MIBs Depot

ISILON-TRAP-MIB

Registered at
1.3.6.1.4.1.12124.250
Last updated
2015-12-18 00:00
Organization
Isilon Systems LLC
Revisions
2015-04-08 00:00, 2013-06-21 00:00, 2013-03-21 00:00, 2012-09-21 00:00, 2012-08-01 00:00, 2012-05-23 00:00, 2012-04-30 00:00, 2011-09-29 00:00, 2009-11-12 00:00, 2009-11-10 00:00
Namespace
emc
Source file
ISILON-TRAP-MIB
Digest
sha256:8b5785fa4a5cf538ef31fb2867d7a21682f106cecbfeeebb43cd0a8ee583f7f9

Description

Traps for Isilon Systems OneFS operating system.

Contact

Isilon Systems LLC Support phone: 1-800.782.4362 Support website: http://support.emc.com

Imports

FromSymbols
ISILON-MIBisilon
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter64, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

HCNUM-TC
ISILON-MIB
ISILON-TRAP-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
groupStateTraps
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.10
nodeStatus
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.10.1
nodeExpStatus
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.10.2
nodeShutdown
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.10.3
nodeShutdownFail
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.10.4
nodeRebootCoalesced
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.10.20
nodeStatusCoalescing
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.10.21
filesystemTraps
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.11
partitionUsage
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.11.1
clusterStorageUsage
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.11.2
filesysError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.11.3
diskPoolUsage
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.11.4
diskPoolOldDbVersion
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.11.5
ssdUsage
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.11.6
filesysCoalesce
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.11.20
smartQuotaTraps
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.12
quotaThreshError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.12.1
quotaNotifyError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.12.2
quotaError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.12.3
snapshotTraps
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.13
snapshotError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.13.1
snapshotReserve
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.13.2
syncIQTraps
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.14
siqEvent
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.14.1
siqError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.14.2
siqPolicyCoalesced
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.14.20
siqTargetCoalesced
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.14.21
softwareTraps
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.15
jobEngineError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.15.1
flexProtectRunning
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.15.2
avscanInfectedFile
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.15.3
mcpProcFailed
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.15.5
mcpProcKilled
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.15.6
licenseExpiration
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.15.7
firmwareUpdateIncomplete
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.15.8
testEvent
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.15.9
nodeCPU
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.15.10
mountdClientMountFailed
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.15.11
mountdHostLookupFailed
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.15.12
mixedSedNonSedCluster
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.15.13
nfsCookieTranslationFailed
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.15.15
avscanTraps
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.16
avscanNoServersConf
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.16.1
avscanError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.16.2
avscanCoalesced
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.16.20
netProtoTraps
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.17
clockSkew
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.17.1
sharePermsUpgradeFail
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.17.2
winTimeConnectivityLost
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.17.3
winNetMapFull
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.17.4
winNetAuth
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.17.5
lwioParam
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.17.6
winSmbUpgrade
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.17.7
winNetworkCoalesce
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.17.20
winIDmapCoalesce
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.17.21
winAuthCoalesce
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.17.22
winAuthUpgrade
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.17.23
networkingTraps
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.18
netStatus
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.18.1
netStatusCoalescing
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.18.20
hardwareTraps
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.19
hardwareError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.19.1
hardwareErrorMsg
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.19.1.1
hwError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.19.2
diskNodeOffline
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.19.10
hardwareCoalesced
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.19.20
sensorCoalesced
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.19.50
fanCoalesced
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.19.51
tempCoalesced
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.19.52
voltsCoalesced
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.19.53
systemDiskTraps
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.20
driveStatus
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.20.1
bootDiskFail
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.20.2
diskError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.20.3
bootDiskMirrorReqMissing
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.20.4
diskErrorCoalesced
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.20.20
sensorTraps
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21
hwPwrSupply
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.1
hwPwrSupplyOver
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.1.1
hwPwrSupplyUnder
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.1.2
hwFan
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.2
hwFanOver
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.2.1
hwFanUnder
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.2.2
hwVoltage
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.10
hwVoltageOver
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.10.1
hwVoltageUnder
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.10.2
hwTemp
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.11
hwTempOver
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.11.1
hwTempUnder
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.11.2
hwPower
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.12
hwMem
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.13
hwCpuThrottle
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.14
sensorMonitor
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.15
hwCurrent
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.16
hwCurrentOver
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.16.1
hwCurrentUnder
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.21.16.2
storageTransportTraps
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.22
sasPhyError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.22.1
storageTransportCoalesced
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.22.2
cloudPoolsTraps
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.23
cloudpoolNetworkError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.23.1
cloudpoolAuthenticationError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.23.2
cloudpoolAuthorizationError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.23.3
cloudpoolBucketNotFoundError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.23.4
cloudpoolObjectNotFoundError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.23.5
cloudpoolDataCorruptionIntegrityError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.23.6
cloudpoolNoUsableAccountFoundError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.23.7
cloudpoolCertificateError
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.23.8
upgradeTraps
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.24
upgradeStart
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.24.1
upgradeFinish
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.24.2
upgradeClusterEvent
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.24.3
upgradeNodeEvent
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.24.4
upgradeRollbackStart
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.24.5
variables
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.50
nodeIdentifier
OBJECT-TYPE
The Logical Node Number of the node referenced in the notification.
