ISILON-TRAP-MIB
- Registered at
- 1.3.6.1.4.1.12124.250
- Last updated
- 2015-12-18 00:00
- Organization
- Isilon Systems LLC
- Revisions
- 2015-04-08 00:00, 2013-06-21 00:00, 2013-03-21 00:00, 2012-09-21 00:00, 2012-08-01 00:00, 2012-05-23 00:00, 2012-04-30 00:00, 2011-09-29 00:00, 2009-11-12 00:00, 2009-11-10 00:00
- Namespace
- emc
- Source file
ISILON-TRAP-MIB- Digest
sha256:8b5785fa4a5cf538ef31fb2867d7a21682f106cecbfeeebb43cd0a8ee583f7f9
Description
Traps for Isilon Systems OneFS operating system.
Contact
Isilon Systems LLC Support phone: 1-800.782.4362 Support website: http://support.emc.com
Imports
| From | Symbols |
|---|---|
| ISILON-MIB | isilon |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter64, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
HCNUM-TC ISILON-MIB ISILON-TRAP-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| groupStateTraps OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.10 | |||
| nodeStatus OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.10.1 | |||
| nodeExpStatus OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.10.2 | |||
| nodeShutdown OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.10.3 | |||
| nodeShutdownFail OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.10.4 | |||
| nodeRebootCoalesced OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.10.20 | |||
| nodeStatusCoalescing OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.10.21 | |||
| filesystemTraps OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.11 | |||
| partitionUsage OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.11.1 | |||
| clusterStorageUsage OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.11.2 | |||
| filesysError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.11.3 | |||
| diskPoolUsage OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.11.4 | |||
| diskPoolOldDbVersion OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.11.5 | |||
| ssdUsage OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.11.6 | |||
| filesysCoalesce OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.11.20 | |||
| smartQuotaTraps OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.12 | |||
| quotaThreshError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.12.1 | |||
| quotaNotifyError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.12.2 | |||
| quotaError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.12.3 | |||
| snapshotTraps OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.13 | |||
| snapshotError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.13.1 | |||
| snapshotReserve OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.13.2 | |||
| syncIQTraps OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.14 | |||
| siqEvent OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.14.1 | |||
| siqError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.14.2 | |||
| siqPolicyCoalesced OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.14.20 | |||
| siqTargetCoalesced OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.14.21 | |||
| softwareTraps OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.15 | |||
| jobEngineError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.15.1 | |||
| flexProtectRunning OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.15.2 | |||
| avscanInfectedFile OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.15.3 | |||
| mcpProcFailed OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.15.5 | |||
| mcpProcKilled OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.15.6 | |||
| licenseExpiration OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.15.7 | |||
| firmwareUpdateIncomplete OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.15.8 | |||
| testEvent OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.15.9 | |||
| nodeCPU OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.15.10 | |||
| mountdClientMountFailed OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.15.11 | |||
| mountdHostLookupFailed OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.15.12 | |||
| mixedSedNonSedCluster OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.15.13 | |||
| nfsCookieTranslationFailed OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.15.15 | |||
| avscanTraps OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.16 | |||
| avscanNoServersConf OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.16.1 | |||
| avscanError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.16.2 | |||
| avscanCoalesced OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.16.20 | |||
