IEEE8021-EVB-MIB
- Registered at
- 1.3.111.2.802.1.1.24
- Last updated
- 2022-11-08 00:00
- Organization
- IEEE 802.1 Working Group
- Revisions
- 2022-11-08 00:00, 2018-07-01 00:00, 2014-12-15 00:00, 2012-02-15 00:00
- Namespace
- standard
- Source file
IEEE8021-EVB-MIB- Digest
sha256:0e88e92ad03af035e5d389f6909e9f4a889ee3f8d6f540c68cd1005f1a50496d
Description
The EVB MIB module for managing devices that support Edge Virtual Bridging. Unless otherwise indicated, the references in this MIB module are to IEEE Std 802.1Q-2022. Copyright (C) IEEE (2022). This version of this MIB module is part of IEEE Std 802.1Q; see that standard for full legal notices.
Contact
WG-URL: http://www.ieee802.org/1/ WG-EMail: stds-802-1-l@ieee.org Contact: IEEE 802.1 Working Group Chair Postal: C/O IEEE 802.1 Working Group IEEE Standards Association 445 Hoes Lane Piscataway, NJ 08854 USA E-mail: stds-802-1-chairs@ieee.org
Imports
| From | Symbols |
|---|---|
| IEEE8021-BRIDGE-MIB | ieee8021BridgePhyPort |
| IEEE8021-TC-MIB | IEEE8021BridgePortNumber, IEEE8021PbbComponentIdentifier, ieee802dot1mibs |
| IF-MIB | InterfaceIndexOrZero |
| Q-BRIDGE-MIB | VlanIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Counter32, Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TimeTicks, Unsigned32, iso |
| SNMPv2-TC | DisplayString, MacAddress, RowStatus, StorageType, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
BRIDGE-MIB IANAifType-MIB IEEE8021-BRIDGE-MIB IEEE8021-EVB-MIB IEEE8021-TC-MIB IF-MIB P-BRIDGE-MIB Q-BRIDGE-MIB RFC1158-MIB RFC1271-MIB RMON-MIB RMON2-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-TC TOKEN-RING-RMON-MIB
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ieee8021BridgeEvbNotifications OBJECT-IDENTITY | 1.3.111.2.802.1.1.24.0 | |||
| ieee8021BridgeEvbObjects OBJECT-IDENTITY | 1.3.111.2.802.1.1.24.1 | |||
| ieee8021BridgeEvbSys OBJECT-IDENTITY | 1.3.111.2.802.1.1.24.1.1 | |||
| ieee8021BridgeEvbSysType OBJECT-TYPE The evbSysType determines if this is an EVB Bridge or EVB station. | 1.3.111.2.802.1.1.24.1.1.1 | INTEGER {evbBridge(1), evbStation(2)} | read-only | current |
| ieee8021BridgeEvbSysNumExternalPorts OBJECT-TYPE The evbSysNumExternalPorts parameter indicates how many externally accessible port are available. | 1.3.111.2.802.1.1.24.1.1.2 | Unsigned32 (1..4095) | read-only | current |
| ieee8021BridgeEvbSysEvbLldpTxEnable OBJECT-TYPE This object is used to initialize the LLDP EVB objects for new SBPs and URPS. When set to 'true' a new SBP or URP will place the local EVB objects in the LLDP nearest Customer database; when set to 'false' a new SBP or URP will not place the local EVB objects in the LLDP database. | 1.3.111.2.802.1.1.24.1.1.3 | TruthValue | read-write | current |
| ieee8021BridgeEvbSysEvbLldpManual OBJECT-TYPE This object is used to initialize the LLDP EVB objects for new SBPs and URPS. When set to 'false' the operating configuration will be determined by the comparison between the local and remote LLDP EVB objects (automatic), regardless of the setting of ieee8021BridgeEvbSysLldpTxEnable. When ieee8021BridgeEvbSysLldpManual is 'true' the configuration will be determined by the setting of the local EVB objects only (manual). | 1.3.111.2.802.1.1.24.1.1.4 | TruthValue | read-write | current |
| ieee8021BridgeEvbSysEvbLldpGidCapable OBJECT-TYPE The value of this object is used as the default value of the BGID or SGID bit of the EVB LLDP TLV string. | 1.3.111.2.802.1.1.24.1.1.5 | TruthValue | read-write | current |
