IEEE8021-MSTP-MIB
- Registered at
- 1.3.111.2.802.1.1.6
- Last updated
- 2022-11-08 00:00
- Organization
- IEEE 802.1 Working Group
- Revisions
- 2022-11-08 00:00, 2018-07-01 00:00, 2014-12-15 00:00, 2012-08-10 00:00, 2011-12-12 00:00, 2011-03-23 00:00, 2008-10-15 00:00
- Namespace
- standard
- Source file
IEEE8021-MSTP-MIB- Digest
sha256:f50075c55e289af85d7b7cb61dfc34f67e125dcb94080d9a86b020a4feb4c5b2
Description
The Bridge MIB modules for managing devices that support IEEE Std 802.1Q multiple spanning tree groups. Unless otherwise indicated, the references in this MIB module are to IEEE Std 802.1Q-2022. Copyright (C) IEEE (2022). This version of this MIB module is part of IEEE Std 802.1Q; see that standard for full legal notices.
Contact
WG-URL: http://www.ieee802.org/1/ WG-EMail: stds-802-1-l@ieee.org Contact: IEEE 802.1 Working Group Chair Postal: C/O IEEE 802.1 Working Group IEEE Standards Association 445 Hoes Lane Piscataway, NJ 08854 USA E-mail: stds-802-1-chairs@ieee.org
Imports
| From | Symbols |
|---|---|
| BRIDGE-MIB | BridgeId |
| IEEE8021-TC-MIB | IEEE8021BridgePortNumber, IEEE8021MstIdentifier, IEEE8021PbbComponentIdentifier, IEEE8021VlanIndex, ieee802dot1mibs |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter64, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, RowStatus, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
BRIDGE-MIB IANAifType-MIB IEEE8021-MSTP-MIB IEEE8021-TC-MIB IF-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ieee8021MstpNotifications OBJECT-IDENTITY | 1.3.111.2.802.1.1.6.0 | |||
| ieee8021MstpObjects OBJECT-IDENTITY | 1.3.111.2.802.1.1.6.1 | |||
| ieee8021MstpCistTable OBJECT-TYPE The Common and Internal Spanning Tree (CIST) Table. Each row in the table represents information regarding a Bridge's Bridge Protocol Entity for the CIST. Note that entries will exist in this table only for Bridge components for which the corresponding instance of ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB) has a value of mstp(3). This table contains objects corresponding to the following items from 12.8.1.1 and 12.8.1.3. Some of those items are provided in the IEEE8021-SPANNING-TREE-MIB as noted below. From 12.8.1.1: Items a), c), o), p), and q) are defined in this table The remaining items are covered in the IEEE8021-SPANNING-TREE-MIB: b) ieee8021SpanningTreeTimeSinceTopologyChange c) ieee8021SpanningTreeTopChanges e) ieee8021SpanningTreeDesignatedRoot f) ieee8021SpanningTreeRootCost g) ieee8021SpanningTreeRootPort h) ieee8021SpanningTreeMaxAge i) ieee8021SpanningTreeForwardDelay j) ieee8021SpanningTreeBridgeMaxAge k) ieee8021SpanningTreeBridgeHelloTime l) ieee8021SpanningTreeBridgeForwardDelay m) ieee8021SpanningTreeHoldTime n) ieee8021SpanningTreeVersion From 12.8.1.3: Item g) is defined in this table The remaining items are covered in the IEEE8021-SPANNING-TREE-MIB: a) ieee8021SpanningTreeBridgeMaxAge b) ieee8021SpanningTreeBridgeHelloTime c) ieee8021SpanningTreeBridgeForwardDelay d) ieee8021SpanningTreePriority e) ieee8021SpanningTreeVersion f) ieee8021RstpStpExtTxHoldCount | 1.3.111.2.802.1.1.6.1.1 | not-accessible | current | |
| ieee8021MstpCistEntry OBJECT-TYPE A CIST Table entry. | 1.3.111.2.802.1.1.6.1.1.1 | not-accessible | current | |
| ieee8021MstpCistComponentId OBJECT-TYPE The component identifier is used to distinguish between the multiple virtual Bridge instances within a PBB. In simple situations where there is only a single component the default value is 1. | 1.3.111.2.802.1.1.6.1.1.1.1 | IEEE8021PbbComponentIdentifier | not-accessible | current |
| ieee8021MstpCistBridgeIdentifier OBJECT-TYPE The Bridge Identifier for the CIST. | 1.3.111.2.802.1.1.6.1.1.1.2 | BridgeId | read-only | current |
| ieee8021MstpCistTopologyChange OBJECT-TYPE In an STP Bridge, the value of the Topology Change parameter (14.8.1.1.3, item d of IEEE Std 802.1D, 2004 Edition), or in an RSTP or MSTP Bridge, asserted if the tcWhile timer for any Port for the CIST is non-zero. | 1.3.111.2.802.1.1.6.1.1.1.3 | TruthValue | read-only | current |
| ieee8021MstpCistRegionalRootIdentifier OBJECT-TYPE In an MSTP Bridge, the CIST Regional Root Identifier parameter, i.e., the Bridge Identifier of the current CIST Regional Root. | 1.3.111.2.802.1.1.6.1.1.1.4 | BridgeId | read-only | current |
