Objects

NameOIDSyntaxAccessStatus
jacarta
OBJECT-IDENTITY
1.3.6.1.4.1.19011
product
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1
webAppliance
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3
inSept
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1
inSeptObjects
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1
inSeptIdent
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.1
inSeptIdentManufacturer
OBJECT-TYPE
The name of the interSeptor manufacturer.
1.3.6.1.4.1.19011.1.3.1.1.1.1DisplayString (SIZE(0..31))read-onlymandatory
inSeptIdentModel
OBJECT-TYPE
The interSeptor Model designation.
1.3.6.1.4.1.19011.1.3.1.1.1.2DisplayString (SIZE(0..63))read-onlymandatory
inSeptIdentAgentSoftwareVersion
OBJECT-TYPE
The interSeptor software/firmware version.
1.3.6.1.4.1.19011.1.3.1.1.1.3DisplayString (SIZE(0..31))read-onlymandatory
inSeptIdentName
OBJECT-TYPE
A string identifying the interSeptor. This object should be set by the administrator.
1.3.6.1.4.1.19011.1.3.1.1.1.4DisplayString (SIZE(0..31))read-writemandatory
inSeptConfig
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.2
inSeptConfigMibVersion
OBJECT-TYPE
The version of MIB spec.
1.3.6.1.4.1.19011.1.3.1.1.2.1INTEGERread-onlymandatory
inSeptConfigNetwork
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.2.2
inSeptConfigIpAddress
OBJECT-TYPE
The ip address that NMS can identify the managed device
1.3.6.1.4.1.19011.1.3.1.1.2.2.1IpAddressread-writemandatory
inSeptConfigGateway
OBJECT-TYPE
The default gateway that allows the device to be managed through routers
1.3.6.1.4.1.19011.1.3.1.1.2.2.2IpAddressread-writemandatory
inSeptConfigSubnetMask
OBJECT-TYPE
Internet address subnet mask
1.3.6.1.4.1.19011.1.3.1.1.2.2.3IpAddressread-writemandatory
inSeptConfigDateTime
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.2.3
inSeptConfigDate
OBJECT-TYPE
The date in inSept, format is (dd/mm/yyyy)
1.3.6.1.4.1.19011.1.3.1.1.2.3.1DisplayString (SIZE(10))read-writemandatory
inSeptConfigTime
OBJECT-TYPE
The time in interSeptor, format is (hh:mm:ss)
1.3.6.1.4.1.19011.1.3.1.1.2.3.2DisplayString (SIZE(8))read-writemandatory
inSeptConfigTimeFromNtp
OBJECT-TYPE
Enable/disable update date/time from NTP server.
1.3.6.1.4.1.19011.1.3.1.1.2.3.3INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptConfigNtpIpAddress
OBJECT-TYPE
NTP IP address.
1.3.6.1.4.1.19011.1.3.1.1.2.3.4IpAddressread-writemandatory
inSeptConfigNtpTimeZone
OBJECT-TYPE
Enable/disable update date/time from NTP server.
1.3.6.1.4.1.19011.1.3.1.1.2.3.5INTEGER {gMT-1200(1), gMT-1100(2), gMT-1000(3), gMT-0900(4), gMT-0800(5), gMT-0700(6), gMT-0600(7), gMT-0500(8), gMT-0400(9), gMT-0330(10), gMT-0300(11), gMT-0200(12), gMT-0100(13), gMT-0000(14), gMT0100(15), gMT0200(16), gMT0300(17), gMT0330(18), gMT0400(19), gMT0500(20), gMT0530(21), gMT0600(22), gMT0700(23), gMT0800(24), gMT0900(25), gMT1000(26), gMT1100(27), gMT1200(28)}read-writemandatory
inSeptConfigDayLightSaving
OBJECT-TYPE
Enable/disable daylight saving for NTP time, if enabled, the time get from NTP will be set set one hour in advance to reflect daylight saving status.
1.3.6.1.4.1.19011.1.3.1.1.2.3.6INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptConfigLog
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.2.4
inSeptConfigHistoryLogFrequency
OBJECT-TYPE
The frequency of the update of the history log. The value is in seconds
1.3.6.1.4.1.19011.1.3.1.1.2.4.1INTEGER (5..3600)read-writemandatory
inSeptConfigExtHistoryLogFrequency
OBJECT-TYPE
The frequency of the update of the extended history log. The value is in seconds
1.3.6.1.4.1.19011.1.3.1.1.2.4.2INTEGER (1..1440)read-writemandatory
inSeptConfigConfigurationLog
OBJECT-TYPE
Enable/disable inSept to log parameter change.
