Juniper-ERX-System-MIB
- Registered at
- 1.3.6.1.4.1.4874.2.2.17
- Last updated
- 2003-11-24 21:01
- Organization
- Juniper Networks, Inc.
- Revisions
- 2003-11-24 21:01, 2003-11-24 14:26, 2003-11-18 22:06, 2002-10-14 17:40, 2002-04-12 20:57, 2001-05-21 19:27, 2001-05-15 18:27, 2000-04-25 18:44, 2000-01-20 00:00, 1999-02-10 00:00
- Namespace
- juniper
- Source file
Juniper-ERX-System-MIB- Digest
sha256:6c6be366f0b2f2eff76c4adae80098deda27dbc5f6475e8ff27b6c388dd45857
Description
Deprecated MIB objects for managing ERX Edge Router system elements. See the generic E-series system MIB (Juniper-System-MIB) for the preferred definitions. If both MIBs are supported, using the corresponding varbinds from both MIBs to set the same object in a single PDU is not supported.
Contact
Juniper Networks, Inc. Postal: 10 Technology Park Drive Westford, MA 01886-3146 USA Tel: +1 978 589 5800 Email: mib@Juniper.net
Imports
| From | Symbols |
|---|---|
| IF-MIB | InterfaceIndexOrZero |
| Juniper-MIBs | juniMibs |
| Juniper-TC | JuniEnable |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DateAndTime, DisplayString, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB IF-MIB Juniper-ERX-System-MIB Juniper-MIBs Juniper-TC Juniper-UNI-SMI SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Textual conventions
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| JuniSysCardType TEXTUAL-CONVENTION The type of card in a system slot: unknown Unknown type. srp Switch/Route Processor. ct3 Channelized T3. oc3 OC-3 (SONET/SDH). ut3Atm Unchannelized T3 (ATM service). ut3Frame Unchannelized T3 (Frame service). ue3Atm Unchannelized E3 (ATM service). ue3Frame Uncahnnelized E3 (Frame service). ce1 Channelized E1. ct1 Channelized T1. dpfe Dual Port Fast Ethernet. oc12Pos OC-12 (POS/SDH). oc12Atm OC-12 (ATM service). oc3Pos Quad OC-3 (POS/SDH). oc3Atm Quad OC-3 (ATM service). ge Gigabit Ethernet. fe8 Fast Ethernet 8-port. oc3oc12Pos Generic OC3/OC12 POS (multi-personality). oc3oc12Atm Generic OC3/OC12 ATM (multi-personality). coc3oc12 Channelized generic OC3/OC12 (multi-personality). coc3 Channelized OC3. coc12 Channelized OC12. oc12Server OC-12 Rate Server Card. hssi High Speed Serial Interface. geFe Generic GE/FE (multi-personality). ct3P12 Channelized T3 12-port. v35 X.21/V.35 Card. ut3f12 Unchannelized T3 12-port. ue3f12 Unchannelized E3 12-port. coc3F3 OC-3 channelized to T3. coc12F3 OC-12 channelized to T3. cocxF3 12-port T3/E3 or OC3/OC12 (multi-personality). vts Virtual Tunnel Server. oc48 OC-48 (SONET/SDH). ut3Atm4 4-port Unchannelized T3 ATM. hybrid Generic ATM/POS/GE Hybrid (multi-personality). oc3AtmGe OC3 ATM 2-port Gigabit Ethernet 1-port. oc3AtmPos OC3 ATM 2-port OC3 POS 2-port. ge2 Gigabit Ethernet 2-port. | deprecated | |||
| JuniTimingSelector TEXTUAL-CONVENTION The system timing selector. A value of 1 corresponds to the primary timing selector. A value of 2 corresponds to the secondary timing selector. A value of 3 corresponds to the tertiary timing selector. A value of 4 indicates an error with the timing selector. | deprecated | |||
| JuniTimingSourceLineType TEXTUAL-CONVENTION The set of choices for line type timing. | deprecated | |||
| JuniTimingSourceType TEXTUAL-CONVENTION The set of selectable timing source types. The timing source type determines the timing source parameters. | deprecated |
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| juniERXSysTrap OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.17.0 | |||
| juniERXSysObjects OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.17.1 | |||
| juniERXSysGeneral OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.17.1.1 | |||
| juniERXSysChassisRev OBJECT-TYPE Chassis revision number. If unknown, the value 255 is reported. | 1.3.6.1.4.1.4874.2.2.17.1.1.1 | Integer32 (0..255) | read-only | deprecated |
| juniERXSysSwVersion OBJECT-TYPE Currently executing operational software version. | 1.3.6.1.4.1.4874.2.2.17.1.1.2 | DisplayString | read-only | deprecated |
| juniERXSysSwBuildDate OBJECT-TYPE Build date of currently executing operational software version. | 1.3.6.1.4.1.4874.2.2.17.1.1.3 | DisplayString | read-only | deprecated |
| juniERXSysRevertControl OBJECT-TYPE Global revert control: off Disable global revert. immediate All slots are to revert immediately (asap). timeOfDay All slots are to revert at time specified by juniRxSysRevertTimeOfDay. This object/value must be set concurrently with juniERXSysRevertTimeOfDay. | 1.3.6.1.4.1.4874.2.2.17.1.1.4 | INTEGER {off(0), immediate(1), timeOfDay(2)} | read-write | deprecated |
| juniERXSysRevertTimeOfDay OBJECT-TYPE The number of seconds past midnight on any given day at which time reverts are allowed to occur. This object must be set concurrently with juniERXSysRevertControl. | 1.3.6.1.4.1.4874.2.2.17.1.1.5 | Integer32 (0..86399) | read-write | deprecated |