| ieee8021MstpCistPathCost OBJECT-TYPE In an MSTP Bridge, the CIST Path Cost parameter, i.e., the CIST path cost from the transmitting Bridge to the CIST Regional Root. The sum (about 20 possible out of the given range) of multiple port path costs. Also, if the 'transmitting Bridge' is the 'CIST Regional Root', then this value could be zero. | 1.3.111.2.802.1.1.6.1.1.1.5 | Unsigned32 (0..2147483647) | read-only | current |
| ieee8021MstpCistMaxHops OBJECT-TYPE In an MSTP Bridge, the MaxHops parameter. The value of this object MUST be retained across reinitializations of the management system. | 1.3.111.2.802.1.1.6.1.1.1.6 | Integer32 (6..40) | read-write | current |
| ieee8021MstpTable OBJECT-TYPE In an MSTP Bridge, the MSTP Table. Each row in the Table represents information regarding a Bridge's Bridge Protocol Entity for the specified Spanning Tree instance. Entries in this table MUST be retained across reinitializations of the management system. Note that entries can be created in this table only for Bridge components for which the corresponding instance of ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB) has a value of mstp(3). | 1.3.111.2.802.1.1.6.1.2 | not-accessible | current | |
| ieee8021MstpEntry OBJECT-TYPE A MSTP Table entry. | 1.3.111.2.802.1.1.6.1.2.1 | not-accessible | current | |
| ieee8021MstpComponentId OBJECT-TYPE The component identifier is used to distinguish between the multiple virtual Bridge instances within a PBB. In simple situations where there is only a single component the default value is 1. | 1.3.111.2.802.1.1.6.1.2.1.1 | IEEE8021PbbComponentIdentifier | not-accessible | current |
| ieee8021MstpId OBJECT-TYPE In an MSTP Bridge, this parameter is the MSTID, i.e., the identifier of a Spanning Tree (or MST) Instance. | 1.3.111.2.802.1.1.6.1.2.1.2 | IEEE8021MstIdentifier | not-accessible | current |
| ieee8021MstpBridgeId OBJECT-TYPE In an MSTP Bridge, the Bridge Identifier for the MSTI. | 1.3.111.2.802.1.1.6.1.2.1.3 | BridgeId | read-only | current |
| ieee8021MstpTimeSinceTopologyChange OBJECT-TYPE In an MSTP Bridge, count in seconds of the time elapsed since tcWhile was last non-zero for any Port for the MSTI. | 1.3.111.2.802.1.1.6.1.2.1.4 | TimeTicks | read-only | current |
| ieee8021MstpTopologyChanges OBJECT-TYPE In an MSTP Bridge, count of the times tcWhile has been non-zero for any Port for the MSTI since the Bridge was powered on or initialized. | 1.3.111.2.802.1.1.6.1.2.1.5 | Counter64 | read-only | current |
| ieee8021MstpTopologyChange OBJECT-TYPE In an MSTP Bridge, the Topology Change parameter value: true(1) if tcWhile is non-zero for any Port for the MSTI. | 1.3.111.2.802.1.1.6.1.2.1.6 | TruthValue | read-only | current |
| ieee8021MstpDesignatedRoot OBJECT-TYPE In an MSTP Bridge, the Designated Root parameter value, i.e., the Bridge Identifier of the Root Bridge for the MSTI. | 1.3.111.2.802.1.1.6.1.2.1.7 | BridgeId | read-only | current |
| ieee8021MstpRootPathCost OBJECT-TYPE In an MSTP Bridge, the Root Path Cost parameter value, i.e., the path cost from the transmitting Bridge to the Root Bridge for the MSTI. | 1.3.111.2.802.1.1.6.1.2.1.8 | Integer32 | read-only | current |
| ieee8021MstpRootPort OBJECT-TYPE In an MSTP Bridge, the Root Port parameter value, i.e., the Root Port for the MSTI. | 1.3.111.2.802.1.1.6.1.2.1.9 | IEEE8021BridgePortNumber | read-only | current |
| ieee8021MstpBridgePriority OBJECT-TYPE In an MSTP Bridge, the Bridge Priority parameter value for the MSTI, i.e., the most significant 4 bits of the Bridge Identifier for the MSTI. | 1.3.111.2.802.1.1.6.1.2.1.10 | Integer32 (0..61440) | read-create | current |
| ieee8021MstpVids0 OBJECT-TYPE This object contains the first 1024 bits of the 4096 bit vector indicating which VIDs are assigned to this MSTID. The high order bit of the first octet corresponds to the first bit of the vector, while the low order bit of the last octet corresponds to the last bit of this portion of the vector. A bit that is on (equal to 1) indicates that the corresponding VID is assigned to this MSTID. | 1.3.111.2.802.1.1.6.1.2.1.11 | OCTET STRING (SIZE(128)) | read-only | current |
| ieee8021MstpVids1 OBJECT-TYPE This object contains the second 1024 bits of the 4096 bit vector indicating which VIDs are assigned to this MSTID. The high order bit of the first octet corresponds to the first bit of this portion of the vector, while the low order bit of the last octet corresponds to the last bit of this portion of the vector. A bit that is on (equal to 1) indicates that the corresponding VID is assigned to this MSTID. | 1.3.111.2.802.1.1.6.1.2.1.12 | OCTET STRING (SIZE(128)) | read-only | current |