| netProtoTraps OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.17 | |||
| clockSkew OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.17.1 | |||
| sharePermsUpgradeFail OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.17.2 | |||
| winTimeConnectivityLost OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.17.3 | |||
| winNetMapFull OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.17.4 | |||
| winNetAuth OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.17.5 | |||
| lwioParam OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.17.6 | |||
| winSmbUpgrade OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.17.7 | |||
| winNetworkCoalesce OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.17.20 | |||
| winIDmapCoalesce OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.17.21 | |||
| winAuthCoalesce OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.17.22 | |||
| winAuthUpgrade OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.17.23 | |||
| networkingTraps OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.18 | |||
| netStatus OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.18.1 | |||
| netStatusCoalescing OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.18.20 | |||
| hardwareTraps OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.19 | |||
| hardwareError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.19.1 | |||
| hardwareErrorMsg OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.19.1.1 | |||
| hwError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.19.2 | |||
| diskNodeOffline OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.19.10 | |||
| hardwareCoalesced OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.19.20 | |||
| sensorCoalesced OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.19.50 | |||
| fanCoalesced OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.19.51 | |||
| tempCoalesced OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.19.52 | |||
| voltsCoalesced OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.19.53 | |||
| systemDiskTraps OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.20 | |||
| driveStatus OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.20.1 | |||
| bootDiskFail OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.20.2 | |||
| diskError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.20.3 | |||
| bootDiskMirrorReqMissing OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.20.4 | |||
| diskErrorCoalesced OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.20.20 | |||
| sensorTraps OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21 | |||
| hwPwrSupply OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.1 | |||
| hwPwrSupplyOver OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.1.1 | |||
| hwPwrSupplyUnder OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.1.2 | |||
| hwFan OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.2 | |||
| hwFanOver OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.2.1 | |||
| hwFanUnder OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.2.2 | |||
| hwVoltage OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.10 | |||
| hwVoltageOver OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.10.1 | |||
| hwVoltageUnder OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.10.2 | |||
| hwTemp OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.11 | |||
| hwTempOver OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.11.1 | |||
| hwTempUnder OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.11.2 | |||
| hwPower OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.12 | |||
| hwMem OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.13 | |||
| hwCpuThrottle OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.14 | |||
| sensorMonitor OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.15 | |||
| hwCurrent OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.16 | |||
| hwCurrentOver OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.16.1 | |||
| hwCurrentUnder OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.21.16.2 | |||
| storageTransportTraps OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.22 | |||
| sasPhyError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.22.1 | |||
| storageTransportCoalesced OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.22.2 | |||
| cloudPoolsTraps OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.23 | |||
| cloudpoolNetworkError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.23.1 | |||
