MIBs Depot

KYOCERA-Private-MIB

Registered at
1.3.6.1.4.1.1347
Namespace
kyocera
Source file
KYOCERA-Private-MIB
Digest
sha256:2d304ff38a4a6bbaff80f9b570139ea2029cb5839f931f25e9a43cf93de22238

Imports

FromSymbols
HOST-RESOURCES-MIBhrDeviceIndex
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

HOST-RESOURCES-MIB
IANAifType-MIB
IF-MIB
KYOCERA-Private-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
kyocera
OBJECT-IDENTITY
1.3.6.1.4.1.1347
kcPrinter
OBJECT-IDENTITY
1.3.6.1.4.1.1347.43
kcprtGeneral
OBJECT-IDENTITY
1.3.6.1.4.1.1347.43.5
kcprtGeneralTable
OBJECT-TYPE
This table contains the generic parameters that is applied to the KYOCERA network printer.
1.3.6.1.4.1.1347.43.5.1not-accessiblemandatory
kcprtGeneralEntry
OBJECT-TYPE
A list of general entries for KYOCERA printer.
1.3.6.1.4.1.1347.43.5.1.1not-accessiblemandatory
kcprtGeneralModelName
OBJECT-TYPE
The printer's model name.
1.3.6.1.4.1.1347.43.5.1.1.1DisplayString (SIZE(0..32))read-onlymandatory
kcprtOptionDescription
OBJECT-TYPE
The string used for identify the option interface.
1.3.6.1.4.1.1347.43.5.1.1.2DisplayString (SIZE(0..10))read-onlymandatory
kcprtKpdlLevel
OBJECT-TYPE
The level of KPDL. The value (0) means KPDL is not supported or KPDL ROM is missing.
1.3.6.1.4.1.1347.43.5.1.1.3INTEGER (0..2)read-onlymandatory
kcprtSystemUpTime
OBJECT-TYPE
The amount of time since this printer was last powered on. Unit is second.
1.3.6.1.4.1.1347.43.5.1.1.4INTEGER (0..4294967295)read-onlymandatory
kcprtBinNumber
OBJECT-TYPE
The number of paper bins that is implemented within printer itself. This number does not show all of input bin number.
1.3.6.1.4.1.1347.43.5.1.1.5INTEGER (0..255)read-onlymandatory
kcprtCardSlotCapacity
OBJECT-TYPE
The number of IC card slots that this printer actually has. The value (0) means this printer has no IC card slot.
1.3.6.1.4.1.1347.43.5.1.1.6INTEGER (0..255)read-onlymandatory
kcprtRomSlotCapacity
OBJECT-TYPE
The number of option ROM slots. The value (0) means this printer has no option ROM slot.
1.3.6.1.4.1.1347.43.5.1.1.7INTEGER (0..255)read-onlymandatory
kcprtSimmSlotCapacity
OBJECT-TYPE
The number of SIMM slots that this printer actually has.
1.3.6.1.4.1.1347.43.5.1.1.8INTEGER (0..255)read-onlymandatory
kcprtSimmSlotUsed
OBJECT-TYPE
The number of SIMM slots that is currently used for SIMM.
1.3.6.1.4.1.1347.43.5.1.1.9INTEGER (0..255)read-onlymandatory
kcprtOriginalMemorySize
OBJECT-TYPE
The amount of memory that this printer has on its controller board. Note this value does not include any other optional memory. Unit is kilobytes.
1.3.6.1.4.1.1347.43.5.1.1.10INTEGER (0..4294967295)read-onlymandatory
kcprtTotalMemorySize
OBJECT-TYPE
The amount of memory that this printer actually has. Unit is kilobytes.
1.3.6.1.4.1.1347.43.5.1.1.11INTEGER (0..4294967295)read-onlymandatory
kcprtUserMemorySize
OBJECT-TYPE
The amount of memory that is available for user. Unit is kilobyte.
1.3.6.1.4.1.1347.43.5.1.1.12INTEGER (0..4294967295)read-onlymandatory
kcprtVirtualMemory
OBJECT-TYPE
This object shows whether this printer has the virtual memory function.