| juniERXSysBootConfigControl OBJECT-TYPE System boot configuration control: file Revert to configuration settings specified by juniERXSysBootConfigFile. The juniERXSysBootConfigControl and juniERXSysBootConfigFile must be specified together in the same set request PDU. fileOnce Revert to configuration settings specified by juniERXSysBootConfigFile. Do not continue to use file after using it once. The juniERXSysBootConfigControl and juniERXSysBootConfigFile must be specified together in the same set request PDU. factoryDefaults Revert to factory default settings. runningConfiguration Revert to current settings. | 1.3.6.1.4.1.4874.2.2.17.1.1.6 | INTEGER {file(0), fileOnce(1), factoryDefaults(2), runningConfiguration(3)} | read-write | deprecated |
| juniERXSysBootBackupConfigControl OBJECT-TYPE System boot backup configuration control: file Revert to backup configuration settings specified by juniERXSysBootBackupConfigFile. The juniERXSysBootBackupConfigControl and juniERXSysBootBackupConfigFile must be specified together in the same set request PDU. factoryDefaults Revert to factory default settings. none Specify no backup. | 1.3.6.1.4.1.4874.2.2.17.1.1.7 | INTEGER {file(0), factoryDefaults(1), none(2)} | read-write | deprecated |
| juniERXSysBootForceBackupControl OBJECT-TYPE System boot force backup control: off Do not force revert to backup settings. on Do force revert to backup settings. | 1.3.6.1.4.1.4874.2.2.17.1.1.8 | INTEGER {off(0), on(1)} | read-write | deprecated |
| juniERXSysBootAutoRevertControl OBJECT-TYPE System boot auto revert control: default Use default auto-revert tolerances. never Never auto-revert to backup. set Set auto-revert settings at specified tolerances. | 1.3.6.1.4.1.4874.2.2.17.1.1.9 | INTEGER {default(0), never(1), set(2)} | read-write | deprecated |
| juniERXSysBootAutoRevertCountTolerance OBJECT-TYPE The auto-revert reboot count tolerance. This object cannot be set to zero, but may contain a zero value when the control is set to never(1). | 1.3.6.1.4.1.4874.2.2.17.1.1.10 | Unsigned32 (0..4294967294) | read-write | deprecated |
| juniERXSysBootAutoRevertTimeTolerance OBJECT-TYPE The auto-revert reboot time tolerance. This object cannot be set to zero, but will contain a zero value when the control is set to never(1). | 1.3.6.1.4.1.4874.2.2.17.1.1.11 | Unsigned32 (0..4294967294) | read-write | deprecated |
| juniERXSysBootReleaseFile OBJECT-TYPE The local boot release file name, with extension .rel. | 1.3.6.1.4.1.4874.2.2.17.1.1.12 | DisplayString (SIZE(0..128)) | read-write | deprecated |
| juniERXSysBootConfigFile OBJECT-TYPE The local boot configuration file name, with extension .cnf. The juniERXSysBootConfigControl and juniERXSysBootConfigFile must be specified together in the same set request PDU. | 1.3.6.1.4.1.4874.2.2.17.1.1.13 | DisplayString (SIZE(0..128)) | read-write | deprecated |
| juniERXSysBootBackupReleaseFile OBJECT-TYPE The local backup boot release file name, with extension .rel. | 1.3.6.1.4.1.4874.2.2.17.1.1.14 | DisplayString (SIZE(0..128)) | read-write | deprecated |
| juniERXSysBootBackupConfigFile OBJECT-TYPE The local backup boot configuration file name, with extension .cnf. The juniERXSysBootBackupConfigControl and juniERXSysBootBackupConfigFile must be specified together in the same set request PDU. | 1.3.6.1.4.1.4874.2.2.17.1.1.15 | DisplayString (SIZE(0..128)) | read-write | deprecated |
| juniERXSysAdminTimingSource OBJECT-TYPE The administrative timing source for the ERX system. The ERX periodically monitors the status of three timing sources, primary, secondary and tertiary. If the systems current timing source fails, the system will automatically downgrade to the next timing source. If the system is configured to automatically upgrade (juniERXSysTimingDisableAutoUpgrade is set to false(2)) the system will switch back to the higher timing source when it becomes available. A timing source failure can be detected by comparing the operational and admin timing sources. If they are not equal, the system has swapped timing sources because the administratively set value is in the error state. | 1.3.6.1.4.1.4874.2.2.17.1.1.16 | JuniTimingSelector | read-write | deprecated |
| juniERXSysOperTimingSource OBJECT-TYPE The operations timing source for the ERX system. The ERX periodically monitors the status of three timing sources, primary, secondary and tertiary. If the systems current timing source fails, the system will automatically downgrade to the next timing source. If the system is configured to automatically upgrade (juniERXSysTimingDisableAutoUpgrade is set to false(2)) the system will switch back to the higher timing source when it becomes available. | 1.3.6.1.4.1.4874.2.2.17.1.1.17 | JuniTimingSelector | read-only | deprecated |
