IRT-FM-DUALDRIVE-MIB
- Registered at
- 1.3.6.1.4.1.19831.1.1.3.4
- Last updated
- 2007-05-04 14:00
- Organization
- IRT for WORKING-GROUP-TC-MIB
- Revisions
- 2007-05-04 14:00, 2006-12-20 14:00, 2006-09-21 14:00, 2006-09-19 14:00, 2006-09-07 14:00
- Namespace
- irt
- Source file
IRT-FM-DUALDRIVE-MIB- Digest
sha256:78eeddcf8645456e3a56dbf9468fc44ba8ea7389311c6ec26373b69ea6b68f29
Description
Description. branch definition 1st level events OBJECT IDENTIFIER ::= { fmDualDrive 0 } fmDDGeneral OBJECT IDENTIFIER ::= { fmDualDrive 1 } fmDDExciterA OBJECT IDENTIFIER ::= { fmDualDrive 2 } fmDDExciterB OBJECT IDENTIFIER ::= { fmDualDrive 3 } fmDDEventEnable OBJECT IDENTIFIER ::= { fmDualDrive 4 } fmDDEventPriority OBJECT IDENTIFIER ::= { fmDualDrive 5 } groups OBJECT IDENTIFIER ::= { fmDualDrive 6 } 2nd level fmDDEventEnableGeneral OBJECT IDENTIFIER ::= { fmDDEventEnable 1 } fmDDEventEnableExciterA OBJECT IDENTIFIER ::= { fmDDEventEnable 2 } fmDDEventEnableExciterB OBJECT IDENTIFIER ::= { fmDDEventEnable 3 } fmDDEventPriorityGeneral OBJECT IDENTIFIER ::= { fmDDEventPriority 1 } fmDDEventPriorityExciterA OBJECT IDENTIFIER ::= { fmDDEventPriority 2 } fmDDEventPriorityExciterB OBJECT IDENTIFIER ::= { fmDDEventPriority 3 } end branch
Contact
Andreas Metz Institut fuer Rundfunktechnik GmbH Broadcast Networks and Servers (SN) Floriansmuehlstr.60 80939 Munich Germany Phone: +49 89 32399 325 Fax: +49 89 32399 354
Imports
| From | Symbols |
|---|---|
| IRT-COMMONVARBINDS-MIB | eventCounter, eventPriority, eventTimeStamp, mibRelease |
| IRT-TRANSMITTER-SMI-MIB | ExecutedNotExecuted, FaultOK, LocalRemote, PresentNotPresent, ReadyNotReady, SelectManualAuto, SelectOnOff, WarningOK, fm |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-MIB | sysDescr, sysLocation, sysName |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IRT-COMMONVARBINDS-MIB IRT-FM-DUALDRIVE-MIB IRT-TRANSMITTER-SMI-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| fmEventsDD OBJECT-IDENTITY | 1.3.6.1.4.1.19831.1.1.3.4.0 | |||
| fmDDGeneral OBJECT-IDENTITY | 1.3.6.1.4.1.19831.1.1.3.4.1 | |||
| fmDDPreselectionExciter OBJECT-TYPE fm. Preselection of the exciter | 1.3.6.1.4.1.19831.1.1.3.4.1.1 | INTEGER {undefined(0), exciterA(1), exciterB(2)} | read-write | current |
| fmDDTransmitterOpMode OBJECT-TYPE Dual drive. Operation mode of main exciter (0) undefined (1) ON (2) OFF | 1.3.6.1.4.1.19831.1.1.3.4.1.2 | SelectOnOff | read-write | current |
| fmDDReserveControl OBJECT-TYPE Dual drive. Operation mode of reserve exciter (0) undefined (1) ON (2) OFF | 1.3.6.1.4.1.19831.1.1.3.4.1.3 | SelectOnOff | read-write | current |
| fmDDRFPresent OBJECT-TYPE Dual drive. Output power is present (0) undefined (1) present (2) not present | 1.3.6.1.4.1.19831.1.1.3.4.1.4 | PresentNotPresent | read-only | current |
| fmDDAmplifierFault OBJECT-TYPE Dual drive. Fault state of amplifier (0) undefined (1) fault (2) ok | 1.3.6.1.4.1.19831.1.1.3.4.1.5 | FaultOK | read-only | current |
| fmDDAmplifierWarning OBJECT-TYPE Dual drive. Warning state of amplifier (0) undefined (1) warning (2) ok | 1.3.6.1.4.1.19831.1.1.3.4.1.6 | WarningOK | read-only | current |
