IBMESCONCUB-MIB
- Registered at
- 1.3.6.1.4.1.2.6.119.4.14
- Namespace
- ibm
- Source file
IBMESCONCUB-MIB- Digest
sha256:32bbf319aa0b50abc6f627be642993e2865e9f1bf92062a3b0a1f3fb1ca9696b
Imports
| From | Symbols |
|---|---|
| IF-MIB | ifIndex |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, iso |
| SNMPv2-SMI-v1 | Counter32, Integer32, IpAddress, enterprises |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION |
| SNMPv2-TC-v1 | MacAddress |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IANAifType-MIB IBMESCONCUB-MIB IF-MIB SNMPv2-CONF SNMPv2-MIB SNMPv2-SMI SNMPv2-SMI-v1 SNMPv2-TC SNMPv2-TC-v1
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ibmIROCescon OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.119.4.14 | |||
| esconPortData OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.119.4.14.1 | |||
| esconPortTable OBJECT-TYPE Table of objects that describe an ESCON channel port. | 1.3.6.1.4.1.2.6.119.4.14.1.1 | not-accessible | mandatory | |
| esconPortEntry OBJECT-TYPE Table of objects that describe an ESCON channel port. This table is indexed by ifIndex from MIB-II. | 1.3.6.1.4.1.2.6.119.4.14.1.1.1 | not-accessible | mandatory | |
| esconPortInFiberStatus OBJECT-TYPE Status of the fiber into this device from the host: inLoff = the light is off on the fiber into this device from the host inOls = the fiber into this device from the host is in an intermediate state between light-off and light-on inIdle = the fiber into this device from the host is in the light-on state, and is ready to transfer data from the host to this device inUnknown = the agent cannot determine the status of the fiber into this device from the host | 1.3.6.1.4.1.2.6.119.4.14.1.1.1.1 | INTEGER {inLoff(1), inOls(2), inIdle(3), inUnknown(4)} | read-only | mandatory |
| esconPortOutFiberStatus OBJECT-TYPE Status of the fiber out of this device to the host: outDisableReq = out disable obtained; the fiber out of this device into the host is not in the light-on state outDisableForced = out ESCON emits OLS; the fiber out of this device into the host is not in the light-on state outLoffForced = out ESCON forced light-off; the fiber out of this device into the host is not in the light-on state outOls = the fiber out of this device into the host is in an intermediate state between light-off and light-on outOlsforced = out ESCON forced OLS; the fiber out of this device into the host is not in the light-on state outEnable = the fiber out of this device into the host is in the light-on state, and is ready to transfer data from this device to the host outError = the status of the fiber out of this device to the host is none of those listed above. This is a state that should not occur | 1.3.6.1.4.1.2.6.119.4.14.1.1.1.2 | INTEGER {outDisableReq(1), outDisableForced(2), outLoffForced(3), outOls(4), outOlsForced(5), outEnable(6), outError(7)} | read-only | mandatory |
| esconLinkData OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.119.4.14.2 | |||
| esconLinkTable OBJECT-TYPE Table of objects that describe an ESCON channel link. | 1.3.6.1.4.1.2.6.119.4.14.2.1 | not-accessible | mandatory | |
| esconLinkEntry OBJECT-TYPE Table of objects that describe an ESCON channel link. This table is indexed by ifIndex from MIB-II, by host link address, (host) control unit address, and by (host) partition number. | 1.3.6.1.4.1.2.6.119.4.14.2.1.1 | not-accessible | mandatory | |
| esconLinkHostLinkAddress OBJECT-TYPE This address identifies the ESCON Director port to which the optical fiber between the ESCON Director and the host is attached. | 1.3.6.1.4.1.2.6.119.4.14.2.1.1.1 | OCTET STRING (SIZE(1)) | not-accessible | mandatory |
| esconLinkControlUnitAddress OBJECT-TYPE A number identifying a logical control unit within an actual host. | 1.3.6.1.4.1.2.6.119.4.14.2.1.1.2 | OCTET STRING (SIZE(1)) | not-accessible | mandatory |
| esconLinkPartitionNumber OBJECT-TYPE A number identifying a logical host within an actual host. | 1.3.6.1.4.1.2.6.119.4.14.2.1.1.3 | OCTET STRING (SIZE(1)) | not-accessible | mandatory |
| esconLinkStatus OBJECT-TYPE Gives the status of the link: hlpNotEstab = Host Logical Path not established hlpEstab = Host Logical Path established hlpError = Host Logical Path error | 1.3.6.1.4.1.2.6.119.4.14.2.1.1.4 | INTEGER {hlpNotEstab(1), hlpEstab(2), hlpError(3)} | read-only | mandatory |
| esconStationData OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.119.4.14.3 | |||
| esconStationTable OBJECT-TYPE Table of objects that describe an ESCON channel station. | 1.3.6.1.4.1.2.6.119.4.14.3.1 | not-accessible | mandatory | |
| esconStationEntry OBJECT-TYPE Table of objects that describe an ESCON channel station. This table is indexed by ifIndex from MIB-II, by host link address, by (host) control unit address, by (host) partition number, and by ESCON device address. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1 | not-accessible | mandatory | |
