Juniper-ES2-Registry
- Registered at
- 1.3.6.1.4.1.4874.4.2.3
- Last updated
- 2008-05-08 11:48
- Organization
- Juniper Networks, Inc.
- Revisions
- 2008-05-08 11:48, 2006-12-18 21:06, 2006-11-24 09:13, 2006-01-06 18:06, 2005-09-15 13:46, 2005-08-19 11:58, 2005-07-29 18:26, 2004-12-23 11:58, 2004-12-06 10:21, 2004-05-19 17:42, 2003-08-18 20:27
- Namespace
- juniper
- Source file
Juniper-ES2-Registry- Digest
sha256:9e20b2fedf3e35b79b36a0346caa9da5f2fb53d337816885ed0328ad5805784e
Description
Juniper second generation E-series product family system-specific object identification values. This module defines AutonomousType (OID) values for all the physical entity types (entPhysicalVendorType). This module will be updated whenever a new type of module or other hardware becomes available in second generation E-series systems.
Contact
Juniper Networks, Inc. Postal: 10 Technology Park Drive Westford, MA 01886-3146 USA Tel: +1 978 589 5800 Email: mib@Juniper.net
Imports
| From | Symbols |
|---|---|
| Juniper-Registry | juniAdmin |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
Juniper-ES2-Registry Juniper-Registry Juniper-UNI-SMI SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| juniES2EntPhysicalType OBJECT-IDENTITY | 1.3.6.1.4.1.4874.4.2.3.1 | |||
| es2Chassis OBJECT-IDENTITY The vendor type ID for a second generation E-series chassis. This identifies an 'overall' physical entity for any second generation E-series system. | 1.3.6.1.4.1.4874.4.2.3.1.1 | current | ||
| e320BaseChassis OBJECT-IDENTITY E320 base chassis with 12 slots for line modules - includes chassis, midplane, DC PDU, and fan tray. The E320 system uses a carrier-class design with a passive midplane, active front-insert line modules(LM) and rear-insert input/output adapters(IOA). | 1.3.6.1.4.1.4874.4.2.3.1.1.1 | current | ||
| e120BaseChassis OBJECT-IDENTITY E120 base chassis with 6 slots for line modules - includes chassis, midplane, DC PDU, and fan tray. The E120 system uses a carrier-class design with a passive midplane, active front-insert line modules(LM) and rear-insert input/output adapters(IOA). | 1.3.6.1.4.1.4874.4.2.3.1.1.2 | current | ||
| es2FanAssembly OBJECT-IDENTITY The vendor type ID for a second generation E-series fan assembly. | 1.3.6.1.4.1.4874.4.2.3.1.2 | current | ||
| e320PrimaryFanTray OBJECT-IDENTITY E320 fan tray with 8 fans. | 1.3.6.1.4.1.4874.4.2.3.1.2.1 | current | ||
| e320AuxiliaryFanTray OBJECT-IDENTITY E320 fan tray with 8 fans. | 1.3.6.1.4.1.4874.4.2.3.1.2.2 | current | ||
| e120PrimaryFanTray OBJECT-IDENTITY E120 fan tray with 9 fans. | 1.3.6.1.4.1.4874.4.2.3.1.2.3 | current | ||
| es2PowerInput OBJECT-IDENTITY The vendor type ID for a second generation E-series power distribution module. | 1.3.6.1.4.1.4874.4.2.3.1.3 | current | ||
| e320DcPowerDistributionUnit OBJECT-IDENTITY E320 DC power distribution unit (PDU). | 1.3.6.1.4.1.4874.4.2.3.1.3.1 | current | ||
| es2Midplane OBJECT-IDENTITY The vendor type ID for a second generation E-series midplane. | 1.3.6.1.4.1.4874.4.2.3.1.4 | current | ||
| e320Midplane OBJECT-IDENTITY E320 chassis midplane. | 1.3.6.1.4.1.4874.4.2.3.1.4.1 | current | ||
| e120Midplane OBJECT-IDENTITY E120 chassis midplane. | 1.3.6.1.4.1.4874.4.2.3.1.4.2 | current | ||