| ieee8021BridgeEvbSysEcpAckTimer OBJECT-TYPE A value indicating the Bridge Proposed ECP ackTimer. | 1.3.111.2.802.1.1.24.1.1.6 | Integer32 | read-write | deprecated |
| ieee8021BridgeEvbSysEcpMaxRetries OBJECT-TYPE A value indicating the Bridge ECP maxRetries. | 1.3.111.2.802.1.1.24.1.1.7 | Integer32 (0..7) | read-write | current |
| ieee8021BridgeEvbSysVdpDfltRsrcWaitDelay OBJECT-TYPE A value indicating the Bridge Resource VDP Timeout. | 1.3.111.2.802.1.1.24.1.1.8 | Integer32 | read-write | deprecated |
| ieee8021BridgeEvbSysVdpDfltReinitKeepAlive OBJECT-TYPE A value indicating the Bridge Proposed VDP Keep Alive Timeout. | 1.3.111.2.802.1.1.24.1.1.9 | Integer32 | read-write | deprecated |
| ieee8021BridgeEvbSbpTable OBJECT-TYPE A table that contains Station-facing Bridge Port (SBP) details. | 1.3.111.2.802.1.1.24.1.1.10 | not-accessible | current | |
| ieee8021BridgeEvbSbpEntry OBJECT-TYPE A list of objects describing SBP. | 1.3.111.2.802.1.1.24.1.1.10.1 | not-accessible | current | |
| ieee8021BridgeEvbSbpComponentID OBJECT-TYPE The SBP component ID | 1.3.111.2.802.1.1.24.1.1.10.1.1 | IEEE8021PbbComponentIdentifier | not-accessible | current |
| ieee8021BridgeEvbSbpPortNumber OBJECT-TYPE The SBP port number. | 1.3.111.2.802.1.1.24.1.1.10.1.2 | IEEE8021BridgePortNumber | not-accessible | current |
| ieee8021BridgeEvbSbpLldpManual OBJECT-TYPE The evbSbpLldpManual parameter switches EVB TLVs to manual mode. In manual mode the running parameters are determined solely from the local LLDP database values. | 1.3.111.2.802.1.1.24.1.1.10.1.3 | TruthValue | read-write | current |
| ieee8021BridgeEvbSbpVdpOperRsrcWaitDelay OBJECT-TYPE The value used to initialize the waitWhile timer (41.5.5.7) by the station VDP state machine when the state machine is waiting for a response. | 1.3.111.2.802.1.1.24.1.1.10.1.4 | Unsigned32 | read-only | deprecated |
| ieee8021BridgeEvbSbpVdpOperReinitKeepAlive OBJECT-TYPE The value used to initialize the waitWhile timer (41.5.5.5) by the station VDP state machine in order to determine when to transmit a keep alive message. | 1.3.111.2.802.1.1.24.1.1.10.1.5 | Unsigned32 | read-only | deprecated |
| ieee8021BridgeEvbSbpVdpOperToutKeepAlive OBJECT-TYPE The value used to initialize the waitWhile timer (41.5.5.13) by the EVBCB VDP state machine in order to determine when to transmit a keep alive message. | 1.3.111.2.802.1.1.24.1.1.10.1.6 | Unsigned32 | read-only | current |
| ieee8021BridgeEvbSbpVdpOperRsrcWaitDelayExp OBJECT-TYPE The exponent of 2 used to calculate the value to initialize the waitWhile timer (41.5.5.7) by the station VDP state machine when the state machine is waiting for a response. | 1.3.111.2.802.1.1.24.1.1.10.1.7 | Unsigned32 (0..31) | read-only | current |
| ieee8021BridgeEvbSbpVdpOperReinitKeepAliveExp OBJECT-TYPE The exponent of 2 used to calculate the value to initialize the waitWhile timer (41.5.5.5) by the station VDP state machine in order to determine when to transmit a keep alive message. | 1.3.111.2.802.1.1.24.1.1.10.1.8 | Unsigned32 (0..31) | read-only | current |
| ieee8021BridgeEvbSysEcpDfltAckTimerExp OBJECT-TYPE The exponent of 2 indicating the Bridge Proposed ECP ackTimer in tens of microseconds. | 1.3.111.2.802.1.1.24.1.1.11 | Integer32 (0..31) | read-write | current |
| ieee8021BridgeEvbSysVdpDfltRsrcWaitDelayExp OBJECT-TYPE The exponent of 2 indicating the Bridge Resource VDP Timeout in tens of microseconds. | 1.3.111.2.802.1.1.24.1.1.12 | Integer32 (0..31) | read-write | current |
