IEEE8021-PSFP-MIB

Registered at
1.3.111.2.802.1.1.31
Last updated
2023-09-26 00:00
Organization
IEEE 802.1 Working Group
Revisions
2023-09-26 00:00, 2022-01-13 00:00, 2020-11-06 00:00, 2018-07-01 00:00, 2017-09-08 00:00
Namespace
standard
Source file
IEEE8021-PSFP-MIB
Digest
sha256:ce8d1d98fddfcc34a1325f70efd1af83c67758d80edb5652ea82f7fff4afde17

Description

The Bridge MIB module for managing devices that support the Per-Stream Filtering and Policing enhancements for IEEE 802.1Q Bridges. Unless otherwise indicated, the references in this MIB module are to IEEE Std 802.1Q-2022. Copyright (C) IEEE (2023). This version of this MIB module is part of IEEE Std 802.1Q; see that standard for full legal notices.

Contact

WG-URL: http://www.ieee802.org/1/ WG-EMail: stds-802-1-l@ieee.org Contact: IEEE 802.1 Working Group Chair Postal: C/O IEEE 802.1 Working Group IEEE Standards Association 445 Hoes Lane Piscataway, NJ 08854 USA E-mail: stds-802-1-chairs@ieee.org

Imports

FromSymbols
IEEE8021-BRIDGE-MIBieee8021BridgeBaseComponentId
IEEE8021-ST-MIBIEEE8021STPTPtimeValue
IEEE8021-TC-MIBieee802dot1mibs
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
SNMPv2-SMICounter64, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, iso
SNMPv2-TCDisplayString, RowStatus, TEXTUAL-CONVENTION, TruthValue

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IANAifType-MIB
IEEE8021-BRIDGE-MIB
IEEE8021-PSFP-MIB
IEEE8021-ST-MIB
IEEE8021-TC-MIB
IF-MIB
SNMP-FRAMEWORK-MIB
SNMPv2-CONF
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
ieee8021PSFPNotifications
OBJECT-IDENTITY
1.3.111.2.802.1.1.31.0
ieee8021PSFPObjects
OBJECT-IDENTITY
1.3.111.2.802.1.1.31.1
ieee8021PSFPStreamFilterParameters
OBJECT-IDENTITY
1.3.111.2.802.1.1.31.1.1
ieee8021PSFPStreamFilterTable
OBJECT-TYPE
A table that contains the per-filter instance manageable parameters for stream filters. A row in the table exists for each stream filter instance. associated with a Bridge component. All writable objects in this table must be persistent over power up restart/reboot.
1.3.111.2.802.1.1.31.1.1.1not-accessiblecurrent
ieee8021PSFPStreamFilterEntry
OBJECT-TYPE
A list of objects that contains the manageable parameters for stream filters for a Bridge component.
1.3.111.2.802.1.1.31.1.1.1.1not-accessiblecurrent
ieee8021PSFPStreamFilterInstance
OBJECT-TYPE
The StreamFilterInstance parameter is an index into the StreamFilterTable. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.1.1.1.1Unsigned32not-accessiblecurrent
ieee8021PSFPStreamHandleSpec
OBJECT-TYPE
The StreamHandleSpec parameter contains a stream identifier specification value. A value of -1 denotes the wild card value; all positive values denote stream identifier values. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.1.1.1.2Integer32 (-1..2147483647)read-createcurrent
ieee8021PSFPPrioritySpec
OBJECT-TYPE
The PrioritySpec parameter contains a priority specification value. A value of -1 denotes the wild card value; zero or positive values denote priority values. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.1.1.1.3Integer32 (-1..2147483647)read-createcurrent
ieee8021PSFPStreamGateInstanceID
OBJECT-TYPE
The StreamGateInstance parameter contains the index of an entry in the Stream Gate Table. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.1.1.1.4Unsigned32read-createcurrent
ieee8021PSFPFilterSpecificationList
OBJECT-TYPE
The FilterSpecificationList parameter contains a list of filter specifications associated with this stream filter. The octet string value represents the contents of the list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a filter specification type: 0: Maximum SDU Size. 1: Flow meter instance identifier. 2-255: Reserved for future filter specification types The second and third octets of the TLV are the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the filter specification has no parameters). The fourth through (4 + length -1)th octets encode the parameters of the filter specification, as defined for each filter specification type. - Maximum SDU Size: A single SDU size parameter is encoded in four octets, and is interpreted as an unsigned integer value. - Flow meter instance identifier: A single flow meter instance identifier is encoded in four octets, and is interpreted as an unsigned integer value. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.1.1.1.5OCTET STRINGread-createcurrent
ieee8021PSFPMatchingFramesCount
OBJECT-TYPE
The MatchingFramesCount counter counts received frames that match this stream filter.