| es2SrpModule OBJECT-IDENTITY The vendor type ID for a second generation E-series system controller/ switch fabric module. | 1.3.6.1.4.1.4874.4.2.3.1.5 | current | ||
| e320Srp100 OBJECT-IDENTITY E320 100Gb SRP - The Switch Route Processor (SRP) is responsible for running the routing protocols as well as overall system control. The SRP also contains a switch fabric slice that is responsible for packet forwarding. | 1.3.6.1.4.1.4874.4.2.3.1.5.1 | current | ||
| e320Srp320 OBJECT-IDENTITY E320 320Gb SRP - The Switch Route Processor (SRP) is responsible for running the routing protocols as well as overall system control. The SRP also contains a switch fabric slice that is responsible for packet forwarding. | 1.3.6.1.4.1.4874.4.2.3.1.5.2 | current | ||
| e120Srp120 OBJECT-IDENTITY E120 120Gb SRP - The Switch Route Processor (SRP) is responsible for running the routing protocols as well as overall system control. The SRP also contains a switch fabric slice that is responsible for packet forwarding. | 1.3.6.1.4.1.4874.4.2.3.1.5.3 | current | ||
| es2SwitchFabricModule OBJECT-IDENTITY The vendor type ID for a second generation E-series switch fabric module. | 1.3.6.1.4.1.4874.4.2.3.1.6 | current | ||
| e320Sfm100 OBJECT-IDENTITY E320 100Gb switch fabric module. The SFM functions include buffer management, queuing, scheduling and packet processing. | 1.3.6.1.4.1.4874.4.2.3.1.6.1 | current | ||
| e320Sfm320 OBJECT-IDENTITY E320 320Gb switch fabric module. The SFM functions include buffer management, queuing, scheduling and packet processing. | 1.3.6.1.4.1.4874.4.2.3.1.6.2 | current | ||
| e120Sfm120 OBJECT-IDENTITY E120 120Gb switch fabric module. The SFM functions include buffer management, queuing, scheduling and packet processing. | 1.3.6.1.4.1.4874.4.2.3.1.6.3 | current | ||
| es2SrpIoa OBJECT-IDENTITY The vendor type ID for the system controller I/O adapter for a second generation E-series system. | 1.3.6.1.4.1.4874.4.2.3.1.7 | current | ||
| e320SrpIoa OBJECT-IDENTITY E320 SRP IOA. This card provides clocking functions as well as management and alarm interfaces. | 1.3.6.1.4.1.4874.4.2.3.1.7.1 | current | ||
| es2ForwardingModule OBJECT-IDENTITY The vendor type ID for a second generation E-series forwarding module. | 1.3.6.1.4.1.4874.4.2.3.1.8 | current | ||
| es2Lm4 OBJECT-IDENTITY E320 4Gb (series 1) line module. This Line Module supports both uplink and customer facing IOAs and is responsible for processing data traffic. | 1.3.6.1.4.1.4874.4.2.3.1.8.1 | current | ||
| es2Lm10Uplink OBJECT-IDENTITY E320 10Gb (series 2) uplink line module. This Line Module is primarily focused on uplink IOAs and is responsible for processing data traffic. | 1.3.6.1.4.1.4874.4.2.3.1.8.2 | current | ||
| es2Lm10 OBJECT-IDENTITY E320 10Gb (series 3) line module. This Line Module supports both uplink and customer facing IOAs and is responsible for processing data traffic. | 1.3.6.1.4.1.4874.4.2.3.1.8.3 | current | ||
| es2Lm10s OBJECT-IDENTITY E320 10Gb (series 4) line module. This Line Module supports both uplink and customer facing IOAs and is responsible for processing data traffic. | 1.3.6.1.4.1.4874.4.2.3.1.8.4 | current | ||