1.3.6.1.4.1.1347.43.5.1.1.13INTEGER {notSupported(0), support(1)}read-onlymandatory
kcprtPageMemorySize
OBJECT-TYPE
The page memory size corresponding to the FRPO R5 parameter. Because each model of our printer has slightly different value combination, it is recommended to verify the value after writing. Please ask to KYOCERA about the value combination for each printer. For example, our A3 type printer does not have this capability so that The value will be always 512KB(3). The value (-1) means others. Writing (-1) has no meaning.
1.3.6.1.4.1.1347.43.5.1.1.14INTEGER {size-128KB(1), size-256KB(2), size-512KB(3), size-A4orLetter(4), size-Legal(5), size-doubleA4orLetter(6), size-doubleLegal(7)}read-writemandatory
kcprtHostBufferSize
OBJECT-TYPE
The host buffer size in units of ten kilobytes. The value(0) means that the host buffer size is 5 Kbytes.
1.3.6.1.4.1.1347.43.5.1.1.15INTEGER (0..99)read-writemandatory
kcprtHostBuffer1stRate
OBJECT-TYPE
The ratio of the main host buffer size.
1.3.6.1.4.1.1347.43.5.1.1.16INTEGER (0..9)read-writemandatory
kcprtHostBuffer2ndRate
OBJECT-TYPE
The ratio of the 2nd host buffer size.
1.3.6.1.4.1.1347.43.5.1.1.17INTEGER (0..9)read-writemandatory
kcprtHostBuffer3rdRate
OBJECT-TYPE
The ratio of the 3rd host buffer size. Note that this entry will be 'not accessible' if the printer has only two interfaces.
1.3.6.1.4.1.1347.43.5.1.1.18INTEGER (0..9)read-writemandatory
kcprtHostBufferOption
OBJECT-TYPE
In the automatic mode, the first data arriving from the computer go into main buffer (1st buffer). In the fixed mode, each buffer is fixed on the appropriate interface. Refer to User’s manual.
1.3.6.1.4.1.1347.43.5.1.1.19INTEGER {automatic(0), fixed(1)}read-writemandatory
kcprtBufferXoffLevel
OBJECT-TYPE
The printer will pause for receiving data when the ratio of occupied data on the host buffer reaches this threshold level. Note that this value should be larger than kcprtBufferXonLevel. If not, the value is ignored.
1.3.6.1.4.1.1347.43.5.1.1.20INTEGER (0..99)read-writemandatory
kcprtBufferXonLevel
OBJECT-TYPE
The printer will begin to receive data again when the ratio of occupied data on the host buffer becomes lower than this threshould level. Note that value should be less than kcprtBufferXoffLevel. If not, the value is ignored.
1.3.6.1.4.1.1347.43.5.1.1.21INTEGER (0..99)read-writemandatory
kcprtFFTimeout
OBJECT-TYPE
The form-feed time-out timer in units of five seconds. The value (0) means the time-out timer is off.
1.3.6.1.4.1.1347.43.5.1.1.22INTEGER (0..99)read-writemandatory
kcprtSleepTimer
OBJECT-TYPE
The value of sleep timer in units of five minutes. The value (0) means the sleep timer is off.
1.3.6.1.4.1.1347.43.5.1.1.23INTEGER (0..24)read-writemandatory
kcprtWakeupStatusPage
OBJECT-TYPE
If enable, a printer generates the status page each time it comes up.
1.3.6.1.4.1.1347.43.5.1.1.24INTEGER {disable(0), enable(1)}read-writemandatory
kcprtOnlineControl
OBJECT-TYPE
This object controls the on/off line status. Note the writing value does not apply in some situation.
1.3.6.1.4.1.1347.43.5.1.1.25INTEGER {offLine(0), onLine(1)}read-writemandatory
kcprtCopyCount
OBJECT-TYPE
The default copy number.
