IBM-Director-Alert-MIB
- Registered at
- 1.3.6.1.4.1.2.6.159
- Last updated
- 2004-04-21 00:00
- Organization
- IBM Corp.
- Revisions
- 2004-04-21 00:00, 2003-07-09 00:00
- Namespace
- ibm
- Source file
IBM-Director-Alert-MIB- Digest
sha256:bdc550912f7befd204b863da53600a19037ad514800e67191745c0be0580bc40
Description
This MIB is for use with the Event Action Plan Builder of IBM Director.
Contact
IBM Corporation
Imports
| From | Symbols |
|---|---|
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP |
| SNMPv2-SMI | Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises, iso |
| SNMPv2-TC | DisplayString, TEXTUAL-CONVENTION, TruthValue |
Imported by
Nothing in this corpus imports this module.
Load order
Every file a consumer needs in order to load this module, dependencies first.
IBM-Director-Alert-MIB SNMP-FRAMEWORK-MIB SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Objects
| Name | OID | Syntax | Access | Status |
|---|---|---|---|---|
| ibm OBJECT-IDENTITY | 1.3.6.1.4.1.2 | |||
| ibmProd OBJECT-IDENTITY | 1.3.6.1.4.1.2.6 | |||
| director OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159 | |||
| directorFamily OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.1 | |||
| topology OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.1.1 | |||
| directorAgent OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.1.2 | |||
| cpuMonitors OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.1.2.2 | |||
| diskMonitors OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.1.2.3 | |||
| memoryMonitors OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.1.2.4 | |||
| nicMonitors OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.1.2.5 | |||
| ntPerfMonitors OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.1.2.6 | |||
| tcpipMonitors OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.1.2.7 | |||
| monitorEventDetails OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.1.2.8 | |||
| actualValue OBJECT-TYPE The actual value of the monitor. | 1.3.6.1.4.1.2.6.159.201.1.2.8.1 | SnmpAdminString | read-only | current |
| duration OBJECT-TYPE The duration of this monitor. | 1.3.6.1.4.1.2.6.159.201.1.2.8.2 | DisplayString | read-only | current |
| monitorResource OBJECT-TYPE The monitor resource. | 1.3.6.1.4.1.2.6.159.201.1.2.8.3 | SnmpAdminString | read-only | current |
| thresholdName OBJECT-TYPE The name of the monitor threshold. | 1.3.6.1.4.1.2.6.159.201.1.2.8.4 | SnmpAdminString | read-only | current |
| thresholdValue OBJECT-TYPE The value of the monitor threshold. | 1.3.6.1.4.1.2.6.159.201.1.2.8.5 | SnmpAdminString | read-only | current |
| test OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.1.3 | |||
| console OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.1.4 | |||
| consoleEventDetails OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.1.4.1 | |||
| userID OBJECT-TYPE The console user ID. | 1.3.6.1.4.1.2.6.159.201.1.4.1.1 | SnmpAdminString | read-only | current |
| address OBJECT-TYPE The console address. | 1.3.6.1.4.1.2.6.159.201.1.4.1.2 | SnmpAdminString | read-only | current |
| userName OBJECT-TYPE The console username. | 1.3.6.1.4.1.2.6.159.201.1.4.1.3 | SnmpAdminString | read-only | current |
| userDescription OBJECT-TYPE The console username's description. | 1.3.6.1.4.1.2.6.159.201.1.4.1.4 | SnmpAdminString | read-only | current |
| userLocale OBJECT-TYPE The console user's locale. | 1.3.6.1.4.1.2.6.159.201.1.4.1.5 | SnmpAdminString | read-only | current |
| logonFailure OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.1.4.2 | |||
| cimFamily OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.3 | |||
| windowsNTEventLog OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.3.1 | |||
| windowsNTEventLogEventDetails OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.3.1.1 | |||
| category OBJECT-TYPE The Windows Event Log category. | 1.3.6.1.4.1.2.6.159.201.3.1.1.1 | Integer32 | read-only | current |
| categoryString OBJECT-TYPE The Windows Event Log category string. | 1.3.6.1.4.1.2.6.159.201.3.1.1.2 | SnmpAdminString | read-only | current |
| computerName OBJECT-TYPE The computer name of the Windows Event Log event. | 1.3.6.1.4.1.2.6.159.201.3.1.1.3 | SnmpAdminString | read-only | current |
| data OBJECT-TYPE The Windows Event Log data for the event. | 1.3.6.1.4.1.2.6.159.201.3.1.1.4 | OCTET STRING | read-only | current |
| eventLogCode OBJECT-TYPE The Windows Event Log numeric event ID. | 1.3.6.1.4.1.2.6.159.201.3.1.1.5 | Integer32 | read-only | current |
| eventLogIdentifier OBJECT-TYPE The Windows Event Log numeric event identifier. | 1.3.6.1.4.1.2.6.159.201.3.1.1.6 | DisplayString | read-only | current |
| eventLogType OBJECT-TYPE The Windows Event Log numeric event type. | 1.3.6.1.4.1.2.6.159.201.3.1.1.7 | Integer32 | read-only | current |
| insertionStrings OBJECT-TYPE The Windows Event Log insertion strings. | 1.3.6.1.4.1.2.6.159.201.3.1.1.8 | SnmpAdminString | read-only | current |
| logFile OBJECT-TYPE The Windows Event Log file name. | 1.3.6.1.4.1.2.6.159.201.3.1.1.9 | SnmpAdminString | read-only | current |
| message OBJECT-TYPE The Windows Event Log message string. | 1.3.6.1.4.1.2.6.159.201.3.1.1.10 | SnmpAdminString | read-only | current |
| recordNumber OBJECT-TYPE The Windows Event Log record number. | 1.3.6.1.4.1.2.6.159.201.3.1.1.11 | DisplayString | read-only | current |
| sourceName OBJECT-TYPE The Windows Event Log source name. | 1.3.6.1.4.1.2.6.159.201.3.1.1.12 | SnmpAdminString | read-only | current |
| type OBJECT-TYPE The Windows Event Log type. | 1.3.6.1.4.1.2.6.159.201.3.1.1.13 | SnmpAdminString | read-only | current |
| user OBJECT-TYPE The Windows Event Log user. | 1.3.6.1.4.1.2.6.159.201.3.1.1.14 | SnmpAdminString | read-only | current |
| windowsNTService OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.3.2 | |||
| windowsNTServiceEventDetails OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.3.2.1 | |||
| acceptPause OBJECT-TYPE Whether this service accepts the pause state change. | 1.3.6.1.4.1.2.6.159.201.3.2.1.1 | TruthValue | read-only | current |
| acceptStop OBJECT-TYPE Whether this service accepts the stop state change. | 1.3.6.1.4.1.2.6.159.201.3.2.1.2 | TruthValue | read-only | current |
| caption OBJECT-TYPE The caption string for this service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.3 | SnmpAdminString | read-only | current |
| checkPoint OBJECT-TYPE The service's check point. | 1.3.6.1.4.1.2.6.159.201.3.2.1.4 | DisplayString | read-only | current |
| creationClassName OBJECT-TYPE The creation class name for the service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.5 | SnmpAdminString | read-only | current |