1.3.6.1.4.1.19011.1.3.1.1.2.4.3INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptConfigDhcpStatue
OBJECT-TYPE
Enable or disable DHCP/BootP capability
1.3.6.1.4.1.19011.1.3.1.1.2.5INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptConfigPingStatue
OBJECT-TYPE
Enable or disable Ping Echo capability
1.3.6.1.4.1.19011.1.3.1.1.2.6INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptConfigTftpStatue
OBJECT-TYPE
Enable or disable TFTP network upgrade capability
1.3.6.1.4.1.19011.1.3.1.1.2.7INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptConfigTelnet
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.2.8
inSeptConfigTelnetStatue
OBJECT-TYPE
Enable or disable telnet access
1.3.6.1.4.1.19011.1.3.1.1.2.8.1INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptConfigTelnetPortNumber
OBJECT-TYPE
Setting the server port of telnet.
1.3.6.1.4.1.19011.1.3.1.1.2.8.2INTEGER (1..65535)read-writemandatory
inSeptConfigHttp
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.2.9
inSeptConfigHttpStatue
OBJECT-TYPE
Enable or disable HTTP access
1.3.6.1.4.1.19011.1.3.1.1.2.9.1INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptConfigHttpPortNumber
OBJECT-TYPE
Setting the server port of HTTP.
1.3.6.1.4.1.19011.1.3.1.1.2.9.2INTEGER (1..65535)read-writemandatory
inSeptConfigHttpSecurity
OBJECT-TYPE
Enable/disable HTTP access for read-only users
1.3.6.1.4.1.19011.1.3.1.1.2.9.3INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptConfigSnmp
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.2.10
inSeptConfigSnmpStatue
OBJECT-TYPE
Enable or disable SNMP access
1.3.6.1.4.1.19011.1.3.1.1.2.10.1INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptConfigSnmpPortNumber
OBJECT-TYPE
Setting the server port of SNMP.
1.3.6.1.4.1.19011.1.3.1.1.2.10.2INTEGER (1..65535)read-writemandatory
inSeptConfigControl
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.2.11
inSeptConfigResetToDefault
OBJECT-TYPE
Reset all parameters of interSeptor to default value
1.3.6.1.4.1.19011.1.3.1.1.2.11.1INTEGER {reset(1), nothing(2)}read-writemandatory
inSeptConfigRestart
OBJECT-TYPE
Restart interSeptor
1.3.6.1.4.1.19011.1.3.1.1.2.11.2INTEGER {restart(1), nothing(2)}read-writemandatory
inSeptConfigTrap
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.2.12
inSeptConfigTrapRetryCount
OBJECT-TYPE
The count of repeat traps to send to NMS before trap acknowledgement is received.
1.3.6.1.4.1.19011.1.3.1.1.2.12.1INTEGERread-writemandatory
inSeptConfigTrapRetryTime
OBJECT-TYPE
The time between retrying to send traps to NMS.
1.3.6.1.4.1.19011.1.3.1.1.2.12.2INTEGERread-writemandatory
inSeptConfigTrapAckSignature
OBJECT-TYPE
The signature of trap acknowledgement.
1.3.6.1.4.1.19011.1.3.1.1.2.12.3INTEGERread-writemandatory
inSeptConfigPollRate
OBJECT-TYPE
The frequency that interSeptor updates readings from sensors (unit : second).
1.3.6.1.4.1.19011.1.3.1.1.2.13INTEGER (3..60)read-writemandatory
inSeptConfigTrapsReceiversTable
OBJECT-TYPE
A list of managers to send traps to. The number of entries is given by the value of inSeptConfigNumTrapReceivers
1.3.6.1.4.1.19011.1.3.1.1.2.14not-accessiblemandatory
inSeptConfigTrapsReceiversEntry
OBJECT-TYPE
The managers to send traps to.
1.3.6.1.4.1.19011.1.3.1.1.2.14.1not-accessiblemandatory
inSepttrapsIndex
OBJECT-TYPE
The index to a trap receiver entry.
1.3.6.1.4.1.19011.1.3.1.1.2.14.1.1INTEGER (1..2147483647)read-onlymandatory
inSepttrapsReceiverAddr
OBJECT-TYPE
The IP address of the manager to send a trap to.
