MIBs Depot

JUNIPER-RPM-MIB

Registered at
1.3.6.1.4.1.2636.3.50.1
Last updated
2007-03-01 00:00
Organization
Juniper Networks, Inc.
Revisions
2007-03-01 00:00
Namespace
juniper
Source file
JUNIPER-RPM-MIB
Digest
sha256:c1bbb4de9193a8a7290c92abe76eb737eed2f0cde5991272487227a2c829e06a

Description

This mib provides data associated with the Realtime Performance Monitoring feature.

Contact

Juniper Technical Assistance Center Juniper Networks, Inc. 1133 Innovation Way Sunnyvale, CA 94089 E-mail: support@juniper.net

Imports

FromSymbols
DISMAN-PING-MIBpingCtlOwnerIndex, pingCtlTestName, pingProbeHistoryIndex
HCNUM-TCCounterBasedGauge64
JUNIPER-SMIjnxRpmMibRoot
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDateAndTime, DisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

DISMAN-PING-MIB
HCNUM-TC
IANAifType-MIB
IF-MIB
INET-ADDRESS-MIB
JUNIPER-RPM-MIB
JUNIPER-SMI
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Textual conventions

NameOIDSyntaxAccessStatus
JnxRpmCollectionType
TEXTUAL-CONVENTION
Each RPM entry can maintain several collections of probes and provide separate calculations over each collection. The types of collections include: currentTest -- the test currently being executed lastCompletedTest -- the most recently completed test movingAverage -- the 'n' most recent probes (n is configurable) allTests -- all the probes (since the entry was last reset). Objects with this type identify a specific collection.
current
JnxRpmMeasurementSet
TEXTUAL-CONVENTION
Over each collection of probes, RPM calculates statistics for several sets of measurements. These sets include the following: roundTripTime -- the set of round trip delays posRttJitter -- the set of positive round trip jitter measurements negRttJitter -- the set of negative round trip jitter measurements egress -- the set of outgoing (source to destination) one-way delays posEgressJitter -- the set of positive egress jitter measurements negEgressJitter -- the set of negative egress jitter measurements ingress -- the set of incoming (destination to source) one-way delays posIngressJitter -- the set of positive ingress jitter measurements negIngressJitter -- the set of negative ingress jitter measurements Objects with this type identify a specific set of measurements.
current
JnxRpmMeasurementType
TEXTUAL-CONVENTION
For each individual probe, several different measurements can be made. These include the following (all measurements are provided in units of microseconds): roundTripTime -- this is the delay between the the transmission of a probe and the arrival of its response. rttJitter -- this is the difference between the current round trip time measurement and the previous one. rttInterarrivalJitter -- An estimate of the statistical variance of a packet's interarrival time. Defined in rfc1889 as: J=J+(|D(i-1,i)|-J)/16 where J is the interarrival jitter and D(i-1, i) is the current round trip jitter measurement. egress -- this is the delay beween the transmission of a probe and its arrival at its destination. egressJitter -- this is the difference between the current egress delay the previous measurement. egressInterarrivalJitter -- similar to rttInterarrivalJitter, but applied to egress jitter measurements. ingress -- this is the delay between the transmission of a probe response and its arrival at its destination. ingressJitter -- this is the difference between the current ingress delay and the previous measurement. ingressInterarrivalJitter -- similar to rttInterarrivalJitter, but applied to ingress jitter measurements. Note, not all types of measurements will be performed for every probe. The jitter measurements are available only for those RPM entries that employ hardware timestamps. Further, the ingress & egress measurements are available only for those probe types that measure one-way delays or where hardware timestamps are employed and the one-way-hardware timestamp knob is enabled. In either case, the one-way delays must be less than the round trip times, otherwise they are discarded. Also note, due to clock synchronization artifacts, many one-way jitter measurements & calculations may include signifacant variations, in some cases orders of magnitude greater than the round trip times. Because of this, one-way jitter measurements will only be performed on samples which are less than 10 seconds apart.
current
JnxRpmPercentType
TEXTUAL-CONVENTION
Displays a percentage as decimal with 6 digits precision.
current
JnxRpmTimestampType
TEXTUAL-CONVENTION
This object identifies the type of timestamp used to obtain a measurement: software this indicates software based timestamps are used on both client and server. clientHardware this indicates hardware based timestamps are used on the RPM client. The RPM server is processed entirely in software. clientAndServerHardware this indicates hardware based timestamps are used on the RPM client and the server.
current

