MIBs Depot

IEEE8023-DOT3-LLDP-EXT-V2-MIB

Registered at
1.3.111.2.802.3.1.5
Last updated
2013-04-11 00:00
Organization
IEEE 802.3 Working Group
Revisions
2013-04-11 00:00, 2011-02-02 00:00
Namespace
standard
Source file
IEEE8023-DOT3-LLDP-EXT-V2-MIB
Digest
sha256:0dc4dccf365cc5de6f70b6f04b1925fcd2c995b7720113c4866bf8ededcee845

Description

The LLDP Management Information Base extension module for IEEE 802.3 organizationally defined discovery information.

Contact

WG-URL: http://www.ieee802.org/3/index.html WG-EMail: STDS-802-3-MIB@LISTSERV.IEEE.ORG Contact: Howard Frazier Postal: 3151 Zanker Road San Jose, CA 95134 USA Tel: +1.408.922.8164 E-mail: hfrazier@broadcom.com

Imports

FromSymbols
IF-MIBifGeneralInformationGroup
LLDP-V2-MIBlldpV2LocPortIfIndex, lldpV2PortConfigEntry, lldpV2RemIndex, lldpV2RemLocalDestMACAddress, lldpV2RemLocalIfIndex, lldpV2RemTimeMark
LLDP-V2-TC-MIBLldpV2PowerPortClass
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMIInteger32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso, org
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANA-ADDRESS-FAMILY-NUMBERS-MIB
IANAifType-MIB
IEEE8023-DOT3-LLDP-EXT-V2-MIB
IF-MIB
LLDP-V2-MIB
LLDP-V2-TC-MIB
RFC1158-MIB
RFC1271-MIB
RMON-MIB
RMON2-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC
TOKEN-RING-RMON-MIB

Objects

NameOIDSyntaxAccessStatus
lldpV2Xdot3Objects
OBJECT-IDENTITY
1.3.111.2.802.3.1.5.1
lldpV2Xdot3Config
OBJECT-IDENTITY
1.3.111.2.802.3.1.5.1.1
lldpV2Xdot3PortConfigTable
OBJECT-TYPE
A table that controls selection of LLDP TLVs to be transmitted on individual ports.
1.3.111.2.802.3.1.5.1.1.1not-accessiblecurrent
lldpV2Xdot3PortConfigEntry
OBJECT-TYPE
LLDP configuration information that controls the transmission of IEEE 802.3 organizationally defined TLVs on LLDP transmission capable ports. This configuration object augments the lldpV2PortConfigEntry of the LLDP-MIB, therefore it is only present along with the port configuration defined by the associated lldpV2PortConfigEntry entry. Each active lldpV2Xdot3PortConfigEntry is restored from non-volatile storage (along with the corresponding lldpV2PortConfigEntry) after a re-initialization of the management system.
1.3.111.2.802.3.1.5.1.1.1.1not-accessiblecurrent
lldpV2Xdot3PortConfigTLVsTxEnable
OBJECT-TYPE
The lldpV2Xdot3PortConfigTLVsTxEnable, defined as a bitmap, includes the IEEE 802.3 organizationally defined set of LLDP TLVs whose transmission is allowed by the local LLDP agent by the network management. Each bit in the bitmap corresponds to an IEEE 802.3 subtype associated with a specific IEEE 802.3 optional TLV. The bit 'macPhyConfigStatus(0)' indicates that the LLDP agent should transmit 'MAC/PHY configuration/status TLV'. The bit 'powerViaMDI(1)' indicates that the LLDP agent should transmit 'Power via MDI TLV'. The bit 'unused(2)' is no longer used; this was used for the 'Link Aggregation TLV' in the previous version. The bit 'maxFrameSize(3)' indicates that the LLDP agent should transmit 'Maximum-frame-size TLV'. The default value for lldpV2Xdot3PortConfigTLVsTxEnable object is an empty set, which means no enumerated values are set. The value of this object is restored from non-volatile storage after a re-initialization of the management system.
