.4.1.3955.1000.201.66.6 | INTEGER (1..255) | read-write | current |
| rlEmWebMaxIdleTimeout OBJECT-TYPE This variable defines the maximum HTTP Idle time period in seconds for a TCP connection.If another request isn't made at this period, the connection is closed. The value 0 is supported as 'no timeout'. | 1.3.6.1.4.1.3955.1000.201.66.7 | INTEGER (0..3932159) | read-write | current |
| rlEmWebSetEWSfilesStatus OBJECT-TYPE This variable sets the status of the embedded Web Server files to either closed or opened. | 1.3.6.1.4.1.3955.1000.201.66.8 | INTEGER {opened(1), closed(2)} | read-write | current |
| rlEmbeddedWebApplied OBJECT-TYPE Specifies if the device supports Embedded WEB: true - suppotrs false - does not support | 1.3.6.1.4.1.3955.1000.201.66.9 | TruthValue | read-only | current |
| rlEmWebHttpPort OBJECT-TYPE Specifies the TCP port the embedded web uses for HTTP sessions. | 1.3.6.1.4.1.3955.1000.201.66.10 | INTEGER (0..65535) | read-write | current |
| rlEmWebHttpEnable OBJECT-TYPE Enable/Disable HTTP sessions | 1.3.6.1.4.1.3955.1000.201.66.11 | TruthValue | read-write | current |
| rlEmWebHttpsPort OBJECT-TYPE Specifies the TCP port the embedded web uses for HTTPS sessions. | 1.3.6.1.4.1.3955.1000.201.66.12 | INTEGER (0..65535) | read-write | current |
| rlEmWebHttpsEnable OBJECT-TYPE Enable/Disable HTTPS sessions | 1.3.6.1.4.1.3955.1000.201.66.13 | TruthValue | read-write | current |
| rlEmWebCertificateCountryName OBJECT-TYPE Value of country name field that will appear when a new certificate is generated. | 1.3.6.1.4.1.3955.1000.201.66.14 | DisplayString (SIZE(2)) | read-write | current |
| rlEmWebCertificateStateOrProvinceName OBJECT-TYPE Value of state or province name field that will appear when a new certificate is generated. | 1.3.6.1.4.1.3955.1000.201.66.15 | DisplayString (SIZE(1..128)) | read-write | current |
| rlEmWebCertificateLocalityName OBJECT-TYPE Value of locality field that will appear when a new certificate is generated. | 1.3.6.1.4.1.3955.1000.201.66.16 | DisplayString (SIZE(1..64)) | read-write | current |
| rlEmWebCertificateOrganizationName OBJECT-TYPE Value of organization field that will appear when a new certificate is generated. | 1.3.6.1.4.1.3955.1000.201.66.17 | DisplayString (SIZE(1..64)) | read-write | current |
| rlEmWebCertificateCommonName OBJECT-TYPE Value of common name field that will appear when a new certificate is generated. | 1.3.6.1.4.1.3955.1000.201.66.19 | IpAddress | read-write | current |
| rlEmWebCertificateRegenerate OBJECT-TYPE Setting to a regenerateCertificate causes a new certifiacte to be generated and to be used for all new sessions. | 1.3.6.1.4.1.3955.1000.201.66.20 | INTEGER {noAction(0), regenerateCertificate(1), regenerateRsaKeyAndCertificate(2)} | read-write | current |
| rlEmWebRsaKeyLength OBJECT-TYPE Setting the RSA key size that will be created when rlEmWebRegenerateCertificateAndKey will be set to regenerateCertificateAndKey. | 1.3.6.1.4.1.3955.1000.201.66.21 | INTEGER (512..2048) | read-write | current |
| rlEmWebDebug OBJECT-TYPE MIB variable for setting debug information. | 1.3.6.1.4.1.3955.1000.201.66.22 | INTEGER | read-write | current |
| rlEmWebURL OBJECT-TYPE The URL through which the EWS of this device can be accessed. | 1.3.6.1.4.1.3955.1000.201.66.23 | DisplayString | read-only | current |
| rlEmWebDisplayNonPresentEntities OBJECT-TYPE This object indicates whether the EWS is required to display non-present entities (like non-present ports, IP addresses on non-present ports etc.) on it's screens. | 1.3.6.1.4.1.3955.1000.201.66.24 | TruthValue | read-only | current |