| ieee8021MstpVids2 OBJECT-TYPE This object contains the third 1024 bits of the 4096 bit vector indicating which VIDs are assigned to this MSTID. The high order bit of the first octet corresponds to the first bit of this portion of the vector, while the low order bit of the last octet corresponds to the last bit of this portion of the vector. A bit that is on (equal to 1) indicates that the corresponding VID is assigned to this MSTID. | 1.3.111.2.802.1.1.6.1.2.1.13 | OCTET STRING (SIZE(128)) | read-only | current |
| ieee8021MstpVids3 OBJECT-TYPE This object contains the fourth 1024 bits of the 4096 bit vector indicating which VIDs are assigned to this MSTID. The high order bit of the first octet corresponds to the first bit of this portion of the vector, while the low order bit of the last octet corresponds to the last bit of this portion of the vector. A bit that is on (equal to 1) indicates that the corresponding VID is assigned to this MSTID. | 1.3.111.2.802.1.1.6.1.2.1.14 | OCTET STRING (SIZE(128)) | read-only | current |
| ieee8021MstpRowStatus OBJECT-TYPE The status of the row. Read SNMPv2-TC (RFC2579) for an explanation of the possible values this object can take. The writable columns in a row cannot be changed if the row is active. All columns must have a valid value before a row can be activated. | 1.3.111.2.802.1.1.6.1.2.1.15 | RowStatus | read-create | current |
| ieee8021MstpCistPortTable OBJECT-TYPE The CIST Port Table. Each row in the Table represents information regarding a specific Port within the Bridge's Bridge Protocol Entity, for the CIST. The values of all writable objects in this table MUST be retained across reinitializations of the management system. Note that entries will exist in this table only for Bridge components for which the corresponding instance of ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB) has a value of mstp(3). This table contains objects corresponding to the following items from 12.8.2.1, 12.8.2.3, and 12.8.2.5. Some of those items are provided in the IEEE8021-SPANNING-TREE-MIB as noted below. From 12.8.2.1: Items a), d), e), and i) through w) are defined in this table The remaining items are covered in the IEEE8021-SPANNING-TREE-MIB: b) ieee8021SpanningTreePortState c) ieee8021SpanningTreePortPriority d) ieee8021SpanningTreePortPathCost f) ieee8021SpanningTreePortDesignatedCost g) ieee8021SpanningTreePortDesignatedBridge h) ieee8021SpanningTreePortDesignatedPort From 12.8.2.3: Items a), b), and d) through h) are defined in this table (item a is the index) The remaining items are covered in the IEEE8021-SPANNING-TREE-MIB: b) ieee8021SpanningTreePortPathCost, c) ieee8021SpanningTreePortPriority From 12.8.2.5: All items are defined in this table Also from 12.8.2.1: Items u), v), w), and x) are defined in this table Also from 12.8.2.3: Items i), j), k), and l) are defined in this table | 1.3.111.2.802.1.1.6.1.3 | not-accessible | current | |
| ieee8021MstpCistPortEntry OBJECT-TYPE A CIST Port Table entry. | 1.3.111.2.802.1.1.6.1.3.1 | not-accessible | current | |
| ieee8021MstpCistPortComponentId OBJECT-TYPE The component identifier is used to distinguish between the multiple virtual Bridge instances within a PBB. In simple situations where there is only a single component the default value is 1. | 1.3.111.2.802.1.1.6.1.3.1.1 | IEEE8021PbbComponentIdentifier | not-accessible | current |
| ieee8021MstpCistPortNum OBJECT-TYPE The Port's Port Number parameter value for the CIST, i.e., the number of the Bridge Port for the CIST. | 1.3.111.2.802.1.1.6.1.3.1.2 | IEEE8021BridgePortNumber | not-accessible | current |
| ieee8021MstpCistPortUptime OBJECT-TYPE The Port's Uptime parameter value for the CIST, i.e., the count in seconds of the time elapsed since the Port was last reset or initialized (BEGIN, Annex E). | 1.3.111.2.802.1.1.6.1.3.1.3 | TimeTicks | read-only | current |
| ieee8021MstpCistPortAdminPathCost OBJECT-TYPE The administratively assigned value for the contribution of this port to the path cost of paths toward the spanning tree root. Writing a value of '0' assigns the automatically calculated default Path Cost value to the port. If the default Path Cost is being used, this object returns '0' when read. This complements the object ieee8021MstpCistPortCistPathCost, which returns the operational value of the port path cost. The value of this object MUST be retained across reinitializations of the management system. | 1.3.111.2.802.1.1.6.1.3.1.4 | Integer32 (0..200000000) | read-write | current |
