MIBs Depot

LEA-SMART-SPLITTER-MIB

Registered at
1.3.6.1.4.1.14841.1.1
Last updated
2002-10-04 00:00
Organization
www.leacom.fr
Revisions
2002-09-26 00:00
Namespace
zhone
Source file
LEA-SMART-SPLITTER-MIB
Digest
sha256:abf7e721e909612c5895cf369320465dfef32e43651d933159977fafc6f7058d

Description

LEA Smart Splitter Management Information Base

Contact

postal: Regis Urvoy 52/54 rue du capitaine Guynemer 92415 Courbevoie Cedex France email: regis.urvoy@leacom.fr

Imports

FromSymbols
LEA-MIBleaSplitters
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

LEA-MIB
LEA-SMART-SPLITTER-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
splitterRelay
OBJECT-IDENTITY
1.3.6.1.4.1.14841.1.1.1
relayActiveDuration
OBJECT-TYPE
Duration that a bypass relay is active in seconds. As a fail-safe mechanism, the relay will automatically return a line back to normal operational mode when this timer has expired. The same relay timer value will be used for every port.
1.3.6.1.4.1.14841.1.1.1.1INTEGER (1..300)read-writecurrent
numberOfActiveRelays
OBJECT-TYPE
Total count of active relays. The agent controls the number of active relays so that the maximum is not exceeded in order to keep power consumption down.
1.3.6.1.4.1.14841.1.1.1.2INTEGER (1..15)read-onlycurrent
heartBeat
OBJECT-TYPE
This parameter returns a simply acknowledge following a request from the manager.
1.3.6.1.4.1.14841.1.1.1.3INTEGER {ack(1)}read-onlycurrent
relayTable
OBJECT-TYPE
Table of relay status
1.3.6.1.4.1.14841.1.1.1.4not-accessiblecurrent
relayTableEntry
OBJECT-TYPE
A row describing a relay status
1.3.6.1.4.1.14841.1.1.1.4.1not-accessiblecurrent
relayIndex
OBJECT-TYPE
The index of the table. Its value is (relaySlot-1)*24+relayPort
1.3.6.1.4.1.14841.1.1.1.4.1.1Integer32not-accessiblecurrent
relaySlot
OBJECT-TYPE
The slot being addressed
1.3.6.1.4.1.14841.1.1.1.4.1.2INTEGER {Slot-1(1), Slot-2(2), Slot-3(3), Slot-4(4), Slot-5(5), Slot-6(6), Slot-7(7), Slot-8(8), Slot-9(9), Slot-10(10), Slot-11(11), Slot-12(12), Slot-13(13), Slot-14(14), Slot-15(15)}read-onlycurrent
relayPort
OBJECT-TYPE
The port being addressed
1.3.6.1.4.1.14841.1.1.1.4.1.3INTEGER {Port-1(1), Port-2(2), Port-3(3), Port-4(4), Port-5(5), Port-6(6), Port-7(7), Port-8(8), Port-9(9), Port-10(10), Port-11(11), Port-12(12), Port-13(13), Port-14(14), Port-15(15), Port-16(16), Port-17(17), Port-18(18), Port-19(19), Port-20(20), Port-21(21), Port-22(22), Port-23(23), Port-24(24)}read-onlycurrent
relayStatus
OBJECT-TYPE
This parameter describes whether a particular POTS line is in a normal or closed loop condition. By setting this parameter, the manager can switch the relays in order to bypass the LPF (Low Pass Filter) for POTS closed loop testing (closed) or force a relay back to normal operation mode before the Relay Active Duration timer times out (normal)
1.3.6.1.4.1.14841.1.1.1.4.1.4INTEGER {normal(1), closed(2)}read-writecurrent
relayResetAll
OBJECT-TYPE
This parameter would allow the operator to force a relay back to normal operation for all ports.
1.3.6.1.4.1.14841.1.1.1.5INTEGER {unchanged(1), reset(2)}read-writecurrent
relayChangeNotification
OBJECT-TYPE
This notification is sent to the manager after a line status (or relay) change. It takes three parameters : the slot (relaySlot) and port (relayPort) of the line, and its new status (relayStatus)
1.3.6.1.4.1.14841.1.1.1.6SnmpAdminStringaccessible-for-notifycurrent