Juniper-TSM-MIB
- Registered at
- 1.3.6.1.4.1.4874.2.2.72
- Last updated
- 2005-05-23 14:37
- Organization
- Juniper Networks, Inc.
- Revisions
- 2005-05-23 14:37, 2005-04-27 22:57, 2003-10-23 20:45
- Namespace
- juniper
- Source file
Juniper-TSM-MIB- Digest
sha256:457b12f5cc7f6b4e0627e3b3f9b7e80cc1680b2518d8ba2069efc07daff10241
Description
The Tunnel Server Management (TSM) MIB for the Juniper Networks enterprise.
Contact
Juniper Networks, Inc. Postal: 10 Technology Park Drive Westford, MA 01886-3146 USA Tel: +1 978 589 5800 Email: mib@Juniper.net
Imports
| From | Symbols |
|---|---|
| Juniper-MIBs | juniMibs |
| Juniper-UNI-IF-MIB | JuniIfType |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Gauge32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB IF-MIB Juniper-MIBs Juniper-TSM-MIB Juniper-UNI-IF-MIB Juniper-UNI-SMI SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| JuniTsmLocationType TEXTUAL-CONVENTION Describes the platform-dependent interpretation of a JuniTsmLocationValue object: unknown Unspecified/unknown slotPort Two octets in length; first octet is 'slot', second octet is 'port' slotAdapterPort Three octets in length; first octet is 'slot', second octet is 'adapter', third octet is 'port' adapterPort Two octets in length; first octet is 'adapter', second octet is 'port' | current | |||
| JuniTsmLocationValue TEXTUAL-CONVENTION The value of a platform-dependent interface location, represented as an OCTET STRING. A corresponding JuniTsmLocationType object will identify the mapping of octets to location elements, e.g. 'slot.port'. Note, when the value of an object having this syntax is encoded as a MIB table INDEX, the rules for encoding a variable-length OCTET STRING are observed. | current |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| juniTsmObjects OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.72.1 | |||
| juniTsmData OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.72.1.1 | |||
| juniTsmLocationType OBJECT-TYPE Describes the interpretation of JuniTsmLocationValue object values into platform-dependent interface location components, e.g., 'slot.port'. | 1.3.6.1.4.1.4874.2.2.72.1.1.1 | JuniTsmLocationType | read-only | current |
| juniTsmPortTable OBJECT-TYPE This table allows dynamic server ports to be configured and also provides information about static ports available in the system. This table represents all ports known to the system. The presence of a port in this table does not guarantee that a card with this port is present in the chassis. | 1.3.6.1.4.1.4874.2.2.72.1.1.2 | not-accessible | current | |
| juniTsmPortEntry OBJECT-TYPE Configuration data. | 1.3.6.1.4.1.4874.2.2.72.1.1.2.1 | not-accessible | current | |
| juniTsmPortLocation OBJECT-TYPE The value of a port location. | 1.3.6.1.4.1.4874.2.2.72.1.1.2.1.1 | JuniTsmLocationValue | not-accessible | current |
| juniTsmPortType OBJECT-TYPE The port type: generalPurposeStatic - statically configured (always on) port, generalPurposeDynamic - dynamic port, which could be both configured with different maximum number of interfaces and unconfigured, securityStatic - static port equipped with encryption (IPSEC) hardware. securityDynamic - dynamic port with encryption (IPSEC) hardware, which could be both configured with different maximum number of interfaces and unconfigured. | 1.3.6.1.4.1.4874.2.2.72.1.1.2.1.2 | INTEGER {generalPurposeStatic(1), generalPurposeDynamic(2), securityStatic(3), securityDynamic(4)} | read-only | current |
| juniTsmPortHwPresent OBJECT-TYPE The port hardware is inserted. | 1.3.6.1.4.1.4874.2.2.72.1.1.2.1.3 | TruthValue | read-only | current |
| juniTsmPortAvailableInterfaces OBJECT-TYPE Maximum number of interfaces available on the port. | 1.3.6.1.4.1.4874.2.2.72.1.1.2.1.4 | Integer32 (1..16000) | read-only | current |
| juniTsmPortProvisionedInterfaces OBJECT-TYPE Number of interfaces provisioned on the port. '-1' means all available interfaces. If port is static this value cannot be changed. If the number of provisioned interfaces is decreased it may require a lengthy 'draining' process to bring number of allocated interfaces into compliance. | 1.3.6.1.4.1.4874.2.2.72.1.1.2.1.5 | Integer32 (-1..16000) | read-write | current |
| juniTsmAppRegistryTable OBJECT-TYPE This table describes currently registered applications. | 1.3.6.1.4.1.4874.2.2.72.1.1.3 | not-accessible | current | |
| juniTsmAppRegistryEntry OBJECT-TYPE Application data. | 1.3.6.1.4.1.4874.2.2.72.1.1.3.1 | not-accessible | current | |
| juniTsmAppRegistryIndex OBJECT-TYPE A small integer identifying registered application. Once an application is registered, this integer will be associated with the application until the next reboot. | 1.3.6.1.4.1.4874.2.2.72.1.1.3.1.1 | Integer32 (1..2147483647) | not-accessible | current |
| juniTsmAppRegistryIfType OBJECT-TYPE Interface type associated with the application. | 1.3.6.1.4.1.4874.2.2.72.1.1.3.1.2 | JuniIfType | read-only | current |
| juniTsmAppRegistryName OBJECT-TYPE The name of the application used by the system. | 1.3.6.1.4.1.4874.2.2.72.1.1.3.1.3 | DisplayString | read-only | current |
| juniTsmAppRegistryInterfaceLimit OBJECT-TYPE The maximum number of interfaces per port this application supports. (The number of interfaces could be further limited by the port capacity.) | 1.3.6.1.4.1.4874.2.2.72.1.1.3.1.4 | Integer32 (1..2147483647) | read-only | current |
| juniTsmApplicationTable OBJECT-TYPE The entries in this table describe application load on tunnel servers. This table includes only applications which are actually being used. | 1.3.6.1.4.1.4874.2.2.72.1.1.4 | not-accessible | current | |
| juniTsmApplicationEntry OBJECT-TYPE Configuration data. | 1.3.6.1.4.1.4874.2.2.72.1.1.4.1 | not-accessible | current | |
| juniTsmApplicationMaxInterfaces OBJECT-TYPE Maximum number of interfaces available on the port for the application. Applications allocate interfaces from a common pool, so this is not the only limit of application level interfaces. This value could be greater than juniTsmPortProvisionedInterfaces when the port is draining interfaces. | 1.3.6.1.4.1.4874.2.2.72.1.1.4.1.1 | Integer32 (1..2147483647) | read-only | current |
| juniTsmApplicationActiveInterfaces OBJECT-TYPE Number of application interfaces in use on the port. This value could be greater than juniTsmPortProvisionedInterfaces when the port is draining interfaces. | 1.3.6.1.4.1.4874.2.2.72.1.1.4.1.2 | Gauge32 | read-only | current |
| juniTsmMIBConformance OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.72.4 | |||
| juniTsmMIBCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.72.4.1 | |||
| juniTsmMIBGroups OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.72.4.2 |
Conformance
| Name | OID | Status |
|---|---|---|
| juniTsmCompliance MODULE-COMPLIANCE The compliance statement for TSM mib. | 1.3.6.1.4.1.4874.2.2.72.4.1.1 | current |
| juniTsmGroup OBJECT-GROUP A collection of objects providing management of TSM functionality in a Juniper product. | 1.3.6.1.4.1.4874.2.2.72.4.2.1 | current |