| ieee8021BridgeEvbSysVdpDfltReinitKeepAliveExp OBJECT-TYPE The exponent of 2 indicating the Bridge Proposed VDP Keep Alive Timeout in tens of microseconds. | 1.3.111.2.802.1.1.24.1.1.13 | Integer32 (0..31) | read-write | current |
| ieee8021BridgeEvbVSIDBObjects OBJECT-IDENTITY | 1.3.111.2.802.1.1.24.1.2 | |||
| ieee8021BridgeEvbVSIDBTable OBJECT-TYPE A table that contains database of the active Virtual Station Interfaces. | 1.3.111.2.802.1.1.24.1.2.1 | not-accessible | current | |
| ieee8021BridgeEvbVSIDBEntry OBJECT-TYPE A list of objects containing database of the active Virtual Station Interfaces. | 1.3.111.2.802.1.1.24.1.2.1.1 | not-accessible | current | |
| ieee8021BridgeEvbVSIComponentID OBJECT-TYPE The evbVSIComponentID is the ComponentID for the C-VLAN component of the EVB Bridge or for the edge relay of the EVB station. | 1.3.111.2.802.1.1.24.1.2.1.1.1 | IEEE8021PbbComponentIdentifier | not-accessible | current |
| ieee8021BridgeEvbVSIPortNumber OBJECT-TYPE The evbVSIPortNumber is the Port Number for the SBP or URP where the VSI is accessed. | 1.3.111.2.802.1.1.24.1.2.1.1.2 | IEEE8021BridgePortNumber | not-accessible | current |
| ieee8021BridgeEvbVSIIDType OBJECT-TYPE This object specifies the VSIID Type for the VSIID in the DCN | 1.3.111.2.802.1.1.24.1.2.1.1.3 | INTEGER {vsiidIpv4(1), vsiidIpv6(2), vsiidMAC(3), vsiidLocal(4), vsiidUUID(5)} | not-accessible | current |
| ieee8021BridgeEvbVSIID OBJECT-TYPE This object specifies the VSIID that uniquely identifies the VSI in the DCN | 1.3.111.2.802.1.1.24.1.2.1.1.4 | OCTET STRING (SIZE(16)) | not-accessible | current |
| ieee8021BridgeEvbVSITimeSinceCreate OBJECT-TYPE This object specifies the time since creation | 1.3.111.2.802.1.1.24.1.2.1.1.5 | Unsigned32 | read-only | current |
| ieee8021BridgeEvbVsiVdpOperCmd OBJECT-TYPE This object identifies the type of TLV. | 1.3.111.2.802.1.1.24.1.2.1.1.6 | INTEGER {preAssociate(1), preAssociateWithRsrcReservation(2), associate(3), deAssociate(4)} | read-only | current |
| ieee8021BridgeEvbVsiOperRevert OBJECT-TYPE The evbOperRevert status indicator shows the most recent value of the KEEP indicator from the VDP protocol exchange. | 1.3.111.2.802.1.1.24.1.2.1.1.7 | TruthValue | read-only | current |
| ieee8021BridgeEvbVsiOperHard OBJECT-TYPE The evbVsiHard status indicator shows the most recent value of the HARD indicator from the VDP protocol exchange. | 1.3.111.2.802.1.1.24.1.2.1.1.8 | TruthValue | read-only | current |
| ieee8021BridgeEvbVsiOperReason OBJECT-TYPE This object indicates the outcome of a request. | 1.3.111.2.802.1.1.24.1.2.1.1.9 | Bits {success(0), invalidFormat(1), insufficientResources(2), otherfailure(3)} | read-only | current |
| ieee8021BridgeEvbVSIMgrID OBJECT-TYPE This object identifies the VSI Manager with a database that holds the detailed VSI type and or instance definitions. | 1.3.111.2.802.1.1.24.1.2.1.1.10 | OCTET STRING (SIZE(1)) | read-only | deprecated |
| ieee8021BridgeEvbVSIType OBJECT-TYPE The VTID is an integer value used to identify a pre-configured set of controls and attributes that are associated with a set of VSIs. | 1.3.111.2.802.1.1.24.1.2.1.1.11 | Integer32 | read-only | current |
| ieee8021BridgeEvbVSITypeVersion OBJECT-TYPE The VSI Type Version is an integer identifier designating the expected/desired VTID version. The VTID version allows a VSI Manager Database to contain multiple versions of a given VSI Type, allowing smooth migration to newer VSI types. | 1.3.111.2.802.1.1.24.1.2.1.1.12 | OCTET STRING (SIZE(1)) | read-only | current |
