MIBs Depot

Juniper-ERX-System-MIB

Registered at
1.3.6.1.4.1.4874.2.2.17
Last updated
2003-11-24 21:01
Organization
Juniper Networks, Inc.
Revisions
2003-11-24 21:01, 2003-11-24 14:26, 2003-11-18 22:06, 2002-10-14 17:40, 2002-04-12 20:57, 2001-05-21 19:27, 2001-05-15 18:27, 2000-04-25 18:44, 2000-01-20 00:00, 1999-02-10 00:00
Namespace
juniper
Source file
Juniper-ERX-System-MIB
Digest
sha256:6c6be366f0b2f2eff76c4adae80098deda27dbc5f6475e8ff27b6c388dd45857

Description

Deprecated MIB objects for managing ERX Edge Router system elements. See the generic E-series system MIB (Juniper-System-MIB) for the preferred definitions. If both MIBs are supported, using the corresponding varbinds from both MIBs to set the same object in a single PDU is not supported.

Contact

Juniper Networks, Inc. Postal: 10 Technology Park Drive Westford, MA 01886-3146 USA Tel: +1 978 589 5800 Email: mib@Juniper.net

Imports

FromSymbols
IF-MIBInterfaceIndexOrZero
Juniper-MIBsjuniMibs
Juniper-TCJuniEnable
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso
SNMPv2-TCDateAndTime, DisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IF-MIB
Juniper-ERX-System-MIB
Juniper-MIBs
Juniper-TC
Juniper-UNI-SMI
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
JuniSysCardType
TEXTUAL-CONVENTION
The type of card in a system slot: unknown Unknown type. srp Switch/Route Processor. ct3 Channelized T3. oc3 OC-3 (SONET/SDH). ut3Atm Unchannelized T3 (ATM service). ut3Frame Unchannelized T3 (Frame service). ue3Atm Unchannelized E3 (ATM service). ue3Frame Uncahnnelized E3 (Frame service). ce1 Channelized E1. ct1 Channelized T1. dpfe Dual Port Fast Ethernet. oc12Pos OC-12 (POS/SDH). oc12Atm OC-12 (ATM service). oc3Pos Quad OC-3 (POS/SDH). oc3Atm Quad OC-3 (ATM service). ge Gigabit Ethernet. fe8 Fast Ethernet 8-port. oc3oc12Pos Generic OC3/OC12 POS (multi-personality). oc3oc12Atm Generic OC3/OC12 ATM (multi-personality). coc3oc12 Channelized generic OC3/OC12 (multi-personality). coc3 Channelized OC3. coc12 Channelized OC12. oc12Server OC-12 Rate Server Card. hssi High Speed Serial Interface. geFe Generic GE/FE (multi-personality). ct3P12 Channelized T3 12-port. v35 X.21/V.35 Card. ut3f12 Unchannelized T3 12-port. ue3f12 Unchannelized E3 12-port. coc3F3 OC-3 channelized to T3. coc12F3 OC-12 channelized to T3. cocxF3 12-port T3/E3 or OC3/OC12 (multi-personality). vts Virtual Tunnel Server. oc48 OC-48 (SONET/SDH). ut3Atm4 4-port Unchannelized T3 ATM. hybrid Generic ATM/POS/GE Hybrid (multi-personality). oc3AtmGe OC3 ATM 2-port Gigabit Ethernet 1-port. oc3AtmPos OC3 ATM 2-port OC3 POS 2-port. ge2 Gigabit Ethernet 2-port.
deprecated
JuniTimingSelector
TEXTUAL-CONVENTION
The system timing selector. A value of 1 corresponds to the primary timing selector. A value of 2 corresponds to the secondary timing selector. A value of 3 corresponds to the tertiary timing selector. A value of 4 indicates an error with the timing selector.
deprecated
JuniTimingSourceLineType
TEXTUAL-CONVENTION
The set of choices for line type timing.
deprecated
JuniTimingSourceType
TEXTUAL-CONVENTION
The set of selectable timing source types. The timing source type determines the timing source parameters.
deprecated

Objects

NameOIDSyntaxAccessStatus
juniERXSysTrap
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.17.0
juniERXSysObjects
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.17.1
juniERXSysGeneral
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.17.1.1
juniERXSysChassisRev
OBJECT-TYPE
Chassis revision number. If unknown, the value 255 is reported.
1.3.6.1.4.1.4874.2.2.17.1.1.1Integer32 (0..255)read-onlydeprecated
juniERXSysSwVersion
OBJECT-TYPE
Currently executing operational software version.
1.3.6.1.4.1.4874.2.2.17.1.1.2DisplayStringread-onlydeprecated
juniERXSysSwBuildDate
OBJECT-TYPE
Build date of currently executing operational software version.
1.3.6.1.4.1.4874.2.2.17.1.1.3DisplayStringread-onlydeprecated
juniERXSysRevertControl
OBJECT-TYPE
Global revert control: off Disable global revert. immediate All slots are to revert immediately (asap). timeOfDay All slots are to revert at time specified by juniRxSysRevertTimeOfDay. This object/value must be set concurrently with juniERXSysRevertTimeOfDay.
