MIBs Depot

LIGHTSTREAM-MIB

Registered at
1.3.6.1.4.1.711
Namespace
cisco
Source file
LIGHTSTREAM-MIB
Digest
sha256:c59a9ba59d2ed9744dcae79988ac89e0a10723d7d66bc34f421f45530aaf72f7

Imports

FromSymbols
IF-MIBifIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMICounter32, Gauge32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, TimeTicks, enterprises, iso, mib-2
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
LIGHTSTREAM-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
LightStreamDLCI
type
LightStreamFilterAction
type
LightStreamStatus
type
LightStreamUpToMaxAge
type
LightStreamValidation
type
VCI
type

Objects

NameOIDSyntaxAccessStatus
lightStream
OBJECT-IDENTITY
1.3.6.1.4.1.711
lightStreamOIDs
OBJECT-IDENTITY
1.3.6.1.4.1.711.1
lightStreamATM
OBJECT-IDENTITY
1.3.6.1.4.1.711.1.1
lsOther
OBJECT-IDENTITY
1.3.6.1.4.1.711.1.2
lsTrapNumber
OBJECT-IDENTITY
1.3.6.1.4.1.711.1.2.1
lsTrapText
OBJECT-IDENTITY
1.3.6.1.4.1.711.1.2.2
lsTrapName
OBJECT-IDENTITY
1.3.6.1.4.1.711.1.2.3
lsConfig
OBJECT-IDENTITY
1.3.6.1.4.1.711.1.3
lightStreamProducts
OBJECT-IDENTITY
1.3.6.1.4.1.711.2
atmSwitch
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1
chassisInfo
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.1
chassisId
OBJECT-TYPE
Chassis ID (24 bits)
1.3.6.1.4.1.711.2.1.1.2INTEGERread-onlymandatory
chassisActiveIpAddr
OBJECT-TYPE
Active IP Address for Management of this chassis. This is the IP address used for network mangement and will point to the active of the 2 NPs in a given chassis.
1.3.6.1.4.1.711.2.1.1.3IpAddressread-writemandatory
chassisSecondaryIpAddr
OBJECT-TYPE
Secondary IP Address for Management of this chassis. This is the IP address used for network mangement and will point to the backup NP in a given chassis.
1.3.6.1.4.1.711.2.1.1.4IpAddressread-writemandatory
chassisNetworkMask
OBJECT-TYPE
Subnet mask used for the IP addresses associated with switch ports
1.3.6.1.4.1.711.2.1.1.5IpAddressread-writemandatory
chassisEthernetIpAddr
OBJECT-TYPE
This is the IP Address associated with the ethernet port on the primary NP in the chassis. The Ethernet port on the backup NP is unused,should that NP become primary it will take over the chassisEthernetIpAddr.
1.3.6.1.4.1.711.2.1.1.6IpAddressread-writemandatory
chassisEthernetIpMask
OBJECT-TYPE
This is the IP network mask associated with the Ethernet to which the network processors in the chassis are connected.
1.3.6.1.4.1.711.2.1.1.7IpAddressread-writemandatory
chassisDefaultIpRouter
OBJECT-TYPE
This is a machine, connected to the same ethernet as the chassis' NPs, which is capable of routing IP datagrams to other portions of the Internet.
1.3.6.1.4.1.711.2.1.1.8IpAddressread-writemandatory
chassisStatusWord
OBJECT-TYPE
Bit map of certain chassis wide status information for use with UB Net/Director.
1.3.6.1.4.1.711.2.1.1.9INTEGERread-onlymandatory
chassisConsoleTrapLevel
OBJECT-TYPE
Trap level to use with console trap display
1.3.6.1.4.1.711.2.1.1.10INTEGER {operational(1), informational(2), trace(3), debug(4), off(5)}read-onlymandatory
cardInfo
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.2
cardTable
OBJECT-TYPE
Card specific information
1.3.6.1.4.1.711.2.1.2.1not-accessiblemandatory
cardEntry
OBJECT-TYPE
An entry in the chassis card table. (1-n)
1.3.6.1.4.1.711.2.1.2.1.1not-accessiblemandatory
cardIndex
OBJECT-TYPE
Unique Index consisting of card number.
1.3.6.1.4.1.711.2.1.2.1.1.1INTEGERread-onlymandatory
cardName
OBJECT-TYPE
Name of Card
1.3.6.1.4.1.711.2.1.2.1.1.2DisplayString (SIZE(0..255))read-writemandatory
cardBoardType
OBJECT-TYPE
Board type of this card.
1.3.6.1.4.1.711.2.1.2.1.1.3DisplayString (SIZE(0..255))read-onlymandatory
cardLcSoftwareVersion
OBJECT-TYPE
Software revision of process running in the line card
1.3.6.1.4.1.711.2.1.2.1.1.4DisplayString (SIZE(0..255))read-onlymandatory
cardLccSoftwareVersion
OBJECT-TYPE
Software revision of process controlling card
1.3.6.1.4.1.711.2.1.2.1.1.5DisplayString (SIZE(0..255))read-onlymandatory
cardPID
OBJECT-TYPE
Unique Process ID for LCC process (from OS).
1.3.6.1.4.1.711.2.1.2.1.1.6INTEGERread-onlymandatory
cardMaxVCs
OBJECT-TYPE
Maximum Virtual Circuits Supported by this card
1.3.6.1.4.1.711.2.1.2.1.1.7INTEGERread-writemandatory
cardOperStatus
OBJECT-TYPE
Card Operational status
1.3.6.1.4.1.711.2.1.2.1.1.8INTEGER {up(1), down(2), testing(3), empty(4)}read-onlymandatory
cardAdminStatus
OBJECT-TYPE
Administratively Desired Status of this card
1.3.6.1.4.1.711.2.1.2.1.1.9INTEGER {up(1), down(2), testing(3)}read-writemandatory
cardStatusWord
OBJECT-TYPE
Card status word, for use with the UB Net/Director product
1.3.6.1.4.1.711.2.1.2.1.1.10INTEGERread-onlymandatory
cardConfigRegister
OBJECT-TYPE
Actual Card Enable Status as read from status register
1.3.6.1.4.1.711.2.1.2.1.1.11INTEGER {up(1), down(2), testing(3), empty(4)}read-onlymandatory
portInfo
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.3
portInfoTable
OBJECT-TYPE
Port specific information
1.3.6.1.4.1.711.2.1.3.1not-accessiblemandatory
portInfoEntry
OBJECT-TYPE
An entry in the Edge Port table.
1.3.6.1.4.1.711.2.1.3.1.1not-accessiblemandatory
portInfoIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.3.1.1.1INTEGERread-onlymandatory
portInfoType
OBJECT-TYPE
Object id of the port information table used with this port. (e.g. ls1InfoTable for the low speed line card version 1
1.3.6.1.4.1.711.2.1.3.1.1.2INTEGER {empty(1), error(2), unknown(3), switch(4), np(5), lsEdge(6), lsTrunk(7), msTrunk(8), msEdge(10), plc12fac1(11), plc18eac1(12), plc1Lstoken(13), plc18sac1Edge(14), plc18sac1Trunk(15), clc1Gen(30), clc12oc3ac1Edge(31), clc12oc3ac1Trunk(32), clc18t3ac1Edge(33), clc18t3ac1Trunk(34), clc12taxiac1Edge(35), clc12taxiac1Trunk(36), clc18t1e1cbrac1(37)}read-onlymandatory
portInfoSpecific
OBJECT-TYPE
Object id of the port information table used with this port. (e.g. ls1InfoTable for the low speed line card version 1
1.3.6.1.4.1.711.2.1.3.1.1.3OBJECT IDENTIFIERread-onlymandatory
portInfoName
OBJECT-TYPE
The name of this port. This is primary used as a help aid to identification. There is no absolute need for it to be set.
1.3.6.1.4.1.711.2.1.3.1.1.4DisplayStringread-writemandatory
portInfoErrorLimit
OBJECT-TYPE
The maximum error for this port, expressed as an inverse power of ten. I.E. 3 sets an acceptable error rate of 10**-3 receive+transmit errors. When this object is set to the value 0, the error limit trap is disabled. This value is always 0, i.e. disabled for Ethernet and FDDI ports.
1.3.6.1.4.1.711.2.1.3.1.1.5INTEGERread-writemandatory
portTransmission
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.4
ls1InfoTable
OBJECT-TYPE
Edge Port Address table specific Information
1.3.6.1.4.1.711.2.1.4.1not-accessiblemandatory
ls1InfoEntry
OBJECT-TYPE
An entry in the Edge Port Address table.
1.3.6.1.4.1.711.2.1.4.1.1not-accessiblemandatory
ls1InfoIfIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.4.1.1.1INTEGERread-onlymandatory
ls1InfoType
OBJECT-TYPE
Level 1 interface type used for this port
1.3.6.1.4.1.711.2.1.4.1.1.2INTEGER {v35(1), rs422(2), rs530(3), t1(4), unknown(99)}read-onlymandatory
ls1InfoOperCsuType
OBJECT-TYPE
Identifier of operational CSU Interface
1.3.6.1.4.1.711.2.1.4.1.1.3INTEGER {none(1), larse(2)}read-onlymandatory
ls1InfoAdminCsuType
OBJECT-TYPE
Identifier of administartively specified CSU Interface
1.3.6.1.4.1.711.2.1.4.1.1.4INTEGER {none(1), larse(2)}read-writemandatory
ls1InfoOperRcvBaudRate
OBJECT-TYPE
Operation receive baud rate
1.3.6.1.4.1.711.2.1.4.1.1.5INTEGERread-onlymandatory
ls1InfoAdminRcvBaudRate
OBJECT-TYPE
Adminsitratively desired receive baud rate
1.3.6.1.4.1.711.2.1.4.1.1.6INTEGERread-writemandatory
ls1InfoOperXmitBaudRate
OBJECT-TYPE
Operation transmit baud rate.
1.3.6.1.4.1.711.2.1.4.1.1.7INTEGERread-onlymandatory
ls1InfoAdminXmitBaudRate
OBJECT-TYPE
Admistratively desired transmission baud rate
1.3.6.1.4.1.711.2.1.4.1.1.8INTEGERread-writemandatory
ls1InfoOperNetIntType
OBJECT-TYPE
Operational network Interface Type for this port: DCE, DTE, or DCE with local tt loopback. This last option provides the ability to interface to DTE devices which are unable to return the tt signal as required for full V.35 standard compliance.
1.3.6.1.4.1.711.2.1.4.1.1.9INTEGER {dce(1), dte(2), dceTTloop(3)}read-onlymandatory
ls1InfoAdminNetIntType
OBJECT-TYPE
Administrative or desired Network Interface Type for DCE, DTE, or DCE with local tt loopback. This last option provides the ability to interface to DTE devices which are unable to return the tt signal as required for full V.35 standard compliance.
1.3.6.1.4.1.711.2.1.4.1.1.10INTEGER {dce(1), dte(2), dceTTloop(3)}read-writemandatory
ls1InfoOperModemState
OBJECT-TYPE
Operational Status of certain modem signals. A bitmask which gives the current state of certain modmem signals is returned. If the Port is configured as a DTE, bit 0 will be DCD and bit 1 DSR. If the Port is configured as a DCE, bit 0 will be RTS and bit 1 DTR.
1.3.6.1.4.1.711.2.1.4.1.1.13INTEGERread-onlymandatory
ls1InfoOperProtocol
OBJECT-TYPE
Operational higher level protocol stack to support on this port.
1.3.6.1.4.1.711.2.1.4.1.1.15INTEGER {trunk(1), frameRelay(2), frameForwarding(3), ppp(4), unknown(5)}read-onlymandatory
ls1InfoAdminProtocol
OBJECT-TYPE
Administratively desired higher level protocol stack to support on this port.
1.3.6.1.4.1.711.2.1.4.1.1.16INTEGER {trunk(1), frameRelay(2), frameForwarding(3), ppp(4), unknown(5)}read-writemandatory
ls1InfoOperControlBandwidthSize
OBJECT-TYPE
The current operation value of the control bandwidth size for this port. This is a scaling factor. This value is multiplied by ls1InfoOperRcvBaudRate and the result divided by 1000 to derive the actual bandwidth.
1.3.6.1.4.1.711.2.1.4.1.1.21INTEGERread-onlymandatory
ls1InfoAdminControlBandwidthSize
OBJECT-TYPE
The current administratively desired value of the control bandwidth size for this port. Setting the trigger variable ls1InfoAdimOperTrigger will cause this value to become the operation value. This is a scaling factor. This value is multiplied by ls1InfoAdminRcvBaudRate and the result divided by 1000 to derive the actual bandwidth.
1.3.6.1.4.1.711.2.1.4.1.1.22INTEGERread-writemandatory
ls1InfoOperDataBandwidthSize
OBJECT-TYPE
The current operation value of the data bandwidth size for this port. This is a scaling factor. This value is multiplied by ls1InfoOperRcvBaudRate and the result divided by 1000 to derive the actual bandwidth.
1.3.6.1.4.1.711.2.1.4.1.1.23INTEGERread-onlymandatory
ls1InfoAdminDataBandwidthSize
OBJECT-TYPE
The current administratively desired value of the data bandwidth size for this port. Setting the trigger variable ls1InfoAdimOperTrigger will cause this value to become the operation value. This is a scaling factor. This value is multiplied by ls1InfoAdminRcvBaudRate and the result divided by 1000 to derive the actual bandwidth.
1.3.6.1.4.1.711.2.1.4.1.1.24INTEGERread-writemandatory
ls1InfoOperLoopMode
OBJECT-TYPE
Operational loop mode for this port: none, internal, external, or remote
1.3.6.1.4.1.711.2.1.4.1.1.25INTEGER {none(1), internal(2), external(3), remote(4)}read-onlymandatory
ls1InfoAdminLoopMode
OBJECT-TYPE
Administrative or desired loop mode for this port: none, internal, external, or remote
1.3.6.1.4.1.711.2.1.4.1.1.26INTEGER {none(1), internal(2), external(3), remote(4)}read-writemandatory
ls1InfoLcAutoEnable
OBJECT-TYPE
State of the LC auto-enable flag for this port. If enabled the port will be enable at LC boot time. If disabled the port will remain disabled until configured and started by the LCC software on the NP. This parameter is set in the LC EEPROM by portctl.
1.3.6.1.4.1.711.2.1.4.1.1.27INTEGER {enabled(1), disabled(2)}read-onlymandatory
ls1InfoLcDebugLevel
OBJECT-TYPE
Value of the LC debug level variable for this port. This parameter is set in the LC EEPROM by portctl.
1.3.6.1.4.1.711.2.1.4.1.1.28INTEGERread-onlymandatory
ls1InfoDataCellCapacity
OBJECT-TYPE
The portion of this port's capacity in cells that is allocated for data traffic.
1.3.6.1.4.1.711.2.1.4.1.1.29INTEGERread-onlymandatory
ls1InfoDataCellAvailable
OBJECT-TYPE
The portion of this port's capacity in cells that is available for data traffic. This variable is adjusted for the bandwidth consumed by VCs created using this port. It does not count VCs which have been configured but not yet established.
1.3.6.1.4.1.711.2.1.4.1.1.30INTEGERread-onlymandatory
ls1InfoMeasuredBaudRate
OBJECT-TYPE
This is the line rate as measured from the line card.
1.3.6.1.4.1.711.2.1.4.1.1.31INTEGERread-onlymandatory
ls1InfoLinkUtilization
OBJECT-TYPE
This is an estimated utilization on the link.
1.3.6.1.4.1.711.2.1.4.1.1.32INTEGERread-onlymandatory
ls1InfoAdminOperTrigger
OBJECT-TYPE
When proper commands written to this variable the LCC attempts to change the state of the port such that the oper status reflects the desired admin status.
1.3.6.1.4.1.711.2.1.4.1.1.99INTEGER {trigger(1), other(99)}read-writemandatory
ms1InfoTable
OBJECT-TYPE
Edge Port Address table specific Information
1.3.6.1.4.1.711.2.1.4.2not-accessiblemandatory
ms1InfoEntry
OBJECT-TYPE
An entry in the Edge Port Address table.
1.3.6.1.4.1.711.2.1.4.2.1not-accessiblemandatory
ms1InfoIfIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.4.2.1.1INTEGERread-onlymandatory
ms1InfoOperCableLength
OBJECT-TYPE
Operational value for Cable Length used for this port.
1.3.6.1.4.1.711.2.1.4.2.1.2INTEGER {t3CableLength1(1), t3CableLength2(2), e3CableLength1(3), e3CableLength2(4), e3CableLength3(5), e3CableLength4(6)}read-onlymandatory
ms1InfoAdminCableLength
OBJECT-TYPE
Administrative value for Cable Length used for this port. Setting the trigger variable ms1InfoAdimOperTrigger will cause this value to become the operation value.
1.3.6.1.4.1.711.2.1.4.2.1.3INTEGER {t3CableLength1(1), t3CableLength2(2), e3CableLength1(3), e3CableLength2(4), e3CableLength3(5), e3CableLength4(6)}read-writemandatory
ms1InfoOperProtocol
OBJECT-TYPE
Operational higher level protocol stack to support on this port.
1.3.6.1.4.1.711.2.1.4.2.1.4INTEGER {trunk(1), atmUni(2), unknown(3)}read-onlymandatory
ms1InfoAdminProtocol
OBJECT-TYPE
Administratively desired higher level protocol stack to support on this port.
1.3.6.1.4.1.711.2.1.4.2.1.5INTEGER {trunk(1), atmUni(2), unknown(3)}read-writemandatory
ms1InfoOperControlBandwidthSize
OBJECT-TYPE
The current operation value of the control bandwidth size for this port. This is a scaling factor. This value is multiplied by ms1InfoOperRcvBaudRate and the result divided by 1000 to derive the actual bandwidth.
1.3.6.1.4.1.711.2.1.4.2.1.10INTEGERread-onlymandatory
ms1InfoAdminControlBandwidthSize
OBJECT-TYPE
The current administratively desired value of the control bandwidth size for this port. Setting the trigger variable ms1InfoAdimOperTrigger will cause this value to become the operation value. This is a scaling factor. This value is multiplied by ms1InfoAdminRcvBaudRate and the result divided by 1000 to derive the actual bandwidth.
1.3.6.1.4.1.711.2.1.4.2.1.11INTEGERread-writemandatory
ms1InfoOperDataBandwidthSize
OBJECT-TYPE
The current operation value of the data bandwidth size for this port. This is a scaling factor. This value is multiplied by ms1InfoOperRcvBaudRate and the result divided by 1000 to derive the actual bandwidth.
1.3.6.1.4.1.711.2.1.4.2.1.12INTEGERread-onlymandatory
ms1InfoAdminDataBandwidthSize
OBJECT-TYPE
The current administratively desired value of the data bandwidth size for this port. Setting the trigger variable ms1InfoAdimOperTrigger will cause this value to become the operation value. This is a scaling factor. This value is multiplied by ms1InfoAdminRcvBaudRate and the result divided by 1000 to derive the actual bandwidth.
1.3.6.1.4.1.711.2.1.4.2.1.13INTEGERread-writemandatory
ms1InfoLcAutoEnable
OBJECT-TYPE
State of the LC auto-enable flag for this port. If enabled the port will be enable at LC boot time. If disabled the port will remain disabled until configured and started by the LCC software on the NP. This parameter is set in the LC EEPROM by portctl.
1.3.6.1.4.1.711.2.1.4.2.1.14INTEGER {enabled(1), disabled(2)}read-onlymandatory
ms1InfoLcDebugLevel
OBJECT-TYPE
Value of the LC debug level variable for this port. This parameter is set in the LC EEPROM by portctl.
1.3.6.1.4.1.711.2.1.4.2.1.15INTEGERread-onlymandatory
ms1InfoOperScramble
OBJECT-TYPE
Operational value for Cell Payload scrambling used for this port.
1.3.6.1.4.1.711.2.1.4.2.1.16INTEGER {t3ScrambleEnable(1), t3ScrambleDisable(2)}read-onlymandatory
ms1InfoAdminScramble
OBJECT-TYPE
Administrative value for Cell Payload scrambling used for this port. Setting the trigger variable ms1InfoAdimOperTrigger will cause this value to become the operation value.
1.3.6.1.4.1.711.2.1.4.2.1.17INTEGER {t3ScrambleEnable(1), t3ScrambleDisable(2)}read-writemandatory
ms1InfoDataCellCapacity
OBJECT-TYPE
The portion of this port's capacity in cells that is allocated for data traffic.
1.3.6.1.4.1.711.2.1.4.2.1.18INTEGERread-onlymandatory
ms1InfoDataCellAvailable
OBJECT-TYPE
The portion of this port's capacity in cells that is available for data traffic. This variable is adjusted for the bandwidth consumed by VCs created using this port. It does not count VCs which have been configured but not yet established.
1.3.6.1.4.1.711.2.1.4.2.1.19INTEGERread-onlymandatory
ms1InfoLinkUtilization
OBJECT-TYPE
This is an estimated utilization on the link.
1.3.6.1.4.1.711.2.1.4.2.1.20INTEGERread-onlymandatory
ms1InfoOperFraming
OBJECT-TYPE
Operational ATM framing typein use on this port.
1.3.6.1.4.1.711.2.1.4.2.1.21INTEGER {plcp(1), t3-Hec(2), g-804(3)}read-onlymandatory
ms1InfoAdminOperTrigger
OBJECT-TYPE
When proper commands written to this variable the LCC attempts to change the state of the port such that the oper status reflects the desired admin status.
1.3.6.1.4.1.711.2.1.4.2.1.99INTEGER {trigger(1), other(99)}read-writemandatory
npInfoTable
OBJECT-TYPE
Edge Port Address table specific Information
1.3.6.1.4.1.711.2.1.4.3not-accessiblemandatory
npInfoEntry
OBJECT-TYPE
An entry in the NP configuration table.
1.3.6.1.4.1.711.2.1.4.3.1not-accessiblemandatory
npInfoIfIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.4.3.1.1INTEGERread-onlymandatory
npInfoIPCommittedRate
OBJECT-TYPE
Default committed rate for IP circuits
1.3.6.1.4.1.711.2.1.4.3.1.5INTEGERread-writemandatory
npInfoIPCommittedBurst
OBJECT-TYPE
Default committed burst rate for IP circuits
1.3.6.1.4.1.711.2.1.4.3.1.6INTEGERread-writemandatory
npInfoIPExcessRate
OBJECT-TYPE
Default excess rate for IP circuits
1.3.6.1.4.1.711.2.1.4.3.1.7INTEGERread-writemandatory
npInfoIPExcessBurst
OBJECT-TYPE
Default excess burst rate for IP circuits
1.3.6.1.4.1.711.2.1.4.3.1.8INTEGERread-writemandatory
npInfoIPNCircuits
OBJECT-TYPE
Number of IP circuits supported
1.3.6.1.4.1.711.2.1.4.3.1.9INTEGERread-writemandatory
npInfoAdminOperTrigger
OBJECT-TYPE
When proper commands written to this variable the LCC attempts to change the state of the port such that the oper status reflects the desired admin status.