1.3.6.1.4.1.1347.43.5.1.1.26INTEGER (1..999)read-writemandatory
kcprtCpuTable
OBJECT-TYPE
Information of CPU that is implemented in the printer.
1.3.6.1.4.1.1347.43.5.4not-accessiblemandatory
kcprtCpuEntry
OBJECT-TYPE
A list of CPU information for KYOCERA printer.
1.3.6.1.4.1.1347.43.5.4.1not-accessiblemandatory
kcprtCpuIndex
OBJECT-TYPE
A unique value used by the printer to identify CPU on the printer’s controller.
1.3.6.1.4.1.1347.43.5.4.1.1INTEGERnot-accessiblemandatory
kcprtCpuName
OBJECT-TYPE
The CPU model name, such as ‘68EC040’.
1.3.6.1.4.1.1347.43.5.4.1.2DisplayString (SIZE(0..31))read-onlymandatory
kcprtCpuClock
OBJECT-TYPE
The clock speed of CPU in unit of MHz.
1.3.6.1.4.1.1347.43.5.4.1.3INTEGERread-onlymandatory
kcprtCpuRole
OBJECT-TYPE
The role of this CPU. The value (-1) means others.
1.3.6.1.4.1.1347.43.5.4.1.4INTEGER {engine(0), controller(1)}read-onlymandatory
kcprtFirmwareVersion
OBJECT-TYPE
The version string for the firmware of this CPU.
1.3.6.1.4.1.1347.43.5.4.1.5DisplayString (SIZE(0..31))read-onlymandatory
kcprtFirmwareUpdata
OBJECT-TYPE
Shows whether this firmware can be updated on the controller.
1.3.6.1.4.1.1347.43.5.4.1.6INTEGER {enabled(3), disabled(4)}read-onlymandatory
kcprtOutput
OBJECT-IDENTITY
1.3.6.1.4.1.1347.43.9
kcprtOutputTable
OBJECT-TYPE
This table contains the basic part of the output unit. The main purpose is to control SO-6.
1.3.6.1.4.1.1347.43.9.1not-accessiblemandatory
kcprtOutputEntry
OBJECT-TYPE
A list of information for the output unit, especially for the SO-6.
1.3.6.1.4.1.1347.43.9.1.1not-accessiblemandatory
kcprtOutputIndex
OBJECT-TYPE
The value of the prtOutputIndex of this printer that this entry is associated with.
1.3.6.1.4.1.1347.43.9.1.1.1INTEGERnot-accessiblemandatory
kcprtOutputMode
OBJECT-TYPE
The operation mode of the sorter. If this device does not support the sorter function, the reading value is (-1) and all writing are ignored. Also, writing value (-1) does not take effect.
1.3.6.1.4.1.1347.43.9.1.1.2INTEGER {sorter(0), collator(1), stacker(2), mailbox(3)}read-writemandatory
kcprtOutputMultiMode
OBJECT-TYPE
In the multiple mode, the sorter can simultaneously be used by different computers. Each computer may assign its own output trays. This value determines how the tray is selected. The value (-1) means others or 'not supported'.
1.3.6.1.4.1.1347.43.9.1.1.3INTEGER {off(0), id-specific(1), if-specific(2)}read-writemandatory
kcprtOutputGroupNumber
OBJECT-TYPE
This entry shows how many groups are existing on the output device.
1.3.6.1.4.1.1347.43.9.1.1.4INTEGERread-onlymandatory
kcprtOutputDefaultGroup
OBJECT-TYPE
The value of the kcprtTrayGroupIndex corresponding to the current output tray group in a sorter. This value has no meaning if this output unit is not a soter. The value (0) means that the multiple mode is disabled and all of trays will be able to use. Writing value (0) indicates a selection of bulkTray . Writing is only allowed when the multiple mode is enabled.
1.3.6.1.4.1.1347.43.9.1.1.5INTEGERread-writemandatory
kcprtOutputBulkStatus
OBJECT-TYPE
This entry shows current status of the bulk tray. Since the bulk tray of SO-6 has only a full sensor, this entry has only two states. In future, the state will be added.