| cloudpoolAuthenticationError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.23.2 | |||
| cloudpoolAuthorizationError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.23.3 | |||
| cloudpoolBucketNotFoundError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.23.4 | |||
| cloudpoolObjectNotFoundError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.23.5 | |||
| cloudpoolDataCorruptionIntegrityError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.23.6 | |||
| cloudpoolNoUsableAccountFoundError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.23.7 | |||
| cloudpoolCertificateError OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.23.8 | |||
| upgradeTraps OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.24 | |||
| upgradeStart OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.24.1 | |||
| upgradeFinish OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.24.2 | |||
| upgradeClusterEvent OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.24.3 | |||
| upgradeNodeEvent OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.24.4 | |||
| upgradeRollbackStart OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.24.5 | |||
| variables OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.50 | |||
| nodeIdentifier OBJECT-TYPE The Logical Node Number of the node referenced in the notification. | 1.3.6.1.4.1.12124.250.50.1 | Integer32 | accessible-for-notify | current |
| measuredValue OBJECT-TYPE The measured value that triggered the event | 1.3.6.1.4.1.12124.250.50.2 | Integer32 | accessible-for-notify | current |
| units OBJECT-TYPE The units of the measurement | 1.3.6.1.4.1.12124.250.50.3 | OCTET STRING | accessible-for-notify | current |
| oid OBJECT-TYPE The OID of the sensor reporting a problem | 1.3.6.1.4.1.12124.250.50.4 | OBJECT IDENTIFIER | accessible-for-notify | current |
| bay OBJECT-TYPE Drive bay number | 1.3.6.1.4.1.12124.250.50.5 | Integer32 | accessible-for-notify | current |
| ifName OBJECT-TYPE Interface name | 1.3.6.1.4.1.12124.250.50.6 | OCTET STRING | accessible-for-notify | current |
| phy OBJECT-TYPE PHY connection | 1.3.6.1.4.1.12124.250.50.7 | Integer32 | accessible-for-notify | current |
| errorMessage OBJECT-TYPE Error message | 1.3.6.1.4.1.12124.250.50.8 | OCTET STRING | accessible-for-notify | current |
| errno OBJECT-TYPE Error number | 1.3.6.1.4.1.12124.250.50.9 | Integer32 | accessible-for-notify | current |
| stringArg OBJECT-TYPE A trap-related string argument. | 1.3.6.1.4.1.12124.250.50.10 | OCTET STRING | accessible-for-notify | current |
| message OBJECT-TYPE A trap-related message string. | 1.3.6.1.4.1.12124.250.50.11 | OCTET STRING | accessible-for-notify | current |
| i64Arg OBJECT-TYPE Error number | 1.3.6.1.4.1.12124.250.50.12 | Counter64 | accessible-for-notify | current |
| i32Arg OBJECT-TYPE Integer argument | 1.3.6.1.4.1.12124.250.50.13 | Integer32 | accessible-for-notify | current |
| measuredValueStr OBJECT-TYPE The measured value that triggered the event represented as string | 1.3.6.1.4.1.12124.250.50.14 | OCTET STRING | accessible-for-notify | current |
| instanceIdentifier OBJECT-TYPE Instance ID of event generating the trap | 1.3.6.1.4.1.12124.250.50.15 | OCTET STRING | accessible-for-notify | current |
| deviceIdentifier OBJECT-TYPE The Device Node Number of the node referenced in the notification. | 1.3.6.1.4.1.12124.250.50.16 | Integer32 | accessible-for-notify | current |
| trapConformance OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.51 | |||
| trapCompliance OBJECT-IDENTITY | 1.3.6.1.4.1.12124.250.52 |
Notifications
| Name | OID | Status |
|---|---|---|
| nodeStatusCrit NOTIFICATION-TYPE A critical node status event has occurred. | 1.3.6.1.4.1.12124.250.10.1.3 | current |
| nodeStatusInfo NOTIFICATION-TYPE A node status event has occurred. | 1.3.6.1.4.1.12124.250.10.1.7 | current |
| nodeExpStatusCrit NOTIFICATION-TYPE A disk-only node has gone offline and cannot be contacted by the cluster. | 1.3.6.1.4.1.12124.250.10.2.3 | current |
| nodeShutdownInfo NOTIFICATION-TYPE A node is being shut down or rebooted. | 1.3.6.1.4.1.12124.250.10.3.7 | current |
| nodeShutdownFailCrit NOTIFICATION-TYPE Shut down or reboot failed for a node. | 1.3.6.1.4.1.12124.250.10.4.3 | current |
| nodeRebootCoalescedInfo NOTIFICATION-TYPE A node is being rebooted. | 1.3.6.1.4.1.12124.250.10.20.7 | current |
| nodeStatusCoalescingCrit NOTIFICATION-TYPE Critical node status events are occurring | 1.3.6.1.4.1.12124.250.10.21.3 | current |
| nodeStatusCoalescingWarn NOTIFICATION-TYPE Warning node status events are occurring | 1.3.6.1.4.1.12124.250.10.21.5 | current |