| serviceDescription OBJECT-TYPE The description of the service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.6 | SnmpAdminString | read-only | current |
| desktopInteract OBJECT-TYPE Whether the service interacts with the desktop. | 1.3.6.1.4.1.2.6.159.201.3.2.1.7 | TruthValue | read-only | current |
| displayName OBJECT-TYPE The displayable name for the service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.8 | SnmpAdminString | read-only | current |
| errorControl OBJECT-TYPE The error control value for the service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.9 | SnmpAdminString | read-only | current |
| exitCode OBJECT-TYPE The exit code of the process for the service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.10 | DisplayString | read-only | current |
| name OBJECT-TYPE The name of the service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.11 | SnmpAdminString | read-only | current |
| pathName OBJECT-TYPE The path name for the service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.12 | SnmpAdminString | read-only | current |
| processId OBJECT-TYPE The process ID of the running service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.13 | DisplayString | read-only | current |
| serviceSpecificExitCode OBJECT-TYPE The specific exit code for the service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.14 | DisplayString | read-only | current |
| serviceType OBJECT-TYPE The type of service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.15 | SnmpAdminString | read-only | current |
| startMode OBJECT-TYPE The start mode for the service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.16 | SnmpAdminString | read-only | current |
| startName OBJECT-TYPE The start name for the service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.17 | SnmpAdminString | read-only | current |
| started OBJECT-TYPE Whether this service has started. | 1.3.6.1.4.1.2.6.159.201.3.2.1.18 | TruthValue | read-only | current |
| serviceState OBJECT-TYPE The state of the service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.19 | SnmpAdminString | read-only | current |
| status OBJECT-TYPE The status of the service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.20 | SnmpAdminString | read-only | current |
| systemCreationClassName OBJECT-TYPE The system creation class name for the service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.21 | SnmpAdminString | read-only | current |
| systemName OBJECT-TYPE The system name for the service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.22 | SnmpAdminString | read-only | current |
| tagId OBJECT-TYPE The tag ID of the service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.23 | DisplayString | read-only | current |
| waitHint OBJECT-TYPE The value of the wait hint for the service. | 1.3.6.1.4.1.2.6.159.201.3.2.1.24 | DisplayString | read-only | current |
| windowsRegistry OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.3.3 | |||
| windowsRegistryEventDetails OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.3.3.1 | |||
| hive OBJECT-TYPE The Windows Registry hive for this event. | 1.3.6.1.4.1.2.6.159.201.3.3.1.1 | SnmpAdminString | read-only | current |
| rootPath OBJECT-TYPE The Windows Registry root path for this event. | 1.3.6.1.4.1.2.6.159.201.3.3.1.2 | SnmpAdminString | read-only | current |
| securityDescriptor OBJECT-TYPE The Windows Registry security descriptor for this event. | 1.3.6.1.4.1.2.6.159.201.3.3.1.3 | OCTET STRING | read-only | current |
| timeCreated OBJECT-TYPE The time this item was created in the Windows Registry. | 1.3.6.1.4.1.2.6.159.201.3.3.1.4 | SnmpAdminString | read-only | current |
| mpaFamily OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4 | |||
| mpaEventDetails OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.1 | |||
| alertCode OBJECT-TYPE The alert code. | 1.3.6.1.4.1.2.6.159.201.4.1.1 | Integer32 | read-only | current |
| busId OBJECT-TYPE The bus ID. | 1.3.6.1.4.1.2.6.159.201.4.1.2 | Integer32 | read-only | current |
| componentId OBJECT-TYPE The component ID. | 1.3.6.1.4.1.2.6.159.201.4.1.3 | SnmpAdminString | read-only | current |
| firmwareCode OBJECT-TYPE The firmware identification code. | 1.3.6.1.4.1.2.6.159.201.4.1.4 | OCTET STRING | read-only | current |
| ipAddress1 OBJECT-TYPE The first IP address. | 1.3.6.1.4.1.2.6.159.201.4.1.5 | OCTET STRING | read-only | current |
| ipAddress2 OBJECT-TYPE The second IP address. | 1.3.6.1.4.1.2.6.159.201.4.1.6 | OCTET STRING | read-only | current |
| issue OBJECT-TYPE The issue for the event. | 1.3.6.1.4.1.2.6.159.201.4.1.7 | SnmpAdminString | read-only | current |
| powerDomain OBJECT-TYPE The domain of the power supply. | 1.3.6.1.4.1.2.6.159.201.4.1.8 | Integer32 | read-only | current |
| reason OBJECT-TYPE The reason for the event. | 1.3.6.1.4.1.2.6.159.201.4.1.9 | SnmpAdminString | read-only | current |
| scsiId OBJECT-TYPE The ID of the SCSI device. | 1.3.6.1.4.1.2.6.159.201.4.1.10 | Integer32 | read-only | current |
| side OBJECT-TYPE The side in which the event occured. | 1.3.6.1.4.1.2.6.159.201.4.1.11 | SnmpAdminString | read-only | current |
| newState OBJECT-TYPE The new state. | 1.3.6.1.4.1.2.6.159.201.4.1.12 | SnmpAdminString | read-only | current |
| temperatureSensor OBJECT-TYPE The current temperature. | 1.3.6.1.4.1.2.6.159.201.4.1.13 | SnmpAdminString | read-only | current |
| threshold OBJECT-TYPE The threshold for the event. | 1.3.6.1.4.1.2.6.159.201.4.1.14 | SnmpAdminString | read-only | current |
| universalUniqueId OBJECT-TYPE The universal unique ID. | 1.3.6.1.4.1.2.6.159.201.4.1.15 | OCTET STRING | read-only | current |
| senderUniversalUniqueId OBJECT-TYPE The universal unique ID of the sender. | 1.3.6.1.4.1.2.6.159.201.4.1.16 | OCTET STRING | read-only | current |
| sourceUniversalUniqueId OBJECT-TYPE The universal unique ID of the source. | 1.3.6.1.4.1.2.6.159.201.4.1.17 | OCTET STRING | read-only | current |
| unitNumber OBJECT-TYPE The unit number. | 1.3.6.1.4.1.2.6.159.201.4.1.18 | Integer32 | read-only | current |
| voltageSensor OBJECT-TYPE The voltage sensor. | 1.3.6.1.4.1.2.6.159.201.4.1.19 | SnmpAdminString | read-only | current |
| component OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2 | |||
| bladeServer OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.1 | |||
| coD OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.1.1 | |||
| bus OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.2 | |||
| chassis OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.3 | |||
| dasd OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.4 | |||
| memory OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.5 | |||
| componentFan OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.6 | |||