1.3.6.1.4.1.1347.43.9.1.1.6INTEGER {notFull(0), full(1)}read-onlymandatory
kcprtOutputTrayMaxCapacity
OBJECT-TYPE
This entry shows how many pages the tray on this output device can hold. Unit is sheet.
1.3.6.1.4.1.1347.43.9.1.1.7INTEGERread-onlymandatory
kcprtTrayGroupTable
OBJECT-TYPE
The concept of Group is for the multiple computer environment. These contents take effect when kcprtOutputMultiMode is enable. For further information, refer to the sorter manual. Note in case of off (0), the access to this content is ineffective.
1.3.6.1.4.1.1347.43.9.2not-accessiblemandatory
kcprtTrayGroupEntry
OBJECT-TYPE
A list of information about the tray group on the multiple tray device.
1.3.6.1.4.1.1347.43.9.2.1not-accessiblemandatory
kcprtTrayGroupIndex
OBJECT-TYPE
The unique value used by the printer to identify each tray groups. Note that this value will be changed while the printer power cycles if Prescribe ASTK command is issued.
1.3.6.1.4.1.1347.43.9.2.1.1INTEGERnot-accessiblemandatory
kcprtTrayGroupBeginIndex
OBJECT-TYPE
The value of the kcprtOutputTrayIndex corresponding to the tray that is assigned as the begining of this group.
1.3.6.1.4.1.1347.43.9.2.1.2INTEGERread-onlymandatory
kcprtTrayGroupEndIndex
OBJECT-TYPE
The value of the kcprtOutputTrayIndex corresponding to the tray that is assigned as the end of this group. This index is automatically assigned by the printer when the group is created. Please refer to thePrescribe manual for detailed information.
1.3.6.1.4.1.1347.43.9.2.1.3INTEGERread-onlymandatory
kcprtOutputTrayTable
OBJECT-TYPE
Note in case of off (0), the access to this content is ineffective.
1.3.6.1.4.1.1347.43.9.3not-accessiblemandatory
kcprtOutputTrayEntry
OBJECT-TYPE
A list of information about the individual tray.
1.3.6.1.4.1.1347.43.9.3.1not-accessiblemandatory
kcprtOutputTrayIndex
OBJECT-TYPE
The unique value used by a printer to identify each trays. Values are expected to remain stable across successive printer power cycle. This contents has no meaning except for a sorter device.
1.3.6.1.4.1.1347.43.9.3.1.1INTEGERnot-accessiblemandatory
kcprtOutputTrayOrder
OBJECT-TYPE
The output order for trays. The beginning number is (1) and the last number should be equal to the maximum tray number. When the multiple mode is available, the order in the appropriate group is determined by this entry. The number should be unique and continuous in one group or the whole if the group function is disabled. The value (0) means the order has not been determined. In case all of the trays are not determined, the sorter will operate in default settings. About default settings, refer to the sorter’s manual. Currently this entry is read-only.
1.3.6.1.4.1.1347.43.9.3.1.2INTEGERread-onlymandatory
kcprtOutputTrayGroup
OBJECT-TYPE
The value of kcprtTrayGroupIndex corresponding to the group that this tray is assigned to. The value (0) means this tray is not assigned to a group or the multiple mode is disable.
1.3.6.1.4.1.1347.43.9.3.1.3INTEGERread-onlymandatory
kcprtOutputTrayCount
OBJECT-TYPE
The count of page that the tray may be holding. Since the tray cannot count the page that it has currently, the value is not always same as the actual page counts. If all of paper is removed, this value will be 0. In SO-6, there is no full sensor. So, if the application needs to know whether the tray is full or not, the application should compare this value with OutputTrayMaxCapacity. In some case, the printer is turned on with remaining some pages on the tray for example, this value will be same as MaxCapacity to inform that paper is remaining and demand to remove the page.
1.3.6.1.4.1.1347.43.9.3.1.4INTEGERread-onlymandatory
kcprtMarker
OBJECT-IDENTITY
1.3.6.1.4.1.1347.43.10
kcprtMarkerTable
OBJECT-TYPE
This table contains some useful entries to control the marker specific function.