| juniERXSysTimingDisableAutoUpgrade OBJECT-TYPE This object controls the automatic timing selector upgrade. Setting this object to true(1) will prevent automatic upgrade to the next highest timing selector. Setting this object to false(2) will enable the automatic upgrade of timing selectors. | 1.3.6.1.4.1.4874.2.2.17.1.1.18 | TruthValue | read-write | deprecated |
| juniERXSysTimingSelectorTable OBJECT-TYPE Table of system timing selectors. | 1.3.6.1.4.1.4874.2.2.17.1.1.19 | not-accessible | deprecated | |
| juniERXSysTimingSelectorEntry OBJECT-TYPE A table entry describing a system timing selector. | 1.3.6.1.4.1.4874.2.2.17.1.1.19.1 | not-accessible | deprecated | |
| juniERXSysTimingSelectorIndex OBJECT-TYPE The system timing selector index associated with this entry. | 1.3.6.1.4.1.4874.2.2.17.1.1.19.1.1 | JuniTimingSelector | not-accessible | deprecated |
| juniERXSysTimingSourceType OBJECT-TYPE The system timing source type for this entry. This object must be present when setting either the juniERXSysTimingSourceIfIndex or juniERXSysTimingSourceLine objects. Also, if the value of this object is set to timingInternal(2), no other objects should be simultanously set, otherwise the agent will return an error. | 1.3.6.1.4.1.4874.2.2.17.1.1.19.1.2 | JuniTimingSourceType | read-write | deprecated |
| juniERXSysTimingSourceIfIndex OBJECT-TYPE The ifIndex of the interface selected as the system timing source. The juniERXSysTimingSourceType object must be set to timingInterfaceIfIndex(1) otherwise setting this object will fail. | 1.3.6.1.4.1.4874.2.2.17.1.1.19.1.3 | InterfaceIndexOrZero | read-write | deprecated |
| juniERXSysTimingSourceLine OBJECT-TYPE The line type timing source for this entry. The juniRxSysTimingSourceType object must be set to timingLine(3) for the agent to accept a set to this object. | 1.3.6.1.4.1.4874.2.2.17.1.1.19.1.4 | JuniTimingSourceLineType | read-write | deprecated |
| juniERXSysTimingStatus OBJECT-TYPE The status associated with this system timing selector. | 1.3.6.1.4.1.4874.2.2.17.1.1.19.1.5 | INTEGER {timingStatusOk(1), timingStatusError(2), timingStatusUnknown(3)} | read-only | deprecated |
| juniERXSysMemUtilPct OBJECT-TYPE Percentage of system memory utilization. A value of -1 indicates the utilization is unknown. | 1.3.6.1.4.1.4874.2.2.17.1.1.20 | Integer32 (-1..100) | read-only | deprecated |
| juniERXSysMemCapacity OBJECT-TYPE The total memory capacity of the system. Negative values are returned when the capacity exceeds 2147483647; interpret the negative 32-bit integer as an unsigned 32-bit integer value. | 1.3.6.1.4.1.4874.2.2.17.1.1.21 | Integer32 | read-only | deprecated |
| juniERXSysHighMemUtilThreshold OBJECT-TYPE The value of system memory utilization, where if reached for the first time will generate a high memory utilization event to the management entity on this system. The value of this object must be greated than the value of juniERXSysAbatedMemUtilThreshold. | 1.3.6.1.4.1.4874.2.2.17.1.1.22 | Integer32 (1..100) | read-write | deprecated |
| juniERXSysAbatedMemUtilThreshold OBJECT-TYPE The value of system memory utilization that is used to determine when to generate an abated memory utilization event notification to the management entity on this system. The value of this object must be less than the value of juniERXSysHighMemUtilThreshold. The abated memory utilization trap is sent once if the high memory threshold was reached, and memory utilization falls to the value of this object. | 1.3.6.1.4.1.4874.2.2.17.1.1.23 | Integer32 (0..99) | read-write | deprecated |
| juniERXSysMemUtilTrapEnable OBJECT-TYPE Controls the sending of system memory utilization events. Setting the value of this object to true(1) will cause system memory utilization event notification, if they occur, to be sent to the management entity on this system. Setting the value of this object to false(2) will disable event notifications. | 1.3.6.1.4.1.4874.2.2.17.1.1.24 | TruthValue | read-write | deprecated |
| juniERXSysGeneralTrapEnable OBJECT-TYPE Controls whether a member of the set of ERX system notifications (traps) defined in this MIB or the counterpart notifications defined in the generic E-series system MIB (Juniper-System-MIB) will be initiated when the appropriate system event occures. Setting the value of this object to true(1) will enable the event notifications from this MIB, if they occur, to be sent to the management entity on this system, provided no other restrictions are in effect, instead of the counterparts from the generic system MIB. Setting the value of this object to false(2) will disable all event notifications defined in this MIB, enabling the ones from the generic system MIB. | 1.3.6.1.4.1.4874.2.2.17.1.1.25 | TruthValue | read-write | deprecated |
| juniERXSysFabric OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.17.1.2 | |||
| juniERXSysFabricSpeed OBJECT-TYPE Speed of switching fabric, in gigabits per second. | 1.3.6.1.4.1.4874.2.2.17.1.2.1 | Integer32 | read-only | deprecated |