| ieee8021BridgeEvbVSIMvFormat OBJECT-TYPE This object specifies the MAC/VLAN format. basic - Basic MAC/VLAN format partial - Partial MAC/VLAN format vlanOnly - Vlan-only MAC/VLAN format | 1.3.111.2.802.1.1.24.1.2.1.1.13 | INTEGER {basic(1), partial(2), vlanOnly(3)} | read-only | deprecated |
| ieee8021BridgeEvbVSINumMACs OBJECT-TYPE This object specifies the the number of MAC address/VLAN ID pairs contained in the repeated portion of the MAC/VLANs field in the VDP TLV. | 1.3.111.2.802.1.1.24.1.2.1.1.14 | Integer32 | read-only | current |
| ieee8021BridgeEvbVDPMachineState OBJECT-TYPE This object specifies the VDP state machine. | 1.3.111.2.802.1.1.24.1.2.1.1.15 | INTEGER {preAssociate(1), preAssociateWithRsrcReservation(2), associate(3), deAssociate(4)} | read-only | current |
| ieee8021BridgeEvbVDPCommandsSucceeded OBJECT-TYPE This object specifies the VDP number of successful commands since creation. | 1.3.111.2.802.1.1.24.1.2.1.1.16 | Counter32 | read-only | current |
| ieee8021BridgeEvbVDPCommandsFailed OBJECT-TYPE This object specifies the VDP number of failed commands since creation | 1.3.111.2.802.1.1.24.1.2.1.1.17 | Counter32 | read-only | current |
| ieee8021BridgeEvbVDPCommandReverts OBJECT-TYPE This object specifies the VDP command reverts since creation | 1.3.111.2.802.1.1.24.1.2.1.1.18 | Counter32 | read-only | current |
| ieee8021BridgeEvbVDPCounterDiscontinuity OBJECT-TYPE The time (in hundredths of a second) since the last counter discontinuity for any of the counters in the row. | 1.3.111.2.802.1.1.24.1.2.1.1.19 | TimeTicks | read-only | current |
| ieee8021BridgeEvbVSIMgrID16 OBJECT-TYPE This object identifies the VSI Manager with a database that holds the detailed VSI type and or instance definitions. | 1.3.111.2.802.1.1.24.1.2.1.1.20 | OCTET STRING (SIZE(16)) | read-only | current |
| ieee8021BridgeEvbVSIFilterFormat OBJECT-TYPE This object specifies the MAC/VLAN format: vid (see 41.2.9.1) macVid (see 41.2.9.2) groupidVid (see 41.2.9.3) groupidMacVid (see 41.2.9.4) | 1.3.111.2.802.1.1.24.1.2.1.1.21 | INTEGER {vid(1), macVid(2), groupidVid(3), groupidMacVid(4)} | read-only | current |
| ieee8021BridgeEvbVSIDBMacTable OBJECT-TYPE A table that contains database of the active Virtual Station Interfaces. | 1.3.111.2.802.1.1.24.1.2.2 | not-accessible | current | |
| ieee8021BridgeEvbVSIDBMacEntry OBJECT-TYPE A list of objects containing database of the MAC/VLANs associated with Virtual Station Interfaces. | 1.3.111.2.802.1.1.24.1.2.2.1 | not-accessible | current | |
| ieee8021BridgeEvbGroupID OBJECT-TYPE Group ID | 1.3.111.2.802.1.1.24.1.2.2.1.1 | Unsigned32 | not-accessible | current |
| ieee8021BridgeEvbVSIMac OBJECT-TYPE The mac-address part of the MAC/VLANs for a VSI. | 1.3.111.2.802.1.1.24.1.2.2.1.2 | MacAddress | not-accessible | current |
| ieee8021BridgeEvbVSIVlanId OBJECT-TYPE The Vlan ID part of the MAC/VLANs for a VSI. | 1.3.111.2.802.1.1.24.1.2.2.1.3 | VlanIndex | read-only | current |
| ieee8021BridgeEvbSChannelObjects OBJECT-IDENTITY | 1.3.111.2.802.1.1.24.1.3 | |||
| ieee8021BridgeEvbUAPConfigTable OBJECT-TYPE A table that contains configuration parameters for UAP. | 1.3.111.2.802.1.1.24.1.3.1 | not-accessible | current | |
| ieee8021BridgeEvbUAPConfigEntry OBJECT-TYPE A list of objects containing information to configure the attributes for UAP. | 1.3.111.2.802.1.1.24.1.3.1.1 | not-accessible | current | |