1.3.6.1.4.1.12124.250.50.1Integer32accessible-for-notifycurrent
measuredValue
OBJECT-TYPE
The measured value that triggered the event
1.3.6.1.4.1.12124.250.50.2Integer32accessible-for-notifycurrent
units
OBJECT-TYPE
The units of the measurement
1.3.6.1.4.1.12124.250.50.3OCTET STRINGaccessible-for-notifycurrent
oid
OBJECT-TYPE
The OID of the sensor reporting a problem
1.3.6.1.4.1.12124.250.50.4OBJECT IDENTIFIERaccessible-for-notifycurrent
bay
OBJECT-TYPE
Drive bay number
1.3.6.1.4.1.12124.250.50.5Integer32accessible-for-notifycurrent
ifName
OBJECT-TYPE
Interface name
1.3.6.1.4.1.12124.250.50.6OCTET STRINGaccessible-for-notifycurrent
phy
OBJECT-TYPE
PHY connection
1.3.6.1.4.1.12124.250.50.7Integer32accessible-for-notifycurrent
errorMessage
OBJECT-TYPE
Error message
1.3.6.1.4.1.12124.250.50.8OCTET STRINGaccessible-for-notifycurrent
errno
OBJECT-TYPE
Error number
1.3.6.1.4.1.12124.250.50.9Integer32accessible-for-notifycurrent
stringArg
OBJECT-TYPE
A trap-related string argument.
1.3.6.1.4.1.12124.250.50.10OCTET STRINGaccessible-for-notifycurrent
message
OBJECT-TYPE
A trap-related message string.
1.3.6.1.4.1.12124.250.50.11OCTET STRINGaccessible-for-notifycurrent
i64Arg
OBJECT-TYPE
Error number
1.3.6.1.4.1.12124.250.50.12Counter64accessible-for-notifycurrent
i32Arg
OBJECT-TYPE
Integer argument
1.3.6.1.4.1.12124.250.50.13Integer32accessible-for-notifycurrent
measuredValueStr
OBJECT-TYPE
The measured value that triggered the event represented as string
1.3.6.1.4.1.12124.250.50.14OCTET STRINGaccessible-for-notifycurrent
instanceIdentifier
OBJECT-TYPE
Instance ID of event generating the trap
1.3.6.1.4.1.12124.250.50.15OCTET STRINGaccessible-for-notifycurrent
deviceIdentifier
OBJECT-TYPE
The Device Node Number of the node referenced in the notification.
1.3.6.1.4.1.12124.250.50.16Integer32accessible-for-notifycurrent
trapConformance
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.51
trapCompliance
OBJECT-IDENTITY
1.3.6.1.4.1.12124.250.52

Notifications

NameOIDStatus
nodeStatusCrit
NOTIFICATION-TYPE
A critical node status event has occurred.
1.3.6.1.4.1.12124.250.10.1.3current
nodeStatusInfo
NOTIFICATION-TYPE
A node status event has occurred.
1.3.6.1.4.1.12124.250.10.1.7current
nodeExpStatusCrit
NOTIFICATION-TYPE
A disk-only node has gone offline and cannot be contacted by the cluster.
1.3.6.1.4.1.12124.250.10.2.3current
nodeShutdownInfo
NOTIFICATION-TYPE
A node is being shut down or rebooted.
1.3.6.1.4.1.12124.250.10.3.7current
nodeShutdownFailCrit
NOTIFICATION-TYPE
Shut down or reboot failed for a node.
1.3.6.1.4.1.12124.250.10.4.3current
nodeRebootCoalescedInfo
NOTIFICATION-TYPE
A node is being rebooted.
1.3.6.1.4.1.12124.250.10.20.7current
nodeStatusCoalescingCrit
NOTIFICATION-TYPE
Critical node status events are occurring
1.3.6.1.4.1.12124.250.10.21.3current
nodeStatusCoalescingWarn
NOTIFICATION-TYPE
Warning node status events are occurring
1.3.6.1.4.1.12124.250.10.21.5current
partitionUsageCrit
NOTIFICATION-TYPE
A partition is over the critical threshold percentage.
1.3.6.1.4.1.12124.250.11.1.3current
partitionUsageWarn
NOTIFICATION-TYPE
A partition is over the warning threshold percentage.
1.3.6.1.4.1.12124.250.11.1.5current
partitionUsageInfo
NOTIFICATION-TYPE
A partition is over the info threshold percentage.
1.3.6.1.4.1.12124.250.11.1.7current
clusterStorageUsageCrit
NOTIFICATION-TYPE
The /ifs partition is near capacity.