1.3.6.1.4.1.4874.2.2.17.1.1.4INTEGER {off(0), immediate(1), timeOfDay(2)}read-writedeprecated
juniERXSysRevertTimeOfDay
OBJECT-TYPE
The number of seconds past midnight on any given day at which time reverts are allowed to occur. This object must be set concurrently with juniERXSysRevertControl.
1.3.6.1.4.1.4874.2.2.17.1.1.5Integer32 (0..86399)read-writedeprecated
juniERXSysBootConfigControl
OBJECT-TYPE
System boot configuration control: file Revert to configuration settings specified by juniERXSysBootConfigFile. The juniERXSysBootConfigControl and juniERXSysBootConfigFile must be specified together in the same set request PDU. fileOnce Revert to configuration settings specified by juniERXSysBootConfigFile. Do not continue to use file after using it once. The juniERXSysBootConfigControl and juniERXSysBootConfigFile must be specified together in the same set request PDU. factoryDefaults Revert to factory default settings. runningConfiguration Revert to current settings.
1.3.6.1.4.1.4874.2.2.17.1.1.6INTEGER {file(0), fileOnce(1), factoryDefaults(2), runningConfiguration(3)}read-writedeprecated
juniERXSysBootBackupConfigControl
OBJECT-TYPE
System boot backup configuration control: file Revert to backup configuration settings specified by juniERXSysBootBackupConfigFile. The juniERXSysBootBackupConfigControl and juniERXSysBootBackupConfigFile must be specified together in the same set request PDU. factoryDefaults Revert to factory default settings. none Specify no backup.
1.3.6.1.4.1.4874.2.2.17.1.1.7INTEGER {file(0), factoryDefaults(1), none(2)}read-writedeprecated
juniERXSysBootForceBackupControl
OBJECT-TYPE
System boot force backup control: off Do not force revert to backup settings. on Do force revert to backup settings.
1.3.6.1.4.1.4874.2.2.17.1.1.8INTEGER {off(0), on(1)}read-writedeprecated
juniERXSysBootAutoRevertControl
OBJECT-TYPE
System boot auto revert control: default Use default auto-revert tolerances. never Never auto-revert to backup. set Set auto-revert settings at specified tolerances.
1.3.6.1.4.1.4874.2.2.17.1.1.9INTEGER {default(0), never(1), set(2)}read-writedeprecated
juniERXSysBootAutoRevertCountTolerance
OBJECT-TYPE
The auto-revert reboot count tolerance. This object cannot be set to zero, but may contain a zero value when the control is set to never(1).
1.3.6.1.4.1.4874.2.2.17.1.1.10Unsigned32 (0..4294967294)read-writedeprecated
juniERXSysBootAutoRevertTimeTolerance
OBJECT-TYPE
The auto-revert reboot time tolerance. This object cannot be set to zero, but will contain a zero value when the control is set to never(1).
1.3.6.1.4.1.4874.2.2.17.1.1.11Unsigned32 (0..4294967294)read-writedeprecated
juniERXSysBootReleaseFile
OBJECT-TYPE
The local boot release file name, with extension .rel.
1.3.6.1.4.1.4874.2.2.17.1.1.12DisplayString (SIZE(0..128))read-writedeprecated
juniERXSysBootConfigFile
OBJECT-TYPE
The local boot configuration file name, with extension .cnf. The juniERXSysBootConfigControl and juniERXSysBootConfigFile must be specified together in the same set request PDU.
1.3.6.1.4.1.4874.2.2.17.1.1.13DisplayString (SIZE(0..128))read-writedeprecated
juniERXSysBootBackupReleaseFile
OBJECT-TYPE
The local backup boot release file name, with extension .rel.
1.3.6.1.4.1.4874.2.2.17.1.1.14DisplayString (SIZE(0..128))read-writedeprecated
juniERXSysBootBackupConfigFile
OBJECT-TYPE
The local backup boot configuration file name, with extension .cnf. The juniERXSysBootBackupConfigControl and juniERXSysBootBackupConfigFile must be specified together in the same set request PDU.
1.3.6.1.4.1.4874.2.2.17.1.1.15DisplayString (SIZE(0..128))read-writedeprecated
juniERXSysAdminTimingSource
OBJECT-TYPE
The administrative timing source for the ERX system. The ERX periodically monitors the status of three timing sources, primary, secondary and tertiary. If the systems current timing source fails, the system will automatically downgrade to the next timing source. If the system is configured to automatically upgrade (juniERXSysTimingDisableAutoUpgrade is set to false(2)) the system will switch back to the higher timing source when it becomes available. A timing source failure can be detected by comparing the operational and admin timing sources. If they are not equal, the system has swapped timing sources because the administratively set value is in the error state.
1.3.6.1.4.1.4874.2.2.17.1.1.16JuniTimingSelectorread-writedeprecated
juniERXSysOperTimingSource
OBJECT-TYPE
The operations timing source for the ERX system. The ERX periodically monitors the status of three timing sources, primary, secondary and tertiary. If the systems current timing source fails, the system will automatically downgrade to the next timing source. If the system is configured to automatically upgrade (juniERXSysTimingDisableAutoUpgrade is set to false(2)) the system will switch back to the higher timing source when it becomes available.