1.3.6.1.4.1.19011.1.3.1.1.2.14.1.2IpAddressread-writemandatory
inSeptreceiverCommunityString
OBJECT-TYPE
The community name to use in the trap when sent to the manager.
1.3.6.1.4.1.19011.1.3.1.1.2.14.1.3DisplayString (SIZE(0..19))read-writemandatory
inSeptreceiverSeverityLevel
OBJECT-TYPE
The severity level of traps to be received by this manager.
1.3.6.1.4.1.19011.1.3.1.1.2.14.1.4INTEGER {informational(1), warning(2), severe(3)}read-writemandatory
inSeptreceiverDescription
OBJECT-TYPE
Description of trap receivers
1.3.6.1.4.1.19011.1.3.1.1.2.14.1.5DisplayString (SIZE(0..31))read-writemandatory
inSeptConfigAccessControlTable
OBJECT-TYPE
A list of managers which can access interSeptor with private community string.
1.3.6.1.4.1.19011.1.3.1.1.2.15not-accessiblemandatory
inSeptConfigAccessControlEntry
OBJECT-TYPE
The managers.
1.3.6.1.4.1.19011.1.3.1.1.2.15.1not-accessiblemandatory
accessIndex
OBJECT-TYPE
The index to a access control entry.
1.3.6.1.4.1.19011.1.3.1.1.2.15.1.1INTEGER (1..2147483647)read-onlymandatory
accessControlAddr
OBJECT-TYPE
The IP address of the manager to access interSeptor
1.3.6.1.4.1.19011.1.3.1.1.2.15.1.2IpAddressread-writemandatory
accessCommunityString
OBJECT-TYPE
The community name to use in the manager when access interSeptor
1.3.6.1.4.1.19011.1.3.1.1.2.15.1.3DisplayString (SIZE(0..19))read-writemandatory
accessControlMode
OBJECT-TYPE
Access type, only read/Write access type can change parameter of interSeptor
1.3.6.1.4.1.19011.1.3.1.1.2.15.1.4INTEGER {readOnly(1), read-write(2), notAccess(3)}read-writemandatory
inSeptConfigTemperatureUnit
OBJECT-TYPE
The temperature unit of the system, can be Celsius or Farenheit
1.3.6.1.4.1.19011.1.3.1.1.2.16INTEGER {celsius(1), fahrenheit(2)}read-writemandatory
inSeptConfigDateFormat
OBJECT-TYPE
The date format of the system, can be dd/mm/yyyy or mm/dd/yyyy
1.3.6.1.4.1.19011.1.3.1.1.2.17INTEGER {dd-mm-yyyy(1), mm-dd-yyyy(2)}read-writemandatory
inSeptsensorMonitor
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.3
inSeptsensorMonitorSensorNumber
OBJECT-TYPE
The number of sensors that can be monitored.
1.3.6.1.4.1.19011.1.3.1.1.3.1INTEGERread-onlymandatory
inSeptsensorMonitorSensorTable
OBJECT-TYPE
A list of sensor devices to be monitored.
1.3.6.1.4.1.19011.1.3.1.1.3.2not-accessiblemandatory
inSeptsensorMonitorSensorEntry
OBJECT-TYPE
The sensor device.
1.3.6.1.4.1.19011.1.3.1.1.3.2.1not-accessiblemandatory
inSeptsensorMonitorDeviceIndex
OBJECT-TYPE
The index to a sensor device entry.
1.3.6.1.4.1.19011.1.3.1.1.3.2.1.1INTEGER (1..2147483647)read-onlymandatory
inSeptsensorMonitorDeviceStatus
OBJECT-TYPE
The device type connected to interSeptor.
1.3.6.1.4.1.19011.1.3.1.1.3.2.1.2INTEGER {unknown(1), disabled(2), eMD-HT(3), eMD-T(4)}read-onlymandatory
inSeptsensorMonitorDeviceTemperature
OBJECT-TYPE
The temperature of sensor on device interSeptor, the unit is 0.1 degree.
1.3.6.1.4.1.19011.1.3.1.1.3.2.1.3INTEGERread-onlymandatory
inSeptsensorMonitorDeviceTemperatureAlarm
OBJECT-TYPE
The alarm type of sensor on device interSeptor.