1.3.6.1.4.1.12124.250.11.2.3current
clusterStorageUsageWarn
NOTIFICATION-TYPE
The /ifs partition is near capacity.
1.3.6.1.4.1.12124.250.11.2.5current
filesysErrorCrit
NOTIFICATION-TYPE
A critical /ifs filesystem error has occurred
1.3.6.1.4.1.12124.250.11.3.3current
filesysErrorWarn
NOTIFICATION-TYPE
A warning-level /ifs filesystem error has occurred
1.3.6.1.4.1.12124.250.11.3.5current
filesysErrorInfo
NOTIFICATION-TYPE
An /ifs filesystem error has occurred.
1.3.6.1.4.1.12124.250.11.3.7current
diskPoolUsageCrit
NOTIFICATION-TYPE
A disk pool is near capacity.
1.3.6.1.4.1.12124.250.11.4.3current
diskPoolUsageWarn
NOTIFICATION-TYPE
A disk pool is near capacity.
1.3.6.1.4.1.12124.250.11.4.5current
diskPoolOldDbVersionWarn
NOTIFICATION-TYPE
The SmartPools upgrade has not completed.
1.3.6.1.4.1.12124.250.11.5.5current
ssdUsageCrit
NOTIFICATION-TYPE
The SSD drives are at capacity.
1.3.6.1.4.1.12124.250.11.6.1current
ssdUsageWarn
NOTIFICATION-TYPE
The SSD drives are near capacity.
1.3.6.1.4.1.12124.250.11.6.2current
ssdUsageInfo
NOTIFICATION-TYPE
The SSD drives are near capacity.
1.3.6.1.4.1.12124.250.11.6.3current
filesysCoalesceCrit
NOTIFICATION-TYPE
Filesystem issues are occurring at a critical level
1.3.6.1.4.1.12124.250.11.20.3current
filesysCoalesceWarn
NOTIFICATION-TYPE
Filesystem issues are occurring at a warning level
1.3.6.1.4.1.12124.250.11.20.5current
quotaThreshErrorInfo
NOTIFICATION-TYPE
SmartQuotas threshold violation
1.3.6.1.4.1.12124.250.12.1.7current
quotaNotifyErrorWarn
NOTIFICATION-TYPE
SmartQuotas threshold notification failed
1.3.6.1.4.1.12124.250.12.2.5current
quotaErrorWarn
NOTIFICATION-TYPE
SmartQuotas error
1.3.6.1.4.1.12124.250.12.3.5current
snapshotErrorWarn
NOTIFICATION-TYPE
Snapshot error
1.3.6.1.4.1.12124.250.13.1.5current
snapshotReserveCrit
NOTIFICATION-TYPE
Snapshot reserve space is over its critical limit
1.3.6.1.4.1.12124.250.13.2.3current
snapshotReserveWarn
NOTIFICATION-TYPE
Snapshot reserve space is over its warning limit
1.3.6.1.4.1.12124.250.13.2.5current
siqEventCrit
NOTIFICATION-TYPE
SyncIQ event
1.3.6.1.4.1.12124.250.14.1.3current
siqEventWarn
NOTIFICATION-TYPE
SyncIQ event
1.3.6.1.4.1.12124.250.14.1.5current
siqErrorWarn
NOTIFICATION-TYPE
SyncIQ error
1.3.6.1.4.1.12124.250.14.2.5current
siqPolicyCoalescedCrit
NOTIFICATION-TYPE
SyncIQ policy errors are occurring
1.3.6.1.4.1.12124.250.14.20.3current
siqPolicyCoalescedWarn
NOTIFICATION-TYPE
SyncIQ policy errors are occurring
1.3.6.1.4.1.12124.250.14.20.5current
siqTargetCoalescedCrit
NOTIFICATION-TYPE
SyncIQ errors are occurring for target
1.3.6.1.4.1.12124.250.14.21.3current
siqTargetCoalescedWarn
NOTIFICATION-TYPE
SyncIQ errors are occurring for target
1.3.6.1.4.1.12124.250.14.21.5current
jobEngineErrorEmerg
NOTIFICATION-TYPE
The cluster encountered one or more job failures.
1.3.6.1.4.1.12124.250.15.1.1current
jobEngineErrorCrit
NOTIFICATION-TYPE
The cluster encountered one or more job failures.
1.3.6.1.4.1.12124.250.15.1.3current
jobEngineErrorWarn
NOTIFICATION-TYPE
The cluster encountered one or more job failures.
1.3.6.1.4.1.12124.250.15.1.5current
jobEngineErrorInfo
NOTIFICATION-TYPE
The cluster encountered one or more job failures.