1.3.6.1.4.1.1347.43.10.1not-accessiblemandatory
kcprtMarkerEntry
OBJECT-TYPE
A list of entries that corresponds each function of the marker.
1.3.6.1.4.1.1347.43.10.1.1not-accessiblemandatory
kcprtMarkerIndex
OBJECT-TYPE
The value of the prtMarkerIndex of the printer devices with which it is associated.
1.3.6.1.4.1.1347.43.10.1.1.1INTEGERnot-accessiblemandatory
kcprtMarkerKirLevel
OBJECT-TYPE
The value that shows current KIR level. The value (0) means off or not support (0).
1.3.6.1.4.1.1347.43.10.1.1.2INTEGER {offOrNotSupport(0), light(1), medium(2), dark(3)}read-writemandatory
kcprtMarkerEcoprintLevel
OBJECT-TYPE
The value that shows current Ecoprint level. The value (0) means off or not support.
1.3.6.1.4.1.1347.43.10.1.1.3INTEGER {offOrNotSupport(0), light(1), medium(2), dark(3)}read-writemandatory
kcprtMarkerAddressabilityFeedDirDeclared
OBJECT-TYPE
This object provides the value of the declared addressability, in the feed direction, of this marker. This addressability is measured in prtMarkerAddressabilityUnit.
1.3.6.1.4.1.1347.43.10.1.1.4INTEGERread-writemandatory
kcprtMarkerAddressabilityXFeedDirDeclared
OBJECT-TYPE
This object provides the value of declared dimension, in the cross feed direction, of this marker device. This addressability is measured in prtMarkerAddressabilityUnit.
1.3.6.1.4.1.1347.43.10.1.1.5INTEGERread-writemandatory
kcprtMarkerAddressablilityFeedDirChosen
OBJECT-TYPE
The value of the addressability, in the feed direction, chosen by the printer. If the printer supports the declared addressability, this addressability is the same as the declared addressability. If not, this addressability is set to the closest addressability that the printer supports when the declared dimension is set.
1.3.6.1.4.1.1347.43.10.1.1.6INTEGERread-onlymandatory
kcprtMarkerAddressablilityXFeedDirChosen
OBJECT-TYPE
The value of the addressability, in the cross feed direction, chosen by the printer. If the printer supports the declared addressability, this addressability is the same as the declared addressability. If not, this addressability is set to the closest addressability that the printer supports when the declared dimension is set.
1.3.6.1.4.1.1347.43.10.1.1.7INTEGERread-onlymandatory
kcprtChannel
OBJECT-IDENTITY
1.3.6.1.4.1.1347.43.14
kcprtChannelTable
OBJECT-TYPE
This table control's HEX dump function.
1.3.6.1.4.1.1347.43.14.1not-accessiblemandatory
kcprtChannelEntry
OBJECT-TYPE
1.3.6.1.4.1.1347.43.14.1.1not-accessiblemandatory
kcprtChannelIndex
OBJECT-TYPE
The value of the prtChannelIndex of the printer device that this prtChannelEntry is associated with.
1.3.6.1.4.1.1347.43.14.1.1.1INTEGERnot-accessiblemandatory
kcprtChannelFunction
OBJECT-TYPE
The current state of the function of this channel. KYOCERA printer can set the hex dump mode to interface (channel). Writing affects all interface(channel).This setting is only valid for one job. After processing the job, this entry automatically returns ‘through(0)’.
1.3.6.1.4.1.1347.43.14.1.1.2INTEGER {through(0), hexDump(1)}read-writemandatory
kcprtMemoryResource
OBJECT-IDENTITY
1.3.6.1.4.1.1347.43.20
kcprtMemoryDeviceTable
OBJECT-TYPE
This table contains information for each memory device, such as the IC-Card.
1.3.6.1.4.1.1347.43.20.1not-accessiblemandatory
kcprtMemoryDeviceEntry
OBJECT-TYPE
A list of entries that are corresponding to the each function of the memory device.