1.3.6.1.4.1.19011.1.3.1.1.3.2.1.4INTEGER {unknown(1), disabled(2), normal(3), lowWarning(4), lowCritical(5), highWarning(6), highCritical(7)}read-onlymandatory
inSeptsensorMonitorDeviceHumidity
OBJECT-TYPE
The humidity of sensor on device interSeptor, the unit is 0.1%.
1.3.6.1.4.1.19011.1.3.1.1.3.2.1.5INTEGERread-onlymandatory
inSeptsensorMonitorDeviceHumidityAlarm
OBJECT-TYPE
The alarm type of sensor on device interSeptor.
1.3.6.1.4.1.19011.1.3.1.1.3.2.1.6INTEGER {unknown(1), disabled(2), normal(3), lowWarning(4), lowCritical(5), highWarning(6), highCritical(7)}read-onlymandatory
inSeptsensorMonitorAlarm1
OBJECT-TYPE
The device status of sensor 1 connected to interSeptor.
1.3.6.1.4.1.19011.1.3.1.1.3.2.1.7INTEGER {unknown(1), disabled(2), active(3), inactive(4)}read-onlymandatory
inSeptsensorMonitorAlarm2
OBJECT-TYPE
The device status of sensor 2 connected to interSeptor.
1.3.6.1.4.1.19011.1.3.1.1.3.2.1.8INTEGER {unknown(1), disabled(2), active(3), inactive(4)}read-onlymandatory
inSeptsensorConfig
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.4
inSeptsensorConfigSensorNumber
OBJECT-TYPE
The number of sensors that are connected to interSeptor.
1.3.6.1.4.1.19011.1.3.1.1.4.1INTEGERread-onlymandatory
inSeptsensorConfigSensorTable
OBJECT-TYPE
A list of sensor devices to be configured.
1.3.6.1.4.1.19011.1.3.1.1.4.2not-accessiblemandatory
inSeptsensorConfigSensorEntry
OBJECT-TYPE
The sensor device.
1.3.6.1.4.1.19011.1.3.1.1.4.2.1not-accessiblemandatory
inSeptsensorConfigDeviceIndex
OBJECT-TYPE
The index to a sensor device entry.
1.3.6.1.4.1.19011.1.3.1.1.4.2.1.1INTEGER (1..2147483647)read-onlymandatory
inSeptsensorConfigDeviceName
OBJECT-TYPE
The name of the sensor device for identification.
1.3.6.1.4.1.19011.1.3.1.1.4.2.1.2DisplayString (SIZE(0..15))read-writemandatory
inSeptsensorConfigDeviceState
OBJECT-TYPE
The setup of sensor device type.
1.3.6.1.4.1.19011.1.3.1.1.4.2.1.3INTEGER {disabled(1), auto(2)}read-writemandatory
inSeptsensorConfigSensor1
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.4.3
inSeptsensorConfigSensor1DeviceName
OBJECT-TYPE
The name of sensor device.
1.3.6.1.4.1.19011.1.3.1.1.4.3.1DisplayString (SIZE(0..15))read-writemandatory
inSeptsensorConfigSensor1DeviceState
OBJECT-TYPE
The setup of sensor device type.
1.3.6.1.4.1.19011.1.3.1.1.4.3.2INTEGER {disabled(1), auto(2)}read-writemandatory
inSeptsensorConfigSensor1Temperature
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.4.3.3
inSeptsensorConfigSensor1TemperatureName
OBJECT-TYPE
The temperature sensor name.
1.3.6.1.4.1.19011.1.3.1.1.4.3.3.1DisplayString (SIZE(0..15))read-writemandatory
inSeptsensorConfigSensor1TemperatureLowWarning
OBJECT-TYPE
The set point to trigger low warning alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.3.2INTEGERread-writemandatory
inSeptsensorConfigSensor1TemperatureLowCritical
OBJECT-TYPE
The threshold to trigger low critical alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.3.3INTEGERread-writemandatory
inSeptsensorConfigSensor1TemperatureHighWarning
OBJECT-TYPE
The threshold to trigger high warning alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.3.4INTEGERread-writemandatory
inSeptsensorConfigSensor1TemperatureHighCritical
OBJECT-TYPE
The threshold to trigger high critical alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.3.5INTEGERread-writemandatory
inSeptsensorConfigSensor1TemperatureHysteresis
OBJECT-TYPE
The set value to prevent too many alarms when temperature is hovering around the set threshold.