1.3.111.2.802.1.1.31.1.1.1.1.6Counter64read-onlycurrent
ieee8021PSFPPassingFramesCount
OBJECT-TYPE
The PassingFramesCount counter counts received frames that pass the gate associated with this stream filter.
1.3.111.2.802.1.1.31.1.1.1.1.7Counter64read-onlycurrent
ieee8021PSFPNotPassingFramesCount
OBJECT-TYPE
The NotPassingFramesCount counter counts received frames that do not pass the gate associated with this stream filter.
1.3.111.2.802.1.1.31.1.1.1.1.8Counter64read-onlycurrent
ieee8021PSFPPassingSDUCount
OBJECT-TYPE
The PassingSDUCount counter counts received frames that pass the maximum SDU size filter specification associated with this stream filter.
1.3.111.2.802.1.1.31.1.1.1.1.9Counter64read-onlycurrent
ieee8021PSFPNotPassingSDUCount
OBJECT-TYPE
The NotPassingSDUCount counter counts received frames that do not pass the maximum SDU size filter specification associated with this stream filter.
1.3.111.2.802.1.1.31.1.1.1.1.10Counter64read-onlycurrent
ieee8021PSFPREDFramesCount
OBJECT-TYPE
The REDFramesCount counter counts received frames that were discarded as a result of the operation of the flow meter.
1.3.111.2.802.1.1.31.1.1.1.1.11Counter64read-onlycurrent
ieee8021PSFPStreamBlockedDueToOversizeFrameEnable
OBJECT-TYPE
The ieee8021PSFPStreamBlockedDueToOversizeFrameEnable object contains a Boolean value that indicates whether the StreamBlockedDueToOversizeFrame function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.1.1.1.12TruthValueread-createcurrent
ieee8021PSFPStreamBlockedDueToOversizeFrame
OBJECT-TYPE
The ieee8021PSFPStreamBlockedDueToOversizeFrame object contains a Boolean value that indicates whether, if the StreamBlockedDueToOversizeFrame function is enabled, all frames are to be discarded (TRUE) or not (FALSE). The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.1.1.1.13TruthValueread-createcurrent
ieee8021PSFPStreamFilterEntryRowStatus
OBJECT-TYPE
The status of the row. The writable columns in a row cannot be changed if the row is active. All columns MUST have a valid value before a row can be activated.
1.3.111.2.802.1.1.31.1.1.1.1.14RowStatusread-createcurrent
ieee8021PSFPStreamGateParameters
OBJECT-IDENTITY
1.3.111.2.802.1.1.31.1.2
ieee8021PSFPStreamGateTable
OBJECT-TYPE
A table that contains the per-gate instance manageable parameters for stream gate scheduling. For a given Bridge component, a row in the table exists for each stream gate instance. All writable objects in this table must be persistent over power up restart/reboot.
1.3.111.2.802.1.1.31.1.2.1not-accessiblecurrent
ieee8021PSFPStreamGateEntry
OBJECT-TYPE
A list of objects that contains the manageable parameters for stream gate scheduling for a Bridge component.
1.3.111.2.802.1.1.31.1.2.1.1not-accessiblecurrent
ieee8021PSFPStreamGateInstance
OBJECT-TYPE
The StreamGateInstance parameter is an index into the StreamGateTable. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.2.1.1.1Unsigned32not-accessiblecurrent
ieee8021PSFPGateEnabled
OBJECT-TYPE
The GateEnabled parameter determines whether the stream gate is active (true) or inactive (false). The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.2.1.1.2TruthValueread-createcurrent
ieee8021PSFPAdminGateStates
OBJECT-TYPE
The administrative value of the GateStates parameter for the stream gate. The open value indicates that the gate is open, the closed value indicates that the gate is closed. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.2.1.1.3INTEGER {open(1), closed(2)}read-createcurrent
ieee8021PSFPOperGateStates
OBJECT-TYPE
The operational value of the GateStates parameter for the stream gate. The open value indicates that the gate is open, the closed value indicates that the gate is closed.