1.3.6.1.4.1.1347.43.20.1.1not-accessiblemandatory
kcprtMemoryDeviceIndex
OBJECT-TYPE
A unique value that is corresponding to each memory device, such as IC-Card. The value assignment will change if the IC-Card is removed or inserted.
1.3.6.1.4.1.1347.43.20.1.1.1INTEGERnot-accessiblemandatory
kcprtMemoryDeviceLocation
OBJECT-TYPE
The value shows the location of this memory device. Note that if the location is download area, only the resource that has been assigned to the current interface can be managed. To see other resources, the management application have to change the current interface.
1.3.6.1.4.1.1347.43.20.1.1.2INTEGER {icCardSlot-A(0), icCardslot-B(1), optionROMsocket(2), residentFont(3), downloadArea(4), others(255)}read-onlymandatory
kcprtMemoryDeviceType
OBJECT-TYPE
The value shows the type of this memory device.
1.3.6.1.4.1.1347.43.20.1.1.3INTEGER {rom(0), flash(1), sram(2), dram(3), others(255)}read-onlymandatory
kcprtMemoryDeviceTotalSize
OBJECT-TYPE
The maximum space of the memory device. Unit is bytes.
1.3.6.1.4.1.1347.43.20.1.1.4INTEGERread-onlymandatory
kcprtMemoryDeviceUsedSize
OBJECT-TYPE
The amount of occupied space on the device. Unit is bytes. If the device cannot detect the amount, the value is (-1).
1.3.6.1.4.1.1347.43.20.1.1.5INTEGERread-onlymandatory
kcprtMemoryDeviceStatus
OBJECT-TYPE
This value shows current status of this device. ‘not accessible’ means that the printer recognized the device but the access is impossible. ‘battery low’ is for a kind of battery backuped device, such as IC-card.
1.3.6.1.4.1.1347.43.20.1.1.6INTEGER {readyReadWrite(0), readyReadOnly(1), notAccessible(2), lowBattery(4)}read-onlymandatory
kcprtPartitionTable
OBJECT-TYPE
This table contains partition information for each device.
1.3.6.1.4.1.1347.43.20.2not-accessiblemandatory
kcprtPartitionEntry
OBJECT-TYPE
A list of entries that is corresponding to the each information about the partition.
1.3.6.1.4.1.1347.43.20.2.1not-accessiblemandatory
kcprtPartitionIndex
OBJECT-TYPE
A unique value corresponding to the each partition on the printer's memory device. This assigment will change in some cases.
1.3.6.1.4.1.1347.43.20.2.1.1INTEGERnot-accessiblemandatory
kcprtPartitionSize
OBJECT-TYPE
This value shows the size of this partition. Unit is byte.
1.3.6.1.4.1.1347.43.20.2.1.2INTEGERread-onlymandatory
kcprtPartitionLocation
OBJECT-TYPE
This value of kcprtMemoryDeviceIndex corresponding to the device on which this partition exists. If the device is unknown, this value is (-1).
1.3.6.1.4.1.1347.43.20.2.1.3INTEGERread-onlymandatory
kcprtPartitionResourceType
OBJECT-TYPE
The type of the resource that is using this partition.
1.3.6.1.4.1.1347.43.20.2.1.4INTEGER {void(0), macro(3), hostData(4), programData(5), messageData(6), fontData(7)}read-onlymandatory
kcprtPartitionName
OBJECT-TYPE
The name that is assigned to this partition.
1.3.6.1.4.1.1347.43.20.2.1.5DisplayString (SIZE(1..15))read-onlymandatory
kcprtPartitionLoad
OBJECT-TYPE
This value shows whether this partition has been read by the printer. basically, the resource should be read by the printer to make it available.
1.3.6.1.4.1.1347.43.20.2.1.6INTEGER {notLoaded(0), loaded(1)}read-onlymandatory
kcprtMacroDataTable
OBJECT-TYPE
This table contains information about MACRO resource.