1.3.6.1.4.1.711.2.1.4.3.1.99INTEGER {trigger(1), other(99)}read-writemandatory
clc1InfoTable
OBJECT-TYPE
Edge Port Address table specific Information
1.3.6.1.4.1.711.2.1.4.4not-accessiblemandatory
clc1InfoEntry
OBJECT-TYPE
An entry in the Edge Port Address table.
1.3.6.1.4.1.711.2.1.4.4.1not-accessiblemandatory
clc1InfoIfIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.4.4.1.1INTEGERread-onlymandatory
clc1InfoOperProtocol
OBJECT-TYPE
Operational higher level protocol stack to support on this port.
1.3.6.1.4.1.711.2.1.4.4.1.4INTEGER {trunk(1), atmUni(2), unknown(3)}read-onlymandatory
clc1InfoAdminProtocol
OBJECT-TYPE
Administratively desired higher level protocol stack to support on this port.
1.3.6.1.4.1.711.2.1.4.4.1.5INTEGER {trunk(1), atmUni(2), unknown(3)}read-writemandatory
clc1InfoOperLoopMode
OBJECT-TYPE
Operational loop mode for this port: none, internal, or external.
1.3.6.1.4.1.711.2.1.4.4.1.6INTEGER {none(1), internal(2), external(3)}read-onlymandatory
clc1InfoAdminLoopMode
OBJECT-TYPE
Administrative or desired loop mode for this port: none, internal, or external.
1.3.6.1.4.1.711.2.1.4.4.1.7INTEGER {none(1), internal(2), external(3)}read-writemandatory
clc1InfoOperControlBandwidthSize
OBJECT-TYPE
The current operation value of the control bandwidth size for this port. This is a scaling factor. This value is multiplied by the port bit rate and the result divided by 1000 to derive the actual bandwidth.
1.3.6.1.4.1.711.2.1.4.4.1.10INTEGERread-onlymandatory
clc1InfoAdminControlBandwidthSize
OBJECT-TYPE
The current administratively desired value of the control bandwidth size for this port. Setting the trigger variable clc1InfoAdimOperTrigger will cause this value to become the operation value. This is a scaling factor. This value is multiplied by the port bit rate and the result divided by 1000 to derive the actual bandwidth.
1.3.6.1.4.1.711.2.1.4.4.1.11INTEGERread-writemandatory
clc1InfoOperDataBandwidthSize
OBJECT-TYPE
The current operation value of the data bandwidth size for this port. This is a scaling factor. This value is multiplied by the port bit rate and the result divided by 1000 to derive the actual bandwidth.
1.3.6.1.4.1.711.2.1.4.4.1.12INTEGERread-onlymandatory
clc1InfoAdminDataBandwidthSize
OBJECT-TYPE
The current administratively desired value of the data bandwidth size for this port. Setting the trigger variable clc1InfoAdimOperTrigger will cause this value to become the operation value. This is a scaling factor. This value is multiplied by the port bit rate and the result divided by 1000 to derive the actual bandwidth.
1.3.6.1.4.1.711.2.1.4.4.1.13INTEGERread-writemandatory
clc1InfoLcAutoEnable
OBJECT-TYPE
State of the LC auto-enable flag for this port. If enabled the port will be enable at LC boot time. If disabled the port will remain disabled until configured and started by the LCC software on the NP. This parameter is set in the LC EEPROM by portctl.
1.3.6.1.4.1.711.2.1.4.4.1.14INTEGER {enabled(1), disabled(2)}read-onlymandatory
clc1InfoLcDebugLevel
OBJECT-TYPE
Value of the LC debug level variable for this port. This parameter is set in the LC EEPROM by portctl.
1.3.6.1.4.1.711.2.1.4.4.1.15INTEGERread-onlymandatory
clc1InfoOperScramble
OBJECT-TYPE
Operational value for Cell Payload scrambling used for this port.
1.3.6.1.4.1.711.2.1.4.4.1.16INTEGER {scrambleEnable(1), scrambleDisable(2)}read-onlymandatory
clc1InfoAdminScramble
OBJECT-TYPE
Administrative value for Cell Payload scrambling used for this port. Setting the trigger variable clc1InfoAdimOperTrigger will cause this value to become the operation value.
1.3.6.1.4.1.711.2.1.4.4.1.17INTEGER {scrambleEnable(1), scrambleDisable(2)}read-writemandatory
clc1InfoDataCellCapacity
OBJECT-TYPE
The portion of this port's capacity in cells that is allocated for data traffic.
1.3.6.1.4.1.711.2.1.4.4.1.18INTEGERread-onlymandatory
clc1InfoDataCellAvailable
OBJECT-TYPE
The portion of this port's capacity in cells that is available for data traffic. This variable is adjusted for the bandwidth consumed by VCs created using this port. It does not count VCs which have been configured but not yet established.
1.3.6.1.4.1.711.2.1.4.4.1.19INTEGERread-onlymandatory
clc1InfoLinkUtilization
OBJECT-TYPE
This is an estimated utilization on the link.
1.3.6.1.4.1.711.2.1.4.4.1.20INTEGERread-onlymandatory
clc1InfoOperClock
OBJECT-TYPE
Operational value for the source of transmit clock for this port.
1.3.6.1.4.1.711.2.1.4.4.1.21INTEGER {internalClock(1), externalClock(2)}read-onlymandatory
clc1InfoAdminClock
OBJECT-TYPE
Administrative value for the source of transmit clock used for this port. Setting the trigger variable clc1InfoAdimOperTrigger will cause this value to become the operation value.
1.3.6.1.4.1.711.2.1.4.4.1.22INTEGER {internalClock(1), externalClock(2)}read-writemandatory
clc1InfoAdminOperTrigger
OBJECT-TYPE
When proper commands written to this variable the LCC attempts to change the state of the port such that the oper status reflects the desired admin status.
1.3.6.1.4.1.711.2.1.4.4.1.99INTEGER {trigger(1), other(99)}read-writemandatory
oc3InfoTable
OBJECT-TYPE
Edge Port Address table specific Information
1.3.6.1.4.1.711.2.1.4.5not-accessiblemandatory
oc3InfoEntry
OBJECT-TYPE
An entry in the Edge Port Address table.
1.3.6.1.4.1.711.2.1.4.5.1not-accessiblemandatory
oc3InfoReceiveSignalDetect
OBJECT-TYPE
This value indicates that a receive signal has been detected on thei port
1.3.6.1.4.1.711.2.1.4.5.1.1INTEGER {active(1), inactive(2)}read-onlymandatory
oc3InfoTransmitSafetySwitch
OBJECT-TYPE
State of the Safety Switch with the single mode interface. When the saftey switch is enabled, the laser is disabled. This variable is undefined for multimode interfaces.
1.3.6.1.4.1.711.2.1.4.5.1.2INTEGER {enabled(1), disabled(2)}read-onlymandatory
oc3InfoMediumType
OBJECT-TYPE
This variable identifies whether a SONET or a SDH signal is used across this interface.
1.3.6.1.4.1.711.2.1.4.5.1.3INTEGER {sonet(1), sdh(2)}read-writemandatory
congestionAvoidance
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.5
caMaxIntervalPermitLimit
OBJECT-TYPE
The maximum interval at which permit limits are to be reported by trunk and outgoing edge cards.
1.3.6.1.4.1.711.2.1.5.1INTEGERread-writemandatory
caMinIntervalPermitLimit
OBJECT-TYPE
The minimum interval at which permit limits are to be reported by trunk and outgoing edge cards.
1.3.6.1.4.1.711.2.1.5.2INTEGERread-writemandatory
caMinIntervalCaInfo
OBJECT-TYPE
The minimum interval at which CA information processes are to distribute aggregated CA updates to input edge cards.
1.3.6.1.4.1.711.2.1.5.3INTEGERread-writemandatory
mmaInfo
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.6
mmaDbActive
OBJECT-TYPE
Controls and displays state of persistent database used by MMA. Primary use of this variable was to allow release 1 configuration systems to shut off the database before it was replaced with a new one and then re-activated. The release 2 configuration mechanism depends on mmaSetLock to backup and coordinate configuration updates.
1.3.6.1.4.1.711.2.1.6.1INTEGER {inactive(1), newDBactive(2)}read-writemandatory
mmaTrapFilter
OBJECT-TYPE
Value of highest priority trap that will be be forwarded to any NMS sites. For example if set to mediumPriority then mediumPrioriy and highPriority messages will be forwarded
1.3.6.1.4.1.711.2.1.6.2INTEGER {operational(1), informational(2), trace(3), debug(4)}read-writemandatory
mmaTrapLanguage
OBJECT-TYPE
Langauage to be used for the text of traps.
1.3.6.1.4.1.711.2.1.6.3INTEGER {english(1)}read-writemandatory
mmaCollectionSpace
OBJECT-TYPE
Max size of disk space available for collecting autonomous traps. Actual size is mmaCollectionSpace * 1024
1.3.6.1.4.1.711.2.1.6.4INTEGERread-writemandatory
mmaConfigHost
OBJECT-TYPE
Host supplying configuration file
1.3.6.1.4.1.711.2.1.6.5OCTET STRING (SIZE(0..255))read-writemandatory
mmaConfigAuthor
OBJECT-TYPE
Person who last changed configuration file
1.3.6.1.4.1.711.2.1.6.6OCTET STRING (SIZE(0..255))read-writemandatory
mmaConfigID
OBJECT-TYPE
Configuration ID set by configuration program
1.3.6.1.4.1.711.2.1.6.7INTEGERread-writemandatory
mmaSetLock
OBJECT-TYPE
If a user locks this field (2 or 3), set commands are accepted only from that IP address. The lock times out if the session is idle for two minutes. There are two configuration files: mma.db.pag and mma.db.dir. If set to lockPermanent(3), these files are copied to mma.db.BAK.pag and mma.db.BAK.dir, and sets are written to the configuration files. Otherwise sets are written to run-time memory only. To recover backup configuration files, the user must log in to the LightStream node and rename the files.
1.3.6.1.4.1.711.2.1.6.8INTEGER {unlock(1), lockVolatile(2), lockPermanent(3)}read-writemandatory
mmaPID
OBJECT-TYPE
PID of the MMA process
1.3.6.1.4.1.711.2.1.6.9INTEGERread-onlymandatory
mmaTrapLog
OBJECT-TYPE
Trap log control field. If enabled the MMA will log traps received from LWMA clients to disk. It saves traps into a 'circular file' such that only the last number of traps are on disk.
1.3.6.1.4.1.711.2.1.6.10INTEGER {enabled(1), disabled(2)}read-writemandatory
mmaTrapNumber
OBJECT-TYPE
Trap Number used by the state and action variables
1.3.6.1.4.1.711.2.1.6.13INTEGERread-writemandatory
mmaTrapOnOffState
OBJECT-TYPE
On/Off State of Trap specified in mmaTrapNumber and mmaTrapPidSelector
1.3.6.1.4.1.711.2.1.6.14INTEGER {trapOn(1), trapOff(2), trapEnable(3), trapDisable(4)}read-writemandatory
mmaNumNameTable
OBJECT-TYPE
Table of current file transfers
1.3.6.1.4.1.711.2.1.6.16not-accessiblemandatory
mmaNumNameEntry
OBJECT-TYPE
An entry in the file transfer table.
1.3.6.1.4.1.711.2.1.6.16.1not-accessiblemandatory
mmaNumNameNumber
OBJECT-TYPE
Unique Index consisting of chassis ID.
1.3.6.1.4.1.711.2.1.6.16.1.1INTEGERread-onlymandatory
mmaNumName
OBJECT-TYPE
Name of chassis corresponding to value of mmaNumNameNumber.
1.3.6.1.4.1.711.2.1.6.16.1.2DisplayStringread-onlymandatory
mmaLwmpTimeouts
OBJECT-TYPE
The number of times the MMA did a read on a socket to a chassis-resident process and timed out before the process responded. This object is being added here for debug purposes and may be changed in future releases of the MIB.
1.3.6.1.4.1.711.2.1.6.20Counterread-onlymandatory
collectInfo
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.7
collectTable
OBJECT-TYPE
Collector table of current collections
1.3.6.1.4.1.711.2.1.7.1not-accessiblemandatory
collectEntry
OBJECT-TYPE
An entry in the Collector collection table. (1-n)
1.3.6.1.4.1.711.2.1.7.1.1not-accessiblemandatory
collectIndex
OBJECT-TYPE
Unique Index consisting of collection number.
1.3.6.1.4.1.711.2.1.7.1.1.1INTEGERread-onlymandatory
collectStatus
OBJECT-TYPE
Collection status of this collection row entry.
1.3.6.1.4.1.711.2.1.7.1.1.2INTEGER {valid(1), createRequest(2), underCreation(3), invalid(4)}read-writemandatory
collectStart
OBJECT-TYPE
Collection start time. If specified and status is valid means a collection will start at time. Time is the UNIX real time in seconds.
1.3.6.1.4.1.711.2.1.7.1.1.3INTEGERread-writemandatory
collectFinish
OBJECT-TYPE
Collection finish time in TOD seconds.
1.3.6.1.4.1.711.2.1.7.1.1.4INTEGERread-writemandatory
collectInterval
OBJECT-TYPE
Collection Interval, in seconds.
1.3.6.1.4.1.711.2.1.7.1.1.5INTEGERread-writemandatory
collectFileName
OBJECT-TYPE
Automatically generated filename for this collection. The file name is 'Collect.n' where 'n' is the collectIndex.
1.3.6.1.4.1.711.2.1.7.1.1.6DisplayString (SIZE(0..255))read-onlymandatory
collectFileSize
OBJECT-TYPE
Max Size of the circular file named in collectFileName. Actual maximum size of file is value of collectFileSize * 1024.
1.3.6.1.4.1.711.2.1.7.1.1.7INTEGERread-writemandatory
collectOperStatus
OBJECT-TYPE
Collection status of this collection row entry.
1.3.6.1.4.1.711.2.1.7.1.1.8INTEGER {waiting(1), running(2), underCreation(3)}read-writemandatory
collectDataBase
OBJECT-TYPE
Collector table of current collections
1.3.6.1.4.1.711.2.1.7.2not-accessiblemandatory
collectDbEntry
OBJECT-TYPE
An entry in the Collector group database. (1-n)
1.3.6.1.4.1.711.2.1.7.2.1not-accessiblemandatory
collectDBIndex
OBJECT-TYPE
Unique Index equal to collectIndex
1.3.6.1.4.1.711.2.1.7.2.1.1INTEGERread-onlymandatory
collectDBInstance
OBJECT-TYPE
Record instance within a group ID
1.3.6.1.4.1.711.2.1.7.2.1.2INTEGERread-onlymandatory
collectDBObjectID
OBJECT-TYPE
Object identifier of a member of a group specified by the group ID and instance.
1.3.6.1.4.1.711.2.1.7.2.1.3OBJECT IDENTIFIERread-writemandatory
collectDBStatus
OBJECT-TYPE
Collection status of this collection database row entry.
1.3.6.1.4.1.711.2.1.7.2.1.4INTEGER {valid(1), createRequest(2), underCreation(3), invalid(4)}read-writemandatory
collectCommunityName
OBJECT-TYPE
Used by Collector with its SNMP requests to the MMA.
1.3.6.1.4.1.711.2.1.7.3DisplayString (SIZE(0..255))read-writemandatory
rmonCommunityName
OBJECT-TYPE
Used by RMON/Collector with its SNMP requests to the MMA.
1.3.6.1.4.1.711.2.1.7.4DisplayString (SIZE(0..255))read-writemandatory
lsPortProtocols
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.8
edgePort
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.8.1
edgePortTable
OBJECT-TYPE
EdgePort Port Address table specific information
1.3.6.1.4.1.711.2.1.8.1.1not-accessiblemandatory
edgePortEntry
OBJECT-TYPE
An entry in the EdgePort Port Address table.
1.3.6.1.4.1.711.2.1.8.1.1.1not-accessiblemandatory
edgeIfIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.8.1.1.1.1INTEGERread-onlymandatory
edgeUpcType
OBJECT-TYPE
Usage Parameter Control model type. This parameter selects the UPC model, which regulates the flow of data into the network.
1.3.6.1.4.1.711.2.1.8.1.1.1.2INTEGER {ansiCompliant(1)}read-writemandatory
edgeUserDataPerCell
OBJECT-TYPE
User data bits per cell. This specifies the expected packing efficiency when frames are converted to cells. It does not affect the actual packing of data into cells but serves as an estimate on which bandwidth allocation and other connection related functions will be based.
1.3.6.1.4.1.711.2.1.8.1.1.1.3INTEGER (1..384)read-writemandatory
edgeCellDelayVariance
OBJECT-TYPE
Cell Delay Variance in microseconds. This is the typical variance in the delay added as a cell is processed by an switch
1.3.6.1.4.1.711.2.1.8.1.1.1.4INTEGERread-writemandatory
edgePrincipalScale
OBJECT-TYPE
Principal bandwidth scaling factor. This is used to scale down the actual amount of bandwidth to allocate for the principal portion of a VC's bandwidth. This is specified as a codepoint as follows: Codepoints Meaning Comment - ---------- ------- ------- 0 - 100 x / 100 e.g., 1 => .01 101 - 109 x - 100 / 1000 e.g., 101 => .001
1.3.6.1.4.1.711.2.1.8.1.1.1.5INTEGERread-writemandatory
edgeSecondaryScale
OBJECT-TYPE
Secondary bandwidth scaling factor. This is used to scale down the actual amount of bandwidth to allocate for the Secondary portion of a VC's bandwidth. This is specified as a codepoint as follows: Codepoints Meaning Comment - ---------- ------- ------- 0 - 100 x / 100 e.g., 1 => .01 101 - 109 x - 100 / 1000 e.g., 101 => .001
1.3.6.1.4.1.711.2.1.8.1.1.1.6INTEGERread-writemandatory
edgeMeteringFactor
OBJECT-TYPE
Scale factor for the metering time charge, a value (divided by 256) by which to increase the time or slow down metering of traffic into the network. A value of 256 would typically keep the metering rate close to the minimum allowable rate for the aggregate information rate for the group of circuits being metered.
1.3.6.1.4.1.711.2.1.8.1.1.1.7INTEGERread-writemandatory
edgeMeteringBurstSize
OBJECT-TYPE
This is the minimum number of cells to burst at a time
1.3.6.1.4.1.711.2.1.8.1.1.1.8INTEGERread-writemandatory
edgeCallSetupRetry
OBJECT-TYPE
This specifies the initial time to wait between successive failed attempts to establish a connection. This interval is in seconds. An incremental backoff algorithm may applied to this value. See Parameter edgeCallSetupBackoff.
1.3.6.1.4.1.711.2.1.8.1.1.1.9INTEGER (1..3600)read-writemandatory
edgeCallSetupBackoff
OBJECT-TYPE
This specifies the maximum power of 2 to backoff in call setup retry attempts. For each retry up to this maxumim the retry timer will be adjusted by multipliing by 2**(n). The first retry will be multiplied by 2**0 or 1, the second by 2**1 or 2, and so on. The variable can range from 1 to 10.
1.3.6.1.4.1.711.2.1.8.1.1.1.10INTEGER (1..10)read-writemandatory
edgeMaxFrameSize
OBJECT-TYPE
This specifies the maximum frame size that can be transmitted on this edge port. The size is specified in bytes.
1.3.6.1.4.1.711.2.1.8.1.1.1.11INTEGER (48..8152)read-writemandatory
frDceInfo
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.8.2
frProvMiTable
OBJECT-TYPE
The Parameters for the Data Link Connection Management Interface for the frame relay service on this interface.
1.3.6.1.4.1.711.2.1.8.2.1not-accessiblemandatory
frProvMiEntry
OBJECT-TYPE
The Parameters for a particular Data Link Con- nection Management Interface.
1.3.6.1.4.1.711.2.1.8.2.1.1not-accessiblemandatory
frProvMiIfIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.8.2.1.1.1INTEGERread-onlymandatory
frProvMiState
OBJECT-TYPE
This variable states which Data Link Connec- tion Management scheme is active (and by impli- cation, what DLCI it uses) on the Frame Relay interface.
1.3.6.1.4.1.711.2.1.8.2.1.1.2INTEGER {noLmiConfigured(1), lmiFRIF(2), ansiT1-617-D(3), ccittQ-933-A(4)}read-writemandatory
frProvMiAddressLen
OBJECT-TYPE
This variable states which address length in octets. In the case of Q922 format, the length indicates the entire length of the address in- cluding the control portion.
1.3.6.1.4.1.711.2.1.8.2.1.1.3INTEGER {two-octets(2)}read-writemandatory
frProvMiNetRequestInterval
OBJECT-TYPE
This is the maximum number of seconds between successive status enquiry messages. If a status enquiry message does not arrive within this time an error event occurs. This is also refered to as T392 and nT2. Must be 5 in second intervals as defined in the ANSI and ITU specifications.
1.3.6.1.4.1.711.2.1.8.2.1.1.4INTEGER (5..30)read-writemandatory
frProvMiNetErrorThreshold
OBJECT-TYPE
This is the maximum number of unanswered Status Enquiries the equipment shall accept be- fore declaring the interface down by the network side of the interface. This is also refered to as N392 and nN2.
1.3.6.1.4.1.711.2.1.8.2.1.1.5INTEGER (1..10)read-writemandatory
frProvMiNetMonitoredEvents
OBJECT-TYPE
This is the number of status polling intervals over which the error threshold is counted. For example, if within 'MonitoredEvents' number of events the station receives 'ErrorThreshold' number of errors, the interface is marked as down. This is also refered to as N393 and nN3.
1.3.6.1.4.1.711.2.1.8.2.1.1.6INTEGER (1..10)read-writemandatory
frProvMiMaxSupportedVCs
OBJECT-TYPE
The maximum number of Virtual Circuits allowed for this interface. Usually dictated by the Frame Relay network. This variable will limit the creation of more than this number of VCs. It will not delete VCs which have already been configured at the time this parameter is set. In response to a SET, if a value less than zero or higher than the agent's maximal capability is configured, the agent should respond bad- Value
1.3.6.1.4.1.711.2.1.8.2.1.1.7INTEGERread-writemandatory
frProvMiMulticast
OBJECT-TYPE
This indicates whether the Frame Relay inter- face is using a multicast service.
1.3.6.1.4.1.711.2.1.8.2.1.1.8INTEGER {nonBroadcast(1)}read-writemandatory
frProvMiUserPollingInterval
OBJECT-TYPE
This is the number of seconds between succes- sive status enquiry messages sent by the user portion of a NNI interface. This is also refered to as T391 and nT1.
1.3.6.1.4.1.711.2.1.8.2.1.1.9INTEGER (5..30)read-writemandatory
frProvMiUserFullEnquiryInterval
OBJECT-TYPE
Number of status enquiry intervals that pass before issuance of a full status enquiry mes- sage by the user portion of a NNI interface. This is also refered to as N391 and nN1.
1.3.6.1.4.1.711.2.1.8.2.1.1.10INTEGER (1..255)read-writemandatory
frProvMiUserErrorThreshold
OBJECT-TYPE
This is the maximum number of unanswered Status Enquiries the equipment shall accept be- fore declaring the interface down by the user side of the NNI interface. This is also refered to as N392 and nT2.