1.3.6.1.4.1.12124.250.15.1.7current
flexProtectRunningCrit
NOTIFICATION-TYPE
Cluster is in need of restripe but FlexProtect is not running
1.3.6.1.4.1.12124.250.15.2.3current
flexProtectRunningWarn
NOTIFICATION-TYPE
Cluster is in need of restripe but FlexProtect is not running
1.3.6.1.4.1.12124.250.15.2.5current
flexProtectRunningInfo
NOTIFICATION-TYPE
Cluster is in need of restripe but FlexProtect is not running
1.3.6.1.4.1.12124.250.15.2.7current
avscanInfectedFileCrit
NOTIFICATION-TYPE
AVScan found an infected file
1.3.6.1.4.1.12124.250.15.3.3current
avscanInfectedFileWarn
NOTIFICATION-TYPE
AVScan found an infected file
1.3.6.1.4.1.12124.250.15.3.5current
avscanInfectedFileInfo
NOTIFICATION-TYPE
AVScan found an infected file
1.3.6.1.4.1.12124.250.15.3.7current
mcpProcFailedWarn
NOTIFICATION-TYPE
MCP reports a process has failed on a node
1.3.6.1.4.1.12124.250.15.5.5current
mcpProcKilledWarn
NOTIFICATION-TYPE
MCP killed a process on a node
1.3.6.1.4.1.12124.250.15.6.5current
licenseExpirationWarn
NOTIFICATION-TYPE
One or more licenses has expired
1.3.6.1.4.1.12124.250.15.7.5current
licenseExpirationInfo
NOTIFICATION-TYPE
One or more licenses is about to expire
1.3.6.1.4.1.12124.250.15.7.7current
firmwareUpdateIncompleteWarn
NOTIFICATION-TYPE
A firmware update was not completely applied
1.3.6.1.4.1.12124.250.15.8.5current
testEventCrit
NOTIFICATION-TYPE
Test event
1.3.6.1.4.1.12124.250.15.9.3current
nodeCPUWarn
NOTIFICATION-TYPE
A node has exceeded the Warning-level CPU utilization.
1.3.6.1.4.1.12124.250.15.10.5current
nodeCPUInfo
NOTIFICATION-TYPE
A node has exceeded the Info-level CPU utilization.
1.3.6.1.4.1.12124.250.15.10.7current
mountdClientMountFailedInfo
NOTIFICATION-TYPE
Mountd denied client mount request
1.3.6.1.4.1.12124.250.15.11.7current
mountdHostLookupFailedInfo
NOTIFICATION-TYPE
Mountd host lookup failed
1.3.6.1.4.1.12124.250.15.12.7current
mixedSedNonSedClusterCrit
NOTIFICATION-TYPE
Cluster contains a mix of encrypting nodes and non-encrypting nodes
1.3.6.1.4.1.12124.250.15.13.3current
nfsCookieTranslationFailedInfo
NOTIFICATION-TYPE
64bit to 32bit cookie translation failed
1.3.6.1.4.1.12124.250.15.15.1current
avscanNoServersConfCrit
NOTIFICATION-TYPE
No ICAP servers configured for AVScan
1.3.6.1.4.1.12124.250.16.1.3current
avscanNoServersConfWarn
NOTIFICATION-TYPE
No ICAP servers configured for AVScan
1.3.6.1.4.1.12124.250.16.1.5current
avscanNoServersConfInfo
NOTIFICATION-TYPE
No ICAP servers configured for AVScan
1.3.6.1.4.1.12124.250.16.1.7current
avscanErrorCrit
NOTIFICATION-TYPE
AVscan has encountered an error
1.3.6.1.4.1.12124.250.16.2.3current
avscanErrorWarn
NOTIFICATION-TYPE
AVscan has encountered an error
1.3.6.1.4.1.12124.250.16.2.5current
avscanErrorInfo
NOTIFICATION-TYPE
AVscan has encountered an error
1.3.6.1.4.1.12124.250.16.2.7current
avscanCoalescedInfo
NOTIFICATION-TYPE
AVScan is detecting problems
1.3.6.1.4.1.12124.250.16.20.3current
avscanCoalescedWarn
NOTIFICATION-TYPE
AVScan is detecting problems
1.3.6.1.4.1.12124.250.16.20.5current
avscanCoalescedCrit
NOTIFICATION-TYPE
AVscan is detecting critical problems
1.3.6.1.4.1.12124.250.16.20.7current
clockSkewCrit
NOTIFICATION-TYPE
Windows ADS time skew outside limits.
1.3.6.1.4.1.12124.250.17.1.3current
sharePermsUpgradeFailCrit
NOTIFICATION-TYPE
Windows share permissions upgrade failed
1.3.6.1.4.1.12124.250.17.2.3current
winTimeConnectivityLostWarn
NOTIFICATION-TYPE
Connectivity to the Windows Time server was lost
1.3.6.1.4.1.12124.250.17.3.5current
winNetMapFullCrit
NOTIFICATION-TYPE
Windows ID map range is full. Authentication may fail.