| es2ForwardingIoa OBJECT-IDENTITY The vendor type ID for a second generation E-series I/O adapter for a forwarding module. | 1.3.6.1.4.1.4874.4.2.3.1.9 | current | ||
| es2Ge4S1Ioa OBJECT-IDENTITY E320 GE-4 IOA. This is a series 1, half-height, single wide IOA with 4 physical interfaces that require pluggable GE interfaces. This IOA uses the full capacity of a Series 1 line module. | 1.3.6.1.4.1.4874.4.2.3.1.9.1 | current | ||
| es2Oc48Stm16PosS1Ioa OBJECT-IDENTITY E320 OC48/STM16 POS IOA. This is a series 1, half-height, single wide IOA with 1 physical interface that requires a pluggable OC48/STM16 interface. | 1.3.6.1.4.1.4874.4.2.3.1.9.2 | current | ||
| es2ServiceS1Ioa OBJECT-IDENTITY E320 service IOA. This is a series 1, full-height, single wide IOA and does not support any physical interfaces. | 1.3.6.1.4.1.4874.4.2.3.1.9.3 | current | ||
| es2Oc3Stm1x8AtmS1Ioa OBJECT-IDENTITY E320 OC3/STM1-8 ATM IOA. This is a series 1, half-height, single wide IOA that supports 8 physical interfaces that require pluggable OC3/STM1 interfaces. This IOA can be combined with other half-height IOAs (except those that use the full capacity of a slot's bandwidth such as the GE-4 IOA). | 1.3.6.1.4.1.4874.4.2.3.1.9.4 | current | ||
| es2RedundancyS1Ioa OBJECT-IDENTITY E320 redundancy IOA. This is a series 1, full-height, single wide IOA and does not support any physical interfaces. | 1.3.6.1.4.1.4874.4.2.3.1.9.5 | current | ||
| es2Oc12Stm4x2PosS1Ioa OBJECT-IDENTITY E320 OC12/STM4-2 POS IOA. This is a series 1, half-height, single wide IOA that supports 2 physical interfaces that require pluggable OC12/STM4 interfaces. This IOA can be combined with other half-height IOAs (except those that use the full capacity of a slot's bandwidth such as the GE-4 IOA). | 1.3.6.1.4.1.4874.4.2.3.1.9.6 | current | ||
| es2Oc12Stm4x2AtmS1Ioa OBJECT-IDENTITY E320 OC12/STM4-2 ATM IOA. This is a series 1, half-height, single wide IOA that supports 2 physical interfaces that require pluggable OC12/STM4 interfaces. This IOA can be combined with other half-height IOAs (except those that use the full capacity of a slot's bandwidth such as the GE-4 IOA). | 1.3.6.1.4.1.4874.4.2.3.1.9.7 | current | ||
| es2dash10GeS1Ioa OBJECT-IDENTITY E320 10GE IOA. This is a series 1, full-height, single wide IOA that supports 2 physical interface that requires a pluggable 10GE interface. | 1.3.6.1.4.1.4874.4.2.3.1.9.8 | current | ||
| es2Ge8S1Ioa OBJECT-IDENTITY E320 GE-8 IOA. This is a series 1, half-height, single wide IOA that supports 8 physical interfaces that require pluggable GE transceivers. This IOA will support a configuration of 8 active or 4 active + 4 standby interfaces. | 1.3.6.1.4.1.4874.4.2.3.1.9.9 | current | ||
| es2dash10GePrS2Ioa OBJECT-IDENTITY E320 10GE IOA with port redundancy (PR). This is a series 2, full-height, single wide IOA that supports 2 physical interfaces (1 active + 1 standby) that require pluggable 10GE transceivers. | 1.3.6.1.4.1.4874.4.2.3.1.9.10 | current | ||
| es2Ge20S2Ioa OBJECT-IDENTITY E320 GE-20 IOA. This is a series 2, full-height, single wide IOA that supports 20 physical interfaces that require pluggable GE transceivers. This IOA will support a configuration of 20 active or 10 active + 10 standby interfaces. | 1.3.6.1.4.1.4874.4.2.3.1.9.11 | current |