| hardwareInformation OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.7 | |||
| hardwareCrashDump OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.7.1 | |||
| ioModule OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.8 | |||
| ioModulePower OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.8.5 | |||
| kvm OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.9 | |||
| osImage OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.10 | |||
| osImageCrashDump OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.10.1 | |||
| powerSubsystem OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.12 | |||
| powerSupply OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.13 | |||
| server OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.14 | |||
| serverPower OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.14.1 | |||
| serviceProcessor OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.15 | |||
| smpExpansionModule OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.16 | |||
| usb OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.17 | |||
| vrm OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.2.18 | |||
| critical OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.3 | |||
| powerFailure OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.3.3 | |||
| criticalTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.3.5 | |||
| criticalVoltage OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.3.6 | |||
| criticalTwelveVolts OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.3.6.1 | |||
| criticalOneVolt OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.3.6.6 | |||
| criticalTwoVolts OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.3.6.7 | |||
| criticalThreeVolts OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.3.6.8 | |||
| criticalThreeVoltsPci OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.3.6.9 | |||
| criticalThreeVoltsStandby OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.3.6.10 | |||
| criticalFiveVolts OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.3.6.11 | |||
| criticalFiveVoltsFault OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.3.6.12 | |||
| criticalFiveVoltsPci OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.3.6.13 | |||
| criticalFiveVoltsStandby OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.3.6.14 | |||
| criticalNTwelveVolts OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.3.6.15 | |||
| deployment OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.4 | |||
| environmental OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.5 | |||
| nonCritical OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.6 | |||
| nonCriticalFan OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.6.1 | |||
| nonCriticalTemperature OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.6.4 | |||
| nonCriticalVoltage OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.6.5 | |||
| nonCriticalTwelveVolts OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.6.5.1 | |||
| nonCriticalOneVolt OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.6.5.2 | |||
| nonCriticalTwoVolts OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.6.5.3 | |||
| nonCriticalThreeVolts OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.6.5.4 | |||
| nonCriticalThreeVoltsPci OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.6.5.5 | |||
| nonCriticalThreeVoltsStandby OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.6.5.6 | |||
| nonCriticalFiveVolts OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.6.5.7 | |||
| nonCriticalFiveVoltsPci OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.6.5.8 | |||
| nonCriticalFiveVoltsStandby OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.6.5.9 | |||
| nonCriticalNTwelveVolts OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.6.5.10 | |||
| platform OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.7 | |||
| scalableNode OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.7.1 | |||
| scalableNodeMode OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.7.1.1 | |||
| scalableNodeStandalone OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.7.1.2 | |||
| standaloneMode OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1 | |||
| reset OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.2 | |||
| scalablePartition OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.7.2 | |||
| scalablePartitionState OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.7.2.2 | |||
| system OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.8 | |||
| fuelGauge OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.8.2 | |||
| systemPfa OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.4.8.5 | |||
| petFamily OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.5 | |||
| petFamilyEventDetails OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.5.1 | |||
| allVariableBindings OBJECT-TYPE All of the variable bindings for this PET trap. | 1.3.6.1.4.1.2.6.159.201.5.1.1 | OCTET STRING | read-only | current |
| entity OBJECT-TYPE The entity of this PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.2 | OCTET STRING | read-only | current |
| entityInstance OBJECT-TYPE The entity instance of this PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.3 | OCTET STRING | read-only | current |
| petEventData OBJECT-TYPE The event data of this PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.4 | OCTET STRING | read-only | current |
| petEventSeverity OBJECT-TYPE The severity of this PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.5 | OCTET STRING | read-only | current |
| petEventSourceType OBJECT-TYPE The source type of this PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.6 | OCTET STRING | read-only | current |
| petEventType OBJECT-TYPE The type of the PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.7 | OCTET STRING | read-only | current |
| guid OBJECT-TYPE The GUID for this PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.8 | OCTET STRING | read-only | current |
| languageCode OBJECT-TYPE The language code for this PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.9 | OCTET STRING | read-only | current |
| localTimeStamp OBJECT-TYPE The local time stamp of this PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.10 | DisplayString | read-only | current |
| manufacturerId OBJECT-TYPE The manufacturer ID for the source of the PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.11 | DisplayString | read-only | current |
| oemCustomField OBJECT-TYPE The value for the OEM customer field of this PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.12 | OCTET STRING | read-only | current |