| ieee8021MstpCistPortDesignatedRoot OBJECT-TYPE The CIST Regional Root Identifier component of the Port's port priority vector, as defined in 13.10, for the CIST. | 1.3.111.2.802.1.1.6.1.3.1.5 | BridgeId | read-only | current |
| ieee8021MstpCistPortTopologyChangeAck OBJECT-TYPE The Port's Topology Change Acknowledge parameter value. True(1) if a Configuration Message with a topology change acknowledge flag set is to be transmitted. | 1.3.111.2.802.1.1.6.1.3.1.6 | TruthValue | read-only | current |
| ieee8021MstpCistPortHelloTime OBJECT-TYPE The Port's Hello Time timer parameter value, for the CIST. In centi-seconds | 1.3.111.2.802.1.1.6.1.3.1.7 | Integer32 (100..1000) | read-only | current |
| ieee8021MstpCistPortAdminEdgePort OBJECT-TYPE In a Bridge that supports the identification of edge ports, the Port's Admin Edge Port parameter value, for the CIST. | 1.3.111.2.802.1.1.6.1.3.1.8 | TruthValue | read-write | current |
| ieee8021MstpCistPortOperEdgePort OBJECT-TYPE In a Bridge that supports the identification of edge ports, the Port's operational Edge Port parameter value, for the CIST. True(1) if it is an operEdge Port. | 1.3.111.2.802.1.1.6.1.3.1.9 | TruthValue | read-only | current |
| ieee8021MstpCistPortMacEnabled OBJECT-TYPE In a Bridge that supports the MAC Enabled parameter, the current state of the MAC Enabled parameter. True(1) indicates that administratively the MAC is set as if it was connected to a point-to-point LAN. | 1.3.111.2.802.1.1.6.1.3.1.10 | TruthValue | read-write | current |
| ieee8021MstpCistPortMacOperational OBJECT-TYPE In a Bridge that supports the MAC Operational parameter, the current state of the MAC Operational parameter. True(1) indicates the MAC is operational. | 1.3.111.2.802.1.1.6.1.3.1.11 | TruthValue | read-only | current |
| ieee8021MstpCistPortRestrictedRole OBJECT-TYPE The current state of the restrictedRole parameter for the Port. True(1) causes the Port not to be selected as Root Port for the CIST or any MSTI. | 1.3.111.2.802.1.1.6.1.3.1.12 | TruthValue | read-write | current |
| ieee8021MstpCistPortRestrictedTcn OBJECT-TYPE The current state of the restrictedTcn parameter for the Port. True(1) causes the Port not to propagate topology changes to other Ports. | 1.3.111.2.802.1.1.6.1.3.1.13 | TruthValue | read-write | current |
| ieee8021MstpCistPortRole OBJECT-TYPE The current Port Role for the Port (i.e., Root, Alternate, Designated, or Backup), for the CIST. | 1.3.111.2.802.1.1.6.1.3.1.14 | INTEGER {root(1), alternate(2), designated(3), backup(4)} | read-only | current |
| ieee8021MstpCistPortDisputed OBJECT-TYPE The current value of the disputed variable for the CIST for the Port. A value of true(1) indicates that the disputed variable is set. A value of false(2) indicates that the agreed variable is cleared. | 1.3.111.2.802.1.1.6.1.3.1.15 | TruthValue | read-only | current |
| ieee8021MstpCistPortCistRegionalRootId OBJECT-TYPE In an MSTP Bridge, the CIST Regional Root Identifier, i.e., the Bridge Identifier of the current CIST Regional Root, for the CIST. | 1.3.111.2.802.1.1.6.1.3.1.16 | BridgeId | read-only | current |
| ieee8021MstpCistPortCistPathCost OBJECT-TYPE In an MSTP Bridge, the Port's Port Path Cost parameter value for the CIST. | 1.3.111.2.802.1.1.6.1.3.1.17 | Unsigned32 (0..2147483647) | read-only | current |
| ieee8021MstpCistPortProtocolMigration OBJECT-TYPE In an MSTP Bridge, the current value of the mcheck variable for the Port. A value of true(1) forces the state machine to perform functions as per 13.27.38. | 1.3.111.2.802.1.1.6.1.3.1.18 | TruthValue | read-write | current |
| ieee8021MstpCistPortEnableBPDURx OBJECT-TYPE In an MSTP Bridge, the enableBPDUrx parameter value. A value of false(2) indicates that BPDUs are ignored. | 1.3.111.2.802.1.1.6.1.3.1.19 | TruthValue | read-write | current |
| ieee8021MstpCistPortEnableBPDUTx OBJECT-TYPE In an MSTP Bridge, the enableBPDUtx parameter value. A value of false(2) indicates that BPDUs are not transmitted. | 1.3.111.2.802.1.1.6.1.3.1.20 | TruthValue | read-write | current |