1.3.111.2.802.1.1.31.1.2.1.1.4INTEGER {open(1), closed(2)}read-onlycurrent
ieee8021PSFPAdminControlListLength
OBJECT-TYPE
The administrative value of the ListMax parameter for the gate. The integer value indicates the number of entries (TLVs) in the AdminControlList. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.2.1.1.5Unsigned32read-createcurrent
ieee8021PSFPOperControlListLength
OBJECT-TYPE
The operational value of the ListMax parameter for the gate. The integer value indicates the number of entries (TLVs) in the OperControlList.
1.3.111.2.802.1.1.31.1.2.1.1.6Unsigned32read-onlycurrent
ieee8021PSFPAdminControlList
OBJECT-TYPE
The administrative value of the ControlList parameter for the gate. The octet string value represents the contents of the control list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a gate operation name: 0: SetGateAndIPV 1-255: Reserved for future gate operations The second octet of the TLV is the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the gate operation has no parameters). The third through (3 + length -1)th octets encode the parameters of the gate operation, in the order that they appear in the definition of the operation in Table 8-4. The first parameter is a StreamGateState value; the second parameter is an IPV value; the third parameter is a TimeInterval value; and the fourth parameter is an IntervalOctetMax value. IntervalOctetMax is optional. - StreamGateState: A GateState parameter is encoded in a single octet, and is interpreted as an integer value. The value 1 indicates open; the value 2 indicates closed. - IPV: An IPV is encoded in four octets as a 32-bit signed integer. A negative denotes the null value; zero or positive values denote internal priority values. - TimeInterval: A TimeInterval is encoded in 4 octets as a 32-bit unsigned integer, representing a number of nanoseconds. The first octet encodes the most significant 8 bits of the integer, and the fourth octet encodes the least significant 8 bits. - IntervalOctetMax: An integer representing the maximum number of MSDU octets that are permitted to pass the gate during the specified TimeInterval. If this parameter is omitted, there is no maximum. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.2.1.1.7OCTET STRINGread-createcurrent
ieee8021PSFPOperControlList
OBJECT-TYPE
The operational value of the ControlList parameter for the gate. The octet string value represents the contents of the control list as an ordered list of entries, each encoded as a TLV, as follows. The first octet of each TLV is interpreted as an unsigned integer representing a gate operation name: 0: SetGateAndIPV 1-255: Reserved for future gate operations The second octet of the TLV is the length field, interpreted as an unsigned integer, indicating the number of octets of the value that follows the length. A length of zero indicates that there is no value (i.e., the gate operation has no parameters). The third through (3 + length -1)th octets encode the parameters of the gate operation, in the order that they appear in the definition of the operation in Table 8-4. The first parameter is a StreamGateState value; the second parameter is an IPV value; the third parameter is a TimeInterval value; and the fourth parameter is an IntervalOctetMax value. IntervalOctetMax is optional. - StreamGateState: A GateState parameter is encoded in a single octet, and is interpreted as an integer value. The value 1 indicates open; the value 2 indicates closed. - IPV: An IPV is encoded in four octets as a 32-bit signed integer. A negative value denotes the null value; zero and positive values denote internal priority values. - TimeInterval: A TimeInterval is encoded in 4 octets as a 32-bit unsigned integer, representing a number of nanoseconds. The first octet encodes the most significant 8 bits of the integer, and the fourth octet encodes the least significant 8 bits. - IntervalOctetMax: An integer representing the maximum number of MSDU octets that are permitted to pass the gate during the specified TimeInterval. If this parameter is omitted, there is no maximum.