| juniERXSysFabricRev OBJECT-TYPE Fabric revision number. If unknown, the value 255 is reported. | 1.3.6.1.4.1.4874.2.2.17.1.2.2 | Integer32 (0..255) | read-only | deprecated |
| juniERXSysNvs OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.17.1.3 | |||
| juniERXSysNvsStatus OBJECT-TYPE Status of non-volatile storage (NVS): notPresent NVS is not installed. writeProtected NVS is write-protected. volumeError Status poll of NVS failed. nearCapacity Utilization exceeds 85% of NVS capacity. ok NVS is operational, none of the preceding conditions apply. nearConfigCapacity Utilization exceeds the ability to save the running configuration. | 1.3.6.1.4.1.4874.2.2.17.1.3.1 | INTEGER {notPresent(0), writeProtected(1), volumeError(2), nearCapacity(3), ok(4), nearConfigCapacity(5)} | read-only | deprecated |
| juniERXSysNvsCapacity OBJECT-TYPE Capacity of NVS storage in megabytes. | 1.3.6.1.4.1.4874.2.2.17.1.3.2 | Integer32 | read-only | deprecated |
| juniERXSysNvsUtilPct OBJECT-TYPE Percentage of NVS storage used. A value of -1 indicates NVS utilization is unknown. | 1.3.6.1.4.1.4874.2.2.17.1.3.3 | Integer32 (-1..100) | read-only | deprecated |
| juniERXSysSlot OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.17.1.4 | |||
| juniERXSysSlotCount OBJECT-TYPE The number of slots in the system. | 1.3.6.1.4.1.4874.2.2.17.1.4.1 | Integer32 | read-only | deprecated |
| juniERXSysSlotTable OBJECT-TYPE Table of system slots. | 1.3.6.1.4.1.4874.2.2.17.1.4.2 | not-accessible | deprecated | |
| juniERXSysSlotEntry OBJECT-TYPE A table entry describing contents of a system slot. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1 | not-accessible | deprecated | |
| juniERXSysSlotIndex OBJECT-TYPE Slot number. NOTE: Slot numbers are zero-based. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.1 | Integer32 (0..255) | not-accessible | deprecated |
| juniERXSysSlotDescr OBJECT-TYPE Textual description of the card. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.2 | DisplayString (SIZE(0..63)) | read-only | deprecated |
| juniERXSysSlotCurrentCardType OBJECT-TYPE Type of card actually in the slot. This could be different from the type reported in juniERXSysSlotExpectedCardType, in which case it may be necessary to set juniERXSysSlotControl to 'flush' before this card can be made operational. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.3 | JuniSysCardType | read-only | deprecated |
| juniERXSysSlotRev OBJECT-TYPE Revision number of the card. If unknown, the value 255 is reported. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.4 | Integer32 (0..255) | read-only | deprecated |
| juniERXSysSlotAdminStatus OBJECT-TYPE Exerts administrative control to enable/disable the slot. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.5 | JuniEnable | read-write | deprecated |
| juniERXSysSlotOperStatus OBJECT-TYPE Status of the card. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.6 | INTEGER {unknown(0), empty(1), disabled(2), failed(3), booting(4), initializing(5), online(6), standby(7), inactive(8)} | read-only | deprecated |
| juniERXSysSlotDisableReason OBJECT-TYPE Indicates the condition causing the slot to be disabled: none Value when card is not disabled. unknown Unknown reason for disablement. assessing The slot content is being assessed (transient initialization state). admin The slot is administratively disabled. cardMismatch The current card type conflicts with configuration associated with a different card type that previously occupied the slot. fabricLimit Card resource requirements exceed available fabric capacity. imageError Software image for card is missing or invalid. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.7 | INTEGER {none(0), unknown(1), assessing(2), admin(3), cardMismatch(4), fabricLimit(5), imageError(6)} | read-only | deprecated |
| juniERXSysSlotExpectedCardType OBJECT-TYPE Type of card associated with this slot through prior presence. After the card is removed, this association persists (and inhibits operation of a different card type in this slot, if one is inserted) until juniERXSysSlotControl is set to 'flush'. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.8 | JuniSysCardType | read-only | deprecated |
| juniERXSysSlotControl OBJECT-TYPE Administrative control of this slot: noOperation Setting this value has no effect. flush Flushes configuration associated with a card type that previously occupied this slot. Used to explicitly confirm that the slot is now empty, or contains a different card type. Card must be disabled when this value is asserted. See description for juniERXSysSlotDisableReason. reset Resets the slot. forceFailover Forces the slot to failover to backup. noBoot Deconfigure primary release file for the slot. noBootBackup Deconfigure backup release file for the slot. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.9 | INTEGER {noOperation(0), flush(1), reset(2), forceFailover(3), noBoot(4), noBootBackup(5)} | read-write | deprecated |