| ieee8021MstpCistPortPseudoRootId OBJECT-TYPE In an MSTP Bridge, the pseudoRootId parameter value. | 1.3.111.2.802.1.1.6.1.3.1.21 | BridgeId | read-write | current |
| ieee8021MstpCistPortIsL2Gp OBJECT-TYPE In an MSTP Bridge, the isL2gp parameter value. A value of true(1) indicates this is an L2GP port. | 1.3.111.2.802.1.1.6.1.3.1.22 | TruthValue | read-write | current |
| ieee8021MstpPortTable OBJECT-TYPE The MSTP Port Table. Each row in the Table represents information regarding a specific Port within the Bridge's Bridge Protocol Entity, for a given MSTI. The values of all writable objects in this table MUST be retained across reinitializations of the management system. Note that entries will exist in this table only for Bridge components for which the corresponding instance of ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB) has a value of mstp(3). | 1.3.111.2.802.1.1.6.1.4 | not-accessible | current | |
| ieee8021MstpPortEntry OBJECT-TYPE A MSTP Port Table entry. | 1.3.111.2.802.1.1.6.1.4.1 | not-accessible | current | |
| ieee8021MstpPortComponentId OBJECT-TYPE The component identifier is used to distinguish between the multiple virtual Bridge instances within a PBB. In simple situations where there is only a single component the default value is 1. | 1.3.111.2.802.1.1.6.1.4.1.1 | IEEE8021PbbComponentIdentifier | not-accessible | current |
| ieee8021MstpPortMstId OBJECT-TYPE In an MSTP Bridge, this parameter is the MSTID, i.e., the identifier of a Spanning Tree (or MST) Instance. | 1.3.111.2.802.1.1.6.1.4.1.2 | IEEE8021MstIdentifier | not-accessible | current |
| ieee8021MstpPortNum OBJECT-TYPE In an MSTP Bridge, the Port's Port Number parameter value for the MSTI, i.e., the number of the Bridge Port for the MSTI. | 1.3.111.2.802.1.1.6.1.4.1.3 | IEEE8021BridgePortNumber | not-accessible | current |
| ieee8021MstpPortUptime OBJECT-TYPE In an MSTP Bridge, the Port's Uptime parameter value for the MSTI, i.e., the count in seconds of the time elapsed since the Port was last reset or initialized (BEGIN, Annex E). | 1.3.111.2.802.1.1.6.1.4.1.4 | TimeTicks | read-only | current |
| ieee8021MstpPortState OBJECT-TYPE In an MSTP Bridge, the current state of the Port (i.e., Disabled, Listening, Learning, Forwarding, or Blocking), for the MSTI. | 1.3.111.2.802.1.1.6.1.4.1.5 | INTEGER {disabled(1), listening(2), learning(3), forwarding(4), blocking(5)} | read-only | current |
| ieee8021MstpPortPriority OBJECT-TYPE In an MSTP Bridge, the Port's Port Priority parameter value for the MSTI, i.e., the priority field for the Port Identifier for the Port for the MSTI. | 1.3.111.2.802.1.1.6.1.4.1.6 | Integer32 (0..240) | read-write | current |
| ieee8021MstpPortPathCost OBJECT-TYPE In an MSTP Bridge, the Port's Port Path Cost parameter value for the MSTI. | 1.3.111.2.802.1.1.6.1.4.1.7 | Integer32 (1..200000000) | read-write | current |
| ieee8021MstpPortDesignatedRoot OBJECT-TYPE In an MSTP Bridge, the Regional Root Identifier component of the Port's MSTI port priority vector, as defined in 13.11, for the MSTI. | 1.3.111.2.802.1.1.6.1.4.1.8 | BridgeId | read-only | current |
| ieee8021MstpPortDesignatedCost OBJECT-TYPE In an MSTP Bridge, the Internal Root Path Cost component of the Port's MSTI port priority vector, as defined in 13.11, for the MSTI. | 1.3.111.2.802.1.1.6.1.4.1.9 | Integer32 | read-only | current |
| ieee8021MstpPortDesignatedBridge OBJECT-TYPE In an MSTP Bridge, the Designated Bridge Identifier component of the Port's MSTI port priority vector, as defined in 13.11, for the MSTI. | 1.3.111.2.802.1.1.6.1.4.1.10 | BridgeId | read-only | current |
| ieee8021MstpPortDesignatedPort OBJECT-TYPE In an MSTP Bridge, the Designated Port Identifier component of the Port's MSTI port priority vector, as defined in 13.11, for the MSTI. | 1.3.111.2.802.1.1.6.1.4.1.11 | IEEE8021BridgePortNumber | read-only | current |
| ieee8021MstpPortRole OBJECT-TYPE In an MSTP Bridge, the current Port Role for the Port (i.e., Root, Alternate, Designated, or Backup), for the MSTI. | 1.3.111.2.802.1.1.6.1.4.1.12 | INTEGER {root(1), alternate(2), designated(3), backup(4)} | read-only | current |
| ieee8021MstpPortDisputed OBJECT-TYPE In an MSTP Bridge, the current value of the disputed variable for the MSTI for the Port. | 1.3.111.2.802.1.1.6.1.4.1.13 | TruthValue | read-only | current |