1.3.6.1.4.1.4874.2.2.17.1.1.17JuniTimingSelectorread-onlydeprecated
juniERXSysTimingDisableAutoUpgrade
OBJECT-TYPE
This object controls the automatic timing selector upgrade. Setting this object to true(1) will prevent automatic upgrade to the next highest timing selector. Setting this object to false(2) will enable the automatic upgrade of timing selectors.
1.3.6.1.4.1.4874.2.2.17.1.1.18TruthValueread-writedeprecated
juniERXSysTimingSelectorTable
OBJECT-TYPE
Table of system timing selectors.
1.3.6.1.4.1.4874.2.2.17.1.1.19not-accessibledeprecated
juniERXSysTimingSelectorEntry
OBJECT-TYPE
A table entry describing a system timing selector.
1.3.6.1.4.1.4874.2.2.17.1.1.19.1not-accessibledeprecated
juniERXSysTimingSelectorIndex
OBJECT-TYPE
The system timing selector index associated with this entry.
1.3.6.1.4.1.4874.2.2.17.1.1.19.1.1JuniTimingSelectornot-accessibledeprecated
juniERXSysTimingSourceType
OBJECT-TYPE
The system timing source type for this entry. This object must be present when setting either the juniERXSysTimingSourceIfIndex or juniERXSysTimingSourceLine objects. Also, if the value of this object is set to timingInternal(2), no other objects should be simultanously set, otherwise the agent will return an error.
1.3.6.1.4.1.4874.2.2.17.1.1.19.1.2JuniTimingSourceTyperead-writedeprecated
juniERXSysTimingSourceIfIndex
OBJECT-TYPE
The ifIndex of the interface selected as the system timing source. The juniERXSysTimingSourceType object must be set to timingInterfaceIfIndex(1) otherwise setting this object will fail.
1.3.6.1.4.1.4874.2.2.17.1.1.19.1.3InterfaceIndexOrZeroread-writedeprecated
juniERXSysTimingSourceLine
OBJECT-TYPE
The line type timing source for this entry. The juniRxSysTimingSourceType object must be set to timingLine(3) for the agent to accept a set to this object.
1.3.6.1.4.1.4874.2.2.17.1.1.19.1.4JuniTimingSourceLineTyperead-writedeprecated
juniERXSysTimingStatus
OBJECT-TYPE
The status associated with this system timing selector.
1.3.6.1.4.1.4874.2.2.17.1.1.19.1.5INTEGER {timingStatusOk(1), timingStatusError(2), timingStatusUnknown(3)}read-onlydeprecated
juniERXSysMemUtilPct
OBJECT-TYPE
Percentage of system memory utilization. A value of -1 indicates the utilization is unknown.
1.3.6.1.4.1.4874.2.2.17.1.1.20Integer32 (-1..100)read-onlydeprecated
juniERXSysMemCapacity
OBJECT-TYPE
The total memory capacity of the system. Negative values are returned when the capacity exceeds 2147483647; interpret the negative 32-bit integer as an unsigned 32-bit integer value.
1.3.6.1.4.1.4874.2.2.17.1.1.21Integer32read-onlydeprecated
juniERXSysHighMemUtilThreshold
OBJECT-TYPE
The value of system memory utilization, where if reached for the first time will generate a high memory utilization event to the management entity on this system. The value of this object must be greated than the value of juniERXSysAbatedMemUtilThreshold.
1.3.6.1.4.1.4874.2.2.17.1.1.22Integer32 (1..100)read-writedeprecated
juniERXSysAbatedMemUtilThreshold
OBJECT-TYPE
The value of system memory utilization that is used to determine when to generate an abated memory utilization event notification to the management entity on this system. The value of this object must be less than the value of juniERXSysHighMemUtilThreshold. The abated memory utilization trap is sent once if the high memory threshold was reached, and memory utilization falls to the value of this object.
1.3.6.1.4.1.4874.2.2.17.1.1.23Integer32 (0..99)read-writedeprecated
juniERXSysMemUtilTrapEnable
OBJECT-TYPE
Controls the sending of system memory utilization events. Setting the value of this object to true(1) will cause system memory utilization event notification, if they occur, to be sent to the management entity on this system. Setting the value of this object to false(2) will disable event notifications.
1.3.6.1.4.1.4874.2.2.17.1.1.24TruthValueread-writedeprecated
juniERXSysGeneralTrapEnable
OBJECT-TYPE
Controls whether a member of the set of ERX system notifications (traps) defined in this MIB or the counterpart notifications defined in the generic E-series system MIB (Juniper-System-MIB) will be initiated when the appropriate system event occures. Setting the value of this object to true(1) will enable the event notifications from this MIB, if they occur, to be sent to the management entity on this system, provided no other restrictions are in effect, instead of the counterparts from the generic system MIB. Setting the value of this object to false(2) will disable all event notifications defined in this MIB, enabling the ones from the generic system MIB.