1.3.6.1.4.1.19011.1.3.1.1.4.3.3.6INTEGERread-writemandatory
inSeptsensorConfigSensor1TemperatureCalibration
OBJECT-TYPE
The set value to get the correct temperature according to your reference temperature.
1.3.6.1.4.1.19011.1.3.1.1.4.3.3.7INTEGER {temperatureIncrease0Point0(1), temperatureIncrease0Point5(2), temperatureIncrease1Point0(3), temperatureIncrease1Point5(4), temperatureIncrease2Point0(5), temperatureIncrease2Point5(6), temperatureIncrease3Point0(7), temperatureMinus0Point5(8), temperatureMinus1Point0(9), temperatureMinus1Point5(10), temperatureMinus2Point0(11), temperatureMinus2Point5(12), temperatureMinusPoint0(13)}read-writemandatory
inSeptsensorConfigSensor1TemperatureLowWarningStatus
OBJECT-TYPE
Enable/disable the set point to trigger low warning alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.3.8INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptsensorConfigSensor1TemperatureLowCriticalStatus
OBJECT-TYPE
Enable/disable the set point to trigger low critical alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.3.9INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptsensorConfigSensor1TemperatureHighWarningStatus
OBJECT-TYPE
Enable/disable the set point to trigger high warning alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.3.10INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptsensorConfigSensor1TemperatureHighCriticalStatus
OBJECT-TYPE
Enable/disable the set point to trigger high critical alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.3.11INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptsensorConfigSensor1Humidity
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.4.3.4
inSeptsensorConfigSensor1HumdityName
OBJECT-TYPE
The humidity sensor name.
1.3.6.1.4.1.19011.1.3.1.1.4.3.4.1DisplayString (SIZE(0..15))read-writemandatory
inSeptsensorConfigSensor1HumidityLowWarning
OBJECT-TYPE
The set point to trigger low warning alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.4.2INTEGERread-writemandatory
inSeptsensorConfigSensor1HumidityLowCritical
OBJECT-TYPE
The threshole to trigger low critical alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.4.3INTEGERread-writemandatory
inSeptsensorConfigSensor1HumidityHighWarning
OBJECT-TYPE
The threshold to trigger high warning alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.4.4INTEGERread-writemandatory
inSeptsensorConfigSensor1HumidityHighCritical
OBJECT-TYPE
The threshold to trigger high critical alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.4.5INTEGERread-writemandatory
inSeptsensorConfigSensor1HumidityHysteresis
OBJECT-TYPE
The set value to prevent too many alarms when Humidity is hovering around the set threshold.
1.3.6.1.4.1.19011.1.3.1.1.4.3.4.6INTEGERread-writemandatory
inSeptsensorConfigSensor1HumidityCalibration
OBJECT-TYPE
The set value to get the correct temperature according to your reference temperature.
1.3.6.1.4.1.19011.1.3.1.1.4.3.4.7INTEGER {humidityIncrease0Point0(1), humidityIncrease1Point0(2), humidityIncrease2Point0(3), humidityIncrease3Point0(4), humidityIncrease4Point0(5), humidityIncrease5Point0(6), humidityIncrease6Point0(7), humidityMinus1Point0(8), humidityMinus2Point0(9), humidityMinus3Point0(10), humidityMinus4Point0(11), humidityMinus5Point0(12), humidityMinus6Point0(13)}read-writemandatory
inSeptsensorConfigSensor1HumidityLowWarningStatus
OBJECT-TYPE
Enable/disable the set point to trigger low warning alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.4.8INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptsensorConfigSensor1HumidityLowCriticalStatus
OBJECT-TYPE
Enable/disable the set point to trigger low critical alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.4.9INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptsensorConfigSensor1HumidityHighWarningStatus
OBJECT-TYPE
Enable/disable the set point to trigger high warning alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.4.10INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptsensorConfigSensor1HumidityHighCriticalStatus
OBJECT-TYPE
Enable/disable the set point to trigger high critical alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.4.11INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptsensorConfigSensor1Alarm1
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.4.3.5
inSeptsensorConfigSensor1Alarm1Name
OBJECT-TYPE
The name of alarm-1.