| offset OBJECT-TYPE The offset for this PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.13 | OCTET STRING | read-only | current |
| sensorDevice OBJECT-TYPE The sensor device for this PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.14 | OCTET STRING | read-only | current |
| sensorNumber OBJECT-TYPE The sensor number for this PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.15 | OCTET STRING | read-only | current |
| sensorType OBJECT-TYPE The sensor type for this PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.16 | OCTET STRING | read-only | current |
| sequenceId OBJECT-TYPE The sequence ID for this PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.17 | Integer32 | read-only | current |
| systemId OBJECT-TYPE The system ID for this PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.18 | Integer32 | read-only | current |
| trapSourceType OBJECT-TYPE The trap source type for this PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.19 | OCTET STRING | read-only | current |
| utcOffset OBJECT-TYPE The UTC offset for this PET event. | 1.3.6.1.4.1.2.6.159.201.5.1.20 | Integer32 | read-only | current |
| petEnvironmental OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.5.2 | |||
| petEnvironmentalSensor OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.5.2.1 | |||
| firmware OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.5.3 | |||
| bios OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.5.3.1 | |||
| hardware OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.5.4 | |||
| petFamilySystem OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.5.5 | |||
| petFamilySystemOs OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.5.5.1 | |||
| petFamilySystemOsOperation OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.5.5.1.2 | |||
| storageFamily OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.6 | |||
| serveRaidController OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.6.1 | |||
| physicalDrive OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.6.1.1 | |||
| state OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.6.1.2 | |||
| directorTrapsConformance OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.100 | |||
| directorTrapsGroups OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.100.1 | |||
| directorTrapsCompliances OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.201.100.2 | |||
| description OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.202 | |||
| trapType OBJECT-TYPE The type of the event. | 1.3.6.1.4.1.2.6.159.202.1 | SnmpAdminString | read-only | current |
| trapSeverity OBJECT-TYPE The severity of the event. | 1.3.6.1.4.1.2.6.159.202.2 | SnmpAdminString | read-only | current |
| trapSenderName OBJECT-TYPE The system name from which the event was sent. | 1.3.6.1.4.1.2.6.159.202.3 | SnmpAdminString | read-only | current |
| trapManagedObjectName OBJECT-TYPE The system name for which the event was generated. | 1.3.6.1.4.1.2.6.159.202.4 | SnmpAdminString | read-only | current |
| trapText OBJECT-TYPE Text associated with the event. | 1.3.6.1.4.1.2.6.159.202.5 | SnmpAdminString | read-only | current |
| trapCategory OBJECT-TYPE The category of the event. | 1.3.6.1.4.1.2.6.159.202.6 | SnmpAdminString | read-only | current |
| details OBJECT-IDENTITY | 1.3.6.1.4.1.2.6.159.9696 | |||
| char OBJECT-TYPE Eight bit unsigned event detail. | 1.3.6.1.4.1.2.6.159.9696.1 | OCTET STRING | read-only | current |
| short OBJECT-TYPE Sixteen bit signed event detail. | 1.3.6.1.4.1.2.6.159.9696.2 | Integer32 | read-only | current |
| int OBJECT-TYPE Thirty-two bit signed event detail. | 1.3.6.1.4.1.2.6.159.9696.3 | Integer32 | read-only | current |
| long OBJECT-TYPE Sixty-four bit signed event detail. | 1.3.6.1.4.1.2.6.159.9696.4 | DisplayString | read-only | current |
| boolean OBJECT-TYPE Thirty-two bit unsigned event detail. | 1.3.6.1.4.1.2.6.159.9696.5 | TruthValue | read-only | current |
| float OBJECT-TYPE Thirty-two bit decimal pointed event detail. | 1.3.6.1.4.1.2.6.159.9696.6 | DisplayString | read-only | current |
| double OBJECT-TYPE Sixty-four bit decimal pointed event detail. | 1.3.6.1.4.1.2.6.159.9696.7 | DisplayString | read-only | current |
| octet OBJECT-TYPE A string of bytes holding an event detail. | 1.3.6.1.4.1.2.6.159.9696.8 | DisplayString | read-only | current |
| string OBJECT-TYPE A string of unicode chars (normal text) holding an event detail. | 1.3.6.1.4.1.2.6.159.9696.9 | SnmpAdminString | read-only | current |
| dateTime OBJECT-TYPE Date and time since 1/1970 as an event detail. | 1.3.6.1.4.1.2.6.159.9696.10 | DisplayString | read-only | current |
| uniChar OBJECT-TYPE A unicode char holding an event detail. | 1.3.6.1.4.1.2.6.159.9696.11 | DisplayString | read-only | current |
| byte OBJECT-TYPE One byte holding an event detail. | 1.3.6.1.4.1.2.6.159.9696.12 | DisplayString | read-only | current |
Notifications
| Name | OID | Status |
|---|---|---|
| online NOTIFICATION-TYPE The managed object's state has changed to online. | 1.3.6.1.4.1.2.6.159.201.1.1.1 | current |
| offline NOTIFICATION-TYPE The managed object's state has changed to offline. | 1.3.6.1.4.1.2.6.159.201.1.1.2 | current |
| create NOTIFICATION-TYPE The managed object has been created. | 1.3.6.1.4.1.2.6.159.201.1.1.3 | current |
| change NOTIFICATION-TYPE The managed object has changed. | 1.3.6.1.4.1.2.6.159.201.1.1.4 | current |
| destroy NOTIFICATION-TYPE The managed object has been destroyed. | 1.3.6.1.4.1.2.6.159.201.1.1.5 | current |
| processMonitor NOTIFICATION-TYPE The process monitor threshold has generated an event. | 1.3.6.1.4.1.2.6.159.201.1.2.1 | current |
| cpuUtilization NOTIFICATION-TYPE The CPU utilization monitor threshold has generated an event. | 1.3.6.1.4.1.2.6.159.201.1.2.2.1 | current |
| processCount NOTIFICATION-TYPE The process count monitor threshold has generated an event. | 1.3.6.1.4.1.2.6.159.201.1.2.2.2 | current |
| driveSpaceUsed NOTIFICATION-TYPE The drive space used monitor threshold has generated an event. | 1.3.6.1.4.1.2.6.159.201.1.2.3.1 | current |
| driveSpaceUsedPercent NOTIFICATION-TYPE The percentage of drive space used monitor threshold has generated an event. | 1.3.6.1.4.1.2.6.159.201.1.2.3.2 | current |
| driveSpaceRemaining NOTIFICATION-TYPE The drive space remaining monitor threshold has generated an event. | 1.3.6.1.4.1.2.6.159.201.1.2.3.3 | current |
| driveWorkload NOTIFICATION-TYPE The drive workload monitor threshold has generated an event. | 1.3.6.1.4.1.2.6.159.201.1.2.3.4 | current |
| lockedMemory NOTIFICATION-TYPE The locked memory monitor threshold has generated an event. | 1.3.6.1.4.1.2.6.159.201.1.2.4.1 | current |