1.3.6.1.4.1.4874.2.2.17.1.1.25TruthValueread-writedeprecated
juniERXSysFabric
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.17.1.2
juniERXSysFabricSpeed
OBJECT-TYPE
Speed of switching fabric, in gigabits per second.
1.3.6.1.4.1.4874.2.2.17.1.2.1Integer32read-onlydeprecated
juniERXSysFabricRev
OBJECT-TYPE
Fabric revision number. If unknown, the value 255 is reported.
1.3.6.1.4.1.4874.2.2.17.1.2.2Integer32 (0..255)read-onlydeprecated
juniERXSysNvs
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.17.1.3
juniERXSysNvsStatus
OBJECT-TYPE
Status of non-volatile storage (NVS): notPresent NVS is not installed. writeProtected NVS is write-protected. volumeError Status poll of NVS failed. nearCapacity Utilization exceeds 85% of NVS capacity. ok NVS is operational, none of the preceding conditions apply. nearConfigCapacity Utilization exceeds the ability to save the running configuration.
1.3.6.1.4.1.4874.2.2.17.1.3.1INTEGER {notPresent(0), writeProtected(1), volumeError(2), nearCapacity(3), ok(4), nearConfigCapacity(5)}read-onlydeprecated
juniERXSysNvsCapacity
OBJECT-TYPE
Capacity of NVS storage in megabytes.
1.3.6.1.4.1.4874.2.2.17.1.3.2Integer32read-onlydeprecated
juniERXSysNvsUtilPct
OBJECT-TYPE
Percentage of NVS storage used. A value of -1 indicates NVS utilization is unknown.
1.3.6.1.4.1.4874.2.2.17.1.3.3Integer32 (-1..100)read-onlydeprecated
juniERXSysSlot
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.17.1.4
juniERXSysSlotCount
OBJECT-TYPE
The number of slots in the system.
1.3.6.1.4.1.4874.2.2.17.1.4.1Integer32read-onlydeprecated
juniERXSysSlotTable
OBJECT-TYPE
Table of system slots.
1.3.6.1.4.1.4874.2.2.17.1.4.2not-accessibledeprecated
juniERXSysSlotEntry
OBJECT-TYPE
A table entry describing contents of a system slot.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1not-accessibledeprecated
juniERXSysSlotIndex
OBJECT-TYPE
Slot number. NOTE: Slot numbers are zero-based.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.1Integer32 (0..255)not-accessibledeprecated
juniERXSysSlotDescr
OBJECT-TYPE
Textual description of the card.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.2DisplayString (SIZE(0..63))read-onlydeprecated
juniERXSysSlotCurrentCardType
OBJECT-TYPE
Type of card actually in the slot. This could be different from the type reported in juniERXSysSlotExpectedCardType, in which case it may be necessary to set juniERXSysSlotControl to 'flush' before this card can be made operational.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.3JuniSysCardTyperead-onlydeprecated
juniERXSysSlotRev
OBJECT-TYPE
Revision number of the card. If unknown, the value 255 is reported.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.4Integer32 (0..255)read-onlydeprecated
juniERXSysSlotAdminStatus
OBJECT-TYPE
Exerts administrative control to enable/disable the slot.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.5JuniEnableread-writedeprecated
juniERXSysSlotOperStatus
OBJECT-TYPE
Status of the card.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.6INTEGER {unknown(0), empty(1), disabled(2), failed(3), booting(4), initializing(5), online(6), standby(7), inactive(8)}read-onlydeprecated
juniERXSysSlotDisableReason
OBJECT-TYPE
Indicates the condition causing the slot to be disabled: none Value when card is not disabled. unknown Unknown reason for disablement. assessing The slot content is being assessed (transient initialization state). admin The slot is administratively disabled. cardMismatch The current card type conflicts with configuration associated with a different card type that previously occupied the slot. fabricLimit Card resource requirements exceed available fabric capacity. imageError Software image for card is missing or invalid.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.7INTEGER {none(0), unknown(1), assessing(2), admin(3), cardMismatch(4), fabricLimit(5), imageError(6)}read-onlydeprecated
juniERXSysSlotExpectedCardType
OBJECT-TYPE
Type of card associated with this slot through prior presence. After the card is removed, this association persists (and inhibits operation of a different card type in this slot, if one is inserted) until juniERXSysSlotControl is set to 'flush'.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.8JuniSysCardTyperead-onlydeprecated
juniERXSysSlotControl
OBJECT-TYPE
Administrative control of this slot: noOperation Setting this value has no effect. flush Flushes configuration associated with a card type that previously occupied this slot. Used to explicitly confirm that the slot is now empty, or contains a different card type. Card must be disabled when this value is asserted. See description for juniERXSysSlotDisableReason. reset Resets the slot. forceFailover Forces the slot to failover to backup. noBoot Deconfigure primary release file for the slot. noBootBackup Deconfigure backup release file for the slot.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.9INTEGER {noOperation(0), flush(1), reset(2), forceFailover(3), noBoot(4), noBootBackup(5)}read-writedeprecated
juniERXSysSlotCpuUtilPct
OBJECT-TYPE
Percentage of CPU utilization. A value of -1 indicates the utilization is unknown.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.10Integer32 (-1..100)read-onlydeprecated
juniERXSysSlotMemUtilPct
