Description

The MIB module used to specify Liebert Controller OIDs Copyright 2000-2008 Liebert Corporation. All rights reserved. Reproduction of this document is authorized on the condition that the forgoing copyright notice is included. This Specification is supplied 'AS IS' and Liebert Corporation makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification.

Contact

Contact: Technical Support Postal: Liebert Corporation 1050 Dearborn Drive P.O. Box 29186 Columbus OH, 43229 US Tel: +1 (800) 222-5877 E-mail: liebert.monitoring@vertivco.com Web: www.vertivco.com Author: Gregory M. Hoge

Imports

FromSymbols
LIEBERT-GP-AGENT-MIBlgpAgentConnectedDeviceCount, lgpAgentDeviceIndex
LIEBERT-GP-REGISTRATION-MIBlgpSystem, liebertSystemModuleReg
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-MIBsysUpTime
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

LIEBERT-GP-AGENT-MIB
LIEBERT-GP-CONDITIONS-MIB
LIEBERT-GP-REGISTRATION-MIB
LIEBERT-GP-SYSTEM-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
lgpSysStatistics
OBJECT-IDENTITY
This sub-tree is used to register Liebert System Statistics object identifiers.
1.3.6.1.4.1.476.1.42.3.7.1current
lgpSysStatisticsRunHrs
OBJECT-TYPE
Accumulated run hours of the system.
1.3.6.1.4.1.476.1.42.3.7.1.1Unsigned32read-onlycurrent
lgpSysStatus
OBJECT-IDENTITY
This sub-tree is used to register Liebert System Status object identifiers.
1.3.6.1.4.1.476.1.42.3.7.2current
lgpSysSelfTestResult
OBJECT-TYPE
The outcome of the previous self-test.
1.3.6.1.4.1.476.1.42.3.7.2.1INTEGER {unknown(1), passed(2), failed(3), inProgress(4), sysFailure(5), inhibited(6)}read-onlycurrent
lgpSysState
OBJECT-TYPE
The operating status for the system. The intent of this data is to provide a high level status of the system. The possible states are: normalOperation(1) The system is operating normally with no active warnings or alarms. startUp(2) The system is in a startup state (initializing). Monitoring operations and information may not be fully supported at this time. This state will clear automatically when the system is fully initialized and ready to accept monitoring commands. normalWithWarning(3) The system is operating normally with one or more active warnings. Appropriate personnel should investigate the warning(s) as soon as possible and take appropriate action. normalWithAlarm(4) The system is operating normally with one or more active alarms. Appropriate personnel should investigate the alarm(s) as soon as possible and take appropriate action. abnormalOperation(5) They system is operating abnormally. There is a failure within the system that is unexpected under normal operating conditions. Appropriate personnel should investigate the cause as soon as possible. The normal functioning of the system is likely inhibited.
1.3.6.1.4.1.476.1.42.3.7.2.2INTEGER {normalOperation(1), startUp(2), normalWithWarning(3), normalWithAlarm(4), abnormalOperation(5)}read-onlycurrent
lgpSysSettings
OBJECT-IDENTITY
This sub-tree is used to register Liebert System Settings object identifiers.
1.3.6.1.4.1.476.1.42.3.7.3current
lgpSysAudibleAlarm
OBJECT-TYPE
The state of the audible alarm of the device.
1.3.6.1.4.1.476.1.42.3.7.3.1INTEGER {on(1), off(2)}read-writecurrent
lgpSysControl
OBJECT-IDENTITY
This sub-tree is used to register Liebert System Control object identifiers.
1.3.6.1.4.1.476.1.42.3.7.4current
lgpSysSelfTest
OBJECT-TYPE
Self-Test Command. This command will initiate a system self-test of the system. If already initiated, this command will abort the self-test. This command should be sent with a parameter of 1. This variable doesn't return a value when read.
1.3.6.1.4.1.476.1.42.3.7.4.1Integer32read-writecurrent
lgpSysControlOperationOnOff
OBJECT-TYPE
This object allows control of the system functionality. This will not affect the communications or control of the system, so that once turned off, the system operation can be restored by setting this value to 'on'.
1.3.6.1.4.1.476.1.42.3.7.4.2INTEGER {on(1), off(2)}read-writecurrent
lgpSysTime
OBJECT-IDENTITY
This sub-tree is used to register Liebert System Time object identifiers.
1.3.6.1.4.1.476.1.42.3.7.5current
lgpSysTimeEpoch
OBJECT-TYPE
The present time of the system. This time is represented as the number of seconds since the epoch of 1970-01-01 00:00:00 GMT.
1.3.6.1.4.1.476.1.42.3.7.5.1Unsigned32read-writecurrent
lgpSysMaintenance
OBJECT-IDENTITY
This sub-tree is used to register Liebert System Maintenance object identifiers.
1.3.6.1.4.1.476.1.42.3.7.6current
lgpSysMaintenanceCapacity
OBJECT-TYPE