Objects

NameOIDSyntaxAccessStatus
jnxRpmResultsSampleTable
OBJECT-TYPE
This table provides measurements from the latest individual RPM probe samples. Within each sample, the specific measurement type is identified by jnxRpmResSampleType. Note, if the latest probe was unsuccessful, no measurement types will be available. See the definition of JnxRpmMeasurementType for details on the types of measurements available.
1.3.6.1.4.1.2636.3.50.1.1not-accessiblecurrent
jnxRpmResultsSampleEntry
OBJECT-TYPE
Each entry provides a specific measurement type for a single probe.
1.3.6.1.4.1.2636.3.50.1.1.1not-accessiblecurrent
jnxRpmResSampleType
OBJECT-TYPE
This object identifies the specific measurement type returned by jnxRpmResSampleValue.
1.3.6.1.4.1.2636.3.50.1.1.1.1JnxRpmMeasurementTypenot-accessiblecurrent
jnxRpmResSampleValue
OBJECT-TYPE
This object returns the measurement identified by the corresponding jnxRpmResSampleType.
1.3.6.1.4.1.2636.3.50.1.1.1.2Integer32read-onlycurrent
jnxRpmResSampleTsType
OBJECT-TYPE
This object identifies the type of timestamp used to obtain this measurement.
1.3.6.1.4.1.2636.3.50.1.1.1.3JnxRpmTimestampTyperead-onlycurrent
jnxRpmResSampleDate
OBJECT-TYPE
This object provides the date and time of when this measurement was obtained.
1.3.6.1.4.1.2636.3.50.1.1.1.4DateAndTimeread-onlycurrent
jnxRpmResultsSummaryTable
OBJECT-TYPE
This table provides a summary of the results for a specific RPM entry (identified by pingCtlOwnerIndex/pingCtlTestName). The scope of the summary is identified by jnxRpmResSumCollection.
1.3.6.1.4.1.2636.3.50.1.2not-accessiblecurrent
jnxRpmResultsSummaryEntry
OBJECT-TYPE
Each entry in the table provides a summary of the RPM results over a single collection of probes. For each RPM entry, there are several collections maintained: the current test, the most recently completed test, a configurable number of the most recent probes (aka 'moving average'), and a global collection representing all the probes. Each entry in this table summarizes the results for one of these collections.
1.3.6.1.4.1.2636.3.50.1.2.1not-accessiblecurrent
jnxRpmResSumCollection
OBJECT-TYPE
This object identifes the collection of probes over which the summary data represented by the other objects in this table applies. Note, if a collection type is not supported or not configured, it will not be instantiated in this table.
1.3.6.1.4.1.2636.3.50.1.2.1.1JnxRpmCollectionTypenot-accessiblecurrent
jnxRpmResSumSent
OBJECT-TYPE
This object provides the number of probes sent within the collection identified by jnxRpmResSumCollection.
1.3.6.1.4.1.2636.3.50.1.2.1.2Unsigned32read-onlycurrent
jnxRpmResSumReceived
OBJECT-TYPE
This object provides the number of probes received within the collection identified by jnxRpmResSumCollection.
1.3.6.1.4.1.2636.3.50.1.2.1.3Unsigned32read-onlycurrent
jnxRpmResSumPercentLost
OBJECT-TYPE
This object provides the percentage of probes lost within the collection identified by jnxRpmResSumCollection.
1.3.6.1.4.1.2636.3.50.1.2.1.4JnxRpmPercentTyperead-onlycurrent
jnxRpmResSumDate
OBJECT-TYPE
This object provides the date and time of when the most recent probe within the collection identified by jnxRpmResSumCollection was completed.
1.3.6.1.4.1.2636.3.50.1.2.1.5DateAndTimeread-onlycurrent
jnxRpmResultsCalculatedTable
OBJECT-TYPE