| ieee8021BridgeEvbUAPComponentId OBJECT-TYPE The ComponentID of the port for the UAP. | 1.3.111.2.802.1.1.24.1.3.1.1.1 | IEEE8021PbbComponentIdentifier | read-only | current |
| ieee8021BridgeEvbUAPPort OBJECT-TYPE The port number of the port for the UAP. | 1.3.111.2.802.1.1.24.1.3.1.1.2 | IEEE8021BridgePortNumber | read-only | current |
| ieee8021BridgeEvbUapConfigIfIndex OBJECT-TYPE The value of the instance of the IfIndex object, defined in the IF-MIB, for the interface corresponding to this port, or the value 0 if the port has not been bound to an underlying frame source and sink. | 1.3.111.2.802.1.1.24.1.3.1.1.3 | InterfaceIndexOrZero | read-only | current |
| ieee8021BridgeEvbUAPSchCdcpAdminEnable OBJECT-TYPE Administrative status of CDCP. | 1.3.111.2.802.1.1.24.1.3.1.1.4 | INTEGER {enable(1), disable(2)} | read-create | current |
| ieee8021BridgeEvbUAPSchAdminCDCPRole OBJECT-TYPE The administratively configured value for the local port's role parameter. The value of AdminRole is not reflected in the S-channel TLV. The AdminRole may take the value S or B. S indicates the sender is unwilling to accept S-channels configuration (mode, # channels supported, channel index) from its neighbor and that the sender is willing to accept SVID assignments from the neighbor. Stations usually take the S role. B indicates the sender is willing to accept S-channels configuration (mode, # channels supported, channel index) from its neighbor and that the sender is willing do the best it can to fill the SVID assignments from the neighbor. Bridges usually take the B role. | 1.3.111.2.802.1.1.24.1.3.1.1.5 | INTEGER {cdcpRoleB(1), cdcpRoleS(2)} | read-create | current |
| ieee8021BridgeEvbUAPSchAdminCDCPChanCap OBJECT-TYPE The administratively configured value for the Number of Channels supported parameter. This value is included as the ChanCap parameter in the S-channel TLV. | 1.3.111.2.802.1.1.24.1.3.1.1.6 | Integer32 (1..167) | read-create | current |
| ieee8021BridgeEvbUAPSchOperCDCPChanCap OBJECT-TYPE The operational value for the Number of Channels supported parameter. This value is included as the ChnCap parameter in the S-channel TLV. | 1.3.111.2.802.1.1.24.1.3.1.1.7 | Integer32 (1..167) | read-only | current |
| ieee8021BridgeEvbUAPSchAdminCDCPSVIDPoolLow OBJECT-TYPE Determines the lowest S-VIDs available for assignment by CDCP. | 1.3.111.2.802.1.1.24.1.3.1.1.8 | VlanIndex | read-create | current |
| ieee8021BridgeEvbUAPSchAdminCDCPSVIDPoolHigh OBJECT-TYPE Determines the highest S-VIDs available for assignment by CDCP. | 1.3.111.2.802.1.1.24.1.3.1.1.9 | VlanIndex | read-create | current |
| ieee8021BridgeEvbUAPSchOperState OBJECT-TYPE The current running state of CDCP. | 1.3.111.2.802.1.1.24.1.3.1.1.10 | INTEGER {running(1), notRunning(2)} | read-only | current |
| ieee8021BridgeEvbSchCdcpRemoteEnabled OBJECT-TYPE CDCP state for the remote S-channel. | 1.3.111.2.802.1.1.24.1.3.1.1.11 | INTEGER {enable(1), disable(2)} | read-only | current |
| ieee8021BridgeEvbSchCdcpRemoteRole OBJECT-TYPE The value for the remote port's role parameter. | 1.3.111.2.802.1.1.24.1.3.1.1.12 | INTEGER {cdcpRoleB(1), cdcpRoleS(2)} | read-only | current |
| ieee8021BridgeEvbUAPConfigStorageType OBJECT-TYPE The storage type for this row. Rows in this table that were created through an external process may have a storage type of readOnly or permanent. For a storage type of permanent, none of the columns have to be writable. | 1.3.111.2.802.1.1.24.1.3.1.1.13 | StorageType | read-create | current |