1.3.111.2.802.1.1.31.1.2.1.1.8OCTET STRINGread-onlycurrent
ieee8021PSFPAdminCycleTimeNumerator
OBJECT-TYPE
The administrative value of the numerator of the CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational number of seconds. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.2.1.1.9Unsigned32read-createcurrent
ieee8021PSFPAdminCycleTimeDenominator
OBJECT-TYPE
The administrative value of the denominator of the CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational number of seconds. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.2.1.1.10Unsigned32read-createcurrent
ieee8021PSFPOperCycleTimeNumerator
OBJECT-TYPE
The operational value of the numerator of the CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational number of seconds.
1.3.111.2.802.1.1.31.1.2.1.1.11Unsigned32read-onlycurrent
ieee8021PSFPOperCycleTimeDenominator
OBJECT-TYPE
The operational value of the denominator of the CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational number of seconds.
1.3.111.2.802.1.1.31.1.2.1.1.12Unsigned32read-onlycurrent
ieee8021PSFPAdminCycleTimeExtension
OBJECT-TYPE
The administrative value of the CycleTimeExtension parameter for the gate. The value is an unsigned integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.2.1.1.13Unsigned32read-createcurrent
ieee8021PSFPOperCycleTimeExtension
OBJECT-TYPE
The operational value of the CycleTimeExtension parameter for the gate. The value is an unsigned integer number of nanoseconds.
1.3.111.2.802.1.1.31.1.2.1.1.14Unsigned32read-onlycurrent
ieee8021PSFPAdminBaseTime
OBJECT-TYPE
The administrative value of the BaseTime parameter for the gate. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.2.1.1.15IEEE8021STPTPtimeValueread-createcurrent
ieee8021PSFPOperBaseTime
OBJECT-TYPE
The operational value of the BaseTime parameter for the gate. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds.
1.3.111.2.802.1.1.31.1.2.1.1.16IEEE8021STPTPtimeValueread-onlycurrent
ieee8021PSFPConfigChange
OBJECT-TYPE
The ConfigChange parameter signals the start of a configuration change for the gate when it is set to TRUE. This should only be done when the various administrative parameters are all set to appropriate values.
1.3.111.2.802.1.1.31.1.2.1.1.17TruthValueread-createcurrent
ieee8021PSFPConfigChangeTime
OBJECT-TYPE
The PTPtime at which the next config change is scheduled to occur. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.2.1.1.18IEEE8021STPTPtimeValueread-onlycurrent
ieee8021PSFPTickGranularity
OBJECT-TYPE
The granularity of the cycle time clock, represented as an unsigned number of tenths of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.2.1.1.19Unsigned32read-onlycurrent
ieee8021PSFPCurrentTime
OBJECT-TYPE
The current time, in PTPtime, as maintained by the local system. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds.
1.3.111.2.802.1.1.31.1.2.1.1.20IEEE8021STPTPtimeValueread-onlycurrent
ieee8021PSFPConfigPending
OBJECT-TYPE
The value of the ConfigPending state machine variable. The value is TRUE if a configuration change is in progress but has not yet completed.
1.3.111.2.802.1.1.31.1.2.1.1.21TruthValueread-onlycurrent
ieee8021PSFPConfigChangeError
OBJECT-TYPE
A counter of the number of times that a re-configuration of the traffic schedule has been requested with the old schedule still running and the requested base time was in the past.
1.3.111.2.802.1.1.31.1.2.1.1.23Counter64read-onlycurrent
ieee8021PSFPAdminIPV
OBJECT-TYPE
The administrative value of the IPV parameter for the gate. A value of -1 denotes the null value.
1.3.111.2.802.1.1.31.1.2.1.1.24Integer32 (-1..2147483647)read-createcurrent
ieee8021PSFPOperIPV
OBJECT-TYPE
The operational value of the IPV parameter for the gate. A value of -1 denotes the null value.
