MIBs Depot

IBM-TN3270E-MIB

Registered at
1.3.6.1.4.1.2.6.119.4.18.1
Namespace
ibm
Source file
IBM-TN3270E-MIB
Digest
sha256:bb27654e03a991e116835e6f961af981eb18cb7c2fd26cf162999db783be2953

Imports

FromSymbols
SNMPv2-CONFMODULE-COMPLIANCE, NOTIFICATION-GROUP
SNMPv2-SMIMODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, iso
SNMPv2-SMI-v1IpAddress
SNMPv2-TCDisplayString, TEXTUAL-CONVENTION
SNMPv2-TC-v1DisplayString

Imported by

Nothing in this corpus imports this module.

Load order

Every file a consumer needs in order to load this module, dependencies first.

IBM-TN3270E-MIB
SNMPv2-CONF
SNMPv2-SMI
SNMPv2-SMI-v1
SNMPv2-TC
SNMPv2-TC-v1

Objects

NameOIDSyntaxAccessStatus
ibmtn3270eMIB
OBJECT-IDENTITY
1.3.6.1.4.1.2.6.119.4.18.1
ibmtn3270eConnRejectTable
OBJECT-TYPE
A table of information about TN3270E connection rejections. This table does not contain information for connections that were successfully established, but terminated abnormally.
1.3.6.1.4.1.2.6.119.4.18.1.1not-accessiblemandatory
ibmtn3270eConnRejectEntry
OBJECT-TYPE
Information indicating why a particular client connection was rejected.
1.3.6.1.4.1.2.6.119.4.18.1.1.1not-accessiblemandatory
ibmtn3270eConnRejectIndex
OBJECT-TYPE
A unique identifier of a row in the connection rejection table.
1.3.6.1.4.1.2.6.119.4.18.1.1.1.1INTEGERnot-accessiblemandatory
ibmtn3270eConnRejectAddrType
OBJECT-TYPE
A indication of the type of client address provided in ibmtn3270eConnRejectClient.
1.3.6.1.4.1.2.6.119.4.18.1.1.1.2INTEGER {unknown(0), ipv4(1), ipv6(2)}read-onlymandatory
ibmtn3270eConnRejectClient
OBJECT-TYPE
The IP address of the client whose connection was rejected.
1.3.6.1.4.1.2.6.119.4.18.1.1.1.3OCTET STRING (SIZE(0..255))read-onlymandatory
ibmtn3270eConnRejectReason
OBJECT-TYPE
The reason the connection was rejected. Some of the values sound similar, but represent different failure points within the TN3270E server software. Also, some values are very specific to the TN3270E server software internals, so they may seem a bit cryptic to the user. noportinfo (1) // GetPortInfo failed to retrieve Port information cliunknown (2) // HostName filter failure - client_hostname unknown clinoauth (3) // Client is not authorized by FilterUser sockblock (4) // Could not make socket nonblocking nodeterm (5) // Node is terminating createfail (6) // TN3270Create failed to create session environment seqnum (7) // 0xFF seq number not doubled negfailed (8) // Negotiation failed notelquale (9) // Not TELQUALE_REQUEST termtypefail (10) // Verification of terminal type failed notypeprtgen (11) // TELQUALE_ASSOCIATE req but not TYPE_PRINTER_GENERIC clirplyfail (12) // Sending reply to client failed. valtelquale (13) // Validation of TELQUALE_REQUEST failed clisendfail (14) // Send to client failed failtelquale (15) // Verification of TELQUAL_IS failed termtypagain (16) // Received invalid terminal type for 2nd time noportagain (17) // GetPortInfo failed to retrieve Port information prtnoluname (18) // Associated printer req. with no LU name specified clinoauthent (19) // Client is not authorized by Filter entries clinoauthflt (20) // Client not authorized by Filter entries after retry noluconf (21) // REJECT_UNSUPP_REQ: No LUs configured. noportmore (22) // GetPortInfo failed to retrieve Port information noresource (23) // No resource spe+cified on Port & no name requested nameresource (24) // Resource specified on Port doesn't match name requested prtnoluagain (25) // Associated printer req. with no LU name specified noimplu (26) // No implicit LUs are available lunotfound (27) // Specified LU not found/available valluprt (28) // Validation of LU type failed for assoc. printer vallu (29) // Validation of LU type failed prtlunofind (30) // LU for associated printer not found nameinuse (31) // LU name requested currently in use reqlunofind (32) // LU requested not found valprtagain (33) // Validation of LU type failed for assoc. printer valluagain (34) // Validation of LU type failed luprtnofind (35) // LU for associated printer not found poolluinuse (36) // Requested pooled LU is already in use poollunofind (37) // Requested pooled LU is not found for assoc. printer restypnofind (38) // Requested type of resource is not found poolluconf (39) // Requested pooled LU is not found in config. list lucapreach (40) // LU capping value reached for this client address noappnmem (41) // APPN memory above the constrained threashold nomoreconn (42) // Max. number of TN3270 connection reached pooldep (43) // The pool from which the resource was requested has been depleted termnorsp (44) // The session was terminated before receiving a response from APPN
1.3.6.1.4.1.2.6.119.4.18.1.1.1.4INTEGER {noportinfo(1), cliunknown(2), clinoauth(3), sockblock(4), nodeterm(5), createfail(6), seqnum(7), negfailed(8), notelquale(9), termtypefail(10), notypeprtgen(11), clirplyfail(12), valtelquale(13), clisendfail(14), failtelquale(15), termtypagain(16), noportagain(17), prtnoluname(18), clinoauthent(19), clinoauthflt(20), noluconf(21), noportmore(22), noresource(23), nameresource(24), prtnoluagain(25), noimplu(26), lunotfound(27), valluprt(28), vallu(29), prtlunofind(30), nameinuse(31), reqlunofind(32), valprtagain(33), valluagain(34), luprtnofind(35), poolluinuse(36), poollunofind(37), restypnofind(38), poolluconf(39), lucapreach(40), noappnmem(41), nomoreconn(42), pooldep(43), termnorsp(44)}read-onlymandatory
ibmtn3270eConnRejectTime
OBJECT-TYPE
A string providing the date and time the connection was rejected.
1.3.6.1.4.1.2.6.119.4.18.1.1.1.5DisplayStringread-onlymandatory