1.3.6.1.4.1.1347.43.20.3not-accessiblemandatory
kcprtMacroDataEntry
OBJECT-TYPE
1.3.6.1.4.1.1347.43.20.3.1not-accessiblemandatory
kcprtMacroDataIndex
OBJECT-TYPE
1.3.6.1.4.1.1347.43.20.3.1.1INTEGERnot-accessiblemandatory
kcprtMacroDataName
OBJECT-TYPE
This value will be effective if the macro is described in Prescribe. Otherwise, this value will be NULL.
1.3.6.1.4.1.1347.43.20.3.1.2DisplayString (SIZE(1..4))read-onlymandatory
kcprtMacroDataID
OBJECT-TYPE
This value will be effective if the macro is described in PCL. Otherwise, the value will be unknown(-1).
1.3.6.1.4.1.1347.43.20.3.1.3INTEGERread-onlymandatory
kcprtMacroDataType
OBJECT-TYPE
This value is corresponding to the PDL that is used for decribing this macro.
1.3.6.1.4.1.1347.43.20.3.1.4INTEGER {prescribe(1), pcl(2), others(255)}read-onlymandatory
kcprtMacroDataAutoLoad
OBJECT-TYPE
This value shows the state of the form overlay function that is controled by AMCR command. Only one macro can be set as ‘on’, so at most one entry will have ‘on’ value.
1.3.6.1.4.1.1347.43.20.3.1.5INTEGER {off(0), onWithInitialize(1), onWithoutInitialize(2)}read-onlymandatory
kcprtMacroDataLocation
OBJECT-TYPE
The value of kcprtMemoryDeviceIndex correspinding to the device that this macro is currently stored. unknown is (-1).
1.3.6.1.4.1.1347.43.20.3.1.6INTEGERread-onlymandatory
kcprtMacroDataAttribute
OBJECT-TYPE
‘not registered’ means this resource is existing on the device but it is not available for the printer. For example, macro on the IC card that is inserted into the printer after turning on will be ‘not registered’. To turn it into ‘registered’, user must select them from the front panel menu.
1.3.6.1.4.1.1347.43.20.3.1.7INTEGER {notRegistered(0), registered(1)}read-onlymandatory
kcprtHostDataTable
OBJECT-TYPE
This table contains information about the host data. Note that 'Host data' does not mean the job itself.
1.3.6.1.4.1.1347.43.20.4not-accessiblemandatory
kcprtHostDataEntry
OBJECT-TYPE
A list of entries that are corresponding each information of the host data.
1.3.6.1.4.1.1347.43.20.4.1not-accessiblemandatory
kcprtHostDataIndex
OBJECT-TYPE
A unique value corresponding to each information of the host data. The assigment will change in some case.
1.3.6.1.4.1.1347.43.20.4.1.1INTEGERnot-accessiblemandatory
kcprtHostDataName
OBJECT-TYPE
The name that is used for descriminating each host data.
1.3.6.1.4.1.1347.43.20.4.1.2DisplayString (SIZE(1..15))read-onlymandatory
kcprtHostDataLocation
OBJECT-TYPE
The value of kcprtMemoryDeviceIndex that is corresponding to the device in which this host data is stored. If the device is unknown, the value is -1.
1.3.6.1.4.1.1347.43.20.4.1.3INTEGERread-onlymandatory
kcprtHostDataAttribute
OBJECT-TYPE
Basically, the value is always ‘registered’.
1.3.6.1.4.1.1347.43.20.4.1.4INTEGER {notRegistered(0), registered(1)}read-onlymandatory
kcprtProgramDataTable
OBJECT-TYPE
This table contains information about the program data. The program data is a kind of emulation and a Prescribe command, not a macro.
1.3.6.1.4.1.1347.43.20.5not-accessiblemandatory
kcprtProgramDataEntry
OBJECT-TYPE
A list of entries that are corresponding to each information of the program data.
1.3.6.1.4.1.1347.43.20.5.1not-accessiblemandatory
kcprtProgramDataIndex
OBJECT-TYPE
A unique value corresponding to each program data. This assigment may change in some case.