OBJECT-TYPE
Percentage of memory utilization. A value of -1 indicates the utilization is unknown.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.11Integer32 (-1..100)read-onlydeprecated
juniERXSysSlotIoaPresent
OBJECT-TYPE
Indicates whether the card's corresponding I/O adapter is present.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.12TruthValueread-onlydeprecated
juniERXSysSlotPortCount
OBJECT-TYPE
Number of physical ports for the EXPECTED card type for this slot. NOTE: In event of a card mismatch in this slot, the port count for the CURRENT card in this slot is not recognized/reported until the configuration for the EXPECTED card is explicitly flushed via juniERXSysSlotControl.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.13Integer32read-onlydeprecated
juniERXSysSlotLastChange
OBJECT-TYPE
The value of sysUpTime when the value of juniERXSysSlotOperStatus last changed.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.14TimeTicksread-onlydeprecated
juniERXSysSlotRedundancyLockout
OBJECT-TYPE
Exerts administrative control to enable/disable Redundancy protection for the slot.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.15JuniEnableread-writedeprecated
juniERXSysSlotRedundancyGroupId
OBJECT-TYPE
Identifies the Redundancy group as derived from hardware settings.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.16Unsigned32read-onlydeprecated
juniERXSysSlotSpareServer
OBJECT-TYPE
True only if the line card in slot is a spare redundant server.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.17TruthValueread-onlydeprecated
juniERXSysSlotAssociatedSlot
OBJECT-TYPE
If the module is a primary card and the spare is acting on its behalf, then the value of this object is the slot number of the associated spare. If the module is a primary card and is active (not spared), then the value of this object is the cards actual slot number. If the module is a spare card and it is active, then the value of this object is the slot number of the primary card that is being spared for. If the module is a spare and it is inactive, then the value of this object is the its own slot number. If module is not part of a redundancy group, or the slot is empty, the value of this object is 255.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.18Integer32read-onlydeprecated
juniERXSysSlotRevertControl
OBJECT-TYPE
Per-slot revert control: off Disable slot revert. immediate Slot is to revert immediately (asap). timeAndDate Slot is to revert at time specified by juniRxSysSlotRedundancyRevertTime.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.19INTEGER {off(0), immediate(1), timeAndDate(2)}read-writedeprecated
juniERXSysSlotRedundancyRevertTime
OBJECT-TYPE
The date and time associated with the timeAndDate (delayed) revert operation.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.20DateAndTimeread-writedeprecated
juniERXSysSlotBootReleaseFile
OBJECT-TYPE
The local boot release file name for this slot, with extension .rel.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.21DisplayString (SIZE(0..128))read-writedeprecated
juniERXSysSlotBootBackupReleaseFile
OBJECT-TYPE
The local backup boot release file name for this slot, with extension .rel.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.22DisplayString (SIZE(0..128))read-writedeprecated
juniERXSysSlotSerialNumber
OBJECT-TYPE
The serial number of the card in this slot.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.23DisplayString (SIZE(0..10))read-onlydeprecated
juniERXSysSlotAssemblyPartNumber
OBJECT-TYPE
The part number of the card in this slot.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.24DisplayString (SIZE(0..10))read-onlydeprecated
juniERXSysSlotAssemblyRev
OBJECT-TYPE
The revision number of the card assembly in this slot.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.25DisplayString (SIZE(0..3))read-onlydeprecated
juniERXSysSlotIoaSerialNumber
OBJECT-TYPE
The serial number of the I/O adaptor on the card in this slot.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.26DisplayString (SIZE(0..10))read-onlydeprecated
juniERXSysSlotIoaAssemblyPartNumber
OBJECT-TYPE
The part number of the I/O adaptor on the card in this slot.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.27DisplayString (SIZE(0..10))read-onlydeprecated
juniERXSysSlotIoaAssemblyRev
OBJECT-TYPE
The revision number of the I/O adaptor assembly on the card in this slot.
1.3.6.1.4.1.4874.2.2.17.1.4.2.1.28DisplayString (SIZE(0..3))read-onlydeprecated
juniERXSysPort
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.17.1.5
juniERXSysPortTable
OBJECT-TYPE
Table of system physical ports. The information in this table reflects the ports for the EXPECTED card type in each slot; in event of a card mismatch, this table permits navigation of the existing configuration of the expected card type.
1.3.6.1.4.1.4874.2.2.17.1.5.1not-accessibledeprecated
juniERXSysPortEntry
OBJECT-TYPE
A table entry describing a physical port of the system.
1.3.6.1.4.1.4874.2.2.17.1.5.1.1not-accessibledeprecated
juniERXSysPortIndex
OBJECT-TYPE
Port number of this physical port, relative to the slot in which it resides. Each physical port is uniquely distinguished by its slot/port pair. NOTE: Port numbers are zero-based.