| fmDDActiveExciter OBJECT-TYPE Dual drive. Active exciter | 1.3.6.1.4.1.19831.1.1.3.4.1.7 | INTEGER {undefined(0), exciterA(1), exciterB(2)} | read-only | current |
| fmDDLocalMode OBJECT-TYPE Dual drive. Local mode (0) undefined (1) local (2) remote | 1.3.6.1.4.1.19831.1.1.3.4.1.8 | LocalRemote | read-only | current |
| fmDDControlUnitFault OBJECT-TYPE Dual drive. State of the control unit (0) undefined (1) fault (2) ok | 1.3.6.1.4.1.19831.1.1.3.4.1.9 | FaultOK | read-only | current |
| fmDDSwitchOverMode OBJECT-TYPE Dual drive. Switch over mode: manual or automatic (0) undefined (1) manual (2) automatic | 1.3.6.1.4.1.19831.1.1.3.4.1.10 | SelectManualAuto | read-write | current |
| fmDDSwitchOverReady OBJECT-TYPE Dual drive. State of the dual drive switch over unit (0) undefined (1) ready (2) not ready | 1.3.6.1.4.1.19831.1.1.3.4.1.11 | ReadyNotReady | read-only | current |
| fmDDSwitchOverExecuted OBJECT-TYPE Dual drive. Showsif the reserve switch over unit it has executed (0) undefined (1) executed (2) not executed | 1.3.6.1.4.1.19831.1.1.3.4.1.12 | ExecutedNotExecuted | read-only | current |
| fmDDSwitchOverFault OBJECT-TYPE Dual drive. fault state of the switsch over unit (0) undefined (1) faulty (2) ok | 1.3.6.1.4.1.19831.1.1.3.4.1.13 | FaultOK | read-only | current |
| fmDDExciterA OBJECT-IDENTITY | 1.3.6.1.4.1.19831.1.1.3.4.2 | |||
| fmDDExciterALocalMode OBJECT-TYPE Dual drive. Local mode of exciter A (0) undefined (1) local (2) remote | 1.3.6.1.4.1.19831.1.1.3.4.2.1 | LocalRemote | read-only | current |
| fmDDExciterAFault OBJECT-TYPE Dual drive. Fault state of exciter A (0) undefined (1) fault (2) ok | 1.3.6.1.4.1.19831.1.1.3.4.2.2 | FaultOK | read-only | current |
| fmDDExciterAWarning OBJECT-TYPE Dual drive.Warning state of exciter A (0) undefined (1) warning (2) ok | 1.3.6.1.4.1.19831.1.1.3.4.2.3 | WarningOK | read-only | current |
| fmDDExciterB OBJECT-IDENTITY | 1.3.6.1.4.1.19831.1.1.3.4.3 | |||
| fmDDExciterBLocalMode OBJECT-TYPE Dual drive. Local mode of exciter B (0) undefined (1) local (2) remote | 1.3.6.1.4.1.19831.1.1.3.4.3.1 | LocalRemote | read-only | current |
| fmDDExciterBFault OBJECT-TYPE Dual drive. Fault state of exciter B (0) undefined (1) fault (2) ok | 1.3.6.1.4.1.19831.1.1.3.4.3.2 | FaultOK | read-only | current |
| fmDDExciterBWarning OBJECT-TYPE Dual drive. Warning state of exciter B (0) undefined (1) warning (2) ok | 1.3.6.1.4.1.19831.1.1.3.4.3.3 | WarningOK | read-only | current |
| fmDDEventEnable OBJECT-IDENTITY | 1.3.6.1.4.1.19831.1.1.3.4.4 | |||
| fmDDEventEnableGeneral OBJECT-IDENTITY | 1.3.6.1.4.1.19831.1.1.3.4.4.1 | |||
| fmDDPreselectionExciterEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDPreselectionExciter | 1.3.6.1.4.1.19831.1.1.3.4.4.1.1 | TruthValue | read-write | current |
| fmDDTransmitterOpModeEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDTransmitterOpMode event | 1.3.6.1.4.1.19831.1.1.3.4.4.1.2 | TruthValue | read-write | current |
| fmDDReserveControlEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDIReserveControl event | 1.3.6.1.4.1.19831.1.1.3.4.4.1.3 | TruthValue | read-write | current |
| fmDDRFPresentEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDRFPresent event | 1.3.6.1.4.1.19831.1.1.3.4.4.1.4 | TruthValue | read-write | current |
| fmDDAmplifierFaultEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDAmplifierFault event | 1.3.6.1.4.1.19831.1.1.3.4.4.1.5 | TruthValue | read-write | current |
| fmDDAmplifierWarningEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDAmplifierWarning event | 1.3.6.1.4.1.19831.1.1.3.4.4.1.6 | TruthValue | read-write | current |
| fmDDActiveExciterEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDActiveExciter event | 1.3.6.1.4.1.19831.1.1.3.4.4.1.7 | TruthValue | read-write | current |
| fmDDLocalModeEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDLocalMode event | 1.3.6.1.4.1.19831.1.1.3.4.4.1.8 | TruthValue | read-write | current |
| fmDDControlUnitFaultEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDControlUnitFault event | 1.3.6.1.4.1.19831.1.1.3.4.4.1.9 | TruthValue | read-write | current |
| fmDDSwitchOverModeEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDSwitchOverMode event | 1.3.6.1.4.1.19831.1.1.3.4.4.1.10 | TruthValue | read-write | current |
| fmDDSwitchOverReadyEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDSwitchOverReady event | 1.3.6.1.4.1.19831.1.1.3.4.4.1.11 | TruthValue | read-write | current |
| fmDDSwitchOverExecutedEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDSwitchOverExecuted event | 1.3.6.1.4.1.19831.1.1.3.4.4.1.12 | TruthValue | read-write | current |
| fmDDSwitchOverFaultEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDSwitchOverFault event | 1.3.6.1.4.1.19831.1.1.3.4.4.1.13 | TruthValue | read-write | current |
| fmDDEventEnableExciterA OBJECT-IDENTITY | 1.3.6.1.4.1.19831.1.1.3.4.4.2 | |||
| fmDDExciterALocalModeEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDExciterALocalMode event | 1.3.6.1.4.1.19831.1.1.3.4.4.2.1 | TruthValue | read-write | current |
| fmDDExciterAFaultEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDExciterAFault event | 1.3.6.1.4.1.19831.1.1.3.4.4.2.2 | TruthValue | read-write | current |
| fmDDExciterAWarningEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDExciterAWarning event | 1.3.6.1.4.1.19831.1.1.3.4.4.2.3 | TruthValue | read-write | current |
| fmDDEventEnableExciterB OBJECT-IDENTITY | 1.3.6.1.4.1.19831.1.1.3.4.4.3 | |||
| fmDDExciterBLocalModeEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDExciterBLocalMode event | 1.3.6.1.4.1.19831.1.1.3.4.4.3.1 | TruthValue | read-write | current |
| fmDDExciterBFaultEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDExciterBFault event | 1.3.6.1.4.1.19831.1.1.3.4.4.3.2 | TruthValue | read-write | current |
| fmDDExciterBWarningEnable OBJECT-TYPE Description. Enable/Disable switch for fmDDExciterBWarning event | 1.3.6.1.4.1.19831.1.1.3.4.4.3.3 | TruthValue | read-write | current |
| fmDDEventPriority OBJECT-IDENTITY | 1.3.6.1.4.1.19831.1.1.3.4.5 | |||
| fmDDEventPriorityGeneral OBJECT-IDENTITY | 1.3.6.1.4.1.19831.1.1.3.4.5.1 | |||
| fmDDPreselectionExciterPriority OBJECT-TYPE Description. Priority for fmDDPreselectionExciter event | 1.3.6.1.4.1.19831.1.1.3.4.5.1.1 | Unsigned32 | read-write | current |