1.3.6.1.4.1.1347.43.20.5.1.1INTEGERnot-accessiblemandatory
kcprtProgramDataName
OBJECT-TYPE
1.3.6.1.4.1.1347.43.20.5.1.2DisplayString (SIZE(1..15))read-onlymandatory
kcprtProgramDataType
OBJECT-TYPE
1.3.6.1.4.1.1347.43.20.5.1.3INTEGER {emulation(0), prescribe(1), others(255)}read-onlymandatory
kcprtProgramDataLocation
OBJECT-TYPE
The value of kcprtMemoryDeviceIndex corresponding to the device in which this program data is stored. If the device is unknown, the value is (-1).
1.3.6.1.4.1.1347.43.20.5.1.4INTEGERread-onlymandatory
kcprtProgramDataAttribute
OBJECT-TYPE
‘running’ means the program is running.
1.3.6.1.4.1.1347.43.20.5.1.5INTEGER {notRegistered(0), registered(1), running(2)}read-onlymandatory
kcprtMessageDataTable
OBJECT-TYPE
This is a bunch of message that is handled as one of the flont panel language by the printer.
1.3.6.1.4.1.1347.43.20.6not-accessiblemandatory
kcprtMessageDataEntry
OBJECT-TYPE
A list of entries that are corresponding to each information of the message data.
1.3.6.1.4.1.1347.43.20.6.1not-accessiblemandatory
kcprtMessageDataIndex
OBJECT-TYPE
The index vaule that is assigned to each front panel language.
1.3.6.1.4.1.1347.43.20.6.1.1INTEGERnot-accessiblemandatory
kcprtMessageDataName
OBJECT-TYPE
The name of the message data block.
1.3.6.1.4.1.1347.43.20.6.1.2DisplayString (SIZE(1..15))read-onlymandatory
kcprtMessageDataLocation
OBJECT-TYPE
The value of kcprtMemoryDeviceIndex corresponding to the device in which this message data is stored. If the device is unknown, the value is -1.
1.3.6.1.4.1.1347.43.20.6.1.3INTEGERread-onlymandatory
kcprtMessageDataAttribute
OBJECT-TYPE
Always ‘registered’ in the current products.
1.3.6.1.4.1.1347.43.20.6.1.4INTEGER {notRegistered(0), registered(1)}read-onlymandatory
kcprtFontDataTable
OBJECT-TYPE
This table contains font information.
1.3.6.1.4.1.1347.43.20.7not-accessiblemandatory
kcprtFontDataEntry
OBJECT-TYPE
A list of entries that are corresponding each information of the font.
1.3.6.1.4.1.1347.43.20.7.1not-accessiblemandatory
kcprtFontDataIndex
OBJECT-TYPE
A unique value corresponding to each font data. The assignment may change in some case.
1.3.6.1.4.1.1347.43.20.7.1.1INTEGERnot-accessiblemandatory
kcprtTypeFaceName
OBJECT-TYPE
The value will be NULL if no name has been assigned.
1.3.6.1.4.1.1347.43.20.7.1.2DisplayString (SIZE(0..31))read-onlymandatory
kcprtFontID
OBJECT-TYPE
This value will be -1 if no ID has been assigned.
1.3.6.1.4.1.1347.43.20.7.1.3INTEGERread-onlymandatory
kcprtFontType
OBJECT-TYPE
1.3.6.1.4.1.1347.43.20.7.1.4INTEGER {bitmap(0), scalable(1), others(255)}read-onlymandatory
kcprtFontLocation
OBJECT-TYPE
The value of kcprtMemoryDeviceIndex corresponding to the device on which this font is stored. If it is unknown, the value is -1.
1.3.6.1.4.1.1347.43.20.7.1.5INTEGERread-onlymandatory
kcprtFontAttribute
OBJECT-TYPE
In the current printer, this value is always ‘registered’.
1.3.6.1.4.1.1347.43.20.7.1.6INTEGER {notRegistered(0), registered(1)}read-onlymandatory