| partitionUsageCrit NOTIFICATION-TYPE A partition is over the critical threshold percentage. | 1.3.6.1.4.1.12124.250.11.1.3 | current |
| partitionUsageWarn NOTIFICATION-TYPE A partition is over the warning threshold percentage. | 1.3.6.1.4.1.12124.250.11.1.5 | current |
| partitionUsageInfo NOTIFICATION-TYPE A partition is over the info threshold percentage. | 1.3.6.1.4.1.12124.250.11.1.7 | current |
| clusterStorageUsageCrit NOTIFICATION-TYPE The /ifs partition is near capacity. | 1.3.6.1.4.1.12124.250.11.2.3 | current |
| clusterStorageUsageWarn NOTIFICATION-TYPE The /ifs partition is near capacity. | 1.3.6.1.4.1.12124.250.11.2.5 | current |
| filesysErrorCrit NOTIFICATION-TYPE A critical /ifs filesystem error has occurred | 1.3.6.1.4.1.12124.250.11.3.3 | current |
| filesysErrorWarn NOTIFICATION-TYPE A warning-level /ifs filesystem error has occurred | 1.3.6.1.4.1.12124.250.11.3.5 | current |
| filesysErrorInfo NOTIFICATION-TYPE An /ifs filesystem error has occurred. | 1.3.6.1.4.1.12124.250.11.3.7 | current |
| diskPoolUsageCrit NOTIFICATION-TYPE A disk pool is near capacity. | 1.3.6.1.4.1.12124.250.11.4.3 | current |
| diskPoolUsageWarn NOTIFICATION-TYPE A disk pool is near capacity. | 1.3.6.1.4.1.12124.250.11.4.5 | current |
| diskPoolOldDbVersionWarn NOTIFICATION-TYPE The SmartPools upgrade has not completed. | 1.3.6.1.4.1.12124.250.11.5.5 | current |
| ssdUsageCrit NOTIFICATION-TYPE The SSD drives are at capacity. | 1.3.6.1.4.1.12124.250.11.6.1 | current |
| ssdUsageWarn NOTIFICATION-TYPE The SSD drives are near capacity. | 1.3.6.1.4.1.12124.250.11.6.2 | current |
| ssdUsageInfo NOTIFICATION-TYPE The SSD drives are near capacity. | 1.3.6.1.4.1.12124.250.11.6.3 | current |
| filesysCoalesceCrit NOTIFICATION-TYPE Filesystem issues are occurring at a critical level | 1.3.6.1.4.1.12124.250.11.20.3 | current |
| filesysCoalesceWarn NOTIFICATION-TYPE Filesystem issues are occurring at a warning level | 1.3.6.1.4.1.12124.250.11.20.5 | current |
| quotaThreshErrorInfo NOTIFICATION-TYPE SmartQuotas threshold violation | 1.3.6.1.4.1.12124.250.12.1.7 | current |
| quotaNotifyErrorWarn NOTIFICATION-TYPE SmartQuotas threshold notification failed | 1.3.6.1.4.1.12124.250.12.2.5 | current |
| quotaErrorWarn NOTIFICATION-TYPE SmartQuotas error | 1.3.6.1.4.1.12124.250.12.3.5 | current |
| snapshotErrorWarn NOTIFICATION-TYPE Snapshot error | 1.3.6.1.4.1.12124.250.13.1.5 | current |
| snapshotReserveCrit NOTIFICATION-TYPE Snapshot reserve space is over its critical limit | 1.3.6.1.4.1.12124.250.13.2.3 | current |
| snapshotReserveWarn NOTIFICATION-TYPE Snapshot reserve space is over its warning limit | 1.3.6.1.4.1.12124.250.13.2.5 | current |
| siqEventCrit NOTIFICATION-TYPE SyncIQ event | 1.3.6.1.4.1.12124.250.14.1.3 | current |
| siqEventWarn NOTIFICATION-TYPE SyncIQ event | 1.3.6.1.4.1.12124.250.14.1.5 | current |
| siqErrorWarn NOTIFICATION-TYPE SyncIQ error | 1.3.6.1.4.1.12124.250.14.2.5 | current |
| siqPolicyCoalescedCrit NOTIFICATION-TYPE SyncIQ policy errors are occurring | 1.3.6.1.4.1.12124.250.14.20.3 | current |
| siqPolicyCoalescedWarn NOTIFICATION-TYPE SyncIQ policy errors are occurring | 1.3.6.1.4.1.12124.250.14.20.5 | current |
| siqTargetCoalescedCrit NOTIFICATION-TYPE SyncIQ errors are occurring for target | 1.3.6.1.4.1.12124.250.14.21.3 | current |
| siqTargetCoalescedWarn NOTIFICATION-TYPE SyncIQ errors are occurring for target | 1.3.6.1.4.1.12124.250.14.21.5 | current |
| jobEngineErrorEmerg NOTIFICATION-TYPE The cluster encountered one or more job failures. | 1.3.6.1.4.1.12124.250.15.1.1 | current |
| jobEngineErrorCrit NOTIFICATION-TYPE The cluster encountered one or more job failures. | 1.3.6.1.4.1.12124.250.15.1.3 | current |
| jobEngineErrorWarn NOTIFICATION-TYPE The cluster encountered one or more job failures. | 1.3.6.1.4.1.12124.250.15.1.5 | current |
| jobEngineErrorInfo NOTIFICATION-TYPE The cluster encountered one or more job failures. | 1.3.6.1.4.1.12124.250.15.1.7 | current |
| flexProtectRunningCrit NOTIFICATION-TYPE Cluster is in need of restripe but FlexProtect is not running | 1.3.6.1.4.1.12124.250.15.2.3 | current |
| flexProtectRunningWarn NOTIFICATION-TYPE Cluster is in need of restripe but FlexProtect is not running | 1.3.6.1.4.1.12124.250.15.2.5 | current |
| flexProtectRunningInfo NOTIFICATION-TYPE Cluster is in need of restripe but FlexProtect is not running | 1.3.6.1.4.1.12124.250.15.2.7 | current |
| avscanInfectedFileCrit NOTIFICATION-TYPE AVScan found an infected file | 1.3.6.1.4.1.12124.250.15.3.3 | current |
| avscanInfectedFileWarn NOTIFICATION-TYPE AVScan found an infected file | 1.3.6.1.4.1.12124.250.15.3.5 | current |