1.3.6.1.4.1.12124.250.17.4.3current
winNetAuthCrit
NOTIFICATION-TYPE
Active Directory connectivity failure
1.3.6.1.4.1.12124.250.17.5.3current
winNetAuthWarn
NOTIFICATION-TYPE
Active Directory connectivity issue
1.3.6.1.4.1.12124.250.17.5.5current
lwioParamCrit
NOTIFICATION-TYPE
LWIO Parameter Invalid
1.3.6.1.4.1.12124.250.17.6.3current
winSmbUpgradeWarn
NOTIFICATION-TYPE
Windows networking
1.3.6.1.4.1.12124.250.17.7.2current
winSmbUpgradeCrit
NOTIFICATION-TYPE
Windows networking
1.3.6.1.4.1.12124.250.17.7.3current
winNetworkCoalesceCrit
NOTIFICATION-TYPE
There are problems with Windows networking components
1.3.6.1.4.1.12124.250.17.20.3current
winNetworkCoalesceWarn
NOTIFICATION-TYPE
There are problems with Windows networking components
1.3.6.1.4.1.12124.250.17.20.5current
winIDmapCoalesceCrit
NOTIFICATION-TYPE
There are problems with the Windows ID map
1.3.6.1.4.1.12124.250.17.21.3current
winIDmapCoalesceWarn
NOTIFICATION-TYPE
There are problems with the Windows ID map
1.3.6.1.4.1.12124.250.17.21.5current
winAuthCoalesceCrit
NOTIFICATION-TYPE
There are problems with Windows authentication components
1.3.6.1.4.1.12124.250.17.22.3current
winAuthCoalesceWarn
NOTIFICATION-TYPE
There are problems with Windows authentication components
1.3.6.1.4.1.12124.250.17.22.5current
winAuthUpgradeCrit
NOTIFICATION-TYPE
There are problems with upgrading authentication components
1.3.6.1.4.1.12124.250.17.23.3current
netStatusCrit
NOTIFICATION-TYPE
A network interface is down
1.3.6.1.4.1.12124.250.18.1.3current
netStatusWarn
NOTIFICATION-TYPE
A network interface is degraded or down
1.3.6.1.4.1.12124.250.18.1.5current
netStatusCoalescingCrit
NOTIFICATION-TYPE
Critical network problems are occurring
1.3.6.1.4.1.12124.250.18.20.3current
netStatusCoalescingWarn
NOTIFICATION-TYPE
Warning network problems are occurring
1.3.6.1.4.1.12124.250.18.20.5current
hardwareErrorMsgCrit
NOTIFICATION-TYPE
There is a message concerning a hardware faliure
1.3.6.1.4.1.12124.250.19.1.1.3current
hardwareErrorMsgWarn
NOTIFICATION-TYPE
There is a message concerning a potential hardware faliure
1.3.6.1.4.1.12124.250.19.1.1.5current
hardwareErrorCrit
NOTIFICATION-TYPE
A critical hardware error has occurred.
1.3.6.1.4.1.12124.250.19.1.3current
hardwareErrorWarn
NOTIFICATION-TYPE
A node has a hardware error
1.3.6.1.4.1.12124.250.19.1.5current
hardwareErrorInfo
NOTIFICATION-TYPE
A hardware problem is occurring.
1.3.6.1.4.1.12124.250.19.1.7current
hwErrorCrit
NOTIFICATION-TYPE
Power Supply AC Failiure.
1.3.6.1.4.1.12124.250.19.2.3current
diskNodeOfflineCrit
NOTIFICATION-TYPE
The expander is offline
1.3.6.1.4.1.12124.250.19.10.3current
hardwareCoalescedEmerg
NOTIFICATION-TYPE
There are hardware issues on a node
1.3.6.1.4.1.12124.250.19.20.1current
hardwareCoalescedCrit
NOTIFICATION-TYPE
There are hardware issues on a node
1.3.6.1.4.1.12124.250.19.20.3current
hardwareCoalescedWarn
NOTIFICATION-TYPE
There are hardware issues on a node
1.3.6.1.4.1.12124.250.19.20.5current
sensorCoalescedEmerg
NOTIFICATION-TYPE
There are sensor issues on a node
1.3.6.1.4.1.12124.250.19.50.1current
sensorCoalescedCrit
NOTIFICATION-TYPE
There are sensor issues on a node
1.3.6.1.4.1.12124.250.19.50.3current
sensorCoalescedWarn
NOTIFICATION-TYPE
There are sensor issues on a node
1.3.6.1.4.1.12124.250.19.50.5current
fanCoalescedEmerg
NOTIFICATION-TYPE
There are fan issues on a node
1.3.6.1.4.1.12124.250.19.51.1current
fanCoalescedCrit
NOTIFICATION-TYPE
There are fan issues on a node
1.3.6.1.4.1.12124.250.19.51.3current
fanCoalescedWarn
NOTIFICATION-TYPE
There are fan issues on a node
1.3.6.1.4.1.12124.250.19.51.5current
tempCoalescedEmerg
NOTIFICATION-TYPE
There are temp issues on a node
1.3.6.1.4.1.12124.250.19.52.1current
tempCoalescedCrit
NOTIFICATION-TYPE
There are temp issues on a node
1.3.6.1.4.1.12124.250.19.52.3current
tempCoalescedWarn
NOTIFICATION-TYPE
There are temp issues on a node
1.3.6.1.4.1.12124.250.19.52.5current
voltsCoalescedEmerg
NOTIFICATION-TYPE
There are voltage issues on a node
1.3.6.1.4.1.12124.250.19.53.1current
voltsCoalescedCrit
NOTIFICATION-TYPE
There are voltage issues on a node
1.3.6.1.4.1.12124.250.19.53.3current
voltsCoalescedWarn
NOTIFICATION-TYPE
There are voltage issues on a node
1.3.6.1.4.1.12124.250.19.53.5current
driveStatusInfo
NOTIFICATION-TYPE
A node has detected a problem with a drive
1.3.6.1.4.1.12124.250.20.1.1current
driveStatusCrit
NOTIFICATION-TYPE
A node has detected a problem with a drive
1.3.6.1.4.1.12124.250.20.1.3current
driveStatusWarn
NOTIFICATION-TYPE
A node has detected a problem with a drive
1.3.6.1.4.1.12124.250.20.1.5current
bootDiskFailCrit
NOTIFICATION-TYPE
Unhealthy boot disks, mirror is degraded.