1.3.111.2.802.3.1.5.1.1.1.1.1Bits {macPhyConfigStatus(0), powerViaMDI(1), unused(2), maxFrameSize(3)}read-writecurrent
lldpV2Xdot3LocalData
OBJECT-IDENTITY
1.3.111.2.802.3.1.5.1.2
lldpV2Xdot3LocPortTable
OBJECT-TYPE
This table contains one row per port of Ethernet port information (as a part of the LLDP 802.3 organizational extension) on the local system known to this agent.
1.3.111.2.802.3.1.5.1.2.1not-accessiblecurrent
lldpV2Xdot3LocPortEntry
OBJECT-TYPE
Information about a particular port component.
1.3.111.2.802.3.1.5.1.2.1.1not-accessiblecurrent
lldpV2Xdot3LocPortAutoNegSupported
OBJECT-TYPE
The truth value used to indicate whether the given port (associated with the local system) supports Auto-negotiation.
1.3.111.2.802.3.1.5.1.2.1.1.1TruthValueread-onlycurrent
lldpV2Xdot3LocPortAutoNegEnabled
OBJECT-TYPE
The truth value used to indicate whether port Auto-negotiation is enabled on the given port associated with the local system.
1.3.111.2.802.3.1.5.1.2.1.1.2TruthValueread-onlycurrent
lldpV2Xdot3LocPortAutoNegAdvertisedCap
OBJECT-TYPE
This object contains the value (bitmap) of the ifMauAutoNegCapAdvertisedBits object (defined in IETF RFC 3636) which is associated with the given port on the local system.
1.3.111.2.802.3.1.5.1.2.1.1.3OCTET STRING (SIZE(2))read-onlycurrent
lldpV2Xdot3LocPortOperMauType
OBJECT-TYPE
An integer value that indicates the operational MAU type of the given port on the local system. This object contains the integer value derived from the list position of the corresponding dot3MauType as listed in Clause 13 and is equal to the last number in the respective dot3MauType OID. For example, if the ifMauType object is dot3MauType1000BaseTHD which corresponds to {dot3MauType 29}, the numerical value of this field is 29. For MAU types not listed in Clause 13, the value of this field shall be set to zero.
1.3.111.2.802.3.1.5.1.2.1.1.4Unsigned32 (0..2147483647)read-onlycurrent
lldpV2Xdot3LocPowerTable
OBJECT-TYPE
This table contains one row per port of power Ethernet information (as a part of the LLDP IEEE 802.3 organizational extension) on the local system known to this agent.
1.3.111.2.802.3.1.5.1.2.2not-accessiblecurrent
lldpV2Xdot3LocPowerEntry
OBJECT-TYPE
Information about a particular port component.
1.3.111.2.802.3.1.5.1.2.2.1not-accessiblecurrent
lldpV2Xdot3LocPowerPortClass
OBJECT-TYPE
The value that identifies the port Class of the given port associated with the local system.
1.3.111.2.802.3.1.5.1.2.2.1.1LldpV2PowerPortClassread-onlycurrent
lldpV2Xdot3LocPowerMDISupported
OBJECT-TYPE
The truth value used to indicate whether the MDI power is supported on the given port associated with the local system.
1.3.111.2.802.3.1.5.1.2.2.1.2TruthValueread-onlycurrent
lldpV2Xdot3LocPowerMDIEnabled
OBJECT-TYPE
The truth value used to identify whether MDI power is enabled on the given port associated with the local system.
1.3.111.2.802.3.1.5.1.2.2.1.3TruthValueread-onlycurrent
lldpV2Xdot3LocPowerPairControlable
OBJECT-TYPE
The truth value is derived from the value of pethPsePortPowerPairsControlAbility object (defined in Clause 8) and is used to indicate whether the pair selection can be controlled on the given port associated with the local system.
1.3.111.2.802.3.1.5.1.2.2.1.4TruthValueread-onlycurrent
lldpV2Xdot3LocPowerPairs
OBJECT-TYPE
This object contains the value of the pethPsePortPowerPairs object (defined in Clause 8) which is associated with the given port on the local system.
1.3.111.2.802.3.1.5.1.2.2.1.5Unsigned32 (1 | 2)read-onlycurrent
lldpV2Xdot3LocPowerClass
OBJECT-TYPE
This object contains the value of the pethPsePortPowerClassifications object (defined in Clause 8) which is associated with the given port on the local system.