1.3.6.1.4.1.4874.2.2.17.1.5.1.1.1Integer32 (0..255)not-accessibledeprecated
juniERXSysPortDescr
OBJECT-TYPE
Textual description of this port.
1.3.6.1.4.1.4874.2.2.17.1.5.1.1.2DisplayString (SIZE(0..63))read-onlydeprecated
juniERXSysPortType
OBJECT-TYPE
Type of the physical port: unknown Unknown port type. eth Ethernet. ct3 Channelized T3. oc3c OC-3c (SONET/SDH). ut3Atm Unchannelized T3 (ATM service). ut3Frame Unchannelized T3 (Frame service). ue3Atm Unchannelized E3 (ATM service). ue3Frame Unchannelized E3 (Frame service). ce1 Channelized E1. ct1 Channelized T1. oc12cPos OC-12c (POS/SDH). oc12cAtm OC-12c (ATM service). oc3cPos OC-3c (POS/SDH). oc3cAtm OC-3c (ATM service). coc3 Channelized OC-3. coc12 Channelized OC-12. server Tunnel Server (no physical ports). hssi High Speed Serial Interface. v35 X.21/V.35. oc48cPos OC-48c (POS/SDH).
1.3.6.1.4.1.4874.2.2.17.1.5.1.1.3INTEGER {unknown(0), eth(1), ct3(2), oc3c(3), ut3Atm(4), ut3Frame(5), ue3Atm(6), ue3Frame(7), ce1(8), ct1(9), oc12cPos(10), oc12cAtm(11), oc3cPos(12), oc3cAtm(13), coc3(14), coc12(15), server(16), hssi(17), v35(18), oc48cPos(19)}read-onlydeprecated
juniERXSysPortIfIndex
OBJECT-TYPE
The ifIndex of the Interfaces MIB ifTable entry corresponding to this physical port; if zero, the ifIndex is unknown or does not exist.
1.3.6.1.4.1.4874.2.2.17.1.5.1.1.4InterfaceIndexOrZeroread-onlydeprecated
juniERXSysPower
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.17.1.6
juniERXSysPowerTable
OBJECT-TYPE
Table of system power elements.
1.3.6.1.4.1.4874.2.2.17.1.6.1not-accessibledeprecated
juniERXSysPowerEntry
OBJECT-TYPE
A table entry describing status of a system power element.
1.3.6.1.4.1.4874.2.2.17.1.6.1.1not-accessibledeprecated
juniERXSysPowerIndex
OBJECT-TYPE
Arbitrary integer index to distinguish entries in this table.
1.3.6.1.4.1.4874.2.2.17.1.6.1.1.1Integer32 (0..255)not-accessibledeprecated
juniERXSysPowerDescr
OBJECT-TYPE
Textual description of this power element.
1.3.6.1.4.1.4874.2.2.17.1.6.1.1.2DisplayString (SIZE(0..63))read-onlydeprecated
juniERXSysPowerStatus
OBJECT-TYPE
The status of the power element: inactive No power available from this element. active Power available from this element.
1.3.6.1.4.1.4874.2.2.17.1.6.1.1.3INTEGER {inactive(0), active(1)}read-onlydeprecated
juniERXSysTemperature
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.17.1.7
juniERXSysTempFanStatus
OBJECT-TYPE
Status of fan subsystem. ok All components operational warning The fan subsystem has a non-critical failure. failed The fan subsystem has a critical failure, or has been removed, and is now non-operational.
1.3.6.1.4.1.4874.2.2.17.1.7.1INTEGER {failed(0), ok(1), warning(2)}read-onlydeprecated
juniERXSysTempTable
OBJECT-TYPE
Table of system temperature sensors. Sensors are distributed across the chassis, at least one sensor per populated slot.
1.3.6.1.4.1.4874.2.2.17.1.7.2not-accessibledeprecated
juniERXSysTempEntry
OBJECT-TYPE
A table entry describing status of a temperature sensor.
1.3.6.1.4.1.4874.2.2.17.1.7.2.1not-accessibledeprecated
juniERXSysTempIndex
OBJECT-TYPE
Arbitrary integer index to distinguish sensors associated with the same chassis slot.
1.3.6.1.4.1.4874.2.2.17.1.7.2.1.1Integer32 (0..255)not-accessibledeprecated
juniERXSysTempDescr
OBJECT-TYPE
Textual description of this sensor.
1.3.6.1.4.1.4874.2.2.17.1.7.2.1.2DisplayString (SIZE(0..63))read-onlydeprecated
juniERXSysTempStatus
OBJECT-TYPE
The status of a temperature sensor: unknown unknown failed failed tooLow below nominal range nominal within nominal range tooHigh above nominal range tooLowWarning near lower limit tooHighWarning near upper limit
1.3.6.1.4.1.4874.2.2.17.1.7.2.1.3INTEGER {unknown(0), failed(1), tooLow(2), nominal(3), tooHigh(4), tooLowWarning(5), tooHighWarning(6)}read-onlydeprecated
juniERXSysTempValue
OBJECT-TYPE
The temperature measured by this sensor in degrees Celsius. This measurement is valid only if the value of the corresponding juniERXSysTempStatus is nominal.