| rlEmWebCertificateExists OBJECT-TYPE This object indicates whether a certificate has been generated. | 1.3.6.1.4.1.3955.1000.201.66.25 | TruthValue | read-only | current |
| rlEmWebHttpsActiveCertificateId OBJECT-TYPE By setting this scalar https is notified that the certificate and key with this index should be used for new https sessions. Even if the certifcate or key doesn't exist yet the operation will succeed. | 1.3.6.1.4.1.3955.1000.201.66.26 | INTEGER | read-write | current |
| rlEmWebExtraPort OBJECT-TYPE Specifies the TCP port the embedded web uses for The Extra Port sessions. | 1.3.6.1.4.1.3955.1000.201.66.27 | INTEGER (0..65535) | read-write | current |
| rlEmWebExtraPortType OBJECT-TYPE Specifies the Extra Port Type HTTP/HTTPS for all sessions. | 1.3.6.1.4.1.3955.1000.201.66.28 | INTEGER {http(0), https(1)} | read-write | current |
| rlEmWebMaxHttpsIdleTimeout OBJECT-TYPE This variable defines the maximum HTTPS Idle time period in seconds for a web connection.If another request isn't made at this period, the connection is closed. The value 0 is supported as 'no timeout'. | 1.3.6.1.4.1.3955.1000.201.66.29 | INTEGER (0..3932159) | read-write | current |
| rlEmWebServiceTable OBJECT-TYPE . | 1.3.6.1.4.1.3955.1000.201.66.30 | not-accessible | current | |
| rlEmWebServiceEntry OBJECT-TYPE The row definition for this table. | 1.3.6.1.4.1.3955.1000.201.66.30.1 | not-accessible | current | |
| rlEmWebServiceId OBJECT-TYPE The Service Id. | 1.3.6.1.4.1.3955.1000.201.66.30.1.1 | INTEGER | not-accessible | current |
| rlEmWebServiceName OBJECT-TYPE Service name | 1.3.6.1.4.1.3955.1000.201.66.30.1.2 | DisplayString (SIZE(1..16)) | read-only | current |
| rlEmWebServiceEnable OBJECT-TYPE Indicates whether the service is enabled or not. if set to 'default' will the service to go back to its initialization default status. | 1.3.6.1.4.1.3955.1000.201.66.30.1.3 | RlEmbWebEnabled | read-write | current |
| rlEmWebServicePort OBJECT-TYPE Indicates whether the TCP port on which service is listening. value 0 will set the service to it's default port | 1.3.6.1.4.1.3955.1000.201.66.30.1.4 | INTEGER (0..65535) | read-write | current |
| rlEmWebServiceMaxUsers OBJECT-TYPE The maximal number of users for this service. | 1.3.6.1.4.1.3955.1000.201.66.30.1.5 | INTEGER | read-only | current |
| rlEmWebServiceProtocol OBJECT-TYPE Indicates the protocol that the service operates on. Note that the general HTTP service can have only the http value and the general HTTPS service can have only the https value. setting the field to 'default' will cause the service to go back to it's initialization settings. | 1.3.6.1.4.1.3955.1000.201.66.30.1.6 | RlEmbWebProtocol | read-write | current |
| rlEmWebServiceCertificateId OBJECT-TYPE Indicates the certificate used by the service if rlEmWebServiceProtocol is https. A value of 0 indicates that a certificate has not been assigned to this service. setting this field to 1000 will cause the service to go back to it's initialization value. | 1.3.6.1.4.1.3955.1000.201.66.30.1.7 | INTEGER | read-write | current |
| rlEmWebServiceMaxIdleTimeOut OBJECT-TYPE This variable defines the maximum Idle time period in seconds for a TCP connection. If another request isn't made at this period, the connection is closed. The value 0 is supported as 'no timeout'.setting this field to 3932160 will cause the service to go back to it's initialization value. | 1.3.6.1.4.1.3955.1000.201.66.30.1.8 | INTEGER (0..3932160) | read-write | current |