| ieee8021BridgeEvbUAPConfigRowStatus OBJECT-TYPE RowStatus for creating a UAP table entry. | 1.3.111.2.802.1.1.24.1.3.1.1.14 | RowStatus | read-create | current |
| ieee8021BridgeEvbCAPConfigTable OBJECT-TYPE A table that contains configuration information for the S-Channel Access Ports (CAP). | 1.3.111.2.802.1.1.24.1.3.2 | not-accessible | current | |
| ieee8021BridgeEvbCAPConfigEntry OBJECT-TYPE A list of objects containing information for the S-Channel Access Ports (CAP) | 1.3.111.2.802.1.1.24.1.3.2.1 | not-accessible | current | |
| ieee8021BridgeEvbSchID OBJECT-TYPE This object represents the SVID for a ieee8021BridgeEvbSysType of evbBridge and a SCID(S-Channel ID) for a ieee8021BridgeEvbSysType of evbStation. | 1.3.111.2.802.1.1.24.1.3.2.1.1 | Unsigned32 (1..4094) | not-accessible | current |
| ieee8021BridgeEvbCAPComponentId OBJECT-TYPE Component ID for S-channel Access Port. | 1.3.111.2.802.1.1.24.1.3.2.1.2 | IEEE8021PbbComponentIdentifier | read-only | current |
| ieee8021BridgeEvbCapConfigIfIndex OBJECT-TYPE The value of the instance of the IfIndex object, defined in the IF-MIB, for the interface corresponding to this port, or the value 0 if the port has not been bound to an underlying frame source and sink. The underlying IfEntry indexed by this column MUST be persistent across reinitializations of the management system. | 1.3.111.2.802.1.1.24.1.3.2.1.3 | InterfaceIndexOrZero | read-only | current |
| ieee8021BridgeEvbCAPPort OBJECT-TYPE Port number for the S-Channel Access Port. | 1.3.111.2.802.1.1.24.1.3.2.1.4 | IEEE8021BridgePortNumber | read-only | current |
| ieee8021BridgeEvbCAPSChannelID OBJECT-TYPE S-Channel ID (SCID) for this CAP. | 1.3.111.2.802.1.1.24.1.3.2.1.5 | Unsigned32 | read-only | current |
| ieee8021BridgeEvbCAPAssociateSBPOrURPCompID OBJECT-TYPE Component ID of the Server Edge Port to be associated with the CAP. | 1.3.111.2.802.1.1.24.1.3.2.1.6 | IEEE8021PbbComponentIdentifier | read-write | current |
| ieee8021BridgeEvbCAPAssociateSBPOrURPPort OBJECT-TYPE Port number of the Server Edge Port to be associated with the CAP. | 1.3.111.2.802.1.1.24.1.3.2.1.7 | IEEE8021BridgePortNumber | read-write | current |
| ieee8021BridgeEvbCAPRowStatus OBJECT-TYPE RowStatus to create/destroy this table. | 1.3.111.2.802.1.1.24.1.3.2.1.8 | RowStatus | read-create | current |
| ieee8021BridgeEvbURPTable OBJECT-TYPE A table that contains configuration information for the Uplink Relay Ports(URP). | 1.3.111.2.802.1.1.24.1.3.3 | not-accessible | current | |
| ieee8021BridgeEvbURPEntry OBJECT-TYPE A list of objects containing information for the Uplink Relay Ports(URP). | 1.3.111.2.802.1.1.24.1.3.3.1 | not-accessible | current | |
| ieee8021BridgeEvbURPComponentId OBJECT-TYPE Component ID that the URP belongs to. | 1.3.111.2.802.1.1.24.1.3.3.1.1 | IEEE8021PbbComponentIdentifier | not-accessible | current |
| ieee8021BridgeEvbURPPort OBJECT-TYPE port number of the urp. | 1.3.111.2.802.1.1.24.1.3.3.1.2 | IEEE8021BridgePortNumber | not-accessible | current |
| ieee8021BridgeEvbURPIfIndex OBJECT-TYPE The value of the instance of the IfIndex object, defined in the IF-MIB, for the interface corresponding to this port, or the value 0 if the port has not been bound to an underlying frame source and sink. It is an implementation specific decision as to whether this object may be modified if it has been created or if 0 is a legal value. The underlying IfEntry indexed by this column MUST be persistent across reinitializations of the management system. | 1.3.111.2.802.1.1.24.1.3.3.1.3 | InterfaceIndexOrZero | read-write | current |