| ieee8021MstpPortAdminPathCost OBJECT-TYPE In an MSTP Bridge, the administrative value of the Port's Port Path Cost parameter value for the MSTI. Writing a value of '0' assigns the automatically calculated default Path Cost value to the Port. If the default Path Cost is being used, this object returns '0' when read. This complements the object ieee8021MstpPortPathCost, which returns the operational value of the path cost. The value of this object MUST be retained across reinitializations of the management system. | 1.3.111.2.802.1.1.6.1.4.1.14 | Integer32 (1..200000000) | read-write | current |
| ieee8021MstpFidToMstiTable OBJECT-TYPE In an MSTP Bridge, the fixed-length FID to MSTID Allocation Table entry. Each entry in the Table corresponds to a FID, and the value of the entry specifies the MSTID of the spanning tree to which the set of VLANs supported by that FID are assigned. A value of zero in an entry specifies that the set of VLANs supported by that FID are assigned to the CST. The values of all writable objects in this table MUST be retained across reinitializations of the management system. Note that entries will exist in this table only for Bridge components for which the corresponding instance of ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB) has a value of mstp(3). | 1.3.111.2.802.1.1.6.1.5 | not-accessible | deprecated | |
| ieee8021MstpFidToMstiEntry OBJECT-TYPE In an MSTP Bridge, a FID to MSTID Allocation Table entry. | 1.3.111.2.802.1.1.6.1.5.1 | not-accessible | deprecated | |
| ieee8021MstpFidToMstiComponentId OBJECT-TYPE The component identifier is used to distinguish between the multiple virtual Bridge instances within a PBB. In simple situations where there is only a single component the default value is 1. | 1.3.111.2.802.1.1.6.1.5.1.1 | IEEE8021PbbComponentIdentifier | not-accessible | deprecated |
| ieee8021MstpFidToMstiFid OBJECT-TYPE In an MSTP Bridge, the FID of the entry in the FID to MSTID Allocation Table. | 1.3.111.2.802.1.1.6.1.5.1.2 | Unsigned32 (1..4094) | not-accessible | deprecated |
| ieee8021MstpFidToMstiMstId OBJECT-TYPE In an MSTP Bridge, the MSTID to which the FID (of the entry in the FID to MSTID Allocation Table) is to be allocated. | 1.3.111.2.802.1.1.6.1.5.1.3 | IEEE8021MstIdentifier | read-write | deprecated |
| ieee8021MstpVlanTable OBJECT-TYPE In an MSTP Bridge, the fixed-length (4094 elements), read-only, MST Configuration Table. Its elements are derived from other configuration information held by the Bridge; specifically, the current state of the VID to FID Allocation Table (8.8.8, 12.10.1),and the FID to MSTID Allocation Table (8.9.3, 12.12.2). Hence, changes made to either of these Tables can in turn affect the contents of the MST Configuration Table, and also affect the value of the digest element of the MST Configuration Identifier. The values of all writable objects in this table MUST be retained across reinitializations of the management system. Note that entries will exist in this table only for Bridge components for which the corresponding instance of ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB) has a value of mstp(3). | 1.3.111.2.802.1.1.6.1.6 | not-accessible | deprecated | |
| ieee8021MstpVlanEntry OBJECT-TYPE In an MSTP Bridge, a MST Configuration Table entry. | 1.3.111.2.802.1.1.6.1.6.1 | not-accessible | deprecated | |
| ieee8021MstpVlanComponentId OBJECT-TYPE The component identifier is used to distinguish between the multiple virtual Bridge instances within a PBB. In simple situations where there is only a single component the default value is 1. | 1.3.111.2.802.1.1.6.1.6.1.1 | IEEE8021PbbComponentIdentifier | not-accessible | deprecated |
| ieee8021MstpVlanId OBJECT-TYPE In an MSTP Bridge, the VID of the entry in the MST Configuration Table. | 1.3.111.2.802.1.1.6.1.6.1.2 | IEEE8021VlanIndex | not-accessible | deprecated |
| ieee8021MstpVlanMstId OBJECT-TYPE In an MSTP Bridge, the MSTID value corresponding to the VID of the entry in the MST Configuration Table. | 1.3.111.2.802.1.1.6.1.6.1.3 | IEEE8021MstIdentifier | read-only | deprecated |
| ieee8021MstpConfigIdTable OBJECT-TYPE A table containing the MST Configuration Identifier for each virtual Bridge. In simple situations where there is only a single component, there will only be a single entry in this table (i.e., only a single MST Configuration Identifier). The values of all writable objects in this table MUST be retained across reinitializations of the management system. Note that entries will exist in this table only for Bridge components for which the corresponding instance of ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB) has a value of mstp(3). | 1.3.111.2.802.1.1.6.1.7 | not-accessible | current | |