1.3.6.1.4.1.711.2.1.8.2.1.1.11INTEGER (1..10)read-writemandatory
frProvMiUserMonitoredEvents
OBJECT-TYPE
This is the number of status polling intervals over which the error threshold is counted on a NNI interface. For example, if within 'MonitoredEvents' number of events the station receives 'ErrorThreshold' number of errors, the interface is marked as down.
1.3.6.1.4.1.711.2.1.8.2.1.1.12INTEGER (1..10)read-writemandatory
frProvMiNetInterfaceType
OBJECT-TYPE
This variable states which type of Network Interface should be used. UNI provides for a User Network Interface, while NNI provides for a Network to Network Interface.
1.3.6.1.4.1.711.2.1.8.2.1.1.13INTEGER {niUNI(1), niNNI(2)}read-writemandatory
frCktInfo
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.8.3
frCktCfgTable
OBJECT-TYPE
A table containing information about specific DLCIs and corresponding circuits.
1.3.6.1.4.1.711.2.1.8.3.1not-accessiblemandatory
frCktEntry
OBJECT-TYPE
The information regarding a single Data Link Connection Identifier.
1.3.6.1.4.1.711.2.1.8.3.1.1not-accessiblemandatory
frCktSrcNode
OBJECT-TYPE
The Node Identifier for the source end of this virtual circuit.
1.3.6.1.4.1.711.2.1.8.3.1.1.1INTEGERread-onlymandatory
frCktSrcIfIndex
OBJECT-TYPE
The ifIndex Value of the ifEntry this virtual circuit is layered onto. See comments above to calculate ifIndex value.
1.3.6.1.4.1.711.2.1.8.3.1.1.2INTEGERread-onlymandatory
frCktSrcDlci
OBJECT-TYPE
The Data Link Connection Identifier for this virtual circuit.
1.3.6.1.4.1.711.2.1.8.3.1.1.3LightStreamDLCIread-onlymandatory
frCktAdminDestNode
OBJECT-TYPE
The Node Identifier for the Destination end of this virtual circuit. This variable takes effect when frCktStatus is set.
1.3.6.1.4.1.711.2.1.8.3.1.1.10INTEGERread-writemandatory
frCktOperDestNode
OBJECT-TYPE
The Node Identifier for the Destination end of this virtual circuit.
1.3.6.1.4.1.711.2.1.8.3.1.1.11INTEGERread-onlymandatory
frCktAdminDestIfIndex
OBJECT-TYPE
The ifIndex Value of the ifEntry this virtual circuit is layered onto. See comments above to calculate ifIndex. This variable takes effect when frCktStatus is set.
1.3.6.1.4.1.711.2.1.8.3.1.1.12INTEGERread-writemandatory
frCktOperDestIfIndex
OBJECT-TYPE
The ifIndex Value of the ifEntry this virtual circuit is layered onto. See comments above to calculate ifIndex.
1.3.6.1.4.1.711.2.1.8.3.1.1.13INTEGERread-onlymandatory
frCktAdminDestDlci
OBJECT-TYPE
The Data Link Connection Identifier for this virtual circuit. This variable takes effect when frCktStatus is set.
1.3.6.1.4.1.711.2.1.8.3.1.1.14LightStreamDLCIread-writemandatory
frCktOperDestDlci
OBJECT-TYPE
The Data Link Connection Identifier for this virtual circuit.
1.3.6.1.4.1.711.2.1.8.3.1.1.15LightStreamDLCIread-onlymandatory
frCktAdminSrcInsuredRate
OBJECT-TYPE
This variable, the Insured Rate is the rate of insured data that the network commits to supporting under normal network conditions from Source to Destination. It is specified in bits per second. This variable takes effect when frCktStatus is set.
1.3.6.1.4.1.711.2.1.8.3.1.1.25INTEGERread-writemandatory
frCktOperSrcInsuredRate
OBJECT-TYPE
This variable, the Insured Rate is the rate of insured data that the network commits to supporting under normal network conditions from source to destination. It is specified in bits per second.
1.3.6.1.4.1.711.2.1.8.3.1.1.26INTEGERread-onlymandatory
frCktAdminSrcInsuredBurst
OBJECT-TYPE
This variable indicates the Insured Burst Size, which is the amount of insured data, in bytes, that the network agrees to transfer under normal conditions, during the measurement interval from source to destination. This variable takes effect when frCktStatus is set.
1.3.6.1.4.1.711.2.1.8.3.1.1.27INTEGERread-writemandatory
frCktOperSrcInsuredBurst
OBJECT-TYPE
This variable indicates the Insured Burst Size, which is the amount of insured data, in bytes, that the network agrees to transfer under normal conditions, during the measurement interval from source to destination.
1.3.6.1.4.1.711.2.1.8.3.1.1.28INTEGERread-onlymandatory
frCktAdminSrcMaxRate
OBJECT-TYPE
This variable, the Maximum Rate is the the maximum amount of insured plus uninsured data throughput that the network agrees to support from source to destination. It is specified in bits per second. This variable takes effect when frCktStatus is set.
1.3.6.1.4.1.711.2.1.8.3.1.1.29INTEGERread-writemandatory
frCktOperSrcMaxRate
OBJECT-TYPE
This variable, the Maximum Rate is the the maximum amount of insured plus uninsured data throughput that the network agrees to support from source to destination. It is specified in bits per second.
1.3.6.1.4.1.711.2.1.8.3.1.1.30INTEGERread-onlymandatory
frCktAdminSrcMaxBurst
OBJECT-TYPE
This variable indicates the Total Burst Size, which is the maximum amount of insured plus uninsured data bytes that the network will at- tempt to deliver over the measurement interval from the Source to the Destination. This variable takes effect when frCktStatus is set.
1.3.6.1.4.1.711.2.1.8.3.1.1.31INTEGERread-writemandatory
frCktOperSrcMaxBurst
OBJECT-TYPE
This variable indicates the Total Burst Size, which is the maximum amount of insured plus uninsured data bytes that the network will at- tempt to deliver over the measurement interval from the Source to the Destination.
1.3.6.1.4.1.711.2.1.8.3.1.1.32INTEGERread-onlymandatory
frCktAdminDestInsuredRate
OBJECT-TYPE
This variable, the Insured Rate is the rate of insured data that the network commits to supporting under normal network conditions from destination to source. It is specified in bits per second. This variable takes effect when frCktStatus is set.
1.3.6.1.4.1.711.2.1.8.3.1.1.33INTEGERnot-accessiblemandatory
frCktOperDestInsuredRate
OBJECT-TYPE
This variable, the Insured Rate is the rate of insured data that the network commits to supporting under normal network conditions from destination to source. It is specified in bits per second.
1.3.6.1.4.1.711.2.1.8.3.1.1.34INTEGERread-onlymandatory
frCktAdminDestInsuredBurst
OBJECT-TYPE
This variable indicates the Insured Burst Size, which is the amount of insured data, in bytes, that the network agrees to transfer under normal conditions, during the measurement interval from destination to source. This variable takes effect when frCktStatus is set.
1.3.6.1.4.1.711.2.1.8.3.1.1.35INTEGERnot-accessiblemandatory
frCktOperDestInsuredBurst
OBJECT-TYPE
This variable indicates the Insured Burst Size, which is the amount of insured data, in bytes, that the network agrees to transfer under normal conditions, during the measurement interval from destination to source.
1.3.6.1.4.1.711.2.1.8.3.1.1.36INTEGERread-onlymandatory
frCktAdminDestMaxRate
OBJECT-TYPE
This variable, the Maximum Rate is the the maximum amount of insured plus uninsured data throughput that the network agrees to transfer from destination to source. It is specified in bits per second. This variable takes effect when frCktStatus is set.
1.3.6.1.4.1.711.2.1.8.3.1.1.37INTEGERnot-accessiblemandatory
frCktOperDestMaxRate
OBJECT-TYPE
This variable, the maximum rate is the total data throughput that the network will allow to pass on this VC under optimal network conditions from destination to source. It is specified in bits per second.
1.3.6.1.4.1.711.2.1.8.3.1.1.38INTEGERread-onlymandatory
frCktAdminDestMaxBurst
OBJECT-TYPE
This variable indicates the Total Burst Size, which is the maximum amount of insured plus uninsured data bytes that the network will at- tempt to deliver over the measurement interval from the Destination to the Source. This variable takes effect when frCktStatus is set.
1.3.6.1.4.1.711.2.1.8.3.1.1.39INTEGERnot-accessiblemandatory
frCktOperDestMaxBurst
OBJECT-TYPE
This variable indicates the Total Burst Size, which is the maximum amount of insured plus uninsured data bytes that the network will at- tempt to deliver over the measurement interval from the Destination to the Source.
1.3.6.1.4.1.711.2.1.8.3.1.1.40INTEGERread-onlymandatory
frCktOperSecondaryScale
OBJECT-TYPE
Operational version of the Secondary bandwidth scaling factor. This is used to scale down the actual amount of bandwidth to allocate for the Secondary portion of a VC's bandwidth. This is specified as a codepoint as follows: Codepoints Meaning Comment - ---------- ------- ------- 0 - 100 x / 100 e.g., 1 => .01 101 - 109 x - 100 / 1000 e.g., 101 => .001 254 (reserved) 255 (per-port dflt)
1.3.6.1.4.1.711.2.1.8.3.1.1.41INTEGERread-onlymandatory
frCktAdminSecondaryScale
OBJECT-TYPE
Secondary bandwidth scaling factor. This is used to scale down the actual amount of bandwidth to allocate for the Secondary portion of a VC's bandwidth. This is specified as a codepoint as follows: Codepoints Meaning Comment - ---------- ------- ------- 0 - 100 x / 100 e.g., 1 => .01 101 - 109 x - 100 / 1000 e.g., 101 => .001 254 (reserved) 255 (per-port dflt)
1.3.6.1.4.1.711.2.1.8.3.1.1.42INTEGERread-writemandatory
frCktOperPrinBwType
OBJECT-TYPE
This variable indicates the type of service supported on primary portion of this Virtual Circuit.
1.3.6.1.4.1.711.2.1.8.3.1.1.43INTEGER {guaranteed(1), insured(2)}read-onlymandatory
frCktAdminPrinBwType
OBJECT-TYPE
This variable indicates the type of service supported on primary portion of this Virtual Circuit. This variable takes effect when frCktStatus is set.
1.3.6.1.4.1.711.2.1.8.3.1.1.44INTEGER {guaranteed(1), insured(2)}read-writemandatory
frCktOperTransPri
OBJECT-TYPE
This variable indicates the transfer priority supported on this Virtual Circuit.
1.3.6.1.4.1.711.2.1.8.3.1.1.45INTEGER (0..1)read-onlymandatory
frCktAdminTransPri
OBJECT-TYPE
This variable indicates the transfer priority supported on this Virtual Circuit. This variable takes effect when frCktStatus is set.
1.3.6.1.4.1.711.2.1.8.3.1.1.46INTEGER (0..1)read-writemandatory
frCktOperUserDataPerCell
OBJECT-TYPE
Operational User data bits per cell, specifies the expected packing efficiency when frames are converted to cells. It does not affect the actual packing of data into cells but serves as an estimate on which bandwidth allocation and other connection related functions will be based.
1.3.6.1.4.1.711.2.1.8.3.1.1.47INTEGER (0..384)read-onlymandatory
frCktAdminUserDataPerCell
OBJECT-TYPE
Administrative User data bits per cell, specifies the expected packing efficiency when frames are converted to cells. It does not affect the actual packing of data into cells but serves as an estimate on which bandwidth allocation and other connection related functions will be based. This variable takes effect when frCktStatus is set.
1.3.6.1.4.1.711.2.1.8.3.1.1.48INTEGER (0..384)read-writemandatory
frCktStatus
OBJECT-TYPE
This variable indicates the Status of this Virtual Circuit. It may be enabled or disabled. In order to modify a Virtual Circuit, the new desired variables should be modified and then this variable should be set (or set again) to enabled. At that time desired variables will become the actual variables. To remove a PVC, set its status to delete. By default, if not configured when creating the entry, the status is disabled.
1.3.6.1.4.1.711.2.1.8.3.1.1.99INTEGER {enabled(1), disabled(2), delete(3)}read-writemandatory
frCktInfoTable
OBJECT-TYPE
A table containing information about specific DLCIs and corresponding circuits.
1.3.6.1.4.1.711.2.1.8.3.2not-accessiblemandatory
frCktInfoEntry
OBJECT-TYPE
The information regarding a single Data Link Connection Identifier.
1.3.6.1.4.1.711.2.1.8.3.2.1not-accessiblemandatory
frCktInfoIfIndex
OBJECT-TYPE
The ifIndex Value of the ifEntry this virtual circuit is layered onto. See comments above to calculate ifIndex.
1.3.6.1.4.1.711.2.1.8.3.2.1.1INTEGERread-onlymandatory
frCktInfoDlci
OBJECT-TYPE
The Data Link Connection Identifier for this virtual circuit.
1.3.6.1.4.1.711.2.1.8.3.2.1.2LightStreamDLCIread-onlymandatory
frCktInfoLclLMI
OBJECT-TYPE
This variable indicates the local LMI state of the circuit.
1.3.6.1.4.1.711.2.1.8.3.2.1.3INTEGER {active(1), inactive(2)}read-onlymandatory
frCktInfoRmtLMI
OBJECT-TYPE
This variable indicates the remote LMI state of the circuit.
1.3.6.1.4.1.711.2.1.8.3.2.1.4INTEGER {active(1), inactive(2)}read-onlymandatory
frCktInfoCallIDIncoming
OBJECT-TYPE
This variable indicates the Call Identifier assigned to the incomming half of this circuit.
1.3.6.1.4.1.711.2.1.8.3.2.1.5INTEGERread-onlymandatory
frCktInfoCallIDOutgoing
OBJECT-TYPE
This variable indicates the Call Identifier assigned to the outgoing half of this circuit.
1.3.6.1.4.1.711.2.1.8.3.2.1.6INTEGERread-onlymandatory
frCktInfoDownstreamState
OBJECT-TYPE
This variable indicates the state of the downstream half of the circuit. (passing data from the local port to the remote end of the network)
1.3.6.1.4.1.711.2.1.8.3.2.1.7INTEGER {active(1), inactive(2)}read-onlymandatory
frCktInfoUpstreamState
OBJECT-TYPE
This variable indicates the state of the upstream half of the circuit. (passing data from the port at the remote end of the network to the local port)
1.3.6.1.4.1.711.2.1.8.3.2.1.8INTEGER {active(1), inactive(2)}read-onlymandatory
frCktInfoLastAtmErr
OBJECT-TYPE
This variable indicates the last error, if any, returned by the Atm Connection Management layer when an attempt was made to create a connection or flow.
1.3.6.1.4.1.711.2.1.8.3.2.1.9OCTET STRINGread-onlymandatory
frCktInfoDataCellsRequired
OBJECT-TYPE
This variable indicates the bandwidth in cells needed to establish this VC. The value returned combines the committed and the Secondary bandwidth needs.
1.3.6.1.4.1.711.2.1.8.3.2.1.10INTEGERread-onlymandatory
frCktInfoLastAtmLocation
OBJECT-TYPE
This variable indicates the last error, if any, returned by the Atm Connection Management layer when an attempt was made to create a connection or flow. The format of the string is: nodenum:ifIndex where all numbers are specified in decimal. For example 5142:6000 refers to the remote endpoint with node 5142, ifIndex 6000 (slot 6 port 0 fr type 0).
1.3.6.1.4.1.711.2.1.8.3.2.1.11DisplayString (SIZE(0..30))read-onlymandatory
ffCktInfo
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.8.4
ffCktCfgTable
OBJECT-TYPE
A table containing information about Frame Forwarding circuits for every port.
1.3.6.1.4.1.711.2.1.8.4.1not-accessiblemandatory
ffCktEntry
OBJECT-TYPE
The information regarding a single Data Link Connection Identifier.
1.3.6.1.4.1.711.2.1.8.4.1.1not-accessiblemandatory
ffCktSrcNode
OBJECT-TYPE
The Node Identifier for the source end of this virtual circuit.
1.3.6.1.4.1.711.2.1.8.4.1.1.1INTEGERread-onlymandatory
ffCktSrcIfIndex
OBJECT-TYPE
The ifIndex Value of the ifEntry this virtual circuit is layered onto. See above comments to calculate ifIndex.
1.3.6.1.4.1.711.2.1.8.4.1.1.2INTEGERread-onlymandatory
ffCktAdminDestNode
OBJECT-TYPE
The Node Identifier for the Destination end of this virtual circuit. This variable takes effect when ffCktStatus is set.
1.3.6.1.4.1.711.2.1.8.4.1.1.9INTEGERread-writemandatory
ffCktOperDestNode
OBJECT-TYPE
The Node Identifier for the Destination end of this virtual circuit.
1.3.6.1.4.1.711.2.1.8.4.1.1.10INTEGERread-onlymandatory
ffCktAdminDestIfIndex
OBJECT-TYPE
The ifIndex Value of the ifEntry this virtual circuit is layered onto. See above comments to calculate ifIndex. This variable takes effect when ffCktStatus is set.
1.3.6.1.4.1.711.2.1.8.4.1.1.11INTEGERread-writemandatory
ffCktOperDestIfIndex
OBJECT-TYPE
The ifIndex Value of the ifEntry this virtual circuit is layered onto. See above comments to calculate ifIndex.
1.3.6.1.4.1.711.2.1.8.4.1.1.12INTEGERread-onlymandatory
ffCktAdminSrcInsuredRate
OBJECT-TYPE
This variable, the Insured Rate is the rate of insured data that the network commits to supporting under normal network conditions from source to destination. This is specified in bits per second. This variable takes effect when ffCktStatus is set.
1.3.6.1.4.1.711.2.1.8.4.1.1.21INTEGERread-writemandatory
ffCktOperSrcInsuredRate
OBJECT-TYPE
This variable, the Insured Rate is the rate of insured data that the network commits to supporting under normal network conditions from source to destination. This is specified in bits per second.
1.3.6.1.4.1.711.2.1.8.4.1.1.22INTEGERread-onlymandatory
ffCktAdminSrcInsuredBurst
OBJECT-TYPE
This variable indicates the Insured Burst Size, which is the amount of insured data, in bytes, that the network agrees to transfer under normal conditions, during the measurement interval from source to destination. This variable takes effect when ffCktStatus is set.
1.3.6.1.4.1.711.2.1.8.4.1.1.23INTEGERread-writemandatory
ffCktOperSrcInsuredBurst
OBJECT-TYPE
This variable indicates the Insured Burst Size, which is the amount of insured data, in bytes, that the network agrees to transfer under normal conditions, during the measurement interval from source to destination.
1.3.6.1.4.1.711.2.1.8.4.1.1.24INTEGERread-onlymandatory
ffCktAdminSrcMaxRate
OBJECT-TYPE
This variable, the Maximum Rate is the the maximum amount of insured plus uninsured data throughput that the network agrees to transfer from source to destination. This is specified in bits per second. This variable takes effect when ffCktStatus is set.
1.3.6.1.4.1.711.2.1.8.4.1.1.25INTEGERread-writemandatory
ffCktOperSrcMaxRate
OBJECT-TYPE
This variable, the Maximum Rate is the the maximum amount of insured plus uninsured data throughput that the network agrees to support from source to destination. This is specified in bits per second.
1.3.6.1.4.1.711.2.1.8.4.1.1.26INTEGERread-onlymandatory
ffCktAdminSrcMaxBurst
OBJECT-TYPE
This variable indicates the Total Burst Size, the maximum amount of insured plus uninsured data, in bytes, that the network agrees to transfer under normal conditions, during the measurement interval from source to destination. This variable takes effect when ffCktStatus is set.
1.3.6.1.4.1.711.2.1.8.4.1.1.27INTEGERread-writemandatory
ffCktOperSrcMaxBurst
OBJECT-TYPE
This variable indicates the Total Burst Size, the maximum amount of insured plus uninsured data, in bytes, that the network agrees to transfer under normal conditions, during the measurement interval from source to destination.
1.3.6.1.4.1.711.2.1.8.4.1.1.28INTEGERread-onlymandatory
ffCktAdminDestInsuredRate
OBJECT-TYPE
This variable, the Insured Rate is the rate of insured data that the network commits to supporting under normal network conditions from destination to source. This is specified in bits per second. This variable takes effect when ffCktStatus is set.
1.3.6.1.4.1.711.2.1.8.4.1.1.29INTEGERnot-accessiblemandatory
ffCktOperDestInsuredRate
OBJECT-TYPE
This variable, the Insured Rate is the rate of insured data that the network commits to supporting under normal network conditions from destination to source. This is specified in bits per second.
1.3.6.1.4.1.711.2.1.8.4.1.1.30INTEGERread-onlymandatory
ffCktAdminDestInsuredBurst
OBJECT-TYPE
This variable indicates the Insured Burst Size, which is the amount of insured data, in bytes, that the network agrees to transfer under normal conditions, during the measurement interval from destination to source. This variable takes effect when ffCktStatus is set.
1.3.6.1.4.1.711.2.1.8.4.1.1.31INTEGERnot-accessiblemandatory
ffCktOperDestInsuredBurst
OBJECT-TYPE
This variable indicates the Insured Burst Size, which is the amount of insured data, in bytes, that the network agrees to transfer under normal conditions, during the measurement interval from destination to source.
1.3.6.1.4.1.711.2.1.8.4.1.1.32INTEGERread-onlymandatory
ffCktAdminDestMaxRate
OBJECT-TYPE
This variable, the Maximum Rate is the the maximum amount of insured plus uninsured data throughput that the network agrees to transfer from destination to source. This is specified in bits per second. This variable takes effect when ffCktStatus is set.
1.3.6.1.4.1.711.2.1.8.4.1.1.33INTEGERnot-accessiblemandatory
ffCktOperDestMaxRate
OBJECT-TYPE
This variable, the Maximum Rate is the the maximum amount of insured plus uninsured data throughput that the network agrees to support from destination to source. This is specified in bits per second.
1.3.6.1.4.1.711.2.1.8.4.1.1.34INTEGERread-onlymandatory
ffCktAdminDestMaxBurst
OBJECT-TYPE
This variable indicates the Total Burst Size, the maximum amount of insured plus uninsured data, in bytes, that the network agrees to transfer during the measurement interval from destination to source. This variable takes effect when ffCktStatus is set.
1.3.6.1.4.1.711.2.1.8.4.1.1.35INTEGERnot-accessiblemandatory
ffCktOperDestMaxBurst
OBJECT-TYPE
This variable indicates the Total Burst Size, the maximum amount of insured plus uninsured data, in bytes, that the network agrees to transfer, during the measurement interval from destination to source.
1.3.6.1.4.1.711.2.1.8.4.1.1.36INTEGERread-onlymandatory
ffCktOperPrinBwType
OBJECT-TYPE
This variable indicates the type of service supported on primary portion of this Virtual Circuit.
1.3.6.1.4.1.711.2.1.8.4.1.1.37INTEGER {guaranteed(1), insured(2)}read-onlymandatory
ffCktAdminPrinBwType
OBJECT-TYPE
This variable indicates the type of service supported on primary portion of this Virtual Circuit. This variable takes effect when ffCktStatus is set.