| esconStationHostLinkAddress OBJECT-TYPE This address identifies the ESCON Director port to which the optical fiber between the ESCON Director and the host is attached. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.1 | OCTET STRING (SIZE(1)) | not-accessible | mandatory |
| esconStationControlUnitAddress OBJECT-TYPE A number identifying a logical control unit within an actual host. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.2 | OCTET STRING (SIZE(1)) | not-accessible | mandatory |
| esconStationPartitionNumber OBJECT-TYPE A number identifying a logical host within an actual host. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.3 | OCTET STRING (SIZE(1)) | not-accessible | mandatory |
| esconStationDeviceAddress OBJECT-TYPE A unique hexadecimal number allocated to each station on the same host link. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.4 | OCTET STRING (SIZE(1)) | not-accessible | mandatory |
| esconStationState OBJECT-TYPE The current state of the station. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.5 | INTEGER {idle(1), cpDefined(2), cpReset(3), cpActive(4), cpDelete(5), cpAbend(6), cldpWait(7), cldpDefinedl(8), cldpError(9), cldpLoad(10), cldpDump(11), deletePending(12), deleted(13), cpXidExpected(14)} | read-only | mandatory |
| esconStationAttentionDelay OBJECT-TYPE Specifies the amount of time in seconds that elapses from the receipt of a packet at an ESCON station (when no other packets are queued) before that station sends buffered data to the Host. An update to this object takes effect the next time the station establishes communications with the host. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.6 | INTEGER (0..420) | read-write | mandatory |
| esconStationAttentionTimeOut OBJECT-TYPE Specifies the amount of time in seconds that the station is to wait for a response to an attention signal it sent to the host before initiating channel disconnect. An update to this object takes effect the next time the station establishes communications with the host. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.7 | INTEGER (10..840) | read-write | mandatory |
| esconStationMaxBfru OBJECT-TYPE Number of buffers in the host buffer pool for receiving data from this station. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.8 | INTEGER (1..65535) | read-only | mandatory |
| esconStationUnitSize OBJECT-TYPE Maximum size of a buffer, in bytes, that the host can receive from this station. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.9 | INTEGER (64..4000) | read-only | mandatory |
| esconStationMaxMsgSizeReceived OBJECT-TYPE The maximum length of a message that can be received on this station. An update to this object takes effect the next time the station establishes communications with the host. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.10 | INTEGER (0..65535) | read-write | mandatory |
| esconStationMaxMsgSizeSent OBJECT-TYPE The maximum length of a message that can be sent from this station to the host. An update to this object takes effect the next time the station establishes communications with the host. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.11 | INTEGER (0..65535) | read-write | mandatory |
| esconStationDataPacketsOkReceived OBJECT-TYPE The number of data packets received from the host by this station without Data Check. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.12 | Counter32 | read-only | mandatory |
| esconStationDataPacketsKoReceived OBJECT-TYPE The number of data packets received from the host by this station with Data Check. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.13 | Counter32 | read-only | mandatory |
| esconStationDataPacketsSent OBJECT-TYPE The number of data packets sent to the host by this station. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.14 | Counter32 | read-only | mandatory |
| esconStationTotalFramesSent OBJECT-TYPE The number of data packets and control packets sent to the host by this station. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.15 | Counter32 | read-only | mandatory |
| esconStationDataPacketsRetransmitted OBJECT-TYPE The number of data packets retransmitted by this station | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.16 | Counter32 | read-only | mandatory |
| esconStationPositiveAckDataPackets OBJECT-TYPE The number of data packets sent by this station to the host that the host has positively acknowledged. When the host sends a positive acknowledgement for a group of n data packets, this counter is incremented by n. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.17 | Counter32 | read-only | mandatory |
| esconStationSecondChanceAttentions OBJECT-TYPE The number of times this station has sent a Second Chance Attention signal to the host. | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.18 | Counter32 | read-only | mandatory |
| esconStationCommandsRetried OBJECT-TYPE The number of times a command has been retried on this station | 1.3.6.1.4.1.2.6.119.4.14.3.1.1.19 | Counter32 | read-only | mandatory |
| esconConformance OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.119.4.14.4 |