1.3.111.2.802.3.1.5.1.2.2.1.6Unsigned32 (1 | 2 | 3 | 4 | 5)read-onlycurrent
lldpV2Xdot3LocPowerType
OBJECT-TYPE
A GET returns an integer indicating whether the local system is a PSE or a PD and whether it is Type 1 or Type 2.
1.3.111.2.802.3.1.5.1.2.2.1.7INTEGER {psetype1(0), psetype2(1), pdtype(2), pdtype2(3)}read-onlycurrent
lldpV2Xdot3LocPowerSource
OBJECT-TYPE
A GET returns an integer indicating the power sources of the local system. A PSE indicates whether it is being powered by a primary power source; a backup power source; or unknown. A PD indicates whether it is being powered by a PSE and locally; by a PSE only; or unknown.
1.3.111.2.802.3.1.5.1.2.2.1.8INTEGER {pseprimary(0), psebackup(1), pseunknown(2), pdpseandlocal(3), pdpseonly(4), pdunknown(5)}read-onlycurrent
lldpV2Xdot3LocPowerPriority
OBJECT-TYPE
A GET returns the priority of a PD system. For a PSE, this is the priority that the PSE assigns to the PD. For a PD, this is the priority that the PD requests from the PSE. A SET operation changes the priority of the PD system to the indicated value.
1.3.111.2.802.3.1.5.1.2.2.1.9INTEGER {low(0), high(1), critical(2), unknown(3)}read-writecurrent
lldpV2Xdot3LocPDRequestedPowerValue
OBJECT-TYPE
A GET returns the PD requested power value. For a PD, it is the power value that the PD has currently requested from the remote system. PD requested power value is the maximum input average power the PD ever draws under this power allocation if accepted. For a PSE, it is the power value that the PSE mirrors back to the remote system. This is the PD requested power value that was used by the PSE to compute the power it has currently allocated to the remote system. The PD requested power value is encoded according to IEEE Std 802.3 Equation (79?1), where X is the decimal value of aLldpXdot3LocPDRequestedPowerValue.
1.3.111.2.802.3.1.5.1.2.2.1.10Integer32read-onlycurrent
lldpV2Xdot3LocPSEAllocatedPowerValue
OBJECT-TYPE
A GET returns the PSE allocated power value. For a PSE, it is the power value that the PSE has currently allocated to the remote system. The PSE allocated power value is the maximum input average power that the PSE wants the PD to ever draw under this allocation if it is accepted. For a PD, it is the power value that the PD mirrors back to the remote system. This is the PSE allocated power value that was used by the PD to compute the power that it has currently requested from the remote system. The PSE allocated power value is encoded according to IEEE Std 802.3 Equation (79?2), where X is the decimal value of aLldpXdot3LocPSEAllocatedPowerValue.
1.3.111.2.802.3.1.5.1.2.2.1.11Integer32read-onlycurrent
lldpV2Xdot3LocResponseTime
OBJECT-TYPE
A GET returns the response time in seconds of the local system. For a PD, it is the maximum time required to update the value of lldpV2Xdot3LocPDRequestedPowerValue when the remote system requests the PD to change its max power draw. For a PSE, it is the maximum time required to update the value of lldpV2Xdot3LocPDRequestedPowerValue when the remote system requests of the PSE a new power value.
1.3.111.2.802.3.1.5.1.2.2.1.12Integer32read-onlycurrent
lldpV2Xdot3LocReady
OBJECT-TYPE
The truth value used to identify whether the local Data Link Layer classification engine has completed initialization and is ready to receive and transmit LLDPDUs.