This table provides a set of calculated values for each RPM entry, for each collection of probes maintained within that entry, and for each supported measurement set within that collection of probes. Note, not all collection types will be available for every RPM Entry (identified by pingCtlOwnerIndex/pingCtlTestName). The jitter calculations are available only for those RPM entries that employ hardware timestamps. Further, the ingress & egress calculations are available only for those probe types that measure one-way delays or where hardware timestamps are employed and the one-way-hardware timestamp knob is enabled. In either case, the one-way delays must be less than the round trip times, otherwise they are discarded. Also, this table will skip over any measurement set for which there are 0 samples.
1.3.6.1.4.1.2636.3.50.1.3not-accessiblecurrent
jnxRpmResultsCalculatedEntry
OBJECT-TYPE
1.3.6.1.4.1.2636.3.50.1.3.1not-accessiblecurrent
jnxRpmResCalcSet
OBJECT-TYPE
This object identifies the measurement set upon which the calculations returned by the other objects in this table are based.
1.3.6.1.4.1.2636.3.50.1.3.1.1JnxRpmMeasurementSetnot-accessiblecurrent
jnxRpmResCalcSamples
OBJECT-TYPE
The number of samples used in this calculations.
1.3.6.1.4.1.2636.3.50.1.3.1.2Unsigned32read-onlycurrent
jnxRpmResCalcMin
OBJECT-TYPE
The minimum of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds.
1.3.6.1.4.1.2636.3.50.1.3.1.3Unsigned32read-onlycurrent
jnxRpmResCalcMax
OBJECT-TYPE
The maximum of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds.
1.3.6.1.4.1.2636.3.50.1.3.1.4Unsigned32read-onlycurrent
jnxRpmResCalcAverage
OBJECT-TYPE
The average of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds.
1.3.6.1.4.1.2636.3.50.1.3.1.5Unsigned32read-onlycurrent
jnxRpmResCalcPkToPk
OBJECT-TYPE
The difference between the minimum and maximum of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds.
1.3.6.1.4.1.2636.3.50.1.3.1.6Unsigned32read-onlycurrent
jnxRpmResCalcStdDev
OBJECT-TYPE
The standard deviation calculated over all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds.
1.3.6.1.4.1.2636.3.50.1.3.1.7Unsigned32read-onlycurrent
jnxRpmResCalcSum
OBJECT-TYPE
The sum of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds.
1.3.6.1.4.1.2636.3.50.1.3.1.8CounterBasedGauge64read-onlycurrent
jnxRpmHistorySampleTable
OBJECT-TYPE
This table provides measurements for individual RPM probe samples. In addition to the last completed sample, a configurable number of the most recent samples are available as well. Within each sample, the specific measurement type is identified by jnxRpmHistSampleType. Note, if probe was unsuccessful, no measurement types will be available for that history entry. See the definition of JnxRpmMeasurementType for details on the types of measurements available.
1.3.6.1.4.1.2636.3.50.1.4not-accessiblecurrent
jnxRpmHistorySampleEntry
OBJECT-TYPE
1.3.6.1.4.1.2636.3.50.1.4.1not-accessiblecurrent
jnxRpmHistSampleType
OBJECT-TYPE
This object identifies the specific measurement type returned by jnxRpmHistSampleValue.
1.3.6.1.4.1.2636.3.50.1.4.1.1JnxRpmMeasurementTypenot-accessiblecurrent
jnxRpmHistSampleValue
OBJECT-TYPE
This object returns the measurement identified by the corresponding jnxRpmHistSampleType.
1.3.6.1.4.1.2636.3.50.1.4.1.2Integer32read-onlycurrent
jnxRpmHistSampleTsType
OBJECT-TYPE