1.3.6.1.4.1.4874.2.2.17.1.7.2.1.4Integer32read-onlydeprecated
juniERXSysTempProtectionStatus
OBJECT-TYPE
Thermal protection status: monitoring monitoring inHoldOff hold off time has begun activatedHoldOffExpired hold off time has expired, the system is in thermal protection mode activatedTempTooHigh temperature too high, the system is in thermal protection mode
1.3.6.1.4.1.4874.2.2.17.1.7.3INTEGER {monitoring(1), inHoldOff(2), activatedHoldOffExpired(3), activatedTempTooHigh(4)}read-onlydeprecated
juniERXSysTempProtectionHoldOffTime
OBJECT-TYPE
The time, in seconds, before the system enters thermal protection mode after a critical fan subsystem failure is detected.
1.3.6.1.4.1.4874.2.2.17.1.7.4Integer32 (0..1200)read-onlydeprecated
juniERXSysTempProtectionHoldOffTimeRemaining
OBJECT-TYPE
The time remaining, in seconds, before the system enters thermal protection mode while the thermal protection status is set to inHoldOff. The value decrements every second until it reaches zero, and the status changes to activatedHoldOffExpired. When the thermal protection status is not inHoldOff or activatedHoldOffExpired, the value is set to the hold off time.
1.3.6.1.4.1.4874.2.2.17.1.7.5Integer32 (0..1200)read-onlydeprecated
juniERXSysSubsystem
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.17.1.8
juniERXSysSubsystemTable
OBJECT-TYPE
Table of subsystems.
1.3.6.1.4.1.4874.2.2.17.1.8.1not-accessibledeprecated
juniERXSysSubsystemEntry
OBJECT-TYPE
A table entry containing information pertaining to a subsystem.
1.3.6.1.4.1.4874.2.2.17.1.8.1.1not-accessibledeprecated
juniERXSysSubsystemIndex
OBJECT-TYPE
Subsystem number.
1.3.6.1.4.1.4874.2.2.17.1.8.1.1.1Integer32 (0..255)not-accessibledeprecated
juniERXSysSubsystemName
OBJECT-TYPE
The name of the subsystem.
1.3.6.1.4.1.4874.2.2.17.1.8.1.1.2DisplayString (SIZE(0..128))read-onlydeprecated
juniERXSysSubsystemControl
OBJECT-TYPE
Administrative control of this subsystem: noOperation Setting this value has no effect. noBoot Deconfigure primary release file for the subsystem. noBootBackup Deconfigure backup release file for the subsystem.
1.3.6.1.4.1.4874.2.2.17.1.8.1.1.3INTEGER {noOperation(0), noBoot(1), noBootBackup(2)}read-writedeprecated
juniERXSysSubsystemBootReleaseFile
OBJECT-TYPE
The local boot release file name for this subsystem, with extension .rel.
1.3.6.1.4.1.4874.2.2.17.1.8.1.1.4DisplayString (SIZE(0..128))read-writedeprecated
juniERXSysSubsystemBootBackupReleaseFile
OBJECT-TYPE
The local backup boot release file name for this subsystem, with extension .rel.
1.3.6.1.4.1.4874.2.2.17.1.8.1.1.5DisplayString (SIZE(0..128))read-writedeprecated
juniERXSysConformance
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.17.2
juniERXSysCompliances
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.17.2.1
juniERXSysGroups
OBJECT-IDENTITY
1.3.6.1.4.1.4874.2.2.17.2.2

Notifications

NameOIDStatus
juniERXSysSlotOperStatusChange
NOTIFICATION-TYPE
Reports a status change for a slot. This trap is generated on a transition into a stable state (online or disabled) or on a transition out of online.
1.3.6.1.4.1.4874.2.2.17.0.1deprecated
juniERXSysPowerStatusChange
NOTIFICATION-TYPE
Reports a change in the status of a power element.
1.3.6.1.4.1.4874.2.2.17.0.2deprecated
juniERXSysTempFanStatusChange
NOTIFICATION-TYPE
Reports a transition between the three states of the fan subsystem. When the fan subsystem transitions to the failed state the thermal protection hold off time begins.
1.3.6.1.4.1.4874.2.2.17.0.3deprecated
juniERXSysTempStatusChange
NOTIFICATION-TYPE
Reports a change in the temperature status. When the status transitions to the tooHigh state the system enters thermal protection mode.
1.3.6.1.4.1.4874.2.2.17.0.4deprecated
juniERXSysHighMemUtil
NOTIFICATION-TYPE
Report system memory utilization has met the conditions of juniERXSysHighMemUtilThreshold.
1.3.6.1.4.1.4874.2.2.17.0.5deprecated
juniERXSysAbatedMemUtil
NOTIFICATION-TYPE
Reports system memory utilization has met the conditions of juniERXSysAbatedMemUtilThreshold.
1.3.6.1.4.1.4874.2.2.17.0.6deprecated
juniERXSysTempProtectionStatusChange
NOTIFICATION-TYPE
Notification about changes in the state of Thermal Protection. This notification is sent when the tempProtectionStatus changes. It is also sent when the holdOffTimeRemaining is 50% of the holdOffTime.