| avscanInfectedFileInfo NOTIFICATION-TYPE AVScan found an infected file | 1.3.6.1.4.1.12124.250.15.3.7 | current |
| mcpProcFailedWarn NOTIFICATION-TYPE MCP reports a process has failed on a node | 1.3.6.1.4.1.12124.250.15.5.5 | current |
| mcpProcKilledWarn NOTIFICATION-TYPE MCP killed a process on a node | 1.3.6.1.4.1.12124.250.15.6.5 | current |
| licenseExpirationWarn NOTIFICATION-TYPE One or more licenses has expired | 1.3.6.1.4.1.12124.250.15.7.5 | current |
| licenseExpirationInfo NOTIFICATION-TYPE One or more licenses is about to expire | 1.3.6.1.4.1.12124.250.15.7.7 | current |
| firmwareUpdateIncompleteWarn NOTIFICATION-TYPE A firmware update was not completely applied | 1.3.6.1.4.1.12124.250.15.8.5 | current |
| testEventCrit NOTIFICATION-TYPE Test event | 1.3.6.1.4.1.12124.250.15.9.3 | current |
| nodeCPUWarn NOTIFICATION-TYPE A node has exceeded the Warning-level CPU utilization. | 1.3.6.1.4.1.12124.250.15.10.5 | current |
| nodeCPUInfo NOTIFICATION-TYPE A node has exceeded the Info-level CPU utilization. | 1.3.6.1.4.1.12124.250.15.10.7 | current |
| mountdClientMountFailedInfo NOTIFICATION-TYPE Mountd denied client mount request | 1.3.6.1.4.1.12124.250.15.11.7 | current |
| mountdHostLookupFailedInfo NOTIFICATION-TYPE Mountd host lookup failed | 1.3.6.1.4.1.12124.250.15.12.7 | current |
| mixedSedNonSedClusterCrit NOTIFICATION-TYPE Cluster contains a mix of encrypting nodes and non-encrypting nodes | 1.3.6.1.4.1.12124.250.15.13.3 | current |
| nfsCookieTranslationFailedInfo NOTIFICATION-TYPE 64bit to 32bit cookie translation failed | 1.3.6.1.4.1.12124.250.15.15.1 | current |
| avscanNoServersConfCrit NOTIFICATION-TYPE No ICAP servers configured for AVScan | 1.3.6.1.4.1.12124.250.16.1.3 | current |
| avscanNoServersConfWarn NOTIFICATION-TYPE No ICAP servers configured for AVScan | 1.3.6.1.4.1.12124.250.16.1.5 | current |
| avscanNoServersConfInfo NOTIFICATION-TYPE No ICAP servers configured for AVScan | 1.3.6.1.4.1.12124.250.16.1.7 | current |
| avscanErrorCrit NOTIFICATION-TYPE AVscan has encountered an error | 1.3.6.1.4.1.12124.250.16.2.3 | current |
| avscanErrorWarn NOTIFICATION-TYPE AVscan has encountered an error | 1.3.6.1.4.1.12124.250.16.2.5 | current |
| avscanErrorInfo NOTIFICATION-TYPE AVscan has encountered an error | 1.3.6.1.4.1.12124.250.16.2.7 | current |
| avscanCoalescedInfo NOTIFICATION-TYPE AVScan is detecting problems | 1.3.6.1.4.1.12124.250.16.20.3 | current |
| avscanCoalescedWarn NOTIFICATION-TYPE AVScan is detecting problems | 1.3.6.1.4.1.12124.250.16.20.5 | current |
| avscanCoalescedCrit NOTIFICATION-TYPE AVscan is detecting critical problems | 1.3.6.1.4.1.12124.250.16.20.7 | current |
| clockSkewCrit NOTIFICATION-TYPE Windows ADS time skew outside limits. | 1.3.6.1.4.1.12124.250.17.1.3 | current |
| sharePermsUpgradeFailCrit NOTIFICATION-TYPE Windows share permissions upgrade failed | 1.3.6.1.4.1.12124.250.17.2.3 | current |
| winTimeConnectivityLostWarn NOTIFICATION-TYPE Connectivity to the Windows Time server was lost | 1.3.6.1.4.1.12124.250.17.3.5 | current |
| winNetMapFullCrit NOTIFICATION-TYPE Windows ID map range is full. Authentication may fail. | 1.3.6.1.4.1.12124.250.17.4.3 | current |
| winNetAuthCrit NOTIFICATION-TYPE Active Directory connectivity failure | 1.3.6.1.4.1.12124.250.17.5.3 | current |
| winNetAuthWarn NOTIFICATION-TYPE Active Directory connectivity issue | 1.3.6.1.4.1.12124.250.17.5.5 | current |
| lwioParamCrit NOTIFICATION-TYPE LWIO Parameter Invalid | 1.3.6.1.4.1.12124.250.17.6.3 | current |
| winSmbUpgradeWarn NOTIFICATION-TYPE Windows networking | 1.3.6.1.4.1.12124.250.17.7.2 | current |
| winSmbUpgradeCrit NOTIFICATION-TYPE Windows networking | 1.3.6.1.4.1.12124.250.17.7.3 | current |
| winNetworkCoalesceCrit NOTIFICATION-TYPE There are problems with Windows networking components | 1.3.6.1.4.1.12124.250.17.20.3 | current |
| winNetworkCoalesceWarn NOTIFICATION-TYPE There are problems with Windows networking components | 1.3.6.1.4.1.12124.250.17.20.5 | current |
| winIDmapCoalesceCrit NOTIFICATION-TYPE There are problems with the Windows ID map | 1.3.6.1.4.1.12124.250.17.21.3 | current |
| winIDmapCoalesceWarn NOTIFICATION-TYPE There are problems with the Windows ID map | 1.3.6.1.4.1.12124.250.17.21.5 | current |
| winAuthCoalesceCrit NOTIFICATION-TYPE There are problems with Windows authentication components | 1.3.6.1.4.1.12124.250.17.22.3 | current |
| winAuthCoalesceWarn NOTIFICATION-TYPE There are problems with Windows authentication components | 1.3.6.1.4.1.12124.250.17.22.5 | current |
| winAuthUpgradeCrit NOTIFICATION-TYPE There are problems with upgrading authentication components | 1.3.6.1.4.1.12124.250.17.23.3 | current |