1.3.6.1.4.1.711.2.1.8.4.1.1.38INTEGER {guaranteed(1), insured(2)}read-writemandatory
ffCktOperTransPri
OBJECT-TYPE
This variable indicates the transfer priority supported on this Virtual Circuit.
1.3.6.1.4.1.711.2.1.8.4.1.1.39INTEGER (0..1)read-onlymandatory
ffCktAdminTransPri
OBJECT-TYPE
This variable indicates the transfer priority supported on this Virtual Circuit. This variable takes effect when ffCktStatus is set.
1.3.6.1.4.1.711.2.1.8.4.1.1.40INTEGER (0..1)read-writemandatory
ffCktStatus
OBJECT-TYPE
This variable indicates the Status of this Virtual Circuit. It may be enabled or disabled. In order to modify a Virtual Circuit, the new desired variables should be modified and then this variable should be set (or set again) to enabled. At that time desired variables will become the actual variables. To remove a PVC, set its status to delete. By default, if not configured when creating the entry, the status is disabled.
1.3.6.1.4.1.711.2.1.8.4.1.1.99INTEGER {enabled(1), disabled(2), delete(3)}read-writemandatory
ffCktInfoTable
OBJECT-TYPE
A table containing information about specific Frame Forwarding virtual circuits.
1.3.6.1.4.1.711.2.1.8.4.2not-accessiblemandatory
ffCktInfoEntry
OBJECT-TYPE
The information regarding a single Data Link Connection Identifier.
1.3.6.1.4.1.711.2.1.8.4.2.1not-accessiblemandatory
ffCktInfoIfIndex
OBJECT-TYPE
The ifIndex Value of the ifEntry this virtual circuit is layered onto. See above comments to calculate ifIndex.
1.3.6.1.4.1.711.2.1.8.4.2.1.1INTEGERread-onlymandatory
ffCktInfoDownstreamState
OBJECT-TYPE
This variable indicates the state of the downstream half of the circuit. (passing data from the local port to the remote end of the network)
1.3.6.1.4.1.711.2.1.8.4.2.1.2INTEGER {active(1), inactive(2)}read-onlymandatory
ffCktInfoUpstreamState
OBJECT-TYPE
This variable indicates the state of the upstream half of the circuit. (passing data from the port at the remote end of the network to the local port)
1.3.6.1.4.1.711.2.1.8.4.2.1.3INTEGER {active(1), inactive(2)}read-onlymandatory
ffCktInfoCallIDIncoming
OBJECT-TYPE
This variable indicates the Call Identifier assigned to the incomming half of this circuit.
1.3.6.1.4.1.711.2.1.8.4.2.1.4INTEGERread-onlymandatory
ffCktInfoCallIDOutgoing
OBJECT-TYPE
This variable indicates the Call Identifier assigned to the outgoing half of this circuit.
1.3.6.1.4.1.711.2.1.8.4.2.1.5INTEGERread-onlymandatory
ffCktInfoLastAtmErr
OBJECT-TYPE
This variable indicates the last error, if any, returned by the Atm Connection Management layer when an attempt was made to create a connection or flow.
1.3.6.1.4.1.711.2.1.8.4.2.1.6OCTET STRINGread-onlymandatory
ffCktInfoDataCellsRequired
OBJECT-TYPE
This variable indicates the bandwidth in cells needed to establish this VC. The value returned combines the committed and the Secondary bandwidth needs.
1.3.6.1.4.1.711.2.1.8.4.2.1.7INTEGERread-onlymandatory
ffCktInfoLastAtmLocation
OBJECT-TYPE
This variable indicates the last error, if any, returned by the Atm Connection Management layer when an attempt was made to create a connection or flow. The format of the string is: nodenum:ifIndex where all numbers are specified in decimal. For example 5142:6000 refers to the remote endpoint with node 5142, ifIndex 6000 (slot 6 port 0 frType 0).
1.3.6.1.4.1.711.2.1.8.4.2.1.8DisplayString (SIZE(0..30))read-onlymandatory
sUniCktInfo
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.8.5
sUniCktCfgTable
OBJECT-TYPE
A table containing information about specific VCIs and corresponding circuits.
1.3.6.1.4.1.711.2.1.8.5.1not-accessiblemandatory
sUniCktEntry
OBJECT-TYPE
The information regarding a single Data Link Connection Identifier.
1.3.6.1.4.1.711.2.1.8.5.1.1not-accessiblemandatory
sUniCktSrcNode
OBJECT-TYPE
The Node Identifier for the source end of this virtual circuit.
1.3.6.1.4.1.711.2.1.8.5.1.1.1INTEGERread-onlymandatory
sUniCktSrcIfIndex
OBJECT-TYPE
The ifIndex Value of the ifEntry this virtual circuit is layered onto. See above comments to calculate ifIndex.
1.3.6.1.4.1.711.2.1.8.5.1.1.2INTEGERread-onlymandatory
sUniCktSrcVCI
OBJECT-TYPE
The Data Link Connection Identifier for this virtual circuit.
1.3.6.1.4.1.711.2.1.8.5.1.1.3VCIread-onlymandatory
sUniCktAdminDestNode
OBJECT-TYPE
The Node Identifier for the Destination end of this virtual circuit. This variable takes effect when sUniCktSts is set.
1.3.6.1.4.1.711.2.1.8.5.1.1.10INTEGERread-writemandatory
sUniCktOperDestNode
OBJECT-TYPE
The Node Identifier for the Destination end of this virtual circuit.
1.3.6.1.4.1.711.2.1.8.5.1.1.11INTEGERread-onlymandatory
sUniCktAdminDestIfIndex
OBJECT-TYPE
The ifIndex Value of the ifEntry this virtual circuit is layered onto. See above comments to calculate ifIndex. This variable takes effect when sUniCktSts is set.
1.3.6.1.4.1.711.2.1.8.5.1.1.12INTEGERread-writemandatory
sUniCktOperDestIfIndex
OBJECT-TYPE
The ifIndex Value of the ifEntry this virtual circuit is layered onto. See above comments to calculate ifIndex.
1.3.6.1.4.1.711.2.1.8.5.1.1.13INTEGERread-onlymandatory
sUniCktAdminDestVCI
OBJECT-TYPE
The Data Link Connection Identifier for this virtual circuit. This variable takes effect when sUniCktSts is set.
1.3.6.1.4.1.711.2.1.8.5.1.1.14VCIread-writemandatory
sUniCktOperDestVCI
OBJECT-TYPE
The Data Link Connection Identifier for this virtual circuit.
1.3.6.1.4.1.711.2.1.8.5.1.1.15VCIread-onlymandatory
sUniCktOperPrinBwType
OBJECT-TYPE
This variable indicates the type of service supported on primary portion of this Virtual Circuit.
1.3.6.1.4.1.711.2.1.8.5.1.1.22INTEGER {guaranteed(1), insured(2)}read-onlymandatory
sUniCktAdminPrinBwType
OBJECT-TYPE
This variable indicates the type of service supported on primary portion of this Virtual Circuit. This variable takes effect when sUniCktSts is set.
1.3.6.1.4.1.711.2.1.8.5.1.1.23INTEGER {guaranteed(1), insured(2)}read-writemandatory
sUniCktOperTransPri
OBJECT-TYPE
This variable indicates the transfer priority supported on this Virtual Circuit.
1.3.6.1.4.1.711.2.1.8.5.1.1.24INTEGER (0..1)read-onlymandatory
sUniCktAdminTransPri
OBJECT-TYPE
This variable indicates the transfer priority supported on this Virtual Circuit. This variable takes effect when sUniCktSts is set.
1.3.6.1.4.1.711.2.1.8.5.1.1.25INTEGER (0..1)read-writemandatory
sUniCktAdminSrcInsuredRate
OBJECT-TYPE
This variable, the Insured Rate is the rate of insured data that the network commits to supporting under normal network conditions from source to destination. This is specified in cells per second. This variable takes effect when sUniCktSts is set.
1.3.6.1.4.1.711.2.1.8.5.1.1.26INTEGERread-writemandatory
sUniCktOperSrcInsuredRate
OBJECT-TYPE
This variable, the Insured Rate is the rate of insured data that the network commits to supporting under normal network conditions from source to destination. This is specified in cells per second.
1.3.6.1.4.1.711.2.1.8.5.1.1.27INTEGERread-onlymandatory
sUniCktAdminSrcInsuredBurst
OBJECT-TYPE
This variable indicates the Insured Burst Size, which is the amount of insured data, in cells, that the network agrees to transfer under normal conditions, during the measurement interval from source to destination. This variable takes effect when sUniCktSts is set.
1.3.6.1.4.1.711.2.1.8.5.1.1.28INTEGERread-writemandatory
sUniCktOperSrcInsuredBurst
OBJECT-TYPE
This variable indicates the Insured Burst Size, which is the amount of insured data, in cells, that the network agrees to transfer under normal conditions, during the measurement interval from source to destination.
1.3.6.1.4.1.711.2.1.8.5.1.1.29INTEGERread-onlymandatory
sUniCktAdminSrcMaxRate
OBJECT-TYPE
This variable, the maximum rate is the the total amount of insured plus uninsured data throughput that the network attempts to support under normal network conditions from destination to source. This is specified in cells per second. This variable takes effect when sUniCktSts is set.
1.3.6.1.4.1.711.2.1.8.5.1.1.30INTEGERread-writemandatory
sUniCktOperSrcMaxRate
OBJECT-TYPE
This variable, the maximum rate is the the total amount of insured plus uninsured data throughput that the network attempts to support under normal network conditions from destination to source. This is specified in cells per second.
1.3.6.1.4.1.711.2.1.8.5.1.1.31INTEGERread-onlymandatory
sUniCktAdminSrcMaxBurst
OBJECT-TYPE
This variable is the maximum Burst Size, the maximum amount of insured plus uninsured data, in cells, that the network will attempt to deliver over the measurement interval from the Source to the Destination. This variable takes effect when sUniCktSts is set.
1.3.6.1.4.1.711.2.1.8.5.1.1.32INTEGERread-writemandatory
sUniCktOperSrcMaxBurst
OBJECT-TYPE
This variable indicates the maximum Burst Size, the maximum amount of insured plus uninsured cells, that the network will attempt to deliver over the measurement interval from the Source to the Destination.
1.3.6.1.4.1.711.2.1.8.5.1.1.33INTEGERread-onlymandatory
sUniCktAdminDestInsuredRate
OBJECT-TYPE
This variable, the Insured Rate is the rate of insured data that the network commits to supporting under normal network conditions from destination to source. This is specified in cells per second. This variable takes effect when sUniCktSts is set.
1.3.6.1.4.1.711.2.1.8.5.1.1.34INTEGERnot-accessiblemandatory
sUniCktOperDestInsuredRate
OBJECT-TYPE
This variable, the Insured Rate, is the rate of insured data that the network commits to supporting under normal network conditions from destination to source. This is specified in cells per second.
1.3.6.1.4.1.711.2.1.8.5.1.1.35INTEGERread-onlymandatory
sUniCktAdminDestInsuredBurst
OBJECT-TYPE
This variable indicates the Insured Burst Size, which is the amount of insured data, in cells, that the network agrees to transfer under normal conditions, during the measurement interval from destination to source. This variable takes effect when sUniCktSts is set.
1.3.6.1.4.1.711.2.1.8.5.1.1.36INTEGERnot-accessiblemandatory
sUniCktOperDestInsuredBurst
OBJECT-TYPE
This variable indicates the Insured Burst Size, which is the amount of insured data, in cells, that the network agrees to transfer under normal conditions, during the measurement interval from destination to source.
1.3.6.1.4.1.711.2.1.8.5.1.1.37INTEGERread-onlymandatory
sUniCktAdminDestMaxRate
OBJECT-TYPE
This variable, the maximum rate is the the total amount of insured plus uninsured data throughput that the network attempts to support under normal network conditions from destination to source. This is specified in cells per second. This variable takes effect when sUniCktSts is set.
1.3.6.1.4.1.711.2.1.8.5.1.1.38INTEGERnot-accessiblemandatory
sUniCktOperDestMaxRate
OBJECT-TYPE
This variable, the maximum rate is the the total amount of insured plus uninsured data throughput that the network attempts to support under normal network conditions from destination to source. This is specified in cells per second.
1.3.6.1.4.1.711.2.1.8.5.1.1.39INTEGERread-onlymandatory
sUniCktAdminDestMaxBurst
OBJECT-TYPE
This variable is the maximum Burst Size, the maximum amount of insured plus uninsured cells that the network will attempt to deliver over the measurement interval from the Destination to the Source. This variable takes effect when sUniCktSts is set.
1.3.6.1.4.1.711.2.1.8.5.1.1.40INTEGERnot-accessiblemandatory
sUniCktOperDestMaxBurst
OBJECT-TYPE
This variable indicates the maximum Burst Size, the maximum amount of insured plus uninsured cells that the network will attempt to deliver over the measurement interval from the Destination to the Source.
1.3.6.1.4.1.711.2.1.8.5.1.1.41INTEGERread-onlymandatory
sUniCktAdminSecondaryScale
OBJECT-TYPE
Secondary bandwidth scaling factor. This is used to scale down the actual amount of bandwidth to allocate for the Secondary portion of a VC's bandwidth. This is specified as a codepoint as follows: Codepoints Meaning Comment - ---------- ------- ------- 0 - 100 x / 100 e.g., 1 => .01 101 - 109 x - 100 / 1000 e.g., 101 => .001 254 (reserved) 255 (per-port dflt)
1.3.6.1.4.1.711.2.1.8.5.1.1.42INTEGERread-writemandatory
sUniCktOperSecondaryScale
OBJECT-TYPE
Operational version of the Secondary bandwidth scaling factor. This is used to scale down the actual amount of bandwidth to allocate for the Secondary portion of a VC's bandwidth. This is specified as a codepoint as follows: Codepoints Meaning Comment - ---------- ------- ------- 0 - 100 x / 100 e.g., 1 => .01 101 - 109 x - 100 / 1000 e.g., 101 => .001 254 (reserved) 255 (per-port dflt)
1.3.6.1.4.1.711.2.1.8.5.1.1.43INTEGERread-onlymandatory
sUniCktSts
OBJECT-TYPE
This variable indicates the Status of this Virtual Circuit. It may be enabled or disabled. In order to modify a Virtual Circuit, the new desired variables should be modified and then this variable should be set (or set again) to enabled. At that time desired variables will become the actual variables. To remove a PVC, set its status to delete. By default, if not configured when creating the entry, the status is disabled.
1.3.6.1.4.1.711.2.1.8.5.1.1.99INTEGER {enabled(1), disabled(2), delete(3)}read-writemandatory
sUniCktInfoTable
OBJECT-TYPE
A table containing information about specific VCIs and corresponding circuits.
1.3.6.1.4.1.711.2.1.8.5.2not-accessiblemandatory
sUniCktInfoEntry
OBJECT-TYPE
The information regarding a single Data Link Connection Identifier.
1.3.6.1.4.1.711.2.1.8.5.2.1not-accessiblemandatory
sUniCktInfoIfIndex
OBJECT-TYPE
The ifIndex Value of the ifEntry this virtual circuit is layered onto. See above comments to calculate ifIndex.
1.3.6.1.4.1.711.2.1.8.5.2.1.1INTEGERread-onlymandatory
sUniCktInfoVCI
OBJECT-TYPE
The Data Link Connection Identifier for this virtual circuit.
1.3.6.1.4.1.711.2.1.8.5.2.1.2VCIread-onlymandatory
sUniCktInfoUniToNetCallID
OBJECT-TYPE
This variable indicates the Call Identifier assigned to the incomming half of this circuit.
1.3.6.1.4.1.711.2.1.8.5.2.1.3INTEGERread-onlymandatory
sUniCktInfoNetToUniCallID
OBJECT-TYPE
This variable indicates the Call Identifier assigned to the outgoing half of this circuit.
1.3.6.1.4.1.711.2.1.8.5.2.1.4INTEGERread-onlymandatory
sUniCktInfoUniToNetState
OBJECT-TYPE
This variable indicates the state of the UniToNet half of the circuit. (passing data from the local port to the remote end of the network)
1.3.6.1.4.1.711.2.1.8.5.2.1.5INTEGER {active(1), inactive(2)}read-onlymandatory
sUniCktInfoNetToUniState
OBJECT-TYPE
This variable indicates the state of the NetToUni half of the circuit. (passing data from the port at the remote end of the network to the local port)
1.3.6.1.4.1.711.2.1.8.5.2.1.6INTEGER {active(1), inactive(2)}read-onlymandatory
sUniCktInfoLastAtmErr
OBJECT-TYPE
This variable indicates the last error, if any, returned by the Atm Connection Management layer when an attempt was made to create a connection or flow.
1.3.6.1.4.1.711.2.1.8.5.2.1.7OCTET STRINGread-onlymandatory
sUniCktInfoDataCellsRequired
OBJECT-TYPE
This variable indicates the bandwidth in cells needed to establish this VC. The value returned combines the committed and the Secondary bandwidth needs.
1.3.6.1.4.1.711.2.1.8.5.2.1.8INTEGERread-onlymandatory
sUniCktInfoLastAtmLocation
OBJECT-TYPE
This variable indicates the last error, if any, returned by the Atm Connection Management layer when an attempt was made to create a connection or flow. The format of the string is: nodenum:ifIndex where all numbers are specified in decimal. For example 5142:6000 refers to the remote endpoint with node 5142, ifIndex 6000 (slot 6 port 0 frType 0).
1.3.6.1.4.1.711.2.1.8.5.2.1.9DisplayString (SIZE(0..30))read-onlymandatory
pvcInfo
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.8.6
pvcCfgTable
OBJECT-TYPE
A table containing information about specific PVCs.
1.3.6.1.4.1.711.2.1.8.6.1not-accessiblemandatory
pvcEntry
OBJECT-TYPE
The information regarding a single PVC.
1.3.6.1.4.1.711.2.1.8.6.1.1not-accessiblemandatory
pvcSrcIfIndex
OBJECT-TYPE
The ifIndex Value of the ifEntry this virtual circuit is layered onto. See above comments to calculate ifIndex.
1.3.6.1.4.1.711.2.1.8.6.1.1.1INTEGERread-onlymandatory
pvcSrcPvcId
OBJECT-TYPE
The local PVC Connection Identifier for this virtual circuit.
1.3.6.1.4.1.711.2.1.8.6.1.1.2INTEGERread-onlymandatory
pvcSrcNode
OBJECT-TYPE
The Node Identifier for the source end of this virtual circuit.
1.3.6.1.4.1.711.2.1.8.6.1.1.3INTEGERread-onlymandatory
pvcSrcInsuredRate
OBJECT-TYPE
This variable, the Insured Rate is the rate of insured data that the network commits to supporting under normal network conditions from Source to Destination. It is specified in bits per second. This variable takes effect when pvcStatus is set. This variable may not be modified unless pvcStatus is set to disabled.
1.3.6.1.4.1.711.2.1.8.6.1.1.4INTEGERread-writemandatory
pvcSrcInsuredBurst
OBJECT-TYPE
This variable indicates the Insured Burst Size, which is the amount of insured data, in bytes, that the network agrees to transfer under normal conditions, during the measurement interval from source to destination. This variable takes effect when pvcStatus is set. This variable may not be modified unless pvcStatus is set to disabled.
1.3.6.1.4.1.711.2.1.8.6.1.1.5INTEGERread-writemandatory
pvcSrcMaxRate
OBJECT-TYPE
This variable, the Maximum Rate is the the maximum amount of insured plus uninsured data throughput that the network agrees to support from source to destination. It is specified in bits per second. This variable takes effect when pvcStatus is set. This variable may not be modified unless pvcStatus is set to disabled.
1.3.6.1.4.1.711.2.1.8.6.1.1.6INTEGERread-writemandatory
pvcSrcMaxBurst
OBJECT-TYPE
This variable indicates the Total Burst Size, which is the maximum amount of insured plus uninsured data bytes that the network will at- tempt to deliver over the measurement interval from the Source to the Destination. This variable takes effect when pvcStatus is set. This variable may not be modified unless pvcStatus is set to disabled.
1.3.6.1.4.1.711.2.1.8.6.1.1.7INTEGERread-writemandatory
pvcSecondaryScale
OBJECT-TYPE
Secondary bandwidth scaling factor. This is used to scale down the actual amount of bandwidth to allocate for the Secondary portion of a VC's bandwidth. This is specified as a codepoint as follows: Codepoints Meaning Comment - ---------- ------- ------- 0 - 100 x / 100 e.g., 1 => .01 101 - 109 x - 100 / 1000 e.g., 101 => .001 254 (reserved) 255 (per-port dflt)
1.3.6.1.4.1.711.2.1.8.6.1.1.8INTEGERread-writemandatory
pvcPrinBwType
OBJECT-TYPE
This variable indicates the type of service supported on primary portion of this Virtual Circuit. This variable takes effect when pvcStatus is set. This variable may not be modified unless pvcStatus is set to disabled.
1.3.6.1.4.1.711.2.1.8.6.1.1.9INTEGER {guaranteed(1), insured(2)}read-writemandatory
pvcTransPri
OBJECT-TYPE
This variable indicates the transfer priority supported on this Virtual Circuit. This variable takes effect when pvcStatus is set. This variable may not be modified unless pvcStatus is set to disabled.
1.3.6.1.4.1.711.2.1.8.6.1.1.10INTEGER (0..1)read-writemandatory
pvcUserDataPerCell
OBJECT-TYPE
User data bits per cell, specifies the expected packing efficiency when frames are converted to cells. It does not affect the actual packing of data into cells but serves as an estimate on which bandwidth allocation and other connection related functions will be based. This variable takes effect when pvcStatus is set. This variable may not be modified unless pvcStatus is set to disabled.
1.3.6.1.4.1.711.2.1.8.6.1.1.11INTEGER (0..384)read-writemandatory
pvcStatus
OBJECT-TYPE
This variable indicates the Status of this Virtual Circuit. It may be enabled or disabled. In order to modify a Virtual Circuit, the new desired variables should be modified and then this variable should be set (or set again) to enabled. At that time desired variables will become the actual variables. To remove a PVC, set its status to delete. By default, if not configured when creating the entry, the status is disabled.
1.3.6.1.4.1.711.2.1.8.6.1.1.99INTEGER {enabled(1), disabled(2), delete(3)}read-writemandatory
mcEndptInfo
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.8.7
mcEndptCfgTable
OBJECT-TYPE
A table containing information about specific endpoints and corresponding circuits.
1.3.6.1.4.1.711.2.1.8.7.1not-accessiblemandatory
mcEndptEntry
OBJECT-TYPE
The information regarding a single endpoint.
1.3.6.1.4.1.711.2.1.8.7.1.1not-accessiblemandatory
mcEndptLclIfIndex
OBJECT-TYPE
The ifIndex Value of the ifEntry this virtual circuit is layered onto. See above comments to calculate ifIndex.
1.3.6.1.4.1.711.2.1.8.7.1.1.1INTEGERread-onlymandatory
mcEndptLclCktid
OBJECT-TYPE
The Local Circuit Identifier for this virtual circuit.