| juniERXSysSlotCpuUtilPct OBJECT-TYPE Percentage of CPU utilization. A value of -1 indicates the utilization is unknown. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.10 | Integer32 (-1..100) | read-only | deprecated |
| juniERXSysSlotMemUtilPct OBJECT-TYPE Percentage of memory utilization. A value of -1 indicates the utilization is unknown. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.11 | Integer32 (-1..100) | read-only | deprecated |
| juniERXSysSlotIoaPresent OBJECT-TYPE Indicates whether the card's corresponding I/O adapter is present. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.12 | TruthValue | read-only | deprecated |
| juniERXSysSlotPortCount OBJECT-TYPE Number of physical ports for the EXPECTED card type for this slot. NOTE: In event of a card mismatch in this slot, the port count for the CURRENT card in this slot is not recognized/reported until the configuration for the EXPECTED card is explicitly flushed via juniERXSysSlotControl. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.13 | Integer32 | read-only | deprecated |
| juniERXSysSlotLastChange OBJECT-TYPE The value of sysUpTime when the value of juniERXSysSlotOperStatus last changed. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.14 | TimeTicks | read-only | deprecated |
| juniERXSysSlotRedundancyLockout OBJECT-TYPE Exerts administrative control to enable/disable Redundancy protection for the slot. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.15 | JuniEnable | read-write | deprecated |
| juniERXSysSlotRedundancyGroupId OBJECT-TYPE Identifies the Redundancy group as derived from hardware settings. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.16 | Unsigned32 | read-only | deprecated |
| juniERXSysSlotSpareServer OBJECT-TYPE True only if the line card in slot is a spare redundant server. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.17 | TruthValue | read-only | deprecated |
| juniERXSysSlotAssociatedSlot OBJECT-TYPE If the module is a primary card and the spare is acting on its behalf, then the value of this object is the slot number of the associated spare. If the module is a primary card and is active (not spared), then the value of this object is the cards actual slot number. If the module is a spare card and it is active, then the value of this object is the slot number of the primary card that is being spared for. If the module is a spare and it is inactive, then the value of this object is the its own slot number. If module is not part of a redundancy group, or the slot is empty, the value of this object is 255. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.18 | Integer32 | read-only | deprecated |
| juniERXSysSlotRevertControl OBJECT-TYPE Per-slot revert control: off Disable slot revert. immediate Slot is to revert immediately (asap). timeAndDate Slot is to revert at time specified by juniRxSysSlotRedundancyRevertTime. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.19 | INTEGER {off(0), immediate(1), timeAndDate(2)} | read-write | deprecated |
| juniERXSysSlotRedundancyRevertTime OBJECT-TYPE The date and time associated with the timeAndDate (delayed) revert operation. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.20 | DateAndTime | read-write | deprecated |
| juniERXSysSlotBootReleaseFile OBJECT-TYPE The local boot release file name for this slot, with extension .rel. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.21 | DisplayString (SIZE(0..128)) | read-write | deprecated |
| juniERXSysSlotBootBackupReleaseFile OBJECT-TYPE The local backup boot release file name for this slot, with extension .rel. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.22 | DisplayString (SIZE(0..128)) | read-write | deprecated |
| juniERXSysSlotSerialNumber OBJECT-TYPE The serial number of the card in this slot. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.23 | DisplayString (SIZE(0..10)) | read-only | deprecated |
| juniERXSysSlotAssemblyPartNumber OBJECT-TYPE The part number of the card in this slot. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.24 | DisplayString (SIZE(0..10)) | read-only | deprecated |
| juniERXSysSlotAssemblyRev OBJECT-TYPE The revision number of the card assembly in this slot. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.25 | DisplayString (SIZE(0..3)) | read-only | deprecated |
| juniERXSysSlotIoaSerialNumber OBJECT-TYPE The serial number of the I/O adaptor on the card in this slot. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.26 | DisplayString (SIZE(0..10)) | read-only | deprecated |
| juniERXSysSlotIoaAssemblyPartNumber OBJECT-TYPE The part number of the I/O adaptor on the card in this slot. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.27 | DisplayString (SIZE(0..10)) | read-only | deprecated |