1.3.6.1.4.1.19011.1.3.1.1.4.3.5.1DisplayString (SIZE(0..15))read-writemandatory
inSeptsensorConfigSensor1Alarm1State
OBJECT-TYPE
Setup the signal type to trigger alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.5.2INTEGER {disabled(1), normalOpen(2), normalClose(3), highActive(4), lowActive(5)}read-writemandatory
inSeptsensorConfigSensor1Alarm1Hysteresis
OBJECT-TYPE
The set value to delay the alarm triggered when event occurs.
1.3.6.1.4.1.19011.1.3.1.1.4.3.5.3INTEGERread-writemandatory
inSeptsensorConfigSensor1Alarm2
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.4.3.6
inSeptsensorConfigSensor1Alarm2Name
OBJECT-TYPE
The name of alarm-1.
1.3.6.1.4.1.19011.1.3.1.1.4.3.6.1DisplayString (SIZE(0..15))read-writemandatory
inSeptsensorConfigSensor1Alarm2State
OBJECT-TYPE
Setup the signal type to trigger alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.3.6.2INTEGER {disabled(1), normalOpen(2), normalClose(3), highActive(4), lowActive(5)}read-writemandatory
inSeptsensorConfigSensor1Alarm2Hysteresis
OBJECT-TYPE
The set value to delay the alarm triggered when event occurs.
1.3.6.1.4.1.19011.1.3.1.1.4.3.6.3INTEGERread-writemandatory
inSeptsensorConfigSensor2
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.4.4
inSeptsensorConfigSensor2DeviceName
OBJECT-TYPE
The name of sensor device.
1.3.6.1.4.1.19011.1.3.1.1.4.4.1DisplayString (SIZE(0..15))read-writemandatory
inSeptsensorConfigSensor2DeviceState
OBJECT-TYPE
The setup of sensor device type.
1.3.6.1.4.1.19011.1.3.1.1.4.4.2INTEGER {disabled(1), auto(2)}read-writemandatory
inSeptsensorConfigSensor2Temperature
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.4.4.3
inSeptsensorConfigSensor2TemperatureName
OBJECT-TYPE
The temperature sensor name.
1.3.6.1.4.1.19011.1.3.1.1.4.4.3.1DisplayString (SIZE(0..15))read-writemandatory
inSeptsensorConfigSensor2TemperatureLowWarning
OBJECT-TYPE
The set point to trigger low warning alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.3.2INTEGERread-writemandatory
inSeptsensorConfigSensor2TemperatureLowCritical
OBJECT-TYPE
The threshold to trigger low critical alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.3.3INTEGERread-writemandatory
inSeptsensorConfigSensor2TemperatureHighWarning
OBJECT-TYPE
The threshold to trigger high warning alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.3.4INTEGERread-writemandatory
inSeptsensorConfigSensor2TemperatureHighCritical
OBJECT-TYPE
The threshold to trigger high critical alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.3.5INTEGERread-writemandatory
inSeptsensorConfigSensor2TemperatureHysteresis
OBJECT-TYPE
The set value to prevent too many alarms when temperature is hovering around the set threshold.
1.3.6.1.4.1.19011.1.3.1.1.4.4.3.6INTEGERread-writemandatory
inSeptsensorConfigSensor2TemperatureCalibration
OBJECT-TYPE
The set value to get the correct temperature according to your reference temperature.
1.3.6.1.4.1.19011.1.3.1.1.4.4.3.7INTEGER {temperatureIncrease0Point0(1), temperatureIncrease0Point5(2), temperatureIncrease1Point0(3), temperatureIncrease1Point5(4), temperatureIncrease2Point0(5), temperatureIncrease2Point5(6), temperatureIncrease3Point0(7), temperatureMinus0Point5(8), temperatureMinus1Point0(9), temperatureMinus1Point5(10), temperatureMinus2Point0(11), temperatureMinus2Point5(12), temperatureMinusPoint0(13)}read-writemandatory
inSeptsensorConfigSensor2TemperatureLowWarningStatus
OBJECT-TYPE
Enable/disable the set point to trigger low warning alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.3.8INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptsensorConfigSensor2TemperatureLowCriticalStatus
OBJECT-TYPE
Enable/disable the set point to trigger low critical alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.3.9INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptsensorConfigSensor2TemperatureHighWarningStatus
OBJECT-TYPE
Enable/disable the set point to trigger high warning alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.3.10INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptsensorConfigSensor2TemperatureHighCriticalStatus
OBJECT-TYPE
Enable/disable the set point to trigger high critical alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.3.11INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptsensorConfigSensor2Humidity
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.4.4.4
inSeptsensorConfigSensor2HumdityName
OBJECT-TYPE
The humidity sensor name.