| fmDDTransmitterOpModePriority OBJECT-TYPE Description. Priority for fmDDTransmitterOpMode event | 1.3.6.1.4.1.19831.1.1.3.4.5.1.2 | Unsigned32 | read-write | current |
| fmDDReserveControlPriority OBJECT-TYPE Description. Priority for fmDDReserveControl event | 1.3.6.1.4.1.19831.1.1.3.4.5.1.3 | Unsigned32 | read-write | current |
| fmDDRFPresentPriority OBJECT-TYPE Description. Priority for fmDDRFPresent event | 1.3.6.1.4.1.19831.1.1.3.4.5.1.4 | Unsigned32 | read-write | current |
| fmDDAmplifierFaultPriority OBJECT-TYPE Description. Priority for fmDDAmplifierFault event | 1.3.6.1.4.1.19831.1.1.3.4.5.1.5 | Unsigned32 | read-write | current |
| fmDDAmplifierWarningPriority OBJECT-TYPE Description. Priority for fmDDAmplifierWarning event | 1.3.6.1.4.1.19831.1.1.3.4.5.1.6 | Unsigned32 | read-write | current |
| fmDDActiveExciterPriority OBJECT-TYPE Description. Priority for fmDDActiveExciter event | 1.3.6.1.4.1.19831.1.1.3.4.5.1.7 | Unsigned32 | read-write | current |
| fmDDLocalModePriority OBJECT-TYPE Description. Priority for fmDDLocalMode event | 1.3.6.1.4.1.19831.1.1.3.4.5.1.8 | Unsigned32 | read-write | current |
| fmDDControlUnitFaultPriority OBJECT-TYPE Description. Priority for fmDDControlUnitFault event | 1.3.6.1.4.1.19831.1.1.3.4.5.1.9 | Unsigned32 | read-write | current |
| fmDDSwitchOverModePriority OBJECT-TYPE Description. Priority for fmDDSwitchOverMode event | 1.3.6.1.4.1.19831.1.1.3.4.5.1.10 | Unsigned32 | read-write | current |
| fmDDSwitchOverReadyPriority OBJECT-TYPE Description. Priority for fmDDSwitchOverReady event | 1.3.6.1.4.1.19831.1.1.3.4.5.1.11 | Unsigned32 | read-write | current |
| fmDDSwitchOverExecutedPriority OBJECT-TYPE Description. Priority for fmDDSwitchOverExecuted event | 1.3.6.1.4.1.19831.1.1.3.4.5.1.12 | Unsigned32 | read-write | current |
| fmDDSwitchOverFaultPriority OBJECT-TYPE Description. Priority for fmDDSwitchOverFault event | 1.3.6.1.4.1.19831.1.1.3.4.5.1.13 | Unsigned32 | read-write | current |
| fmDDEventPriorityExciterA OBJECT-IDENTITY | 1.3.6.1.4.1.19831.1.1.3.4.5.2 | |||
| fmDDExciterALocalModePriority OBJECT-TYPE Description. Priority for fmDDExciterALocalMode event event | 1.3.6.1.4.1.19831.1.1.3.4.5.2.1 | Unsigned32 | read-write | current |
| fmDDExciterAFaultPriority OBJECT-TYPE Description. Priority for fmDDExciterAFault event | 1.3.6.1.4.1.19831.1.1.3.4.5.2.2 | Unsigned32 | read-write | current |
| fmDDExciterAWarningPriority OBJECT-TYPE Description. Priority for fmDDExciterAWarning event | 1.3.6.1.4.1.19831.1.1.3.4.5.2.3 | Unsigned32 | read-write | current |
| fmDDEventPriorityExciterB OBJECT-IDENTITY | 1.3.6.1.4.1.19831.1.1.3.4.5.3 | |||
| fmDDExciterBLocalModePriority OBJECT-TYPE Description. Priority for fmDDExciterBLocalMode event event | 1.3.6.1.4.1.19831.1.1.3.4.5.3.1 | Unsigned32 | read-write | current |
| fmDDExciterBFaultPriority OBJECT-TYPE Description. Priority for fmDDExciterBFault event | 1.3.6.1.4.1.19831.1.1.3.4.5.3.2 | Unsigned32 | read-write | current |
| fmDDExciterBWarningPriority OBJECT-TYPE Description. Priority for fmDDExciterBWarning event | 1.3.6.1.4.1.19831.1.1.3.4.5.3.3 | Unsigned32 | read-write | current |