| juniERXSysSlotIoaAssemblyRev OBJECT-TYPE The revision number of the I/O adaptor assembly on the card in this slot. | 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.28 | DisplayString (SIZE(0..3)) | read-only | deprecated |
| juniERXSysPort OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.17.1.5 | |||
| juniERXSysPortTable OBJECT-TYPE Table of system physical ports. The information in this table reflects the ports for the EXPECTED card type in each slot; in event of a card mismatch, this table permits navigation of the existing configuration of the expected card type. | 1.3.6.1.4.1.4874.2.2.17.1.5.1 | not-accessible | deprecated | |
| juniERXSysPortEntry OBJECT-TYPE A table entry describing a physical port of the system. | 1.3.6.1.4.1.4874.2.2.17.1.5.1.1 | not-accessible | deprecated | |
| juniERXSysPortIndex OBJECT-TYPE Port number of this physical port, relative to the slot in which it resides. Each physical port is uniquely distinguished by its slot/port pair. NOTE: Port numbers are zero-based. | 1.3.6.1.4.1.4874.2.2.17.1.5.1.1.1 | Integer32 (0..255) | not-accessible | deprecated |
| juniERXSysPortDescr OBJECT-TYPE Textual description of this port. | 1.3.6.1.4.1.4874.2.2.17.1.5.1.1.2 | DisplayString (SIZE(0..63)) | read-only | deprecated |
| juniERXSysPortType OBJECT-TYPE Type of the physical port: unknown Unknown port type. eth Ethernet. ct3 Channelized T3. oc3c OC-3c (SONET/SDH). ut3Atm Unchannelized T3 (ATM service). ut3Frame Unchannelized T3 (Frame service). ue3Atm Unchannelized E3 (ATM service). ue3Frame Unchannelized E3 (Frame service). ce1 Channelized E1. ct1 Channelized T1. oc12cPos OC-12c (POS/SDH). oc12cAtm OC-12c (ATM service). oc3cPos OC-3c (POS/SDH). oc3cAtm OC-3c (ATM service). coc3 Channelized OC-3. coc12 Channelized OC-12. server Tunnel Server (no physical ports). hssi High Speed Serial Interface. v35 X.21/V.35. oc48cPos OC-48c (POS/SDH). | 1.3.6.1.4.1.4874.2.2.17.1.5.1.1.3 | INTEGER {unknown(0), eth(1), ct3(2), oc3c(3), ut3Atm(4), ut3Frame(5), ue3Atm(6), ue3Frame(7), ce1(8), ct1(9), oc12cPos(10), oc12cAtm(11), oc3cPos(12), oc3cAtm(13), coc3(14), coc12(15), server(16), hssi(17), v35(18), oc48cPos(19)} | read-only | deprecated |
| juniERXSysPortIfIndex OBJECT-TYPE The ifIndex of the Interfaces MIB ifTable entry corresponding to this physical port; if zero, the ifIndex is unknown or does not exist. | 1.3.6.1.4.1.4874.2.2.17.1.5.1.1.4 | InterfaceIndexOrZero | read-only | deprecated |
| juniERXSysPower OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.17.1.6 | |||
| juniERXSysPowerTable OBJECT-TYPE Table of system power elements. | 1.3.6.1.4.1.4874.2.2.17.1.6.1 | not-accessible | deprecated | |
| juniERXSysPowerEntry OBJECT-TYPE A table entry describing status of a system power element. | 1.3.6.1.4.1.4874.2.2.17.1.6.1.1 | not-accessible | deprecated | |
| juniERXSysPowerIndex OBJECT-TYPE Arbitrary integer index to distinguish entries in this table. | 1.3.6.1.4.1.4874.2.2.17.1.6.1.1.1 | Integer32 (0..255) | not-accessible | deprecated |
| juniERXSysPowerDescr OBJECT-TYPE Textual description of this power element. | 1.3.6.1.4.1.4874.2.2.17.1.6.1.1.2 | DisplayString (SIZE(0..63)) | read-only | deprecated |
| juniERXSysPowerStatus OBJECT-TYPE The status of the power element: inactive No power available from this element. active Power available from this element. | 1.3.6.1.4.1.4874.2.2.17.1.6.1.1.3 | INTEGER {inactive(0), active(1)} | read-only | deprecated |
| juniERXSysTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.17.1.7 | |||
| juniERXSysTempFanStatus OBJECT-TYPE Status of fan subsystem. ok All components operational warning The fan subsystem has a non-critical failure. failed The fan subsystem has a critical failure, or has been removed, and is now non-operational. | 1.3.6.1.4.1.4874.2.2.17.1.7.1 | INTEGER {failed(0), ok(1), warning(2)} | read-only | deprecated |
| juniERXSysTempTable OBJECT-TYPE Table of system temperature sensors. Sensors are distributed across the chassis, at least one sensor per populated slot. | 1.3.6.1.4.1.4874.2.2.17.1.7.2 | not-accessible | deprecated | |
| juniERXSysTempEntry OBJECT-TYPE A table entry describing status of a temperature sensor. | 1.3.6.1.4.1.4874.2.2.17.1.7.2.1 | not-accessible | deprecated | |
| juniERXSysTempIndex OBJECT-TYPE Arbitrary integer index to distinguish sensors associated with the same chassis slot. | 1.3.6.1.4.1.4874.2.2.17.1.7.2.1.1 | Integer32 (0..255) | not-accessible | deprecated |
| juniERXSysTempDescr OBJECT-TYPE Textual description of this sensor. | 1.3.6.1.4.1.4874.2.2.17.1.7.2.1.2 | DisplayString (SIZE(0..63)) | read-only | deprecated |