| ieee8021MstpConfigIdEntry OBJECT-TYPE An entry containing the MST Configuration Identifier of a Bridge. | 1.3.111.2.802.1.1.6.1.7.1 | not-accessible | current | |
| ieee8021MstpConfigIdComponentId OBJECT-TYPE The component identifier is used to distinguish between the multiple virtual Bridge instances within a PBB. In simple situations where there is only a single component the default value is 1. | 1.3.111.2.802.1.1.6.1.7.1.1 | IEEE8021PbbComponentIdentifier | not-accessible | current |
| ieee8021MstpConfigIdFormatSelector OBJECT-TYPE In an MSTP Bridge, the Configuration Identifier Format Selector in use by the Bridge, in the MST Configuration Identifier. This has a value of 0 to indicate the format specified in IEEE Std 802.1Q. | 1.3.111.2.802.1.1.6.1.7.1.2 | Integer32 (0) | read-write | current |
| ieee8021MstpConfigurationName OBJECT-TYPE In an MSTP Bridge, the Configuration Name in the MST Configuration Identifier. | 1.3.111.2.802.1.1.6.1.7.1.3 | SnmpAdminString (SIZE(32)) | read-write | current |
| ieee8021MstpRevisionLevel OBJECT-TYPE In an MSTP Bridge, the Revision Level in the MST Configuration Identifier. | 1.3.111.2.802.1.1.6.1.7.1.4 | Unsigned32 (0..65535) | read-write | current |
| ieee8021MstpConfigurationDigest OBJECT-TYPE In an MSTP Bridge, the Configuration Digest in the MST Configuration Identifier. | 1.3.111.2.802.1.1.6.1.7.1.5 | OCTET STRING (SIZE(16)) | read-only | current |
| ieee8021MstpCistPortExtensionTable OBJECT-TYPE The CIST Port Extensions Table. Each row in the Table represents information regarding a specific Port within the Bridge's Bridge Protocol Entity, for the CIST. | 1.3.111.2.802.1.1.6.1.8 | not-accessible | current | |
| ieee8021MstpCistPortExtensionEntry OBJECT-TYPE A list of additional objects containing information maintained by every port about the CIST state for that port. | 1.3.111.2.802.1.1.6.1.8.1 | not-accessible | current | |
| ieee8021MstpCistPortAutoEdgePort OBJECT-TYPE The administrative value of the Auto Edge Port parameter. A value of true(1) indicates if the Bridge detection state machine (BDM, 13.33) is to detect other Bridges attached to the LAN, and set ieee8021SpanningTreeRstpPortOperEdgePort automatically. The default value is true(1) This is optional and provided only by implementations that support the automatic identification of edge ports. The value of this object MUST be retained across reinitializations of the management system. | 1.3.111.2.802.1.1.6.1.8.1.1 | TruthValue | read-write | current |
| ieee8021MstpCistPortAutoIsolatePort OBJECT-TYPE The operational value of the Isolate Port parameter. A value of true(1) indicates a Designated Port will transition to discarding if both ieee8021SpanningTreeRstpPortAdminEdgePort and ieee8021SpanningTreeRstpPortAutoEdgePort are FALSE and the other Bridge presumed to be attached to the same point-to-point LAN does not transmit periodic BPDUs. This is optional and provided only by implementations that support the automatic identification of fragile Bridges. | 1.3.111.2.802.1.1.6.1.8.1.2 | TruthValue | read-only | current |
| ieee8021MstpFidToMstiV2Table OBJECT-TYPE In an MSTP Bridge, the fixed-length FID to MSTID Allocation Table entry. Each entry in the Table corresponds to a FID, and the value of the entry specifies the MSTID of the spanning tree to which the set of VLANs supported by that FID are assigned. A value of zero in an entry specifies that the set of VLANs supported by that FID are assigned to the CST. The values of all writable objects in this table MUST be retained across reinitializations of the management system. Note that entries will exist in this table only for Bridge components for which the corresponding instance of ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB) has a value of mstp(3). | 1.3.111.2.802.1.1.6.1.9 | not-accessible | current | |
| ieee8021MstpFidToMstiV2Entry OBJECT-TYPE In an MSTP Bridge, a FID to MSTID Allocation Table entry. | 1.3.111.2.802.1.1.6.1.9.1 | not-accessible | current | |
| ieee8021MstpFidToMstiV2ComponentId OBJECT-TYPE The component identifier is used to distinguish between the multiple virtual Bridge instances within a PBB. In simple situations where there is only a single component the default value is 1. | 1.3.111.2.802.1.1.6.1.9.1.1 | IEEE8021PbbComponentIdentifier | not-accessible | current |