1.3.111.2.802.1.1.31.1.2.1.1.25Integer32 (-1..2147483647)read-createcurrent
ieee8021PSFPGateClosedDueToInvalidRxEnable
OBJECT-TYPE
The PSFPGateClosedDueToInvalidRxEnable object contains a Boolean value that indicates whether the GateClosedDueToInvalidRx function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.2.1.1.26TruthValueread-createcurrent
ieee8021PSFPGateClosedDueToInvalidRx
OBJECT-TYPE
The PSFPGateClosedDueToInvalidRx object contains a Boolean value that indicates whether, if the GateClosedDueToInvalidRx function is enabled, all frames are to be discarded (TRUE) or not (FALSE). The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.2.1.1.27TruthValueread-createcurrent
ieee8021PSFPGateClosedDueToOctetsExceededEnable
OBJECT-TYPE
The PSFPGateClosedDueToOctetsExceededEnable object contains a Boolean value that indicates whether the GateClosedDueToOctetsExceeded function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.2.1.1.28TruthValueread-createcurrent
ieee8021PSFPGateClosedDueToOctetsExceeded
OBJECT-TYPE
The PSFPGateClosedDueToOctetsExceeded parameter contains a Boolean value that indicates whether, if the GateClosedDueToOctetsExceeded function is enabled, all frames are to be discarded (TRUE) or not (FALSE). The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.2.1.1.29TruthValueread-createcurrent
ieee8021PSFPStreamGateEntryRowStatus
OBJECT-TYPE
The status of the row. The writable columns in a row cannot be changed if the row is active. All columns MUST have a valid value before a row can be activated.
1.3.111.2.802.1.1.31.1.2.1.1.30RowStatusread-createcurrent
ieee8021PSFPFlowMeterParameters
OBJECT-IDENTITY
1.3.111.2.802.1.1.31.1.3
ieee8021PSFPFlowMeterTable
OBJECT-TYPE
A table that contains the per-meter instance manageable parameters for flow meters. For a given Bridge component, a row in the table exists for each flow meter instance. All writable objects in this table must be persistent over power up restart/reboot.
1.3.111.2.802.1.1.31.1.3.1not-accessiblecurrent
ieee8021PSFPFlowMeterEntry
OBJECT-TYPE
A list of objects that contains the manageable parameters for flow meters for a Bridge component.
1.3.111.2.802.1.1.31.1.3.1.1not-accessiblecurrent
ieee8021PSFPFlowMeterInstance
OBJECT-TYPE
The FlowMeterInstance parameter is an index into the FlowMeterTable. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.3.1.1.1Unsigned32not-accessiblecurrent
ieee8021PSFPFlowMeterCIR
OBJECT-TYPE
The FlowMeterCIR parameter contains an integer value that represents the CIR value for the flow meter, in bit/second. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.3.1.1.2Unsigned32read-createcurrent
ieee8021PSFPFlowMeterCBS
OBJECT-TYPE
The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.3.1.1.3Unsigned32read-createcurrent
ieee8021PSFPFlowMeterEIR
OBJECT-TYPE
The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/second. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.3.1.1.4Unsigned32read-createcurrent
ieee8021PSFPFlowMeterEBS
OBJECT-TYPE
The FlowMeterEBS parameter contains an integer value that represents the EBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.3.1.1.5Unsigned32read-createcurrent
ieee8021PSFPFlowMeterCF
OBJECT-TYPE
The FlowMeterCF parameter contains an integer value that represents the CF value for the flow meter, as an integer value 0 or 1. The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.3.1.1.6Integer32 (0..1)read-createcurrent
ieee8021PSFPFlowMeterCM
OBJECT-TYPE
The FlowMeterCM parameter contains an integer value that represents the CM value for the flow meter, as an enumerated value indicating colorBlind(1) or colorAware(2). The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.3.1.1.7INTEGER {colorBlind(1), colorAware(2)}read-createcurrent
ieee8021PSFPFlowMeterDropOnYellow
OBJECT-TYPE
The FlowMeterDropOnYellow parameter contains a Boolean value that indicates whether yellow frames are dropped (TRUE) or have drop_eligible set to TRUE (FALSE). The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.3.1.1.8TruthValueread-createcurrent
ieee8021PSFPFlowMeterMarkAllFramesRedEnable
OBJECT-TYPE
The FlowMeterMarkAllFramesRedEnable parameter contains a Boolean value that indicates whether the MarkAllFramesRed function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.3.1.1.9TruthValueread-createcurrent
ieee8021PSFPFlowMeterMarkAllFramesRed
OBJECT-TYPE
The FlowMeterMarkAllFramesRed parameter contains a Boolean value that indicates whether, if the MarkAllFramesRed function is enabled, all frames are to be discarded (TRUE) or not (FALSE). The value of this object MUST be retained across reinitializations of the management system.
