MIBs Depot

JUNIPER-ALARM-MIB

Registered at
1.3.6.1.4.1.2636.3.4
Last updated
2003-07-18 21:53
Organization
Juniper Networks, Inc.
Namespace
juniper
Source file
JUNIPER-ALARM-MIB
Digest
sha256:e5064e7d5d87522393e04cca95511f287a88b838c4ff7d1d5b86159597e30c13

Description

This is Juniper Networks' implementation of enterprise specific MIB for alarms from the router chassis box.

Contact

Juniper Technical Assistance Center Juniper Networks, Inc. 1133 Innovation Way Sunnyvale, CA 94089 E-mail: support@juniper.net

Imports

FromSymbols
JUNIPER-SMIjnxMibs
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIGauge32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TimeStamp

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

JUNIPER-ALARM-MIB
JUNIPER-SMI
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
jnxCraftAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.2636.3.4.2
jnxAlarmRelayMode
OBJECT-TYPE
The alarm relay mode of the craft interface panel for both yellow and red alarms. Both yellow and red alarms could be cut off by a front panel Alarm Cutoff / Lamp Test (ACO/LT) button. In the pass-on mode, the alarm relay will be activated to pass on the yellow or red alarms. In the cut-off mode, both yellow and red alarms will be cut off from the alarm relays which are normally connected to audible sirens or visual flashing devices.
1.3.6.1.4.1.2636.3.4.2.1INTEGER {other(1), passOn(2), cutOff(3)}read-onlycurrent
jnxYellowAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.2636.3.4.2.2
jnxYellowAlarmState
OBJECT-TYPE
The yellow alarm state on the craft interface panel. The yellow alarm is on when there is some system warning such as maintenance alert or significant temperature increase. This yellow alarm state could be turned off by the ACO/LT (Alarm Cut Off / Lamp Test) button on the front panel module.
1.3.6.1.4.1.2636.3.4.2.2.1INTEGER {other(1), off(2), on(3)}read-onlycurrent
jnxYellowAlarmCount
OBJECT-TYPE
The number of currently active and non-silent yellow alarms. This object is independent of the ACO/LT (Alarm Cut Off / Lamp Test) button.
1.3.6.1.4.1.2636.3.4.2.2.2Gauge32read-onlycurrent
jnxYellowAlarmLastChange
OBJECT-TYPE
The value of sysUpTime when the yellow alarm last changed - either from off to on or vice versa. Zero if unknown or never changed since the agent was up.
1.3.6.1.4.1.2636.3.4.2.2.3TimeStampread-onlycurrent
jnxRedAlarms
OBJECT-IDENTITY
1.3.6.1.4.1.2636.3.4.2.3
jnxRedAlarmState
OBJECT-TYPE
The red alarm indication on the craft interface panel. The red alarm is on when there is some system failure or power supply failure or the system is experiencing a hardware malfunction or some threshold is being exceeded. This red alarm state could be turned off by the ACO/LT (Alarm Cut Off / Lamp Test) button on the front panel module.
1.3.6.1.4.1.2636.3.4.2.3.1INTEGER {other(1), off(2), on(3)}read-onlycurrent
jnxRedAlarmCount
OBJECT-TYPE
The number of currently active and non-silent red alarms. This object is independent of the ACO/LT (Alarm Cut Off / Lamp Test) button.
1.3.6.1.4.1.2636.3.4.2.3.2Gauge32read-onlycurrent
jnxRedAlarmLastChange
OBJECT-TYPE
The value of sysUpTime when the red alarm last changed - either from off to on or vice versa. Zero if unknown or never changed since the agent was up.