| ieee8021BridgeEvbURPBindToISSPort OBJECT-TYPE The evbURPBindToISSPort is the ISS Port Number where the URP is attached. This binding is optional and only required in some systems. | 1.3.111.2.802.1.1.24.1.3.3.1.4 | IEEE8021BridgePortNumber | read-write | current |
| ieee8021BridgeEvbURPLldpManual OBJECT-TYPE The evbUrpLldpManual parameter control how the EVB TLV determines the operating values for parameters. When set TRUE only the local EVB TLV will be used to determine the parameters. | 1.3.111.2.802.1.1.24.1.3.3.1.6 | TruthValue | read-write | current |
| ieee8021BridgeEvbURPVdpOperRsrcWaitDelay OBJECT-TYPE The parameter evbURPVdpOperRsrcWaitDelay is the exponent of 2 used to set the VDP resourceWaitDelay timer at the EVB Bridge. | 1.3.111.2.802.1.1.24.1.3.3.1.9 | Unsigned32 | read-only | deprecated |
| ieee8021BridgeEvbURPVdpOperRespWaitDelay OBJECT-TYPE The evbUrpVdpOperRespWaitDelay is how long a EVb station VDP will wait for a response from the EVB Bridge VDP. | 1.3.111.2.802.1.1.24.1.3.3.1.10 | Unsigned32 | read-write | current |
| ieee8021BridgeEvbURPVdpOperReinitKeepAlive OBJECT-TYPE The evbURPVdpOperReinitKeepAlive is the exponent of 2 used to determine the time interval of Keep Alives transmitted by the EVB station. | 1.3.111.2.802.1.1.24.1.3.3.1.11 | Unsigned32 | read-write | deprecated |
| ieee8021BridgeEvbURPVdpOperRsrcWaitDelayExp OBJECT-TYPE The parameter evbURPVdpOperRsrcWaitDelay is the exponent of 2 used to set the VDP resourceWaitDelay timer at the EVB Bridge. | 1.3.111.2.802.1.1.24.1.3.3.1.12 | Unsigned32 (0..31) | read-only | current |
| ieee8021BridgeEvbURPVdpOperReinitKeepAliveExp OBJECT-TYPE The evbURPVdpOperReinitKeepAlive is the exponent of 2 used to determine the time interval of Keep Alives transmitted by the EVB station. | 1.3.111.2.802.1.1.24.1.3.3.1.13 | Unsigned32 (0..31) | read-write | current |
| ieee8021BridgeEvbEcpTable OBJECT-TYPE A table that contains configuration information for the Edge Control Protocol (ECP). | 1.3.111.2.802.1.1.24.1.3.4 | not-accessible | current | |
| ieee8021BridgeEvbEcpEntry OBJECT-TYPE A list of objects containing information for theEdge Control Protocol (ECP). | 1.3.111.2.802.1.1.24.1.3.4.1 | not-accessible | current | |
| ieee8021BridgeEvbEcpComponentId OBJECT-TYPE Component ID . | 1.3.111.2.802.1.1.24.1.3.4.1.1 | IEEE8021PbbComponentIdentifier | not-accessible | current |
| ieee8021BridgeEvbEcpPort OBJECT-TYPE Port number. | 1.3.111.2.802.1.1.24.1.3.4.1.2 | IEEE8021BridgePortNumber | not-accessible | current |
| ieee8021BridgeEvbEcpOperAckTimerInit OBJECT-TYPE The initial value used to initialize ackTimer (43.3.6.1). | 1.3.111.2.802.1.1.24.1.3.4.1.3 | Unsigned32 | read-only | deprecated |
| ieee8021BridgeEvbEcpOperMaxRetries OBJECT-TYPE This integer variable defines the maximum number of times that the ECP transmit state machine will retry a transmission if no ACK is received. | 1.3.111.2.802.1.1.24.1.3.4.1.4 | Unsigned32 | read-only | current |
| ieee8021BridgeEvbEcpTxFrameCount OBJECT-TYPE The evbECPTxFrameCount is the number of ECP frame transmitted since ECP was instanciated. | 1.3.111.2.802.1.1.24.1.3.4.1.5 | Counter32 | read-only | current |
| ieee8021BridgeEvbEcpTxRetryCount OBJECT-TYPE The evbECPTxRetryCount is the number of times ECP re-tried transmission since ECP was instanciated. | 1.3.111.2.802.1.1.24.1.3.4.1.6 | Counter32 | read-only | current |