1.3.6.1.4.1.12124.250.20.2.3current
bootDiskFailWarn
NOTIFICATION-TYPE
Unhealthy boot disks, mirror is degraded.
1.3.6.1.4.1.12124.250.20.2.5current
diskErrorWarn
NOTIFICATION-TYPE
A node's disks are having problems
1.3.6.1.4.1.12124.250.20.3.3current
bootdiskMirrorReqMissingCrit
NOTIFICATION-TYPE
Error creating mirror on bootdisks.
1.3.6.1.4.1.12124.250.20.4.3current
diskErrorCoalescedCrit
NOTIFICATION-TYPE
A node's disks are having critical problems
1.3.6.1.4.1.12124.250.20.20.3current
diskErrorCoalescedWarn
NOTIFICATION-TYPE
A node's disks are having warning level problems
1.3.6.1.4.1.12124.250.20.20.5current
hwPwrSupplyOverCrit
NOTIFICATION-TYPE
Power supply current over critical threshold
1.3.6.1.4.1.12124.250.21.1.1.3current
hwPwrSupplyOverWarn
NOTIFICATION-TYPE
Power supply current over warning threshold
1.3.6.1.4.1.12124.250.21.1.1.5current
hwPwrSupplyUnderCrit
NOTIFICATION-TYPE
Power supply current under critical threshold
1.3.6.1.4.1.12124.250.21.1.2.3current
hwPwrSupplyUnderWarn
NOTIFICATION-TYPE
Power supply current under warning threshold
1.3.6.1.4.1.12124.250.21.1.2.5current
hwFanOverCrit
NOTIFICATION-TYPE
A node's fan is over critical threshold
1.3.6.1.4.1.12124.250.21.2.1.3current
hwFanOverWarn
NOTIFICATION-TYPE
A node's fan is over warning threshold
1.3.6.1.4.1.12124.250.21.2.1.5current
hwFanOverInfo
NOTIFICATION-TYPE
A node's fan is over warning threshold
1.3.6.1.4.1.12124.250.21.2.1.7current
hwFanUnderCrit
NOTIFICATION-TYPE
A node's fan is under critical threshold
1.3.6.1.4.1.12124.250.21.2.2.3current
hwFanUnderWarn
NOTIFICATION-TYPE
A node's fan is under warning threshold
1.3.6.1.4.1.12124.250.21.2.2.5current
hwFanUnderInfo
NOTIFICATION-TYPE
A node's fan is under warning threshold
1.3.6.1.4.1.12124.250.21.2.2.7current
hwFanCrit
NOTIFICATION-TYPE
A node's fan failed
1.3.6.1.4.1.12124.250.21.2.3current
hwFanWarn
NOTIFICATION-TYPE
A node's fan monitor is about to fail
1.3.6.1.4.1.12124.250.21.2.5current
hwVoltageOverCrit
NOTIFICATION-TYPE
A node's voltage is over critical threshold
1.3.6.1.4.1.12124.250.21.10.1.3current
hwVoltageOverWarn
NOTIFICATION-TYPE
A node's voltage is over warning threshold
1.3.6.1.4.1.12124.250.21.10.1.5current
hwVoltageOverInfo
NOTIFICATION-TYPE
A node's voltage is over a threshold
1.3.6.1.4.1.12124.250.21.10.1.7current
hwVoltageUnderCrit
NOTIFICATION-TYPE
A node's voltage is under critical threshold
1.3.6.1.4.1.12124.250.21.10.2.3current
hwVoltageUnderWarn
NOTIFICATION-TYPE
A node's voltage is under warning threshold
1.3.6.1.4.1.12124.250.21.10.2.5current
hwVoltageUnderInfo
NOTIFICATION-TYPE
A node's voltage is under a threshold
1.3.6.1.4.1.12124.250.21.10.2.7current
hwTempOverEmerg
NOTIFICATION-TYPE