| groupsDD OBJECT-IDENTITY | 1.3.6.1.4.1.19831.1.1.3.4.6 | |||
| complianceDD OBJECT-IDENTITY | 1.3.6.1.4.1.19831.1.1.3.4.7 |
Notifications
| Name | OID | Status |
|---|---|---|
| fmDDPreselectionExciterEvent NOTIFICATION-TYPE Description. fmDDPreselectionExciterEvent notification | 1.3.6.1.4.1.19831.1.1.3.4.0.1 | current |
| fmDDTransmitterOpModeEvent NOTIFICATION-TYPE Description. fmDDTransmitterOpMode notification | 1.3.6.1.4.1.19831.1.1.3.4.0.2 | current |
| fmDDReserveControlEvent NOTIFICATION-TYPE Description. fmDDReserveControl nitification | 1.3.6.1.4.1.19831.1.1.3.4.0.3 | current |
| fmDDRFPresentEvent NOTIFICATION-TYPE Description. fmDDRFPresent notification | 1.3.6.1.4.1.19831.1.1.3.4.0.4 | current |
| fmDDAmplifierFaultEvent NOTIFICATION-TYPE Description. fmDDAmplifierFault notification | 1.3.6.1.4.1.19831.1.1.3.4.0.5 | current |
| fmDDAmplifierWarningEvent NOTIFICATION-TYPE Description. fmDDAmplifierWarning notification | 1.3.6.1.4.1.19831.1.1.3.4.0.6 | current |
| fmDDActiveExciterEvent NOTIFICATION-TYPE Description.fmDDActiveExciter notification | 1.3.6.1.4.1.19831.1.1.3.4.0.7 | current |
| fmDDLocalModeEvent NOTIFICATION-TYPE Description. fmDDLocalMode notification | 1.3.6.1.4.1.19831.1.1.3.4.0.8 | current |
| fmDDControlUnitFaultEvent NOTIFICATION-TYPE Description. fmDDControlUnitFault notification | 1.3.6.1.4.1.19831.1.1.3.4.0.9 | current |
| fmDDSwitchOverModeEvent NOTIFICATION-TYPE Description. fmDDSwitchOverMode notification | 1.3.6.1.4.1.19831.1.1.3.4.0.10 | current |
| fmDDSwitchOverReadyEvent NOTIFICATION-TYPE Description. fmDDSwitchOverReady notification | 1.3.6.1.4.1.19831.1.1.3.4.0.11 | current |
| fmDDSwitchOverExecutedEvent NOTIFICATION-TYPE Description. fmDDSwitchOverExecuted notification | 1.3.6.1.4.1.19831.1.1.3.4.0.12 | current |
| fmDDSwitchOverFaultEvent NOTIFICATION-TYPE Description. fmDDSwitchOverFault notification | 1.3.6.1.4.1.19831.1.1.3.4.0.13 | current |
| fmDDExciterALocalModeEvent NOTIFICATION-TYPE Description. fmDDExciterALocalMode notification | 1.3.6.1.4.1.19831.1.1.3.4.0.14 | current |
| fmDDExciterAFaultEvent NOTIFICATION-TYPE Description. fmDDExciterAFault notification | 1.3.6.1.4.1.19831.1.1.3.4.0.15 | current |
| fmDDExciterAWarningEvent NOTIFICATION-TYPE Description. fmDDExciterAWarning notification | 1.3.6.1.4.1.19831.1.1.3.4.0.16 | current |
| fmDDExciterBLocalModeEvent NOTIFICATION-TYPE Description. fmDDExciterBLocalMode notification | 1.3.6.1.4.1.19831.1.1.3.4.0.17 | current |
| fmDDExciterBFaultEvent NOTIFICATION-TYPE Description. fmDDExciterBFault notification | 1.3.6.1.4.1.19831.1.1.3.4.0.18 | current |
| fmDDExciterBWarningEvent NOTIFICATION-TYPE Description. fmDDExciterBWarning notification | 1.3.6.1.4.1.19831.1.1.3.4.0.19 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| eventGroupDD NOTIFICATION-GROUP Description. | 1.3.6.1.4.1.19831.1.1.3.4.6.1 | current |
| objectGroupDD OBJECT-GROUP Description.dual drive: object group | 1.3.6.1.4.1.19831.1.1.3.4.6.2 | current |
| fmDualDriveCompliance MODULE-COMPLIANCE Compliance Statement | 1.3.6.1.4.1.19831.1.1.3.4.7.1 | current |