1.3.6.1.4.1.19011.1.3.1.1.4.4.4.1DisplayString (SIZE(0..15))read-writemandatory
inSeptsensorConfigSensor2HumidityLowWarning
OBJECT-TYPE
The set point to trigger low warning alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.4.2INTEGERread-writemandatory
inSeptsensorConfigSensor2HumidityLowCritical
OBJECT-TYPE
The threshold to trigger low critical alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.4.3INTEGERread-writemandatory
inSeptsensorConfigSensor2HumidityHighWarning
OBJECT-TYPE
The threshold to trigger high warning alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.4.4INTEGERread-writemandatory
inSeptsensorConfigSensor2HumidityHighCritical
OBJECT-TYPE
The threshold to trigger high critical alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.4.5INTEGERread-writemandatory
inSeptsensorConfigSensor2HumidityHysteresis
OBJECT-TYPE
The set value to prevent too many alarms when Humidity is hovering around the set threshold.
1.3.6.1.4.1.19011.1.3.1.1.4.4.4.6INTEGERread-writemandatory
inSeptsensorConfigSensor2HumidityCalibration
OBJECT-TYPE
The set value to get the correct temperature according to your reference temperature.
1.3.6.1.4.1.19011.1.3.1.1.4.4.4.7INTEGER {humidityIncrease0Point0(1), humidityIncrease1Point0(2), humidityIncrease2Point0(3), humidityIncrease3Point0(4), humidityIncrease4Point0(5), humidityIncrease5Point0(6), humidityIncrease6Point0(7), humidityMinus1Point0(8), humidityMinus2Point0(9), humidityMinus3Point0(10), humidityMinus4Point0(11), humidityMinus5Point0(12), humidityMinus6Point0(13)}read-writemandatory
inSeptsensorConfigSensor2HumidityLowWarningStatus
OBJECT-TYPE
Enable/disable the set point to trigger low warning alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.4.8INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptsensorConfigSensor2HumidityLowCriticalStatus
OBJECT-TYPE
Enable/disable the set point to trigger low critical alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.4.9INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptsensorConfigSensor2HumidityHighWarningStatus
OBJECT-TYPE
Enable/disable the set point to trigger high warning alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.4.10INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptsensorConfigSensor2HumidityHighCriticalStatus
OBJECT-TYPE
Enable/disable the set point to trigger high critical alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.4.11INTEGER {enabled(1), disabled(2)}read-writemandatory
inSeptsensorConfigSensor2Alarm1
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.4.4.5
inSeptsensorConfigSensor2Alarm1Name
OBJECT-TYPE
The name of alarm-1.
1.3.6.1.4.1.19011.1.3.1.1.4.4.5.1DisplayString (SIZE(0..15))read-writemandatory
inSeptsensorConfigSensor2Alarm1State
OBJECT-TYPE
Setup the signal type to trigger alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.5.2INTEGER {disabled(1), normalOpen(2), normalClose(3), highActive(4), lowActive(5)}read-writemandatory
inSeptsensorConfigSensor2Alarm1Hysteresis
OBJECT-TYPE
The set value to delay the alarm triggered when event occurs.
1.3.6.1.4.1.19011.1.3.1.1.4.4.5.3INTEGERread-writemandatory
inSeptsensorConfigSensor2Alarm2
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.1.4.4.6
inSeptsensorConfigSensor2Alarm2Name
OBJECT-TYPE
The name of alarm-1.
1.3.6.1.4.1.19011.1.3.1.1.4.4.6.1DisplayString (SIZE(0..15))read-writemandatory
inSeptsensorConfigSensor2Alarm2State
OBJECT-TYPE
Setup the signal type to trigger alarm.
1.3.6.1.4.1.19011.1.3.1.1.4.4.6.2INTEGER {disabled(1), normalOpen(2), normalClose(3), highActive(4), lowActive(5)}read-writemandatory
inSeptsensorConfigSensor2Alarm2Hysteresis
OBJECT-TYPE
The set value to delay the alarm triggered when event occurs.
1.3.6.1.4.1.19011.1.3.1.1.4.4.6.3INTEGERread-writemandatory
inSeptTraps
OBJECT-IDENTITY
1.3.6.1.4.1.19011.1.3.1.2

Notifications

NameOIDStatus
inSeptCommunicationRestored
NOTIFICATION-TYPE
INFORMATION: Communication between interSeptor and sensor has been established.