1.3.6.1.4.1.711.2.1.8.7.1.1.2INTEGERread-onlymandatory
mcEndptLclInstance
OBJECT-TYPE
A Locally significant index used to separate the different remote endpoints for this multicast virtual circuit.
1.3.6.1.4.1.711.2.1.8.7.1.1.3INTEGERread-onlymandatory
mcEndptDest
OBJECT-TYPE
The Destination for this segment of the multicast virtual circuit. The format of the string is: nodenum:ifIndex:cktID where all numbers are specified in decimal. For example 5142:6000:16 refers to the remote endpoint with node 5142, ifIndex 6000 (slot 6 port 0 frType 0), and circuit identifier 16. This variable cannot be modified while mcEndptStatus is set to active.
1.3.6.1.4.1.711.2.1.8.7.1.1.4DisplayString (SIZE(0..30))read-writemandatory
mcEndptServiceType
OBJECT-TYPE
This variable is provided for future expansion, to allow creation of VCs between dissimilar protocols. This variable cannot be modified while mcEndptStatus is set to active.
1.3.6.1.4.1.711.2.1.8.7.1.1.5INTEGERread-writemandatory
mcEndptRmtVCstatus
OBJECT-TYPE
This variable indicates the remote state of the circuit. For FR this would be the LMI status.
1.3.6.1.4.1.711.2.1.8.7.1.1.6INTEGER {active(1), inactive(2)}read-onlymandatory
mcEndptCallIDIncoming
OBJECT-TYPE
This variable indicates the Call Identifier assigned to the incomming (from the net) direction of this circuit.
1.3.6.1.4.1.711.2.1.8.7.1.1.7INTEGERread-onlymandatory
mcEndptDownstreamState
OBJECT-TYPE
This variable indicates the state of the downstream direction of the circuit. (passing data from the local port to the remote end of the network)
1.3.6.1.4.1.711.2.1.8.7.1.1.8INTEGER {active(1), inactive(2)}read-onlymandatory
mcEndptUpstreamState
OBJECT-TYPE
This variable indicates the state of the upstream direction of the circuit. (passing data from the port at the remote end of the network to the local port)
1.3.6.1.4.1.711.2.1.8.7.1.1.9INTEGER {active(1), inactive(2)}read-onlymandatory
mcEndptLastAtmErr
OBJECT-TYPE
This variable indicates the last error, if any, returned by the Atm Connection Management layer when an attempt was made to create a connection or flow.
1.3.6.1.4.1.711.2.1.8.7.1.1.10OCTET STRINGread-onlymandatory
mcEndptLastAtmLocation
OBJECT-TYPE
This variable indicates the last error, if any, returned by the Atm Connection Management layer when an attempt was made to create a connection or flow. The format of the string is: nodenum:ifIndex where all numbers are specified in decimal. For example 5142:6000 refers to the remote endpoint with node 5142, ifIndex 6000 (slot 6 port 0 frType 0).
1.3.6.1.4.1.711.2.1.8.7.1.1.11DisplayString (SIZE(0..30))read-onlymandatory
mcEndptStatus
OBJECT-TYPE
This variable indicates the Status of this Virtual Circuit. It may be enabled or disabled. In order to modify a Virtual Circuit, the new desired variables should be modified and then this variable should be set (or set again) to enabled. At that time desired variables will become the operational (or in-use) variables. To remove a PVC, set its status to delete. By default, if not configured when creating the entry, the status is disabled. An existing instance of this object cannot be set to createRequest(4). This object may only be set to createRequest(4) when this instance is created. When this object is created, the agent may wish to create supplemental object instances to complete a conceptual row in this table. Immediately after completing the create operation, the agent must set this object to underCreation(5). Entries shall exist in the underCreation(5) state until the management station is finished configuring the entry and sets this object to active(1), inactive(2), or aborts, setting this object to delete(4). If the agent determines that an entry has been in the underCreation(5) state for an abnormally long time, it may decide that the management station has become unavailable. If the agent makes this decision, it may set this object to delete(3) to reclaim the entry. A prudent agent will understand that the management station may need to wait for human input and will allow for that possibility in its determination of this abnormally long period.
1.3.6.1.4.1.711.2.1.8.7.1.1.99INTEGER {enabled(1), disabled(2), delete(3), createRequest(4), underCreation(5)}read-writemandatory
lsPrivate
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.10
lsExperimental
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.11
lsExperimentalStatistics
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.11.1
lsEdgeStatistics
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.11.1.1
lsEdgeStatTable
OBJECT-TYPE
Edge Card specific statistics subset information
1.3.6.1.4.1.711.2.1.11.1.1.1not-accessiblemandatory
lsEdgeStatEntry
OBJECT-TYPE
An entry in Edge Card Statistics Table.
1.3.6.1.4.1.711.2.1.11.1.1.1.1not-accessiblemandatory
edgeStatIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.11.1.1.1.1.1INTEGERread-onlymandatory
edgeStatFsuRATOs
OBJECT-TYPE
The total number of Reassembly TimeOuts detected by the FSU
1.3.6.1.4.1.711.2.1.11.1.1.1.1.2Counterread-onlymandatory
edgeStatFsuRATOLastInfo
OBJECT-TYPE
Header Information related to the last RATO (Port/VCI minimum)
1.3.6.1.4.1.711.2.1.11.1.1.1.1.3INTEGERread-onlymandatory
edgeStatTsuHoldQCells
OBJECT-TYPE
The total number of cells in hold queues
1.3.6.1.4.1.711.2.1.11.1.1.1.1.4Gaugeread-onlymandatory
edgeStatTsuHoldQs
OBJECT-TYPE
The total number of active hold queues
1.3.6.1.4.1.711.2.1.11.1.1.1.1.5Gaugeread-onlymandatory
tluAAL5XsumErrs
OBJECT-TYPE
Number of AAL5 Xsum errors detected by the TLU. Availability may depend on HW type, such as ASIC HW.
1.3.6.1.4.1.711.2.1.11.1.1.1.1.6Counterread-onlymandatory
tluAAL5AbortErrs
OBJECT-TYPE
Number of AAL5 Abort errors (zero length) detected by the TLU. Availability may depend on HW type, such as ASIC HW.
1.3.6.1.4.1.711.2.1.11.1.1.1.1.7Counterread-onlymandatory
tluAAL5ErrLastVci
OBJECT-TYPE
Contains the 16-bit VCI index corresponding to the last AAL5 Xsum or Abort error, along with the port number. Format TBD. Availability may depend on HW type, such as ASIC HW.
1.3.6.1.4.1.711.2.1.11.1.1.1.1.8INTEGERread-onlymandatory
lsEdgePortStatTable
OBJECT-TYPE
Edge Card specific statistics subset information
1.3.6.1.4.1.711.2.1.11.1.1.2not-accessiblemandatory
lsEdgePortStatEntry
OBJECT-TYPE
An entry in Edge Port Statistics Table.
1.3.6.1.4.1.711.2.1.11.1.1.2.1not-accessiblemandatory
edgePortStatIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.11.1.1.2.1.1INTEGERread-onlymandatory
edgePortRcvOctets
OBJECT-TYPE
Number of octets received regardless of error status
1.3.6.1.4.1.711.2.1.11.1.1.2.1.2Counterread-onlymandatory
edgePortXmtOctets
OBJECT-TYPE
Number of octets transmitted regardless of error status
1.3.6.1.4.1.711.2.1.11.1.1.2.1.3Counterread-onlymandatory
edgePortFsuCksmErrMsgs
OBJECT-TYPE
The number of messages with AAL5 checksum errors detected by FSU. May not be provided on a per-port basis in all HW.
1.3.6.1.4.1.711.2.1.11.1.1.2.1.4Counterread-onlymandatory
edgePortCksmErrLastVci
OBJECT-TYPE
The last Vci index associated with a AAL5 checksum error. May not be provided on a per-port basis in all HW.
1.3.6.1.4.1.711.2.1.11.1.1.2.1.5INTEGERread-onlymandatory
edgePortDownXmtFrames
OBJECT-TYPE
The number of messages received by the TSU for which the the VCI was not configured.
1.3.6.1.4.1.711.2.1.11.1.1.2.1.6Counterread-onlymandatory
edgePortRcvUcastPkts
OBJECT-TYPE
Number of Unicast packets received. Availability may depend on HW type, such as ASIC HW.
1.3.6.1.4.1.711.2.1.11.1.1.2.1.7Counterread-onlymandatory
edgePortRcvNUcastPkts
OBJECT-TYPE
Number of Non-Unicast packets received. Availability may depend on HW type, such as ASIC HW.
1.3.6.1.4.1.711.2.1.11.1.1.2.1.8Counterread-onlymandatory
edgePortXmtUcastPkts
OBJECT-TYPE
Number of Unicast packets transmitted. Availability may depend on HW type, such as ASIC HW.
1.3.6.1.4.1.711.2.1.11.1.1.2.1.9Counterread-onlymandatory
edgePortXmtNUcastPkts
OBJECT-TYPE
Number of Non-Unicast packets transmitted. Availability may depend on HW type, such as ASIC HW.
1.3.6.1.4.1.711.2.1.11.1.1.2.1.10Counterread-onlymandatory
edgePortRcvSmplPktSize
OBJECT-TYPE
Number of octets for the last sampled from-port packet, including overhead octets. Used as a substitute for the frame size histogram when the histogram is not available. Availability may depend on HW type, such as ASIC HW. Sampling algorithm to be determined.
1.3.6.1.4.1.711.2.1.11.1.1.2.1.11Gaugeread-onlymandatory
edgePortXmtSmplPktSize
OBJECT-TYPE
Number of octets for the last sampled to-port packet, including overhead octets. Used as a substitute for the frame size histogram when the histogram is not available. Availability may depend on HW type, such as ASIC HW. Sampling algorithm to be determined.
1.3.6.1.4.1.711.2.1.11.1.1.2.1.12Gaugeread-onlymandatory
edgePortRcvL3XsumErrs
OBJECT-TYPE
Number of L3 packets processed with a Level 3 checksum error. Availability may depend on HW type, such as ASIC HW.
1.3.6.1.4.1.711.2.1.11.1.1.2.1.13Counterread-onlymandatory
edgePortRcvL3XsumErrLastVci
OBJECT-TYPE
Last 15-bit VCI index associated with a Level 3 checksum error. Availability may depend on HW type, such as ASIC HW.
1.3.6.1.4.1.711.2.1.11.1.1.2.1.14INTEGERread-onlymandatory
edgePortRcvCRCErrors
OBJECT-TYPE
The number of messages received by the port with CRC errors.
1.3.6.1.4.1.711.2.1.11.1.1.2.1.15Counterread-onlymandatory
edgePortRcvAborts
OBJECT-TYPE
The number of aborts detected by the HW.
1.3.6.1.4.1.711.2.1.11.1.1.2.1.16Counterread-onlymandatory
edgePortXmtUnderflows
OBJECT-TYPE
The number of underflow events detected by I/O hardware.
1.3.6.1.4.1.711.2.1.11.1.1.2.1.17Counterread-onlymandatory
edgePortRcvShortFrames
OBJECT-TYPE
The number of short incoming frames detected by L2
1.3.6.1.4.1.711.2.1.11.1.1.2.1.18Counterread-onlymandatory
lsFrameRelayDlciStatTable
OBJECT-TYPE
FrameRelay Port/DLCI specific statistics subset information
1.3.6.1.4.1.711.2.1.11.1.1.3not-accessiblemandatory
lsFrameRelayDlciStatEntry
OBJECT-TYPE
An entry in the FrameRelay Port/Dlci Statistics Table.
1.3.6.1.4.1.711.2.1.11.1.1.3.1not-accessiblemandatory
frameRelayDlciStatPortIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.11.1.1.3.1.1INTEGERread-onlymandatory
frameRelayDlciStatDlciIndex
OBJECT-TYPE
Unique Dlci identifier for indicated port
1.3.6.1.4.1.711.2.1.11.1.1.3.1.2INTEGERread-onlymandatory
frameRelayDlciToSwCLP0Frames
OBJECT-TYPE
Number of Frames forwarded to TSU with CLP=0
1.3.6.1.4.1.711.2.1.11.1.1.3.1.3Counterread-onlymandatory
frameRelayDlciToSwCLP0Cells
OBJECT-TYPE
Number of Cells forwarded to TSU with CLP=0
1.3.6.1.4.1.711.2.1.11.1.1.3.1.4Counterread-onlymandatory
frameRelayDlciToSwCLP1Frames
OBJECT-TYPE
Number of Frames forwarded to TSU with CLP=1
1.3.6.1.4.1.711.2.1.11.1.1.3.1.5Counterread-onlymandatory
frameRelayDlciToSwCLP1Cells
OBJECT-TYPE
Number of Cells forwarded to TSU with CLP=1
1.3.6.1.4.1.711.2.1.11.1.1.3.1.6Counterread-onlymandatory
frameRelayDlciToSwDiscardFrames
OBJECT-TYPE
Number of to-switch Frames discarded due to excessive traffic according to the Usage Parameter Descriptor for this Dlci
1.3.6.1.4.1.711.2.1.11.1.1.3.1.7Counterread-onlymandatory
frameRelayDlciToSwDiscardCells
OBJECT-TYPE
Number of to-switch Cells discarded due to excessive traffic according to the Usage Parameter Descriptor for this Dlci
1.3.6.1.4.1.711.2.1.11.1.1.3.1.8Counterread-onlymandatory
frameRelayDlciFrSwCLP0Frames
OBJECT-TYPE
Number of frames received from the switch with CLP=0
1.3.6.1.4.1.711.2.1.11.1.1.3.1.9Counterread-onlymandatory
frameRelayDlciFrSwCLP0Cells
OBJECT-TYPE
Number of cells received from the switch with CLP=0
1.3.6.1.4.1.711.2.1.11.1.1.3.1.10Counterread-onlymandatory
frameRelayDlciFrSwCLP1Frames
OBJECT-TYPE
Number of frames received from the switch with CLP=1
1.3.6.1.4.1.711.2.1.11.1.1.3.1.11Counterread-onlymandatory
frameRelayDlciFrSwCLP1Cells
OBJECT-TYPE
Number of cells received from the switch with CLP=1
1.3.6.1.4.1.711.2.1.11.1.1.3.1.12Counterread-onlymandatory
lsEdgePortToSwMsgLenTable
OBJECT-TYPE
Histogram of incoming message lengths (in cells) by Edge port
1.3.6.1.4.1.711.2.1.11.1.1.4not-accessiblemandatory
lsEdgePortToSwMsgLenEntry
OBJECT-TYPE
An entry in the Edge Port/Incoming-Message-Cell-Length histogram table.
1.3.6.1.4.1.711.2.1.11.1.1.4.1not-accessiblemandatory
edgeToSwMsgLenPortIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.11.1.1.4.1.1INTEGERread-onlymandatory
edgeToSwMsgLenBinIndex
OBJECT-TYPE
Histogram index for the incoming message size in units of network cells
1.3.6.1.4.1.711.2.1.11.1.1.4.1.2INTEGERread-onlymandatory
edgeToSwMsgLenMsgs
OBJECT-TYPE
Count of the number of incoming messages of the given length in units of network cells.
1.3.6.1.4.1.711.2.1.11.1.1.4.1.3Counterread-onlymandatory
lsEdgeSwToPortMsgLenTable
OBJECT-TYPE
Histogram of incoming message lengths (in cells) by Edge port
1.3.6.1.4.1.711.2.1.11.1.1.5not-accessiblemandatory
lsEdgeSwToPortMsgLenEntry
OBJECT-TYPE
An entry in the Edge Port/Outgoing-Message-Cell-Length histogram table.
1.3.6.1.4.1.711.2.1.11.1.1.5.1not-accessiblemandatory
edgeToPortMsgLenPortIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.11.1.1.5.1.1INTEGERread-onlymandatory
edgeToPortMsgLenBinIndex
OBJECT-TYPE
Histogram index for the outgoing message length in units of network cells.
1.3.6.1.4.1.711.2.1.11.1.1.5.1.2INTEGERread-onlymandatory
edgeToPortMsgLenMsgs
OBJECT-TYPE
Count of the number of outgoing messages of the given length in terms of network cells.
1.3.6.1.4.1.711.2.1.11.1.1.5.1.3Counterread-onlymandatory
lsEdgeCpuWorkloadTable
OBJECT-TYPE
Edge Card Workload Statistics Counter Table
1.3.6.1.4.1.711.2.1.11.1.1.6not-accessiblemandatory
lsEdgeCpuWorkloadEntry
OBJECT-TYPE
An entry in the Edge Cpu Workload Table
1.3.6.1.4.1.711.2.1.11.1.1.6.1not-accessiblemandatory
lsEdgeWorkloadCardIndex
OBJECT-TYPE
Unique Edge card Index consisting of slot number.
1.3.6.1.4.1.711.2.1.11.1.1.6.1.1INTEGERread-onlymandatory
lsEdgeWorkloadTypeIndex
OBJECT-TYPE
Index which identifies the Edge CPU Workload Variable
1.3.6.1.4.1.711.2.1.11.1.1.6.1.2INTEGERread-onlymandatory
lsEdgeWorkloadEvents
OBJECT-TYPE
Edge Cpu Workload Counter for the specified Workload Variable
1.3.6.1.4.1.711.2.1.11.1.1.6.1.3Counterread-onlymandatory
lsFrameForwardStatTable
OBJECT-TYPE
FrameForward Port/ specific statistics subset information
1.3.6.1.4.1.711.2.1.11.1.1.7not-accessiblemandatory
lsFrameForwardStatEntry
OBJECT-TYPE
An entry in the FrameForward Port/ Statistics Table.
1.3.6.1.4.1.711.2.1.11.1.1.7.1not-accessiblemandatory
frameForwardStatPortIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.11.1.1.7.1.1INTEGERread-onlymandatory
frameForwardToSwCLP0Frames
OBJECT-TYPE
Number of Frames forwarded to TSU with CLP=0
1.3.6.1.4.1.711.2.1.11.1.1.7.1.2Counterread-onlymandatory
frameForwardToSwCLP0Cells
OBJECT-TYPE
Number of Cells forwarded to TSU with CLP=0
1.3.6.1.4.1.711.2.1.11.1.1.7.1.3Counterread-onlymandatory
frameForwardToSwCLP1Frames
OBJECT-TYPE
Number of Frames forwarded to TSU with CLP=1
1.3.6.1.4.1.711.2.1.11.1.1.7.1.4Counterread-onlymandatory
frameForwardToSwCLP1Cells
OBJECT-TYPE
Number of Cells forwarded to TSU with CLP=1
1.3.6.1.4.1.711.2.1.11.1.1.7.1.5Counterread-onlymandatory
frameForwardToSwDiscardFrames
OBJECT-TYPE
Number of to-switch Frames discarded due to excessive traffic according to the Usage Parameter Descriptor for this
1.3.6.1.4.1.711.2.1.11.1.1.7.1.6Counterread-onlymandatory
frameForwardToSwDiscardCells
OBJECT-TYPE
Number of to-switch Cells discarded due to excessive traffic according to the Usage Parameter Descriptor for this
1.3.6.1.4.1.711.2.1.11.1.1.7.1.7Counterread-onlymandatory
frameForwardFrSwCLP0Frames
OBJECT-TYPE
Number of frames received from the switch with CLP=0
1.3.6.1.4.1.711.2.1.11.1.1.7.1.8Counterread-onlymandatory
frameForwardFrSwCLP0Cells
OBJECT-TYPE
Number of cells received from the switch with CLP=0
1.3.6.1.4.1.711.2.1.11.1.1.7.1.9Counterread-onlymandatory
frameForwardFrSwCLP1Frames
OBJECT-TYPE
Number of frames received from the switch with CLP=1
1.3.6.1.4.1.711.2.1.11.1.1.7.1.10Counterread-onlymandatory
frameForwardFrSwCLP1Cells
OBJECT-TYPE
Number of cells received from the switch with CLP=1
1.3.6.1.4.1.711.2.1.11.1.1.7.1.11Counterread-onlymandatory
lsTrunkStatistics
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.11.1.2
lsTrunkPortStatTable
OBJECT-TYPE
Trunk Card specific statistics subset information
1.3.6.1.4.1.711.2.1.11.1.2.1not-accessiblemandatory
lsTrunkPortStatEntry
OBJECT-TYPE
An entry in Trunk Port Statistics Table.
1.3.6.1.4.1.711.2.1.11.1.2.1.1not-accessiblemandatory
trunkPortStatIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.11.1.2.1.1.1INTEGERread-onlymandatory
trunkPortRcvCells
OBJECT-TYPE
Number of cells received regardless of error status
1.3.6.1.4.1.711.2.1.11.1.2.1.1.2Counterread-onlymandatory
trunkPortXmtCells
OBJECT-TYPE
Number of cells transmitted regardless of error status
1.3.6.1.4.1.711.2.1.11.1.2.1.1.3Counterread-onlymandatory
trunkPortRcvRuns
OBJECT-TYPE
The number of runs of cells received. A Run is a sequence of Non-Null Cells bounded by Null Cells.
1.3.6.1.4.1.711.2.1.11.1.2.1.1.4Counterread-onlymandatory
trunkPortDownXmtCells
OBJECT-TYPE
The number of cells received by the TSU for which the the VCI was not configured.
1.3.6.1.4.1.711.2.1.11.1.2.1.1.5Counterread-onlymandatory
trunkPortRcvCRCErrors
OBJECT-TYPE
The number of messages received by the port with CRC errors.
1.3.6.1.4.1.711.2.1.11.1.2.1.1.6Counterread-onlymandatory
trunkPortRcvAborts
OBJECT-TYPE
The number of aborts detected by the HW.
1.3.6.1.4.1.711.2.1.11.1.2.1.1.7Counterread-onlymandatory
trunkPortXmtUnderflows
OBJECT-TYPE
The number of underflow events detected by I/O hardware.
1.3.6.1.4.1.711.2.1.11.1.2.1.1.8Counterread-onlymandatory
trunkPortRcvShortFrames
OBJECT-TYPE
The number of short incoming frames detected by L2
1.3.6.1.4.1.711.2.1.11.1.2.1.1.9Counterread-onlymandatory
lsTrunkCpuWorkloadTable
OBJECT-TYPE
Trunk Card Workload Statistics Counter Table
1.3.6.1.4.1.711.2.1.11.1.2.2not-accessiblemandatory
lsTrunkCpuWorkloadEntry
OBJECT-TYPE
An entry in the Trunk Cpu Workload Table
1.3.6.1.4.1.711.2.1.11.1.2.2.1not-accessiblemandatory
lsTrunkWorkloadCardIndex
OBJECT-TYPE
Unique Trunk card Index consisting of card's slot number
1.3.6.1.4.1.711.2.1.11.1.2.2.1.1INTEGERread-onlymandatory
lsTrunkWorkloadTypeIndex
OBJECT-TYPE
Trunk CPU Workload Counter Variable: 1 - average workload
1.3.6.1.4.1.711.2.1.11.1.2.2.1.2INTEGER {average(1)}read-onlymandatory
lsTrunkWorkloadEvents
OBJECT-TYPE
Trunk Cpu Workload Counter for the specified Workload Variable
1.3.6.1.4.1.711.2.1.11.1.2.2.1.3Counterread-onlymandatory
lsLcStatistics
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.11.1.3
lcStatTable
OBJECT-TYPE
Table of objects, such as FSU and TSU objects, which exist across for either trunk or edge cards, indexed by the line card alone. Some of these objects may require ASIC HW.