| netStatusCrit NOTIFICATION-TYPE A network interface is down | 1.3.6.1.4.1.12124.250.18.1.3 | current |
| netStatusWarn NOTIFICATION-TYPE A network interface is degraded or down | 1.3.6.1.4.1.12124.250.18.1.5 | current |
| netStatusCoalescingCrit NOTIFICATION-TYPE Critical network problems are occurring | 1.3.6.1.4.1.12124.250.18.20.3 | current |
| netStatusCoalescingWarn NOTIFICATION-TYPE Warning network problems are occurring | 1.3.6.1.4.1.12124.250.18.20.5 | current |
| hardwareErrorMsgCrit NOTIFICATION-TYPE There is a message concerning a hardware faliure | 1.3.6.1.4.1.12124.250.19.1.1.3 | current |
| hardwareErrorMsgWarn NOTIFICATION-TYPE There is a message concerning a potential hardware faliure | 1.3.6.1.4.1.12124.250.19.1.1.5 | current |
| hardwareErrorCrit NOTIFICATION-TYPE A critical hardware error has occurred. | 1.3.6.1.4.1.12124.250.19.1.3 | current |
| hardwareErrorWarn NOTIFICATION-TYPE A node has a hardware error | 1.3.6.1.4.1.12124.250.19.1.5 | current |
| hardwareErrorInfo NOTIFICATION-TYPE A hardware problem is occurring. | 1.3.6.1.4.1.12124.250.19.1.7 | current |
| hwErrorCrit NOTIFICATION-TYPE Power Supply AC Failiure. | 1.3.6.1.4.1.12124.250.19.2.3 | current |
| diskNodeOfflineCrit NOTIFICATION-TYPE The expander is offline | 1.3.6.1.4.1.12124.250.19.10.3 | current |
| hardwareCoalescedEmerg NOTIFICATION-TYPE There are hardware issues on a node | 1.3.6.1.4.1.12124.250.19.20.1 | current |
| hardwareCoalescedCrit NOTIFICATION-TYPE There are hardware issues on a node | 1.3.6.1.4.1.12124.250.19.20.3 | current |
| hardwareCoalescedWarn NOTIFICATION-TYPE There are hardware issues on a node | 1.3.6.1.4.1.12124.250.19.20.5 | current |
| sensorCoalescedEmerg NOTIFICATION-TYPE There are sensor issues on a node | 1.3.6.1.4.1.12124.250.19.50.1 | current |
| sensorCoalescedCrit NOTIFICATION-TYPE There are sensor issues on a node | 1.3.6.1.4.1.12124.250.19.50.3 | current |
| sensorCoalescedWarn NOTIFICATION-TYPE There are sensor issues on a node | 1.3.6.1.4.1.12124.250.19.50.5 | current |
| fanCoalescedEmerg NOTIFICATION-TYPE There are fan issues on a node | 1.3.6.1.4.1.12124.250.19.51.1 | current |
| fanCoalescedCrit NOTIFICATION-TYPE There are fan issues on a node | 1.3.6.1.4.1.12124.250.19.51.3 | current |
| fanCoalescedWarn NOTIFICATION-TYPE There are fan issues on a node | 1.3.6.1.4.1.12124.250.19.51.5 | current |
| tempCoalescedEmerg NOTIFICATION-TYPE There are temp issues on a node | 1.3.6.1.4.1.12124.250.19.52.1 | current |
| tempCoalescedCrit NOTIFICATION-TYPE There are temp issues on a node | 1.3.6.1.4.1.12124.250.19.52.3 | current |
| tempCoalescedWarn NOTIFICATION-TYPE There are temp issues on a node | 1.3.6.1.4.1.12124.250.19.52.5 | current |
| voltsCoalescedEmerg NOTIFICATION-TYPE There are voltage issues on a node | 1.3.6.1.4.1.12124.250.19.53.1 | current |
| voltsCoalescedCrit NOTIFICATION-TYPE There are voltage issues on a node | 1.3.6.1.4.1.12124.250.19.53.3 | current |
| voltsCoalescedWarn NOTIFICATION-TYPE There are voltage issues on a node | 1.3.6.1.4.1.12124.250.19.53.5 | current |
| driveStatusInfo NOTIFICATION-TYPE A node has detected a problem with a drive | 1.3.6.1.4.1.12124.250.20.1.1 | current |
| driveStatusCrit NOTIFICATION-TYPE A node has detected a problem with a drive | 1.3.6.1.4.1.12124.250.20.1.3 | current |
| driveStatusWarn NOTIFICATION-TYPE A node has detected a problem with a drive | 1.3.6.1.4.1.12124.250.20.1.5 | current |
| bootDiskFailCrit NOTIFICATION-TYPE Unhealthy boot disks, mirror is degraded. | 1.3.6.1.4.1.12124.250.20.2.3 | current |
| bootDiskFailWarn NOTIFICATION-TYPE Unhealthy boot disks, mirror is degraded. | 1.3.6.1.4.1.12124.250.20.2.5 | current |
| diskErrorWarn NOTIFICATION-TYPE A node's disks are having problems | 1.3.6.1.4.1.12124.250.20.3.3 | current |
| bootdiskMirrorReqMissingCrit NOTIFICATION-TYPE Error creating mirror on bootdisks. | 1.3.6.1.4.1.12124.250.20.4.3 | current |
| diskErrorCoalescedCrit NOTIFICATION-TYPE A node's disks are having critical problems | 1.3.6.1.4.1.12124.250.20.20.3 | current |
| diskErrorCoalescedWarn NOTIFICATION-TYPE A node's disks are having warning level problems | 1.3.6.1.4.1.12124.250.20.20.5 | current |
| hwPwrSupplyOverCrit NOTIFICATION-TYPE Power supply current over critical threshold | 1.3.6.1.4.1.12124.250.21.1.1.3 | current |
| hwPwrSupplyOverWarn NOTIFICATION-TYPE Power supply current over warning threshold | 1.3.6.1.4.1.12124.250.21.1.1.5 | current |
| hwPwrSupplyUnderCrit NOTIFICATION-TYPE Power supply current under critical threshold | 1.3.6.1.4.1.12124.250.21.1.2.3 | current |