1.3.6.1.4.1.19011.1.3.1.2.0.1
inSeptCommunicationLost
NOTIFICATION-TYPE
WARNING: Communication between interSeptor and sensor has been lost.
1.3.6.1.4.1.19011.1.3.1.2.0.2
inSeptAlarm1Inactive
NOTIFICATION-TYPE
INFORMATION: Alarm1 of sensor has returned from active state.
1.3.6.1.4.1.19011.1.3.1.2.0.3
inSeptAlarm1Active
NOTIFICATION-TYPE
WARNING: Alarm1 has become active.
1.3.6.1.4.1.19011.1.3.1.2.0.4
inSeptAlarm2Inactive
NOTIFICATION-TYPE
INFORMATION: Alarm2 of sensor has returned from active state.
1.3.6.1.4.1.19011.1.3.1.2.0.5
inSeptAlarm2Active
NOTIFICATION-TYPE
WARNING: Alarm2 has become active.
1.3.6.1.4.1.19011.1.3.1.2.0.6
inSeptTemperatureNotHighWarning
NOTIFICATION-TYPE
INFORMATION: The temperature of sensor has returned from High warning to normal.
1.3.6.1.4.1.19011.1.3.1.2.0.7
inSeptTemperatureHighWarning
NOTIFICATION-TYPE
WARNING: The temperature of sensor is higher than High warning set point.
1.3.6.1.4.1.19011.1.3.1.2.0.8
inSeptTemperatureNotLowWarning
NOTIFICATION-TYPE
INFORMATION: The temperature of sensor has returned from low warning to normal.
1.3.6.1.4.1.19011.1.3.1.2.0.9
inSeptTemperatureLowWarning
NOTIFICATION-TYPE
WARNING: The temperature of sensor is lower than low warning set point.
1.3.6.1.4.1.19011.1.3.1.2.0.10
inSeptTemperatureNotHighCritical
NOTIFICATION-TYPE
INFORMATION: The temperature of sensor is lower than high critical set point.
1.3.6.1.4.1.19011.1.3.1.2.0.11
inSeptTemperatureHighCritical
NOTIFICATION-TYPE
CRITICAL: The temperature of sensor is higher than high critical set point.
1.3.6.1.4.1.19011.1.3.1.2.0.12
inSeptTemperatureNotLowCritical
NOTIFICATION-TYPE
INFORMATION: The temperature of sensor is higher than low critical set point.
1.3.6.1.4.1.19011.1.3.1.2.0.13
inSeptTemperatureLowCritical
NOTIFICATION-TYPE
CRITICAL: The temperature of sensor is lower than low critical set point.
1.3.6.1.4.1.19011.1.3.1.2.0.14
inSeptHumidityNotHighWarning
NOTIFICATION-TYPE
INFORMATION: The humidity of sensor has returned from High warning to normal.
1.3.6.1.4.1.19011.1.3.1.2.0.15
inSeptHumidityHighWarning
NOTIFICATION-TYPE
WARNING: The humidity of sensor is higher than High warning set point.
1.3.6.1.4.1.19011.1.3.1.2.0.16
inSeptHumidityNotLowWarning
NOTIFICATION-TYPE
INFORMATION: The humidity of sensor has returned from low warning to normal.
1.3.6.1.4.1.19011.1.3.1.2.0.17
inSeptHumidityLowWarning
NOTIFICATION-TYPE
WARNING: The humidity of sensor is lower than low warning set point.
1.3.6.1.4.1.19011.1.3.1.2.0.18
inSeptHumidityNotHighCritical
NOTIFICATION-TYPE
INFORMATION: The humidity of sensor is lower than high critical set point.
1.3.6.1.4.1.19011.1.3.1.2.0.19
inSeptHumidityHighCritical
NOTIFICATION-TYPE
CRITICAL: The humidity of sensor is higher than high critical set point.
1.3.6.1.4.1.19011.1.3.1.2.0.20
inSeptHumidityNotLowCritical
NOTIFICATION-TYPE
INFORMATION: The humidity of sensor is higher than low critical set point.
1.3.6.1.4.1.19011.1.3.1.2.0.21
inSeptHumidityLowCritical
NOTIFICATION-TYPE
CRITICAL: The humidity of sensor is lower than low critical set point.
1.3.6.1.4.1.19011.1.3.1.2.0.22