| memoryUsage NOTIFICATION-TYPE The memory usage monitor threshold has generated an event. | 1.3.6.1.4.1.2.6.159.201.1.2.4.2 | current |
| totalPrivilegedTimePercent NOTIFICATION-TYPE The percentage of total privileged time monitor threshold has generated an event. | 1.3.6.1.4.1.2.6.159.201.1.2.6.1 | current |
| fileReadOperationsPerSec NOTIFICATION-TYPE The files read per second monitor threshold has generated an event. | 1.3.6.1.4.1.2.6.159.201.1.2.6.2 | current |
| udpPacketsSentPerSec NOTIFICATION-TYPE A threshold event for the number of UDP packets sent per second. | 1.3.6.1.4.1.2.6.159.201.1.2.7.1 | current |
| udpPacketsReceivedPerSec NOTIFICATION-TYPE A threshold event for the number of UDP packets received per second. | 1.3.6.1.4.1.2.6.159.201.1.2.7.2 | current |
| ipPacketsSentPerSec NOTIFICATION-TYPE A threshold event for the number of IP packets sent per second. | 1.3.6.1.4.1.2.6.159.201.1.2.7.3 | current |
| ipPacketsReceivedPerSec NOTIFICATION-TYPE A threshold event for the number of IP packets received per second. | 1.3.6.1.4.1.2.6.159.201.1.2.7.4 | current |
| ipErrorPacketsReceivedPerSec NOTIFICATION-TYPE A threshold event for the number of IP packets received with errors per second. | 1.3.6.1.4.1.2.6.159.201.1.2.7.5 | current |
| tcpConnections NOTIFICATION-TYPE A threshold event for the number of TCP connections. | 1.3.6.1.4.1.2.6.159.201.1.2.7.6 | current |
| action NOTIFICATION-TYPE The test action event. An internally generated event for the purpose of testing the action configuration. | 1.3.6.1.4.1.2.6.159.201.1.3.1 | current |
| badPassword NOTIFICATION-TYPE When attempting to logon to the console, a bad password was used. | 1.3.6.1.4.1.2.6.159.201.1.4.2.1 | current |
| badUserID NOTIFICATION-TYPE When attempting to logon to the console, a bad user ID was used. | 1.3.6.1.4.1.2.6.159.201.1.4.2.2 | current |
| disabledUserID NOTIFICATION-TYPE When attempting to logon to the console, a disabled user ID was used. | 1.3.6.1.4.1.2.6.159.201.1.4.2.3 | current |
| downlevelConsole NOTIFICATION-TYPE When attempting to logon to the console, a downlevel console was used. | 1.3.6.1.4.1.2.6.159.201.1.4.2.4 | current |
| expiredPassword NOTIFICATION-TYPE When attempting to logon to the console, an expired password was used. | 1.3.6.1.4.1.2.6.159.201.1.4.2.5 | current |
| tooManyActiveIDs NOTIFICATION-TYPE When attempting to logon to the console, too many IDs were active. | 1.3.6.1.4.1.2.6.159.201.1.4.2.6 | current |
| tooManyActiveLogons NOTIFICATION-TYPE When attempting to logon to the console, too many logons were active. | 1.3.6.1.4.1.2.6.159.201.1.4.2.7 | current |
| uplevelConsole NOTIFICATION-TYPE When attempting to logon to the console, an uplevel console was used. | 1.3.6.1.4.1.2.6.159.201.1.4.2.8 | current |
| logoff NOTIFICATION-TYPE A user has logged off the console. | 1.3.6.1.4.1.2.6.159.201.1.4.3 | current |
| logon NOTIFICATION-TYPE A user has logged on the console. | 1.3.6.1.4.1.2.6.159.201.1.4.4 | current |
| generalEvent NOTIFICATION-TYPE This is a IBM Director event converted into an SNMP trap. This trap is only used for events with no mapping. | 1.3.6.1.4.1.2.6.159.201.2 | current |
| applicationLog NOTIFICATION-TYPE The Windows NT application event log has changed. | 1.3.6.1.4.1.2.6.159.201.3.1.2 | current |
| securityLog NOTIFICATION-TYPE The Windows NT application security log has changed. | 1.3.6.1.4.1.2.6.159.201.3.1.3 | current |
| systemLog NOTIFICATION-TYPE The Windows NT application system log has changed. | 1.3.6.1.4.1.2.6.159.201.3.1.4 | current |
| startedService NOTIFICATION-TYPE A Windows NT service has started. | 1.3.6.1.4.1.2.6.159.201.3.2.2 | current |
| stoppedService NOTIFICATION-TYPE A Windows NT service has stopped. | 1.3.6.1.4.1.2.6.159.201.3.2.3 | current |
| softwareTreeChanged NOTIFICATION-TYPE The Windows software tree section of the registry has changed. | 1.3.6.1.4.1.2.6.159.201.3.3.2 | current |
| systemTreeChanged NOTIFICATION-TYPE The Windows system tree section of the registry has changed. | 1.3.6.1.4.1.2.6.159.201.3.3.3 | current |
| codEnabled NOTIFICATION-TYPE The CoD has been enabled. | 1.3.6.1.4.1.2.6.159.201.4.2.1.1.1 | current |
| bladeServerCommunication NOTIFICATION-TYPE Communication with a blade has been established. | 1.3.6.1.4.1.2.6.159.201.4.2.1.2 | current |
| bladeServerInserted NOTIFICATION-TYPE A blade has been inserted. | 1.3.6.1.4.1.2.6.159.201.4.2.1.3 | current |
| bladeServerRemoved NOTIFICATION-TYPE A blade has been removed. | 1.3.6.1.4.1.2.6.159.201.4.2.1.4 | current |
| busCommunication NOTIFICATION-TYPE Communication with a bus has been established. | 1.3.6.1.4.1.2.6.159.201.4.2.2.1 | current |
| chassisConfiguration NOTIFICATION-TYPE The blade chassis configuration has changed. | 1.3.6.1.4.1.2.6.159.201.4.2.3.1 | current |
| chassisFailed NOTIFICATION-TYPE The blade chassis has failed. | 1.3.6.1.4.1.2.6.159.201.4.2.3.2 | current |
| dasdFailed NOTIFICATION-TYPE a direct access storage device has failed. | 1.3.6.1.4.1.2.6.159.201.4.2.4.1 | current |
| dasdInserted NOTIFICATION-TYPE A direct access storage device has been inserted. | 1.3.6.1.4.1.2.6.159.201.4.2.4.2 | current |
| dasdRemoved NOTIFICATION-TYPE A direct access storage device has been removed. | 1.3.6.1.4.1.2.6.159.201.4.2.4.3 | current |
| memoryFailed NOTIFICATION-TYPE Some memory has failed. | 1.3.6.1.4.1.2.6.159.201.4.2.5.1 | current |
| componentFanFailed NOTIFICATION-TYPE A fan has failed. | 1.3.6.1.4.1.2.6.159.201.4.2.6.1 | current |
| componentFanInserted NOTIFICATION-TYPE A fan has been inserted. | 1.3.6.1.4.1.2.6.159.201.4.2.6.2 | current |
| componentFanPfa NOTIFICATION-TYPE The fan component has generated a PFA. | 1.3.6.1.4.1.2.6.159.201.4.2.6.3 | current |
| componentFanRemoved NOTIFICATION-TYPE A fan has been removed. | 1.3.6.1.4.1.2.6.159.201.4.2.6.4 | current |
| hardwareCrashDumpAborted NOTIFICATION-TYPE A hardware crash dump was aborted. | 1.3.6.1.4.1.2.6.159.201.4.2.7.1.1 | current |
| hardwareCrashDumpCompleted NOTIFICATION-TYPE A hardware crash dump has completed. | 1.3.6.1.4.1.2.6.159.201.4.2.7.1.2 | current |
| hardwareCrashDumpInitiated NOTIFICATION-TYPE A hardware crash dump has been initiated. | 1.3.6.1.4.1.2.6.159.201.4.2.7.1.3 | current |
| ioModuleConfiguration NOTIFICATION-TYPE An I/O module's configuration has changed. | 1.3.6.1.4.1.2.6.159.201.4.2.8.1 | current |
| ioModuleFailed NOTIFICATION-TYPE An I/O module has failed. | 1.3.6.1.4.1.2.6.159.201.4.2.8.2 | current |
| ioModuleInserted NOTIFICATION-TYPE An I/O module has been inserted. | 1.3.6.1.4.1.2.6.159.201.4.2.8.3 | current |
| ioModulePost NOTIFICATION-TYPE An I/O module has past POST. | 1.3.6.1.4.1.2.6.159.201.4.2.8.4 | current |
| ioModulePowerOn NOTIFICATION-TYPE An I/O module has been powered on. | 1.3.6.1.4.1.2.6.159.201.4.2.8.5.1 | current |