| hwPwrSupplyUnderWarn NOTIFICATION-TYPE Power supply current under warning threshold | 1.3.6.1.4.1.12124.250.21.1.2.5 | current |
| hwFanOverCrit NOTIFICATION-TYPE A node's fan is over critical threshold | 1.3.6.1.4.1.12124.250.21.2.1.3 | current |
| hwFanOverWarn NOTIFICATION-TYPE A node's fan is over warning threshold | 1.3.6.1.4.1.12124.250.21.2.1.5 | current |
| hwFanOverInfo NOTIFICATION-TYPE A node's fan is over warning threshold | 1.3.6.1.4.1.12124.250.21.2.1.7 | current |
| hwFanUnderCrit NOTIFICATION-TYPE A node's fan is under critical threshold | 1.3.6.1.4.1.12124.250.21.2.2.3 | current |
| hwFanUnderWarn NOTIFICATION-TYPE A node's fan is under warning threshold | 1.3.6.1.4.1.12124.250.21.2.2.5 | current |
| hwFanUnderInfo NOTIFICATION-TYPE A node's fan is under warning threshold | 1.3.6.1.4.1.12124.250.21.2.2.7 | current |
| hwFanCrit NOTIFICATION-TYPE A node's fan failed | 1.3.6.1.4.1.12124.250.21.2.3 | current |
| hwFanWarn NOTIFICATION-TYPE A node's fan monitor is about to fail | 1.3.6.1.4.1.12124.250.21.2.5 | current |
| hwVoltageOverCrit NOTIFICATION-TYPE A node's voltage is over critical threshold | 1.3.6.1.4.1.12124.250.21.10.1.3 | current |
| hwVoltageOverWarn NOTIFICATION-TYPE A node's voltage is over warning threshold | 1.3.6.1.4.1.12124.250.21.10.1.5 | current |
| hwVoltageOverInfo NOTIFICATION-TYPE A node's voltage is over a threshold | 1.3.6.1.4.1.12124.250.21.10.1.7 | current |
| hwVoltageUnderCrit NOTIFICATION-TYPE A node's voltage is under critical threshold | 1.3.6.1.4.1.12124.250.21.10.2.3 | current |
| hwVoltageUnderWarn NOTIFICATION-TYPE A node's voltage is under warning threshold | 1.3.6.1.4.1.12124.250.21.10.2.5 | current |
| hwVoltageUnderInfo NOTIFICATION-TYPE A node's voltage is under a threshold | 1.3.6.1.4.1.12124.250.21.10.2.7 | current |
| hwTempOverEmerg NOTIFICATION-TYPE A node's temperature is over emergency threshold | 1.3.6.1.4.1.12124.250.21.11.1.1 | current |
| hwTempOverCrit NOTIFICATION-TYPE A node's temperature is over critical threshold | 1.3.6.1.4.1.12124.250.21.11.1.3 | current |
| hwTempOverWarn NOTIFICATION-TYPE A node's temperature is over warning threshold | 1.3.6.1.4.1.12124.250.21.11.1.5 | current |
| hwTempOverInfo NOTIFICATION-TYPE A node's temperature is over a threshold | 1.3.6.1.4.1.12124.250.21.11.1.7 | current |
| hwTempUnderEmerg NOTIFICATION-TYPE A node's temperature is under emergency threshold | 1.3.6.1.4.1.12124.250.21.11.2.1 | current |
| hwTempUnderCrit NOTIFICATION-TYPE A node's temperature is under critical threshold | 1.3.6.1.4.1.12124.250.21.11.2.3 | current |
| hwTempUnderWarn NOTIFICATION-TYPE A node's temperature is under warning threshold | 1.3.6.1.4.1.12124.250.21.11.2.5 | current |
| hwTempUnderInfo NOTIFICATION-TYPE A node's temperature is under a threshold | 1.3.6.1.4.1.12124.250.21.11.2.7 | current |
| hwPowerCrit NOTIFICATION-TYPE A node has a power supply problem | 1.3.6.1.4.1.12124.250.21.12.3 | current |
| hwPowerWarn NOTIFICATION-TYPE A node has a power supply monitoring problem | 1.3.6.1.4.1.12124.250.21.12.5 | current |
| hwMemCrit NOTIFICATION-TYPE A node is low on memory | 1.3.6.1.4.1.12124.250.21.13.3 | current |
| hwCpuThrottleCrit NOTIFICATION-TYPE A node is at 100% CPU utilization | 1.3.6.1.4.1.12124.250.21.14.3 | current |
| sensorMonitorCrit NOTIFICATION-TYPE A sensor failed | 1.3.6.1.4.1.12124.250.21.15.1 | current |
| sensorMonitorWarn NOTIFICATION-TYPE A sensor is failing | 1.3.6.1.4.1.12124.250.21.15.2 | current |
| hwCurrentOverEmerg NOTIFICATION-TYPE A node's current is over emergency threshold | 1.3.6.1.4.1.12124.250.21.16.1.1 | current |
| hwCurrentOverCrit NOTIFICATION-TYPE A node's current is over critical threshold | 1.3.6.1.4.1.12124.250.21.16.1.3 | current |
| hwCurrentOverWarn NOTIFICATION-TYPE A node's current is over warning threshold | 1.3.6.1.4.1.12124.250.21.16.1.5 | current |
| hwCurrentOverInfo NOTIFICATION-TYPE A node's current is over a threshold | 1.3.6.1.4.1.12124.250.21.16.1.7 | current |
| hwCurrentUnderEmerg NOTIFICATION-TYPE A node's current is under emergency threshold | 1.3.6.1.4.1.12124.250.21.16.2.1 | current |
| hwCurrentUnderCrit NOTIFICATION-TYPE A node's current is under critical threshold | 1.3.6.1.4.1.12124.250.21.16.2.3 | current |
| hwCurrentUnderWarn NOTIFICATION-TYPE A node's current is under warning threshold | 1.3.6.1.4.1.12124.250.21.16.2.5 | current |
| hwCurrentUnderInfo NOTIFICATION-TYPE A node's current is under a threshold | 1.3.6.1.4.1.12124.250.21.16.2.7 | current |
| sasPhyErrorExpanderWarn NOTIFICATION-TYPE A SAS PHY error was detected in the expander. | 1.3.6.1.4.1.12124.250.22.1.5 | current |