| ieee8021MstpFidToMstiV2Fid OBJECT-TYPE In an MSTP Bridge, the FID of the entry in the FID to MSTID Allocation Table. | 1.3.111.2.802.1.1.6.1.9.1.2 | Unsigned32 (1..4095) | not-accessible | current |
| ieee8021MstpFidToMstiV2MstId OBJECT-TYPE In an MSTP Bridge, the MSTID to which the FID (of the entry in the FID to MSTID Allocation Table) is to be allocated. In an SPT Bridge, the value 4095 is used to indicate unused (non-filtering) FIDs. | 1.3.111.2.802.1.1.6.1.9.1.3 | Unsigned32 (0..4095) | read-write | current |
| ieee8021MstpVlanV2Table OBJECT-TYPE In an MSTP Bridge, the fixed-length (4094 elements), read-only, MST Configuration Table. Its elements are derived from other configuration information held by the Bridge; specifically, the current state of the VID to FID Allocation Table (8.8.8, 12.10.1),and the FID to MSTID Allocation Table (8.9.3, 12.12.2). Hence, changes made to either of these Tables can in turn affect the contents of the MST Configuration Table, and also affect the value of the digest element of the MST Configuration Identifier. The values of all writable objects in this table MUST be retained across reinitializations of the management system. Note that entries will exist in this table only for Bridge components for which the corresponding instance of ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB) has a value of mstp(3). | 1.3.111.2.802.1.1.6.1.10 | not-accessible | current | |
| ieee8021MstpVlanV2Entry OBJECT-TYPE In an MSTP Bridge, a MST Configuration Table entry. | 1.3.111.2.802.1.1.6.1.10.1 | not-accessible | current | |
| ieee8021MstpVlanV2ComponentId OBJECT-TYPE The component identifier is used to distinguish between the multiple virtual Bridge instances within a PBB. In simple situations where there is only a single component the default value is 1. | 1.3.111.2.802.1.1.6.1.10.1.1 | IEEE8021PbbComponentIdentifier | not-accessible | current |
| ieee8021MstpVlanV2Id OBJECT-TYPE In an MSTP Bridge, the VID of the entry in the MST Configuration Table. | 1.3.111.2.802.1.1.6.1.10.1.2 | IEEE8021VlanIndex | not-accessible | current |
| ieee8021MstpVlanV2MstId OBJECT-TYPE In an MSTP Bridge, the MSTID value corresponding to the VID of the entry in the MST Configuration Table. In an SPT Bridge, a value of 4095 is used to indicate SPVIDs. | 1.3.111.2.802.1.1.6.1.10.1.3 | Unsigned32 (0..4095) | read-only | current |
| ieee8021MstpConformance OBJECT-IDENTITY | 1.3.111.2.802.1.1.6.2 | |||
| ieee8021MstpGroups OBJECT-IDENTITY | 1.3.111.2.802.1.1.6.2.1 | |||
| ieee8021MstpCompliances OBJECT-IDENTITY | 1.3.111.2.802.1.1.6.2.2 |
Conformance
| Name | OID | Status |
|---|---|---|
| ieee8021MstpCistGroup OBJECT-GROUP Objects for the CIST group | 1.3.111.2.802.1.1.6.2.1.1 | current |
| ieee8021MstpGroup OBJECT-GROUP Objects for the MST group | 1.3.111.2.802.1.1.6.2.1.2 | current |
| ieee8021MstpCistPortGroup OBJECT-GROUP Objects for the CIST Port group | 1.3.111.2.802.1.1.6.2.1.3 | current |
| ieee8021MstpPortGroup OBJECT-GROUP Objects for the MST Port group | 1.3.111.2.802.1.1.6.2.1.4 | current |
| ieee8021MstpFidToMstiGroup OBJECT-GROUP Objects for the MST FID to MSTID Allocation Table group | 1.3.111.2.802.1.1.6.2.1.5 | deprecated |
| ieee8021MstpVlanGroup OBJECT-GROUP Objects for the MST Configuration Table group | 1.3.111.2.802.1.1.6.2.1.6 | deprecated |
| ieee8021MstpConfigIdGroup OBJECT-GROUP Objects for the MST Configuration Identifier group | 1.3.111.2.802.1.1.6.2.1.7 | current |
| ieee8021MstpCistPortExtensionGroup OBJECT-GROUP Objects for the CIST Port Extension group for fragile Bridges | 1.3.111.2.802.1.1.6.2.1.8 | current |
| ieee8021MstpFidToMstiV2Group OBJECT-GROUP Objects for the MST FID to MSTID Allocation Table group for SPB | 1.3.111.2.802.1.1.6.2.1.9 | current |
| ieee8021MstpVlanV2Group OBJECT-GROUP Objects for the MST Configuration Table group for SPB | 1.3.111.2.802.1.1.6.2.1.10 | current |
| ieee8021MstpCompliance MODULE-COMPLIANCE The compliance statement for devices supporting Multiple Spanning Tree as defined in 13 of IEEE Std 802.1Q. | 1.3.111.2.802.1.1.6.2.2.1 | deprecated |
| ieee8021MstpComplianceV2 MODULE-COMPLIANCE The compliance statement for devices supporting Multiple Spanning Tree as defined in 13 of IEEE Std 802.1Q. | 1.3.111.2.802.1.1.6.2.2.2 | current |