1.3.111.2.802.3.1.5.1.2.2.1.13TruthValueread-onlycurrent
lldpV2Xdot3LocReducedOperationPowerValue
OBJECT-TYPE
A GET returns the reduced operation power value. For a PD, it is a power value that is lower than the currently requested power value. This reduced operation power value represents a power state in which the PD could continue to operate, but with less functionality than at the current PD requested power value. The PSE could optionally use this information in the event that the PSE subsequently requests a lower PD power value than the PD requested power value. For a PSE, it is a power value that the PSE could ask the PD to move to if the PSE wants the PD to move to a lower power state. The definition and encoding of PD requested power value is the same as described in lldpV2Xdot3LocPDRequestedPowerValue. The default value for this field is the hexadecimal value FFFF
1.3.111.2.802.3.1.5.1.2.2.1.14Integer32read-onlycurrent
lldpV2Xdot3LocMaxFrameSizeTable
OBJECT-TYPE
This table contains one row per port of maximum frame size information (as a part of the LLDP IEEE 802.3 organizational extension) on the local system known to this agent.
1.3.111.2.802.3.1.5.1.2.3not-accessiblecurrent
lldpV2Xdot3LocMaxFrameSizeEntry
OBJECT-TYPE
Maximum Frame Size information about a particular port component.
1.3.111.2.802.3.1.5.1.2.3.1not-accessiblecurrent
lldpV2Xdot3LocMaxFrameSize
OBJECT-TYPE
An integer value indicating the maximum supported frame size in octets on the given port of the local system.
1.3.111.2.802.3.1.5.1.2.3.1.1Unsigned32 (0..65535)read-onlycurrent
lldpV2Xdot3LocEEETable
OBJECT-TYPE
This table contains one row per port of Energy Efficient Ethernet information (as a part of the LLDP IEEE 802.3 organizational extension) on the local system known to this agent.
1.3.111.2.802.3.1.5.1.2.4not-accessiblecurrent
lldpV2Xdot3LocEEEEntry
OBJECT-TYPE
Information about a particular port component.
1.3.111.2.802.3.1.5.1.2.4.1not-accessiblecurrent
lldpV2Xdot3LocTxTwSys
OBJECT-TYPE
A GET returns the value of Tw_sys_tx that the local system can support in the transmit direction. This object maps to the variable LocTxSystemValue as defined in IEEE Std 802.3 78.4.2.3.
1.3.111.2.802.3.1.5.1.2.4.1.1Integer32read-onlycurrent
lldpV2Xdot3LocTxTwSysEcho
OBJECT-TYPE
A GET returns the value of Tw_sys_tx that the remote system is advertising that it can support in the transmit direction and is echoed by the local system under the control of the EEE DLL receiver state diagram. This object maps to the variable LocTxSystemValueEcho as defined in IEEE Std 802.3 78.4.2.3
1.3.111.2.802.3.1.5.1.2.4.1.2Integer32read-onlycurrent
lldpV2Xdot3LocRxTwSys
OBJECT-TYPE
A GET returns the value of Tw_sys_tx that the local system is requesting in the receive direction. This object maps to the variable LocRxSystemValue as defined in IEEE Std 802.3 78.4.2.3.
1.3.111.2.802.3.1.5.1.2.4.1.3Integer32read-onlycurrent
lldpV2Xdot3LocRxTwSysEcho
OBJECT-TYPE
A GET returns the value of Tw_sys_tx that the remote system is advertising that it is requesting in the receive direction and is echoed by the local system under the control of the EEE DLL transmitter state diagram. This object maps to the variable LocRxSystemValueEcho as defined in IEEE Std 802.3 78.4.2.3.
1.3.111.2.802.3.1.5.1.2.4.1.4Integer32read-onlycurrent
lldpV2Xdot3LocFbTwSys
OBJECT-TYPE
A GET returns the value of the fallback Tw_sys_tx that the local system is advertising to the remote system. This object maps to the variable LocFbSystemValue as defined in IEEE Std 802.3 78.4.2.3.
1.3.111.2.802.3.1.5.1.2.4.1.5Integer32read-onlycurrent
lldpV2Xdot3TxDllReady
OBJECT-TYPE
The truth value used to identify whether the local Data Link Layer EEE layer management function has completed initialization and is ready to receive and transmit LLDPDUs.
1.3.111.2.802.3.1.5.1.2.4.1.6TruthValueread-onlycurrent
lldpV2Xdot3RxDllReady
OBJECT-TYPE
The truth value used to identify whether the local Data Link Layer EEE layer management function has completed initialization and is ready to receive and transmit LLDPDUs.