| juniERXSysTempStatus OBJECT-TYPE The status of a temperature sensor: unknown unknown failed failed tooLow below nominal range nominal within nominal range tooHigh above nominal range tooLowWarning near lower limit tooHighWarning near upper limit | 1.3.6.1.4.1.4874.2.2.17.1.7.2.1.3 | INTEGER {unknown(0), failed(1), tooLow(2), nominal(3), tooHigh(4), tooLowWarning(5), tooHighWarning(6)} | read-only | deprecated |
| juniERXSysTempValue OBJECT-TYPE The temperature measured by this sensor in degrees Celsius. This measurement is valid only if the value of the corresponding juniERXSysTempStatus is nominal. | 1.3.6.1.4.1.4874.2.2.17.1.7.2.1.4 | Integer32 | read-only | deprecated |
| juniERXSysTempProtectionStatus OBJECT-TYPE Thermal protection status: monitoring monitoring inHoldOff hold off time has begun activatedHoldOffExpired hold off time has expired, the system is in thermal protection mode activatedTempTooHigh temperature too high, the system is in thermal protection mode | 1.3.6.1.4.1.4874.2.2.17.1.7.3 | INTEGER {monitoring(1), inHoldOff(2), activatedHoldOffExpired(3), activatedTempTooHigh(4)} | read-only | deprecated |
| juniERXSysTempProtectionHoldOffTime OBJECT-TYPE The time, in seconds, before the system enters thermal protection mode after a critical fan subsystem failure is detected. | 1.3.6.1.4.1.4874.2.2.17.1.7.4 | Integer32 (0..1200) | read-only | deprecated |
| juniERXSysTempProtectionHoldOffTimeRemaining OBJECT-TYPE The time remaining, in seconds, before the system enters thermal protection mode while the thermal protection status is set to inHoldOff. The value decrements every second until it reaches zero, and the status changes to activatedHoldOffExpired. When the thermal protection status is not inHoldOff or activatedHoldOffExpired, the value is set to the hold off time. | 1.3.6.1.4.1.4874.2.2.17.1.7.5 | Integer32 (0..1200) | read-only | deprecated |
| juniERXSysSubsystem OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.17.1.8 | |||
| juniERXSysSubsystemTable OBJECT-TYPE Table of subsystems. | 1.3.6.1.4.1.4874.2.2.17.1.8.1 | not-accessible | deprecated | |
| juniERXSysSubsystemEntry OBJECT-TYPE A table entry containing information pertaining to a subsystem. | 1.3.6.1.4.1.4874.2.2.17.1.8.1.1 | not-accessible | deprecated | |
| juniERXSysSubsystemIndex OBJECT-TYPE Subsystem number. | 1.3.6.1.4.1.4874.2.2.17.1.8.1.1.1 | Integer32 (0..255) | not-accessible | deprecated |
| juniERXSysSubsystemName OBJECT-TYPE The name of the subsystem. | 1.3.6.1.4.1.4874.2.2.17.1.8.1.1.2 | DisplayString (SIZE(0..128)) | read-only | deprecated |
| juniERXSysSubsystemControl OBJECT-TYPE Administrative control of this subsystem: noOperation Setting this value has no effect. noBoot Deconfigure primary release file for the subsystem. noBootBackup Deconfigure backup release file for the subsystem. | 1.3.6.1.4.1.4874.2.2.17.1.8.1.1.3 | INTEGER {noOperation(0), noBoot(1), noBootBackup(2)} | read-write | deprecated |
| juniERXSysSubsystemBootReleaseFile OBJECT-TYPE The local boot release file name for this subsystem, with extension .rel. | 1.3.6.1.4.1.4874.2.2.17.1.8.1.1.4 | DisplayString (SIZE(0..128)) | read-write | deprecated |
| juniERXSysSubsystemBootBackupReleaseFile OBJECT-TYPE The local backup boot release file name for this subsystem, with extension .rel. | 1.3.6.1.4.1.4874.2.2.17.1.8.1.1.5 | DisplayString (SIZE(0..128)) | read-write | deprecated |
| juniERXSysConformance OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.17.2 | |||
| juniERXSysCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.17.2.1 | |||
| juniERXSysGroups OBJECT-IDENTITY | 1.3.6.1.4.1.4874.2.2.17.2.2 |
Notifications
| Name | OID | Status |
|---|---|---|
| juniERXSysSlotOperStatusChange NOTIFICATION-TYPE Reports a status change for a slot. This trap is generated on a transition into a stable state (online or disabled) or on a transition out of online. | 1.3.6.1.4.1.4874.2.2.17.0.1 | deprecated |
| juniERXSysPowerStatusChange NOTIFICATION-TYPE Reports a change in the status of a power element. | 1.3.6.1.4.1.4874.2.2.17.0.2 | deprecated |
| juniERXSysTempFanStatusChange NOTIFICATION-TYPE Reports a transition between the three states of the fan subsystem. When the fan subsystem transitions to the failed state the thermal protection hold off time begins. | 1.3.6.1.4.1.4874.2.2.17.0.3 | deprecated |
| juniERXSysTempStatusChange NOTIFICATION-TYPE Reports a change in the temperature status. When the status transitions to the tooHigh state the system enters thermal protection mode. | 1.3.6.1.4.1.4874.2.2.17.0.4 | deprecated |
| juniERXSysHighMemUtil NOTIFICATION-TYPE Report system memory utilization has met the conditions of juniERXSysHighMemUtilThreshold. | 1.3.6.1.4.1.4874.2.2.17.0.5 | deprecated |
| juniERXSysAbatedMemUtil NOTIFICATION-TYPE Reports system memory utilization has met the conditions of juniERXSysAbatedMemUtilThreshold. | 1.3.6.1.4.1.4874.2.2.17.0.6 | deprecated |