This object identifies the type of timestamp used to obtain this measurement.
1.3.6.1.4.1.2636.3.50.1.4.1.3JnxRpmTimestampTyperead-onlycurrent
jnxRpmHistorySummaryTable
OBJECT-TYPE
This table provides historical summary data for each collection of probes within each RPM Entry, similar to the jnxRpmResultsSummaryTable. In addition to the current summary, this table provides the same number of historical entries as the jnxRpmHistorySampleTable.
1.3.6.1.4.1.2636.3.50.1.5not-accessiblecurrent
jnxRpmHistorySummaryEntry
OBJECT-TYPE
1.3.6.1.4.1.2636.3.50.1.5.1not-accessiblecurrent
jnxRpmHistSumCollection
OBJECT-TYPE
Identifies the collection of probes whose results are summarized by this row. At this time, historical summaries are available only for the current test (currentTest(1)).
1.3.6.1.4.1.2636.3.50.1.5.1.1JnxRpmCollectionTypenot-accessiblecurrent
jnxRpmHistSumSent
OBJECT-TYPE
This object provides the number of probes sent within the collection identified by jnxRpmHistSumCollection.
1.3.6.1.4.1.2636.3.50.1.5.1.2Unsigned32read-onlycurrent
jnxRpmHistSumReceived
OBJECT-TYPE
This object provides the number of probes received within the collection identified by jnxRpmHistSumCollection.
1.3.6.1.4.1.2636.3.50.1.5.1.3Unsigned32read-onlycurrent
jnxRpmHistSumPercentLost
OBJECT-TYPE
This object provides the percentage of probes lost within the collection identified by jnxRpmHistSumCollection.
1.3.6.1.4.1.2636.3.50.1.5.1.4JnxRpmPercentTyperead-onlycurrent
jnxRpmHistoryCalculatedTable
OBJECT-TYPE
This table provides a set of calculated values for each RPM entry, for each collection of probes maintained within that entry, and for each supported calculated type within that collection of probes, similar to the jnxRpmResultsCalculatedTable. In addition to the current summary, this table provides the same number of historical entries as the jnxRpmHistorySampleTable.
1.3.6.1.4.1.2636.3.50.1.6not-accessiblecurrent
jnxRpmHistoryCalculatedEntry
OBJECT-TYPE
1.3.6.1.4.1.2636.3.50.1.6.1not-accessiblecurrent
jnxRpmHistCalcSet
OBJECT-TYPE
This object identifies the measurement set upon which the calculations returned by the other objects in this table are based.
1.3.6.1.4.1.2636.3.50.1.6.1.1JnxRpmMeasurementSetnot-accessiblecurrent
jnxRpmHistCalcSamples
OBJECT-TYPE
The number of samples used in this calculations.
1.3.6.1.4.1.2636.3.50.1.6.1.2Unsigned32read-onlycurrent
jnxRpmHistCalcMin
OBJECT-TYPE
The minimum of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds.
1.3.6.1.4.1.2636.3.50.1.6.1.3Unsigned32read-onlycurrent
jnxRpmHistCalcMax
OBJECT-TYPE
The maximum of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds.
1.3.6.1.4.1.2636.3.50.1.6.1.4Unsigned32read-onlycurrent
jnxRpmHistCalcAverage
OBJECT-TYPE
The average of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds.
1.3.6.1.4.1.2636.3.50.1.6.1.5Unsigned32read-onlycurrent
jnxRpmHistCalcPkToPk
OBJECT-TYPE
The difference between the minimum and maximum of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds.
1.3.6.1.4.1.2636.3.50.1.6.1.6Unsigned32read-onlycurrent
jnxRpmHistCalcStdDev
OBJECT-TYPE
The standard deviation calculated over all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds.
1.3.6.1.4.1.2636.3.50.1.6.1.7Unsigned32read-onlycurrent
jnxRpmHistCalcSum
OBJECT-TYPE
The sum of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds.
1.3.6.1.4.1.2636.3.50.1.6.1.8CounterBasedGauge64read-onlycurrent