JUNIPER-POWER-SUPPLY-UNIT-MIB
- Registered at
- 1.3.6.1.4.1.2636.3.58.1
- Last updated
- 2010-10-27 00:00
- Organization
- Juniper Networks, Inc.
- Revisions
- 2010-01-27 00:00, 2010-05-13 00:00, 2010-10-27 00:00
- Namespace
- juniper
- Source file
JUNIPER-POWER-SUPPLY-UNIT-MIB- Digest
sha256:fccaf2aff761060036a01da773a997706e60ad12dc81637e18c6ac9150e5d658
Description
The Juniper Supply Unit MIB definitions for enabling power monitoring and management of a juniper device.
Contact
Juniper Technical Assistance Center Juniper Networks, Inc. 1133 Innovation Way Sunnyvale, CA 94089 E-mail: support@juniper.net
Imports
| From | Symbols |
|---|---|
| JUNIPER-MIB | jnxContentsContainerIndex, jnxContentsL1Index, jnxContentsL2Index, jnxContentsL3Index |
| JUNIPER-SMI | jnxPsuMIBRoot |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
JUNIPER-MIB JUNIPER-POWER-SUPPLY-UNIT-MIB JUNIPER-SMI SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| jnxPsuNotifications OBJECT-IDENTITY | 1.3.6.1.4.1.2636.3.58.1.1 | |||
| jnxPsuObjects OBJECT-IDENTITY | 1.3.6.1.4.1.2636.3.58.1.2 | |||
| jnxPsuScalars OBJECT-IDENTITY | 1.3.6.1.4.1.2636.3.58.1.2.1 | |||
| jnxPsuAvailableDeviceCount OBJECT-TYPE Gives the number of PSU units available online in the System. | 1.3.6.1.4.1.2636.3.58.1.2.1.1 | INTEGER | read-only | current |
| jnxPsuAvailableAveragePowerSupply OBJECT-TYPE Gives the total average power that the System can supply from the available online units in Watts. | 1.3.6.1.4.1.2636.3.58.1.2.1.2 | INTEGER | read-only | current |
| jnxPsuAvailableMaxPowerSupply OBJECT-TYPE Gives the total maximum power that the System can supply from the available online units in Watts. | 1.3.6.1.4.1.2636.3.58.1.2.1.3 | INTEGER | read-only | current |
| jnxPsuRedundancy OBJECT-TYPE PSU power redundancy configuration. | 1.3.6.1.4.1.2636.3.58.1.2.1.4 | INTEGER {nPlusNRedundancy(1), nPlusOneRedundancy(2), none(3)} | read-only | current |
| jnxPsuChassisPowerReserved OBJECT-TYPE Power reserved for Chassis in Watts. | 1.3.6.1.4.1.2636.3.58.1.2.1.5 | INTEGER | read-only | current |
| jnxPsuChassisPowerAllocated OBJECT-TYPE Total power allocated for chassis and all the FPCs in Watts. | 1.3.6.1.4.1.2636.3.58.1.2.1.6 | INTEGER | read-only | current |
| jnxPsuRedundantPowerAvailable OBJECT-TYPE Power(in Watts) that is still available for allocation even while supporting redundancy with the present usage. | 1.3.6.1.4.1.2636.3.58.1.2.1.7 | INTEGER | read-only | current |
| jnxPsuTotalPowerAvailable OBJECT-TYPE Power(in Watts) which could be made available for further allocation without supporting any redundancy with the present usage. | 1.3.6.1.4.1.2636.3.58.1.2.1.8 | INTEGER | read-only | current |
| jnxPsuChassisPowerConsumed OBJECT-TYPE Total power consumed by the entire system rounded to the nearest integer. This is calculated using the PowerFactor, Current and Voltage values of each PSU that is online and connected to the System. | 1.3.6.1.4.1.2636.3.58.1.2.1.9 | INTEGER | read-only | current |
| jnxPsuTemperatureInflow OBJECT-TYPE Average inflow temperature calculated from all the available input sensors on the master RE. | 1.3.6.1.4.1.2636.3.58.1.2.1.10 | INTEGER | read-only | current |
| jnxPsuTemperatureOutflow OBJECT-TYPE Average outflow temperature calculated from all the available output sensors on the master RE. | 1.3.6.1.4.1.2636.3.58.1.2.1.11 | INTEGER | read-only | current |
| jnxPsuTemperatureInflowSamples OBJECT-TYPE The number of samples being taken while calculating jnxPsuTemperatureInflow. | 1.3.6.1.4.1.2636.3.58.1.2.1.12 | INTEGER | read-only | current |
| jnxPsuTemperatureOutflowSamples OBJECT-TYPE The number of samples being taken while calculating jnxPsuTemperatureOutflow. | 1.3.6.1.4.1.2636.3.58.1.2.1.13 | INTEGER | read-only | current |
| jnxPsuTable OBJECT-TYPE A list of power entries for each PSU component. | 1.3.6.1.4.1.2636.3.58.1.2.2 | not-accessible | current | |
| jnxPsuEntry OBJECT-TYPE Defines an entry in jnxPsuTable. | 1.3.6.1.4.1.2636.3.58.1.2.2.1 | not-accessible | current | |
| jnxPsuAvgPower OBJECT-TYPE Buffer that contains the average power used, in Watts for each component. | 1.3.6.1.4.1.2636.3.58.1.2.2.1.1 | INTEGER | read-only | current |
| jnxPsuMaxPower OBJECT-TYPE Buffer that contains the max power available, in Watts for each component. | 1.3.6.1.4.1.2636.3.58.1.2.2.1.2 | INTEGER | read-only | current |