A node's temperature is over emergency threshold
1.3.6.1.4.1.12124.250.21.11.1.1current
hwTempOverCrit
NOTIFICATION-TYPE
A node's temperature is over critical threshold
1.3.6.1.4.1.12124.250.21.11.1.3current
hwTempOverWarn
NOTIFICATION-TYPE
A node's temperature is over warning threshold
1.3.6.1.4.1.12124.250.21.11.1.5current
hwTempOverInfo
NOTIFICATION-TYPE
A node's temperature is over a threshold
1.3.6.1.4.1.12124.250.21.11.1.7current
hwTempUnderEmerg
NOTIFICATION-TYPE
A node's temperature is under emergency threshold
1.3.6.1.4.1.12124.250.21.11.2.1current
hwTempUnderCrit
NOTIFICATION-TYPE
A node's temperature is under critical threshold
1.3.6.1.4.1.12124.250.21.11.2.3current
hwTempUnderWarn
NOTIFICATION-TYPE
A node's temperature is under warning threshold
1.3.6.1.4.1.12124.250.21.11.2.5current
hwTempUnderInfo
NOTIFICATION-TYPE
A node's temperature is under a threshold
1.3.6.1.4.1.12124.250.21.11.2.7current
hwPowerCrit
NOTIFICATION-TYPE
A node has a power supply problem
1.3.6.1.4.1.12124.250.21.12.3current
hwPowerWarn
NOTIFICATION-TYPE
A node has a power supply monitoring problem
1.3.6.1.4.1.12124.250.21.12.5current
hwMemCrit
NOTIFICATION-TYPE
A node is low on memory
1.3.6.1.4.1.12124.250.21.13.3current
hwCpuThrottleCrit
NOTIFICATION-TYPE
A node is at 100% CPU utilization
1.3.6.1.4.1.12124.250.21.14.3current
sensorMonitorCrit
NOTIFICATION-TYPE
A sensor failed
1.3.6.1.4.1.12124.250.21.15.1current
sensorMonitorWarn
NOTIFICATION-TYPE
A sensor is failing
1.3.6.1.4.1.12124.250.21.15.2current
hwCurrentOverEmerg
NOTIFICATION-TYPE
A node's current is over emergency threshold
1.3.6.1.4.1.12124.250.21.16.1.1current
hwCurrentOverCrit
NOTIFICATION-TYPE
A node's current is over critical threshold
1.3.6.1.4.1.12124.250.21.16.1.3current
hwCurrentOverWarn
NOTIFICATION-TYPE
A node's current is over warning threshold
1.3.6.1.4.1.12124.250.21.16.1.5current
hwCurrentOverInfo
NOTIFICATION-TYPE
A node's current is over a threshold
1.3.6.1.4.1.12124.250.21.16.1.7current
hwCurrentUnderEmerg
NOTIFICATION-TYPE
A node's current is under emergency threshold
1.3.6.1.4.1.12124.250.21.16.2.1current
hwCurrentUnderCrit
NOTIFICATION-TYPE
A node's current is under critical threshold
1.3.6.1.4.1.12124.250.21.16.2.3current
hwCurrentUnderWarn
NOTIFICATION-TYPE
A node's current is under warning threshold
1.3.6.1.4.1.12124.250.21.16.2.5current
hwCurrentUnderInfo
NOTIFICATION-TYPE
A node's current is under a threshold
1.3.6.1.4.1.12124.250.21.16.2.7current
sasPhyErrorExpanderWarn
NOTIFICATION-TYPE
A SAS PHY error was detected in the expander.
1.3.6.1.4.1.12124.250.22.1.5current
sasPhyErrorControllerWarn
NOTIFICATION-TYPE
A SAS PHY error was detected in the controller.