1.3.111.2.802.3.1.5.1.2.4.1.7TruthValueread-onlycurrent
lldpV2Xdot3LocDllEnabled
OBJECT-TYPE
The truth value used to identify whether the local system has completed auto-negotiation with a link partner that has indicated at leat one EEE capability.
1.3.111.2.802.3.1.5.1.2.4.1.8TruthValueread-onlycurrent
lldpV2Xdot3RemoteData
OBJECT-IDENTITY
1.3.111.2.802.3.1.5.1.3
lldpV2Xdot3RemPortTable
OBJECT-TYPE
This table contains Ethernet port information (as a part of the LLDP IEEE 802.3 organizational extension) of the remote system.
1.3.111.2.802.3.1.5.1.3.1not-accessiblecurrent
lldpV2Xdot3RemPortEntry
OBJECT-TYPE
Information about a particular physical network connection.
1.3.111.2.802.3.1.5.1.3.1.1not-accessiblecurrent
lldpV2Xdot3RemPortAutoNegSupported
OBJECT-TYPE
The truth value used to indicate whether the given port (associated with remote system) supports Auto-negotiation.
1.3.111.2.802.3.1.5.1.3.1.1.1TruthValueread-onlycurrent
lldpV2Xdot3RemPortAutoNegEnabled
OBJECT-TYPE
The truth value used to indicate whether port Auto-negotiation is enabled on the given port associated with the remote system.
1.3.111.2.802.3.1.5.1.3.1.1.2TruthValueread-onlycurrent
lldpV2Xdot3RemPortAutoNegAdvertisedCap
OBJECT-TYPE
This object contains the value (bitmap) of the ifMauAutoNegCapAdvertisedBits object (defined in IETF RFC 3636) which is associated with the given port on the remote system.
1.3.111.2.802.3.1.5.1.3.1.1.3OCTET STRING (SIZE(2))read-onlycurrent
lldpV2Xdot3RemPortOperMauType
OBJECT-TYPE
An integer value that indicates the operational MAU type of the sending device. This object contains the integer value derived from the list position of the corresponding dot3MauType as listed in in Clause 13 and is equal to the last number in the respective dot3MauType OID. For example, if the ifMauType object is dot3MauType1000BaseTHD which corresponds to {dot3MauType 29}, the numerical value of this field is 29. For MAU types not listed in Clause 13, the value of this field shall be set to zero.
1.3.111.2.802.3.1.5.1.3.1.1.4Unsigned32 (0..2147483647)read-onlycurrent
lldpV2Xdot3RemPowerTable
OBJECT-TYPE
This table contains Ethernet power information (as a part of the LLDP IEEE 802.3 organizational extension) of the remote system.
1.3.111.2.802.3.1.5.1.3.2not-accessiblecurrent
lldpV2Xdot3RemPowerEntry
OBJECT-TYPE
Information about a particular physical network connection.
1.3.111.2.802.3.1.5.1.3.2.1not-accessiblecurrent
lldpV2Xdot3RemPowerPortClass
OBJECT-TYPE
The value that identifies the port Class of the given port associated with the remote system.
1.3.111.2.802.3.1.5.1.3.2.1.1LldpV2PowerPortClassread-onlycurrent
lldpV2Xdot3RemPowerMDISupported
OBJECT-TYPE
The truth value used to indicate whether the MDI power is supported on the given port associated with the remote system.
1.3.111.2.802.3.1.5.1.3.2.1.2TruthValueread-onlycurrent
lldpV2Xdot3RemPowerMDIEnabled
OBJECT-TYPE
The truth value used to identify whether MDI power is enabled on the given port associated with the remote system.
1.3.111.2.802.3.1.5.1.3.2.1.3TruthValueread-onlycurrent
lldpV2Xdot3RemPowerPairControlable
OBJECT-TYPE
The truth value is derived from the value of pethPsePortPowerPairsControlAbility object (defined in Clause 8) and is used to indicate whether the pair selection can be controlled on the given port associated with the remote system.
1.3.111.2.802.3.1.5.1.3.2.1.4TruthValueread-onlycurrent
lldpV2Xdot3RemPowerPairs
OBJECT-TYPE
This object contains the value of the pethPsePortPowerPairs object (defined in Clause 8) which is associated with the given port on the remote system.