| juniERXSysTempProtectionStatusChange NOTIFICATION-TYPE Notification about changes in the state of Thermal Protection. This notification is sent when the tempProtectionStatus changes. It is also sent when the holdOffTimeRemaining is 50% of the holdOffTime. | 1.3.6.1.4.1.4874.2.2.17.0.7 | deprecated |
Conformance
| Name | OID | Status |
|---|---|---|
| juniERXSysCompliance MODULE-COMPLIANCE Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when new slot information objects were added. | 1.3.6.1.4.1.4874.2.2.17.2.1.1 | obsolete |
| juniERXSysCompliance1 MODULE-COMPLIANCE Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when the timing group was added. | 1.3.6.1.4.1.4874.2.2.17.2.1.2 | obsolete |
| juniERXSysCompliance2 MODULE-COMPLIANCE Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when new memory information objects and notifications were added. | 1.3.6.1.4.1.4874.2.2.17.2.1.3 | obsolete |
| juniERXSysCompliance3 MODULE-COMPLIANCE Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when new system temperature information objects and notifications were added. | 1.3.6.1.4.1.4874.2.2.17.2.1.4 | obsolete |
| juniERXSysCompliance4 MODULE-COMPLIANCE Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when the general trap control object was added. | 1.3.6.1.4.1.4874.2.2.17.2.1.5 | obsolete |
| juniERXSysCompliance5 MODULE-COMPLIANCE The compliance statement for entities which implement the ERX System MIB. | 1.3.6.1.4.1.4874.2.2.17.2.1.6 | deprecated |
| juniERXSysGroup OBJECT-GROUP Obsolete collection of management objects pertaining to system capabilities in a Juniper product. This group became obsolete when new slot information objects were added. | 1.3.6.1.4.1.4874.2.2.17.2.2.1 | obsolete |
| juniERXSysNotifyGroup NOTIFICATION-GROUP Obsolete collection of management notifications pertaining to system operations in a Juniper product. This group became obsolete when new memory threshold notificaitons were added. | 1.3.6.1.4.1.4874.2.2.17.2.2.2 | obsolete |
| juniERXSysGeneralGroup OBJECT-GROUP Obsolete collection of management objects pertaining to general system capabilities in a Juniper product. This group became obsolete when new memory management objects were added. | 1.3.6.1.4.1.4874.2.2.17.2.2.3 | obsolete |
| juniERXSysFabricGroup OBJECT-GROUP A collection of management objects pertaining to system fabric capabilities in a Juniper product. | 1.3.6.1.4.1.4874.2.2.17.2.2.4 | deprecated |
| juniERXSysNvsGroup OBJECT-GROUP A collection of management objects pertaining to non-volitile storage subsystem capabilities in a Juniper product. | 1.3.6.1.4.1.4874.2.2.17.2.2.5 | deprecated |
| juniERXSysSlotGroup OBJECT-GROUP A collection of management objects pertaining to slot-specific system capabilities in a Juniper product. | 1.3.6.1.4.1.4874.2.2.17.2.2.6 | deprecated |
| juniERXSysPortGroup OBJECT-GROUP A collection of management objects pertaining to port-related system capabilities in a Juniper product. | 1.3.6.1.4.1.4874.2.2.17.2.2.7 | deprecated |
| juniERXSysPowerGroup OBJECT-GROUP A collection of management objects pertaining to the power subsystem capabilities in a Juniper product. | 1.3.6.1.4.1.4874.2.2.17.2.2.8 | deprecated |
| juniERXSysTemperatureGroup OBJECT-GROUP Obsolete collection of management objects pertaining to system temperature monitoring capabilities in a Juniper product. This group became obsolete when temperature shutdown parameters were added. | 1.3.6.1.4.1.4874.2.2.17.2.2.9 | obsolete |
| juniERXSysSubsystemGroup OBJECT-GROUP A collection of management objects pertaining to subsystem capabilities in a Juniper product. | 1.3.6.1.4.1.4874.2.2.17.2.2.10 | deprecated |
| juniERXSysTimingGroup OBJECT-GROUP A collection of management objects pertaining to system timing capabilities in a Juniper product. | 1.3.6.1.4.1.4874.2.2.17.2.2.11 | deprecated |
| juniERXSysGeneralGroup2 OBJECT-GROUP Obsolete collection of management objects pertaining to general system capabilities in a Juniper product. This group became obsolete when the general trap control object was added. | 1.3.6.1.4.1.4874.2.2.17.2.2.12 | obsolete |
| juniERXSysNotifyGroup2 NOTIFICATION-GROUP Obsolete collection of management notifications pertaining to system operations in a Juniper product. This group became obsolete when the tempProtectionStatusChange notification was added. | 1.3.6.1.4.1.4874.2.2.17.2.2.13 | obsolete |
| juniERXSysTemperatureGroup2 OBJECT-GROUP A collection of management objects pertaining to system temperature monitoring capabilities in a Juniper product. | 1.3.6.1.4.1.4874.2.2.17.2.2.14 | deprecated |
| juniERXSysNotifyGroup3 NOTIFICATION-GROUP A collection of management notifications pertaining to system operations in a Juniper product. | 1.3.6.1.4.1.4874.2.2.17.2.2.15 | deprecated |
| juniERXSysGeneralGroup3 OBJECT-GROUP A collection of management objects pertaining to general system capabilities in a Juniper product. | 1.3.6.1.4.1.4874.2.2.17.2.2.16 | deprecated |