1.3.6.1.4.1.711.2.1.11.1.3.1not-accessiblemandatory
lcStatEntry
OBJECT-TYPE
An entry in the LC common FSU Stat table.
1.3.6.1.4.1.711.2.1.11.1.3.1.1not-accessiblemandatory
lcStatCardIndex
OBJECT-TYPE
Unique Line Card index
1.3.6.1.4.1.711.2.1.11.1.3.1.1.1INTEGERread-onlymandatory
tsuFreeCells
OBJECT-TYPE
The total number of free cells available on the Tsu
1.3.6.1.4.1.711.2.1.11.1.3.1.1.2Gaugeread-onlymandatory
fsuSharedFreeCells
OBJECT-TYPE
Number of Cells on the shared free-list in the FSU.
1.3.6.1.4.1.711.2.1.11.1.3.1.1.3INTEGERread-onlymandatory
tsuCellDropLastVci
OBJECT-TYPE
The last VCI index associated with a message dropped by the TSU due to buffer shortage. This index implicitly determines the port and connection.
1.3.6.1.4.1.711.2.1.11.1.3.1.1.4INTEGERread-onlymandatory
switchCellDgRejectEvents
OBJECT-TYPE
The number of switch rejects of datagram cells. These are not errors, but this does provide a measure of switch contention. May only be available on ASIC HW Line Cards.
1.3.6.1.4.1.711.2.1.11.1.3.1.1.5Counterread-onlymandatory
switchCellSchedRejectEvents
OBJECT-TYPE
The number of switch rejects of datagram cells. These are errors, since appropriate scheduling should not allow these. May only be available on ASIC HW Line Cards.
1.3.6.1.4.1.711.2.1.11.1.3.1.1.6Counterread-onlymandatory
tsuErrFutQCellDrops
OBJECT-TYPE
The number of cells dropped due to FutureQ Overruns
1.3.6.1.4.1.711.2.1.11.1.3.1.1.7Counterread-onlymandatory
tsuErrFutQMsgDropLastVci
OBJECT-TYPE
The last Vci index associated with a cell dropped due to FutureQ overrun.
1.3.6.1.4.1.711.2.1.11.1.3.1.1.8INTEGERread-onlymandatory
fsuHdrLrcErrs
OBJECT-TYPE
The total number of LRC errors detected by the FSU
1.3.6.1.4.1.711.2.1.11.1.3.1.1.9Counterread-onlymandatory
fsuPayloadLrcErrs
OBJECT-TYPE
The total number of LRC errors detected by the FSU
1.3.6.1.4.1.711.2.1.11.1.3.1.1.10Counterread-onlymandatory
lcPortStatTable
OBJECT-TYPE
Table of Line Card (Edge and Trunk) Statistics by port. There are a number of TSU and FSU statistics in common to edges and trunks. Some of the objects in this table may be limited in use to ASIC HW.
1.3.6.1.4.1.711.2.1.11.1.3.2not-accessiblemandatory
lcPortStatEntry
OBJECT-TYPE
An entry in the Line Card Stat Table, indexed by port.
1.3.6.1.4.1.711.2.1.11.1.3.2.1not-accessiblemandatory
lcStatPortIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.11.1.3.2.1.1INTEGERread-onlymandatory
fsuPortFreeCells
OBJECT-TYPE
Number of Cells on per-port FSU free lists.
1.3.6.1.4.1.711.2.1.11.1.3.2.1.2Gaugeread-onlymandatory
fsuCellDropLastCellHdr
OBJECT-TYPE
The last Cell Header associated with a FSU cell drop due to buffer shortage. Provides a clue as to which VCIs are being dropped. Since this is a full 32-bit header, the CLP bit state is available. The XCLP and Queue can be inferred from indirect lookup based on the header, if desired.
1.3.6.1.4.1.711.2.1.11.1.3.2.1.3INTEGERread-onlymandatory
tsuPortErrL1UnconfigVcis
OBJECT-TYPE
The number of cells received by the TSU for which the the VCI was not configured within the Level 1 table. Cells for unconfigured VCIs are dropped.
1.3.6.1.4.1.711.2.1.11.1.3.2.1.4Counterread-onlymandatory
tsuPortErrL2UnconfigVcis
OBJECT-TYPE
The number of cells received by the TSU for which the the VCI was not configured within the Level 2 table. Cells for unconfigured VCIs are dropped.
1.3.6.1.4.1.711.2.1.11.1.3.2.1.5Counterread-onlymandatory
tsuPortErrL1UnconfigLastVci
OBJECT-TYPE
The last 4-byte cell header associated with a Level 1 unconfigured VCI.
1.3.6.1.4.1.711.2.1.11.1.3.2.1.6INTEGERread-onlymandatory
tsuPortErrL2UnconfigLastVci
OBJECT-TYPE
The last 4-byte cell header associated with a Level 2 unconfigured VCI.
1.3.6.1.4.1.711.2.1.11.1.3.2.1.7INTEGERread-onlymandatory
tsuPortErrNonZeroGfc
OBJECT-TYPE
For a UNI, the number of cells received with a non-zero GFC byte. No action taken aside from counting.
1.3.6.1.4.1.711.2.1.11.1.3.2.1.8Counterread-onlymandatory
fsuPortXmtCellsTable
OBJECT-TYPE
Table of cells transmited by FSU to either a line-card chip or TLU, indexed by port and a drop priority subindex which represents the CLP and XCLP status of the cells. The priority index is tentatively defined as 2*CLP + XCLP + 1. Does not count cells dropped due to FSU buffer shortages or header LRC errors. Availability may depend on HW.
1.3.6.1.4.1.711.2.1.11.1.3.3not-accessiblemandatory
fsuPortXmtCellsEntry
OBJECT-TYPE
An entry in the LC common FSU Port Xmt Cells Table.
1.3.6.1.4.1.711.2.1.11.1.3.3.1not-accessiblemandatory
fsuXmtCellsPortIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.11.1.3.3.1.1INTEGERread-onlymandatory
fsuXmtCellsPriorityIndex
OBJECT-TYPE
Index specifying the CLP and XCLP priority substream for the port. Index defined as 2*CLP + XCLP + 1.
1.3.6.1.4.1.711.2.1.11.1.3.3.1.2INTEGER (1..4)read-onlymandatory
fsuXmtCellEvents
OBJECT-TYPE
Number of cells forwarded by the FSU towards the port indicated by the PortIndex, by the specified priority.
1.3.6.1.4.1.711.2.1.11.1.3.3.1.3Counterread-onlymandatory
fsuQueueCellLengthTable
OBJECT-TYPE
Table of current queue lengths by port and subqueue as measured in cells.
1.3.6.1.4.1.711.2.1.11.1.3.4not-accessiblemandatory
fsuQueueCellLenEntry
OBJECT-TYPE
An entry in the FSU queue length table
1.3.6.1.4.1.711.2.1.11.1.3.4.1not-accessiblemandatory
fsuQueueCellLenPortIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.11.1.3.4.1.1INTEGERread-onlymandatory
fsuQueueCellLenSubQIndex
OBJECT-TYPE
Index specifying the subqueue for the port, where a lower queue number has a lower fsu priority.
1.3.6.1.4.1.711.2.1.11.1.3.4.1.2INTEGER (1..5)read-onlymandatory
fsuQueueCellLength
OBJECT-TYPE
Length of the specified queue in cell units. For ASIC Edge versions, this will include cells on the reassembly Queue for a port. For non-ASIC Edge versions, does not include reassembly Queue. Non-ASIC versions provide an estimate due to slow-side scanner logic, while ASIC versions provide direct counts.
1.3.6.1.4.1.711.2.1.11.1.3.4.1.3Gaugeread-onlymandatory
fsuDropEventTable
OBJECT-TYPE
Table of drop events by FSU due to buffer shortage, by Port and drop watermark. This table may be limited in use to ASIC HW. For ASIC these are cell drops. For non-ASIC, might be messages instead of cells.
1.3.6.1.4.1.711.2.1.11.1.3.5not-accessiblemandatory
fsuDropEventEntry
OBJECT-TYPE
An entry in the FSU Port/Watermark drop event table
1.3.6.1.4.1.711.2.1.11.1.3.5.1not-accessiblemandatory
fsuDropEventPortIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.11.1.3.5.1.1INTEGERread-onlymandatory
fsuDropEventWatermarkIndex
OBJECT-TYPE
Watermark associated with the drop count. The watermark selected is a function of the Fsu Priority, CLP and XCLP within port. We tentively define it to be (FSU-Priority)*4 + 2*CLP + XCLP+1. CLP and XCLP are 0/1 valued. At this time, there are eight Fsu priorities (treated as 0-7 in increasing priority), however these components cannot vary independently as currently used. Therefore, some entries will either not exist or will have a non-varying (default) count of zero.
1.3.6.1.4.1.711.2.1.11.1.3.5.1.2INTEGERread-onlymandatory
fsuDropEvents
OBJECT-TYPE
Count of the number drop events (cells or messages) dropped by the FSU due to low buffers, for the specified port and drop watermark.
1.3.6.1.4.1.711.2.1.11.1.3.5.1.3Counterread-onlymandatory
lsFsuFastDropTable
OBJECT-TYPE
Table of cells dropped by FSU due to buffer shortage, by drop watermark, for cards using the fast-side drop mechanism. These statistics are not available for other cards.
1.3.6.1.4.1.711.2.1.11.1.3.6not-accessiblemandatory
lsFsuFastDropEntry
OBJECT-TYPE
An entry in the FSU fast-side per watermark drop table
1.3.6.1.4.1.711.2.1.11.1.3.6.1not-accessiblemandatory
lsFsuFastDropWatermarkIndex
OBJECT-TYPE
Watermark used for dropping with the fast-drop mechanism.
1.3.6.1.4.1.711.2.1.11.1.3.6.1.1INTEGER {clp1(1), clp0HiPriority(2), clp0HiOther(3)}read-onlymandatory
lsFsuFastCellDropEvents
OBJECT-TYPE
Count of the number cells dropped by FSU due to low buffers, for the specified watermark, using the fast-drop mechanism. These should be rare if the slow-side mechanism is functioning properly.
1.3.6.1.4.1.711.2.1.11.1.3.6.1.2Counterread-onlymandatory
tsuDropEventTable
OBJECT-TYPE
Table of drop events by TSU due to buffer shortage, by Port and drop watermark. A drop event corresponds to a cell drop for ASIC cards. It may correspond to frame drops` on other cards.
1.3.6.1.4.1.711.2.1.11.1.3.7not-accessiblemandatory
tsuDropEventEntry
OBJECT-TYPE
An entry in the Edge Port/Watermark TSU drop events table
1.3.6.1.4.1.711.2.1.11.1.3.7.1not-accessiblemandatory
tsuDropEventPortIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.11.1.3.7.1.1INTEGERread-onlymandatory
tsuDropEventWatermarkIndex
OBJECT-TYPE
Watermark associated with the drop count.
1.3.6.1.4.1.711.2.1.11.1.3.7.1.2INTEGER {user(1), control(2), scheduled(3)}read-onlymandatory
tsuDropEvents
OBJECT-TYPE
TSU drop events due to low buffers, for the specified port and drop watermark. For ASIC cards these are cell drops. For other cards the unit may be messages, depending on the card. These drops should be rare. They could be a byproduct of incorrect scheduled service setup.
1.3.6.1.4.1.711.2.1.11.1.3.7.1.3Counterread-onlymandatory
lsUtStatistics
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.11.1.4
lsLcFsuIntervalTable
OBJECT-TYPE
Table of sampled FSU queue depths and drop information, by outbound port (trunk and edge) where sampling occurs for queue depth is sampled once per second and data is aggregated into one minute buckets defined by the lsLcIntervalNumber.
1.3.6.1.4.1.711.2.1.11.1.4.1not-accessiblemandatory
lsLcFsuIntervalEntry
OBJECT-TYPE
An entry in the LC FSU Interval table
1.3.6.1.4.1.711.2.1.11.1.4.1.1not-accessiblemandatory
lsLcIntervalPortIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above. The port may be logical (e.g. terminated by a processor).
1.3.6.1.4.1.711.2.1.11.1.4.1.1.1INTEGERread-onlymandatory
lsLcIntervalNumber
OBJECT-TYPE
A number between 1 and 60, where 1 is the most recently completed 1 minute interval and 60 is the least recently completed one minute interval (assuming that all 60 intervals are valid). Currently only interval of 1 is supported
1.3.6.1.4.1.711.2.1.11.1.4.1.1.2INTEGER (1..60)read-onlymandatory
lsLcIntervalPSDepth
OBJECT-TYPE
Peak sampled queue depth for this outbound port, in cells, where queue depth is sampled once per second.
1.3.6.1.4.1.711.2.1.11.1.4.1.1.3INTEGERread-onlymandatory
lsLcIntervalASDepth
OBJECT-TYPE
Average sampled queue depth for this outbound port, in cells, where queue depth is sampled once per second.
1.3.6.1.4.1.711.2.1.11.1.4.1.1.4INTEGERread-onlymandatory
lsLcIntervalDropEvents
OBJECT-TYPE
The Number of cell drop events encountered for this port during the specified interval. This provides the average cell loss ratio over the interval.
1.3.6.1.4.1.711.2.1.11.1.4.1.1.5INTEGERread-onlymandatory
lsLcIntervalAvgCells
OBJECT-TYPE
The Number of cells transmitted for this port during the specified interval. This provides average utilization over the interval.
1.3.6.1.4.1.711.2.1.11.1.4.1.1.6INTEGERread-onlymandatory
lsLcIntervalPeakCells
OBJECT-TYPE
The Peak Number of cells transmitted for this port during any one second measurement period within the specified interval. This provides peak one-second utilization information.
1.3.6.1.4.1.711.2.1.11.1.4.1.1.7INTEGERread-onlymandatory
lsLcIntervalMinPermits
OBJECT-TYPE
The Minimum Permit value as sampled once per second during the specified interval.
1.3.6.1.4.1.711.2.1.11.1.4.1.1.8INTEGERread-onlymandatory
lsLcIntervalAvgPermits
OBJECT-TYPE
The Average Permit value as sampled once per second during the specified interval.
1.3.6.1.4.1.711.2.1.11.1.4.1.1.9INTEGERread-onlymandatory
lsLcIntervalMaxPermits
OBJECT-TYPE
The Maximum Permit value as sampled once per second during the specified interval.
1.3.6.1.4.1.711.2.1.11.1.4.1.1.10INTEGERread-onlymandatory
lsLcIntervalDecrPermits
OBJECT-TYPE
The Number of Permit decrease updates submitted during the current interval
1.3.6.1.4.1.711.2.1.11.1.4.1.1.11INTEGERread-onlymandatory
lsLcIntervalIncrPermits
OBJECT-TYPE
The Number of Permit increase updates submitted during the current interval
1.3.6.1.4.1.711.2.1.11.1.4.1.1.12INTEGERread-onlymandatory
lsLcIntervalMinBwAlloc
OBJECT-TYPE
The minimum BW allocation assessed during the current interval.
1.3.6.1.4.1.711.2.1.11.1.4.1.1.13INTEGERread-onlymandatory
lsLcIntervalAvgBwAlloc
OBJECT-TYPE
The minimum BW allocation assessed during the current interval.
1.3.6.1.4.1.711.2.1.11.1.4.1.1.14INTEGERread-onlymandatory
lsLcIntervalMaxBwAlloc
OBJECT-TYPE
The maximum BW allocation assessed during the current interval.
1.3.6.1.4.1.711.2.1.11.1.4.1.1.15INTEGERread-onlymandatory
lsNpStatistics
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.11.1.5
lsNpCpuWorkloadTable
OBJECT-TYPE
Network processor CPU specific workload statistics
1.3.6.1.4.1.711.2.1.11.1.5.1not-accessiblemandatory
lsNpCpuWorkloadEntry
OBJECT-TYPE
An entry in the Network Processor Statistics table.
1.3.6.1.4.1.711.2.1.11.1.5.1.1not-accessiblemandatory
lsNpCpuWorkloadIndex
OBJECT-TYPE
Np CPU Workload variable identifier
1.3.6.1.4.1.711.2.1.11.1.5.1.1.1INTEGERread-onlymandatory
lsNpCpuWorkloadEvents
OBJECT-TYPE
NP workload event count
1.3.6.1.4.1.711.2.1.11.1.5.1.1.2Counterread-onlymandatory
lsCellStatistics
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.11.1.6
lsCellVciStatTable
OBJECT-TYPE
Cell Port/VCI specific statistics subset information
1.3.6.1.4.1.711.2.1.11.1.6.1not-accessiblemandatory
lsCellVciStatEntry
OBJECT-TYPE
An entry in the cell Port/Vci Statistics Table.
1.3.6.1.4.1.711.2.1.11.1.6.1.1not-accessiblemandatory
cellVciStatPortIndex
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.11.1.6.1.1.1INTEGERread-onlymandatory
cellVciStatVciIndex
OBJECT-TYPE
Unique Vci identifier for indicated VC
1.3.6.1.4.1.711.2.1.11.1.6.1.1.2INTEGERread-onlymandatory
cellVciToSwCLP0Cells
OBJECT-TYPE
Number of Cells forwarded to TSU with CLP=0
1.3.6.1.4.1.711.2.1.11.1.6.1.1.3Counterread-onlymandatory
cellVciToSwCLP01Cells
OBJECT-TYPE
Number of Cells forwarded to TSU with CLP=1, which arrived at port as CLP=0.
1.3.6.1.4.1.711.2.1.11.1.6.1.1.4Counterread-onlymandatory
cellVciToSwCLP1Cells
OBJECT-TYPE
Number of Cells forwarded to TSU with CLP=1
1.3.6.1.4.1.711.2.1.11.1.6.1.1.5Counterread-onlymandatory
cellVciToSwDiscardCells
OBJECT-TYPE
Number of to-switch Cells discarded due to excessive traffic according to the Usage Parameter Descriptor for this Vci
1.3.6.1.4.1.711.2.1.11.1.6.1.1.6Counterread-onlymandatory
lsIR
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.12
irRoutingGroup
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.12.1
irRoutingPathsGenerated
OBJECT-TYPE
The number of path generation operations performed since initialization.
1.3.6.1.4.1.711.2.1.12.1.1Counterread-onlymandatory
irRoutingPathGenSuccess
OBJECT-TYPE
The number of path generation operations successfully performed since initialization.
1.3.6.1.4.1.711.2.1.12.1.2Counterread-onlymandatory
irRoutingPathGenFailedNoResources
OBJECT-TYPE
The number of path generation operations which have failed due to lack of network resources.
1.3.6.1.4.1.711.2.1.12.1.3Counterread-onlymandatory
irRoutingPathGenFailedUnknown
OBJECT-TYPE
The number of path generation operations which have failed because a specified port or chassis was unknown.
1.3.6.1.4.1.711.2.1.12.1.4Counterread-onlymandatory
irRoutingPathGenFailedOther
OBJECT-TYPE
The number of path generation operations which have failed for reasons other than unknown chassis/port or lack of network resources.
1.3.6.1.4.1.711.2.1.12.1.5Counterread-onlymandatory
irRoutingAveragePathLength
OBJECT-TYPE
The average length (in ports) of all paths generated since initialization.
1.3.6.1.4.1.711.2.1.12.1.6Counterread-onlymandatory
lsStatistics
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.13
tcsInfo
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.14
tcsTable
OBJECT-TYPE
TCS Slave specific information
1.3.6.1.4.1.711.2.1.14.1not-accessiblemandatory
tcsEntry
OBJECT-TYPE
An entry in the tcs table ordered by slot. (1-n)
1.3.6.1.4.1.711.2.1.14.1.1not-accessiblemandatory
tcsIndex
OBJECT-TYPE
Unique Index consisting of slot number.
1.3.6.1.4.1.711.2.1.14.1.1.1INTEGERread-onlymandatory
tcsTemp1
OBJECT-TYPE
Temperature 1 detected by TCS.
1.3.6.1.4.1.711.2.1.14.1.1.2INTEGERread-onlymandatory
tcsTemp2
OBJECT-TYPE
Temperature 2 detected by TCS.
1.3.6.1.4.1.711.2.1.14.1.1.3INTEGERread-onlymandatory
tcsTcsVoltage
OBJECT-TYPE
Voltage detected by TCS.
1.3.6.1.4.1.711.2.1.14.1.1.4INTEGERread-onlymandatory
tcsVccVoltage
OBJECT-TYPE
VCC Voltage detected by TCS.
1.3.6.1.4.1.711.2.1.14.1.1.5INTEGERread-onlymandatory
tcsScsiVoltage
OBJECT-TYPE
SCSI Voltage (or Bulk for switches) detected by TCS.
1.3.6.1.4.1.711.2.1.14.1.1.7INTEGERread-onlymandatory
tcsPostResult
OBJECT-TYPE
POST result of card.
1.3.6.1.4.1.711.2.1.14.1.1.8OCTET STRING (SIZE(6))read-onlymandatory
tcsCardType
OBJECT-TYPE
Card type.
1.3.6.1.4.1.711.2.1.14.1.1.9INTEGER {empty(1), error(2), unknown(3), switch(4), np(5), lsEdge(6), lsTrunk(7), msTrunk(8), msEdge(10), plc12fac1(11), plc18eac1(12), plc1Lstoken(13), plc18sac1Edge(14), plc18sac1Trunk(15), clc1Gen(30), clc12oc3ac1Edge(31), clc12oc3ac1Trunk(32), clc18t3ac1Edge(33), clc18t3ac1Trunk(34), clc12taxiac1Edge(35), clc12taxiac1Trunk(36), clc18t1e1cbrac1(37), switch2(70)}read-onlymandatory
tcsPaddleTemp1
OBJECT-TYPE
Paddle card temperature 1 detected by TCS.
1.3.6.1.4.1.711.2.1.14.1.1.10INTEGERread-onlymandatory
tcsPaddleTemp2
OBJECT-TYPE
Paddle card temperature 2 detected by TCS.
1.3.6.1.4.1.711.2.1.14.1.1.11INTEGERread-onlymandatory
tcsPaddleWarnTemp1
OBJECT-TYPE
Paddle card warning temperature 1 maintained by TCS.
1.3.6.1.4.1.711.2.1.14.1.1.12INTEGERread-onlymandatory
tcsPaddleWarnTemp2
OBJECT-TYPE
Paddle card warning temperature 2 maintained by TCS.
1.3.6.1.4.1.711.2.1.14.1.1.13INTEGERread-onlymandatory
tcsPaddleShutdownTemp1
OBJECT-TYPE
Warning temperature 1 at which the paddle card will shut down.
1.3.6.1.4.1.711.2.1.14.1.1.14INTEGERread-onlymandatory
tcsPaddleShutdownTemp2
OBJECT-TYPE
Warning temperature 2 at which the paddle card will shut down.
1.3.6.1.4.1.711.2.1.14.1.1.15INTEGERread-onlymandatory
tcsWarnTemp1
OBJECT-TYPE
Warning temperature 1 maintained by TCS.