| jnxPsuMode OBJECT-TYPE Mode for each PSU component. | 1.3.6.1.4.1.2636.3.58.1.2.2.1.3 | INTEGER {single(1), three(3)} | read-only | current |
| jnxPsuOutletCount OBJECT-TYPE The number of outlets (regardless of their current state) present on this psu component, default is 0. | 1.3.6.1.4.1.2636.3.58.1.2.2.1.4 | INTEGER | read-only | current |
| jnxPsuEnvironmentTable OBJECT-TYPE A list of PSU Environment entries. | 1.3.6.1.4.1.2636.3.58.1.2.3 | not-accessible | current | |
| jnxPsuEnvironmentEntry OBJECT-TYPE Defines an entry in jnxPsuEnvironmentTable. | 1.3.6.1.4.1.2636.3.58.1.2.3.1 | not-accessible | current | |
| jnxPsuThermalValue OBJECT-TYPE Temparature at each component in degrees Celsius rounded to the nearest integer. | 1.3.6.1.4.1.2636.3.58.1.2.3.1.1 | INTEGER | read-only | current |
| jnxPsuHumidityValue OBJECT-TYPE Humidity at each component in percentage. | 1.3.6.1.4.1.2636.3.58.1.2.3.1.2 | INTEGER | read-only | current |
| jnxPsuOutletTable OBJECT-TYPE Gives details of each Power outlet`s state, capacity to supply power, and other details. | 1.3.6.1.4.1.2636.3.58.1.2.4 | not-accessible | current | |
| jnxPsuOutletEntry OBJECT-TYPE A value contained within the OutletEntry | 1.3.6.1.4.1.2636.3.58.1.2.4.1 | not-accessible | current | |
| jnxPsuOutletName OBJECT-TYPE Outlet name associated to the power supply unit for each PSU Component. | 1.3.6.1.4.1.2636.3.58.1.2.4.1.1 | DisplayString (SIZE(0..15)) | read-only | current |
| jnxPsuOutletDescription OBJECT-TYPE Outlet description associated to the power supply unit for each PSU Component. | 1.3.6.1.4.1.2636.3.58.1.2.4.1.2 | DisplayString (SIZE(0..63)) | read-only | current |
| jnxPsuOutletAvgPower OBJECT-TYPE Buffer that contains the average power used, in Watts for each component. | 1.3.6.1.4.1.2636.3.58.1.2.4.1.3 | INTEGER | read-only | current |
| jnxPsuOutletMaxPower OBJECT-TYPE Buffer that contains the maximum power available, in Watts for each component. | 1.3.6.1.4.1.2636.3.58.1.2.4.1.4 | INTEGER | read-only | current |
| jnxPsuOutletCurrent OBJECT-TYPE PSU output current in milliamps rounded to the nearest integer. | 1.3.6.1.4.1.2636.3.58.1.2.4.1.5 | INTEGER | read-only | current |
| jnxPsuOutletStatus OBJECT-TYPE The value of the operational status for the given outlet. This can also be used to set the outlet state | 1.3.6.1.4.1.2636.3.58.1.2.4.1.8 | INTEGER {off(0), on(1)} | read-only | current |
| jnxPsuOutletVoltage OBJECT-TYPE Output voltage in Volts rounded to the nearest integer. | 1.3.6.1.4.1.2636.3.58.1.2.4.1.9 | INTEGER | read-only | current |
| jnxPsuOutletPowerFactorValue OBJECT-TYPE Power factor percentage of each PSU (2k/3k). Algorithm for calculation of Power Factor is below. For PowerOut values that fall in between 618.93W and 915.24W, say 700W, the appropriate PF ranges from 0.910191 & 0.917994. Following linear equation could help deduce a fairly accurate input power value. Linear equation y = mx + b (where m is the slope and b is the Y intercept) Slope m = (y2 - y1) / (x2 - x1) Y intercept b = y - mx Plugging it all together for our example: m = (915.24 - 618.93) / (0.917994 - 0.910191) = 37973.86 b = 915.24 - (37973.86 * 0.917994) = -33944.5 for 700W (y), our efficiency (x) would then be: x = (700 - (-33944.5)) / 37973.86 = 0.912326 = 91% PowerIn = 700W /0.912326 = 767.26W | 1.3.6.1.4.1.2636.3.58.1.2.4.1.10 | INTEGER | read-only | current |
| jnxPsuOutletPowerConsumed OBJECT-TYPE Power Consumed by each outlet units in Watts. | 1.3.6.1.4.1.2636.3.58.1.2.4.1.11 | INTEGER | read-only | current |
| jnxPsuFpcPowerTable OBJECT-TYPE A list of entries for each FPC(Flexible PIC Concentrator) giving it's assigned priority and power being allocated. More information on FPCs can be found in JUNIPER-MIB. | 1.3.6.1.4.1.2636.3.58.1.2.5 | not-accessible | current | |
| jnxPsuFpcPowerEntry OBJECT-TYPE A value contained within the FpcPowerEntry | 1.3.6.1.4.1.2636.3.58.1.2.5.1 | not-accessible | current | |
| jnxPsuFpcPowerPriority OBJECT-TYPE The Power budget priority assigned to the FPC. Lower number means higher priority. | 1.3.6.1.4.1.2636.3.58.1.2.5.1.1 | INTEGER | read-only | current |
| jnxPsuFpcPowerAllocated OBJECT-TYPE The Power allocated to the FPC in Watts. | 1.3.6.1.4.1.2636.3.58.1.2.5.1.2 | INTEGER | read-only | current |