| sasPhyErrorControllerWarn NOTIFICATION-TYPE A SAS PHY error was detected in the controller. | 1.3.6.1.4.1.12124.250.22.1.7 | current |
| storageTransportCoalescedEmerg NOTIFICATION-TYPE There are storage transport issues on a node | 1.3.6.1.4.1.12124.250.22.2.1 | current |
| storageCoalescedCrit NOTIFICATION-TYPE There are storage transport issues on a node | 1.3.6.1.4.1.12124.250.22.2.3 | current |
| storageCoalescedWarn NOTIFICATION-TYPE There are storage transport issues on a node | 1.3.6.1.4.1.12124.250.22.2.5 | current |
| cloudpoolNetworkErrorCrit NOTIFICATION-TYPE CloudPools network issues | 1.3.6.1.4.1.12124.250.23.1.3 | current |
| cloudpoolAuthenticationErrorCrit NOTIFICATION-TYPE CloudPools authentication issues | 1.3.6.1.4.1.12124.250.23.2.3 | current |
| cloudpoolAuthorizationErrorCrit NOTIFICATION-TYPE CloudPools authorization issues | 1.3.6.1.4.1.12124.250.23.3.3 | current |
| cloudpoolBucketNotFoundErrorCrit NOTIFICATION-TYPE CloudPools bucket not found issues | 1.3.6.1.4.1.12124.250.23.4.3 | current |
| cloudpoolObjectNotFoundErrorCrit NOTIFICATION-TYPE CloudPools Object not found issues | 1.3.6.1.4.1.12124.250.23.5.3 | current |
| cloudpoolDataCorruptionIntegrityErrorEmerg NOTIFICATION-TYPE CloudPools data corruption integrity emergency issues | 1.3.6.1.4.1.12124.250.23.6.1 | current |
| cloudpoolNoUsableAccountFoundErrorCrit NOTIFICATION-TYPE CloudPools no usable account found for the policy, cloudpool | 1.3.6.1.4.1.12124.250.23.7.3 | current |
| cloudpoolCertificateErrorCrit NOTIFICATION-TYPE CloudPools Certificate issues | 1.3.6.1.4.1.12124.250.23.8.3 | current |
| upgradeStartInfo NOTIFICATION-TYPE An upgrade or rollback has been started. | 1.3.6.1.4.1.12124.250.24.1.7 | current |
| upgradeFinishInfo NOTIFICATION-TYPE An upgrade or rollback has finished. | 1.3.6.1.4.1.12124.250.24.2.7 | current |
| upgradeClusterEventCrit NOTIFICATION-TYPE Upgrade cluster event. | 1.3.6.1.4.1.12124.250.24.3.3 | current |
| upgradeClusterEventWarn NOTIFICATION-TYPE Upgrade cluster event. | 1.3.6.1.4.1.12124.250.24.3.5 | current |
| upgradeClusterEventInfo NOTIFICATION-TYPE Upgrade cluster event. | 1.3.6.1.4.1.12124.250.24.3.7 | current |
| upgradeNodeEventCrit NOTIFICATION-TYPE Upgrade node event. | 1.3.6.1.4.1.12124.250.24.4.3 | current |
| upgradeNodeEventWarn NOTIFICATION-TYPE Upgrade node event. | 1.3.6.1.4.1.12124.250.24.4.5 | current |
| upgradeNodeEventInfo NOTIFICATION-TYPE Upgrade node event. | 1.3.6.1.4.1.12124.250.24.4.7 | current |
| upgradeRollbackStartInfo NOTIFICATION-TYPE Upgrade rollback start. | 1.3.6.1.4.1.12124.250.24.5.7 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| groupStateTrapsGroup NOTIFICATION-GROUP Collection of traps for group state. | 1.3.6.1.4.1.12124.250.51.1 | current |
| filesystemTrapsGroup NOTIFICATION-GROUP Collection of filesystem traps. | 1.3.6.1.4.1.12124.250.51.11 | current |
| smartQuotaTrapsGroup NOTIFICATION-GROUP Collection of smartQuota traps. | 1.3.6.1.4.1.12124.250.51.12 | current |
| snapshotTrapsGroup NOTIFICATION-GROUP Collection of snapshot traps. | 1.3.6.1.4.1.12124.250.51.13 | current |
| syncIQTrapsGroup NOTIFICATION-GROUP Collection of syncIQ traps. | 1.3.6.1.4.1.12124.250.51.14 | current |
| softwareTrapsGroup NOTIFICATION-GROUP Collection of software traps. | 1.3.6.1.4.1.12124.250.51.15 | current |
| avscanTrapsGroup NOTIFICATION-GROUP Collection of avscan traps. | 1.3.6.1.4.1.12124.250.51.16 | current |
| netProtoTrapsGroup NOTIFICATION-GROUP Collection of net protocol traps. | 1.3.6.1.4.1.12124.250.51.17 | current |
| networkingTrapsGroup NOTIFICATION-GROUP Collection of networking traps. | 1.3.6.1.4.1.12124.250.51.18 | current |
| hardwareTrapsGroup NOTIFICATION-GROUP Collection of sensor traps. | 1.3.6.1.4.1.12124.250.51.19 | current |
| systemDiskTrapsGroup NOTIFICATION-GROUP Collection of system disk traps. | 1.3.6.1.4.1.12124.250.51.20 | current |
| sensorTrapsGroup NOTIFICATION-GROUP Collection of sensor traps. | 1.3.6.1.4.1.12124.250.51.21 | current |
| storageTransportTrapsGroup NOTIFICATION-GROUP Collection of storage transport traps. | 1.3.6.1.4.1.12124.250.51.22 | current |
| cloudPoolsTrapsGroup NOTIFICATION-GROUP Collection of cloud pools traps. | 1.3.6.1.4.1.12124.250.51.23 | current |
| upgradeTrapsGroup NOTIFICATION-GROUP Collection of upgrade traps. | 1.3.6.1.4.1.12124.250.51.24 | current |
| variablesGroup OBJECT-GROUP Collection of variable traps. | 1.3.6.1.4.1.12124.250.51.50 | current |
| trapGroupCompliance MODULE-COMPLIANCE Compliance statement for the Isilon traps. | 1.3.6.1.4.1.12124.250.52.1 | current |