1.3.6.1.4.1.12124.250.22.1.7current
storageTransportCoalescedEmerg
NOTIFICATION-TYPE
There are storage transport issues on a node
1.3.6.1.4.1.12124.250.22.2.1current
storageCoalescedCrit
NOTIFICATION-TYPE
There are storage transport issues on a node
1.3.6.1.4.1.12124.250.22.2.3current
storageCoalescedWarn
NOTIFICATION-TYPE
There are storage transport issues on a node
1.3.6.1.4.1.12124.250.22.2.5current
cloudpoolNetworkErrorCrit
NOTIFICATION-TYPE
CloudPools network issues
1.3.6.1.4.1.12124.250.23.1.3current
cloudpoolAuthenticationErrorCrit
NOTIFICATION-TYPE
CloudPools authentication issues
1.3.6.1.4.1.12124.250.23.2.3current
cloudpoolAuthorizationErrorCrit
NOTIFICATION-TYPE
CloudPools authorization issues
1.3.6.1.4.1.12124.250.23.3.3current
cloudpoolBucketNotFoundErrorCrit
NOTIFICATION-TYPE
CloudPools bucket not found issues
1.3.6.1.4.1.12124.250.23.4.3current
cloudpoolObjectNotFoundErrorCrit
NOTIFICATION-TYPE
CloudPools Object not found issues
1.3.6.1.4.1.12124.250.23.5.3current
cloudpoolDataCorruptionIntegrityErrorEmerg
NOTIFICATION-TYPE
CloudPools data corruption integrity emergency issues
1.3.6.1.4.1.12124.250.23.6.1current
cloudpoolNoUsableAccountFoundErrorCrit
NOTIFICATION-TYPE
CloudPools no usable account found for the policy, cloudpool
1.3.6.1.4.1.12124.250.23.7.3current
cloudpoolCertificateErrorCrit
NOTIFICATION-TYPE
CloudPools Certificate issues
1.3.6.1.4.1.12124.250.23.8.3current
upgradeStartInfo
NOTIFICATION-TYPE
An upgrade or rollback has been started.
1.3.6.1.4.1.12124.250.24.1.7current
upgradeFinishInfo
NOTIFICATION-TYPE
An upgrade or rollback has finished.
1.3.6.1.4.1.12124.250.24.2.7current
upgradeClusterEventCrit
NOTIFICATION-TYPE
Upgrade cluster event.
1.3.6.1.4.1.12124.250.24.3.3current
upgradeClusterEventWarn
NOTIFICATION-TYPE
Upgrade cluster event.
1.3.6.1.4.1.12124.250.24.3.5current
upgradeClusterEventInfo
NOTIFICATION-TYPE
Upgrade cluster event.
1.3.6.1.4.1.12124.250.24.3.7current
upgradeNodeEventCrit
NOTIFICATION-TYPE
Upgrade node event.
1.3.6.1.4.1.12124.250.24.4.3current
upgradeNodeEventWarn
NOTIFICATION-TYPE
Upgrade node event.
1.3.6.1.4.1.12124.250.24.4.5current
upgradeNodeEventInfo
NOTIFICATION-TYPE
Upgrade node event.
1.3.6.1.4.1.12124.250.24.4.7current
upgradeRollbackStartInfo
NOTIFICATION-TYPE
Upgrade rollback start.
1.3.6.1.4.1.12124.250.24.5.7current

Conformance

NameOIDStatus
groupStateTrapsGroup
NOTIFICATION-GROUP
Collection of traps for group state.
1.3.6.1.4.1.12124.250.51.1current
filesystemTrapsGroup
NOTIFICATION-GROUP
Collection of filesystem traps.
1.3.6.1.4.1.12124.250.51.11current
smartQuotaTrapsGroup
NOTIFICATION-GROUP
Collection of smartQuota traps.
1.3.6.1.4.1.12124.250.51.12current
snapshotTrapsGroup
NOTIFICATION-GROUP
Collection of snapshot traps.
1.3.6.1.4.1.12124.250.51.13current
syncIQTrapsGroup
NOTIFICATION-GROUP
Collection of syncIQ traps.
1.3.6.1.4.1.12124.250.51.14current
softwareTrapsGroup
NOTIFICATION-GROUP
Collection of software traps.
1.3.6.1.4.1.12124.250.51.15current
avscanTrapsGroup
NOTIFICATION-GROUP
Collection of avscan traps.
1.3.6.1.4.1.12124.250.51.16current
netProtoTrapsGroup
NOTIFICATION-GROUP
Collection of net protocol traps.
1.3.6.1.4.1.12124.250.51.17current
networkingTrapsGroup
NOTIFICATION-GROUP
Collection of networking traps.
1.3.6.1.4.1.12124.250.51.18current
hardwareTrapsGroup
NOTIFICATION-GROUP
Collection of sensor traps.
1.3.6.1.4.1.12124.250.51.19current
systemDiskTrapsGroup
NOTIFICATION-GROUP
Collection of system disk traps.
1.3.6.1.4.1.12124.250.51.20current
sensorTrapsGroup
NOTIFICATION-GROUP
Collection of sensor traps.
1.3.6.1.4.1.12124.250.51.21current
storageTransportTrapsGroup
NOTIFICATION-GROUP
Collection of storage transport traps.
1.3.6.1.4.1.12124.250.51.22current
cloudPoolsTrapsGroup
NOTIFICATION-GROUP
Collection of cloud pools traps.
1.3.6.1.4.1.12124.250.51.23current
upgradeTrapsGroup
NOTIFICATION-GROUP
Collection of upgrade traps.
1.3.6.1.4.1.12124.250.51.24current
variablesGroup
OBJECT-GROUP
Collection of variable traps.
1.3.6.1.4.1.12124.250.51.50current
trapGroupCompliance
MODULE-COMPLIANCE
Compliance statement for the Isilon traps.
1.3.6.1.4.1.12124.250.52.1current