The relative percentage of time that has elapsed since the last scheduled maintenance was performed. When this value reaches 100%, the device is due for another scheduled maintenance procedure.
1.3.6.1.4.1.476.1.42.3.7.6.1Unsigned32read-onlycurrent
lgpSysMaintenanceYear
OBJECT-TYPE
The year in which the next scheduled service is due
1.3.6.1.4.1.476.1.42.3.7.6.2Unsigned32read-onlycurrent
lgpSysMaintenanceMonth
OBJECT-TYPE
The month in which the next scheduled service is due
1.3.6.1.4.1.476.1.42.3.7.6.3Unsigned32read-onlycurrent
lgpSysEventDescription
OBJECT-TYPE
An ASCII textual description for the event. This object is primarily used in the varbind of some notifications to provide a simple human-readable description.
1.3.6.1.4.1.476.1.42.3.7.7DisplayString (SIZE(255))read-onlycurrent
lgpSysEventNotifications
OBJECT-IDENTITY
This sub-tree is used to register Liebert System Notification object identifiers.
1.3.6.1.4.1.476.1.42.3.7.8current
lgpSysDeviceComponentGroup
OBJECT-IDENTITY
This sub-tree registers well known device components.
1.3.6.1.4.1.476.1.42.3.7.9current
lgpSysDeviceComponentTable
OBJECT-TYPE
A list of components of devices identified by their serial number and or model number. This table contains zero, one, or many rows. The NMS cannot create or delete rows from the table. The rows are created by the agent based upon the capabilities of the managed device.
1.3.6.1.4.1.476.1.42.3.7.9.1not-accessiblecurrent
lgpSysDeviceComponentEntry
OBJECT-TYPE
This entry defines the contents of the columns for the table 'lgpSysDeviceComponentTable'.
1.3.6.1.4.1.476.1.42.3.7.9.1.1not-accessiblecurrent
lgpSysDeviceComponentIndex
OBJECT-TYPE
This is the index indicating the row in the table 'lgpSysDeviceComponentTable' for a component entry.
1.3.6.1.4.1.476.1.42.3.7.9.1.1.1Unsigned32not-accessiblecurrent
lgpSysDeviceComponentDescr
OBJECT-TYPE
An OID representing a component of the device indicated by the index lgpAgentDeviceIndex.
1.3.6.1.4.1.476.1.42.3.7.9.1.1.2OBJECT IDENTIFIERread-onlycurrent
lgpSysDeviceComponentSerialNum
OBJECT-TYPE
This is the serial number of the component described by the OID 'lgpSysDeviceComponentDescr'. This data is intended for display / human consumption. Do not use this field for determining programmatic behavior.
1.3.6.1.4.1.476.1.42.3.7.9.1.1.3DisplayString (SIZE(255))read-onlycurrent
lgpSysDeviceComponentModelNum
OBJECT-TYPE
This is the model identifier of the component described by the OID 'lgpSysDeviceComponentDescr'. This data is intended for display / human consumption. Do not use this field for determining programmatic behavior.
1.3.6.1.4.1.476.1.42.3.7.9.1.1.4DisplayString (SIZE(255))read-onlycurrent
lgpSysDeviceComponentWellknown
OBJECT-IDENTITY
This sub-tree registers well known Liebert System Components.
1.3.6.1.4.1.476.1.42.3.7.9.5current
lgpSysDeviceBatCabinet
OBJECT-IDENTITY
This sub-tree is used to register a battery cabinet component. To determine the cabinet being described in a multi-cabinet system, this point implements an additional two indexes. The first index describes the module the cabinet is located in. The second index describes the cabinet number. In an SMS (Single-Module System) the first index is always 1. Example: lgpSysDeviceComponentCabinet.2.4 'lgpSysDeviceCabinet' = Point is a battery cabinet. '.2' = Cabinet is in the second module. '.4' = Cabinet number 4 in second module
1.3.6.1.4.1.476.1.42.3.7.9.5.5current
lgpSysDeviceParallelCabinet
OBJECT-IDENTITY
This sub-tree is used to register a parallel cabinet.
1.3.6.1.4.1.476.1.42.3.7.9.5.6current
lgpSysDeviceMaintBypass
OBJECT-IDENTITY
This sub-tree is used to register the maintenance bypass.
1.3.6.1.4.1.476.1.42.3.7.9.5.7current

Notifications

NameOIDStatus
lgpSysNotification
NOTIFICATION-TYPE
This notification is a generic notification intended for direct user visibility. The user event description identifies the system condition that has occurred. This text will be prefixed with either 'Active:', 'Cleared:', or 'Message:' depending on the state of the event. Note: That a prefix of 'Message:' identifies a stateless event and as such there will be no corresponding 'Cleared:' trap sent.
1.3.6.1.4.1.476.1.42.3.7.8.1current
lgpSysNormal
NOTIFICATION-TYPE
The system has returned to a normal operating state. This implies prior to the generation of this event the system was operating in a state where one or more alarm or warning conditions were present. All of those alarms or conditions have now cleared. NOTE: This notification may be generated after a short delay during a cold boot of the system -- if no alarms or conditions are present in the monitored device(s) at that time.
1.3.6.1.4.1.476.1.42.3.7.8.2current