1.3.6.1.4.1.4874.2.2.17.0.7deprecated

Conformance

NameOIDStatus
juniERXSysCompliance
MODULE-COMPLIANCE
Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when new slot information objects were added.
1.3.6.1.4.1.4874.2.2.17.2.1.1obsolete
juniERXSysCompliance1
MODULE-COMPLIANCE
Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when the timing group was added.
1.3.6.1.4.1.4874.2.2.17.2.1.2obsolete
juniERXSysCompliance2
MODULE-COMPLIANCE
Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when new memory information objects and notifications were added.
1.3.6.1.4.1.4874.2.2.17.2.1.3obsolete
juniERXSysCompliance3
MODULE-COMPLIANCE
Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when new system temperature information objects and notifications were added.
1.3.6.1.4.1.4874.2.2.17.2.1.4obsolete
juniERXSysCompliance4
MODULE-COMPLIANCE
Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when the general trap control object was added.
1.3.6.1.4.1.4874.2.2.17.2.1.5obsolete
juniERXSysCompliance5
MODULE-COMPLIANCE
The compliance statement for entities which implement the ERX System MIB.
1.3.6.1.4.1.4874.2.2.17.2.1.6deprecated
juniERXSysGroup
OBJECT-GROUP
Obsolete collection of management objects pertaining to system capabilities in a Juniper product. This group became obsolete when new slot information objects were added.
1.3.6.1.4.1.4874.2.2.17.2.2.1obsolete
juniERXSysNotifyGroup
NOTIFICATION-GROUP
Obsolete collection of management notifications pertaining to system operations in a Juniper product. This group became obsolete when new memory threshold notificaitons were added.
1.3.6.1.4.1.4874.2.2.17.2.2.2obsolete
juniERXSysGeneralGroup
OBJECT-GROUP
Obsolete collection of management objects pertaining to general system capabilities in a Juniper product. This group became obsolete when new memory management objects were added.
1.3.6.1.4.1.4874.2.2.17.2.2.3obsolete
juniERXSysFabricGroup
OBJECT-GROUP
A collection of management objects pertaining to system fabric capabilities in a Juniper product.
1.3.6.1.4.1.4874.2.2.17.2.2.4deprecated
juniERXSysNvsGroup
OBJECT-GROUP
A collection of management objects pertaining to non-volitile storage subsystem capabilities in a Juniper product.
1.3.6.1.4.1.4874.2.2.17.2.2.5deprecated
juniERXSysSlotGroup
OBJECT-GROUP
A collection of management objects pertaining to slot-specific system capabilities in a Juniper product.
1.3.6.1.4.1.4874.2.2.17.2.2.6deprecated
juniERXSysPortGroup
OBJECT-GROUP
A collection of management objects pertaining to port-related system capabilities in a Juniper product.
1.3.6.1.4.1.4874.2.2.17.2.2.7deprecated
juniERXSysPowerGroup
OBJECT-GROUP
A collection of management objects pertaining to the power subsystem capabilities in a Juniper product.
1.3.6.1.4.1.4874.2.2.17.2.2.8deprecated
juniERXSysTemperatureGroup
OBJECT-GROUP
Obsolete collection of management objects pertaining to system temperature monitoring capabilities in a Juniper product. This group became obsolete when temperature shutdown parameters were added.
1.3.6.1.4.1.4874.2.2.17.2.2.9obsolete
juniERXSysSubsystemGroup
OBJECT-GROUP
A collection of management objects pertaining to subsystem capabilities in a Juniper product.
1.3.6.1.4.1.4874.2.2.17.2.2.10deprecated
juniERXSysTimingGroup
OBJECT-GROUP
A collection of management objects pertaining to system timing capabilities in a Juniper product.
1.3.6.1.4.1.4874.2.2.17.2.2.11deprecated
juniERXSysGeneralGroup2
OBJECT-GROUP
Obsolete collection of management objects pertaining to general system capabilities in a Juniper product. This group became obsolete when the general trap control object was added.
1.3.6.1.4.1.4874.2.2.17.2.2.12obsolete
juniERXSysNotifyGroup2
NOTIFICATION-GROUP
Obsolete collection of management notifications pertaining to system operations in a Juniper product. This group became obsolete when the tempProtectionStatusChange notification was added.
1.3.6.1.4.1.4874.2.2.17.2.2.13obsolete
juniERXSysTemperatureGroup2
OBJECT-GROUP
A collection of management objects pertaining to system temperature monitoring capabilities in a Juniper product.
1.3.6.1.4.1.4874.2.2.17.2.2.14deprecated
juniERXSysNotifyGroup3
NOTIFICATION-GROUP
A collection of management notifications pertaining to system operations in a Juniper product.
1.3.6.1.4.1.4874.2.2.17.2.2.15deprecated
juniERXSysGeneralGroup3
OBJECT-GROUP
A collection of management objects pertaining to general system capabilities in a Juniper product.
1.3.6.1.4.1.4874.2.2.17.2.2.16deprecated