1.3.111.2.802.1.1.31.1.3.1.1.10TruthValueread-createcurrent
ieee8021PSFPFlowMeterEntryRowStatus
OBJECT-TYPE
The status of the row. The writable columns in a row cannot be changed if the row is active. All columns MUST have a valid value before a row can be activated.
1.3.111.2.802.1.1.31.1.3.1.1.11RowStatusread-createcurrent
ieee8021PSFPStreamParameters
OBJECT-IDENTITY
1.3.111.2.802.1.1.31.1.4
ieee8021PSFPStreamParameterTable
OBJECT-TYPE
A table that contains per-Bridge component manageable parameters for PSFP. A row in the table exists for each Bridge component. All writable objects in this table must be persistent over power up restart/reboot.
1.3.111.2.802.1.1.31.1.4.1not-accessiblecurrent
ieee8021PSFPStreamParameterEntry
OBJECT-TYPE
A list of objects that contains the manageable parameters for flow meters for a Bridge component.
1.3.111.2.802.1.1.31.1.4.1.1not-accessiblecurrent
ieee8021PSFPMaxStreamFilterInstances
OBJECT-TYPE
The MaxStreamFilterInstances parameter defines the maximum number of stream filter instances that are supported by this Bridge component.
1.3.111.2.802.1.1.31.1.4.1.1.1Unsigned32read-onlycurrent
ieee8021PSFPMaxStreamGateInstances
OBJECT-TYPE
The MaxStreamGateInstances parameter defines the maximum number of stream gate instances that are supported by this Bridge component.
1.3.111.2.802.1.1.31.1.4.1.1.2Unsigned32read-onlycurrent
ieee8021PSFPMaxFlowMeterInstances
OBJECT-TYPE
The MaxFlowMeterInstances parameter defines the maximum number of flow meter instances that are supported by this Bridge component.
1.3.111.2.802.1.1.31.1.4.1.1.3Unsigned32read-onlycurrent
ieee8021PSFPSupportedListMax
OBJECT-TYPE
The SupportedListMax parameter defines the The maximum value supported by this Bridge component of the AdminControlListLength and OperControlListLength parameters.
1.3.111.2.802.1.1.31.1.4.1.1.4Unsigned32read-onlycurrent
ieee8021PSFPSupportedCycleMaxNumerator
OBJECT-TYPE
The numerator of the SupportedCycleMax parameter for the Bridge component. The numerator and denominator together represent the maximum value supported of the AdminCycleTime and OperCycleTime parameters
1.3.111.2.802.1.1.31.1.4.1.1.5Unsigned32read-onlycurrent
ieee8021PSFPSupportedCycleMaxDenominator
OBJECT-TYPE
The denominator of the SupportedCycleMax parameter for the Bridge component. The numerator and denominator together represent the maximum value supported of the AdminCycleTime and OperCycleTime parameters
1.3.111.2.802.1.1.31.1.4.1.1.6Unsigned32read-onlycurrent
ieee8021PSFPSupportedIntervalMax
OBJECT-TYPE
The maximum value supported by this Bridge component of the TimeIntervalValue parameter.
1.3.111.2.802.1.1.31.1.4.1.1.7Unsigned32read-onlycurrent
ieee8021PSFPConformance
OBJECT-IDENTITY
1.3.111.2.802.1.1.31.2
ieee8021PSFPCompliances
OBJECT-IDENTITY
1.3.111.2.802.1.1.31.2.1
ieee8021PSFPGroups
OBJECT-IDENTITY
1.3.111.2.802.1.1.31.2.2

Conformance

NameOIDStatus
ieee8021PSFPCompliance
MODULE-COMPLIANCE
The compliance statement for devices supporting PSFP. Support of the objects defined in this MIB module also requires support of the IEEE8021-BRIDGE-MIB; the provisions of 17.3.2 apply to implementations claiming support of this MIB.
1.3.111.2.802.1.1.31.2.1.1current
ieee8021PSFPObjectsGroup
OBJECT-GROUP
Objects that allow management of PSFP.
1.3.111.2.802.1.1.31.2.2.1current