1.3.111.2.802.3.1.5.1.3.2.1.5Unsigned32 (1 | 2)read-onlycurrent
lldpV2Xdot3RemPowerClass
OBJECT-TYPE
This object contains the value of the pethPsePortPowerClassifications object (defined in Clause 8) which is associated with the given port on the remote system.
1.3.111.2.802.3.1.5.1.3.2.1.6Unsigned32 (1 | 2 | 3 | 4 | 5)read-onlycurrent
lldpV2Xdot3RemPowerType
OBJECT-TYPE
A GET returns an integer indicating whether the remote system is a PSE or a PD and whether it is Type 1 or Type 2.
1.3.111.2.802.3.1.5.1.3.2.1.7INTEGER {psetype1(0), psetype2(1), pdtype(2), pdtype2(3)}read-onlycurrent
lldpV2Xdot3RemPowerSource
OBJECT-TYPE
A GET returns an integer indicating the power sources of the remote system. When the remote system is a PSE, it indicates whether it is being powered by a primary power source; a backup power source; or unknown. When the remote system is a PD, it indicates whether it is being powered by a PSE and locally; locally only; by a PSE only; or unknown.
1.3.111.2.802.3.1.5.1.3.2.1.8INTEGER {pseprimary(0), psebackup(1), pseunknown(2), pdpseandlocal(3), pdlocalonly(4), pdpseonly(5), pdunknown(6)}read-onlycurrent
lldpV2Xdot3RemPowerPriority
OBJECT-TYPE
A GET returns the priority of a PD system. For a PSE, this is the priority that the remote system requests. For a PD, this is the priority that the remote system has assigned.
1.3.111.2.802.3.1.5.1.3.2.1.9INTEGER {low(0), high(1), critical(2), unknown(3)}read-writecurrent
lldpV2Xdot3RemPDRequestedPowerValue
OBJECT-TYPE
A GET returns the PD requested power value that was used by the remote system to compute the power value that is has currently allocated to the PD. For a PSE, it is the PD requested power value received from the remote system. The definition and encoding of PD requested power value is the same as described in lldpV2Xdot3LocPDRequestedPowerValue.
1.3.111.2.802.3.1.5.1.3.2.1.10Integer32read-onlycurrent
lldpV2Xdot3RemPSEAllocatedPowerValue
OBJECT-TYPE
A GET returns the PSE allocated power value received from the remote system. For a PSE, it is the PSE allocated power value that was used by the remote system to compute the power value that it has currently requested from the PSE. For a PD, it is the PSE allocated power value received from the remote system. The definition and encoding of PSE allocated power value is the same as described in lldpV2Xdot3LocPSEAllocatedPowerValue.
1.3.111.2.802.3.1.5.1.3.2.1.11Integer32read-onlycurrent
lldpV2Xdot3RemMaxFrameSizeTable
OBJECT-TYPE
This table contains one row per port/destination address pair of maximum frame size information (as a part of the LLDP IEEE 802.3 organizational extension) of the remote system.
1.3.111.2.802.3.1.5.1.3.3not-accessiblecurrent
lldpV2Xdot3RemMaxFrameSizeEntry
OBJECT-TYPE
Maximum Frame Size information about a particular port component.
1.3.111.2.802.3.1.5.1.3.3.1not-accessiblecurrent
lldpV2Xdot3RemMaxFrameSize
OBJECT-TYPE
An integer value indicating the maximum supported frame size in octets on the port component associated with the remote system.
1.3.111.2.802.3.1.5.1.3.3.1.1Unsigned32 (0..65535)read-onlycurrent
lldpV2Xdot3RemEEETable
OBJECT-TYPE
This table contains one row per port of Energy Efficient Ethernet information (as a part of the LLDP IEEE 802.3 organizational extension) on the local system known to this agent.
1.3.111.2.802.3.1.5.1.3.4not-accessiblecurrent
lldpV2Xdot3RemEEEEntry
OBJECT-TYPE
Information about a particular port component.