1.3.6.1.4.1.711.2.1.14.1.1.16INTEGERread-onlymandatory
tcsWarnTemp2
OBJECT-TYPE
Warning temperature 2 maintained by TCS.
1.3.6.1.4.1.711.2.1.14.1.1.17INTEGERread-onlymandatory
tcsShutdownTemp1
OBJECT-TYPE
Warning temperature 2 at which the card will shut down.
1.3.6.1.4.1.711.2.1.14.1.1.18INTEGERread-onlymandatory
tcsShutdownTemp2
OBJECT-TYPE
Warning temperature 2 at which the card will shut down.
1.3.6.1.4.1.711.2.1.14.1.1.19INTEGERread-onlymandatory
tcsFaultLight
OBJECT-TYPE
The state of the fault light.
1.3.6.1.4.1.711.2.1.14.1.1.20INTEGER {on(1), off(2)}read-onlymandatory
tcsReadyLight
OBJECT-TYPE
The state of the ready light
1.3.6.1.4.1.711.2.1.14.1.1.21INTEGER {on(1), off(2)}read-onlymandatory
tcsSwitchConnectivityMask
OBJECT-TYPE
Bitmask of cards with which this function card communicates via the switch. Bit 0 is the least-significant bit. Bit 1 represents slot 1, bit 2 represents slot 2 and so on.
1.3.6.1.4.1.711.2.1.14.1.1.22INTEGERread-onlymandatory
tcsPrimarySwitch
OBJECT-TYPE
Primary Switch. When 'read' provides the current primary switch. When 'written' attempts to make the written value the new switch.
1.3.6.1.4.1.711.2.1.14.2INTEGER {switchA(1), switchB(2)}read-writemandatory
tcsPowerSupplyA
OBJECT-TYPE
Status of power supply A.
1.3.6.1.4.1.711.2.1.14.3INTEGER {empty(1), failed(2), good(3)}read-onlymandatory
tcsPowerSupplyB
OBJECT-TYPE
Status of power supply B.
1.3.6.1.4.1.711.2.1.14.4INTEGER {empty(1), failed(2), good(3)}read-onlymandatory
tcsPowerSupplyTypeA
OBJECT-TYPE
Type of power supply A.
1.3.6.1.4.1.711.2.1.14.5INTEGER {empty(1), dcPowerTray(2), toddPS(3), unknown(4)}read-onlymandatory
tcsPowerSupplyTypeB
OBJECT-TYPE
Type of power supply A.
1.3.6.1.4.1.711.2.1.14.6INTEGER {empty(1), dcPowerTray(2), toddPS(3), unknown(4)}read-onlymandatory
tcsSwitchFaultMaskA
OBJECT-TYPE
Bitmask of slots reporting unhealthy clocks. If the corresponding bit is set, switch card A's clock is viewed as unhealthy by the function card in that slot. In addition, it indicates whether or not the entire switch card has been marked as usable or unusable. Bit 1 represents clock health for slot 1, bit 2 represents slot 2 and so on. Bit 0 is the least-significant bit. Bit 0 represents the dont-use bit for switch A. If bit 0 is set, it indicates that TCS has marked switch A as dont-use.
1.3.6.1.4.1.711.2.1.14.7INTEGERread-onlymandatory
tcsSwitchFaultMaskB
OBJECT-TYPE
Bitmask of slots reporting unhealthy clocks. If the corresponding bit is set, switch card B's clock is viewed as unhealthy by the function card in that slot. In addition, it indicates whether or not the entire switch card has been marked as usable or unusable. Bit 1 represents clock health for slot 1, bit 2 represents slot 2 and so on. Bit 0 is the least-significant bit. Bit 0 represents the dont-use bit for switch B. If bit 0 is set, it indicates that TCS has marked switch B as dont-use.
1.3.6.1.4.1.711.2.1.14.8INTEGERread-onlymandatory
tcsSwitchCutoverSupport
OBJECT-TYPE
willDoLossLess indicates that there are two SC2's that are in synch. wontDoLossLess indicates that there are two SC2's that are NOT in sync. cantDoLossLess indicates any other situation (1-SC1/SC2, 2-SC1's).
1.3.6.1.4.1.711.2.1.14.9INTEGER {willDoLossLess(1), wontDoLossLess(2), cantDoLossLess(3)}read-onlymandatory
tcsFCPrimarySwitchA
OBJECT-TYPE
The bit corresponding to that slot is a 1 if the card believes that Switch A is the primary switch and 0 otherwise. Bit 0 is the least-significant bit. Bit 1 represents slot 1, bit 2 represents slot 2 and so on.
1.3.6.1.4.1.711.2.1.14.10INTEGERread-onlymandatory
tcsFCPrimarySwitchB
OBJECT-TYPE
The bit corresponding to that slot is a 1 if the card believes that Switch B is the primary switch and 0 otherwise. Bit 0 is the least-significant bit. Bit 1 represents slot 1, bit 2 represents slot 2 and so on.
1.3.6.1.4.1.711.2.1.14.11INTEGERread-onlymandatory
lsGID
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.15
gidGeneralGroup
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.15.1
gidSoftwareVersionNumber
OBJECT-TYPE
The global information distribution (GID) process software revision number
1.3.6.1.4.1.711.2.1.15.1.1DisplayStringread-onlymandatory
gidProcessID
OBJECT-TYPE
The GID process ID.
1.3.6.1.4.1.711.2.1.15.1.2INTEGERread-onlymandatory
gidUpTime
OBJECT-TYPE
The number of seconds the GID process has been running.
1.3.6.1.4.1.711.2.1.15.1.3INTEGERread-onlymandatory
gidMemoryUse
OBJECT-TYPE
The total amount of memory (in bytes) currently allocated by GID for all purposes.
1.3.6.1.4.1.711.2.1.15.1.4Counterread-onlymandatory
gidTimersProcessed
OBJECT-TYPE
The number of timers processed by the GID process since initialization.
1.3.6.1.4.1.711.2.1.15.1.5Counterread-onlymandatory
gidMallocFailures
OBJECT-TYPE
The number of times GID has failed to dynamically allocate memory since initialization.
1.3.6.1.4.1.711.2.1.15.1.6Counterread-onlymandatory
gidDebugFlag
OBJECT-TYPE
Bit mask for debug statements to AppLog. This is being used for debug purposes. It is not advised that the user change this. Future releases may move this to a debug subtree.
1.3.6.1.4.1.711.2.1.15.1.7INTEGERread-writemandatory
gidDebugLevel
OBJECT-TYPE
The gidDebugLevel determines the amount of detail that the debug flags will cause to dump to the apps.log, where 0 means no detail and 3 is the maximum value Future releases may move this to a debug subtree.
1.3.6.1.4.1.711.2.1.15.1.8INTEGERread-writemandatory
gidAcceptedBcastRateIn
OBJECT-TYPE
The LAN inbound broadcast traffic average inter-frame time specified in microseconds. The default rate is 20,000 microseconds. Defines the acceptable average inbound bcast rate. Future releases may move this to another subtree.
1.3.6.1.4.1.711.2.1.15.1.9INTEGERread-writemandatory
gidNbrGroup
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.15.2
gidNbrCount
OBJECT-TYPE
The number of neighbor NPs known to the GID process.
1.3.6.1.4.1.711.2.1.15.2.1Counterread-onlymandatory
gidNbrTable
OBJECT-TYPE
A table containing information about each GID neighbor.
1.3.6.1.4.1.711.2.1.15.2.2not-accessiblemandatory
gidNbrEntry
OBJECT-TYPE
The information regarding a single GID neighbor.
1.3.6.1.4.1.711.2.1.15.2.2.1not-accessiblemandatory
gidNbrEIA
OBJECT-TYPE
The internal address of the neighbor NP.
1.3.6.1.4.1.711.2.1.15.2.2.1.1INTEGERread-onlymandatory
gidNbrVCI
OBJECT-TYPE
The VCI of the reliable channel to the neighbor.
1.3.6.1.4.1.711.2.1.15.2.2.1.2INTEGERread-onlymandatory
gidNbrState
OBJECT-TYPE
The neighbor's synchronization protocol state.
1.3.6.1.4.1.711.2.1.15.2.2.1.3INTEGER {unknown(1), existent(2), exstart(3), exchange(4), loading(5), full(6)}read-onlymandatory
gidNbrSyncEvents
OBJECT-TYPE
The number of synchronization protocol events associated with this neighbor that have occurred since initialization.
1.3.6.1.4.1.711.2.1.15.2.2.1.4Counterread-onlymandatory
gidNbrDBReqListLength
OBJECT-TYPE
The number of database requests queued to the neighbor.
1.3.6.1.4.1.711.2.1.15.2.2.1.5Counterread-onlymandatory
gidNbrDBSumListLength
OBJECT-TYPE
The number of database summary list entries queued for transmission to the neighbor.
1.3.6.1.4.1.711.2.1.15.2.2.1.6Counterread-onlymandatory
gidNbrHellosRx
OBJECT-TYPE
The number of Hello packets received from the neighbor.
1.3.6.1.4.1.711.2.1.15.2.2.1.7Counterread-onlymandatory
gidNbrLinkAnnouncementsRx
OBJECT-TYPE
The number of link state announcements received from the neighbor.
1.3.6.1.4.1.711.2.1.15.2.2.1.8Counterread-onlymandatory
gidNbrNewLinkAnnouncementsRx
OBJECT-TYPE
The number of link state announcements received from the neighbor and accepted as new.
1.3.6.1.4.1.711.2.1.15.2.2.1.9Counterread-onlymandatory
gidNbrIPAnnouncementsRx
OBJECT-TYPE
The number of internal IP address translation announcements received from the neighbor.
1.3.6.1.4.1.711.2.1.15.2.2.1.10Counterread-onlymandatory
gidNbrNewIPAnnouncementsRx
OBJECT-TYPE
The number of internal IP address translation announcements received from the neighbor and accepted as new.
1.3.6.1.4.1.711.2.1.15.2.2.1.11Counterread-onlymandatory
gidNbrGenericAnnouncementsRx
OBJECT-TYPE
The number of generic global information announcements received from the neighbor.
1.3.6.1.4.1.711.2.1.15.2.2.1.12Counterread-onlymandatory
gidNbrNewGenericAnnouncementsRx
OBJECT-TYPE
The number of generic global information announcements received from the neighbor and accepted as new.
1.3.6.1.4.1.711.2.1.15.2.2.1.13Counterread-onlymandatory
gidClientGroup
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.15.3
gidClientCount
OBJECT-TYPE
The number of registered GID client processes.
1.3.6.1.4.1.711.2.1.15.3.1Counterread-onlymandatory
gidClientTable
OBJECT-TYPE
A table containing information about each GID client process.
1.3.6.1.4.1.711.2.1.15.3.2not-accessiblemandatory
gidClientEntry
OBJECT-TYPE
The information regarding a single GID client process.
1.3.6.1.4.1.711.2.1.15.3.2.1not-accessiblemandatory
gidClientID
OBJECT-TYPE
The GID client process identifier.
1.3.6.1.4.1.711.2.1.15.3.2.1.1INTEGERread-onlymandatory
gidClientEIA
OBJECT-TYPE
The internal card address associated with the GID client process. Edge and trunk card control processes are associated with a unique card address. The NP card control process and the Congestion Avoidance information distribution process share the internal card address of the local NP.
1.3.6.1.4.1.711.2.1.15.3.2.1.2INTEGERread-onlymandatory
gidClientAnnouncementsRx
OBJECT-TYPE
The total number of global information announcements received from this GID client process since initialization.
1.3.6.1.4.1.711.2.1.15.3.2.1.3Counterread-onlymandatory
gidClientLinkAnnouncementsRx
OBJECT-TYPE
The number of link state information announcements received from this GID client process since initialization.
1.3.6.1.4.1.711.2.1.15.3.2.1.4Counterread-onlymandatory
gidClientIPAnnouncementsRx
OBJECT-TYPE
The number of internal IP address translation announcements received from this GID client process since initialization.
1.3.6.1.4.1.711.2.1.15.3.2.1.5Counterread-onlymandatory
gidClientGenericAnnouncementsRx
OBJECT-TYPE
The number of generic global information announcements received from this GID client process since initialization.
1.3.6.1.4.1.711.2.1.15.3.2.1.6Counterread-onlymandatory
gidClientEventsTx
OBJECT-TYPE
The number of global information-related events sent by the GID process to the GID client process since initialization.
1.3.6.1.4.1.711.2.1.15.3.2.1.7Counterread-onlymandatory
gidClientPathsGenerated
OBJECT-TYPE
The number of path generation requests made by the GID client process since initialization.
1.3.6.1.4.1.711.2.1.15.3.2.1.8Counterread-onlymandatory
gidIOGroup
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.15.4
gidIONbrMsgBuffersFree
OBJECT-TYPE
The number of neighbor message buffers available on the neighbor message buffer free list.
1.3.6.1.4.1.711.2.1.15.4.1Counterread-onlymandatory
gidIONbrMsgBuffersActive
OBJECT-TYPE
The number of neighbor message buffers currently active, either in transmission or queued for output.
1.3.6.1.4.1.711.2.1.15.4.2Counterread-onlymandatory
gidIOClientMsgBuffersFree
OBJECT-TYPE
The number of client message buffers available on the client message buffer free list.
1.3.6.1.4.1.711.2.1.15.4.3Counterread-onlymandatory
gidIOClientMsgBuffersActive
OBJECT-TYPE
The number of client message buffers currently active, either in transmission or queued for output.
1.3.6.1.4.1.711.2.1.15.4.4Counterread-onlymandatory
gidSyncGroup
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.15.6
gidSyncNbrsExistent
OBJECT-TYPE
The number of neighbors in the Existent synchronization protocol state.
1.3.6.1.4.1.711.2.1.15.6.1Counterread-onlymandatory
gidSyncNbrsExStart
OBJECT-TYPE
The number of neighbors in the Exchange Start synchronization protocol state.
1.3.6.1.4.1.711.2.1.15.6.2Counterread-onlymandatory
gidSyncNbrsExchange
OBJECT-TYPE
The number of neighbors in the Exchange synchronization protocol state.
1.3.6.1.4.1.711.2.1.15.6.3Counterread-onlymandatory
gidSyncNbrsLoading
OBJECT-TYPE
The number of neighbors in the Loading synchronization protocol state.
1.3.6.1.4.1.711.2.1.15.6.4Counterread-onlymandatory
gidSyncNbrsFull
OBJECT-TYPE
The number of neighbors in the Full synchronization protocol state.
1.3.6.1.4.1.711.2.1.15.6.5Counterread-onlymandatory
gidLinkGroup
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.15.7
gidLinkDatabaseSize
OBJECT-TYPE
The current size of the link state database, in bytes.
1.3.6.1.4.1.711.2.1.15.7.1INTEGERread-onlymandatory
gidLineCardTable
OBJECT-TYPE
A table containing information about each line card known to GID.
1.3.6.1.4.1.711.2.1.15.7.2not-accessiblemandatory
gidLineCardEntry
OBJECT-TYPE
The information regarding a single line card.
1.3.6.1.4.1.711.2.1.15.7.2.1not-accessiblemandatory
gidLineCardChassis
OBJECT-TYPE
The internal chassis ID of the chassis which contains the line card described by the link state entry.
1.3.6.1.4.1.711.2.1.15.7.2.1.1INTEGERread-onlymandatory
gidLineCardSlot
OBJECT-TYPE
The slot in the chassis which contains the line card described by the link state entry.
1.3.6.1.4.1.711.2.1.15.7.2.1.2INTEGERread-onlymandatory
gidLineCardEntryAge
OBJECT-TYPE
The time, in seconds, that have elapsed since the link state advertisement was originated. The link state advertisement will be purged from the global database when the age reaches MaxAge (1 hour).
1.3.6.1.4.1.711.2.1.15.7.2.1.3LightStreamUpToMaxAgeread-onlymandatory
gidLineCardEntrySeqno
OBJECT-TYPE
The flooding protocol sequence number currently associated with the link state advertisement. The sequence number is a signed 32-bit integer. It is used to detect old and duplicate database announcements. The sequence number space is linearly ordered; the larger the sequence number, the more recent the database announcement.
1.3.6.1.4.1.711.2.1.15.7.2.1.4INTEGERread-onlymandatory
gidLineCardEntryAdvNP
OBJECT-TYPE
The internal card ID of the Network Processor which originated the IP address translation.
1.3.6.1.4.1.711.2.1.15.7.2.1.5INTEGERread-onlymandatory
gidLineCardPorts
OBJECT-TYPE
The number of edge and/or trunk ports attached to the line card. Network processor cards may be advertised as having 0 ports.
1.3.6.1.4.1.711.2.1.15.7.2.1.6INTEGERread-onlymandatory
gidPortTable
OBJECT-TYPE
A table containing information about each network link known to GID. A point-to-point link is represented by two entries in the GID link state database, one for each direction of data transmission.
1.3.6.1.4.1.711.2.1.15.7.3not-accessiblemandatory
gidPortEntry
OBJECT-TYPE
The information regarding a single network link.
1.3.6.1.4.1.711.2.1.15.7.3.1not-accessiblemandatory
gidPortChassis
OBJECT-TYPE
The internal chassis ID of the chassis which contains the line card associated with the port.
1.3.6.1.4.1.711.2.1.15.7.3.1.1INTEGERread-onlymandatory
gidPortID
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.15.7.3.1.2INTEGERread-onlymandatory
gidPortService
OBJECT-TYPE
The operating mode (trunk or edge) of the port.
1.3.6.1.4.1.711.2.1.15.7.3.1.3INTEGER {trunk(1), edge(2)}read-onlymandatory
gidPortUpDown
OBJECT-TYPE
The up/down state of the port.
1.3.6.1.4.1.711.2.1.15.7.3.1.4INTEGER {down(1), up(2)}read-onlymandatory
gidPortBW0
OBJECT-TYPE
The amount of type 0 bandwidth available for reservation for data transmission through the port.
1.3.6.1.4.1.711.2.1.15.7.3.1.5INTEGERread-onlymandatory
gidPortBW1
OBJECT-TYPE
The amount of type 1 bandwidth available for reservation for data transmission through the port.
1.3.6.1.4.1.711.2.1.15.7.3.1.6INTEGERread-onlymandatory
gidPortBW2
OBJECT-TYPE
The amount of type 2 bandwidth available for reservation for data transmission through the port.
1.3.6.1.4.1.711.2.1.15.7.3.1.7INTEGERread-onlymandatory
gidPortRemoteChassis
OBJECT-TYPE
The internal chassis ID of the chassis which contains the line card and port at the remote end of the point-to-point link.
1.3.6.1.4.1.711.2.1.15.7.3.1.8INTEGERread-onlymandatory
gidPortRemotePort
OBJECT-TYPE
This is the ifIndex value of the corresponding ifEntry. See comments above.
1.3.6.1.4.1.711.2.1.15.7.3.1.9INTEGERread-onlymandatory
gidIpAddressGroup
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.15.8
gidIpAddressDatabaseSize
OBJECT-TYPE
The current size of the address translation database, in bytes.
1.3.6.1.4.1.711.2.1.15.8.1INTEGERread-onlymandatory
gidIpAddressTable
OBJECT-TYPE
A table containing information about each internal IP address translation known to GID.
1.3.6.1.4.1.711.2.1.15.8.2not-accessiblemandatory
gidIpAddressEntry
OBJECT-TYPE
The information regarding a single internal IP address translation.
1.3.6.1.4.1.711.2.1.15.8.2.1not-accessiblemandatory
gidInternalIpAddress
OBJECT-TYPE
The internal IP address associated with the IP address translation instance.
1.3.6.1.4.1.711.2.1.15.8.2.1.1IpAddressread-onlymandatory
gidIpEntryAge
OBJECT-TYPE
The time, in seconds, that have elapsed since the IP address translation was originated. The address translation will be purged from the global database when the age reaches MaxAge (1 hour).
1.3.6.1.4.1.711.2.1.15.8.2.1.2LightStreamUpToMaxAgeread-onlymandatory
gidIpEntrySeqno
OBJECT-TYPE
The flooding protocol sequence number currently associated with the IP address translation. The sequence number is a signed 32-bit integer. It is used to detect old and duplicate database announcements. The sequence number space is linearly ordered; the larger the sequence number, the more recent the database announcement.
1.3.6.1.4.1.711.2.1.15.8.2.1.3INTEGERread-onlymandatory
gidIpEntryAdvNP
OBJECT-TYPE
The internal card ID of the Network Processor which originated the IP address translation.
1.3.6.1.4.1.711.2.1.15.8.2.1.4INTEGERread-onlymandatory
gidIpEntryNetMask
OBJECT-TYPE
The IP network mask associated with the IP address translation.
1.3.6.1.4.1.711.2.1.15.8.2.1.5INTEGERread-onlymandatory
gidIpEntryEIA
OBJECT-TYPE
The internal address of the network port associated with the IP address translation.
1.3.6.1.4.1.711.2.1.15.8.2.1.6OCTET STRING (SIZE(6))read-onlymandatory
gidEventGroup
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.15.9
gidEventLinkEventsDelivered
OBJECT-TYPE
The number of link events delivered by GID since initialization.
1.3.6.1.4.1.711.2.1.15.9.1Counterread-onlymandatory
gidEventIpEventsDelivered
OBJECT-TYPE
The number of internal IP events delivered by GID since initialization.
1.3.6.1.4.1.711.2.1.15.9.2Counterread-onlymandatory
gidEventGenericGinfoEventsDelivered
OBJECT-TYPE
The number of generic global information events delivered by GID since initialization.
1.3.6.1.4.1.711.2.1.15.9.3Counterread-onlymandatory
gidEventGenericGinfoEventTable
OBJECT-TYPE
A table containing the number of generic global information events transmitted by GID since initialization. The table is indexed by distribution group.
1.3.6.1.4.1.711.2.1.15.9.4not-accessiblemandatory
gidEventGenericGinfoEventCount
OBJECT-TYPE
The number of generic global information events delivered to clients in this distribution group.
1.3.6.1.4.1.711.2.1.15.9.4.1not-accessiblemandatory
gidEventDistributionGroup
OBJECT-TYPE
The flooding protocol distribution group to which the events were delivered.
1.3.6.1.4.1.711.2.1.15.9.4.1.1INTEGERread-onlymandatory
gidEventGenericGinfoEvents
OBJECT-TYPE
The number of events delivered to clients in the distribution group.
1.3.6.1.4.1.711.2.1.15.9.4.1.2Counterread-onlymandatory
lsPID
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.16
pidTable
OBJECT-TYPE
PID table of current pids
1.3.6.1.4.1.711.2.1.16.1not-accessiblemandatory
pidEntry
OBJECT-TYPE
An entry in the PPID table.
1.3.6.1.4.1.711.2.1.16.1.1not-accessiblemandatory
pidIndex
OBJECT-TYPE
Unique Index consisting of PID number.
1.3.6.1.4.1.711.2.1.16.1.1.1INTEGERread-onlymandatory
pidName
OBJECT-TYPE
Process Name.
1.3.6.1.4.1.711.2.1.16.1.1.2DisplayStringread-onlymandatory
pidCreationTime
OBJECT-TYPE
Time since process creation in seconds.
