MIBs Depot

ICT-SINE-WAVE-INVERTER-MIB

Registered at
1.3.6.1.4.1.39145.12
Namespace
ict
Source file
ICT-SINE-WAVE-INVERTER-MIB
Digest
sha256:c05de5aceec8ccd429102ec5f58129db9b250240ab36025a153a0ad062ffbdcd

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIIpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, TRAP-TYPE, enterprises, iso
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

ICT-SINE-WAVE-INVERTER-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-TC

Objects

NameOIDSyntaxAccessStatus
ictPower
OBJECT-IDENTITY
1.3.6.1.4.1.39145
inverter
OBJECT-IDENTITY
1.3.6.1.4.1.39145.12
deviceModel
OBJECT-TYPE
Model Number
1.3.6.1.4.1.39145.12.1DisplayStringread-onlymandatory
deviceName
OBJECT-TYPE
Site Name
1.3.6.1.4.1.39145.12.2DisplayStringread-onlymandatory
deviceHardware
OBJECT-TYPE
Hardware Version
1.3.6.1.4.1.39145.12.3INTEGER (0..127)read-onlymandatory
deviceFirmware
OBJECT-TYPE
Firmware Version
1.3.6.1.4.1.39145.12.4DisplayStringread-onlymandatory
deviceMacAddress
OBJECT-TYPE
MAC Address
1.3.6.1.4.1.39145.12.5DisplayStringread-onlymandatory
batteryVoltage
OBJECT-TYPE
Battery Voltage (VDC)
1.3.6.1.4.1.39145.12.6DisplayStringread-onlymandatory
inverterVoltage
OBJECT-TYPE
Inverter Output Voltage (VAC)
1.3.6.1.4.1.39145.12.7DisplayStringread-onlymandatory
inverterPower
OBJECT-TYPE
Inverter Output Power (%)
1.3.6.1.4.1.39145.12.8DisplayStringread-onlymandatory
inverterStatus
OBJECT-TYPE
Inverter Output Status ('1' indicates the Inverter Output is ENABLED, and '2' indicates the Inverter Output is DISABLED)
1.3.6.1.4.1.39145.12.9INTEGER {enabled(1), disabled(2)}read-onlymandatory
inverterControl
OBJECT-TYPE
Inverter Output Control (set to '1' to ENABLE the Inverter Output if no alarms are active, set to '2' to DISABLE the Inverter Output)
1.3.6.1.4.1.39145.12.10INTEGER {enabled(1), disabled(2)}read-writemandatory
transferRelayStatus
OBJECT-TYPE
Transfer Relay Status ('1' indicates the Output is connected to the INVERTER, and '2' indicates the Output is connected to the GRID)
1.3.6.1.4.1.39145.12.11INTEGER {inverter(1), grid(2)}read-onlymandatory

Notifications

NameOIDStatus
undervoltageAlarmTrap
NOTIFICATION-TYPE
Trap generated when the Battery Input Undervoltage Alarm is triggered
1.3.6.1.4.1.39145.12.0.101
overvoltageAlarmTrap
NOTIFICATION-TYPE
Trap generated when the Battery Input Overvoltage Alarm is triggered
1.3.6.1.4.1.39145.12.0.102
overtemperatureAlarmTrap
NOTIFICATION-TYPE
Trap generated when the Overtemperature Alarm is triggered
1.3.6.1.4.1.39145.12.0.103
outputFaultAlarmTrap
NOTIFICATION-TYPE
Trap generated when the Inverter Output Fault Alarm is triggered
1.3.6.1.4.1.39145.12.0.104
systemFaultAlarmTrap
NOTIFICATION-TYPE
Trap generated when the System Fault Alarm is triggered
1.3.6.1.4.1.39145.12.0.105
remoteSwitchAlarmTrap
NOTIFICATION-TYPE
Trap generated when the Remote Switch accessory is activated
1.3.6.1.4.1.39145.12.0.106
undervoltageAlarmClear
NOTIFICATION-TYPE
Trap generated when the Battery Input Undervoltage Alarm is cleared
1.3.6.1.4.1.39145.12.0.111
overvoltageAlarmClear
NOTIFICATION-TYPE
Trap generated when the Battery Input Overvoltage Alarm is cleared
1.3.6.1.4.1.39145.12.0.112
overtemperatureAlarmClear
NOTIFICATION-TYPE
Trap generated when the Overtemperature Alarm is cleared
1.3.6.1.4.1.39145.12.0.113
outputFaultAlarmClear
NOTIFICATION-TYPE
Trap generated when the Inverter Output Fault Alarm is cleared
1.3.6.1.4.1.39145.12.0.114
systemFaultAlarmClear
NOTIFICATION-TYPE
Trap generated when the System Fault Alarm is cleared
1.3.6.1.4.1.39145.12.0.115
remoteSwitchAlarmClear
NOTIFICATION-TYPE
Trap generated when the Remote Switch accessory is deactivated
1.3.6.1.4.1.39145.12.0.116
inverterPowerTrap
NOTIFICATION-TYPE
Trap generated when the Output switches to Inverter (Battery) Power
1.3.6.1.4.1.39145.12.0.121
gridPowerTrap
NOTIFICATION-TYPE
Trap generated when the Output switches to Grid Power
1.3.6.1.4.1.39145.12.0.122