| ioModulePowerOff NOTIFICATION-TYPE An I/O module has been powered off. | 1.3.6.1.4.1.2.6.159.201.4.2.8.5.2 | current |
| ioModuleRedundancy NOTIFICATION-TYPE An I/O module is a redundancy. | 1.3.6.1.4.1.2.6.159.201.4.2.8.6 | current |
| ioModuleRemoved NOTIFICATION-TYPE An I/O module has been removed. | 1.3.6.1.4.1.2.6.159.201.4.2.8.7 | current |
| kvmOwner NOTIFICATION-TYPE The KVM owner has changed. | 1.3.6.1.4.1.2.6.159.201.4.2.9.1 | current |
| osImageCrashDumpAborted NOTIFICATION-TYPE The operating system image crash dump was aborted. | 1.3.6.1.4.1.2.6.159.201.4.2.10.1.1 | current |
| osImageCrashDumpCompleted NOTIFICATION-TYPE The operating system image crash dump has completed. | 1.3.6.1.4.1.2.6.159.201.4.2.10.1.2 | current |
| osImageCrashDumpInitiated NOTIFICATION-TYPE The operating system image crash dump has been initiated. | 1.3.6.1.4.1.2.6.159.201.4.2.10.1.3 | current |
| componentPfa NOTIFICATION-TYPE A component has generated a PFA. | 1.3.6.1.4.1.2.6.159.201.4.2.11 | current |
| powerSubsystemLowFuel NOTIFICATION-TYPE The power subsystem indicates low fuel. | 1.3.6.1.4.1.2.6.159.201.4.2.12.1 | current |
| powerSubsystemOverCurrent NOTIFICATION-TYPE The power subsystem indicates over current. | 1.3.6.1.4.1.2.6.159.201.4.2.12.2 | current |
| powerSubsystemOverPower NOTIFICATION-TYPE The power subsystem indicates over power. | 1.3.6.1.4.1.2.6.159.201.4.2.12.3 | current |
| powerSubsystemRedundancy NOTIFICATION-TYPE The power subsystem indicates a redundancy. | 1.3.6.1.4.1.2.6.159.201.4.2.12.4 | current |
| powerSupplyFailed NOTIFICATION-TYPE A power supply has failed. | 1.3.6.1.4.1.2.6.159.201.4.2.13.1 | current |
| powerSupplyInserted NOTIFICATION-TYPE A power supply has been inserted. | 1.3.6.1.4.1.2.6.159.201.4.2.13.2 | current |
| powerSupplyRemoved NOTIFICATION-TYPE A power supply has been removed. | 1.3.6.1.4.1.2.6.159.201.4.2.13.3 | current |
| serverPowerOff NOTIFICATION-TYPE The server has powered off. | 1.3.6.1.4.1.2.6.159.201.4.2.14.1.1 | current |
| serverPowerOn NOTIFICATION-TYPE The server has powered on. | 1.3.6.1.4.1.2.6.159.201.4.2.14.1.2 | current |
| serverPowerState NOTIFICATION-TYPE The server's power state has changed. | 1.3.6.1.4.1.2.6.159.201.4.2.14.2 | current |
| serviceProcessorActive NOTIFICATION-TYPE A service processor is now active. | 1.3.6.1.4.1.2.6.159.201.4.2.15.1 | current |
| serviceProcessorConfiguration NOTIFICATION-TYPE A service processor configuration has changed. | 1.3.6.1.4.1.2.6.159.201.4.2.15.2 | current |
| serviceProcessorInserted NOTIFICATION-TYPE A service processor has been inserted. | 1.3.6.1.4.1.2.6.159.201.4.2.15.3 | current |
| serviceProcessorLog NOTIFICATION-TYPE A service processor has generated a log. | 1.3.6.1.4.1.2.6.159.201.4.2.15.4 | current |
| serviceProcessorNetworkStack NOTIFICATION-TYPE A service processor network stack has changed. | 1.3.6.1.4.1.2.6.159.201.4.2.15.5 | current |
| serviceProcessorRedundancy NOTIFICATION-TYPE A service processor detected a redundancy. | 1.3.6.1.4.1.2.6.159.201.4.2.15.6 | current |
| serviceProcessorRemoteLogin NOTIFICATION-TYPE A remove login was made into the service processor. | 1.3.6.1.4.1.2.6.159.201.4.2.15.7 | current |
| serviceProcessorRemoved NOTIFICATION-TYPE A service processor has been removed. | 1.3.6.1.4.1.2.6.159.201.4.2.15.8 | current |
| serviceProcessorRestart NOTIFICATION-TYPE A service processor has been restarted. | 1.3.6.1.4.1.2.6.159.201.4.2.15.9 | current |
| serviceProcessorTest NOTIFICATION-TYPE A service processor test was issued. | 1.3.6.1.4.1.2.6.159.201.4.2.15.10 | current |
| smpExpansionModuleDisabled NOTIFICATION-TYPE An SMP expansion module has been disabled. | 1.3.6.1.4.1.2.6.159.201.4.2.16.1 | current |
| usbInserted NOTIFICATION-TYPE A USB device has been inserted. | 1.3.6.1.4.1.2.6.159.201.4.2.17.1 | current |
| usbOwner NOTIFICATION-TYPE A USB device owner has changed. | 1.3.6.1.4.1.2.6.159.201.4.2.17.2 | current |
| usbRemoved NOTIFICATION-TYPE A USB device has been removed. | 1.3.6.1.4.1.2.6.159.201.4.2.17.3 | current |
| vrmFailed NOTIFICATION-TYPE The VRM has failed. | 1.3.6.1.4.1.2.6.159.201.4.2.18.1 | current |
| hardDiskDrive NOTIFICATION-TYPE A hard disk drive is in critical state. | 1.3.6.1.4.1.2.6.159.201.4.3.1 | current |
| multipleFanFailure NOTIFICATION-TYPE Multiple fans have failed. | 1.3.6.1.4.1.2.6.159.201.4.3.2 | current |
| powerFailureEpow NOTIFICATION-TYPE There was a critical power failure as a result of an EPOW. | 1.3.6.1.4.1.2.6.159.201.4.3.3.1 | current |
| powerFailureFailed NOTIFICATION-TYPE There was a critical power failure as a result of something failing. | 1.3.6.1.4.1.2.6.159.201.4.3.3.2 | current |
| powerFailureRemoved NOTIFICATION-TYPE There was a critical power failure as a result of something removed. | 1.3.6.1.4.1.2.6.159.201.4.3.3.3 | current |
| criticalTamper NOTIFICATION-TYPE Tampering with the system has caused a critical state. | 1.3.6.1.4.1.2.6.159.201.4.3.4 | current |
| criticalTemperatureAmbient NOTIFICATION-TYPE The ambient temperature is in a critical state. | 1.3.6.1.4.1.2.6.159.201.4.3.5.1 | current |
| criticalTemperaturePci NOTIFICATION-TYPE The PCI temperature is in a critical state. | 1.3.6.1.4.1.2.6.159.201.4.3.5.2 | current |
| criticalTemperaturePlanar NOTIFICATION-TYPE The planar temperature is in a critical state. | 1.3.6.1.4.1.2.6.159.201.4.3.5.3 | current |
| criticalTwelveVoltsHigh NOTIFICATION-TYPE A critical state of 12V high has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.1.1 | current |
| criticalTwelveVoltsLow NOTIFICATION-TYPE A critical state of 12V low has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.1.2 | current |
| criticalTwelveVoltsFaultA NOTIFICATION-TYPE A critical state of 12V fault A has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.2 | current |
| criticalTwelveVoltsFaultB NOTIFICATION-TYPE A critical state of 12V fault B has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.3 | current |
| criticalTwelveVoltsFaultC NOTIFICATION-TYPE A critical state of 12V fault C has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.4 | current |
| criticalTwelveVoltsFaultD NOTIFICATION-TYPE A critical state of 12V fault D has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.5 | current |
| criticalOneVoltHigh NOTIFICATION-TYPE A critical state of 1V high has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.6.1 | current |
| criticalOneVoltLow NOTIFICATION-TYPE A critical state of 1V low has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.6.2 | current |
| criticalTwoVoltsHigh NOTIFICATION-TYPE A critical state of 2V high has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.7.1 | current |