1.3.6.1.4.1.711.2.1.16.1.1.3INTEGERread-onlymandatory
pidOperStatus
OBJECT-TYPE
Operation Status of process.
1.3.6.1.4.1.711.2.1.16.1.1.4INTEGER {up(1), down(2)}read-onlymandatory
pidAdminStatus
OBJECT-TYPE
Administratively desired state of process.
1.3.6.1.4.1.711.2.1.16.1.1.5INTEGER {up(1), down(2)}read-writemandatory
lsND
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.17
ndGeneralGroup
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.17.1
ndSoftwareVersionNumber
OBJECT-TYPE
The neighborhood discovery (ND) process software revision number
1.3.6.1.4.1.711.2.1.17.1.1DisplayStringread-onlymandatory
ndProcessID
OBJECT-TYPE
The ND process ID.
1.3.6.1.4.1.711.2.1.17.1.2INTEGERread-onlymandatory
ndMemoryUse
OBJECT-TYPE
The total amount of dynamically allocated memory (in bytes) currently allocated by the ND process for all purposes.
1.3.6.1.4.1.711.2.1.17.1.4Counterread-onlymandatory
ndTimersProcessed
OBJECT-TYPE
The number of timers processed by the ND process since initialization.
1.3.6.1.4.1.711.2.1.17.1.5Counterread-onlymandatory
ndLCGroup
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.17.2
ndLCCount
OBJECT-TYPE
The number of line cards managed by the NP.
1.3.6.1.4.1.711.2.1.17.2.1Counterread-onlymandatory
ndLCTable
OBJECT-TYPE
A table containing information about each managed line card neighbor.
1.3.6.1.4.1.711.2.1.17.2.2not-accessiblemandatory
ndLCEntry
OBJECT-TYPE
The information regarding a single ND neighbor.
1.3.6.1.4.1.711.2.1.17.2.2.1not-accessiblemandatory
ndLCEIA
OBJECT-TYPE
The internal address of the managed line card.
1.3.6.1.4.1.711.2.1.17.2.2.1.1INTEGERread-onlymandatory
ndLCChannel
OBJECT-TYPE
The reliable channel to the managed line card.
1.3.6.1.4.1.711.2.1.17.2.2.1.2INTEGERread-onlymandatory
ndLCState
OBJECT-TYPE
The line card's state.
1.3.6.1.4.1.711.2.1.17.2.2.1.3INTEGER {unknown(1), existent(2), up(3), comingdown(4)}read-onlymandatory
ndNbrGroup
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.17.3
ndNbrCount
OBJECT-TYPE
The number of neighbor NPs known to the ND process.
1.3.6.1.4.1.711.2.1.17.3.1Counterread-onlymandatory
ndNbrTable
OBJECT-TYPE
A table containing information about each ND neighbor.
1.3.6.1.4.1.711.2.1.17.3.2not-accessiblemandatory
ndNbrEntry
OBJECT-TYPE
The information regarding a single ND neighbor.
1.3.6.1.4.1.711.2.1.17.3.2.1not-accessiblemandatory
ndNbrEIA
OBJECT-TYPE
The internal address of the neighbor NP.
1.3.6.1.4.1.711.2.1.17.3.2.1.1INTEGERread-onlymandatory
ndNbrChannel
OBJECT-TYPE
The reliable channel to the neighbor.
1.3.6.1.4.1.711.2.1.17.3.2.1.2INTEGERread-onlymandatory
ndNbrState
OBJECT-TYPE
The neighbor's state.
1.3.6.1.4.1.711.2.1.17.3.2.1.3INTEGER {unknown(1), existent(2), up(3), comingdown(4)}read-onlymandatory
ndSwudGroup
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.17.4
ndSwudTable
OBJECT-TYPE
A table containing switch up/down protocol parameters for each switch slot.
1.3.6.1.4.1.711.2.1.17.4.1not-accessiblemandatory
ndSwudEntry
OBJECT-TYPE
The switch up/down protocol parameters for a single switch slot.
1.3.6.1.4.1.711.2.1.17.4.1.1not-accessiblemandatory
ndSwudIndex
OBJECT-TYPE
The switch slot to which the parameters correspond.
1.3.6.1.4.1.711.2.1.17.4.1.1.1INTEGERread-onlymandatory
ndOperIntvl
OBJECT-TYPE
The operational interval between switch up/down messages sent by ND to this slot, in units of 100 milliseconds.
1.3.6.1.4.1.711.2.1.17.4.1.1.2INTEGERread-onlymandatory
ndOperJ
OBJECT-TYPE
The operational J parameter for this slot.
1.3.6.1.4.1.711.2.1.17.4.1.1.3INTEGERread-onlymandatory
ndOperK
OBJECT-TYPE
The operational K parameter for this slot.
1.3.6.1.4.1.711.2.1.17.4.1.1.4INTEGERread-onlymandatory
ndOperM
OBJECT-TYPE
The operational M parameter for this slot.
1.3.6.1.4.1.711.2.1.17.4.1.1.5INTEGERread-onlymandatory
ndOperN
OBJECT-TYPE
The operational N parameter for this slot.
1.3.6.1.4.1.711.2.1.17.4.1.1.6INTEGERread-onlymandatory
ndAdminIntvl
OBJECT-TYPE
The administratively desired interval between switch up/down messages sent by ND to this slot, in units of 100 milliseconds.
1.3.6.1.4.1.711.2.1.17.4.1.1.7INTEGERread-writemandatory
ndAdminJ
OBJECT-TYPE
The administratively desired J parameter for this slot.
1.3.6.1.4.1.711.2.1.17.4.1.1.8INTEGERread-writemandatory
ndAdminK
OBJECT-TYPE
The administratively desired K parameter for this slot.
1.3.6.1.4.1.711.2.1.17.4.1.1.9INTEGERread-writemandatory
ndAdminM
OBJECT-TYPE
The administratively desired M parameter for this slot.
1.3.6.1.4.1.711.2.1.17.4.1.1.10INTEGERread-writemandatory
ndAdminN
OBJECT-TYPE
The administratively desired N parameter for this slot.
1.3.6.1.4.1.711.2.1.17.4.1.1.11INTEGERread-writemandatory
ndTrigger
OBJECT-TYPE
Transfer administratively desired to operational parameters.
1.3.6.1.4.1.711.2.1.17.4.1.1.12INTEGERread-writemandatory
ndSwudStatsInputErrors
OBJECT-TYPE
The number of errors received on switch up/down input cells.
1.3.6.1.4.1.711.2.1.17.4.2Counterread-onlymandatory
ndSwudStatsTable
OBJECT-TYPE
A table containing switch up/down protocol statistics for each switch slot.
1.3.6.1.4.1.711.2.1.17.4.3not-accessiblemandatory
ndSwudStatsEntry
OBJECT-TYPE
Switch up/down protocol statistics for a single switch slot.
1.3.6.1.4.1.711.2.1.17.4.3.1not-accessiblemandatory
ndSwudStatsIndex
OBJECT-TYPE
The switch slot to which the statistics correspond.
1.3.6.1.4.1.711.2.1.17.4.3.1.1INTEGERread-onlymandatory
ndInputCells
OBJECT-TYPE
The number of switch up/down cells received from this switch slot.
1.3.6.1.4.1.711.2.1.17.4.3.1.2Counterread-onlymandatory
ndInputErrs
OBJECT-TYPE
The number of errored switch up/down cells received from this switch slot.
1.3.6.1.4.1.711.2.1.17.4.3.1.3Counterread-onlymandatory
ndOutputCells
OBJECT-TYPE
The number of switch up/down cells sent to this switch slot.
1.3.6.1.4.1.711.2.1.17.4.3.1.4Counterread-onlymandatory
ndOutputErrs
OBJECT-TYPE
The number of errors reported on switch up/down cells sent to this switch slot.
1.3.6.1.4.1.711.2.1.17.4.3.1.5Counterread-onlymandatory
ndClientGroup
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.17.5
ndClientCount
OBJECT-TYPE
The number of registered ND client processes.
1.3.6.1.4.1.711.2.1.17.5.1Counterread-onlymandatory
ndClientTable
OBJECT-TYPE
A table containing information about each ND client process.
1.3.6.1.4.1.711.2.1.17.5.2not-accessiblemandatory
ndClientEntry
OBJECT-TYPE
The information regarding a single ND client process.
1.3.6.1.4.1.711.2.1.17.5.2.1not-accessiblemandatory
ndClientID
OBJECT-TYPE
The ND client process identifier.
1.3.6.1.4.1.711.2.1.17.5.2.1.1INTEGERread-onlymandatory
ndClientType
OBJECT-TYPE
The ND client type.
1.3.6.1.4.1.711.2.1.17.5.2.1.2INTEGER {nd(3), gid(4), lcc(5), ca(6), sys(7)}read-onlymandatory
ndClientSubType
OBJECT-TYPE
The ND client subtype, if applicable. Certain processes with the same major type, e.g. sys, are distinguished by differing subtypes.
1.3.6.1.4.1.711.2.1.17.5.2.1.3INTEGERread-onlymandatory
ndClientEIA
OBJECT-TYPE
The internal card address associated with the ND client process, if applicable. Edge and trunk card control processes are associated with a unique card address. The NP card control process and the Congestion Avoidance information distribution process share the internal card address of the local NP.
1.3.6.1.4.1.711.2.1.17.5.2.1.4INTEGERread-onlymandatory
ndClientRegistration
OBJECT-TYPE
A mask of events for which the ND client is registered.
1.3.6.1.4.1.711.2.1.17.5.2.1.5INTEGERread-onlymandatory
ndInternalGroup
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.17.6
ndInternalDebugLevel
OBJECT-TYPE
ND internal debugging variable.
1.3.6.1.4.1.711.2.1.17.6.1INTEGERread-writemandatory
ndInternalDebugFlags
OBJECT-TYPE
ND internal debugging variable.
1.3.6.1.4.1.711.2.1.17.6.2INTEGERread-writemandatory
ndRedundancyGroup
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.17.7
ndPrimaryNP
OBJECT-TYPE
Slot number of primary NP.
1.3.6.1.4.1.711.2.1.17.7.1INTEGERread-onlymandatory
ndThisNP
OBJECT-TYPE
Slot number of currently connected NP.
1.3.6.1.4.1.711.2.1.17.7.2INTEGERread-onlymandatory
ndForceToBackup
OBJECT-TYPE
Force this NP to become backup.
1.3.6.1.4.1.711.2.1.17.7.3INTEGERread-writemandatory
lwmaInfo
OBJECT-IDENTITY
1.3.6.1.4.1.711.2.1.18
lwmaTable
OBJECT-TYPE
Table of perprocess LWMA private info
1.3.6.1.4.1.711.2.1.18.1not-accessiblemandatory
lwmaEntry
OBJECT-TYPE
An entry in the LWMA table.
1.3.6.1.4.1.711.2.1.18.1.1not-accessiblemandatory
lwmaIndex
OBJECT-TYPE
Unique Index consisting of LWMA number.
1.3.6.1.4.1.711.2.1.18.1.1.1INTEGERread-onlymandatory
lwmaCreationTime
OBJECT-TYPE
Unix time in seconds marking start of MMA.
1.3.6.1.4.1.711.2.1.18.1.1.2INTEGERread-onlymandatory
lwmaTableNotification
OBJECT-TYPE
Object-ID of last table completing configuration
1.3.6.1.4.1.711.2.1.18.1.1.3OBJECT IDENTIFIERread-onlymandatory
lwmaTrapLevel
OBJECT-TYPE
Trap filter level for the lwma.
1.3.6.1.4.1.711.2.1.18.1.1.4INTEGER {operational(1), informational(2), trace(3), debug(4)}read-writemandatory
lwmaTrapNumber
OBJECT-TYPE
Trap Number used by the state and action variables
1.3.6.1.4.1.711.2.1.18.1.1.5INTEGERread-writemandatory
lwmaTrapOnOffState
OBJECT-TYPE
On/Off State of Trap specified in lwmaTrapNumber
1.3.6.1.4.1.711.2.1.18.1.1.6INTEGER {trapOn(1), trapOff(2)}read-writemandatory
lwmaTrapCliAlias
OBJECT-TYPE
Name for this process that can be used in the CLI trap interface.
1.3.6.1.4.1.711.2.1.18.1.1.7OCTET STRING (SIZE(32))read-onlymandatory
lightStreamInternet
OBJECT-IDENTITY
1.3.6.1.4.1.711.3
lightStreamBridge
OBJECT-IDENTITY
1.3.6.1.4.1.711.3.1
lightStreamBridgePortTable
OBJECT-TYPE
Proprietary port parameters needed for LightStream node configuration. This table contains one entry for each bridge port.
1.3.6.1.4.1.711.3.1.1not-accessiblemandatory
lightStreamBridgePortEntry
OBJECT-TYPE
Objects required for a given bridge port.
1.3.6.1.4.1.711.3.1.1.1not-accessiblemandatory
lightStreamBrPortPort
OBJECT-TYPE
The value of the instance of the dot1dBasePort object, defined in the standard Bridge MIB (RFC1286), for the port this entry corresponds to.
1.3.6.1.4.1.711.3.1.1.1.1INTEGERread-onlymandatory
lightStreamBrPortDefaultAction
OBJECT-TYPE
This is the action taken on frames received that do not match a defined filter.
1.3.6.1.4.1.711.3.1.1.1.2LightStreamFilterActionread-writemandatory
lightStreamBrPortBcastRateLimit
OBJECT-TYPE
Number of broadcast packets that this node forwards per second. The node discards all additional packets per second. If the value is zero, all broadcast packets are discarded. If the value is -1 all broadcast packets are forwarded. That is, there is no limit on broadcasts.
1.3.6.1.4.1.711.3.1.1.1.3INTEGER (-1..127)read-writemandatory
lightStreamBrPortDroppedBcastPkts
OBJECT-TYPE
The number of broadcast packets dropped because the lightStreamBrPortBcastRateLimit was exceeded.
1.3.6.1.4.1.711.3.1.1.1.4Counterread-onlymandatory
lightStreamBridgeFilterTable
OBJECT-TYPE
A list of filters. Reverse Polish Notation (RPN) is being used here to provide the most flexibility in defining more complex filters in the future. Each filter is represented by a list of entries. Each entry is a single RPN token. To create an entry, create the list of tokens as follows: More than one token can be contained in a single message. All fields of a single token must be in the same message. The lightStreamBrFilterStatus object of all intermediate tokens must contain the value 'intermediateToken'. The lightStreamBrFilterStatus object of the last token must contain the value 'complete'. When the last token is created with a status of 'complete' the status field of every prior token associated with that filter is set to 'complete'. When the filter is set to 'complete', it is available for use in a lightStreamBridgeFilterParameterEntry. The filter is not actually used until its ID is placed in a lightStreamBridgeFilterParameterEntry and the associated parameters are defined. A filter may be used more than once in the lightStreamBridgeFilterParameterTable. The agent does not permit the user to 'delete' the filter entry until it is removed from the lightStreamBridgeFilterParameterTable. When a filter is placed into or removed from the lightStreamBridgeFilterParameterTable, its new state becomes active immediately. The agent provides timeout service for partially constructed filters. If a manager doesn't complete a filter definition within the timeout period (currently 3 minutes), the agent removes all tokens associated with that filter.
1.3.6.1.4.1.711.3.1.2not-accessiblemandatory
lightStreamBridgeFilterEntry
OBJECT-TYPE
A single filter consists of multiple lightStreamBridgeFilterEntries. Each entry represents a single token of a given filter.
1.3.6.1.4.1.711.3.1.2.1not-accessiblemandatory
lightStreamBrFilterId
OBJECT-TYPE
The ID assigned to this filter.
1.3.6.1.4.1.711.3.1.2.1.1INTEGER (1..65535)read-onlymandatory
lightStreamBrFilterTokenIndex
OBJECT-TYPE
The RPN index of this token within the filter. This value must be assigned sequentially starting with 1.
1.3.6.1.4.1.711.3.1.2.1.2INTEGERread-onlymandatory
lightStreamBrFilterTokenType
OBJECT-TYPE
This defines the type of token contained in this entry. There is no default value for this object, its value must be contained in the creation message.
1.3.6.1.4.1.711.3.1.2.1.3INTEGER {operation(1), frameField(2), macAddrType(3), etherType(4), llcSAPType(5), reserved(6), snapOuiType(7)}read-writemandatory
lightStreamBrFilterTokenValue
OBJECT-TYPE
The value for this token. The appropriate value depends on the lightStreamBrFilterTokenType. Because instances of this object can be of diverse types, they are exchanged as DisplayStrings and the agent parses it according to the type. If the type is 'operation', the agent expects one of the following character strings: maskAnd and or equal notEqual greater greaterOrEqual less lessOrEqual If the type is 'macAddrType' the agent expects a MAC address DisplayString in the format xx:xx:xx:xx:xx:xx. If the type is 'frameField' the agent will expect of one of the following character strings: macSrc macDst macProto llcSSAP llcDSAP snapOUI snapProto For all other types, the agent expects a hex digit displayString in the form 0x800. This object has no default value. It must be explicitly set in the creation message.
1.3.6.1.4.1.711.3.1.2.1.4DisplayStringread-writemandatory
lightStreamBrFilterStatus
OBJECT-TYPE
To define an interim token, set this field to 'intermediateToken'. To define the final token set this field to 'complete'. This has the side-effect of setting the lightStreamBrFilterStatus fields of all tokens for this filter to 'complete'. To delete an unassigned filter, set this value to 'delete' in any of the filter's token entries. This has the side-effect of setting the lightStreamBrFilterStatus fields of all tokens for this filter to 'delete'. This object does not have a default value. To create an entry this object must be explicitly contained in the set message.
1.3.6.1.4.1.711.3.1.2.1.5INTEGER {complete(1), delete(2), intermediateToken(4)}read-writemandatory
lightStreamBridgeFilterParameterTable
OBJECT-TYPE
This table contains the list of assigned filters and the parameters associated with it. To add an entry to this table, all non-defaulted objects must be contained in a single message and the lightStreamBrFilterParmFilterId must already be created in the lightStreamBridgeFilterTable.
1.3.6.1.4.1.711.3.1.3not-accessiblemandatory
lightStreamBridgeFilterParameterEntry
OBJECT-TYPE
The objects associated with a single assigned filter.
1.3.6.1.4.1.711.3.1.3.1not-accessiblemandatory
lightStreamBrFilterParmPort
OBJECT-TYPE
The dot1dBasePort, defined in the standard Bridge MIB (RFC1286), this entry is defined for.
1.3.6.1.4.1.711.3.1.3.1.1INTEGERread-onlymandatory
lightStreamBrFilterParmFilterId
OBJECT-TYPE
The lightStreamBrFilterId being assigned here.
1.3.6.1.4.1.711.3.1.3.1.2INTEGERread-onlymandatory
lightStreamBrFilterParmFilterPriority
OBJECT-TYPE
The precedence assigned to this filter. The value 1 gives the object the highest priority on this port. It is recommended that these not be assigned sequentially. Sequential numbering would make it difficult to re-prioritize the filters.
1.3.6.1.4.1.711.3.1.3.1.3INTEGERread-writemandatory
lightStreamBrFilterParmAction
OBJECT-TYPE
Definition of what action should be taken when a packet matching this filter is encountered.
1.3.6.1.4.1.711.3.1.3.1.4LightStreamFilterActionread-writemandatory
lightStreamBrFilterParmMatchCounts
OBJECT-TYPE
The number of times this filter instance was matched.
1.3.6.1.4.1.711.3.1.3.1.5Counterread-onlymandatory
lightStreamBrFilterParmValidation
OBJECT-TYPE
This object indicates whether the user has validated or invalidated this entry. This entry does not have a default value. To create an entry this object must be explicitly contained in the set message.
1.3.6.1.4.1.711.3.1.3.1.6LightStreamValidationread-writemandatory
lightStreamBrStaticGoToCardSize
OBJECT-TYPE
This object indicates how many bytes of the bit string dot1dStaticGoTo represent a single card. There must be enough bytes to represent all the ports on a card, and this is release specific. The dot1dStaticGoTo object is a bit string that represents the bridging ports on the LightStream Node.
1.3.6.1.4.1.711.3.1.4INTEGERread-onlymandatory
lightStreamVli
OBJECT-IDENTITY
1.3.6.1.4.1.711.4
lightStreamVliVersion
OBJECT-TYPE
The version of VLI implemented in this node.
1.3.6.1.4.1.711.4.1INTEGER {version-1(1)}read-onlymandatory
lightStreamVliPortCtlTable
OBJECT-TYPE
This table contains the control information for port based VLI.
1.3.6.1.4.1.711.4.4not-accessiblemandatory
lightStreamVliPortCtlEntry
OBJECT-TYPE
Information needed to manage port based VLI on a given bridge port.
1.3.6.1.4.1.711.4.4.1not-accessiblemandatory
lightStreamVliPortCtlPort
OBJECT-TYPE
The bridge port this entry corresponds to. This value is the same as dot1dBasePort which is defined in the IETF standard Bridge MIB.
1.3.6.1.4.1.711.4.4.1.1INTEGERread-onlymandatory
lightStreamVliPortCtlMode
OBJECT-TYPE
This defines the type of control to be instrumented on this port. include: When this object is set to include, port based VLI will process only the work groups defined in the corresponding work group table entries. All other work groups will be filtered out on this port. exclude: When this object is set to exclude, port based VLI will process all work groups except those listed in the corresponding work group table entries. Those listed in the lightStreamVliPortWorkGroupTable will be filtered. The default state of exclude with an empty work group table allows all work groups to be recognized as valid on this port.
1.3.6.1.4.1.711.4.4.1.2INTEGER {include(1), exclude(2)}read-writemandatory
lightStreamVliPortWorkGroupTable
OBJECT-TYPE
The list of work groups defined for port based VLI management.
1.3.6.1.4.1.711.4.5not-accessiblemandatory
lightStreamVliPortWorkGroupEntry
OBJECT-TYPE
A work group to port association.
1.3.6.1.4.1.711.4.5.1not-accessiblemandatory
lightStreamVliPortWorkGroupPort
OBJECT-TYPE
The port this work group is being defined on. This value is the same as dot1dBasePort.
1.3.6.1.4.1.711.4.5.1.1INTEGERread-onlymandatory
lightStreamVliPortWorkGroupID
OBJECT-TYPE
The identifier of the work group being assigned to this port. This must have a corresponding entry in the lightStreamVliWorkGroupTable.
1.3.6.1.4.1.711.4.5.1.2INTEGER (1..65535)read-onlymandatory
lightStreamVliPortWorkGroupValidation
OBJECT-TYPE
For conceptual row addition, this table requires all non-defaulted objects for a given entry to be contained in a single SNMP message. This object will not default. To create a new entry, this object must be explicitly set to valid. To remove an entry, this object must be explicitly set to invalid.
1.3.6.1.4.1.711.4.5.1.3LightStreamValidationread-writemandatory
lightStreamEOM
OBJECT-IDENTITY
1.3.6.1.4.1.711.1000
lightStreamEndOfMib
OBJECT-TYPE
Always returns 1.
1.3.6.1.4.1.711.1000.1INTEGERread-onlymandatory