1.3.111.2.802.3.1.5.1.3.4.1not-accessiblecurrent
lldpV2Xdot3RemTxTwSys
OBJECT-TYPE
A GET returns the value of Tw_sys_tx that the remote system can support in the transmit direction. This object maps to the variable RemTxSystemValue as defined in IEEE Std 802.3 78.4.2.3.
1.3.111.2.802.3.1.5.1.3.4.1.1Integer32read-onlycurrent
lldpV2Xdot3RemTxTwSysEcho
OBJECT-TYPE
A GET returns the value of Tw_sys_tx that the local system is advertising that it can support in the transmit direction as echoed by the remote system under the control of the EEE DLL receiver state diagram. This object maps to the variable RemTxSystemValueEcho as defined in IEEE Std 802.3 78.4.2.3
1.3.111.2.802.3.1.5.1.3.4.1.2Integer32read-onlycurrent
lldpV2Xdot3RemRxTwSys
OBJECT-TYPE
A GET returns the value of Tw_sys_tx that the remote system is requesting in the receive direction. This object maps to the variable RemRxSystemValue as defined in IEEE Std 802.3 78.4.2.3.
1.3.111.2.802.3.1.5.1.3.4.1.3Integer32read-onlycurrent
lldpV2Xdot3RemRxTwSysEcho
OBJECT-TYPE
A GET returns the value of Tw_sys_tx that the local system is advertising that it is requesting in the receive direction and is echoed by the remote system under the control of the EEE DLL transmitter state diagram. This object maps to the variable RemRxSystemValueEcho as defined in IEEE Std 802.3 78.4.2.3.
1.3.111.2.802.3.1.5.1.3.4.1.4Integer32read-onlycurrent
lldpV2Xdot3RemFbTwSys
OBJECT-TYPE
A GET returns the value of the fallback Tw_sys_tx that the remote system is advertising. This object maps to the variable RemFbSystemValue as defined in IEEE Std 802.3 78.4.2.3.
1.3.111.2.802.3.1.5.1.3.4.1.5Integer32read-onlycurrent
lldpV2Xdot3Conformance
OBJECT-IDENTITY
1.3.111.2.802.3.1.5.2
lldpV2Xdot3Compliances
OBJECT-IDENTITY
1.3.111.2.802.3.1.5.2.1
lldpV2Xdot3Groups
OBJECT-IDENTITY
1.3.111.2.802.3.1.5.2.2

Conformance

NameOIDStatus
lldpV2Xdot3TxRxCompliance
MODULE-COMPLIANCE
A compliance statement for SNMP entities that implement the LLDP IEEE 802.3 organizational extension MIB. This group is mandatory for all agents that implement the LLDP IEEE 802.3 organizational extension in TX and/or RX mode. This version defines compliance requirements for V2 of the LLDP MIB.
1.3.111.2.802.3.1.5.2.1.1current
lldpV2Xdot3TxCompliance
MODULE-COMPLIANCE
The compliance statement for SNMP entities that implement the LLDP IEEE 802.3 organizational extension MIB. This group is mandatory for agents that implement the LLDP IEEE 802.3 organizational extension in the TX mode. This version defines compliance requirements for V2 of the LLDP MIB.
1.3.111.2.802.3.1.5.2.1.2current
lldpV2Xdot3RxCompliance
MODULE-COMPLIANCE
The compliance statement for SNMP entities that implement the LLDP IEEE 802.3 organizational extension MIB. This group is mandatory for agents that implement the LLDP IEEE 802.3 organizational extension in the RX mode. This version defines compliance requirements for V2 of the LLDP MIB.
1.3.111.2.802.3.1.5.2.1.3current
lldpV2Xdot3ConfigGroup
OBJECT-GROUP
The collection of objects that are used to configure the LLDP IEEE 802.3 organizational extension implementation behavior.
1.3.111.2.802.3.1.5.2.2.1current
lldpV2Xdot3LocSysGroup
OBJECT-GROUP
The collection of objects that are used to represent LLDP IEEE 802.3 organizational extension Local Device Information.
1.3.111.2.802.3.1.5.2.2.2current
lldpV2Xdot3RemSysGroup
OBJECT-GROUP
The collection of objects that are used to represent LLDP IEEE 802.3 organizational extension Local Device Information.
1.3.111.2.802.3.1.5.2.2.3current