| criticalTwoVoltsLow NOTIFICATION-TYPE A critical state of 2V low has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.7.2 | current |
| criticalThreeVoltsHigh NOTIFICATION-TYPE A critical state of 3V high has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.8.1 | current |
| criticalThreeVoltsLow NOTIFICATION-TYPE A critical state of 3V low has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.8.2 | current |
| criticalThreeVoltsPciHigh NOTIFICATION-TYPE A critical state of 3V high has been detected for the PCI. | 1.3.6.1.4.1.2.6.159.201.4.3.6.9.1 | current |
| criticalThreeVoltsPciLow NOTIFICATION-TYPE A critical state of 3V low has been detected for the PCI. | 1.3.6.1.4.1.2.6.159.201.4.3.6.9.2 | current |
| criticalThreeVoltsStandbyHigh NOTIFICATION-TYPE A critical state of 3V standby high has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.10.1 | current |
| criticalThreeVoltsStandbyLow NOTIFICATION-TYPE A critical state of 3V standby low has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.10.2 | current |
| criticalFiveVoltsHigh NOTIFICATION-TYPE A critical state of 5V high has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.11.1 | current |
| criticalFiveVoltsLow NOTIFICATION-TYPE A critical state of 5V low has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.11.2 | current |
| criticalFiveVoltsFaultHigh NOTIFICATION-TYPE A critical state of 5V fault high has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.12.1 | current |
| criticalFiveVoltsFaultLow NOTIFICATION-TYPE A critical state of 5V fault low has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.12.2 | current |
| criticalFiveVoltsPciHigh NOTIFICATION-TYPE A critical state of 5V high has been detected for the PCI. | 1.3.6.1.4.1.2.6.159.201.4.3.6.13.1 | current |
| criticalFiveVoltsPciLow NOTIFICATION-TYPE A critical state of 5V low has been detected for the PCI. | 1.3.6.1.4.1.2.6.159.201.4.3.6.13.2 | current |
| criticalFiveVoltsStandbyHigh NOTIFICATION-TYPE A critical state of 5V standby high has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.14.1 | current |
| criticalFiveVoltsStandbyLow NOTIFICATION-TYPE A critical state of 5V standby low has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.14.2 | current |
| criticalNTwelveVoltsHigh NOTIFICATION-TYPE A critical state of negative 12V high has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.15.1 | current |
| criticalNTwelveVoltsLow NOTIFICATION-TYPE A critical state of negative 12V low has been detected. | 1.3.6.1.4.1.2.6.159.201.4.3.6.15.2 | current |
| voltageRegulatorModuleFailure NOTIFICATION-TYPE The voltage regulator module has failed. | 1.3.6.1.4.1.2.6.159.201.4.3.7 | current |
| deploymentBoot NOTIFICATION-TYPE Deployment has generated a boot event. | 1.3.6.1.4.1.2.6.159.201.4.4.1 | current |
| deploymentLoader NOTIFICATION-TYPE Deployment has generated a loader event. | 1.3.6.1.4.1.2.6.159.201.4.4.2 | current |
| deploymentOs NOTIFICATION-TYPE Deployment has generated an operating system event. | 1.3.6.1.4.1.2.6.159.201.4.4.3 | current |
| deploymentPost NOTIFICATION-TYPE Deployment has generated a POST event. | 1.3.6.1.4.1.2.6.159.201.4.4.4 | current |
| environmentalTemperature NOTIFICATION-TYPE The environmental temperature has changed. | 1.3.6.1.4.1.2.6.159.201.4.5.1 | current |
| environmentalVoltage NOTIFICATION-TYPE The environmental voltage has changed. | 1.3.6.1.4.1.2.6.159.201.4.5.2 | current |
| nonCriticalFanRemoved NOTIFICATION-TYPE A fan has been removed. | 1.3.6.1.4.1.2.6.159.201.4.6.1.1 | current |
| redundantPower NOTIFICATION-TYPE The system is now running on redundant power. | 1.3.6.1.4.1.2.6.159.201.4.6.2 | current |
| singleFanFailure NOTIFICATION-TYPE A single fan has failed. | 1.3.6.1.4.1.2.6.159.201.4.6.3 | current |
| nonCriticalTemperatureAmbient NOTIFICATION-TYPE The ambient temperature is in a non critical state. | 1.3.6.1.4.1.2.6.159.201.4.6.4.1 | current |
| nonCriticalTemperaturePci NOTIFICATION-TYPE The PCI temperature is in a non critical state. | 1.3.6.1.4.1.2.6.159.201.4.6.4.2 | current |
| nonCriticalTemperaturePlanar NOTIFICATION-TYPE The planar temperature is in a non critical state. | 1.3.6.1.4.1.2.6.159.201.4.6.4.3 | current |
| nonCriticalTwelveVoltsHigh NOTIFICATION-TYPE A non-critical state of 12V high has been detected. | 1.3.6.1.4.1.2.6.159.201.4.6.5.1.1 | current |
| nonCriticalTwelveVoltsLow NOTIFICATION-TYPE A non-critical state of 12V low has been detected. | 1.3.6.1.4.1.2.6.159.201.4.6.5.1.2 | current |
| nonCriticalOneVoltHigh NOTIFICATION-TYPE A non-critical state of 1V high has been detected. | 1.3.6.1.4.1.2.6.159.201.4.6.5.2.1 | current |
| nonCriticalOneVoltLow NOTIFICATION-TYPE A non-critical state of 1V low has been detected. | 1.3.6.1.4.1.2.6.159.201.4.6.5.2.2 | current |
| nonCriticalTwoVoltsHigh NOTIFICATION-TYPE A non-critical state of 2V high has been detected. | 1.3.6.1.4.1.2.6.159.201.4.6.5.3.1 | current |
| nonCriticalTwoVoltsLow NOTIFICATION-TYPE A non-critical state of 2V low has been detected. | 1.3.6.1.4.1.2.6.159.201.4.6.5.3.2 | current |
| nonCriticalThreeVoltsHigh NOTIFICATION-TYPE A non-critical state of 3V high has been detected. | 1.3.6.1.4.1.2.6.159.201.4.6.5.4.1 | current |
| nonCriticalThreeVoltsLow NOTIFICATION-TYPE A non-critical state of 3V low has been detected. | 1.3.6.1.4.1.2.6.159.201.4.6.5.4.2 | current |
| nonCriticalThreeVoltsPciHigh NOTIFICATION-TYPE A non-critical state of 3V high has been detected for the PCI. | 1.3.6.1.4.1.2.6.159.201.4.6.5.5.1 | current |
| nonCriticalThreeVoltsPciLow NOTIFICATION-TYPE A non-critical state of 3V low has been detected for the PCI. | 1.3.6.1.4.1.2.6.159.201.4.6.5.5.2 | current |
| nonCriticalThreeVoltsStandbyHigh NOTIFICATION-TYPE A non-critical state of 3V standby high has been detected. | 1.3.6.1.4.1.2.6.159.201.4.6.5.6.1 | current |
| nonCriticalThreeVoltsStandbyLow NOTIFICATION-TYPE A non-critical state of 3V standby low has been detected. | 1.3.6.1.4.1.2.6.159.201.4.6.5.6.2 | current |
| nonCriticalFiveVoltsHigh NOTIFICATION-TYPE A non-critical state of 5V high has been detected. | 1.3.6.1.4.1.2.6.159.201.4.6.5.7.1 | current |
| nonCriticalFiveVoltsLow NOTIFICATION-TYPE A non-critical state of 5V low has been detected. | 1.3.6.1.4.1.2.6.159.201.4.6.5.7.2 | current |
| nonCriticalFiveVoltsPciHigh NOTIFICATION-TYPE A non-critical state of 5V high has been detected for the PCI. | 1.3.6.1.4.1.2.6.159.201.4.6.5.8.1 | current |
| nonCriticalFiveVoltsPciLow NOTIFICATION-TYPE A non-critical state of 5V low has been detected for the PCI. | 1.3.6.1.4.1.2.6.159.201.4.6.5.8.2 | current |
| nonCriticalFiveVoltsStandbyHigh NOTIFICATION-TYPE A non-critical state of 5V standby high has been detected. | 1.3.6.1.4.1.2.6.159.201.4.6.5.9.1 | current |