| ieee8021BridgeEvbEcpTxFailures OBJECT-TYPE The evbECPTxFailures is the number of times ECP failed to successfully deliver a frame since ECP was instanciated. | 1.3.111.2.802.1.1.24.1.3.4.1.7 | Counter32 | read-only | current |
| ieee8021BridgeEvbEcpRxFrameCount OBJECT-TYPE The evbECPRxFrameCount is the number of frames received since ECP was instanciated. | 1.3.111.2.802.1.1.24.1.3.4.1.8 | Counter32 | read-only | current |
| ieee8021BridgeEvbEcpOperAckTimerInitExp OBJECT-TYPE The initial value used to initialize ackTimer. Expressed as exp where 10*2exp microseconds is the duration of the ack timer(43.3.6.1). | 1.3.111.2.802.1.1.24.1.3.4.1.9 | Unsigned32 (0..31) | read-only | current |
| ieee8021BridgeEvbConformance OBJECT-IDENTITY | 1.3.111.2.802.1.1.24.2 | |||
| ieee8021BridgeEvbGroups OBJECT-IDENTITY | 1.3.111.2.802.1.1.24.2.1 | |||
| ieee8021BridgeEvbCompliances OBJECT-IDENTITY | 1.3.111.2.802.1.1.24.2.2 |
Conformance
| Name | OID | Status |
|---|---|---|
| ieee8021BridgeEvbSysGroup OBJECT-GROUP The collection of objects used to represent a EVB management objects. | 1.3.111.2.802.1.1.24.2.1.1 | deprecated |
| ieee8021BridgeEvbSbpGroup OBJECT-GROUP The collection of objects used to represent a SBP management objects. | 1.3.111.2.802.1.1.24.2.1.3 | deprecated |
| ieee8021BridgeEvbVSIDBGroup OBJECT-GROUP The collection of objects used to represent a EVB VSI DB table. | 1.3.111.2.802.1.1.24.2.1.4 | deprecated |
| ieee8021BridgeEvbUAPGroup OBJECT-GROUP The collection of objects used to represent a EVB UAP table. | 1.3.111.2.802.1.1.24.2.1.5 | current |
| ieee8021BridgeEvbCAPConfigGroup OBJECT-GROUP The collection of objects used to represent a EVB CAP management objects. | 1.3.111.2.802.1.1.24.2.1.6 | current |
| ieee8021BridgeEvbsURPGroup OBJECT-GROUP The collection of objects used to represent a EVBS URP management objects. | 1.3.111.2.802.1.1.24.2.1.7 | deprecated |
| ieee8021BridgeEvbEcpGroup OBJECT-GROUP The collection of objects used to represent a EVB CAP management objects. | 1.3.111.2.802.1.1.24.2.1.8 | deprecated |
| ieee8021BridgeEvbSysV2Group OBJECT-GROUP The collection of objects used to represent a EVB management objects. | 1.3.111.2.802.1.1.24.2.1.9 | current |
| ieee8021BridgeEvbSbpV2Group OBJECT-GROUP The collection of objects used to represent a SBP management objects. | 1.3.111.2.802.1.1.24.2.1.10 | current |
| ieee8021BridgeEvbVSIDBV2Group OBJECT-GROUP The collection of objects used to represent a EVB VSI DB table. | 1.3.111.2.802.1.1.24.2.1.11 | current |
| ieee8021BridgeEvbsURPV2Group OBJECT-GROUP The collection of objects used to represent a EVBS URP management objects. | 1.3.111.2.802.1.1.24.2.1.12 | current |
| ieee8021BridgeEvbEcpV2Group OBJECT-GROUP The collection of objects used to represent a EVB CAP management objects. | 1.3.111.2.802.1.1.24.2.1.13 | current |
| ieee8021BridgeEvbbCompliance MODULE-COMPLIANCE The compliance statement for devices supporting EVB as defined in IEEE 802.1Q. | 1.3.111.2.802.1.1.24.2.2.1 | deprecated |
| ieee8021BridgeEvbsCompliance MODULE-COMPLIANCE The compliance statement for devices supporting EVBS as defined in IEEE 802.1Q. | 1.3.111.2.802.1.1.24.2.2.2 | deprecated |
| ieee8021BridgeEvbbComplianceV2 MODULE-COMPLIANCE The compliance statement for devices supporting EVB as defined in IEEE 802.1Q. | 1.3.111.2.802.1.1.24.2.2.3 | current |
| ieee8021BridgeEvbsComplianceV2 MODULE-COMPLIANCE The compliance statement for devices supporting EVBS as defined in IEEE 802.1Q. | 1.3.111.2.802.1.1.24.2.2.4 | current |