| nonCriticalFiveVoltsStandbyLow NOTIFICATION-TYPE A non-critical state of 5V standby low has been detected. | 1.3.6.1.4.1.2.6.159.201.4.6.5.9.2 | current |
| nonCriticalNTwelveVoltsHigh NOTIFICATION-TYPE A non-critical state of negative 12V high has been detected. | 1.3.6.1.4.1.2.6.159.201.4.6.5.10.1 | current |
| nonCriticalNTwelveVoltsLow NOTIFICATION-TYPE A non-critical state of negative 12V low has been detected. | 1.3.6.1.4.1.2.6.159.201.4.6.5.10.2 | current |
| scalableNodeModeNullOrUnknown NOTIFICATION-TYPE The scalable node is in a null or unknown mode. | 1.3.6.1.4.1.2.6.159.201.4.7.1.1.1 | current |
| scalableNodeModePrimary NOTIFICATION-TYPE The scalable node is in primary mode. | 1.3.6.1.4.1.2.6.159.201.4.7.1.1.2 | current |
| scalableNodeModeSecondary NOTIFICATION-TYPE The scalable node is in secondary mode. | 1.3.6.1.4.1.2.6.159.201.4.7.1.1.3 | current |
| scalableNodeModeStandalone NOTIFICATION-TYPE The scalable node is now in standalone mode. | 1.3.6.1.4.1.2.6.159.201.4.7.1.1.4 | current |
| primary NOTIFICATION-TYPE The scalable node is now in standalone primary mode. | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.1 | current |
| resetPrimary NOTIFICATION-TYPE The scalable node is now in standalone primary reset mode. | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.2.1 | current |
| resetSecondary NOTIFICATION-TYPE The scalable node is now in standalone primary secondary mode. | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.2.2 | current |
| secondary NOTIFICATION-TYPE The scalable node is now in standalone secondary mode. | 1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.3 | current |
| scalablePartitionAlert NOTIFICATION-TYPE The scalabel partition has generated an alert. | 1.3.6.1.4.1.2.6.159.201.4.7.2.1 | current |
| scalablePartitionNullOrUnknown NOTIFICATION-TYPE The scalable partition state is 'null or unknown'. | 1.3.6.1.4.1.2.6.159.201.4.7.2.2.1 | current |
| scalablePartitionPoweredOff NOTIFICATION-TYPE The scalable partition state is 'powered off'. | 1.3.6.1.4.1.2.6.159.201.4.7.2.2.2 | current |
| scalablePartitionPoweringOn NOTIFICATION-TYPE The scalable partition state is 'powering on'. | 1.3.6.1.4.1.2.6.159.201.4.7.2.2.3 | current |
| scalablePartitionResetting NOTIFICATION-TYPE The scalable partition state is 'resetting'. | 1.3.6.1.4.1.2.6.159.201.4.7.2.2.4 | current |
| scalablePartitionShuttingDown NOTIFICATION-TYPE The scalable partition state is 'shutting down'. | 1.3.6.1.4.1.2.6.159.201.4.7.2.2.5 | current |
| bootFailure NOTIFICATION-TYPE The system indicated a boot failure. | 1.3.6.1.4.1.2.6.159.201.4.8.1 | current |
| fuelGaugeLowFuel NOTIFICATION-TYPE The fuel gauge indicates low fuel. | 1.3.6.1.4.1.2.6.159.201.4.8.2.1 | current |
| fuelGaugeNotRedundant NOTIFICATION-TYPE The fuel gauge indicates not redundant. | 1.3.6.1.4.1.2.6.159.201.4.8.2.2 | current |
| fuelGaugeOverCurrent NOTIFICATION-TYPE The fuel gauge indicates over current. | 1.3.6.1.4.1.2.6.159.201.4.8.2.3 | current |
| systemLoaderTimeout NOTIFICATION-TYPE The system loader has timed out. | 1.3.6.1.4.1.2.6.159.201.4.8.3 | current |
| systemOsTimeout NOTIFICATION-TYPE The operating system has timed out. | 1.3.6.1.4.1.2.6.159.201.4.8.4 | current |
| fanSystemPfa NOTIFICATION-TYPE The fan system has generated a PFA. | 1.3.6.1.4.1.2.6.159.201.4.8.5.1 | current |
| systemPostTimeout NOTIFICATION-TYPE The POST has timed out. | 1.3.6.1.4.1.2.6.159.201.4.8.6 | current |
| systemPowerOff NOTIFICATION-TYPE The sytsem has powered off. | 1.3.6.1.4.1.2.6.159.201.4.8.7 | current |
| systemPowerOn NOTIFICATION-TYPE The sytsem has powered on. | 1.3.6.1.4.1.2.6.159.201.4.8.8 | current |
| systemRedundantPower NOTIFICATION-TYPE The system is running on redundant power. | 1.3.6.1.4.1.2.6.159.201.4.8.9 | current |
| systemTamper NOTIFICATION-TYPE The system has been tampered with. | 1.3.6.1.4.1.2.6.159.201.4.8.10 | current |
| unknown NOTIFICATION-TYPE The system is in an unknown state. | 1.3.6.1.4.1.2.6.159.201.4.9 | current |
| sensorCaseIntrusion NOTIFICATION-TYPE A sensor has detected a case intrusion. | 1.3.6.1.4.1.2.6.159.201.5.2.1.1 | current |
| sensorCurrent NOTIFICATION-TYPE A sensor has detected a current change. | 1.3.6.1.4.1.2.6.159.201.5.2.1.2 | current |
| sensorFan NOTIFICATION-TYPE A sensor has detected a fan change. | 1.3.6.1.4.1.2.6.159.201.5.2.1.3 | current |
| sensorPowerSupply NOTIFICATION-TYPE A sensor has detected a power supply change. | 1.3.6.1.4.1.2.6.159.201.5.2.1.4 | current |
| sensorTemperature NOTIFICATION-TYPE A sensor has detected a temperature change. | 1.3.6.1.4.1.2.6.159.201.5.2.1.5 | current |
| sensorVoltage NOTIFICATION-TYPE A sensor has detected a voltage change. | 1.3.6.1.4.1.2.6.159.201.5.2.1.6 | current |
| progress NOTIFICATION-TYPE The progress of the BIOS has changed. | 1.3.6.1.4.1.2.6.159.201.5.3.1.1 | current |
| cableInterconnect NOTIFICATION-TYPE The cable/interconnect hardware has generated an event. | 1.3.6.1.4.1.2.6.159.201.5.4.1 | current |
| drivebay NOTIFICATION-TYPE The monitor drivebay hardware has generated an event. | 1.3.6.1.4.1.2.6.159.201.5.4.2 | current |
| moduleBoard NOTIFICATION-TYPE The monitor module/board hardware has generated an event. | 1.3.6.1.4.1.2.6.159.201.5.4.3 | current |
| monitorAsicIc NOTIFICATION-TYPE The monitor ASIC/IC hardware has generated an event. | 1.3.6.1.4.1.2.6.159.201.5.4.4 | current |
| network NOTIFICATION-TYPE The network hardware has generated an event. | 1.3.6.1.4.1.2.6.159.201.5.4.5 | current |
| watchdog1 NOTIFICATION-TYPE The hardware has generated a watchdog 1 event. | 1.3.6.1.4.1.2.6.159.201.5.4.6 | current |
| watchdog2 NOTIFICATION-TYPE The hardware has generated a watchdog 2 event. | 1.3.6.1.4.1.2.6.159.201.5.4.7 | current |
| petFamilySystemOsBoot NOTIFICATION-TYPE The operating system on the host has booted. | 1.3.6.1.4.1.2.6.159.201.5.5.1.1 | current |
| heartbeat NOTIFICATION-TYPE The operating system has generated a heartbeat event. | 1.3.6.1.4.1.2.6.159.201.5.5.1.2.1 | current |
| vendorUnsupported NOTIFICATION-TYPE The vendor for this physical drive is unsupported. | 1.3.6.1.4.1.2.6.159.201.6.1.1.1 | current |
| notFound NOTIFICATION-TYPE No controllers were found in this system. | 1.3.6.1.4.1.2.6.159.201.6.1.2.1 | current |
Conformance
| Name | OID | Status |
|---|---|---|
| directorTrapsGroup OBJECT-GROUP The objects group for objects defined in this module. | 1.3.6.1.4.1.2.6.159.201.100.1.1 | current |
| directorNotificationsGroup NOTIFICATION-GROUP The notification group for notifications defined in this module. | 1.3.6.1.4.1.2.6.159.201.100.1.2 | current |
| directorTrapsCompliance MODULE-COMPLIANCE The compliance statement for this module. | 1.3.6.1.4.1.2.6.159.201.100.2.1 | current |